MIBs Depot

CISCO-WAN-FR-X21-MIB

Registered at
1.3.6.1.4.1.351.110.4.5.1
1.3.6.1.4.1.351.110.4.5.2
1.3.6.1.4.1.351.110.4.5.3
1.3.6.1.4.1.351.150.49
Last updated
2002-09-19 00:00
Organization
Cisco Systems, Inc.
Revisions
2002-09-19 00:00
Namespace
cisco
Source file
CISCO-WAN-FR-X21-MIB
Digest
sha256:485986d6c1b65cf45ef8f6f3f61460a05ebe612ab08d0cee9ed078ce1faf5a95

Description

The MIB module to configure X.21/HSSI physical and logical interfaces. This MIB module also contains alarm configuration of X.21 interfaces. Terminologies Used: HSSI : High Speed Serial Interface. The HSSI defines both electrical and physical interfaces on DTE and DCE devices. It operates at the physical layer of the OSI reference model. This provides high-speed data communication over WAN and LAN links.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com

Imports

FromSymbols
BASIS-MIBfrPortCnfX21PortGrp, x21
CISCOWAN-SMIciscoWan
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BASIS-MIB
CISCO-WAN-FR-X21-MIB
CISCOWAN-SMI
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
x21CnfGrp
OBJECT-IDENTITY
1.3.6.1.4.1.351.110.4.5.1
x21CnfGrpTable
OBJECT-TYPE
The X21 Configuration table. The table size is given by the value of x21LineNumofValidEntries.
1.3.6.1.4.1.351.110.4.5.1.1not-accessiblecurrent
x21CnfGrpEntry
OBJECT-TYPE
An entry in the X21 Configuration table.
1.3.6.1.4.1.351.110.4.5.1.1.1not-accessiblecurrent
x21LineNum
OBJECT-TYPE
This object is the identifier of a X.21 interface. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8.
1.3.6.1.4.1.351.110.4.5.1.1.1.1Integer32 (1..8)read-onlycurrent
x21LineEnable
OBJECT-TYPE
This variable disables, enables or modifies a line 1 - disable 2 - enable 3 - modify Default is enable.
1.3.6.1.4.1.351.110.4.5.1.1.1.2INTEGER {disable(1), enable(2), modify(3)}read-writecurrent
x21LineType
OBJECT-TYPE
This variable indicates the type X21 line type. The line-type affects the clock -- the DCE device always provides the clock and DTE accepts it. dteST is only applicable to V.35 interfaces Default is DTE.
1.3.6.1.4.1.351.110.4.5.1.1.1.3INTEGER {dte(1), dce(2), dteST(3)}read-writecurrent
x21LineRate
OBJECT-TYPE
This variable configures the X.21/HSSI/V.35 line-rate. Note that enumerations 51 through 108 are supported only by FRSM-HS2/HS2B card. default is r48Kbps on FRSM-HS2B-12IN1 default is r52Mbps on FRSM-HS2/HS2B-HSSI
1.3.6.1.4.1.351.110.4.5.1.1.1.4INTEGER {r48Kbps(1), r56Kbps(2), r64Kbps(3), r112Kbps(4), r128Kbps(5), r168Kbps(6), r192Kbps(7), r224Kbps(8), r256Kbps(9), r280Kbps(10), r320Kbps(11), r336Kbps(12), r384Kbps(13), r392Kbps(14), r448Kbps(15), r512Kbps(16), r768Kbps(17), r1024Kbps(18), r1536Kbps(19), r1544Kbps(20), r1792Kbps(21), r1920Kbps(22), r1984Kbps(23), r2048Kbps(24), r3097Kbps(25), r3157Kbps(26), r4096Kbps(27), r4645Kbps(28), r4736Kbps(29), r6195Kbps(30), r6315Kbps(31), r7744Kbps(32), r7899Kbps(33), r8192Kbps(34), r9289Kbps(35), r9472Kbps(36), r10240Kbps(37), r10890Kbps(38), r11060Kbps(39), r12390Kbps(40), r12630Kbps(41), r13900Kbps(42), r14220Kbps(43), r14340Kbps(44), r15490Kbps(45), r15800