MIBs Depot

CTRON-COMMON-MIB

Registered at
1.3.6.1.4.1.52.1.6.1.2
1.3.6.1.4.1.52.1.6.1.3
1.3.6.1.4.1.52.1.6.1.4
1.3.6.1.4.1.52.1.6.2.3
1.3.6.1.4.1.52.1.6.2.6
1.3.6.1.4.1.52.1.6.2.7
1.3.6.1.4.1.52.1.6.2.8
1.3.6.1.4.1.52.1.6.2.9
1.3.6.1.4.1.52.1.6.2.10
1.3.6.1.4.1.52.1.6.3.1
Namespace
enterasys
Source file
CTRON-COMMON-MIB
Digest
sha256:b07a85df4e7ebc0ba9ddebedf73e55a86d65383acbc433d012f17741eafe017c

Imports

FromSymbols
IRM-OIDScommonRev1, dl, subSysDevice, subSysMMAC, ups
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTRON-COMMON-MIB
CTRON-OIDS
IRM-OIDS
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
deviceType
OBJECT-TYPE
The type of management board.
1.3.6.1.4.1.52.1.1.1.1INTEGER {other(1), iRM2(176), iRBM(177), iRM3(178), tRMBM-R(179), tRMBM-S(180), emm-E(185), tRMM(187), trmMim(190), mrxi24(65569), mrxi22(65570), mrxi34(65571), mrxi38(65572)}read-onlymandatory
deviceName
OBJECT-TYPE
A textual description on the entity managed by the resident agent. It is mandatory that this only con- tain printable ASCII characters.
1.3.6.1.4.1.52.1.1.1.2DisplayStringread-writemandatory
deviceIPAddress
OBJECT-TYPE
The Network address, in this case the IP address, of the device. This object is required for use by the Local Management Interface.
1.3.6.1.4.1.52.1.1.1.3IpAddressread-writemandatory
deviceTime
OBJECT-TYPE
The current time of day, in 24 hour format, as measured by the device. The representation shall use the standard HHMMSS format.
1.3.6.1.4.1.52.1.1.1.4DisplayString (SIZE(8))read-writemandatory
deviceDate
OBJECT-TYPE
The current date, as measured by the device. The representation shall use the standard MMDDYYYY format.
1.3.6.1.4.1.52.1.1.1.5DisplayString (SIZE(8))read-writemandatory
fnb2
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.2
fnbTR
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.2.1
fnbTRTable
OBJECT-TYPE
A list of entries that provide connection status of Token Ring subsystems, for the FNB.
1.3.6.1.4.1.52.1.6.1.2.1.1not-accessiblemandatory
fnbTREntry
OBJECT-TYPE
An entry in the fnbTRTable containing objects that provide FNB connection status for a Token Ring sub- system.
1.3.6.1.4.1.52.1.6.1.2.1.1.1not-accessiblemandatory
fnbTRIndex
OBJECT-TYPE
An unique value for each Token Ring subsystem. Its value ranges between 1 and chassisSlots. The value for each interface must remain constant, at least, from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.4.1.52.1.6.1.2.1.1.1.1INTEGERread-onlymandatory
fnbConnectLeft
OBJECT-TYPE
The Connected Left board (board n + 1) has the following states: Detached == 1 (Management (only management) detached, read/write). Attached == 2 (Management/AutoMode attached, read/write). Faulted == 3 (Management/AutoMode tried to attach but failed READ ONLY).
1.3.6.1.4.1.52.1.6.1.2.1.1.1.2INTEGER {detached(1), attached(2), faulted(3)}read-writemandatory
fnbConnectRight
OBJECT-TYPE
The Connected Right board (board n - 1) has the following states: Detached == 1 (Management (only management) detached, read/write). Attached == 2 (Management/AutoMode attached, read/write ). Faulted == 3 (Management/AutoMode tried to attach but failed, READ ONLY).
1.3.6.1.4.1.52.1.6.1.2.1.1.1.3INTEGER {detached(1), attached(2), faulted(3)}read-writemandatory
fnbBypass
OBJECT-TYPE
Denotes the bypass status of the current Token Ring board. Bypassed means the board is NOT attached to the FNB.
