MIBs Depot

CISCO-SNA-LLC-MIB

Registered at
1.3.6.1.4.1.9.10.8
Last updated
1995-05-10 00:00
Organization
cisco IBM engineering Working Group
Revisions
1995-05-10 00:00
Namespace
cisco
Source file
CISCO-SNA-LLC-MIB
Digest
sha256:849ebc2cc3cbaf112f4111434f182a38f4cd06a6a7423d0d0cfbb0a2331b7a4b

Description

This is the MIB module for objects used to manage LLC devices.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com

Imports

FromSymbols
CISCO-SMIciscoExperiment
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TimeStamp

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-SMI
CISCO-SNA-LLC-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ciscoSnaLlcMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.1
llcPortGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.1.1
llcPortAdminTable
OBJECT-TYPE
This table contains objects that can be changed to manage an LLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation.
1.3.6.1.4.1.9.10.8.1.1.1not-accessiblecurrent
llcPortAdminEntry
OBJECT-TYPE
A list of configured values for an LLC port.
1.3.6.1.4.1.9.10.8.1.1.1.1not-accessiblecurrent
llcPortVirtualIndex
OBJECT-TYPE
This value represents a virtual LLC port. It is assigned by the agent. This value is set to 0 by the agent for interfaces identified by the ifIndex value that do not support virtual interfaces.
1.3.6.1.4.1.9.10.8.1.1.1.1.1Integer32 (0..65535)not-accessiblecurrent
llcPortAdminName
OBJECT-TYPE
An octet string that defines the virtual port to which this interface is assigned. Its value shall be unique within the administered system. It must contain only ASCII printable characters. A write operation shall not take effect until the port is cycled inactive.
1.3.6.1.4.1.9.10.8.1.1.1.1.2DisplayString (SIZE(1..8))read-writecurrent
llcPortAdminMaxSaps
OBJECT-TYPE
This parameter specifies the maximum number of SAPs that can be defined for this port.
1.3.6.1.4.1.9.10.8.1.1.1.1.3Gauge32read-writecurrent
llcPortAdminMaxCcs
OBJECT-TYPE
This parameter specifies the maximum number of connection components that can be administratively defined for this port.
1.3.6.1.4.1.9.10.8.1.1.1.1.4Gauge32read-writecurrent
llcPortAdminMaxPDUOctets
OBJECT-TYPE
This object denotes the default maximum I PDU size, in octets, that LLCs on this port may send to their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsSend object or by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
1.3.6.1.4.1.9.10.8.1.1.1.1.5Integer32read-writecurrent
llcPortAdminMaxUnackedIPDUsSend
OBJECT-TYPE
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this port may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsSend object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
1.3.6.1.4.1.9.10.8.1.1.1.1.6INTEGER (1..127)read-writecurrent
llcPortAdminMaxUnackedIPDUsRcv
OBJECT-TYPE
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsRcv object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
1.3.6.1.4.1.9.10.8.1.1.1.1.7INTEGER (1..127)read-writecurrent
llcPortAdminMaxRetransmits
OBJECT-TYPE
This object denotes the default value for the maximum number of times which LLCs on this port shall retry a PDU following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxretransmits object or by a non-zero value in the llcCcAdminMaxRetransmits object.
1.3.6.1.4.1.9.10.8.1.1.1.1.8Integer32read-writecurrent
llcPortAdminAckTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the unacknowledged frames to be retransmitted (up to N2 times). For Implementations that only use a single 'T1' Value (ref. IBM Token-Ring Network technical reference Chapter 11). This object will be used to control/read the value. This port default value may be overridden by a non-zero value in the llcSapAdminAckTimer object or by a non-zero value in the llcCcAdminAckTimer object.
1.3.6.1.4.1.9.10.8.1.1.1.1.9TimeTicksread-writecurrent
llcPortAdminPbitTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the command with the poll bit to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminPbitTimer object or by a non-zero value in the llcCcAdminPbitTimer object.
1.3.6.1.4.1.9.10.8.1.1.1.1.10TimeTicksread-writecurrent
llcPortAdminRejTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminRejTimer object or by a non-zero value in the llcCcAdminRejTimer object.
1.3.6.1.4.1.9.10.8.1.1.1.1.11TimeTicksread-writecurrent
llcPortAdminBusyTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminBusyTimer object or by a non-zero value in the llcCcAdminBusyTimer object.