Kbps(46), r16380Kbps(47), r20030Kbps(48), r24990Kbps(49), r52Mbps(50), r17370Kbps(51), r18950Kbps(52), r20530Kbps(53), r22100Kbps(54), r23680Kbps(55), r3088Kbps(56), r4632Kbps(57), r6176Kbps(58), r7720Kbps(59), r9264Kbps(60), r10808Kbps(61), r12352Kbps(62), r13896Kbps(63), r15440Kbps(64), r16984Kbps(65), r18528Kbps(66), r20072Kbps(67), r21616Kbps(68), r23160Kbps(69), r24704Kbps(70), r26248Kbps(71), r27792Kbps(72), r29336Kbps(73), r30880Kbps(74), r32424Kbps(75), r33968Kbps(76), r35512Kbps(77), r37056Kbps(78), r38600Kbps(79), r40144Kbps(80), r41688Kbps(81), r43232Kbps(82), r44776Kbps(83), r46320Kbps(84), r47864Kbps(85), r49408Kbps(86), r50952Kbps(87), r6144Kbps(88), r12288Kbps(89), r14336Kbps(90), r16384Kbps(91), r18432Kbps(92), r20480Kbps(93), r22528Kbps(94), r24576Kbps(95), r26624Kbps(96), r28672Kbps(97), r30720Kbps(98), r32768Kbps(99), r34816Kbps(100), r36864Kbps(101), r38912Kbps(102), r40960Kbps(103), r43008Kbps(104), r45056Kbps(105), r47104Kbps(106), r49152Kbps(107), r51200Kbps(108)}read-writecurrent
x21LineLoopbackCommand
OBJECT-TYPE
This variable represents the loopback state x21NoLoop Not in the loopback state. Normal traffic can be sent x21DiagnosticMetallicLoop Loopbacks the line on the back-card towards the Network. x21DiagnosticFrontcardLoop Loopbacks the line on the frontcard toward the Network. x21RemoteLoop The remote NTU is in the loop back mode. In this state, the FRSM-HS1 is sending the loopback code to remote NTU. Default is x21NoLoop. Note: Before going into one of the loopbacks the state should be x21NoLoop.
1.3.6.1.4.1.351.110.4.5.1.1.1.5INTEGER {x21NoLoop(1), x21DiagnosticMetallicLoop(2), x21DiagnosticFrontcardLoop(3), x21RemoteLoop(4), v35MetallicLoop(5)}read-writecurrent
x21LineSendCode
OBJECT-TYPE
This variable indicates what type of code is being sent across the X.21/HSSI interface by the device. The values mean: x21NoCode: No loopback. x21SendLoopACode: Start sending Loop A code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the line module of the remote device. x21SendLoopBCode: Start sending Loop B code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the digital section of the remote device. x21SendLocalLoopCode: Start sending CCITT X.21 Loopback Type 3 code. This is valid only if the backcard is X.21 type. x21SendRemoteLoopCode: Start sending CCITT X.21 Loopback Type 2 code. This is valid only if the backcard is X.21 type. x21SendUnLoopCode: Sending a loopback termination request. Valid for both HSSI and X.21 lines. To execute any of the loop-codes the x21LineLoopbackCommand should be set to x21RemoteLoop. Once the x21SendUnLoopCode succeeds the x21LineLoopbackCommand would transition back to x21NoLoop state. Default is x21NoCode.
1.3.6.1.4.1.351.110.4.5.1.1.1.6INTEGER {x21NoCode(1), x21SendLoopACode(2), x21SendLoopBCode(3), x21SendLocalLoopCode(4), x21SendRemoteLoopCode(5), x21SendUnLoopCode(6)}read-writecurrent
x21LineLoopbackCodeDetection
OBJECT-TYPE
Enable detection of line Loopback Codes. The loopback detection is implemented only in HSSI DCE mode. Default is codeDetectDisabled.
