MIBs Depot

CTRON-FDDI-FNB-MIB

Registered at
1.3.6.1.4.1.52.4.1.2.5.1.1
1.3.6.1.4.1.52.4.1.2.5.1.2
1.3.6.1.4.1.52.4.1.2.5.1.3
1.3.6.1.4.1.52.4.1.2.5.1.4
Namespace
enterasys
Source file
CTRON-FDDI-FNB-MIB
Digest
sha256:7a2707783968898d11d49e673ad04c19f002fdbab8617756c4196d2825f54ae1

Imports

FromSymbols
CTRON-MIB-NAMESctFDDIFnb
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTRON-FDDI-FNB-MIB
CTRON-MIB-NAMES
CTRON-OIDS
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ctFDDIResource
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.5.1.1
ctFDDIResourceTable
OBJECT-TYPE
This table specifies the physical resources associated with the FNB and general FNB operation for a particular module in a particular slot.
1.3.6.1.4.1.52.4.1.2.5.1.1.1not-accessiblemandatory
ctFDDIResourceEntry
OBJECT-TYPE
Defines a specific physical resource entry
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1not-accessiblemandatory
ctFDDIResourceSlotID
OBJECT-TYPE
A specific instance of a slot as defined by chSlotID as defined in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.1INTEGER (1..255)read-onlymandatory
ctFDDIResourceID
OBJECT-TYPE
A unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.2INTEGERread-onlymandatory
ctFDDIResourceType
OBJECT-TYPE
Defines the type of resource. This is the same value as chResourceType in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.3OBJECT IDENTIFIERread-onlymandatory
ctFDDIResourceNumbInstance
OBJECT-TYPE
This object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of a resource from the top to the bottom, then the numbering will start from the left side and proceed top-to-bottom in each column. For instance, the first FNB ring will be instance 1 (top in the chassis) while the second FNB ring is instance 2 (below FNB 1 in the backplane).
1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.4INTEGERread-onlymandatory
ctFDDINonMux
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.5.1.2
ctFDDINonMuxCapTable
OBJECT-TYPE
This table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis.
1.3.6.1.4.1.52.4.1.2.5.1.2.1not-accessiblemandatory
ctFDDINonMuxCapEntry
OBJECT-TYPE
Describes a particular capability/configuration entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1not-accessiblemandatory
ctFDDINMSlot
OBJECT-TYPE
The slot within the chassis for which this configuration information is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.1INTEGER (1..256)read-onlymandatory
ctFDDINMConfigID
OBJECT-TYPE
The instance of a particular configuration.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.2INTEGERread-onlymandatory
ctFDDINMConfig
OBJECT-TYPE
This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string, using a specified format for interpretation. The connection specifications are in groups of four where each group defines a specific connection configuration. The terms of a connection group is defined as follows: 1st - The resource ID as defined by ctFDDIResourceID. 2nd - A specific instance of the physical resource. This will be a value between 1 and ctFDDIResourceNumbInstance for the particular resource ID in the first term. If a resource ID has more than one specific resource instance, but the whole resource can be connected, then this term will have the value '0' to signify all instances of the resource. 3rd - The connection ID for this specific physical resource. This value is the same as ctFDDINMConnectionID, and through the ctFDDINonMuxConnectionTable maps to a specific instance of SMT and MAC. For example if the value of this object is '1.1.2.2.1.1', then it states that resource 1, instance 1 is connected to connection ID 2 and resource 2, instance 1 is connected to connection ID 1 and is inserted into its FDDI ring. If a valid configuration is no connections then this object will have a value of '0.0.0'
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.3DisplayStringread-onlymandatory
ctFDDINMConfigDesc
OBJECT-TYPE
This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDINMConfig object.
1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.4DisplayStringread-onlymandatory
ctFDDINonMuxCapEnableTable
OBJECT-TYPE
This table describes the currently enabled configuration for each module.
1.3.6.1.4.1.52.4.1.2.5.1.2.2not-accessiblemandatory
ctFDDINonMuxCapEnableEntry
OBJECT-TYPE
Describes a specific configuration enable entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1not-accessiblemandatory
ctFDDINMEnableSlot
OBJECT-TYPE
A specific slot for which this configuration enable pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.1INTEGERread-onlymandatory
ctFDDINMCapEnable
OBJECT-TYPE
A specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object. This object, when read, will return the value of ctFDDINMConfigID for the presently enabled configuration.
1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2INTEGERread-writemandatory
ctFDDINonMuxConnectionTable
OBJECT-TYPE
This table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC instance in the 1512 FDDI MIB.
