MIBs Depot

CISCO-OPTICAL-MONITORING-MIB

Registered at
1.3.6.1.4.1.9.10.83
Last updated
2001-12-04 11:30
Organization
Cisco Systems, Inc.
Revisions
2001-12-04 11:30
Namespace
cisco
Source file
CISCO-OPTICAL-MONITORING-MIB
Digest
sha256:4a8bc6f2d988b9240f09e175e5cb8e8ceb78e521bab8ff52963f96838c342361

Description

This MIB module is used to monitor optical parameters of a network element.This MIB deals with the operating parameters of the optical layer. The optical layer is a term that defines all the devices/systems that deal with the conversion of data in it's electrical form to optical form, transmission of the optical data, reception, and finally re-conversion to electrical signals.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 Tel: +1 800 553-NETS E-mail: gsr-netman@cisco.com

Imports

FromSymbols
CISCO-SMIciscoExperiment
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-OPTICAL-MONITORING-MIB
CISCO-SMI
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ciscoOpticalMonMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.1
comParameters
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.1.1
comParametersTable
OBJECT-TYPE
This table lists the instrumented parameters of all interfaces on the network element whose optical parameters are to be monitored.
1.3.6.1.4.1.9.10.83.1.1.1not-accessiblecurrent
comParametersEntry
OBJECT-TYPE
Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.
1.3.6.1.4.1.9.10.83.1.1.1.1not-accessiblecurrent
comTxBiasCurrent
OBJECT-TYPE
This holds the value of the laser diode forward bias current for the interface being instrumented, and is an indication of the Tx optical power.
1.3.6.1.4.1.9.10.83.1.1.1.1.1Integer32 (0..100000)read-onlycurrent
comTxPowerSupported
OBJECT-TYPE
Boolean to indicate if the interface being instrumented supports comTxPower. comTxPowerSupported is set to true if the interface supports the comTxPower object, and set to false otherwise.
1.3.6.1.4.1.9.10.83.1.1.1.1.2TruthValueread-onlycurrent
comTxPower
OBJECT-TYPE
This object holds the value of the transmitter optical power for the interface being instrumented. The optical is proportional to the laser diode current. This object makes sense only if comTxPowerSupported is true. All values must be converted to microWatts.
1.3.6.1.4.1.9.10.83.1.1.1.1.3Integer32 (0..2147483647)read-onlycurrent
comTxLaserTempSupported
OBJECT-TYPE
Boolean to indicate if the interface being instrumented supports comTxLaserTemp. comTxLaserTempSupported is set to true if the interface supports the comTxLaserTemp object, and set to false otherwise.
1.3.6.1.4.1.9.10.83.1.1.1.1.4TruthValueread-onlycurrent
comTxLaserTemp
OBJECT-TYPE
This object holds the value of the transmitter laser diode temperature for the interface being instrumented. This object indicates the health of the transmitter.
1.3.6.1.4.1.9.10.83.1.1.1.1.5Integer32 (-253..200)read-onlycurrent
comRxPowerACDC
OBJECT-TYPE
This object holds the value of the total power (AC + DC) at the optical Rx of the interface. All values must be converted to microWatts.
1.3.6.1.4.1.9.10.83.1.1.1.1.6Integer32 (0..2147483647)read-onlycurrent
comRxPowerACSupported
OBJECT-TYPE
Boolean to indicate if comRxPowerAC is supported by the interface being instrumented. comRxPowerACSupported is set to true if the interface supports the comRxPowerAC object,and set to false otherwise.
1.3.6.1.4.1.9.10.83.1.1.1.1.7TruthValueread-onlycurrent
comRxPowerAC
OBJECT-TYPE
This object holds the value of the AC power at the optical Receiver of the interface. Not all interfaces support this object.This object makes sense only if comRxPowerACSupported is true. All values must be converted to microWatts.
1.3.6.1.4.1.9.10.83.1.1.1.1.8Integer32 (0..2147483647)read-onlycurrent
ciscoOpticalMonMIBNotifPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.2
ciscoOpticalMonMIBNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.2.0
ciscoOpticalMonMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.3
ciscoOpticalMonMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.3.1
ciscoOpticalMonMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.83.3.2

Conformance

NameOIDStatus
ciscoOpticalMonMIBCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement the Cisco Optical Monitoring MIB.
1.3.6.1.4.1.9.10.83.3.1.1current
ciscoOpticalMonMIBParamGroup
OBJECT-GROUP
Parameters of the optical interfaces.
1.3.6.1.4.1.9.10.83.3.2.1current