MIBs Depot

CISCO-WIRELESS-DOCS-IF-MIB

Registered at
1.3.6.1.4.1.9.9.167
Last updated
2005-12-27 10:03
Organization
Cisco Systems - Wireless Engineering
Revisions
2005-12-27 10:03, 2000-06-07 10:03
Namespace
cisco
Source file
CISCO-WIRELESS-DOCS-IF-MIB
Digest
sha256:0824542011ec2e9b38ad436936650715e61e75e24bba3d2bb877c97b55468e24

Description

This is the MIB Module for MCNS compliant Radio Frequency (RF) interfaces in wireless point-to-multipoint subscriber units (SU) and wireless Head-end (HE). Glossary : The following terms are used in the MIB definitions below. MCNS : Multimedia Cable Network System P2MP : Point-Multipoint wireless system consisting of Headend (HE) and Subscriber-units (SU). HE : Head-end SU : Subscriber-unit. Attached US channel : The upstream channel on which the SU is transmitting. codeword : Data unit in a FEC (forward error correction) process. OFDM : Orthogonal Frequency Division Multiplexing. ODU : Outdoor unit (antenna). UCD : Upstream Change Descriptor. Cisco Wireless DOCSIS MIB Organization: The Cisco Wireless DOCSIS MIB provides the following categories : * Groups/Tables that are common between HE and SU * Groups/Tables that apply to SU only * Groups/Tables that apply to HE only Groups/Tables that are common between HE and SU o. cwdIfChannelTable This represents the RF channel within which upstream and downstream sub-channels operate. There will one such RF channel per point-to-multipoint interface. A RF channel identifies the portion of the RF spectrum that will be used to create a broadcast domain that will be used for communication. This channel deploys a sub-channel plan, which is used by the upstreams and downstreams. The sub-channel number for a channel is determined based on the number of sub-channels allowed and sub-channel plan version. If the maximum number of sub-channels allowed is 4 and the sub-channel plan version is 1 the spectrum can be sub divided as shown below. reference center frequency of a channel | | v +===============+ | sub 1 | The whole spectrum is used +=======+=======+ so only one sub-channel. +===============+ | 2 | 3 | The spectrum is divided into +===============+ two sub-channels. +===============+ | 2 | 6 | 7 | The spectrum is divided into +===============+ three sub-channels. +===============+ | 4 | 5 | 3 | The spectrum is divided into +===============+ three sub-channels. +===+===+===+===+ | 4 | 5 | 6 | 7 | The spectrum is divided into +===+===+===+===+ 4 sub-channels The above sub-channel planning can be extended to allow maximum number of sub-channels to be 8, 26 etc. The objects in this group are configurable only at the head-end and are read-only at the subscriber end. o. cwdIfDownstreamChannelTable This table contains the configuration information and attributes of downstream channel. The objects in this group are configurable only at the head-end and are read-only at the subscriber end. o. cwdIfUpstreamChannelTable This table contains the configuration information and attributes of upstream channel. Parameters in this table are configurable only at the Head-end, and are read-only at the SU. Only the rows that pertain to the upstream used by the subscriber unit will be available at the SU. o. cwdIfQosProfileTable This table describes the attributes of each class of service. The entries in this table are referenced from the cwdIfHeServiceEntries or cwdIfSuServiceEntries. This table is implemented at both the SU and the HE. The SU need only maintain entries for the classes of service referenced by its cwdIfSuServiceTable. o. cwdIfSignalQualityTable At the SU, this table describes the PHY signal quality of downstream channels. At the HE, it describes the PHY signal quality of upstream channels. o. cwdIfModulationTable Describes modulation parameters associated with one or more Upstream or downstream channels. Groups/Tables that apply to SU only o. cwdIfSuMacTable This table describes the attributes of each SU MAC interface, extending the information available from ifEntry. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn). o. cwdIfSuStatusTable This table maintains a number of status objects and counters for Subscriber Units. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn). o. cwdIfSuServiceTable This table describes the attributes of each upstream service queue on a SU. Groups/Tables that apply to HE only o. cwdIfHeMacTable Describes the attributes of each HE MAC interface, extending the information available from ifEntry. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn). o. cwdIfHeStatusTable For the MAC layer, this group maintains a number of status objects and counters. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn). o. cwdIfHeServiceTable This table describes the attributes of upstream service queues in a Head-end System. Entries in this table exist for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn), and for each service queue (Service ID) within this MAC layer. Entries in this table are created with the creation of individual Service IDs by the MAC layer and removed when a Service ID is removed.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: wireless-nms@cisco.com

Imports

FromSymbols
CISCO-SMIciscoMgmt
CISCO-WIRELESS-TC-MIBCwrdBm
IF-MIBInterfaceIndex, InterfaceIndexOrZero, ifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TimeInterval, TimeStamp, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-SMI
CISCO-WIRELESS-DOCS-IF-MIB
CISCO-WIRELESS-TC-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
cwdIfMibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.1
cwdIfBaseObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.1.1
cwdIfChannelTable
OBJECT-TYPE
This table describes the attributes of a channel group which consists of one or more downstream and upstream channels.
1.3.6.1.4.1.9.9.167.1.1.1not-accessiblecurrent
cwdIfChannelEntry
OBJECT-TYPE
List of attributes for a single Channel. There is one per Point-to-multipoint card. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.1.1.1not-accessiblecurrent
cwdIfChannelUpFrequency
OBJECT-TYPE
The reference center frequency used by the upstream channels in this channel.
