CME-MIB
- Registered at
- 1.3.6.1.4.1.2.3.51.2.2.1.91.3.6.1.4.1.2.3.51.2.2.301.3.6.1.4.1.2.3.51.2.4.3.51.3.6.1.4.1.2.3.51.2.22.121.3.6.1.4.1.2.3.51.2.22.311.3.6.1.4.1.2.3.51.2.22.321.3.6.1.4.1.2.3.51.2.22.381.3.6.1.4.1.2.3.51.2.22.391.3.6.1.4.1.2.3.51.2.22.421.3.6.1.4.1.2.3.51.2.23.101.3.6.1.4.1.2.3.51.2.23.151.3.6.1.4.1.2.3.51.2.23.21
- Namespace
- ibm
- Source file
CME-MIB- Digest
sha256:b1eddaa9cb18280d777c78131de6c70fa27895401f43b896ace297457966ac2f
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CME-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| EntryStatus type | ||||
| InetAddressIPv6 TEXTUAL-CONVENTION Represents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6 | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ibm OBJECT-IDENTITY | 1.3.6.1.4.1.2 | |||
| ibmAgents OBJECT-IDENTITY | 1.3.6.1.4.1.2.3 | |||
| netfinitySupportProcessorAgent OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51 | |||
| bladeCenterSnmpMIB OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2 | |||
| monitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2 | |||
| temperature OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1 | |||
| internalTemp OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1.1 | |||
| cmmTemp OBJECT-TYPE This field is deprecated. The return value of this field is the same as rearLEDCardTemp. Chassis management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.1.2 | OCTET STRING | read-only | deprecated |
| ambientTemp OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1.5 | |||
| rearLEDCardTempAvg OBJECT-TYPE The average rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.5.1 | OCTET STRING | read-only | mandatory |
| rearLEDCardTempMin OBJECT-TYPE The minimum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.5.2 | OCTET STRING | read-only | mandatory |
| rearLEDCardTempMax OBJECT-TYPE The maximum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.5.3 | OCTET STRING | read-only | mandatory |
| monitorTemp OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1.9 | |||
| hotAirRecircMonitoring OBJECT-TYPE If this is enabled, the management module will monitor for Hot Air Recirculation by detecting non-uniform air temperature(s) that may be entering the front of the chassis. This could be due to either localized hot or cold air reaching at least one of the node's or chassis temperature sensors and it exceeding the acceptable range. When enabled, this monitor will generate an event and be transmitted to any configured remote alert recipient. | 1.3.6.1.4.1.2.3.51.2.2.1.9.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| hotAirRecircTempDeltaThresh OBJECT-TYPE This object is used to read or change the temperature delta threshold for Hot Air Recirculation detection. Values are enforced to be in the inclusive range between 5.00C and 9.00C and are specified as hundreths of a degree. For example, a value of 659 would equate to a threshold of 6.59 degrees C. | 1.3.6.1.4.1.2.3.51.2.2.1.9.5 | INTEGER | read-write | mandatory |
| hotAirRecircStatusTable OBJECT-TYPE Table of hot air recirculation status information. | 1.3.6.1.4.1.2.3.51.2.2.1.9.7 | not-accessible | mandatory | |
| hotAirRecircStatusEntry OBJECT-TYPE Hot air recirculation status entry | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1 | not-accessible | mandatory | |
| hotAirRecircStatusTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.2 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| hotAirRecircStatusIndex OBJECT-TYPE Each component may have one or more sensor associated with it, this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.3 | INTEGER | read-only | mandatory |
| hotAirRecircStatusName OBJECT-TYPE The name of the component as a null terminated string | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.4 | OCTET STRING | read-only | mandatory |
| hotAirRecircStatusSensorLabel OBJECT-TYPE The text label of the sensor as a null terminated string | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.5 | OCTET STRING | read-only | mandatory |
| hotAirRecircStatusSensorReading OBJECT-TYPE Ambient temperature reading for this component in degrees centigrade(C). The string is formatted as 'dd.dd Centigrade'. | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.6 | OCTET STRING | read-only | mandatory |
| hotAirRecircStatusExceeded OBJECT-TYPE Indicates whether this component has exceeded the threshold of the acceptable temperature being monitored for hot air recirculation. | 1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.7 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| chassisFans OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.3 | |||
| chassisFansTable OBJECT-TYPE Table of chassis Fan information. | 1.3.6.1.4.1.2.3.51.2.2.3.50 | not-accessible | mandatory | |
| chassisFansEntry OBJECT-TYPE Chassis Fan information entry | 1.3.6.1.4.1.2.3.51.2.2.3.50.1 | not-accessible | mandatory | |
| chassisFanIndex OBJECT-TYPE Chassis Fans table index. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.1 | INTEGER (0..128) | read-only | mandatory |
| chassisFanId OBJECT-TYPE The numeric chassis fan ID. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.2 | INTEGER {chassisfan1(1), chassisfan2(2), chassisfan3(3), chassisfan4(4), chassisfan5(5), chassisfan6(6), chassisfan7(7), chassisfan8(8), chassisfan9(9), chassisfan10(10)} | read-only | mandatory |
| chassisFanSpeed OBJECT-TYPE Chassis fan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.3 | OCTET STRING | read-only | mandatory |
| chassisFanState OBJECT-TYPE The health state for the chassis fan. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.4 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| chassisFanSpeedRPM OBJECT-TYPE Chassis fan speed expressed in RPM. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.5 | OCTET STRING | read-only | mandatory |
| chassisFanControllerState OBJECT-TYPE The controller health state for the chassis fan. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.6 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| chassisFanCoolingZone OBJECT-TYPE The cooling zone for the chassis fan. | 1.3.6.1.4.1.2.3.51.2.2.3.50.1.7 | INTEGER {unknown(0), coolingZone1(1), coolingZone2(2), coolingZone3(3), coolingZone4(4)} | read-only | mandatory |
| chassisCoolingZoneTable OBJECT-TYPE Table of chassis cooling zone information. | 1.3.6.1.4.1.2.3.51.2.2.3.51 | not-accessible | mandatory | |
| chassisCoolingZoneEntry OBJECT-TYPE Chassis cooling zone information entry | 1.3.6.1.4.1.2.3.51.2.2.3.51.1 | not-accessible | mandatory | |
| chassisCoolingIndex OBJECT-TYPE Chassis Cooling Zones table index. | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.1 | INTEGER (0..128) | read-only | mandatory |
| chassisCoolingZone OBJECT-TYPE The cooling zone for the chassis component. | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.2 | INTEGER {coolingZone1(1), coolingZone2(2), coolingZone3(3), coolingZone4(4)} | read-only | mandatory |
| chassisCoolingZoneStatus OBJECT-TYPE The health state of the chassis cooling zone. Note: This is the health of the cooling zone, not the health status of the component in chassisCoolingZoneComponent. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.3 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| chassisCoolingZoneComponent OBJECT-TYPE A component within a cooling zone. | 1.3.6.1.4.1.2.3.51.2.2.3.51.1.4 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14), switchModule1(41), switchModule2(42), switchModule3(43), switchModule4(44), mgmtModule1(61), mgmtModule2(62), fan1(81), fan2(82), fan3(83), fan4(84), fan5(85), fan6(86), fan7(87), fan8(88), fan9(89), fan10(90)} | read-only | mandatory |
| powerModuleHealth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.4 | |||
| powerModuleHealthTable OBJECT-TYPE Table of power module health information. Contains the power health information for each power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1 | not-accessible | mandatory | |
| powerModuleHealthEntry OBJECT-TYPE Power Module health entry | 1.3.6.1.4.1.2.3.51.2.2.4.1.1 | not-accessible | mandatory | |
| powerModuleIndex OBJECT-TYPE Power module index. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.1 | INTEGER | read-only | mandatory |
| powerModuleExists OBJECT-TYPE Indicates whether the power module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| powerModuleState OBJECT-TYPE The health state for the power module. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.3 | INTEGER {unknown(0), good(1), warning(2), notAvailable(3), critical(4)} | read-only | mandatory |
| powerModuleDetails OBJECT-TYPE The details for this power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.4 | OCTET STRING | read-only | mandatory |
| powerModuleDescription OBJECT-TYPE The description for this power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.9 | OCTET STRING | read-only | mandatory |
| spStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5 | |||
| mmBistAndChassisStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5.2 | |||
| bistRtc OBJECT-TYPE MM BIST Real Time Clock test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.5 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistLocalI2CBus OBJECT-TYPE MM BIST Local I2C bus test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.7 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPrimaryMainAppFlashImage OBJECT-TYPE MM BIST Primary Main Application Firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.8 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistSecondaryMainAppFlashImage OBJECT-TYPE MM BIST Secondary Main Application test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.9 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistBootRomFlashImage OBJECT-TYPE MM BIST Boot Firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.10 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistEthernetPort1 OBJECT-TYPE MM BIST external eth0 ethernet port test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.11 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistExternalI2CDevices OBJECT-TYPE MM BIST external I2C devices test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.14 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistInternalEthernetSwitch OBJECT-TYPE MM BIST internal external switch test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.19 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPrimaryKernel OBJECT-TYPE MM BIST primary kernel test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.25 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistSecondaryKernel OBJECT-TYPE MM BIST secondary kernel test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.26 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPhysicalNetworkLink OBJECT-TYPE MM BIST Physical Network Link test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.29 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistLogicalNetworkLink OBJECT-TYPE MM BIST Logical Network Link test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.30 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistBladesInstalled OBJECT-TYPE The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.33 | OCTET STRING | read-only | mandatory |
| bistBladesCommunicating OBJECT-TYPE The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.49 | OCTET STRING | read-only | mandatory |
| bistChassisFansInstalled OBJECT-TYPE The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.65 | OCTET STRING | read-only | mandatory |
| bistChassisFansFunctional OBJECT-TYPE The chassis fans installed on the chassis that are functional. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.73 | OCTET STRING | read-only | mandatory |
| bistRearLEDCardInstalled OBJECT-TYPE Indicates whether a rear LED card is installed | 1.3.6.1.4.1.2.3.51.2.2.5.2.74 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistRearLEDCardCommunicating OBJECT-TYPE Indicates whether a rear LED card is communicating | 1.3.6.1.4.1.2.3.51.2.2.5.2.75 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistOtherMMInstalled OBJECT-TYPE Indicates whether a redundant MM is installed. | 1.3.6.1.4.1.2.3.51.2.2.5.2.76 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistOtherMMCommunicating OBJECT-TYPE Indicates whether a redundant MM is communicating. | 1.3.6.1.4.1.2.3.51.2.2.5.2.77 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistPowerModulesInstalled OBJECT-TYPE The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.81 | OCTET STRING | read-only | mandatory |
| bistPowerModulesFunctional OBJECT-TYPE The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.89 | OCTET STRING | read-only | mandatory |
| bistSwitchModulesInstalled OBJECT-TYPE The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.97 | OCTET STRING | read-only | mandatory |
| bistSwitchModulesCommunicating OBJECT-TYPE The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.113 | OCTET STRING | read-only | mandatory |
| bistChassisFansMUXAInstalled OBJECT-TYPE Indicates whether chassis fan MUX A is installed | 1.3.6.1.4.1.2.3.51.2.2.5.2.120 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistChassisFansMUXAFunctional OBJECT-TYPE Indicates whether chassis fan MUX A is functional | 1.3.6.1.4.1.2.3.51.2.2.5.2.121 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistChassisFansMUXBInstalled OBJECT-TYPE Indicates whether chassis fan MUX B is installed | 1.3.6.1.4.1.2.3.51.2.2.5.2.122 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistChassisFansMUXBFunctional OBJECT-TYPE Indicates whether chassis fan MUX B is functional | 1.3.6.1.4.1.2.3.51.2.2.5.2.123 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistLastUpdate OBJECT-TYPE It is the time when the primary MM updated the last BIST results. | 1.3.6.1.4.1.2.3.51.2.2.5.2.200 | OCTET STRING | read-only | mandatory |
| rmmBistAndChassisStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5.3 | |||
| rbistRtc OBJECT-TYPE Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.5 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistLocalI2CBus OBJECT-TYPE Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.7 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistEthernetPort1 OBJECT-TYPE Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.11 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistExternalI2CDevices OBJECT-TYPE Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.14 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistInternalEthernetSwitch OBJECT-TYPE Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.19 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistPhysicalNetworkLink OBJECT-TYPE Standby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.29 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistLogicalNetworkLink OBJECT-TYPE Standby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.30 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistBladesInstalled OBJECT-TYPE The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.33 | OCTET STRING | read-only | mandatory |
| rbistBladesCommunicating OBJECT-TYPE The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.49 | OCTET STRING | read-only | mandatory |
| rbistChassisFansInstalled OBJECT-TYPE The chassis fans that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of chassis fans supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.65 | OCTET STRING | read-only | mandatory |
| rbistChassisFansFunctional OBJECT-TYPE The chassis fans installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If it is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if one is installed and functional only in bay 1, and 2 are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.73 | OCTET STRING | read-only | mandatory |
| rbistRearLEDCardInstalled OBJECT-TYPE Indicates whether a rear LED card is installed | 1.3.6.1.4.1.2.3.51.2.2.5.3.74 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistRearLEDCardCommunicating OBJECT-TYPE Indicates whether a rear LED card is communicating | 1.3.6.1.4.1.2.3.51.2.2.5.3.75 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistOtherMMInstalled OBJECT-TYPE Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.76 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistOtherMMCommunicating OBJECT-TYPE Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.77 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistPowerModulesInstalled OBJECT-TYPE The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.81 | OCTET STRING | read-only | mandatory |
| rbistPowerModulesFunctional OBJECT-TYPE The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.89 | OCTET STRING | read-only | mandatory |
| rbistSwitchModulesInstalled OBJECT-TYPE The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.97 | OCTET STRING | read-only | mandatory |
| rbistSwitchModulesCommunicating OBJECT-TYPE The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.113 | OCTET STRING | read-only | mandatory |
| rbistChassisFansMUXAInstalled OBJECT-TYPE Indicates whether chassis fan MUX A is installed | 1.3.6.1.4.1.2.3.51.2.2.5.3.120 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistChassisFansMUXAFunctional OBJECT-TYPE Indicates whether chassis fan MUX A is functional | 1.3.6.1.4.1.2.3.51.2.2.5.3.121 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistChassisFansMUXBInstalled OBJECT-TYPE Indicates whether chassis fan MUX B is installed | 1.3.6.1.4.1.2.3.51.2.2.5.3.122 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistChassisFansMUXBFunctional OBJECT-TYPE Indicates whether chassis fan MUX B is functional | 1.3.6.1.4.1.2.3.51.2.2.5.3.123 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistUpdateTime OBJECT-TYPE It is the time when the standby MM updated the last BIST results. | 1.3.6.1.4.1.2.3.51.2.2.5.3.200 | OCTET STRING | read-only | mandatory |
| rbistLastUpdatePrimary OBJECT-TYPE It is the time when the standby MM updated the last BIST results when it was still primary. | 1.3.6.1.4.1.2.3.51.2.2.5.3.201 | OCTET STRING | read-only | mandatory |
| fanPack OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.6 | |||
| fanPackTable OBJECT-TYPE Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.6.1 | not-accessible | mandatory | |
| fanPackEntry OBJECT-TYPE Fan Pack entry | 1.3.6.1.4.1.2.3.51.2.2.6.1.1 | not-accessible | mandatory | |
| fanPackIndex OBJECT-TYPE Fan Pack sequence index. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.1 | INTEGER | read-only | mandatory |
| fanPackExists OBJECT-TYPE Indicates whether the fan pack specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| fanPackState OBJECT-TYPE The health state for the fan pack. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.3 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| fanPackFanCount OBJECT-TYPE The number of fans in the fan pack. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.4 | INTEGER {unknown(255)} | read-only | mandatory |
| fanPackAverageSpeed OBJECT-TYPE The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.5 | OCTET STRING | read-only | mandatory |
| fanPackAverageSpeedRPM OBJECT-TYPE The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.6 | OCTET STRING | read-only | mandatory |
| fanPackControllerState OBJECT-TYPE The health state for the controller for the fan pack. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.7 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| systemHealth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.7 | |||
| systemHealthStat OBJECT-TYPE Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally. | 1.3.6.1.4.1.2.3.51.2.2.7.1 | INTEGER {critical(0), nonCritical(2), systemLevel(4), normal(255)} | read-only | mandatory |
| systemHealthSummaryTable OBJECT-TYPE Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. | 1.3.6.1.4.1.2.3.51.2.2.7.2 | not-accessible | mandatory | |
| systemHealthSummaryEntry OBJECT-TYPE System Health Summary entry | 1.3.6.1.4.1.2.3.51.2.2.7.2.1 | not-accessible | mandatory | |
| systemHealthSummaryIndex OBJECT-TYPE System health summary index. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.1 | INTEGER | read-only | mandatory |
| systemHealthSummarySeverity OBJECT-TYPE System health summary severity. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.2 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryDescription OBJECT-TYPE System health summary description. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.3 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryDateTime OBJECT-TYPE System health summary date time. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.4 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryAuxData OBJECT-TYPE System health summary auxilliary event data. If auxilliary event data is available, it is device-specific event data provided to the CMM by the device. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.11 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryEventID OBJECT-TYPE System health summary event ID. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.12 | OCTET STRING | read-only | mandatory |
| leds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8 | |||
| frontPanelLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.1 | |||
| faultLED OBJECT-TYPE Indicates whether the front panel system error LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.1.1 | INTEGER {off(0), on(1)} | read-only | mandatory |
| checkLogLED OBJECT-TYPE Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. | 1.3.6.1.4.1.2.3.51.2.2.8.1.2 | INTEGER {off(0), on(1)} | read-write | mandatory |
| identifyLED OBJECT-TYPE Indicates whether the front panel identity LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.1.4 | INTEGER {off(0), on(1), blinking(2), notAvailable(3)} | read-write | mandatory |
| bladeLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.2 | |||
| bladeLEDsTable OBJECT-TYPE Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1 | not-accessible | mandatory | |
| bladeLEDsEntry OBJECT-TYPE Blade system status entry | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1 | not-accessible | mandatory | |
| ledBladeIndex OBJECT-TYPE Blade LED table index. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1 | INTEGER | read-only | mandatory |
| ledBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| ledBladeExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| ledBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| ledBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6 | OCTET STRING | read-only | mandatory |
| ledBladeFault OBJECT-TYPE Indicates whether the blade fault LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7 | INTEGER {off(0), on(1)} | read-only | mandatory |
| ledBladeCheckLog OBJECT-TYPE Indicates whether the blade check log information LED is on or off. For Write access, the LED can be turned off only. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8 | INTEGER {off(0), on(1)} | read-write | mandatory |
| ledBladeIdentify OBJECT-TYPE Indicates whether the blade identify LED is on, off, or blinking. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11 | INTEGER {off(0), on(1), blinking(2)} | read-write | mandatory |
| bladeLEDsDetailsTable OBJECT-TYPE Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2 | not-accessible | mandatory | |
| bladeLEDsDetailsEntry OBJECT-TYPE Blade LEDs Details entry | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1 | not-accessible | mandatory | |
| ledIndex OBJECT-TYPE The LED index number. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1 | INTEGER | read-only | mandatory |
| ledBladeBayNumber OBJECT-TYPE The bay number of the main server blade that the LED is grouped into. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2 | OCTET STRING | read-only | mandatory |
| ledBladeComponentType OBJECT-TYPE Type of the component/subcomponent grouping for this LED. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3 | OCTET STRING | read-only | mandatory |
| ledBladeLabel OBJECT-TYPE Text label for a LED. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4 | OCTET STRING | read-only | mandatory |
| ledBladeState OBJECT-TYPE Text description which denotes color or on/off/blink state for a LED. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| ledBladeLocation OBJECT-TYPE Location of this LED. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6 | OCTET STRING | read-only | mandatory |
| smLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.4 | |||
| smLEDsTable OBJECT-TYPE Table of switch module LEDs information. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2 | not-accessible | mandatory | |
| smLEDsEntry OBJECT-TYPE Switch module LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1 | not-accessible | mandatory | |
| ledSMIndex OBJECT-TYPE Switch module LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.1 | INTEGER | read-only | mandatory |
| ledSMSlot OBJECT-TYPE The bay number of the switch. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.2 | INTEGER (0..128) | read-only | mandatory |
| ledSMLabel OBJECT-TYPE The name associated with the LED. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.3 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| ledSMState OBJECT-TYPE NOTE: This table entry is read-write ONLY when Label = 'Enclosure Identity'. All other Label values have read-only access. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.4 | INTEGER {off(0), on(1), blinking(2)} | read-write | mandatory |
| ledSMLocation OBJECT-TYPE The physical location where the LED can be found on the Switch. | 1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.5 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| chassisFanLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.5 | |||
| chassisFanLEDsTable OBJECT-TYPE Table of chassis fan LEDs information. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1 | not-accessible | mandatory | |
| chassisFanLEDsEntry OBJECT-TYPE Chassis fan LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1 | not-accessible | mandatory | |
| ledChassisFanIndex OBJECT-TYPE Chassis fan LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledChassisFanId OBJECT-TYPE The numeric chassis fan ID. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2 | INTEGER {chassisfan1(1), chassisfan2(2), chassisfan3(3), chassisfan4(4), chassisfan5(5), chassisfan6(6), chassisfan7(7), chassisfan8(8), chassisfan9(9), chassisfan10(10)} | read-only | mandatory |
| ledChassisFanExists OBJECT-TYPE Indicates whether the chassis fan specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledChassisFanError OBJECT-TYPE Indicates whether the chassis fan error LED is on, off, or not available. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4 | INTEGER {off(0), on(1), notAvailable(2)} | read-only | mandatory |
| fanPackLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.6 | |||
| fanPackLEDsTable OBJECT-TYPE Table of fan pack LEDs information. This table is deprecated because the LEDs for the power modules' fans are no longer on the fan packs, the LEDs are on the power modules. See the MIB tables, componentLEDsTable and componentLEDsDetailsTable, for the power modules' LEDs. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1 | not-accessible | deprecated | |
| fanPackLEDsEntry OBJECT-TYPE Fan Pack LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1 | not-accessible | deprecated | |
| ledFanPackIndex OBJECT-TYPE Fan Pack LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1 | INTEGER (0..128) | read-only | deprecated |
| ledFanPackId OBJECT-TYPE The numeric fan pack ID. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2 | INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4), fanPack5(5), fanPack6(6)} | read-only | deprecated |
| ledFanPackExists OBJECT-TYPE Indicates whether the fan pack specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| ledFanPackError OBJECT-TYPE Indicates whether the fan pack error LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4 | INTEGER {off(0), on(1), notAvailable(2)} | read-only | deprecated |
| fuelGauge OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10 | |||
| fuelGaugeInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.1 | |||
| fuelGaugeTable OBJECT-TYPE Table of Fuel Gauge information. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1 | not-accessible | mandatory | |
| fuelGaugeEntry OBJECT-TYPE Fuel Gauge entry | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1 | not-accessible | mandatory | |
| fuelGaugeIndex OBJECT-TYPE Fuel Gauge Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 | INTEGER | read-only | mandatory |
| fuelGaugePowerDomainNumber OBJECT-TYPE Fuel Gauge Table Power Domain Number. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 | INTEGER {powerDomain1(1)} | read-only | mandatory |
| fuelGaugeStatus OBJECT-TYPE Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 | OCTET STRING | read-only | mandatory |
| fuelGaugePowerModules OBJECT-TYPE Fuel Gauge Table Power Module capacity in Watts in the power domain. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4 | OCTET STRING | read-only | mandatory |
| fuelGaugePowerManagementPolicySetting OBJECT-TYPE Power Management Policy Setting for each power domain. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 | INTEGER {power-module-redundancy(0), power-module-redundancy-throttle(1), basic(2), power-source-redundancy(3), power-source-redundancy-throttle(4), notApplicable(255)} | read-only | mandatory |
| fuelGaugeTotalPower OBJECT-TYPE This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 | OCTET STRING | read-only | mandatory |
| fuelGaugeAllocatedPower OBJECT-TYPE This field displays the power that has been reserved in each power domain. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8 | OCTET STRING | read-only | mandatory |
| fuelGaugeRemainingPower OBJECT-TYPE This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 | OCTET STRING | read-only | mandatory |
| fuelGaugePowerInUsed OBJECT-TYPE This field displays the total power being used in each power domain. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 | OCTET STRING | read-only | mandatory |
| powerDomain1 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.2 | |||
| powerDomain1Table OBJECT-TYPE Table of Power Domain 1. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1 | not-accessible | mandatory | |
| powerDomain1Entry OBJECT-TYPE Fuel Gauge entry | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1 | not-accessible | mandatory | |
| pd1Index OBJECT-TYPE Power Domain 1 Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 | INTEGER | read-only | mandatory |
| pd1BayNumber OBJECT-TYPE Power Domain 1 Table Bay Number. The following Bay Number IDs are used: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), fanPackBay5(7), fanPackBay6(8), chassisfanBay1(9), chassisfanBay2(10), chassisfanBay3(11), chassisfanBay4(12), chassisfanBay5(13), chassisfanBay6(14), chassisfanBay7(15), chassisfanBay8(16), chassisfanBay9(17), chassisfanBay10(18), managementModuleBay1(19), managementModuleBay2(20), ioModuleBay1(21), ioModuleBay2(22), ioModuleBay3(23), ioModuleBay4(24), serverBladeBay1(25), serverBladeBay2(26), serverBladeBay3(27), serverBladeBay4(28), serverBladeBay5(29), serverBladeBay6(30), serverBladeBay7(31), serverBladeBay8(32), serverBladeBay9(33), serverBladeBay10(34), serverBladeBay11(35), serverBladeBay12(36), serverBladeBay13(37), serverBladeBay14(38), notApplicable(39) | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 | OCTET STRING | read-only | mandatory |
| pd1BladePrimarySlot OBJECT-TYPE Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd1ModuleStatus OBJECT-TYPE Power Domain 1 Table Module Throttle Status. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 | INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)} | read-only | mandatory |
| pd1ModuleName OBJECT-TYPE Power Domain 1 Table Module Name. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 | OCTET STRING | read-only | mandatory |
| pd1ModuleState OBJECT-TYPE Power Domain 1 Table Module State. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 | INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)} | read-only | mandatory |
| pd1ModuleAllocatedPowerCurrent OBJECT-TYPE Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 | OCTET STRING | read-only | mandatory |
| pd1ModuleAllocatedPowerMax OBJECT-TYPE Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 | OCTET STRING | read-only | mandatory |
| pd1ModuleAllocatedPowerMin OBJECT-TYPE Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 | OCTET STRING | read-only | mandatory |
| pd1ModuleCPUDutyCycles OBJECT-TYPE Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 | OCTET STRING | read-only | mandatory |
| pd1ModuleThrottle OBJECT-TYPE Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd1ModulePowerCapabilities OBJECT-TYPE Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 | INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)} | read-only | mandatory |
| pd1ModuleMeasuredOrStatic OBJECT-TYPE Power Domain 1 Table Module Measured Or Static. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 | INTEGER {static(0), measured(1), notApplicable(255)} | read-only | mandatory |
| pd1TopologyPath OBJECT-TYPE The topology path for the component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.14 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| powerDomain1PowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.2.3 | |||
| pd1PowerTrendingPeriod OBJECT-TYPE Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| pd1PowerTrendingSampleTable OBJECT-TYPE Table of Power Domain 1 Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10 | not-accessible | mandatory | |
| pd1PowerTrendingSampleEntry OBJECT-TYPE Power Domain 1 Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1 | not-accessible | mandatory | |
| pd1PowerTrendingSampleIndex OBJECT-TYPE Power Domain 1 Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1 | INTEGER | read-only | mandatory |
| pd1PowerTrendingSampleTimeStamp OBJECT-TYPE Power Domain 1 Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2 | OCTET STRING | read-only | mandatory |
| pd1PowerTrendingSampleAve OBJECT-TYPE Power Domain 1 Power Trending Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3 | OCTET STRING | read-only | mandatory |
| moduleInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4 | |||
| bladeDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.1 | |||
| bladeDetailsTable OBJECT-TYPE Table of Blade Module Details. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1 | not-accessible | mandatory | |
| bladeDetailsEntry OBJECT-TYPE Blade Module Details entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1 | not-accessible | mandatory | |
| bladeDetailsIndex OBJECT-TYPE Blade Module Details Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1 | INTEGER | read-only | mandatory |
| bladeDetailsId OBJECT-TYPE Blade Module Details Table Blade Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeDetailsMaxPowerConfig OBJECT-TYPE Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. Blade must be powered on to set this value. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3 | INTEGER | read-write | mandatory |
| bladeDetailsEffectiveClockRate OBJECT-TYPE Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4 | OCTET STRING | read-only | mandatory |
| bladeDetailsMaximumClockRate OBJECT-TYPE Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5 | OCTET STRING | read-only | mandatory |
| bladeDetailsPowerSaverMode OBJECT-TYPE When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsDynamicPowerSaver OBJECT-TYPE When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsDynamicPowerFavorPerformanceOverPower OBJECT-TYPE When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsPowerControl OBJECT-TYPE This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9 | INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)} | read-write | mandatory |
| bladeDetailsPcapMin OBJECT-TYPE Blade Module Details Table power capping Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.10 | OCTET STRING | read-only | mandatory |
| bladeDetailsPcapGuaranteedMin OBJECT-TYPE Blade Module Details Table power capping Guaranteed Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.11 | OCTET STRING | read-only | mandatory |
| bladeDetailsPcapMax OBJECT-TYPE Blade Module Details Table power capping Maximum value in watts. The blade must support the advanced power management feature. If the value is '<max1> Watts,<max2> Watts', which means, - if bladeDetailsDynamicPowerSaver is enabled, it is <max2> - otherwise it is <max1> If the value of Pcap Max is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.12 | OCTET STRING | read-only | mandatory |
| bladePowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3 | |||
| bladePowerTrendingPeriod OBJECT-TYPE Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module. Since the power trending data is constantly being computed and saved in the management application database, some queries of the bladePowerTrendingSampleTable may not provide information for a very short window of time. If the table returns empty, please wait a short period and retry the query. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| bladePowerTrendingBladeId OBJECT-TYPE Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-write | mandatory |
| bladePowerTrendingTopologyPath OBJECT-TYPE The topology Path is a location identifier for a blade. The chassis and each installed blade is represented by a hardware topology tree, where each node in the tree represents a blade. The path to a particular blade consists of one or more <blade>,<instance> pairs, where each successive pair is a child of the previous parent pair. This topology path is used to identify blades such as blade storage devices. Some examples. A storage blade with a controller card plugged into slot 1 topology location would be represented as : 010103010301--> Storage Controller card #1 of Sub-Chassis #1 A storage blade with a controller card plugged into slot 2 topology location would be represented as : 010103010302--> Storage Controller card #2 of Sub-Chassis #1 | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.3 | OCTET STRING (SIZE(0..100)) | read-write | mandatory |
| bladePowerTrendingSampleTable OBJECT-TYPE Table of Blade Module Power Trending Information. Since the power trending data is constantly being computed and saved in the management application database, some queries of this table may not provide information for a very short window of time. If the table data returns empty,please wait a short period and retry the query. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10 | not-accessible | mandatory | |
| bladePowerTrendingSampleEntry OBJECT-TYPE Blade Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1 | not-accessible | mandatory | |
| bladePowerTrendingSampleIndex OBJECT-TYPE Blade Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1 | INTEGER | read-only | mandatory |
| bladePowerTrendingSampleId OBJECT-TYPE Blade Module Power Trending Sample Table Blade Id. If the blade is defined using a topology location by using the scalar bladePowerTrendingTopologyPath, a zero will be displayed in the bladePowerTrendingSampleId. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladePowerTrendingSampleTimeStamp OBJECT-TYPE Blade Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleMax OBJECT-TYPE Blade Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleMin OBJECT-TYPE Blade Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleAve OBJECT-TYPE Blade Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleTopologyId OBJECT-TYPE Blade module topology path. This field will have a topology location when a blade is a storage blade or a blade defined with a sub chassis. If the blade is defined with a primary slot location by using the scalar bladePowerTrendingBladeId, 'not applicable' will be displayed in the bladePowerTrendingSampleTopologyId. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.7 | OCTET STRING | read-only | mandatory |
| switchDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.2 | |||
| switchPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3 | |||
| switchPowerTrendingPeriod OBJECT-TYPE Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| switchPowerTrendingSwitchId OBJECT-TYPE Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2 | INTEGER {module1(1), module2(2), module3(3), module4(4)} | read-write | mandatory |
| switchPowerTrendingSampleTable OBJECT-TYPE Table of Switch Module Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10 | not-accessible | mandatory | |
| switchPowerTrendingSampleEntry OBJECT-TYPE Switch Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1 | not-accessible | mandatory | |
| switchPowerTrendingSampleIndex OBJECT-TYPE Switch Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1 | INTEGER | read-only | mandatory |
| switchPowerTrendingSampleId OBJECT-TYPE Switch Module Power Trending Sample Table Switch Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| switchPowerTrendingSampleTimeStamp OBJECT-TYPE Switch Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleMax OBJECT-TYPE Switch Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleMin OBJECT-TYPE Switch Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleAve OBJECT-TYPE Switch Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6 | OCTET STRING | read-only | mandatory |
| chassisFanDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.3 | |||
| chassisFanPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3 | |||
| chassisFanPowerTrendingPeriod OBJECT-TYPE Specify time period for chassis fan module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for chassis fan module. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| chassisFanPowerTrendingId OBJECT-TYPE Chass fan mModule power trending fan ID. NOTE: The ID should be configured before displaying the chassisFanPowerTrendingTable. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2 | INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)} | read-write | mandatory |
| chassisFanPowerTrendingSampleTable OBJECT-TYPE Table of chassis fan Module Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10 | not-accessible | mandatory | |
| chassisFanPowerTrendingSampleEntry OBJECT-TYPE Chassis fan Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1 | not-accessible | mandatory | |
| chassisFanPowerTrendingSampleIndex OBJECT-TYPE Chassis fan Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1 | INTEGER | read-only | mandatory |
| chassisFanPowerTrendingSampleId OBJECT-TYPE Chassis fan Module Power Trending Sample Table Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2 | INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)} | read-only | mandatory |
| chassisFanPowerTrendingSampleTimeStamp OBJECT-TYPE Chassis fan Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3 | OCTET STRING | read-only | mandatory |
| chassisFanPowerTrendingSampleMax OBJECT-TYPE Chassis fan Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4 | OCTET STRING | read-only | mandatory |
| chassisFanPowerTrendingSampleMin OBJECT-TYPE Chassis fan Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5 | OCTET STRING | read-only | mandatory |
| chassisFanPowerTrendingSampleAve OBJECT-TYPE Chassis fan Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6 | OCTET STRING | read-only | mandatory |
| chassisInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5 | |||
| chassisConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.1 | |||
| chassisTotalDCPowerAvailable OBJECT-TYPE Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.1 | OCTET STRING | read-only | mandatory |
