Objects

NameOIDSyntaxAccessStatus
cpqRackInfo
OBJECT-IDENTITY
1.3.6.1.4.1.232.22
cpqRackMibRev
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.1
cpqRackMibRevMajor
OBJECT-TYPE
The major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.
1.3.6.1.4.1.232.22.1.1INTEGER (1..65535)read-onlymandatory
cpqRackMibRevMinor
OBJECT-TYPE
The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
1.3.6.1.4.1.232.22.1.2INTEGER (0..65535)read-onlymandatory
cpqRackMibCondition
OBJECT-TYPE
The overall condition. This object represents the overall status of the rack information represented by this MIB.
1.3.6.1.4.1.232.22.1.3INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackComponent
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2
cpqRackInterface
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.1
cpqRackOsCommon
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.1.4
cpqRackOsCommonPollFreq
OBJECT-TYPE
The Management Agent's polling frequency. The frequency, in seconds, at which the Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance.
1.3.6.1.4.1.232.22.2.1.4.1INTEGER (0..65535)read-writemandatory
cpqRackAsset
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.2
cpqRackAssetTable
OBJECT-TYPE
A table of rack asset information.
1.3.6.1.4.1.232.22.2.2.1not-accessiblemandatory
cpqRackAssetEntry
OBJECT-TYPE
A rack asset description.
1.3.6.1.4.1.232.22.2.2.1.1not-accessiblemandatory
cpqRackAssetIndex
OBJECT-TYPE
A number that uniquely specifies this rack table entry.
1.3.6.1.4.1.232.22.2.2.1.1.1INTEGERread-onlymandatory
cpqRackName
OBJECT-TYPE
The customer changeable identifier used to identify the entire rack. The string will be empty if the system does not report this function.
1.3.6.1.4.1.232.22.2.2.1.1.2DisplayString (SIZE(0..64))read-onlymandatory
cpqRackUid
OBJECT-TYPE
The rack unique identifier. The string will be empty if the rack does not report the UID or if it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.3DisplayString (SIZE(0..64))read-onlymandatory
cpqRackSerialNum
OBJECT-TYPE
The rack serial number. The string will be empty if the rack does not report the serial number.
1.3.6.1.4.1.232.22.2.2.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackTrapSequenceNum
OBJECT-TYPE
The trap sequence number for rack traps. This is used by the management application trap processing. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.5INTEGERread-onlymandatory
cpqRackHeight
OBJECT-TYPE
The internal height dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.6INTEGERread-onlymandatory
cpqRackWidth
OBJECT-TYPE
The internal width dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.7INTEGERread-onlymandatory
cpqRackDepth
OBJECT-TYPE
The internal depth dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.2.1.1.8INTEGERread-onlymandatory
cpqRackEnclosure
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.3
cpqRackCommonEnclosure
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.3.1
cpqRackCommonEnclosureTable
OBJECT-TYPE
A table of rack enclosure information.
1.3.6.1.4.1.232.22.2.3.1.1not-accessiblemandatory
cpqRackCommonEnclosureEntry
OBJECT-TYPE
A rack enclosure description.
1.3.6.1.4.1.232.22.2.3.1.1.1not-accessiblemandatory
cpqRackCommonEnclosureRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.1.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureIndex
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.1.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureModel
OBJECT-TYPE
The model name of the enclosure. The string will be empty if the enclosure does not report the model information.
1.3.6.1.4.1.232.22.2.3.1.1.1.3DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureAssetTag
OBJECT-TYPE
The customer changeable asset identifier of the enclosure. The string will be empty if the system does not report this function or if the asset tag has not been set.
1.3.6.1.4.1.232.22.2.3.1.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosurePartNumber
OBJECT-TYPE
The part number of the enclosure. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.3.1.1.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureSparePartNumber
OBJECT-TYPE
The spare part number of the enclosure. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.3.1.1.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.1.1.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFWRev
OBJECT-TYPE
The firmware revision of the enclosure. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
1.3.6.1.4.1.232.22.2.3.1.1.1.8DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.9DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureNeighborNamePrev
OBJECT-TYPE
The name of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure name could not be determined or there is no enclosure preceding this one.
1.3.6.1.4.1.232.22.2.3.1.1.1.10DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureNeighborNameNext
OBJECT-TYPE
The name of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure name could not be determined or there is no enclosure following this one.
1.3.6.1.4.1.232.22.2.3.1.1.1.11DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureHeight
OBJECT-TYPE
The height dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.12INTEGERread-onlymandatory
cpqRackCommonEnclosureWidth
OBJECT-TYPE
The width dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.13INTEGERread-onlymandatory
cpqRackCommonEnclosureDepth
OBJECT-TYPE
The depth dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.14INTEGERread-onlymandatory
cpqRackCommonEnclosureTrapSequenceNum
OBJECT-TYPE
The trap sequence number for the enclosure. This is used by the management application trap processing. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.15INTEGERread-onlymandatory
cpqRackCommonEnclosureCondition
OBJECT-TYPE
The overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. This value will be one of the following: other(1) No temperature sensors, fans, or fuses in the enclosure or the state could no be determined. ok(2) All temperature sensors, fans, and fuses are within the normal operating range. degraded(3) One or more temperature sensors, fans, or fuses are outside of the normal operating range. None are failed. failed(4) The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
1.3.6.1.4.1.232.22.2.3.1.1.1.16INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackCommonEnclosureHasServerBlades
OBJECT-TYPE
The enclosure can contain server blades. This will be true(2) is the enclosure can house server blades. The cpqRackServerEnclosureTable will contain server enclosure specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackServerEnclosureTable to get complete information on the server enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.17INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureHasPowerSupplies
OBJECT-TYPE
The enclosure can contain power supplies. This will be true(2) is the enclosure can house power supplies. The cpqRackEnclosurePowerTable will contain power enclosure specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackEnclosurePowerTable to get complete information on the power enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.18INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureHasNetConnectors
OBJECT-TYPE
The enclosure contains network connectivity. This will be true(2) is the enclosure contains network connectivity. The cpqRackCommonEnclosureNetConnectorTable will contain network connectivity specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete information on the network connector enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.19INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureHasTempSensors
OBJECT-TYPE
The enclosure contains temperature sensors. This will be true(2) is the enclosure contains temperature sensors. The cpqRackCommonEnclosureTempTable will contain temperature sensor specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureTempTable to get complete information on the enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.20INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureHasFans
OBJECT-TYPE
The enclosure contains fans. This will be true(2) is the enclosure contains fans. The cpqRackCommonEnclosureFanTable will contain the fan specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.21INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureHasFuses
OBJECT-TYPE
The enclosure contains fuses. This will be true(2) is the enclosure contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFuseTable to get complete information on the enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.22INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureMgmtUID
OBJECT-TYPE
The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. none(2) The LED is not present. Setting LED state is not allowed. ledOn(3) The LED is present and ON. The LED can be turned off by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4). ledOff(4) The LED is present and OFF. The LED can be turned on by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3).
1.3.6.1.4.1.232.22.2.3.1.1.1.23INTEGER {other(1), none(2), ledOn(3), ledOff(4)}read-writemandatory
cpqRackCommonEnclosureSerialNumPrev
OBJECT-TYPE
The serial number of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure serial number could not be determined or there is no enclosure preceding this one.
1.3.6.1.4.1.232.22.2.3.1.1.1.24DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureSerialNumNext
OBJECT-TYPE
The serial number of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure serial number could not be determined or there is no enclosure following this one.
1.3.6.1.4.1.232.22.2.3.1.1.1.25DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureAddress
OBJECT-TYPE
The unique address of the enclosure within the rack. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.1.1.26INTEGERread-onlymandatory
cpqRackCommonEnclosureProductId
OBJECT-TYPE
The product id string of the enclosure. The string will be empty if the enclosure does not report the product id string.
1.3.6.1.4.1.232.22.2.3.1.1.1.27DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureProductIdPrev
OBJECT-TYPE
The product id string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the product id string.
1.3.6.1.4.1.232.22.2.3.1.1.1.28DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureProductIdNext
OBJECT-TYPE
The product id string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the product id string.
1.3.6.1.4.1.232.22.2.3.1.1.1.29DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureUUID
OBJECT-TYPE
The universal unique identifier string of the enclosure. The string will be empty if the enclosure does not report the UUID string.
1.3.6.1.4.1.232.22.2.3.1.1.1.30DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureUUIDPrev
OBJECT-TYPE
The universal unique identifier string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the UUID string or if there is no preceding enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.31DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureUUIDNext
OBJECT-TYPE
The universal unique identifier string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the UUID string or if there is no following enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.32DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureHasManagers
OBJECT-TYPE
The enclosure contains managers. This will be true(2) is the enclosure contains managers. The cpqRackCommonEnclosureManagerTable will contain the manager specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureManagerTable to get complete information on the enclosure.
1.3.6.1.4.1.232.22.2.3.1.1.1.33INTEGER {false(1), true(2)}read-onlymandatory
cpqRackCommonEnclosureTempTable
OBJECT-TYPE
A table of rack enclosure temperature sensor information.