1.3.6.1.4.1.351.110.4.5.1.1.1.7INTEGER {codeDetectDisabled(1), codeDetectEnabled(2)}read-writecurrent
x21ConnectorType
OBJECT-TYPE
back card type This object is not used by FRSM-HS2/HS2B
1.3.6.1.4.1.351.110.4.5.1.1.1.8INTEGER {x21Backcard(1), hssiBackcard(2), v35Backcard(3)}read-onlycurrent
x21InvertClock
OBJECT-TYPE
This object configures two options: a) To invert the clock sent by HS1/HS2B with the TX data or not. b) If DCE,to expect the receive clock looped back from DTE or not. If DTE,to loop back the receive clock from DCE or not. nonInvertedAndNotLooped(1)- a)=dont invert, b)=dont expect rcv clock/ dont loop rcv clock invertedAndNotLooped(2) - a)=invert, b)=dont expect rcv clock/ dont loop rcv clock nonInvertedAndLooped(3) - a)=dont invert, b)=expect rcv clock/ loop rcv clock invertedAndLooped(4) - a)=invert, b)=expect rcv clock/ loop rcv clock Enums 1 and 2 are applicable for X.21/HSSI/V.35 interfaces. Enums 3 and 4 are applicable only for V.35. Default for X.21/HSSI is nonInvertedAndNotLooped(1) Default for V.35 is nonInvertedAndLooped(3) This object is not used by FRSM-HS2/FRSM-HS2B-HSSI This object is used by FRSM-HS2B-12IN1 and default values are nonInvertedAndNotLooped(1) for X.21, nonInvertedAndLooped(3) for V.35.
1.3.6.1.4.1.351.110.4.5.1.1.1.9INTEGER {nonInvertedAndNotLooped(1), invertedAndNotLooped(2), nonInvertedAndLooped(3), invertedAndLooped(4)}read-writecurrent
x21LineInterfaceType
OBJECT-TYPE
This object indicates serial interface type. Default is hssi(1). This object is not is configurable in FRSM-HS2 and FRSM-HS2B-HSSI. It will be set to hssi(1) by default for these cards This object is configurable in FRSM-H2B-12IN1. Default is v35(3).
1.3.6.1.4.1.351.110.4.5.1.1.1.10INTEGER {hssi(1), x21(2), v35(3)}read-writecurrent
x21ClkFrequencyThreshold
OBJECT-TYPE
This object indicates user configurable percentage of clock frequency, which is used by DTE clock monitoring to declare clock rate out of bound alarm. This object is valid only for X.21/v.35/HSSI DTE interfaces. This object is supported by FRSM-HS2 and FRSM-HS2/B
1.3.6.1.4.1.351.110.4.5.1.1.1.11Integer32 (1..5)read-writecurrent
serialLineRate
OBJECT-TYPE
Line rate for X.21/HSSI/V.35 interfaces in bps. This object is supported only by FRSM-HS2/B card, only multiples of 1000 are accepted. Default is 48Kbps for X.21/V.35 interfaces and 51840Kbps for HSSI interface.
1.3.6.1.4.1.351.110.4.5.1.1.1.12Integer32 (48000..51840000)read-writecurrent
serialLineRateVariation
OBJECT-TYPE
This object indicates line rate variation of HSSI/X.21/V.35 DCE interfaces in ppm (parts per million). i.e. clock generated from DCE hardware interface = (serialLineRate +/- (serialLineRateVariation * 10^6)/ serialLineRate) This object is supported only by FRSM-HS2/B card
1.3.6.1.4.1.351.110.4.5.1.1.1.13Integer32 (0..2147483647)read-onlycurrent
x21LineNumofValidEntries
OBJECT-TYPE
The number of X.21/HSSI configuration entries (regardless of their current configuration) in the x21ConfigTable table.