1.3.6.1.4.1.9.9.167.1.1.1.1.1INTEGER (0..60000000)read-writecurrent
cwdIfChannelUpWidth
OBJECT-TYPE
The maximum bandwidth that can be used by any upstream channel. The sum of the bandwidths used by all upstream channels created within this channel cannot exceed this value.
1.3.6.1.4.1.9.9.167.1.1.1.1.2INTEGER (0..500000)read-writecurrent
cwdIfChannelDownFrequency
OBJECT-TYPE
The reference center frequency used by the downstream channels in this channel.
1.3.6.1.4.1.9.9.167.1.1.1.1.3INTEGER (0..60000000)read-writecurrent
cwdIfChannelDownWidth
OBJECT-TYPE
The maximum bandwidth that can be used by any downstream channel. The sum of the bandwidths used by all downstream channels created within this channel cannot exceed this value.
1.3.6.1.4.1.9.9.167.1.1.1.1.4INTEGER (0..500000)read-writecurrent
cwdIfChannelMiniSlotTimeBaseTick
OBJECT-TYPE
This object represents a unit of measurement of mini-slots. Upstream mini-slots and bandwidth allocations are done in multiples of this unit of time.
1.3.6.1.4.1.9.9.167.1.1.1.1.5INTEGER (0..102400000)read-onlycurrent
cwdIfChannelSubChannelPlanVer
OBJECT-TYPE
This object represents the sub-channel plan version number common to both upstream and downstream supported by the hardware.
1.3.6.1.4.1.9.9.167.1.1.1.1.6Unsigned32read-onlycurrent
cwdIfDownstreamChannelTable
OBJECT-TYPE
This table describes the attributes of downstream channels (frequency bands).
1.3.6.1.4.1.9.9.167.1.1.2not-accessiblecurrent
cwdIfDownstreamChannelEntry
OBJECT-TYPE
List of attributes for a single downstream channel. The index to this table is an ifIndex with an ifType of propDocsWirelessDownStream(nnn).
1.3.6.1.4.1.9.9.167.1.1.2.1not-accessiblecurrent
cwdIfDownChannelSubChannelNumber
OBJECT-TYPE
This identifies the sub-channel used by this downstream. The value of this object determines the usability of the other downstream channels.
1.3.6.1.4.1.9.9.167.1.1.2.1.1INTEGER (1..1024)read-writecurrent
cwdIfDownChannelId
OBJECT-TYPE
The internal (DOCSIS) identification of the downstream channel within this particular MAC interface. If the interface is down, the object returns the last assigned value. If the downstream channel ID is unknown, this object returns a value of 0.
1.3.6.1.4.1.9.9.167.1.1.2.1.2INTEGER (0..255)read-onlycurrent
cwdIfDownChannelFrequency
OBJECT-TYPE
The downstream center frequency associated with this channel. The channel settings determine this value.
1.3.6.1.4.1.9.9.167.1.1.2.1.3INTEGER (0..60000000)read-onlycurrent
cwdIfDownChannelWidth
OBJECT-TYPE
The bandwidth of this downstream channel. The channel settings determine this value.
1.3.6.1.4.1.9.9.167.1.1.2.1.4INTEGER (0..500000)read-onlycurrent
cwdIfDownChannelPower
OBJECT-TYPE
At the HE, the operational transmit power. At the SU, the received power level. May be set to zero at the SU if power level measurement is not supported. If the interface is down, this object returns the configured value (if at HE), the most current value (if at SU) or zero (if not supported by the implementation).
1.3.6.1.4.1.9.9.167.1.1.2.1.5Integer32 (-80..50)read-writecurrent
cwdIfDownChannelModProfileIndex
OBJECT-TYPE
An index into cwdIfModulationTable that describes modulation characteristics of this channel. This object returns 0 if the cwdIfModulationTable does not exist, or there is no corresponding row in that table that describes modulation characteristics of this channel.
1.3.6.1.4.1.9.9.167.1.1.2.1.6Unsigned32read-writecurrent
cwdIfUpstreamChannelTable
OBJECT-TYPE
Describes the attributes of attached upstream channels.
1.3.6.1.4.1.9.9.167.1.1.4not-accessiblecurrent
cwdIfUpstreamChannelEntry
OBJECT-TYPE
List of attributes for a single upstream channel. The primary index is an ifIndex with an ifType of propDocsWirelessUpstream(nnn).
1.3.6.1.4.1.9.9.167.1.1.4.1not-accessiblecurrent
cwdIfUpChannelSubChannelNumber
OBJECT-TYPE
This identifies the sub-channel used by this upstream.
1.3.6.1.4.1.9.9.167.1.1.4.1.1INTEGER (0..1024)read-writecurrent
cwdIfUpChannelId
OBJECT-TYPE
The internal (DOCSIS) identification of the upstream channel within this particular MAC interface. If the interface is down, the object returns the most current value. If the upstream channel ID is unknown, this object returns a value of 0.
1.3.6.1.4.1.9.9.167.1.1.4.1.2INTEGER (0..255)read-onlycurrent
cwdIfUpChannelFrequency
OBJECT-TYPE
The center of the upstream frequency associated with this channel. The channel settings determine this value.
1.3.6.1.4.1.9.9.167.1.1.4.1.3INTEGER (0..60000000)read-onlycurrent
cwdIfUpChannelWidth
OBJECT-TYPE
The bandwidth of this upstream channel. The channel settings determine this value.
1.3.6.1.4.1.9.9.167.1.1.4.1.4INTEGER (0..500000)read-onlycurrent
cwdIfUpChannelTargetPower
OBJECT-TYPE
The target receive power of this upstream channel at the headend and the transmit power of the channel at the subscriber end.
