CTRON-POWER-SUPPLY-MIB
- Registered at
- 1.3.6.1.4.1.52.4.1.1.7.11.3.6.1.4.1.52.4.1.1.7.21.3.6.1.4.1.52.4.1.1.7.31.3.6.1.4.1.52.4.1.1.7.41.3.6.1.4.1.52.4.1.1.7.5
- Namespace
- enterasys
- Source file
CTRON-POWER-SUPPLY-MIB- Digest
sha256:beb8b5d9f57cda46940feab9ab78aa134ced6b670e7b71d369faff3a4d64241d
Imports
| From | Symbols |
|---|---|
| CTRON-MIB-NAMES | ctps |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CTRON-MIB-NAMES CTRON-OIDS CTRON-POWER-SUPPLY-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| chPower OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.1.7.1 | |||
| chPowerOperationalStatus OBJECT-TYPE This object reflects the overall status of the chassis's power supply in terms of how the power is being delivered to the chassis. | 1.3.6.1.4.1.52.4.1.1.7.1.1 | INTEGER {powerAC(1), powerACRedundant(2), powerDC(3), powerDCRedundant(4), battery(5)} | read-only | mandatory |
| chPowerMainVoltageStatus OBJECT-TYPE This object reflects the state of the main voltage rail within the chassis. The power on this rail may be delivered by AC supplies, DC supplies or battery supplies. | 1.3.6.1.4.1.52.4.1.1.7.1.2 | INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVoltage(4)} | read-only | mandatory |
| chPowerMainVoltage OBJECT-TYPE The voltage of the chassis's main voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 40 volts to 60 volts DC. The value of this object is the actual voltage * 10. | 1.3.6.1.4.1.52.4.1.1.7.1.3 | INTEGER | read-only | mandatory |
| chPowerTotalSupply OBJECT-TYPE The total power being supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.4 | INTEGER | read-only | mandatory |
| chPowerTotalLoad OBJECT-TYPE The total load being presented by the chassis to the chassis's power supplies. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.5 | INTEGER | read-only | mandatory |
| chPowerMaxSupply OBJECT-TYPE The maximum power that could de supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.6 | INTEGER | read-only | mandatory |
| chPowerMaxLoad OBJECT-TYPE The maximum load that could be presented by the chassis to the chassis's power supplies. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.7 | INTEGER | read-only | mandatory |
| chPowerTable OBJECT-TYPE A list of power lines or busses on the chassis's backplane. | 1.3.6.1.4.1.52.4.1.1.7.1.8 | not-accessible | mandatory | |
| chPowerEntry OBJECT-TYPE A slot entry containing objects for a particular module and associated power line. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1 | not-accessible | mandatory | |
| chPowerLineID OBJECT-TYPE A unique value used to identify a particular power line on the chassis's backplane. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.1 | INTEGER | read-only | mandatory |
| chPowerLineType OBJECT-TYPE The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.2 | OBJECT IDENTIFIER | read-only | mandatory |
| chPowerLineTotalSupply OBJECT-TYPE The total power being supplied by the chassis's power supplies to the chassis on this power line. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.3 | INTEGER | read-only | mandatory |
| chPowerLineTotalLoad OBJECT-TYPE The total load being presented by the chassis to the chassis's power supplies on this power line. This value will be zero if unknown The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.4 | INTEGER | read-only | mandatory |
| chPowerLineMaxSupply OBJECT-TYPE The maximum power that could de supplied by the chassis's power supplies to the chassison this power line. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.5 | INTEGER | read-only | mandatory |
| chPowerLineMaxLoad OBJECT-TYPE The maximum load that could be presented by the chassis to the chassis's power supplies on this power line. The value of this object is the actual watts. | 1.3.6.1.4.1.52.4.1.1.7.1.8.1.6 | INTEGER | read-only | mandatory |
| chPowerDiagVoltageStatus OBJECT-TYPE This object reflects the state of the diag voltage rail within the chassis. | 1.3.6.1.4.1.52.4.1.1.7.1.9 | INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVoltage(4)} | read-only | mandatory |
| chPowerDiagVoltage OBJECT-TYPE The voltage of the chassis's diag voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 4.75 volts to 5.25 volts DC. The value of this object is the actual voltage * 10. | 1.3.6.1.4.1.52.4.1.1.7.1.10 | INTEGER | read-only | mandatory |
| boardPower OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.1.7.2 | |||
| boardPowerSlotStatusTable OBJECT-TYPE A list of networking modules installed in this chassis. | 1.3.6.1.4.1.52.4.1.1.7.2.1 | not-accessible | mandatory | |
| boardPowerSlotStatusEntry OBJECT-TYPE A slot entry containing objects for a particular module. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1 | not-accessible | mandatory | |
| boardPowerSlotStatusID OBJECT-TYPE The slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.1 | INTEGER | read-only | mandatory |
| boardPowerOperationalStatus OBJECT-TYPE This object reflects the status of the module's DC-DC converter power supply. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.2 | INTEGER {powerOn(1), powerOff(2), reset(3), overVoltage(4), underVoltage(5), overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8), remotePowerOff(9), powerConservationShutdown(10), frontPanelPowerOff(11)} | read-only | mandatory |