| chassisTotalPowerInUsed OBJECT-TYPE Chassis total power being used, which displays the total power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis cooling devices) for the chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.2 | OCTET STRING | read-only | mandatory |
| chassisTotalThermalOutput OBJECT-TYPE Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total input power in use. (1 Watt = 3.412 BTU/hour). | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.3 | OCTET STRING | read-only | mandatory |
| chassisPowerService OBJECT-TYPE The chassis power service mode. NOTE: This MIB object is for BCS only. This object has been deprecated. See the object, powerModuleDescription, for similar information. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.5 | INTEGER {volt110(1), volt220(2), notAvailable(255)} | read-only | deprecated |
| chassisPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.3 | |||
| chassisPowerTrendingPeriod OBJECT-TYPE Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| chassisPowerTrendingSampleTable OBJECT-TYPE Table of Chassis Power Trending Sample Information in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10 | not-accessible | mandatory | |
| chassisPowerTrendingSampleEntry OBJECT-TYPE Chassis Power Trending Sample entry in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1 | not-accessible | mandatory | |
| chassisPowerTrendingSampleIndex OBJECT-TYPE Chassis Power Trending Sample Index in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1 | INTEGER | read-only | mandatory |
| chassisPowerTrendingSampleTimeStamp OBJECT-TYPE Chassis Power Trending Sample Timestamp in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2 | OCTET STRING | read-only | mandatory |
| chassisPowerTrendingSampleAve OBJECT-TYPE Chassis Power Trending Sample Average Power in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3 | OCTET STRING | read-only | mandatory |
| chassisThermalTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.5 | |||
| chassisThermalTrendingPeriod OBJECT-TYPE Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| rearLEDCardThermalTrendingTable OBJECT-TYPE Table of rear LED card Thermal Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10 | not-accessible | mandatory | |
| rearLEDCardThermalTrendingEntry OBJECT-TYPE Rear LED Card Thermal Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1 | not-accessible | mandatory | |
| rearLEDCardThermalTrendingIndex OBJECT-TYPE Rear LED Card Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1 | INTEGER | read-only | mandatory |
| rearLEDCardThermalTrendingTimeStamp OBJECT-TYPE Rear LED Card Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2 | OCTET STRING | read-only | mandatory |
| rearLEDCardThermalTrendingTemperatureAvg OBJECT-TYPE Rear LED Card Thermal Trending Table Average Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3 | OCTET STRING | read-only | mandatory |
| rearLEDCardThermalTrendingTemperatureMin OBJECT-TYPE Rear LED Card Thermal Trending Table Minumum Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.4 | OCTET STRING | read-only | mandatory |
| rearLEDCardThermalTrendingTemperatureMax OBJECT-TYPE Rear LED Card Thermal Trending Table Maximum Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.5 | OCTET STRING | read-only | mandatory |
| cfmThermalTrendingTable OBJECT-TYPE Table of Cubic Feet per Minute Thermal Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60 | not-accessible | mandatory | |
| cfmThermalTrendingEntry OBJECT-TYPE Chassis CFM Thermal Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1 | not-accessible | mandatory | |
| cfmThermalTrendingIndex OBJECT-TYPE Cubic Feet per Minute Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.1 | INTEGER | read-only | mandatory |
| cfmThermalTrendingTimeStamp OBJECT-TYPE Cubic Feet per Minute Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.2 | OCTET STRING | read-only | mandatory |
| cfmThermalTrendingCurrentCFM OBJECT-TYPE Cubic Feet per Minute Thermal Trending Table The Current CFM of air flow calculated at this sample time. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.3 | OCTET STRING | read-only | mandatory |
| cfmThermalTrendingMaxCFM OBJECT-TYPE Cubic Feet per Minute Thermal Trending Table The Maximum CFM of air flow the chassis can provide at this sample time. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.4 | OCTET STRING | read-only | mandatory |
| ehiThermalTrendingTable OBJECT-TYPE Table of Exhaust Heat Index Thermal Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70 | not-accessible | mandatory | |
| ehiThermalTrendingEntry OBJECT-TYPE Chassis Exhaust Heat Index Thermal Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1 | not-accessible | mandatory | |
| ehiThermalTrendingIndex OBJECT-TYPE Exhaust Heat Index Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.1 | INTEGER | read-only | mandatory |
| ehiThermalTrendingTimeStamp OBJECT-TYPE Chassis Exhaust Heat Index Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.2 | OCTET STRING | read-only | mandatory |
| ehiThermalTrendingMinEHI OBJECT-TYPE Chassis Exhaust Heat Index Thermal Trending Table Minimum Exhaust Heat Index since last reboot. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.3 | OCTET STRING | read-only | mandatory |
| ehiThermalTrendingMaxEHI OBJECT-TYPE Chassis Exhaust Heat Index Thermal Trending Table Maximum Exhaust Heat Index since last reboot. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.4 | OCTET STRING | read-only | mandatory |
| ehiThermalTrendingAvgEHI OBJECT-TYPE Chassis Exhaust Heat Index Thermal Trending Table Average of last 2 Exhaust Heat Index calculations since last reboot. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.5 | OCTET STRING | read-only | mandatory |
| powerPolicyInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.6 | |||
| powerPolicyTable OBJECT-TYPE Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1 | not-accessible | mandatory | |
| powerPolicyEntry OBJECT-TYPE Power Policy Entry | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1 | not-accessible | mandatory | |
| powerPolicyIndex OBJECT-TYPE The unique idenitifier of a row in the powerPolicyTable. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1 | INTEGER | read-only | mandatory |
| powerPolicyPowerDomainNumber OBJECT-TYPE The power domain number which this row is associated with. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2 | INTEGER {powerDomain1(1), powerDomain2(2)} | read-only | mandatory |
| powerPolicyName OBJECT-TYPE The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Blade Throttling Allowed Very similar to the Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one power source fails. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3 | OCTET STRING | read-only | mandatory |
| powerPolicyPwrSupplyFailureLimit OBJECT-TYPE The maximum number of power supplies that can fail in a chassis while still providing redundancy. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4 | INTEGER | read-only | mandatory |
| powerPolicyMaxPowerLimit OBJECT-TYPE The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5 | INTEGER | read-only | mandatory |
| powerPolicyEstimatedUtilization OBJECT-TYPE The estimated utilization (as a percentage) based on current power usage. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6 | INTEGER | read-only | mandatory |
| powerPolicyActivate OBJECT-TYPE When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the MM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| users OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.17 | |||
| mmUsers OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.17.1 | |||
| currentlyLoggedInTable OBJECT-TYPE Table of MM users currently logged in. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1 | not-accessible | mandatory | |
| currentlyLoggedInEntry OBJECT-TYPE MM users currently logged in entries. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1 | not-accessible | mandatory | |
| currentlyLoggedInEntryIndex OBJECT-TYPE Index for MM users currently logged in. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| currentlyLoggedInEntryUserId OBJECT-TYPE Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| currentlyLoggedInEntryAccMethod OBJECT-TYPE Access method for MM users currently logged in. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3 | OCTET STRING (SIZE(0..32)) | read-only | mandatory |
| vpdInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21 | |||
| chassisInfoVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.1 | |||
| chassisVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.1.1 | |||
| chassisVpdMachineType OBJECT-TYPE Machine type VPD information (from System BIOS). This field must be four alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.1 | OCTET STRING | read-write | deprecated |
| chassisVpdMachineModel OBJECT-TYPE Machine model VPD information (from System BIOS). This field must be three alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.2 | OCTET STRING | read-write | deprecated |
| chassisSerialNumber OBJECT-TYPE Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.3 | OCTET STRING | read-write | deprecated |
| chassisUUID OBJECT-TYPE Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.4 | OCTET STRING | read-write | deprecated |
| chassisManufacturingId OBJECT-TYPE Machine chassis manufacturing ID. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.5 | OCTET STRING | read-only | deprecated |
| chassisHardwareRevision OBJECT-TYPE Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.6 | INTEGER | read-only | deprecated |
| chassisFruNumber OBJECT-TYPE Machine chassis FRU number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.7 | OCTET STRING | read-only | deprecated |
| chassisManufDate OBJECT-TYPE Machine chassis manufacture date. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.8 | OCTET STRING | read-only | deprecated |
| chassisPartNumber OBJECT-TYPE Machine chassis part number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.9 | OCTET STRING | read-only | deprecated |
| chassisFruSerial OBJECT-TYPE Machine chassis FRU serial number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.10 | OCTET STRING | read-only | deprecated |
| chassisManufacturingIDNumber OBJECT-TYPE Machine chassis manufacturer ID Number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.11 | OCTET STRING | read-only | deprecated |
| chassisProductId OBJECT-TYPE Machine chassis product ID. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.12 | OCTET STRING | read-only | deprecated |
| chassisSubManufacturerId OBJECT-TYPE Machine chassis subsystem manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.13 | OCTET STRING | read-only | deprecated |
| chassisClei OBJECT-TYPE Machine chassis Common Language Equipment Identification (CLEI). | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.14 | OCTET STRING | read-only | deprecated |
| chassisHardwareRevisionString OBJECT-TYPE Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.16 | OCTET STRING | read-only | deprecated |
| mmHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.2 | |||
| mmHardwareVpdTable OBJECT-TYPE Table of the management module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1 | not-accessible | deprecated | |
| mmHardwareVpdEntry OBJECT-TYPE Management module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1 | not-accessible | deprecated | |
| mmHardwareVpdIndex OBJECT-TYPE Management module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1 | INTEGER | read-only | deprecated |
| mmHardwareVpdBayNumber OBJECT-TYPE Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdManufacturingId OBJECT-TYPE Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdFruNumber OBJECT-TYPE Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdHardwareRevision OBJECT-TYPE Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5 | INTEGER | read-only | deprecated |
| mmHardwareVpdUuid OBJECT-TYPE Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdManufDate OBJECT-TYPE Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdPartNumber OBJECT-TYPE Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdFruSerial OBJECT-TYPE Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdManufacturingIDNumber OBJECT-TYPE Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdProductId OBJECT-TYPE Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdSubManufacturerId OBJECT-TYPE Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdClei OBJECT-TYPE Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13 | OCTET STRING | read-only | deprecated |
| mmHardwareVpdHardwareRevisionString OBJECT-TYPE Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14 | OCTET STRING | read-only | deprecated |
| mmFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.3 | |||
| mmMainApplVpdTable OBJECT-TYPE Table of MM Firmware VPD. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1 | not-accessible | deprecated | |
| mmMainApplVpdEntry OBJECT-TYPE MM Firmware VPD entry. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1 | not-accessible | deprecated | |
| mmMainApplVpdIndex OBJECT-TYPE Firmware VPD index. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1 | INTEGER | read-only | deprecated |
| mmMainApplVpdName OBJECT-TYPE Firmware VPD name description. 'MM firmware' indicates the running firmware of the MM. 'MM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2 | OCTET STRING | read-only | deprecated |
| mmMainApplVpdBuildId OBJECT-TYPE Firmware VPD build identification. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3 | OCTET STRING | read-only | deprecated |
| mmMainApplVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4 | OCTET STRING | read-only | deprecated |
| mmMainApplVpdFilename OBJECT-TYPE Firmware VPD file name. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5 | OCTET STRING | read-only | deprecated |
| mmMainApplVpdBuildDate OBJECT-TYPE Firmware VPD build date. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.4 | |||
| bladeHardwareVpdTable OBJECT-TYPE Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1 | not-accessible | deprecated | |
| bladeHardwareVpdEntry OBJECT-TYPE Blade hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1 | not-accessible | deprecated | |
| bladeHardwareVpdIndex OBJECT-TYPE Blade hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1 | INTEGER | read-only | deprecated |
| bladeHardwareVpdBayNumber OBJECT-TYPE Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdManufacturingId OBJECT-TYPE Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdFruNumber OBJECT-TYPE Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdHardwareRevision OBJECT-TYPE Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5 | INTEGER | read-only | deprecated |
| bladeHardwareVpdSerialNumber OBJECT-TYPE Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdMachineType OBJECT-TYPE Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdUuid OBJECT-TYPE Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdManufDate OBJECT-TYPE Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdPartNumber OBJECT-TYPE Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdFruSerial OBJECT-TYPE Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdMachineModel OBJECT-TYPE Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdManufacturingIDNumber OBJECT-TYPE Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdProductId OBJECT-TYPE Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdSubManufacturerId OBJECT-TYPE Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdClei OBJECT-TYPE Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpdHardwareRevisionString OBJECT-TYPE Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdCardType OBJECT-TYPE Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20 | INTEGER {unknown(0), networkExpansion(1), storageExpansion(2), pciExpansion(3), genericExpansion(4)} | read-only | deprecated |
| bladeDaughterVpdManufacturingId OBJECT-TYPE Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdFruNumber OBJECT-TYPE Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdHardwareRevision OBJECT-TYPE Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23 | INTEGER | read-only | deprecated |
| bladeDaughterVpdSerialNumber OBJECT-TYPE Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdMachineType OBJECT-TYPE Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdUuid OBJECT-TYPE Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdManufDate OBJECT-TYPE Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdPartNumber OBJECT-TYPE Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdFruSerial OBJECT-TYPE Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdManufacturingIDNumber OBJECT-TYPE Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdProductId OBJECT-TYPE Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdSubManufacturerId OBJECT-TYPE Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdClei OBJECT-TYPE Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33 | OCTET STRING | read-only | deprecated |
| bladeDaughterVpdHardwareRevisionString OBJECT-TYPE Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34 | OCTET STRING | read-only | deprecated |
| bladeMACAddressVpdTable OBJECT-TYPE Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2 | not-accessible | mandatory | |
| bladeMACAddressVpdEntry OBJECT-TYPE Blade MAC address entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1 | not-accessible | mandatory | |
| bladeMACAddressVpdIndex OBJECT-TYPE Blade index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1 | INTEGER | read-only | mandatory |
| bladeMACAddress1Vpd OBJECT-TYPE Blade MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2 | OCTET STRING | read-only | mandatory |
| bladeMACAddress2Vpd OBJECT-TYPE Blade MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3 | OCTET STRING | read-only | mandatory |
| bladeMACAddress3Vpd OBJECT-TYPE Blade MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4 | OCTET STRING | read-only | mandatory |
| bladeMACAddress4Vpd OBJECT-TYPE Blade MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeMACAddress5Vpd OBJECT-TYPE Blade MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6 | OCTET STRING | read-only | mandatory |
| bladeMACAddress6Vpd OBJECT-TYPE Blade MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7 | OCTET STRING | read-only | mandatory |
| bladeMACAddress7Vpd OBJECT-TYPE Blade MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8 | OCTET STRING | read-only | mandatory |
| bladeMACAddress8Vpd OBJECT-TYPE Blade MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress1Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress2Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress3Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress4Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress5Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress6Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress7Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress8Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress1Vpd OBJECT-TYPE Blade side card MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress2Vpd OBJECT-TYPE Blade side card MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress3Vpd OBJECT-TYPE Blade side card MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress4Vpd OBJECT-TYPE Blade side card MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress5Vpd OBJECT-TYPE Blade side card MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress6Vpd OBJECT-TYPE Blade side card MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress7Vpd OBJECT-TYPE Blade side card MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress8Vpd OBJECT-TYPE Blade side card MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdTable OBJECT-TYPE Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5 | not-accessible | deprecated | |
| bladeExpCardVpdEntry OBJECT-TYPE Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1 | not-accessible | deprecated | |
| bladeExpCardVpdIndex OBJECT-TYPE Blade expansion card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1 | INTEGER | read-only | deprecated |
| bladeExpCardVpdBayNumber OBJECT-TYPE Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdManufacturingId OBJECT-TYPE Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdFruNumber OBJECT-TYPE Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdHardwareRevision OBJECT-TYPE Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5 | INTEGER | read-only | deprecated |
| bladeExpCardVpdSerialNumber OBJECT-TYPE Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdMachineType OBJECT-TYPE Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdUuid OBJECT-TYPE Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdManufDate OBJECT-TYPE Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdPartNumber OBJECT-TYPE Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdFruSerial OBJECT-TYPE Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdMachineModel OBJECT-TYPE Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdManufacturingIDNumber OBJECT-TYPE Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdProductId OBJECT-TYPE Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdSubManufacturerId OBJECT-TYPE Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdClei OBJECT-TYPE Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdBladeBayNumber OBJECT-TYPE Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19 | OCTET STRING | read-only | deprecated |
| bladeExpCardVpdCardTypeInfo OBJECT-TYPE Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21 | INTEGER {unknown(0), bladeEthernetExpCard(1), bladeFiberChannelExpCard(2), serialPortExpCard(3), bladeOpticalPassThrough(4), bladeInfinibandExpCard(5), bladeIscsiExpCard(6), bladeGenericExpCard(7), bladeNetworkCFFeExpCard(8), bladeSASConnectivityCard(9), bladeSATAConnectivityCard(10), bladeNetworkCFFzExpCard(11), bladeNetworkCNAExpCard(12)} | read-only | deprecated |
| bladeExpCardVpdHighSpeed OBJECT-TYPE Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | deprecated |
| bladeExpCardVpdHardwareRevisionString OBJECT-TYPE Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpdTable OBJECT-TYPE Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7 | not-accessible | deprecated | |
| bladeAndExpCardWwnGuidVpdEntry OBJECT-TYPE Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1 | not-accessible | deprecated | |
| bladeAndExpCardWwnGuidVpdIndex OBJECT-TYPE Blade or expansion card index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1 | INTEGER | read-only | deprecated |
| bladeAndExpCardWwnGuidVpdBayNumber OBJECT-TYPE Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpdName OBJECT-TYPE The name of the blade or expansion card. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpdBladeBayNumber OBJECT-TYPE For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpdType OBJECT-TYPE Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5 | INTEGER {notAvailable(0), wwn(1), guid(2), sas(3)} | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd1 OBJECT-TYPE Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd2 OBJECT-TYPE Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd3 OBJECT-TYPE Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd4 OBJECT-TYPE Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd5 OBJECT-TYPE Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd6 OBJECT-TYPE Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd7 OBJECT-TYPE Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12 | OCTET STRING | read-only | deprecated |
| bladeAndExpCardWwnGuidVpd8 OBJECT-TYPE Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdTable OBJECT-TYPE Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8 | not-accessible | deprecated | |
| bladeManagementCardVpdEntry OBJECT-TYPE Blade management card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1 | not-accessible | deprecated | |
| bladeManagementCardVpdIndex OBJECT-TYPE Blade management card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1 | INTEGER | read-only | deprecated |
| bladeManagementCardVpdBayNumber OBJECT-TYPE Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdManufacturingId OBJECT-TYPE Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdFruNumber OBJECT-TYPE Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdHardwareRevision OBJECT-TYPE Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5 | INTEGER | read-only | deprecated |
| bladeManagementCardVpdSerialNumber OBJECT-TYPE Blade management card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdMachineType OBJECT-TYPE Blade management card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdUuid OBJECT-TYPE Blade management card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdManufDate OBJECT-TYPE Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdPartNumber OBJECT-TYPE Blade management card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdFruSerial OBJECT-TYPE Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdMachineModel OBJECT-TYPE Blade management card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdManufacturingIDNumber OBJECT-TYPE Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdProductId OBJECT-TYPE Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdSubManufacturerId OBJECT-TYPE Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdClei OBJECT-TYPE Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16 | OCTET STRING | read-only | deprecated |
| bladeManagementCardVpdHardwareRevisionString OBJECT-TYPE Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17 | OCTET STRING | read-only | deprecated |
| bladeFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.5 | |||
| bladeBiosVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1 | not-accessible | deprecated | |
| bladeBiosVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1 | not-accessible | deprecated | |
| bladeBiosVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1 | INTEGER | read-only | deprecated |
| bladeBiosVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | deprecated |
| bladeBiosVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| bladeBiosVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | deprecated |
| bladeBiosVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5 | OCTET STRING | read-only | deprecated |
| bladeBiosVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6 | OCTET STRING | read-only | deprecated |
| bladeBiosVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7 | OCTET STRING | read-only | deprecated |
| bladeBiosVpdDate OBJECT-TYPE The date of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8 | OCTET STRING | read-only | deprecated |
| bladeBiosVpdLevelStatus OBJECT-TYPE The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9 | OCTET STRING | read-only | deprecated |
| bladeDiagsVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2 | not-accessible | deprecated | |
| bladeDiagsVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1 | not-accessible | deprecated | |
| bladeDiagsVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1 | INTEGER | read-only | deprecated |
| bladeDiagsVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | deprecated |
| bladeDiagsVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| bladeDiagsVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | deprecated |
| bladeDiagsVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5 | OCTET STRING | read-only | deprecated |
| bladeDiagsVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6 | OCTET STRING | read-only | deprecated |
| bladeDiagsVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7 | OCTET STRING | read-only | deprecated |
| bladeDiagsVpdDate OBJECT-TYPE The date of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8 | OCTET STRING | read-only | deprecated |
| bladeDiagsVpdLevelStatus OBJECT-TYPE The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9 | OCTET STRING | read-only | deprecated |
| bladeSysMgmtProcVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3 | not-accessible | deprecated | |
| bladeSysMgmtProcVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1 | not-accessible | deprecated | |
| bladeSysMgmtProcVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1 | INTEGER | read-only | deprecated |
| bladeSysMgmtProcVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | deprecated |
| bladeSysMgmtProcVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| bladeSysMgmtProcVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | deprecated |
| bladeSysMgmtProcVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5 | OCTET STRING | read-only | deprecated |
| bladeSysMgmtProcVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6 | OCTET STRING | read-only | deprecated |
| bladeSysMgmtProcVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7 | OCTET STRING | read-only | deprecated |
| bladeSysMgmtProcVpdLevelStatus OBJECT-TYPE The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8 | OCTET STRING | read-only | deprecated |
| smHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.6 | |||
| smHardwareVpdTable OBJECT-TYPE Table of the switch module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1 | not-accessible | deprecated | |
| smHardwareVpdEntry OBJECT-TYPE Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1 | not-accessible | deprecated | |
| smHardwareVpdIndex OBJECT-TYPE Switch module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1 | INTEGER | read-only | deprecated |
| smHardwareVpdBayNumber OBJECT-TYPE Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2 | OCTET STRING | read-only | deprecated |
| smHardwareVpdManufacturingId OBJECT-TYPE Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3 | OCTET STRING | read-only | deprecated |
| smHardwareVpdFruNumber OBJECT-TYPE Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4 | OCTET STRING | read-only | deprecated |
| smHardwareVpdHardwareRevision OBJECT-TYPE Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5 | INTEGER | read-only | deprecated |
| smHardwareVpdUuid OBJECT-TYPE Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8 | OCTET STRING | read-only | deprecated |
| smHardwareVpdManufDate OBJECT-TYPE Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9 | OCTET STRING | read-only | deprecated |
| smHardwareVpdPartNumber OBJECT-TYPE Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10 | OCTET STRING | read-only | deprecated |
| smHardwareVpdFruSerial OBJECT-TYPE Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11 | OCTET STRING | read-only | deprecated |
| smHardwareVpdManufacturingIDNumber OBJECT-TYPE Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12 | OCTET STRING | read-only | deprecated |
| smHardwareVpdProductId OBJECT-TYPE Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13 | OCTET STRING | read-only | deprecated |
| smHardwareVpdSubManufacturerId OBJECT-TYPE Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14 | OCTET STRING | read-only | deprecated |
| smHardwareVpdClei OBJECT-TYPE Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15 | OCTET STRING | read-only | deprecated |
| smHardwareVpdWwnGuid OBJECT-TYPE Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16 | OCTET STRING | read-only | deprecated |
| smHardwareVpdWwnGuidType OBJECT-TYPE The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17 | OCTET STRING | read-only | deprecated |
| smHardwareVpdWidth OBJECT-TYPE The width of the switch module hardware. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18 | INTEGER | read-only | deprecated |
| smHardwareVpdHardwareRevisionString OBJECT-TYPE Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20 | OCTET STRING | read-only | deprecated |
| smFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.7 | |||
| smMainAppVpdTable OBJECT-TYPE Switch module main application VPD information table. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1 | not-accessible | deprecated | |
| smMainAppVpdEntry OBJECT-TYPE Switch module main application VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1 | not-accessible | deprecated | |
| smMainAppVpdIndex OBJECT-TYPE Switch module main application VPD entry index. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1 | INTEGER | read-only | deprecated |
| smMainAppVpdId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | deprecated |
| smMainAppVpdExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| smMainAppVpdSwitchType OBJECT-TYPE Indicates the type of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4 | INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)} | read-only | deprecated |
| smMainApp1VpdBuildId OBJECT-TYPE Switch module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5 | OCTET STRING | read-only | deprecated |
| smMainApp1VpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6 | OCTET STRING | read-only | deprecated |
| smMainApp1VpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7 | OCTET STRING | read-only | deprecated |
| smMainApp2VpdBuildId OBJECT-TYPE Switch module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8 | OCTET STRING | read-only | deprecated |
| smMainApp2VpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9 | OCTET STRING | read-only | deprecated |
| smMainApp2VpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10 | OCTET STRING | read-only | deprecated |
| smMainApp3VpdBuildId OBJECT-TYPE I/O Module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11 | OCTET STRING | read-only | deprecated |
| smMainApp3VpdBuildDate OBJECT-TYPE I/O Module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12 | OCTET STRING | read-only | deprecated |
| smMainApp3VpdRevisionNumber OBJECT-TYPE I/O Module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13 | OCTET STRING | read-only | deprecated |
| smMainAppVpdSwitchSubType OBJECT-TYPE Indicates the subtype of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20 | INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)} | read-only | deprecated |
| smBootRomVpdTable OBJECT-TYPE Switch module boot ROM VPD information table. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2 | not-accessible | deprecated | |
| smBootRomVpdEntry OBJECT-TYPE Switch module boot ROM VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1 | not-accessible | deprecated | |
| smBootRomVpdIndex OBJECT-TYPE Switch module boot ROM VPD entry index. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1 | INTEGER | read-only | deprecated |
| smBootRomVpdId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | deprecated |
| smBootRomVpdExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| smBootRomVpdSwitchType OBJECT-TYPE Indicates the type of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4 | INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)} | read-only | deprecated |
| smBootRomVpdBuildId OBJECT-TYPE Switch module firmware build ID. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5 | OCTET STRING | read-only | deprecated |
| smBootRomVpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6 | OCTET STRING | read-only | deprecated |
| smBootRomVpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7 | OCTET STRING | read-only | deprecated |
| smBootRomVpdSwitchSubType OBJECT-TYPE Indicates the subtype of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8 | INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)} | read-only | deprecated |
| pmHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.8 | |||
| pmHardwareVpdTable OBJECT-TYPE Table of the power module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1 | not-accessible | deprecated | |
| pmHardwareVpdEntry OBJECT-TYPE Power module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1 | not-accessible | deprecated | |
| pmHardwareVpdIndex OBJECT-TYPE Power module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1 | INTEGER | read-only | deprecated |
| pmHardwareVpdBayNumber OBJECT-TYPE Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdManufacturingId OBJECT-TYPE Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdFruNumber OBJECT-TYPE Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdHardwareRevision OBJECT-TYPE Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5 | INTEGER | read-only | deprecated |
| pmHardwareVpdUuid OBJECT-TYPE Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdManufDate OBJECT-TYPE Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdPartNumber OBJECT-TYPE Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdFruSerial OBJECT-TYPE Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdManufacturingIDNumber OBJECT-TYPE Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdProductId OBJECT-TYPE Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdSubManufacturerId OBJECT-TYPE Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdClei OBJECT-TYPE Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15 | OCTET STRING | read-only | deprecated |
| pmHardwareVpdHardwareRevisionString OBJECT-TYPE Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.9 | |||
| rearLEDCardHardwareVpdManufacturingId OBJECT-TYPE Rear LED card hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.3 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdFruNumber OBJECT-TYPE Rear LED card hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.4 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdHardwareRevision OBJECT-TYPE Rear LED card hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.9.5 | INTEGER | read-only | deprecated |
| rearLEDCardHardwareVpdUuid OBJECT-TYPE Rear LED card hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.8 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdManufacturingIDNumber OBJECT-TYPE Rear LED card hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.9 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdProductId OBJECT-TYPE Rear LED card hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.10 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdSubManufacturerId OBJECT-TYPE Rear LED card hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.11 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdClei OBJECT-TYPE Rear LED card hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.12 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdHardwareRevisionString OBJECT-TYPE Rear LED card hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.9.17 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdManufDate OBJECT-TYPE Rear LED card hardware VPD Manufacture Date. | 1.3.6.1.4.1.2.3.51.2.2.21.9.18 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdPartNumber OBJECT-TYPE Rear LED card hardware VPD Part Number. | 1.3.6.1.4.1.2.3.51.2.2.21.9.19 | OCTET STRING | read-only | deprecated |
| rearLEDCardHardwareVpdFruSerial OBJECT-TYPE Rear LED card hardware VPD FRU Serial. | 1.3.6.1.4.1.2.3.51.2.2.21.9.20 | OCTET STRING | read-only | deprecated |
| chassisFanFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.12 | |||
| chassisFanControllerVPDTable OBJECT-TYPE Table of chassis fan controller firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1 | not-accessible | deprecated | |
| chassisFanControllerVPDEntry OBJECT-TYPE Chassis fan controller firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1 | not-accessible | deprecated | |
| chassisFanControllerVpdIndex OBJECT-TYPE Chassis fan controller firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1 | INTEGER | read-only | deprecated |
| chassisFanControllerVpdId OBJECT-TYPE The numeric chassis fan ID. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2 | INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)} | read-only | deprecated |
| chassisFanControllerVpdExists OBJECT-TYPE Indicates whether the chassis fan specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| chassisFanControllerVpdRevision OBJECT-TYPE The revision of the chassis fan controller firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.13 | |||
| chassisFanHardwareVpdTable OBJECT-TYPE Table of the chassis fan hardware components. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1 | not-accessible | deprecated | |
| chassisFanHardwareVpdEntry OBJECT-TYPE Chassis fan hardware VPD entry. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1 | not-accessible | deprecated | |
| chassisFanHardwareVpdIndex OBJECT-TYPE Chassis fan hardware VPD index. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1 | INTEGER | read-only | deprecated |
| chassisFanHardwareVpdBayNumber OBJECT-TYPE Chassis fan hardware VPD Bay number. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdManufacturingId OBJECT-TYPE Chassis fan hardware VPD manufacturing ID. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdFruNumber OBJECT-TYPE Chassis fan hardware VPD FRU number. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdHardwareRevision OBJECT-TYPE Chassis fan hardware VPD hardware revision. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5 | INTEGER | read-only | deprecated |
| chassisFanHardwareVpdUuid OBJECT-TYPE Chassis fan hardware VPD UUID. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdManufDate OBJECT-TYPE Chassis fan hardware VPD manufacture Date. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdPartNumber OBJECT-TYPE Chassis fan hardware VPD Part Number. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdFruSerial OBJECT-TYPE Chassis fan hardware VPD FRU serial number. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdManufacturingIDNumber OBJECT-TYPE Chassis fan hardware VPD manufacturer ID. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdProductId OBJECT-TYPE Chassis fan hardware VPD product ID. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdSubManufacturerId OBJECT-TYPE Chassis fan hardware VPD subsystem manufacturer ID. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdClei OBJECT-TYPE Chassis fan hardware VPD Common Language Equipment Identifier (CLEI). | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15 | OCTET STRING | read-only | deprecated |
| chassisFanHardwareVpdHardwareRevisionString OBJECT-TYPE Chassis fan hardware VPD hardware revision in string format. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16 | OCTET STRING | read-only | deprecated |
| pmFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.14 | |||
| pmControllerVPDTable OBJECT-TYPE Table of Power Module controller firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1 | not-accessible | deprecated | |
| pmControllerVPDEntry OBJECT-TYPE Power Module controller firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1 | not-accessible | deprecated | |
| pmControllerVpdIndex OBJECT-TYPE Power Module controller firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1 | INTEGER | read-only | deprecated |
| pmControllerVpdId OBJECT-TYPE The numeric Power Module ID. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2 | INTEGER {powerModule1(1), powerModule2(2), powerModule3(3), powerModule4(4), powerModule5(5), powerModule6(6)} | read-only | deprecated |
| pmControllerVpdExists OBJECT-TYPE Indicates whether the Power Module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| pmControllerVpdRevision OBJECT-TYPE The revision of the Power Module controller firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7 | OCTET STRING | read-only | deprecated |
| inventoryManagementActivityVpdTable OBJECT-TYPE Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22 | not-accessible | mandatory | |
| inventoryManagementActivityVpdEntry OBJECT-TYPE System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1 | not-accessible | mandatory | |
| componentLevelActivityVpdIndex OBJECT-TYPE System component level VPD activity log index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.1 | INTEGER | read-only | mandatory |