1.3.6.1.4.1.52.4.1.2.5.1.2.3not-accessiblemandatory
ctFDDINonMuxConnectionEntry
OBJECT-TYPE
Defines a specific configuration connection entry.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1not-accessiblemandatory
ctFDDINMConnectionSlot
OBJECT-TYPE
A specific slot for which this connection entry is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.1INTEGERread-onlymandatory
ctFDDINMConnectionID
OBJECT-TYPE
Describes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCapEnable.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.2INTEGERread-onlymandatory
ctFDDINMSMT
OBJECT-TYPE
A specific instance of SMT for which this entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.3INTEGERread-onlymandatory
ctFDDINMMAC
OBJECT-TYPE
A specific MAC that this connection entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.4INTEGERread-onlymandatory
ctFDDINMBytes
OBJECT-TYPE
The bandwidth utilization in bytes per second.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.5INTEGERread-onlymandatory
ctFDDINMFrames
OBJECT-TYPE
The bandwidth utilization in frames per second.
1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.6INTEGERread-onlymandatory
ctFDDINonMuxInterfaceTable
OBJECT-TYPE
This table describs the number of interfaces defined by each non multiplexing FDDI FNB module.
1.3.6.1.4.1.52.4.1.2.5.1.2.4not-accessiblemandatory
ctFDDINonMuxInterfaceEntry
OBJECT-TYPE
A specfic non multiplexing module interface definition.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1not-accessiblemandatory
ctFDDINMInterSlot
OBJECT-TYPE
A specific slot for which this inteface entry is defined.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.1INTEGERread-onlymandatory
ctFDDINMNumbInterfaces
OBJECT-TYPE
The number of interfaces defined on this particular module.
1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.2INTEGERread-onlymandatory
ctFDDIMux
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.5.1.3
ctFDDIMuxCapTable
OBJECT-TYPE
This table describes all possible configuration/capabilities defined for a FDDI multiplexing module.
1.3.6.1.4.1.52.4.1.2.5.1.3.1not-accessiblemandatory
ctFDDIMuxCapEntry
OBJECT-TYPE
Describes a specfic FDDI multiplexor capability/configuration entry.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1not-accessiblemandatory
ctFDDIMuxSlot
OBJECT-TYPE
Defines the slot within the chassis for which this multiplexed capability/configuration entry pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.1INTEGER (1..256)read-onlymandatory
ctFDDIMuxConfigID
OBJECT-TYPE
The instance of a particular configuration.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.2INTEGERread-onlymandatory
ctFDDIMuxConfig
OBJECT-TYPE
This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string, using a specified format for interpretation. The specific connections are in groups of four where each group defines a specific connection configuration. The terms of the connection group are defined as follows: 1st - Resource ID. The value is the same as ctFDDIResourceID for a specific resource entry. 2nd - Instance of the resource. This has a value in the range of 1 to ctFDDIResourceNumbInstance. 3rd - Path of the resource as input to the multiplexor. Paths are specified as 1 for the primary ring and 2 for the secondary. 4th - This is the multiplexor output channel that this resource comes out of the multiplexor. This value is the same as a value of ctFDDIMuxOutID. 5th - Ring Connectivity. This sub-identifier describes if the given mux-in resource (sub-identifiers 1-3) is inserted into the backplane FNB ring. Valid values are 0 for no 1 for yes. So for example a value of 1.1.1.1.0.2.2.2.2.1 is resource 1, instance 1 (primary) is on mux-out 1 and it's not inserted; resource 2, instance 2 (secondary) is on mux-out 2 and is inserted into the backplane. If a valid configuration is no connections then this object will have a value of '0.0.0.0.0'
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.3DisplayStringread-onlymandatory
ctFDDIMuxConfigDesc
OBJECT-TYPE
This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDIMuxConfig object.
1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.4DisplayStringread-onlymandatory
ctFDDIMuxCapEnableTable
OBJECT-TYPE
This table describes the currently enabled configuration for each module.
1.3.6.1.4.1.52.4.1.2.5.1.3.2not-accessiblemandatory
ctFDDIMuxCapEnableEntry
OBJECT-TYPE
Describes a specific configuration enable entry.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1not-accessiblemandatory
ctFDDIMuxEnableSlot
OBJECT-TYPE
A specific slot for which this configuration enable pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.1INTEGER (1..256)read-onlymandatory
ctFDDIMuxCapEnable
OBJECT-TYPE
A specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request of the value of this object will return the value of ctFDDIMuxConfigID for the presently enabled configuration.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.2INTEGERread-writemandatory
ctFDDIMuxMasterPortAssignmentChange
OBJECT-TYPE
Depicts the number of changes to the master port to multiplexor output mapping.
1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.3Counterread-onlymandatory
ctFDDIMuxOutTable
OBJECT-TYPE
Describes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI MIB.