1.3.6.1.4.1.9.10.8.1.1.1.1.12TimeTicksread-writecurrent
llcPortAdminInactTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture [6] Reference as the Ti parameter and is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. The value for llcPortAdminInactTimer must be much greater than the value for llcPortAdminDelayAckTimer. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminInactTimer object or by a non-zero value in the llcCcAdminInactTimer object. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
1.3.6.1.4.1.9.10.8.1.1.1.1.13TimeTicksread-writecurrent
llcPortAdminDelayAckCount
OBJECT-TYPE
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this port shall receive during the interval defined by llcCcOperDelayTimertime without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the N3 parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminDelayAckCount object or by a non-zero value in the llcCcAdminDelayCount object. A value of one indicates that acknowledgments will be sent immediately and that the value of llcPortAdminDelayAckTimer shall be ignored.
1.3.6.1.4.1.9.10.8.1.1.1.1.14Integer32read-writecurrent
llcPortAdminDelayAckTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
1.3.6.1.4.1.9.10.8.1.1.1.1.15TimeTicksread-writecurrent
llcPortAdminNw
OBJECT-TYPE
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminNw object.
1.3.6.1.4.1.9.10.8.1.1.1.1.16Integer32read-writecurrent
llcPortOperTable
OBJECT-TYPE
This table contains current LLC port parameters. Many of these objects have corresponding objects in the llcPortAdminTable.
1.3.6.1.4.1.9.10.8.1.1.2not-accessiblecurrent
llcPortOperEntry
OBJECT-TYPE
Currently set parameters for a specific LLC port.
1.3.6.1.4.1.9.10.8.1.1.2.1not-accessiblecurrent
llcPortOperMacAddress
OBJECT-TYPE
This is the MAC Address for this local port.
1.3.6.1.4.1.9.10.8.1.1.2.1.1MacAddressread-onlycurrent
llcPortOperNumSaps
OBJECT-TYPE
This object defines the number of SAPs on this port that are currently enabled. In other words, this object is a count of the number of instances of llcSapOperEntry that have a llcSapOperStatus value of 'active(2)'.
1.3.6.1.4.1.9.10.8.1.1.2.1.2Gauge32read-onlycurrent
llcPortOperHiWaterNumSaps
OBJECT-TYPE
This object reflects the highest number of SAPs active on this Port simultaneously. In other words, this object is a count of the number of instances of llcSapOperEntry on this Port.
1.3.6.1.4.1.9.10.8.1.1.2.1.3Gauge32read-onlycurrent
llcPortOperSimRim
OBJECT-TYPE
This object reflects support for transmission and receipt of SIM and RIM control frames for this port. SIM and RIM are not defined in the ANSI/IEEE 802.2 specification [5] nor in the IBM Token Ring Architecture Reference [6]. These control frames are used for the remote program load of IBM communications processors.
1.3.6.1.4.1.9.10.8.1.1.2.1.4INTEGER {no(1), yes(2)}read-onlycurrent
llcPortOperLastModifyTime
OBJECT-TYPE
This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero.
1.3.6.1.4.1.9.10.8.1.1.2.1.5TimeStampread-onlycurrent
llcPortStatsTable
OBJECT-TYPE
Each entry in this table contains statistics for a specific LLC port.
1.3.6.1.4.1.9.10.8.1.1.3not-accessiblecurrent
llcPortStatsEntry
OBJECT-TYPE
A list of statistics for an LLC port.
1.3.6.1.4.1.9.10.8.1.1.3.1not-accessiblecurrent
llcPortStatsPDUsIn
OBJECT-TYPE
This object reflects the total number of PDUs that have been received on this port. This object is initialized to zero when the port is created.
1.3.6.1.4.1.9.10.8.1.1.3.1.1Counter32read-onlycurrent
llcPortStatsPDUsOut
OBJECT-TYPE
This object reflects the total number of PDUs that have been transmitted on this port. This object is initialized to zero when the port is created.
1.3.6.1.4.1.9.10.8.1.1.3.1.2Counter32read-onlycurrent
llcPortStatsOctetsIn
OBJECT-TYPE
This object reflects the total octets received on this port. This object is initialized to zero when the port is created.
1.3.6.1.4.1.9.10.8.1.1.3.1.3Counter32read-onlycurrent
llcPortStatsOctetsOut
OBJECT-TYPE
This object reflects the total octets transmitted on this port. This object is initialized to zero when the port is created.