1.3.6.1.4.1.9.9.167.1.1.4.1.5Integer32 (-80..50)read-writecurrent
cwdIfUpChannelModProfileIndex
OBJECT-TYPE
An index into cwdIfModulationTable that describes modulation characteristics of this channel. This object returns 0 if the cwdIfModulationTable does not exist or is empty.
1.3.6.1.4.1.9.9.167.1.1.4.1.6Unsigned32read-writecurrent
cwdIfUpChannelSlotSize
OBJECT-TYPE
The number of units of time-slot (measured by cwdIfChannelMiniSlotTimeBaseTick) in each upstream mini-slot. Returns zero if the value is undefined or unknown.
1.3.6.1.4.1.9.9.167.1.1.4.1.7Unsigned32read-writecurrent
cwdIfUpChannelTxTimingOffset
OBJECT-TYPE
A measure of the current round trip time at the SU, or the maximum round trip time seen by the HE. Used for timing of SU upstream transmissions to ensure synchronized arrivals at the HE. Units are in terms of (cwdIfChannelMiniSlotTimeBaseTick/64).
1.3.6.1.4.1.9.9.167.1.1.4.1.8Unsigned32read-onlycurrent
cwdIfUpChannelRangBackoffStart
OBJECT-TYPE
This value determines the initial contention resolution back-off window used by the SU when attempting to transmit an initial ranging request. The SU randomly selects a number within the back-off window defined by this parameter then defers this number of contention transmit opportunities before actually attempting the transmission. Expressed as a power of 2. A value of 16 at the HE indicates that a proprietary adaptive retry mechanism is to be used.
1.3.6.1.4.1.9.9.167.1.1.4.1.9INTEGER (0..16)read-writecurrent
cwdIfUpChannelRangBackoffEnd
OBJECT-TYPE
This value determines the final contention resolution back-off window used by the SU when attempting to transmit an initial ranging request. The SU randomly selects a number within the back-off window defined by this parameter then defers this number of contention transmit opportunities before actually attempting the transmission. Expressed as a power of 2. A value of 16 at the HE indicates that a proprietary adaptive retry mechanism is to be used.
1.3.6.1.4.1.9.9.167.1.1.4.1.10INTEGER (0..16)read-writecurrent
cwdIfUpChannelTxBackoffStart
OBJECT-TYPE
This value determines the initial contention resolution back-off window used by the SU when attempting to transmit data packets. The SU randomly selects a number within the back-off window defined by this parameter then defers this number of contention transmit opportunities before actually attempting the transmission. Expressed as a power of 2. A value of 16 at the HE indicates that a proprietary adaptive retry mechanism is to be used.
1.3.6.1.4.1.9.9.167.1.1.4.1.11INTEGER (0..16)read-writecurrent
cwdIfUpChannelTxBackoffEnd
OBJECT-TYPE
This value determines the final contention resolution back-off window used by the SU when attempting to transmit data packets. The SU randomly selects a number within the back-off window defined by this parameter then defers this number of contention transmit opportunities before actually attempting the transmission. Expressed as a power of 2. A value of 16 at the HE indicates that a proprietary adaptive retry mechanism is to be used.
1.3.6.1.4.1.9.9.167.1.1.4.1.12INTEGER (0..16)read-writecurrent
cwdIfQosProfileTable
OBJECT-TYPE
Describes the attributes for each class of service.
1.3.6.1.4.1.9.9.167.1.1.5not-accessiblecurrent
cwdIfQosProfileEntry
OBJECT-TYPE
Describes the attributes for a single class of service. The row operation for this table is as follows: 1. This table will be implemented as read-only at the SU. SU entries are created by the agent based on information in REG-REQ MAC messages received at the SU from HE or based on information extracted from the TFTP option file 2. Creation of entries in this table is controlled by the value of cwdIfHeQosProfilePermissions. 3. There can be default entries created by the agent at the initialization time. 3. If a table is created by agent, there should only be a single entry for each Class of Service. Multiple entries with the same Class of Service parameters are not recommended as it doesn't add any extra benefit and creates extra processing of a row in the table. 4. You CAN modify a row when it is active provided you have the right cwdIfHeQosProfilePermissions. You can also change the row to notInService and change the values. An entry in this table cannot be removed while it is referenced by an entry in cwdIfSuServiceTable (Subscriber Unit) or cwdIfHeServiceTable (Head-end System). An entry in this table cannot be modified while it is referenced by an entry in cwdIfHeServiceTable. 5. If the cwdIfHeQosProfilePermissions is createBySubscriberUnits(2) then that row cannot be modified by the management system. 6. Any arbitrary integer within the range can be used as index to create a row.
1.3.6.1.4.1.9.9.167.1.1.5.1not-accessiblecurrent
cwdIfQosProfIndex
OBJECT-TYPE
The index value which uniquely identifies an entry in the cwdIfQosProfileTable. Any arbitrary integer within the range can be used as index to create a row.
1.3.6.1.4.1.9.9.167.1.1.5.1.1INTEGER (1..16383)not-accessiblecurrent
cwdIfQosProfPriority
OBJECT-TYPE
A relative priority assigned to this service when allocating bandwidth. Zero indicates lowest priority. seven highest. Interpretation of priority is device-specific.
1.3.6.1.4.1.9.9.167.1.1.5.1.2INTEGER (0..7)read-createcurrent
cwdIfQosProfMaxUpBandwidth
OBJECT-TYPE
The maximum upstream bandwidth, in bits per second, allowed for a service with this service class. Zero if there is no restriction of upstream bandwidth.