| boardPowerAdminStatus OBJECT-TYPE This object controls the operation of the module's DC-DC power supply. If the value 3 is written to this object then the value of the object will be set to 1 after the reset is performed. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.3 | INTEGER {powerOn(1), powerOff(2), reset(3)} | read-write | mandatory |
| boardPowerLocalAdminStatus OBJECT-TYPE This object controls the operation of the module's front panel button. In local mode this button may be used to locally control the operation of the DC-DC converter, i.e. power on, power off and reset. In secure mode a request the state of the front panel button is reflected in the object boardPowerOperationalStatus. In secure mode the front panel button has no effect locally. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.4 | INTEGER {localMode(1), secureMode(2)} | read-write | mandatory |
| boardPowerLocalStatus OBJECT-TYPE This object reflects the state of the module's front panel button. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.5 | INTEGER {resetRequest(1), powerDownRequest(2), powerOnRequest(3), normal(4)} | read-only | mandatory |
| boardPowerShutdownAdmin OBJECT-TYPE This object controls whether or not the module should auto power down due to an fault condition. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.6 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| boardPowerPriority OBJECT-TYPE The module's power-up and power down priority. This is a value of 1 to 14 and is used to decide which modules are allowed to power on in the event that power demand of the chassis is greater than the total power supply. The default value is 14, highest priority. When two modules have equal priority then the module in the lowest slot wins. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.7 | INTEGER (1..14) | read-write | mandatory |
| boardPowerMaxInputPower OBJECT-TYPE The maximum input power that this module is allowed to consume. The value of this object is actual watts. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.8 | INTEGER | read-only | mandatory |
| boardPowerManagement OBJECT-TYPE Module power management status. | 1.3.6.1.4.1.52.4.1.1.7.2.1.1.9 | INTEGER {disabled(1), enabled(2), not-supported(7)} | read-write | mandatory |
| boardPowerSlotTable OBJECT-TYPE A list of networking modules and associated power lines installed in this chassis. | 1.3.6.1.4.1.52.4.1.1.7.2.2 | not-accessible | mandatory | |
| boardPowerSlotEntry OBJECT-TYPE A slot entry containing objects for a particular module and associated power line. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1 | not-accessible | mandatory | |
| boardPowerSlotID OBJECT-TYPE The slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 | INTEGER | read-only | mandatory |
| boardPowerID OBJECT-TYPE A unique value used to identify a particular power line. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 | INTEGER | read-only | mandatory |
| boardPowerType OBJECT-TYPE The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.3 | OBJECT IDENTIFIER | read-only | mandatory |
| boardPowerStatus OBJECT-TYPE This object reflects the status of this power line. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.4 | INTEGER {powerOK(1), powerOff(2), overCurrent(3), overVoltage(4), underVoltage(5)} | read-only | mandatory |
| boardPowerVoltage OBJECT-TYPE The voltage reading for the power line. The value of this object is actual voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.5 | INTEGER | read-only | mandatory |
| boardPowerCurrent OBJECT-TYPE The current reading for the power line. The value of this object is the actual amperage * 100. If this reading is not implemented then value will be zero. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.6 | INTEGER | read-only | mandatory |
| boardPowerMaxVoltage OBJECT-TYPE The maximum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an overvolatge condition. The value of this object is in voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.7 | INTEGER | read-only | mandatory |
| boardPowerMinVoltage OBJECT-TYPE The minimum voltage for this power line. If the voltage reading for this power line is less than this value then the power line is considered to be in an undervolatge condition. The value of this object is voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.8 | INTEGER | read-only | mandatory |
| boardPowerMaxPower OBJECT-TYPE The maximum power for this power line. If the power calculated for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is in watts. | 1.3.6.1.4.1.52.4.1.1.7.2.2.1.9 | INTEGER | read-only | mandatory |
| psPower OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.1.7.3 | |||
| psPowerSlotStatusTable OBJECT-TYPE A list of AC & DC power supplies installed in this chassis. | 1.3.6.1.4.1.52.4.1.1.7.3.1 | not-accessible | mandatory | |
| psPowerSlotStatusEntry OBJECT-TYPE A slot entry containing objects for a particular power supply. | 1.3.6.1.4.1.52.4.1.1.7.3.1.1 | not-accessible | mandatory | |