1.3.6.1.4.1.9.10.8.1.1.3.1.4Counter32read-onlycurrent
llcPortStatsTESTCommandsIn
OBJECT-TYPE
This object reflects the total number of TEST commands received on this port.
1.3.6.1.4.1.9.10.8.1.1.3.1.5Counter32read-onlycurrent
llcPortStatsTESTResponsesOut
OBJECT-TYPE
This object reflects the total number of TEST responses transmitted on this port in response to TEST commands received.
1.3.6.1.4.1.9.10.8.1.1.3.1.6Counter32read-onlycurrent
llcPortStatsLocalBusies
OBJECT-TYPE
This object reflects the total number of times that the local connection components on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
1.3.6.1.4.1.9.10.8.1.1.3.1.7Counter32read-onlycurrent
llcPortStatsUnknownSaps
OBJECT-TYPE
This object reflects the total number of times that a connection attempt, from a remote LLC station, for an unknown SAP was detected on this port.
1.3.6.1.4.1.9.10.8.1.1.3.1.8Counter32read-onlycurrent
llcSapGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.1.2
llcSapAdminTable
OBJECT-TYPE
This table contains objects that can be changed to manage a local SAP. Changing one of these parameters may take effect in the operating CC immediately or may wait until the interface is restarted depending on the details of the implementation.
1.3.6.1.4.1.9.10.8.1.2.1not-accessiblecurrent
llcSapAdminEntry
OBJECT-TYPE
A list of configured values for a local SAP.
1.3.6.1.4.1.9.10.8.1.2.1.1not-accessiblecurrent
llcSapNumber
OBJECT-TYPE
The address of this local SAP.
1.3.6.1.4.1.9.10.8.1.2.1.1.1INTEGER (1..255)not-accessiblecurrent
llcSapAdminMaxPDUOctets
OBJECT-TYPE
This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP may send to their remote connection component partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
1.3.6.1.4.1.9.10.8.1.2.1.1.2Integer32read-writecurrent
llcSapAdminMaxUnackedIPDUsSend
OBJECT-TYPE
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this SAP may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
1.3.6.1.4.1.9.10.8.1.2.1.1.3INTEGER (0..127)read-writecurrent
llcSapAdminMaxUnackedIPDUsRcv
OBJECT-TYPE
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
1.3.6.1.4.1.9.10.8.1.2.1.1.4INTEGER (0..127)read-writecurrent
llcSapAdminMaxRetransmits
OBJECT-TYPE
This object denotes the default value for the maximum number of times that LLCs on this SAP shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxRetransmits, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxRetransmits.
1.3.6.1.4.1.9.10.8.1.2.1.1.5Integer32read-writecurrent
llcSapAdminAckTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminAckTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminAckTimer.
1.3.6.1.4.1.9.10.8.1.2.1.1.6TimeTicksread-writecurrent
llcSapAdminPbitTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminPbitTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminPbitTimer.
1.3.6.1.4.1.9.10.8.1.2.1.1.7TimeTicksread-writecurrent
llcSapAdminRejTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminRejTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminRejTimer.
1.3.6.1.4.1.9.10.8.1.2.1.1.8TimeTicksread-writecurrent
llcSapAdminBusyTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. A zero value for this object indicates that the port default, llcPortAdminBusyTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminBusyTimer.
1.3.6.1.4.1.9.10.8.1.2.1.1.9TimeTicksread-writecurrent
llcSapAdminInactTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. A zero value for this object indicates that the port default, llcPortAdminInactTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminInactTimer. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
1.3.6.1.4.1.9.10.8.1.2.1.1.10TimeTicksread-writecurrent
llcSapAdminDelayAckCount
OBJECT-TYPE
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this SAP shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A zero value for this object indicates that the port default, llcPortAdminDelayAck, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminDelayAckCount. A value of one indicates that acknowledgments will be sent immediately and that the value of llcSapAdminDelayAckTimer shall be ignored.
1.3.6.1.4.1.9.10.8.1.2.1.1.11Integer32read-writecurrent
llcSapAdminDelayAckTimer
OBJECT-TYPE
This object denotes the default value for the time interval during which the LLCs on this SAP shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
1.3.6.1.4.1.9.10.8.1.2.1.1.12TimeTicksread-writecurrent
llcSapAdminNw
OBJECT-TYPE
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This SAP default value may be overridden by a non-zero Cc default value in the llcCcAdminNw object.