1.3.6.1.4.1.9.9.167.1.1.5.1.3INTEGER (0..100000000)read-createcurrent
cwdIfQosProfGuarUpBandwidth
OBJECT-TYPE
Minimum guaranteed upstream bandwidth, in bits per second, allowed for a service with this service class.
1.3.6.1.4.1.9.9.167.1.1.5.1.4INTEGER (0..100000000)read-createcurrent
cwdIfQosProfMaxDownBandwidth
OBJECT-TYPE
The maximum downstream bandwidth, in bits per second, allowed for a service with this service class. Zero if there is no restriction of downstream bandwidth.
1.3.6.1.4.1.9.9.167.1.1.5.1.5INTEGER (0..100000000)read-createcurrent
cwdIfQosProfMaxTxBurst
OBJECT-TYPE
The maximum number of mini-slots that may be requested for a single upstream transmission. A value of zero means there is no limit.
1.3.6.1.4.1.9.9.167.1.1.5.1.6Integer32read-createcurrent
cwdIfQosProfBaselinePrivacy
OBJECT-TYPE
Indicates whether Baseline Privacy is enabled for this service class.
1.3.6.1.4.1.9.9.167.1.1.5.1.7TruthValueread-createcurrent
cwdIfQosProfStatus
OBJECT-TYPE
Controls and reflects the status of rows in this table.
1.3.6.1.4.1.9.9.167.1.1.5.1.8RowStatusread-createcurrent
cwdIfSignalQualityTable
OBJECT-TYPE
At the SU, this table describes the PHY signal quality of downstream channels. At the HE, this table describes the PHY signal quality of upstream channels.
1.3.6.1.4.1.9.9.167.1.1.6not-accessiblecurrent
cwdIfSignalQualityEntry
OBJECT-TYPE
At the SU, describes the PHY signal quality of a downstream channel. At the HE, describes the PHY signal quality of an upstream channel. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessUpstream(nnn) for Head-End Systems and propDocsWirelessDownstream(nnn) for Subscriber units.
1.3.6.1.4.1.9.9.167.1.1.6.1not-accessiblecurrent
cwdIfSigQIncludesContention
OBJECT-TYPE
true(1) if this HE includes contention intervals in the counters in this table. Always false(2) for SUs.
1.3.6.1.4.1.9.9.167.1.1.6.1.1TruthValueread-onlycurrent
cwdIfSigQUnerroreds
OBJECT-TYPE
Codewords received on this channel without error. This includes all codewords, whether or not they were part of frames destined for this device.
1.3.6.1.4.1.9.9.167.1.1.6.1.2Counter32read-onlycurrent
cwdIfSigQCorrecteds
OBJECT-TYPE
Codewords received on this channel with correctable errors. This includes all codewords, whether or not they were part of frames destined for this device.
1.3.6.1.4.1.9.9.167.1.1.6.1.3Counter32read-onlycurrent
cwdIfSigQUncorrectables
OBJECT-TYPE
Codewords received on this channel with uncorrectable errors. This includes all codewords, whether or not they were part of frames destined for this device.
1.3.6.1.4.1.9.9.167.1.1.6.1.4Counter32read-onlycurrent
cwdIfSigQSignalNoise
OBJECT-TYPE
Signal to Interference plus Noise ratio as perceived for this channel.
1.3.6.1.4.1.9.9.167.1.1.6.1.5CwrdBmread-onlycurrent
cwdIfModulationTable
OBJECT-TYPE
Describes modulation parameters associated with one or more upstream and/or downstream channels.
1.3.6.1.4.1.9.9.167.1.1.7not-accessiblecurrent
cwdIfModulationEntry
OBJECT-TYPE
Describes a modulation profile for one or more upstream and downstream channels. Initial default entries may be created at system initialization time by the agent. The row operation for this table is as follows : 1. Any arbitrary index within the range can be used to create a row. 2. No individual non-index objects have to be specified in order to create an entry in this table. 3. CreateAndWait is not supported. 4. You can update/change the values in a row when the row is active. 5. The rows can be destroyed any time.
1.3.6.1.4.1.9.9.167.1.1.7.1not-accessiblecurrent
cwdIfModIndex
OBJECT-TYPE
An index into the Channel Modulation table (cwdIfModulationTable) representing modulation parameters of a channel.
1.3.6.1.4.1.9.9.167.1.1.7.1.1INTEGER (1..2147483647)not-accessiblecurrent
cwdIfModRowStatus
OBJECT-TYPE
Controls and reflects the status of rows in this table.
1.3.6.1.4.1.9.9.167.1.1.7.1.2RowStatusread-createcurrent
cwdIfModBandwidth
OBJECT-TYPE
The maximum bandwidth that can be used by a channel with using this modulation profile.
1.3.6.1.4.1.9.9.167.1.1.7.1.3INTEGER (0..500000)read-createcurrent
cwdIfModThroughput
OBJECT-TYPE
This represents the throughput expected of the identified radio link.
1.3.6.1.4.1.9.9.167.1.1.7.1.4INTEGER (0..50000000)read-createcurrent
cwdIfModBurstLength
OBJECT-TYPE
The duration of the OFDM burst used by the physical layer. This is also the duration of the MAC minislot. Not all the settings will be supported by a particular ODU. Consult the capabilities of the ODU to determine the best burst length setting to use. The exact durations are hardware and implementation dependent.
1.3.6.1.4.1.9.9.167.1.1.7.1.5INTEGER {veryShort(1), short(2), medium(3), long(4)}read-createcurrent
cwdIfModMultipathRobustness
OBJECT-TYPE
The quantitative level of robustness to multipath (also known as delay spread tolerance). The degree of multipath in the environment will vary with deployment. Consult installation and deployment documentation to determine the best setting to use.
