MIBs Depot

CISCO-DS3-MIB

Registered at
1.3.6.1.4.1.9.9.132
Last updated
2002-05-21 00:00
Organization
Cisco Systems, Inc.
Revisions
2002-05-21 00:00, 2001-08-31 00:00, 2000-10-10 00:00, 2000-02-28 00:00
Namespace
cisco
Source file
CISCO-DS3-MIB
Digest
sha256:36b309d37146cb4d4b381ab94367ec5b0d3c2758a7ca4a6e3ef695ae8e5dd41c

Description

The MIB module to describe DS3 line objects. This is an extension to the standard DS3 MIB(RFC 2496).

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com

Imports

FromSymbols
CISCO-SMIciscoMgmt
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-DS3-MIB
CISCO-SMI
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ciscoDs3MIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.1
cds3Config
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.1.1
cds3ConfigTable
OBJECT-TYPE
The DS3 Configuration table. The table has objects for configuring a T3/E3 line.
1.3.6.1.4.1.9.9.132.1.1.1not-accessiblecurrent
cds3ConfigEntry
OBJECT-TYPE
An entry in the table. There is an entry for each available T3/E3 line, with an ifType value of 'ds3'(30). By default, lines are disabled. 'ifAdmin' from ifTable must be used to up the line. The objects in this table can be modified only when the line is up.
1.3.6.1.4.1.9.9.132.1.1.1.1not-accessiblecurrent
cds3LineType
OBJECT-TYPE
This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The values, in sequence, describe: Following values are applicable to DS3 interfaces only. ds3cbitadm : Indicates C-BIT ADM mode ds3cbitplcp : Indicates C-BIT PLCP mode ds3m23adm : Indicates M23 ADM mode ds3m23plcp : Indicates M23 PLCP mode dsx3M23 : Refer ANSI T1.107-1988 [9] dsx3SYNTRAN : Refer ANSI T1.107-1988 [9] dsx3CbitParity : Refer ANSI T1.107-1988 [9] dsx3ClearChannel : Refer ANSI T1.107-1988 [9] ds3cbitfrmronly : Indicates C-BIT FRAMER-ONLY mode ds3m23frmronly : Indicates M23 FRAMER-ONLY mode Following values are applicable to E3 interfaces only. e3g832adm : Indicates G.832 ADM mode e3g751adm : Indicates G.751 ADM mode e3g751plcp : Indicates G.751 PLCP mode e3Framed : Refer CCITT G.751 [12] e3Plcp : Refer ETSI T/NA(91)19 [14] e3g832frmronly : Indicates G.832 FRAMER-ONLY mode e3g751frmronly : Indicates G.751 FRAMER-ONLY mode.
1.3.6.1.4.1.9.9.132.1.1.1.1.1INTEGER {ds3cbitadm(1), ds3cbitplcp(2), e3g832adm(3), e3g751adm(4), e3g751plcp(5), ds3m23adm(6), ds3m23plcp(7), other(8), dsx3M23(9), dsx3SYNTRAN(10), dsx3CbitParity(11), dsx3ClearChannel(12), e3Framed(13), e3Plcp(14), ds3cbitfrmronly(15), ds3m23frmronly(16), e3g832frmronly(17), e3g751frmronly(18)}read-writecurrent
cds3LineAIScBitsCheck
OBJECT-TYPE
When check(1) is set, then Alarm Indication Signal (AIS) is declared when '1010...'b is found and C-Bits are all zero. When ignore(2) is set, an AIS condition is declared when the '1010...'b is detected irrespective of the state of the C-Bits. Does not apply to the E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation.
1.3.6.1.4.1.9.9.132.1.1.1.1.2INTEGER {check(1), ignore(2), notApplicable(3)}read-writecurrent
cds3LineRcvFEACValidation
OBJECT-TYPE
This entry specifies the FEAC (Far End Alarm and Control) code validation criteria. If 'fEACCodes4Of5' is specified, then a valid FEAC code is declared if 4 of 5 codes match. When 'fEACCodes8Of10' is specified, then a valid FEAC code is declared when 8 of 10 codes match. If disable(3) is specified, then FEAC code generation and detection is disabled. Does not apply to the E3 interface.
1.3.6.1.4.1.9.9.132.1.1.1.1.3INTEGER {fEACCodes4Of5(1), fEACCodes8Of10(2), disable(3)}read-writecurrent
cds3LineOOFCriteria
OBJECT-TYPE
This entry specifies the out of frame(OOF) decision criteria. If 'bits3Of8' is specified then an OOF condition is declared if at least 3 of 8 framing bits are in error. When 'bits3Of16' is specified then OOF is declared if 3 of 16 framing bits are found to be in error. OOF is declared when errors are detected in the framing octets for four consecutive frames. This object does not apply to E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation.
1.3.6.1.4.1.9.9.132.1.1.1.1.4INTEGER {bits3Of8(1), bits3Of16(2), notApplicable(3)}read-writecurrent
cds3TraceToTransmit
OBJECT-TYPE
Transmitted G.832 Trail Trace string.
1.3.6.1.4.1.9.9.132.1.1.1.1.5DisplayString (SIZE(1..16))read-writecurrent
cds3TraceToExpect
OBJECT-TYPE
G.832 Trail Trace string that is expected to be received from the other end.
1.3.6.1.4.1.9.9.132.1.1.1.1.6DisplayString (SIZE(1..16))read-writecurrent
cds3TraceAlarm
OBJECT-TYPE
The value of this object is set to traceFailure(2) when DS3 line receives a trace does not match the 'cds3TraceToExpect'.