1.3.6.1.4.1.52.4.1.2.5.1.3.3not-accessiblemandatory
ctFDDIMuxOutEntry
OBJECT-TYPE
Describes a particular multiplexor output.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1not-accessiblemandatory
ctFDDIMuxOutSlot
OBJECT-TYPE
The given slot for which this multiplexor output information pertains.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.1INTEGER (1..255)read-onlymandatory
ctFDDIMuxOutID
OBJECT-TYPE
The specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.2INTEGERread-onlymandatory
ctFDDIMuxOutMACIndex
OBJECT-TYPE
The MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has the value of 0, the given mux-out does not have a MAC.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.3INTEGER (1..65535)read-onlymandatory
ctFDDIMuxOutSMTIndex
OBJECT-TYPE
Identifies the instance of SMT as defined within the FDDI MIB.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.4INTEGER (1..65535)read-onlymandatory
ctFDDIMuxBytes
OBJECT-TYPE
The bandwidth utilization in bytes per second.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.5INTEGERread-onlymandatory
ctFDDIMuxFrames
OBJECT-TYPE
The bandwidth utilization in frames per second.
1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.6INTEGERread-onlymandatory
ctFDDIMuxMasterPortTable
OBJECT-TYPE
A list of entries that define master ports as they are defined for the given multiplexed FDDI connection.
1.3.6.1.4.1.52.4.1.2.5.1.3.4not-accessiblemandatory
ctFDDIMuxMasterPortEntry
OBJECT-TYPE
A specific FDDI-FNB multiplexed master port definition.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1not-accessiblemandatory
ctFDDIMuxMasterPortSlotID
OBJECT-TYPE
A specific instance of a slot as defined by chSlotID.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.1INTEGER (1..255)read-onlymandatory
ctFDDIMuxMasterPortID
OBJECT-TYPE
A unique identifier for this specific master port.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.2INTEGER (1..65535)read-onlymandatory
ctFDDIMuxMasterPortAssignment
OBJECT-TYPE
Provides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.3INTEGERread-writemandatory
ctFDDIMuxMasterPortIndex
OBJECT-TYPE
Defines a specific port within the FDDI MIBs fddimibPORTTable.
1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.4INTEGER (1..65535)read-onlymandatory
ctFDDISerialConfig
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.1.2.5.1.4
ctFDDINumbModules
OBJECT-TYPE
Describes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found within the ctFDDISerialConfigTable.
1.3.6.1.4.1.52.4.1.2.5.1.4.1INTEGER (0..14)read-onlymandatory
ctFDDISerialConfigTable
OBJECT-TYPE
This table describes the adminstrative control over each of the FNB serial control modules.
1.3.6.1.4.1.52.4.1.2.5.1.4.2not-accessiblemandatory
ctFDDISerialConfigEntry
OBJECT-TYPE
Describes the controls over a single FNB serial control entry.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1not-accessiblemandatory
ctFDDISerialSlotID
OBJECT-TYPE
Defines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.1INTEGERread-onlymandatory
ctFDDISerialAdminStatus
OBJECT-TYPE
Describes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and bypass FNB-2. insertFNB2(2) - The serial contolled module should be inserted into FNB-2 and bypass FNB-1. insertFNB1FNB2(3) - Insert the serial controlled module on both FNBs. bypass(4) - Bypass the connection to both FNBs. hwControlFNB1(5) - Use hardware settings for FNB-1. hwControlFNB2(6) - Use hardware settings for FNB-2. hwControl(7) - Use the hardware settings for both FNBs.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.2INTEGER {insertFNB1(1), insertFNB2(2), insertFNB1FNB2(3), bypass(4), hwControlFNB1(5), hwControlFNB2(6), hwControl(7)}read-writemandatory
ctFDDISerialOperStatus
OBJECT-TYPE
Describes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from FNB-2. insertFNB2(2) - The serial controlled module is bypassed from FNB-1 and inserted into FNB-2. insertFNB1FNB2(3) - The serial controlled module is inserted into both FNB-1 and FNB-2. bypass(4) - The serial controlled module is bypassed from both FNB-1 and FNB-2.
1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.3INTEGER {insertFNB1(1), insertFNB2(2), insertFNB1FNB2(3), bypass(4)}read-onlymandatory
ctFDDIModuleFPIMTable
OBJECT-TYPE
This table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs.
1.3.6.1.4.1.52.4.1.2.5.1.4.3not-accessiblemandatory
ctFDDIModuleFPIMEntry
OBJECT-TYPE
Describes a single FDDI FPIM on a module.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1not-accessiblemandatory
ctFddiFPIMSlotID
OBJECT-TYPE
Defines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.1INTEGERread-onlymandatory
ctFddiFPIM
OBJECT-TYPE
Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of ports from the top to the bottom, then the numbering will start from the left side and proceed top-to-bottom in each column.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2INTEGERread-onlymandatory
ctFddiFPIMStatus
OBJECT-TYPE
Describes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of notSupported(3) means that link status is not supported by this port and is unknown.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.4INTEGER {link(1), noLink(2), notSupported(3)}read-onlymandatory
ctFddiFPIMType
OBJECT-TYPE
Describes the type of FPIM as found in ctron-oids.
1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.5OBJECT IDENTIFIERread-onlymandatory