CISCO-ENVMON-MIB
- Registered at
- 1.3.6.1.4.1.9.9.13
- Last updated
- 2003-12-01 00:00
- Organization
- Cisco Systems, Inc.
- Revisions
- 2003-12-01 00:00, 2003-11-25 00:00, 2002-10-15 00:00, 2002-07-17 00:00, 2002-02-04 00:00, 2001-08-30 00:00, 2001-08-16 00:00, 2001-05-07 00:00, 2000-01-31 00:00, 1998-10-22 00:00, 1998-08-05 00:00, 1996-11-12 00:00, 1995-08-15 00:00, 1995-03-13 00:00
- Namespace
- cisco
- Source file
CISCO-ENVMON-MIB- Digest
sha256:6ccf486e78ac57e364fdab307e8dac92ca4f585fd8776ab006110abe23831fa9
Description
The MIB module to describe the status of the Environmental Monitor on those devices which support one.
Contact
Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com
Imports
| From | Symbols |
|---|---|
| CISCO-SMI | ciscoMgmt |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CISCO-ENVMON-MIB CISCO-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| CiscoEnvMonState TEXTUAL-CONVENTION Represents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. | current | |||
| CiscoSignedGauge TEXTUAL-CONVENTION Represents the current value of an entity, as a signed integer. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ciscoEnvMonObjects OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.1 | |||
| ciscoEnvMonPresent OBJECT-TYPE The type of environmental monitor located in the chassis. An oldAgs environmental monitor card is identical to an ags environmental card except that it is not capable of supplying data, and hence no instance of the remaining objects in this MIB will be returned in response to an SNMP query. Note that only a firmware upgrade is required to convert an oldAgs into an ags card. | 1.3.6.1.4.1.9.9.13.1.1 | INTEGER {oldAgs(1), ags(2), c7000(3), ci(4), cAccessMon(6), cat6000(7), ubr7200(8), cat4000(9), c10000(10), osr7600(11), c7600(12), c37xx(13), other(14)} | read-only | current |
| ciscoEnvMonVoltageStatusTable OBJECT-TYPE The table of voltage status maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.2 | not-accessible | current | |
| ciscoEnvMonVoltageStatusEntry OBJECT-TYPE An entry in the voltage status table, representing the status of the associated testpoint maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.2.1 | not-accessible | current | |
| ciscoEnvMonVoltageStatusIndex OBJECT-TYPE Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning. | 1.3.6.1.4.1.9.9.13.1.2.1.1 | Integer32 (0..2147483647) | not-accessible | current |
| ciscoEnvMonVoltageStatusDescr OBJECT-TYPE Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. | 1.3.6.1.4.1.9.9.13.1.2.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| ciscoEnvMonVoltageStatusValue OBJECT-TYPE The current measurement of the testpoint being instrumented. | 1.3.6.1.4.1.9.9.13.1.2.1.3 | CiscoSignedGauge | read-only | current |
| ciscoEnvMonVoltageThresholdLow OBJECT-TYPE The lowest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated. | 1.3.6.1.4.1.9.9.13.1.2.1.4 | Integer32 | read-only | current |
| ciscoEnvMonVoltageThresholdHigh OBJECT-TYPE The highest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated. | 1.3.6.1.4.1.9.9.13.1.2.1.5 | Integer32 | read-only | current |
| ciscoEnvMonVoltageLastShutdown OBJECT-TYPE The value of the associated instance of the object ciscoEnvMonVoltageStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown. | 1.3.6.1.4.1.9.9.13.1.2.1.6 | Integer32 | read-only | current |
| ciscoEnvMonVoltageState OBJECT-TYPE The current state of the testpoint being instrumented. | 1.3.6.1.4.1.9.9.13.1.2.1.7 | CiscoEnvMonState | read-only | current |
| ciscoEnvMonTemperatureStatusTable OBJECT-TYPE The table of ambient temperature status maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.3 | not-accessible | current | |
| ciscoEnvMonTemperatureStatusEntry OBJECT-TYPE An entry in the ambient temperature status table, representing the status of the associated testpoint maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.3.1 | not-accessible | current | |
| ciscoEnvMonTemperatureStatusIndex OBJECT-TYPE Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning. | 1.3.6.1.4.1.9.9.13.1.3.1.1 | Integer32 (0..2147483647) | not-accessible | current |
| ciscoEnvMonTemperatureStatusDescr OBJECT-TYPE Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. | 1.3.6.1.4.1.9.9.13.1.3.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| ciscoEnvMonTemperatureStatusValue OBJECT-TYPE The current measurement of the testpoint being instrumented. | 1.3.6.1.4.1.9.9.13.1.3.1.3 | Gauge32 | read-only | current |