1.3.6.1.4.1.9.9.132.1.1.1.1.7INTEGER {noAlarm(1), traceFailure(2)}read-onlycurrent
cds3InternalEqualizer
OBJECT-TYPE
This variable indicates whether the internal equalizer is being used or bypassed. Set this value depending on the line equipment to which the receiver is attached. Possible values are : use(1) : Use the internal equalizer byPass(2) : bypass internal equalizer(use external equalizer). This option allows easy interfacing of the device into systems already utilizing the external equalizers.
1.3.6.1.4.1.9.9.132.1.1.1.1.8INTEGER {use(1), byPass(2)}read-writecurrent
cds3NearEndLineLoopbackStatus
OBJECT-TYPE
Indicates the loopback status of the near end DS1 on this DS3 when loopback request is indicated. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = no loop(loop down) 1 = loop(loop up) 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 28 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop up 1 = loop down
1.3.6.1.4.1.9.9.132.1.1.1.1.9Unsigned32 (0..2147483647)read-onlycurrent
cds3FarEndLineLoopbackStatus
OBJECT-TYPE
Indicates the loopback status of the far end DS3,DS1 when remote DS1 loopback request is initiated. The remote DS1 loopback is initiated by setting dsx3SendCode object to dsx3SendDS1LoopCode(5). For unchannelized DS3 applications DS1s are unassigned. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = line loopback activate 1 = line loopback deactivate 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 29 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop down 1 = loop up
1.3.6.1.4.1.9.9.132.1.1.1.1.10Unsigned32 (0..2147483647)read-onlycurrent
cds3Alarm
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.1.2
cds3AlarmConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.1.2.1
cds3AlarmConfigTable
OBJECT-TYPE
The DS3 interface alarm configuration table. This table contains the parameters associated with detecting and declaring alarms for the interface. The parameters include severity of alarm, alarm integration parameters and 15 minute and 24 hour thresholds.
1.3.6.1.4.1.9.9.132.1.2.1.1not-accessiblecurrent
cds3AlarmConfigEntry
OBJECT-TYPE
An entry in the T3/E3 Alarm Configuration Table. The entries are automatically created for an ifType value of 'ds3'(30), with default values for objects. Thresholds may be configured for: Line Code Violations(LCV), LineErrored Seconds(LES), Line Severely Errored Seconds(LSES), P-bit Coding Violations(PCV), P-bit Errored Seconds(PES), P-bit Severely Errored Seconds(PSES), Severely Errored Seconds(SES), Severely Errored Framing Seconds(SEFS), Unavailable Seconds(UAS), C-bit coding violations(CCV), C-bit errored seconds(CES), C-bit errored seconds(CSES). Once these thresholds are exceeded, minor or major alarms are raised. Please refer to RFC2496 for descriptions of these errors.
1.3.6.1.4.1.9.9.132.1.2.1.1.1not-accessiblecurrent
cds3NEAlarmUpCount
OBJECT-TYPE
This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.1Unsigned32 (0..2147483647)read-writecurrent
cds3NEAlarmDownCount
OBJECT-TYPE
This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value is 1 and the integration counter is decremented by this value every 10 ms while no alarm persists. The counter is incremented by the value of cds3NEAlarmUpCount while there is no alarm (the counter does not decrement below zero). When the integration counter reaches zero any Alarm previously declared is removed.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.2Unsigned32 (0..2147483647)read-writecurrent
cds3NEAlarmThreshold
OBJECT-TYPE
The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be declared. If the up count is 6, and the threshold 150, an Alarm is integrated in 2.5 seconds. If the down count is 1, then alarm will be cleared in 15 seconds.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.3Unsigned32 (0..2147483647)read-writecurrent
cds3FEAlarmUpCount
OBJECT-TYPE
This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) and Alarm Indication Signal(AIS). The integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by this value while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds cds3FEAlarmThreshold an Alarm of the severity specified for the particular far end alarm is declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.4Unsigned32 (0..2147483647)read-writecurrent
cds3FEAlarmDownCount
OBJECT-TYPE