1.3.6.1.4.1.351.110.4.5.1.2Integer32 (1..8)read-onlycurrent
x21AlmCnfGrp
OBJECT-IDENTITY
1.3.6.1.4.1.351.110.4.5.2
x21AlmCnfGrpTable
OBJECT-TYPE
The FRSM-HS1/HS2 interface alarm configuration table.
1.3.6.1.4.1.351.110.4.5.2.1not-accessiblecurrent
x21AlmCnfGrpEntry
OBJECT-TYPE
An entry in the X.21/HSSI Alarm Configuration table.
1.3.6.1.4.1.351.110.4.5.2.1.1not-accessiblecurrent
x21AlmCnfLineNum
OBJECT-TYPE
X.21/HSSI line number. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8.
1.3.6.1.4.1.351.110.4.5.2.1.1.1Integer32 (1..8)read-writecurrent
x21Severity
OBJECT-TYPE
This variable is used to setup the severity of LOS(Loss of Signal) or clock mismatch alarm. Whenever the above condition arises, the FRSM-HS1/HS2/HS2B will send the alarm with appropriate status.
1.3.6.1.4.1.351.110.4.5.2.1.1.2INTEGER {minor(1), major(2), dontcare(3)}read-writecurrent
x21AlmGrp
OBJECT-IDENTITY
1.3.6.1.4.1.351.110.4.5.3
x21AlmGrpTable
OBJECT-TYPE
The X.21/HSSI interface alarm configuration table.
1.3.6.1.4.1.351.110.4.5.3.1not-accessiblecurrent
x21AlmGrpEntry
OBJECT-TYPE
An entry in the X21 Alarm table
1.3.6.1.4.1.351.110.4.5.3.1.1not-accessiblecurrent
x21AlmLineNum
OBJECT-TYPE
This object is the identifier (line number) of a X.21/HSSI interface. The value for this object must be same as the value of x21LineNum.
1.3.6.1.4.1.351.110.4.5.3.1.1.1Integer32 (1..8)read-onlycurrent
x21LineAlarmState
OBJECT-TYPE
This variable is a bitmap of the X21 Line ALarms on the FRSM-HS1. A value of zero indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 0 C/I signal is OFF (also used to indicate LOS) 1 Clock rate mismatch (used in DTE mode) 2 Internal Loopback (diagnostic loopback) 3 HSSI Local LoopA (line is in loopback) 4 HSSI Local LoopB (line is in loopback) 5 Remote Loopback (line is transmitting loopcodes) 6 For V35 DTE mode, DCD and CTS both are inactive 7 For V35 DCE mode, RTS is inactive 8 No cable attached to V35 backcard 9 Wrong cable attached to V35 backcard If all the bit-states are 0s: - line is not in alarm, or - line not in loopback, or - line is transmitting any loopback codes.
1.3.6.1.4.1.351.110.4.5.3.1.1.2Integer32 (0..1023)read-onlycurrent
x21LineEIAStatus
OBJECT-TYPE
Indicates the status of X.21/HSSI lines: 0x01 -- c-lead high 0x02 -- i-lead high 0x04 -- LC-lead high (valid only for HSSI DCE mode).
1.3.6.1.4.1.351.110.4.5.3.1.1.3Integer32 (0..16)read-onlycurrent
x21AlarmClrButton
OBJECT-TYPE
This variable is used to clear all the alarms for the line. 1 = No action 2 = Clear alarm.
