MIBs Depot

CME-MIB

Registered at
1.3.6.1.4.1.2.3.51.2.2.1.9
1.3.6.1.4.1.2.3.51.2.2.30
1.3.6.1.4.1.2.3.51.2.4.3.5
1.3.6.1.4.1.2.3.51.2.22.12
1.3.6.1.4.1.2.3.51.2.22.31
1.3.6.1.4.1.2.3.51.2.22.32
1.3.6.1.4.1.2.3.51.2.22.38
1.3.6.1.4.1.2.3.51.2.22.39
1.3.6.1.4.1.2.3.51.2.22.42
1.3.6.1.4.1.2.3.51.2.23.10
1.3.6.1.4.1.2.3.51.2.23.15
1.3.6.1.4.1.2.3.51.2.23.21
Namespace
ibm
Source file
CME-MIB
Digest
sha256:b1eddaa9cb18280d777c78131de6c70fa27895401f43b896ace297457966ac2f

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CME-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
EntryStatus
type
InetAddressIPv6
TEXTUAL-CONVENTION
Represents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6
current

Objects

NameOIDSyntaxAccessStatus
ibm
OBJECT-IDENTITY
1.3.6.1.4.1.2
ibmAgents
OBJECT-IDENTITY
1.3.6.1.4.1.2.3
netfinitySupportProcessorAgent
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51
bladeCenterSnmpMIB
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2
monitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2
temperature
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1
internalTemp
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1.1
cmmTemp
OBJECT-TYPE
This field is deprecated. The return value of this field is the same as rearLEDCardTemp. Chassis management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.1.2OCTET STRINGread-onlydeprecated
ambientTemp
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1.5
rearLEDCardTempAvg
OBJECT-TYPE
The average rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.5.1OCTET STRINGread-onlymandatory
rearLEDCardTempMin
OBJECT-TYPE
The minimum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.5.2OCTET STRINGread-onlymandatory
rearLEDCardTempMax
OBJECT-TYPE
The maximum rear LED card temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.5.3OCTET STRINGread-onlymandatory
monitorTemp
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1.9
hotAirRecircMonitoring
OBJECT-TYPE
If this is enabled, the management module will monitor for Hot Air Recirculation by detecting non-uniform air temperature(s) that may be entering the front of the chassis. This could be due to either localized hot or cold air reaching at least one of the node's or chassis temperature sensors and it exceeding the acceptable range. When enabled, this monitor will generate an event and be transmitted to any configured remote alert recipient.
1.3.6.1.4.1.2.3.51.2.2.1.9.3INTEGER {disable(0), enable(1)}read-writemandatory
hotAirRecircTempDeltaThresh
OBJECT-TYPE
This object is used to read or change the temperature delta threshold for Hot Air Recirculation detection. Values are enforced to be in the inclusive range between 5.00C and 9.00C and are specified as hundreths of a degree. For example, a value of 659 would equate to a threshold of 6.59 degrees C.
1.3.6.1.4.1.2.3.51.2.2.1.9.5INTEGERread-writemandatory
hotAirRecircStatusTable
OBJECT-TYPE
Table of hot air recirculation status information.
1.3.6.1.4.1.2.3.51.2.2.1.9.7not-accessiblemandatory
hotAirRecircStatusEntry
OBJECT-TYPE
Hot air recirculation status entry
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1not-accessiblemandatory
hotAirRecircStatusTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.2OCTET STRING (SIZE(0..100))read-onlymandatory
hotAirRecircStatusIndex
OBJECT-TYPE
Each component may have one or more sensor associated with it, this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.3INTEGERread-onlymandatory
hotAirRecircStatusName
OBJECT-TYPE
The name of the component as a null terminated string
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.4OCTET STRINGread-onlymandatory
hotAirRecircStatusSensorLabel
OBJECT-TYPE
The text label of the sensor as a null terminated string
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.5OCTET STRINGread-onlymandatory
hotAirRecircStatusSensorReading
OBJECT-TYPE
Ambient temperature reading for this component in degrees centigrade(C). The string is formatted as 'dd.dd Centigrade'.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.6OCTET STRINGread-onlymandatory
hotAirRecircStatusExceeded
OBJECT-TYPE
Indicates whether this component has exceeded the threshold of the acceptable temperature being monitored for hot air recirculation.
1.3.6.1.4.1.2.3.51.2.2.1.9.7.1.7INTEGER {no(0), yes(1)}read-onlymandatory
chassisFans
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.3
chassisFansTable
OBJECT-TYPE
Table of chassis Fan information.
1.3.6.1.4.1.2.3.51.2.2.3.50not-accessiblemandatory
chassisFansEntry
OBJECT-TYPE
Chassis Fan information entry
1.3.6.1.4.1.2.3.51.2.2.3.50.1not-accessiblemandatory
chassisFanIndex
OBJECT-TYPE
Chassis Fans table index.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.1INTEGER (0..128)read-onlymandatory
chassisFanId
OBJECT-TYPE
The numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.2INTEGER {chassisfan1(1), chassisfan2(2), chassisfan3(3), chassisfan4(4), chassisfan5(5), chassisfan6(6), chassisfan7(7), chassisfan8(8), chassisfan9(9), chassisfan10(10)}read-onlymandatory
chassisFanSpeed
OBJECT-TYPE
Chassis fan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.3OCTET STRINGread-onlymandatory
chassisFanState
OBJECT-TYPE
The health state for the chassis fan. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical
1.3.6.1.4.1.2.3.51.2.2.3.50.1.4INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
chassisFanSpeedRPM
OBJECT-TYPE
Chassis fan speed expressed in RPM. If the chassis fan is determined not to be running or the chassis fan speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.5OCTET STRINGread-onlymandatory
chassisFanControllerState
OBJECT-TYPE
The controller health state for the chassis fan.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.6INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
chassisFanCoolingZone
OBJECT-TYPE
The cooling zone for the chassis fan.
1.3.6.1.4.1.2.3.51.2.2.3.50.1.7INTEGER {unknown(0), coolingZone1(1), coolingZone2(2), coolingZone3(3), coolingZone4(4)}read-onlymandatory
chassisCoolingZoneTable
OBJECT-TYPE
Table of chassis cooling zone information.
1.3.6.1.4.1.2.3.51.2.2.3.51not-accessiblemandatory
chassisCoolingZoneEntry
OBJECT-TYPE
Chassis cooling zone information entry
1.3.6.1.4.1.2.3.51.2.2.3.51.1not-accessiblemandatory
chassisCoolingIndex
OBJECT-TYPE
Chassis Cooling Zones table index.
1.3.6.1.4.1.2.3.51.2.2.3.51.1.1INTEGER (0..128)read-onlymandatory
chassisCoolingZone
OBJECT-TYPE
The cooling zone for the chassis component.
1.3.6.1.4.1.2.3.51.2.2.3.51.1.2INTEGER {coolingZone1(1), coolingZone2(2), coolingZone3(3), coolingZone4(4)}read-onlymandatory
chassisCoolingZoneStatus
OBJECT-TYPE
The health state of the chassis cooling zone. Note: This is the health of the cooling zone, not the health status of the component in chassisCoolingZoneComponent. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical
1.3.6.1.4.1.2.3.51.2.2.3.51.1.3INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
chassisCoolingZoneComponent
OBJECT-TYPE
A component within a cooling zone.
1.3.6.1.4.1.2.3.51.2.2.3.51.1.4INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14), switchModule1(41), switchModule2(42), switchModule3(43), switchModule4(44), mgmtModule1(61), mgmtModule2(62), fan1(81), fan2(82), fan3(83), fan4(84), fan5(85), fan6(86), fan7(87), fan8(88), fan9(89), fan10(90)}read-onlymandatory
powerModuleHealth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.4
powerModuleHealthTable
OBJECT-TYPE
Table of power module health information. Contains the power health information for each power module.
1.3.6.1.4.1.2.3.51.2.2.4.1not-accessiblemandatory
powerModuleHealthEntry
OBJECT-TYPE
Power Module health entry
1.3.6.1.4.1.2.3.51.2.2.4.1.1not-accessiblemandatory
powerModuleIndex
OBJECT-TYPE
Power module index.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.1INTEGERread-onlymandatory
powerModuleExists
OBJECT-TYPE
Indicates whether the power module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.2INTEGER {false(0), true(1)}read-onlymandatory
powerModuleState
OBJECT-TYPE
The health state for the power module. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical
1.3.6.1.4.1.2.3.51.2.2.4.1.1.3INTEGER {unknown(0), good(1), warning(2), notAvailable(3), critical(4)}read-onlymandatory
powerModuleDetails
OBJECT-TYPE
The details for this power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.4OCTET STRINGread-onlymandatory
powerModuleDescription
OBJECT-TYPE
The description for this power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.9OCTET STRINGread-onlymandatory
spStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5
mmBistAndChassisStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5.2
bistRtc
OBJECT-TYPE
MM BIST Real Time Clock test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.5INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistLocalI2CBus
OBJECT-TYPE
MM BIST Local I2C bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.7INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistPrimaryMainAppFlashImage
OBJECT-TYPE
MM BIST Primary Main Application Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.8INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistSecondaryMainAppFlashImage
OBJECT-TYPE
MM BIST Secondary Main Application test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.9INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistBootRomFlashImage
OBJECT-TYPE
MM BIST Boot Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.10INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistEthernetPort1
OBJECT-TYPE
MM BIST external eth0 ethernet port test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.11INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistExternalI2CDevices
OBJECT-TYPE
MM BIST external I2C devices test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.14INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistInternalEthernetSwitch
OBJECT-TYPE
MM BIST internal external switch test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.19INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistPrimaryKernel
OBJECT-TYPE
MM BIST primary kernel test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.25INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistSecondaryKernel
OBJECT-TYPE
MM BIST secondary kernel test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.26INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistBladesInstalled
OBJECT-TYPE
The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.33OCTET STRINGread-onlymandatory
bistBladesCommunicating
OBJECT-TYPE
The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.49OCTET STRINGread-onlymandatory
bistChassisFansInstalled
OBJECT-TYPE
The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.2.5.2.65OCTET STRINGread-onlymandatory
bistChassisFansFunctional
OBJECT-TYPE
The chassis fans installed on the chassis that are functional. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If one is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.2.5.2.73OCTET STRINGread-onlymandatory
bistRearLEDCardInstalled
OBJECT-TYPE
Indicates whether a rear LED card is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.74INTEGER {no(0), yes(1)}read-onlymandatory
bistRearLEDCardCommunicating
OBJECT-TYPE
Indicates whether a rear LED card is communicating
1.3.6.1.4.1.2.3.51.2.2.5.2.75INTEGER {no(0), yes(1)}read-onlymandatory
bistOtherMMInstalled
OBJECT-TYPE
Indicates whether a redundant MM is installed.
1.3.6.1.4.1.2.3.51.2.2.5.2.76INTEGER {no(0), yes(1)}read-onlymandatory
bistOtherMMCommunicating
OBJECT-TYPE
Indicates whether a redundant MM is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.77INTEGER {no(0), yes(1)}read-onlymandatory
bistPowerModulesInstalled
OBJECT-TYPE
The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.81OCTET STRINGread-onlymandatory
bistPowerModulesFunctional
OBJECT-TYPE
The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.89OCTET STRINGread-onlymandatory
bistSwitchModulesInstalled
OBJECT-TYPE
The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'.
1.3.6.1.4.1.2.3.51.2.2.5.2.97OCTET STRINGread-onlymandatory
bistSwitchModulesCommunicating
OBJECT-TYPE
The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'.
1.3.6.1.4.1.2.3.51.2.2.5.2.113OCTET STRINGread-onlymandatory
bistChassisFansMUXAInstalled
OBJECT-TYPE
Indicates whether chassis fan MUX A is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.120INTEGER {no(0), yes(1)}read-onlymandatory
bistChassisFansMUXAFunctional
OBJECT-TYPE
Indicates whether chassis fan MUX A is functional
1.3.6.1.4.1.2.3.51.2.2.5.2.121INTEGER {no(0), yes(1)}read-onlymandatory
bistChassisFansMUXBInstalled
OBJECT-TYPE
Indicates whether chassis fan MUX B is installed
1.3.6.1.4.1.2.3.51.2.2.5.2.122INTEGER {no(0), yes(1)}read-onlymandatory
bistChassisFansMUXBFunctional
OBJECT-TYPE
Indicates whether chassis fan MUX B is functional
1.3.6.1.4.1.2.3.51.2.2.5.2.123INTEGER {no(0), yes(1)}read-onlymandatory
bistLastUpdate
OBJECT-TYPE
It is the time when the primary MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.2.200OCTET STRINGread-onlymandatory
rmmBistAndChassisStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5.3
rbistRtc
OBJECT-TYPE
Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.5INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistLocalI2CBus
OBJECT-TYPE
Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.7INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistEthernetPort1
OBJECT-TYPE
Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.11INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistExternalI2CDevices
OBJECT-TYPE
Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.14INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistInternalEthernetSwitch
OBJECT-TYPE
Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.19INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistBladesInstalled
OBJECT-TYPE
The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.33OCTET STRINGread-onlymandatory
rbistBladesCommunicating
OBJECT-TYPE
The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.49OCTET STRINGread-onlymandatory
rbistChassisFansInstalled
OBJECT-TYPE
The chassis fans that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of chassis fans supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.2.5.3.65OCTET STRINGread-onlymandatory
rbistChassisFansFunctional
OBJECT-TYPE
The chassis fans installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number supported. If it is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if one is installed and functional only in bay 1, and 2 are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.2.5.3.73OCTET STRINGread-onlymandatory
rbistRearLEDCardInstalled
OBJECT-TYPE
Indicates whether a rear LED card is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.74INTEGER {no(0), yes(1)}read-onlymandatory
rbistRearLEDCardCommunicating
OBJECT-TYPE
Indicates whether a rear LED card is communicating
1.3.6.1.4.1.2.3.51.2.2.5.3.75INTEGER {no(0), yes(1)}read-onlymandatory
rbistOtherMMInstalled
OBJECT-TYPE
Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.76INTEGER {no(0), yes(1)}read-onlymandatory
rbistOtherMMCommunicating
OBJECT-TYPE
Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'.
1.3.6.1.4.1.2.3.51.2.2.5.3.77INTEGER {no(0), yes(1)}read-onlymandatory
rbistPowerModulesInstalled
OBJECT-TYPE
The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.81OCTET STRINGread-onlymandatory
rbistPowerModulesFunctional
OBJECT-TYPE
The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.89OCTET STRINGread-onlymandatory
rbistSwitchModulesInstalled
OBJECT-TYPE
The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'.
1.3.6.1.4.1.2.3.51.2.2.5.3.97OCTET STRINGread-onlymandatory
rbistSwitchModulesCommunicating
OBJECT-TYPE
The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011'.
1.3.6.1.4.1.2.3.51.2.2.5.3.113OCTET STRINGread-onlymandatory
rbistChassisFansMUXAInstalled
OBJECT-TYPE
Indicates whether chassis fan MUX A is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.120INTEGER {no(0), yes(1)}read-onlymandatory
rbistChassisFansMUXAFunctional
OBJECT-TYPE
Indicates whether chassis fan MUX A is functional
1.3.6.1.4.1.2.3.51.2.2.5.3.121INTEGER {no(0), yes(1)}read-onlymandatory
rbistChassisFansMUXBInstalled
OBJECT-TYPE
Indicates whether chassis fan MUX B is installed
1.3.6.1.4.1.2.3.51.2.2.5.3.122INTEGER {no(0), yes(1)}read-onlymandatory
rbistChassisFansMUXBFunctional
OBJECT-TYPE
Indicates whether chassis fan MUX B is functional
1.3.6.1.4.1.2.3.51.2.2.5.3.123INTEGER {no(0), yes(1)}read-onlymandatory
rbistUpdateTime
OBJECT-TYPE
It is the time when the standby MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3.200OCTET STRINGread-onlymandatory
rbistLastUpdatePrimary
OBJECT-TYPE
It is the time when the standby MM updated the last BIST results when it was still primary.
1.3.6.1.4.1.2.3.51.2.2.5.3.201OCTET STRINGread-onlymandatory
fanPack
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.6
fanPackTable
OBJECT-TYPE
Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.6.1not-accessiblemandatory
fanPackEntry
OBJECT-TYPE
Fan Pack entry
1.3.6.1.4.1.2.3.51.2.2.6.1.1not-accessiblemandatory
fanPackIndex
OBJECT-TYPE
Fan Pack sequence index.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.1INTEGERread-onlymandatory
fanPackExists
OBJECT-TYPE
Indicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.2INTEGER {false(0), true(1)}read-onlymandatory
fanPackState
OBJECT-TYPE
The health state for the fan pack. Note that the other UIs may use slightly different terminology for the three health state values, as such: WEB - Normal, Attention, Critical CLI - OK, Non-critical, Critical
1.3.6.1.4.1.2.3.51.2.2.6.1.1.3INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
fanPackFanCount
OBJECT-TYPE
The number of fans in the fan pack.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.4INTEGER {unknown(255)}read-onlymandatory
fanPackAverageSpeed
OBJECT-TYPE
The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.5OCTET STRINGread-onlymandatory
fanPackAverageSpeedRPM
OBJECT-TYPE
The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.6OCTET STRINGread-onlymandatory
fanPackControllerState
OBJECT-TYPE
The health state for the controller for the fan pack.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.7INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
systemHealth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.7
systemHealthStat
OBJECT-TYPE
Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally.
1.3.6.1.4.1.2.3.51.2.2.7.1INTEGER {critical(0), nonCritical(2), systemLevel(4), normal(255)}read-onlymandatory
systemHealthSummaryTable
OBJECT-TYPE
Table of System Health summary. Contains more detailed information about the reasons for the overall system health status.
1.3.6.1.4.1.2.3.51.2.2.7.2not-accessiblemandatory
systemHealthSummaryEntry
OBJECT-TYPE
System Health Summary entry
1.3.6.1.4.1.2.3.51.2.2.7.2.1not-accessiblemandatory
systemHealthSummaryIndex
OBJECT-TYPE
System health summary index.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.1INTEGERread-onlymandatory
systemHealthSummarySeverity
OBJECT-TYPE
System health summary severity.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.2OCTET STRINGread-onlymandatory
systemHealthSummaryDescription
OBJECT-TYPE
System health summary description.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.3OCTET STRINGread-onlymandatory
systemHealthSummaryDateTime
OBJECT-TYPE
System health summary date time.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.4OCTET STRINGread-onlymandatory
systemHealthSummaryAuxData
OBJECT-TYPE
System health summary auxilliary event data. If auxilliary event data is available, it is device-specific event data provided to the CMM by the device.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.11OCTET STRINGread-onlymandatory
systemHealthSummaryEventID
OBJECT-TYPE
System health summary event ID.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.12OCTET STRINGread-onlymandatory
leds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8
frontPanelLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.1
faultLED
OBJECT-TYPE
Indicates whether the front panel system error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.1.1INTEGER {off(0), on(1)}read-onlymandatory
checkLogLED
OBJECT-TYPE
Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.1.2INTEGER {off(0), on(1)}read-writemandatory
identifyLED
OBJECT-TYPE
Indicates whether the front panel identity LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.1.4INTEGER {off(0), on(1), blinking(2), notAvailable(3)}read-writemandatory
bladeLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.2
bladeLEDsTable
OBJECT-TYPE
Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more.
1.3.6.1.4.1.2.3.51.2.2.8.2.1not-accessiblemandatory
bladeLEDsEntry
OBJECT-TYPE
Blade system status entry
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1not-accessiblemandatory
ledBladeIndex
OBJECT-TYPE
Blade LED table index.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1INTEGERread-onlymandatory
ledBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
ledBladeExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
ledBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
ledBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6OCTET STRINGread-onlymandatory
ledBladeFault
OBJECT-TYPE
Indicates whether the blade fault LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7INTEGER {off(0), on(1)}read-onlymandatory
ledBladeCheckLog
OBJECT-TYPE
Indicates whether the blade check log information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8INTEGER {off(0), on(1)}read-writemandatory
ledBladeIdentify
OBJECT-TYPE
Indicates whether the blade identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11INTEGER {off(0), on(1), blinking(2)}read-writemandatory
bladeLEDsDetailsTable
OBJECT-TYPE
Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more.
1.3.6.1.4.1.2.3.51.2.2.8.2.2not-accessiblemandatory
bladeLEDsDetailsEntry
OBJECT-TYPE
Blade LEDs Details entry
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1not-accessiblemandatory
ledIndex
OBJECT-TYPE
The LED index number.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1INTEGERread-onlymandatory
ledBladeBayNumber
OBJECT-TYPE
The bay number of the main server blade that the LED is grouped into.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2OCTET STRINGread-onlymandatory
ledBladeComponentType
OBJECT-TYPE
Type of the component/subcomponent grouping for this LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3OCTET STRINGread-onlymandatory
ledBladeLabel
OBJECT-TYPE
Text label for a LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4OCTET STRINGread-onlymandatory
ledBladeState
OBJECT-TYPE
Text description which denotes color or on/off/blink state for a LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
ledBladeLocation
OBJECT-TYPE
Location of this LED.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6OCTET STRINGread-onlymandatory
smLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.4
smLEDsTable
OBJECT-TYPE
Table of switch module LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.4.2not-accessiblemandatory
smLEDsEntry
OBJECT-TYPE
Switch module LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1not-accessiblemandatory
ledSMIndex
OBJECT-TYPE
Switch module LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.1INTEGERread-onlymandatory
ledSMSlot
OBJECT-TYPE
The bay number of the switch.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.2INTEGER (0..128)read-onlymandatory
ledSMLabel
OBJECT-TYPE
The name associated with the LED.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.3OCTET STRING (SIZE(256))read-onlymandatory
ledSMState
OBJECT-TYPE
NOTE: This table entry is read-write ONLY when Label = 'Enclosure Identity'. All other Label values have read-only access.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.4INTEGER {off(0), on(1), blinking(2)}read-writemandatory
ledSMLocation
OBJECT-TYPE
The physical location where the LED can be found on the Switch.
1.3.6.1.4.1.2.3.51.2.2.8.4.2.1.5OCTET STRING (SIZE(256))read-onlymandatory
chassisFanLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.5
chassisFanLEDsTable
OBJECT-TYPE
Table of chassis fan LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.5.1not-accessiblemandatory
chassisFanLEDsEntry
OBJECT-TYPE
Chassis fan LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1not-accessiblemandatory
ledChassisFanIndex
OBJECT-TYPE
Chassis fan LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1INTEGER (0..128)read-onlymandatory
ledChassisFanId
OBJECT-TYPE
The numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2INTEGER {chassisfan1(1), chassisfan2(2), chassisfan3(3), chassisfan4(4), chassisfan5(5), chassisfan6(6), chassisfan7(7), chassisfan8(8), chassisfan9(9), chassisfan10(10)}read-onlymandatory
ledChassisFanExists
OBJECT-TYPE
Indicates whether the chassis fan specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledChassisFanError
OBJECT-TYPE
Indicates whether the chassis fan error LED is on, off, or not available.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4INTEGER {off(0), on(1), notAvailable(2)}read-onlymandatory
fanPackLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.6
fanPackLEDsTable
OBJECT-TYPE
Table of fan pack LEDs information. This table is deprecated because the LEDs for the power modules' fans are no longer on the fan packs, the LEDs are on the power modules. See the MIB tables, componentLEDsTable and componentLEDsDetailsTable, for the power modules' LEDs. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.8.6.1not-accessibledeprecated
fanPackLEDsEntry
OBJECT-TYPE
Fan Pack LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1not-accessibledeprecated
ledFanPackIndex
OBJECT-TYPE
Fan Pack LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1INTEGER (0..128)read-onlydeprecated
ledFanPackId
OBJECT-TYPE
The numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4), fanPack5(5), fanPack6(6)}read-onlydeprecated
ledFanPackExists
OBJECT-TYPE
Indicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
ledFanPackError
OBJECT-TYPE
Indicates whether the fan pack error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4INTEGER {off(0), on(1), notAvailable(2)}read-onlydeprecated
fuelGauge
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10
fuelGaugeInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.1
fuelGaugeTable
OBJECT-TYPE
Table of Fuel Gauge information.
1.3.6.1.4.1.2.3.51.2.2.10.1.1not-accessiblemandatory
fuelGaugeEntry
OBJECT-TYPE
Fuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1not-accessiblemandatory
fuelGaugeIndex
OBJECT-TYPE
Fuel Gauge Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1INTEGERread-onlymandatory
fuelGaugePowerDomainNumber
OBJECT-TYPE
Fuel Gauge Table Power Domain Number.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2INTEGER {powerDomain1(1)}read-onlymandatory
fuelGaugeStatus
OBJECT-TYPE
Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3OCTET STRINGread-onlymandatory
fuelGaugePowerModules
OBJECT-TYPE
Fuel Gauge Table Power Module capacity in Watts in the power domain.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4OCTET STRINGread-onlymandatory
fuelGaugePowerManagementPolicySetting
OBJECT-TYPE
Power Management Policy Setting for each power domain. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6INTEGER {power-module-redundancy(0), power-module-redundancy-throttle(1), basic(2), power-source-redundancy(3), power-source-redundancy-throttle(4), notApplicable(255)}read-onlymandatory
fuelGaugeTotalPower
OBJECT-TYPE
This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7OCTET STRINGread-onlymandatory
fuelGaugeAllocatedPower
OBJECT-TYPE
This field displays the power that has been reserved in each power domain.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8OCTET STRINGread-onlymandatory
fuelGaugeRemainingPower
OBJECT-TYPE
This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9OCTET STRINGread-onlymandatory
fuelGaugePowerInUsed
OBJECT-TYPE
This field displays the total power being used in each power domain.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10OCTET STRINGread-onlymandatory
powerDomain1
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.2
powerDomain1Table
OBJECT-TYPE
Table of Power Domain 1.
1.3.6.1.4.1.2.3.51.2.2.10.2.1not-accessiblemandatory
powerDomain1Entry
OBJECT-TYPE
Fuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1not-accessiblemandatory
pd1Index
OBJECT-TYPE
Power Domain 1 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1INTEGERread-onlymandatory
pd1BayNumber
OBJECT-TYPE
Power Domain 1 Table Bay Number. The following Bay Number IDs are used: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), fanPackBay5(7), fanPackBay6(8), chassisfanBay1(9), chassisfanBay2(10), chassisfanBay3(11), chassisfanBay4(12), chassisfanBay5(13), chassisfanBay6(14), chassisfanBay7(15), chassisfanBay8(16), chassisfanBay9(17), chassisfanBay10(18), managementModuleBay1(19), managementModuleBay2(20), ioModuleBay1(21), ioModuleBay2(22), ioModuleBay3(23), ioModuleBay4(24), serverBladeBay1(25), serverBladeBay2(26), serverBladeBay3(27), serverBladeBay4(28), serverBladeBay5(29), serverBladeBay6(30), serverBladeBay7(31), serverBladeBay8(32), serverBladeBay9(33), serverBladeBay10(34), serverBladeBay11(35), serverBladeBay12(36), serverBladeBay13(37), serverBladeBay14(38), notApplicable(39)
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2OCTET STRINGread-onlymandatory
pd1BladePrimarySlot
OBJECT-TYPE
Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd1ModuleStatus
OBJECT-TYPE
Power Domain 1 Table Module Throttle Status.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)}read-onlymandatory
pd1ModuleName
OBJECT-TYPE
Power Domain 1 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5OCTET STRINGread-onlymandatory
pd1ModuleState
OBJECT-TYPE
Power Domain 1 Table Module State.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)}read-onlymandatory
pd1ModuleAllocatedPowerCurrent
OBJECT-TYPE
Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7OCTET STRINGread-onlymandatory
pd1ModuleAllocatedPowerMax
OBJECT-TYPE
Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8OCTET STRINGread-onlymandatory
pd1ModuleAllocatedPowerMin
OBJECT-TYPE
Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9OCTET STRINGread-onlymandatory
pd1ModuleCPUDutyCycles
OBJECT-TYPE
Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10OCTET STRINGread-onlymandatory
pd1ModuleThrottle
OBJECT-TYPE
Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd1ModulePowerCapabilities
OBJECT-TYPE
Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)}read-onlymandatory
pd1ModuleMeasuredOrStatic
OBJECT-TYPE
Power Domain 1 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13INTEGER {static(0), measured(1), notApplicable(255)}read-onlymandatory
pd1TopologyPath
OBJECT-TYPE
The topology path for the component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.14OCTET STRING (SIZE(0..100))read-onlymandatory
powerDomain1PowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.2.3
pd1PowerTrendingPeriod
OBJECT-TYPE
Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
pd1PowerTrendingSampleTable
OBJECT-TYPE
Table of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10not-accessiblemandatory
pd1PowerTrendingSampleEntry
OBJECT-TYPE
Power Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1not-accessiblemandatory
pd1PowerTrendingSampleIndex
OBJECT-TYPE
Power Domain 1 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1INTEGERread-onlymandatory
pd1PowerTrendingSampleTimeStamp
OBJECT-TYPE
Power Domain 1 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2OCTET STRINGread-onlymandatory
pd1PowerTrendingSampleAve
OBJECT-TYPE
Power Domain 1 Power Trending Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3OCTET STRINGread-onlymandatory
moduleInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4
bladeDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.1
bladeDetailsTable
OBJECT-TYPE
Table of Blade Module Details.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1not-accessiblemandatory
bladeDetailsEntry
OBJECT-TYPE
Blade Module Details entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1not-accessiblemandatory
bladeDetailsIndex
OBJECT-TYPE
Blade Module Details Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1INTEGERread-onlymandatory
bladeDetailsId
OBJECT-TYPE
Blade Module Details Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeDetailsMaxPowerConfig
OBJECT-TYPE
Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. Blade must be powered on to set this value. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3INTEGERread-writemandatory
bladeDetailsEffectiveClockRate
OBJECT-TYPE
Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4OCTET STRINGread-onlymandatory
bladeDetailsMaximumClockRate
OBJECT-TYPE
Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5OCTET STRINGread-onlymandatory
bladeDetailsPowerSaverMode
OBJECT-TYPE
When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsDynamicPowerSaver
OBJECT-TYPE
When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsDynamicPowerFavorPerformanceOverPower
OBJECT-TYPE
When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsPowerControl
OBJECT-TYPE
This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)}read-writemandatory
bladeDetailsPcapMin
OBJECT-TYPE
Blade Module Details Table power capping Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.10OCTET STRINGread-onlymandatory
bladeDetailsPcapGuaranteedMin
OBJECT-TYPE
Blade Module Details Table power capping Guaranteed Minimum value in watts. The blade must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.11OCTET STRINGread-onlymandatory
bladeDetailsPcapMax
OBJECT-TYPE
Blade Module Details Table power capping Maximum value in watts. The blade must support the advanced power management feature. If the value is '<max1> Watts,<max2> Watts', which means, - if bladeDetailsDynamicPowerSaver is enabled, it is <max2> - otherwise it is <max1> If the value of Pcap Max is 'notApplicable', it means the blade doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.12OCTET STRINGread-onlymandatory
bladePowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3
bladePowerTrendingPeriod
OBJECT-TYPE
Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module. Since the power trending data is constantly being computed and saved in the management application database, some queries of the bladePowerTrendingSampleTable may not provide information for a very short window of time. If the table returns empty, please wait a short period and retry the query.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
bladePowerTrendingBladeId
OBJECT-TYPE
Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-writemandatory
bladePowerTrendingTopologyPath
OBJECT-TYPE
The topology Path is a location identifier for a blade. The chassis and each installed blade is represented by a hardware topology tree, where each node in the tree represents a blade. The path to a particular blade consists of one or more <blade>,<instance> pairs, where each successive pair is a child of the previous parent pair. This topology path is used to identify blades such as blade storage devices. Some examples. A storage blade with a controller card plugged into slot 1 topology location would be represented as : 010103010301--> Storage Controller card #1 of Sub-Chassis #1 A storage blade with a controller card plugged into slot 2 topology location would be represented as : 010103010302--> Storage Controller card #2 of Sub-Chassis #1
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.3OCTET STRING (SIZE(0..100))read-writemandatory
bladePowerTrendingSampleTable
OBJECT-TYPE
Table of Blade Module Power Trending Information. Since the power trending data is constantly being computed and saved in the management application database, some queries of this table may not provide information for a very short window of time. If the table data returns empty,please wait a short period and retry the query.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10not-accessiblemandatory
bladePowerTrendingSampleEntry
OBJECT-TYPE
Blade Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1not-accessiblemandatory
bladePowerTrendingSampleIndex
OBJECT-TYPE
Blade Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1INTEGERread-onlymandatory
bladePowerTrendingSampleId
OBJECT-TYPE
Blade Module Power Trending Sample Table Blade Id. If the blade is defined using a topology location by using the scalar bladePowerTrendingTopologyPath, a zero will be displayed in the bladePowerTrendingSampleId.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladePowerTrendingSampleTimeStamp
OBJECT-TYPE
Blade Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3OCTET STRINGread-onlymandatory
bladePowerTrendingSampleMax
OBJECT-TYPE
Blade Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4OCTET STRINGread-onlymandatory
bladePowerTrendingSampleMin
OBJECT-TYPE
Blade Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5OCTET STRINGread-onlymandatory
bladePowerTrendingSampleAve
OBJECT-TYPE
Blade Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6OCTET STRINGread-onlymandatory
bladePowerTrendingSampleTopologyId
OBJECT-TYPE
Blade module topology path. This field will have a topology location when a blade is a storage blade or a blade defined with a sub chassis. If the blade is defined with a primary slot location by using the scalar bladePowerTrendingBladeId, 'not applicable' will be displayed in the bladePowerTrendingSampleTopologyId.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.7OCTET STRINGread-onlymandatory
switchDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.2
switchPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3
switchPowerTrendingPeriod
OBJECT-TYPE
Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
switchPowerTrendingSwitchId
OBJECT-TYPE
Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2INTEGER {module1(1), module2(2), module3(3), module4(4)}read-writemandatory
switchPowerTrendingSampleTable
OBJECT-TYPE
Table of Switch Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10not-accessiblemandatory
switchPowerTrendingSampleEntry
OBJECT-TYPE
Switch Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1not-accessiblemandatory
switchPowerTrendingSampleIndex
OBJECT-TYPE
Switch Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1INTEGERread-onlymandatory
switchPowerTrendingSampleId
OBJECT-TYPE
Switch Module Power Trending Sample Table Switch Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
switchPowerTrendingSampleTimeStamp
OBJECT-TYPE
Switch Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3OCTET STRINGread-onlymandatory
switchPowerTrendingSampleMax
OBJECT-TYPE
Switch Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4OCTET STRINGread-onlymandatory
switchPowerTrendingSampleMin
OBJECT-TYPE
Switch Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5OCTET STRINGread-onlymandatory
switchPowerTrendingSampleAve
OBJECT-TYPE
Switch Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6OCTET STRINGread-onlymandatory
chassisFanDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.3
chassisFanPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3
chassisFanPowerTrendingPeriod
OBJECT-TYPE
Specify time period for chassis fan module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for chassis fan module.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
chassisFanPowerTrendingId
OBJECT-TYPE
Chass fan mModule power trending fan ID. NOTE: The ID should be configured before displaying the chassisFanPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)}read-writemandatory
chassisFanPowerTrendingSampleTable
OBJECT-TYPE
Table of chassis fan Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10not-accessiblemandatory
chassisFanPowerTrendingSampleEntry
OBJECT-TYPE
Chassis fan Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1not-accessiblemandatory
chassisFanPowerTrendingSampleIndex
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1INTEGERread-onlymandatory
chassisFanPowerTrendingSampleId
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)}read-onlymandatory
chassisFanPowerTrendingSampleTimeStamp
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3OCTET STRINGread-onlymandatory
chassisFanPowerTrendingSampleMax
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4OCTET STRINGread-onlymandatory
chassisFanPowerTrendingSampleMin
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5OCTET STRINGread-onlymandatory
chassisFanPowerTrendingSampleAve
OBJECT-TYPE
Chassis fan Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6OCTET STRINGread-onlymandatory
chassisInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5
chassisConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.1
chassisTotalDCPowerAvailable
OBJECT-TYPE
Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.1OCTET STRINGread-onlymandatory
chassisTotalPowerInUsed
OBJECT-TYPE
Chassis total power being used, which displays the total power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis cooling devices) for the chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.2OCTET STRINGread-onlymandatory
chassisTotalThermalOutput
OBJECT-TYPE
Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total input power in use. (1 Watt = 3.412 BTU/hour).