This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) and Remote Alarm Indication (RAI). The integration counter is decremented by this value every 10 ms (till zero), while no alarm persists. The counter is incremented by this value while there is no alarm. When the integration counter decrements to zero any previously declared Alarm is removed.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.5Unsigned32 (0..2147483647)read-writecurrent
cds3FEAlarmThreshold
OBJECT-TYPE
The value set in this object determines the value that the alarm integration counter must reach for an far end Alarm to be declared. If the up count is 6, the down count is 1 and the threshold 150, an Alarm is integrated in 2.5 sec and removed in 15 seconds.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.6Unsigned32 (0..2147483647)read-writecurrent
cds3StatisticalAlarmSeverity
OBJECT-TYPE
This variable is used to setup the severity of any of the Statistical alarms. So when a Statistical Counter exceeds its specified threshold the system will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.7INTEGER {minor(1), major(2), none(3)}read-writecurrent
cds3LCV15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.8Unsigned32 (0..2147483647)read-writecurrent
cds3LCV24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.9Unsigned32 (0..2147483647)read-writecurrent
cds3LES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.10Unsigned32 (0..2147483647)read-writecurrent
cds3LES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.11Unsigned32 (0..2147483647)read-writecurrent
cds3PCV15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.12Unsigned32 (0..2147483647)read-writecurrent
cds3PCV24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.13Unsigned32 (0..2147483647)read-writecurrent
cds3PES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.14Unsigned32 (0..2147483647)read-writecurrent
cds3PES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.15Unsigned32 (0..2147483647)read-writecurrent
cds3PSES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.16Unsigned32 (0..2147483647)read-writecurrent
cds3PSES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.17Unsigned32 (0..2147483647)read-writecurrent
cds3SEFS15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.18Unsigned32 (0..2147483647)read-writecurrent
cds3SEFS24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval
1.3.6.1.4.1.9.9.132.1.2.1.1.1.19Unsigned32 (0..2147483647)read-writecurrent
cds3UAS15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.20Unsigned32 (0..2147483647)read-writecurrent
cds3UAS24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval
1.3.6.1.4.1.9.9.132.1.2.1.1.1.21Unsigned32 (0..2147483647)read-writecurrent
cds3CCV15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.22Unsigned32 (0..2147483647)read-writecurrent
cds3CCV24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.23Unsigned32 (0..2147483647)read-writecurrent
cds3CES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.24Unsigned32 (0..2147483647)read-writecurrent
cds3CES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.25Unsigned32 (0..2147483647)read-writecurrent
cds3CSES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.26Unsigned32 (0..2147483647)read-writecurrent
cds3CSES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.27Unsigned32 (0..2147483647)read-writecurrent
cds3LSES15MinThreshold
OBJECT-TYPE
Used to set the 15 minute threshold for LSES(Line Severely Errored Seconds). The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.28Unsigned32 (0..2147483647)read-writecurrent
cds3LSES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.1.1.29Unsigned32 (0..2147483647)read-writecurrent
cds3LineStatisticalAlarmState
OBJECT-TYPE
This is a bitmap of the DS3 Line Statistical alarms. It is represented as a sum where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. Zero indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 PES current 15 minute threshold exceeded 2 PES 24 hour threshold exceeded 3 PSES current 15 minute threshold exceeded 4 PSES 24 hour threshold exceeded 5 SEFS current 15 minute threshold exceeded 6 SEFS 24 hour threshold exceeded 7 UAS current 15 minute threshold exceeded 8 UAS 24 hour threshold exceeded 9 LCV current 15 minute threshold exceeded 10 LCV 24 hour threshold exceeded 11 PCV current 15 minute threshold exceeded 12 PCV 24 hour threshold exceeded 13 LES current 15 minute threshold exceeded 14 LES 24 hour threshold exceeded 15 CCV current 15 minute threshold exceeded 16 CCV 24 hour threshold exceeded 17 CES current 15 minute threshold exceeded 18 CES 24 hour threshold exceeded 19 CSES current 15 minute threshold exceeded 20 CSES 24 hour threshold exceeded 21 LSES current 15 minute threshold exceeded 22 LSES 24 hour threshold exceeded
