MIBs Depot

CTRON-POWER-SUPPLY-MIB

Registered at
1.3.6.1.4.1.52.4.1.1.7.1
1.3.6.1.4.1.52.4.1.1.7.2
1.3.6.1.4.1.52.4.1.1.7.3
1.3.6.1.4.1.52.4.1.1.7.4
1.3.6.1.4.1.52.4.1.1.7.5
Namespace
enterasys
Source file
CTRON-POWER-SUPPLY-MIB
Digest
sha256:beb8b5d9f57cda46940feab9ab78aa134ced6b670e7b71d369faff3a4d64241d

Imports

FromSymbols
CTRON-MIB-NAMESctps
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTRON-MIB-NAMES
CTRON-OIDS
CTRON-POWER-SUPPLY-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
chPower
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.1.7.1
chPowerOperationalStatus
OBJECT-TYPE
This object reflects the overall status of the chassis's power supply in terms of how the power is being delivered to the chassis.
1.3.6.1.4.1.52.4.1.1.7.1.1INTEGER {powerAC(1), powerACRedundant(2), powerDC(3), powerDCRedundant(4), battery(5)}read-onlymandatory
chPowerMainVoltageStatus
OBJECT-TYPE
This object reflects the state of the main voltage rail within the chassis. The power on this rail may be delivered by AC supplies, DC supplies or battery supplies.
1.3.6.1.4.1.52.4.1.1.7.1.2INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVoltage(4)}read-onlymandatory
chPowerMainVoltage
OBJECT-TYPE
The voltage of the chassis's main voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 40 volts to 60 volts DC. The value of this object is the actual voltage * 10.
1.3.6.1.4.1.52.4.1.1.7.1.3INTEGERread-onlymandatory
chPowerTotalSupply
OBJECT-TYPE
The total power being supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.4INTEGERread-onlymandatory
chPowerTotalLoad
OBJECT-TYPE
The total load being presented by the chassis to the chassis's power supplies. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.5INTEGERread-onlymandatory
chPowerMaxSupply
OBJECT-TYPE
The maximum power that could de supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.6INTEGERread-onlymandatory
chPowerMaxLoad
OBJECT-TYPE
The maximum load that could be presented by the chassis to the chassis's power supplies. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.7INTEGERread-onlymandatory
chPowerTable
OBJECT-TYPE
A list of power lines or busses on the chassis's backplane.
1.3.6.1.4.1.52.4.1.1.7.1.8not-accessiblemandatory
chPowerEntry
OBJECT-TYPE
A slot entry containing objects for a particular module and associated power line.
1.3.6.1.4.1.52.4.1.1.7.1.8.1not-accessiblemandatory
chPowerLineID
OBJECT-TYPE
A unique value used to identify a particular power line on the chassis's backplane.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.1INTEGERread-onlymandatory
chPowerLineType
OBJECT-TYPE
The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.2OBJECT IDENTIFIERread-onlymandatory
chPowerLineTotalSupply
OBJECT-TYPE
The total power being supplied by the chassis's power supplies to the chassis on this power line. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.3INTEGERread-onlymandatory
chPowerLineTotalLoad
OBJECT-TYPE
The total load being presented by the chassis to the chassis's power supplies on this power line. This value will be zero if unknown The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.4INTEGERread-onlymandatory
chPowerLineMaxSupply
OBJECT-TYPE
The maximum power that could de supplied by the chassis's power supplies to the chassison this power line. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.5INTEGERread-onlymandatory
chPowerLineMaxLoad
OBJECT-TYPE
The maximum load that could be presented by the chassis to the chassis's power supplies on this power line. The value of this object is the actual watts.
1.3.6.1.4.1.52.4.1.1.7.1.8.1.6INTEGERread-onlymandatory
chPowerDiagVoltageStatus
OBJECT-TYPE
This object reflects the state of the diag voltage rail within the chassis.
1.3.6.1.4.1.52.4.1.1.7.1.9INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVoltage(4)}read-onlymandatory
chPowerDiagVoltage
OBJECT-TYPE
The voltage of the chassis's diag voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 4.75 volts to 5.25 volts DC. The value of this object is the actual voltage * 10.
1.3.6.1.4.1.52.4.1.1.7.1.10INTEGERread-onlymandatory
boardPower
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.1.7.2
boardPowerSlotStatusTable
OBJECT-TYPE
A list of networking modules installed in this chassis.
1.3.6.1.4.1.52.4.1.1.7.2.1not-accessiblemandatory
boardPowerSlotStatusEntry
OBJECT-TYPE
A slot entry containing objects for a particular module.