1.3.6.1.4.1.9.9.167.1.1.7.1.6INTEGER {standard(1), high(2)}read-createcurrent
cwdIfSuObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.1.2
cwdIfSuMacTable
OBJECT-TYPE
Describes the attributes of each SU MAC interface, extending the information available from ifEntry.
1.3.6.1.4.1.9.9.167.1.2.1not-accessiblecurrent
cwdIfSuMacEntry
OBJECT-TYPE
An entry containing objects describing attributes of each MAC entry, extending the information in ifEntry. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.2.1.1not-accessiblecurrent
cwdIfSuHeAddress
OBJECT-TYPE
Identifies the HE that controls this MAC domain. At the SU, this will be the source address from SYNC, MAP, and other MAC-layer messages. If the HE is unknown, returns 00-00-00-00-00-00.
1.3.6.1.4.1.9.9.167.1.2.1.1.1MacAddressread-onlycurrent
cwdIfSuCapabilities
OBJECT-TYPE
Identifies the capabilities of the MAC implementation at this interface. Note that packet transmission is always supported. Therefore, there is no specific bit required to explicitly indicate this capability.
1.3.6.1.4.1.9.9.167.1.2.1.1.2Bits {atmCells(0), concatenation(1)}read-onlycurrent
cwdIfSuRangingRespTimeout
OBJECT-TYPE
Waiting time for a Ranging Response packet.
1.3.6.1.4.1.9.9.167.1.2.1.1.3TimeIntervalread-writecurrent
cwdIfSuStatusTable
OBJECT-TYPE
This table maintains a number of status objects and counters for Subscriber Units.
1.3.6.1.4.1.9.9.167.1.2.2not-accessiblecurrent
cwdIfSuStatusEntry
OBJECT-TYPE
A set of status objects and counters for a single MAC layer instance in a Subscriber unit. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.2.2.1not-accessiblecurrent
cwdIfSuStatusValue
OBJECT-TYPE
Current Subscriber unit connectivity state, as specified in the RF Interface Specification.
1.3.6.1.4.1.9.9.167.1.2.2.1.1INTEGER {other(1), notReady(2), notSynchronized(3), phySynchronized(4), usParametersAcquired(5), rangingComplete(6), ipComplete(7), todEstablished(8), securityEstablished(9), paramTransferComplete(10), registrationComplete(11), operational(12), accessDenied(13)}read-onlycurrent
cwdIfSuStatusCode
OBJECT-TYPE
Status code for this Subscriber unit as defined in the RF Interface Specification. The status code consists of a single character indicating error groups, followed by a two- or three-digit number indicating the status condition.
1.3.6.1.4.1.9.9.167.1.2.2.1.2OCTET STRINGread-onlycurrent
cwdIfSuStatusTxPower
OBJECT-TYPE
The operational transmit power for the attached upstream channel.
1.3.6.1.4.1.9.9.167.1.2.2.1.3Integer32 (-80..50)read-onlycurrent
cwdIfSuStatusResets
OBJECT-TYPE
Number of times the SU reset or initialized this interface.
1.3.6.1.4.1.9.9.167.1.2.2.1.4Counter32read-onlycurrent
cwdIfSuStatusLostSyncs
OBJECT-TYPE
Number of times the SU lost synchronization with the downstream channel.
1.3.6.1.4.1.9.9.167.1.2.2.1.5Counter32read-onlycurrent
cwdIfSuStatusInvalidMaps
OBJECT-TYPE
Number of times the SU received invalid MAP messages.
1.3.6.1.4.1.9.9.167.1.2.2.1.6Counter32read-onlycurrent
cwdIfSuStatusInvalidUcds
OBJECT-TYPE
Number of times the SU received invalid UCD messages.
1.3.6.1.4.1.9.9.167.1.2.2.1.7Counter32read-onlycurrent
cwdIfSuStatusInvalidRangingResp
OBJECT-TYPE
Number of times the SU received invalid ranging response messages.
1.3.6.1.4.1.9.9.167.1.2.2.1.8Counter32read-onlycurrent
cwdIfSuStatusInvalidRegResp
OBJECT-TYPE
Number of times the SU received invalid registration response messages.
1.3.6.1.4.1.9.9.167.1.2.2.1.9Counter32read-onlycurrent
cwdIfSuStatusT1Timeouts
OBJECT-TYPE
Number of times counter T1 expired in the SU.
1.3.6.1.4.1.9.9.167.1.2.2.1.10Counter32read-onlycurrent
cwdIfSuStatusT2Timeouts
OBJECT-TYPE
Number of times counter T2 expired in the SU.
1.3.6.1.4.1.9.9.167.1.2.2.1.11Counter32read-onlycurrent
cwdIfSuStatusT3Timeouts
OBJECT-TYPE
Number of times counter T3 expired in the SU.
1.3.6.1.4.1.9.9.167.1.2.2.1.12Counter32read-onlycurrent
cwdIfSuStatusT4Timeouts
OBJECT-TYPE
Number of times counter T4 expired in the SU.
1.3.6.1.4.1.9.9.167.1.2.2.1.13Counter32read-onlycurrent
cwdIfSuStatusRangingAborteds
OBJECT-TYPE
Number of times the ranging process was aborted by the HE.
1.3.6.1.4.1.9.9.167.1.2.2.1.14Counter32read-onlycurrent
cwdIfSuServiceTable
OBJECT-TYPE
Describes the attributes of each upstream service queue on a SU.