| ciscoEnvMonTemperatureThreshold OBJECT-TYPE The highest value that the associated instance of the object ciscoEnvMonTemperatureStatusValue may obtain before an emergency shutdown of the managed device is initiated. | 1.3.6.1.4.1.9.9.13.1.3.1.4 | Integer32 | read-only | current |
| ciscoEnvMonTemperatureLastShutdown OBJECT-TYPE The value of the associated instance of the object ciscoEnvMonTemperatureStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown. | 1.3.6.1.4.1.9.9.13.1.3.1.5 | Integer32 | read-only | current |
| ciscoEnvMonTemperatureState OBJECT-TYPE The current state of the testpoint being instrumented. | 1.3.6.1.4.1.9.9.13.1.3.1.6 | CiscoEnvMonState | read-only | current |
| ciscoEnvMonFanStatusTable OBJECT-TYPE The table of fan status maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.4 | not-accessible | current | |
| ciscoEnvMonFanStatusEntry OBJECT-TYPE An entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor. | 1.3.6.1.4.1.9.9.13.1.4.1 | not-accessible | current | |
| ciscoEnvMonFanStatusIndex OBJECT-TYPE Unique index for the fan being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning. | 1.3.6.1.4.1.9.9.13.1.4.1.1 | Integer32 (0..2147483647) | not-accessible | current |
| ciscoEnvMonFanStatusDescr OBJECT-TYPE Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. | 1.3.6.1.4.1.9.9.13.1.4.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| ciscoEnvMonFanState OBJECT-TYPE The current state of the fan being instrumented. | 1.3.6.1.4.1.9.9.13.1.4.1.3 | CiscoEnvMonState | read-only | current |
| ciscoEnvMonSupplyStatusTable OBJECT-TYPE The table of power supply status maintained by the environmental monitor card. | 1.3.6.1.4.1.9.9.13.1.5 | not-accessible | current | |
| ciscoEnvMonSupplyStatusEntry OBJECT-TYPE An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card. | 1.3.6.1.4.1.9.9.13.1.5.1 | not-accessible | current | |
| ciscoEnvMonSupplyStatusIndex OBJECT-TYPE Unique index for the power supply being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning. | 1.3.6.1.4.1.9.9.13.1.5.1.1 | Integer32 (0..2147483647) | not-accessible | current |
| ciscoEnvMonSupplyStatusDescr OBJECT-TYPE Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. | 1.3.6.1.4.1.9.9.13.1.5.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| ciscoEnvMonSupplyState OBJECT-TYPE The current state of the power supply being instrumented. | 1.3.6.1.4.1.9.9.13.1.5.1.3 | CiscoEnvMonState | read-only | current |
| ciscoEnvMonSupplySource OBJECT-TYPE The power supply source. unknown - Power supply source unknown ac - AC power supply dc - DC power supply externalPowerSupply - External power supply internalRedundant - Internal redundant power supply | 1.3.6.1.4.1.9.9.13.1.5.1.4 | INTEGER {unknown(1), ac(2), dc(3), externalPowerSupply(4), internalRedundant(5)} | read-only | current |
| ciscoEnvMonAlarmContacts OBJECT-TYPE Each bit is set to reflect the respective alarm being set. The bit will be cleared when the respective alarm is cleared. | 1.3.6.1.4.1.9.9.13.1.6 | Bits {minorVisual(0), majorVisual(1), criticalVisual(2), minorAudible(3), majorAudible(4), criticalAudible(5), input(6)} | read-only | current |
| ciscoEnvMonMIBNotificationEnables OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.2 | |||
| ciscoEnvMonEnableShutdownNotification OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonShutdownNotification. A false value will prevent shutdown notifications from being generated by this system. | 1.3.6.1.4.1.9.9.13.2.1 | TruthValue | read-write | current |
| ciscoEnvMonEnableVoltageNotification OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonVoltageNotification. A false value will prevent voltage notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif. | 1.3.6.1.4.1.9.9.13.2.2 | TruthValue | read-write | deprecated |
| ciscoEnvMonEnableTemperatureNotification OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonTemperatureNotification. A false value prevents temperature notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif. | 1.3.6.1.4.1.9.9.13.2.3 | TruthValue | read-write | deprecated |
| ciscoEnvMonEnableFanNotification OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonFanNotification. A false value prevents fan notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif. | 1.3.6.1.4.1.9.9.13.2.4 | TruthValue | read-write | deprecated |
| ciscoEnvMonEnableRedundantSupplyNotification OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonRedundantSupplyNotification. A false value prevents redundant supply notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif. | 1.3.6.1.4.1.9.9.13.2.5 | TruthValue | read-write | deprecated |