| componentLevelActivityVpdFruNumber OBJECT-TYPE System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.2 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdSerialNumber OBJECT-TYPE System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.3 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdManufacturingId OBJECT-TYPE System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.4 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdBayNumber OBJECT-TYPE System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.5 | OCTET STRING | read-only | deprecated |
| componentLevelActivityVpdAction OBJECT-TYPE System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.9 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdTimestamp OBJECT-TYPE System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.10 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdModuleName OBJECT-TYPE The module name which this row is associated with. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.12 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdTopologyPath OBJECT-TYPE The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. The topology path's numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.15 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| reloadVpdData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.23 | |||
| reloadAllVpdData OBJECT-TYPE Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.1 | INTEGER {execute(1)} | read-write | mandatory |
| reloadFwVpdData OBJECT-TYPE Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.2 | INTEGER {execute(1)} | read-write | mandatory |
| reloadHwVpdData OBJECT-TYPE Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.3 | INTEGER {execute(1)} | read-write | mandatory |
| reloadMACAddress OBJECT-TYPE Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.4 | INTEGER {execute(1)} | read-write | mandatory |
| reloadWwnGuidVpdData OBJECT-TYPE Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.5 | INTEGER {execute(1)} | read-write | mandatory |
| airFilter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.22 | |||
| passiveAirFilter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.22.1 | |||
| passiveAirFilterStatus OBJECT-TYPE Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. | 1.3.6.1.4.1.2.3.51.2.2.22.1.1 | INTEGER {disabled(0), enabled(1), reset(2)} | read-write | mandatory |
| passiveAirFilterMonthFreq OBJECT-TYPE The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. | 1.3.6.1.4.1.2.3.51.2.2.22.1.2 | INTEGER {oneMonth(1), threeMonths(3), sixMonths(6)} | read-write | mandatory |
| passiveAirFilterReplaceDate OBJECT-TYPE The scheduled replacement date of the air filter. | 1.3.6.1.4.1.2.3.51.2.2.22.1.3 | OCTET STRING (SIZE(0..30)) | read-only | mandatory |
| componentInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23 | |||
| componentInventory OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23.1 | |||
| componentInventoryTable OBJECT-TYPE Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. Also, if a component does not have inventory information or the CMM is not able to read the data from the device, then there will not be a row in this table for the component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1 | not-accessible | mandatory | |
| componentInventoryEntry OBJECT-TYPE Component inventory information. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1 | not-accessible | mandatory | |
| componentInventoryTopologyPath OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentInventoryInstance OBJECT-TYPE The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2 | INTEGER | read-only | mandatory |
| componentInventoryDescription OBJECT-TYPE A short text string describing the particular component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object in this table or the componentXXXXName object of any of the other component tables under the 'components' section of the MIB. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3 | OCTET STRING | read-only | mandatory |
| componentInventoryMachineTypeModel OBJECT-TYPE The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4 | OCTET STRING | read-only | mandatory |
| componentInventoryMachineSerial OBJECT-TYPE The machine serial number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5 | OCTET STRING | read-only | mandatory |
| componentInventoryAssetID OBJECT-TYPE The asset identifier of this component, typically set by some other authority than the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6 | OCTET STRING | read-only | mandatory |
| componentInventoryPartNumber OBJECT-TYPE The part number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7 | OCTET STRING | read-only | mandatory |
| componentInventoryFRUNumber OBJECT-TYPE The Field Replaceable Unit (FRU) number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8 | OCTET STRING | read-only | mandatory |
| componentInventoryFRUSerialNumber OBJECT-TYPE The Field Replaceable Unit (FRU) serial number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9 | OCTET STRING | read-only | mandatory |
| componentInventoryManufacture OBJECT-TYPE The text description of the manufacturer of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10 | OCTET STRING | read-only | mandatory |
| componentInventoryHardwareRevision OBJECT-TYPE The hardware revision number of the this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11 | OCTET STRING | read-only | mandatory |
| componentInventoryManufactureDate OBJECT-TYPE The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12 | OCTET STRING | read-only | mandatory |
| componentInventoryUUID OBJECT-TYPE The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13 | OCTET STRING | read-only | mandatory |
| componentInventoryProductID OBJECT-TYPE The product identifier of the component assigned by the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14 | OCTET STRING | read-only | mandatory |
| componentInventorySubManufactureID OBJECT-TYPE The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15 | OCTET STRING | read-only | mandatory |
| componentInventoryCLEI OBJECT-TYPE The Common Language Equipment Identifier (CLEI) of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16 | OCTET STRING | read-only | mandatory |
| componentInventoryAssetTag OBJECT-TYPE The asset tag of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17 | OCTET STRING | read-only | mandatory |
| componentInventorySpeed OBJECT-TYPE A speed designation for the component, for example, processor speed. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18 | OCTET STRING | read-only | mandatory |
| componentInventoryIdentifier OBJECT-TYPE A unique identifier assigned by the manufacturer to the component, for example, a processor ID. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19 | OCTET STRING | read-only | mandatory |
| componentInventorySize OBJECT-TYPE A size designation for the component, for example, a memory DIMM size or hard drive capacity. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20 | INTEGER | read-only | mandatory |
| componentInventoryMemoryType OBJECT-TYPE The architecture specification of a memory device. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21 | INTEGER {fpmdram(1), edo(2), edodram(3), sdram(4), multiplexedram(5), ddrsgram(6), ddrsdram(7), ddr2sdrm(8), ddr3sdram(11)} | read-only | mandatory |
| componentInventoryProductName OBJECT-TYPE The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22 | OCTET STRING | read-only | mandatory |
| componentInventoryProductVersion OBJECT-TYPE The product version assigned by the manufacturer for this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorType OBJECT-TYPE The type designation for processor components. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24 | INTEGER {other(1), unknown(2), central(3), math(4), dsp(5), video(6)} | read-only | mandatory |
| componentInventoryProcessorFamily OBJECT-TYPE The family designation for processor components. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorCores OBJECT-TYPE The number of cores present on a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorThreads OBJECT-TYPE The number of threads present on a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL1DCache OBJECT-TYPE The level 1 data cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL1ICache OBJECT-TYPE The level 1 instruction cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL2Cache OBJECT-TYPE The level 2 cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL3Cache OBJECT-TYPE The level 3 cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorVoltage OBJECT-TYPE The voltage rating for a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorExtClock OBJECT-TYPE The external clock speed of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorDataWidth OBJECT-TYPE The maximum data bus width capability of a processor component, expressed typically in bits. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34 | OCTET STRING | read-only | mandatory |
| componentInventoryManufactureIDNum OBJECT-TYPE The identification number assigned for the component by the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35 | INTEGER | read-only | mandatory |
| componentInventoryGlobalID OBJECT-TYPE The global identifier (GLID) of this component. This ID is a unique identifier for the CMM chassis (midplane), set by the manufacturer. This ID and the associated inventory is passed back to IBM via the Electronic Service Agent and the Call Home feature. This ID and the accompanying chassis inventory will be stored and retained resulting in a configuration/change history file of the inventory for a chassis associated with a particular GLID. This ID can be used by a customer to identify and categorize all the content that resides within a chassis, much like a physical serial number is associated with a single box server. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.41 | OCTET STRING | read-only | mandatory |
| componentInventoryTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentInventoryTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.2.23.1.2 | INTEGER | read-only | mandatory |
| componentFirmware OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23.2 | |||
| componentFirmwareTable OBJECT-TYPE Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1 | not-accessible | mandatory | |
| componentFirmwareEntry OBJECT-TYPE Component firmware information. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1 | not-accessible | mandatory | |
| componentFirmwareTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentFirmwareIndex OBJECT-TYPE Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2 | INTEGER | read-only | mandatory |
| componentFirmwareComponentInstance OBJECT-TYPE The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3 | INTEGER | read-only | mandatory |
| componentFirmwareComponentDescription OBJECT-TYPE A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4 | OCTET STRING | read-only | mandatory |
| componentFirmwareType OBJECT-TYPE A text description of the type of firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5 | OCTET STRING | read-only | mandatory |
| componentFirmwareBuildID OBJECT-TYPE A text description of the build identifier for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6 | OCTET STRING | read-only | mandatory |
| componentFirmwareReleaseDate OBJECT-TYPE A text description of the release date for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7 | OCTET STRING | read-only | mandatory |
| componentFirmwareFilename OBJECT-TYPE A text description of the filename of this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8 | OCTET STRING | read-only | mandatory |
| componentFirmwareRevision OBJECT-TYPE A text description of the revision level of this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9 | OCTET STRING | read-only | mandatory |
| componentFirmwareRevisionMajor OBJECT-TYPE A numeric identifier of the revision major number for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10 | INTEGER | read-only | mandatory |
| componentFirmwareRevisionMinor OBJECT-TYPE A numeric identifier of the revision minor number for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11 | INTEGER | read-only | mandatory |
| componentFirmwareLevelStatus OBJECT-TYPE The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingBuildID OBJECT-TYPE A text description of the build identifier for this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingReleaseDate OBJECT-TYPE A text description of the release date for this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingRevision OBJECT-TYPE A text description of the revision level of this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15 | OCTET STRING | read-only | mandatory |
| componentFirmwareReleaseLevel OBJECT-TYPE A text description of the firmware release level this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.16 | OCTET STRING | read-only | mandatory |
| componentFirmwareImageStatus OBJECT-TYPE This object indicates whether this firmware image is the active (1) firmware,otherwise this firmware image is inactive (0). | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.17 | INTEGER {inactive(0), active(1), na(255)} | read-only | mandatory |
| componentFirmwareRole OBJECT-TYPE A text description with the firmware image information. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.18 | OCTET STRING | read-only | mandatory |
| componentFirmwareTypeID OBJECT-TYPE Indicates the type of firmware load with a numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20 | INTEGER {bladeFwBios(1), bladeDiagnostics(2), bladeSysMgmtProcessor(3), bladeFpga(4), bladecKVM(5), bladeMP(6), bladeUEFI(7), bladeDSA(8), switchModuleMainAppl(40), switchModuleMainAppl1(41), switchModuleMainAppl2(42), switchModuleBootROM(43), mgmtModuleMainAppl(61), mgmtModuleMainApplPendingRestart(62), fanController(81), powerSupplyFirmware(91), powerSupplyFanController(92), expansionCardGeneric(101), expansionCardEfi(102), expansionCardFcode(103), expansionCardBios(104), expansionCardMain(105), expansionCardMulti(106), unknown(255)} | read-only | mandatory |
| componentFirmwareTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentFirmwareTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.2.23.2.2 | INTEGER | read-only | mandatory |
| nodeFirmwareAnalysisTable OBJECT-TYPE Table of firmware levels of installed nodes. This information is grouped by Machine Type/Model and includes two or more nodes with the same Type/Model. This information is intended to be used in determining which components firmware may need upgrade. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7 | not-accessible | mandatory | |
| nodeFirmwareAnalysisEntry OBJECT-TYPE Node firmware analysis information. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1 | not-accessible | mandatory | |
| nodeFirmwareAnalysisIndex OBJECT-TYPE The index for the node firmware levels. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.1 | INTEGER | read-only | mandatory |
| nodeFirmwareAnalysisMachineTypeModel OBJECT-TYPE The machine type or model of node firmware. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.2 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisFirmwareType OBJECT-TYPE The firmware type. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.3 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisBuildId OBJECT-TYPE The firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.4 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisReleaseDate OBJECT-TYPE The firmware release date. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.5 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisRevisionLevel OBJECT-TYPE The firmware revision level. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.6 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisTopology OBJECT-TYPE The node topology. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.7 | OCTET STRING | read-only | mandatory |
| nodeFirmwareAnalysisDeviceName OBJECT-TYPE The node device name. | 1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.8 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisTable OBJECT-TYPE Table of firmware levels of installed IOMs. This information is grouped by Product Id and includes two or more IOMs with the same product id. This information is intended to be used in determining which components firmware may need upgrade. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11 | not-accessible | mandatory | |
| smFirmwareAnalysisEntry OBJECT-TYPE IOM firmware analysis information. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1 | not-accessible | mandatory | |
| smFirmwareAnalysisIndex OBJECT-TYPE The index for the IOM firmware levels. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.1 | INTEGER | read-only | mandatory |
| smFirmwareAnalysisProductId OBJECT-TYPE The IOM product id. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.2 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisProductName OBJECT-TYPE The IOM product name. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.3 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisFirmwareType OBJECT-TYPE The IOM firmware type. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.4 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisFirmwareVersion OBJECT-TYPE The IOM firmware version. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.5 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisReleaseDate OBJECT-TYPE The IOM release date. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.6 | OCTET STRING | read-only | mandatory |
| smFirmwareAnalysisTopology OBJECT-TYPE The IOM topology. | 1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.7 | OCTET STRING | read-only | mandatory |
| componentInventoryReady OBJECT-TYPE When a blade management controller, switch or the MM is reset, the inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades and switches have completed initialization and the inventory information has been provided to the MM. Note that due to components that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout A more granular, per-blade status is available via the bladeSystemStatusTable | 1.3.6.1.4.1.2.3.51.2.2.23.3 | INTEGER {notReady(0), ready(1)} | read-only | mandatory |
| componentDriveTable OBJECT-TYPE Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table. | 1.3.6.1.4.1.2.3.51.2.2.23.10 | not-accessible | mandatory | |
| componentDriveEntry OBJECT-TYPE Component drive information. | 1.3.6.1.4.1.2.3.51.2.2.23.10.1 | not-accessible | mandatory | |
| componentDriveTopologyPath OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentDriveDescription OBJECT-TYPE A short text string describing the particular drive on the component. | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.2 | OCTET STRING | read-only | mandatory |
| componentDriveTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentDriveTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.2.23.11 | INTEGER | read-only | mandatory |
| licenseKeyInfo OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.30 | |||
| licenseKeyInfoTable OBJECT-TYPE Table of license key information. | 1.3.6.1.4.1.2.3.51.2.2.30.1 | not-accessible | mandatory | |
| licenseKeyInfoEntry OBJECT-TYPE License key information entry. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1 | not-accessible | mandatory | |
| licenseKeyComponentIndex OBJECT-TYPE License key component table index. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.1 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14), switchModule1(41), switchModule2(42), switchModule3(43), switchModule4(44)} | read-only | mandatory |
| licenseKeyIndex OBJECT-TYPE The license key index for the chassis component. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.2 | INTEGER (1..255) | read-only | mandatory |
| licenseKeyDescription OBJECT-TYPE The description for a license key. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.3 | OCTET STRING | read-only | mandatory |
| licenseKeyTimestamp OBJECT-TYPE The date and time of this license key. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.4 | OCTET STRING | read-only | mandatory |
| licenseKeyLicenseID OBJECT-TYPE The unique identifier for this license key. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.5 | OCTET STRING | read-only | mandatory |
| licenseKeyOtherInfo OBJECT-TYPE Any other information related to this license key. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.6 | OCTET STRING | read-only | mandatory |
| licenseKeyStatus OBJECT-TYPE The current status of this license key. | 1.3.6.1.4.1.2.3.51.2.2.30.1.1.7 | INTEGER {unknown(0), valid(1), invalid(2), expired(3), usageExceeded(4), notApplicable(99)} | read-only | mandatory |
| chassisLicenseKeyTable OBJECT-TYPE Table of chassis license key information. | 1.3.6.1.4.1.2.3.51.2.2.30.5 | not-accessible | mandatory | |
| chassisLicenseKeyEntry OBJECT-TYPE Chassis License key information entry. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1 | not-accessible | mandatory | |
| chassisLicenseKeyIndex OBJECT-TYPE The key index for the chassis license keys. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.1 | INTEGER (1..255) | read-only | mandatory |
| chassisLicenseKeyFeature OBJECT-TYPE The name of the Feature for the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.2 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyFeatureType OBJECT-TYPE The Feature Type Code for the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.3 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyDescription OBJECT-TYPE The description of the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.4 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeySystem OBJECT-TYPE System information for the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.5 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyLicenseID OBJECT-TYPE Identification of the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.6 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyValidation OBJECT-TYPE Validation of the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.7 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyStatus OBJECT-TYPE The current status of the license key. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.8 | INTEGER {valid(0), validatingKey(1), invalidMTSN(2), invalidMAC(3), signatureValidationFailed(4), keyExpired(5), usageExceeded(6), validateElsewhere(7), notApplicable(8)} | read-only | mandatory |
| chassisLicenseKeyTimeLimit OBJECT-TYPE Date and Time (GMT) when license expires. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.9 | OCTET STRING | read-only | mandatory |
| chassisLicenseKeyUsageLimit OBJECT-TYPE Number of times remaining for license usage. A negative value indicates that there is no Usage Limit for the license. | 1.3.6.1.4.1.2.3.51.2.2.30.5.1.10 | INTEGER | read-only | mandatory |
| errorLogs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.3 | |||
| eventLog OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.3.4 | |||
| readEventLogTable OBJECT-TYPE Table of event log entry information. | 1.3.6.1.4.1.2.3.51.2.3.4.2 | not-accessible | mandatory | |
| readEventLogEntry OBJECT-TYPE Event log table entry | 1.3.6.1.4.1.2.3.51.2.3.4.2.1 | not-accessible | mandatory | |
| readEventLogIndex OBJECT-TYPE The event log index number. | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.1 | INTEGER | read-only | mandatory |
| readEventLogString OBJECT-TYPE A string of data detailing an event. | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.2 | OCTET STRING | read-only | mandatory |
| clearEventLog OBJECT-TYPE Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.3 | INTEGER {execute(1)} | read-write | mandatory |
| monitorLogStateEvents OBJECT-TYPE If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out. | 1.3.6.1.4.1.2.3.51.2.3.4.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| readEnhancedEventLogTable OBJECT-TYPE Table of enhanced event log entry information. | 1.3.6.1.4.1.2.3.51.2.3.4.6 | not-accessible | mandatory | |
| readEnhancedEventLogEntry OBJECT-TYPE Enhaced Event log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1 | not-accessible | mandatory | |
| readEnhancedEventLogNumber OBJECT-TYPE The event log number for the enhanced event log. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.1 | Unsigned32 (0..4294967295) | read-only | mandatory |
| readEnhancedEventLogAttribute OBJECT-TYPE A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.2 | OCTET STRING | read-only | mandatory |
| readEnhancedEventLogMessage OBJECT-TYPE A string of data detailing an event log message. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.3 | OCTET STRING | read-only | mandatory |
| readEnhancedEventLogSequenceNum OBJECT-TYPE The sequence number for the enhanced event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.4 | Unsigned32 (0..4294967295) | read-only | mandatory |
| readAuditLogTable OBJECT-TYPE Table of audit log entry information. Audit log includes the logs whose source is 'Audit' | 1.3.6.1.4.1.2.3.51.2.3.4.10 | not-accessible | mandatory | |
| readAuditLogEntry OBJECT-TYPE Audit log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1 | not-accessible | mandatory | |
| readAuditLogNumber OBJECT-TYPE The audit log number. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.1 | Unsigned32 (0..4294967295) | read-only | mandatory |
| readAuditLogAttribute OBJECT-TYPE A string of data detailing an audit eventlog's attribute. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.2 | OCTET STRING | read-only | mandatory |
| readAuditLogMessage OBJECT-TYPE A string of data detailing an audit event log message. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.3 | OCTET STRING | read-only | mandatory |
| readAuditLogSequenceNum OBJECT-TYPE The sequence number for the audit event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.4 | Unsigned32 (0..4294967295) | read-only | mandatory |
| clearAuditLog OBJECT-TYPE Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.11 | INTEGER {execute(1)} | read-write | mandatory |
| readSystemLogTable OBJECT-TYPE Table of system log entry information. System log includes the logs whose source is other than 'Audit' | 1.3.6.1.4.1.2.3.51.2.3.4.12 | not-accessible | mandatory | |
| readSystemLogEntry OBJECT-TYPE System log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1 | not-accessible | mandatory | |
| readSystemLogNumber OBJECT-TYPE The system log index number. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.1 | Unsigned32 (0..4294967295) | read-only | mandatory |
| readSystemLogAttribute OBJECT-TYPE A string of data detailing an system event log's attribute. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.2 | OCTET STRING | read-only | mandatory |
| readSystemLogMessage OBJECT-TYPE A string of data detailing an system event log message. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.3 | OCTET STRING | read-only | mandatory |
| readSystemLogSequenceNum OBJECT-TYPE The sequence number for the system event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.4 | Unsigned32 (0..4294967295) | read-only | mandatory |
| clearSystemLog OBJECT-TYPE Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.13 | INTEGER {execute(1)} | read-write | mandatory |
| readEventLogAuxTable OBJECT-TYPE Table of system log entry auxiliary information. | 1.3.6.1.4.1.2.3.51.2.3.4.14 | not-accessible | mandatory | |
| readEventLogAuxEntry OBJECT-TYPE Event log auxiliary table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.14.1 | not-accessible | mandatory | |
| readEventLogAuxNumber OBJECT-TYPE The system log auxiliary index number. To relate this information to the system log, match Sequence number of this entry to the Sequence number of the system log entry. | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.1 | INTEGER | read-only | mandatory |
| readEventLogAuxSequenceNum OBJECT-TYPE The sequence number for the system event log that contains this Auxiliary information. Value is from 1 through 4294967295 and then wraps. | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.2 | Unsigned32 (0..4294967295) | read-only | mandatory |
| readEventLogAuxMessage OBJECT-TYPE A string of data detailing the auxiliary information from the log event. | 1.3.6.1.4.1.2.3.51.2.3.4.14.1.3 | OCTET STRING | read-only | mandatory |
| configureSP OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4 | |||
| remoteAccessConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1 | |||
| generalRemoteCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1 | |||
| remoteAlertRetryDelay OBJECT-TYPE Number in seconds to delay between retries if sending a remote alert is unsuccessful. | 1.3.6.1.4.1.2.3.51.2.4.1.1.3 | INTEGER {oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)} | read-write | mandatory |
| remoteAlertRetryCount OBJECT-TYPE Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted. | 1.3.6.1.4.1.2.3.51.2.4.1.1.4 | INTEGER {noretry(0), retry1(1), retry2(2), retry3(3), retry4(4), retry5(5), retry6(6), retry7(7), retry8(8)} | read-write | mandatory |
| userAuthenticationMethod OBJECT-TYPE Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified. | 1.3.6.1.4.1.2.3.51.2.4.1.1.7 | INTEGER {localOnly(0), ldapOnly(1), localFirstThenLdap(2), ldapFirstThenLocal(3)} | read-write | mandatory |
| maxSessionsPerLDAPUser OBJECT-TYPE The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | 1.3.6.1.4.1.2.3.51.2.4.1.1.9 | INTEGER | read-write | mandatory |
| authenticationLoggingTimeout OBJECT-TYPE Use this option to set how long, in seconds, MM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events. | 1.3.6.1.4.1.2.3.51.2.4.1.1.10 | INTEGER {logAll(0), fiveSeconds(1), thirtySeconds(2), oneMinute(3), fiveMinutes(4), tenMinutes(5), thirtyMinutes(6), oneHour(7), twelveHours(8), oneDay(9), logNone(255)} | read-write | mandatory |
| trackingIP OBJECT-TYPE This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'. | 1.3.6.1.4.1.2.3.51.2.4.1.1.11 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| accountSecurityManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1.20 | |||
| accountSecurityLevel OBJECT-TYPE The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.1 | INTEGER {legacy(0), high(1), custom(2)} | read-write | mandatory |
| customSecuritySettings OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2 | |||
| passwordExpirationPeriod OBJECT-TYPE The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2 | INTEGER | read-write | mandatory |
| defaultAdminPasswordExpired OBJECT-TYPE If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| minimumPasswordReuseCycle OBJECT-TYPE The number of unique passwords a user must choose before reusing a password. The default value is none. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4 | INTEGER {none(0), onePassword(1), twoPasswords(2), threePasswords(3), fourPasswords(4), fivePasswords(5)} | read-write | mandatory |
| complexPasswordRules OBJECT-TYPE If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The complex rules are as follows: must be 8-31 characters must contain at least one number must contain at least one letter cannot contain white space characters cannot be a repeat or reverse of user name no more than 3 of the same characters used consecutively must contain at least 2 of the following combinations: at least one upper case letter at least one lower case letter at least one special character Password and password confirm values must match If disabled, the lagacy rules are: must be 5-31 characters must contain at least one number must contain at least one letter cannot contain white space characters Password and password confirm values must match The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| minimumDiffCharsPassword OBJECT-TYPE The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0) | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6 | INTEGER {none(0), oneChar(1), twoChars(2), threeChars(3), fourChars(4), fiveChars(5), sixChars(6), sevenChars(7), eightChars(8), nineChars(9), tenChars(10), elevenChars(11), twelveChars(12), thirteenChars(13), fourteenChars(14), fifteenChars(15)} | read-write | mandatory |
| changePasswordFirstAccess OBJECT-TYPE If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| inactivityAlertPeriod OBJECT-TYPE The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8 | INTEGER | read-write | mandatory |
| inactivityAlertDisablePeriod OBJECT-TYPE The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9 | INTEGER | read-write | mandatory |
| lockoutPeriod OBJECT-TYPE The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10 | INTEGER | read-write | mandatory |
| maxLoginFailures OBJECT-TYPE The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11 | INTEGER {none(0), oneTime(1), twoTimes(2), threeTimes(3), fourTimes(4), fiveTimes(5), sixTimes(6), sevenTimes(7), eightTimes(8), nineTimes(9), tenTimes(10)} | read-write | mandatory |
| passwordChangeInterval OBJECT-TYPE A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12 | INTEGER | read-write | mandatory |
| serialPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.2 | |||
| portBaud OBJECT-TYPE Baud rate for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.1 | INTEGER {baud2400(0), baud4800(1), baud9600(3), baud19200(7), baud38400(15), baud57600(23), baud115200(47)} | read-write | mandatory |
| portParity OBJECT-TYPE Parity setting for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.2 | INTEGER {none(0), odd(1), even(3), mark(5), space(7)} | read-write | mandatory |
| portStopBits OBJECT-TYPE Number of stop bits for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.3 | INTEGER {oneStopbit(0), twoOrOnePtFive(1)} | read-write | mandatory |
| remoteAlertIds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.3 | |||
| remoteAlertIdsTable OBJECT-TYPE Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1 | not-accessible | mandatory | |
| remoteAlertIdsEntry OBJECT-TYPE Remote alert entries. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1 | not-accessible | mandatory | |
| remoteAlertIdEntryIndex OBJECT-TYPE Index for remote alert entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1 | INTEGER | read-only | mandatory |
| remoteAlertIdEntryStatus OBJECT-TYPE Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2 | INTEGER {invalid(0), disabledAndValid(1), enabledAndValid(2)} | read-write | mandatory |
| remoteAlertIdEntryIpOrHostAddress OBJECT-TYPE A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3 | OCTET STRING (SIZE(0..50)) | read-write | mandatory |
| remoteAlertIdEntryTextDescription OBJECT-TYPE A null terminated string that contains a text description of this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4 | OCTET STRING (SIZE(0..50)) | read-write | mandatory |
| remoteAlertIdEntryNotificationType OBJECT-TYPE Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5 | INTEGER {unknown(0), snmpOverLan(4), emailOverLan(5)} | read-write | mandatory |
| remoteAlertIdEmailAddr OBJECT-TYPE A null terminated string that contains an E-Mail Address. For example, 'xyz@us.ibm.com'. Used only for an E-mail over LAN notification type. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| remoteAlertIdEntrySelectiveAlert OBJECT-TYPE Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13 | INTEGER {critOnlyAlerts(0), allAlerts(1)} | read-write | mandatory |
| generateTestAlert OBJECT-TYPE Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.3.30 | INTEGER {execute(1)} | read-write | mandatory |
| remoteAccessIds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.4 | |||
| remoteAccessIdsTable OBJECT-TYPE Table of remote access profiles. This table lets you to configure all login profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1 | not-accessible | mandatory | |
| remoteAccessIdsEntry OBJECT-TYPE Remote access entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1 | not-accessible | mandatory | |
| remoteAccessIdEntryIndex OBJECT-TYPE Index for Remote access entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| remoteAccessIdEntryUserId OBJECT-TYPE Remote access entry null terminated string that contains the userid. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2 | OCTET STRING (SIZE(0..33)) | read-write | mandatory |
| remoteAccessIdEntryPassword OBJECT-TYPE Remote access password. The password rules are dictated by a combination of the chassis security policy setting (securityPolicySetting) and the user account security level setting (accountSecurityLevel). Refer to object complexPasswordRules to understand the requirements. NOTE: Value returned by the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3 | OCTET STRING (SIZE(0..17)) | read-write | mandatory |
| remoteAccessIdEntryPermgroups OBJECT-TYPE A list of permission groups for this userid, delmited with a '|' | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10 | OCTET STRING | read-write | mandatory |
| remoteAccessIdEntryLoggedIn OBJECT-TYPE Indicates if user is currently logged in or not. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryLastLogin OBJECT-TYPE Timestamp for the last successful login by the user. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12 | OCTET STRING | read-only | mandatory |
| remoteAccessIdEntryPwdCompliant OBJECT-TYPE Indicates if user complies with all of the password rules currently in effect. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryPwdExp OBJECT-TYPE The number of days until the user's current password expires. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14 | OCTET STRING | read-only | mandatory |
| remoteAccessIdEntryDormant OBJECT-TYPE Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryState OBJECT-TYPE Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16 | INTEGER {disabled(0), active(1), locked(2)} | read-only | mandatory |
| remoteAccessIdEntryAction OBJECT-TYPE Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17 | INTEGER {disable(0), enable(1), unlock(2), notApplicable(255)} | read-write | mandatory |
| remoteAccessIdEntrySessionCount OBJECT-TYPE The number of sessions the user is currently logged in to. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18 | INTEGER | read-only | mandatory |
| remoteAccessIdEntryMaxSessions OBJECT-TYPE The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19 | INTEGER | read-write | mandatory |
| remoteAccessIdEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table remoteAccessIdEntryStatus = createRequest 2. Set remoteAccessId as required. The remoteAccessIdUserId and the remoteAccessIdPassword must be set before the entry becomes valid. To set the remoteAccessIdsEntryPermgroups or remoteAccessIdsEntryMaxSessions before the entry is valid, set these fields before both the password and userId are set. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.20 | EntryStatus | read-write | mandatory |
| remoteAccessIdEntryIPMIProvisioned OBJECT-TYPE Indicates if the user has been provisioned as an IPMI account. If this is user is provisioned as an IPMI account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for IPMI provisioning, setting the value to yes will return an error. When provisioning an IPMI account by setting this object to yes(1), the SNMPv3 account is also automatically provisioned. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.21 | INTEGER {no(0), yes(1)} | read-write | mandatory |
| remoteAccessIdEntrySNMPv3Provisioned OBJECT-TYPE Indicates if the user has been provisioned as an SNMPv3 account. If this is user is provisioned as an SNMPv3 account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for SNMPv3 provisioning, setting the value to yes will return an error. When provisioning a SNMPv3 account by setting this object to yes(1), the IPMI account is also automatically provisioned. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.22 | INTEGER {no(0), yes(1)} | read-write | mandatory |
| remoteAccessRBSroleTable OBJECT-TYPE Table of RBS User Role profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3 | not-accessible | mandatory | |
| remoteAccessRBSroleEntry OBJECT-TYPE User Role entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1 | not-accessible | mandatory | |
| roleIndex OBJECT-TYPE Index for RBS User Role entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1 | INTEGER (0..255) | read-only | mandatory |
| roleId OBJECT-TYPE Remote access RBS role entry null terminated string that contains the permission group ID. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| rbsSupervisor OBJECT-TYPE User has no restrictions. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsOperator OBJECT-TYPE User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisOperator OBJECT-TYPE User has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisAccountManagement OBJECT-TYPE User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisLogManagement OBJECT-TYPE User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisConfiguration OBJECT-TYPE User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisAdministration OBJECT-TYPE User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeOperator OBJECT-TYPE User has ability to browse status and properties of blades. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeRemotePresence OBJECT-TYPE User has ability to access the blades remote console. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeConfiguration OBJECT-TYPE User can modify and save any blade configuration parameter. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeAdministration OBJECT-TYPE User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleOperator OBJECT-TYPE User has ability to browse status and properties of I/O Modules, and to ping I/O Modules. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleConfiguration OBJECT-TYPE User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleAdministration OBJECT-TYPE User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table rbsEntryStatus = createRequest 2. Set roleId as required. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.23 | EntryStatus | read-write | mandatory |
| remoteAccessRBSscopeTable OBJECT-TYPE Table of RBS User Scope profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4 | not-accessible | mandatory | |
| remoteAccessRBSscopeEntry OBJECT-TYPE User Scope entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1 | not-accessible | mandatory | |
| scopeIndex OBJECT-TYPE Index for RBS User Scope Entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1 | INTEGER (0..255) | read-only | mandatory |
| scopeId OBJECT-TYPE Remote access RBS scope entry null terminated string that contains the permission group ID. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2 | OCTET STRING (SIZE(0..63)) | read-only | mandatory |