1.3.6.1.4.1.232.22.2.3.1.2not-accessiblemandatory
cpqRackCommonEnclosureTempEntry
OBJECT-TYPE
A rack enclosure temperature sensor description.
1.3.6.1.4.1.232.22.2.3.1.2.1not-accessiblemandatory
cpqRackCommonEnclosureTempRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureTempChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureTempSensorIndex
OBJECT-TYPE
A number that uniquely specifies this temperature sensor within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.2.1.3INTEGERread-onlymandatory
cpqRackCommonEnclosureTempSensorEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.2.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureTempLocation
OBJECT-TYPE
The location description of the temperature sensor within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.2.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureTempCurrent
OBJECT-TYPE
This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.3.1.2.1.6INTEGERread-onlymandatory
cpqRackCommonEnclosureTempThreshold
OBJECT-TYPE
This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackCommonEnclosureTempType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.3.1.2.1.7INTEGERread-onlymandatory
cpqRackCommonEnclosureTempCondition
OBJECT-TYPE
The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within the normal operating range. degraded(3) The temperature sensor is outside of the normal operating range. failed(4) The temperature sensor detects a condition that could possibly damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
1.3.6.1.4.1.232.22.2.3.1.2.1.8INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackCommonEnclosureTempType
OBJECT-TYPE
This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqRackCommonEnclosureTempCondition will be set to degraded(3) and the system will either continue or shutdown depending on the user preferences. critical(15) If a critical(15) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to failed(4) and the system will shutdown.
1.3.6.1.4.1.232.22.2.3.1.2.1.9INTEGER {other(1), blowout(5), caution(9), critical(15)}read-onlymandatory
cpqRackCommonEnclosureTempSensorEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure containing this temperature sensor. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.2.1.10DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFanTable
OBJECT-TYPE
A table of rack enclosure fan information.
1.3.6.1.4.1.232.22.2.3.1.3not-accessiblemandatory
cpqRackCommonEnclosureFanEntry
OBJECT-TYPE
A rack enclosure fan description.
1.3.6.1.4.1.232.22.2.3.1.3.1not-accessiblemandatory
cpqRackCommonEnclosureFanRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureFanChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureFanIndex
OBJECT-TYPE
A number that uniquely specifies this fan within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.3.1.3INTEGERread-onlymandatory
cpqRackCommonEnclosureFanEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFanLocation
OBJECT-TYPE
The location description of the fan within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFanPartNumber
OBJECT-TYPE
The part number of the enclosure fan. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFanSparePartNumber
OBJECT-TYPE
The spare part number of the enclosure fan. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFanPresent
OBJECT-TYPE
This specifies if the fan described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.3.1.8INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackCommonEnclosureFanRedundant
OBJECT-TYPE
This specifies if the fan is in a redundant configuration.
1.3.6.1.4.1.232.22.2.3.1.3.1.9INTEGER {other(1), notRedundant(2), redundant(3)}read-onlymandatory
cpqRackCommonEnclosureFanRedundantGroupId
OBJECT-TYPE
This specifies the group number for redundant fans within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.3.1.10INTEGERread-onlymandatory
cpqRackCommonEnclosureFanCondition
OBJECT-TYPE
The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported. ok(2) The fan is operating properly. degraded(2) A redundant fan is not operating properly. failed(4) A non-redundant fan is not operating properly.
1.3.6.1.4.1.232.22.2.3.1.3.1.11INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackCommonEnclosureFanEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure containing the fan. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.3.1.12DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFuseTable
OBJECT-TYPE
A table of rack enclosure fuse information.
1.3.6.1.4.1.232.22.2.3.1.4not-accessiblemandatory
cpqRackCommonEnclosureFuseEntry
OBJECT-TYPE
A rack enclosure fuse description.
1.3.6.1.4.1.232.22.2.3.1.4.1not-accessiblemandatory
cpqRackCommonEnclosureFuseRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.4.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureFuseChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.4.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureFuseIndex
OBJECT-TYPE
A number that uniquely specifies the fuse within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.4.1.3INTEGERread-onlymandatory
cpqRackCommonEnclosureFuseEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.4.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFuseLocation
OBJECT-TYPE
The location description of the fuse within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.4.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFusePresent
OBJECT-TYPE
This specifies if the fuse described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.4.1.6INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackCommonEnclosureFuseCondition
OBJECT-TYPE
The condition of the fuse. This value will be one of the following: other(1) Fuse status detection is not supported. ok(2) The fuse is operating properly. failed(4) A fuse has been tripped or is not operating properly.
1.3.6.1.4.1.232.22.2.3.1.4.1.7INTEGER {other(1), ok(2), failed(4)}read-onlymandatory
cpqRackCommonEnclosureFruTable
OBJECT-TYPE
A table of rack enclosure field replaceable units information.
1.3.6.1.4.1.232.22.2.3.1.5not-accessiblemandatory
cpqRackCommonEnclosureFruEntry
OBJECT-TYPE
A rack enclosure field replaceable unit description.
1.3.6.1.4.1.232.22.2.3.1.5.1not-accessiblemandatory
cpqRackCommonEnclosureFruRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.5.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureFruChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.5.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureFruIndex
OBJECT-TYPE
A number that uniquely specifies the FRU within this enclosure.
1.3.6.1.4.1.232.22.2.3.1.5.1.3INTEGERread-onlymandatory
cpqRackCommonEnclosureFruEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.5.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruDescription
OBJECT-TYPE
A description of the FRU component. The string will be empty if the enclosure does not report the description information.
1.3.6.1.4.1.232.22.2.3.1.5.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruLocation
OBJECT-TYPE
The location description of the FRU within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.5.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruAssemblyPartNumber
OBJECT-TYPE
The assembly part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruSparePartNumber
OBJECT-TYPE
The spare part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.8DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruAutoRev
OBJECT-TYPE
The auto revision number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
1.3.6.1.4.1.232.22.2.3.1.5.1.9DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureFruSerialNum
OBJECT-TYPE
The serial number of the FRU within the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.1.5.1.10DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerTable
OBJECT-TYPE
A table of rack enclosure manager information.
1.3.6.1.4.1.232.22.2.3.1.6not-accessiblemandatory
cpqRackCommonEnclosureManagerEntry
OBJECT-TYPE
A rack enclosure manager description.
1.3.6.1.4.1.232.22.2.3.1.6.1not-accessiblemandatory
cpqRackCommonEnclosureManagerRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.1INTEGERread-onlymandatory
cpqRackCommonEnclosureManagerChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.2INTEGERread-onlymandatory
cpqRackCommonEnclosureManagerIndex
OBJECT-TYPE
A number that uniquely specifies this manager within this enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.1.6.1.3INTEGERread-onlymandatory
cpqRackCommonEnclosureManagerEnclosureName
OBJECT-TYPE
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerLocation
OBJECT-TYPE
The location description of the manager within the enclosure. The string will be empty if the location could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerPartNumber
OBJECT-TYPE
The part number of the enclosure manager. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerSparePartNumber
OBJECT-TYPE
The spare part number of the enclosure manager. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerSerialNum
OBJECT-TYPE
The serial number of the enclosure manager. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.8DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerRole
OBJECT-TYPE
This specifies the current role of the manager.
1.3.6.1.4.1.232.22.2.3.1.6.1.9INTEGER {standby(1), active(2)}read-onlymandatory
cpqRackCommonEnclosureManagerPresent
OBJECT-TYPE
This specifies if the manager described is present in the system.
1.3.6.1.4.1.232.22.2.3.1.6.1.10INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackCommonEnclosureManagerRedundant
OBJECT-TYPE
This specifies if the manager is in a redundant configuration.
1.3.6.1.4.1.232.22.2.3.1.6.1.11INTEGER {other(1), notRedundant(2), redundant(3)}read-onlymandatory
cpqRackCommonEnclosureManagerCondition
OBJECT-TYPE
The condition of the manager. This value will be one of the following: other(1) Manager status detection is not supported. ok(2) The manager is operating properly. degraded(2) A redundant manager is not operating properly. failed(4) A non-redundant manager is not operating properly.
1.3.6.1.4.1.232.22.2.3.1.6.1.12INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackCommonEnclosureManagerEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure containing the manager. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.3.1.6.1.13DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerUUID
OBJECT-TYPE
The universal unique identifier string of the manager. The string will be empty if the enclosure does not report the UUID string.
1.3.6.1.4.1.232.22.2.3.1.6.1.14DisplayString (SIZE(0..64))read-onlymandatory
cpqRackCommonEnclosureManagerFWRev
OBJECT-TYPE
The firmware revision of the enclosure manager. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
1.3.6.1.4.1.232.22.2.3.1.6.1.15DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerEnclosure
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.3.2
cpqRackServerEnclosureTable
OBJECT-TYPE
A table of rack enclosure information for servers.
1.3.6.1.4.1.232.22.2.3.2.1not-accessiblemandatory
cpqRackServerEnclosureEntry
OBJECT-TYPE
A server enclosure description.