1.3.6.1.4.1.2.3.51.2.2.10.5.1.3OCTET STRINGread-onlymandatory
chassisPowerService
OBJECT-TYPE
The chassis power service mode. NOTE: This MIB object is for BCS only. This object has been deprecated. See the object, powerModuleDescription, for similar information.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.5INTEGER {volt110(1), volt220(2), notAvailable(255)}read-onlydeprecated
chassisPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.3
chassisPowerTrendingPeriod
OBJECT-TYPE
Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
chassisPowerTrendingSampleTable
OBJECT-TYPE
Table of Chassis Power Trending Sample Information in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10not-accessiblemandatory
chassisPowerTrendingSampleEntry
OBJECT-TYPE
Chassis Power Trending Sample entry in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1not-accessiblemandatory
chassisPowerTrendingSampleIndex
OBJECT-TYPE
Chassis Power Trending Sample Index in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1INTEGERread-onlymandatory
chassisPowerTrendingSampleTimeStamp
OBJECT-TYPE
Chassis Power Trending Sample Timestamp in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2OCTET STRINGread-onlymandatory
chassisPowerTrendingSampleAve
OBJECT-TYPE
Chassis Power Trending Sample Average Power in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3OCTET STRINGread-onlymandatory
chassisThermalTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.5
chassisThermalTrendingPeriod
OBJECT-TYPE
Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
rearLEDCardThermalTrendingTable
OBJECT-TYPE
Table of rear LED card Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10not-accessiblemandatory
rearLEDCardThermalTrendingEntry
OBJECT-TYPE
Rear LED Card Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1not-accessiblemandatory
rearLEDCardThermalTrendingIndex
OBJECT-TYPE
Rear LED Card Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1INTEGERread-onlymandatory
rearLEDCardThermalTrendingTimeStamp
OBJECT-TYPE
Rear LED Card Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2OCTET STRINGread-onlymandatory
rearLEDCardThermalTrendingTemperatureAvg
OBJECT-TYPE
Rear LED Card Thermal Trending Table Average Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3OCTET STRINGread-onlymandatory
rearLEDCardThermalTrendingTemperatureMin
OBJECT-TYPE
Rear LED Card Thermal Trending Table Minumum Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.4OCTET STRINGread-onlymandatory
rearLEDCardThermalTrendingTemperatureMax
OBJECT-TYPE
Rear LED Card Thermal Trending Table Maximum Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.5OCTET STRINGread-onlymandatory
cfmThermalTrendingTable
OBJECT-TYPE
Table of Cubic Feet per Minute Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60not-accessiblemandatory
cfmThermalTrendingEntry
OBJECT-TYPE
Chassis CFM Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1not-accessiblemandatory
cfmThermalTrendingIndex
OBJECT-TYPE
Cubic Feet per Minute Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.1INTEGERread-onlymandatory
cfmThermalTrendingTimeStamp
OBJECT-TYPE
Cubic Feet per Minute Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.2OCTET STRINGread-onlymandatory
cfmThermalTrendingCurrentCFM
OBJECT-TYPE
Cubic Feet per Minute Thermal Trending Table The Current CFM of air flow calculated at this sample time.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.3OCTET STRINGread-onlymandatory
cfmThermalTrendingMaxCFM
OBJECT-TYPE
Cubic Feet per Minute Thermal Trending Table The Maximum CFM of air flow the chassis can provide at this sample time.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.60.1.4OCTET STRINGread-onlymandatory
ehiThermalTrendingTable
OBJECT-TYPE
Table of Exhaust Heat Index Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70not-accessiblemandatory
ehiThermalTrendingEntry
OBJECT-TYPE
Chassis Exhaust Heat Index Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1not-accessiblemandatory
ehiThermalTrendingIndex
OBJECT-TYPE
Exhaust Heat Index Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.1INTEGERread-onlymandatory
ehiThermalTrendingTimeStamp
OBJECT-TYPE
Chassis Exhaust Heat Index Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.2OCTET STRINGread-onlymandatory
ehiThermalTrendingMinEHI
OBJECT-TYPE
Chassis Exhaust Heat Index Thermal Trending Table Minimum Exhaust Heat Index since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.3OCTET STRINGread-onlymandatory
ehiThermalTrendingMaxEHI
OBJECT-TYPE
Chassis Exhaust Heat Index Thermal Trending Table Maximum Exhaust Heat Index since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.4OCTET STRINGread-onlymandatory
ehiThermalTrendingAvgEHI
OBJECT-TYPE
Chassis Exhaust Heat Index Thermal Trending Table Average of last 2 Exhaust Heat Index calculations since last reboot.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.70.1.5OCTET STRINGread-onlymandatory
powerPolicyInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.6
powerPolicyTable
OBJECT-TYPE
Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain.
1.3.6.1.4.1.2.3.51.2.2.10.6.1not-accessiblemandatory
powerPolicyEntry
OBJECT-TYPE
Power Policy Entry
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1not-accessiblemandatory
powerPolicyIndex
OBJECT-TYPE
The unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1INTEGERread-onlymandatory
powerPolicyPowerDomainNumber
OBJECT-TYPE
The power domain number which this row is associated with.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2INTEGER {powerDomain1(1), powerDomain2(2)}read-onlymandatory
powerPolicyName
OBJECT-TYPE
The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Blade Throttling Allowed Very similar to the Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one power source fails.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3OCTET STRINGread-onlymandatory
powerPolicyPwrSupplyFailureLimit
OBJECT-TYPE
The maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4INTEGERread-onlymandatory
powerPolicyMaxPowerLimit
OBJECT-TYPE
The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5INTEGERread-onlymandatory
powerPolicyEstimatedUtilization
OBJECT-TYPE
The estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6INTEGERread-onlymandatory
powerPolicyActivate
OBJECT-TYPE
When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the MM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
users
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.17
mmUsers
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.17.1
currentlyLoggedInTable
OBJECT-TYPE
Table of MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1not-accessiblemandatory
currentlyLoggedInEntry
OBJECT-TYPE
MM users currently logged in entries.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1not-accessiblemandatory
currentlyLoggedInEntryIndex
OBJECT-TYPE
Index for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1INTEGER (0..255)read-onlymandatory
currentlyLoggedInEntryUserId
OBJECT-TYPE
Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2OCTET STRING (SIZE(0..64))read-onlymandatory
currentlyLoggedInEntryAccMethod
OBJECT-TYPE
Access method for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3OCTET STRING (SIZE(0..32))read-onlymandatory
vpdInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21
chassisInfoVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.1
chassisVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.1.1
chassisVpdMachineType
OBJECT-TYPE
Machine type VPD information (from System BIOS). This field must be four alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.1OCTET STRINGread-writedeprecated
chassisVpdMachineModel
OBJECT-TYPE
Machine model VPD information (from System BIOS). This field must be three alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.2OCTET STRINGread-writedeprecated
chassisSerialNumber
OBJECT-TYPE
Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.3OCTET STRINGread-writedeprecated
chassisUUID
OBJECT-TYPE
Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.4OCTET STRINGread-writedeprecated
chassisManufacturingId
OBJECT-TYPE
Machine chassis manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.5OCTET STRINGread-onlydeprecated
chassisHardwareRevision
OBJECT-TYPE
Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.6INTEGERread-onlydeprecated
chassisFruNumber
OBJECT-TYPE
Machine chassis FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.7OCTET STRINGread-onlydeprecated
chassisManufDate
OBJECT-TYPE
Machine chassis manufacture date.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.8OCTET STRINGread-onlydeprecated
chassisPartNumber
OBJECT-TYPE
Machine chassis part number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.9OCTET STRINGread-onlydeprecated
chassisFruSerial
OBJECT-TYPE
Machine chassis FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.10OCTET STRINGread-onlydeprecated
chassisManufacturingIDNumber
OBJECT-TYPE
Machine chassis manufacturer ID Number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.11OCTET STRINGread-onlydeprecated
chassisProductId
OBJECT-TYPE
Machine chassis product ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.12OCTET STRINGread-onlydeprecated
chassisSubManufacturerId
OBJECT-TYPE
Machine chassis subsystem manufacturer.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.13OCTET STRINGread-onlydeprecated
chassisClei
OBJECT-TYPE
Machine chassis Common Language Equipment Identification (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.1.1.14OCTET STRINGread-onlydeprecated
chassisHardwareRevisionString
OBJECT-TYPE
Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.16OCTET STRINGread-onlydeprecated
mmHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.2
mmHardwareVpdTable
OBJECT-TYPE
Table of the management module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1not-accessibledeprecated
mmHardwareVpdEntry
OBJECT-TYPE
Management module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1not-accessibledeprecated
mmHardwareVpdIndex
OBJECT-TYPE
Management module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1INTEGERread-onlydeprecated
mmHardwareVpdBayNumber
OBJECT-TYPE
Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2OCTET STRINGread-onlydeprecated
mmHardwareVpdManufacturingId
OBJECT-TYPE
Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3OCTET STRINGread-onlydeprecated
mmHardwareVpdFruNumber
OBJECT-TYPE
Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4OCTET STRINGread-onlydeprecated
mmHardwareVpdHardwareRevision
OBJECT-TYPE
Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5INTEGERread-onlydeprecated
mmHardwareVpdUuid
OBJECT-TYPE
Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6OCTET STRINGread-onlydeprecated
mmHardwareVpdManufDate
OBJECT-TYPE
Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7OCTET STRINGread-onlydeprecated
mmHardwareVpdPartNumber
OBJECT-TYPE
Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8OCTET STRINGread-onlydeprecated
mmHardwareVpdFruSerial
OBJECT-TYPE
Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9OCTET STRINGread-onlydeprecated
mmHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10OCTET STRINGread-onlydeprecated
mmHardwareVpdProductId
OBJECT-TYPE
Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11OCTET STRINGread-onlydeprecated
mmHardwareVpdSubManufacturerId
OBJECT-TYPE
Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12OCTET STRINGread-onlydeprecated
mmHardwareVpdClei
OBJECT-TYPE
Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13OCTET STRINGread-onlydeprecated
mmHardwareVpdHardwareRevisionString
OBJECT-TYPE
Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14OCTET STRINGread-onlydeprecated
mmFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.3
mmMainApplVpdTable
OBJECT-TYPE
Table of MM Firmware VPD.
1.3.6.1.4.1.2.3.51.2.2.21.3.1not-accessibledeprecated
mmMainApplVpdEntry
OBJECT-TYPE
MM Firmware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1not-accessibledeprecated
mmMainApplVpdIndex
OBJECT-TYPE
Firmware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1INTEGERread-onlydeprecated
mmMainApplVpdName
OBJECT-TYPE
Firmware VPD name description. 'MM firmware' indicates the running firmware of the MM. 'MM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2OCTET STRINGread-onlydeprecated
mmMainApplVpdBuildId
OBJECT-TYPE
Firmware VPD build identification.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3OCTET STRINGread-onlydeprecated
mmMainApplVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4OCTET STRINGread-onlydeprecated
mmMainApplVpdFilename
OBJECT-TYPE
Firmware VPD file name.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5OCTET STRINGread-onlydeprecated
mmMainApplVpdBuildDate
OBJECT-TYPE
Firmware VPD build date.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6OCTET STRINGread-onlydeprecated
bladeHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.4
bladeHardwareVpdTable
OBJECT-TYPE
Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1not-accessibledeprecated
bladeHardwareVpdEntry
OBJECT-TYPE
Blade hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1not-accessibledeprecated
bladeHardwareVpdIndex
OBJECT-TYPE
Blade hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1INTEGERread-onlydeprecated
bladeHardwareVpdBayNumber
OBJECT-TYPE
Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2OCTET STRINGread-onlydeprecated
bladeHardwareVpdManufacturingId
OBJECT-TYPE
Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3OCTET STRINGread-onlydeprecated
bladeHardwareVpdFruNumber
OBJECT-TYPE
Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4OCTET STRINGread-onlydeprecated
bladeHardwareVpdHardwareRevision
OBJECT-TYPE
Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5INTEGERread-onlydeprecated
bladeHardwareVpdSerialNumber
OBJECT-TYPE
Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6OCTET STRINGread-onlydeprecated
bladeHardwareVpdMachineType
OBJECT-TYPE
Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7OCTET STRINGread-onlydeprecated
bladeHardwareVpdUuid
OBJECT-TYPE
Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8OCTET STRINGread-onlydeprecated
bladeHardwareVpdManufDate
OBJECT-TYPE
Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9OCTET STRINGread-onlydeprecated
bladeHardwareVpdPartNumber
OBJECT-TYPE
Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10OCTET STRINGread-onlydeprecated
bladeHardwareVpdFruSerial
OBJECT-TYPE
Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11OCTET STRINGread-onlydeprecated
bladeHardwareVpdMachineModel
OBJECT-TYPE
Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12OCTET STRINGread-onlydeprecated
bladeHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13OCTET STRINGread-onlydeprecated
bladeHardwareVpdProductId
OBJECT-TYPE
Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14OCTET STRINGread-onlydeprecated
bladeHardwareVpdSubManufacturerId
OBJECT-TYPE
Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15OCTET STRINGread-onlydeprecated
bladeHardwareVpdClei
OBJECT-TYPE
Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16OCTET STRINGread-onlydeprecated
bladeHardwareVpdHardwareRevisionString
OBJECT-TYPE
Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17OCTET STRINGread-onlydeprecated
bladeDaughterVpdCardType
OBJECT-TYPE
Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20INTEGER {unknown(0), networkExpansion(1), storageExpansion(2), pciExpansion(3), genericExpansion(4)}read-onlydeprecated
bladeDaughterVpdManufacturingId
OBJECT-TYPE
Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21OCTET STRINGread-onlydeprecated
bladeDaughterVpdFruNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22OCTET STRINGread-onlydeprecated
bladeDaughterVpdHardwareRevision
OBJECT-TYPE
Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23INTEGERread-onlydeprecated
bladeDaughterVpdSerialNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24OCTET STRINGread-onlydeprecated
bladeDaughterVpdMachineType
OBJECT-TYPE
Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25OCTET STRINGread-onlydeprecated
bladeDaughterVpdUuid
OBJECT-TYPE
Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26OCTET STRINGread-onlydeprecated
bladeDaughterVpdManufDate
OBJECT-TYPE
Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27OCTET STRINGread-onlydeprecated
bladeDaughterVpdPartNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28OCTET STRINGread-onlydeprecated
bladeDaughterVpdFruSerial
OBJECT-TYPE
Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29OCTET STRINGread-onlydeprecated
bladeDaughterVpdManufacturingIDNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30OCTET STRINGread-onlydeprecated
bladeDaughterVpdProductId
OBJECT-TYPE
Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31OCTET STRINGread-onlydeprecated
bladeDaughterVpdSubManufacturerId
OBJECT-TYPE
Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32OCTET STRINGread-onlydeprecated
bladeDaughterVpdClei
OBJECT-TYPE
Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33OCTET STRINGread-onlydeprecated
bladeDaughterVpdHardwareRevisionString
OBJECT-TYPE
Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34OCTET STRINGread-onlydeprecated
bladeMACAddressVpdTable
OBJECT-TYPE
Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2not-accessiblemandatory
bladeMACAddressVpdEntry
OBJECT-TYPE
Blade MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1not-accessiblemandatory
bladeMACAddressVpdIndex
OBJECT-TYPE
Blade index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1INTEGERread-onlymandatory
bladeMACAddress1Vpd
OBJECT-TYPE
Blade MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2OCTET STRINGread-onlymandatory
bladeMACAddress2Vpd
OBJECT-TYPE
Blade MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3OCTET STRINGread-onlymandatory
bladeMACAddress3Vpd
OBJECT-TYPE
Blade MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4OCTET STRINGread-onlymandatory
bladeMACAddress4Vpd
OBJECT-TYPE
Blade MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5OCTET STRINGread-onlymandatory
bladeMACAddress5Vpd
OBJECT-TYPE
Blade MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6OCTET STRINGread-onlymandatory
bladeMACAddress6Vpd
OBJECT-TYPE
Blade MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7OCTET STRINGread-onlymandatory
bladeMACAddress7Vpd
OBJECT-TYPE
Blade MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8OCTET STRINGread-onlymandatory
bladeMACAddress8Vpd
OBJECT-TYPE
Blade MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress1Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress2Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress3Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress4Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress5Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress6Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress7Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress8Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107OCTET STRINGread-onlymandatory
bladeSideCardMACAddress1Vpd
OBJECT-TYPE
Blade side card MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164OCTET STRINGread-onlymandatory
bladeSideCardMACAddress2Vpd
OBJECT-TYPE
Blade side card MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165OCTET STRINGread-onlymandatory
bladeSideCardMACAddress3Vpd
OBJECT-TYPE
Blade side card MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166OCTET STRINGread-onlymandatory
bladeSideCardMACAddress4Vpd
OBJECT-TYPE
Blade side card MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167OCTET STRINGread-onlymandatory
bladeSideCardMACAddress5Vpd
OBJECT-TYPE
Blade side card MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168OCTET STRINGread-onlymandatory
bladeSideCardMACAddress6Vpd
OBJECT-TYPE
Blade side card MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169OCTET STRINGread-onlymandatory
bladeSideCardMACAddress7Vpd
OBJECT-TYPE
Blade side card MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170OCTET STRINGread-onlymandatory
bladeSideCardMACAddress8Vpd
OBJECT-TYPE
Blade side card MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171OCTET STRINGread-onlymandatory
bladeExpCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5not-accessibledeprecated
bladeExpCardVpdEntry
OBJECT-TYPE
Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1not-accessibledeprecated
bladeExpCardVpdIndex
OBJECT-TYPE
Blade expansion card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1INTEGERread-onlydeprecated
bladeExpCardVpdBayNumber
OBJECT-TYPE
Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2OCTET STRINGread-onlydeprecated
bladeExpCardVpdManufacturingId
OBJECT-TYPE
Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3OCTET STRINGread-onlydeprecated
bladeExpCardVpdFruNumber
OBJECT-TYPE
Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4OCTET STRINGread-onlydeprecated
bladeExpCardVpdHardwareRevision
OBJECT-TYPE
Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5INTEGERread-onlydeprecated
bladeExpCardVpdSerialNumber
OBJECT-TYPE
Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6OCTET STRINGread-onlydeprecated
bladeExpCardVpdMachineType
OBJECT-TYPE
Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7OCTET STRINGread-onlydeprecated
bladeExpCardVpdUuid
OBJECT-TYPE
Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8OCTET STRINGread-onlydeprecated
bladeExpCardVpdManufDate
OBJECT-TYPE
Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9OCTET STRINGread-onlydeprecated
bladeExpCardVpdPartNumber
OBJECT-TYPE
Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10OCTET STRINGread-onlydeprecated
bladeExpCardVpdFruSerial
OBJECT-TYPE
Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11OCTET STRINGread-onlydeprecated
bladeExpCardVpdMachineModel
OBJECT-TYPE
Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12OCTET STRINGread-onlydeprecated
bladeExpCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13OCTET STRINGread-onlydeprecated
bladeExpCardVpdProductId
OBJECT-TYPE
Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14OCTET STRINGread-onlydeprecated
bladeExpCardVpdSubManufacturerId
OBJECT-TYPE
Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15OCTET STRINGread-onlydeprecated
bladeExpCardVpdClei
OBJECT-TYPE
Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16OCTET STRINGread-onlydeprecated
bladeExpCardVpdBladeBayNumber
OBJECT-TYPE
Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19OCTET STRINGread-onlydeprecated
bladeExpCardVpdCardTypeInfo
OBJECT-TYPE
Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21INTEGER {unknown(0), bladeEthernetExpCard(1), bladeFiberChannelExpCard(2), serialPortExpCard(3), bladeOpticalPassThrough(4), bladeInfinibandExpCard(5), bladeIscsiExpCard(6), bladeGenericExpCard(7), bladeNetworkCFFeExpCard(8), bladeSASConnectivityCard(9), bladeSATAConnectivityCard(10), bladeNetworkCFFzExpCard(11), bladeNetworkCNAExpCard(12)}read-onlydeprecated
bladeExpCardVpdHighSpeed
OBJECT-TYPE
Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22INTEGER {no(0), yes(1), notApplicable(255)}read-onlydeprecated
bladeExpCardVpdHardwareRevisionString
OBJECT-TYPE
Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpdTable
OBJECT-TYPE
Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7not-accessibledeprecated
bladeAndExpCardWwnGuidVpdEntry
OBJECT-TYPE
Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1not-accessibledeprecated
bladeAndExpCardWwnGuidVpdIndex
OBJECT-TYPE
Blade or expansion card index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1INTEGERread-onlydeprecated
bladeAndExpCardWwnGuidVpdBayNumber
OBJECT-TYPE
Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpdName
OBJECT-TYPE
The name of the blade or expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpdBladeBayNumber
OBJECT-TYPE
For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpdType
OBJECT-TYPE
Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5INTEGER {notAvailable(0), wwn(1), guid(2), sas(3)}read-onlydeprecated
bladeAndExpCardWwnGuidVpd1
OBJECT-TYPE
Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd2
OBJECT-TYPE
Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd3
OBJECT-TYPE
Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd4
OBJECT-TYPE
Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd5
OBJECT-TYPE
Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd6
OBJECT-TYPE
Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd7
OBJECT-TYPE
Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12OCTET STRINGread-onlydeprecated
bladeAndExpCardWwnGuidVpd8
OBJECT-TYPE
Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13OCTET STRINGread-onlydeprecated
bladeManagementCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8not-accessibledeprecated
bladeManagementCardVpdEntry
OBJECT-TYPE
Blade management card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1not-accessibledeprecated
bladeManagementCardVpdIndex
OBJECT-TYPE
Blade management card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1INTEGERread-onlydeprecated
bladeManagementCardVpdBayNumber
OBJECT-TYPE
Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2OCTET STRINGread-onlydeprecated
bladeManagementCardVpdManufacturingId
OBJECT-TYPE
Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3OCTET STRINGread-onlydeprecated
bladeManagementCardVpdFruNumber
OBJECT-TYPE
Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4OCTET STRINGread-onlydeprecated
bladeManagementCardVpdHardwareRevision
OBJECT-TYPE
Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5INTEGERread-onlydeprecated
bladeManagementCardVpdSerialNumber
OBJECT-TYPE
Blade management card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6OCTET STRINGread-onlydeprecated
bladeManagementCardVpdMachineType
OBJECT-TYPE
Blade management card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7OCTET STRINGread-onlydeprecated
bladeManagementCardVpdUuid
OBJECT-TYPE
Blade management card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8OCTET STRINGread-onlydeprecated
bladeManagementCardVpdManufDate
OBJECT-TYPE
Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9OCTET STRINGread-onlydeprecated
bladeManagementCardVpdPartNumber
OBJECT-TYPE
Blade management card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10OCTET STRINGread-onlydeprecated
bladeManagementCardVpdFruSerial
OBJECT-TYPE
Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11OCTET STRINGread-onlydeprecated
bladeManagementCardVpdMachineModel
OBJECT-TYPE
Blade management card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12OCTET STRINGread-onlydeprecated
bladeManagementCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13OCTET STRINGread-onlydeprecated
bladeManagementCardVpdProductId
OBJECT-TYPE
Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14OCTET STRINGread-onlydeprecated
bladeManagementCardVpdSubManufacturerId
OBJECT-TYPE
Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15OCTET STRINGread-onlydeprecated
bladeManagementCardVpdClei
OBJECT-TYPE
Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16OCTET STRINGread-onlydeprecated
bladeManagementCardVpdHardwareRevisionString
OBJECT-TYPE
Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17OCTET STRINGread-onlydeprecated
bladeFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.5
bladeBiosVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.1not-accessibledeprecated
bladeBiosVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1not-accessibledeprecated
bladeBiosVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1INTEGERread-onlydeprecated
bladeBiosVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlydeprecated
bladeBiosVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
bladeBiosVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlydeprecated
bladeBiosVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5OCTET STRINGread-onlydeprecated
bladeBiosVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6OCTET STRINGread-onlydeprecated
bladeBiosVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7OCTET STRINGread-onlydeprecated
bladeBiosVpdDate
OBJECT-TYPE
The date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8OCTET STRINGread-onlydeprecated
bladeBiosVpdLevelStatus
OBJECT-TYPE
The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9OCTET STRINGread-onlydeprecated
bladeDiagsVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.2not-accessibledeprecated
bladeDiagsVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1not-accessibledeprecated
bladeDiagsVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1INTEGERread-onlydeprecated
bladeDiagsVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlydeprecated
bladeDiagsVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3INTEGER {false(0), true(1)}read-onlydeprecated
bladeDiagsVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlydeprecated
bladeDiagsVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5OCTET STRINGread-onlydeprecated
bladeDiagsVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6OCTET STRINGread-onlydeprecated
bladeDiagsVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7OCTET STRINGread-onlydeprecated
bladeDiagsVpdDate
OBJECT-TYPE
The date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8OCTET STRINGread-onlydeprecated
bladeDiagsVpdLevelStatus
OBJECT-TYPE
The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9OCTET STRINGread-onlydeprecated
bladeSysMgmtProcVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.3not-accessibledeprecated
bladeSysMgmtProcVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1not-accessibledeprecated
bladeSysMgmtProcVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1INTEGERread-onlydeprecated
bladeSysMgmtProcVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlydeprecated
bladeSysMgmtProcVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3INTEGER {false(0), true(1)}read-onlydeprecated
bladeSysMgmtProcVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlydeprecated
bladeSysMgmtProcVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5OCTET STRINGread-onlydeprecated
bladeSysMgmtProcVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6OCTET STRINGread-onlydeprecated
bladeSysMgmtProcVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7OCTET STRINGread-onlydeprecated
bladeSysMgmtProcVpdLevelStatus
OBJECT-TYPE
The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8OCTET STRINGread-onlydeprecated
smHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.6
smHardwareVpdTable
OBJECT-TYPE
Table of the switch module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1not-accessibledeprecated
smHardwareVpdEntry
OBJECT-TYPE
Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1not-accessibledeprecated
smHardwareVpdIndex
OBJECT-TYPE
Switch module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1INTEGERread-onlydeprecated
smHardwareVpdBayNumber
OBJECT-TYPE
Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2OCTET STRINGread-onlydeprecated
smHardwareVpdManufacturingId
OBJECT-TYPE
Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3OCTET STRINGread-onlydeprecated
smHardwareVpdFruNumber
OBJECT-TYPE
Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4OCTET STRINGread-onlydeprecated
smHardwareVpdHardwareRevision
OBJECT-TYPE
Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5INTEGERread-onlydeprecated
smHardwareVpdUuid
OBJECT-TYPE
Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8OCTET STRINGread-onlydeprecated
smHardwareVpdManufDate
OBJECT-TYPE
Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9OCTET STRINGread-onlydeprecated
smHardwareVpdPartNumber
OBJECT-TYPE
Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10OCTET STRINGread-onlydeprecated
smHardwareVpdFruSerial
OBJECT-TYPE
Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11OCTET STRINGread-onlydeprecated
smHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12OCTET STRINGread-onlydeprecated
smHardwareVpdProductId
OBJECT-TYPE
Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13OCTET STRINGread-onlydeprecated
smHardwareVpdSubManufacturerId
OBJECT-TYPE
Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14OCTET STRINGread-onlydeprecated
smHardwareVpdClei
OBJECT-TYPE
Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15OCTET STRINGread-onlydeprecated
smHardwareVpdWwnGuid
OBJECT-TYPE
Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16OCTET STRINGread-onlydeprecated
smHardwareVpdWwnGuidType
OBJECT-TYPE
The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17OCTET STRINGread-onlydeprecated
smHardwareVpdWidth
OBJECT-TYPE
The width of the switch module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18INTEGERread-onlydeprecated
smHardwareVpdHardwareRevisionString
OBJECT-TYPE
Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20OCTET STRINGread-onlydeprecated
smFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.7
smMainAppVpdTable
OBJECT-TYPE
Switch module main application VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.1not-accessibledeprecated
smMainAppVpdEntry
OBJECT-TYPE
Switch module main application VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1not-accessibledeprecated
smMainAppVpdIndex
OBJECT-TYPE
Switch module main application VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1INTEGERread-onlydeprecated
smMainAppVpdId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlydeprecated
smMainAppVpdExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
smMainAppVpdSwitchType
OBJECT-TYPE
Indicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)}read-onlydeprecated
smMainApp1VpdBuildId
OBJECT-TYPE
Switch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5OCTET STRINGread-onlydeprecated
smMainApp1VpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6OCTET STRINGread-onlydeprecated
smMainApp1VpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7OCTET STRINGread-onlydeprecated
smMainApp2VpdBuildId
OBJECT-TYPE
Switch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8OCTET STRINGread-onlydeprecated
smMainApp2VpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9OCTET STRINGread-onlydeprecated
smMainApp2VpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10OCTET STRINGread-onlydeprecated
smMainApp3VpdBuildId
OBJECT-TYPE
I/O Module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11OCTET STRINGread-onlydeprecated
smMainApp3VpdBuildDate
OBJECT-TYPE
I/O Module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12OCTET STRINGread-onlydeprecated
smMainApp3VpdRevisionNumber
OBJECT-TYPE
I/O Module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13OCTET STRINGread-onlydeprecated
smMainAppVpdSwitchSubType
OBJECT-TYPE
Indicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)}read-onlydeprecated
smBootRomVpdTable
OBJECT-TYPE
Switch module boot ROM VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.2not-accessibledeprecated
smBootRomVpdEntry
OBJECT-TYPE
Switch module boot ROM VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1not-accessibledeprecated
smBootRomVpdIndex
OBJECT-TYPE
Switch module boot ROM VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1INTEGERread-onlydeprecated
smBootRomVpdId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlydeprecated
smBootRomVpdExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3INTEGER {false(0), true(1)}read-onlydeprecated
smBootRomVpdSwitchType
OBJECT-TYPE
Indicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)}read-onlydeprecated
smBootRomVpdBuildId
OBJECT-TYPE
Switch module firmware build ID.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5OCTET STRINGread-onlydeprecated
smBootRomVpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6OCTET STRINGread-onlydeprecated
smBootRomVpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7OCTET STRINGread-onlydeprecated
smBootRomVpdSwitchSubType
OBJECT-TYPE
Indicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)}read-onlydeprecated
pmHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.8
pmHardwareVpdTable
OBJECT-TYPE
Table of the power module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1not-accessibledeprecated
pmHardwareVpdEntry
OBJECT-TYPE
Power module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1not-accessibledeprecated
pmHardwareVpdIndex
OBJECT-TYPE
Power module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1INTEGERread-onlydeprecated
pmHardwareVpdBayNumber
OBJECT-TYPE
Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2OCTET STRINGread-onlydeprecated
pmHardwareVpdManufacturingId
OBJECT-TYPE
Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3OCTET STRINGread-onlydeprecated
pmHardwareVpdFruNumber
OBJECT-TYPE
Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4OCTET STRINGread-onlydeprecated
pmHardwareVpdHardwareRevision
OBJECT-TYPE
Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5INTEGERread-onlydeprecated
pmHardwareVpdUuid
OBJECT-TYPE
Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8OCTET STRINGread-onlydeprecated
pmHardwareVpdManufDate
OBJECT-TYPE
Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9OCTET STRINGread-onlydeprecated
pmHardwareVpdPartNumber
OBJECT-TYPE
Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10OCTET STRINGread-onlydeprecated
pmHardwareVpdFruSerial
OBJECT-TYPE
Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11OCTET STRINGread-onlydeprecated
pmHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12OCTET STRINGread-onlydeprecated
pmHardwareVpdProductId
OBJECT-TYPE
Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13OCTET STRINGread-onlydeprecated
pmHardwareVpdSubManufacturerId
OBJECT-TYPE
Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14OCTET STRINGread-onlydeprecated
pmHardwareVpdClei
OBJECT-TYPE
Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15OCTET STRINGread-onlydeprecated
pmHardwareVpdHardwareRevisionString
OBJECT-TYPE
Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.9
rearLEDCardHardwareVpdManufacturingId
OBJECT-TYPE
Rear LED card hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.3OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdFruNumber
OBJECT-TYPE
Rear LED card hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.4OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdHardwareRevision
OBJECT-TYPE
Rear LED card hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.9.5INTEGERread-onlydeprecated
rearLEDCardHardwareVpdUuid
OBJECT-TYPE
Rear LED card hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.8OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Rear LED card hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.9OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdProductId
OBJECT-TYPE
Rear LED card hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.10OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdSubManufacturerId
OBJECT-TYPE
Rear LED card hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.11OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdClei
OBJECT-TYPE
Rear LED card hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.12OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdHardwareRevisionString
OBJECT-TYPE
Rear LED card hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.9.17OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdManufDate
OBJECT-TYPE
Rear LED card hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.9.18OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdPartNumber
OBJECT-TYPE
Rear LED card hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.9.19OCTET STRINGread-onlydeprecated
rearLEDCardHardwareVpdFruSerial
OBJECT-TYPE
Rear LED card hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.9.20OCTET STRINGread-onlydeprecated
chassisFanFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.12
chassisFanControllerVPDTable
OBJECT-TYPE
Table of chassis fan controller firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.12.1not-accessibledeprecated
chassisFanControllerVPDEntry
OBJECT-TYPE
Chassis fan controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1not-accessibledeprecated
chassisFanControllerVpdIndex
OBJECT-TYPE
Chassis fan controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1INTEGERread-onlydeprecated
chassisFanControllerVpdId
OBJECT-TYPE
The numeric chassis fan ID.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2INTEGER {chassisFan1(1), chassisFan2(2), chassisFan3(3), chassisFan4(4), chassisFan5(5), chassisFan6(6), chassisFan7(7), chassisFan8(8), chassisFan9(9), chassisFan10(10)}read-onlydeprecated
chassisFanControllerVpdExists
OBJECT-TYPE
Indicates whether the chassis fan specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
chassisFanControllerVpdRevision
OBJECT-TYPE
The revision of the chassis fan controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7OCTET STRINGread-onlydeprecated
chassisFanHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.13
chassisFanHardwareVpdTable
OBJECT-TYPE
Table of the chassis fan hardware components.