1.3.6.1.4.1.52.1.6.1.2.1.1.1.4INTEGER {off(1), on(2)}read-writemandatory
fnbRPBypass
OBJECT-TYPE
Denotes the Ring Port bypass status of the current Token Ring board. If this capability is not available on this board, the value 'other' is returned when read, and BADSETINFO when written.
1.3.6.1.4.1.52.1.6.1.2.1.1.1.5INTEGER {other(1), disabled(2), enabled(3)}read-writemandatory
fnbCSMACD
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.2.2
fnbCSMACDTable
OBJECT-TYPE
A list of entries that provide connection status of CSMA/CD subsystems, for the FNB.
1.3.6.1.4.1.52.1.6.1.2.2.1not-accessiblemandatory
fnbCSMACDEntry
OBJECT-TYPE
An entry in the fnbCSMACDTable containing objects that provide FNB connection status for a CSMA/CD subsystem.
1.3.6.1.4.1.52.1.6.1.2.2.1.1not-accessiblemandatory
fnbCSMACDIndex
OBJECT-TYPE
An unique value for each CSMACD subsystem. Its value ranges between 1 and chassisSlots. The value for each interface must remain constant, at least, from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.4.1.52.1.6.1.2.2.1.1.1INTEGERread-writemandatory
fnbConnect
OBJECT-TYPE
Denotes the connection status of the CSMA/CD board to the inter-RIC bus.
1.3.6.1.4.1.52.1.6.1.2.2.1.1.2INTEGER {connectB(1), connectC(2), disconnect(3), connectA(4), subnetB(5), subnetC(6), multiChannel(7), frontPanel(8)}read-writemandatory
fnbPortChanges
OBJECT-TYPE
Denotes the number of times any port on the given MIM has changed it's connection to the inter-RIC bus.
1.3.6.1.4.1.52.1.6.1.2.2.1.1.3Counterread-onlymandatory
fnbPortConnect
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.2.3
fnbPortConnectTable
OBJECT-TYPE
This table is used to control port association on ethernet devices. Only those boards that support port switching will be listed in this table.
1.3.6.1.4.1.52.1.6.1.2.3.1not-accessiblemandatory
fnbPortConnectEntry
OBJECT-TYPE
Describes a specific port connection entry.
1.3.6.1.4.1.52.1.6.1.2.3.1.1not-accessiblemandatory
fnbPortConnectBoardIndex
OBJECT-TYPE
An instance of a board for which this port assignment relationship exists.
1.3.6.1.4.1.52.1.6.1.2.3.1.1.1INTEGERread-onlymandatory
fnbPortConnectPortIndex
OBJECT-TYPE
An instance of a port for which this assignment relationship exists.
1.3.6.1.4.1.52.1.6.1.2.3.1.1.2INTEGERread-onlymandatory
fnbPortConnectPortAssignment
OBJECT-TYPE
The specific channel that the port is assigned.
1.3.6.1.4.1.52.1.6.1.2.3.1.1.3INTEGER {connectA(1), connectB(2), connectC(3)}read-writemandatory
fnbPortConnectCompID
OBJECT-TYPE
This is the component ID as defined in the chassis MIB that this port is associated with. These components will be repeater components.
1.3.6.1.4.1.52.1.6.1.2.3.1.1.4INTEGERread-onlymandatory
fnbPortConnectionChanges
OBJECT-TYPE
Maintains the number of times any port within the mangement domain of this MIM changes it's port assignment.
1.3.6.1.4.1.52.1.6.1.2.3.2Counterread-onlymandatory
chassis
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.3
chassisHWRev
OBJECT-TYPE
Define the hardware revision of the device or sys- tem chassis.
1.3.6.1.4.1.52.1.6.1.3.1INTEGERread-onlymandatory
chassisType
OBJECT-TYPE
Denotes the type of chassis.
1.3.6.1.4.1.52.1.6.1.3.2INTEGER {other(1), mMAC8FNB(2), mMAC5FNB(3), mMAC3FNB(4), mINIMMAC(5), mRXI(6), m3FNB(7), m5FNB(8), m8FNB(9), nonFNB(10), mMAC3FNBS(11), mMAC5FNBS(12), mMAC8FNBS(13), m8FNBS(14)}read-onlymandatory
chassisSlots
OBJECT-TYPE
Denotes the number of available chassis slots.