1.3.6.1.4.1.232.22.2.3.2.1.1not-accessiblemandatory
cpqRackServerEnclosureRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.2.1.1.1INTEGERread-onlymandatory
cpqRackServerEnclosureIndex
OBJECT-TYPE
A number that uniquely specifies this server enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.2.1.1.2INTEGERread-onlymandatory
cpqRackServerEnclosureName
OBJECT-TYPE
The name of the server enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.2.1.1.3DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerEnclosureMaxNumBlades
OBJECT-TYPE
The maximum number of server blades the enclosure can contain. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.2.1.1.4INTEGERread-onlymandatory
cpqRackServerEnclosureMaxNumBladesX
OBJECT-TYPE
The maximum number of server blades in x-direction (from left to right) the enclosure can contain.
1.3.6.1.4.1.232.22.2.3.2.1.1.5INTEGERread-onlymandatory
cpqRackServerEnclosureMaxNumBladesY
OBJECT-TYPE
The maximum number of server blades in y-direction (from top to bottom) the enclosure can contain.
1.3.6.1.4.1.232.22.2.3.2.1.1.6INTEGERread-onlymandatory
cpqRackServerEnclosureSolutionsId
OBJECT-TYPE
The identifier is used to label enclosure as a BladeSystem Matrix enclosure. Octet Values ===== ============================== 1 Solutions platform identifier Bits[7:4] - 0001b BladeSystem Matrix configured - 0000b reserved Bits[3:0] - 0000b reserved 2 major number - 0x01 - 0xff 3 minor number - 0x01 - 0xff 4 update number - 0x01 - 0xff 5 reserved/unused The identifier is set to all 0's if the enclosure is not configured as a BladeSystem Matrix enclosure.
1.3.6.1.4.1.232.22.2.3.2.1.1.7OCTET STRING (SIZE(8))read-writeoptional
cpqRackLastEAEEvent
OBJECT-TYPE
Data for the last EAE event.
1.3.6.1.4.1.232.22.2.3.2.2DisplayString (SIZE(0..512))read-onlyoptional
cpqRackPowerEnclosure
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.3.3
cpqRackPowerEnclosureTable
OBJECT-TYPE
A table of rack power enclosure information.
1.3.6.1.4.1.232.22.2.3.3.1not-accessiblemandatory
cpqRackPowerEnclosureEntry
OBJECT-TYPE
A rack power enclosure description.
1.3.6.1.4.1.232.22.2.3.3.1.1not-accessiblemandatory
cpqRackPowerEnclosureRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.3.3.1.1.1INTEGERread-onlymandatory
cpqRackPowerEnclosureIndex
OBJECT-TYPE
A number that uniquely specifies this power enclosure in the rack.
1.3.6.1.4.1.232.22.2.3.3.1.1.2INTEGERread-onlymandatory
cpqRackPowerEnclosureName
OBJECT-TYPE
The name of the power enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.3.3.1.1.3DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerEnclosureMgmtBoardSerialNum
OBJECT-TYPE
The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
1.3.6.1.4.1.232.22.2.3.3.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerEnclosureRedundant
OBJECT-TYPE
This indicates if the power supply enclosure is in a redundant state.
1.3.6.1.4.1.232.22.2.3.3.1.1.5INTEGER {other(1), notRedundant(2), redundant(3)}read-onlymandatory
cpqRackPowerEnclosureLoadBalanced
OBJECT-TYPE
This indicates if the power supply enclosure is in a load balanced state.
1.3.6.1.4.1.232.22.2.3.3.1.1.6INTEGER {other(1), notLoadBalanced(2), loadBalanced(3)}read-onlymandatory
cpqRackPowerEnclosureInputPwrType
OBJECT-TYPE
This indicates type of input facility power.
1.3.6.1.4.1.232.22.2.3.3.1.1.7INTEGER {other(1), singlePhase(2), threePhase(3), directCurrent(4)}read-onlymandatory
cpqRackPowerEnclosurePwrFeedMax
OBJECT-TYPE
This is the maximum facility power in watts. The maximum facility power being fed to this power enclosure. The value will be -1 if the power enclosure does not report the value or if the value is not known.
1.3.6.1.4.1.232.22.2.3.3.1.1.8INTEGERread-onlymandatory
cpqRackPowerEnclosureCondition
OBJECT-TYPE
This indicates current condition of the power enclosure. other(1) The power enclosure condition could not be determined. ok(2) The power enclosure is operating normally. degraded(3) The power enclosure is in a degraded state. The power subsystem may not be load balanced or may have lost redundancy.
1.3.6.1.4.1.232.22.2.3.3.1.1.9INTEGER {other(1), ok(2), degraded(3)}read-onlymandatory
cpqRackPowerEnclosureBladeAutopoweron
OBJECT-TYPE
This indicates current condition of the power enclosure. other(1) The blade auto power on feature could not be determined. disabled(2) The enclosure will not automatically power on a blade when inserted. enabled(3) The enclosure will automatically power on a blade when inserted.
1.3.6.1.4.1.232.22.2.3.3.1.1.10INTEGER {other(1), disabled(2), enabled(3)}read-writeoptional
cpqRackServer
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.4
cpqRackServerBlade
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.4.1
cpqRackServerBladeTable
OBJECT-TYPE
A table of rack server blade information.
1.3.6.1.4.1.232.22.2.4.1.1not-accessiblemandatory
cpqRackServerBladeEntry
OBJECT-TYPE
A rack server blade description.
1.3.6.1.4.1.232.22.2.4.1.1.1not-accessiblemandatory
cpqRackServerBladeRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.1.1.1.1INTEGERread-onlymandatory
cpqRackServerBladeChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.1.1.1.2INTEGERread-onlymandatory
cpqRackServerBladeIndex
OBJECT-TYPE
A number that uniquely specifies this server blade within the enclosure.
1.3.6.1.4.1.232.22.2.4.1.1.1.3INTEGERread-onlymandatory
cpqRackServerBladeName
OBJECT-TYPE
The name of the server blade. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeEnclosureName
OBJECT-TYPE
The name of the enclosure which contains the blade. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladePartNumber
OBJECT-TYPE
The part number of the server blade. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeSparePartNumber
OBJECT-TYPE
The spare part number of the server blade. The string will be empty if the part number could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladePosition
OBJECT-TYPE
The position or slot number of the server blade within the server enclosure. This will be -1 if the server enclosure does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.8INTEGERread-onlymandatory
cpqRackServerBladeHeight
OBJECT-TYPE
The height dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.9INTEGERread-onlymandatory
cpqRackServerBladeWidth
OBJECT-TYPE
The width dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.10INTEGERread-onlymandatory
cpqRackServerBladeDepth
OBJECT-TYPE
The depth dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.11INTEGERread-onlymandatory
cpqRackServerBladePresent
OBJECT-TYPE
This specifies if the server blade described is present in the enclosure.
1.3.6.1.4.1.232.22.2.4.1.1.1.12INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackServerBladeHasFuses
OBJECT-TYPE
The server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackServerBladeEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the fuses.
1.3.6.1.4.1.232.22.2.4.1.1.1.13INTEGER {false(1), true(2)}read-onlymandatory
cpqRackServerBladeEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure which contains the blade. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.14DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeSlotsUsed
OBJECT-TYPE
The number of slot positions occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.15INTEGERread-onlymandatory
cpqRackServerBladeSerialNum
OBJECT-TYPE
The serial number of the server blade. The string will be empty if the system does not report the serial number function.
1.3.6.1.4.1.232.22.2.4.1.1.1.16DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeProductId
OBJECT-TYPE
The product id string of the server blade. The string will be empty if the system does not report the product id function.
1.3.6.1.4.1.232.22.2.4.1.1.1.17DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeUid
OBJECT-TYPE
The server blade unique identifier (UUID). The string will be empty if the blade does not report the UUID or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.18DisplayString (SIZE(0..64))read-onlymandatory
cpqRackServerBladeSlotsUsedX
OBJECT-TYPE
The number of slot positions in x-direction (from left to right) occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.19INTEGERread-onlymandatory
cpqRackServerBladeSlotsUsedY
OBJECT-TYPE
The number of slot positions in y-direction (from top to bottom) occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.20INTEGERread-onlymandatory
cpqRackServerBladeStatus
OBJECT-TYPE
The health status of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.21INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlyoptional
cpqRackServerBladeFaultMajor
OBJECT-TYPE
The major fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.22INTEGERread-onlyoptional
cpqRackServerBladeFaultMinor
OBJECT-TYPE
The minor fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.23INTEGERread-onlyoptional
cpqRackServerBladeFaultDiagnosticString
OBJECT-TYPE
The server blade fault diagnostic string. This will contain a probable cause and potential diagnostic action to be taken to remedy the fault condition. The string will be empty if the blade does not report the diagnostic string or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.24DisplayString (SIZE(0..128))read-onlyoptional
cpqRackServerBladePowered
OBJECT-TYPE
The power state of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.25INTEGER {other(1), on(2), off(3), powerStagedOff(4), reboot(5)}read-writeoptional
cpqRackServerBladeUIDState
OBJECT-TYPE
The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. none(2) The LED is not present. Setting LED state is not allowed. ledOn(3) The LED is present and ON. The LED can be turned off by setting the cpqRackServerBladeUIDState to ledOff(4). ledOff(4) The LED is present and OFF. The LED can be turned on by setting the cpqRackServerBladeUIDState to ledOn(3).