1.3.6.1.4.1.9.10.8.1.2.1.1.13Integer32read-writecurrent
llcSapOperTable
OBJECT-TYPE
This table contains objects that reflect the current operational parameters of a local SAP.
1.3.6.1.4.1.9.10.8.1.2.2not-accessiblecurrent
llcSapOperEntry
OBJECT-TYPE
A list of configured values for a local SAP.
1.3.6.1.4.1.9.10.8.1.2.2.1not-accessiblecurrent
llcSapOperStatus
OBJECT-TYPE
This parameter describes the actual state of this local SAP.
1.3.6.1.4.1.9.10.8.1.2.2.1.1INTEGER {inactive(1), active(2)}read-onlycurrent
llcSapOperNumCcs
OBJECT-TYPE
This object defines the number of connection components on this SAP that are currently in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)'.
1.3.6.1.4.1.9.10.8.1.2.2.1.2Integer32read-onlycurrent
llcSapOperHiWaterNumCcs
OBJECT-TYPE
This object reflects the highest number of connection components on this SAP simultaneously in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)' concurrently on this SAP.
1.3.6.1.4.1.9.10.8.1.2.2.1.3Gauge32read-onlycurrent
llcSapOperLlc2Support
OBJECT-TYPE
This parameter describes whether or not the LLC implementation supports LLC2 connection components.
1.3.6.1.4.1.9.10.8.1.2.2.1.4INTEGER {no(1), yes(2)}read-onlycurrent
llcSapStatsTable
OBJECT-TYPE
This table contains objects that reflect the current operational parameters of a local SAP.
1.3.6.1.4.1.9.10.8.1.2.3not-accessiblecurrent
llcSapStatsEntry
OBJECT-TYPE
A list of configured values for a local SAP.
1.3.6.1.4.1.9.10.8.1.2.3.1not-accessiblecurrent
llcSapStatsLocalBusies
OBJECT-TYPE
This object reflects the total number of times that the local connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.1Counter32read-onlycurrent
llcSapStatsRemoteBusies
OBJECT-TYPE
This object reflects the total number of times that the adjacent (i.e. remote) connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.2Counter32read-onlycurrent
llcSapStatsIFramesIn
OBJECT-TYPE
This object reflects the total number of I-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.3Counter32read-onlycurrent
llcSapStatsIFramesOut
OBJECT-TYPE
This object reflects the total number of I-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.4Counter32read-onlycurrent
llcSapStatsIOctetsIn
OBJECT-TYPE
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.5Counter32read-onlycurrent
llcSapStatsIOctetsOut
OBJECT-TYPE
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.6Counter32read-onlycurrent
llcSapStatsSFramesIn
OBJECT-TYPE
This object reflects the total number of S-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
1.3.6.1.4.1.9.10.8.1.2.3.1.7Counter32read-onlycurrent
llcSapStatsSFramesOut
OBJECT-TYPE
This object reflects the total number of S-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
1.3.6.1.4.1.9.10.8.1.2.3.1.8Counter32read-onlycurrent
llcSapStatsRetransmitsOut
OBJECT-TYPE
This object reflects the total number of I-Frames retransmitted by all local connection components on this SAP. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.9Counter32read-onlycurrent
llcSapStatsREJsIn
OBJECT-TYPE
This object reflects the total REJ frames received from all adjacent LLC connection components on this SAP since it was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.10Counter32read-onlycurrent
llcSapStatsREJsOut
OBJECT-TYPE
This object reflects the total REJ frames transmitted to an adjacent LLC connection components on this SAP since it was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.11Counter32read-onlycurrent
llcSapStatsWwCount
OBJECT-TYPE
This object reflects the total number of times, since this SAP was created, that the dynamic window algorithm has been invoked to reduce the value of Ww on any of the connection components of this SAP. This object is initialized to zero when the SAP is created. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
1.3.6.1.4.1.9.10.8.1.2.3.1.12Counter32read-onlycurrent
llcSapStatsTESTCommandsIn
OBJECT-TYPE
This object denotes the number of TEST commands this SAP has received and is a measure of the number of stations in the network trying to connect up. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.13Counter32read-onlycurrent
llcSapStatsTESTCommandsOut
OBJECT-TYPE
This object denotes the number of TEST commands this SAP has sent and is a measure of the number of other stations we are trying to connect to. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.14Counter32read-onlycurrent
llcSapStatsTESTResponsesIn
OBJECT-TYPE
This object denotes the number of TEST responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.15Counter32read-onlycurrent
llcSapStatsTESTResponsesOut
OBJECT-TYPE
This object denotes the number of TEST responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.16Counter32read-onlycurrent
llcSapStatsXIDCommandsIn
OBJECT-TYPE
This object denotes the number of XID commands this SAP has received and is a measure of the number of stations in the network trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.17Counter32read-onlycurrent
llcSapStatsXIDCommandsOut
OBJECT-TYPE
This object denotes the number of XID commands this SAP has sent and is a measure of the number of other stations this SAP is trying to connect to. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.18Counter32read-onlycurrent
llcSapStatsXIDResponsesIn
OBJECT-TYPE
This object denotes the number of XID responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.19Counter32read-onlycurrent
llcSapStatsXIDResponsesOut
OBJECT-TYPE
This object denotes the number of XID responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.20Counter32read-onlycurrent
llcSapStatsUIFramesIn
OBJECT-TYPE
This object reflects the total number of unnumbered information (UI) frames received on a local SAP.