1.3.6.1.4.1.52.1.6.1.3.3INTEGERread-onlymandatory
chassisFNB
OBJECT-TYPE
Denotes the presence or absence of the FNB.
1.3.6.1.4.1.52.1.6.1.3.4INTEGER {absent(1), present(2)}read-onlymandatory
chassisAlarmEna
OBJECT-TYPE
Allow an audible alarm to be either enabled or dis- abled.
1.3.6.1.4.1.52.1.6.1.3.5INTEGER {disable(1), enable(2)}read-writemandatory
chassisAlarmState
OBJECT-TYPE
Denotes the current condition of the power supply fault detection circuit. Setting a value of chassisNoFaultCondition(1) disables the current chassis alarm condition, and stops the current audible alarm from sounding. Setting a value of chassisFaultCondition(2) is not allowed. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition.
1.3.6.1.4.1.52.1.6.1.3.6INTEGER {chassisNoFaultCondition(1), chassisFaultCondition(2)}read-writemandatory
environment
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.1.4
powerTable
OBJECT-TYPE
A list of power supply entries.
1.3.6.1.4.1.52.1.6.1.4.1not-accessiblemandatory
powerEntry
OBJECT-TYPE
An entry in the powerTable providing objects for a power supply.
1.3.6.1.4.1.52.1.6.1.4.1.1not-accessiblemandatory
powerSupplyNum
OBJECT-TYPE
Denotes the power supply that may have failed.
1.3.6.1.4.1.52.1.6.1.4.1.1.1INTEGERread-onlymandatory
powerSupplyState
OBJECT-TYPE
Denotes the power supply's state.
1.3.6.1.4.1.52.1.6.1.4.1.1.2INTEGER {infoNotAvailable(1), notInstalled(2), installedAndOperating(3), installedAndNotOperating(4)}read-onlymandatory
powerSupplyId
OBJECT-TYPE
Identifies the type of power supply. For example, this could be used to identify power supplies which support additional remote management capabilities.
1.3.6.1.4.1.52.1.6.1.4.1.1.3OBJECT IDENTIFIERread-onlymandatory
powerSupplyRedun
OBJECT-TYPE
Identifies whether power redundancy is available within the chassis. Devices that do not support power supply redundancy, will return infoNotAvailable.
1.3.6.1.4.1.52.1.6.1.4.1.1.4INTEGER {redundancyAvail(1), redundancyNotAvail(2), infoNotAvailable(3)}read-onlymandatory
powerSupplyRemoteDisable
OBJECT-TYPE
Provides Enable/Disable control of the power supply. For devices that do not support this capability, a set attempt will return BADVALUE, and a read will always return infoNotAvailable.
1.3.6.1.4.1.52.1.6.1.4.1.1.5INTEGER {enable(1), disable(2), infoNotAvailable(3)}read-writemandatory
nB55
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.3
nB55HWAddress
OBJECT-TYPE
The device's MAC address.
1.3.6.1.4.1.52.1.6.2.3.1PhysAddressread-onlymandatory
nB55HWRev
OBJECT-TYPE
Denotes the revision of the nB55 board. A value of one denotes Revision 1, a value of two denotes Revi- sion 2, and so on.
1.3.6.1.4.1.52.1.6.2.3.2INTEGERread-onlymandatory
nB55FWRev
OBJECT-TYPE
Denotes the revision of firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.2.3.3OCTET STRING (SIZE(2))read-onlymandatory
mRXI
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.6
mRXIHWAddress
OBJECT-TYPE
The device's MAC address.
1.3.6.1.4.1.52.1.6.2.6.1PhysAddressread-onlymandatory
mRXIHWRev
OBJECT-TYPE
Denotes the revision of the mRXI board. A value of one denotes Revision 1, a value of two denotes Revi- sion 2, and so on.
1.3.6.1.4.1.52.1.6.2.6.2INTEGERread-onlymandatory
mRXIFWRev
OBJECT-TYPE
Denotes the revision of firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.2.6.3OCTET STRING (SIZE(2))read-onlymandatory
iRM3
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.7
iRM3HWAddress
OBJECT-TYPE
The device's MAC address.