1.3.6.1.4.1.9.9.167.1.2.3not-accessiblecurrent
cwdIfSuServiceEntry
OBJECT-TYPE
Describes the attributes of an upstream bandwidth service queue. An entry in this table exists for each Service ID. The primary index is an ifIndex with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.2.3.1not-accessiblecurrent
cwdIfSuServiceId
OBJECT-TYPE
Identifies a service queue for upstream bandwidth. The attributes of this service queue are shared between the SU and the HE. The HE allocates upstream bandwidth to this service queue based on requests from the SU and on the class of service associated with this queue.
1.3.6.1.4.1.9.9.167.1.2.3.1.1INTEGER (1..16383)not-accessiblecurrent
cwdIfSuServiceQosProfile
OBJECT-TYPE
The index in cwdIfQosProfileTable describing the quality of service attributes associated with this particular service. If cwdIfQosProfileTable is not supported or doesn't exist, this object returns the value of zero.
1.3.6.1.4.1.9.9.167.1.2.3.1.2INTEGER (0..16383)read-onlycurrent
cwdIfSuServiceTxSlotsImmed
OBJECT-TYPE
The number of upstream mini-slots which have been used to transmit data PDUs in immediate (contention) mode. This includes only those PDUs which are presumed to have arrived at the headend (i.e., those which were explicitly acknowledged.) It does not include retransmission attempts or mini-slots used by requests.
1.3.6.1.4.1.9.9.167.1.2.3.1.3Counter32read-onlycurrent
cwdIfSuServiceTxSlotsDed
OBJECT-TYPE
The number of upstream mini-slots which have been used to transmit data PDUs in dedicated mode (i.e., as a result of a unicast Data Grant).
1.3.6.1.4.1.9.9.167.1.2.3.1.4Counter32read-onlycurrent
cwdIfSuServiceTxRetries
OBJECT-TYPE
The data PDUs transmitted directly in contention data slots expects explicit acknowledgement from the Headend. If the acknowledgement is not received the PDUs are transmitted again. This object is the number of attempts to transmit data PDUs which didn't receive acknowledgement.
1.3.6.1.4.1.9.9.167.1.2.3.1.5Counter32read-onlycurrent
cwdIfSuServiceTxExceeded
OBJECT-TYPE
The data PDUs transmitted directly in contention data slots expects explicit acknowledgement from the Headend. If the acknowledgement is not received the PDUs are transmitted again. After excessive retries the data PDUs are dropped. This object represents the number of data PDU transmission failures due to excessive retries without acknowledgment.
1.3.6.1.4.1.9.9.167.1.2.3.1.6Counter32read-onlycurrent
cwdIfSuServiceRqRetries
OBJECT-TYPE
The number of attempts to transmit bandwidth requests which did not result in acknowledgment.
1.3.6.1.4.1.9.9.167.1.2.3.1.7Counter32read-onlycurrent
cwdIfSuServiceRqExceeded
OBJECT-TYPE
The number of requests for bandwidth which failed due to excessive retries without acknowledgment.
1.3.6.1.4.1.9.9.167.1.2.3.1.8Counter32read-onlycurrent
cwdIfHeObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.1.3
cwdIfHeMacTable
OBJECT-TYPE
Describes the attributes of each HE MAC interface, extending the information available from ifEntry.
1.3.6.1.4.1.9.9.167.1.3.1not-accessiblecurrent
cwdIfHeMacEntry
OBJECT-TYPE
An entry containing objects describing attributes of each MAC entry, extending the information in ifEntry. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.3.1.1not-accessiblecurrent
cwdIfHeCapabilities
OBJECT-TYPE
Identifies the capabilities of the HE MAC implementation at this interface. Note that packet transmission is always supported. Therefore, there is no specific bit required to explicitly indicate this capability.
1.3.6.1.4.1.9.9.167.1.3.1.1.1Bits {atmCells(0), concatenation(1)}read-onlycurrent
cwdIfHeSyncInterval
OBJECT-TYPE
The interval between HE transmission of successive SYNC messages at this interface.
1.3.6.1.4.1.9.9.167.1.3.1.1.2INTEGER (1..200)read-writecurrent
cwdIfHeUcdInterval
OBJECT-TYPE
The interval between HE transmission of successive Upstream Channel Descriptor messages for each upstream channel at this interface.
1.3.6.1.4.1.9.9.167.1.3.1.1.3INTEGER (1..2000)read-writecurrent
cwdIfHeMaxServiceIds
OBJECT-TYPE
The maximum number of service IDs that may be simultaneously active.
1.3.6.1.4.1.9.9.167.1.3.1.1.4INTEGER (1..16383)read-onlycurrent
cwdIfHeInsertionInterval
OBJECT-TYPE
The amount of time between each broadcast station maintenance grant. Broadcast station maintenance grants are used to allow new subscriber units to join the network. Zero indicates that a vendor-specific algorithm is used instead of a fixed time. Maximum amount of time permitted by the DOCSIS specification is 2 seconds.
1.3.6.1.4.1.9.9.167.1.3.1.1.5TimeIntervalread-writecurrent
cwdIfHeInvitedRangingAttempts
OBJECT-TYPE
The maximum number of attempts to make on invitations for ranging requests. A value of zero means the system should attempt to range forever.
1.3.6.1.4.1.9.9.167.1.3.1.1.6INTEGER (0..1024)read-writecurrent
cwdIfHeStatusTable
OBJECT-TYPE
For the MAC layer, this group maintains a number of status objects and counters.
1.3.6.1.4.1.9.9.167.1.3.2not-accessiblecurrent
cwdIfHeStatusEntry
OBJECT-TYPE
Status entry for a single MAC layer. An entry in this table exists for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn).
1.3.6.1.4.1.9.9.167.1.3.2.1not-accessiblecurrent
cwdIfHeStatusInvalidRangeReqs
OBJECT-TYPE
This object counts invalid RNG-REQ messages received on this interface.
