MIBs Depot

CTMMIBCUSTOM

Namespace
ctm
Source file
CTMMIBCUSTOM
Digest
sha256:35b6e664a9acf0cd7819b7121f78b89147f5da4fcc20000f64cb92a082810a20

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CTMMIBCUSTOM
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
lastmilegear
OBJECT-IDENTITY
1.3.6.1.4.1.25868
mibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.25868.1
version
OBJECT-TYPE
Version of Web GUI - Version of Web GUI Interface currently running on CTM
1.3.6.1.4.1.25868.1.1OCTET STRINGread-onlymandatory
site
OBJECT-TYPE
Site Name - Site name as stored on CTM
1.3.6.1.4.1.25868.1.2OCTET STRINGread-onlymandatory
lastIP
OBJECT-TYPE
Last IP Address Login - Last IP address captured at Login Attempt
1.3.6.1.4.1.25868.1.3OCTET STRINGread-onlymandatory
lastTime
OBJECT-TYPE
Last Time Login - Last time of Login attempt
1.3.6.1.4.1.25868.1.4OCTET STRINGread-onlymandatory
nSats
OBJECT-TYPE
Number Satellites in View - Number of Satellites in view of GPS Receiver Antenna being used for timing calculations
1.3.6.1.4.1.25868.1.5INTEGERread-onlymandatory
pwrP
OBJECT-TYPE
Master Primary Power - Master ?1? = Power OK, ?0? = Power Off or Low
1.3.6.1.4.1.25868.1.6INTEGERread-onlymandatory
pwrS
OBJECT-TYPE
Master Secondary Power - Master ?1? = Power OK, ?0? = Power Off or Low
1.3.6.1.4.1.25868.1.7INTEGERread-onlymandatory
cbTrip
OBJECT-TYPE
Master Circuit Breaker Trip Bit Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
1.3.6.1.4.1.25868.1.8OCTET STRINGread-onlymandatory
tempC
OBJECT-TYPE
Master Temperature
1.3.6.1.4.1.25868.1.9INTEGERread-onlymandatory
voltsM1
OBJECT-TYPE
Master Primary Power In Voltage - In Tenths of a Volt
1.3.6.1.4.1.25868.1.10INTEGERread-onlymandatory
voltsM2
OBJECT-TYPE
Master Secondary Power In Voltage - In Tenths of a Volt
1.3.6.1.4.1.25868.1.11INTEGERread-onlymandatory
portOnM
OBJECT-TYPE
Master Ports ON Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
1.3.6.1.4.1.25868.1.12OCTET STRINGread-onlymandatory
portSyncM
OBJECT-TYPE
Master Ports Sync Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
1.3.6.1.4.1.25868.1.13OCTET STRINGread-onlymandatory
portPwrM1
OBJECT-TYPE
Master Power Port 1 - (in tenths of a Watt) delivered on Port 1
1.3.6.1.4.1.25868.1.14INTEGERread-onlymandatory
portPwrM2
OBJECT-TYPE
Master Power Port 2 - (in tenths of a Watt) delivered on Port 2
1.3.6.1.4.1.25868.1.15INTEGERread-onlymandatory
portPwrM3
OBJECT-TYPE
Master Power Port 3 - (in tenths of a Watt) delivered on Port 3
1.3.6.1.4.1.25868.1.16INTEGERread-onlymandatory
portPwrM4
OBJECT-TYPE
Master Power Port 4 - (in tenths of a Watt) delivered on Port 4
1.3.6.1.4.1.25868.1.17INTEGERread-onlymandatory
portPwrM5
OBJECT-TYPE
Master Power Port 5 - (in tenths of a Watt) delivered on Port 5
1.3.6.1.4.1.25868.1.18INTEGERread-onlymandatory
portPwrM6
OBJECT-TYPE
Master Power Port 6 - (in tenths of a Watt) delivered on Port 6
1.3.6.1.4.1.25868.1.19INTEGERread-onlymandatory
portPwrM7
OBJECT-TYPE
Master Power Port 7 - (in tenths of a Watt) delivered on Port 7
1.3.6.1.4.1.25868.1.20INTEGERread-onlymandatory
portPwrM8
OBJECT-TYPE
Master Power Port 8 - (in tenths of a Watt) delivered on Port 8
1.3.6.1.4.1.25868.1.21INTEGERread-onlymandatory
pwrSP
OBJECT-TYPE
Slave Primary Power - Master ?1? = Power OK, ?0? = Power Off or Low
1.3.6.1.4.1.25868.1.23INTEGERread-onlymandatory
pwrSS
OBJECT-TYPE
Slave Secondary Power - Master ?1? = Power OK, ?0? = Power Off or Low
1.3.6.1.4.1.25868.1.24INTEGERread-onlymandatory
voltsS1
OBJECT-TYPE
Slave Primary Power In Voltage - In Tenths of a Volt
1.3.6.1.4.1.25868.1.27INTEGERread-onlymandatory
voltsS2
OBJECT-TYPE
Slave Secondary Power In Voltage - In Tenths of a Volt
1.3.6.1.4.1.25868.1.28INTEGERread-onlymandatory
portOnS
OBJECT-TYPE
Slave Ports ON Enabled Status - Slave ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
1.3.6.1.4.1.25868.1.29OCTET STRINGread-onlymandatory
portSyncS
OBJECT-TYPE
Slave Ports Sync Enabled Status - Slave ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
1.3.6.1.4.1.25868.1.30OCTET STRINGread-onlymandatory