1.3.6.1.4.1.232.22.2.4.1.1.1.26INTEGER {other(1), none(2), ledOn(3), ledOff(4)}read-writeoptional
cpqRackServerBladeSystemBIOSRevision
OBJECT-TYPE
The server blade system bios revision. The string will be empty if the blade does not report the system bios revision or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.27DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerBladeSystemBIOSFlashingStatus
OBJECT-TYPE
Blade server system BIOS flashing / flash mode status indication. This will be other(1) if the rack does not report the information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.28INTEGER {other(1), normal(2), flashing(3)}read-onlyoptional
cpqRackServerBladeHasManagementDevice
OBJECT-TYPE
The blade server contains one or more management devices. This will be true(2) if the blade server contains managers and false (1) if not or if it can't be detected.
1.3.6.1.4.1.232.22.2.4.1.1.1.29INTEGER {false(1), true(2)}read-onlyoptional
cpqRackServerBladeManagementDeviceFirmwareRevision
OBJECT-TYPE
The server blade management device firwmware revision. The string will be empty if the blade does not report the management device firwmware revision or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.30DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus
OBJECT-TYPE
Blade server management device firwmware flashing / flash mode status indication. This will be other(1) if the rack does not report this information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.31INTEGER {other(1), normal(2), flashing(3)}read-onlyoptional
cpqRackServerBladeDiagnosticAdaptorPresence
OBJECT-TYPE
This specifies if a blade diagnostic adaptor is currently plugged into the system.
1.3.6.1.4.1.232.22.2.4.1.1.1.32INTEGER {other(1), absent(2), present(3)}read-onlyoptional
cpqRackServerBladeASREnabled
OBJECT-TYPE
Indicates whether the target blade server has Automatic Service Recovery feature enabled. This will be true(2) if the blade server has this feature eanbled and false (1) if not or if it can't be detected.
1.3.6.1.4.1.232.22.2.4.1.1.1.33INTEGER {false(1), true(2)}read-onlyoptional
cpqRackServerBladeFrontIOBlankingModeStatus
OBJECT-TYPE
Indicates whether the target blade server has the front IO ports blanking feature enabled. This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not, or Unknown(1) if it can't be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.34INTEGER {unknown(1), inactive(2), active(3)}read-onlyoptional
cpqRackServerBladePOSTStatus
OBJECT-TYPE
Blade server power-on self test (POST) status. This value will be one of the following: other(1) The state of the blade POST could not be determined. started(2) Blade has started Power-on-self-test (POST) process. completed(3) Blade has finished Power-on-self-test (POST) process. failed(4) Blade has failed to complete Power-on-self-test (POST) process and halted. This will be other(1) if the rack does not report this information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.35INTEGER {other(1), started(2), completed(3), failed(4)}read-onlyoptional
cpqRackServerBladePXEBootModeStatus
OBJECT-TYPE
Indicates whether the target blade server is in PXE boot mode. This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not, or Unknown(1) if it can't be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.36INTEGER {unknown(1), inactive(2), active(3)}read-onlyoptional
cpqRackServerBladePendingBootOrderChange
OBJECT-TYPE
Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First firstHDD(4) - First Boot To Local HD firstRBSU(5) - First Boot To ROM Based Setup Utility oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once onceHDD(7) - Boot To Local HD Once onceRBSU(8) - Boot To ROM Based Setup Utility Once alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE) alwaysHDD(10) - Always Boot To Local HD alwaysRBSU(11) - Always Boot To ROM Based Setup Utility This will be other(1) if the rack does not report this information or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.1.1.1.37INTEGER {other(1), none(2), firstPXE(3), firstHDD(4), firstRBSU(5), oncePXE(6), onceHDD(7), onceRBSU(8), alwaysPXE(9), alwaysHDD(10), alwaysRBSU(11)}read-writeoptional
cpqRackServerBladeWattageMax
OBJECT-TYPE
Maximum wattage the server has consumed during this power cycle.
1.3.6.1.4.1.232.22.2.4.1.1.1.38INTEGERread-onlyoptional
cpqRackServerBladeWattageAvg
OBJECT-TYPE
Average wattage the server is consuming, averaged over a period defined by the product.
1.3.6.1.4.1.232.22.2.4.1.1.1.39INTEGERread-onlyoptional
cpqRackServerBladeWattageMin
OBJECT-TYPE
Minimum wattage the server has consumed, computed from a period defined by the product. Value will be 0 if not supported, but other wattage values are supported.
1.3.6.1.4.1.232.22.2.4.1.1.1.40INTEGERread-onlyoptional
cpqRackServerNetworking
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.4.2
cpqRackServerNetworkingTable
OBJECT-TYPE
A table of rack server networking information.
1.3.6.1.4.1.232.22.2.4.2.1not-accessibleoptional
cpqRackServerNetworkingEntry
OBJECT-TYPE
A rack server networking description.
1.3.6.1.4.1.232.22.2.4.2.1.1not-accessibleoptional
cpqRackServerNetworkingRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.2.1.1.1INTEGERread-onlyoptional
cpqRackServerNetworkingChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.2.1.1.2INTEGERread-onlymandatory
cpqRackServerNetworkingIndex
OBJECT-TYPE
A number that uniquely specifies this server within the enclosure.
1.3.6.1.4.1.232.22.2.4.2.1.1.3INTEGERread-onlyoptional
cpqRackServerNetworkingName
OBJECT-TYPE
The name of the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.2.1.1.4DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerNetworkingEnclosureName
OBJECT-TYPE
The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.2.1.1.5DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerNetworkingEthernetInterfaces
OBJECT-TYPE
A number that specifies the amount of Ethernet network interfaces in the server.
1.3.6.1.4.1.232.22.2.4.2.1.1.6INTEGERread-onlyoptional
cpqRackServerNetworkingEthernetMACAddress
OBJECT-TYPE
The MAC address for the Ethernet NIC populated in the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.2.1.1.7DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerTempSensor
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.4.3
cpqRackServerTempSensorTable
OBJECT-TYPE
A table of rack server temperature sensor information.
1.3.6.1.4.1.232.22.2.4.3.1not-accessibleoptional
cpqRackServerTempSensorEntry
OBJECT-TYPE
A rack server temperature sensor description.
1.3.6.1.4.1.232.22.2.4.3.1.1not-accessibleoptional
cpqRackServerTempSensorRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.4.3.1.1.1INTEGERread-onlyoptional
cpqRackServerTempSensorChassis
OBJECT-TYPE
A number that uniquely specifies this enclosure in the rack.
1.3.6.1.4.1.232.22.2.4.3.1.1.2INTEGERread-onlyoptional
cpqRackServerTempSensorIndex
OBJECT-TYPE
A number that uniquely specifies this server within the enclosure.
1.3.6.1.4.1.232.22.2.4.3.1.1.3INTEGERread-onlyoptional
cpqRackServerTempSensorName
OBJECT-TYPE
The name of the server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.4DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerTempSensorEnclosureName
OBJECT-TYPE
The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.5DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerTempSensorCount
OBJECT-TYPE
A number that specifies the amount of temperature sensors in the server.
1.3.6.1.4.1.232.22.2.4.3.1.1.6INTEGERread-onlyoptional
cpqRackServerTempSensorLocation
OBJECT-TYPE
The location description of the temperature sensor within the blade server. The string will be empty if it could not be determined.
1.3.6.1.4.1.232.22.2.4.3.1.1.7DisplayString (SIZE(0..64))read-onlyoptional
cpqRackServerTempSensorCurrent
OBJECT-TYPE
This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.4.3.1.1.8INTEGERread-onlyoptional
cpqRackServerTempSensorThreshold
OBJECT-TYPE
This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackServerTempSensorType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.
1.3.6.1.4.1.232.22.2.4.3.1.1.9INTEGERread-onlyoptional
cpqRackServerTempSensorCondition
OBJECT-TYPE
The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within the normal operating range. degraded(3) The temperature sensor is outside of the normal operating range. failed(4) The temperature sensor detects a condition that could possibly overheat the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
1.3.6.1.4.1.232.22.2.4.3.1.1.10INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlyoptional
cpqRackServerTempSensorType
OBJECT-TYPE
This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqRackServerTempSensorCondition will be set to degraded(3) and the system will either continue or shutdown depending on the local blade server policy settings. critical(15) If a critical(15) temperature sensor reaches its threshold, cpqRackServerTempSensorCondition will be set to failed(4) and the blade server will shutdown.
1.3.6.1.4.1.232.22.2.4.3.1.1.11INTEGER {other(1), blowout(5), caution(9), critical(15)}read-onlyoptional
cpqRackPower
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.5
cpqRackPowerSupply
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.5.1
cpqRackPowerSupplyTable
OBJECT-TYPE
A table of rack power supply information.
1.3.6.1.4.1.232.22.2.5.1.1not-accessiblemandatory
cpqRackPowerSupplyEntry
OBJECT-TYPE
A rack power supply description.
1.3.6.1.4.1.232.22.2.5.1.1.1not-accessiblemandatory
cpqRackPowerSupplyRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.5.1.1.1.1INTEGERread-onlymandatory
cpqRackPowerSupplyChassis
OBJECT-TYPE
A number that uniquely specifies this power enclosure in the rack.