| ciscoEnvMonEnableStatChangeNotif OBJECT-TYPE This variable indicates whether the system produces the ciscoEnvMonVoltStatusChangeNotif, ciscoEnvMonTempStatusChangeNotif, ciscoEnvMonFanStatusChangeNotif and ciscoEnvMonSuppStatusChangeNotif. A false value will prevent these notifications from being generated by this system. | 1.3.6.1.4.1.9.9.13.2.6 | TruthValue | read-write | current |
| ciscoEnvMonMIBNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.3 | |||
| ciscoEnvMonMIBNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.3.0 | |||
| ciscoEnvMonMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.4 | |||
| ciscoEnvMonMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.4.1 | |||
| ciscoEnvMonMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.9.9.13.4.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| ciscoEnvMonShutdownNotification NOTIFICATION-TYPE A ciscoEnvMonShutdownNotification is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown. This notification contains no objects so that it may be encoded and sent in the shortest amount of time possible. Even so, management applications should not rely on receiving such a notification as it may not be sent before the shutdown completes. | 1.3.6.1.4.1.9.9.13.3.0.1 | current |
| ciscoEnvMonVoltageNotification NOTIFICATION-TYPE A ciscoEnvMonVoltageNotification is sent if the voltage measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonVoltStatusChangeNotif. | 1.3.6.1.4.1.9.9.13.3.0.2 | deprecated |
| ciscoEnvMonTemperatureNotification NOTIFICATION-TYPE A ciscoEnvMonTemperatureNotification is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a Notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonTempStatusChangeNotif. | 1.3.6.1.4.1.9.9.13.3.0.3 | deprecated |
| ciscoEnvMonFanNotification NOTIFICATION-TYPE A ciscoEnvMonFanNotification is sent if any one of the fans in the fan array (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonFanStatusChangeNotif. | 1.3.6.1.4.1.9.9.13.3.0.4 | deprecated |
| ciscoEnvMonRedundantSupplyNotification NOTIFICATION-TYPE A ciscoEnvMonRedundantSupplyNotification is sent if the redundant power supply (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonSuppStatusChangeNotif. | 1.3.6.1.4.1.9.9.13.3.0.5 | deprecated |
| ciscoEnvMonVoltStatusChangeNotif NOTIFICATION-TYPE A ciscoEnvMonVoltStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonVoltageState. | 1.3.6.1.4.1.9.9.13.3.0.6 | current |
| ciscoEnvMonTempStatusChangeNotif NOTIFICATION-TYPE A ciscoEnvMonTempStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonTemperatureState. | 1.3.6.1.4.1.9.9.13.3.0.7 | current |
| ciscoEnvMonFanStatusChangeNotif NOTIFICATION-TYPE A ciscoEnvMonFanStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonFanState. | 1.3.6.1.4.1.9.9.13.3.0.8 | current |
| ciscoEnvMonSuppStatusChangeNotif NOTIFICATION-TYPE A ciscoEnvMonSupplyStatChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonSupplyState. | 1.3.6.1.4.1.9.9.13.3.0.9 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| ciscoEnvMonMIBCompliance MODULE-COMPLIANCE The compliance statement for entities which implement the Cisco Environmental Monitor MIB. This is deprecated and new compliance ciscoEnvMonMIBComplianceRev1 is added. | 1.3.6.1.4.1.9.9.13.4.1.1 | deprecated |
| ciscoEnvMonMIBComplianceRev1 MODULE-COMPLIANCE The compliance statement for entities which implement the Cisco Environmental Monitor MIB. | 1.3.6.1.4.1.9.9.13.4.1.2 | current |
| ciscoEnvMonMIBGroup OBJECT-GROUP A collection of objects providing environmental monitoring capability to a cisco chassis. This group is deprecated in favour of ciscoEnvMonMIBGroupRev. | 1.3.6.1.4.1.9.9.13.4.2.1 | deprecated |
| ciscoEnvMonMIBGroupRev OBJECT-GROUP A collection of objects providing environmental monitoring capability to a cisco chassis. | 1.3.6.1.4.1.9.9.13.4.2.2 | current |
| ciscoEnvMonEnableStatChangeGroup OBJECT-GROUP A collection of objects providing enabling/disabling of the status change notifications for environmental monitoring. | 1.3.6.1.4.1.9.9.13.4.2.3 | current |
| ciscoEnvMonMIBNotifGroup NOTIFICATION-GROUP A notification group providing shutdown notification for environmental monitoring. | 1.3.6.1.4.1.9.9.13.4.2.4 | current |
| ciscoEnvMonStatChangeNotifGroup NOTIFICATION-GROUP A collection of notifications providing the status change for environmental monitoring. | 1.3.6.1.4.1.9.9.13.4.2.5 | current |
| ciscoEnvMonMIBMiscNotifGroup NOTIFICATION-GROUP A collection of various notifications for the enviromental monitoring mib module. The notifications the group and the group are both in deprecated state. The notifications in the group were deprecated in favour of notifications in ciscoEnvMonStatChangeNotifGroup. | 1.3.6.1.4.1.9.9.13.4.2.6 | deprecated |