1.3.6.1.4.1.9.9.167.1.3.2.1.1Counter32read-onlycurrent
cwdIfHeStatusRangingAborteds
OBJECT-TYPE
This object counts ranging attempts that were explicitly aborted by the HE.
1.3.6.1.4.1.9.9.167.1.3.2.1.2Counter32read-onlycurrent
cwdIfHeStatusInvalidRegReqs
OBJECT-TYPE
This object counts invalid REG-REQ messages received on this interface.
1.3.6.1.4.1.9.9.167.1.3.2.1.3Counter32read-onlycurrent
cwdIfHeStatusFailedRegReqs
OBJECT-TYPE
This object counts failed registration attempts, i.e., authentication failures and class of service failures, on this interface.
1.3.6.1.4.1.9.9.167.1.3.2.1.4Counter32read-onlycurrent
cwdIfHeStatusInvalidDataReqs
OBJECT-TYPE
This object counts invalid data request messages received on this interface.
1.3.6.1.4.1.9.9.167.1.3.2.1.5Counter32read-onlycurrent
cwdIfHeStatusT5Timeouts
OBJECT-TYPE
This object counts the number of times counter T5 expired on this interface. The T5 timer is the 'Wait for Upstream Channel Change Response Timer' on the Head end.
1.3.6.1.4.1.9.9.167.1.3.2.1.6Counter32read-onlycurrent
cwdIfHeSuStatusTable
OBJECT-TYPE
A set of objects in the HE, maintained for each Subscriber unit connected to this HE.
1.3.6.1.4.1.9.9.167.1.3.3not-accessiblecurrent
cwdIfHeSuStatusEntry
OBJECT-TYPE
Status information for a single Subscriber unit. An entry in this table exists for each Subscriber unit that is connected to the HE implementing this table.
1.3.6.1.4.1.9.9.167.1.3.3.1not-accessiblecurrent
cwdIfHeSuStatusIndex
OBJECT-TYPE
Index value to uniquely identify an entry in this table. For an individual Subscriber Unit, this index value should not change during HE uptime.
1.3.6.1.4.1.9.9.167.1.3.3.1.1INTEGER (1..2147483647)not-accessiblecurrent
cwdIfHeSuStatusMacAddress
OBJECT-TYPE
MAC address of this Subscriber Unit. If the Subscriber Unit has multiple MAC addresses, this is the MAC address associated with the Wireless interface. Each SU has only one wireless MAC interface.
1.3.6.1.4.1.9.9.167.1.3.3.1.2MacAddressread-onlycurrent
cwdIfHeSuStatusIpAddress
OBJECT-TYPE
IP address of this Subscriber Unit. If the Subscriber Unit has no IP address assigned, or the IP address is unknown, this object returns a value of 0.0.0.0. If the Subscriber Unit has multiple IP addresses, this object returns the IP address associated with the Wireless interface. Each SU has only one wireless MAC interface.
1.3.6.1.4.1.9.9.167.1.3.3.1.3IpAddressread-onlycurrent
cwdIfHeSuStatusDownChanIfIndex
OBJECT-TYPE
IfIndex of the downstream channel this Subscriber Unit is connected to. If the downstream channel is unknown, this object returns a value of zero.
1.3.6.1.4.1.9.9.167.1.3.3.1.4InterfaceIndexOrZeroread-onlycurrent
cwdIfHeSuStatusUpChanIfIndex
OBJECT-TYPE
IfIndex of the upstream channel this Subscriber Unit is connected to. If the upstream channel is unknown, this object returns a value of zero.
1.3.6.1.4.1.9.9.167.1.3.3.1.5InterfaceIndexOrZeroread-onlycurrent
cwdIfHeSuStatusRxPower
OBJECT-TYPE
The receive power as perceived for upstream data from this subscriber unit. If the receive power is unknown, this object returns a value of zero.
1.3.6.1.4.1.9.9.167.1.3.3.1.6Integer32 (-80..33)read-onlycurrent
cwdIfHeSuStatusTimingOffset
OBJECT-TYPE
A measure of the current round trip time for this SU. Used for timing of SU upstream transmissions to ensure synchronized arrivals at the HE. Units are in terms of (cwdIfUpstreamMiniSlotTimeBaseTick/64). Returns zero if the value is unknown.
1.3.6.1.4.1.9.9.167.1.3.3.1.7Unsigned32read-onlycurrent
cwdIfHeSuStatusValue
OBJECT-TYPE
Current subscriber unit connectivity state, as specified in the RF Interface Specification. Returned status information is the SU status as assumed by the HE, and indicates the following events: other(1) Any state other than below. ranging(2) The HE has received an Initial Ranging Request message from the SU, and the ranging process is not yet complete. rangingAborted(3) The HE has sent a Ranging Abort message to the SU. rangingComplete(4) The HE has sent a Ranging Complete message to the SU. ipComplete(5) The HE has received a DHCP reply message and forwarded it to the SU. registrationComplete(6) The HE has sent a Registration Response message to the SU. accessDenied(7) The HE has sent a Registration Aborted message to the SU. The HE only needs to report states it is able to detect.
1.3.6.1.4.1.9.9.167.1.3.3.1.8INTEGER {other(1), ranging(2), rangingAborted(3), rangingComplete(4), ipComplete(5), registrationComplete(6), accessDenied(7)}read-onlycurrent
cwdIfHeSuStatusIfIndex
OBJECT-TYPE
The HE MAC interface index (ifType of propDocsWirelessMacLayer(nnn)) that SU connects to.