1.3.6.1.4.1.232.22.2.5.1.1.1.2INTEGERread-onlymandatory
cpqRackPowerSupplyIndex
OBJECT-TYPE
A number that uniquely specifies this power supply in the enclosure.
1.3.6.1.4.1.232.22.2.5.1.1.1.3INTEGERread-onlymandatory
cpqRackPowerSupplyEnclosureName
OBJECT-TYPE
The name of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerSupplySerialNum
OBJECT-TYPE
The serial number of the power supply. The string will be empty if the power supply does not report the serial number.
1.3.6.1.4.1.232.22.2.5.1.1.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerSupplyPartNumber
OBJECT-TYPE
The part number of the power supply. The string will be empty if the power supply does not report this function.
1.3.6.1.4.1.232.22.2.5.1.1.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerSupplySparePartNumber
OBJECT-TYPE
The spare part number of the power supply. The string will be empty if the power supply does not report this function.
1.3.6.1.4.1.232.22.2.5.1.1.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerSupplyFWRev
OBJECT-TYPE
The firmware revision of the power supply. The string will be empty if the power supply does not report the firmware revision.
1.3.6.1.4.1.232.22.2.5.1.1.1.8DisplayString (SIZE(0..64))read-onlymandatory
cpqRackPowerSupplyMaxPwrOutput
OBJECT-TYPE
The maximum power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.9INTEGERread-onlymandatory
cpqRackPowerSupplyCurPwrOutput
OBJECT-TYPE
The current power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.10INTEGERread-onlymandatory
cpqRackPowerSupplyPosition
OBJECT-TYPE
The position of the power supply within the power enclosure. This will be -1 if the power enclosure does not report the power supply information or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.11INTEGERread-onlymandatory
cpqRackPowerSupplyIntakeTemp
OBJECT-TYPE
The current air temperature at the intake of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.12INTEGERread-onlymandatory
cpqRackPowerSupplyExhaustTemp
OBJECT-TYPE
The current air temperature at the exhaust of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
1.3.6.1.4.1.232.22.2.5.1.1.1.13INTEGERread-onlymandatory
cpqRackPowerSupplyStatus
OBJECT-TYPE
The status of the power supply.
1.3.6.1.4.1.232.22.2.5.1.1.1.14INTEGER {noError(1), generalFailure(2), bistFailure(3), fanFailure(4), tempFailure(5), interlockOpen(6), epromFailed(7), vrefFailed(8), dacFailed(9), ramTestFailed(10), voltageChannelFailed(11), orringdiodeFailed(12), brownOut(13), giveupOnStartup(14), nvramInvalid(15), calibrationTableInvalid(16)}read-onlymandatory
cpqRackPowerSupplyInputLineStatus
OBJECT-TYPE
The status of line input power.
1.3.6.1.4.1.232.22.2.5.1.1.1.15INTEGER {noError(1), lineOverVoltage(2), lineUnderVoltage(3), lineHit(4), brownOut(5), linePowerLoss(6)}read-onlymandatory
cpqRackPowerSupplyPresent
OBJECT-TYPE
This specifies if the power supply described is present in the enclosure.
1.3.6.1.4.1.232.22.2.5.1.1.1.16INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackPowerSupplyCondition
OBJECT-TYPE
The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply is operating normally. degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) A power supply component detects a condition that could possibly damage the system.
1.3.6.1.4.1.232.22.2.5.1.1.1.17INTEGER {other(1), ok(2), degraded(3), failed(4)}read-onlymandatory
cpqRackPowerSupplyEnclosureSerialNum
OBJECT-TYPE
The serial number of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.5.1.1.1.18DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.6
cpqRackNetConnector
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.6.1
cpqRackNetConnectorTable
OBJECT-TYPE
A table of rack network connector information.
1.3.6.1.4.1.232.22.2.6.1.1not-accessiblemandatory
cpqRackNetConnectorEntry
OBJECT-TYPE
A rack network connector description.
1.3.6.1.4.1.232.22.2.6.1.1.1not-accessiblemandatory
cpqRackNetConnectorRack
OBJECT-TYPE
A number that uniquely specifies this rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.1INTEGERread-onlymandatory
cpqRackNetConnectorChassis
OBJECT-TYPE
A number that uniquely specifies this server enclosure in the rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.2INTEGERread-onlymandatory
cpqRackNetConnectorIndex
OBJECT-TYPE
A number that uniquely specifies this network connector in the rack.
1.3.6.1.4.1.232.22.2.6.1.1.1.3INTEGERread-onlymandatory
cpqRackNetConnectorEnclosureName
OBJECT-TYPE
The name of the network connector enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.6.1.1.1.4DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorName
OBJECT-TYPE
The name of the network connector. The string will be empty if the network connector does not report the name or it could not be determined.
1.3.6.1.4.1.232.22.2.6.1.1.1.5DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorModel
OBJECT-TYPE
The model name of the network connector. The string will be empty if the network connector does not report the model information.
1.3.6.1.4.1.232.22.2.6.1.1.1.6DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorSerialNum
OBJECT-TYPE
The serial number of the network connector. The string will be empty if the network connector does not report the serial number.
1.3.6.1.4.1.232.22.2.6.1.1.1.7DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorPartNumber
OBJECT-TYPE
The part number of the network connector. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.6.1.1.1.8DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorSparePartNumber
OBJECT-TYPE
The spare part number of the network connector. The string will be empty if the enclosure does not report this function.
1.3.6.1.4.1.232.22.2.6.1.1.1.9DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorFWRev
OBJECT-TYPE
The firmware revision of the network connector. The string will be empty if the network connector does not report the firmware revision.
1.3.6.1.4.1.232.22.2.6.1.1.1.10DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorType
OBJECT-TYPE
The type of network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.11INTEGER {other(1), passive(2), active(3)}read-onlymandatory
cpqRackNetConnectorLocation
OBJECT-TYPE
The location of the network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.12DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorPresent
OBJECT-TYPE
This specifies if the network connector described is present in the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.13INTEGER {other(1), absent(2), present(3)}read-onlymandatory
cpqRackNetConnectorHasFuses
OBJECT-TYPE
The network connector contains fuses. This will be true(2) is the network connector contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackNetworkEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFusTable to get complete information on the fuses.
1.3.6.1.4.1.232.22.2.6.1.1.1.14INTEGER {false(1), true(2)}read-onlymandatory
cpqRackNetConnectorEnclosureSerialNum
OBJECT-TYPE
The serial number of the enclosure containing the network connector. The string will be empty if the enclosure does not report the serial number or it could not be determined.
1.3.6.1.4.1.232.22.2.6.1.1.1.15DisplayString (SIZE(0..64))read-onlymandatory
cpqRackNetConnectorTechnologyType
OBJECT-TYPE
The type of network connector within the enclosure.
1.3.6.1.4.1.232.22.2.6.1.1.1.16INTEGER {other(1), passive(2), active(3)}read-onlymandatory
cpqRackNetConnectorDeviceType
OBJECT-TYPE
The type of interrconnect in the enclosure. This will be -1 if it is not reported or can not be deteremined.
1.3.6.1.4.1.232.22.2.6.1.1.1.17INTEGER {noconnect(1), network(2), fibrechannel(3), sas(4), inifiband(5), pciexpress(6)}read-onlymandatory
cpqRackNetworkAddressesTable
OBJECT-TYPE
A table of rack network addresses.
1.3.6.1.4.1.232.22.2.6.2not-accessiblemandatory
cpqRackNetworkAddressesEntry
OBJECT-TYPE
Array of ALL the network addresses of the system generating the indication. This may include IPv4 addresses (based on IETF RFC 1208) or IPv6 addresses (based on IETF RFC 4291).
1.3.6.1.4.1.232.22.2.6.2.1not-accessiblemandatory
cpqRackNetworkAddresses
OBJECT-TYPE
A network address of the system generating the indication.
1.3.6.1.4.1.232.22.2.6.2.1.1DisplayString (SIZE(0..50))read-onlymandatory
cpqRackHW
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.7
cpqRackHWPartNumber
OBJECT-TYPE
Part number for the hardware generating the indication.
1.3.6.1.4.1.232.22.2.7.1DisplayString (SIZE(0..16))read-onlyoptional
cpqRackHWFirmwareVersionTable
OBJECT-TYPE
A table of rack firmware versions.
1.3.6.1.4.1.232.22.2.7.2not-accessibleoptional
cpqRackHWFirmwareVersionEntry
OBJECT-TYPE
Array of versions of firmware for the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.2.1not-accessibleoptional
cpqRackHWFirmwareVersion
OBJECT-TYPE
A version of firmware for the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.2.1.1DisplayString (SIZE(0..30))read-onlyoptional
cpqRackHWManufacturer
OBJECT-TYPE
Manufacturer of the hardware associated with the indication.Device indication hardware manufacturer.
1.3.6.1.4.1.232.22.2.7.3DisplayString (SIZE(0..65))read-onlyoptional
cpqRackHWSerialNumberTable
OBJECT-TYPE
A table of rack hardware serial numbers.