1.3.6.1.4.1.52.4.1.1.7.2.1.1not-accessiblemandatory
boardPowerSlotStatusID
OBJECT-TYPE
The slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.1INTEGERread-onlymandatory
boardPowerOperationalStatus
OBJECT-TYPE
This object reflects the status of the module's DC-DC converter power supply.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.2INTEGER {powerOn(1), powerOff(2), reset(3), overVoltage(4), underVoltage(5), overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8), remotePowerOff(9), powerConservationShutdown(10), frontPanelPowerOff(11)}read-onlymandatory
boardPowerAdminStatus
OBJECT-TYPE
This object controls the operation of the module's DC-DC power supply. If the value 3 is written to this object then the value of the object will be set to 1 after the reset is performed.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.3INTEGER {powerOn(1), powerOff(2), reset(3)}read-writemandatory
boardPowerLocalAdminStatus
OBJECT-TYPE
This object controls the operation of the module's front panel button. In local mode this button may be used to locally control the operation of the DC-DC converter, i.e. power on, power off and reset. In secure mode a request the state of the front panel button is reflected in the object boardPowerOperationalStatus. In secure mode the front panel button has no effect locally.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.4INTEGER {localMode(1), secureMode(2)}read-writemandatory
boardPowerLocalStatus
OBJECT-TYPE
This object reflects the state of the module's front panel button.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.5INTEGER {resetRequest(1), powerDownRequest(2), powerOnRequest(3), normal(4)}read-onlymandatory
boardPowerShutdownAdmin
OBJECT-TYPE
This object controls whether or not the module should auto power down due to an fault condition.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.6INTEGER {enabled(1), disabled(2)}read-writemandatory
boardPowerPriority
OBJECT-TYPE
The module's power-up and power down priority. This is a value of 1 to 14 and is used to decide which modules are allowed to power on in the event that power demand of the chassis is greater than the total power supply. The default value is 14, highest priority. When two modules have equal priority then the module in the lowest slot wins.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.7INTEGER (1..14)read-writemandatory
boardPowerMaxInputPower
OBJECT-TYPE
The maximum input power that this module is allowed to consume. The value of this object is actual watts.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.8INTEGERread-onlymandatory
boardPowerManagement
OBJECT-TYPE
Module power management status.
1.3.6.1.4.1.52.4.1.1.7.2.1.1.9INTEGER {disabled(1), enabled(2), not-supported(7)}read-writemandatory
boardPowerSlotTable
OBJECT-TYPE
A list of networking modules and associated power lines installed in this chassis.
1.3.6.1.4.1.52.4.1.1.7.2.2not-accessiblemandatory
boardPowerSlotEntry
OBJECT-TYPE
A slot entry containing objects for a particular module and associated power line.
1.3.6.1.4.1.52.4.1.1.7.2.2.1not-accessiblemandatory
boardPowerSlotID
OBJECT-TYPE
The slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.1INTEGERread-onlymandatory
boardPowerID
OBJECT-TYPE
A unique value used to identify a particular power line.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.2INTEGERread-onlymandatory
boardPowerType
OBJECT-TYPE
The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.3OBJECT IDENTIFIERread-onlymandatory
boardPowerStatus
OBJECT-TYPE
This object reflects the status of this power line.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.4INTEGER {powerOK(1), powerOff(2), overCurrent(3), overVoltage(4), underVoltage(5)}read-onlymandatory
boardPowerVoltage
OBJECT-TYPE
The voltage reading for the power line. The value of this object is actual voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.5INTEGERread-onlymandatory
boardPowerCurrent
OBJECT-TYPE
The current reading for the power line. The value of this object is the actual amperage * 100. If this reading is not implemented then value will be zero.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.6INTEGERread-onlymandatory
boardPowerMaxVoltage
OBJECT-TYPE
The maximum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an overvolatge condition. The value of this object is in voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.7INTEGERread-onlymandatory
boardPowerMinVoltage
OBJECT-TYPE
The minimum voltage for this power line. If the voltage reading for this power line is less than this value then the power line is considered to be in an undervolatge condition. The value of this object is voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.8INTEGERread-onlymandatory
boardPowerMaxPower
OBJECT-TYPE
The maximum power for this power line. If the power calculated for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is in watts.
1.3.6.1.4.1.52.4.1.1.7.2.2.1.9INTEGERread-onlymandatory
psPower
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.1.7.3
psPowerSlotStatusTable
OBJECT-TYPE
A list of AC & DC power supplies installed in this chassis.
1.3.6.1.4.1.52.4.1.1.7.3.1not-accessiblemandatory
psPowerSlotStatusEntry
OBJECT-TYPE
A slot entry containing objects for a particular power supply.
1.3.6.1.4.1.52.4.1.1.7.3.1.1not-accessiblemandatory
psPowerSlotStatusID
OBJECT-TYPE
The slot number of a chassis slot in which this AC power supply is installed. This object is similiar to chSlotID in the Chassis MIB.