1.3.6.1.4.1.9.10.8.1.2.3.1.21Counter32read-onlycurrent
llcSapStatsUIFramesOut
OBJECT-TYPE
This object reflects the total number of unnumbered information (UI) frames sent on a local SAP.
1.3.6.1.4.1.9.10.8.1.2.3.1.22Counter32read-onlycurrent
llcSapStatsUIOctetsIn
OBJECT-TYPE
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.23Counter32read-onlycurrent
llcSapStatsUIOctetsOut
OBJECT-TYPE
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
1.3.6.1.4.1.9.10.8.1.2.3.1.24Counter32read-onlycurrent
llcSapStatsConnectOk
OBJECT-TYPE
This object reflects the total number of successful connections that have been established on this SAP since the SAP was created. A successful connection is indicated by a successful SABME/UA exchange.
1.3.6.1.4.1.9.10.8.1.2.3.1.25Counter32read-onlycurrent
llcSapStatsConnectFail
OBJECT-TYPE
This object reflects the total number of unsuccessful connections that have been attempted on this SAP since the SAP was created. An unsuccessful connection attempt is indicated by a SABME/DM exchange or a SABME/timeout.
1.3.6.1.4.1.9.10.8.1.2.3.1.26Counter32read-onlycurrent
llcSapStatsDisconnect
OBJECT-TYPE
This object reflects the total number of normal disconnections that have been performed on this SAP since the SAP was created. A normal disconnection is indicated by a successful DISC/UA exchange or merely a DISC sent or received.
1.3.6.1.4.1.9.10.8.1.2.3.1.27Counter32read-onlycurrent
llcSapStatsDisconnectFRMRSend
OBJECT-TYPE
This object reflects the total number of abnormal disconnections (resulting from a FRMR being sent) that have been performed on this SAP since the SAP was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.28Counter32read-onlycurrent
llcSapStatsDisconnectFRMRRcv
OBJECT-TYPE
This object reflects the total number of abnormal disconnections (resulting from a FRMR being received) that have been performed on this SAP since the SAP was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.29Counter32read-onlycurrent
llcSapStatsDisconnectTimer
OBJECT-TYPE
This object reflects the total number of abnormal disconnections (resulting from a timer expiration) that have been performed on this SAP since the SAP was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.30Counter32read-onlycurrent
llcSapStatsDMsInABM
OBJECT-TYPE
This object reflects the total number of Disconnect Mode responses that have been received for CCs in ABM mode on this SAP since the SAP was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.31Counter32read-onlycurrent
llcSapStatsSABMEsInABM
OBJECT-TYPE
This object reflects the total number of SABMEs that have been received for CCs in already in ABM mode on this SAP since the SAP was created.
1.3.6.1.4.1.9.10.8.1.2.3.1.32Counter32read-onlycurrent
llcCcGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.1.3
llcCcAdminTable
OBJECT-TYPE
This table contains objects that can be changed to manage an LLC connection component. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in llcCcAdminTable can be created either by an agent or a management station. The management station can create an entry in llcCcAdminTable by setting the appropriate value in llcCcAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the llcCcOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started.
1.3.6.1.4.1.9.10.8.1.3.1not-accessiblecurrent
llcCcAdminEntry
OBJECT-TYPE
A list of configured values for an LLC connection component.
1.3.6.1.4.1.9.10.8.1.3.1.1not-accessiblecurrent
llcCcRMac
OBJECT-TYPE
This value is the remote MAC address for this Connection Component. This value is provided by the SNMP agent.