1.3.6.1.4.1.2.3.51.2.2.21.13.1not-accessibledeprecated
chassisFanHardwareVpdEntry
OBJECT-TYPE
Chassis fan hardware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1not-accessibledeprecated
chassisFanHardwareVpdIndex
OBJECT-TYPE
Chassis fan hardware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1INTEGERread-onlydeprecated
chassisFanHardwareVpdBayNumber
OBJECT-TYPE
Chassis fan hardware VPD Bay number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdManufacturingId
OBJECT-TYPE
Chassis fan hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdFruNumber
OBJECT-TYPE
Chassis fan hardware VPD FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdHardwareRevision
OBJECT-TYPE
Chassis fan hardware VPD hardware revision.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5INTEGERread-onlydeprecated
chassisFanHardwareVpdUuid
OBJECT-TYPE
Chassis fan hardware VPD UUID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdManufDate
OBJECT-TYPE
Chassis fan hardware VPD manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdPartNumber
OBJECT-TYPE
Chassis fan hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdFruSerial
OBJECT-TYPE
Chassis fan hardware VPD FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Chassis fan hardware VPD manufacturer ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdProductId
OBJECT-TYPE
Chassis fan hardware VPD product ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdSubManufacturerId
OBJECT-TYPE
Chassis fan hardware VPD subsystem manufacturer ID.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdClei
OBJECT-TYPE
Chassis fan hardware VPD Common Language Equipment Identifier (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15OCTET STRINGread-onlydeprecated
chassisFanHardwareVpdHardwareRevisionString
OBJECT-TYPE
Chassis fan hardware VPD hardware revision in string format.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16OCTET STRINGread-onlydeprecated
pmFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.14
pmControllerVPDTable
OBJECT-TYPE
Table of Power Module controller firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.14.1not-accessibledeprecated
pmControllerVPDEntry
OBJECT-TYPE
Power Module controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1not-accessibledeprecated
pmControllerVpdIndex
OBJECT-TYPE
Power Module controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1INTEGERread-onlydeprecated
pmControllerVpdId
OBJECT-TYPE
The numeric Power Module ID.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2INTEGER {powerModule1(1), powerModule2(2), powerModule3(3), powerModule4(4), powerModule5(5), powerModule6(6)}read-onlydeprecated
pmControllerVpdExists
OBJECT-TYPE
Indicates whether the Power Module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
pmControllerVpdRevision
OBJECT-TYPE
The revision of the Power Module controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7OCTET STRINGread-onlydeprecated
inventoryManagementActivityVpdTable
OBJECT-TYPE
Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22not-accessiblemandatory
inventoryManagementActivityVpdEntry
OBJECT-TYPE
System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1not-accessiblemandatory
componentLevelActivityVpdIndex
OBJECT-TYPE
System component level VPD activity log index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.1INTEGERread-onlymandatory
componentLevelActivityVpdFruNumber
OBJECT-TYPE
System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.2OCTET STRINGread-onlymandatory
componentLevelActivityVpdSerialNumber
OBJECT-TYPE
System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.3OCTET STRINGread-onlymandatory
componentLevelActivityVpdManufacturingId
OBJECT-TYPE
System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.4OCTET STRINGread-onlymandatory
componentLevelActivityVpdBayNumber
OBJECT-TYPE
System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.5OCTET STRINGread-onlydeprecated
componentLevelActivityVpdAction
OBJECT-TYPE
System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.9OCTET STRINGread-onlymandatory
componentLevelActivityVpdTimestamp
OBJECT-TYPE
System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.10OCTET STRINGread-onlymandatory
componentLevelActivityVpdModuleName
OBJECT-TYPE
The module name which this row is associated with. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.12OCTET STRINGread-onlymandatory
componentLevelActivityVpdTopologyPath
OBJECT-TYPE
The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. The topology path's numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.2.21.22.1.15OCTET STRING (SIZE(0..100))read-onlymandatory
reloadVpdData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.23
reloadAllVpdData
OBJECT-TYPE
Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.1INTEGER {execute(1)}read-writemandatory
reloadFwVpdData
OBJECT-TYPE
Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.2INTEGER {execute(1)}read-writemandatory
reloadHwVpdData
OBJECT-TYPE
Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.3INTEGER {execute(1)}read-writemandatory
reloadMACAddress
OBJECT-TYPE
Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.4INTEGER {execute(1)}read-writemandatory
reloadWwnGuidVpdData
OBJECT-TYPE
Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.5INTEGER {execute(1)}read-writemandatory
airFilter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.22
passiveAirFilter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.22.1
passiveAirFilterStatus
OBJECT-TYPE
Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date.
1.3.6.1.4.1.2.3.51.2.2.22.1.1INTEGER {disabled(0), enabled(1), reset(2)}read-writemandatory
passiveAirFilterMonthFreq
OBJECT-TYPE
The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust.
1.3.6.1.4.1.2.3.51.2.2.22.1.2INTEGER {oneMonth(1), threeMonths(3), sixMonths(6)}read-writemandatory
passiveAirFilterReplaceDate
OBJECT-TYPE
The scheduled replacement date of the air filter.
1.3.6.1.4.1.2.3.51.2.2.22.1.3OCTET STRING (SIZE(0..30))read-onlymandatory
componentInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23
componentInventory
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23.1
componentInventoryTable
OBJECT-TYPE
Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. Also, if a component does not have inventory information or the CMM is not able to read the data from the device, then there will not be a row in this table for the component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1not-accessiblemandatory
componentInventoryEntry
OBJECT-TYPE
Component inventory information.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1not-accessiblemandatory
componentInventoryTopologyPath
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentInventoryInstance
OBJECT-TYPE
The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2INTEGERread-onlymandatory
componentInventoryDescription
OBJECT-TYPE
A short text string describing the particular component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object in this table or the componentXXXXName object of any of the other component tables under the 'components' section of the MIB.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3OCTET STRINGread-onlymandatory
componentInventoryMachineTypeModel
OBJECT-TYPE
The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4OCTET STRINGread-onlymandatory
componentInventoryMachineSerial
OBJECT-TYPE
The machine serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5OCTET STRINGread-onlymandatory
componentInventoryAssetID
OBJECT-TYPE
The asset identifier of this component, typically set by some other authority than the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6OCTET STRINGread-onlymandatory
componentInventoryPartNumber
OBJECT-TYPE
The part number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7OCTET STRINGread-onlymandatory
componentInventoryFRUNumber
OBJECT-TYPE
The Field Replaceable Unit (FRU) number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8OCTET STRINGread-onlymandatory
componentInventoryFRUSerialNumber
OBJECT-TYPE
The Field Replaceable Unit (FRU) serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9OCTET STRINGread-onlymandatory
componentInventoryManufacture
OBJECT-TYPE
The text description of the manufacturer of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10OCTET STRINGread-onlymandatory
componentInventoryHardwareRevision
OBJECT-TYPE
The hardware revision number of the this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11OCTET STRINGread-onlymandatory
componentInventoryManufactureDate
OBJECT-TYPE
The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12OCTET STRINGread-onlymandatory
componentInventoryUUID
OBJECT-TYPE
The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13OCTET STRINGread-onlymandatory
componentInventoryProductID
OBJECT-TYPE
The product identifier of the component assigned by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14OCTET STRINGread-onlymandatory
componentInventorySubManufactureID
OBJECT-TYPE
The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15OCTET STRINGread-onlymandatory
componentInventoryCLEI
OBJECT-TYPE
The Common Language Equipment Identifier (CLEI) of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16OCTET STRINGread-onlymandatory
componentInventoryAssetTag
OBJECT-TYPE
The asset tag of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17OCTET STRINGread-onlymandatory
componentInventorySpeed
OBJECT-TYPE
A speed designation for the component, for example, processor speed.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18OCTET STRINGread-onlymandatory
componentInventoryIdentifier
OBJECT-TYPE
A unique identifier assigned by the manufacturer to the component, for example, a processor ID.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19OCTET STRINGread-onlymandatory
componentInventorySize
OBJECT-TYPE
A size designation for the component, for example, a memory DIMM size or hard drive capacity.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20INTEGERread-onlymandatory
componentInventoryMemoryType
OBJECT-TYPE
The architecture specification of a memory device.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21INTEGER {fpmdram(1), edo(2), edodram(3), sdram(4), multiplexedram(5), ddrsgram(6), ddrsdram(7), ddr2sdrm(8), ddr3sdram(11)}read-onlymandatory
componentInventoryProductName
OBJECT-TYPE
The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22OCTET STRINGread-onlymandatory
componentInventoryProductVersion
OBJECT-TYPE
The product version assigned by the manufacturer for this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23OCTET STRINGread-onlymandatory
componentInventoryProcessorType
OBJECT-TYPE
The type designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24INTEGER {other(1), unknown(2), central(3), math(4), dsp(5), video(6)}read-onlymandatory
componentInventoryProcessorFamily
OBJECT-TYPE
The family designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25OCTET STRINGread-onlymandatory
componentInventoryProcessorCores
OBJECT-TYPE
The number of cores present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26OCTET STRINGread-onlymandatory
componentInventoryProcessorThreads
OBJECT-TYPE
The number of threads present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27OCTET STRINGread-onlymandatory
componentInventoryProcessorL1DCache
OBJECT-TYPE
The level 1 data cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28OCTET STRINGread-onlymandatory
componentInventoryProcessorL1ICache
OBJECT-TYPE
The level 1 instruction cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29OCTET STRINGread-onlymandatory
componentInventoryProcessorL2Cache
OBJECT-TYPE
The level 2 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30OCTET STRINGread-onlymandatory
componentInventoryProcessorL3Cache
OBJECT-TYPE
The level 3 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31OCTET STRINGread-onlymandatory
componentInventoryProcessorVoltage
OBJECT-TYPE
The voltage rating for a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32OCTET STRINGread-onlymandatory
componentInventoryProcessorExtClock
OBJECT-TYPE
The external clock speed of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33OCTET STRINGread-onlymandatory
componentInventoryProcessorDataWidth
OBJECT-TYPE
The maximum data bus width capability of a processor component, expressed typically in bits.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34OCTET STRINGread-onlymandatory
componentInventoryManufactureIDNum
OBJECT-TYPE
The identification number assigned for the component by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35INTEGERread-onlymandatory
componentInventoryGlobalID
OBJECT-TYPE
The global identifier (GLID) of this component. This ID is a unique identifier for the CMM chassis (midplane), set by the manufacturer. This ID and the associated inventory is passed back to IBM via the Electronic Service Agent and the Call Home feature. This ID and the accompanying chassis inventory will be stored and retained resulting in a configuration/change history file of the inventory for a chassis associated with a particular GLID. This ID can be used by a customer to identify and categorize all the content that resides within a chassis, much like a physical serial number is associated with a single box server.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.41OCTET STRINGread-onlymandatory
componentInventoryTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentInventoryTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.23.1.2INTEGERread-onlymandatory
componentFirmware
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23.2
componentFirmwareTable
OBJECT-TYPE
Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry.
1.3.6.1.4.1.2.3.51.2.2.23.2.1not-accessiblemandatory
componentFirmwareEntry
OBJECT-TYPE
Component firmware information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1not-accessiblemandatory
componentFirmwareTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentFirmwareIndex
OBJECT-TYPE
Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2INTEGERread-onlymandatory
componentFirmwareComponentInstance
OBJECT-TYPE
The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3INTEGERread-onlymandatory
componentFirmwareComponentDescription
OBJECT-TYPE
A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4OCTET STRINGread-onlymandatory
componentFirmwareType
OBJECT-TYPE
A text description of the type of firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5OCTET STRINGread-onlymandatory
componentFirmwareBuildID
OBJECT-TYPE
A text description of the build identifier for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6OCTET STRINGread-onlymandatory
componentFirmwareReleaseDate
OBJECT-TYPE
A text description of the release date for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7OCTET STRINGread-onlymandatory
componentFirmwareFilename
OBJECT-TYPE
A text description of the filename of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8OCTET STRINGread-onlymandatory
componentFirmwareRevision
OBJECT-TYPE
A text description of the revision level of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9OCTET STRINGread-onlymandatory
componentFirmwareRevisionMajor
OBJECT-TYPE
A numeric identifier of the revision major number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10INTEGERread-onlymandatory
componentFirmwareRevisionMinor
OBJECT-TYPE
A numeric identifier of the revision minor number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11INTEGERread-onlymandatory
componentFirmwareLevelStatus
OBJECT-TYPE
The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12OCTET STRINGread-onlymandatory
componentFirmwarePendingBuildID
OBJECT-TYPE
A text description of the build identifier for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13OCTET STRINGread-onlymandatory
componentFirmwarePendingReleaseDate
OBJECT-TYPE
A text description of the release date for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14OCTET STRINGread-onlymandatory
componentFirmwarePendingRevision
OBJECT-TYPE
A text description of the revision level of this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15OCTET STRINGread-onlymandatory
componentFirmwareReleaseLevel
OBJECT-TYPE
A text description of the firmware release level this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.16OCTET STRINGread-onlymandatory
componentFirmwareImageStatus
OBJECT-TYPE
This object indicates whether this firmware image is the active (1) firmware,otherwise this firmware image is inactive (0).
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.17INTEGER {inactive(0), active(1), na(255)}read-onlymandatory
componentFirmwareRole
OBJECT-TYPE
A text description with the firmware image information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.18OCTET STRINGread-onlymandatory
componentFirmwareTypeID
OBJECT-TYPE
Indicates the type of firmware load with a numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20INTEGER {bladeFwBios(1), bladeDiagnostics(2), bladeSysMgmtProcessor(3), bladeFpga(4), bladecKVM(5), bladeMP(6), bladeUEFI(7), bladeDSA(8), switchModuleMainAppl(40), switchModuleMainAppl1(41), switchModuleMainAppl2(42), switchModuleBootROM(43), mgmtModuleMainAppl(61), mgmtModuleMainApplPendingRestart(62), fanController(81), powerSupplyFirmware(91), powerSupplyFanController(92), expansionCardGeneric(101), expansionCardEfi(102), expansionCardFcode(103), expansionCardBios(104), expansionCardMain(105), expansionCardMulti(106), unknown(255)}read-onlymandatory
componentFirmwareTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentFirmwareTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.23.2.2INTEGERread-onlymandatory
nodeFirmwareAnalysisTable
OBJECT-TYPE
Table of firmware levels of installed nodes. This information is grouped by Machine Type/Model and includes two or more nodes with the same Type/Model. This information is intended to be used in determining which components firmware may need upgrade.
1.3.6.1.4.1.2.3.51.2.2.23.2.7not-accessiblemandatory
nodeFirmwareAnalysisEntry
OBJECT-TYPE
Node firmware analysis information.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1not-accessiblemandatory
nodeFirmwareAnalysisIndex
OBJECT-TYPE
The index for the node firmware levels.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.1INTEGERread-onlymandatory
nodeFirmwareAnalysisMachineTypeModel
OBJECT-TYPE
The machine type or model of node firmware.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.2OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisFirmwareType
OBJECT-TYPE
The firmware type.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.3OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisBuildId
OBJECT-TYPE
The firmware build id.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.4OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisReleaseDate
OBJECT-TYPE
The firmware release date.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.5OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisRevisionLevel
OBJECT-TYPE
The firmware revision level.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.6OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisTopology
OBJECT-TYPE
The node topology.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.7OCTET STRINGread-onlymandatory
nodeFirmwareAnalysisDeviceName
OBJECT-TYPE
The node device name.
1.3.6.1.4.1.2.3.51.2.2.23.2.7.1.8OCTET STRINGread-onlymandatory
smFirmwareAnalysisTable
OBJECT-TYPE
Table of firmware levels of installed IOMs. This information is grouped by Product Id and includes two or more IOMs with the same product id. This information is intended to be used in determining which components firmware may need upgrade.
1.3.6.1.4.1.2.3.51.2.2.23.2.11not-accessiblemandatory
smFirmwareAnalysisEntry
OBJECT-TYPE
IOM firmware analysis information.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1not-accessiblemandatory
smFirmwareAnalysisIndex
OBJECT-TYPE
The index for the IOM firmware levels.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.1INTEGERread-onlymandatory
smFirmwareAnalysisProductId
OBJECT-TYPE
The IOM product id.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.2OCTET STRINGread-onlymandatory
smFirmwareAnalysisProductName
OBJECT-TYPE
The IOM product name.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.3OCTET STRINGread-onlymandatory
smFirmwareAnalysisFirmwareType
OBJECT-TYPE
The IOM firmware type.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.4OCTET STRINGread-onlymandatory
smFirmwareAnalysisFirmwareVersion
OBJECT-TYPE
The IOM firmware version.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.5OCTET STRINGread-onlymandatory
smFirmwareAnalysisReleaseDate
OBJECT-TYPE
The IOM release date.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.6OCTET STRINGread-onlymandatory
smFirmwareAnalysisTopology
OBJECT-TYPE
The IOM topology.
1.3.6.1.4.1.2.3.51.2.2.23.2.11.1.7OCTET STRINGread-onlymandatory
componentInventoryReady
OBJECT-TYPE
When a blade management controller, switch or the MM is reset, the inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades and switches have completed initialization and the inventory information has been provided to the MM. Note that due to components that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout A more granular, per-blade status is available via the bladeSystemStatusTable
1.3.6.1.4.1.2.3.51.2.2.23.3INTEGER {notReady(0), ready(1)}read-onlymandatory
componentDriveTable
OBJECT-TYPE
Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table.
1.3.6.1.4.1.2.3.51.2.2.23.10not-accessiblemandatory
componentDriveEntry
OBJECT-TYPE
Component drive information.
1.3.6.1.4.1.2.3.51.2.2.23.10.1not-accessiblemandatory
componentDriveTopologyPath
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card
1.3.6.1.4.1.2.3.51.2.2.23.10.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentDriveDescription
OBJECT-TYPE
A short text string describing the particular drive on the component.
1.3.6.1.4.1.2.3.51.2.2.23.10.1.2OCTET STRINGread-onlymandatory
componentDriveTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentDriveTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.2.23.11INTEGERread-onlymandatory
licenseKeyInfo
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.30
licenseKeyInfoTable
OBJECT-TYPE
Table of license key information.
1.3.6.1.4.1.2.3.51.2.2.30.1not-accessiblemandatory
licenseKeyInfoEntry
OBJECT-TYPE
License key information entry.
1.3.6.1.4.1.2.3.51.2.2.30.1.1not-accessiblemandatory
licenseKeyComponentIndex
OBJECT-TYPE
License key component table index.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.1INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14), switchModule1(41), switchModule2(42), switchModule3(43), switchModule4(44)}read-onlymandatory
licenseKeyIndex
OBJECT-TYPE
The license key index for the chassis component.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.2INTEGER (1..255)read-onlymandatory
licenseKeyDescription
OBJECT-TYPE
The description for a license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.3OCTET STRINGread-onlymandatory
licenseKeyTimestamp
OBJECT-TYPE
The date and time of this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.4OCTET STRINGread-onlymandatory
licenseKeyLicenseID
OBJECT-TYPE
The unique identifier for this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.5OCTET STRINGread-onlymandatory
licenseKeyOtherInfo
OBJECT-TYPE
Any other information related to this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.6OCTET STRINGread-onlymandatory
licenseKeyStatus
OBJECT-TYPE
The current status of this license key.
1.3.6.1.4.1.2.3.51.2.2.30.1.1.7INTEGER {unknown(0), valid(1), invalid(2), expired(3), usageExceeded(4), notApplicable(99)}read-onlymandatory
chassisLicenseKeyTable
OBJECT-TYPE
Table of chassis license key information.
1.3.6.1.4.1.2.3.51.2.2.30.5not-accessiblemandatory
chassisLicenseKeyEntry
OBJECT-TYPE
Chassis License key information entry.
1.3.6.1.4.1.2.3.51.2.2.30.5.1not-accessiblemandatory
chassisLicenseKeyIndex
OBJECT-TYPE
The key index for the chassis license keys.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.1INTEGER (1..255)read-onlymandatory
chassisLicenseKeyFeature
OBJECT-TYPE
The name of the Feature for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.2OCTET STRINGread-onlymandatory
chassisLicenseKeyFeatureType
OBJECT-TYPE
The Feature Type Code for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.3OCTET STRINGread-onlymandatory
chassisLicenseKeyDescription
OBJECT-TYPE
The description of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.4OCTET STRINGread-onlymandatory
chassisLicenseKeySystem
OBJECT-TYPE
System information for the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.5OCTET STRINGread-onlymandatory
chassisLicenseKeyLicenseID
OBJECT-TYPE
Identification of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.6OCTET STRINGread-onlymandatory
chassisLicenseKeyValidation
OBJECT-TYPE
Validation of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.7OCTET STRINGread-onlymandatory
chassisLicenseKeyStatus
OBJECT-TYPE
The current status of the license key.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.8INTEGER {valid(0), validatingKey(1), invalidMTSN(2), invalidMAC(3), signatureValidationFailed(4), keyExpired(5), usageExceeded(6), validateElsewhere(7), notApplicable(8)}read-onlymandatory
chassisLicenseKeyTimeLimit
OBJECT-TYPE
Date and Time (GMT) when license expires.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.9OCTET STRINGread-onlymandatory
chassisLicenseKeyUsageLimit
OBJECT-TYPE
Number of times remaining for license usage. A negative value indicates that there is no Usage Limit for the license.
1.3.6.1.4.1.2.3.51.2.2.30.5.1.10INTEGERread-onlymandatory
errorLogs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.3
eventLog
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.3.4
readEventLogTable
OBJECT-TYPE
Table of event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.2not-accessiblemandatory
readEventLogEntry
OBJECT-TYPE
Event log table entry
1.3.6.1.4.1.2.3.51.2.3.4.2.1not-accessiblemandatory
readEventLogIndex
OBJECT-TYPE
The event log index number.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.1INTEGERread-onlymandatory
readEventLogString
OBJECT-TYPE
A string of data detailing an event.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.2OCTET STRINGread-onlymandatory
clearEventLog
OBJECT-TYPE
Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.3INTEGER {execute(1)}read-writemandatory
monitorLogStateEvents
OBJECT-TYPE
If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out.
1.3.6.1.4.1.2.3.51.2.3.4.4INTEGER {disabled(0), enabled(1)}read-writemandatory
readEnhancedEventLogTable
OBJECT-TYPE
Table of enhanced event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.6not-accessiblemandatory
readEnhancedEventLogEntry
OBJECT-TYPE
Enhaced Event log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.6.1not-accessiblemandatory
readEnhancedEventLogNumber
OBJECT-TYPE
The event log number for the enhanced event log.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.1Unsigned32 (0..4294967295)read-onlymandatory
readEnhancedEventLogAttribute
OBJECT-TYPE
A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.2OCTET STRINGread-onlymandatory
readEnhancedEventLogMessage
OBJECT-TYPE
A string of data detailing an event log message.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.3OCTET STRINGread-onlymandatory
readEnhancedEventLogSequenceNum
OBJECT-TYPE
The sequence number for the enhanced event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.4Unsigned32 (0..4294967295)read-onlymandatory
readAuditLogTable
OBJECT-TYPE
Table of audit log entry information. Audit log includes the logs whose source is 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.10not-accessiblemandatory
readAuditLogEntry
OBJECT-TYPE
Audit log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.10.1not-accessiblemandatory
readAuditLogNumber
OBJECT-TYPE
The audit log number.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.1Unsigned32 (0..4294967295)read-onlymandatory
readAuditLogAttribute
OBJECT-TYPE
A string of data detailing an audit eventlog's attribute.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.2OCTET STRINGread-onlymandatory
readAuditLogMessage
OBJECT-TYPE
A string of data detailing an audit event log message.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.3OCTET STRINGread-onlymandatory
readAuditLogSequenceNum
OBJECT-TYPE
The sequence number for the audit event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.4Unsigned32 (0..4294967295)read-onlymandatory
clearAuditLog
OBJECT-TYPE
Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.11INTEGER {execute(1)}read-writemandatory
readSystemLogTable
OBJECT-TYPE
Table of system log entry information. System log includes the logs whose source is other than 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.12not-accessiblemandatory
readSystemLogEntry
OBJECT-TYPE
System log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.12.1not-accessiblemandatory
readSystemLogNumber
OBJECT-TYPE
The system log index number.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.1Unsigned32 (0..4294967295)read-onlymandatory
readSystemLogAttribute
OBJECT-TYPE
A string of data detailing an system event log's attribute.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.2OCTET STRINGread-onlymandatory
readSystemLogMessage
OBJECT-TYPE
A string of data detailing an system event log message.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.3OCTET STRINGread-onlymandatory
readSystemLogSequenceNum
OBJECT-TYPE
The sequence number for the system event log. This number is the next sequence number when this event record was create. This number continues to grow, even if this event log is cleared, until it reaches the maximum value of 4294967295. The next sequence number following the maximum value is 1.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.4Unsigned32 (0..4294967295)read-onlymandatory
clearSystemLog
OBJECT-TYPE
Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.13INTEGER {execute(1)}read-writemandatory
readEventLogAuxTable
OBJECT-TYPE
Table of system log entry auxiliary information.
1.3.6.1.4.1.2.3.51.2.3.4.14not-accessiblemandatory
readEventLogAuxEntry
OBJECT-TYPE
Event log auxiliary table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.14.1not-accessiblemandatory
readEventLogAuxNumber
OBJECT-TYPE
The system log auxiliary index number. To relate this information to the system log, match Sequence number of this entry to the Sequence number of the system log entry.
1.3.6.1.4.1.2.3.51.2.3.4.14.1.1INTEGERread-onlymandatory
readEventLogAuxSequenceNum
OBJECT-TYPE
The sequence number for the system event log that contains this Auxiliary information. Value is from 1 through 4294967295 and then wraps.
1.3.6.1.4.1.2.3.51.2.3.4.14.1.2Unsigned32 (0..4294967295)read-onlymandatory
readEventLogAuxMessage
OBJECT-TYPE
A string of data detailing the auxiliary information from the log event.
1.3.6.1.4.1.2.3.51.2.3.4.14.1.3OCTET STRINGread-onlymandatory
configureSP
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4
remoteAccessConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1
generalRemoteCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1
remoteAlertRetryDelay
OBJECT-TYPE
Number in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.2.4.1.1.3INTEGER {oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)}read-writemandatory
remoteAlertRetryCount
OBJECT-TYPE
Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.2.3.51.2.4.1.1.4INTEGER {noretry(0), retry1(1), retry2(2), retry3(3), retry4(4), retry5(5), retry6(6), retry7(7), retry8(8)}read-writemandatory
userAuthenticationMethod
OBJECT-TYPE
Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified.
1.3.6.1.4.1.2.3.51.2.4.1.1.7INTEGER {localOnly(0), ldapOnly(1), localFirstThenLdap(2), ldapFirstThenLocal(3)}read-writemandatory
maxSessionsPerLDAPUser
OBJECT-TYPE
The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20.
1.3.6.1.4.1.2.3.51.2.4.1.1.9INTEGERread-writemandatory
authenticationLoggingTimeout
OBJECT-TYPE
Use this option to set how long, in seconds, MM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events.
1.3.6.1.4.1.2.3.51.2.4.1.1.10INTEGER {logAll(0), fiveSeconds(1), thirtySeconds(2), oneMinute(3), fiveMinutes(4), tenMinutes(5), thirtyMinutes(6), oneHour(7), twelveHours(8), oneDay(9), logNone(255)}read-writemandatory
trackingIP
OBJECT-TYPE
This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'.
1.3.6.1.4.1.2.3.51.2.4.1.1.11INTEGER {disable(0), enable(1)}read-writemandatory
accountSecurityManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1.20
accountSecurityLevel
OBJECT-TYPE
The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.1INTEGER {legacy(0), high(1), custom(2)}read-writemandatory
customSecuritySettings
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2
passwordExpirationPeriod
OBJECT-TYPE
The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2INTEGERread-writemandatory
defaultAdminPasswordExpired
OBJECT-TYPE
If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3INTEGER {disabled(0), enabled(1)}read-writemandatory
minimumPasswordReuseCycle
OBJECT-TYPE
The number of unique passwords a user must choose before reusing a password. The default value is none.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4INTEGER {none(0), onePassword(1), twoPasswords(2), threePasswords(3), fourPasswords(4), fivePasswords(5)}read-writemandatory
complexPasswordRules
OBJECT-TYPE
If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The complex rules are as follows: must be 8-31 characters must contain at least one number must contain at least one letter cannot contain white space characters cannot be a repeat or reverse of user name no more than 3 of the same characters used consecutively must contain at least 2 of the following combinations: at least one upper case letter at least one lower case letter at least one special character Password and password confirm values must match If disabled, the lagacy rules are: must be 5-31 characters must contain at least one number must contain at least one letter cannot contain white space characters Password and password confirm values must match The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5INTEGER {disabled(0), enabled(1)}read-writemandatory
minimumDiffCharsPassword
OBJECT-TYPE
The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0)
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6INTEGER {none(0), oneChar(1), twoChars(2), threeChars(3), fourChars(4), fiveChars(5), sixChars(6), sevenChars(7), eightChars(8), nineChars(9), tenChars(10), elevenChars(11), twelveChars(12), thirteenChars(13), fourteenChars(14), fifteenChars(15)}read-writemandatory
changePasswordFirstAccess
OBJECT-TYPE
If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7INTEGER {disabled(0), enabled(1)}read-writemandatory
inactivityAlertPeriod
OBJECT-TYPE
The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8INTEGERread-writemandatory
inactivityAlertDisablePeriod
OBJECT-TYPE
The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9INTEGERread-writemandatory
lockoutPeriod
OBJECT-TYPE
The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10INTEGERread-writemandatory
maxLoginFailures
OBJECT-TYPE
The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11INTEGER {none(0), oneTime(1), twoTimes(2), threeTimes(3), fourTimes(4), fiveTimes(5), sixTimes(6), sevenTimes(7), eightTimes(8), nineTimes(9), tenTimes(10)}read-writemandatory
passwordChangeInterval
OBJECT-TYPE
A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12INTEGERread-writemandatory
serialPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.2
portBaud
OBJECT-TYPE
Baud rate for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.1INTEGER {baud2400(0), baud4800(1), baud9600(3), baud19200(7), baud38400(15), baud57600(23), baud115200(47)}read-writemandatory
portParity
OBJECT-TYPE
Parity setting for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.2INTEGER {none(0), odd(1), even(3), mark(5), space(7)}read-writemandatory
portStopBits
OBJECT-TYPE
Number of stop bits for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.3INTEGER {oneStopbit(0), twoOrOnePtFive(1)}read-writemandatory
remoteAlertIds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.3
remoteAlertIdsTable
OBJECT-TYPE
Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients.
1.3.6.1.4.1.2.3.51.2.4.1.3.1not-accessiblemandatory
remoteAlertIdsEntry
OBJECT-TYPE
Remote alert entries.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1not-accessiblemandatory
remoteAlertIdEntryIndex
OBJECT-TYPE
Index for remote alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1INTEGERread-onlymandatory
remoteAlertIdEntryStatus
OBJECT-TYPE
Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2INTEGER {invalid(0), disabledAndValid(1), enabledAndValid(2)}read-writemandatory
remoteAlertIdEntryIpOrHostAddress
OBJECT-TYPE
A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3OCTET STRING (SIZE(0..50))read-writemandatory
remoteAlertIdEntryTextDescription
OBJECT-TYPE
A null terminated string that contains a text description of this entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4OCTET STRING (SIZE(0..50))read-writemandatory
remoteAlertIdEntryNotificationType
OBJECT-TYPE
Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5INTEGER {unknown(0), snmpOverLan(4), emailOverLan(5)}read-writemandatory
remoteAlertIdEmailAddr
OBJECT-TYPE
A null terminated string that contains an E-Mail Address. For example, 'xyz@us.ibm.com'. Used only for an E-mail over LAN notification type.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9OCTET STRING (SIZE(0..64))read-writemandatory
remoteAlertIdEntrySelectiveAlert
OBJECT-TYPE
Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13INTEGER {critOnlyAlerts(0), allAlerts(1)}read-writemandatory
generateTestAlert
OBJECT-TYPE
Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.3.30INTEGER {execute(1)}read-writemandatory
remoteAccessIds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.4
remoteAccessIdsTable
OBJECT-TYPE
Table of remote access profiles. This table lets you to configure all login profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice.
1.3.6.1.4.1.2.3.51.2.4.1.4.1not-accessiblemandatory
remoteAccessIdsEntry
OBJECT-TYPE
Remote access entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1not-accessiblemandatory
remoteAccessIdEntryIndex
OBJECT-TYPE
Index for Remote access entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1INTEGER (0..255)read-onlymandatory
remoteAccessIdEntryUserId
OBJECT-TYPE
Remote access entry null terminated string that contains the userid. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2OCTET STRING (SIZE(0..33))read-writemandatory
remoteAccessIdEntryPassword
OBJECT-TYPE
Remote access password. The password rules are dictated by a combination of the chassis security policy setting (securityPolicySetting) and the user account security level setting (accountSecurityLevel). Refer to object complexPasswordRules to understand the requirements. NOTE: Value returned by the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3OCTET STRING (SIZE(0..17))read-writemandatory
remoteAccessIdEntryPermgroups
OBJECT-TYPE
A list of permission groups for this userid, delmited with a '|'
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10OCTET STRINGread-writemandatory
remoteAccessIdEntryLoggedIn
OBJECT-TYPE
Indicates if user is currently logged in or not.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryLastLogin
OBJECT-TYPE
Timestamp for the last successful login by the user.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12OCTET STRINGread-onlymandatory
remoteAccessIdEntryPwdCompliant
OBJECT-TYPE
Indicates if user complies with all of the password rules currently in effect.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryPwdExp
OBJECT-TYPE
The number of days until the user's current password expires.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14OCTET STRINGread-onlymandatory
remoteAccessIdEntryDormant
OBJECT-TYPE
Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryState
OBJECT-TYPE
Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16INTEGER {disabled(0), active(1), locked(2)}read-onlymandatory
remoteAccessIdEntryAction
OBJECT-TYPE
Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17INTEGER {disable(0), enable(1), unlock(2), notApplicable(255)}read-writemandatory
remoteAccessIdEntrySessionCount
OBJECT-TYPE
The number of sessions the user is currently logged in to.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18INTEGERread-onlymandatory
remoteAccessIdEntryMaxSessions
OBJECT-TYPE
The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19INTEGERread-writemandatory
remoteAccessIdEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table remoteAccessIdEntryStatus = createRequest 2. Set remoteAccessId as required. The remoteAccessIdUserId and the remoteAccessIdPassword must be set before the entry becomes valid. To set the remoteAccessIdsEntryPermgroups or remoteAccessIdsEntryMaxSessions before the entry is valid, set these fields before both the password and userId are set. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.20EntryStatusread-writemandatory
remoteAccessIdEntryIPMIProvisioned
OBJECT-TYPE
Indicates if the user has been provisioned as an IPMI account. If this is user is provisioned as an IPMI account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for IPMI provisioning, setting the value to yes will return an error. When provisioning an IPMI account by setting this object to yes(1), the SNMPv3 account is also automatically provisioned.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.21INTEGER {no(0), yes(1)}read-writemandatory
remoteAccessIdEntrySNMPv3Provisioned
OBJECT-TYPE
Indicates if the user has been provisioned as an SNMPv3 account. If this is user is provisioned as an SNMPv3 account, the nodes (scope) and authorities will be determined by the scope and authorities of the permission groups to which this user belongs. These can be seen in the remoteAccessRBSscopeTable and remoteAccessRBSroleTable for the permission groups to which this user is assigned. If the userid is longer than 16 characters or there are more than 12 user accounts enabled for SNMPv3 provisioning, setting the value to yes will return an error. When provisioning a SNMPv3 account by setting this object to yes(1), the IPMI account is also automatically provisioned.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.22INTEGER {no(0), yes(1)}read-writemandatory
remoteAccessRBSroleTable
OBJECT-TYPE
Table of RBS User Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.3not-accessiblemandatory
remoteAccessRBSroleEntry
OBJECT-TYPE
User Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1not-accessiblemandatory
roleIndex
OBJECT-TYPE
Index for RBS User Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1INTEGER (0..255)read-onlymandatory
roleId
OBJECT-TYPE
Remote access RBS role entry null terminated string that contains the permission group ID. It must not be a duplicate of any previously configured ones. This field is only allowed to be set when the entry status is under creation.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2OCTET STRING (SIZE(0..63))read-writemandatory
rbsSupervisor
OBJECT-TYPE
User has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsOperator
OBJECT-TYPE
User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisOperator
OBJECT-TYPE
User has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisAccountManagement
OBJECT-TYPE
User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisLogManagement
OBJECT-TYPE
User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisConfiguration
OBJECT-TYPE
User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisAdministration
OBJECT-TYPE
User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeOperator
OBJECT-TYPE
User has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeRemotePresence
OBJECT-TYPE
User has ability to access the blades remote console. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeConfiguration
OBJECT-TYPE
User can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeAdministration
OBJECT-TYPE
User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleOperator
OBJECT-TYPE
User has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleConfiguration
OBJECT-TYPE
User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleAdministration
OBJECT-TYPE
User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table rbsEntryStatus = createRequest 2. Set roleId as required. Only one row will be allowed to be underCreation at one time, and it must have the next index in the table. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.23EntryStatusread-writemandatory
remoteAccessRBSscopeTable
OBJECT-TYPE
Table of RBS User Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.4not-accessiblemandatory
remoteAccessRBSscopeEntry
OBJECT-TYPE
User Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1not-accessiblemandatory
scopeIndex
OBJECT-TYPE
Index for RBS User Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1INTEGER (0..255)read-onlymandatory
scopeId
OBJECT-TYPE
Remote access RBS scope entry null terminated string that contains the permission group ID.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2OCTET STRING (SIZE(0..63))read-onlymandatory
rbsChassis
OBJECT-TYPE
User has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade1
OBJECT-TYPE
User has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade2
OBJECT-TYPE
User has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade3
OBJECT-TYPE
User has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade4
OBJECT-TYPE
User has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade5
OBJECT-TYPE
User has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade6
OBJECT-TYPE
User has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade7
OBJECT-TYPE
User has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade8
OBJECT-TYPE
User has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade9
OBJECT-TYPE
User has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade10
OBJECT-TYPE
User has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade11
OBJECT-TYPE
User has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade12
OBJECT-TYPE
User has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade13
OBJECT-TYPE
User has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade14
OBJECT-TYPE
User has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch1
OBJECT-TYPE
User has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch2
OBJECT-TYPE
User has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch3
OBJECT-TYPE
User has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch4
OBJECT-TYPE
User has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch5
OBJECT-TYPE
User has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch6
OBJECT-TYPE
User has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch7
OBJECT-TYPE
User has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch8
OBJECT-TYPE
User has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch9
OBJECT-TYPE
User has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch10
OBJECT-TYPE
User has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27INTEGER {disabled(0), enabled(1)}read-writemandatory
cmmCentralManagerIPMISNMPv3
OBJECT-TYPE
Indicates whether CMM is the central manager of the IPMI and SNMPv3 accounts. For a write, it can only be set to enabled. Once the CMM state is enabled, it can only be cleared by doing a reset to defaults. WARNING: Enabling CMM IPMI/SNMPv3 user account management will cause all presently existing IPMI/SNMPv3 user accounts on nodes to be overwritten. Please be sure to save any existing node IPMI/SNMPv3 account information before proceeding.