1.3.6.1.4.1.52.1.6.2.7.1PhysAddressread-onlymandatory
iRM3HWRev
OBJECT-TYPE
Denotes the revision of the IRM3 board. A value of one denotes Revision 1, a value of two denotes Revi- sion 2, and so on.
1.3.6.1.4.1.52.1.6.2.7.2INTEGERread-onlymandatory
iRM3FWRev
OBJECT-TYPE
Denotes the revision of firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.2.7.3OCTET STRING (SIZE(2))read-onlymandatory
iRM3PortAssoc
OBJECT-TYPE
Controls how front panel ports are associated with the Irm3.
1.3.6.1.4.1.52.1.6.2.7.4INTEGER {aoffFrp(5), arpFoff(6)}read-writemandatory
iRM3BPSupport
OBJECT-TYPE
Denotes whether or not Backplane Protocol Support is present in the current version of the IRM3.
1.3.6.1.4.1.52.1.6.2.7.5INTEGER {notSupported(1), supported(2)}read-onlymandatory
tRMM
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.8
tRMMHWAddress
OBJECT-TYPE
The device's MAC address.
1.3.6.1.4.1.52.1.6.2.8.1PhysAddressread-onlymandatory
tRMMHWRev
OBJECT-TYPE
Denotes the revision of the tRMM board. A value of one denotes Revision 1, a value of two denotes Revi- sion 2, and so on.
1.3.6.1.4.1.52.1.6.2.8.2INTEGERread-onlymandatory
tRMMFWRev
OBJECT-TYPE
Denotes the revision of firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.2.8.3OCTET STRING (SIZE(2))read-onlymandatory
eMME
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.9
eMMEHWAddress
OBJECT-TYPE
The device's MAC address.
1.3.6.1.4.1.52.1.6.2.9.1PhysAddressread-onlymandatory
eMMEHWRev
OBJECT-TYPE
Denotes the revision of the eMME board. A value of one denotes Revision 1, a value of two denotes Revi- sion 2, and so on.
1.3.6.1.4.1.52.1.6.2.9.2INTEGERread-onlymandatory
eMMEFWRev
OBJECT-TYPE
Denotes the revision of firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.2.9.3OCTET STRING (SIZE(1..10))read-onlymandatory
eMMEBoardMap
OBJECT-TYPE
Denotes a bit encoded representation of the slots that contain MIM boards. If a bit is a one then the board is present.
1.3.6.1.4.1.52.1.6.2.9.4INTEGERread-onlymandatory
fPRedundancy
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.10
fPRedund
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.2.10.1
fPRedundReset
OBJECT-TYPE
If this object is set to Reset it will cause a reset of the front panel redundancy. Setting this object to NoReset will do nothing. This object will always be read as NoReset.
1.3.6.1.4.1.52.1.6.2.10.1.1INTEGER {noReset(1), reset(2)}read-writemandatory
fPRedundPollInterval
OBJECT-TYPE
Get/Set the number of seconds between polls for front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.1.2INTEGERread-writemandatory
fPRedundRetrys
OBJECT-TYPE
Get/Set the the number of unanswered polls allowed for the front panel redundancy before it switches ports.
1.3.6.1.4.1.52.1.6.2.10.1.3INTEGERread-writemandatory
fPRedundNumAddr
OBJECT-TYPE
Get the number of IP Addresses associated with front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.1.4INTEGERread-onlymandatory
fPRedundAddAddr
OBJECT-TYPE
Add an IP Address to the polling list for the front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.1.5IpAddressread-writemandatory
fPRedundDelAddr
OBJECT-TYPE
Delete an IP Address from the polling list for the front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.1.6IpAddressread-writemandatory
fPRedundActivePort
OBJECT-TYPE
Get/Set the front panel port you want to be active when front panel redundancy is enabled.
1.3.6.1.4.1.52.1.6.2.10.1.7INTEGERread-writemandatory
fPRedundEnable
OBJECT-TYPE
If this object is set to enable, the front panel redundancy will be activated. If this object is set to disable, the front panel redundancy will be deactivated. When read, this object will returns the state of the object based on the last request made.
