Description

This MIB module is used for getting the ifIndex values given physical location and/or logical information. The physical information includes the slot, back-card and physical line, IMA group ID, MFR (Multilink Frame Relay) bundle etc. The logical information includes the logical interface or virtual interface number. In this MIB back card, bay, line module are used to refer to the back card.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com

Imports

FromSymbols
CISCOWAN-SMIciscoWan
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-MGX8800-IF-MAPPING-MIB
CISCOWAN-SMI
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
CmimIfType
TEXTUAL-CONVENTION
The interface types.
current

Objects

NameOIDSyntaxAccessStatus
cmimMappingObjects
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.7.1
cmimPhysToIf
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.7.1.1
cmimPhysToIfTable
OBJECT-TYPE
This table contains one or more rows, representing mappings of physical or logical interfaces to ifIndex values.
1.3.6.1.4.1.351.150.7.1.1.1not-accessiblecurrent
cmimPhysToIfEntry
OBJECT-TYPE
Information about a particular physical interface or logical interface.
1.3.6.1.4.1.351.150.7.1.1.1.1not-accessiblecurrent
cmimModuleIndex
OBJECT-TYPE
An index value that uniquely identifies the location of the module or a physical line. It has the information on slot number, back card and physical line number. Following is the mapping used for this object. Mapping used when cmimIfType is physicalLine(1), atm(3), adjCardApsLine(6), imaGrpAtmPhy(9) and mfrBundle(21) Bits 0-7 : Ignored Bits 8-15 : Back Card Number (0 - Ignored, 1-Top Back card 2 - Bottom Back card) Bits 16-23 : Logical slot number Bits 24-31 : Shelf number (1 - Currently, only value 1 is supported) Mapping used when cmimIfType is set to ds1Inds3(5), sonetVT(8), sonetPath(12), ds3SonetPath(13), atmSonetPath(14), atmDs3SonetPath(15), ds1VTPath(18), ds1Ds3SonetPath(19) and lapd(24) Bits 0-7 : DS3/E3/Sonet/Sdh physical line number Bits 8-15 : Back Card Number (0 - Ignored, 1-Top Back card 2 - Bottom Back card. Bits 16-23 : Logical slot number Bits 24-31 : Shelf number (1 - Currently, only value 1 is supported) Mapping used when cmimIfType is set to propAtm(7), frameRelayPort(16), ces(17), atmVciEndPt(20), ppplink(22) and pppMpbundle(23). Bits 0-7 : 0 Ignored Bits 8-15 : 0 Ignored Bits 16-23 : Logical slot number Bits 24-31 : Shelf number (1 - only value 1 is supported) Mapping used when cmimIfType is set to srmBertLine(10) or srmBertPort(11) Bits 0-7 : 0 Ignored Bits 8-15 : Logical slot number of NBSM Bits 16-23 : Logical slot number of SRM Bits 24-31 : Shelf number (1 - only value 1 is supported)
1.3.6.1.4.1.351.150.7.1.1.1.1.1Unsigned32not-accessiblecurrent
cmimIfNumber
OBJECT-TYPE
An index value uniquely identifies the interface number (physical, logical) of the module. The value specified depends on the value specified in cmimIfType. cmimIfType cmimIfNumber ---------- ------------ physicalLine(1) physical line number atm(3) physical line number for atm phy number ds1Inds3(5) DS1/E1 line number in a DS3/E3 adjCardApsLine(6) adjacent card APS line number propAtm(7) set to 1, this is the only value supported at this time sonetVT(8) DSxN tributary in a sonet/sdh line imaGrpAtmPhy(9) atm ima group for atm phy number srmBertLine(10) physical line number of NBSM srmBertPort(11) logical port number of NBSM. sonetPath(12) STS-1/AU-3 Path Number atmSonetPath(14) STS-1/AU-3 Path Number ds3SonetPath(13) Bits 0..15 : STS-1/AU-3 Path Number Bits 16..31: 1 for STS-1/AU-3 or DS3 Number within AU-4 atmDs3SonetPath(15) Bits 0..15 : STS-1/AU-3 Path Number Bits 16..31: 1 for STS-1/AU-3 or DS3 Number within AU-4 frameRelayPort(16) logical port number for frame interface ces(17) logical port number of circuit emulation service interface ds1InVT(18) Bits 0..7 : VT Number Bits 8..15: VT group number Bits 16..31: STS-1/AU-3 Path Number ds1Ds3SonetPath(19) Bits 0..7 : ds1 Number Bits 8..15: ds3 Number Bits 16..31: STS Path Number atmVciEndPt(20) Bits 0..15 : VCI Bits 16..27: VPI Bits 28..31: Port(ATM) mfrBundle(21) Multilink Frame Relay bundle number ppplink(22) ppp index of the ppp interface pppMpbundle(23) mpbundle index of the mpbundle interface lapd(24) Bits 0..7 : ds0 number Bits 8..15 : VT number or ds1 number Bits 16..23: VT group (DS3 ignore it) Bits 24..31: STS or DS3 path
1.3.6.1.4.1.351.150.7.1.1.1.1.2Unsigned32not-accessiblecurrent
cmimIfType
OBJECT-TYPE
The type of interface specified by cmimIfNumber.
1.3.6.1.4.1.351.150.7.1.1.1.1.3CmimIfTypenot-accessiblecurrent
cmimIfIndex
OBJECT-TYPE
The value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to the INDEXes specified in the table. Note that the values returned for cmimIfType=srmBertLine(10) and cmimIfType=srmBertPort(11) will not have any entries in the IF-TABLE.
1.3.6.1.4.1.351.150.7.1.1.1.1.4InterfaceIndexread-onlycurrent
cmimPhysToIfMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.7.3
cmimPhysToIfMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.7.3.1
cmimPhysToIfMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.351.150.7.3.2

Conformance

NameOIDStatus
cmimPhysToIfMIBCompliance
MODULE-COMPLIANCE
The compliance statement for cmimPhystoIfTable.
1.3.6.1.4.1.351.150.7.3.1.1current
cmimPhysToIfMIBGroup
OBJECT-GROUP
This group has to be implemented on all MGX8800 series products.
1.3.6.1.4.1.351.150.7.3.2.1current