| rbsChassis OBJECT-TYPE User has access to the MM and chassis functions. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade1 OBJECT-TYPE User has access to the blade in slot 1. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade2 OBJECT-TYPE User has access to the blade in slot 2. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade3 OBJECT-TYPE User has access to the blade in slot 3. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade4 OBJECT-TYPE User has access to the blade in slot 4. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade5 OBJECT-TYPE User has access to the blade in slot 5. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade6 OBJECT-TYPE User has access to the blade in slot 6. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade7 OBJECT-TYPE User has access to the blade in slot 7. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade8 OBJECT-TYPE User has access to the blade in slot 8. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade9 OBJECT-TYPE User has access to the blade in slot 9. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade10 OBJECT-TYPE User has access to the blade in slot 10. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade11 OBJECT-TYPE User has access to the blade in slot 11. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade12 OBJECT-TYPE User has access to the blade in slot 12. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade13 OBJECT-TYPE User has access to the blade in slot 13. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade14 OBJECT-TYPE User has access to the blade in slot 14. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch1 OBJECT-TYPE User has access to I/O module 1. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch2 OBJECT-TYPE User has access to I/O module 2. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch3 OBJECT-TYPE User has access to I/O module 3. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch4 OBJECT-TYPE User has access to I/O module 4. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch5 OBJECT-TYPE User has access to I/O module 5. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch6 OBJECT-TYPE User has access to I/O module 6. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch7 OBJECT-TYPE User has access to I/O module 7. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch8 OBJECT-TYPE User has access to I/O module 8. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch9 OBJECT-TYPE User has access to I/O module 9. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch10 OBJECT-TYPE User has access to I/O module 10. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| cmmCentralManagerIPMISNMPv3 OBJECT-TYPE Indicates whether CMM is the central manager of the IPMI and SNMPv3 accounts. For a write, it can only be set to enabled. Once the CMM state is enabled, it can only be cleared by doing a reset to defaults. WARNING: Enabling CMM IPMI/SNMPv3 user account management will cause all presently existing IPMI/SNMPv3 user accounts on nodes to be overwritten. Please be sure to save any existing node IPMI/SNMPv3 account information before proceeding. | 1.3.6.1.4.1.2.3.51.2.4.1.4.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| userInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.5 | |||
| cli OBJECT-TYPE Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled. | 1.3.6.1.4.1.2.3.51.2.4.1.5.1 | INTEGER {disabled(0), telnet-only(1), ssh-only(2), enabled(3)} | read-write | mandatory |
| snmp OBJECT-TYPE Enable/Disable SNMP v1 and v3 access to the MM. The value enabled(3) means both telnet and ssh are enabled. | 1.3.6.1.4.1.2.3.51.2.4.1.5.2 | INTEGER {disabled(0), v1-only(1), v3-only(2), enabled(3)} | read-write | mandatory |
| tcm OBJECT-TYPE Enable/Disable TCP command mode (TCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. | 1.3.6.1.4.1.2.3.51.2.4.1.5.3 | INTEGER (0..20) | read-write | mandatory |
| web OBJECT-TYPE Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser. | 1.3.6.1.4.1.2.3.51.2.4.1.5.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| stcm OBJECT-TYPE Enable/Disable secure TCP command mode (STCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. | 1.3.6.1.4.1.2.3.51.2.4.1.5.5 | INTEGER (0..20) | read-write | mandatory |
| mmSshClientAuth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.6 | |||
| mmSshClientAuthPubKeyTable OBJECT-TYPE A table that contains client authentication public key information. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1 | not-accessible | mandatory | |
| mmSshClientAuthPubKeyEntry OBJECT-TYPE A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1 | not-accessible | mandatory | |
| mmSshClientAuthRemoteAccessIdIndex OBJECT-TYPE The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1 | INTEGER | read-only | mandatory |
| mmSshClientAuthPubKeyIndex OBJECT-TYPE The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2 | INTEGER | read-only | mandatory |
| mmSshClientAuthPubKeyType OBJECT-TYPE The type of the SSH public key represented by this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3 | INTEGER {sshDss(1), sshRsa(2)} | read-only | mandatory |
| mmSshClientAuthPubKeySize OBJECT-TYPE The size of the SSH public key represented by this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4 | INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)} | read-only | mandatory |
| mmSshClientAuthPubKeyFingerprint OBJECT-TYPE The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5 | OCTET STRING | read-only | mandatory |
| mmSshClientAuthPubKeyAcceptFrom OBJECT-TYPE This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the MM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyComment OBJECT-TYPE This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyAction OBJECT-TYPE import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the MM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the MM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8 | INTEGER {import(1), export(2)} | read-write | mandatory |
| mmSshClientAuthPubKeyEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it. Note: only one row may be created at one time. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9 | EntryStatus | read-write | mandatory |
| mmSshClientAuthPubKeyUserId OBJECT-TYPE The userid for the key entry. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.10 | OCTET STRING (SIZE(0..31)) | read-only | mandatory |
| mmSshClientAuthPubKeyUnused OBJECT-TYPE The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration. | 1.3.6.1.4.1.2.3.51.2.4.1.6.2 | INTEGER | read-only | mandatory |
| mmSshClientAuthPubKeyTftpServer OBJECT-TYPE IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). | 1.3.6.1.4.1.2.3.51.2.4.1.6.3 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyFileName OBJECT-TYPE File name on the TFTP server of an SSH client authentication public key. | 1.3.6.1.4.1.2.3.51.2.4.1.6.4 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyFileFormat OBJECT-TYPE File format of SSH client authentication public key files imported from or exported to the TFTP file server. | 1.3.6.1.4.1.2.3.51.2.4.1.6.5 | INTEGER {openSSH(1), rfc4716(2)} | read-write | mandatory |
| groupProfiles OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.7 | |||
| groupIdsTable OBJECT-TYPE Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1 | not-accessible | mandatory | |
| groupIdsEntry OBJECT-TYPE Group ID entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1 | not-accessible | mandatory | |
| groupIndex OBJECT-TYPE Index for Group IDs entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupId OBJECT-TYPE Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| groupRole OBJECT-TYPE Group Role. It indicates if the group has supervisor, operator, or custom access. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3 | OCTET STRING | read-only | mandatory |
| groupEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9 | EntryStatus | read-write | mandatory |
| groupRBSroleTable OBJECT-TYPE Table of Group Role profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2 | not-accessible | mandatory | |
| groupRBSroleEntry OBJECT-TYPE Group Role entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1 | not-accessible | mandatory | |
| groupRBSroleIndex OBJECT-TYPE Index for Group Role entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupRBSroleId OBJECT-TYPE Group ID | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| groupRBSSupervisor OBJECT-TYPE Group has no restrictions. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSOperator OBJECT-TYPE Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisOperator OBJECT-TYPE Group has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisAccountManagement OBJECT-TYPE Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisLogManagement OBJECT-TYPE Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisConfiguration OBJECT-TYPE Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisAdministration OBJECT-TYPE Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeOperator OBJECT-TYPE Group has ability to browse status and properties of blades. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeRemotePresence OBJECT-TYPE Group has ability to access the blade remote console The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeConfiguration OBJECT-TYPE Group can modify and save any blade configuration parameter. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeAdministration OBJECT-TYPE Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleOperator OBJECT-TYPE Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleConfiguration OBJECT-TYPE Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleAdministration OBJECT-TYPE Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSscopeTable OBJECT-TYPE Table of Group Scope profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3 | not-accessible | mandatory | |
| groupRBSscopeEntry OBJECT-TYPE Group Scope entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1 | not-accessible | mandatory | |
| groupRBSscopeIndex OBJECT-TYPE Index for Group Scope Entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupRBSscopeId OBJECT-TYPE Group ID | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| groupRBSChassis OBJECT-TYPE Group has access to the MM and chassis functions. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade1 OBJECT-TYPE Group has access to the blade in slot 1. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade2 OBJECT-TYPE Group has access to the blade in slot 2. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade3 OBJECT-TYPE Group has access to the blade in slot 3. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade4 OBJECT-TYPE Group has access to the blade in slot 4. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade5 OBJECT-TYPE Group has access to the blade in slot 5. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade6 OBJECT-TYPE Group has access to the blade in slot 6. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade7 OBJECT-TYPE Group has access to the blade in slot 7. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade8 OBJECT-TYPE Group has access to the blade in slot 8. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade9 OBJECT-TYPE Group has access to the blade in slot 9. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade10 OBJECT-TYPE Group has access to the blade in slot 10. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade11 OBJECT-TYPE Group has access to the blade in slot 11. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade12 OBJECT-TYPE Group has access to the blade in slot 12. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade13 OBJECT-TYPE Group has access to the blade in slot 13. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade14 OBJECT-TYPE Group has access to the blade in slot 14. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch1 OBJECT-TYPE Group has access to I/O module 1. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch2 OBJECT-TYPE Group has access to I/O module 2. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch3 OBJECT-TYPE Group has access to I/O module 3. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch4 OBJECT-TYPE Group has access to I/O module 4. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch5 OBJECT-TYPE Group has access to I/O module 5. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch6 OBJECT-TYPE Group has access to I/O module 6. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch7 OBJECT-TYPE Group has access to I/O module 7. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch8 OBJECT-TYPE Group has access to I/O module 8. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch9 OBJECT-TYPE Group has access to I/O module 9. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch10 OBJECT-TYPE Group has access to I/O module 10. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlerts OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2 | |||
| remoteAlertsCrit OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.1 | |||
| critPower OBJECT-TYPE Generate an alert if any of the system power supplies fail. | 1.3.6.1.4.1.2.3.51.2.4.2.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critBlade OBJECT-TYPE Generate an alert for any critical error condition on a blade. | 1.3.6.1.4.1.2.3.51.2.4.2.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critIO OBJECT-TYPE Generate an alert for any critical error condition on I/O module. | 1.3.6.1.4.1.2.3.51.2.4.2.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critStorage OBJECT-TYPE Generate an alert for any critical error condition on a Storage module. | 1.3.6.1.4.1.2.3.51.2.4.2.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critChassis OBJECT-TYPE Generate an alert for any critical error condition on chassis. | 1.3.6.1.4.1.2.3.51.2.4.2.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critFan OBJECT-TYPE Generate an alert for any critical error condition on cooling devices. | 1.3.6.1.4.1.2.3.51.2.4.2.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlertsNonCrit OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.2 | |||
| warnLogFull OBJECT-TYPE Generate an alert if the system log reaches 100% full. | 1.3.6.1.4.1.2.3.51.2.4.2.2.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnBlade OBJECT-TYPE Generate an alert for any warning condition on a blade. | 1.3.6.1.4.1.2.3.51.2.4.2.2.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnIO OBJECT-TYPE Generate an alert for any warning condition on I/O module. | 1.3.6.1.4.1.2.3.51.2.4.2.2.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnStorage OBJECT-TYPE Generate an alert for any warning condition on a Storage module. | 1.3.6.1.4.1.2.3.51.2.4.2.2.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnPower OBJECT-TYPE Generate an alert for any warning condition on power module. | 1.3.6.1.4.1.2.3.51.2.4.2.2.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnChassis OBJECT-TYPE Generate an alert for any warning condition on chassis. | 1.3.6.1.4.1.2.3.51.2.4.2.2.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnFan OBJECT-TYPE Generate an alert for any warning condition on cooling devices. | 1.3.6.1.4.1.2.3.51.2.4.2.2.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlertsSystem OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.3 | |||
| systemInventory OBJECT-TYPE Generate an alert if the a processor blade or media tray is added or removed. | 1.3.6.1.4.1.2.3.51.2.4.2.3.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemLog75PctFull OBJECT-TYPE Generate an alert if the system log reaches 75% full. | 1.3.6.1.4.1.2.3.51.2.4.2.3.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| networkChangeNotification OBJECT-TYPE Generate an alert if the MM has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module. | 1.3.6.1.4.1.2.3.51.2.4.2.3.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemRemoteLogin OBJECT-TYPE Generate an alert if the system detects a new user logged in from a remote site. | 1.3.6.1.4.1.2.3.51.2.4.2.3.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemBlade OBJECT-TYPE Generate an alert for any informational condition on a blade. | 1.3.6.1.4.1.2.3.51.2.4.2.3.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemIO OBJECT-TYPE Generate an alert for any informational condition on I/O module. | 1.3.6.1.4.1.2.3.51.2.4.2.3.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemStorage OBJECT-TYPE Generate an alert for any informational condition on a Storage module. | 1.3.6.1.4.1.2.3.51.2.4.2.3.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemPower OBJECT-TYPE Generate an alert for any informational condition on power module. | 1.3.6.1.4.1.2.3.51.2.4.2.3.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemChassis OBJECT-TYPE Generate an alert for any informational condition on chassis. | 1.3.6.1.4.1.2.3.51.2.4.2.3.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemFan OBJECT-TYPE Generate an alert for any informational condition on cooling device. | 1.3.6.1.4.1.2.3.51.2.4.2.3.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemPWRDO OBJECT-TYPE Generate an alert for any informational condition on power on and power off. | 1.3.6.1.4.1.2.3.51.2.4.2.3.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| securitySettings OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.3 | |||
| trespassWarning OBJECT-TYPE If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces. | 1.3.6.1.4.1.2.3.51.2.4.3.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| trespassWarningDefault OBJECT-TYPE Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.3.3 | INTEGER {execute(1)} | read-write | mandatory |
| trespassMessage OBJECT-TYPE The value of the trespass warning message. | 1.3.6.1.4.1.2.3.51.2.4.3.4 | OCTET STRING (SIZE(0..1600)) | read-write | mandatory |
| chassisSecuritySettings OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.3.5 | |||
| securityPolicySetting OBJECT-TYPE Determines chassis security policy. legacy mode(0) or secure mode(1). unknown(255) returned when policy can't be set or determined. | 1.3.6.1.4.1.2.3.51.2.4.3.5.1 | INTEGER {legacy(0), secure(1), unknown(255)} | read-write | mandatory |
| securityPolicyState OBJECT-TYPE Determines chassis security policy state. If pending(0), check securityPolicyStatusTable for details on actions needed, to make fully active. | 1.3.6.1.4.1.2.3.51.2.4.3.5.2 | INTEGER {active(0), pending(1), unknown(255)} | read-only | mandatory |
| securityPolicyStatusTable OBJECT-TYPE Table of pending security policy status. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3 | not-accessible | mandatory | |
| securityPolicyStatusEntry OBJECT-TYPE Pending security policy status entry | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1 | not-accessible | mandatory | |
| securityPolicyStatusIndex OBJECT-TYPE Pending Security policy status index. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.1 | INTEGER (0..128) | read-only | mandatory |
| securityPolicyStatusComponentType OBJECT-TYPE Indicates Component type and location with pending security status. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.2 | INTEGER {system(0), mgmtModule1(1), mgmtModule2(2), blade1(11), blade2(12), blade3(13), blade4(14), blade5(15), blade6(16), blade7(17), blade8(18), blade9(19), blade10(20), blade11(21), blade12(22), blade13(23), blade14(24), switchModule1(31), switchModule2(32), switchModule3(33), switchModule4(34)} | read-only | mandatory |
| securityPolicyStatusBayId OBJECT-TYPE Bay location of specific component. NOTE: securityPolicyStatusComponentType enumeration also indicates location. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.3 | INTEGER (0..14) | read-only | mandatory |
| securityPolicyStatusSummary OBJECT-TYPE Summary of pending security status for the component. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.4 | OCTET STRING | read-only | mandatory |
| securityPolicyStatusDetails OBJECT-TYPE Details of pending security status for the component. | 1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.5 | OCTET STRING | read-only | mandatory |
| cryptography OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.3.5.10 | |||
| cryptographySummary OBJECT-TYPE The current level and summary description of the cryptographic configuration. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.5 | OCTET STRING | read-only | mandatory |
| cryptographyMode OBJECT-TYPE The NIST cryptographic mode setting. A successful setting of this object initiates a reboot of the CMM within a few seconds. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.15 | INTEGER {nistCompatibility(0), nist800131a(1)} | read-write | mandatory |
| cryptographyModeDetailsTable OBJECT-TYPE A table of information indicating any NIST customization details and any reasons that the CMM cannot transition to the desired NIST mode. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18 | not-accessible | mandatory | |
| cryptographyModeDetailsEntry OBJECT-TYPE Cryptography mode status entry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1 | not-accessible | mandatory | |
| cryptographyModeDetailsIndex OBJECT-TYPE Cryptography mode details index. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.1 | INTEGER | read-only | mandatory |
| cryptographyModeDetailsType OBJECT-TYPE Indication of what type of message is reported for this entry. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.2 | INTEGER {customization(0), transition(1)} | read-only | mandatory |
| cryptographyModeDetailsDescription OBJECT-TYPE Message containing details for this cryptography entry. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.3 | OCTET STRING | read-only | mandatory |
| cryptographyModeComponentTable OBJECT-TYPE A table of information listing any IOMs or nodes that require a firmware update in order for the CMM to transition to the new mode. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20 | not-accessible | mandatory | |
| cryptographyModeComponentEntry OBJECT-TYPE Cryptography mode component entry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1 | not-accessible | mandatory | |
| cryptographyModeComponentIndex OBJECT-TYPE Cryptography mode component index. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.1 | INTEGER | read-only | mandatory |
| cryptographyModeComponentId OBJECT-TYPE A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.2 | OCTET STRING | read-only | mandatory |
| cryptographicCipher OBJECT-TYPE The cryptographic cipher suite setting. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.25 | INTEGER {legacy(0), tls12serveronly(1), tls12serverclient(2)} | read-write | mandatory |
| cryptographyCipherComponentTable OBJECT-TYPE A table of information listing any IOMs or nodes that are out of compliance with regards to the cipher suite setting and are therefore preventing the CMM from transitioning to the new cipher mode. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30 | not-accessible | mandatory | |
| cryptographyCipherComponentEntry OBJECT-TYPE Cryptography cipher component entry | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1 | not-accessible | mandatory | |
| cryptographyCipherComponentIndex OBJECT-TYPE Cryptography cipher component index. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.1 | INTEGER | read-only | mandatory |
| cryptographyCipherComponentId OBJECT-TYPE A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number. | 1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.2 | OCTET STRING | read-only | mandatory |
| cipherStrength OBJECT-TYPE Strength level of the NIST signing algorithm for certificate authority. None(0) indicates no signing algorithm has been set. When writing a new value to this object, a result of No Error is returned if the value is valid. However, the new algorithm will be used to create an authority certificate asynchronously. This process may take up to 1 minute to complete. So results for subsequent queries to the object's value may also be delayed while the new certificate is being generated. | 1.3.6.1.4.1.2.3.51.2.4.3.5.15 | INTEGER {none(0), rsa2048SHA1(1), rsa2048SHA256(2)} | read-write | mandatory |
| spClock OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.4 | |||
| spClockDateAndTimeSetting OBJECT-TYPE MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59 | 1.3.6.1.4.1.2.3.51.2.4.4.1 | OCTET STRING | read-write | mandatory |
| spClockTimezoneSetting OBJECT-TYPE MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. For write, the value must be a time zone listed in spClockTimezoneTable. The spClockTimezoneTable lists all valid time zones. Example: To set America's New York time zone, set the value to: 'America/New_York' For read, the value format is <offset>,<DST flag>,<time zone> (<comment>) Example: -4:00,yes,America/New_York (Eastern Time) | 1.3.6.1.4.1.2.3.51.2.4.4.2 | OCTET STRING | read-write | mandatory |
| spClockTimezoneTable OBJECT-TYPE Table of all time zones listed in zone.tab file | 1.3.6.1.4.1.2.3.51.2.4.4.3 | not-accessible | mandatory | |
| spClockTimezoneEntry OBJECT-TYPE Time zone entry | 1.3.6.1.4.1.2.3.51.2.4.4.3.1 | not-accessible | mandatory | |
| spClockTimezoneIndex OBJECT-TYPE Time zone table index. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.1 | INTEGER (0..1000) | read-only | mandatory |
| spClockTimezoneId OBJECT-TYPE Time zone instance id. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.2 | OCTET STRING | read-only | mandatory |
| spClockTimezoneCaption OBJECT-TYPE Time zone caption. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.3 | OCTET STRING | read-only | mandatory |
| spClockTimezoneDescription OBJECT-TYPE Time zone description. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.4 | OCTET STRING | read-only | mandatory |
| spClockTimezoneName OBJECT-TYPE Time zone name. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.5 | OCTET STRING | read-only | mandatory |
| spClockTimezoneStandardName OBJECT-TYPE Time zone standard name. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.6 | OCTET STRING | read-only | mandatory |
| spClockTimezoneStandardCaption OBJECT-TYPE Time zone standard caption. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.7 | OCTET STRING | read-only | mandatory |
| spClockTimezoneDaylightName OBJECT-TYPE Time zone daylight name. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.8 | OCTET STRING | read-only | mandatory |
| spClockTimezoneDaylightCaption OBJECT-TYPE Time zone daylight caption. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.9 | OCTET STRING | read-only | mandatory |
| spClockTimezoneCmmOffset OBJECT-TYPE CMM offset. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.10 | INTEGER | read-only | mandatory |
| spClockTimezoneStandardOffsetMinutes OBJECT-TYPE Standard GMT offset in minutes. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.11 | INTEGER | read-only | mandatory |
| spClockTimezoneStandardDaylightOffsetMinutes OBJECT-TYPE Standard GMT offset in minutes. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.12 | INTEGER | read-only | mandatory |
| spClockTimezoneDaylightDay OBJECT-TYPE There are two different interpretations for this field, depending on the value of DaylightDayOfWeek. In one case, DaylightDay defines the day-in-month on which daylight saving time starts. This interpretation is used when the DaylightDayOfWeek is 0. A positive or negative integer is specified to indicate whether the DaylightDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the DaylightMonth and -1 indicates the last day in the DaylightMonth. When DaylightDayOfWeek is not 0, DaylightDay is the day in the month on which daylight saving time starts, as defined in conjunction with DaylightDayOfWeek. For example, if DaylightDay is 15 and DaylightDayOfWeek is Saturday, then daylight saving time starts on the first Saturday on or after the 15th day in the DaylightMonth (that is, the third Saturday in the month). If DaylightDay is 20 and DaylightDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20th day in the DaylightMonth. If DaylightDay is -1 and DaylightDayOfWeek is -Sunday, then this indicates the last Sunday in the month. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.13 | INTEGER {undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightDayOfWeek OBJECT-TYPE Day of week daylight saving begins. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.14 | INTEGER {minusSaturday(-7), minusFriday(-6), minusThursday(-5), minusWednesday(-4), minusTuesday(-3), minusMonday(-2), minusSunday(-1), exactDayOfMonth(0), sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightMonth OBJECT-TYPE Month daylight saving begins. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.15 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11), undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightStandardDay OBJECT-TYPE There are two different interpretations for this property, depending on the value of StandardDayOfWeek. In one case, StandardDay defines the day-in-month on which daylight saving time ends. This interpretation is used when the StandardDayOfWeek is 0. A positive or negative integer is specified to indicate whether the StandardDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the StandardMonth and -1 indicates the last day in the StandardMonth. When StandardDayOfWeek is not 0, StandardDay is the day-in-month on which daylight saving time ends, as defined in conjunction with StandardDayOfWeek. For example, if StandardDay is 15 and StandardDayOfWeek is Saturday, then daylight saving time ends on the first Saturday on or after the 15th day in the StandardMonth (that is, the third Saturday in the month). If StandardDay is 20 and StandardDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20 th day in the StandardMonth. If StandardDay is -1 and StandardDayOfWeek is -Sunday, then this indicates the last Sunday in the StandardMonth. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.16 | INTEGER {undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightStandardDayOfWeek OBJECT-TYPE Day of week daylight saving ends. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.17 | INTEGER {minusSaturday(-7), minusFriday(-6), minusThursday(-5), minusWednesday(-4), minusTuesday(-3), minusMonday(-2), minusSunday(-1), exactDayOfMonth(0), sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightStandardMonth OBJECT-TYPE Month daylight saving ends. | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.18 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11), undefined(255)} | read-only | mandatory |
| spClockTimezoneDaylightIntervalInMinutes OBJECT-TYPE Interval in minutes (Daylight saving begins). | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.19 | INTEGER | read-only | mandatory |
| spClockTimezoneDaylightStandardInMinutes OBJECT-TYPE Interval in minutes (Daylight saving ends). | 1.3.6.1.4.1.2.3.51.2.4.4.3.1.20 | INTEGER | read-only | mandatory |
| spClockTimezoneDaylightStart OBJECT-TYPE DST start. | 1.3.6.1.4.1.2.3.51.2.4.4.5 | OCTET STRING | read-only | mandatory |
| spClockTimezoneDaylightEnd OBJECT-TYPE DST end. | 1.3.6.1.4.1.2.3.51.2.4.4.6 | OCTET STRING | read-only | mandatory |
| spIdentification OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.5 | |||
| spTxtId OBJECT-TYPE Text description of the MM. NOTE: Do not put any 'space characters' at end of the string. | 1.3.6.1.4.1.2.3.51.2.4.5.1 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| networkConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9 | |||
| networkInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1 | |||
| extEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.1 | |||
| extEthernetInterfaceType OBJECT-TYPE The type of interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| extEthernetInterfaceHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| extEthernetInterfaceIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.4 | IpAddress | read-write | mandatory |
| extEthernetInterfaceDataRate OBJECT-TYPE Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.5 | INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1Gigabit(6)} | read-write | mandatory |
| extEthernetInterfaceDuplexSetting OBJECT-TYPE Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.6 | INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)} | read-write | mandatory |
| extEthernetInterfaceLAA OBJECT-TYPE Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.7 | OCTET STRING (SIZE(17)) | read-write | mandatory |
| extEthernetInterfaceDhcpEnabled OBJECT-TYPE Disable or enable DHCP on this interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.8 | INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)} | read-write | mandatory |
| extEthernetInterfaceGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.9 | IpAddress | read-write | mandatory |
| extEthernetInterfaceBIA OBJECT-TYPE Specifies the burned-in MAC (BIA) address. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.10 | OCTET STRING (SIZE(17)) | read-only | mandatory |
| extEthernetInterfaceMTU OBJECT-TYPE Contains the Maximum Transmission Unit(MTU) for the ethernet interface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.13 | INTEGER | read-write | mandatory |
| extEthernetInterfaceSubnetMask OBJECT-TYPE Contains the subnet mask for the ethernet interface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.14 | IpAddress | read-write | mandatory |
| dhcpEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16 | |||
| dhcpHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| dhcpIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2 | IpAddress | read-only | mandatory |
| dhcpGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3 | IpAddress | read-only | mandatory |
| dhcpSubnetMask OBJECT-TYPE Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4 | IpAddress | read-only | mandatory |
| dhcpDomainName OBJECT-TYPE Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| dhcpDHCPServer OBJECT-TYPE Contains the DHCP server IP address used to acquire the DHCP settings. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6 | IpAddress | read-only | mandatory |
| dhcpPrimaryDNSServer OBJECT-TYPE Contains the Primary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7 | IpAddress | read-only | mandatory |
| dhcpSecondaryDNSServer OBJECT-TYPE Contains the Secondary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8 | IpAddress | read-only | mandatory |
| dhcpTertiaryDNSServer OBJECT-TYPE Contains the tertiary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9 | IpAddress | read-only | mandatory |
| extEthernetInterfaceFloatingIPAddress OBJECT-TYPE Contains the floating IP address for the external ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.22 | IpAddress | read-write | mandatory |
| standbyExtEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.3 | |||
| standbyExtEthernetInterfaceType OBJECT-TYPE The type of interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| standbyExtEthernetInterfaceHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| standbyExtEthernetInterfaceIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.4 | IpAddress | read-write | mandatory |
| standbyExtEthernetInterfaceDataRate OBJECT-TYPE Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.5 | INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1Gigabit(6)} | read-write | mandatory |
| standbyExtEthernetInterfaceDuplexSetting OBJECT-TYPE Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.6 | INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)} | read-write | mandatory |
| standbyExtEthernetInterfaceLAA OBJECT-TYPE Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.7 | OCTET STRING (SIZE(17)) | read-write | mandatory |
| standbyExtEthernetInterfaceDhcpEnabled OBJECT-TYPE Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.8 | INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)} | read-write | mandatory |
| standbyExtEthernetInterfaceGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.9 | IpAddress | read-write | mandatory |
| standbyExtEthernetInterfaceBIA OBJECT-TYPE Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.10 | OCTET STRING (SIZE(17)) | read-only | mandatory |
| standbyExtEthernetInterfaceMTU OBJECT-TYPE Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.13 | INTEGER | read-write | mandatory |
| standbyExtEthernetInterfaceSubnetMask OBJECT-TYPE Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.14 | IpAddress | read-write | mandatory |
| advancedFailover OBJECT-TYPE User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, do not swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.15 | INTEGER {off(0), ipnoswap(1), ipswap(2)} | read-write | mandatory |
| standbyDhcpEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16 | |||
| standbyDhcpHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyDhcpIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2 | IpAddress | read-only | mandatory |
| standbyDhcpGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3 | IpAddress | read-only | mandatory |
| standbyDhcpSubnetMask OBJECT-TYPE Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4 | IpAddress | read-only | mandatory |
| standbyDhcpDomainName OBJECT-TYPE Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyDhcpDHCPServer OBJECT-TYPE Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6 | IpAddress | read-only | mandatory |
| standbyDhcpPrimaryDNSServer OBJECT-TYPE Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7 | IpAddress | read-only | mandatory |
| standbyDhcpSecondaryDNSServer OBJECT-TYPE Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8 | IpAddress | read-only | mandatory |
| standbyDhcpTertiaryDNSServer OBJECT-TYPE Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9 | IpAddress | read-only | mandatory |
| extEthernetInterfaceIPv6 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4 | |||
| extEthernetInterfaceIPv6Type OBJECT-TYPE The type of interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| extEthernetInterfaceIPv6Enabled OBJECT-TYPE The current IPv6 enabled or disabled state of this MM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.2 | INTEGER {enabled(1)} | read-write | mandatory |
| extEthernetInterfaceIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5 | |||
| extEthernetInterfaceIPv6LocalAddress OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1 | |||
| extEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceIPv6StaticIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2 | |||
| extEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE The IPv6 static IP address enabled or disabled state for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2 | InetAddressIPv6 | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3 | INTEGER (1..128) | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4 | InetAddressIPv6 | read-write | mandatory |
| extEthernetInterfaceIPv6LinkFloatingAddress OBJECT-TYPE The IPv6 floating IP address for the external ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.5 | InetAddressIPv6 | read-write | mandatory |
| extEthernetInterfaceIPv6AutoIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3 | |||
| extEthernetInterfaceIPv6AutoIPConfigEnabled OBJECT-TYPE The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceDHCPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2 | |||
| extEthernetInterfaceDHCPv6Enabled OBJECT-TYPE The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6DomainName OBJECT-TYPE The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| extEthernetInterfaceDHCPv6PrimaryDNSServer OBJECT-TYPE The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6SecondaryDNSServer OBJECT-TYPE The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6TertiaryDNSServer OBJECT-TYPE The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6Server OBJECT-TYPE The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceIPv6StatelessAutoConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3 | |||
| extEthernetInterfaceIPv6StatelessAutoConfigEnabled OBJECT-TYPE The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE Table of stateless Auto-Config addresses entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2 | not-accessible | mandatory | |
| extEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE Stateless Auto-Config address entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1 | not-accessible | mandatory | |
| extEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1 | INTEGER | read-only | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3 | INTEGER (1..128) | read-only | mandatory |
| standbyExtEthernetInterfaceIPv6 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5 | |||
| standbyEthernetInterfaceIPv6LocalAddress OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1 | |||
| standbyEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE The IPv6 link local IP address for the standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2 | |||
| standbyEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE The IPv6 static IP address state for the MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE The IPv6 static IP address for the standby MM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2 | InetAddressIPv6 | read-write | mandatory |
| standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE The IPv6 static IP address prefix length for the standyby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3 | INTEGER (1..128) | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE The IPv6 static IP address default route for the standby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3 | |||
| standbyEthernetInterfaceDHCPv6Enabled OBJECT-TYPE The DHCPv6 enabled or disabled state for the standby MM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE The IPv6 address for the standby MM assigned by DHCPv6 server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6DomainName OBJECT-TYPE The 64 byte Domain Name for the standby MM assigned by the DHCPv6 server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4 | not-accessible | mandatory | |
| standbyEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE Stateless Auto-Config address entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1 | not-accessible | mandatory | |
| standbyEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE Index for stateless Auto-Config addresses. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1 | INTEGER | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE The stateless Auto-Configuration IPv6 address. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE The stateless Auto-Configration address prefix length. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3 | INTEGER (1..128) | read-only | mandatory |
| ddnsStatus OBJECT-TYPE Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration. | 1.3.6.1.4.1.2.3.51.2.4.9.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| hostName OBJECT-TYPE Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.11 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| standbyHostName OBJECT-TYPE Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.12 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| domainName OBJECT-TYPE The user assigned DNS domain name. | 1.3.6.1.4.1.2.3.51.2.4.9.1.13 | OCTET STRING | read-write | mandatory |
| standbyDomainName OBJECT-TYPE The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.14 | OCTET STRING | read-write | mandatory |
| activateNetworkUpdates OBJECT-TYPE When read, the return value indicates if there are any pending network updates ready to be applied. Writing any value will apply any pending network updates immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.1.16 | INTEGER {noPendingUpdates(0), pendingUpdates(1)} | read-write | mandatory |
| vlanConfigure OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.20 | |||
| vlanGlobalState OBJECT-TYPE This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the vlanCMMTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.1 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanCommitTimeout OBJECT-TYPE This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.2 | INTEGER (1..255) | read-write | mandatory |
| vlanCommitState OBJECT-TYPE This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.3 | INTEGER {noChangesPending(1), commitNeeded(2), executeCommit(3)} | read-write | mandatory |
| vlanCMMTable OBJECT-TYPE This table contains the VLAN configuration objects. The default entry has an vlanCMMIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanCMMEntryStatus, at vlanCMMIndex=2 to the value of createRequest(2) and also setting the object, vlanCMMVlanId, at vlanCMMIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20 | not-accessible | mandatory | |
| vlanCMMEntry OBJECT-TYPE VLAN entries. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1 | not-accessible | mandatory | |