1.3.6.1.4.1.52.1.6.2.10.1.8INTEGER {disable(1), enable(2)}read-writemandatory
fPRedundAddrTable
OBJECT-TYPE
A list of entries that provide IP address information for front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.2not-accessiblemandatory
fPRedundAddrEntry
OBJECT-TYPE
An entry in the fPRedundAddrTable providing objects for front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.2.1not-accessiblemandatory
fPRedundAddrId
OBJECT-TYPE
A unique value identifying an element in a sequence of member IP Addresses which belong to the front panel redundancy. This value goes from 1 to the maximum number of IP Addresses which may be included in front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.2.1.1INTEGERread-onlymandatory
fPRedundAddrIPAddr
OBJECT-TYPE
Returns an IP Address associated with the front panel redundancy.
1.3.6.1.4.1.52.1.6.2.10.2.1.2IpAddressread-onlymandatory
upsVersion
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.3.1
upsRevision
OBJECT-IDENTITY
1.3.6.1.4.1.52.1.6.3.1.1
upsID
OBJECT-TYPE
Denotes a type code which refers to the manufactur- ers and model of the UPS.
1.3.6.1.4.1.52.1.6.3.1.1.1INTEGER {other(1), aPCModel370(257), aPCModel400(258), aPCModel600(259), aPCModel900(260), aPCModel1250(261), aPCModel2000(262)}read-writemandatory
upsUpTime
OBJECT-TYPE
Denotes the operating time, in hours, since the UPS was last powered on.
1.3.6.1.4.1.52.1.6.3.1.1.2INTEGERread-onlymandatory
upsDisable
OBJECT-TYPE
Allows the UPS to be disabled. A set turns of the UPS for those systems, so equipped. A get/get-next always returns 0.
1.3.6.1.4.1.52.1.6.3.1.1.3INTEGERread-writedeprecated
upsDisconnect
OBJECT-TYPE
Allows the UPS backup power system to conserve its battery. Setting the object to a value of 1 turns off the power system. A get/get-next always retuns a 0.
1.3.6.1.4.1.52.1.6.3.1.1.4INTEGERread-writemandatory
upsTest
OBJECT-TYPE
Denotes the status performed on the UPS. A write unitOK(1) intiates the test. A read indicates status of test.
1.3.6.1.4.1.52.1.6.3.1.1.5INTEGER {unitOK(1), unitFailed(2), badBattery(3), noRecentTest(4), underTest(5)}read-writemandatory
upsBatteryCapacity
OBJECT-TYPE
Denotes the percentage of battery capacity left, 100% being a fully-charged battery.
1.3.6.1.4.1.52.1.6.3.1.1.6INTEGERread-onlymandatory
upsACLineVoltsIn
OBJECT-TYPE
Denotes the input AC utility line voltage.
1.3.6.1.4.1.52.1.6.3.1.1.7INTEGERread-onlymandatory
upsBatteryVoltsOut
OBJECT-TYPE
Denotes the battery voltage.
1.3.6.1.4.1.52.1.6.3.1.1.8INTEGERread-onlymandatory
dlForceOnBoot
OBJECT-TYPE
When set to a 1, the system will request a download, during the next system restart. If no server is found and the current image in flash memory is valid, the system will boot using the flash-resident image.
1.3.6.1.4.1.52.1.6.4.1INTEGERread-writemandatory
dlCommitRAMToFlash
OBJECT-TYPE
When written with a 1, the boot software will erase flash memory, compress the downloaded code, and save the compressed image into flash memory. Upon com- pletion of this operation, the flash memory driver resets this object to 0, indicating completion of the programming operation.
1.3.6.1.4.1.52.1.6.4.2INTEGERread-writemandatory
dlInitiateColdBoot
OBJECT-TYPE
When written with a 1, the boot software intiates a system reboot. All MIB variables used to control the exact nature of the download should be set, prior to activating a system reset. A read always returns a 0.
1.3.6.1.4.1.52.1.6.4.3INTEGERread-writemandatory
dlTFTPRequestHost
OBJECT-TYPE
The IP address of the server to be used, when firmware is to be loaded across the network.
1.3.6.1.4.1.52.1.6.4.4IpAddressread-writemandatory
dlTFTPRequest
OBJECT-TYPE
The filename requested of the server, when firmware is to be loaded across the network.
