MIBs Depot

CISCO-SIBU-STACKABLE-DUAL-SPEED-HUB-MIB

Registered at
1.3.6.1.4.1.9.10.44
Last updated
1998-10-23 00:00
Organization
Cisco Systems Inc.
Revisions
1998-10-23 00:00
Namespace
cisco
Source file
CISCO-SIBU-STACKABLE-DUAL-SPEED-HUB-MIB
Digest
sha256:e5c314a070205547007b9f6e8d1cd5d3f075721e4d54ed6f87188c5898a369eb

Description

The MIB module that extends the REPEATER-MIB to manage CISCO low end stackable repeater products. For the purpose of this mib, a hub is a repeater group and stack is collection of one or more hubs interconnected via stack bus connectors.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-sibu@cisco.com

Imports

FromSymbols
CISCO-SMIciscoExperiment
SNMP-REPEATER-MIBrptrGroupIndex, rptrPortGroupIndex, rptrPortIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-SIBU-STACKABLE-DUAL-SPEED-HUB-MIB
CISCO-SMI
IANAifType-MIB
IF-MIB
SNMP-REPEATER-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
HubNumber
TEXTUAL-CONVENTION
Represents the hub number that the system supports for stacking. The hub number represents the order in which a hub is stacked relative to other members of the stack. Lowest hub number represents the top member of the stack. This is also the number used in the command line interface.
current