1.3.6.1.4.1.2.3.51.2.4.1.4.9INTEGER {disabled(0), enabled(1)}read-writemandatory
userInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.5
cli
OBJECT-TYPE
Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.1INTEGER {disabled(0), telnet-only(1), ssh-only(2), enabled(3)}read-writemandatory
snmp
OBJECT-TYPE
Enable/Disable SNMP v1 and v3 access to the MM. The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.2INTEGER {disabled(0), v1-only(1), v3-only(2), enabled(3)}read-writemandatory
tcm
OBJECT-TYPE
Enable/Disable TCP command mode (TCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode.
1.3.6.1.4.1.2.3.51.2.4.1.5.3INTEGER (0..20)read-writemandatory
web
OBJECT-TYPE
Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser.
1.3.6.1.4.1.2.3.51.2.4.1.5.4INTEGER {disabled(0), enabled(1)}read-writemandatory
stcm
OBJECT-TYPE
Enable/Disable secure TCP command mode (STCM) access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.1.5.5INTEGER (0..20)read-writemandatory
mmSshClientAuth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.6
mmSshClientAuthPubKeyTable
OBJECT-TYPE
A table that contains client authentication public key information.
1.3.6.1.4.1.2.3.51.2.4.1.6.1not-accessiblemandatory
mmSshClientAuthPubKeyEntry
OBJECT-TYPE
A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1not-accessiblemandatory
mmSshClientAuthRemoteAccessIdIndex
OBJECT-TYPE
The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1INTEGERread-onlymandatory
mmSshClientAuthPubKeyIndex
OBJECT-TYPE
The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2INTEGERread-onlymandatory
mmSshClientAuthPubKeyType
OBJECT-TYPE
The type of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3INTEGER {sshDss(1), sshRsa(2)}read-onlymandatory
mmSshClientAuthPubKeySize
OBJECT-TYPE
The size of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)}read-onlymandatory
mmSshClientAuthPubKeyFingerprint
OBJECT-TYPE
The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5OCTET STRINGread-onlymandatory
mmSshClientAuthPubKeyAcceptFrom
OBJECT-TYPE
This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the MM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyComment
OBJECT-TYPE
This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyAction
OBJECT-TYPE
import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the MM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the MM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8INTEGER {import(1), export(2)}read-writemandatory
mmSshClientAuthPubKeyEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it. Note: only one row may be created at one time.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9EntryStatusread-writemandatory
mmSshClientAuthPubKeyUserId
OBJECT-TYPE
The userid for the key entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.10OCTET STRING (SIZE(0..31))read-onlymandatory
mmSshClientAuthPubKeyUnused
OBJECT-TYPE
The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration.
1.3.6.1.4.1.2.3.51.2.4.1.6.2INTEGERread-onlymandatory
mmSshClientAuthPubKeyTftpServer
OBJECT-TYPE
IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2).
1.3.6.1.4.1.2.3.51.2.4.1.6.3OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyFileName
OBJECT-TYPE
File name on the TFTP server of an SSH client authentication public key.
1.3.6.1.4.1.2.3.51.2.4.1.6.4OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyFileFormat
OBJECT-TYPE
File format of SSH client authentication public key files imported from or exported to the TFTP file server.
1.3.6.1.4.1.2.3.51.2.4.1.6.5INTEGER {openSSH(1), rfc4716(2)}read-writemandatory
groupProfiles
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.7
groupIdsTable
OBJECT-TYPE
Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.1not-accessiblemandatory
groupIdsEntry
OBJECT-TYPE
Group ID entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1not-accessiblemandatory
groupIndex
OBJECT-TYPE
Index for Group IDs entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1INTEGER (0..255)read-onlymandatory
groupId
OBJECT-TYPE
Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2OCTET STRING (SIZE(0..16))read-writemandatory
groupRole
OBJECT-TYPE
Group Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3OCTET STRINGread-onlymandatory
groupEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9EntryStatusread-writemandatory
groupRBSroleTable
OBJECT-TYPE
Table of Group Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.2not-accessiblemandatory
groupRBSroleEntry
OBJECT-TYPE
Group Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1not-accessiblemandatory
groupRBSroleIndex
OBJECT-TYPE
Index for Group Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1INTEGER (0..255)read-onlymandatory
groupRBSroleId
OBJECT-TYPE
Group ID
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
groupRBSSupervisor
OBJECT-TYPE
Group has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSOperator
OBJECT-TYPE
Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisOperator
OBJECT-TYPE
Group has ability to browse status and properties of chassis components (MM, chassis fans, midplane, power modules). Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisAccountManagement
OBJECT-TYPE
Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisLogManagement
OBJECT-TYPE
Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisConfiguration
OBJECT-TYPE
Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisAdministration
OBJECT-TYPE
Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeOperator
OBJECT-TYPE
Group has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeRemotePresence
OBJECT-TYPE
Group has ability to access the blade remote console The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeConfiguration
OBJECT-TYPE
Group can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeAdministration
OBJECT-TYPE
Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleOperator
OBJECT-TYPE
Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleConfiguration
OBJECT-TYPE
Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleAdministration
OBJECT-TYPE
Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSscopeTable
OBJECT-TYPE
Table of Group Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.3not-accessiblemandatory
groupRBSscopeEntry
OBJECT-TYPE
Group Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1not-accessiblemandatory
groupRBSscopeIndex
OBJECT-TYPE
Index for Group Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1INTEGER (0..255)read-onlymandatory
groupRBSscopeId
OBJECT-TYPE
Group ID
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
groupRBSChassis
OBJECT-TYPE
Group has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade1
OBJECT-TYPE
Group has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade2
OBJECT-TYPE
Group has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade3
OBJECT-TYPE
Group has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade4
OBJECT-TYPE
Group has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade5
OBJECT-TYPE
Group has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade6
OBJECT-TYPE
Group has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade7
OBJECT-TYPE
Group has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade8
OBJECT-TYPE
Group has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade9
OBJECT-TYPE
Group has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade10
OBJECT-TYPE
Group has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade11
OBJECT-TYPE
Group has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade12
OBJECT-TYPE
Group has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade13
OBJECT-TYPE
Group has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade14
OBJECT-TYPE
Group has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch1
OBJECT-TYPE
Group has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch2
OBJECT-TYPE
Group has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch3
OBJECT-TYPE
Group has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch4
OBJECT-TYPE
Group has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch5
OBJECT-TYPE
Group has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch6
OBJECT-TYPE
Group has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch7
OBJECT-TYPE
Group has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch8
OBJECT-TYPE
Group has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch9
OBJECT-TYPE
Group has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch10
OBJECT-TYPE
Group has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlerts
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2
remoteAlertsCrit
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.1
critPower
OBJECT-TYPE
Generate an alert if any of the system power supplies fail.
1.3.6.1.4.1.2.3.51.2.4.2.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
critBlade
OBJECT-TYPE
Generate an alert for any critical error condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
critIO
OBJECT-TYPE
Generate an alert for any critical error condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
critStorage
OBJECT-TYPE
Generate an alert for any critical error condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
critChassis
OBJECT-TYPE
Generate an alert for any critical error condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
critFan
OBJECT-TYPE
Generate an alert for any critical error condition on cooling devices.
1.3.6.1.4.1.2.3.51.2.4.2.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlertsNonCrit
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.2
warnLogFull
OBJECT-TYPE
Generate an alert if the system log reaches 100% full.
1.3.6.1.4.1.2.3.51.2.4.2.2.10INTEGER {disabled(0), enabled(1)}read-writemandatory
warnBlade
OBJECT-TYPE
Generate an alert for any warning condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.2.15INTEGER {disabled(0), enabled(1)}read-writemandatory
warnIO
OBJECT-TYPE
Generate an alert for any warning condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.2.16INTEGER {disabled(0), enabled(1)}read-writemandatory
warnStorage
OBJECT-TYPE
Generate an alert for any warning condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.2.17INTEGER {disabled(0), enabled(1)}read-writemandatory
warnPower
OBJECT-TYPE
Generate an alert for any warning condition on power module.
1.3.6.1.4.1.2.3.51.2.4.2.2.18INTEGER {disabled(0), enabled(1)}read-writemandatory
warnChassis
OBJECT-TYPE
Generate an alert for any warning condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.2.19INTEGER {disabled(0), enabled(1)}read-writemandatory
warnFan
OBJECT-TYPE
Generate an alert for any warning condition on cooling devices.
1.3.6.1.4.1.2.3.51.2.4.2.2.20INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlertsSystem
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.3
systemInventory
OBJECT-TYPE
Generate an alert if the a processor blade or media tray is added or removed.
1.3.6.1.4.1.2.3.51.2.4.2.3.10INTEGER {disabled(0), enabled(1)}read-writemandatory
systemLog75PctFull
OBJECT-TYPE
Generate an alert if the system log reaches 75% full.
1.3.6.1.4.1.2.3.51.2.4.2.3.11INTEGER {disabled(0), enabled(1)}read-writemandatory
networkChangeNotification
OBJECT-TYPE
Generate an alert if the MM has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module.
1.3.6.1.4.1.2.3.51.2.4.2.3.12INTEGER {disabled(0), enabled(1)}read-writemandatory
systemRemoteLogin
OBJECT-TYPE
Generate an alert if the system detects a new user logged in from a remote site.
1.3.6.1.4.1.2.3.51.2.4.2.3.15INTEGER {disabled(0), enabled(1)}read-writemandatory
systemBlade
OBJECT-TYPE
Generate an alert for any informational condition on a blade.
1.3.6.1.4.1.2.3.51.2.4.2.3.16INTEGER {disabled(0), enabled(1)}read-writemandatory
systemIO
OBJECT-TYPE
Generate an alert for any informational condition on I/O module.
1.3.6.1.4.1.2.3.51.2.4.2.3.17INTEGER {disabled(0), enabled(1)}read-writemandatory
systemStorage
OBJECT-TYPE
Generate an alert for any informational condition on a Storage module.
1.3.6.1.4.1.2.3.51.2.4.2.3.18INTEGER {disabled(0), enabled(1)}read-writemandatory
systemPower
OBJECT-TYPE
Generate an alert for any informational condition on power module.
1.3.6.1.4.1.2.3.51.2.4.2.3.19INTEGER {disabled(0), enabled(1)}read-writemandatory
systemChassis
OBJECT-TYPE
Generate an alert for any informational condition on chassis.
1.3.6.1.4.1.2.3.51.2.4.2.3.20INTEGER {disabled(0), enabled(1)}read-writemandatory
systemFan
OBJECT-TYPE
Generate an alert for any informational condition on cooling device.
1.3.6.1.4.1.2.3.51.2.4.2.3.21INTEGER {disabled(0), enabled(1)}read-writemandatory
systemPWRDO
OBJECT-TYPE
Generate an alert for any informational condition on power on and power off.
1.3.6.1.4.1.2.3.51.2.4.2.3.22INTEGER {disabled(0), enabled(1)}read-writemandatory
securitySettings
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.3
trespassWarning
OBJECT-TYPE
If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces.
1.3.6.1.4.1.2.3.51.2.4.3.2INTEGER {disabled(0), enabled(1)}read-writemandatory
trespassWarningDefault
OBJECT-TYPE
Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.3.3INTEGER {execute(1)}read-writemandatory
trespassMessage
OBJECT-TYPE
The value of the trespass warning message.
1.3.6.1.4.1.2.3.51.2.4.3.4OCTET STRING (SIZE(0..1600))read-writemandatory
chassisSecuritySettings
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.3.5
securityPolicySetting
OBJECT-TYPE
Determines chassis security policy. legacy mode(0) or secure mode(1). unknown(255) returned when policy can't be set or determined.
1.3.6.1.4.1.2.3.51.2.4.3.5.1INTEGER {legacy(0), secure(1), unknown(255)}read-writemandatory
securityPolicyState
OBJECT-TYPE
Determines chassis security policy state. If pending(0), check securityPolicyStatusTable for details on actions needed, to make fully active.
1.3.6.1.4.1.2.3.51.2.4.3.5.2INTEGER {active(0), pending(1), unknown(255)}read-onlymandatory
securityPolicyStatusTable
OBJECT-TYPE
Table of pending security policy status.
1.3.6.1.4.1.2.3.51.2.4.3.5.3not-accessiblemandatory
securityPolicyStatusEntry
OBJECT-TYPE
Pending security policy status entry
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1not-accessiblemandatory
securityPolicyStatusIndex
OBJECT-TYPE
Pending Security policy status index.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.1INTEGER (0..128)read-onlymandatory
securityPolicyStatusComponentType
OBJECT-TYPE
Indicates Component type and location with pending security status.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.2INTEGER {system(0), mgmtModule1(1), mgmtModule2(2), blade1(11), blade2(12), blade3(13), blade4(14), blade5(15), blade6(16), blade7(17), blade8(18), blade9(19), blade10(20), blade11(21), blade12(22), blade13(23), blade14(24), switchModule1(31), switchModule2(32), switchModule3(33), switchModule4(34)}read-onlymandatory
securityPolicyStatusBayId
OBJECT-TYPE
Bay location of specific component. NOTE: securityPolicyStatusComponentType enumeration also indicates location.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.3INTEGER (0..14)read-onlymandatory
securityPolicyStatusSummary
OBJECT-TYPE
Summary of pending security status for the component.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.4OCTET STRINGread-onlymandatory
securityPolicyStatusDetails
OBJECT-TYPE
Details of pending security status for the component.
1.3.6.1.4.1.2.3.51.2.4.3.5.3.1.5OCTET STRINGread-onlymandatory
cryptography
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.3.5.10
cryptographySummary
OBJECT-TYPE
The current level and summary description of the cryptographic configuration.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.5OCTET STRINGread-onlymandatory
cryptographyMode
OBJECT-TYPE
The NIST cryptographic mode setting. A successful setting of this object initiates a reboot of the CMM within a few seconds.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.15INTEGER {nistCompatibility(0), nist800131a(1)}read-writemandatory
cryptographyModeDetailsTable
OBJECT-TYPE
A table of information indicating any NIST customization details and any reasons that the CMM cannot transition to the desired NIST mode.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18not-accessiblemandatory
cryptographyModeDetailsEntry
OBJECT-TYPE
Cryptography mode status entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1not-accessiblemandatory
cryptographyModeDetailsIndex
OBJECT-TYPE
Cryptography mode details index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.1INTEGERread-onlymandatory
cryptographyModeDetailsType
OBJECT-TYPE
Indication of what type of message is reported for this entry.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.2INTEGER {customization(0), transition(1)}read-onlymandatory
cryptographyModeDetailsDescription
OBJECT-TYPE
Message containing details for this cryptography entry.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.18.1.3OCTET STRINGread-onlymandatory
cryptographyModeComponentTable
OBJECT-TYPE
A table of information listing any IOMs or nodes that require a firmware update in order for the CMM to transition to the new mode.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20not-accessiblemandatory
cryptographyModeComponentEntry
OBJECT-TYPE
Cryptography mode component entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1not-accessiblemandatory
cryptographyModeComponentIndex
OBJECT-TYPE
Cryptography mode component index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.1INTEGERread-onlymandatory
cryptographyModeComponentId
OBJECT-TYPE
A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.20.1.2OCTET STRINGread-onlymandatory
cryptographicCipher
OBJECT-TYPE
The cryptographic cipher suite setting.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.25INTEGER {legacy(0), tls12serveronly(1), tls12serverclient(2)}read-writemandatory
cryptographyCipherComponentTable
OBJECT-TYPE
A table of information listing any IOMs or nodes that are out of compliance with regards to the cipher suite setting and are therefore preventing the CMM from transitioning to the new cipher mode.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30not-accessiblemandatory
cryptographyCipherComponentEntry
OBJECT-TYPE
Cryptography cipher component entry
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1not-accessiblemandatory
cryptographyCipherComponentIndex
OBJECT-TYPE
Cryptography cipher component index.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.1INTEGERread-onlymandatory
cryptographyCipherComponentId
OBJECT-TYPE
A component identifier for an IOM or node in the form: ts:mm. t(type), s(slot number), mm sub-slot number.
1.3.6.1.4.1.2.3.51.2.4.3.5.10.30.1.2OCTET STRINGread-onlymandatory
cipherStrength
OBJECT-TYPE
Strength level of the NIST signing algorithm for certificate authority. None(0) indicates no signing algorithm has been set. When writing a new value to this object, a result of No Error is returned if the value is valid. However, the new algorithm will be used to create an authority certificate asynchronously. This process may take up to 1 minute to complete. So results for subsequent queries to the object's value may also be delayed while the new certificate is being generated.
1.3.6.1.4.1.2.3.51.2.4.3.5.15INTEGER {none(0), rsa2048SHA1(1), rsa2048SHA256(2)}read-writemandatory
spClock
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.4
spClockDateAndTimeSetting
OBJECT-TYPE
MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59
1.3.6.1.4.1.2.3.51.2.4.4.1OCTET STRINGread-writemandatory
spClockTimezoneSetting
OBJECT-TYPE
MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. For write, the value must be a time zone listed in spClockTimezoneTable. The spClockTimezoneTable lists all valid time zones. Example: To set America's New York time zone, set the value to: 'America/New_York' For read, the value format is <offset>,<DST flag>,<time zone> (<comment>) Example: -4:00,yes,America/New_York (Eastern Time)
1.3.6.1.4.1.2.3.51.2.4.4.2OCTET STRINGread-writemandatory
spClockTimezoneTable
OBJECT-TYPE
Table of all time zones listed in zone.tab file
1.3.6.1.4.1.2.3.51.2.4.4.3not-accessiblemandatory
spClockTimezoneEntry
OBJECT-TYPE
Time zone entry
1.3.6.1.4.1.2.3.51.2.4.4.3.1not-accessiblemandatory
spClockTimezoneIndex
OBJECT-TYPE
Time zone table index.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.1INTEGER (0..1000)read-onlymandatory
spClockTimezoneId
OBJECT-TYPE
Time zone instance id.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.2OCTET STRINGread-onlymandatory
spClockTimezoneCaption
OBJECT-TYPE
Time zone caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.3OCTET STRINGread-onlymandatory
spClockTimezoneDescription
OBJECT-TYPE
Time zone description.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.4OCTET STRINGread-onlymandatory
spClockTimezoneName
OBJECT-TYPE
Time zone name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.5OCTET STRINGread-onlymandatory
spClockTimezoneStandardName
OBJECT-TYPE
Time zone standard name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.6OCTET STRINGread-onlymandatory
spClockTimezoneStandardCaption
OBJECT-TYPE
Time zone standard caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.7OCTET STRINGread-onlymandatory
spClockTimezoneDaylightName
OBJECT-TYPE
Time zone daylight name.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.8OCTET STRINGread-onlymandatory
spClockTimezoneDaylightCaption
OBJECT-TYPE
Time zone daylight caption.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.9OCTET STRINGread-onlymandatory
spClockTimezoneCmmOffset
OBJECT-TYPE
CMM offset.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.10INTEGERread-onlymandatory
spClockTimezoneStandardOffsetMinutes
OBJECT-TYPE
Standard GMT offset in minutes.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.11INTEGERread-onlymandatory
spClockTimezoneStandardDaylightOffsetMinutes
OBJECT-TYPE
Standard GMT offset in minutes.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.12INTEGERread-onlymandatory
spClockTimezoneDaylightDay
OBJECT-TYPE
There are two different interpretations for this field, depending on the value of DaylightDayOfWeek. In one case, DaylightDay defines the day-in-month on which daylight saving time starts. This interpretation is used when the DaylightDayOfWeek is 0. A positive or negative integer is specified to indicate whether the DaylightDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the DaylightMonth and -1 indicates the last day in the DaylightMonth. When DaylightDayOfWeek is not 0, DaylightDay is the day in the month on which daylight saving time starts, as defined in conjunction with DaylightDayOfWeek. For example, if DaylightDay is 15 and DaylightDayOfWeek is Saturday, then daylight saving time starts on the first Saturday on or after the 15th day in the DaylightMonth (that is, the third Saturday in the month). If DaylightDay is 20 and DaylightDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20th day in the DaylightMonth. If DaylightDay is -1 and DaylightDayOfWeek is -Sunday, then this indicates the last Sunday in the month.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.13INTEGER {undefined(255)}read-onlymandatory
spClockTimezoneDaylightDayOfWeek
OBJECT-TYPE
Day of week daylight saving begins.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.14INTEGER {minusSaturday(-7), minusFriday(-6), minusThursday(-5), minusWednesday(-4), minusTuesday(-3), minusMonday(-2), minusSunday(-1), exactDayOfMonth(0), sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), undefined(255)}read-onlymandatory
spClockTimezoneDaylightMonth
OBJECT-TYPE
Month daylight saving begins.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.15INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11), undefined(255)}read-onlymandatory
spClockTimezoneDaylightStandardDay
OBJECT-TYPE
There are two different interpretations for this property, depending on the value of StandardDayOfWeek. In one case, StandardDay defines the day-in-month on which daylight saving time ends. This interpretation is used when the StandardDayOfWeek is 0. A positive or negative integer is specified to indicate whether the StandardDay is calculated from the beginning or the end of the month. For example, 5 indicates the fifth day in the StandardMonth and -1 indicates the last day in the StandardMonth. When StandardDayOfWeek is not 0, StandardDay is the day-in-month on which daylight saving time ends, as defined in conjunction with StandardDayOfWeek. For example, if StandardDay is 15 and StandardDayOfWeek is Saturday, then daylight saving time ends on the first Saturday on or after the 15th day in the StandardMonth (that is, the third Saturday in the month). If StandardDay is 20 and StandardDayOfWeek is -Saturday, then this indicates the first Saturday on or before the 20 th day in the StandardMonth. If StandardDay is -1 and StandardDayOfWeek is -Sunday, then this indicates the last Sunday in the StandardMonth.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.16INTEGER {undefined(255)}read-onlymandatory
spClockTimezoneDaylightStandardDayOfWeek
OBJECT-TYPE
Day of week daylight saving ends.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.17INTEGER {minusSaturday(-7), minusFriday(-6), minusThursday(-5), minusWednesday(-4), minusTuesday(-3), minusMonday(-2), minusSunday(-1), exactDayOfMonth(0), sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), undefined(255)}read-onlymandatory
spClockTimezoneDaylightStandardMonth
OBJECT-TYPE
Month daylight saving ends.
1.3.6.1.4.1.2.3.51.2.4.4.3.1.18INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11), undefined(255)}read-onlymandatory
spClockTimezoneDaylightIntervalInMinutes
OBJECT-TYPE
Interval in minutes (Daylight saving begins).
1.3.6.1.4.1.2.3.51.2.4.4.3.1.19INTEGERread-onlymandatory
spClockTimezoneDaylightStandardInMinutes
OBJECT-TYPE
Interval in minutes (Daylight saving ends).
1.3.6.1.4.1.2.3.51.2.4.4.3.1.20INTEGERread-onlymandatory
spClockTimezoneDaylightStart
OBJECT-TYPE
DST start.
1.3.6.1.4.1.2.3.51.2.4.4.5OCTET STRINGread-onlymandatory
spClockTimezoneDaylightEnd
OBJECT-TYPE
DST end.
1.3.6.1.4.1.2.3.51.2.4.4.6OCTET STRINGread-onlymandatory
spIdentification
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.5
spTxtId
OBJECT-TYPE
Text description of the MM. NOTE: Do not put any 'space characters' at end of the string.
1.3.6.1.4.1.2.3.51.2.4.5.1OCTET STRING (SIZE(0..16))read-writemandatory
networkConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9
networkInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1
extEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.1
extEthernetInterfaceType
OBJECT-TYPE
The type of interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.1OCTET STRING (SIZE(0..16))read-onlymandatory
extEthernetInterfaceHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.3OCTET STRING (SIZE(0..64))read-writemandatory
extEthernetInterfaceIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.4IpAddressread-writemandatory
extEthernetInterfaceDataRate
OBJECT-TYPE
Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.5INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1Gigabit(6)}read-writemandatory
extEthernetInterfaceDuplexSetting
OBJECT-TYPE
Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.6INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)}read-writemandatory
extEthernetInterfaceLAA
OBJECT-TYPE
Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.7OCTET STRING (SIZE(17))read-writemandatory
extEthernetInterfaceDhcpEnabled
OBJECT-TYPE
Disable or enable DHCP on this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.8INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)}read-writemandatory
extEthernetInterfaceGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.9IpAddressread-writemandatory
extEthernetInterfaceBIA
OBJECT-TYPE
Specifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.10OCTET STRING (SIZE(17))read-onlymandatory
extEthernetInterfaceMTU
OBJECT-TYPE
Contains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.13INTEGERread-writemandatory
extEthernetInterfaceSubnetMask
OBJECT-TYPE
Contains the subnet mask for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.14IpAddressread-writemandatory
dhcpEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16
dhcpHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1OCTET STRING (SIZE(0..64))read-onlymandatory
dhcpIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2IpAddressread-onlymandatory
dhcpGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3IpAddressread-onlymandatory
dhcpSubnetMask
OBJECT-TYPE
Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4IpAddressread-onlymandatory
dhcpDomainName
OBJECT-TYPE
Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5OCTET STRING (SIZE(0..64))read-onlymandatory
dhcpDHCPServer
OBJECT-TYPE
Contains the DHCP server IP address used to acquire the DHCP settings.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6IpAddressread-onlymandatory
dhcpPrimaryDNSServer
OBJECT-TYPE
Contains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7IpAddressread-onlymandatory
dhcpSecondaryDNSServer
OBJECT-TYPE
Contains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8IpAddressread-onlymandatory
dhcpTertiaryDNSServer
OBJECT-TYPE
Contains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9IpAddressread-onlymandatory
extEthernetInterfaceFloatingIPAddress
OBJECT-TYPE
Contains the floating IP address for the external ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.22IpAddressread-writemandatory
standbyExtEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.3
standbyExtEthernetInterfaceType
OBJECT-TYPE
The type of interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.1OCTET STRING (SIZE(0..16))read-onlymandatory
standbyExtEthernetInterfaceHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.3OCTET STRING (SIZE(0..64))read-writemandatory
standbyExtEthernetInterfaceIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.4IpAddressread-writemandatory
standbyExtEthernetInterfaceDataRate
OBJECT-TYPE
Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G or Auto. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.5INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1Gigabit(6)}read-writemandatory
standbyExtEthernetInterfaceDuplexSetting
OBJECT-TYPE
Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.6INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)}read-writemandatory
standbyExtEthernetInterfaceLAA
OBJECT-TYPE
Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup MM, it is not recommended.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.7OCTET STRING (SIZE(17))read-writemandatory
standbyExtEthernetInterfaceDhcpEnabled
OBJECT-TYPE
Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.8INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)}read-writemandatory
standbyExtEthernetInterfaceGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.9IpAddressread-writemandatory
standbyExtEthernetInterfaceBIA
OBJECT-TYPE
Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.10OCTET STRING (SIZE(17))read-onlymandatory
standbyExtEthernetInterfaceMTU
OBJECT-TYPE
Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.13INTEGERread-writemandatory
standbyExtEthernetInterfaceSubnetMask
OBJECT-TYPE
Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.14IpAddressread-writemandatory
advancedFailover
OBJECT-TYPE
User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, do not swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.15INTEGER {off(0), ipnoswap(1), ipswap(2)}read-writemandatory
standbyDhcpEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16
standbyDhcpHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1OCTET STRING (SIZE(0..64))read-onlymandatory
standbyDhcpIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2IpAddressread-onlymandatory
standbyDhcpGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3IpAddressread-onlymandatory
standbyDhcpSubnetMask
OBJECT-TYPE
Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4IpAddressread-onlymandatory
standbyDhcpDomainName
OBJECT-TYPE
Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5OCTET STRING (SIZE(0..64))read-onlymandatory
standbyDhcpDHCPServer
OBJECT-TYPE
Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6IpAddressread-onlymandatory
standbyDhcpPrimaryDNSServer
OBJECT-TYPE
Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7IpAddressread-onlymandatory
standbyDhcpSecondaryDNSServer
OBJECT-TYPE
Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8IpAddressread-onlymandatory
standbyDhcpTertiaryDNSServer
OBJECT-TYPE
Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9IpAddressread-onlymandatory
extEthernetInterfaceIPv6
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4
extEthernetInterfaceIPv6Type
OBJECT-TYPE
The type of interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.1OCTET STRING (SIZE(0..16))read-onlymandatory
extEthernetInterfaceIPv6Enabled
OBJECT-TYPE
The current IPv6 enabled or disabled state of this MM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.2INTEGER {enabled(1)}read-writemandatory
extEthernetInterfaceIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5
extEthernetInterfaceIPv6LocalAddress
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1
extEthernetInterfaceIPv6LinkLocalAddress
OBJECT-TYPE
The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1InetAddressIPv6read-onlymandatory
extEthernetInterfaceIPv6StaticIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2
extEthernetInterfaceIPv6StaticIPConfigEnabled
OBJECT-TYPE
The IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceIPv6StaticIPAddress
OBJECT-TYPE
The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2InetAddressIPv6read-writemandatory
extEthernetInterfaceIPv6StaticIPAddressPrefixLen
OBJECT-TYPE
The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3INTEGER (1..128)read-writemandatory
extEthernetInterfaceIPv6StaticIPDefaultRoute
OBJECT-TYPE
The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4InetAddressIPv6read-writemandatory
extEthernetInterfaceIPv6LinkFloatingAddress
OBJECT-TYPE
The IPv6 floating IP address for the external ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.5InetAddressIPv6read-writemandatory
extEthernetInterfaceIPv6AutoIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3
extEthernetInterfaceIPv6AutoIPConfigEnabled
OBJECT-TYPE
The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceDHCPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2
extEthernetInterfaceDHCPv6Enabled
OBJECT-TYPE
The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceDHCPv6IPAddress
OBJECT-TYPE
The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6DomainName
OBJECT-TYPE
The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4OCTET STRING (SIZE(0..64))read-onlymandatory
extEthernetInterfaceDHCPv6PrimaryDNSServer
OBJECT-TYPE
The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6SecondaryDNSServer
OBJECT-TYPE
The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6TertiaryDNSServer
OBJECT-TYPE
The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6Server
OBJECT-TYPE
The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8InetAddressIPv6read-onlymandatory
extEthernetInterfaceIPv6StatelessAutoConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3
extEthernetInterfaceIPv6StatelessAutoConfigEnabled
OBJECT-TYPE
The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceStatelessAutoConfigAddressesTable
OBJECT-TYPE
Table of stateless Auto-Config addresses entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2not-accessiblemandatory
extEthernetInterfaceStatelessAutoConfigAddressesEntry
OBJECT-TYPE
Stateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1not-accessiblemandatory
extEthernetInterfaceStatelessAutoConfigAddressesIndex
OBJECT-TYPE
Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1INTEGERread-onlymandatory
extEthernetInterfaceStatelessAutoConfigAddresses
OBJECT-TYPE
The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2InetAddressIPv6read-onlymandatory
extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen
OBJECT-TYPE
The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3INTEGER (1..128)read-onlymandatory
standbyExtEthernetInterfaceIPv6
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5
standbyEthernetInterfaceIPv6LocalAddress
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1
standbyEthernetInterfaceIPv6LinkLocalAddress
OBJECT-TYPE
The IPv6 link local IP address for the standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2
standbyEthernetInterfaceIPv6StaticIPConfigEnabled
OBJECT-TYPE
The IPv6 static IP address state for the MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1INTEGER {disabled(0), enabled(1)}read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPAddress
OBJECT-TYPE
The IPv6 static IP address for the standby MM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2InetAddressIPv6read-writemandatory
standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen
OBJECT-TYPE
The IPv6 static IP address prefix length for the standyby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3INTEGER (1..128)read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPDefaultRoute
OBJECT-TYPE
The IPv6 static IP address default route for the standby MM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceDHCPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3
standbyEthernetInterfaceDHCPv6Enabled
OBJECT-TYPE
The DHCPv6 enabled or disabled state for the standby MM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1INTEGER {disabled(0), enabled(1)}read-onlymandatory
standbyEthernetInterfaceDHCPv6IPAddress
OBJECT-TYPE
The IPv6 address for the standby MM assigned by DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceDHCPv6DomainName
OBJECT-TYPE
The 64 byte Domain Name for the standby MM assigned by the DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4OCTET STRING (SIZE(0..64))read-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesTable
OBJECT-TYPE
Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4not-accessiblemandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesEntry
OBJECT-TYPE
Stateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1not-accessiblemandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesIndex
OBJECT-TYPE
Index for stateless Auto-Config addresses.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1INTEGERread-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddresses
OBJECT-TYPE
The stateless Auto-Configuration IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen
OBJECT-TYPE
The stateless Auto-Configration address prefix length.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3INTEGER (1..128)read-onlymandatory
ddnsStatus
OBJECT-TYPE
Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration.