1.3.6.1.4.1.9.10.8.1.3.1.1.1MacAddressnot-accessiblecurrent
llcCcRSap
OBJECT-TYPE
This value is the address of the remote SAP for this Connection Component. This value is provided by the SNMP agent.
1.3.6.1.4.1.9.10.8.1.3.1.1.2INTEGER (1..255)not-accessiblecurrent
llcCcAdminBounce
OBJECT-TYPE
This object controls the resetting of the connection component. Setting this value to yes(2) results in the connection component being reset, llcCcOperState transitioning to a value of aDm(1), and the value of llcCcAdminBounce being set back to no(1).
1.3.6.1.4.1.9.10.8.1.3.1.1.3INTEGER {no(1), yes(2)}read-createcurrent
llcCcAdminMaxPDUOctets
OBJECT-TYPE
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
1.3.6.1.4.1.9.10.8.1.3.1.1.4Integer32read-createcurrent
llcCcAdminMaxUnackedIPDUsSend
OBJECT-TYPE
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
1.3.6.1.4.1.9.10.8.1.3.1.1.5INTEGER (0..127)read-createcurrent
llcCcAdminMaxUnackedIPDUsRcv
OBJECT-TYPE
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
1.3.6.1.4.1.9.10.8.1.3.1.1.6INTEGER (0..127)read-createcurrent
llcCcAdminMaxRetransmits
OBJECT-TYPE
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxRetransmits, shall be used.
1.3.6.1.4.1.9.10.8.1.3.1.1.7Integer32read-createcurrent
llcCcAdminAckTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminAckTimer, shall be used.
1.3.6.1.4.1.9.10.8.1.3.1.1.8TimeTicksread-createcurrent
llcCcAdminPbitTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminPbitTimer, shall be used.
1.3.6.1.4.1.9.10.8.1.3.1.1.9TimeTicksread-createcurrent
llcCcAdminRejTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminRejTimer, shall be used.
1.3.6.1.4.1.9.10.8.1.3.1.1.10TimeTicksread-createcurrent
llcCcAdminBusyTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminBusyTimer, shall be used.
1.3.6.1.4.1.9.10.8.1.3.1.1.11TimeTicksread-createcurrent
llcCcAdminInactTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminInactTimer, shall be used. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
1.3.6.1.4.1.9.10.8.1.3.1.1.12TimeTicksread-createcurrent
llcCcAdminDelayAckCount
OBJECT-TYPE
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminDelayAck, shall be used. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcAdminDelayAckTimer shall be ignored.
1.3.6.1.4.1.9.10.8.1.3.1.1.13Integer32read-createcurrent
llcCcAdminDelayAckTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object contains an administrative value which will be applied the next time this connection is established. This object is associated with the llcCcAdminDelayAckCount object and is only defined if that object has a value greater than one.
1.3.6.1.4.1.9.10.8.1.3.1.1.14TimeTicksread-createcurrent
llcCcAdminNw
OBJECT-TYPE
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented.
1.3.6.1.4.1.9.10.8.1.3.1.1.15Integer32read-createcurrent
llcCcAdminRowStatus
OBJECT-TYPE
This object is used by a management station to create or delete the row entry in llcCcAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the llcCcOperTable with llcCcOperState equal to 'aDM (1)'.
1.3.6.1.4.1.9.10.8.1.3.1.1.16RowStatusread-createcurrent
llcCcOperTable
OBJECT-TYPE
This table contains current LLC link parameters. Many of these objects have corresponding objects in the llcCcAdminTable.
1.3.6.1.4.1.9.10.8.1.3.2not-accessiblecurrent
llcCcOperEntry
OBJECT-TYPE
A list of status and control values for an LLC connection component.
1.3.6.1.4.1.9.10.8.1.3.2.1not-accessiblecurrent
llcCcOperState
OBJECT-TYPE
This object describes the operational state of the LLC connection. If the connection component is disabled, llcCcOperState will transition to aDM(1). If the connection component is enabled, llcCcOperState will transition to normal(3).