portPwrS1
OBJECT-TYPE
Slave Power Port 1 - (in tenths of a Watt) delivered on Port 1
1.3.6.1.4.1.25868.1.31INTEGERread-onlymandatory
portPwrS2
OBJECT-TYPE
Slave Power Port 2 - (in tenths of a Watt) delivered on Port 2
1.3.6.1.4.1.25868.1.32INTEGERread-onlymandatory
portPwrS3
OBJECT-TYPE
Slave Power Port 3 - (in tenths of a Watt) delivered on Port 3
1.3.6.1.4.1.25868.1.33INTEGERread-onlymandatory
portPwrS4
OBJECT-TYPE
Slave Power Port 4 - (in tenths of a Watt) delivered on Port 4
1.3.6.1.4.1.25868.1.34INTEGERread-onlymandatory
portPwrS5
OBJECT-TYPE
Slave Power Port 5 - (in tenths of a Watt) delivered on Port 5
1.3.6.1.4.1.25868.1.35INTEGERread-onlymandatory
portPwrS6
OBJECT-TYPE
Slave Power Port 6 - (in tenths of a Watt) delivered on Port 6
1.3.6.1.4.1.25868.1.36INTEGERread-onlymandatory
portPwrS7
OBJECT-TYPE
Slave Power Port 7 - (in tenths of a Watt) delivered on Port 7
1.3.6.1.4.1.25868.1.37INTEGERread-onlymandatory
portPwrS8
OBJECT-TYPE
Slave Power Port 8 - (in tenths of a Watt) delivered on Port 8
1.3.6.1.4.1.25868.1.38INTEGERread-onlymandatory
modeReqM
OBJECT-TYPE
Master CTM2 Port Type Setting - Master ?00?=Type A (Canopy) ?10?=Type B (OFDM), ?01? = Type C (POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE 24V mode, CTM2 C Only) listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
1.3.6.1.4.1.25868.1.39OCTET STRINGread-onlymandatory
trpCntGM1
OBJECT-TYPE
Master Auto Restart Count Port 1 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 1
1.3.6.1.4.1.25868.1.45INTEGERread-onlymandatory
trpCntGM2
OBJECT-TYPE
Master Auto Restart Count Port 2 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 2
1.3.6.1.4.1.25868.1.46INTEGERread-onlymandatory
trpCntGM3
OBJECT-TYPE
Master Auto Restart Count Port 3 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 3
1.3.6.1.4.1.25868.1.47INTEGERread-onlymandatory
trpCntGM4
OBJECT-TYPE
Master Auto Restart Count Port 4 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 4
1.3.6.1.4.1.25868.1.48INTEGERread-onlymandatory
trpCntGM5
OBJECT-TYPE
Master Auto Restart Count Port 5 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 5
1.3.6.1.4.1.25868.1.49INTEGERread-onlymandatory
trpCntGM6
OBJECT-TYPE
Master Auto Restart Count Port 6 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 6
1.3.6.1.4.1.25868.1.50INTEGERread-onlymandatory
trpCntGM7
OBJECT-TYPE
Master Auto Restart Count Port 7 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 7
1.3.6.1.4.1.25868.1.51INTEGERread-onlymandatory
trpCntGM8
OBJECT-TYPE
Master Auto Restart Count Port 8 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 8
1.3.6.1.4.1.25868.1.52INTEGERread-onlymandatory
trpCntBM1
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 1 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 1
1.3.6.1.4.1.25868.1.53INTEGERread-onlymandatory
trpCntBM2
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 2 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 2
1.3.6.1.4.1.25868.1.54INTEGERread-onlymandatory
trpCntBM3
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 3 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 3
1.3.6.1.4.1.25868.1.55INTEGERread-onlymandatory
trpCntBM4
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 4 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 4
1.3.6.1.4.1.25868.1.56INTEGERread-onlymandatory
trpCntBM5
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 5 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 5
1.3.6.1.4.1.25868.1.57INTEGERread-onlymandatory
trpCntBM6
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 6 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 6
1.3.6.1.4.1.25868.1.58INTEGERread-onlymandatory
trpCntBM7
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 7 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 7
1.3.6.1.4.1.25868.1.59INTEGERread-onlymandatory
trpCntBM8
OBJECT-TYPE
Master Ckt Breaker Auto Restart Fail Count Port 8 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 8
1.3.6.1.4.1.25868.1.60INTEGERread-onlymandatory