1.3.6.1.4.1.2.3.51.2.4.9.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
hostName
OBJECT-TYPE
Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName
1.3.6.1.4.1.2.3.51.2.4.9.1.11OCTET STRING (SIZE(0..64))read-writemandatory
standbyHostName
OBJECT-TYPE
Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.12OCTET STRING (SIZE(0..64))read-writemandatory
domainName
OBJECT-TYPE
The user assigned DNS domain name.
1.3.6.1.4.1.2.3.51.2.4.9.1.13OCTET STRINGread-writemandatory
standbyDomainName
OBJECT-TYPE
The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.14OCTET STRINGread-writemandatory
activateNetworkUpdates
OBJECT-TYPE
When read, the return value indicates if there are any pending network updates ready to be applied. Writing any value will apply any pending network updates immediately.
1.3.6.1.4.1.2.3.51.2.4.9.1.16INTEGER {noPendingUpdates(0), pendingUpdates(1)}read-writemandatory
vlanConfigure
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.20
vlanGlobalState
OBJECT-TYPE
This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the vlanCMMTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.1INTEGER {disable(0), enable(1)}read-writemandatory
vlanCommitTimeout
OBJECT-TYPE
This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.2INTEGER (1..255)read-writemandatory
vlanCommitState
OBJECT-TYPE
This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.3INTEGER {noChangesPending(1), commitNeeded(2), executeCommit(3)}read-writemandatory
vlanCMMTable
OBJECT-TYPE
This table contains the VLAN configuration objects. The default entry has an vlanCMMIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanCMMEntryStatus, at vlanCMMIndex=2 to the value of createRequest(2) and also setting the object, vlanCMMVlanId, at vlanCMMIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20not-accessiblemandatory
vlanCMMEntry
OBJECT-TYPE
VLAN entries.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1not-accessiblemandatory
vlanCMMIndex
OBJECT-TYPE
Index for VLAN entry. If vlanCMMIndex is equal to 1, it is the Default VLAN entry and cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1INTEGER (1..2)read-onlymandatory
vlanCMMVlanId
OBJECT-TYPE
Valid VLAN ID. Allowed values are 5..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanCMMIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanCMMState set to enable(1) or restart(2) for this change to take effect.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2INTEGER (1..4094)read-writemandatory
vlanCMMName
OBJECT-TYPE
This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3OCTET STRING (SIZE(0..31))read-writemandatory
vlanCMMEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanCMMEntryStatus = createRequest 2. Set vlanCMMVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanCMMEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4EntryStatusread-writemandatory
vlanCMMState
OBJECT-TYPE
This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5INTEGER {disable(0), enable(1), restart(2)}read-writemandatory
vlanCMMSOLAccess
OBJECT-TYPE
This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6INTEGER {disable(0), enable(1)}read-writemandatory
vlanCMMTagging
OBJECT-TYPE
This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanCMMIndex value of 1. By default, the entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8INTEGER {disable(0), enable(1)}read-writemandatory
vlanCMMIPv4Address
OBJECT-TYPE
This object sets the IPv4 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31IpAddressread-writemandatory
vlanCMMIPv4Gateway
OBJECT-TYPE
This object sets the IPv4 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32IpAddressread-writemandatory
vlanCMMIPv4Mask
OBJECT-TYPE
This object sets the IPv4 subnet mask for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33IpAddressread-writemandatory
vlanCMMIPv4SubnetRoute1
OBJECT-TYPE
This object sets the IPv4 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51IpAddressread-writemandatory
vlanCMMIPv4SubnetRouteMask1
OBJECT-TYPE
This object sets the IPv4 subnet route mask 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52IpAddressread-writemandatory
vlanCMMIPv4SubnetRoute2
OBJECT-TYPE
This object sets the IPv4 address of the subnet route 2 for VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53IpAddressread-writemandatory
vlanCMMIPv4SubnetRouteMask2
OBJECT-TYPE
This object sets the IPv4 subnet route mask 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54IpAddressread-writemandatory
vlanCMMIPv4SubnetRoute3
OBJECT-TYPE
This object sets the IPv4 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55IpAddressread-writemandatory
vlanCMMIPv4SubnetRouteMask3
OBJECT-TYPE
This object sets the IPv4 subnet route mask 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56IpAddressread-writemandatory
vlanCMMIPv6Address
OBJECT-TYPE
This object sets the IPv6 address for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.71InetAddressIPv6read-writemandatory
vlanCMMIPv6AddressPrefixLen
OBJECT-TYPE
This object sets the IPv6 address prefix length for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.72INTEGER (0..128)read-writemandatory
vlanCMMIPv6Gateway
OBJECT-TYPE
This object sets the IPv6 address for the IP gateway for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.73InetAddressIPv6read-writemandatory
vlanCMMIPv6SubnetRoute1
OBJECT-TYPE
This object sets the IPv6 address of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.91InetAddressIPv6read-writemandatory
vlanCMMIPv6SubnetRoutePrefixLen1
OBJECT-TYPE
This object sets the IPv6 address prefix length of the subnet route 1 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.92INTEGER (0..128)read-writemandatory
vlanCMMIPv6SubnetRoute2
OBJECT-TYPE
This object sets the IPv6 address of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.93InetAddressIPv6read-writemandatory
vlanCMMIPv6SubnetRoutePrefixLen2
OBJECT-TYPE
This object sets the IPv6 address prefix length of the subnet route 2 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.94INTEGER (0..128)read-writemandatory
vlanCMMIPv6SubnetRoute3
OBJECT-TYPE
This object sets the IPv6 address of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.95InetAddressIPv6read-writemandatory
vlanCMMIPv6SubnetRoutePrefixLen3
OBJECT-TYPE
This object sets the IPv6 address prefix length of the subnet route 3 for this VLAN entry. The entry with the vlanCMMIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanCMMState, must be set to enable(1) if the vlanCMMState is currently disable(0), or set to restart(2) if the vlanCMMState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.96INTEGER (0..128)read-writemandatory
vlanCMMTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, vlanCMMTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.21INTEGERread-onlymandatory
tcpProtocols
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3
snmpAgentConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1
snmpSystemContact
OBJECT-TYPE
A NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.1OCTET STRING (SIZE(0..48))read-writemandatory
snmpSystemLocation
OBJECT-TYPE
A NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.2OCTET STRING (SIZE(0..48))read-writemandatory
snmpSystemAgentTrapsDisable
OBJECT-TYPE
Disable or enable SNMP traps.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.3INTEGER {trapsEnabled(0), trapsDisabled(1)}read-writemandatory
snmpAgentCommunityConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4
snmpCommunityTable
OBJECT-TYPE
Table of SNMP Community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1not-accessiblemandatory
snmpCommunityEntry
OBJECT-TYPE
SNMP community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1not-accessiblemandatory
snmpCommunityEntryIndex
OBJECT-TYPE
Index for SNMP Agent Community entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1INTEGER (0..255)read-onlymandatory
snmpCommunityEntryCommunityName
OBJECT-TYPE
SNMP Community entry name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2OCTET STRING (SIZE(0..15))read-writemandatory
snmpCommunityEntryCommunityIpAddress1
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress2
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress3
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityViewType
OBJECT-TYPE
Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6INTEGER {read-Traps(1), write-Read-Traps(2), traps-Only(3)}read-writemandatory
snmpv1SystemAgentEnable
OBJECT-TYPE
Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
snmpv3SystemAgentEnable
OBJECT-TYPE
Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
snmpAgentUserProfileConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9
snmpUserProfileTable
OBJECT-TYPE
Table of SNMPv3 User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1not-accessiblemandatory
snmpUserProfileEntry
OBJECT-TYPE
SNMP User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1not-accessiblemandatory
snmpUserProfileEntryIndex
OBJECT-TYPE
Index for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1INTEGER (0..255)read-onlymandatory
snmpUserProfileEntryContextName
OBJECT-TYPE
SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3OCTET STRING (SIZE(0..31))read-writemandatory
snmpUserProfileEntryAuthProt
OBJECT-TYPE
SNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4INTEGER {md5(2), sha(3)}read-writemandatory
snmpUserProfileEntryPrivProt
OBJECT-TYPE
SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6INTEGER {none(1), des(2), aes(4)}read-writemandatory
snmpUserProfileEntryPrivPassword
OBJECT-TYPE
SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7OCTET STRING (SIZE(0..31))read-writemandatory
snmpUserProfileEntryViewType
OBJECT-TYPE
SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8INTEGER {read-Traps(1), read-Write-Traps(2), traps-Only(3)}read-writemandatory
snmpUserProfileEntryIpAddress
OBJECT-TYPE
SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9OCTET STRING (SIZE(0..63))read-writemandatory
snmpUserProfileEntryUserId
OBJECT-TYPE
The userid for the SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.10OCTET STRING (SIZE(0..31))read-onlymandatory
dnsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.2
dnsEnabled
OBJECT-TYPE
Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.1INTEGER {dnsDisabled(0), dnsEnabled(1)}read-writemandatory
dnsServerIPAddress1
OBJECT-TYPE
Contains the primary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.2IpAddressread-writemandatory
dnsServerIPAddress2
OBJECT-TYPE
Contains the secondary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.3IpAddressread-writemandatory
dnsServerIPAddress3
OBJECT-TYPE
Contains the tertiary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.4IpAddressread-writemandatory
dnsServerIPv6Address1
OBJECT-TYPE
Contains the primary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.12InetAddressIPv6read-writemandatory
dnsServerIPv6Address2
OBJECT-TYPE
Contains the secondary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.13InetAddressIPv6read-writemandatory
dnsServerIPv6Address3
OBJECT-TYPE
Contains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.14InetAddressIPv6read-writemandatory
dnsPriority
OBJECT-TYPE
Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.20INTEGER {ipv6(1), ipv4(2)}read-writemandatory
smtpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.3
smtpServerNameOrIPAddress
OBJECT-TYPE
A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.3.1OCTET STRING (SIZE(0..64))read-writemandatory
attachmentsToEmailAlerts
OBJECT-TYPE
Indicates if the service information should be attached to an email alert.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.2INTEGER {noAttachments(0), attachServiceInformation(1)}read-writemandatory
smtpEmailDomain
OBJECT-TYPE
A NULL terminated string that contains the SMTP email domain. If this field is empty, the MM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.3OCTET STRING (SIZE(0..64))read-writemandatory
tcpApplicationConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.4
telnetInactivityTimeout
OBJECT-TYPE
Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.1INTEGERread-writemandatory
commandModeInactivityTimeout
OBJECT-TYPE
The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.2INTEGERread-writemandatory
secureCommandModeEnable
OBJECT-TYPE
Set Secure TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.3INTEGERread-writemandatory
commandModeEnable
OBJECT-TYPE
Set TCP Command Mode number of connections. MM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.4INTEGERread-writemandatory
slpAddrType
OBJECT-TYPE
Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.5INTEGER {multicast(0), broadcast(1)}read-writemandatory
slpEnable
OBJECT-TYPE
Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.7INTEGER {disabled(0), enabled(1)}read-writemandatory
telnetEnable
OBJECT-TYPE
Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.9INTEGER {disabled(0), enabled(1)}read-writemandatory
sshEnable
OBJECT-TYPE
Disable/Enable SSH.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.10INTEGER {disabled(0), enabled(1)}read-writemandatory
sslServerEnable
OBJECT-TYPE
Disable/Enable SSL Server.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.15INTEGER {disabled(0), enabled(1)}read-writemandatory
sslClientEnable
OBJECT-TYPE
Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.16INTEGER {disabled(0), enabled(1)}read-writemandatory
ftpEnable
OBJECT-TYPE
Disable/Enable FTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.17INTEGER {disabled(0), enabled(1)}read-writemandatory
sftpEnable
OBJECT-TYPE
Disable/Enable SFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.18INTEGER {disabled(0), enabled(1)}read-writemandatory
tftpEnable
OBJECT-TYPE
Disable/Enable TFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.19INTEGER {disabled(0), enabled(1)}read-writemandatory
ftpTimeout
OBJECT-TYPE
The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.23INTEGERread-writemandatory
mmSshServerConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27
mmSshServerHostKeyTable
OBJECT-TYPE
A table that contains per public/private host key pair information.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1not-accessiblemandatory
mmSshServerHostKeyEntry
OBJECT-TYPE
A list of information about a particular public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1not-accessiblemandatory
mmSshServerHostKeyIndex
OBJECT-TYPE
The index of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1INTEGERread-onlymandatory
mmSshServerHostKeyType
OBJECT-TYPE
The type of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2INTEGER {sshDss(1), sshRsa(2)}read-onlymandatory
mmSshServerHostKeySize
OBJECT-TYPE
The size of the public/private host key pair. NOTE: The MM supports only the bits2048 value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)}read-onlymandatory
mmSshServerHostKeyFingerprint
OBJECT-TYPE
The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4OCTET STRINGread-onlymandatory
mmSshServerHostKeyGenerate
OBJECT-TYPE
Initiate the new Host Keys generation process for the MM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2INTEGER {execute(1)}read-writemandatory
mmSshServerHostKeyGenerateProgress
OBJECT-TYPE
Indicate the progress of the key generation process.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3OCTET STRINGread-onlymandatory
cimEnable
OBJECT-TYPE
Disable/Enable CIM (Common Information Model) interface. NOTE: Change to CIM enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.50INTEGER {disabled(0), enabled(1)}read-writemandatory
tcpPortAssignmentCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.5
tcpPortsRestoreDefault
OBJECT-TYPE
Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 FTP: 21 FTP Data: 20 TFTP: 69 SLP: 427 CIM: 5989 NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.1INTEGER {execute(1)}read-writemandatory
httpPortAssignment
OBJECT-TYPE
HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.2INTEGERread-writemandatory
httpsPortAssignment
OBJECT-TYPE
SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.3INTEGERread-writemandatory
telnetPortAssignment
OBJECT-TYPE
Telnet port number. Default value is 23. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.4INTEGERread-writemandatory
sshPortAssignment
OBJECT-TYPE
SSH port number. Default value is 22.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.5INTEGERread-writemandatory
snmpAgentPortAssignment
OBJECT-TYPE
SNMP Agent port number. Default value is 161. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.6INTEGERread-writemandatory
snmpTrapsPortAssignment
OBJECT-TYPE
SNMP Traps port number. Default value is 162. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.7INTEGERread-writemandatory
commandModePortAssignment
OBJECT-TYPE
TCP Command Mode port number. Default value is 6090. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.8INTEGERread-writemandatory
secureCommandModePortAssignment
OBJECT-TYPE
Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.9INTEGERread-writemandatory
ftpPortAssignment
OBJECT-TYPE
FTP port number. Default value is 21. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.13INTEGERread-writemandatory
ftpDataPortAssignment
OBJECT-TYPE
FTP Data port number. Default value is 20. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.14INTEGERread-writemandatory
tftpPortAssignment
OBJECT-TYPE
TFTP port number. Default value is 69.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.15INTEGERread-writemandatory
slpPortAssignment
OBJECT-TYPE
Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.19INTEGERread-writemandatory
cimPortAssignment
OBJECT-TYPE
CIM (Common Information Model) port number. Default value is 5989. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.50INTEGERread-writemandatory
ldapClientCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.6
ldapServer1NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.1OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer1PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.2INTEGERread-writemandatory
ldapServer2NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.3OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer2PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.4INTEGERread-writemandatory
ldapServer3NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.5OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer3PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.6INTEGERread-writemandatory
ldapRootDN
OBJECT-TYPE
A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.7OCTET STRING (SIZE(0..256))read-writemandatory
ldapGroupFilter
OBJECT-TYPE
This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.9OCTET STRING (SIZE(0..511))read-writemandatory
ldapBindingMethod
OBJECT-TYPE
On initial binds to the LDAP server during user authentication, there are two options: Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.10INTEGER {clientAuthentication(1), userPrincipalName(2)}read-writemandatory
ldapClientAuthenticationDN
OBJECT-TYPE
The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. These parameters are configured here. Note that the password can be left blank.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.11OCTET STRING (SIZE(0..64))read-writemandatory
ldapClientAuthenticationPassword
OBJECT-TYPE
The client authentication password
1.3.6.1.4.1.2.3.51.2.4.9.3.6.12OCTET STRING (SIZE(0..16))read-writemandatory
ldapUIDsearchAttribute
OBJECT-TYPE
When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.13OCTET STRING (SIZE(0..64))read-writemandatory
ldapGroupSearchAttribute
OBJECT-TYPE
When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.14OCTET STRING (SIZE(0..64))read-writemandatory
ldapLoginPermissionAttribute
OBJECT-TYPE
When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.15OCTET STRING (SIZE(0..64))read-writemandatory
ldapUseDNSOrPreConfiguredServers
OBJECT-TYPE
The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.16INTEGER {usePreConfiguredLDAPServers(0), useDNSToFindLDAPServers(1)}read-writemandatory
ldapRBSModelCfg
OBJECT-TYPE
There are two mechanisms to authenticate and authorize users on the MM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and MMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. MM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.20INTEGER {oldPermissionString(0), newRBSModel(1)}read-writemandatory
ldapTargetName
OBJECT-TYPE
When administrator chooses Enhanced Role Based Security authentication model, he can associate one MM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The MM target name can be looked as alias of MM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character)
1.3.6.1.4.1.2.3.51.2.4.9.3.6.21OCTET STRING (SIZE(0..16))read-writemandatory
ldapAuthCfg
OBJECT-TYPE
If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.22INTEGER {authenticationAndAuthorization(0), authenticationOnly(1)}read-writemandatory
ldapForestName
OBJECT-TYPE
LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.23OCTET STRING (SIZE(0..64))read-writemandatory
ldapDomainName
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP Domain Name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.24OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer4NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.25OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer4PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.26INTEGERread-writemandatory
uplinkCheckConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.7
uplinkCheckEnabled
OBJECT-TYPE
Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.1INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)}read-writemandatory
uplinkCheckDelay
OBJECT-TYPE
Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.2INTEGERread-writemandatory
logicalUplinkDestination
OBJECT-TYPE
Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.3IpAddressread-writemandatory
logicalUplinkCheckEnabled
OBJECT-TYPE
Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.4INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)}read-writemandatory
logicalUplinkCheckDelay
OBJECT-TYPE
Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.5INTEGERread-writemandatory
physicalUplinkCheckDelayInSecs
OBJECT-TYPE
Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.6INTEGERread-writemandatory
logicalUplinkCheckDelayInSecs
OBJECT-TYPE
Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.7INTEGERread-writemandatory
logicalUplinkIPv6Destination
OBJECT-TYPE
Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.8InetAddressIPv6read-writemandatory
logicalUplinkFailoverPolicy
OBJECT-TYPE
Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.9INTEGER {either(1), both(2)}read-writemandatory
ntpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.8
ntpEnable
OBJECT-TYPE
Disable/Enable the NTP client. The client will update the MM system clock at the frequency specified.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.1INTEGER {disabled(0), enabled(1)}read-writemandatory
ntpIpAddressHostname
OBJECT-TYPE
NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.2OCTET STRING (SIZE(0..63))read-writemandatory
ntpUpdateFrequency
OBJECT-TYPE
The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the MM clock can only be synchronized with the NTP server manually.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.3INTEGERread-writemandatory
ntpLastUpdate
OBJECT-TYPE
The date and time that the NTP server last updated the system clock.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.4OCTET STRINGread-onlymandatory
ntpUpdateClock
OBJECT-TYPE
Update the MM system clock with the specified NTP server. A valid NTP server must be configured first.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.5INTEGER {execute(1)}read-writemandatory
ntpAuthEntry
OBJECT-TYPE
The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key index> must be an integer between 1 and 65535. <key type> must be M. <key> is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: <key index> <key type> It does not return the actual key.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.6OCTET STRINGread-writemandatory
ntpAuthEnable
OBJECT-TYPE
Enables/Disables NTP v3 authentication
1.3.6.1.4.1.2.3.51.2.4.9.3.8.7INTEGER {disabled(0), enabled(1)}read-writemandatory
syslogConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.9
syslogSevFilterLevel
OBJECT-TYPE
syslogSevFilterLevel error/warning/information .
1.3.6.1.4.1.2.3.51.2.4.9.3.9.1INTEGER {error(0), warning(1), information(2)}read-writemandatory
syslogCollectorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2
syslogCollectorTable
OBJECT-TYPE
Table of Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1not-accessiblemandatory
syslogCollectorEntry
OBJECT-TYPE
Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1not-accessiblemandatory
syslogCollectorIndex
OBJECT-TYPE
Index for Syslog Collector entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1INTEGER (0..255)read-onlymandatory
syslogCollectorHostnameOrIpAddress
OBJECT-TYPE
Syslog Collector IP address or host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2OCTET STRING (SIZE(0..63))read-writemandatory
syslogCollectorPort
OBJECT-TYPE
Syslog Collector port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3INTEGER (1..65535)read-writemandatory
syslogCollectorEnable
OBJECT-TYPE
Syslog Collector enable/disable.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
syslogTestPacket
OBJECT-TYPE
Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.3INTEGER {execute(1)}read-writemandatory
solConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10
solGlobalConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10.1
solEnable
OBJECT-TYPE
Disable/Enable SOL dynamically.
1.3.6.1.4.1.2.3.51.2.4.10.1.1INTEGER {solDisabled(0), solEnabled(1)}read-writemandatory
solAccumulateTimeout
OBJECT-TYPE
This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms.
1.3.6.1.4.1.2.3.51.2.4.10.1.3INTEGERread-writemandatory
solCharSendThreshold
OBJECT-TYPE
This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 251
1.3.6.1.4.1.2.3.51.2.4.10.1.4INTEGERread-writemandatory
solRetry
OBJECT-TYPE
Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired.
1.3.6.1.4.1.2.3.51.2.4.10.1.5INTEGERread-writemandatory
solRetryInterval
OBJECT-TYPE
Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back.
1.3.6.1.4.1.2.3.51.2.4.10.1.6INTEGERread-writemandatory
solExitToCliKeySeq
OBJECT-TYPE
This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (.
1.3.6.1.4.1.2.3.51.2.4.10.1.7OCTET STRING (SIZE(0..16))read-writemandatory
solResetBladeKeySeq
OBJECT-TYPE
This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R.
1.3.6.1.4.1.2.3.51.2.4.10.1.8OCTET STRING (SIZE(0..16))read-writemandatory
solBladeConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10.2
solBladeTable
OBJECT-TYPE
SOL Blade configuration table.
1.3.6.1.4.1.2.3.51.2.4.10.2.1not-accessiblemandatory
solBladeEntry
OBJECT-TYPE
SOL Blade table entry
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1not-accessiblemandatory
solBladeIndex
OBJECT-TYPE
SOL Blade table index.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1INTEGERread-onlymandatory
solBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2OCTET STRINGread-onlymandatory
solBladeEnable
OBJECT-TYPE
Disable or enable a SOL on a blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3INTEGER {solBladeDisabled(0), solBladeEnabled(1)}read-writemandatory
solBladeIpAddr
OBJECT-TYPE
This is deprecated in favor of solBladeIpAddr6. IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4IpAddressread-onlydeprecated
solBladeSessionStatus
OBJECT-TYPE
Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)}read-onlymandatory
solBladeCapability
OBJECT-TYPE
Display whether or not the blade support SOL feature.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6INTEGER {notSupport(0), support(1)}read-onlymandatory
solBladeIpAddr6
OBJECT-TYPE
IPv6 address of the blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.7InetAddressIPv6read-onlymandatory
solBladeRetryInterval
OBJECT-TYPE
Retry interval time in miliseconds.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.8INTEGERread-onlymandatory
solBladeRetryCount
OBJECT-TYPE
Retry count.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.9INTEGERread-onlymandatory
solBladeBytesSent
OBJECT-TYPE
Number of bytes sent.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.10INTEGERread-onlymandatory
solBladeBytesReceived
OBJECT-TYPE
Number of bytes received.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.11INTEGERread-onlymandatory
solBladeDestinationMAC
OBJECT-TYPE
MAC address of the blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.12OCTET STRINGread-onlymandatory
solBladeConsoleUserId
OBJECT-TYPE
Sol console user name.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.13OCTET STRINGread-onlymandatory
solBladeConsoleLoginFrom
OBJECT-TYPE
The location information from where the SOL console is logged in.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.14OCTET STRINGread-onlymandatory
solBladeConsoleLoginStart
OBJECT-TYPE
The time that SOL console starts.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.15OCTET STRINGread-onlymandatory
solBladeConsoleLoginEnd
OBJECT-TYPE
The time that SOL console ends.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.16OCTET STRINGread-onlymandatory
chassisInternalNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.11
cinsSupported
OBJECT-TYPE
Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported.
1.3.6.1.4.1.2.3.51.2.4.11.1INTEGERread-onlymandatory
cinGlobalEnable
OBJECT-TYPE
Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: MM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces.
1.3.6.1.4.1.2.3.51.2.4.11.2INTEGER {cinDisabled(0), cinEnabled(1)}read-writemandatory
cinTable
OBJECT-TYPE
Chassis Internal Network (CIN) configuration table.
1.3.6.1.4.1.2.3.51.2.4.11.3not-accessiblemandatory
cinEntry
OBJECT-TYPE
Chassis Internal Network (CIN) table entry.
1.3.6.1.4.1.2.3.51.2.4.11.3.1not-accessiblemandatory
cinIndex
OBJECT-TYPE
Chassis Internal Network (CIN) table index.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.1INTEGERread-onlymandatory
cinDefExists
OBJECT-TYPE
Indicates if a Chassis Internal Network (CIN) definition exists for this index or not.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.2INTEGER {false(0), true(1)}read-onlymandatory
cinDelete
OBJECT-TYPE
Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.3INTEGER {execute(1)}read-writemandatory
cinEnable
OBJECT-TYPE
Disable or enable a Chassis Internal Network (CIN) definition. Enabled: MM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
cinId
OBJECT-TYPE
This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.5INTEGERread-writemandatory
cinIpAddress
OBJECT-TYPE
Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the MM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of MM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address
1.3.6.1.4.1.2.3.51.2.4.11.3.1.6IpAddressread-writemandatory
cinIpv6Address
OBJECT-TYPE
Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.7InetAddressIPv6read-writemandatory
cinStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.11.4
cinStatusTable
OBJECT-TYPE
Table of Chassis Internal Network (CIN) status entry information.
1.3.6.1.4.1.2.3.51.2.4.11.4.1not-accessiblemandatory
cinStatusEntry
OBJECT-TYPE
Chassis Internal Network (CIN) status table entry.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1not-accessiblemandatory
cinStatusIndex
OBJECT-TYPE
The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1INTEGERread-onlymandatory
cinStatusString
OBJECT-TYPE
Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the MM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2OCTET STRINGread-onlymandatory
restartReset
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.7
restartSPImmediately
OBJECT-TYPE
Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.4INTEGER {execute(1)}read-writemandatory
restartStandbyMM
OBJECT-TYPE
Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.7.5INTEGER {execute(1)}read-writemandatory
switchOverRedundantMM
OBJECT-TYPE
Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM.
1.3.6.1.4.1.2.3.51.2.7.7INTEGER {execute(1)}read-writemandatory
resetSPConfigAndRestart
OBJECT-TYPE
Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.20INTEGER {execute(1)}read-writemandatory
resetSPConfigAndRestartSaveLogs
OBJECT-TYPE
Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.21INTEGER {execute(1)}read-writemandatory
components
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22
processorBlade
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1
bladePolicyControl
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.4
bladePolicyControlTable
OBJECT-TYPE
Table of blade power policy control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1not-accessiblemandatory
bladePolicyControlEntry
OBJECT-TYPE
Power policy control entry
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1not-accessiblemandatory
policyControlIndex
OBJECT-TYPE
Blade power policy control index.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1INTEGERread-onlymandatory
policyControlBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
policyControlBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
policyControlBladePowerState
OBJECT-TYPE
The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
policyControlBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
policyControlBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6OCTET STRINGread-onlymandatory
policyLocalPowerControlEnable
OBJECT-TYPE
Blade local power policy control enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
policyWakeOnLanControlEnable
OBJECT-TYPE
Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bladePolicy
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.4.2
bladePolicyLocalPowerControlEnable
OBJECT-TYPE
Blade local power control enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyWakeOnLanControlEnable
OBJECT-TYPE
Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.4INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bladeMonitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.5
bladeSystemStatusTable
OBJECT-TYPE
Table of blade status information.
1.3.6.1.4.1.2.3.51.2.22.1.5.1not-accessiblemandatory
bladeSystemStatusEntry
OBJECT-TYPE
Blade system status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1not-accessiblemandatory
bladeStatusIndex
OBJECT-TYPE
Blade system status index.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1INTEGERread-onlymandatory
bladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
bladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
bladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6OCTET STRINGread-onlymandatory
bladeRemotePowerEnable
OBJECT-TYPE
Remote power state for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7INTEGER {disabled(0), enabled(1)}read-onlymandatory
bladeConnectionType
OBJECT-TYPE
Connection type of the expansion card number one.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeRemoteWakeOnLanEnable
OBJECT-TYPE
Remote wake on LAN state for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13INTEGER {disabled(0), enabled(1), notApplicable(255)}read-onlymandatory
bladeServerExpansion
OBJECT-TYPE
This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14INTEGER {no(0), yes(1)}read-onlymandatory
bladeWidth
OBJECT-TYPE
The width of the blade including any supplement blade attached to it
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15INTEGERread-onlymandatory
bladeServerExpansion2
OBJECT-TYPE
This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17INTEGER {no(0), yes(1)}read-onlymandatory
bladeConnectionType2
OBJECT-TYPE
Connection type of the expansion card number 2.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType3
OBJECT-TYPE
Connection type of the expansion card number 3.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType4
OBJECT-TYPE
Connection type of the expansion card number 4.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType5
OBJECT-TYPE
Connection type of the expansion card number 5.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeHighSpeedConnectionType
OBJECT-TYPE
Connection type of the high speed expansion card number 1.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6), infinibandPassThrough(7)}read-onlymandatory
bladeIOCompatibility
OBJECT-TYPE
I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51OCTET STRINGread-onlymandatory
bladeInventoryReady
OBJECT-TYPE
When a blade management controller or the MM is reset, the blade inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52INTEGER {notReady(0), ready(1)}read-onlymandatory
bladeHealthSummaryTable
OBJECT-TYPE
Table of blade health summary information. Contains information about the overall blade health status.
1.3.6.1.4.1.2.3.51.2.22.1.5.2not-accessiblemandatory
bladeHealthSummaryEntry
OBJECT-TYPE
Blade health summary entry
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1not-accessiblemandatory
bladeHealthSummaryIndex
OBJECT-TYPE
Blade health summary index.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1INTEGERread-onlymandatory
bladeHealthSummaryBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeHealthSummarySeverity
OBJECT-TYPE
System health summary severity.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3OCTET STRINGread-onlymandatory
bladeHealthSummaryDescription
OBJECT-TYPE
System health summary description.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4OCTET STRINGread-onlymandatory
bladeHealthSummaryDateTime
OBJECT-TYPE
System health summary date time.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5OCTET STRINGread-onlymandatory
bladeHealthSummaryEventID
OBJECT-TYPE
System health summary event ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.6OCTET STRINGread-onlymandatory
bladeTemperaturesTable
OBJECT-TYPE
Table of blade temperatures information.
1.3.6.1.4.1.2.3.51.2.22.1.5.3not-accessiblemandatory
bladeTemperaturesEntry
OBJECT-TYPE
Blade temperatures table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1not-accessiblemandatory
temperatureIndex
OBJECT-TYPE
Blade temperatures table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1INTEGERread-onlymandatory
temperatureBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
temperatureBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3INTEGER {false(0), true(1)}read-onlymandatory
temperatureBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
temperatureBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5OCTET STRINGread-onlymandatory
temperatureCPU1
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6OCTET STRINGread-onlymandatory
temperatureCPU2
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7OCTET STRINGread-onlymandatory
temperatureCPU3
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8OCTET STRINGread-onlymandatory
temperatureCPU4
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9OCTET STRINGread-onlymandatory
temperatureDASD1
OBJECT-TYPE
The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10OCTET STRINGread-onlymandatory
bladeSensorTempCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12OCTET STRINGread-onlymandatory
bladeSensor2Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13OCTET STRINGread-onlymandatory
bladeSensor3Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14OCTET STRINGread-onlymandatory
bladeSensor4Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15OCTET STRINGread-onlymandatory
bladeSensor5Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16OCTET STRINGread-onlymandatory
bladeSensor6Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17OCTET STRINGread-onlymandatory
bladeSensor7Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18OCTET STRINGread-onlymandatory
bladeSensor8Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19OCTET STRINGread-onlymandatory
bladeSensor9Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20OCTET STRINGread-onlymandatory
bladeTemperatureThresholdsTable
OBJECT-TYPE
Table of blade temperature thresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.4not-accessiblemandatory
bladeTemperatureThresholdsEntry
OBJECT-TYPE
Blade temperature thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1not-accessiblemandatory
temperatureThresholdIndex
OBJECT-TYPE
Blade temperature threshold table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1INTEGERread-onlymandatory
temperatureThresholdBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
temperatureThresholdBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3INTEGER {false(0), true(1)}read-onlymandatory
temperatureThresholdBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
temperatureThresholdBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5OCTET STRINGread-onlymandatory
temperatureCPU1HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6OCTET STRINGread-onlymandatory
temperatureCPU1Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7OCTET STRINGread-onlymandatory
temperatureCPU1WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8OCTET STRINGread-onlymandatory
temperatureCPU2HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9OCTET STRINGread-onlymandatory
temperatureCPU2Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10OCTET STRINGread-onlymandatory
temperatureCPU2WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11OCTET STRINGread-onlymandatory
temperatureCPU3HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12OCTET STRINGread-onlymandatory
temperatureCPU3Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13OCTET STRINGread-onlymandatory
temperatureCPU3WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14OCTET STRINGread-onlymandatory
temperatureCPU4HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15OCTET STRINGread-onlymandatory
temperatureCPU4Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16OCTET STRINGread-onlymandatory
temperatureCPU4WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17OCTET STRINGread-onlymandatory
temperatureDASD1HardShutdown
OBJECT-TYPE
The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18OCTET STRINGread-onlymandatory
temperatureDASD1Warning
OBJECT-TYPE
The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19OCTET STRINGread-onlymandatory
temperatureDASD1WarningReset
OBJECT-TYPE
The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20OCTET STRINGread-onlymandatory
bladeTempThresholdSensorCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21INTEGER {false(0), true(1)}read-onlymandatory
temperatureSensor1HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22OCTET STRINGread-onlymandatory
temperatureSensor1Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23OCTET STRINGread-onlymandatory
temperatureSensor1WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24OCTET STRINGread-onlymandatory
temperatureSensor2HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25OCTET STRINGread-onlymandatory
temperatureSensor2Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26OCTET STRINGread-onlymandatory
temperatureSensor2WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27OCTET STRINGread-onlymandatory
temperatureSensor3HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28OCTET STRINGread-onlymandatory
temperatureSensor3Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29OCTET STRINGread-onlymandatory
temperatureSensor3WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30OCTET STRINGread-onlymandatory
temperatureSensor4HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31OCTET STRINGread-onlymandatory
temperatureSensor4Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32OCTET STRINGread-onlymandatory
temperatureSensor4WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33OCTET STRINGread-onlymandatory
temperatureSensor5HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34OCTET STRINGread-onlymandatory
temperatureSensor5Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35OCTET STRINGread-onlymandatory
temperatureSensor5WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36OCTET STRINGread-onlymandatory
temperatureSensor6HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37OCTET STRINGread-onlymandatory
temperatureSensor6Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38OCTET STRINGread-onlymandatory
temperatureSensor6WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39OCTET STRINGread-onlymandatory
temperatureSensor7HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40OCTET STRINGread-onlymandatory
temperatureSensor7Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41OCTET STRINGread-onlymandatory
temperatureSensor7WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42OCTET STRINGread-onlymandatory
temperatureSensor8HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43OCTET STRINGread-onlymandatory
temperatureSensor8Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44OCTET STRINGread-onlymandatory
temperatureSensor8WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45OCTET STRINGread-onlymandatory
temperatureSensor9HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46OCTET STRINGread-onlymandatory
temperatureSensor9Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47OCTET STRINGread-onlymandatory
temperatureSensor9WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48OCTET STRINGread-onlymandatory
bladeVoltagesTable
OBJECT-TYPE
Table of blade voltages information.