| psPowerSlotStatusID OBJECT-TYPE The slot number of a chassis slot in which this AC power supply is installed. This object is similiar to chSlotID in the Chassis MIB. | 1.3.6.1.4.1.52.4.1.1.7.3.1.1.1 | INTEGER | read-only | mandatory |
| psPowerOperationalStatus OBJECT-TYPE This object reflects the status of the module's DC-DC converter power supply. | 1.3.6.1.4.1.52.4.1.1.7.3.1.1.2 | INTEGER {powerOn(1), powerOff(2), reset(3), overVoltage(4), underVoltage(5), overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8), remotePowerOff(9)} | read-only | mandatory |
| psPowerAdminStatus OBJECT-TYPE This object controls the operation of power supply. | 1.3.6.1.4.1.52.4.1.1.7.3.1.1.3 | INTEGER {powerOn(1), powerOff(2)} | read-write | mandatory |
| psPowerMaxOutputPower OBJECT-TYPE The maximum power that this power supply is allowed to ouput. The value of this object is watts. | 1.3.6.1.4.1.52.4.1.1.7.3.1.1.4 | INTEGER | read-only | mandatory |
| psPowerSlotTable OBJECT-TYPE A list of power supplies and associated power lines installed in this chassis. | 1.3.6.1.4.1.52.4.1.1.7.3.2 | not-accessible | mandatory | |
| psPowerSlotEntry OBJECT-TYPE A slot entry containing objects for a particular power line on a particular power supply. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1 | not-accessible | mandatory | |
| psPowerSlotID OBJECT-TYPE The slot number of a chassis slot in which this Power supply is installed. This object is similiar to chSlotID in the Chassis MIB. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.1 | INTEGER | read-only | mandatory |
| psPowerID OBJECT-TYPE A unique value used to identify a particular power line. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.2 | INTEGER | read-only | mandatory |
| psPowerType OBJECT-TYPE The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.3 | OBJECT IDENTIFIER | read-only | mandatory |
| psPowerStatus OBJECT-TYPE This object reflects the status of the power line. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.4 | INTEGER {powerOK(1), powerOff(2), overCurrent(3), overVoltage(4), underVoltage(5)} | read-only | mandatory |
| psPowerAdmin OBJECT-TYPE This object controls the operation of power supply. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.5 | INTEGER {powerOn(1), powerOff(2)} | read-write | mandatory |
| psPowerVoltage OBJECT-TYPE The voltage reading for the power line. The value of this object is the actual voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.6 | INTEGER | read-only | mandatory |
| psPowerCurrent OBJECT-TYPE The current reading for the power line. The value of this object is amperage * 100. If this reading is not implemented then value will be zero. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.7 | INTEGER | read-only | mandatory |
| psPowerLineFrequency OBJECT-TYPE The line frequency for the power line. The value of this object is the actual frequency in Hertz * 10. If this reading is not implemented then value will be zero. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.8 | INTEGER | read-only | mandatory |
| psPowerMaxVoltage OBJECT-TYPE The maximum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.9 | INTEGER | read-only | mandatory |
| psPowerMinVoltage OBJECT-TYPE The minimum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.10 | INTEGER | read-only | mandatory |
| psPowerMaxPower OBJECT-TYPE The maximum power for this power line. If the power calculated for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is watts. | 1.3.6.1.4.1.52.4.1.1.7.3.2.1.11 | INTEGER | read-only | mandatory |
| bbuPower OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.1.7.4 | |||
| termPower OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.1.1.7.5 | |||
| termPowerStatus OBJECT-TYPE This object reflects the status of the chassis's termination voltage rail. | 1.3.6.1.4.1.52.4.1.1.7.5.1 | INTEGER {powerOK(1), overCurrent(2), overVoltage(3), underVolatge(4), overPower(5)} | read-only | mandatory |
| termPowerVoltage OBJECT-TYPE The voltage of the chassis's termination voltage rail. This rail carries power to INB terminator cards in the chassis. It has an allowalble range of 3.3 Volt + or - 5%.The value of this object is voltage * 100. | 1.3.6.1.4.1.52.4.1.1.7.5.2 | INTEGER | read-only | mandatory |
| termPowerCurrent OBJECT-TYPE The current on the chassis's termination voltage rail. The value of this object is the actual amperage * 100. If this reading is not implemented then the value will be zero. | 1.3.6.1.4.1.52.4.1.1.7.5.3 | INTEGER | read-only | mandatory |
| termPowerModule1Status OBJECT-TYPE This object reflects the state of the INB termination module number 1. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition. | 1.3.6.1.4.1.52.4.1.1.7.5.4 | INTEGER {normal(1), iNBaFault(2), iNBbFault(3), fault(4), termModuleNotInstalled(5), unknown(6)} | read-only | mandatory |
| termPowerModule2Status OBJECT-TYPE This object reflects the state of the INB termination module number 2. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition. | 1.3.6.1.4.1.52.4.1.1.7.5.5 | INTEGER {normal(1), iNBaFault(2), iNBbFault(3), fault(4), termModuleNotInstalled(5), unknown(6)} | read-only | mandatory |