1.3.6.1.4.1.232.22.2.7.4not-accessibleoptional
cpqRackHWSerialNumberEntry
OBJECT-TYPE
Array of all the serial numbers of the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.4.1not-accessibleoptional
cpqRackHWSerialNumber
OBJECT-TYPE
A serial number of the hardware associated with the indication.
1.3.6.1.4.1.232.22.2.7.4.1.1DisplayString (SIZE(0..21))read-onlyoptional
cpqRackHWFRUDetails
OBJECT-TYPE
This is used to provide miscellaneous FRU specific details Some examples are DIMM size, Processor stepping info etc.
1.3.6.1.4.1.232.22.2.7.5OCTET STRING (SIZE(0..256))read-onlyoptional
cpqRackHWDevicePermanentNameFormat
OBJECT-TYPE
The format of the DevicePermanentName property is interpreted based upon the value of this property. Values are defined as: 1 - unknown. The format is not meaningfully interpretable by a CIM client application. 2 - other. The format is defined by the value of the OtherPermanentNameFormat property. 3 - worldWideName. The format is a WorldWideName. 4 - macAddress. The format is a LAN MAC Address.
1.3.6.1.4.1.232.22.2.7.6INTEGER {unknown(1), other(2), worldWideName(3), macAddress(4)}read-onlyoptional
cpqRackHWOtherPermanentNameFormat
OBJECT-TYPE
A string defining other values for DevicePermanentFormat. It is empty unless DevicePermanentFormat value is other.
1.3.6.1.4.1.232.22.2.7.7DisplayString (SIZE(0..64))read-onlyoptional
cpqRackErs
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.2.8
cpqRackErsTransactionType
OBJECT-TYPE
Embedded Remote Support transaction type. The following values are defined: registration(1) Registration operation with Insight Remote Host or Insight Online Host. serviceEvent(2) Sending of service event to Insight Remote Host or Insight Online Host. l2DataCollection(3) L2 Data collection operation. unregistration(4) Unregistration with Insight Remote Host or Insight Online Host.
1.3.6.1.4.1.232.22.2.8.1INTEGER {registration(1), serviceEvent(2), l2DataCollection(3), unregistration(4)}read-onlymandatory
cpqRackErsConnectionModel
OBJECT-TYPE
Embedded Remote Support connection model configured on the Onboard Administrator.
1.3.6.1.4.1.232.22.2.8.2INTEGER {insightOnline(1), insightRemoteSupport(2)}read-onlymandatory
cpqRackErsFailureCode
OBJECT-TYPE
Embedded Remote Support transaction failure code.
1.3.6.1.4.1.232.22.2.8.3INTEGER {genericTransmitError(1), clientTransmitTimeout(2), clientReceiveTimeout(3), proxyConnectError(4), remoteHostConnectError(5), remoteServiceError(6)}read-onlymandatory
cpqRackErsRemoteHost
OBJECT-TYPE
Remote destination server's hostname and port as configured on the Onboard Administrator. Example: myremotehost.hpe.com:6789
1.3.6.1.4.1.232.22.2.8.4DisplayString (SIZE(0..135))read-onlymandatory
cpqRackSysObjID
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.3
cpqRackSystemObjectIdentification
OBJECT-TYPE
The hardware identification string. The string will reported by the rack firmware.
1.3.6.1.4.1.232.22.3.1DisplayString (SIZE(0..64))read-onlymandatory
cpqRackEventInfo
OBJECT-IDENTITY
1.3.6.1.4.1.232.22.4
cpqRackEventIndicationIdentifier
OBJECT-TYPE
The Event Indication Identifier.
1.3.6.1.4.1.232.22.4.1DisplayString (SIZE(0..25))read-onlymandatory
cpqRackEventIndicationTime
OBJECT-TYPE
The Event Indication Time.
1.3.6.1.4.1.232.22.4.2DisplayString (SIZE(0..33))read-onlyoptional
cpqRackEventDescription
OBJECT-TYPE
The Event Description.
1.3.6.1.4.1.232.22.4.3OCTET STRING (SIZE(0..1024))read-onlyoptional
cpqRackEventSummary
OBJECT-TYPE
Short description of the reason for the event.
1.3.6.1.4.1.232.22.4.4DisplayString (SIZE(0..255))read-onlyoptional
cpqRackEventCategory
OBJECT-TYPE
Category for the event. This category is intended to be used by the consumer to group events.
1.3.6.1.4.1.232.22.4.5INTEGER {unknown(1), other(2), processor(3), memory(4), systemHardware(5), supportHardware(6), primaryStorageDevice(7), secondaryStorageDevice(8), otherStorageDevice(9), networkDevice(10), otherDevice(11), ioAdapter(12), networkAdapter(13), otherAdapter(14), processorPower(15), memoryPower(16), systemPower(17), primaryStorageDevicePower(18), secondaryStoragePower(19), otherStoragePower(20), otherPower(21), processorCooling(22), memoryCooling(23), systemCooling(24), primaryStorageDeviceCooling(25), secondaryStorageDeviceCooling(26), otherStorageDeviceCooling(27), otherCooling(28), systemHWSecurity(29), primaryStorageDeviceSecurity(30), secondaryStorageDeviceSecurity(31), otherStorageDeviceSecurity(32), otherHWSecurity(33), systemInterconnect(34), supportInterconnect(35), clusterInterconnect(36), storageInterconnect(37), networkInterconnect(38), otherInterconnect(39), os(40), systemFirmware(41), deviceFirmware(42), supportFirmware(43), systemFirmwareSecurity(44), osSecurity(45), softwareApplication(46), softwareApplicationSecurity(47), nonStopIncident(48)}read-onlyoptional
cpqRackOtherEventCategory
OBJECT-TYPE
A string defining other values for EventCategory. It is empty unless EventCategory value is other(1).
1.3.6.1.4.1.232.22.4.6DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventSubCategory
OBJECT-TYPE
Sub-category for the event. This sub-category is intended to be used by the consumer in conjunction with the EventCategory to provide additional granularity to group events. It is expected that additional values will be added that can be used with other EventCategory values.
1.3.6.1.4.1.232.22.4.7INTEGERread-onlyoptional
cpqRackOtherEventSubCategory
OBJECT-TYPE
A string defining other values for EventSubCategory. It is empty unless EventSubCategory value is other(1)
1.3.6.1.4.1.232.22.4.8DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventThreshold
OBJECT-TYPE
Identifies the number of indications that need to occur as part of the internal provider throttling configured for this event.
1.3.6.1.4.1.232.22.4.9INTEGERread-onlyoptional
cpqRackEventTimeWin
OBJECT-TYPE
Identifies the time window during which the EventThreshold number of events need to occur as part of the internal provider throttling configured for this event. Time is in minutes. 0 means any amount of time.
1.3.6.1.4.1.232.22.4.10INTEGERread-onlyoptional
cpqRackEventActualThreshold
OBJECT-TYPE
Identifies the number of indications that have occurred to meet the internal provider throttling configured for this event.
1.3.6.1.4.1.232.22.4.11INTEGERread-onlyoptional
cpqRackEventActualTimeWin
OBJECT-TYPE
Identifies the time window during which the ActualEventThreshold number of events have occurred to meet the internal provider throttling configured for this event. Time is in minutes. 0 means any amount of time.
1.3.6.1.4.1.232.22.4.12INTEGERread-onlyoptional
cpqRackEventProviderVersion
OBJECT-TYPE
The version of the provider generating this indication.
1.3.6.1.4.1.232.22.4.13DisplayString (SIZE(0..31))read-onlyoptional
cpqRackEventAlertingElementFormat
OBJECT-TYPE
The format of the AlertingManagedElement property is interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unknown or not meaningfully interpretable by a CIM client application. 2 - other. The format is defined by the value of the OtherAlertingElementFormat property. 3 - cimObjectPath. The format is a CIMObjectPath, specifying an instance in the CIM Schema.
1.3.6.1.4.1.232.22.4.14INTEGER {unknown(1), other(2), cimObjectPath(3)}read-onlyoptional
cpqRackEventOtherAlertingElementFormat
OBJECT-TYPE
A string defining other values for AlertingElementFormat. It is empty unless cpqRackEventAlertingElementFormat value is other(1)
1.3.6.1.4.1.232.22.4.15OCTET STRING (SIZE(0..256))read-onlyoptional
cpqRackEventImpactedDomain
OBJECT-TYPE
ImpactedDomain is an enumerated value indicating the domain this event affects.
1.3.6.1.4.1.232.22.4.16INTEGER {unknown(1), cluster(2), complex(3), enclosure(4), system(5), partition(6)}read-onlyoptional
cpqRackEventComplexName
OBJECT-TYPE
The name of the complex.
1.3.6.1.4.1.232.22.4.17DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventPartitionId
OBJECT-TYPE
The Unique Identifier for the Partition. The format of the partitionId will be of the form nparId:vparId.
1.3.6.1.4.1.232.22.4.18DisplayString (SIZE(0..12))read-onlyoptional
cpqRackEventTriggeringLogIDTable
OBJECT-TYPE
A table of rack of Low Level LOG IDs.
1.3.6.1.4.1.232.22.4.19not-accessibleoptional
cpqRackEventTriggeringLogIDEntry
OBJECT-TYPE
The list of Low level LOG ID which were used to generate this event. The format of the value contained in this array is defined using the TriggeringLogIDFormat field.