1.3.6.1.4.1.2.3.51.2.22.1.5.5not-accessiblemandatory
bladeVoltagesEntry
OBJECT-TYPE
Blade voltages table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1not-accessiblemandatory
voltageIndex
OBJECT-TYPE
Blade voltages table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1INTEGERread-onlymandatory
voltageBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
voltageBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3INTEGER {false(0), true(1)}read-onlymandatory
voltageBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
voltageBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5OCTET STRINGread-onlymandatory
bladePlus5Volt
OBJECT-TYPE
+5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6OCTET STRINGread-onlymandatory
bladePlus3pt3Volt
OBJECT-TYPE
+3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7OCTET STRINGread-onlymandatory
bladePlus12Volt
OBJECT-TYPE
+12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8OCTET STRINGread-onlymandatory
bladePlus2pt5Volt
OBJECT-TYPE
+2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10OCTET STRINGread-onlymandatory
bladePlus1pt5Volt
OBJECT-TYPE
+1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11OCTET STRINGread-onlymandatory
bladePlus1pt25Volt
OBJECT-TYPE
+1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12OCTET STRINGread-onlymandatory
bladeVRM1Volt
OBJECT-TYPE
VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13OCTET STRINGread-onlymandatory
bladeSensorVoltCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15OCTET STRINGread-onlymandatory
bladeSensor2Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16OCTET STRINGread-onlymandatory
bladeSensor3Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17OCTET STRINGread-onlymandatory
bladeSensor4Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18OCTET STRINGread-onlymandatory
bladeSensor5Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19OCTET STRINGread-onlymandatory
bladeSensor6Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20OCTET STRINGread-onlymandatory
bladeSensor7Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21OCTET STRINGread-onlymandatory
bladeSensor8Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22OCTET STRINGread-onlymandatory
bladeSensor9Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23OCTET STRINGread-onlymandatory
bladeSensor10Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24OCTET STRINGread-onlymandatory
bladeSensor11Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25OCTET STRINGread-onlymandatory
bladeSensor12Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26OCTET STRINGread-onlymandatory
bladeSensor13Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27OCTET STRINGread-onlymandatory
bladeSensor14Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28OCTET STRINGread-onlymandatory
bladeSensor15Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29OCTET STRINGread-onlymandatory
bladeSensor16Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30OCTET STRINGread-onlymandatory
bladeSensor17Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31OCTET STRINGread-onlymandatory
bladeSensor18Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32OCTET STRINGread-onlymandatory
bladeSensor19Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33OCTET STRINGread-onlymandatory
bladeSensor20Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34OCTET STRINGread-onlymandatory
bladeSensor21Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35OCTET STRINGread-onlymandatory
bladeSensor22Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36OCTET STRINGread-onlymandatory
bladeSensor23Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37OCTET STRINGread-onlymandatory
bladeSensor24Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38OCTET STRINGread-onlymandatory
bladeSensor25Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39OCTET STRINGread-onlymandatory
bladeSensor26Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40OCTET STRINGread-onlymandatory
bladeSensor27Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41OCTET STRINGread-onlymandatory
bladeSensor28Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42OCTET STRINGread-onlymandatory
bladeSensor29Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43OCTET STRINGread-onlymandatory
bladeSensor30Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44OCTET STRINGread-onlymandatory
bladeVoltageThresholdsTable
OBJECT-TYPE
Table of blade VoltageThresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.6not-accessiblemandatory
bladeVoltageThresholdsEntry
OBJECT-TYPE
Blade voltage thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1not-accessiblemandatory
voltageThresholdIndex
OBJECT-TYPE
Blade voltage thresholds table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1INTEGERread-onlymandatory
voltageThresholdBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
voltageThresholdBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3INTEGER {false(0), true(1)}read-onlymandatory
voltageThresholdBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
voltageThresholdBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5OCTET STRINGread-writemandatory
bladePlus5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6OCTET STRINGread-onlymandatory
bladePlus5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7OCTET STRINGread-onlymandatory
bladePlus3pt3VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8OCTET STRINGread-onlymandatory
bladePlus3pt3VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9OCTET STRINGread-onlymandatory
bladePlus12VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10OCTET STRINGread-onlymandatory
bladePlus12VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11OCTET STRINGread-onlymandatory
bladePlus2pt5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14OCTET STRINGread-onlymandatory
bladePlus2pt5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15OCTET STRINGread-onlymandatory
bladePlus1pt5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16OCTET STRINGread-onlymandatory
bladePlus1pt5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17OCTET STRINGread-onlymandatory
bladePlus1pt25VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18OCTET STRINGread-onlymandatory
bladePlus1pt25VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19OCTET STRINGread-onlymandatory
bladeVoltThresholdSensorCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23OCTET STRINGread-onlymandatory
bladeSensor1VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24OCTET STRINGread-onlymandatory
bladeSensor2VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25OCTET STRINGread-onlymandatory
bladeSensor2VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26OCTET STRINGread-onlymandatory
bladeSensor3VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27OCTET STRINGread-onlymandatory
bladeSensor3VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28OCTET STRINGread-onlymandatory
bladeSensor4VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29OCTET STRINGread-onlymandatory
bladeSensor4VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30OCTET STRINGread-onlymandatory
bladeSensor5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31OCTET STRINGread-onlymandatory
bladeSensor5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32OCTET STRINGread-onlymandatory
bladeSensor6VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33OCTET STRINGread-onlymandatory
bladeSensor6VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34OCTET STRINGread-onlymandatory
bladeSensor7VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35OCTET STRINGread-onlymandatory
bladeSensor7VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36OCTET STRINGread-onlymandatory
bladeSensor8VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37OCTET STRINGread-onlymandatory
bladeSensor8VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38OCTET STRINGread-onlymandatory
bladeSensor9VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39OCTET STRINGread-onlymandatory
bladeSensor9VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40OCTET STRINGread-onlymandatory
bladeSensor10VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41OCTET STRINGread-onlymandatory
bladeSensor10VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42OCTET STRINGread-onlymandatory
bladeSensor11VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43OCTET STRINGread-onlymandatory
bladeSensor11VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44OCTET STRINGread-onlymandatory
bladeSensor12VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45OCTET STRINGread-onlymandatory
bladeSensor12VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46OCTET STRINGread-onlymandatory
bladeSensor13VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47OCTET STRINGread-onlymandatory
bladeSensor13VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48OCTET STRINGread-onlymandatory
bladeSensor14VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49OCTET STRINGread-onlymandatory
bladeSensor14VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50OCTET STRINGread-onlymandatory
bladeSensor15VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51OCTET STRINGread-onlymandatory
bladeSensor15VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52OCTET STRINGread-onlymandatory
bladeSensor16VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53OCTET STRINGread-onlymandatory
bladeSensor16VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54OCTET STRINGread-onlymandatory
bladeSensor17VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55OCTET STRINGread-onlymandatory
bladeSensor17VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56OCTET STRINGread-onlymandatory
bladeSensor18VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57OCTET STRINGread-onlymandatory
bladeSensor18VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58OCTET STRINGread-onlymandatory
bladeSensor19VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59OCTET STRINGread-onlymandatory
bladeSensor19VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60OCTET STRINGread-onlymandatory
bladeSensor20VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61OCTET STRINGread-onlymandatory
bladeSensor20VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62OCTET STRINGread-onlymandatory
bladeSensor21VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63OCTET STRINGread-onlymandatory
bladeSensor21VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64OCTET STRINGread-onlymandatory
bladeSensor22VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65OCTET STRINGread-onlymandatory
bladeSensor22VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66OCTET STRINGread-onlymandatory
bladeSensor23VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67OCTET STRINGread-onlymandatory
bladeSensor23VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68OCTET STRINGread-onlymandatory
bladeSensor24VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69OCTET STRINGread-onlymandatory
bladeSensor24VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70OCTET STRINGread-onlymandatory
bladeSensor25VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71OCTET STRINGread-onlymandatory
bladeSensor25VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72OCTET STRINGread-onlymandatory
bladeSensor26VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73OCTET STRINGread-onlymandatory
bladeSensor26VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74OCTET STRINGread-onlymandatory
bladeSensor27VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75OCTET STRINGread-onlymandatory
bladeSensor27VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76OCTET STRINGread-onlymandatory
bladeSensor28VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77OCTET STRINGread-onlymandatory
bladeSensor28VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78OCTET STRINGread-onlymandatory
bladeSensor29VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79OCTET STRINGread-onlymandatory
bladeSensor29VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80OCTET STRINGread-onlymandatory
bladeSensor30VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81OCTET STRINGread-onlymandatory
bladeSensor30VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82OCTET STRINGread-onlymandatory
bladePowerRestart
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.6
bladePowerRestartTable
OBJECT-TYPE
Table of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1not-accessiblemandatory
bladePowerRestartEntry
OBJECT-TYPE
Blade power restart table entry
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1not-accessiblemandatory
powerRestartIndex
OBJECT-TYPE
Blade power restart table index.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1INTEGERread-onlymandatory
powerRestartBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
powerRestartBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
powerRestartBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) is returned.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
powerRestartBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The MM is currently in the process of discovering this blade. Communications Error: The MM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
powerRestartBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6OCTET STRINGread-onlymandatory
powerOnOffBlade
OBJECT-TYPE
Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s)
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7INTEGER {off(0), on(1), softoff(2)}read-writemandatory
restartBlade
OBJECT-TYPE
Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8INTEGER {execute(1)}read-writemandatory
restartBladeSMP
OBJECT-TYPE
Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9INTEGER {execute(1)}read-writemandatory
restartBladeNMI
OBJECT-TYPE
Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10INTEGER {execute(1)}read-writemandatory
restartBladeClearNVRAM
OBJECT-TYPE
Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11INTEGER {execute(1)}read-writemandatory
restartBladeInvokeDiags
OBJECT-TYPE
Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12INTEGER {execute(1)}read-writemandatory
restartBladeInvokeDiagsFromDefaultBootList
OBJECT-TYPE
Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13INTEGER {execute(1)}read-writemandatory
restartBladeToSMSBootMenu
OBJECT-TYPE
Restart a blade to SMS boot menu. This option is not supported on all blades, and at the time of this MIB definition was only supported on POWER blades. This object is deprecated and please use the bladePowerEnableSMSBootMenu object. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14INTEGER {execute(1)}read-writedeprecated
bladePowerEnableSMSBootMenu
OBJECT-TYPE
Enables/disables a blade restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all blades, and at the time of this MIB definition was only supported on POWER blades.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
bladeConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.7
bladeConfigurationTable
OBJECT-TYPE
Table of blade configuration information. Contains boot mode and auto power on/off settings for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.1not-accessiblemandatory
bladeConfigurationEntry
OBJECT-TYPE
Blade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1not-accessiblemandatory
configurationIndex
OBJECT-TYPE
Blade configuration table index.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1INTEGERread-onlymandatory
configurationBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
configurationBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
configurationBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
configurationBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5OCTET STRINGread-writemandatory
configurationBladeActiveBootMode
OBJECT-TYPE
Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7INTEGER {temporary(1), permanent(2), notApplicable(255)}read-onlymandatory
configurationBladePendingBootMode
OBJECT-TYPE
Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8INTEGER {temporary(1), permanent(2), notApplicable(255)}read-writemandatory
configurationBladeAutoPowerOn
OBJECT-TYPE
Blade auto-power on policy. - restore: blade will be powered on which were previously on. - auto: blade will automatically be powered on when power is applied to the chassis. - manual: blade will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.9INTEGER {restore(1), auto(2), manual(3), notApplicable(255)}read-writemandatory
configurationBladePowerOnRestartDelay
OBJECT-TYPE
Restart delay (in seconds) when power is applied to a blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.10INTEGER (0..32767)read-writemandatory
bladePowerManagementPolicy
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.7.2
powerManagementPolicy
OBJECT-TYPE
Power Module Redundancy Intended for a single power source into the chassis where each Power Module is on its own dedicated circuit. Maximum power is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting compute node operation. Multiple Power Module failures can cause the chassis to power off. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Compute Nodes Throttling Allowed Very similar to Power Module Redundancy. This policy allows for a higher power limit; however, capable compute nodes may be allowed to throttle down if one Power Module fails. Basic Power Management Maximum power limit is higher than other policies and is limited only by the nameplate power of all the Power Modules combined. This is the least conservative approach, since it does not provide any protection for power source or Power Module failure. If any single power supply fails, compute node and/or chassis operation may be affected. Power Source Redundancy Intended for dual power sources into the chassis. Maximum power is limited to the capacity of half the number of installed power modules. This is the most conservative approach and is recommended when all power modules are installed. When the chassis is correctly wired with dual power sources, one power source can fail without affecting compute node server operation. Note that some compute nodes may not be allowed to power on if doing so would exceed the policy power limit. Power Source Redundancy with Compute Node Throttling Allowed Very similar to the Power Source Redundancy. This policy allows for a higher power limit, however capable compute nodes may be allowed to throttle down if one power source fails. Please see the powerPolicyTable for more information regarding this setting.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.1INTEGER {power-module-redundancy(0), power-module-redundancy-throttle(1), basic(2), power-source-redundancy(16), power-source-redundancy-throttle(17)}read-writemandatory
acousticMode
OBJECT-TYPE
Acoustic mode setting for thermal conditions. A setting of disabled (0), disables this feature. A setting of acoustic-quiet-level1 (5) is the least restrictive and the least quiet sound level. A setting of acoustic-quiet-level5 (1) is the most restrictive and the most quiet sound level. Some values may not be valid on some chassis. A bad value will be returned in this case.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.3INTEGER {disabled(0), acoustic-quiet-level1(1), acoustic-quiet-level2(2), acoustic-quiet-level3(3), acoustic-quiet-level4(4), acoustic-quiet-level5(5)}read-writemandatory
bladeBootCountPowerOnTime
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.10
bladeBootCountPowerOnTimeTable
OBJECT-TYPE
Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1not-accessiblemandatory
bladeBootCountPowerOnTimeEntry
OBJECT-TYPE
The number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1not-accessiblemandatory
bootCountPowerOnTimeBladeIndex
OBJECT-TYPE
Blade boot count/Power On Time table index.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1INTEGERread-onlymandatory
bootCountPowerOnTimeBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bootCountPowerOnTimeBoots
OBJECT-TYPE
Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3INTEGERread-writemandatory
bootCountPowerOnTimeSecs
OBJECT-TYPE
Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4INTEGERread-writemandatory
bladeVlanId
OBJECT-TYPE
This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.11INTEGERread-writemandatory
bladeNetworkConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.12
bladeIPv4ConfigTable
OBJECT-TYPE
Table of all blades' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.1.12.5not-accessiblemandatory
bladeIPv4ConfigEntry
OBJECT-TYPE
Blade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1not-accessiblemandatory
bladeIPv4ConfigIndex
OBJECT-TYPE
The blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.1INTEGERread-onlymandatory
bladeIPv4ConfigPortIndex
OBJECT-TYPE
The physical port number of the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.2INTEGERread-onlymandatory
bladeIPv4ConfigPortLabel
OBJECT-TYPE
Show string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.3OCTET STRINGread-onlymandatory
bladeIPv4ConfigPhysicalLinkStatus
OBJECT-TYPE
Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.4INTEGER {down(0), up(1), notApplicable(255)}read-onlymandatory
bladeIPv4ConfigPhysicalLinkState
OBJECT-TYPE
Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, bladeIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.5INTEGER {down(0), up(1), loopback(2), notApplicable(255)}read-writemandatory
bladeIPv4ConfigIPAddr
OBJECT-TYPE
Show/modify current IP address of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.6IpAddressread-writemandatory
bladeIPv4ConfigSubnetMask
OBJECT-TYPE
Show or modifie current subnet mask of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.7IpAddressread-writemandatory
bladeIPv4ConfigGatewayAddr
OBJECT-TYPE
Show or modify current IP gateway of the blade network interface. Note that only if the bladeIPv4ConfigPhysicalLinkStatus is 'up(1)' and the bladeIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to blade System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.8IpAddressread-writemandatory
bladeIPv4ConfigVlanId
OBJECT-TYPE
This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.9INTEGERread-writemandatory
bladeIPv4ConfigDHCPEnable
OBJECT-TYPE
IP config method on the blade network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.10INTEGER {useStatic(0), useDhcp(1), tryDhcpThenTryStatic(2), notApplicable(255)}read-writemandatory
bladeIPv4ConfigMACAddr
OBJECT-TYPE
Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'.
1.3.6.1.4.1.2.3.51.2.22.1.12.5.1.11OCTET STRINGread-onlymandatory
bladeIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.12.10
bladeIPv6ConfigTable
OBJECT-TYPE
A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1not-accessiblemandatory
bladeIPv6ConfigEntry
OBJECT-TYPE
IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1not-accessiblemandatory
bladeIPv6ConfigIndex
OBJECT-TYPE
The blade's slot number
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1INTEGERread-onlymandatory
bladeIPv6ConfigPortIndex
OBJECT-TYPE
The physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2INTEGERread-onlymandatory
bladeIPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables IPv6 support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6ConfigStatic
OBJECT-TYPE
Enables/Disables IPv6 static configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4INTEGER {disable(0), enable(1)}read-writemandatory
bladeDHCPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables DHCPv6 address configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6ConfigStatelessEnabled
OBJECT-TYPE
Enables/Disables IPv6 stateless auto-configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6AddressTable
OBJECT-TYPE
A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2not-accessiblemandatory
bladeIPv6AddressEntry
OBJECT-TYPE
The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1not-accessiblemandatory
bladeIPv6AddressIndex
OBJECT-TYPE
The blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1INTEGERread-onlymandatory
bladeIPv6AddressPortIndex
OBJECT-TYPE
The blade's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2INTEGERread-onlymandatory
bladeIPv6AddressEntryIndex
OBJECT-TYPE
The blade's address entry index.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3INTEGERread-onlymandatory
bladeIPv6AddressType
OBJECT-TYPE
The address type.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)}read-onlymandatory
bladeIPv6Address
OBJECT-TYPE
The assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5InetAddressIPv6read-writemandatory
bladeIPv6AddressPrefixLen
OBJECT-TYPE
The prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6INTEGER (1..128)read-writemandatory
bladeIPv6AddressDefaultRoute
OBJECT-TYPE
The default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7InetAddressIPv6read-writemandatory
bladeBayDataTable
OBJECT-TYPE
Table of blade bay data (BBD) information.
1.3.6.1.4.1.2.3.51.2.22.1.13not-accessiblemandatory
bladeBayDataEntry
OBJECT-TYPE
Blade bay data (BBD) table entry.
1.3.6.1.4.1.2.3.51.2.22.1.13.1not-accessiblemandatory
bayDataIndex
OBJECT-TYPE
Blade bay data (BBD) table index.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.1INTEGERread-onlymandatory
bayDataBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bayDataBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.3INTEGER {false(0), true(1)}read-onlymandatory
bayDataBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
bayDataBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.5OCTET STRINGread-onlymandatory
bayData
OBJECT-TYPE
A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.6OCTET STRINGread-writemandatory
bayDataBladeStatus
OBJECT-TYPE
This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.7INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)}read-onlymandatory
bladeSPEthOverUSBInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.14
spEthOverUSBInterfaceTable
OBJECT-TYPE
Table of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.1.14.1not-accessiblemandatory
spEthOverUSBInterfaceEntry
OBJECT-TYPE
Blade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1not-accessiblemandatory
spEthOverUSBInterfaceIndex
OBJECT-TYPE
Service Processor's Ethernet over USB interface table index.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1INTEGERread-onlymandatory
spEthOverUSBInterfaceBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2OCTET STRINGread-onlymandatory
spEthOverUSBInterfaceBladeExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
spEthOverUSBInterfaceBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6OCTET STRINGread-onlymandatory
spEthOverUSBInterfaceEnable
OBJECT-TYPE
This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bootDeviceInfoTable
OBJECT-TYPE
Table of blade boot device information. Contains info for the boot devices for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.15not-accessiblemandatory
bootDeviceInfoEntry
OBJECT-TYPE
Boot device entry
1.3.6.1.4.1.2.3.51.2.22.1.15.1not-accessiblemandatory
bootInfoTopologyIndex
OBJECT-TYPE
The unique identifier for a node containing boot devices in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade
1.3.6.1.4.1.2.3.51.2.22.1.15.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
bootDeviceIndex
OBJECT-TYPE
An index for the boot device for the given topology id.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.2INTEGER (0..255)read-onlymandatory
bootDeviceId
OBJECT-TYPE
The device Id of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.3OCTET STRINGread-onlymandatory
bootDeviceActive
OBJECT-TYPE
Specifies whether the boot device is active.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.4INTEGER {no(0), yes(1)}read-onlymandatory
bootDevicePresence
OBJECT-TYPE
Specifies whether the boot device is present.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.5INTEGER {no(0), yes(1)}read-onlymandatory
bootDeviceLabel
OBJECT-TYPE
The device label of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.6OCTET STRINGread-onlymandatory
bootDeviceUserLabel
OBJECT-TYPE
The user label of the boot device.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.7OCTET STRINGread-onlymandatory
bootDeviceOrder
OBJECT-TYPE
The sequence number in boot order of the boot device. 0 specifies this device is not in the boot sequence.
1.3.6.1.4.1.2.3.51.2.22.1.15.1.8INTEGER (0..255)read-onlymandatory
bootSequenceInfoTable
OBJECT-TYPE
Table of blade boot sequence information. Contains the boot sequence information for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.16not-accessiblemandatory
bootSequenceInfoEntry
OBJECT-TYPE
Boot sequence entry
1.3.6.1.4.1.2.3.51.2.22.1.16.1not-accessiblemandatory
bootSequenceInfoTopologyIndex
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the relevant numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade
1.3.6.1.4.1.2.3.51.2.22.1.16.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
bootSequenceInfoMaxBootDevices
OBJECT-TYPE
The maximum number of boot devices.
1.3.6.1.4.1.2.3.51.2.22.1.16.1.2INTEGER (0..255)read-onlymandatory
bootSequenceInfoBootSequence
OBJECT-TYPE
A blank delimited string of device ids in the order of the boot sequence. For example, 00000001 00000002 00000005. Note that the boot sequence list can change from a given order and can grow from a given order, but cannot be reduced in length. For example, if the sequence starts as 00000001 00000011, it could change to 00000001 00000014 or grow to 00000001 00000014 00000002. In the example above, if the 00000002 selection was no longer desired, the list should be changed to 00000001 00000014 00000014, essentially repeating the last device ID. Device ids must be listed in bootDeviceInfoTable.
1.3.6.1.4.1.2.3.51.2.22.1.16.1.3OCTET STRINGread-writemandatory
switchModule
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3
switchModuleControl
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.1
smControlTable
OBJECT-TYPE
Switch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.1not-accessiblemandatory
smControlEntry
OBJECT-TYPE
Switch module control table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1not-accessiblemandatory
smControlIndex
OBJECT-TYPE
Switch module control table index.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1INTEGERread-onlymandatory
switchModuleControlId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smPostResultsAvailable
OBJECT-TYPE
Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smPostResultsValue
OBJECT-TYPE
The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4OCTET STRINGread-onlymandatory
switchModuleMemDiagEnableDisable
OBJECT-TYPE
Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5INTEGER {enabled(0), disabled(1)}read-writedeprecated
smCfgCtrlEnableDisable
OBJECT-TYPE
Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
smExtEthPortsEnableDisable
OBJECT-TYPE
Switch module non-management ethernet ports enabled or disabled. This MIB object can not be set, if MM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
smCfgCtrlOnResetEnableDisable
OBJECT-TYPE
Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9INTEGER {enabled(0), disabled(1)}read-writemandatory
smHealthState
OBJECT-TYPE
The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
smPMState
OBJECT-TYPE
The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the MM. pending - Protected Mode has been activated on the MM but not yet on the switch module. active - Protected Mode is active on both the switch module and the MM. attention - Protected Mode is enabled on the switch module but not on the MM.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16INTEGER {disabled(0), pending(1), attention(2), active(3), notApplicable(255)}read-onlymandatory
smPMCtrlEnableDisable
OBJECT-TYPE
MM Protected Mode permission for the switch module. disabled - allow MM to disable Protected Mode Permission for the switch module. enabled - allow MM to grant Protected Mode Permission for the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
smIOCompatibility
OBJECT-TYPE
The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18OCTET STRINGread-onlymandatory
smPingTable
OBJECT-TYPE
Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.1.2not-accessiblemandatory
smPingEntry
OBJECT-TYPE
Represents a single address that can be pinged
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1not-accessiblemandatory
smPingIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1INTEGERread-onlymandatory
smPingAddressEntryIndex
OBJECT-TYPE
The switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2INTEGERread-onlymandatory
smPingAddress
OBJECT-TYPE
The switch module's IPv4 or IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3OCTET STRINGread-onlymandatory
smPingAddressExecute
OBJECT-TYPE
Pings the given IP address. NOTE: The GET operation for this object is meaningless.
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4INTEGER {execute(1)}read-writemandatory
smPowerRestartTable
OBJECT-TYPE
Switch module power restart table.
1.3.6.1.4.1.2.3.51.2.22.3.1.7not-accessiblemandatory
smPowerRestartEntry
OBJECT-TYPE
Switch module power restart table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1not-accessiblemandatory
smPowerRestartIndex
OBJECT-TYPE
Switch module power restart index.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1INTEGERread-onlymandatory
smPowerRestartId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smSwitchExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3INTEGER {false(0), true(1)}read-onlymandatory
smMACAddress
OBJECT-TYPE
Switch module MAC address. For IOMs which are members of a stack, this field is not applicable and should be disregarded.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5OCTET STRINGread-onlymandatory
smIPAddress
OBJECT-TYPE
The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6IpAddressread-onlymandatory
switchModulePowerOnOff
OBJECT-TYPE
I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. This MIB object can not be set, if MM grants the I/O Module the Protected Mode permission and module goes into Protected Mode.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7INTEGER {poweroff(0), poweron(1), shutdownInProgress(2)}read-writemandatory
smReset
OBJECT-TYPE
For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8INTEGER {execute(1)}read-writemandatory
smResetToDefault
OBJECT-TYPE
For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if MM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9INTEGER {execute(1)}read-writemandatory
smRestartAndRunStdDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10INTEGER {execute(1)}read-writemandatory
smRestartAndRunExtDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11INTEGER {execute(1)}read-writemandatory
smRestartAndRunFullDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12INTEGER {execute(1)}read-writemandatory
smPowerOnRestartDelay
OBJECT-TYPE
Restart delay (in seconds) when power is applied to a switch module.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.15INTEGER (0..32767)read-writemandatory
smSwitchWidth
OBJECT-TYPE
Switch module width.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21INTEGERread-onlymandatory
smManufacturingID
OBJECT-TYPE
Switch module hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22OCTET STRINGread-onlymandatory
smStackingModeState
OBJECT-TYPE
The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23INTEGER {standby(0), member(1), master(2), notApplicable(255)}read-onlymandatory
smStackingModeInfo
OBJECT-TYPE
A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24OCTET STRINGread-onlymandatory
smIOCompatibilityTable
OBJECT-TYPE
Switch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.10not-accessiblemandatory
smIOCompatibilityEntry
OBJECT-TYPE
Switch module IO compatibility table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1not-accessiblemandatory
smIOCompatibilityIndex
OBJECT-TYPE
Switch module IO compatibility index.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1INTEGERread-onlymandatory
smIOCompatibilityId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smIOCompatibilityModuleBay
OBJECT-TYPE
The modules (identified by an id string) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module).
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3OCTET STRINGread-onlymandatory
smIOCompatibilityModulePower
OBJECT-TYPE
The power state of the module specified in smIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4OCTET STRINGread-onlymandatory
smIOCompatibilityModuleFabricType
OBJECT-TYPE
The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot).
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5OCTET STRINGread-onlymandatory
smIOCompatibilityStatus
OBJECT-TYPE
The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6OCTET STRINGread-onlymandatory
smIOCompatibilityTargetTopologyPath
OBJECT-TYPE
The unique identifier for a component which communicates with this IO module. This is the same component identified with an id string in the smIOCompatibilityModuleBay column. The installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.7OCTET STRING (SIZE(0..100))read-onlymandatory
switchModuleConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2
switchMgmtNetworkCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1
switchCurrentNwCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1
smCurrentIPInfoTable
OBJECT-TYPE
Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1not-accessiblemandatory
smCurrentIPInfoEntry
OBJECT-TYPE
Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1not-accessiblemandatory
smCurrentIPInfoIndex
OBJECT-TYPE
Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1INTEGERread-onlymandatory
smCurrentIPInfoId
OBJECT-TYPE
The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smCurrentIPInfoExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smCurrentIPInfoPowerState
OBJECT-TYPE
Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4INTEGER {off(0), on(1), shutdownInProgress(2)}read-onlymandatory
smCurrentIPAddr
OBJECT-TYPE
The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6IpAddressread-onlymandatory
smCurrentSubnetMask
OBJECT-TYPE
The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7IpAddressread-onlymandatory
smCurrentGateway
OBJECT-TYPE
The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8IpAddressread-onlymandatory
smCurrentIPConfigMethod
OBJECT-TYPE
The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)}read-onlymandatory
switchNewNwCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2
smNewIPInfoTable
OBJECT-TYPE
Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1not-accessiblemandatory
smNewIPInfoEntry
OBJECT-TYPE
Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1not-accessiblemandatory
smNewIPInfoIndex
OBJECT-TYPE
Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1INTEGERread-onlymandatory
smNewIPInfoId
OBJECT-TYPE
The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNewIPInfoExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNewIPInfoPowerState
OBJECT-TYPE
Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected..
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNewIPAddr
OBJECT-TYPE
The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6IpAddressread-writemandatory
smNewSubnetMask
OBJECT-TYPE
The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7IpAddressread-writemandatory
smNewGateway
OBJECT-TYPE
The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8IpAddressread-writemandatory
smNewIPConfigMethod
OBJECT-TYPE
The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)}read-writemandatory
smNewIPConfigEnableDisable
OBJECT-TYPE
A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the MM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10INTEGER {disable(0), enable(1)}read-writemandatory
switchIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4
smIPv6ConfigTable
OBJECT-TYPE
A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1not-accessiblemandatory
smIPv6ConfigEntry
OBJECT-TYPE
IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1not-accessiblemandatory
smIPv6ConfigIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1INTEGERread-onlymandatory
smIPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables IPv6 support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2INTEGER {enable(1)}read-writemandatory
smIPv6ConfigStatic
OBJECT-TYPE
Enables/Disables IPv6 static configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3INTEGER {disable(0), enable(1)}read-writemandatory
smDHCPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables DHCPv6 address configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4INTEGER {disable(0), enable(1)}read-writemandatory
smIPv6ConfigStatelessEnabled
OBJECT-TYPE
Enables/Disables IPv6 stateless auto-configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
smIPv6AddressTable
OBJECT-TYPE
A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2not-accessiblemandatory
smIPv6AddressEntry
OBJECT-TYPE
The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1not-accessiblemandatory
smIPv6AddressIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1INTEGERread-onlymandatory
smIPv6AddressEntryIndex
OBJECT-TYPE
The switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2INTEGERread-onlymandatory
smIPv6AddressType
OBJECT-TYPE
The address type.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3INTEGER {static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5)}read-onlymandatory
smIPv6Address
OBJECT-TYPE
The assigned IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4InetAddressIPv6read-onlymandatory
smIPv6AddressPrefixLen
OBJECT-TYPE
The prefix length for the given address.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5INTEGERread-onlymandatory
smIPv6AddressDefaultRoute
OBJECT-TYPE
The default route used for the given address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6InetAddressIPv6read-onlymandatory
smIPv6StaticConfigTable
OBJECT-TYPE
Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3not-accessiblemandatory
smIPv6StaticConfigEntry
OBJECT-TYPE
The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1not-accessiblemandatory
smIPv6StaticIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1INTEGERread-onlymandatory
smIPv6StaticAddress
OBJECT-TYPE
The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2InetAddressIPv6read-writemandatory
smIPv6StaticAddressPrefixLen
OBJECT-TYPE
The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3INTEGERread-writemandatory
smIPv6StaticAddressDefaultRoute
OBJECT-TYPE
The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4InetAddressIPv6read-writemandatory
switchPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2
switchModOnePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1
smOnePortCfgTable
OBJECT-TYPE
Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1not-accessiblemandatory
smOnePortCfgEntry
OBJECT-TYPE
Switch Module 1 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1not-accessiblemandatory
smOnePortCfgIndex
OBJECT-TYPE
Switch Module 1 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1INTEGERread-onlymandatory
smOnePortCfgLabel
OBJECT-TYPE
Switch Module 1 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2OCTET STRINGread-onlymandatory
smOnePortCfgType
OBJECT-TYPE
Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smOnePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smOnePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smOnePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mh: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6OCTET STRINGread-writemandatory
smOnePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7OCTET STRINGread-onlymandatory
smOnePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8OCTET STRINGread-onlymandatory
smOnePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smOnePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smOnePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11INTEGERread-onlymandatory
smOnePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12INTEGERread-onlymandatory
smOnePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13OCTET STRINGread-onlymandatory
smOnePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14OCTET STRINGread-onlymandatory
smOnePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smOnePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModTwoPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2
smTwoPortCfgTable
OBJECT-TYPE
Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1not-accessiblemandatory
smTwoPortCfgEntry
OBJECT-TYPE
Switch Module 2 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1not-accessiblemandatory
smTwoPortCfgIndex
OBJECT-TYPE
Switch Module 2 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1INTEGERread-onlymandatory
smTwoPortCfgLabel
OBJECT-TYPE
Switch Module 2 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2OCTET STRINGread-onlymandatory
smTwoPortCfgType
OBJECT-TYPE
Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smTwoPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smTwoPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smTwoPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6OCTET STRINGread-writemandatory
smTwoPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7OCTET STRINGread-onlymandatory
smTwoPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8OCTET STRINGread-onlymandatory
smTwoPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smTwoPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smTwoPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11INTEGERread-onlymandatory
smTwoPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12INTEGERread-onlymandatory
smTwoPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13OCTET STRINGread-onlymandatory
smTwoPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14OCTET STRINGread-onlymandatory
smTwoPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smTwoPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModThreePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3
smThreePortCfgTable
OBJECT-TYPE
Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1not-accessiblemandatory
smThreePortCfgEntry
OBJECT-TYPE
Switch Module 3 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1not-accessiblemandatory
smThreePortCfgIndex
OBJECT-TYPE
Switch Module 3 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1INTEGERread-onlymandatory
smThreePortCfgLabel
OBJECT-TYPE
Switch Module 3 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2OCTET STRINGread-onlymandatory
smThreePortCfgType
OBJECT-TYPE
Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smThreePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smThreePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smThreePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6OCTET STRINGread-writemandatory
smThreePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7OCTET STRINGread-onlymandatory
smThreePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8OCTET STRINGread-onlymandatory
smThreePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smThreePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smThreePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11INTEGERread-onlymandatory
smThreePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12INTEGERread-onlymandatory
smThreePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13OCTET STRINGread-onlymandatory
smThreePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14OCTET STRINGread-onlymandatory
smThreePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smThreePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModFourPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4
smFourPortCfgTable
OBJECT-TYPE
Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1not-accessiblemandatory
smFourPortCfgEntry
OBJECT-TYPE
Switch Module 4 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1not-accessiblemandatory
smFourPortCfgIndex
OBJECT-TYPE
Switch Module 4 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1INTEGERread-onlymandatory
smFourPortCfgLabel
OBJECT-TYPE
Switch Module 4 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2OCTET STRINGread-onlymandatory
smFourPortCfgType
OBJECT-TYPE
Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by MM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smFourPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smFourPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smFourPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6OCTET STRINGread-writemandatory
smFourPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7OCTET STRINGread-onlymandatory
smFourPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8OCTET STRINGread-onlymandatory
smFourPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smFourPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smFourPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11INTEGERread-onlymandatory
smFourPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12INTEGERread-onlymandatory
smFourPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13OCTET STRINGread-onlymandatory
smFourPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14OCTET STRINGread-onlymandatory
smFourPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smFourPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
chassisTopology
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.4
chassisResponseVersion
OBJECT-TYPE
Chassis response version.