1.3.6.1.4.1.9.10.8.1.3.2.1.1INTEGER {aDM(1), setup(2), normal(3), busy(4), reject(5), await(6), awaitBusy(7), awaitReject(8), dConn(9), reset(10), error(11), conn(12), resetCheck(13), resetWait(14)}read-onlycurrent
llcCcOperMaxIPDUOctetsSend
OBJECT-TYPE
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect that in this object. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
1.3.6.1.4.1.9.10.8.1.3.2.1.2Integer32read-onlycurrent
llcCcOperMaxIPDUOctetsRcv
OBJECT-TYPE
This object denotes the maximum I PDU size, in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5] The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
1.3.6.1.4.1.9.10.8.1.3.2.1.3Integer32read-onlycurrent
llcCcOperMaxUnackedIPDUsSend
OBJECT-TYPE
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect that in this object.
1.3.6.1.4.1.9.10.8.1.3.2.1.4INTEGER (1..127)read-onlycurrent
llcCcOperMaxUnackedIPDUsRcv
OBJECT-TYPE
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5].
1.3.6.1.4.1.9.10.8.1.3.2.1.5INTEGER (1..127)read-onlycurrent
llcCcOperMaxRetransmits
OBJECT-TYPE
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5].
1.3.6.1.4.1.9.10.8.1.3.2.1.6Integer32read-onlycurrent
llcCcOperAckTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times).
1.3.6.1.4.1.9.10.8.1.3.2.1.7TimeTicksread-onlycurrent
llcCcOperPbitTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
1.3.6.1.4.1.9.10.8.1.3.2.1.8TimeTicksread-onlycurrent
llcCcOperRejTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
1.3.6.1.4.1.9.10.8.1.3.2.1.9TimeTicksread-onlycurrent
llcCcOperBusyTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive.
1.3.6.1.4.1.9.10.8.1.3.2.1.10TimeTicksread-onlycurrent
llcCcOperInactTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
1.3.6.1.4.1.9.10.8.1.3.2.1.11TimeTicksread-onlycurrent
llcCcOperDelayAckCount
OBJECT-TYPE
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcOperDelayAckTimer should be ignored.
1.3.6.1.4.1.9.10.8.1.3.2.1.12Integer32read-onlycurrent
llcCcOperDelayAckTimer
OBJECT-TYPE
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcCcOperDelayAckCount object and only has meaning if that object has a value greater than one.
1.3.6.1.4.1.9.10.8.1.3.2.1.13TimeTicksread-onlycurrent
llcCcOperNw
OBJECT-TYPE
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
1.3.6.1.4.1.9.10.8.1.3.2.1.14Integer32read-onlycurrent
llcCcOperWw
OBJECT-TYPE
Maximum number of sequentially numbered IPDUs that the connection component may have outstanding (unacknowledged) at any given time. Ww is initialized to the value of llcCcOperMaxUnackedIPDUsSend when the link is established. When the dynamic window algorithm is invoked, Ww varies from 1 up to llcCcOperMaxUnackedIPDUsSend. Each time the llcCcOperWw value is decreased, the reason is recorded in llcCcOperLastWwCause, and llcCcStatWwCount is incremented by 1. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
1.3.6.1.4.1.9.10.8.1.3.2.1.15INTEGER (1..127)read-onlycurrent
llcCcOperCreateTime
OBJECT-TYPE
This object describes the value of sysUpTime when this connection was created.
1.3.6.1.4.1.9.10.8.1.3.2.1.16TimeStampread-onlycurrent
llcCcOperLastModifyTime
OBJECT-TYPE
This object describes the value of sysUpTime the last time this connection component was modified. If the connection has not been modified, then this value shall be zero.
1.3.6.1.4.1.9.10.8.1.3.2.1.17TimeStampread-onlycurrent
llcCcOperLastFailTime
OBJECT-TYPE
This object describes the value of sysUpTime when this LLC connection component last failed. If the connection component has not failed, then this value shall be zero.
1.3.6.1.4.1.9.10.8.1.3.2.1.18TimeStampread-onlycurrent
llcCcOperLastFailCause
OBJECT-TYPE
This enumerated object reflects the cause of the last failure of this LLC connection component. If the connection component has not failed, then this object will have a value of undefined(1).
1.3.6.1.4.1.9.10.8.1.3.2.1.19INTEGER {undefined(1), rxFRMR(2), txFRMR(3), discReceived(4), discSent(5), retriesExpired(6), forcedShutdown(7)}read-onlycurrent
llcCcOperLastFailFRMRInfo
OBJECT-TYPE
This object reflects the information field of the FRMR frame if the last failure for this LLC connection component was as a result of an invalid frame. Otherwise, this field has no meaning.
