CTRON-CHASSIS-MIB
- Registered at
- 1.3.6.1.4.1.52.4.3.1.11.3.6.1.4.1.52.4.3.1.21.3.6.1.4.1.52.4.3.1.3
- Namespace
- enterasys
- Source file
CTRON-CHASSIS-MIB- Digest
sha256:a93b4602a1d1c14e289440a6509ba114b3561d559a8de601828a3349917e5020
Imports
| From | Symbols |
|---|---|
| CTRON-MIB-NAMES | ctronChassis |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CTRON-CHASSIS-MIB CTRON-MIB-NAMES CTRON-OIDS SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ctChas OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.3.1.1 | |||
| ctChasFNB OBJECT-TYPE Denotes the presence or absence of the FNB. | 1.3.6.1.4.1.52.4.3.1.1.1 | INTEGER {absent(1), present(2)} | read-only | mandatory |
| ctChasAlarmEna OBJECT-TYPE Allow an audible alarm to be either enabled or dis- abled. Setting this object to disable(1) will prevent an audible alarm from being heard and will also stop the sound from a current audible alarm. Setting this object to enable(2) will allow an audible alarm to be heard and will also enable the sound from a current audible alarm, if it has previously been disabled. This object will read with the current setting. | 1.3.6.1.4.1.52.4.3.1.1.2 | INTEGER {disable(1), enable(2), notSupported(3)} | read-write | mandatory |
| chassisAlarmState OBJECT-TYPE Denotes the current condition of the power supply fault detection circuit. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition. | 1.3.6.1.4.1.52.4.3.1.1.3 | INTEGER {chassisNoFaultCondition(1), chassisFaultCondition(2), notSupported(3)} | read-only | mandatory |
| ctEnviron OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.3.1.2 | |||
| ctChasPowerTable OBJECT-TYPE A list of power supply entries. | 1.3.6.1.4.1.52.4.3.1.2.1 | not-accessible | mandatory | |
| ctChasPowerEntry OBJECT-TYPE An entry in the powerTable providing objects for a power supply. | 1.3.6.1.4.1.52.4.3.1.2.1.1 | not-accessible | mandatory | |
| ctChasPowerSupplyNum OBJECT-TYPE Denotes the power supply. | 1.3.6.1.4.1.52.4.3.1.2.1.1.1 | INTEGER | read-only | mandatory |
| ctChasPowerSupplyState OBJECT-TYPE Denotes the power supply's state. | 1.3.6.1.4.1.52.4.3.1.2.1.1.2 | INTEGER {infoNotAvailable(1), notInstalled(2), installedAndOperating(3), installedAndNotOperating(4)} | read-only | mandatory |
| ctChasPowerSupplyType OBJECT-TYPE Denotes the power supply type. | 1.3.6.1.4.1.52.4.3.1.2.1.1.3 | INTEGER {ac-dc(1), dc-dc(2), notSupported(3), highOutput(4)} | read-only | mandatory |
| ctChasPowerSupplyRedundancy OBJECT-TYPE Denotes whether or not the power supply is redundant. | 1.3.6.1.4.1.52.4.3.1.2.1.1.4 | INTEGER {redundant(1), notRedundant(2), notSupported(3)} | read-only | mandatory |
| ctFanModule OBJECT-IDENTITY | 1.3.6.1.4.1.52.4.3.1.3 | |||
| ctChasFanModuleTable OBJECT-TYPE A list of fan module entries. | 1.3.6.1.4.1.52.4.3.1.3.1 | not-accessible | mandatory | |
| ctChasFanModuleEntry OBJECT-TYPE An entry in the fan module Table providing objects for a fan module. | 1.3.6.1.4.1.52.4.3.1.3.1.1 | not-accessible | mandatory | |
| ctChasFanModuleNum OBJECT-TYPE Denotes the Fan module that may have failed. | 1.3.6.1.4.1.52.4.3.1.3.1.1.1 | INTEGER | read-only | mandatory |
| ctChasFanModuleState OBJECT-TYPE Denotes the fan modules state. | 1.3.6.1.4.1.52.4.3.1.3.1.1.2 | INTEGER {infoNotAvailable(1), notInstalled(2), installedAndOperating(3), installedAndNotOperating(4)} | read-only | mandatory |