1.3.6.1.4.1.2.3.51.2.22.4.1INTEGERread-onlymandatory
chassisFlags
OBJECT-TYPE
Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis.
1.3.6.1.4.1.2.3.51.2.22.4.2INTEGER {rackOrStandAlone(0), serverBlade(1)}read-onlymandatory
chassisNoOfFPsSupported
OBJECT-TYPE
This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.18INTEGERread-onlydeprecated
chassisNoOfBayDevicesSupported
OBJECT-TYPE
Maximum number of bays found in the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.19INTEGERread-onlymandatory
chassisNoOfSMsSupported
OBJECT-TYPE
Number of switch modules (SMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.20INTEGERread-onlymandatory
chassisNoOfMMsSupported
OBJECT-TYPE
Number of management modules (MMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.21INTEGERread-onlymandatory
chassisNoOfPMsSupported
OBJECT-TYPE
Number of power modules (PMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.22INTEGERread-onlymandatory
chassisNoOfRearLEDCardsSupported
OBJECT-TYPE
Number of rear LED cards supported.
1.3.6.1.4.1.2.3.51.2.22.4.23INTEGERread-onlymandatory
chassisNoOfChassisFansSupported
OBJECT-TYPE
Number of chassis fans supported.
1.3.6.1.4.1.2.3.51.2.22.4.24INTEGERread-onlymandatory
chassisBayDevicesInstalled
OBJECT-TYPE
The bay devices that are installed in the chassis. The bay devices are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of bay devices supported. For devices that fill multiple bays, the bit mask will indicate the primary/lowest bay as occupied. If a device is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if devices are installed in bays 1, 5, and 13, and 14 bays are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.22.4.25OCTET STRINGread-onlymandatory
chassisSMsInstalled
OBJECT-TYPE
The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011'.
1.3.6.1.4.1.2.3.51.2.22.4.29OCTET STRINGread-onlymandatory
chassisMMsInstalled
OBJECT-TYPE
The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.30OCTET STRINGread-onlymandatory
chassisPMsInstalled
OBJECT-TYPE
The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.22.4.31OCTET STRINGread-onlymandatory
chassisRearLEDCardInstalled
OBJECT-TYPE
Indicates whether at least one rear LED card is installed.
1.3.6.1.4.1.2.3.51.2.22.4.32INTEGER {no(0), yes(1)}read-onlymandatory
chassisFansInstalled
OBJECT-TYPE
The chassis fans that are installed on the chassis. They are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of supported. If it is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if it is installed in bay 1, and 2 are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.33OCTET STRINGread-onlymandatory
chassisActiveMM
OBJECT-TYPE
The active management module (MM).
1.3.6.1.4.1.2.3.51.2.22.4.34INTEGERread-onlymandatory
chassisFPsInstalled
OBJECT-TYPE
This object is deprecated because the power modules' fan packs are integrated into the power modules and are not removable as on previous power modules. The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.37OCTET STRINGread-onlydeprecated
chassisType
OBJECT-TYPE
The type of the chassis. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.38INTEGER {flex(101)}read-onlymandatory
chassisSubtype
OBJECT-TYPE
The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.39INTEGER {tracewell4(48), tracewell8(49), tracewell7(50), flex(101), unknown(255)}read-onlymandatory
chassisNoOfRearLEDCardsInstalled
OBJECT-TYPE
The rear LED cards that are installed on the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.52OCTET STRINGread-onlymandatory
chassisRoom
OBJECT-TYPE
The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.53OCTET STRING (SIZE(0..24))read-writemandatory
chassisName
OBJECT-TYPE
The name of the chassis. Maximum 15 character long plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.54OCTET STRING (SIZE(0..16))read-writemandatory
chassisRack
OBJECT-TYPE
The name of the room where the chassis is located. Maximum 23 characters for name plus NULL termination.
1.3.6.1.4.1.2.3.51.2.22.4.55OCTET STRING (SIZE(0..24))read-writemandatory
chassisLowestU
OBJECT-TYPE
The lowest U position that is occupied in the rack.
1.3.6.1.4.1.2.3.51.2.22.4.56INTEGERread-writemandatory
chassisUHeight
OBJECT-TYPE
The height of the chassis in 'U' units.
1.3.6.1.4.1.2.3.51.2.22.4.57INTEGERread-onlymandatory
managementModule
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.5
mmStatusTable
OBJECT-TYPE
Table of the management module status.
1.3.6.1.4.1.2.3.51.2.22.5.1not-accessiblemandatory
mmStatusEntry
OBJECT-TYPE
Management module status entry.
1.3.6.1.4.1.2.3.51.2.22.5.1.1not-accessiblemandatory
mmStatusIndex
OBJECT-TYPE
Management module status index.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.1INTEGERread-onlymandatory
mmPresent
OBJECT-TYPE
Management module current status.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.2INTEGER {no(0), yes(1)}read-onlymandatory
mmExtIpAddress
OBJECT-TYPE
Management module external IP address. NOTE: The IPv6 addresses assigned to the MM may be viewed with the extEthernetInterfaceIPv6 objects
1.3.6.1.4.1.2.3.51.2.22.5.1.1.3IpAddressread-onlymandatory
mmPrimary
OBJECT-TYPE
Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.4INTEGER {no(0), yes(1)}read-onlymandatory
mmHealthState
OBJECT-TYPE
The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.5INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
firmwareInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.8
smFirmwareInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.8.1
smFirmwareInfoTable
OBJECT-TYPE
Switch Module firmware image information.
1.3.6.1.4.1.2.3.51.2.22.8.1.1not-accessiblemandatory
smFirmwareInfoEntry
OBJECT-TYPE
Switch Module firmware image information table entry
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1not-accessiblemandatory
smFirmwareInfoIndex
OBJECT-TYPE
Sequence index in the firmware table.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1INTEGERread-onlymandatory
smFirmwareInfoModIndex
OBJECT-TYPE
Switch Module number.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2INTEGERread-onlymandatory
smFirmwareInfoImageIndex
OBJECT-TYPE
Switch Module firmware image index.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3INTEGERread-onlymandatory
smFirmwareInfoImageName
OBJECT-TYPE
Switch Module firmware image name
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4OCTET STRINGread-writemandatory
firmwareUpdate
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.9
firmwareUpdateTarget
OBJECT-TYPE
Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error.
1.3.6.1.4.1.2.3.51.2.22.9.1INTEGER {managementModule(0), switchModule1(11), switchModule2(12), switchModule3(13), switchModule4(14), unknown(255)}read-writemandatory
firmwareUpdateTftpServer
OBJECT-TYPE
If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]).
1.3.6.1.4.1.2.3.51.2.22.9.2OCTET STRING (SIZE(0..63))read-writemandatory
firmwareUpdateFileName
OBJECT-TYPE
File name of the firmware file.
1.3.6.1.4.1.2.3.51.2.22.9.3OCTET STRING (SIZE(0..254))read-writemandatory
firmwareUpdateStart
OBJECT-TYPE
Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the MM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this MM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.9.4INTEGER {execute(1), execute-with-reboot(2), execute-nowait(3), execute-with-reboot-nowait(4)}read-writemandatory
firmwareUpdateStatus
OBJECT-TYPE
Get the status of the last firmware update which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.2.22.9.5OCTET STRINGread-onlymandatory
standbyFirmwareUpdateStatus
OBJECT-TYPE
Get the current status of the firmware update for the standby MM. NOTE: This only applies to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.22.9.6OCTET STRINGread-onlymandatory
firmwareImageNumber
OBJECT-TYPE
If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section.
1.3.6.1.4.1.2.3.51.2.22.9.7INTEGERread-writemandatory
firmwareActiveImage
OBJECT-TYPE
If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.9.8INTEGERread-writemandatory
firmwareUpdateServer
OBJECT-TYPE
Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: cmefs.uxp Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>. Note: When updating certain switches via SFTP, only an RSA fingerprint is supported. Please see your switch documentation for more information.
1.3.6.1.4.1.2.3.51.2.22.9.9OCTET STRING (SIZE(0..254))read-writemandatory
fileManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.11
fileTopology
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.11.1
currentDirectory
OBJECT-TYPE
Specifies the directory name for listing the requested files.
1.3.6.1.4.1.2.3.51.2.22.11.1.1OCTET STRINGread-writemandatory
fileDetailsTable
OBJECT-TYPE
A table of all the files in the specified directory.
1.3.6.1.4.1.2.3.51.2.22.11.1.2not-accessiblemandatory
fileDetailsEntry
OBJECT-TYPE
File details entry.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1not-accessiblemandatory
fileIndex
OBJECT-TYPE
File sequence index.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1INTEGERread-onlymandatory
fileName
OBJECT-TYPE
File name.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2OCTET STRINGread-onlymandatory
fileLastUpdate
OBJECT-TYPE
Date of the latest file update.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3OCTET STRINGread-onlymandatory
fileSize
OBJECT-TYPE
File size in bytes.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4OCTET STRINGread-onlymandatory
fileManagementCmd
OBJECT-TYPE
This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.11.3OCTET STRINGread-writemandatory
fileSystemSpaceAvailable
OBJECT-TYPE
This field displays the available space of the MM file system.
1.3.6.1.4.1.2.3.51.2.22.11.6OCTET STRINGread-onlymandatory
cmeRemoteChassis
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.12
cmeRemoteChassisTable
OBJECT-TYPE
This table is used to provide the discovered MMs based on the new, extended SLP response information.
1.3.6.1.4.1.2.3.51.2.22.12.1not-accessiblemandatory
cmeRemoteChassisEntry
OBJECT-TYPE
Remote chassis entry
1.3.6.1.4.1.2.3.51.2.22.12.1.1not-accessiblemandatory
cmeRemoteChassisIndex
OBJECT-TYPE
Remote chassis discovery sequence index.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.1INTEGERread-onlymandatory
cmeSystemName
OBJECT-TYPE
System name for this discovery management module.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.2OCTET STRINGread-onlymandatory
cmeType
OBJECT-TYPE
Management module service processor type.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.3OCTET STRINGread-onlymandatory
cmeSerial
OBJECT-TYPE
Management module serial number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.4OCTET STRINGread-onlymandatory
cmeFru
OBJECT-TYPE
Management module Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.5OCTET STRINGread-onlymandatory
cmeUuid
OBJECT-TYPE
Management module UUID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.6OCTET STRINGread-onlymandatory
cmeSlot
OBJECT-TYPE
Management module slot.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.7OCTET STRINGread-onlymandatory
cmeMidPid
OBJECT-TYPE
Management module Mid-plane Pid.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.8OCTET STRINGread-onlymandatory
cmeMacAddress
OBJECT-TYPE
Management module MAC address.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.9OCTET STRINGread-onlymandatory
cmeChassisSerial
OBJECT-TYPE
Chassis serial number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.10OCTET STRINGread-onlymandatory
cmeChassisFru
OBJECT-TYPE
Chassis Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.11OCTET STRINGread-onlymandatory
cmeChassisMachineTypeMode
OBJECT-TYPE
Chassis machine type and model number.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.12OCTET STRINGread-onlymandatory
cmeSystemStatus
OBJECT-TYPE
Chassis status.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.13INTEGER {critical(0), non-Critical(2), system-Level(4), unknown(9), noResponse(170), normal(255)}read-onlymandatory
cmeChassisUuid
OBJECT-TYPE
Chassis UUID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.14OCTET STRINGread-onlymandatory
cmeChassisMidPid
OBJECT-TYPE
Chassis mid-plane ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.15OCTET STRINGread-onlymandatory
cmeChassisId
OBJECT-TYPE
Chassis ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.16OCTET STRINGread-onlymandatory
cmeChassisLocation
OBJECT-TYPE
Chassis location information.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.17OCTET STRINGread-onlymandatory
cmeChassisRoomId
OBJECT-TYPE
Chassis room ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.18OCTET STRINGread-onlymandatory
cmeChassisRackId
OBJECT-TYPE
Chassis rack ID.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.19OCTET STRINGread-onlymandatory
cmeChassisUser
OBJECT-TYPE
Chassis user information.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.20OCTET STRINGread-onlymandatory
cmeChassisFruList
OBJECT-TYPE
Chassis FRU list.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.21OCTET STRINGread-onlymandatory
cmeFirmwareVersion
OBJECT-TYPE
Firmware version of the discovery management module.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.22OCTET STRINGread-onlymandatory
cmeChassisType
OBJECT-TYPE
Chassis type.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.23OCTET STRINGread-onlymandatory
cmeIpv4Status
OBJECT-TYPE
A flag to state if IPv4 is enabled
1.3.6.1.4.1.2.3.51.2.22.12.1.1.24INTEGER {disabled(0), enabled(1)}read-onlymandatory
cmeIpv4Addresses
OBJECT-TYPE
The IPv4 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.25OCTET STRINGread-onlymandatory
cmeIpv4AddressesFloat
OBJECT-TYPE
The floating IPv4 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.26OCTET STRINGread-onlymandatory
cmeIpv4Protocols
OBJECT-TYPE
The IPv4 protocols configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.27OCTET STRINGread-onlymandatory
cmeIpv6Status
OBJECT-TYPE
A flag to state if IPv6 is enabled
1.3.6.1.4.1.2.3.51.2.22.12.1.1.28INTEGER {disabled(0), enabled(1)}read-onlymandatory
cmeIpv6Addresses
OBJECT-TYPE
The IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.29OCTET STRINGread-onlymandatory
cmeIpv6AddressesFloat
OBJECT-TYPE
The floating IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.30OCTET STRINGread-onlymandatory
cmeIpv6Protocols
OBJECT-TYPE
The IPv6 protocols configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.12.1.1.31OCTET STRINGread-onlymandatory
chassisDiscovery
OBJECT-TYPE
Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.12.2INTEGER {execute(1)}read-writemandatory
componentPower
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.31
componentPowerTable
OBJECT-TYPE
Table of component remote power control information. Contains power on/off enablement status for each component.
1.3.6.1.4.1.2.3.51.2.22.31.1not-accessiblemandatory
componentPowerEntry
OBJECT-TYPE
Component power/restart table entry
1.3.6.1.4.1.2.3.51.2.22.31.1.1not-accessiblemandatory
componentPowerTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.31.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentPowerName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.31.1.1.2OCTET STRINGread-onlymandatory
componentPowerState
OBJECT-TYPE
Indicates the power state of the component specified. If the state cannot be determined, the unknown(255) is returned.
1.3.6.1.4.1.2.3.51.2.22.31.1.1.3INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
componentPowerAction
OBJECT-TYPE
Control the power state of a specific component. none: No action, value returned for GET. off: Power-off component. on: Power-on component. softoff: Shutdown OS and power-off component. This operation is not supported on all components. restart: Restart a component. restartSysMgmtProcessor: Restart a component's system management processor. restartNMI: Issue a NMI (Non-Maskable Interrupt) restart to the component. This option is not supported on all components. NOTE: Value returned for the GET command is meaningless for this MIB object. The componentPowerState MIB object should be used to check the power state of the component(s)
1.3.6.1.4.1.2.3.51.2.22.31.1.1.4INTEGER {none(0), off(1), on(2), softoff(3), restart(4), restartSysMgmtProcessor(5), restartNMI(6)}read-writemandatory
componentPowerEnableSMSBootMenu
OBJECT-TYPE
Enables/disables a component restart to the SMS boot menu. Setting this object to 'enable(1)' will cause a reboot of the node to the SMS menu. This option is not supported by all components, and at the time of this MIB definition was only supported on POWER blades.
1.3.6.1.4.1.2.3.51.2.22.31.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
componentPowerTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentPowerTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.31.2INTEGERread-onlymandatory
componentPowerDetailsTable
OBJECT-TYPE
Table of component power detail information.
1.3.6.1.4.1.2.3.51.2.22.31.6not-accessiblemandatory
componentPowerDetailsEntry
OBJECT-TYPE
Component power Details table entry
1.3.6.1.4.1.2.3.51.2.22.31.6.1not-accessiblemandatory
componentPowerDetailsTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.31.6.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentPowerDetailsName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.2OCTET STRINGread-onlymandatory
componentPowerDetailsMaxPowerConfig
OBJECT-TYPE
Component Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the component. This function is also known as power capping. Component must be powered on to set this value. If the value of maximum power config is zero, it means the component doesn't support the power capping feature
1.3.6.1.4.1.2.3.51.2.22.31.6.1.3INTEGERread-writemandatory
componentPowerDetailsEffectiveClockRate
OBJECT-TYPE
Component Module Details Table Effective CPU Clock Rate applies to DPM components only. It displays processor's effective clock rate based on sample interval. Note that some components do not effective clock rate. In this case, 'notApplicable' will be displayed. NOTE: The effective clock rate are reported only on a primary slot when a server component spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.4OCTET STRINGread-onlymandatory
componentPowerDetailsMaximumClockRate
OBJECT-TYPE
Component Module Details Table Maximum CPU Clock Rate applies to DPM components only. It displays processor's maximum clock rate based on sample interval. Note that some components do not maximum clock rate. In this case, 'notApplicable' will be displayed. NOTE: The maximum clock rate are reported only on a primary slot when a server components spans multiple slots (e.g. double wide or triple wide). For example if the component is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.5OCTET STRINGread-onlymandatory
componentPowerDetailsPowerSaverMode
OBJECT-TYPE
When enabled, the static low power saver mode allows the component to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsDynamicPowerSaver if its not already disabled.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.6INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
componentPowerDetailsDynamicPowerSaver
OBJECT-TYPE
When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the component to be controlled based on how busy the CPU is. This feature is not available on all component types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable componentPowerDetailsPowerSaverMode if its not already disabled.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.7INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
componentPowerDetailsDynamicPowerFavorPerformanceOverPower
OBJECT-TYPE
When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the component only after Dynamic Power Saver is enabled. This feature is not available on all components types. Please refer to the component documentation for details. If a component does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other component functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.8INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
componentPowerDetailsPowerControl
OBJECT-TYPE
This object is used to get or set the power control setting on a component. If dynamic power mgmt is not supported on a component, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide component. The same can be used if the component is single wide.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.9INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)}read-writemandatory
componentPowerDetailsPcapMin
OBJECT-TYPE
Component Module Details Table power capping Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.10OCTET STRINGread-onlymandatory
componentPowerDetailsPcapGuaranteedMin
OBJECT-TYPE
Component Module Details Table power capping Guaranteed Minimum value in watts. The component must support the advanced power management feature. If the value of Pcap Guaranteed Min is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap GuaranteedMin is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.11OCTET STRINGread-onlymandatory
componentPowerDetailsPcapMax
OBJECT-TYPE
Component Module Details Table power capping Maximum value in watts. The component must support the advanced power management feature. If the value is '<max1> Watts,<max2> Watts', which means, - if componentPowerDetailsDynamicPowerSaver is enabled, it is <max2> - otherwise it is <max1> If the value of Pcap Max is 'notApplicable', it means the component doesn't support the power capping feature. If the value of Pcap Min is 'notAvailable', it means the data could not be obtained.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.12OCTET STRINGread-onlymandatory
componentPowerDetailsStaticCap
OBJECT-TYPE
Component Module Details Table static capabilities list. This is a list of five power management capabilities that the component may or may not support. The list of power management capabilities is as follow: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is not there, '01' indicates that the capability is present on the component. The 5 pairs represent the capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 01 00 00 00' This component has the capability of Power Management and Power Capping, but does not support the last three types.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.13OCTET STRINGread-onlymandatory
componentPowerDetailsRuntimeCap
OBJECT-TYPE
Component Module Details Table run-time capabilities list. If the component supports the capability as indicated in the static capability information, the user has the ability to enable or disable that function and this table reflects that configuration. The power management capabilites for the run-time list is as follows: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is currently not available, '01' indicates that the capability is currently available. The 5 pairs represent the current capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 00 00 00 00' This component has the capability of Power Management only. The current state of the component does not support the remaining 4 capabiites at this time.
1.3.6.1.4.1.2.3.51.2.22.31.6.1.14OCTET STRINGread-onlymandatory
componentPowerDetailsTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentPowerDetailsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.31.7INTEGERread-onlymandatory
componentConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.32
componentBayDataTable
OBJECT-TYPE
Table of component bay User data information. Contains user provided data for each component bay.
1.3.6.1.4.1.2.3.51.2.22.32.1not-accessiblemandatory
componentBayDataEntry
OBJECT-TYPE
Component Bay Data table entry
1.3.6.1.4.1.2.3.51.2.22.32.1.1not-accessiblemandatory
componentBayDataTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentBayDataName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.1.1.2OCTET STRINGread-onlymandatory
componentBayDataStatus
OBJECT-TYPE
This shows Bay Data (BD) Status. 0 means the component fully supports BD. 1 means that the component's BIOS does not support BD. 2 means that there is no component in the bay. 3 means that the component is being discovered. 255 means that the component does not support BBD.
1.3.6.1.4.1.2.3.51.2.22.32.1.1.3INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)}read-onlymandatory
componentBayData
OBJECT-TYPE
A null terminated string that defines the component Bay Data. This data is puched to the components's BSMP and SMBIOS structures, where it can be used by the components's OS. Up to 60 characters can be defined plus a Null terminator.
1.3.6.1.4.1.2.3.51.2.22.32.1.1.4OCTET STRING (SIZE(0..60))read-writemandatory
componentBayDataTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentBayDataTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.2INTEGERread-onlymandatory
componentEthOverUSBInterfaceTable
OBJECT-TYPE
Table of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.32.6not-accessiblemandatory
componentEthOverUSBInterfaceEntry
OBJECT-TYPE
Blade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.32.6.1not-accessiblemandatory
componentEthOverUSBInterfaceTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.6.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentEthOverUSBInterfaceName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.6.1.2OCTET STRINGread-onlymandatory
componentEthOverUSBInterfaceEnable
OBJECT-TYPE
This object allows the user to view the status of, and enable or disable, a component's interface on Ethernet-over-USB. NOTE: If the component either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect.
1.3.6.1.4.1.2.3.51.2.22.32.6.1.3INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
componentEthOverUSBInterfaceTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentEthOverUSBInterfaceTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.7INTEGERread-onlymandatory
componentConfigurationTable
OBJECT-TYPE
Table of component configuration information.
1.3.6.1.4.1.2.3.51.2.22.32.11not-accessiblemandatory
componentConfigurationEntry
OBJECT-TYPE
Component configuration table entry
1.3.6.1.4.1.2.3.51.2.22.32.11.1not-accessiblemandatory
componentConfigurationTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.11.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentConfigurationName
OBJECT-TYPE
The name of the component as a null terminated string. This object is configurable.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.2OCTET STRINGread-writemandatory
componentConfigurationActiveBootMode
OBJECT-TYPE
Indicates the active copy of the firmware from which the component is booting. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.3INTEGER {temporary(1), permanent(2), notApplicable(255)}read-onlymandatory
componentConfigurationPendingBootMode
OBJECT-TYPE
Indicates the copy of the firmware from which the component will boot after the next reboot. NOTE: Some components do not support the automatic boot recovery. It displays 'notApplicable' for such components and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.4INTEGER {temporary(1), permanent(2), notApplicable(255)}read-writemandatory
componentConfigurationAutoPowerOn
OBJECT-TYPE
Component auto-power on policy. - restore: component will be powered on which were previously on. - auto: component will automatically be powered on when power is applied to the chassis. - manual: component will be left off until manually powered on by the user. - notApplicable: is a read-only value, this value cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.5INTEGER {restore(1), auto(2), manual(3), notApplicable(255)}read-writemandatory
componentConfigurationPowerOnRestartDelay
OBJECT-TYPE
Restart delay (in seconds) when power is applied to a component.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.6INTEGER (0..32767)read-writemandatory
componentConfigurationLocalPowerControlEnable
OBJECT-TYPE
Component local power control enablement status.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.7INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
componentConfigurationWakeOnLanControlEnable
OBJECT-TYPE
Component Wake On LAN enablement status. If WOL is not supported by the component, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.32.11.1.8INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
componentConfigurationTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentConfigurationTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.12INTEGERread-onlymandatory
componentNetworkConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.32.16
componentIPv4ConfigTable
OBJECT-TYPE
Table of all components' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.32.16.1not-accessiblemandatory
componentIPv4ConfigEntry
OBJECT-TYPE
Component configuration table entry
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1not-accessiblemandatory
componentIPv4ConfigTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentIPv4ConfigPortIndex
OBJECT-TYPE
The physical port number of the given entry.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.2INTEGERread-onlymandatory
componentIPv4ConfigName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.3OCTET STRINGread-onlymandatory
componentIPv4ConfigPortLabel
OBJECT-TYPE
Show string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.4OCTET STRINGread-onlymandatory
componentIPv4ConfigPhysicalLinkStatus
OBJECT-TYPE
Indicates whether this network interface port is up or down. If this network interface doesn't support up/down, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.5INTEGER {down(0), up(1), notApplicable(255)}read-onlymandatory
componentIPv4ConfigPhysicalLinkState
OBJECT-TYPE
Configuration object for requesting the physical port to be either, down(0), up(1) or loopback(2). To get the current status of a physical port, use the object, componentIPv4ConfigPhysicalLinkStatus. If this network interface doesn't support up/down/loopback, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.6INTEGER {down(0), up(1), loopback(2), notApplicable(255)}read-writemandatory
componentIPv4ConfigIPAddr
OBJECT-TYPE
Show/modify current IP address of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.7IpAddressread-writemandatory
componentIPv4ConfigSubnetMask
OBJECT-TYPE
Show or modifie current subnet mask of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.8IpAddressread-writemandatory
componentIPv4ConfigGatewayAddr
OBJECT-TYPE
Show or modify current IP gateway of the component network interface. Note that only if the componentIPv4ConfigPhysicalLinkStatus is 'up(1)' and the componentIPv4ConfigDHCPEnable is not 'useDhcp(1)', should the IP address be pushed down to component System Management Processor.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.9IpAddressread-writemandatory
componentIPv4ConfigVlanId
OBJECT-TYPE
This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.10INTEGERread-writemandatory
componentIPv4ConfigDHCPEnable
OBJECT-TYPE
IP config method on the component network interface to modify mode to static IP, DHCP and 'try DHCP then try static'. If this network interface doesn't support DHCP, show 'notApplicable(255)'.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.11INTEGER {useStatic(0), useDhcp(1), tryDhcpThenTryStatic(2), notApplicable(255)}read-writemandatory
componentIPv4ConfigMACAddr
OBJECT-TYPE
Show the component network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'.
1.3.6.1.4.1.2.3.51.2.22.32.16.1.1.12OCTET STRINGread-onlymandatory
componentIPv4ConfigTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentIPv4ConfigTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16.2INTEGERread-onlymandatory
componentIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.32.16.11
componentIPv6ConfigTable
OBJECT-TYPE
A table of IPv6 configuration options for components. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1not-accessiblemandatory
componentIPv6ConfigEntry
OBJECT-TYPE
IPv6 configuration options for a component. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1not-accessiblemandatory
componentIPv6ConfigTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentIPv6ConfigPortIndex
OBJECT-TYPE
The physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.2INTEGERread-onlymandatory
componentIPv6ConfigName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.3OCTET STRINGread-onlymandatory
componentIPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables IPv6 support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.4INTEGER {disable(0), enable(1)}read-writemandatory
componentIPv6ConfigStatic
OBJECT-TYPE
Enables/Disables IPv6 static configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
componentDHCPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables DHCPv6 address configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.6INTEGER {disable(0), enable(1)}read-writemandatory
componentIPv6ConfigStatelessEnabled
OBJECT-TYPE
Enables/Disables IPv6 stateless auto-configuration support on the component.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.1.1.7INTEGER {disable(0), enable(1)}read-writemandatory
componentIPv6ConfigTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentIPv6ConfigTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.2INTEGERread-onlymandatory
componentIPv6AddressTable
OBJECT-TYPE
A table of assigned IPv6 addresses for components. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6not-accessiblemandatory
componentIPv6AddressEntry
OBJECT-TYPE
The assigned IPv6 address for a given component. NOTE: This MIB object is not applicable to components that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1not-accessiblemandatory
componentIPv6AddressTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with multiple indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentIPv6AddressPortIndex
OBJECT-TYPE
The component's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.2INTEGERread-onlymandatory
componentIPv6AddressEntryIndex
OBJECT-TYPE
The component's address entry index.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.3INTEGERread-onlymandatory
componentIPv6AddressName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.4OCTET STRINGread-onlymandatory
componentIPv6AddressType
OBJECT-TYPE
The address type.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.5INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)}read-onlymandatory
componentIPv6Address
OBJECT-TYPE
The assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.6InetAddressIPv6read-writemandatory
componentIPv6AddressPrefixLen
OBJECT-TYPE
The prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.7INTEGER (1..128)read-writemandatory
componentIPv6AddressDefaultRoute
OBJECT-TYPE
The default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.6.1.8InetAddressIPv6read-writemandatory
componentIPv6AddressTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentIPv6AddressTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.16.11.7INTEGERread-onlymandatory
componentTimeTable
OBJECT-TYPE
Table of Component NTP Configuration.
1.3.6.1.4.1.2.3.51.2.22.32.20not-accessiblemandatory
componentTimeEntry
OBJECT-TYPE
Component NTP Configuration entry.
1.3.6.1.4.1.2.3.51.2.22.32.20.1not-accessiblemandatory
componentTimeTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.20.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentTimeName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.20.1.2OCTET STRINGread-onlymandatory
componentTimeNTPEnable
OBJECT-TYPE
This object allows the user to view the status of, and enable or disable, a component's ability to have it's NTP information updated by the CMM. NOTE: If the component either does not exist or does not support this feature, it displays 'notApplicable'.
1.3.6.1.4.1.2.3.51.2.22.32.20.1.3INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
componentTimeNTPFrequency
OBJECT-TYPE
This object allows the user to view or set the synchronization frequency (in minutes) of the NTP information update from the CMM. NOTE: If the component either does not exist or does not support this feature, it displays '0'.
1.3.6.1.4.1.2.3.51.2.22.32.20.1.4INTEGER (0..44640)read-writemandatory
componentTimeTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentTimeTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.21INTEGERread-onlymandatory
componentSolTable
OBJECT-TYPE
Component Serial-over-LAN (SOL) configuration table.
1.3.6.1.4.1.2.3.51.2.22.32.26not-accessiblemandatory
componentSolEntry
OBJECT-TYPE
Component Serial-over-LAN (SOL) configuration entry.
1.3.6.1.4.1.2.3.51.2.22.32.26.1not-accessiblemandatory
componentSolTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.32.26.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentSolName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.2OCTET STRINGread-onlymandatory
componentSolEnable
OBJECT-TYPE
Disable or enable the Serial-over-LAN (SOL) on a component.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.3INTEGER {solDisabled(0), solEnabled(1)}read-writemandatory
componentSolIpAddr
OBJECT-TYPE
This is deprecated in favor of componentSolIpAddr. IP address of the component derived from the IP address range for the system management processors on the component. NOTE: The IPv6 address for a component can be view with the componentIPv6AddressTable.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.4IpAddressread-onlydeprecated
componentSolSessionStatus
OBJECT-TYPE
Status of a Serial-over-LAN (SOL) session: solSessionNotReady: No SOL session connected to the component. solSessionReady: There is a SOL session to the component. solSessionActive: There is a SOL session to the component and there is a client using the SOL session.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.5INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)}read-onlymandatory
componentSolCapability
OBJECT-TYPE
Display whether or not the component supports the Serial-over-LAN (SOL) feature.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.6INTEGER {notSupport(0), support(1)}read-onlymandatory
componentSolIpAddr6
OBJECT-TYPE
IPv6 address of the blade.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.7InetAddressIPv6read-onlymandatory
componentSolRetryInterval
OBJECT-TYPE
Retry interval time in miliseconds.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.8INTEGERread-onlymandatory
componentSolRetryCount
OBJECT-TYPE
Retry count.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.9INTEGERread-onlymandatory
componentSolBytesSent
OBJECT-TYPE
Number of bytes sent.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.10INTEGERread-onlymandatory
componentSolBytesReceived
OBJECT-TYPE
Number of bytes received.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.11INTEGERread-onlymandatory
componentSolDestinationMAC
OBJECT-TYPE
MAC address of the blade.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.12OCTET STRINGread-onlymandatory
componentSolConsoleUserId
OBJECT-TYPE
Sol console user name.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.13OCTET STRINGread-onlymandatory
componentSolConsoleLoginFrom
OBJECT-TYPE
The location information from where the SOL console is logged in.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.14OCTET STRINGread-onlymandatory
componentSolConsoleLoginStart
OBJECT-TYPE
The time that SOL console starts.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.15OCTET STRINGread-onlymandatory
componentSolConsoleLoginEnd
OBJECT-TYPE
The time that SOL console ends.
1.3.6.1.4.1.2.3.51.2.22.32.26.1.16OCTET STRINGread-onlymandatory
componentSolTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentSolTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.32.27INTEGERread-onlymandatory
componentMonitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.37
componentSystemStatusTable
OBJECT-TYPE
Table of component status information.