1.3.6.1.4.1.9.9.167.1.3.3.1.9InterfaceIndexread-onlycurrent
cwdIfHeSuStatusServiceId
OBJECT-TYPE
The SU's primary Service ID.
1.3.6.1.4.1.9.9.167.1.3.3.1.10INTEGER (1..16383)read-onlycurrent
cwdIfHeServiceTable
OBJECT-TYPE
Describes the attributes of upstream service queues in a Head-end System.
1.3.6.1.4.1.9.9.167.1.3.4not-accessiblecurrent
cwdIfHeServiceEntry
OBJECT-TYPE
Describes the attributes of a single upstream bandwidth service queue. Entries in this table exist for each ifEntry with an ifType of propDocsWirelessMacLayer(nnn), and for each service queue (Service ID) within this MAC layer. Entries in this table are created with the creation of individual Service IDs by the MAC layer and removed when a Service ID is removed.
1.3.6.1.4.1.9.9.167.1.3.4.1not-accessiblecurrent
cwdIfHeServiceId
OBJECT-TYPE
Identifies a service queue for upstream bandwidth. The attributes of this service queue are shared between the Subscriber unit and the Head-end System. The HE allocates upstream bandwidth to this service queue based on requests from the SU and on the class of service associated with this queue.
1.3.6.1.4.1.9.9.167.1.3.4.1.1INTEGER (1..16383)not-accessiblecurrent
cwdIfHeServiceSuStatusIndex
OBJECT-TYPE
Pointer to an entry in cwdIfHeSuStatusTable identifying the Subscriber unit using this Service Queue.
1.3.6.1.4.1.9.9.167.1.3.4.1.2INTEGER (0..2147483647)read-onlycurrent
cwdIfHeServiceAdminStatus
OBJECT-TYPE
Allows a service class for a particular modem to be suppressed, (re-)enabled, or deleted altogether.
1.3.6.1.4.1.9.9.167.1.3.4.1.3INTEGER {enabled(1), disabled(2), destroyed(3)}read-writecurrent
cwdIfHeServiceQosProfile
OBJECT-TYPE
The index in cwdIfQosProfileTable describing the quality of service attributes associated with this particular service. If cwdIfQosProfileTable is not supported, this object returns the value of zero.
1.3.6.1.4.1.9.9.167.1.3.4.1.4INTEGER (0..16383)read-onlycurrent
cwdIfHeServiceCreateTime
OBJECT-TYPE
The value of sysUpTime when this entry was created.
1.3.6.1.4.1.9.9.167.1.3.4.1.5TimeStampread-onlycurrent
cwdIfHeServiceInOctets
OBJECT-TYPE
The cumulative number of Packet Data octets received on this Service ID. The count does not include the size of the Wireless MAC header
1.3.6.1.4.1.9.9.167.1.3.4.1.6Counter32read-onlycurrent
cwdIfHeServiceInPackets
OBJECT-TYPE
The cumulative number of Packet Data packets received on this Service ID.
1.3.6.1.4.1.9.9.167.1.3.4.1.7Counter32read-onlycurrent
cwdIfHeQosProfilePermissions
OBJECT-TYPE
This object specifies permitted methods of creating entries in cwdIfQosProfileTable. CreateByManagement(0) is set if entries can be created using SNMP. UpdateByManagement(1) is set if updating entries using SNMP is permitted. CreateBySubscriberUnits(2) is set if entries can be created based on information in REG-REQ MAC messages received from Subscriber units. Information in this object is only applicable if cwdIfQosProfileTable is implemented as read-create. Otherwise, this object is implemented as read-only and returns CreateBySubscriberUnits(2). Either CreateByManagement(0) or CreateBySubscriberUnits(2) must be set when writing to this object. If this object has a value of createByManagement(2) the qos entries can be created and modified by the management. If this object has a value of UpdateByManagement(1) the qos entries can be updated my management irrespective of who created it. But the management cannot create new entry in the cwdIfQosProfileTable.
1.3.6.1.4.1.9.9.167.1.3.6Bits {createByManagement(0), updateByManagement(1), createBySubscriberUnits(2)}read-writecurrent
cwdIfNotification
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.2
cwdIfConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.3
cwdIfCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.3.1
cwdIfGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.167.3.2

Conformance

NameOIDStatus
cwdIfBasicCompliance
MODULE-COMPLIANCE
The compliance statement for wireless devices that implement MCNS compliant Radio Frequency Interfaces.
1.3.6.1.4.1.9.9.167.3.1.2current
cwdIfBasicGroup
OBJECT-GROUP
Group of objects implemented in both Subscriber Units and Head-end Systems.
1.3.6.1.4.1.9.9.167.3.2.1current
cwdIfSuGroup
OBJECT-GROUP
Group of objects implemented in Subscriber Units.
1.3.6.1.4.1.9.9.167.3.2.2current
cwdIfQosGroup
OBJECT-GROUP
Quality of Service related group of objects. This group is implemented in both Subscriber Units and Head-end Systems.
1.3.6.1.4.1.9.9.167.3.2.3current
cwdIfQosHeGroup
OBJECT-GROUP
Quality of Service related group of objects. This group is implemented in Head-end Systems only.
1.3.6.1.4.1.9.9.167.3.2.4current
cwdIfModGroup
OBJECT-GROUP
Objects that describe modulation characteristics of a channel. This group is implemented in both Subscriber Units and Head-end Systems.
1.3.6.1.4.1.9.9.167.3.2.5current
cwdIfHeGroup
OBJECT-GROUP
Group of objects implemented in Head-end Systems.
1.3.6.1.4.1.9.9.167.3.2.7current