| vlanCMMIndex OBJECT-TYPE Index for VLAN entry. If vlanCMMIndex is equal to 1, it is the Default VLAN entry and cannot be deleted. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1 | INTEGER (1..2) | read-only | mandatory |
| vlanCMMVlanId OBJECT-TYPE Valid VLAN ID. Allowed values are 5..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanCMMIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanCMMState set to enable(1) or restart(2) for this change to take effect. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2 | INTEGER (1..4094) | read-write | mandatory |
| vlanCMMName OBJECT-TYPE This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| vlanCMMEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanCMMEntryStatus = createRequest 2. Set vlanCMMVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanCMMEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) cannot be deleted. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4 | EntryStatus | read-write | mandatory |
| vlanCMMState OBJECT-TYPE This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5 | INTEGER {disable(0), enable(1), restart(2)} | read-write | mandatory |
| vlanCMMSOLAccess OBJECT-TYPE This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanCMMTagging OBJECT-TYPE This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanCMMIndex value of 1. By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanCMMIPv4Address OBJECT-TYPE This object sets the IPv4 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31 | IpAddress | read-write | mandatory |
| vlanCMMIPv4Gateway OBJECT-TYPE This object sets the IPv4 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32 | IpAddress | read-write | mandatory |
| vlanCMMIPv4Mask OBJECT-TYPE This object sets the IPv4 subnet mask for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRoute1 OBJECT-TYPE This object sets the IPv4 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRouteMask1 OBJECT-TYPE This object sets the IPv4 subnet route mask 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRoute2 OBJECT-TYPE This object sets the IPv4 address of the subnet route 2 for VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRouteMask2 OBJECT-TYPE This object sets the IPv4 subnet route mask 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRoute3 OBJECT-TYPE This object sets the IPv4 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55 | IpAddress | read-write | mandatory |
| vlanCMMIPv4SubnetRouteMask3 OBJECT-TYPE This object sets the IPv4 subnet route mask 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56 | IpAddress | read-write | mandatory |
| vlanCMMIPv6Address OBJECT-TYPE This object sets the IPv6 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.71 | InetAddressIPv6 | read-write | mandatory |
| vlanCMMIPv6AddressPrefixLen OBJECT-TYPE This object sets the IPv6 address prefix length for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.72 | INTEGER (0..128) | read-write | mandatory |
| vlanCMMIPv6Gateway OBJECT-TYPE This object sets the IPv6 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.73 | InetAddressIPv6 | read-write | mandatory |
| vlanCMMIPv6SubnetRoute1 OBJECT-TYPE This object sets the IPv6 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.91 | InetAddressIPv6 | read-write | mandatory |
| vlanCMMIPv6SubnetRoutePrefixLen1 OBJECT-TYPE This object sets the IPv6 address prefix length of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.92 | INTEGER (0..128) | read-write | mandatory |
| vlanCMMIPv6SubnetRoute2 OBJECT-TYPE This object sets the IPv6 address of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.93 | InetAddressIPv6 | read-write | mandatory |
| vlanCMMIPv6SubnetRoutePrefixLen2 OBJECT-TYPE This object sets the IPv6 address prefix length of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.94 | INTEGER (0..128) | read-write | mandatory |
| vlanCMMIPv6SubnetRoute3 OBJECT-TYPE This object sets the IPv6 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.95 | InetAddressIPv6 | read-write | mandatory |
| vlanCMMIPv6SubnetRoutePrefixLen3 OBJECT-TYPE This object sets the IPv6 address prefix length of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.96 | INTEGER (0..128) | read-write | mandatory |
| vlanCMMTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, vlanCMMTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.21 | INTEGER | read-only | mandatory |
| tcpProtocols OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3 | |||
| snmpAgentConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1 | |||
| snmpSystemContact OBJECT-TYPE A NULL terminated 48 byte string that contains the SNMP agent contact name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.1 | OCTET STRING (SIZE(0..48)) | read-write | mandatory |
| snmpSystemLocation OBJECT-TYPE A NULL terminated 48 byte string that contains the SNMP agent location name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.2 | OCTET STRING (SIZE(0..48)) | read-write | mandatory |
| snmpSystemAgentTrapsDisable OBJECT-TYPE Disable or enable SNMP traps. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.3 | INTEGER {trapsEnabled(0), trapsDisabled(1)} | read-write | mandatory |
| snmpAgentCommunityConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4 | |||
| snmpCommunityTable OBJECT-TYPE Table of SNMP Community entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1 | not-accessible | mandatory | |
| snmpCommunityEntry OBJECT-TYPE SNMP community entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1 | not-accessible | mandatory | |
| snmpCommunityEntryIndex OBJECT-TYPE Index for SNMP Agent Community entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| snmpCommunityEntryCommunityName OBJECT-TYPE SNMP Community entry name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress1 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress2 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress3 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityViewType OBJECT-TYPE Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6 | INTEGER {read-Traps(1), write-Read-Traps(2), traps-Only(3)} | read-write | mandatory |
| snmpv1SystemAgentEnable OBJECT-TYPE Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| snmpv3SystemAgentEnable OBJECT-TYPE Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| snmpAgentUserProfileConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9 | |||
| snmpUserProfileTable OBJECT-TYPE Table of SNMPv3 User Profile entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1 | not-accessible | mandatory | |
| snmpUserProfileEntry OBJECT-TYPE SNMP User Profile entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1 | not-accessible | mandatory | |
| snmpUserProfileEntryIndex OBJECT-TYPE Index for SNMPv3 Agent User Profile entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| snmpUserProfileEntryContextName OBJECT-TYPE SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| snmpUserProfileEntryAuthProt OBJECT-TYPE SNMPv3 User Profile entry - Authentication Protocol supported by the user. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4 | INTEGER {md5(2), sha(3)} | read-write | mandatory |
| snmpUserProfileEntryPrivProt OBJECT-TYPE SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6 | INTEGER {none(1), des(2), aes(4)} | read-write | mandatory |
| snmpUserProfileEntryPrivPassword OBJECT-TYPE SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| snmpUserProfileEntryViewType OBJECT-TYPE SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8 | INTEGER {read-Traps(1), read-Write-Traps(2), traps-Only(3)} | read-write | mandatory |
| snmpUserProfileEntryIpAddress OBJECT-TYPE SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpUserProfileEntryUserId OBJECT-TYPE The userid for the SNMPv3 Agent User Profile entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.10 | OCTET STRING (SIZE(0..31)) | read-only | mandatory |
| dnsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.2 | |||
| dnsEnabled OBJECT-TYPE Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.1 | INTEGER {dnsDisabled(0), dnsEnabled(1)} | read-write | mandatory |
| dnsServerIPAddress1 OBJECT-TYPE Contains the primary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.2 | IpAddress | read-write | mandatory |
| dnsServerIPAddress2 OBJECT-TYPE Contains the secondary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.3 | IpAddress | read-write | mandatory |
| dnsServerIPAddress3 OBJECT-TYPE Contains the tertiary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.4 | IpAddress | read-write | mandatory |
| dnsServerIPv6Address1 OBJECT-TYPE Contains the primary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.12 | InetAddressIPv6 | read-write | mandatory |
| dnsServerIPv6Address2 OBJECT-TYPE Contains the secondary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.13 | InetAddressIPv6 | read-write | mandatory |
| dnsServerIPv6Address3 OBJECT-TYPE Contains the tertiary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.14 | InetAddressIPv6 | read-write | mandatory |
| dnsPriority OBJECT-TYPE Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.20 | INTEGER {ipv6(1), ipv4(2)} | read-write | mandatory |
| smtpConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.3 | |||
| smtpServerNameOrIPAddress OBJECT-TYPE A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.1 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| attachmentsToEmailAlerts OBJECT-TYPE Indicates if the service information should be attached to an email alert. | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.2 | INTEGER {noAttachments(0), attachServiceInformation(1)} | read-write | mandatory |
| smtpEmailDomain OBJECT-TYPE A NULL terminated string that contains the SMTP email domain. If this field is empty, the MM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| tcpApplicationConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.4 | |||
| telnetInactivityTimeout OBJECT-TYPE Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.1 | INTEGER | read-write | mandatory |
| commandModeInactivityTimeout OBJECT-TYPE The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.2 | INTEGER | read-write | mandatory |
| secureCommandModeEnable OBJECT-TYPE Set Secure TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.3 | INTEGER | read-write | mandatory |
| commandModeEnable OBJECT-TYPE Set TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.4 | INTEGER | read-write | mandatory |
| slpAddrType OBJECT-TYPE Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.5 | INTEGER {multicast(0), broadcast(1)} | read-write | mandatory |
| slpEnable OBJECT-TYPE Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| telnetEnable OBJECT-TYPE Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sshEnable OBJECT-TYPE Disable/Enable SSH. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sslServerEnable OBJECT-TYPE Disable/Enable SSL Server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sslClientEnable OBJECT-TYPE Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ftpEnable OBJECT-TYPE Disable/Enable FTP. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sftpEnable OBJECT-TYPE Disable/Enable SFTP. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| tftpEnable OBJECT-TYPE Disable/Enable TFTP. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ftpTimeout OBJECT-TYPE The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.23 | INTEGER | read-write | mandatory |
| mmSshServerConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27 | |||
| mmSshServerHostKeyTable OBJECT-TYPE A table that contains per public/private host key pair information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1 | not-accessible | mandatory | |
| mmSshServerHostKeyEntry OBJECT-TYPE A list of information about a particular public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1 | not-accessible | mandatory | |
| mmSshServerHostKeyIndex OBJECT-TYPE The index of the public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1 | INTEGER | read-only | mandatory |
| mmSshServerHostKeyType OBJECT-TYPE The type of the public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2 | INTEGER {sshDss(1), sshRsa(2)} | read-only | mandatory |
| mmSshServerHostKeySize OBJECT-TYPE The size of the public/private host key pair. NOTE: The MM supports only the bits2048 value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3 | INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)} | read-only | mandatory |
| mmSshServerHostKeyFingerprint OBJECT-TYPE The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4 | OCTET STRING | read-only | mandatory |
| mmSshServerHostKeyGenerate OBJECT-TYPE Initiate the new Host Keys generation process for the MM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2 | INTEGER {execute(1)} | read-write | mandatory |
| mmSshServerHostKeyGenerateProgress OBJECT-TYPE Indicate the progress of the key generation process. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3 | OCTET STRING | read-only | mandatory |
| cimEnable OBJECT-TYPE Disable/Enable CIM (Common Information Model) interface. NOTE: Change to CIM enable/disable will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.50 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| tcpPortAssignmentCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.5 | |||
| tcpPortsRestoreDefault OBJECT-TYPE Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 FTP: 21 FTP Data: 20 TFTP: 69 SLP: 427 CIM: 5989 NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.1 | INTEGER {execute(1)} | read-write | mandatory |
| httpPortAssignment OBJECT-TYPE HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.2 | INTEGER | read-write | mandatory |
| httpsPortAssignment OBJECT-TYPE SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.3 | INTEGER | read-write | mandatory |
| telnetPortAssignment OBJECT-TYPE Telnet port number. Default value is 23. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.4 | INTEGER | read-write | mandatory |
| sshPortAssignment OBJECT-TYPE SSH port number. Default value is 22. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.5 | INTEGER | read-write | mandatory |
| snmpAgentPortAssignment OBJECT-TYPE SNMP Agent port number. Default value is 161. Changes take effect after several seconds. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.6 | INTEGER | read-write | mandatory |
| snmpTrapsPortAssignment OBJECT-TYPE SNMP Traps port number. Default value is 162. Changes take effect after several seconds. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.7 | INTEGER | read-write | mandatory |
| commandModePortAssignment OBJECT-TYPE TCP Command Mode port number. Default value is 6090. Change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.8 | INTEGER | read-write | mandatory |
| secureCommandModePortAssignment OBJECT-TYPE Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.9 | INTEGER | read-write | mandatory |
| ftpPortAssignment OBJECT-TYPE FTP port number. Default value is 21. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.13 | INTEGER | read-write | mandatory |
| ftpDataPortAssignment OBJECT-TYPE FTP Data port number. Default value is 20. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.14 | INTEGER | read-write | mandatory |
| tftpPortAssignment OBJECT-TYPE TFTP port number. Default value is 69. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.15 | INTEGER | read-write | mandatory |
| slpPortAssignment OBJECT-TYPE Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.19 | INTEGER | read-write | mandatory |
| cimPortAssignment OBJECT-TYPE CIM (Common Information Model) port number. Default value is 5989. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.50 | INTEGER | read-write | mandatory |
| ldapClientCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.6 | |||
| ldapServer1NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.1 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer1PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.2 | INTEGER | read-write | mandatory |
| ldapServer2NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.3 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer2PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.4 | INTEGER | read-write | mandatory |
| ldapServer3NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.5 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer3PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.6 | INTEGER | read-write | mandatory |
| ldapRootDN OBJECT-TYPE A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.7 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapGroupFilter OBJECT-TYPE This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.9 | OCTET STRING (SIZE(0..511)) | read-write | mandatory |
| ldapBindingMethod OBJECT-TYPE On initial binds to the LDAP server during user authentication, there are two options: Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.10 | INTEGER {clientAuthentication(1), userPrincipalName(2)} | read-write | mandatory |
| ldapClientAuthenticationDN OBJECT-TYPE The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. These parameters are configured here. Note that the password can be left blank. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.11 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapClientAuthenticationPassword OBJECT-TYPE The client authentication password | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.12 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| ldapUIDsearchAttribute OBJECT-TYPE When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.13 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapGroupSearchAttribute OBJECT-TYPE When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.14 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapLoginPermissionAttribute OBJECT-TYPE When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.15 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapUseDNSOrPreConfiguredServers OBJECT-TYPE The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.16 | INTEGER {usePreConfiguredLDAPServers(0), useDNSToFindLDAPServers(1)} | read-write | mandatory |
| ldapRBSModelCfg OBJECT-TYPE There are two mechanisms to authenticate and authorize users on the MM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and MMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. MM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.20 | INTEGER {oldPermissionString(0), newRBSModel(1)} | read-write | mandatory |
| ldapTargetName OBJECT-TYPE When administrator chooses Enhanced Role Based Security authentication model, he can associate one MM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The MM target name can be looked as alias of MM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character) | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.21 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| ldapAuthCfg OBJECT-TYPE If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.22 | INTEGER {authenticationAndAuthorization(0), authenticationOnly(1)} | read-write | mandatory |
| ldapForestName OBJECT-TYPE LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.23 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapDomainName OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP Domain Name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.24 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer4NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.25 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer4PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.26 | INTEGER | read-write | mandatory |
| uplinkCheckConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.7 | |||
| uplinkCheckEnabled OBJECT-TYPE Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.1 | INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)} | read-write | mandatory |
| uplinkCheckDelay OBJECT-TYPE Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.2 | INTEGER | read-write | mandatory |
| logicalUplinkDestination OBJECT-TYPE Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.3 | IpAddress | read-write | mandatory |
| logicalUplinkCheckEnabled OBJECT-TYPE Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.4 | INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)} | read-write | mandatory |
| logicalUplinkCheckDelay OBJECT-TYPE Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.5 | INTEGER | read-write | mandatory |
| physicalUplinkCheckDelayInSecs OBJECT-TYPE Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.6 | INTEGER | read-write | mandatory |
| logicalUplinkCheckDelayInSecs OBJECT-TYPE Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.7 | INTEGER | read-write | mandatory |
| logicalUplinkIPv6Destination OBJECT-TYPE Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.8 | InetAddressIPv6 | read-write | mandatory |
| logicalUplinkFailoverPolicy OBJECT-TYPE Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.9 | INTEGER {either(1), both(2)} | read-write | mandatory |
| ntpConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.8 | |||
| ntpEnable OBJECT-TYPE Disable/Enable the NTP client. The client will update the MM system clock at the frequency specified. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ntpIpAddressHostname OBJECT-TYPE NTP server's IP address or hostname if DNS is enabled and configured. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| ntpUpdateFrequency OBJECT-TYPE The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the MM clock can only be synchronized with the NTP server manually. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.3 | INTEGER | read-write | mandatory |
| ntpLastUpdate OBJECT-TYPE The date and time that the NTP server last updated the system clock. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.4 | OCTET STRING | read-only | mandatory |
| ntpUpdateClock OBJECT-TYPE Update the MM system clock with the specified NTP server. A valid NTP server must be configured first. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.5 | INTEGER {execute(1)} | read-write | mandatory |
| ntpAuthEntry OBJECT-TYPE The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key index> must be an integer between 1 and 65535. <key type> must be M. <key> is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: <key index> <key type> It does not return the actual key. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.6 | OCTET STRING | read-write | mandatory |
| ntpAuthEnable OBJECT-TYPE Enables/Disables NTP v3 authentication | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| syslogConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.9 | |||
| syslogSevFilterLevel OBJECT-TYPE syslogSevFilterLevel error/warning/information . | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.1 | INTEGER {error(0), warning(1), information(2)} | read-write | mandatory |
| syslogCollectorConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2 | |||
| syslogCollectorTable OBJECT-TYPE Table of Syslog Collector entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1 | not-accessible | mandatory | |
| syslogCollectorEntry OBJECT-TYPE Syslog Collector entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1 | not-accessible | mandatory | |
| syslogCollectorIndex OBJECT-TYPE Index for Syslog Collector entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| syslogCollectorHostnameOrIpAddress OBJECT-TYPE Syslog Collector IP address or host name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| syslogCollectorPort OBJECT-TYPE Syslog Collector port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3 | INTEGER (1..65535) | read-write | mandatory |
| syslogCollectorEnable OBJECT-TYPE Syslog Collector enable/disable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| syslogTestPacket OBJECT-TYPE Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.3 | INTEGER {execute(1)} | read-write | mandatory |
| solConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10 | |||
| solGlobalConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10.1 | |||
| solEnable OBJECT-TYPE Disable/Enable SOL dynamically. | 1.3.6.1.4.1.2.3.51.2.4.10.1.1 | INTEGER {solDisabled(0), solEnabled(1)} | read-write | mandatory |
| solAccumulateTimeout OBJECT-TYPE This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms. | 1.3.6.1.4.1.2.3.51.2.4.10.1.3 | INTEGER | read-write | mandatory |
| solCharSendThreshold OBJECT-TYPE This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 251 | 1.3.6.1.4.1.2.3.51.2.4.10.1.4 | INTEGER | read-write | mandatory |
| solRetry OBJECT-TYPE Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired. | 1.3.6.1.4.1.2.3.51.2.4.10.1.5 | INTEGER | read-write | mandatory |
| solRetryInterval OBJECT-TYPE Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back. | 1.3.6.1.4.1.2.3.51.2.4.10.1.6 | INTEGER | read-write | mandatory |
| solExitToCliKeySeq OBJECT-TYPE This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (. | 1.3.6.1.4.1.2.3.51.2.4.10.1.7 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| solResetBladeKeySeq OBJECT-TYPE This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R. | 1.3.6.1.4.1.2.3.51.2.4.10.1.8 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| solBladeConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10.2 | |||
| solBladeTable OBJECT-TYPE SOL Blade configuration table. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1 | not-accessible | mandatory | |
| solBladeEntry OBJECT-TYPE SOL Blade table entry | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1 | not-accessible | mandatory | |
| solBladeIndex OBJECT-TYPE SOL Blade table index. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1 | INTEGER | read-only | mandatory |
| solBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2 | OCTET STRING | read-only | mandatory |
| solBladeEnable OBJECT-TYPE Disable or enable a SOL on a blade. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3 | INTEGER {solBladeDisabled(0), solBladeEnabled(1)} | read-write | mandatory |
| solBladeIpAddr OBJECT-TYPE This is deprecated in favor of solBladeIpAddr6. IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4 | IpAddress | read-only | deprecated |
| solBladeSessionStatus OBJECT-TYPE Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5 | INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)} | read-only | mandatory |
| solBladeCapability OBJECT-TYPE Display whether or not the blade support SOL feature. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6 | INTEGER {notSupport(0), support(1)} | read-only | mandatory |
| solBladeIpAddr6 OBJECT-TYPE IPv6 address of the blade. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.7 | InetAddressIPv6 | read-only | mandatory |
| solBladeRetryInterval OBJECT-TYPE Retry interval time in miliseconds. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.8 | INTEGER | read-only | mandatory |
| solBladeRetryCount OBJECT-TYPE Retry count. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.9 | INTEGER | read-only | mandatory |
| solBladeBytesSent OBJECT-TYPE Number of bytes sent. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.10 | INTEGER | read-only | mandatory |
| solBladeBytesReceived OBJECT-TYPE Number of bytes received. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.11 | INTEGER | read-only | mandatory |
| solBladeDestinationMAC OBJECT-TYPE MAC address of the blade. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.12 | OCTET STRING | read-only | mandatory |
| solBladeConsoleUserId OBJECT-TYPE Sol console user name. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.13 | OCTET STRING | read-only | mandatory |
| solBladeConsoleLoginFrom OBJECT-TYPE The location information from where the SOL console is logged in. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.14 | OCTET STRING | read-only | mandatory |
| solBladeConsoleLoginStart OBJECT-TYPE The time that SOL console starts. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.15 | OCTET STRING | read-only | mandatory |
| solBladeConsoleLoginEnd OBJECT-TYPE The time that SOL console ends. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.16 | OCTET STRING | read-only | mandatory |
| chassisInternalNetwork OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.11 | |||
| cinsSupported OBJECT-TYPE Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported. | 1.3.6.1.4.1.2.3.51.2.4.11.1 | INTEGER | read-only | mandatory |
| cinGlobalEnable OBJECT-TYPE Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: MM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces. | 1.3.6.1.4.1.2.3.51.2.4.11.2 | INTEGER {cinDisabled(0), cinEnabled(1)} | read-write | mandatory |
| cinTable OBJECT-TYPE Chassis Internal Network (CIN) configuration table. | 1.3.6.1.4.1.2.3.51.2.4.11.3 | not-accessible | mandatory | |
| cinEntry OBJECT-TYPE Chassis Internal Network (CIN) table entry. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1 | not-accessible | mandatory | |
| cinIndex OBJECT-TYPE Chassis Internal Network (CIN) table index. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.1 | INTEGER | read-only | mandatory |
| cinDefExists OBJECT-TYPE Indicates if a Chassis Internal Network (CIN) definition exists for this index or not. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| cinDelete OBJECT-TYPE Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.3 | INTEGER {execute(1)} | read-write | mandatory |
| cinEnable OBJECT-TYPE Disable or enable a Chassis Internal Network (CIN) definition. Enabled: MM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| cinId OBJECT-TYPE This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.5 | INTEGER | read-write | mandatory |
| cinIpAddress OBJECT-TYPE Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the MM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of MM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.6 | IpAddress | read-write | mandatory |
| cinIpv6Address OBJECT-TYPE Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.7 | InetAddressIPv6 | read-write | mandatory |
| cinStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.11.4 | |||
| cinStatusTable OBJECT-TYPE Table of Chassis Internal Network (CIN) status entry information. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1 | not-accessible | mandatory | |
| cinStatusEntry OBJECT-TYPE Chassis Internal Network (CIN) status table entry. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1 | not-accessible | mandatory | |
| cinStatusIndex OBJECT-TYPE The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1 | INTEGER | read-only | mandatory |
| cinStatusString OBJECT-TYPE Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the MM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2 | OCTET STRING | read-only | mandatory |
| restartReset OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.7 | |||
| restartSPImmediately OBJECT-TYPE Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.4 | INTEGER {execute(1)} | read-write | mandatory |
| restartStandbyMM OBJECT-TYPE Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.7.5 | INTEGER {execute(1)} | read-write | mandatory |
| switchOverRedundantMM OBJECT-TYPE Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM. | 1.3.6.1.4.1.2.3.51.2.7.7 | INTEGER {execute(1)} | read-write | mandatory |
| resetSPConfigAndRestart OBJECT-TYPE Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.20 | INTEGER {execute(1)} | read-write | mandatory |
| resetSPConfigAndRestartSaveLogs OBJECT-TYPE Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.21 | INTEGER {execute(1)} | read-write | mandatory |
| components OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22 | |||
| processorBlade OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1 | |||
| bladePolicyControl OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.4 | |||
| bladePolicyControlTable OBJECT-TYPE Table of blade power policy control information. Contains power on/off enablement status for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1 | not-accessible | mandatory | |
| bladePolicyControlEntry OBJECT-TYPE Power policy control entry | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1 | not-accessible | mandatory | |
| policyControlIndex OBJECT-TYPE Blade power policy control index. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1 | INTEGER | read-only | mandatory |
| policyControlBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| policyControlBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| policyControlBladePowerState OBJECT-TYPE The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| policyControlBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| policyControlBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6 | OCTET STRING | read-only | mandatory |
| policyLocalPowerControlEnable OBJECT-TYPE Blade local power policy control enablement status. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| policyWakeOnLanControlEnable OBJECT-TYPE Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bladePolicy OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.4.2 | |||
| bladePolicyLocalPowerControlEnable OBJECT-TYPE Blade local power control enablement status policy. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyWakeOnLanControlEnable OBJECT-TYPE Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.4 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bladeMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.5 | |||
| bladeSystemStatusTable OBJECT-TYPE Table of blade status information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1 | not-accessible | mandatory | |
| bladeSystemStatusEntry OBJECT-TYPE Blade system status entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1 | not-accessible | mandatory | |
| bladeStatusIndex OBJECT-TYPE Blade system status index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1 | INTEGER | read-only | mandatory |
| bladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| bladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| bladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6 | OCTET STRING | read-only | mandatory |
| bladeRemotePowerEnable OBJECT-TYPE Remote power state for the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| bladeConnectionType OBJECT-TYPE Connection type of the expansion card number one. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeRemoteWakeOnLanEnable OBJECT-TYPE Remote wake on LAN state for the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-only | mandatory |
| bladeServerExpansion OBJECT-TYPE This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bladeWidth OBJECT-TYPE The width of the blade including any supplement blade attached to it | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15 | INTEGER | read-only | mandatory |
| bladeServerExpansion2 OBJECT-TYPE This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bladeConnectionType2 OBJECT-TYPE Connection type of the expansion card number 2. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType3 OBJECT-TYPE Connection type of the expansion card number 3. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType4 OBJECT-TYPE Connection type of the expansion card number 4. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType5 OBJECT-TYPE Connection type of the expansion card number 5. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeHighSpeedConnectionType OBJECT-TYPE Connection type of the high speed expansion card number 1. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6), infinibandPassThrough(7)} | read-only | mandatory |
| bladeIOCompatibility OBJECT-TYPE I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51 | OCTET STRING | read-only | mandatory |
| bladeInventoryReady OBJECT-TYPE When a blade management controller or the MM is reset, the blade inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52 | INTEGER {notReady(0), ready(1)} | read-only | mandatory |
| bladeHealthSummaryTable OBJECT-TYPE Table of blade health summary information. Contains information about the overall blade health status. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2 | not-accessible | mandatory | |
| bladeHealthSummaryEntry OBJECT-TYPE Blade health summary entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1 | not-accessible | mandatory | |
| bladeHealthSummaryIndex OBJECT-TYPE Blade health summary index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1 | INTEGER | read-only | mandatory |
| bladeHealthSummaryBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeHealthSummarySeverity OBJECT-TYPE System health summary severity. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3 | OCTET STRING | read-only | mandatory |
| bladeHealthSummaryDescription OBJECT-TYPE System health summary description. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4 | OCTET STRING | read-only | mandatory |
| bladeHealthSummaryDateTime OBJECT-TYPE System health summary date time. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeHealthSummaryEventID OBJECT-TYPE System health summary event ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.6 | OCTET STRING | read-only | mandatory |
| bladeTemperaturesTable OBJECT-TYPE Table of blade temperatures information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3 | not-accessible | mandatory | |
| bladeTemperaturesEntry OBJECT-TYPE Blade temperatures table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1 | not-accessible | mandatory | |
| temperatureIndex OBJECT-TYPE Blade temperatures table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1 | INTEGER | read-only | mandatory |
| temperatureBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| temperatureBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| temperatureBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5 | OCTET STRING | read-only | mandatory |
| temperatureCPU1 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6 | OCTET STRING | read-only | mandatory |
| temperatureCPU2 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7 | OCTET STRING | read-only | mandatory |
| temperatureCPU3 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8 | OCTET STRING | read-only | mandatory |
| temperatureCPU4 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9 | OCTET STRING | read-only | mandatory |
| temperatureDASD1 OBJECT-TYPE The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10 | OCTET STRING | read-only | mandatory |
| bladeSensorTempCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12 | OCTET STRING | read-only | mandatory |
| bladeSensor2Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13 | OCTET STRING | read-only | mandatory |
| bladeSensor3Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14 | OCTET STRING | read-only | mandatory |
| bladeSensor4Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15 | OCTET STRING | read-only | mandatory |
| bladeSensor5Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16 | OCTET STRING | read-only | mandatory |
| bladeSensor6Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17 | OCTET STRING | read-only | mandatory |
| bladeSensor7Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18 | OCTET STRING | read-only | mandatory |
| bladeSensor8Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19 | OCTET STRING | read-only | mandatory |
| bladeSensor9Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20 | OCTET STRING | read-only | mandatory |
| bladeTemperatureThresholdsTable OBJECT-TYPE Table of blade temperature thresholds information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4 | not-accessible | mandatory | |
| bladeTemperatureThresholdsEntry OBJECT-TYPE Blade temperature thresholds table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1 | not-accessible | mandatory | |
| temperatureThresholdIndex OBJECT-TYPE Blade temperature threshold table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 | INTEGER | read-only | mandatory |
| temperatureThresholdBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| temperatureThresholdBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureThresholdBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| temperatureThresholdBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5 | OCTET STRING | read-only | mandatory |
| temperatureCPU1HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 | OCTET STRING | read-only | mandatory |
| temperatureCPU1Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 | OCTET STRING | read-only | mandatory |
| temperatureCPU1WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 | OCTET STRING | read-only | mandatory |
| temperatureCPU2HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9 | OCTET STRING | read-only | mandatory |
| temperatureCPU2Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 | OCTET STRING | read-only | mandatory |
| temperatureCPU2WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 | OCTET STRING | read-only | mandatory |
| temperatureCPU3HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 | OCTET STRING | read-only | mandatory |
| temperatureCPU3Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 | OCTET STRING | read-only | mandatory |
| temperatureCPU3WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 | OCTET STRING | read-only | mandatory |
| temperatureCPU4HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 | OCTET STRING | read-only | mandatory |
| temperatureCPU4Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 | OCTET STRING | read-only | mandatory |
| temperatureCPU4WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 | OCTET STRING | read-only | mandatory |
| temperatureDASD1HardShutdown OBJECT-TYPE The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 | OCTET STRING | read-only | mandatory |
| temperatureDASD1Warning OBJECT-TYPE The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 | OCTET STRING | read-only | mandatory |
| temperatureDASD1WarningReset OBJECT-TYPE The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 | OCTET STRING | read-only | mandatory |
| bladeTempThresholdSensorCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureSensor1HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 | OCTET STRING | read-only | mandatory |
| temperatureSensor1Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 | OCTET STRING | read-only | mandatory |
| temperatureSensor1WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 | OCTET STRING | read-only | mandatory |
| temperatureSensor2HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 | OCTET STRING | read-only | mandatory |
| temperatureSensor2Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 | OCTET STRING | read-only | mandatory |
| temperatureSensor2WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 | OCTET STRING | read-only | mandatory |
| temperatureSensor3HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 | OCTET STRING | read-only | mandatory |
| temperatureSensor3Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 | OCTET STRING | read-only | mandatory |
| temperatureSensor3WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 | OCTET STRING | read-only | mandatory |
| temperatureSensor4HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 | OCTET STRING | read-only | mandatory |
| temperatureSensor4Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 | OCTET STRING | read-only | mandatory |
| temperatureSensor4WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 | OCTET STRING | read-only | mandatory |
| temperatureSensor5HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 | OCTET STRING | read-only | mandatory |
| temperatureSensor5Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 | OCTET STRING | read-only | mandatory |
| temperatureSensor5WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 | OCTET STRING | read-only | mandatory |