Objects

NameOIDSyntaxAccessStatus
ciscoSibuStackableDualSpeedHubMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.1
cssSystem
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.1.1
cssSystemLinkTraps
OBJECT-TYPE
Indicates whether the stack is permitted to generate linkUp/linkDown traps for both repeater port and switch module's port. The stack provides only a single global control of link traps in contrast to per interface control provided by IF-MIB. The value of all instances ifLinkUpDownTrapEnable is set to TRUE (FALSE) if this object is set to enabled (disabled). The object ifLinkUpDownTrapEnable is read-only. A linkUp/linkDown trap is generated whenever a port's link STATUS or administrative status changes.
1.3.6.1.4.1.9.10.44.1.1.1INTEGER {enabled(1), disabled(2)}read-writecurrent
cssGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.1.2
cssGroupTable
OBJECT-TYPE
A list of member hubs in the stack.
1.3.6.1.4.1.9.10.44.1.2.1not-accessiblecurrent
cssGroupEntry
OBJECT-TYPE
Configuration parameters for an individual hub. An entry is created by default for the master unit in the stack. A entry is created (removed) when a hub is connected to (removed from) the stack.
1.3.6.1.4.1.9.10.44.1.2.1.1not-accessiblecurrent
cssGroupID
OBJECT-TYPE
The hub identifier of unit in a stack.
1.3.6.1.4.1.9.10.44.1.2.1.1.1HubNumberread-onlycurrent
cssGroupType
OBJECT-TYPE
The model type of the hub unit
1.3.6.1.4.1.9.10.44.1.2.1.1.2INTEGER {cisco1538MDS(1), cisco1538UDS(2), wsC412M(3), wsC412(4), wsC424M(5), wsC424(6)}read-onlycurrent
cssGroupSerialNo
OBJECT-TYPE
Serial number of the hardware.
1.3.6.1.4.1.9.10.44.1.2.1.1.4DisplayString (SIZE(0..20))read-onlycurrent
cssGroupBoardRevision
OBJECT-TYPE
Hardware version of the repeater board.
1.3.6.1.4.1.9.10.44.1.2.1.1.5Integer32 (0..2147483647)read-onlycurrent
cssGroupAgentBootVersion
OBJECT-TYPE
Returns the version number of the dual-speed hub BOOT software residing in flash. The format is 'V1.2.3'.
1.3.6.1.4.1.9.10.44.1.2.1.1.6DisplayString (SIZE(0..8))read-onlycurrent
cssGroupAgentFirmwareVersion
OBJECT-TYPE
Returns the version number of the dual-speed hub firmware residing in flash. The format is 'V1.2.3'.
1.3.6.1.4.1.9.10.44.1.2.1.1.7DisplayString (SIZE(0..8))read-onlycurrent
cssGroupAgentStatus
OBJECT-TYPE
Status of this hub agent. Each stack allows only one SNMP primary agent. notPresent(1): The hub does not have an agent. primary(2): The agent of this hub is a primary agent. backup(3) : The agent of this hub is a backup agent.
1.3.6.1.4.1.9.10.44.1.2.1.1.8INTEGER {notPresent(1), primary(2), backup(3)}read-onlycurrent
cssGroupAgentPhysAddress
OBJECT-TYPE
MAC address of this hub's agent
1.3.6.1.4.1.9.10.44.1.2.1.1.9PhysAddressread-onlycurrent
cssGroupInternalPowerState
OBJECT-TYPE
Indicates the state of the internal power supply. off : The internal power supply is off. on : The internal power supply is on.
1.3.6.1.4.1.9.10.44.1.2.1.1.12INTEGER {off(1), on(2)}read-onlycurrent
cssGroupRedundantPowerState
OBJECT-TYPE
Indicates the state of the external/backup power supply. off : the switch is not connected to a redundant power source. healthy : a redundant power source is connected to the switch and the power source is operating correctly. faulty : a redundant power source is connected to the switch but a failure exists in the power system.
1.3.6.1.4.1.9.10.44.1.2.1.1.13INTEGER {off(1), healthy(2), faulty(3)}read-onlycurrent
cssGroupReset
OBJECT-TYPE
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test). Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read.
1.3.6.1.4.1.9.10.44.1.2.1.1.14INTEGER {noReset(1), reset(2)}read-writecurrent
cssGroupConfigDefaultReset
OBJECT-TYPE
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test). All configuration parameters will revert to their factory default settings. Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read.
1.3.6.1.4.1.9.10.44.1.2.1.1.15INTEGER {noReset(1), reset(2)}read-writecurrent
cssGroupIsolatedState
OBJECT-TYPE
Setting this object to isolated(1) causes this hub to be isolated from the back plane bus. Setting this object to attached(2) causes this hub to be attached to the back plane bus.
1.3.6.1.4.1.9.10.44.1.2.1.1.16INTEGER {isolated(1), attached(2)}read-writecurrent
cssRepeaterPort
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.1.3
cssRepeaterPortTable
OBJECT-TYPE
The list of repeater port configurations on each hub unit.
1.3.6.1.4.1.9.10.44.1.3.1not-accessiblecurrent
cssRepeaterPortEntry
OBJECT-TYPE
Configuration parameters for an individual repeater port on a hub. The value of rptrPortIndex also indicates the physical port number of the port in the hub. An entry is created for each repeater port in a hub when the hub is connected to the stack. The corresponding entries are removed when the hub is removed from the stack.
1.3.6.1.4.1.9.10.44.1.3.1.1not-accessiblecurrent
cssRepeaterPortName
OBJECT-TYPE
A descriptive string of up to 20 characters used by the network administrator to name a port.
1.3.6.1.4.1.9.10.44.1.3.1.1.1DisplayString (SIZE(0..20))read-writecurrent
cssRepeaterPortControllerRevision
OBJECT-TYPE
Returns the revision number of the port controller.
1.3.6.1.4.1.9.10.44.1.3.1.1.2Integer32 (0..2147483647)read-onlycurrent
cssRepeaterPortSpeedAdmin
OBJECT-TYPE
Set to tenMbps(1) to operate in 10Mbps speed mode. Set to oneHundredMbps(2) to operate in 100Mbps speed mode. Set to autoNegotiate(3) to allow the switch to negotiate with the other end of the connection. The actual operating speed of the port is given by cssRepeaterPortSpeedStatus.
1.3.6.1.4.1.9.10.44.1.3.1.1.3INTEGER {tenMbps(1), oneHundredMbps(2), autoNegotiate(3)}read-writecurrent
cssRepeaterPortSpeedStatus
OBJECT-TYPE
The operating speed of the port.
1.3.6.1.4.1.9.10.44.1.3.1.1.4INTEGER {tenMbps(1), oneHundredMbps(2)}read-writecurrent
cssRepeaterPortLinkStatus
OBJECT-TYPE
The current port link status.
1.3.6.1.4.1.9.10.44.1.3.1.1.5INTEGER {link(1), noLink(2)}read-onlycurrent
cssSwitchPort
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.1.4
cssSwitchPortTable
OBJECT-TYPE
A list of switched ports on extension module on a each hub unit in the stack.
1.3.6.1.4.1.9.10.44.1.4.1not-accessiblecurrent
cssSwitchPortEntry
OBJECT-TYPE
Configuration parameters for an individual switch module port. An entry is created for each switch port on a module is inserted into a hub in the stack. The corresponding entries are removed when the module is removed from the hub in the stack, or if the hub is removed from the stack.
1.3.6.1.4.1.9.10.44.1.4.1.1not-accessiblecurrent
cssSwitchPortModuleID
OBJECT-TYPE
Unique ID number of a module unit in a hub as used in the command line interface.
1.3.6.1.4.1.9.10.44.1.4.1.1.1Integer32 (1..2147483647)read-onlycurrent
cssSwitchPortPortID
OBJECT-TYPE
The unique ID identifying a port on an extension module on a hub as used in the command line interface.
1.3.6.1.4.1.9.10.44.1.4.1.1.2Integer32 (1..2147483647)read-onlycurrent
cssSwitchPortName
OBJECT-TYPE
A descriptive string of up to 20 characters used by the network administrator to name a switch port.
1.3.6.1.4.1.9.10.44.1.4.1.1.3DisplayString (SIZE(0..20))read-writecurrent
cssSwitchPortType
OBJECT-TYPE
Type of switch module in this hub.
1.3.6.1.4.1.9.10.44.1.4.1.1.4INTEGER {wsX4001(1), wsX4002(2)}read-onlycurrent
cssSwitchPortControllerRevision
OBJECT-TYPE
The revision number of the port controller.
1.3.6.1.4.1.9.10.44.1.4.1.1.5Integer32 (0..2147483647)read-onlycurrent
cssSwitchPortState
OBJECT-TYPE
Setting this object to enabled(1) enables the port. Setting this object to disabled(2) disables the port.
1.3.6.1.4.1.9.10.44.1.4.1.1.6INTEGER {enabled(1), disabled(2)}read-writecurrent
cssSwitchPortDuplexAdmin
OBJECT-TYPE
Set to fullDuplex(1) to operate in full duplex mode: port will allow simultaneous transmit and receive which can double its bandwidth. Set to halfDuplex(2) to operate in normal mode. Set to autoNegotiate(3) to allow the switch to negotiate the duplex status with the other end of the connection.
1.3.6.1.4.1.9.10.44.1.4.1.1.7INTEGER {fullDuplex(1), halfDuplex(2), autoNegotiate(3)}read-writecurrent
cssSwitchPortDuplexStatus
OBJECT-TYPE
The operating duplex mode of the switched port.
1.3.6.1.4.1.9.10.44.1.4.1.1.8INTEGER {fullDuplex(1), halfDuplex(2)}read-onlycurrent
cssSwitchPortSpeedAdmin
OBJECT-TYPE
Set to tenMbps(1) to operate in 10Mbps speed mode. Set to oneHundredMbps(2) to operate in 100Mbps speed mode. Set to autoNegotiate(3) to allow the switch to negotiate the operating speed with the other end of the connection. If the value of object cssSwitchPortType is WS-X4002(2), this object will be read-only, because FX module only supports 100Mbps speed.
1.3.6.1.4.1.9.10.44.1.4.1.1.9INTEGER {tenMbps(1), oneHundredMbps(2), autoNegotiate(3)}read-writecurrent
cssSwitchPortSpeedStatus
OBJECT-TYPE
The operating speed of the switched port.
1.3.6.1.4.1.9.10.44.1.4.1.1.10INTEGER {tenMbps(1), oneHundredMbps(2)}read-onlycurrent
cssSwitchPortLinkStatus
OBJECT-TYPE
Indicates the link STATUS of switch port.
1.3.6.1.4.1.9.10.44.1.4.1.1.11INTEGER {link(1), noLink(2)}read-onlycurrent
ciscoSibuStackableDualSpeedHubNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.2
ciscoSibuStackableDualSpeedHubNotificationsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.2.0
ciscoSibuStackableDualSpeedHubMIBComformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.3
ciscoSibuStackableDualSpeedHubMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.3.1
ciscoSibuStackableDualSpeedHubMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.44.3.2