1.3.6.1.4.1.351.110.4.5.3.1.1.4INTEGER {noaction(1), clear(2)}read-writecurrent
frPortCnfX21PortGrpTable
OBJECT-TYPE
The config table is for X.21/HSSI logical port interface
1.3.6.1.4.1.351.110.5.1.1.1.3.1not-accessiblecurrent
frPortCnfX21PortGrpEntry
OBJECT-TYPE
An entry for logical port.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1not-accessiblecurrent
x21portNum
OBJECT-TYPE
This is logical port number. The HSSI backcard can support upto 3 ports. The X.21 back card can support 4 logical ports.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.1Integer32 (1..4)read-onlycurrent
x21portLineNum
OBJECT-TYPE
This represents the line number. On FRSM-HS1 the HSSI can support 3 lines and X.21 4 lines.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.2Integer32 (1..4)read-writecurrent
x21portRowStatus
OBJECT-TYPE
This variable adds, deletes, or modifies the port 1- add 2 - delete 3 - modify Default is add.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.3INTEGER {add(1), del(2), mod(3)}read-writecurrent
x21portFlagsBetweenFrames
OBJECT-TYPE
Number of flags transmitted between two consecutive HDLC frames. Default is 1 flag.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.4Integer32 (1..10)read-writecurrent
x21portEqueueServiceRatio
OBJECT-TYPE
Number of times queue 1 is serviced for every time queue 2 is serviced. Default is 1.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.5Integer32 (1..15)read-writecurrent
x21portSpeed
OBJECT-TYPE
Port speed in kbps. At present it is same as line speed.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.6Integer32 (0..2147483647)read-onlycurrent
x21portAdmin
OBJECT-TYPE
This object is used for administratively changing the status of the port. Up/down used to up and down the port. Default is the up state.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.7INTEGER {up(1), down(2), write-Only(3)}read-writecurrent
x21portType
OBJECT-TYPE
This represents port type. The processing of the frames depends on the type of the port.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.8INTEGER {frame-relay(1), frFUNI(2), frame-forward(3)}read-writecurrent
x21portSvcStatus
OBJECT-TYPE
This represents SVC status.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.9INTEGER {disable(1), enable(2)}read-writecurrent
x21portSvcInUse
OBJECT-TYPE
This represents port SVC in use.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.10INTEGER {not-use(1), in-use(2)}read-writecurrent
x21portSvcShareLcn
OBJECT-TYPE
This represents port type.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.11INTEGER {port-based(1), card-based(2)}read-onlycurrent
x21portSvcLcnLow
OBJECT-TYPE
This represents low end of reserved LCN for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.12Integer32 (16..271)read-onlycurrent
x21portSvcLcnHigh
OBJECT-TYPE
This represents high end of reserved LCN for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.13Integer32 (16..271)read-onlycurrent
x21portSvcDlciLow
OBJECT-TYPE
This represents low end of reserved DLCI for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.14Integer32 (0..1023)read-onlycurrent
x21portSvcDlciHigh
OBJECT-TYPE
This represents high end of reserved DLCI for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.15Integer32 (0..1023)read-onlycurrent
x21portDeleteSvcs
OBJECT-TYPE
Setting this object to 1 indicates that all the SVC connections on the given port has to be deleted.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.16INTEGER {delete(1), other(2)}read-writecurrent
x21portIngrSvcBandW
OBJECT-TYPE
This represents Ingress Bandwidth reserve for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.17Integer32 (0..2147483647)read-onlycurrent
x21portEgrSvcBandW
OBJECT-TYPE
This represents Egress Bandwidth reserve for SVC.
1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.18Integer32 (0..2147483647)read-onlycurrent
cwfX21MIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.49.2
cwfX21MIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.49.2.1
cwfX21MIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.49.2.2

Conformance

NameOIDStatus
ciscoWanFrX21PortGroup
OBJECT-GROUP
The collection of objects which are applicable for X21 ports in frame relay.
1.3.6.1.4.1.351.150.49.2.1.1current
ciscoWanFrX21LineGroup
OBJECT-GROUP
The collection of objects which are related to x21 lines.
1.3.6.1.4.1.351.150.49.2.1.2current
ciscoWanFrX21AlarmConfGroup
OBJECT-GROUP
The collection of objects which are related to x21 lines.
1.3.6.1.4.1.351.150.49.2.1.3current
ciscoWanFrX21AlarmGroup
OBJECT-GROUP
The collection of objects which are related to x21 lines.
1.3.6.1.4.1.351.150.49.2.1.4current
cwfX21Compliance
MODULE-COMPLIANCE
The compliance statement for objects related to Frame Relay Ports.
1.3.6.1.4.1.351.150.49.2.2.1current