| temperatureSensor6HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 | OCTET STRING | read-only | mandatory |
| temperatureSensor6Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 | OCTET STRING | read-only | mandatory |
| temperatureSensor6WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 | OCTET STRING | read-only | mandatory |
| temperatureSensor7HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40 | OCTET STRING | read-only | mandatory |
| temperatureSensor7Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41 | OCTET STRING | read-only | mandatory |
| temperatureSensor7WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42 | OCTET STRING | read-only | mandatory |
| temperatureSensor8HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43 | OCTET STRING | read-only | mandatory |
| temperatureSensor8Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44 | OCTET STRING | read-only | mandatory |
| temperatureSensor8WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45 | OCTET STRING | read-only | mandatory |
| temperatureSensor9HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46 | OCTET STRING | read-only | mandatory |
| temperatureSensor9Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47 | OCTET STRING | read-only | mandatory |
| temperatureSensor9WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48 | OCTET STRING | read-only | mandatory |
| bladeVoltagesTable OBJECT-TYPE Table of blade voltages information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5 | not-accessible | mandatory | |
| bladeVoltagesEntry OBJECT-TYPE Blade voltages table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1 | not-accessible | mandatory | |
| voltageIndex OBJECT-TYPE Blade voltages table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1 | INTEGER | read-only | mandatory |
| voltageBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| voltageBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| voltageBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| voltageBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5 | OCTET STRING | read-only | mandatory |
| bladePlus5Volt OBJECT-TYPE +5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3Volt OBJECT-TYPE +3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7 | OCTET STRING | read-only | mandatory |
| bladePlus12Volt OBJECT-TYPE +12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5Volt OBJECT-TYPE +2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5Volt OBJECT-TYPE +1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25Volt OBJECT-TYPE +1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12 | OCTET STRING | read-only | mandatory |
| bladeVRM1Volt OBJECT-TYPE VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13 | OCTET STRING | read-only | mandatory |
| bladeSensorVoltCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15 | OCTET STRING | read-only | mandatory |
| bladeSensor2Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16 | OCTET STRING | read-only | mandatory |
| bladeSensor3Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17 | OCTET STRING | read-only | mandatory |
| bladeSensor4Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18 | OCTET STRING | read-only | mandatory |
| bladeSensor5Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19 | OCTET STRING | read-only | mandatory |
| bladeSensor6Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20 | OCTET STRING | read-only | mandatory |
| bladeSensor7Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21 | OCTET STRING | read-only | mandatory |
| bladeSensor8Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22 | OCTET STRING | read-only | mandatory |
| bladeSensor9Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23 | OCTET STRING | read-only | mandatory |
| bladeSensor10Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24 | OCTET STRING | read-only | mandatory |
| bladeSensor11Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25 | OCTET STRING | read-only | mandatory |
| bladeSensor12Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26 | OCTET STRING | read-only | mandatory |
| bladeSensor13Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27 | OCTET STRING | read-only | mandatory |
| bladeSensor14Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28 | OCTET STRING | read-only | mandatory |
| bladeSensor15Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29 | OCTET STRING | read-only | mandatory |
| bladeSensor16Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30 | OCTET STRING | read-only | mandatory |
| bladeSensor17Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31 | OCTET STRING | read-only | mandatory |
| bladeSensor18Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32 | OCTET STRING | read-only | mandatory |
| bladeSensor19Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33 | OCTET STRING | read-only | mandatory |
| bladeSensor20Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34 | OCTET STRING | read-only | mandatory |
| bladeSensor21Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35 | OCTET STRING | read-only | mandatory |
| bladeSensor22Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36 | OCTET STRING | read-only | mandatory |
| bladeSensor23Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37 | OCTET STRING | read-only | mandatory |
| bladeSensor24Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38 | OCTET STRING | read-only | mandatory |
| bladeSensor25Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39 | OCTET STRING | read-only | mandatory |
| bladeSensor26Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40 | OCTET STRING | read-only | mandatory |
| bladeSensor27Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41 | OCTET STRING | read-only | mandatory |
| bladeSensor28Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42 | OCTET STRING | read-only | mandatory |
| bladeSensor29Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43 | OCTET STRING | read-only | mandatory |
| bladeSensor30Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44 | OCTET STRING | read-only | mandatory |
| bladeVoltageThresholdsTable OBJECT-TYPE Table of blade VoltageThresholds information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6 | not-accessible | mandatory | |
| bladeVoltageThresholdsEntry OBJECT-TYPE Blade voltage thresholds table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1 | not-accessible | mandatory | |
| voltageThresholdIndex OBJECT-TYPE Blade voltage thresholds table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1 | INTEGER | read-only | mandatory |
| voltageThresholdBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| voltageThresholdBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| voltageThresholdBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| voltageThresholdBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5 | OCTET STRING | read-write | mandatory |
| bladePlus5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6 | OCTET STRING | read-only | mandatory |
| bladePlus5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9 | OCTET STRING | read-only | mandatory |
| bladePlus12VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10 | OCTET STRING | read-only | mandatory |
| bladePlus12VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19 | OCTET STRING | read-only | mandatory |
| bladeVoltThresholdSensorCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23 | OCTET STRING | read-only | mandatory |
| bladeSensor1VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24 | OCTET STRING | read-only | mandatory |
| bladeSensor2VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25 | OCTET STRING | read-only | mandatory |
| bladeSensor2VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26 | OCTET STRING | read-only | mandatory |
| bladeSensor3VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27 | OCTET STRING | read-only | mandatory |
| bladeSensor3VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28 | OCTET STRING | read-only | mandatory |
| bladeSensor4VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29 | OCTET STRING | read-only | mandatory |
| bladeSensor4VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30 | OCTET STRING | read-only | mandatory |
| bladeSensor5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31 | OCTET STRING | read-only | mandatory |
| bladeSensor5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32 | OCTET STRING | read-only | mandatory |
| bladeSensor6VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33 | OCTET STRING | read-only | mandatory |
| bladeSensor6VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34 | OCTET STRING | read-only | mandatory |
| bladeSensor7VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35 | OCTET STRING | read-only | mandatory |
| bladeSensor7VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36 | OCTET STRING | read-only | mandatory |
| bladeSensor8VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37 | OCTET STRING | read-only | mandatory |
| bladeSensor8VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38 | OCTET STRING | read-only | mandatory |
| bladeSensor9VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39 | OCTET STRING | read-only | mandatory |
| bladeSensor9VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40 | OCTET STRING | read-only | mandatory |
| bladeSensor10VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41 | OCTET STRING | read-only | mandatory |
| bladeSensor10VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42 | OCTET STRING | read-only | mandatory |
| bladeSensor11VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43 | OCTET STRING | read-only | mandatory |
| bladeSensor11VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44 | OCTET STRING | read-only | mandatory |
| bladeSensor12VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45 | OCTET STRING | read-only | mandatory |
| bladeSensor12VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46 | OCTET STRING | read-only | mandatory |
| bladeSensor13VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47 | OCTET STRING | read-only | mandatory |
| bladeSensor13VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48 | OCTET STRING | read-only | mandatory |
| bladeSensor14VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49 | OCTET STRING | read-only | mandatory |
| bladeSensor14VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50 | OCTET STRING | read-only | mandatory |
| bladeSensor15VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51 | OCTET STRING | read-only | mandatory |
| bladeSensor15VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52 | OCTET STRING | read-only | mandatory |
| bladeSensor16VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53 | OCTET STRING | read-only | mandatory |
| bladeSensor16VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54 | OCTET STRING | read-only | mandatory |
| bladeSensor17VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55 | OCTET STRING | read-only | mandatory |
| bladeSensor17VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56 | OCTET STRING | read-only | mandatory |
| bladeSensor18VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57 | OCTET STRING | read-only | mandatory |
| bladeSensor18VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58 | OCTET STRING | read-only | mandatory |
| bladeSensor19VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59 | OCTET STRING | read-only | mandatory |
| bladeSensor19VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60 | OCTET STRING | read-only | mandatory |
| bladeSensor20VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61 | OCTET STRING | read-only | mandatory |
| bladeSensor20VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62 | OCTET STRING | read-only | mandatory |
| bladeSensor21VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63 | OCTET STRING | read-only | mandatory |
| bladeSensor21VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64 | OCTET STRING | read-only | mandatory |
| bladeSensor22VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65 | OCTET STRING | read-only | mandatory |
| bladeSensor22VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66 | OCTET STRING | read-only | mandatory |
| bladeSensor23VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67 | OCTET STRING | read-only | mandatory |
| bladeSensor23VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68 | OCTET STRING | read-only | mandatory |
| bladeSensor24VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69 | OCTET STRING | read-only | mandatory |
| bladeSensor24VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70 | OCTET STRING | read-only | mandatory |
| bladeSensor25VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71 | OCTET STRING | read-only | mandatory |
| bladeSensor25VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72 | OCTET STRING | read-only | mandatory |
| bladeSensor26VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73 | OCTET STRING | read-only | mandatory |
| bladeSensor26VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74 | OCTET STRING | read-only | mandatory |
| bladeSensor27VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75 | OCTET STRING | read-only | mandatory |
| bladeSensor27VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76 | OCTET STRING | read-only | mandatory |
| bladeSensor28VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77 | OCTET STRING | read-only | mandatory |
| bladeSensor28VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78 | OCTET STRING | read-only | mandatory |
| bladeSensor29VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79 | OCTET STRING | read-only | mandatory |
| bladeSensor29VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80 | OCTET STRING | read-only | mandatory |
| bladeSensor30VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81 | OCTET STRING | read-only | mandatory |
| bladeSensor30VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82 | OCTET STRING | read-only | mandatory |
| bladePowerRestart OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.6 | |||
| bladePowerRestartTable OBJECT-TYPE Table of blade remote power control information. Contains power on/off enablement status for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1 | not-accessible | mandatory | |
| bladePowerRestartEntry OBJECT-TYPE Blade power restart table entry | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1 | not-accessible | mandatory | |
| powerRestartIndex OBJECT-TYPE Blade power restart table index. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1 | INTEGER | read-only | mandatory |
| powerRestartBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| powerRestartBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| powerRestartBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) is returned. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| powerRestartBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| powerRestartBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6 | OCTET STRING | read-only | mandatory |
| powerOnOffBlade OBJECT-TYPE Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s) | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7 | INTEGER {off(0), on(1), softoff(2)} | read-write | mandatory |
| restartBlade OBJECT-TYPE Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeSMP OBJECT-TYPE Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeNMI OBJECT-TYPE Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeClearNVRAM OBJECT-TYPE Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeInvokeDiags OBJECT-TYPE Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeInvokeDiagsFromDefaultBootList OBJECT-TYPE Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeToSMSBootMenu OBJECT-TYPE Restart a blade to SMS boot menu. This option is not supported on all blades, and at the time of this MIB definition was only supported on POWER blades. This object is deprecated and please use the bladePowerEnableSMSBootMenu object. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14 | INTEGER {execute(1)} | read-write | deprecated |
| bladePowerEnableSMSBootMenu OBJECT-TYPE Enables/disables a blade restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all blades, and at the time of this MIB definition was only supported on POWER blades. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladeConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.7 | |||
| bladeConfigurationTable OBJECT-TYPE Table of blade configuration information. Contains boot mode and auto power on/off settings for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1 | not-accessible | mandatory | |
| bladeConfigurationEntry OBJECT-TYPE Blade configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1 | not-accessible | mandatory | |
| configurationIndex OBJECT-TYPE Blade configuration table index. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1 | INTEGER | read-only | mandatory |
| configurationBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| configurationBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| configurationBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| configurationBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5 | OCTET STRING | read-write | mandatory |
| configurationBladeActiveBootMode OBJECT-TYPE Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-only | mandatory |
| configurationBladePendingBootMode OBJECT-TYPE Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-write | mandatory |
| configurationBladeAutoPowerOn OBJECT-TYPE Blade auto-power on policy. - restore: blade will be powered on which were previously on. - auto: blade will automatically be powered on when power is applied to the chassis. - manual: blade will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.9 | INTEGER {restore(1), auto(2), manual(3), notApplicable(255)} | read-write | mandatory |
| configurationBladePowerOnRestartDelay OBJECT-TYPE Restart delay (in seconds) when power is applied to a blade. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.10 | INTEGER (0..32767) | read-write | mandatory |
| bladePowerManagementPolicy OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.7.2 | |||
| powerManagementPolicy OBJECT-TYPE Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails. Please see the powerPolicyTable for more information regarding this setting. | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.1 | INTEGER {power-module-redundancy(0), power-module-redundancy-throttle(1), basic(2), power-source-redundancy(16), power-source-redundancy-throttle(17)} | read-write | mandatory |
| acousticMode OBJECT-TYPE Acoustic mode setting for thermal conditions. A setting of disabled (0), disables this feature. A setting of acoustic-quiet-level1 (5) is the least restrictive and the least quiet sound level. A setting of acoustic-quiet-level5 (1) is the most restrictive and the most quiet sound level. Some values may not be valid on some chassis. A bad value will be returned in this case. | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.3 | INTEGER {disabled(0), acoustic-quiet-level1(1), acoustic-quiet-level2(2), acoustic-quiet-level3(3), acoustic-quiet-level4(4), acoustic-quiet-level5(5)} | read-write | mandatory |
| bladeBootCountPowerOnTime OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.10 | |||
| bladeBootCountPowerOnTimeTable OBJECT-TYPE Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1 | not-accessible | mandatory | |
| bladeBootCountPowerOnTimeEntry OBJECT-TYPE The number of boots for the blade and the number of seconds the blade has been powered on. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1 | not-accessible | mandatory | |
| bootCountPowerOnTimeBladeIndex OBJECT-TYPE Blade boot count/Power On Time table index. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1 | INTEGER | read-only | mandatory |
| bootCountPowerOnTimeBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bootCountPowerOnTimeBoots OBJECT-TYPE Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3 | INTEGER | read-write | mandatory |
| bootCountPowerOnTimeSecs OBJECT-TYPE Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4 | INTEGER | read-write | mandatory |
| bladeVlanId OBJECT-TYPE This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. | 1.3.6.1.4.1.2.3.51.2.22.1.11 | INTEGER | read-write | mandatory |
| bladeNetworkConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.12 | |||
| bladeIPv4ConfigTable OBJECT-TYPE Table of all blades' network interfaces. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5 | not-accessible | mandatory | |
| bladeIPv4ConfigEntry OBJECT-TYPE Blade configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1 | not-accessible | mandatory | |
| bladeIPv4ConfigIndex OBJECT-TYPE The blade's slot number. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.1 | INTEGER | read-only | mandatory |
| bladeIPv4ConfigPortIndex OBJECT-TYPE The physical port number of the given entry. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.2 | INTEGER | read-only | mandatory |
| bladeIPv4ConfigPortLabel OBJECT-TYPE Show string label that identifies the interface. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.3 | OCTET STRING | read-only | mandatory |
| bladeIPv4ConfigPhysicalLinkStatus OBJECT-TYPE Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.4 | INTEGER {down(0), up(1), notApplicable(255)} | read-only | mandatory |
| bladeIPv4ConfigPhysicalLinkState OBJECT-TYPE Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, bladeIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.5 | INTEGER {down(0), up(1), loopback(2), notApplicable(255)} | read-write | mandatory |
| bladeIPv4ConfigIPAddr OBJECT-TYPE Show/modify current IP address of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.6 | IpAddress | read-write | mandatory |
| bladeIPv4ConfigSubnetMask OBJECT-TYPE Show or modifie current subnet mask of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.7 | IpAddress | read-write | mandatory |
| bladeIPv4ConfigGatewayAddr OBJECT-TYPE Show or modify current IP gateway of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.8 | IpAddress | read-write | mandatory |
| bladeIPv4ConfigVlanId OBJECT-TYPE This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.9 | INTEGER | read-write | mandatory |
| bladeIPv4ConfigDHCPEnable OBJECT-TYPE IP config method on the blade network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.10 | INTEGER {useStatic(0), useDhcp(1), tryDhcpThenTryStatic(2), notApplicable(255)} | read-write | mandatory |
| bladeIPv4ConfigMACAddr OBJECT-TYPE Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'. | 1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.11 | OCTET STRING | read-only | mandatory |
| bladeIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.12.10 | |||
| bladeIPv6ConfigTable OBJECT-TYPE A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1 | not-accessible | mandatory | |
| bladeIPv6ConfigEntry OBJECT-TYPE IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1 | not-accessible | mandatory | |
| bladeIPv6ConfigIndex OBJECT-TYPE The blade's slot number | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1 | INTEGER | read-only | mandatory |
| bladeIPv6ConfigPortIndex OBJECT-TYPE The physical port number of the given entry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2 | INTEGER | read-only | mandatory |
| bladeIPv6ConfigEnabled OBJECT-TYPE Enables/Disables IPv6 support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6ConfigStatic OBJECT-TYPE Enables/Disables IPv6 static configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeDHCPv6ConfigEnabled OBJECT-TYPE Enables/Disables DHCPv6 address configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6ConfigStatelessEnabled OBJECT-TYPE Enables/Disables IPv6 stateless auto-configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6AddressTable OBJECT-TYPE A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2 | not-accessible | mandatory | |
| bladeIPv6AddressEntry OBJECT-TYPE The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1 | not-accessible | mandatory | |
| bladeIPv6AddressIndex OBJECT-TYPE The blade's slot number. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1 | INTEGER | read-only | mandatory |
| bladeIPv6AddressPortIndex OBJECT-TYPE The blade's physical port number for the given entry. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2 | INTEGER | read-only | mandatory |
| bladeIPv6AddressEntryIndex OBJECT-TYPE The blade's address entry index. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3 | INTEGER | read-only | mandatory |
| bladeIPv6AddressType OBJECT-TYPE The address type. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4 | INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)} | read-only | mandatory |
| bladeIPv6Address OBJECT-TYPE The assigned IPv6 address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5 | InetAddressIPv6 | read-write | mandatory |
| bladeIPv6AddressPrefixLen OBJECT-TYPE The prefix length for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6 | INTEGER (1..128) | read-write | mandatory |
| bladeIPv6AddressDefaultRoute OBJECT-TYPE The default route used for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7 | InetAddressIPv6 | read-write | mandatory |
| bladeBayDataTable OBJECT-TYPE Table of blade bay data (BBD) information. | 1.3.6.1.4.1.2.3.51.2.22.1.13 | not-accessible | mandatory | |
| bladeBayDataEntry OBJECT-TYPE Blade bay data (BBD) table entry. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1 | not-accessible | mandatory | |
| bayDataIndex OBJECT-TYPE Blade bay data (BBD) table index. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.1 | INTEGER | read-only | mandatory |
| bayDataBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bayDataBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bayDataBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| bayDataBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.5 | OCTET STRING | read-only | mandatory |
| bayData OBJECT-TYPE A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.6 | OCTET STRING | read-write | mandatory |
| bayDataBladeStatus OBJECT-TYPE This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.7 | INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)} | read-only | mandatory |
| bladeSPEthOverUSBInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.14 | |||
| spEthOverUSBInterfaceTable OBJECT-TYPE Table of blade Service Processor's Ethernet over USB interface. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1 | not-accessible | mandatory | |
| spEthOverUSBInterfaceEntry OBJECT-TYPE Blade Service Processor's Ethernet over USB interface entry. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1 | not-accessible | mandatory | |
| spEthOverUSBInterfaceIndex OBJECT-TYPE Service Processor's Ethernet over USB interface table index. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1 | INTEGER | read-only | mandatory |
| spEthOverUSBInterfaceBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2 | OCTET STRING | read-only | mandatory |
| spEthOverUSBInterfaceBladeExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| spEthOverUSBInterfaceBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6 | OCTET STRING | read-only | mandatory |
| spEthOverUSBInterfaceEnable OBJECT-TYPE This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bootDeviceInfoTable OBJECT-TYPE Table of blade boot device information. Contains info for the boot devices for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.15 | not-accessible | mandatory | |
| bootDeviceInfoEntry OBJECT-TYPE Boot device entry | 1.3.6.1.4.1.2.3.51.2.22.1.15.1 | not-accessible | mandatory | |
| bootInfoTopologyIndex OBJECT-TYPE The unique identifier for a node containing boot devices in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| bootDeviceIndex OBJECT-TYPE An index for the boot device for the given topology id. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.2 | INTEGER (0..255) | read-only | mandatory |
| bootDeviceId OBJECT-TYPE The device Id of the boot device. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.3 | OCTET STRING | read-only | mandatory |
| bootDeviceActive OBJECT-TYPE Specifies whether the boot device is active. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.4 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bootDevicePresence OBJECT-TYPE Specifies whether the boot device is present. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.5 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bootDeviceLabel OBJECT-TYPE The device label of the boot device. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.6 | OCTET STRING | read-only | mandatory |
| bootDeviceUserLabel OBJECT-TYPE The user label of the boot device. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.7 | OCTET STRING | read-only | mandatory |
| bootDeviceOrder OBJECT-TYPE The sequence number in boot order of the boot device. 0 specifies this device is not in the boot sequence. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1.8 | INTEGER (0..255) | read-only | mandatory |
| bootSequenceInfoTable OBJECT-TYPE Table of blade boot sequence information. Contains the boot sequence information for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.16 | not-accessible | mandatory | |
| bootSequenceInfoEntry OBJECT-TYPE Boot sequence entry | 1.3.6.1.4.1.2.3.51.2.22.1.16.1 | not-accessible | mandatory | |
| bootSequenceInfoTopologyIndex OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| bootSequenceInfoMaxBootDevices OBJECT-TYPE The maximum number of boot devices. | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.2 | INTEGER (0..255) | read-only | mandatory |
| bootSequenceInfoBootSequence OBJECT-TYPE A blank delimited string of device ids in the order of the boot sequence. For example, 00000001 00000002 00000005. Note that the boot sequence list can change from a given order and can grow from a given order, but cannot be reduced in length. For example, if the sequence starts as 00000001 00000011, it could change to 00000001 00000014 or grow to 00000001 00000014 00000002. In the example above, if the 00000002 selection was no longer desired, the list should be changed to 00000001 00000014 00000014, essentially repeating the last device ID. Device ids must be listed in bootDeviceInfoTable. | 1.3.6.1.4.1.2.3.51.2.22.1.16.1.3 | OCTET STRING | read-write | mandatory |
| switchModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3 | |||
| switchModuleControl OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.1 | |||
| smControlTable OBJECT-TYPE Switch module control table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1 | not-accessible | mandatory | |
| smControlEntry OBJECT-TYPE Switch module control table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1 | not-accessible | mandatory | |
| smControlIndex OBJECT-TYPE Switch module control table index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1 | INTEGER | read-only | mandatory |
| switchModuleControlId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smPostResultsAvailable OBJECT-TYPE Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smPostResultsValue OBJECT-TYPE The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4 | OCTET STRING | read-only | mandatory |
| switchModuleMemDiagEnableDisable OBJECT-TYPE Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5 | INTEGER {enabled(0), disabled(1)} | read-write | deprecated |
| smCfgCtrlEnableDisable OBJECT-TYPE Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smExtEthPortsEnableDisable OBJECT-TYPE Switch module non-management ethernet ports enabled or disabled. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smCfgCtrlOnResetEnableDisable OBJECT-TYPE Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9 | INTEGER {enabled(0), disabled(1)} | read-write | mandatory |
| smHealthState OBJECT-TYPE The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| smPMState OBJECT-TYPE The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the MM. pending - Protected Mode has been activated on the MM but not yet on the switch module. active - Protected Mode is active on both the switch module and the MM. attention - Protected Mode is enabled on the switch module but not on the MM. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16 | INTEGER {disabled(0), pending(1), attention(2), active(3), notApplicable(255)} | read-only | mandatory |
| smPMCtrlEnableDisable OBJECT-TYPE MM Protected Mode permission for the switch module. disabled - allow MM to disable Protected Mode Permission for the switch module. enabled - allow MM to grant Protected Mode Permission for the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smIOCompatibility OBJECT-TYPE The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18 | OCTET STRING | read-only | mandatory |
| smPingTable OBJECT-TYPE Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.1.2 | not-accessible | mandatory | |
| smPingEntry OBJECT-TYPE Represents a single address that can be pinged | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1 | not-accessible | mandatory | |
| smPingIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1 | INTEGER | read-only | mandatory |
| smPingAddressEntryIndex OBJECT-TYPE The switch module's address entry index | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2 | INTEGER | read-only | mandatory |
| smPingAddress OBJECT-TYPE The switch module's IPv4 or IPv6 address | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3 | OCTET STRING | read-only | mandatory |
| smPingAddressExecute OBJECT-TYPE Pings the given IP address. NOTE: The GET operation for this object is meaningless. | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4 | INTEGER {execute(1)} | read-write | mandatory |
| smPowerRestartTable OBJECT-TYPE Switch module power restart table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7 | not-accessible | mandatory | |
| smPowerRestartEntry OBJECT-TYPE Switch module power restart table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1 | not-accessible | mandatory | |
| smPowerRestartIndex OBJECT-TYPE Switch module power restart index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 | INTEGER | read-only | mandatory |
| smPowerRestartId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smSwitchExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smMACAddress OBJECT-TYPE Switch module MAC address. For IOMs which are members of a stack, this field is not applicable and should be disregarded. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 | OCTET STRING | read-only | mandatory |
| smIPAddress OBJECT-TYPE The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 | IpAddress | read-only | mandatory |
| switchModulePowerOnOff OBJECT-TYPE I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. This MIB object can not be set, if MM grants the I/O Module the Protected Mode permission and module goes into Protected Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7 | INTEGER {poweroff(0), poweron(1), shutdownInProgress(2)} | read-write | mandatory |
| smReset OBJECT-TYPE For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 | INTEGER {execute(1)} | read-write | mandatory |
| smResetToDefault OBJECT-TYPE For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunStdDiag OBJECT-TYPE To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunExtDiag OBJECT-TYPE To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunFullDiag OBJECT-TYPE To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | INTEGER {execute(1)} | read-write | mandatory |
| smPowerOnRestartDelay OBJECT-TYPE Restart delay (in seconds) when power is applied to a switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.15 | INTEGER (0..32767) | read-write | mandatory |
| smSwitchWidth OBJECT-TYPE Switch module width. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21 | INTEGER | read-only | mandatory |
| smManufacturingID OBJECT-TYPE Switch module hardware VPD manufacturing ID. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22 | OCTET STRING | read-only | mandatory |
| smStackingModeState OBJECT-TYPE The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23 | INTEGER {standby(0), member(1), master(2), notApplicable(255)} | read-only | mandatory |
| smStackingModeInfo OBJECT-TYPE A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityTable OBJECT-TYPE Switch module control table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10 | not-accessible | mandatory | |
| smIOCompatibilityEntry OBJECT-TYPE Switch module IO compatibility table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1 | not-accessible | mandatory | |
| smIOCompatibilityIndex OBJECT-TYPE Switch module IO compatibility index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1 | INTEGER | read-only | mandatory |
| smIOCompatibilityId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smIOCompatibilityModuleBay OBJECT-TYPE The modules (identified by an id string) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module). | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityModulePower OBJECT-TYPE The power state of the module specified in smIOCompatibilityModuleBay. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityModuleFabricType OBJECT-TYPE The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot). | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityStatus OBJECT-TYPE The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityTargetTopologyPath OBJECT-TYPE The unique identifier for a component which communicates with this IO module. This is the same component identified with an id string in the smIOCompatibilityModuleBay column. The installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.7 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| switchModuleConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2 | |||
| switchMgmtNetworkCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1 | |||
| switchCurrentNwCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1 | |||
| smCurrentIPInfoTable OBJECT-TYPE Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1 | not-accessible | mandatory | |
| smCurrentIPInfoEntry OBJECT-TYPE Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1 | not-accessible | mandatory | |
| smCurrentIPInfoIndex OBJECT-TYPE Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1 | INTEGER | read-only | mandatory |
| smCurrentIPInfoId OBJECT-TYPE The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smCurrentIPInfoExists OBJECT-TYPE Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smCurrentIPInfoPowerState OBJECT-TYPE Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4 | INTEGER {off(0), on(1), shutdownInProgress(2)} | read-only | mandatory |
| smCurrentIPAddr OBJECT-TYPE The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6 | IpAddress | read-only | mandatory |
| smCurrentSubnetMask OBJECT-TYPE The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7 | IpAddress | read-only | mandatory |
| smCurrentGateway OBJECT-TYPE The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8 | IpAddress | read-only | mandatory |
| smCurrentIPConfigMethod OBJECT-TYPE The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9 | INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)} | read-only | mandatory |
| switchNewNwCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2 | |||
| smNewIPInfoTable OBJECT-TYPE Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1 | not-accessible | mandatory | |
| smNewIPInfoEntry OBJECT-TYPE Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1 | not-accessible | mandatory | |
| smNewIPInfoIndex OBJECT-TYPE Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1 | INTEGER | read-only | mandatory |
| smNewIPInfoId OBJECT-TYPE The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNewIPInfoExists OBJECT-TYPE Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNewIPInfoPowerState OBJECT-TYPE Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNewIPAddr OBJECT-TYPE The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6 | IpAddress | read-write | mandatory |
| smNewSubnetMask OBJECT-TYPE The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7 | IpAddress | read-write | mandatory |
| smNewGateway OBJECT-TYPE The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8 | IpAddress | read-write | mandatory |
| smNewIPConfigMethod OBJECT-TYPE The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9 | INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)} | read-write | mandatory |
| smNewIPConfigEnableDisable OBJECT-TYPE A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| switchIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4 | |||
| smIPv6ConfigTable OBJECT-TYPE A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1 | not-accessible | mandatory | |
| smIPv6ConfigEntry OBJECT-TYPE IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1 | not-accessible | mandatory | |
| smIPv6ConfigIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1 | INTEGER | read-only | mandatory |
| smIPv6ConfigEnabled OBJECT-TYPE Enables/Disables IPv6 support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2 | INTEGER {enable(1)} | read-write | mandatory |
| smIPv6ConfigStatic OBJECT-TYPE Enables/Disables IPv6 static configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smDHCPv6ConfigEnabled OBJECT-TYPE Enables/Disables DHCPv6 address configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smIPv6ConfigStatelessEnabled OBJECT-TYPE Enables/Disables IPv6 stateless auto-configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smIPv6AddressTable OBJECT-TYPE A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2 | not-accessible | mandatory | |
| smIPv6AddressEntry OBJECT-TYPE The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1 | not-accessible | mandatory | |
| smIPv6AddressIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1 | INTEGER | read-only | mandatory |
| smIPv6AddressEntryIndex OBJECT-TYPE The switch module's address entry index | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2 | INTEGER | read-only | mandatory |
| smIPv6AddressType OBJECT-TYPE The address type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3 | INTEGER {static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5)} | read-only | mandatory |
| smIPv6Address OBJECT-TYPE The assigned IPv6 address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4 | InetAddressIPv6 | read-only | mandatory |
| smIPv6AddressPrefixLen OBJECT-TYPE The prefix length for the given address. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5 | INTEGER | read-only | mandatory |
| smIPv6AddressDefaultRoute OBJECT-TYPE The default route used for the given address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6 | InetAddressIPv6 | read-only | mandatory |
| smIPv6StaticConfigTable OBJECT-TYPE Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3 | not-accessible | mandatory | |
| smIPv6StaticConfigEntry OBJECT-TYPE The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1 | not-accessible | mandatory | |
| smIPv6StaticIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1 | INTEGER | read-only | mandatory |
| smIPv6StaticAddress OBJECT-TYPE The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2 | InetAddressIPv6 | read-write | mandatory |
| smIPv6StaticAddressPrefixLen OBJECT-TYPE The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3 | INTEGER | read-write | mandatory |
| smIPv6StaticAddressDefaultRoute OBJECT-TYPE The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4 | InetAddressIPv6 | read-write | mandatory |
| switchPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2 | |||
| switchModOnePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1 | |||
| smOnePortCfgTable OBJECT-TYPE Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1 | not-accessible | mandatory | |
| smOnePortCfgEntry OBJECT-TYPE Switch Module 1 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1 | not-accessible | mandatory | |
| smOnePortCfgIndex OBJECT-TYPE Switch Module 1 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1 | INTEGER | read-only | mandatory |
| smOnePortCfgLabel OBJECT-TYPE Switch Module 1 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2 | OCTET STRING | read-only | mandatory |
| smOnePortCfgType OBJECT-TYPE Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smOnePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smOnePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smOnePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mh: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6 | OCTET STRING | read-write | mandatory |
| smOnePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7 | OCTET STRING | read-only | mandatory |
| smOnePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8 | OCTET STRING | read-only | mandatory |
| smOnePortCfgMedia OBJECT-TYPE Port media type of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11 | INTEGER | read-only | mandatory |
| smOnePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12 | INTEGER | read-only | mandatory |
| smOnePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13 | OCTET STRING | read-only | mandatory |
| smOnePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14 | OCTET STRING | read-only | mandatory |
| smOnePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModTwoPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2 | |||
| smTwoPortCfgTable OBJECT-TYPE Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1 | not-accessible | mandatory | |
| smTwoPortCfgEntry OBJECT-TYPE Switch Module 2 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1 | not-accessible | mandatory | |
| smTwoPortCfgIndex OBJECT-TYPE Switch Module 2 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1 | INTEGER | read-only | mandatory |
| smTwoPortCfgLabel OBJECT-TYPE Switch Module 2 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgType OBJECT-TYPE Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smTwoPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smTwoPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smTwoPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6 | OCTET STRING | read-write | mandatory |
| smTwoPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgMedia OBJECT-TYPE Port media type of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11 | INTEGER | read-only | mandatory |
| smTwoPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12 | INTEGER | read-only | mandatory |
| smTwoPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModThreePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3 | |||
| smThreePortCfgTable OBJECT-TYPE Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1 | not-accessible | mandatory | |
| smThreePortCfgEntry OBJECT-TYPE Switch Module 3 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1 | not-accessible | mandatory | |
| smThreePortCfgIndex OBJECT-TYPE Switch Module 3 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1 | INTEGER | read-only | mandatory |
| smThreePortCfgLabel OBJECT-TYPE Switch Module 3 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2 | OCTET STRING | read-only | mandatory |
| smThreePortCfgType OBJECT-TYPE Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smThreePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smThreePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smThreePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6 | OCTET STRING | read-write | mandatory |
| smThreePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7 | OCTET STRING | read-only | mandatory |
| smThreePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8 | OCTET STRING | read-only | mandatory |
| smThreePortCfgMedia OBJECT-TYPE Port media type of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11 | INTEGER | read-only | mandatory |
| smThreePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12 | INTEGER | read-only | mandatory |
| smThreePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13 | OCTET STRING | read-only | mandatory |
| smThreePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14 | OCTET STRING | read-only | mandatory |
| smThreePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModFourPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4 | |||
| smFourPortCfgTable OBJECT-TYPE Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1 | not-accessible | mandatory | |
| smFourPortCfgEntry OBJECT-TYPE Switch Module 4 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1 | not-accessible | mandatory | |
| smFourPortCfgIndex OBJECT-TYPE Switch Module 4 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1 | INTEGER | read-only | mandatory |
| smFourPortCfgLabel OBJECT-TYPE Switch Module 4 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2 | OCTET STRING | read-only | mandatory |
| smFourPortCfgType OBJECT-TYPE Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smFourPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smFourPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smFourPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6 | OCTET STRING | read-write | mandatory |
| smFourPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7 | OCTET STRING | read-only | mandatory |
| smFourPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8 | OCTET STRING | read-only | mandatory |
| smFourPortCfgMedia OBJECT-TYPE Port media type of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11 | INTEGER | read-only | mandatory |
| smFourPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12 | INTEGER | read-only | mandatory |
| smFourPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13 | OCTET STRING | read-only | mandatory |
| smFourPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14 | OCTET STRING | read-only | mandatory |
| smFourPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| chassisTopology OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.4 | |||
| chassisResponseVersion OBJECT-TYPE Chassis response version. | 1.3.6.1.4.1.2.3.51.2.22.4.1 | INTEGER | read-only | mandatory |
| chassisFlags OBJECT-TYPE Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.2 | INTEGER {rackOrStandAlone(0), serverBlade(1)} | read-only | mandatory |
| chassisNoOfFPsSupported OBJECT-TYPE This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.18 | INTEGER | read-only | deprecated |
| chassisNoOfBayDevicesSupported OBJECT-TYPE Maximum number of bays found in the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.19 | INTEGER | read-only | mandatory |
| chassisNoOfSMsSupported OBJECT-TYPE Number of switch modules (SMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.20 | INTEGER | read-only | mandatory |
| chassisNoOfMMsSupported OBJECT-TYPE Number of management modules (MMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.21 | INTEGER | read-only | mandatory |
| chassisNoOfPMsSupported OBJECT-TYPE Number of power modules (PMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.22 | INTEGER | read-only | mandatory |
| chassisNoOfRearLEDCardsSupported OBJECT-TYPE Number of rear LED cards supported. | 1.3.6.1.4.1.2.3.51.2.22.4.23 | INTEGER | read-only | mandatory |
| chassisNoOfChassisFansSupported OBJECT-TYPE Number of chassis fans supported. | 1.3.6.1.4.1.2.3.51.2.22.4.24 | INTEGER | read-only | mandatory |
| chassisBayDevicesInstalled OBJECT-TYPE The bay devices that are installed in the chassis. The bay devices are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of bay devices supported. For devices that fill multiple bays, the bit mask will indicate the primary/lowest bay as occupied. If a device is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if devices are installed in bays 1, 5, and 13, and 14 bays are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.22.4.25 | OCTET STRING | read-only | mandatory |
| chassisSMsInstalled OBJECT-TYPE The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'. | 1.3.6.1.4.1.2.3.51.2.22.4.29 | OCTET STRING | read-only | mandatory |
| chassisMMsInstalled OBJECT-TYPE The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.30 | OCTET STRING | read-only | mandatory |
| chassisPMsInstalled OBJECT-TYPE The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.22.4.31 | OCTET STRING | read-only | mandatory |
| chassisRearLEDCardInstalled OBJECT-TYPE Indicates whether at least one rear LED card is installed. | 1.3.6.1.4.1.2.3.51.2.22.4.32 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| chassisFansInstalled OBJECT-TYPE The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.33 | OCTET STRING | read-only | mandatory |
| chassisActiveMM OBJECT-TYPE The active management module (MM). | 1.3.6.1.4.1.2.3.51.2.22.4.34 | INTEGER | read-only | mandatory |
| chassisFPsInstalled OBJECT-TYPE This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.37 | OCTET STRING | read-only | deprecated |
| chassisType OBJECT-TYPE The type of the chassis. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.38 | INTEGER {flex(101)} | read-only | mandatory |
| chassisSubtype OBJECT-TYPE The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.39 | INTEGER {tracewell4(48), tracewell8(49), tracewell7(50), flex(101), unknown(255)} | read-only | mandatory |
| chassisNoOfRearLEDCardsInstalled OBJECT-TYPE The rear LED cards that are installed on the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.52 | OCTET STRING | read-only | mandatory |
| chassisRoom OBJECT-TYPE The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination. | 1.3.6.1.4.1.2.3.51.2.22.4.53 | OCTET STRING (SIZE(0..24)) | read-write | mandatory |
| chassisName OBJECT-TYPE The name of the chassis. Maximum 15 character long plus NULL termination. | 1.3.6.1.4.1.2.3.51.2.22.4.54 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| chassisRack OBJECT-TYPE The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination. | 1.3.6.1.4.1.2.3.51.2.22.4.55 | OCTET STRING (SIZE(0..24)) | read-write | mandatory |
| chassisLowestU OBJECT-TYPE The lowest U position that is occupied in the rack. | 1.3.6.1.4.1.2.3.51.2.22.4.56 | INTEGER | read-write | mandatory |
| chassisUHeight OBJECT-TYPE The height of the chassis in 'U' units. | 1.3.6.1.4.1.2.3.51.2.22.4.57 | INTEGER | read-only | mandatory |
| managementModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.5 | |||
| mmStatusTable OBJECT-TYPE Table of the management module status. | 1.3.6.1.4.1.2.3.51.2.22.5.1 | not-accessible | mandatory | |
| mmStatusEntry OBJECT-TYPE Management module status entry. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1 | not-accessible | mandatory | |
| mmStatusIndex OBJECT-TYPE Management module status index. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.1 | INTEGER | read-only | mandatory |
| mmPresent OBJECT-TYPE Management module current status. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.2 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mmExtIpAddress OBJECT-TYPE Management module external IP address. NOTE: The IPv6 addresses assigned to the MM may be viewed with the extEthernetInterfaceIPv6 objects | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.3 | IpAddress | read-only | mandatory |
| mmPrimary OBJECT-TYPE Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.4 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mmHealthState OBJECT-TYPE The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.5 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| firmwareInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.8 | |||
| smFirmwareInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.8.1 | |||
| smFirmwareInfoTable OBJECT-TYPE Switch Module firmware image information. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1 | not-accessible | mandatory | |
| smFirmwareInfoEntry OBJECT-TYPE Switch Module firmware image information table entry | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1 | not-accessible | mandatory | |
| smFirmwareInfoIndex OBJECT-TYPE Sequence index in the firmware table. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1 | INTEGER | read-only | mandatory |
| smFirmwareInfoModIndex OBJECT-TYPE Switch Module number. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2 | INTEGER | read-only | mandatory |
| smFirmwareInfoImageIndex OBJECT-TYPE Switch Module firmware image index. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3 | INTEGER | read-only | mandatory |
| smFirmwareInfoImageName OBJECT-TYPE Switch Module firmware image name | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4 | OCTET STRING | read-write | mandatory |
| firmwareUpdate OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.9 | |||
| firmwareUpdateTarget OBJECT-TYPE Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error. | 1.3.6.1.4.1.2.3.51.2.22.9.1 | INTEGER {managementModule(0), switchModule1(11), switchModule2(12), switchModule3(13), switchModule4(14), unknown(255)} | read-write | mandatory |
| firmwareUpdateTftpServer OBJECT-TYPE If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]). | 1.3.6.1.4.1.2.3.51.2.22.9.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| firmwareUpdateFileName OBJECT-TYPE File name of the firmware file. | 1.3.6.1.4.1.2.3.51.2.22.9.3 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| firmwareUpdateStart OBJECT-TYPE Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the MM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.9.4 | INTEGER {execute(1), execute-with-reboot(2), execute-nowait(3), execute-with-reboot-nowait(4)} | read-write | mandatory |
| firmwareUpdateStatus OBJECT-TYPE Get the status of the last firmware update which was initiated through SNMP method. | 1.3.6.1.4.1.2.3.51.2.22.9.5 | OCTET STRING | read-only | mandatory |
| standbyFirmwareUpdateStatus OBJECT-TYPE Get the current status of the firmware update for the standby MM. NOTE: This only applies to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.22.9.6 | OCTET STRING | read-only | mandatory |
| firmwareImageNumber OBJECT-TYPE If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section. | 1.3.6.1.4.1.2.3.51.2.22.9.7 | INTEGER | read-write | mandatory |
| firmwareActiveImage OBJECT-TYPE If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.9.8 | INTEGER | read-write | mandatory |
| firmwareUpdateServer OBJECT-TYPE Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: cmefs.uxp Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>. Note: When updating certain switches via SFTP, only an RSA fingerprint is supported. Please see your switch documentation for more information. | 1.3.6.1.4.1.2.3.51.2.22.9.9 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| fileManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.11 | |||
| fileTopology OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.11.1 | |||
| currentDirectory OBJECT-TYPE Specifies the directory name for listing the requested files. | 1.3.6.1.4.1.2.3.51.2.22.11.1.1 | OCTET STRING | read-write | mandatory |
| fileDetailsTable OBJECT-TYPE A table of all the files in the specified directory. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2 | not-accessible | mandatory | |
| fileDetailsEntry OBJECT-TYPE File details entry. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1 | not-accessible | mandatory | |
| fileIndex OBJECT-TYPE File sequence index. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1 | INTEGER | read-only | mandatory |
| fileName OBJECT-TYPE File name. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2 | OCTET STRING | read-only | mandatory |
| fileLastUpdate OBJECT-TYPE Date of the latest file update. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3 | OCTET STRING | read-only | mandatory |
| fileSize OBJECT-TYPE File size in bytes. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4 | OCTET STRING | read-only | mandatory |
| fileManagementCmd OBJECT-TYPE This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.11.3 | OCTET STRING | read-write | mandatory |
| fileSystemSpaceAvailable OBJECT-TYPE This field displays the available space of the MM file system. | 1.3.6.1.4.1.2.3.51.2.22.11.6 | OCTET STRING | read-only | mandatory |
| cmeRemoteChassis OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.12 | |||
| cmeRemoteChassisTable OBJECT-TYPE This table is used to provide the discovered MMs based on the new, extended SLP response information. | 1.3.6.1.4.1.2.3.51.2.22.12.1 | not-accessible | mandatory | |
| cmeRemoteChassisEntry OBJECT-TYPE Remote chassis entry | 1.3.6.1.4.1.2.3.51.2.22.12.1.1 | not-accessible | mandatory | |
| cmeRemoteChassisIndex OBJECT-TYPE Remote chassis discovery sequence index. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.1 | INTEGER | read-only | mandatory |
| cmeSystemName OBJECT-TYPE System name for this discovery management module. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.2 | OCTET STRING | read-only | mandatory |
| cmeType OBJECT-TYPE Management module service processor type. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.3 | OCTET STRING | read-only | mandatory |
| cmeSerial OBJECT-TYPE Management module serial number. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.4 | OCTET STRING | read-only | mandatory |
| cmeFru OBJECT-TYPE Management module Field-Replaceable number. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.5 | OCTET STRING | read-only | mandatory |
| cmeUuid OBJECT-TYPE Management module UUID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.6 | OCTET STRING | read-only | mandatory |
| cmeSlot OBJECT-TYPE Management module slot. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.7 | OCTET STRING | read-only | mandatory |
| cmeMidPid OBJECT-TYPE Management module Mid-plane Pid. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.8 | OCTET STRING | read-only | mandatory |
| cmeMacAddress OBJECT-TYPE Management module MAC address. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.9 | OCTET STRING | read-only | mandatory |
| cmeChassisSerial OBJECT-TYPE Chassis serial number. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.10 | OCTET STRING | read-only | mandatory |
| cmeChassisFru OBJECT-TYPE Chassis Field-Replaceable number. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.11 | OCTET STRING | read-only | mandatory |
| cmeChassisMachineTypeMode OBJECT-TYPE Chassis machine type and model number. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.12 | OCTET STRING | read-only | mandatory |
| cmeSystemStatus OBJECT-TYPE Chassis status. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.13 | INTEGER {critical(0), non-Critical(2), system-Level(4), unknown(9), noResponse(170), normal(255)} | read-only | mandatory |
| cmeChassisUuid OBJECT-TYPE Chassis UUID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.14 | OCTET STRING | read-only | mandatory |
| cmeChassisMidPid OBJECT-TYPE Chassis mid-plane ID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.15 | OCTET STRING | read-only | mandatory |
| cmeChassisId OBJECT-TYPE Chassis ID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.16 | OCTET STRING | read-only | mandatory |
| cmeChassisLocation OBJECT-TYPE Chassis location information. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.17 | OCTET STRING | read-only | mandatory |
| cmeChassisRoomId OBJECT-TYPE Chassis room ID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.18 | OCTET STRING | read-only | mandatory |
| cmeChassisRackId OBJECT-TYPE Chassis rack ID. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.19 | OCTET STRING | read-only | mandatory |
| cmeChassisUser OBJECT-TYPE Chassis user information. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.20 | OCTET STRING | read-only | mandatory |
| cmeChassisFruList OBJECT-TYPE Chassis FRU list. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.21 | OCTET STRING | read-only | mandatory |
| cmeFirmwareVersion OBJECT-TYPE Firmware version of the discovery management module. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.22 | OCTET STRING | read-only | mandatory |
| cmeChassisType OBJECT-TYPE Chassis type. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.23 | OCTET STRING | read-only | mandatory |
| cmeIpv4Status OBJECT-TYPE A flag to state if IPv4 is enabled | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.24 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| cmeIpv4Addresses OBJECT-TYPE The IPv4 addresses configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.25 | OCTET STRING | read-only | mandatory |
| cmeIpv4AddressesFloat OBJECT-TYPE The floating IPv4 addresses configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.26 | OCTET STRING | read-only | mandatory |
| cmeIpv4Protocols OBJECT-TYPE The IPv4 protocols configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.27 | OCTET STRING | read-only | mandatory |
| cmeIpv6Status OBJECT-TYPE A flag to state if IPv6 is enabled | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.28 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| cmeIpv6Addresses OBJECT-TYPE The IPv6 addresses configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.29 | OCTET STRING | read-only | mandatory |
| cmeIpv6AddressesFloat OBJECT-TYPE The floating IPv6 addresses configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.30 | OCTET STRING | read-only | mandatory |
| cmeIpv6Protocols OBJECT-TYPE The IPv6 protocols configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.12.1.1.31 | OCTET STRING | read-only | mandatory |
| chassisDiscovery OBJECT-TYPE Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.12.2 | INTEGER {execute(1)} | read-write | mandatory |
| componentPower OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.31 | |||
| componentPowerTable OBJECT-TYPE Table of component remote power control information. Contains power on/off enablement status for each component. | 1.3.6.1.4.1.2.3.51.2.22.31.1 | not-accessible | mandatory | |
| componentPowerEntry OBJECT-TYPE Component power/restart table entry | 1.3.6.1.4.1.2.3.51.2.22.31.1.1 | not-accessible | mandatory | |
| componentPowerTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentPowerName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.2 | OCTET STRING | read-only | mandatory |
| componentPowerState OBJECT-TYPE Indicates the power state of the component specified. If the state cannot be determined, the unknown(255) is returned. | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.3 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| componentPowerAction OBJECT-TYPE Control the power state of a specific component. none: No action, value returned for GET. off: Power-off component. on: Power-on component. softoff: Shutdown OS and power-off component. This operation is not supported on all components. restart: Restart a component. restartSysMgmtProcessor: Restart a component's system management processor. restartNMI: Issue a NMI (Non-Maskable Interrupt) restart to the component. This option is not supported on all components. NOTE: Value returned for the GET command is meaningless for this MIB object. The componentPowerState MIB object should be used to check the power state of the component(s) | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.4 | INTEGER {none(0), off(1), on(2), softoff(3), restart(4), restartSysMgmtProcessor(5), restartNMI(6)} | read-write | mandatory |
| componentPowerEnableSMSBootMenu OBJECT-TYPE Enables/disables a component restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all components, and at the time of this MIB definition was only supported on POWER blades. | 1.3.6.1.4.1.2.3.51.2.22.31.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| componentPowerTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentPowerTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.31.2 | INTEGER | read-only | mandatory |
| componentPowerDetailsTable OBJECT-TYPE Table of component power detail information. | 1.3.6.1.4.1.2.3.51.2.22.31.6 | not-accessible | mandatory | |
| componentPowerDetailsEntry OBJECT-TYPE Component power Details table entry | 1.3.6.1.4.1.2.3.51.2.22.31.6.1 | not-accessible | mandatory | |
| componentPowerDetailsTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentPowerDetailsName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.2 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsMaxPowerConfig OBJECT-TYPE Component Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the component. This function is also known as power capping. Component must be powered on to set this value. If the value of maximum power config is zero, it means the component doesn't support the power capping feature | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.3 | INTEGER | read-write | mandatory |
| componentPowerDetailsEffectiveClockRate OBJECT-TYPE Component Module Details Table Effective CPU Clock Rate applies to DPM components only. It displays processor's effective clock rate based on sample interval. Note that some components do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server component spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.4 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsMaximumClockRate OBJECT-TYPE Component Module Details Table Maximum CPU Clock Rate applies to DPM components only. It displays processor's maximum clock rate based on sample interval. Note that some components do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server components spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.5 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsPowerSaverMode OBJECT-TYPE When enabled, the static low power saver mode allows the component to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsDynamicPowerSaver if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.6 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| componentPowerDetailsDynamicPowerSaver OBJECT-TYPE When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the component to be controlled based on how busy the CPU is. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsPowerSaverMode if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.7 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| componentPowerDetailsDynamicPowerFavorPerformanceOverPower OBJECT-TYPE When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the component only after Dynamic Power Saver is enabled. This feature is not available on all components types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.8 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| componentPowerDetailsPowerControl OBJECT-TYPE This object is used to get or set the power control setting on a component. If dynamic power mgmt is not supported on a component, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide component. The same can be used if the component is single wide. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.9 | INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)} | read-write | mandatory |
| componentPowerDetailsPcapMin OBJECT-TYPE Component Module Details Table power capping Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.10 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsPcapGuaranteedMin OBJECT-TYPE Component Module Details Table power capping Guaranteed Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.11 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsPcapMax OBJECT-TYPE Component Module Details Table power capping Maximum value in watts. The component must support the advanced power management feature. If the value is '<max1> Watts,<max2> Watts', which means, - if componentPowerDetailsDynamicPowerSaver is enabled, it is <max2> - otherwise it is <max1> If the value of Pcap Max is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.12 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsStaticCap OBJECT-TYPE Component Module Details Table static capabilities list. This is a list of five power management capabilities that the component may or may not support. The list of power management capabilities is as follow: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is not there, '01' indicates that the capability is present on the component. The 5 pairs represent the capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 01 00 00 00' This component has the capability of Power Management and Power Capping, but does not support the last three types. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.13 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsRuntimeCap OBJECT-TYPE Component Module Details Table run-time capabilities list. If the component supports the capability as indicated in the static capability information, the user has the ability to enable or disable that function and this table reflects that configuration. The power management capabilites for the run-time list is as follows: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is currently not available, '01' indicates that the capability is currently available. The 5 pairs represent the current capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 00 00 00 00' This component has the capability of Power Management only. The current state of the component does not support the remaining 4 capabiites at this time. | 1.3.6.1.4.1.2.3.51.2.22.31.6.1.14 | OCTET STRING | read-only | mandatory |
| componentPowerDetailsTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentPowerDetailsTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.31.7 | INTEGER | read-only | mandatory |
| componentConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.32 | |||
| componentBayDataTable OBJECT-TYPE Table of component bay User data information. Contains user provided data for each component bay. | 1.3.6.1.4.1.2.3.51.2.22.32.1 | not-accessible | mandatory | |
| componentBayDataEntry OBJECT-TYPE Component Bay Data table entry | 1.3.6.1.4.1.2.3.51.2.22.32.1.1 | not-accessible | mandatory | |
| componentBayDataTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentBayDataName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.2 | OCTET STRING | read-only | mandatory |
| componentBayDataStatus OBJECT-TYPE This shows Bay Data (BD) Status. 0 means the component fully supports BD. 1 means that the component's BIOS does not support BD. 2 means that there is no component in the bay. 3 means that the component is being discovered. 255 means that the component does not support BBD. | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.3 | INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)} | read-only | mandatory |
| componentBayData OBJECT-TYPE A null terminated string that defines the component Bay Data. This data is puched to the components's BSMP and SMBIOS structures, where it can be used by the components's OS. Up to 60 characters can be defined plus a Null terminator. | 1.3.6.1.4.1.2.3.51.2.22.32.1.1.4 | OCTET STRING (SIZE(0..60)) | read-write | mandatory |
| componentBayDataTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentBayDataTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.2 | INTEGER | read-only | mandatory |
| componentEthOverUSBInterfaceTable OBJECT-TYPE Table of blade Service Processor's Ethernet over USB interface. | 1.3.6.1.4.1.2.3.51.2.22.32.6 | not-accessible | mandatory | |
| componentEthOverUSBInterfaceEntry OBJECT-TYPE Blade Service Processor's Ethernet over USB interface entry. | 1.3.6.1.4.1.2.3.51.2.22.32.6.1 | not-accessible | mandatory | |
| componentEthOverUSBInterfaceTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentEthOverUSBInterfaceName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.2 | OCTET STRING | read-only | mandatory |
| componentEthOverUSBInterfaceEnable OBJECT-TYPE This object allows the user to view the status of, and enable or disable, a component's interface on Ethernet-over-USB. NOTE: If the component either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect. | 1.3.6.1.4.1.2.3.51.2.22.32.6.1.3 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| componentEthOverUSBInterfaceTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentEthOverUSBInterfaceTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.7 | INTEGER | read-only | mandatory |
| componentConfigurationTable OBJECT-TYPE Table of component configuration information. | 1.3.6.1.4.1.2.3.51.2.22.32.11 | not-accessible | mandatory | |
| componentConfigurationEntry OBJECT-TYPE Component configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.32.11.1 | not-accessible | mandatory | |
| componentConfigurationTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentConfigurationName OBJECT-TYPE The name of the component as a null terminated string. This object is configurable. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.2 | OCTET STRING | read-write | mandatory |
| componentConfigurationActiveBootMode OBJECT-TYPE Indicates the active copy of the firmware from which the component is booting. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.3 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-only | mandatory |
| componentConfigurationPendingBootMode OBJECT-TYPE Indicates the copy of the firmware from which the component will boot after the next reboot. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.4 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-write | mandatory |
| componentConfigurationAutoPowerOn OBJECT-TYPE Component auto-power on policy. - restore: component will be powered on which were previously on. - auto: component will automatically be powered on when power is applied to the chassis. - manual: component will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.5 | INTEGER {restore(1), auto(2), manual(3), notApplicable(255)} | read-write | mandatory |
| componentConfigurationPowerOnRestartDelay OBJECT-TYPE Restart delay (in seconds) when power is applied to a component. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.6 | INTEGER (0..32767) | read-write | mandatory |
| componentConfigurationLocalPowerControlEnable OBJECT-TYPE Component local power control enablement status. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.7 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| componentConfigurationWakeOnLanControlEnable OBJECT-TYPE Component Wake On LAN enablement status. If WOL is not supported by the component, it displays 'notApplicable' and WOL can not be enabled or disabled. | 1.3.6.1.4.1.2.3.51.2.22.32.11.1.8 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| componentConfigurationTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentConfigurationTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.12 | INTEGER | read-only | mandatory |
| componentNetworkConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.32.16 | |||
| componentIPv4ConfigTable OBJECT-TYPE Table of all components' network interfaces. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1 | not-accessible | mandatory | |
| componentIPv4ConfigEntry OBJECT-TYPE Component configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1 | not-accessible | mandatory | |
| componentIPv4ConfigTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentIPv4ConfigPortIndex OBJECT-TYPE The physical port number of the given entry. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.2 | INTEGER | read-only | mandatory |
| componentIPv4ConfigName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.3 | OCTET STRING | read-only | mandatory |
| componentIPv4ConfigPortLabel OBJECT-TYPE Show string label that identifies the interface. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.4 | OCTET STRING | read-only | mandatory |
| componentIPv4ConfigPhysicalLinkStatus OBJECT-TYPE Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.5 | INTEGER {down(0), up(1), notApplicable(255)} | read-only | mandatory |
| componentIPv4ConfigPhysicalLinkState OBJECT-TYPE Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, componentIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.6 | INTEGER {down(0), up(1), loopback(2), notApplicable(255)} | read-write | mandatory |
| componentIPv4ConfigIPAddr OBJECT-TYPE Show/modify current IP address of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.7 | IpAddress | read-write | mandatory |
| componentIPv4ConfigSubnetMask OBJECT-TYPE Show or modifie current subnet mask of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.8 | IpAddress | read-write | mandatory |
| componentIPv4ConfigGatewayAddr OBJECT-TYPE Show or modify current IP gateway of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.9 | IpAddress | read-write | mandatory |
| componentIPv4ConfigVlanId OBJECT-TYPE This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.10 | INTEGER | read-write | mandatory |
| componentIPv4ConfigDHCPEnable OBJECT-TYPE IP config method on the component network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.11 | INTEGER {useStatic(0), useDhcp(1), tryDhcpThenTryStatic(2), notApplicable(255)} | read-write | mandatory |
| componentIPv4ConfigMACAddr OBJECT-TYPE Show the component network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'. | 1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.12 | OCTET STRING | read-only | mandatory |
| componentIPv4ConfigTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentIPv4ConfigTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.16.2 | INTEGER | read-only | mandatory |
| componentIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.32.16.11 | |||
| componentIPv6ConfigTable OBJECT-TYPE A table of IPv6 configuration options for components. NOTE: This MIB object is not applicable to components that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1 | not-accessible | mandatory | |
| componentIPv6ConfigEntry OBJECT-TYPE IPv6 configuration options for a component. NOTE: This MIB object is not applicable to components that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1 | not-accessible | mandatory | |
| componentIPv6ConfigTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentIPv6ConfigPortIndex OBJECT-TYPE The physical port number of the given entry | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.2 | INTEGER | read-only | mandatory |
| componentIPv6ConfigName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.3 | OCTET STRING | read-only | mandatory |
| componentIPv6ConfigEnabled OBJECT-TYPE Enables/Disables IPv6 support on the component. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.4 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| componentIPv6ConfigStatic OBJECT-TYPE Enables/Disables IPv6 static configuration support on the component. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| componentDHCPv6ConfigEnabled OBJECT-TYPE Enables/Disables DHCPv6 address configuration support on the component. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| componentIPv6ConfigStatelessEnabled OBJECT-TYPE Enables/Disables IPv6 stateless auto-configuration support on the component. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.7 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| componentIPv6ConfigTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentIPv6ConfigTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.2 | INTEGER | read-only | mandatory |
| componentIPv6AddressTable OBJECT-TYPE A table of assigned IPv6 addresses for components. NOTE: This MIB object is not applicable to components that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6 | not-accessible | mandatory | |
| componentIPv6AddressEntry OBJECT-TYPE The assigned IPv6 address for a given component. NOTE: This MIB object is not applicable to components that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1 | not-accessible | mandatory | |
| componentIPv6AddressTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with multiple indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentIPv6AddressPortIndex OBJECT-TYPE The component's physical port number for the given entry. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.2 | INTEGER | read-only | mandatory |
| componentIPv6AddressEntryIndex OBJECT-TYPE The component's address entry index. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.3 | INTEGER | read-only | mandatory |
| componentIPv6AddressName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.4 | OCTET STRING | read-only | mandatory |
| componentIPv6AddressType OBJECT-TYPE The address type. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.5 | INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)} | read-only | mandatory |
| componentIPv6Address OBJECT-TYPE The assigned IPv6 address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.6 | InetAddressIPv6 | read-write | mandatory |
| componentIPv6AddressPrefixLen OBJECT-TYPE The prefix length for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.7 | INTEGER (1..128) | read-write | mandatory |
| componentIPv6AddressDefaultRoute OBJECT-TYPE The default route used for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.8 | InetAddressIPv6 | read-write | mandatory |
| componentIPv6AddressTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentIPv6AddressTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.16.11.7 | INTEGER | read-only | mandatory |
| componentTimeTable OBJECT-TYPE Table of Component NTP Configuration. | 1.3.6.1.4.1.2.3.51.2.22.32.20 | not-accessible | mandatory | |
| componentTimeEntry OBJECT-TYPE Component NTP Configuration entry. | 1.3.6.1.4.1.2.3.51.2.22.32.20.1 | not-accessible | mandatory | |
| componentTimeTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentTimeName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.2 | OCTET STRING | read-only | mandatory |
| componentTimeNTPEnable OBJECT-TYPE This object allows the user to view the status of, and enable or disable, a component's ability to have it's NTP information updated by the CMM. NOTE: If the component either does not exist or does not support this feature, it displays 'notApplicable'. | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.3 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| componentTimeNTPFrequency OBJECT-TYPE This object allows the user to view or set the synchronization frequency (in minutes) of the NTP information update from the CMM. NOTE: If the component either does not exist or does not support this feature, it displays '0'. | 1.3.6.1.4.1.2.3.51.2.22.32.20.1.4 | INTEGER (0..44640) | read-write | mandatory |
| componentTimeTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentTimeTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.21 | INTEGER | read-only | mandatory |
| componentSolTable OBJECT-TYPE Component Serial-over-LAN (SOL) configuration table. | 1.3.6.1.4.1.2.3.51.2.22.32.26 | not-accessible | mandatory | |
| componentSolEntry OBJECT-TYPE Component Serial-over-LAN (SOL) configuration entry. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1 | not-accessible | mandatory | |
| componentSolTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentSolName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.2 | OCTET STRING | read-only | mandatory |
| componentSolEnable OBJECT-TYPE Disable or enable the Serial-over-LAN (SOL) on a component. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.3 | INTEGER {solDisabled(0), solEnabled(1)} | read-write | mandatory |
| componentSolIpAddr OBJECT-TYPE This is deprecated in favor of componentSolIpAddr. IP address of the component derived from the IP address range for the system management processors on the component. NOTE: The IPv6 address for a component can be view with the componentIPv6AddressTable. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.4 | IpAddress | read-only | deprecated |