Notifications

NameOIDStatus
lostEthernetConnection
NOTIFICATION-TYPE
Lost Ethernet Connection
1.3.6.1.4.1.25868.1.0.0
masterPrimayPowerLost
NOTIFICATION-TYPE
Master Primary Power Lost
1.3.6.1.4.1.25868.1.0.1
masterSecondaryPowerLost
NOTIFICATION-TYPE
Master Secondary Power Lost
1.3.6.1.4.1.25868.1.0.2
gpsSignalLost
NOTIFICATION-TYPE
GPS Signal Lost
1.3.6.1.4.1.25868.1.0.3
masterTempatureError
NOTIFICATION-TYPE
Master Temperature Error
1.3.6.1.4.1.25868.1.0.4
masterCircuitBreakerTripCode
NOTIFICATION-TYPE
Master Circuit Breaker Trip Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
1.3.6.1.4.1.25868.1.0.5
loginFailedAttempt
NOTIFICATION-TYPE
Login Failed Attempt
1.3.6.1.4.1.25868.1.0.6
settingsChanged
NOTIFICATION-TYPE
CTM Settings Changed
1.3.6.1.4.1.25868.1.0.7
masterPrimaryPowerOK
NOTIFICATION-TYPE
Master Primary Power OK
1.3.6.1.4.1.25868.1.0.10
masterSecondaryPowerOK
NOTIFICATION-TYPE
Master Secondary Power OK
1.3.6.1.4.1.25868.1.0.20
gpsSignalOK
NOTIFICATION-TYPE
GPS Signal OK
1.3.6.1.4.1.25868.1.0.30
tempatureOK
NOTIFICATION-TYPE
Temperature OK
1.3.6.1.4.1.25868.1.0.40
circuitBreakersOK
NOTIFICATION-TYPE
Circuit Breakers OK
1.3.6.1.4.1.25868.1.0.50
masterAutoRestartCBCompletedOK
NOTIFICATION-TYPE
Master Auto Restart CB Completed OK
1.3.6.1.4.1.25868.1.0.52
loginOK
NOTIFICATION-TYPE
Login OK
1.3.6.1.4.1.25868.1.0.60
resetComplete
NOTIFICATION-TYPE
Reset Complete
1.3.6.1.4.1.25868.1.0.80
ethernetConnectionRestored
NOTIFICATION-TYPE
Ethernet Connection Restored
1.3.6.1.4.1.25868.1.0.99