Notifications

NameOIDStatus
ciscoSibuStackableDualSpeedHubRptrPortLinkChange
NOTIFICATION-TYPE
This trap is generated whenever the value of cssRepeaterPortLinkStatus changes for a repeater port.
1.3.6.1.4.1.9.10.44.2.0.1current
ciscoSibuStackableDualSpeedHubSwitchPortLinkChange
NOTIFICATION-TYPE
This trap is generated whenever the value of cssSwitchPortLinkStatus changes for a switch port on an extension module.
1.3.6.1.4.1.9.10.44.2.0.2current

Conformance

NameOIDStatus
ciscoSibuStackableDualSpeedHubCompliance
MODULE-COMPLIANCE
The compliance statement for the Cisco Stackable Dual-Speed Hub products.
1.3.6.1.4.1.9.10.44.3.1.1current
ciscoSibuStackableDualSpeedHubGroup
OBJECT-GROUP
A collection of group objects for use with the Cisco Stackable Dual-Speed Hub products.
1.3.6.1.4.1.9.10.44.3.2.1current
ciscoSibuStackableDualSpeedHubRepeaterPortGroup
OBJECT-GROUP
A collection of repeater port objects for use with the Cisco Stackable Dual-Speed Hub products.
1.3.6.1.4.1.9.10.44.3.2.2current
ciscoSibuStackableDualSpeedHubSwitchPortGroup
OBJECT-GROUP
A collection of switch module port objects for use with the Cisco Stackable Dual-Speed Hub products.
1.3.6.1.4.1.9.10.44.3.2.3current