1.3.6.1.4.1.9.10.8.1.3.2.1.20OCTET STRING (SIZE(3))read-onlycurrent
llcCcOperLastWwCause
OBJECT-TYPE
This object indicates the reason that the llcCcOperWw was reduced the last time this occurred.
1.3.6.1.4.1.9.10.8.1.3.2.1.21INTEGER {neverInvoked(1), lostData(2), macLayerCongestion(3), other(4)}read-onlycurrent
llcCcStatsTable
OBJECT-TYPE
Each entry in this table contains statistics for a specific LLC connection component.
1.3.6.1.4.1.9.10.8.1.3.3not-accessiblecurrent
llcCcStatsEntry
OBJECT-TYPE
A list of statistics for an LLC connection component.
1.3.6.1.4.1.9.10.8.1.3.3.1not-accessiblecurrent
llcCcStatsLocalBusies
OBJECT-TYPE
This object reflects the total number of times that the local connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.1Counter32read-onlycurrent
llcCcStatsRemoteBusies
OBJECT-TYPE
This object reflects the total number of times that the adjacent (i.e. remote) connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.2Counter32read-onlycurrent
llcCcStatsIFramesIn
OBJECT-TYPE
This object reflects the total number of I-Frames that have been received by the connection component. This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.3Counter32read-onlycurrent
llcCcStatsIFramesOut
OBJECT-TYPE
This object reflects the total number of I-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.4Counter32read-onlycurrent
llcCcStatsIOctetsIn
OBJECT-TYPE
This object reflects the total octets received from the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.5Counter32read-onlycurrent
llcCcStatsIOctetsOut
OBJECT-TYPE
This object reflects the total octets transmitted to the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.6Counter32read-onlycurrent
llcCcStatsSFramesIn
OBJECT-TYPE
This object reflects the total number of S-Frames that have been received by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
1.3.6.1.4.1.9.10.8.1.3.3.1.7Counter32read-onlycurrent
llcCcStatsSFramesOut
OBJECT-TYPE
This object reflects the total number of S-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
1.3.6.1.4.1.9.10.8.1.3.3.1.8Counter32read-onlycurrent
llcCcStatsRetransmitsOut
OBJECT-TYPE
This object reflects the total number of I-Frames retransmitted the local connection component. This object is initialized to zero when the connection component is created.
1.3.6.1.4.1.9.10.8.1.3.3.1.9Counter32read-onlycurrent
llcCcStatsREJsIn
OBJECT-TYPE
This object reflects the total REJ frames received from an adjacent LLC connection component since connection component startup.
1.3.6.1.4.1.9.10.8.1.3.3.1.10Counter32read-onlycurrent
llcCcStatsREJsOut
OBJECT-TYPE
This object reflects the total REJ frames transmitted to an adjacent LLC connection component since connection component startup.
1.3.6.1.4.1.9.10.8.1.3.3.1.11Counter32read-onlycurrent
llcCcStatsWwCount
OBJECT-TYPE
This object reflects the total number of times, since connection component startup, that the dynamic window algorithm has been invoked to reduce the value of Ww. At connection component startupm this object must be initialized to zero. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
1.3.6.1.4.1.9.10.8.1.3.3.1.12Counter32read-onlycurrent
snaLlcMIBNotificationPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.2
snaLlcMIBNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.2.0
snaLlcMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.3
snaLlcMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.3.1
snaLlcMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.8.3.2

Notifications

NameOIDStatus
llcCcStatusChange
NOTIFICATION-TYPE
This trap indicates that the state of an LLC connection component has transitioned to normal(3) or aDM(1).
1.3.6.1.4.1.9.10.8.2.0.1current

Conformance

NameOIDStatus
llcCoreCompliance
MODULE-COMPLIANCE
The core compliance statement for all LLC nodes.
1.3.6.1.4.1.9.10.8.3.1.1current
llcCorePortGroup
OBJECT-GROUP
The llcCorePortGroup defines objects which are common to the LLC Port of all compliant connections.
1.3.6.1.4.1.9.10.8.3.2.1current
llcCoreSapGroup
OBJECT-GROUP
The llcCoreSapGroup defines objects which are common to the LLC SAP of all compliant connections.
1.3.6.1.4.1.9.10.8.3.2.2current
llcCoreCcGroup
OBJECT-GROUP
The llcCoreCcGroup defines objects which are common to the LLC CC of all compliant connections.
1.3.6.1.4.1.9.10.8.3.2.3current