1.3.6.1.4.1.2.3.51.2.22.37.1not-accessiblemandatory
componentSystemStatusEntry
OBJECT-TYPE
Component system status entry
1.3.6.1.4.1.2.3.51.2.22.37.1.1not-accessiblemandatory
componentStatusTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentStatusName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.2OCTET STRINGread-onlymandatory
componentStatusPowerState
OBJECT-TYPE
Indicates the power state of the component specified.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.3INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
componentStatusHealthState
OBJECT-TYPE
The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.4INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
componentStatusPowerEnable
OBJECT-TYPE
Power enable state for the component.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.5INTEGER {disabled(0), enabled(1)}read-onlymandatory
componentStatusWakeOnLanEnable
OBJECT-TYPE
Wake on LAN enable state for the component.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.6INTEGER {disabled(0), enabled(1), notApplicable(255)}read-onlymandatory
componentStatusWidth
OBJECT-TYPE
The width of the component including any supplement component attached to it
1.3.6.1.4.1.2.3.51.2.22.37.1.1.7INTEGERread-onlymandatory
componentStatusIOCompatibility
OBJECT-TYPE
I/O compatibility status for the component. The possible values and their meanings are as follows: unknown: This indicates a communication error for the component. ok: This is the normal (good) case where the component and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this component is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the component
1.3.6.1.4.1.2.3.51.2.22.37.1.1.21OCTET STRINGread-onlymandatory
componentStatusInventoryReady
OBJECT-TYPE
When a component management controller or the MM is reset, the component inventory data is refreshed in the MM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the MM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each component regarding the status of this information. Notes: For components that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.22INTEGER {notReady(0), ready(1)}read-onlymandatory
componentStatusBootCountPowerOnTimeBoots
OBJECT-TYPE
Blade boot count. This is valid for blade components and otherwise is undefined. Writing this value resets the boot count to zero.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.23INTEGERread-writemandatory
componentStatusBootCountPowerOnTimeSecs
OBJECT-TYPE
Blade power on time in seconds. This is valid for blade components and otherwise is undefined. Writing this value resets the power on time to zero.
1.3.6.1.4.1.2.3.51.2.22.37.1.1.24INTEGERread-writemandatory
componentSystemStatusTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentSystemStatusTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.2INTEGERread-onlymandatory
componentHealthSummaryTable
OBJECT-TYPE
Table of component health summary information. Contains information about the overall component health status. Each component contains a list of critical or warning events for that component or severity of good or none if none exist.
1.3.6.1.4.1.2.3.51.2.22.37.6not-accessiblemandatory
componentHealthSummaryEntry
OBJECT-TYPE
Component health summary entry
1.3.6.1.4.1.2.3.51.2.22.37.6.1not-accessiblemandatory
componentHealthTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.6.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentHealthEventIndex
OBJECT-TYPE
An index for the critical or warning health events for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.2INTEGER (0..255)read-onlymandatory
componentHealthSummaryName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.3OCTET STRINGread-onlymandatory
componentHealthSummarySeverity
OBJECT-TYPE
System health summary severity of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.4OCTET STRINGread-onlymandatory
componentHealthSummaryDescription
OBJECT-TYPE
System health summary description of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.5OCTET STRINGread-onlymandatory
componentHealthSummaryDateTime
OBJECT-TYPE
System health summary date time of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.6OCTET STRINGread-onlymandatory
componentHealthSummaryEventID
OBJECT-TYPE
System health summary event ID of an event for the given component.
1.3.6.1.4.1.2.3.51.2.22.37.6.1.7OCTET STRINGread-onlymandatory
componentHealthSummaryTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentHealthSummaryTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.7INTEGERread-onlymandatory
componentMACAddressTable
OBJECT-TYPE
Table of MAC address VPD information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.11not-accessiblemandatory
componentMACAddressEntry
OBJECT-TYPE
Component MAC address table entry
1.3.6.1.4.1.2.3.51.2.22.37.11.1not-accessiblemandatory
componentMACAddressTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.11.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentMACAddressIndex
OBJECT-TYPE
Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.2INTEGERread-onlymandatory
componentMACAddressName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.3OCTET STRINGread-onlymandatory
componentMACAddress
OBJECT-TYPE
The MAC address VPD value for this component and index. The value is a null terminated string. For IOMs which are members of a stack, this field is not applicable and should be disregarded.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.4OCTET STRINGread-onlymandatory
componentMACAddressTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentMACAddressTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.12INTEGERread-onlymandatory
componentUniqueIDsTable
OBJECT-TYPE
Table of unique ID information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.13not-accessiblemandatory
componentUniqueIDsEntry
OBJECT-TYPE
Component unique ID table entry
1.3.6.1.4.1.2.3.51.2.22.37.13.1not-accessiblemandatory
componentUniqueIDsTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.13.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentUniqueIDsIndex
OBJECT-TYPE
Each component may have one or more unique ID values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.13.1.2INTEGERread-onlymandatory
componentUniqueIDsName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.13.1.3OCTET STRINGread-onlymandatory
componentUniqueIDsType
OBJECT-TYPE
Type of the unique ID in the object, componentUniqueIDsValue. The type is one of the following: World Wide Name (wwn), Global Unique IDs (guid) or Serial Attach SCSI IDs (sas).
1.3.6.1.4.1.2.3.51.2.22.37.13.1.4INTEGER {wwn(1), guid(2), sas(3)}read-onlymandatory
componentUniqueIDsValue
OBJECT-TYPE
The unique ID value for this component and index. The value is a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.13.1.5OCTET STRING (SIZE(0..255))read-onlymandatory
componentUniqueIDsTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentUniqueIDsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.14INTEGERread-onlymandatory
componentVoltagesTable
OBJECT-TYPE
Table of component voltage sensor information.
1.3.6.1.4.1.2.3.51.2.22.37.16not-accessiblemandatory
componentVoltagesEntry
OBJECT-TYPE
Component voltages entry.
1.3.6.1.4.1.2.3.51.2.22.37.16.1not-accessiblemandatory
componentVoltagesTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.16.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentVoltagesSensorIndex
OBJECT-TYPE
An index for the critical or warning health events for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.2INTEGER (0..255)read-onlymandatory
componentVoltagesComponentName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.3OCTET STRINGread-onlymandatory
componentVoltagesSensorLabel
OBJECT-TYPE
The label of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.4OCTET STRINGread-onlymandatory
componentVoltagesSensorValue
OBJECT-TYPE
The value of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.5OCTET STRINGread-onlymandatory
componentVoltagesLowWarningThreshold
OBJECT-TYPE
The low warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.6OCTET STRINGread-onlymandatory
componentVoltagesHighWarningThreshold
OBJECT-TYPE
The high warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.16.1.7OCTET STRINGread-onlymandatory
componentVoltagesTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentVoltagesTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.17INTEGERread-onlymandatory
componentTemperaturesTable
OBJECT-TYPE
Table of component temperature sensor information.
1.3.6.1.4.1.2.3.51.2.22.37.21not-accessiblemandatory
componentTemperaturesEntry
OBJECT-TYPE
Component temperatures entry.
1.3.6.1.4.1.2.3.51.2.22.37.21.1not-accessiblemandatory
componentTemperaturesTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.21.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentTemperaturesSensorIndex
OBJECT-TYPE
An index for the temperature Sensors for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.2INTEGER (0..255)read-onlymandatory
componentTemperaturesComponentName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.3OCTET STRINGread-onlymandatory
componentTemperaturesSensorLabel
OBJECT-TYPE
The label of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.4OCTET STRINGread-onlymandatory
componentTemperaturesSensorValue
OBJECT-TYPE
The value of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.5OCTET STRINGread-onlymandatory
componentTemperaturesWarningThreshold
OBJECT-TYPE
The warning threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.6OCTET STRINGread-onlymandatory
componentTemperaturesShutdownThreshold
OBJECT-TYPE
The Shutdown threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.7OCTET STRINGread-onlymandatory
componentTemperaturesWarningResetThreshold
OBJECT-TYPE
The Warning Reset threshold of the sensor as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.21.1.8OCTET STRINGread-onlymandatory
componentTemperaturesTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentTemperaturesTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.22INTEGERread-onlymandatory
componentIOCompatibilityTable
OBJECT-TYPE
Table of component IO Compatibility information.
1.3.6.1.4.1.2.3.51.2.22.37.26not-accessiblemandatory
componentIOCompatibilityEntry
OBJECT-TYPE
Component IO compatibility entry.
1.3.6.1.4.1.2.3.51.2.22.37.26.1not-accessiblemandatory
componentIOCompatibilityTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.37.26.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentIOCompatibilityIOMBay
OBJECT-TYPE
An index for the IO Compatibility modules for a given component.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.2INTEGER (0..255)read-onlymandatory
componentIOCompatibilityComponentName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.3OCTET STRINGread-onlymandatory
componentIOCompatibilityIOMPower
OBJECT-TYPE
The power state of the module specified in componentIOCompatibilityIOMBay. n/a if module not installed.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.4OCTET STRINGread-onlymandatory
componentIOCompatibilityIOMFabricType
OBJECT-TYPE
The fabric type of the module specified in componentIOCompatibilityIOMBay.
1.3.6.1.4.1.2.3.51.2.22.37.26.1.5OCTET STRINGread-onlymandatory
componentIOCompatibilityFabricOnComponent
OBJECT-TYPE
The fabric type for this channel on the original component (may be onboard fabric or an expansion card).
1.3.6.1.4.1.2.3.51.2.22.37.26.1.6OCTET STRINGread-onlymandatory
componentIOCompatibilityStatus
OBJECT-TYPE
The compatibility status between the component and the module specified in componentIOCompatibilityIOMBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the component. n/a: (Not applicable) The module specified in componentIOCompatibilityIOMBay is a bridge, so the component port cannot connect to it. Attention: The module specified in componentIOCompatibilityIOMBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in componentIOCompatibilityIOMBay is of unknown type Unknown fabric type on the component
1.3.6.1.4.1.2.3.51.2.22.37.26.1.7OCTET STRINGread-onlymandatory
componentIOCompatibilityTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentIOCompatibilityTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.37.27INTEGERread-onlymandatory
nodeConnectivityTable
OBJECT-TYPE
Table of node connectivity information. This table provides information related to the node communication status.
1.3.6.1.4.1.2.3.51.2.22.37.31not-accessiblemandatory
nodeConnectivityEntry
OBJECT-TYPE
Connectivity information for nodes.
1.3.6.1.4.1.2.3.51.2.22.37.31.1not-accessiblemandatory
nodeConnectivityIndex
OBJECT-TYPE
Node Connectivity table index.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.1INTEGER (0..128)read-onlymandatory
nodeConnectivityName
OBJECT-TYPE
The name of the node as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.2OCTET STRINGread-onlymandatory
nodeConnectivityStatus
OBJECT-TYPE
Indicates the communication status of the node.
1.3.6.1.4.1.2.3.51.2.22.37.31.1.3INTEGER {notcommunicating(0), communicating(1)}read-onlymandatory
componentServiceReset
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.38
componentServiceResetTable
OBJECT-TYPE
A table providing aux power status and the ability to perform a virtual reseat or hard restart of a component.
1.3.6.1.4.1.2.3.51.2.22.38.1not-accessiblemandatory
componentServiceResetEntry
OBJECT-TYPE
Component module power service reset entry
1.3.6.1.4.1.2.3.51.2.22.38.1.1not-accessiblemandatory
componentServiceResetTopologyPath
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX, 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.38.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentServiceResetName
OBJECT-TYPE
A short text string describing the particular component. For the MM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component.
1.3.6.1.4.1.2.3.51.2.22.38.1.1.2OCTET STRINGread-onlymandatory
componentServiceResetStatus
OBJECT-TYPE
Status of the aux power. A value of auxPowerOff(0) indicates that the componant aux power is off. A value of auxPowerOn(1) indicates that the componant aux power is on.
1.3.6.1.4.1.2.3.51.2.22.38.1.1.3INTEGER {auxPowerOff(0), auxPowerOn(1), unknown(255)}read-onlymandatory
componentServiceResetCmd
OBJECT-TYPE
NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See componentStatusHealthState in componentSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the processor causing it to re-initialize. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0).
1.3.6.1.4.1.2.3.51.2.22.38.1.1.4INTEGER {noOperation(0), resetVirtualReseatOperation(1), resetHardRestartOperation(2)}read-writemandatory
componentServiceResetTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentServiceResetTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.38.2INTEGERread-onlymandatory
componentLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.39
componentLEDsTable
OBJECT-TYPE
Table of component LED information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more.
1.3.6.1.4.1.2.3.51.2.22.39.1not-accessiblemandatory
componentLEDsEntry
OBJECT-TYPE
Component LEDs information entry
1.3.6.1.4.1.2.3.51.2.22.39.1.1not-accessiblemandatory
ledComponentTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.39.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
ledComponentName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.2OCTET STRINGread-onlymandatory
ledComponentFault
OBJECT-TYPE
Indicates whether the component fault LED is on or off.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.3INTEGER {off(0), on(1)}read-onlymandatory
ledComponentCheckLog
OBJECT-TYPE
Indicates whether the component check log information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.4INTEGER {off(0), on(1)}read-writemandatory
ledComponentIdentity
OBJECT-TYPE
Indicates whether the component identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.22.39.1.1.5INTEGER {off(0), on(1), blinking(2)}read-writemandatory
componentLEDsTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentLEDsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.39.2INTEGERread-onlymandatory
componentLEDsDetailsTable
OBJECT-TYPE
Table of LED info for each component.
1.3.6.1.4.1.2.3.51.2.22.39.9not-accessiblemandatory
componentLEDsDetailsEntry
OBJECT-TYPE
Component LED info table entry
1.3.6.1.4.1.2.3.51.2.22.39.9.1not-accessiblemandatory
componentLEDsDetailsTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.22.39.9.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentLEDsDetailsIndex
OBJECT-TYPE
Each component may have one or more LEDs and data associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.2INTEGERread-onlymandatory
componentLEDsDetailsComponentType
OBJECT-TYPE
The type of the component/subcomponent grouping for this LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.3OCTET STRINGread-onlymandatory
componentLEDsDetailsLabel
OBJECT-TYPE
The text description of the LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.4OCTET STRINGread-onlymandatory
componentLEDsDetailsState
OBJECT-TYPE
The current state of the LED.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.5INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
componentLEDsDetailsLocation
OBJECT-TYPE
The physical location of this LED on the hardware.
1.3.6.1.4.1.2.3.51.2.22.39.9.1.6OCTET STRINGread-onlymandatory
componentLEDsDetailsTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentLEDsDetailsTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.22.39.10INTEGERread-onlymandatory
backupRestore
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.42
backupRestoreAction
OBJECT-TYPE
Starts the backup or restore operation. It is intended to be write-only. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.1INTEGER {backup(0), restore(1), restoreAndRestart(2)}read-writemandatory
backupRestoreStatus
OBJECT-TYPE
Get the status of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.2INTEGER {ready(0), pending(1)}read-onlymandatory
backupRestoreMessage
OBJECT-TYPE
Get the status message of the last backup/restore action which was initiated through SNMP. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.3OCTET STRINGread-onlymandatory
backupRestoreURI
OBJECT-TYPE
Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/cmd.bkp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/cmd.bkp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be:<protocol>://<hostname>/<pathname>. Note:When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.4OCTET STRING (SIZE(0..254))read-writemandatory
backupRestorePassword
OBJECT-TYPE
Password used for the encryption/decryption of the sensitive data in the backup file. It is intended to be write-only. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.5OCTET STRING (SIZE(0..63))read-writemandatory
backupRestoreLogURI
OBJECT-TYPE
Indicates the URI address where the log file will be put. It will be used only if the backupRestoreLogPush will be set on push. Contains the fully qualified remote location of the file. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file will reside, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The MM currently supports the following protocols: TFTP, FTP, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp/restore.log where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp/restore.log. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be:<protocol>://<hostname>/<pathname>. Note: When using SFTP, only an RSA fingerprint is supported. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> NOTE: This function is available only for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.6OCTET STRING (SIZE(0..254))read-writemandatory
backupRestoreLogPush
OBJECT-TYPE
Causes the restore operation to push the log to the URI address. NOTE: This can be used when restoring without restarting. NOTE: This function is only available for SNMPv3.
1.3.6.1.4.1.2.3.51.2.22.42.7INTEGER {noPush(0), push(1)}read-writemandatory
service
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23
bladeServiceData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.3
bladeServiceDataTable
OBJECT-TYPE
Table of blade service data information.
1.3.6.1.4.1.2.3.51.2.23.3.1not-accessiblemandatory
bladeServiceDataEntry
OBJECT-TYPE
Blade service data entry
1.3.6.1.4.1.2.3.51.2.23.3.1.1not-accessiblemandatory
serviceDataIndex
OBJECT-TYPE
Blade service date index.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.1INTEGERread-onlymandatory
serviceDataBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
serviceDataBladeExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
serviceDataBladePowerState
OBJECT-TYPE
Indicates whether the blade specified is powered on or not. If the MM is experiencing a communication problem with the blade, the state may be returned as unknown(255)
1.3.6.1.4.1.2.3.51.2.23.3.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
serviceDataBladeName
OBJECT-TYPE
The name of the blade as a string.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.5OCTET STRINGread-onlymandatory
serviceDataDumpInitiate
OBJECT-TYPE
Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.7INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
serviceDataDumpRetrieve
OBJECT-TYPE
Retrieve a type of service data file from blade to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.8INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
serviceDataDumpCapabilityMask
OBJECT-TYPE
Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the MM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM
1.3.6.1.4.1.2.3.51.2.23.3.1.1.9OCTET STRINGread-onlymandatory
serviceDataDumpInProgress
OBJECT-TYPE
An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.10INTEGER {inProgress(1), notInProgress(2), unknown(255)}read-onlymandatory
serviceAdvisor
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4
autoCallHomeSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.1
acceptLicenseAgreement
OBJECT-TYPE
Accept Terms and Conditions of MM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If MM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed.
1.3.6.1.4.1.2.3.51.2.23.4.1.1INTEGER {disabled(0), enabled(1)}read-writemandatory
serviceAdvisorEnable
OBJECT-TYPE
Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled.
1.3.6.1.4.1.2.3.51.2.23.4.1.2INTEGER {disabled(0), enabled(1)}read-writemandatory
serviceSupportCenter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.2
ibmSupportCenter
OBJECT-TYPE
The country code for the IBM Support Center. 2 character ISO country code.
1.3.6.1.4.1.2.3.51.2.23.4.2.1OCTET STRINGread-writemandatory
contactInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.3
companyName
OBJECT-TYPE
The organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.1OCTET STRINGread-writemandatory
contactName
OBJECT-TYPE
The name of the contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.2OCTET STRINGread-writemandatory
phoneNumber
OBJECT-TYPE
The phone of the contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.3OCTET STRINGread-writemandatory
emailAddress
OBJECT-TYPE
The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.4OCTET STRINGread-writemandatory
address
OBJECT-TYPE
The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.5OCTET STRINGread-writemandatory
city
OBJECT-TYPE
The city of the machine location. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.6OCTET STRINGread-writemandatory
state
OBJECT-TYPE
The state of the machine location. 2-3 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.7OCTET STRINGread-writemandatory
postalCode
OBJECT-TYPE
The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.2.3.51.2.23.4.3.8OCTET STRINGread-writemandatory
phoneNumberExt
OBJECT-TYPE
The phone number extension of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.9OCTET STRINGread-writemandatory
altContactName
OBJECT-TYPE
The name of the alternate contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.10OCTET STRINGread-writemandatory
altPhoneNumber
OBJECT-TYPE
The phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.11OCTET STRINGread-writemandatory
altPhoneNumberExt
OBJECT-TYPE
The phone number extension of the alternate contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.12OCTET STRINGread-writemandatory
altEmailAddress
OBJECT-TYPE
The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (130 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.13OCTET STRINGread-writemandatory
httpProxyConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.4
httpProxyEnable
OBJECT-TYPE
Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the MM to IBM. HTTP Proxy is used by the MM when it is not connected to the internet directly.
1.3.6.1.4.1.2.3.51.2.23.4.4.1INTEGER {disabled(0), enabled(1)}read-writemandatory
httpProxyLocation
OBJECT-TYPE
Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.2.3.51.2.23.4.4.2OCTET STRINGread-writemandatory
httpProxyPort
OBJECT-TYPE
The port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.2.3.51.2.23.4.4.3INTEGERread-writemandatory
httpProxyUserName
OBJECT-TYPE
User Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.4OCTET STRINGread-writemandatory
httpProxyPassword
OBJECT-TYPE
Password of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.5OCTET STRINGread-writemandatory
activityLogs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.5
activityLogTable
OBJECT-TYPE
Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home.
1.3.6.1.4.1.2.3.51.2.23.4.5.1not-accessiblemandatory
activityLogEntry
OBJECT-TYPE
Activity Log table entry. Each entry has the result of the FTP/TFTP Server attempt, the event ID, event source, date and time that event occured, and a text message.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1not-accessiblemandatory
activityLogIndex
OBJECT-TYPE
The Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1INTEGERread-onlymandatory
activityLogString
OBJECT-TYPE
A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2OCTET STRINGread-onlymandatory
activityLogAcknowledge
OBJECT-TYPE
The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via FTP/TFTP Server of Service Data.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3INTEGER {no(0), yes(1)}read-writemandatory
activityLogAttribute
OBJECT-TYPE
A string of data detailing one Activity Log entry's attribute. Status PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to FTP/TFTP Server. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The event ID, event source , date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4OCTET STRINGread-onlymandatory
autoFTPSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.5
autoFTPCallMode
OBJECT-TYPE
This field specifies the automated problem reporting mode. Automated problem reporting mode allows the MM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component.
1.3.6.1.4.1.2.3.51.2.23.5.1INTEGER {disabled(0), ftp(1), tftp(2)}read-writemandatory
autoFTPCallAddr
OBJECT-TYPE
This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.2.3.51.2.23.5.2OCTET STRINGread-writemandatory
autoFTPCallPort
OBJECT-TYPE
This field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.2.3.51.2.23.5.3INTEGERread-writemandatory
autoFTPCallUserID
OBJECT-TYPE
This field specifies the user account to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.4OCTET STRINGread-writemandatory
autoFTPCallPassword
OBJECT-TYPE
This field specifies the password to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.5OCTET STRINGread-writemandatory
callHomeExclusionEvents
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.6
readCallHomeExclusionEventTable
OBJECT-TYPE
Table of Call Home Exclusion Event entries information.
1.3.6.1.4.1.2.3.51.2.23.6.1not-accessiblemandatory
readCallHomeExclusionEventEntry
OBJECT-TYPE
Call Home Exclusion Event table entry
1.3.6.1.4.1.2.3.51.2.23.6.1.1not-accessiblemandatory
readCallHomeExclusionEventIndex
OBJECT-TYPE
The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.1INTEGERread-onlymandatory
readCallHomeExclusionEventID
OBJECT-TYPE
The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.2OCTET STRINGread-onlymandatory
addCallHomeExclusionEvent
OBJECT-TYPE
Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An Event can not be added into the exclusion list if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.2OCTET STRINGread-writemandatory
rmCallHomeExclusionEvent
OBJECT-TYPE
Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. An event on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.3OCTET STRINGread-writemandatory
rmAllCallHomeExclusionEvent
OBJECT-TYPE
Remove all Event IDs from the Call Home Exclusion List. Events on the exclusion list can not be removed if autoFtpMode is disabled. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.4INTEGER {execute(1)}read-writemandatory
componentPowerServiceReset
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.10
bladePowerServiceResetTable
OBJECT-TYPE
A table providing aux power status and the ability to perform a virtual reseat or hard restart of a blade.
1.3.6.1.4.1.2.3.51.2.23.10.1not-accessiblemandatory
bladePowerServiceResetEntry
OBJECT-TYPE
Blade power service reset entry
1.3.6.1.4.1.2.3.51.2.23.10.1.1not-accessiblemandatory
bladePowerServiceResetIndex
OBJECT-TYPE
Blade power service reset index.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.1INTEGERread-onlymandatory
bladePowerServiceResetBladeId
OBJECT-TYPE
The numeric blade slot number.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladePowerServiceResetStatus
OBJECT-TYPE
Status of the aux power. A value of auxPowerOff(0) indicates that the blade aux power is off. A value of auxPowerOn(1) indicates that the blade aux power is on.
1.3.6.1.4.1.2.3.51.2.23.10.1.1.3INTEGER {auxPowerOff(0), auxPowerOn(1)}read-onlymandatory
bladePowerServiceResetCmd
OBJECT-TYPE
NOTE: Do not perform this service reset operation on a node that is currently in a maintenance mode state. See bladeHealthState in bladeSystemStatusTable for maintMode(12) value. To reset the auxiliary power on a blade component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the blade and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For nodes, the power state will remain off and the user will need to manually power on the node. To perform a hard restart on the blade component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0).
1.3.6.1.4.1.2.3.51.2.23.10.1.1.4INTEGER {noOperation(0), resetVirtualReseatOperation(1), resetHardRestartOperation(2)}read-writemandatory
smPowerServiceResetTable
OBJECT-TYPE
A table providing aux power status and the ability to perform a virtual reseat or hard restart of a switch.
1.3.6.1.4.1.2.3.51.2.23.10.2not-accessiblemandatory
smPowerServiceResetEntry
OBJECT-TYPE
Switch module power service reset entry
1.3.6.1.4.1.2.3.51.2.23.10.2.1not-accessiblemandatory
smPowerServiceResetIndex
OBJECT-TYPE
Switch module power service reset index.
1.3.6.1.4.1.2.3.51.2.23.10.2.1.1INTEGERread-onlymandatory
smPowerServiceResetSwitchId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.23.10.2.1.2INTEGER {switch1(1), switch2(2), switch3(3), switch4(4)}read-onlymandatory
smPowerServiceResetStatus
OBJECT-TYPE
Status of the aux power power. A value of auxPowerOff(0) indicates that the switch aux power is off. A value of auxPowerOn(1) indicates that the switch aux power is on.
1.3.6.1.4.1.2.3.51.2.23.10.2.1.3INTEGER {auxPowerOff(0), auxPowerOn(1)}read-onlymandatory
smPowerServiceResetCmd
OBJECT-TYPE
To reset the auxiliary power on a switch component, set this object to resetVirtualReseatOperation(1). This will toggle the auxiliary power to the switch and simulate a physical removal and insertion. During the operation, auxiliary power is removed from the component and is then restored. For IOMs, the power state will be on after the operation completes. To perform a hard restart on the switch component, set this object to resetHardRestartOperation(2). This will toggle the reset line to the service processor causing it to re-initialize. The service processor on the component is directly reset, but the power state of the component will not be affected by this operation. This object is intended to be write-only. The component will experience a temporary loss of communication and the power state will change. Prior to executing this action, perform any operations needed to protect user data. Reading this object will always return the value of noOperation(0).
1.3.6.1.4.1.2.3.51.2.23.10.2.1.4INTEGER {noOperation(0), resetVirtualReseatOperation(1)}read-writemandatory
componentServiceData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.15
componentServiceDataTable
OBJECT-TYPE
Table of component service data information.
1.3.6.1.4.1.2.3.51.2.23.15.1not-accessiblemandatory
componentServiceDataEntry
OBJECT-TYPE
Component service data entry
1.3.6.1.4.1.2.3.51.2.23.15.1.1not-accessiblemandatory
componentServiceDataTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.23.15.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentServiceDataComponentName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.2OCTET STRINGread-onlymandatory
componentServiceDataDumpInitiate
OBJECT-TYPE
Initiates a type of dump collection to be initiated for the component and sent to the MM. NOTE: Not all components support this, please check componentServiceDataDumpCapabilityMask OID to see if the action is supported on this component. For switch modules the serviceData(4) is the only available value that can be set. When the dump file is created, the node transfers it to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.3INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
componentServiceDataDumpRetrieve
OBJECT-TYPE
Retrieve a type of service data file from component to MM. NOTE: This OID only is valid for the last four bit mask designations listed in the componentServiceDataDumpCapabilityMask OID. NOTE: This OID is not used for switch modules. The dump file is transfered to the /tftproot/service directory on the CMM. Only one file can be moved to this directory at a time, so please use the fileManagement MIB information to check if the file has been completed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.4INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
componentServiceDataDumpCapabilityMask
OBJECT-TYPE
Indicates whether the component has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the MM from the component. The values and meanings are as follows: 0000 0000 means this component does not support any at all. 0000 0001 means this component supports 'processor' type and the file remains on the component. 0000 0010 means this component supports 'platform' type and the file remains on the component. 0000 0100 means this component supports 'partition' type and the file remians on the component. 0000 1000 means this component supports 'processor' type and the file can be transferred to the MM. 0001 0000 means this component supports 'platform' type and the file can be transferred to the MM. 0010 0000 means this component supports 'partition' type and the file can be transferred to the MM 0100 0000 means this component supports 'serviceData' type and the file can be transferred to the MM For example, the returned value of 01111000 means this component supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the MM
1.3.6.1.4.1.2.3.51.2.23.15.1.1.5OCTET STRINGread-onlymandatory
componentServiceDataDumpInProgress
OBJECT-TYPE
An indicator as to whether a component dump is in progress for the specified component. This object ONLY applies to dumps that can be triggered by the MM and where the dump file is transferred to the MM filesystem upon completion. See the componentServiceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the component indicating 'init dump' and will be cleared upon receiving the valid dump file from the component or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.6INTEGER {inProgress(1), notInProgress(2), unknown(255)}read-onlymandatory
componentServiceDataStatus
OBJECT-TYPE
A status indicator for dump progress. This object ONLY applies to switch modules dumps.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.7INTEGERread-onlymandatory
componentServiceDataStatusDetails
OBJECT-TYPE
The failure status as a null terminated string. This object ONLY applies to switch modules dumps.
1.3.6.1.4.1.2.3.51.2.23.15.1.1.8OCTET STRINGread-onlymandatory
componentServiceDataTableCacheTimeout
OBJECT-TYPE
The timeout value (in seconds) of the cached data for the table, componentServiceDataTable. This value is static (constant) and cannot be set.
1.3.6.1.4.1.2.3.51.2.23.15.2INTEGERread-onlymandatory
downloadMMServiceData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.21
downloadMMServiceDataFileCreateAndDownload
OBJECT-TYPE
Specifying this string initiates the generation of the FFDC (First-Failure Data Capture) data collection (compressed group of files) for the CMM and the download of this file to the specified destination. The destination is a string of chars that specifies the remote location of service data to be saved. Use one of the following protocols: sftp, tftp, ftp, http or https. An example of a qualified location can be: <protocol>://[<user>[:password][;fingerprint=<host>]@]<host> [:<port>]/<path>/<to>/<file> Note: It is recommended that the saved-data filename have an extension of .tgz to allow support personnel to identify the file. Reading this string will always return 'Not readable' since this string may contain a password.
1.3.6.1.4.1.2.3.51.2.23.21.1OCTET STRING (SIZE(0..512))read-writemandatory
downloadMMServiceDataStatus
OBJECT-TYPE
An indicator as to whether the FFDC generation and download is in progress. To initiate this process, set the object, downloadMMServiceDataFileCreateAndDownload (see the object's description for details).
1.3.6.1.4.1.2.3.51.2.23.21.2INTEGER {ready(0), fileGenerationInProgress(1), fileDownloadInProgress(2), cancelingDownload(3)}read-onlymandatory
downloadMMServiceDataResult
OBJECT-TYPE
An indicator as to whether the FFDC generation and download was successful. The FFDC generation and download is started by setting a destination filename with the object, downloadMMServiceDataFileCreateAndDownload. If the FFDC file generation and download process completes successfully, this object is set to complete(5). If the process encounters an error, this object is set to either: permissionFailed(1), fileGenerationFailed(2) or fileDownloadFailed(3). If the process is canceled by the user, this object will be set to canceled(4). A value of none(0) is the default value. This object may be set to none(0) if the object, downloadMMServiceDataStatus, has a value of ready(0). Setting this object to any value other than none(0) will report an error.
1.3.6.1.4.1.2.3.51.2.23.21.3INTEGER {none(0), permissionFailed(1), fileGenerationFailed(2), fileDownloadFailed(3), canceled(4), complete(5)}read-writemandatory
downloadMMServiceDataCancelDownload
OBJECT-TYPE
Set this object to 'cancel(1)' to stop the FFDC file download process. 'cancel(1)' is the only valid value that may be set. The value of this object will be 'cancel(1)' if an user has set this value and an active FFDC download is in progress. After the process has been canceled, this object will automatically be set to 'none(0)'.
1.3.6.1.4.1.2.3.51.2.23.21.4INTEGER {none(0), cancel(1)}read-writemandatory
scaling
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.24
scalableComplexTable
OBJECT-TYPE
Table of scalable complex information. This table provides information related to the scalable complexes installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1not-accessiblemandatory
scalableComplexEntry
OBJECT-TYPE
Scalable complex information.
1.3.6.1.4.1.2.3.51.2.24.1.1not-accessiblemandatory
scalableComplexTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card PCI_EXPRESS, 0x32 PCI express card on (PEN) FLASH_DIMM, 0x33 Used for SPD devices that matches the silkscreen of the DIMM slot RACK, 0x50 Rack PLATFORM, 0x51 Generic Platform like rack mounted server/appliance DATAPLEX, 0x52 DataPlex OTHER, 0x53 Other unknown etc. PERIPHERAL_MODULE, 0x54 SYSTEM_BOARD, 0x55 System board PROCESSOR_MODULE, 0x56 BACK_PANEL, 0x57 POWER_SYSTEM_BOARD, 0x58 STORAGE_BACKPLANE, 0x59 Drive back plane PROC_BOARD, 0x5A Holds 1 or more processors POWER_DI, 0x5B Power mgt / power distribution board CHASSIS_BACK_PANEL, 0x5C SUB_CHASSIS, 0x5D OTHER_CHASSIS_BOARD, 0x5E DEVICE_MODULE, 0x5F REMOTE_DEVICE, 0x60 Remote mgt communication device EXTERNAL_ENVIRONMENT, 0x61 Such as external temp sensor for outside box temps PROC_MEMORY_MODULE, 0x62 Processors and memory on same module
1.3.6.1.4.1.2.3.51.2.24.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
scalableComplexIdentifier
OBJECT-TYPE
The unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1.1.2INTEGERread-onlymandatory
scalableComplexNodeName
OBJECT-TYPE
The name of the node as a null terminated string.
1.3.6.1.4.1.2.3.51.2.24.1.1.3OCTET STRINGread-onlymandatory
scalableComplexNodeHealthState
OBJECT-TYPE
The system health state for the component. Unknown: Component is in an undefined state. Good: Component is operating normally. Warning: One or more outstanding warnings exist for this component. Critical: One or more outstanding critical events for this component. Kernel Mode: Component is in kernel mode. Discovering: The MM is currently in the process of discovering this component. Communications Error: The MM failed to communicate with this component. No Power: No power to the component's domain. Flashing: Flashing in progress. Initialization Failure: Component failed to initialized. Insufficient Power: Not enough power is left in the component's domain to power the component. Power Denied: Power was denied to the component. Maintenance Mode: Node is undergoing a service operation and should not be updated or powered on/off. Firehose Dump: Node is undergoing a storage save operation and should not be udpated or powered on/off
1.3.6.1.4.1.2.3.51.2.24.1.1.4INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11), maintMode(12), firehoseDump(13)}read-onlymandatory
scalableComplexNodePowerState
OBJECT-TYPE
Indicates the power state of the node.
1.3.6.1.4.1.2.3.51.2.24.1.1.5INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
scalableComplexNodeResources
OBJECT-TYPE
A string providing a summary overview of the resources provided by this node.
1.3.6.1.4.1.2.3.51.2.24.1.1.6OCTET STRINGread-onlymandatory