MIBs Depot

CTRON-CHASSIS-MIB

Registered at
1.3.6.1.4.1.52.4.3.1.1
1.3.6.1.4.1.52.4.3.1.2
1.3.6.1.4.1.52.4.3.1.3
Namespace
enterasys
Source file
CTRON-CHASSIS-MIB
Digest
sha256:a93b4602a1d1c14e289440a6509ba114b3561d559a8de601828a3349917e5020

Imports

FromSymbols
CTRON-MIB-NAMESctronChassis
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTRON-CHASSIS-MIB
CTRON-MIB-NAMES
CTRON-OIDS
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ctChas
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.3.1.1
ctChasFNB
OBJECT-TYPE
Denotes the presence or absence of the FNB.
1.3.6.1.4.1.52.4.3.1.1.1INTEGER {absent(1), present(2)}read-onlymandatory
ctChasAlarmEna
OBJECT-TYPE
Allow an audible alarm to be either enabled or dis- abled. Setting this object to disable(1) will prevent an audible alarm from being heard and will also stop the sound from a current audible alarm. Setting this object to enable(2) will allow an audible alarm to be heard and will also enable the sound from a current audible alarm, if it has previously been disabled. This object will read with the current setting.
1.3.6.1.4.1.52.4.3.1.1.2INTEGER {disable(1), enable(2), notSupported(3)}read-writemandatory
chassisAlarmState
OBJECT-TYPE
Denotes the current condition of the power supply fault detection circuit. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition.
1.3.6.1.4.1.52.4.3.1.1.3INTEGER {chassisNoFaultCondition(1), chassisFaultCondition(2), notSupported(3)}read-onlymandatory
ctEnviron
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.3.1.2
ctChasPowerTable
OBJECT-TYPE
A list of power supply entries.
1.3.6.1.4.1.52.4.3.1.2.1not-accessiblemandatory
ctChasPowerEntry
OBJECT-TYPE
An entry in the powerTable providing objects for a power supply.
1.3.6.1.4.1.52.4.3.1.2.1.1not-accessiblemandatory
ctChasPowerSupplyNum
OBJECT-TYPE
Denotes the power supply.
1.3.6.1.4.1.52.4.3.1.2.1.1.1INTEGERread-onlymandatory
ctChasPowerSupplyState
OBJECT-TYPE
Denotes the power supply's state.
1.3.6.1.4.1.52.4.3.1.2.1.1.2INTEGER {infoNotAvailable(1), notInstalled(2), installedAndOperating(3), installedAndNotOperating(4)}read-onlymandatory
ctChasPowerSupplyType
OBJECT-TYPE
Denotes the power supply type.
1.3.6.1.4.1.52.4.3.1.2.1.1.3INTEGER {ac-dc(1), dc-dc(2), notSupported(3), highOutput(4)}read-onlymandatory
ctChasPowerSupplyRedundancy
OBJECT-TYPE
Denotes whether or not the power supply is redundant.
1.3.6.1.4.1.52.4.3.1.2.1.1.4INTEGER {redundant(1), notRedundant(2), notSupported(3)}read-onlymandatory
ctFanModule
OBJECT-IDENTITY
1.3.6.1.4.1.52.4.3.1.3
ctChasFanModuleTable
OBJECT-TYPE
A list of fan module entries.
1.3.6.1.4.1.52.4.3.1.3.1not-accessiblemandatory
ctChasFanModuleEntry
OBJECT-TYPE
An entry in the fan module Table providing objects for a fan module.
1.3.6.1.4.1.52.4.3.1.3.1.1not-accessiblemandatory
ctChasFanModuleNum
OBJECT-TYPE
Denotes the Fan module that may have failed.
1.3.6.1.4.1.52.4.3.1.3.1.1.1INTEGERread-onlymandatory
ctChasFanModuleState
OBJECT-TYPE
Denotes the fan modules state.
1.3.6.1.4.1.52.4.3.1.3.1.1.2INTEGER {infoNotAvailable(1), notInstalled(2), installedAndOperating(3), installedAndNotOperating(4)}read-onlymandatory