1.3.6.1.4.1.232.22.4.19.1not-accessibleoptional
cpqRackEventTriggeringLogID
OBJECT-TYPE
A Low Lvevel LOG ID which were used to generate this event.
1.3.6.1.4.1.232.22.4.19.1.1OCTET STRING (SIZE(0..256))read-onlyoptional
cpqRackEventTriggeringLogIDFormat
OBJECT-TYPE
The format of the TriggeringLogID property which interpretable based upon the value of this property. Values are defined as: 1 - unknown. The format is unknown or not meaningfully interpretable by a CIM client application. 2 - cimObjectPath. The format is a CIMObjectPath, with format specifying an instance in the CIM Schema.
1.3.6.1.4.1.232.22.4.20INTEGER {unknown(1), cimObjectPath(2)}read-onlyoptional
cpqRackEventAlertType
OBJECT-TYPE
The event alert type.
1.3.6.1.4.1.232.22.4.21INTEGERread-onlyoptional
cpqRackEventOtherAlertType
OBJECT-TYPE
The event other alert type. It is empty unless cpqRackEventAlertType value is other.
1.3.6.1.4.1.232.22.4.22DisplayString (SIZE(0..33))read-onlyoptional
cpqRackEventProbableCause
OBJECT-TYPE
An enumerated value that describes the probable cause of the error.
1.3.6.1.4.1.232.22.4.23INTEGERread-onlyoptional
cpqRackEventProbableCauseDescription
OBJECT-TYPE
A free-form string describing the probable cause of the error.
1.3.6.1.4.1.232.22.4.24OCTET STRING (SIZE(0..1024))read-onlyoptional
cpqRackEventPerceivedSeverity
OBJECT-TYPE
An enumerated value that describes the severity of the Indication from the point of view of the notifier.
1.3.6.1.4.1.232.22.4.25INTEGERread-onlyoptional
cpqRackEventOtherSeverity
OBJECT-TYPE
Other perceived severity. It is empty unless cpqRackEventPerceivedSeverity value is other.
1.3.6.1.4.1.232.22.4.26DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventTrending
OBJECT-TYPE
The event trending.
1.3.6.1.4.1.232.22.4.27INTEGERread-onlyoptional
cpqRackEventRecommendedActions
OBJECT-TYPE
A free-form string describing recommended actions to take to resolve the error.
1.3.6.1.4.1.232.22.4.28OCTET STRING (SIZE(0..1024))read-onlyoptional
cpqRackEventID
OBJECT-TYPE
An instrumentation or provider specific value that describes the underlying real-world event represented by the indication related to the not-OK status.
1.3.6.1.4.1.232.22.4.29DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventTime
OBJECT-TYPE
The event time.
1.3.6.1.4.1.232.22.4.30DisplayString (SIZE(0..33))read-onlyoptional
cpqRackEventSystemCreationClassName
OBJECT-TYPE
The event system creation class name.
1.3.6.1.4.1.232.22.4.31DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventSystemName
OBJECT-TYPE
The event system name.
1.3.6.1.4.1.232.22.4.32DisplayString (SIZE(0..64))read-onlyoptional
cpqRackEventProviderName
OBJECT-TYPE
The name of the Provider that generated the indication related to the not-OK status.
1.3.6.1.4.1.232.22.4.33DisplayString (SIZE(0..64))read-onlyoptional

Notifications

NameOIDStatus
cpqRackNameChanged
NOTIFICATION-TYPE
Rack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack will be updated to reflect the new rack name. It may take several minutes for the rack name change to be propagated throughout the entire rack. User Action: None.
1.3.6.1.4.1.232.0.22001
cpqRackEnclosureNameChanged
NOTIFICATION-TYPE
The enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack will be updated to reflect the new enclosure name. It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure. User Action: None.
1.3.6.1.4.1.232.0.22002
cpqRackEnclosureRemoved
NOTIFICATION-TYPE
The enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None.
1.3.6.1.4.1.232.0.22003
cpqRackEnclosureInserted
NOTIFICATION-TYPE
The enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None.
1.3.6.1.4.1.232.0.22004
cpqRackEnclosureTempFailed
NOTIFICATION-TYPE
The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked.
1.3.6.1.4.1.232.0.22005
cpqRackEnclosureTempDegraded
NOTIFICATION-TYPE
The enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked.
1.3.6.1.4.1.232.0.22006
cpqRackEnclosureTempOk
NOTIFICATION-TYPE
The enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None.
1.3.6.1.4.1.232.0.22007
cpqRackEnclosureFanFailed
NOTIFICATION-TYPE
The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.
1.3.6.1.4.1.232.0.22008
cpqRackEnclosureFanDegraded
NOTIFICATION-TYPE
The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.
1.3.6.1.4.1.232.0.22009
cpqRackEnclosureFanOk
NOTIFICATION-TYPE
The enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.0.22010
cpqRackEnclosureFanRemoved
NOTIFICATION-TYPE
The enclosure fan has been removed. User Action: None.
1.3.6.1.4.1.232.0.22011
cpqRackEnclosureFanInserted
NOTIFICATION-TYPE
The enclosure fan has been inserted. User Action: None.
1.3.6.1.4.1.232.0.22012
cpqRackPowerSupplyFailed
NOTIFICATION-TYPE
The power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible.
1.3.6.1.4.1.232.0.22013
cpqRackPowerSupplyDegraded
NOTIFICATION-TYPE
The power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possible.
1.3.6.1.4.1.232.0.22014
cpqRackPowerSupplyOk
NOTIFICATION-TYPE
The power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.0.22015
cpqRackPowerSupplyRemoved
NOTIFICATION-TYPE
The power supply has been removed. User Action: None.
1.3.6.1.4.1.232.0.22016
cpqRackPowerSupplyInserted
NOTIFICATION-TYPE
The power supply has been inserted. User Action: None.
1.3.6.1.4.1.232.0.22017
cpqRackPowerSubsystemNotRedundant
NOTIFICATION-TYPE
The rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
1.3.6.1.4.1.232.0.22018
cpqRackPowerSubsystemLineVoltageProblem
NOTIFICATION-TYPE
The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible.
1.3.6.1.4.1.232.0.22019
cpqRackPowerSubsystemOverloadCondition
NOTIFICATION-TYPE
The rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
1.3.6.1.4.1.232.0.22020
cpqRackPowerShedAutoShutdown
NOTIFICATION-TYPE
Server shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies.
1.3.6.1.4.1.232.0.22021
cpqRackServerPowerOnFailedNotRedundant
NOTIFICATION-TYPE
Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.
1.3.6.1.4.1.232.0.22022
cpqRackServerPowerOnFailedNotEnoughPower
NOTIFICATION-TYPE
Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies.
1.3.6.1.4.1.232.0.22023
cpqRackServerPowerOnFailedEnclosureNotFound
NOTIFICATION-TYPE
Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies.
1.3.6.1.4.1.232.0.22024
cpqRackServerPowerOnFailedPowerChassisNotFound
NOTIFICATION-TYPE
Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check power enclosure connections or add power supplies.
1.3.6.1.4.1.232.0.22025
cpqRackServerPowerOnManualOverride
NOTIFICATION-TYPE
Server power on via manual override. The server blade was powered on by a manual override. User Action: None.
1.3.6.1.4.1.232.0.22026
cpqRackFuseOpen
NOTIFICATION-TYPE
Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse.
1.3.6.1.4.1.232.0.22027
cpqRackServerBladeRemoved
NOTIFICATION-TYPE
Server blade removed. The server blade has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22028
cpqRackServerBladeInserted
NOTIFICATION-TYPE
Server blade inserted. The server blade has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22029
cpqRackPowerChassisNotLoadBalanced
NOTIFICATION-TYPE
Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.
1.3.6.1.4.1.232.0.22030
cpqRackPowerChassisDcPowerProblem
NOTIFICATION-TYPE
Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
1.3.6.1.4.1.232.0.22031
cpqRackPowerChassisAcFacilityPowerExceeded
NOTIFICATION-TYPE
Power subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
1.3.6.1.4.1.232.0.22032
cpqRackPowerUnknownPowerConsumption
NOTIFICATION-TYPE
Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
1.3.6.1.4.1.232.0.22033
cpqRackPowerChassisLoadBalancingWireMissing
NOTIFICATION-TYPE
Power subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire.
1.3.6.1.4.1.232.0.22034
cpqRackPowerChassisTooManyPowerChassis
NOTIFICATION-TYPE
Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure.
1.3.6.1.4.1.232.0.22035
cpqRackPowerChassisConfigError
NOTIFICATION-TYPE
Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure.
1.3.6.1.4.1.232.0.22036
cpqRackEnclosureManagerDegraded
NOTIFICATION-TYPE
The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed, their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG. For all the others please refer to product documentation for possible corrective actions
1.3.6.1.4.1.232.0.22037
cpqRackEnclosureManagerOk
NOTIFICATION-TYPE
The Onboard Administrator or other management processor's status has been set to ok. This trap signifies that an Onboard Administrator or other management processor has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.0.22038
cpqRackEnclosureManagerRemoved
NOTIFICATION-TYPE
The Onboard Administrator has been removed. User Action: None.