1.3.6.1.4.1.52.1.6.4.5DisplayStringread-writemandatory
dlLastImageFilename
OBJECT-TYPE
Filename of the last image to be successfully loaded into memory.
1.3.6.1.4.1.52.1.6.4.6DisplayStringread-onlymandatory
dlLastServerIPAddress
OBJECT-TYPE
The IP address of the server used to load the present image in flash memory.
1.3.6.1.4.1.52.1.6.4.7IpAddressread-onlymandatory
dlFlashSize
OBJECT-TYPE
Denotes the size, in bytes, of flash memory con- tained on this module.
1.3.6.1.4.1.52.1.6.4.8INTEGERread-onlymandatory
dlFlashCount
OBJECT-TYPE
Denotes the number of times that flash memory has been reprogrammed. This value is initialzed to 1, when the module is initially powered up.
1.3.6.1.4.1.52.1.6.4.9INTEGERread-onlymandatory
dlFirmwareBase
OBJECT-TYPE
Denotes the starting address of the firmware in RAM.
1.3.6.1.4.1.52.1.6.4.10INTEGERread-onlymandatory
dlFirmwareTop
OBJECT-TYPE
Denotes the ending address of firmware in RAM.
1.3.6.1.4.1.52.1.6.4.11INTEGERread-onlymandatory
dlFirmwareStart
OBJECT-TYPE
Denotes the start address of the firmware, in RAM, as established by the boot process.
1.3.6.1.4.1.52.1.6.4.12INTEGERread-onlymandatory
dlBootRev
OBJECT-TYPE
Denotes the revision of boot firmware in the module. The first octets provides the version, and the second provides the revision.
1.3.6.1.4.1.52.1.6.4.13OCTET STRING (SIZE(0..10))read-onlymandatory
dlForceBootp
OBJECT-TYPE
When set, this variable forces the client to send a BOOTP request packet when rebooting. The client will make several attempts before timing out if a server does not respond. This variable stays set. When set to a 1 it should always be read as a one. When set to zero it should always be read as zero.
1.3.6.1.4.1.52.1.6.4.14INTEGERread-writemandatory
dlServerName
OBJECT-TYPE
This OID is reserved for future use of the Bootp server name. This field can be used when a client wants to get boot information from a particular bootp server.
1.3.6.1.4.1.52.1.6.4.15OCTET STRINGread-writemandatory
dlOnLineDownLoad
OBJECT-TYPE
During normal operation this object has the value of 1. By setting this object to a value of forceDownLoad(2) an online download will be performed. By setting this object to a value of forceDownLoadReset(3) an online down load will be performed and a reset will be forced upon successful completion of the download.
1.3.6.1.4.1.52.1.6.4.16INTEGER {normalOperation(1), forceDownLoad(2), forceDownLoadReset(3)}read-writemandatory
dlOperStatus
OBJECT-TYPE
This object reflects the status of the download code. A value of normalOperation(3) reflects either a down load was started but has finished normally and no reset was specified or no down load has been started. A value of downLoadActive only appears while a down load is in progress. A value of downLoadCompleteError reflects that a down load was started however an error was detected.
1.3.6.1.4.1.52.1.6.4.17INTEGER {other(1), unknown(2), normalOperation(3), downLoadActive(4), downLoadCompleteError(5)}read-onlymandatory
dlNetAddress
OBJECT-TYPE
IP Address of the server to be used when an image is to be downloaded using the Runtime TFTP Download.
1.3.6.1.4.1.52.1.6.4.18IpAddressread-writemandatory
dlFileName
OBJECT-TYPE
Filename requested of the server when an image is to be downloaded using the Runtime TFTP Download. This should be a complete path filename.
1.3.6.1.4.1.52.1.6.4.19OCTET STRING (SIZE(0..128))read-writemandatory
dlErrorString
OBJECT-TYPE
If the value of ctDLOperStatus is downloadCompleteError(5) then this object will provide a more complete description of the error. Otherwise this object will be the zero length string.
1.3.6.1.4.1.52.1.6.4.20DisplayStringread-onlymandatory
dlTftpServerGatewayIPAddress
OBJECT-TYPE
The IP address of the gateway/router which connects this SNMP agent to the TFTP server.