1.3.6.1.4.1.52.4.1.1.7.3.1.1.1INTEGERread-onlymandatory
psPowerOperationalStatus
OBJECT-TYPE
This object reflects the status of the module's DC-DC converter power supply.
1.3.6.1.4.1.52.4.1.1.7.3.1.1.2INTEGER {powerOn(1), powerOff(2), reset(3), overVoltage(4), underVoltage(5), overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8), remotePowerOff(9)}read-onlymandatory
psPowerAdminStatus
OBJECT-TYPE
This object controls the operation of power supply.
1.3.6.1.4.1.52.4.1.1.7.3.1.1.3INTEGER {powerOn(1), powerOff(2)}read-writemandatory
psPowerMaxOutputPower
OBJECT-TYPE
The maximum power that this power supply is allowed to ouput. The value of this object is watts.
1.3.6.1.4.1.52.4.1.1.7.3.1.1.4INTEGERread-onlymandatory
psPowerSlotTable
OBJECT-TYPE
A list of power supplies and associated power lines installed in this chassis.
1.3.6.1.4.1.52.4.1.1.7.3.2not-accessiblemandatory
psPowerSlotEntry
OBJECT-TYPE
A slot entry containing objects for a particular power line on a particular power supply.
1.3.6.1.4.1.52.4.1.1.7.3.2.1not-accessiblemandatory
psPowerSlotID
OBJECT-TYPE
The slot number of a chassis slot in which this Power supply is installed. This object is similiar to chSlotID in the Chassis MIB.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.1INTEGERread-onlymandatory
psPowerID
OBJECT-TYPE
A unique value used to identify a particular power line.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.2INTEGERread-onlymandatory
psPowerType
OBJECT-TYPE
The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.3OBJECT IDENTIFIERread-onlymandatory
psPowerStatus
OBJECT-TYPE
This object reflects the status of the power line.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.4INTEGER {powerOK(1), powerOff(2), overCurrent(3), overVoltage(4), underVoltage(5)}read-onlymandatory
psPowerAdmin
OBJECT-TYPE
This object controls the operation of power supply.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.5INTEGER {powerOn(1), powerOff(2)}read-writemandatory
psPowerVoltage
OBJECT-TYPE
The voltage reading for the power line. The value of this object is the actual voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.6INTEGERread-onlymandatory
psPowerCurrent
OBJECT-TYPE
The current reading for the power line. The value of this object is amperage * 100. If this reading is not implemented then value will be zero.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.7INTEGERread-onlymandatory
psPowerLineFrequency
OBJECT-TYPE
The line frequency for the power line. The value of this object is the actual frequency in Hertz * 10. If this reading is not implemented then value will be zero.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.8INTEGERread-onlymandatory
psPowerMaxVoltage
OBJECT-TYPE
The maximum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.9INTEGERread-onlymandatory
psPowerMinVoltage
OBJECT-TYPE
The minimum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.10INTEGERread-onlymandatory
psPowerMaxPower
OBJECT-TYPE
The maximum power for this power line. If the power calculated for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is watts.
1.3.6.1.4.1.52.4.1.1.7.3.2.1.11INTEGERread-onlymandatory
bbuPower
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.1.7.4
termPower
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.1.7.5
termPowerStatus
OBJECT-TYPE
This object reflects the status of the chassis's termination voltage rail.
1.3.6.1.4.1.52.4.1.1.7.5.1INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVolatge(4), overPower(5)}read-onlymandatory
termPowerVoltage
OBJECT-TYPE
The voltage of the chassis's termination voltage rail. This rail carries power to INB terminator cards in the chassis. It has an allowalble range of 3.3 Volt + or - 5%.The value of this object is voltage * 100.
1.3.6.1.4.1.52.4.1.1.7.5.2INTEGERread-onlymandatory
termPowerCurrent
OBJECT-TYPE
The current on the chassis's termination voltage rail. The value of this object is the actual amperage * 100. If this reading is not implemented then the value will be zero.
1.3.6.1.4.1.52.4.1.1.7.5.3INTEGERread-onlymandatory
termPowerModule1Status
OBJECT-TYPE
This object reflects the state of the INB termination module number 1. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition.
1.3.6.1.4.1.52.4.1.1.7.5.4INTEGER {normal(1), iNBaFault(2), iNBbFault(3), fault(4), termModuleNotInstalled(5), unknown(6)}read-onlymandatory
termPowerModule2Status
OBJECT-TYPE
This object reflects the state of the INB termination module number 2. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition.
1.3.6.1.4.1.52.4.1.1.7.5.5INTEGER {normal(1), iNBaFault(2), iNBbFault(3), fault(4), termModuleNotInstalled(5), unknown(6)}read-onlymandatory