1.3.6.1.4.1.232.0.22039
cpqRackEnclosureManagerInserted
NOTIFICATION-TYPE
The Onboard Administrator or other management processor has been inserted. User Action: None.
1.3.6.1.4.1.232.0.22040
cpqRackManagerPrimaryRole
NOTIFICATION-TYPE
The Onboard Administrator or other management processor has taken the role of primary. User Action: None.
1.3.6.1.4.1.232.0.22041
cpqRackServerBladeEKeyingFailed
NOTIFICATION-TYPE
The server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz card and the interconnect. User Action: Reconfigure server blade mezz cards.
1.3.6.1.4.1.232.0.22042
cpqRackServerBladeEKeyingOK
NOTIFICATION-TYPE
The server blade e-keying is ok. This trap signifies that a server blade e-keying has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.0.22043
cpqRackNetConnectorRemoved
NOTIFICATION-TYPE
Interconnect removed. The interconnect has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22044
cpqRackNetConnectorInserted
NOTIFICATION-TYPE
Interconnect inserted. The interconnect has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22045
cpqRackNetConnectorFailed
NOTIFICATION-TYPE
The interconnect status has been set to failed. This trap signifies that a interconnect has failed. User Action: Replace the interconnect as soon as possible.
1.3.6.1.4.1.232.0.22046
cpqRackNetConnectorDegraded
NOTIFICATION-TYPE
The interconnect status has been set to degraded. This trap signifies that a interconnect has degraded. User Action: Refer to the OA and the status diagnostics reported for the interconnect.
1.3.6.1.4.1.232.0.22047
cpqRackNetConnectorOk
NOTIFICATION-TYPE
The interconnect status has been set to ok. This trap signifies that a interconnect has returned to normal operation. User Action: None.
1.3.6.1.4.1.232.0.22048
cpqRackServerBladeToLowPower
NOTIFICATION-TYPE
The server blade requested to low power. User Action: None.
1.3.6.1.4.1.232.0.22049
cpqRackServerBladeRemoved2
NOTIFICATION-TYPE
Server blade removed. The server blade has been removed from the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22050
cpqRackServerBladeInserted2
NOTIFICATION-TYPE
Server blade inserted. The server blade has been inserted into the enclosure. User Action: None.
1.3.6.1.4.1.232.0.22051
cpqRackServerBladeStatusRepaired
NOTIFICATION-TYPE
Server blade repaired. The server blade status has changed to OK. User Action: None.
1.3.6.1.4.1.232.0.22052
cpqRackServerBladeStatusDegraded
NOTIFICATION-TYPE
Server blade health status Degraded. The server blade health status has changed to Degraded. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.0.22053
cpqRackServerBladeStatusCritical
NOTIFICATION-TYPE
Server blade health status Critical. The server blade health status has changed to Critical. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.0.22054
cpqRackServerBladeGrpCapTimeout
NOTIFICATION-TYPE
The server blade is not responding to the group capper. The server blade is not responding to capping requests from the enclosure group capper User Action: Reset the iLO management processor.
1.3.6.1.4.1.232.0.22055
cpqRackServerBladeUnexpectedShutdown
NOTIFICATION-TYPE
Server blade shutdown unexpectadly. An unexpected shutdown event has occurred for this server blade. User Action: Check blade server and enclosure SYSLOG.
1.3.6.1.4.1.232.0.22056
cpqRackServerBladeMangementControllerFirmwareUpdating
NOTIFICATION-TYPE
Server blade's management controller firmware updating. This server blade's management controller has started updating it's firmware. User Action: None.
1.3.6.1.4.1.232.0.22057
cpqRackServerBladeMangementControllerFirmwareUpdateComplete
NOTIFICATION-TYPE
Server blade's management controller firmware update has completed. This server blade's management controller has finished updating it's firmware. User Action: None.
1.3.6.1.4.1.232.0.22058
cpqRackServerBladeSystemBIOSFirmwareUpdating
NOTIFICATION-TYPE
Server blade's system BIOS firmware updating. This server blade's system BIOS has started updating. User Action: None.
1.3.6.1.4.1.232.0.22059
cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted
NOTIFICATION-TYPE
Server blade's system BIOS firmware update complete. This server blade's system BIOS has completed updating. User Action: None.
1.3.6.1.4.1.232.0.22060
cpqRackServerBladeFrontIOBlankingActive
NOTIFICATION-TYPE
Server blade has disabled front IO ports. Front IO blanking status has changed to active for this server blade. User Action: None.
1.3.6.1.4.1.232.0.22061
cpqRackServerBladeRemoteFrontIOBlankingInactive
NOTIFICATION-TYPE
Server blade has front IO blanking mode now inactive. Front IO blanking status has changed to inactive for this server blade. User Action: None.
1.3.6.1.4.1.232.0.22062
cpqRackServerBladeDiagnosticAdaptorInserted
NOTIFICATION-TYPE
Server blade diagnostic adaptor inserted. Blade diagnostic adaptor status has changed to inserted for this server blade. User Action: None.
1.3.6.1.4.1.232.0.22063
cpqRackServerBladeDiagnosticAdaptorRemoved
NOTIFICATION-TYPE
Server blade diagnostic adaptor removed. Blade diagnostic adaptor status has changed to removed for this server blade. User Action: None.
1.3.6.1.4.1.232.0.22064
cpqRackServerBladeEnteredPXEBootMode
NOTIFICATION-TYPE
Server blade has entered PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode started. User Action: None.
1.3.6.1.4.1.232.0.22065
cpqRackServerBladeExitedPXEBootMode
NOTIFICATION-TYPE
Server blade has exited PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode exited. User Action: None.
1.3.6.1.4.1.232.0.22066
cpqRackServerBladeWarmReset
NOTIFICATION-TYPE
Server blade has been warm reset. Server blade has experienced a warm reset. User Action: None.
1.3.6.1.4.1.232.0.22067
cpqRackServerBladePOSTCompleted
NOTIFICATION-TYPE
Server blade system BIOS POST complete. Server blade has completed system BIOS Power-On-Self-Test (POST). User Action: None.
1.3.6.1.4.1.232.0.22068
cpqRackServerBladePoweredOn
NOTIFICATION-TYPE
Server blade has powered on. User Action: None.
1.3.6.1.4.1.232.0.22069
cpqRackServerBladePoweredOff
NOTIFICATION-TYPE
Server blade has powered off. User Action: None.
1.3.6.1.4.1.232.0.22070
cpqRackInformationalEAETrap
NOTIFICATION-TYPE
EAE Informational trap
1.3.6.1.4.1.232.0.22071
cpqRackMinorEAETrap
NOTIFICATION-TYPE
EAE Minor trap
1.3.6.1.4.1.232.0.22072
cpqRackMajorEAETrap
NOTIFICATION-TYPE
EAE Major trap
1.3.6.1.4.1.232.0.22073
cpqRackCriticalEAETrap
NOTIFICATION-TYPE
EAE Critical trap
1.3.6.1.4.1.232.0.22074
cpqRackPowerMinorEAETrap
NOTIFICATION-TYPE
FlexFabric Cmdr Power Subsystem Minor trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.0.22075
cpqRackPowerMajorEAETrap
NOTIFICATION-TYPE
FlexFabric Cmdr Power Subsystem Major trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.0.22076
cpqRackPowerCriticalEAETrap
NOTIFICATION-TYPE
FlexFabric Cmdr Power Subsystem Critical trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
1.3.6.1.4.1.232.0.22077
cpqRackServerBladePartitionChange
NOTIFICATION-TYPE
Server Blade Partition Changed trap. The server blade is part of a conjoined blade and its partition has changed. User Action: None.
1.3.6.1.4.1.232.0.22078
cpqRackInformationalWSMANTrap
NOTIFICATION-TYPE
WSMAN Informational trap
1.3.6.1.4.1.232.0.22079
cpqRackMinorWSMANTrap
NOTIFICATION-TYPE
WSMAN Minor trap
1.3.6.1.4.1.232.0.22080
cpqRackMajorWSMANTrap
NOTIFICATION-TYPE
WSMAN Major trap
1.3.6.1.4.1.232.0.22081
cpqRackCriticalWSMANTrap
NOTIFICATION-TYPE
WSMAN Critical trap
1.3.6.1.4.1.232.0.22082
cpqRackEnclosureManagerLinkDown
NOTIFICATION-TYPE
The Onboard Administrator Network Link is Down. The Onboard Administrator firmware has detected the loss of network link. User Action: Check network connection and configurations for the Onboard Administrator.
1.3.6.1.4.1.232.0.22083
cpqRackEnclosureManagerLinkUp
NOTIFICATION-TYPE
The Onboard Administrator Network Link is Up. The Onboard Administrator firmware has detected the presence of network link. User Action: None.
1.3.6.1.4.1.232.0.22084
cpqRackErsCommFailure
NOTIFICATION-TYPE
The Onboard Administrator to Insight Remote Support or Insight Online communication failed. User Action: Please check the connectivity to Insight Remote Support or Insight Online.
1.3.6.1.4.1.232.0.22085
cpqRackPowerSubsystemOverloadConditionRepaired
NOTIFICATION-TYPE
The rack power subsystem overload condition repaired.
1.3.6.1.4.1.232.0.22086