| componentSolSessionStatus OBJECT-TYPE Status of a Serial-over-LAN (SOL) session: solSessionNotReady: No SOL session connected to the component. solSessionReady: There is a SOL session to the component. solSessionActive: There is a SOL session to the component and there is a client using the SOL session. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.5 | INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)} | read-only | mandatory |
| componentSolCapability OBJECT-TYPE Display whether or not the component supports the Serial-over-LAN (SOL) feature. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.6 | INTEGER {notSupport(0), support(1)} | read-only | mandatory |
| componentSolIpAddr6 OBJECT-TYPE IPv6 address of the blade. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.7 | InetAddressIPv6 | read-only | mandatory |
| componentSolRetryInterval OBJECT-TYPE Retry interval time in miliseconds. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.8 | INTEGER | read-only | mandatory |
| componentSolRetryCount OBJECT-TYPE Retry count. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.9 | INTEGER | read-only | mandatory |
| componentSolBytesSent OBJECT-TYPE Number of bytes sent. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.10 | INTEGER | read-only | mandatory |
| componentSolBytesReceived OBJECT-TYPE Number of bytes received. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.11 | INTEGER | read-only | mandatory |
| componentSolDestinationMAC OBJECT-TYPE MAC address of the blade. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.12 | OCTET STRING | read-only | mandatory |
| componentSolConsoleUserId OBJECT-TYPE Sol console user name. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.13 | OCTET STRING | read-only | mandatory |
| componentSolConsoleLoginFrom OBJECT-TYPE The location information from where the SOL console is logged in. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.14 | OCTET STRING | read-only | mandatory |
| componentSolConsoleLoginStart OBJECT-TYPE The time that SOL console starts. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.15 | OCTET STRING | read-only | mandatory |
| componentSolConsoleLoginEnd OBJECT-TYPE The time that SOL console ends. | 1.3.6.1.4.1.2.3.51.2.22.32.26.1.16 | OCTET STRING | read-only | mandatory |
| componentSolTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentSolTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.32.27 | INTEGER | read-only | mandatory |
| componentMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.37 | |||
| componentSystemStatusTable OBJECT-TYPE Table of component status information. | 1.3.6.1.4.1.2.3.51.2.22.37.1 | not-accessible | mandatory | |
| componentSystemStatusEntry OBJECT-TYPE Component system status entry | 1.3.6.1.4.1.2.3.51.2.22.37.1.1 | not-accessible | mandatory | |
| componentStatusTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentStatusName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.2 | OCTET STRING | read-only | mandatory |
| componentStatusPowerState OBJECT-TYPE Indicates the power state of the component specified. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.3 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| componentStatusHealthState OBJECT-TYPE The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.4 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| componentStatusPowerEnable OBJECT-TYPE Power enable state for the component. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.5 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| componentStatusWakeOnLanEnable OBJECT-TYPE Wake on LAN enable state for the component. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.6 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-only | mandatory |
| componentStatusWidth OBJECT-TYPE The width of the component including any supplement component attached to it | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.7 | INTEGER | read-only | mandatory |
| componentStatusIOCompatibility OBJECT-TYPE I/O compatibility status for the component. The possible values and their meanings are as follows: unknown: This indicates a communication error for the component. ok: This is the normal (good) case where the component and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this component is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the component | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.21 | OCTET STRING | read-only | mandatory |
| componentStatusInventoryReady OBJECT-TYPE When a component management controller or the MM is reset, the component inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each component regarding the status of this information. Notes: For components that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.22 | INTEGER {notReady(0), ready(1)} | read-only | mandatory |
| componentStatusBootCountPowerOnTimeBoots OBJECT-TYPE Blade boot count. This is valid for blade components and otherwise is undefined. Writing this value resets the boot count to zero. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.23 | INTEGER | read-write | mandatory |
| componentStatusBootCountPowerOnTimeSecs OBJECT-TYPE Blade power on time in seconds. This is valid for blade components and otherwise is undefined. Writing this value resets the power on time to zero. | 1.3.6.1.4.1.2.3.51.2.22.37.1.1.24 | INTEGER | read-write | mandatory |
| componentSystemStatusTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentSystemStatusTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.2 | INTEGER | read-only | mandatory |
| componentHealthSummaryTable OBJECT-TYPE Table of component health summary information. Contains information about the overall component health status. Each component contains a list of critical or warning events for that component or severity of good or none if none exist. | 1.3.6.1.4.1.2.3.51.2.22.37.6 | not-accessible | mandatory | |
| componentHealthSummaryEntry OBJECT-TYPE Component health summary entry | 1.3.6.1.4.1.2.3.51.2.22.37.6.1 | not-accessible | mandatory | |
| componentHealthTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentHealthEventIndex OBJECT-TYPE An index for the critical or warning health events for a given component. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.2 | INTEGER (0..255) | read-only | mandatory |
| componentHealthSummaryName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.3 | OCTET STRING | read-only | mandatory |
| componentHealthSummarySeverity OBJECT-TYPE System health summary severity of an event for the given component. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.4 | OCTET STRING | read-only | mandatory |
| componentHealthSummaryDescription OBJECT-TYPE System health summary description of an event for the given component. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.5 | OCTET STRING | read-only | mandatory |
| componentHealthSummaryDateTime OBJECT-TYPE System health summary date time of an event for the given component. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.6 | OCTET STRING | read-only | mandatory |
| componentHealthSummaryEventID OBJECT-TYPE System health summary event ID of an event for the given component. | 1.3.6.1.4.1.2.3.51.2.22.37.6.1.7 | OCTET STRING | read-only | mandatory |
| componentHealthSummaryTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentHealthSummaryTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.7 | INTEGER | read-only | mandatory |
| componentMACAddressTable OBJECT-TYPE Table of MAC address VPD information for each component. | 1.3.6.1.4.1.2.3.51.2.22.37.11 | not-accessible | mandatory | |
| componentMACAddressEntry OBJECT-TYPE Component MAC address table entry | 1.3.6.1.4.1.2.3.51.2.22.37.11.1 | not-accessible | mandatory | |
| componentMACAddressTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentMACAddressIndex OBJECT-TYPE Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.2 | INTEGER | read-only | mandatory |
| componentMACAddressName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.3 | OCTET STRING | read-only | mandatory |
| componentMACAddress OBJECT-TYPE The MAC address VPD value for this component and index. The value is a null terminated string. For IOMs which are members of a stack, this field is not applicable and should be disregarded. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.4 | OCTET STRING | read-only | mandatory |
| componentMACAddressTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentMACAddressTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.12 | INTEGER | read-only | mandatory |
| componentUniqueIDsTable OBJECT-TYPE Table of unique ID information for each component. | 1.3.6.1.4.1.2.3.51.2.22.37.13 | not-accessible | mandatory | |
| componentUniqueIDsEntry OBJECT-TYPE Component unique ID table entry | 1.3.6.1.4.1.2.3.51.2.22.37.13.1 | not-accessible | mandatory | |
| componentUniqueIDsTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentUniqueIDsIndex OBJECT-TYPE Each component may have one or more unique ID values associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.2 | INTEGER | read-only | mandatory |
| componentUniqueIDsName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.3 | OCTET STRING | read-only | mandatory |
| componentUniqueIDsType OBJECT-TYPE Type of the unique ID in the object, componentUniqueIDsValue. The type is one of the following: World Wide Name (wwn), Global Unique IDs (guid) or Serial Attach SCSI IDs (sas). | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.4 | INTEGER {wwn(1), guid(2), sas(3)} | read-only | mandatory |
| componentUniqueIDsValue OBJECT-TYPE The unique ID value for this component and index. The value is a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.13.1.5 | OCTET STRING (SIZE(0..255)) | read-only | mandatory |
| componentUniqueIDsTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentUniqueIDsTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.14 | INTEGER | read-only | mandatory |
| componentVoltagesTable OBJECT-TYPE Table of component voltage sensor information. | 1.3.6.1.4.1.2.3.51.2.22.37.16 | not-accessible | mandatory | |
| componentVoltagesEntry OBJECT-TYPE Component voltages entry. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1 | not-accessible | mandatory | |
| componentVoltagesTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentVoltagesSensorIndex OBJECT-TYPE An index for the critical or warning health events for a given component. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.2 | INTEGER (0..255) | read-only | mandatory |
| componentVoltagesComponentName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.3 | OCTET STRING | read-only | mandatory |
| componentVoltagesSensorLabel OBJECT-TYPE The label of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.4 | OCTET STRING | read-only | mandatory |
| componentVoltagesSensorValue OBJECT-TYPE The value of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.5 | OCTET STRING | read-only | mandatory |
| componentVoltagesLowWarningThreshold OBJECT-TYPE The low warning threshold of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.6 | OCTET STRING | read-only | mandatory |
| componentVoltagesHighWarningThreshold OBJECT-TYPE The high warning threshold of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.16.1.7 | OCTET STRING | read-only | mandatory |
| componentVoltagesTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentVoltagesTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.17 | INTEGER | read-only | mandatory |
| componentTemperaturesTable OBJECT-TYPE Table of component temperature sensor information. | 1.3.6.1.4.1.2.3.51.2.22.37.21 | not-accessible | mandatory | |
| componentTemperaturesEntry OBJECT-TYPE Component temperatures entry. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1 | not-accessible | mandatory | |
| componentTemperaturesTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentTemperaturesSensorIndex OBJECT-TYPE An index for the temperature Sensors for a given component. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.2 | INTEGER (0..255) | read-only | mandatory |
| componentTemperaturesComponentName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.3 | OCTET STRING | read-only | mandatory |
| componentTemperaturesSensorLabel OBJECT-TYPE The label of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.4 | OCTET STRING | read-only | mandatory |
| componentTemperaturesSensorValue OBJECT-TYPE The value of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.5 | OCTET STRING | read-only | mandatory |
| componentTemperaturesWarningThreshold OBJECT-TYPE The warning threshold of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.6 | OCTET STRING | read-only | mandatory |
| componentTemperaturesShutdownThreshold OBJECT-TYPE The Shutdown threshold of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.7 | OCTET STRING | read-only | mandatory |
| componentTemperaturesWarningResetThreshold OBJECT-TYPE The Warning Reset threshold of the sensor as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.21.1.8 | OCTET STRING | read-only | mandatory |
| componentTemperaturesTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentTemperaturesTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.22 | INTEGER | read-only | mandatory |
| componentIOCompatibilityTable OBJECT-TYPE Table of component IO Compatibility information. | 1.3.6.1.4.1.2.3.51.2.22.37.26 | not-accessible | mandatory | |
| componentIOCompatibilityEntry OBJECT-TYPE Component IO compatibility entry. | 1.3.6.1.4.1.2.3.51.2.22.37.26.1 | not-accessible | mandatory | |
| componentIOCompatibilityTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentIOCompatibilityIOMBay OBJECT-TYPE An index for the IO Compatibility modules for a given component. | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.2 | INTEGER (0..255) | read-only | mandatory |
| componentIOCompatibilityComponentName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.3 | OCTET STRING | read-only | mandatory |
| componentIOCompatibilityIOMPower OBJECT-TYPE The power state of the module specified in componentIOCompatibilityIOMBay. n/a if module not installed. | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.4 | OCTET STRING | read-only | mandatory |
| componentIOCompatibilityIOMFabricType OBJECT-TYPE The fabric type of the module specified in componentIOCompatibilityIOMBay. | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.5 | OCTET STRING | read-only | mandatory |
| componentIOCompatibilityFabricOnComponent OBJECT-TYPE The fabric type for this channel on the original component (may be onboard fabric or an expansion card). | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.6 | OCTET STRING | read-only | mandatory |
| componentIOCompatibilityStatus OBJECT-TYPE The compatibility status between the component and the module specified in componentIOCompatibilityIOMBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the component. n/a: (Not applicable) The module specified in componentIOCompatibilityIOMBay is a bridge, so the component port cannot connect to it. Attention: The module specified in componentIOCompatibilityIOMBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in componentIOCompatibilityIOMBay is of unknown type Unknown fabric type on the component | 1.3.6.1.4.1.2.3.51.2.22.37.26.1.7 | OCTET STRING | read-only | mandatory |
| componentIOCompatibilityTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentIOCompatibilityTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.37.27 | INTEGER | read-only | mandatory |
| nodeConnectivityTable OBJECT-TYPE Table of node connectivity information. This table provides information related to the node communication status. | 1.3.6.1.4.1.2.3.51.2.22.37.31 | not-accessible | mandatory | |
| nodeConnectivityEntry OBJECT-TYPE Connectivity information for nodes. | 1.3.6.1.4.1.2.3.51.2.22.37.31.1 | not-accessible | mandatory | |
| nodeConnectivityIndex OBJECT-TYPE Node Connectivity table index. | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.1 | INTEGER (0..128) | read-only | mandatory |
| nodeConnectivityName OBJECT-TYPE The name of the node as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.2 | OCTET STRING | read-only | mandatory |
| nodeConnectivityStatus OBJECT-TYPE Indicates the communication status of the node. | 1.3.6.1.4.1.2.3.51.2.22.37.31.1.3 | INTEGER {notcommunicating(0), communicating(1)} | read-only | mandatory |
| componentServiceReset OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.38 | |||
| componentServiceResetTable OBJECT-TYPE A table providing aux power status and the ability to perform a virtual reseat or hard restart of a component. | 1.3.6.1.4.1.2.3.51.2.22.38.1 | not-accessible | mandatory | |
| componentServiceResetEntry OBJECT-TYPE Component module power service reset entry | 1.3.6.1.4.1.2.3.51.2.22.38.1.1 | not-accessible | mandatory | |
| componentServiceResetTopologyPath OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentServiceResetName OBJECT-TYPE A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.2 | OCTET STRING | read-only | mandatory |
| componentServiceResetStatus OBJECT-TYPE Status of the aux power. A value of auxPowerOff(0) indicates that the componant aux power is off. A value of auxPowerOn(1) indicates that the componant aux power is on. | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.3 | INTEGER {auxPowerOff(0), auxPowerOn(1), unknown(255)} | read-only | mandatory |
| componentServiceResetCmd OBJECT-TYPE NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See componentStatusHealthState in componentSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the processor causing it to re-initialize. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). | 1.3.6.1.4.1.2.3.51.2.22.38.1.1.4 | INTEGER {noOperation(0), resetVirtualReseatOperation(1), resetHardRestartOperation(2)} | read-write | mandatory |
| componentServiceResetTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentServiceResetTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.38.2 | INTEGER | read-only | mandatory |
| componentLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.39 | |||
| componentLEDsTable OBJECT-TYPE Table of component LED information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | 1.3.6.1.4.1.2.3.51.2.22.39.1 | not-accessible | mandatory | |
| componentLEDsEntry OBJECT-TYPE Component LEDs information entry | 1.3.6.1.4.1.2.3.51.2.22.39.1.1 | not-accessible | mandatory | |
| ledComponentTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| ledComponentName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.2 | OCTET STRING | read-only | mandatory |
| ledComponentFault OBJECT-TYPE Indicates whether the component fault LED is on or off. | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.3 | INTEGER {off(0), on(1)} | read-only | mandatory |
| ledComponentCheckLog OBJECT-TYPE Indicates whether the component check log information LED is on or off. For Write access, the LED can be turned off only. | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.4 | INTEGER {off(0), on(1)} | read-write | mandatory |
| ledComponentIdentity OBJECT-TYPE Indicates whether the component identify LED is on, off, or blinking. | 1.3.6.1.4.1.2.3.51.2.22.39.1.1.5 | INTEGER {off(0), on(1), blinking(2)} | read-write | mandatory |
| componentLEDsTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentLEDsTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.39.2 | INTEGER | read-only | mandatory |
| componentLEDsDetailsTable OBJECT-TYPE Table of LED info for each component. | 1.3.6.1.4.1.2.3.51.2.22.39.9 | not-accessible | mandatory | |
| componentLEDsDetailsEntry OBJECT-TYPE Component LED info table entry | 1.3.6.1.4.1.2.3.51.2.22.39.9.1 | not-accessible | mandatory | |
| componentLEDsDetailsTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentLEDsDetailsIndex OBJECT-TYPE Each component may have one or more LEDs and data associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.2 | INTEGER | read-only | mandatory |
| componentLEDsDetailsComponentType OBJECT-TYPE The type of the component/subcomponent grouping for this LED. | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.3 | OCTET STRING | read-only | mandatory |
| componentLEDsDetailsLabel OBJECT-TYPE The text description of the LED. | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.4 | OCTET STRING | read-only | mandatory |
| componentLEDsDetailsState OBJECT-TYPE The current state of the LED. | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.5 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| componentLEDsDetailsLocation OBJECT-TYPE The physical location of this LED on the hardware. | 1.3.6.1.4.1.2.3.51.2.22.39.9.1.6 | OCTET STRING | read-only | mandatory |
| componentLEDsDetailsTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentLEDsDetailsTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.39.10 | INTEGER | read-only | mandatory |
| backupRestore OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.42 | |||
| backupRestoreAction OBJECT-TYPE Starts the backup or restore operation. It is intended to be write-only. NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.1 | INTEGER {backup(0), restore(1), restoreAndRestart(2)} | read-write | mandatory |
| backupRestoreStatus OBJECT-TYPE Get the status of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.2 | INTEGER {ready(0), pending(1)} | read-only | mandatory |
| backupRestoreMessage OBJECT-TYPE Get the status message of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.3 | OCTET STRING | read-only | mandatory |
| backupRestoreURI OBJECT-TYPE Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/cmd.bkp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/cmd.bkp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be:<protocol>://<hostname>/<pathname>. Note:When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.4 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| backupRestorePassword OBJECT-TYPE Password used for the encryption/decryption of the sensitive data in the backup file. It is intended to be write-only. NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.5 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| backupRestoreLogURI OBJECT-TYPE Indicates the URI address where the log file will be put. It will be used only if the backupRestoreLogPush will be set on push. Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file will reside, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/restore.log where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/restore.log. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be:<protocol>://<hostname>/<pathname>. Note: When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> NOTE: This function is available only for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.6 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| backupRestoreLogPush OBJECT-TYPE Causes the restore operation to push the log to the URI address. NOTE: This can be used when restoring without restarting. NOTE: This function is only available for SNMPv3. | 1.3.6.1.4.1.2.3.51.2.22.42.7 | INTEGER {noPush(0), push(1)} | read-write | mandatory |
| service OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23 | |||
| bladeServiceData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.3 | |||
| bladeServiceDataTable OBJECT-TYPE Table of blade service data information. | 1.3.6.1.4.1.2.3.51.2.23.3.1 | not-accessible | mandatory | |
| bladeServiceDataEntry OBJECT-TYPE Blade service data entry | 1.3.6.1.4.1.2.3.51.2.23.3.1.1 | not-accessible | mandatory | |
| serviceDataIndex OBJECT-TYPE Blade service date index. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.1 | INTEGER | read-only | mandatory |
| serviceDataBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| serviceDataBladeExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| serviceDataBladePowerState OBJECT-TYPE Indicates whether the blade specified is powered on or not. If the MM is experiencing a communication problem with the blade, the state may be returned as unknown(255) | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| serviceDataBladeName OBJECT-TYPE The name of the blade as a string. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.5 | OCTET STRING | read-only | mandatory |
| serviceDataDumpInitiate OBJECT-TYPE Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.7 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| serviceDataDumpRetrieve OBJECT-TYPE Retrieve a type of service data file from blade to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.8 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| serviceDataDumpCapabilityMask OBJECT-TYPE Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the MM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.9 | OCTET STRING | read-only | mandatory |
| serviceDataDumpInProgress OBJECT-TYPE An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.10 | INTEGER {inProgress(1), notInProgress(2), unknown(255)} | read-only | mandatory |
| serviceAdvisor OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4 | |||
| autoCallHomeSetup OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.1 | |||
| acceptLicenseAgreement OBJECT-TYPE Accept Terms and Conditions of MM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If MM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed. | 1.3.6.1.4.1.2.3.51.2.23.4.1.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| serviceAdvisorEnable OBJECT-TYPE Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled. | 1.3.6.1.4.1.2.3.51.2.23.4.1.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| serviceSupportCenter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.2 | |||
| ibmSupportCenter OBJECT-TYPE The country code for the IBM Support Center. 2 character ISO country code. | 1.3.6.1.4.1.2.3.51.2.23.4.2.1 | OCTET STRING | read-write | mandatory |
| contactInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.3 | |||
| companyName OBJECT-TYPE The organization/company name of the contact person. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.1 | OCTET STRING | read-write | mandatory |
| contactName OBJECT-TYPE The name of the contact person.1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.2 | OCTET STRING | read-write | mandatory |
| phoneNumber OBJECT-TYPE The phone of the contact person. 5-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.3 | OCTET STRING | read-write | mandatory |
| emailAddress OBJECT-TYPE The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.4 | OCTET STRING | read-write | mandatory |
| address OBJECT-TYPE The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.5 | OCTET STRING | read-write | mandatory |
| city OBJECT-TYPE The city of the machine location. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.6 | OCTET STRING | read-write | mandatory |
| state OBJECT-TYPE The state of the machine location. 2-3 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.7 | OCTET STRING | read-write | mandatory |
| postalCode OBJECT-TYPE The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid. | 1.3.6.1.4.1.2.3.51.2.23.4.3.8 | OCTET STRING | read-write | mandatory |
| phoneNumberExt OBJECT-TYPE The phone number extension of the contact person. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.9 | OCTET STRING | read-write | mandatory |
| altContactName OBJECT-TYPE The name of the alternate contact person.1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.10 | OCTET STRING | read-write | mandatory |
| altPhoneNumber OBJECT-TYPE The phone of the alternate contact person. 5-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.11 | OCTET STRING | read-write | mandatory |
| altPhoneNumberExt OBJECT-TYPE The phone number extension of the alternate contact person. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.12 | OCTET STRING | read-write | mandatory |
| altEmailAddress OBJECT-TYPE The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.13 | OCTET STRING | read-write | mandatory |
| httpProxyConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.4 | |||
| httpProxyEnable OBJECT-TYPE Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the MM to IBM. HTTP Proxy is used by the MM when it is not connected to the internet directly. | 1.3.6.1.4.1.2.3.51.2.23.4.4.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| httpProxyLocation OBJECT-TYPE Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.4.2 | OCTET STRING | read-write | mandatory |
| httpProxyPort OBJECT-TYPE The port number of the HTTP Proxy. An integer value from 1 to 65535. | 1.3.6.1.4.1.2.3.51.2.23.4.4.3 | INTEGER | read-write | mandatory |
| httpProxyUserName OBJECT-TYPE User Name of the HTTP Proxy. A maximum of 30 characters string without spaces. | 1.3.6.1.4.1.2.3.51.2.23.4.4.4 | OCTET STRING | read-write | mandatory |
| httpProxyPassword OBJECT-TYPE Password of the HTTP Proxy. A maximum of 15 characters string without spaces. | 1.3.6.1.4.1.2.3.51.2.23.4.4.5 | OCTET STRING | read-write | mandatory |
| activityLogs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.5 | |||
| activityLogTable OBJECT-TYPE Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1 | not-accessible | mandatory | |
| activityLogEntry OBJECT-TYPE Activity Log table entry. Each entry has the result of the FTP/TFTP Server attempt, the event ID, event source, date and time that event occured, and a text message. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1 | not-accessible | mandatory | |
| activityLogIndex OBJECT-TYPE The Activity Log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1 | INTEGER | read-only | mandatory |
| activityLogString OBJECT-TYPE A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2 | OCTET STRING | read-only | mandatory |
| activityLogAcknowledge OBJECT-TYPE The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via FTP/TFTP Server of Service Data. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3 | INTEGER {no(0), yes(1)} | read-write | mandatory |
| activityLogAttribute OBJECT-TYPE A string of data detailing one Activity Log entry's attribute. Status PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to FTP/TFTP Server. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The event ID, event source , date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4 | OCTET STRING | read-only | mandatory |
| autoFTPSetup OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.5 | |||
| autoFTPCallMode OBJECT-TYPE This field specifies the automated problem reporting mode. Automated problem reporting mode allows the MM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component. | 1.3.6.1.4.1.2.3.51.2.23.5.1 | INTEGER {disabled(0), ftp(1), tftp(2)} | read-write | mandatory |
| autoFTPCallAddr OBJECT-TYPE This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address. | 1.3.6.1.4.1.2.3.51.2.23.5.2 | OCTET STRING | read-write | mandatory |
| autoFTPCallPort OBJECT-TYPE This field specifies the port on remote FTP/TFTP server for data transmission. | 1.3.6.1.4.1.2.3.51.2.23.5.3 | INTEGER | read-write | mandatory |
| autoFTPCallUserID OBJECT-TYPE This field specifies the user account to login remote FTP server. | 1.3.6.1.4.1.2.3.51.2.23.5.4 | OCTET STRING | read-write | mandatory |
| autoFTPCallPassword OBJECT-TYPE This field specifies the password to login remote FTP server. | 1.3.6.1.4.1.2.3.51.2.23.5.5 | OCTET STRING | read-write | mandatory |
| callHomeExclusionEvents OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.6 | |||
| readCallHomeExclusionEventTable OBJECT-TYPE Table of Call Home Exclusion Event entries information. | 1.3.6.1.4.1.2.3.51.2.23.6.1 | not-accessible | mandatory | |
| readCallHomeExclusionEventEntry OBJECT-TYPE Call Home Exclusion Event table entry | 1.3.6.1.4.1.2.3.51.2.23.6.1.1 | not-accessible | mandatory | |
| readCallHomeExclusionEventIndex OBJECT-TYPE The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.1 | INTEGER | read-only | mandatory |
| readCallHomeExclusionEventID OBJECT-TYPE The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.2 | OCTET STRING | read-only | mandatory |
| addCallHomeExclusionEvent OBJECT-TYPE Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An Event can not be added into the exclusion list if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.2 | OCTET STRING | read-write | mandatory |
| rmCallHomeExclusionEvent OBJECT-TYPE Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An event on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.3 | OCTET STRING | read-write | mandatory |
| rmAllCallHomeExclusionEvent OBJECT-TYPE Remove all Event IDs from the Call Home Exclusion List. Events on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.4 | INTEGER {execute(1)} | read-write | mandatory |
| componentPowerServiceReset OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.10 | |||
| bladePowerServiceResetTable OBJECT-TYPE A table providing aux power status and the ability to perform a virtual reseat or hard restart of a blade. | 1.3.6.1.4.1.2.3.51.2.23.10.1 | not-accessible | mandatory | |
| bladePowerServiceResetEntry OBJECT-TYPE Blade power service reset entry | 1.3.6.1.4.1.2.3.51.2.23.10.1.1 | not-accessible | mandatory | |
| bladePowerServiceResetIndex OBJECT-TYPE Blade power service reset index. | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.1 | INTEGER | read-only | mandatory |
| bladePowerServiceResetBladeId OBJECT-TYPE The numeric blade slot number. | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladePowerServiceResetStatus OBJECT-TYPE Status of the aux power. A value of auxPowerOff(0) indicates that the blade aux power is off. A value of auxPowerOn(1) indicates that the blade aux power is on. | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.3 | INTEGER {auxPowerOff(0), auxPowerOn(1)} | read-only | mandatory |
| bladePowerServiceResetCmd OBJECT-TYPE NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See bladeHealthState in bladeSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a blade component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the blade and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the blade component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). | 1.3.6.1.4.1.2.3.51.2.23.10.1.1.4 | INTEGER {noOperation(0), resetVirtualReseatOperation(1), resetHardRestartOperation(2)} | read-write | mandatory |
| smPowerServiceResetTable OBJECT-TYPE A table providing aux power status and the ability to perform a virtual reseat or hard restart of a switch. | 1.3.6.1.4.1.2.3.51.2.23.10.2 | not-accessible | mandatory | |
| smPowerServiceResetEntry OBJECT-TYPE Switch module power service reset entry | 1.3.6.1.4.1.2.3.51.2.23.10.2.1 | not-accessible | mandatory | |
| smPowerServiceResetIndex OBJECT-TYPE Switch module power service reset index. | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.1 | INTEGER | read-only | mandatory |
| smPowerServiceResetSwitchId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.2 | INTEGER {switch1(1), switch2(2), switch3(3), switch4(4)} | read-only | mandatory |
| smPowerServiceResetStatus OBJECT-TYPE Status of the aux power power. A value of auxPowerOff(0) indicates that the switch aux power is off. A value of auxPowerOn(1) indicates that the switch aux power is on. | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.3 | INTEGER {auxPowerOff(0), auxPowerOn(1)} | read-only | mandatory |
| smPowerServiceResetCmd OBJECT-TYPE To reset the auxiliary power on a switch component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the switch and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For IOMs, the power state will be on after the operation completes. To perform a hard restart on the switch component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0). | 1.3.6.1.4.1.2.3.51.2.23.10.2.1.4 | INTEGER {noOperation(0), resetVirtualReseatOperation(1)} | read-write | mandatory |
| componentServiceData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.15 | |||
| componentServiceDataTable OBJECT-TYPE Table of component service data information. | 1.3.6.1.4.1.2.3.51.2.23.15.1 | not-accessible | mandatory | |
| componentServiceDataEntry OBJECT-TYPE Component service data entry | 1.3.6.1.4.1.2.3.51.2.23.15.1.1 | not-accessible | mandatory | |
| componentServiceDataTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentServiceDataComponentName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.2 | OCTET STRING | read-only | mandatory |
| componentServiceDataDumpInitiate OBJECT-TYPE Initiates a type of dump collection to be initiated for the component and sent to the MM. NOTE: Not all components support this, please check componentServiceDataDumpCapabilityMask OID to see if the action is supported on this component. For switch modules the serviceData(4) is the only available value that can be set. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.3 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| componentServiceDataDumpRetrieve OBJECT-TYPE Retrieve a type of service data file from component to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the componentServiceDataDumpCapabilityMask OID. NOTE: This OID is not used for switch modules. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.4 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| componentServiceDataDumpCapabilityMask OBJECT-TYPE Indicates whether the component has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the component. The values and meanings are as follows: 0000 0000 means this component does not support any at all. 0000 0001 means this component supports 'processor' type and the file remains on the component. 0000 0010 means this component supports 'platform' type and the file remains on the component. 0000 0100 means this component supports 'partition' type and the file remians on the component. 0000 1000 means this component supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this component supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this component supports 'partition' type and the file can be transferred to the MM 0100 0000 means this component supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this component supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.5 | OCTET STRING | read-only | mandatory |
| componentServiceDataDumpInProgress OBJECT-TYPE An indicator as to whether a component dump is in progress for the specified component. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the componentServiceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the component indicating 'init dump' and will be cleared upon receiving the valid dump file from the component or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.6 | INTEGER {inProgress(1), notInProgress(2), unknown(255)} | read-only | mandatory |
| componentServiceDataStatus OBJECT-TYPE A status indicator for dump progress. This object ONLY applies to switch modules dumps. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.7 | INTEGER | read-only | mandatory |
| componentServiceDataStatusDetails OBJECT-TYPE The failure status as a null terminated string. This object ONLY applies to switch modules dumps. | 1.3.6.1.4.1.2.3.51.2.23.15.1.1.8 | OCTET STRING | read-only | mandatory |
| componentServiceDataTableCacheTimeout OBJECT-TYPE The timeout value (in seconds) of the cached data for the table, componentServiceDataTable. This value is static (constant) and cannot be set. | 1.3.6.1.4.1.2.3.51.2.23.15.2 | INTEGER | read-only | mandatory |
| downloadMMServiceData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.21 | |||
| downloadMMServiceDataFileCreateAndDownload OBJECT-TYPE Specifying this string initiates the generation of the FFDC (First-Failure Data Capture) data collection (compressed group of files) for the CMM and the download of this file to the specified destination. The destination is a string of chars that specifies the remote location of service data to be saved. Use one of the following protocols: sftp, tftp, ftp, http or https. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> Note: It is recommended that the saved-data filename have an extension of .tgz to allow support personnel to identify the file. Reading this string will always return 'Not readable' since this string may contain a password. | 1.3.6.1.4.1.2.3.51.2.23.21.1 | OCTET STRING (SIZE(0..512)) | read-write | mandatory |
| downloadMMServiceDataStatus OBJECT-TYPE An indicator as to whether the FFDC generation and download is in progress. To initiate this process, set the object, downloadMMServiceDataFileCreateAndDownload (see the object's description for details). | 1.3.6.1.4.1.2.3.51.2.23.21.2 | INTEGER {ready(0), fileGenerationInProgress(1), fileDownloadInProgress(2), cancelingDownload(3)} | read-only | mandatory |
| downloadMMServiceDataResult OBJECT-TYPE An indicator as to whether the FFDC generation and download was successful. The FFDC generation and download is started by setting a destination filename with the object, downloadMMServiceDataFileCreateAndDownload. If the FFDC file generation and download process completes successfully, this object is set to complete(5). If the process encounters an error, this object is set to either: permissionFailed(1), fileGenerationFailed(2) or fileDownloadFailed(3). If the process is canceled by the user, this object will be set to canceled(4). A value of none(0) is the default value. This object may be set to none(0) if the object, downloadMMServiceDataStatus, has a value of ready(0). Setting this object to any value other than none(0) will report an error. | 1.3.6.1.4.1.2.3.51.2.23.21.3 | INTEGER {none(0), permissionFailed(1), fileGenerationFailed(2), fileDownloadFailed(3), canceled(4), complete(5)} | read-write | mandatory |
| downloadMMServiceDataCancelDownload OBJECT-TYPE Set this object to 'cancel(1)' to stop the FFDC file download process. 'cancel(1)' is the only valid value that may be set. The value of this object will be 'cancel(1)' if an user has set this value and an active FFDC download is in progress. After the process has been canceled, this object will automatically be set to 'none(0)'. | 1.3.6.1.4.1.2.3.51.2.23.21.4 | INTEGER {none(0), cancel(1)} | read-write | mandatory |
| scaling OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.24 | |||
| scalableComplexTable OBJECT-TYPE Table of scalable complex information. This table provides information related to the scalable complexes installed in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.1 | not-accessible | mandatory | |
| scalableComplexEntry OBJECT-TYPE Scalable complex information. | 1.3.6.1.4.1.2.3.51.2.24.1.1 | not-accessible | mandatory | |
| scalableComplexTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module | 1.3.6.1.4.1.2.3.51.2.24.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| scalableComplexIdentifier OBJECT-TYPE The unique numeric identifier for a complex installed in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.1.1.2 | INTEGER | read-only | mandatory |
| scalableComplexNodeName OBJECT-TYPE The name of the node as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.24.1.1.3 | OCTET STRING | read-only | mandatory |
| scalableComplexNodeHealthState OBJECT-TYPE The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component. Maintenance Mode: Node is undergoing a service operation and should not be updated or powered on/off. Firehose Dump: Node is undergoing a storage save operation and should not be udpated or powered on/off | 1.3.6.1.4.1.2.3.51.2.24.1.1.4 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)} | read-only | mandatory |
| scalableComplexNodePowerState OBJECT-TYPE Indicates the power state of the node. | 1.3.6.1.4.1.2.3.51.2.24.1.1.5 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| scalableComplexNodeResources OBJECT-TYPE A string providing a summary overview of the resources provided by this node. | 1.3.6.1.4.1.2.3.51.2.24.1.1.6 | OCTET STRING | read-only | mandatory |