1.3.6.1.4.1.9.9.132.1.2.1.1.1.30Unsigned32 (0..2147483647)read-onlycurrent
cds3AlarmConfigPlcpTable
OBJECT-TYPE
The ATM interface PLCP alarm configuration table. PLCP is a sublayer over the DS3 interface, that carries ATM cells.
1.3.6.1.4.1.9.9.132.1.2.1.2not-accessiblecurrent
cds3AlarmConfigPlcpEntry
OBJECT-TYPE
An entry in the DS3 PLCP Alarm Configuration table. The entries contain parameters to configure DS3 PLCP error statistics thresholds, so that an alarm is raised whenever any threshold is exceeded. The entries are automatically created for active DS3 interfaces with Plcp framing enabled, with default values for objects.
1.3.6.1.4.1.9.9.132.1.2.1.2.1not-accessiblecurrent
cds3PlcpStatisticalAlarmSeverity
OBJECT-TYPE
This variable sets up the severity of PLCP Statistical alarm. So when PLCP Statistical alarm is detected the module will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.1INTEGER {minor(1), major(2), none(3)}read-writecurrent
cds3PlcpBip8CV15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.2Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpBip8CV24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.3Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpBip8ES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.4Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpBip8ES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.5Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpBip8SES15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.6Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpBip8SES24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.7Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpSEFS15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.8Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpSEFS24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.9Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpUAS15MinThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.10Unsigned32 (0..2147483647)read-writecurrent
cds3PlcpUAS24HrThreshold
OBJECT-TYPE
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
1.3.6.1.4.1.9.9.132.1.2.1.2.1.11Unsigned32 (0..2147483647)read-writecurrent
cds3AlarmPlcpTable
OBJECT-TYPE
The Plcp interface alarm table. This table maintains the CV,ES,SES, SEFS and UAS for DS3 line with Plcp framing selected. Please refer to RFC2496 for description of these various error statistics.
1.3.6.1.4.1.9.9.132.1.2.2not-accessiblecurrent
cds3AlarmPlcpEntry
OBJECT-TYPE
An entry in the DS3 Plcp Alarm table. Bucket statistics(15 minute and 24 hour interval statistics) are gathered for each existing DS3 line with PLCP frame format selected. An entry is created automatically and is indexed by the DS3 line number.
1.3.6.1.4.1.9.9.132.1.2.2.1not-accessiblecurrent
cds3PlcpLineAlarmState
OBJECT-TYPE
This variable is a bitmap of the DS3 Line ALarms. It is represented as sum where value 2^(N-1) is added to the sum if alarm corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 1 Receiving RAI 2 Transmitting RAI 3 Receiving OOF 4 Near End Local Loopback in effect 5 Near End Remote Loopback in effect
1.3.6.1.4.1.9.9.132.1.2.2.1.1Unsigned32read-onlycurrent
cds3PlcpLineStatisticalAlarmState
OBJECT-TYPE
This variable is a bitmap of the DS3 Plcp Line Statictical Alarms. It is represented as a sum, where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 Bip8CV 15 minute threshold exceeded 2 Bip8CV 24 hour threshold exceeded 3 Bip8ES 15 minute threshold exceeded 4 Bip8ES 24 hour threshold exceeded 5 Bip8SES 15 minute threshold exceeded 6 Bip8SES 24 hour threshold exceeded 7 Plcp SEFS 15 minute threshold exceeded 8 Plcp SEFS 24 hour threshold exceeded 9 Plcp UAS 15 minute threshold exceeded 10 Plcp UAS 24 hour threshold exceeded
1.3.6.1.4.1.9.9.132.1.2.2.1.2Unsigned32read-onlycurrent
cds3PlcpBip8CVCurrent
OBJECT-TYPE
The number of BIP-8 code violations (CV) encountered by the line in the current 15 minute period.
1.3.6.1.4.1.9.9.132.1.2.2.1.3Counter32read-onlycurrent
cds3PlcpBip8CV24HrBucket
OBJECT-TYPE
The number of BIP-8 CVs encountered by the line in the last 24 hours.
1.3.6.1.4.1.9.9.132.1.2.2.1.4Counter32read-onlycurrent
cds3PlcpBip8ESCurrent
OBJECT-TYPE
The number of BIP-8 Errored Seconds(ES) encountered by the line in the current 15 minute period.
1.3.6.1.4.1.9.9.132.1.2.2.1.5Counter32read-onlycurrent
cds3PlcpBip8ES24HrBucket
OBJECT-TYPE
The number of BIP-8 ES encountered by the line in the last 24 hour.
1.3.6.1.4.1.9.9.132.1.2.2.1.6Counter32read-onlycurrent
cds3PlcpBip8SESCurrent
OBJECT-TYPE
The number of BIP-8 Severely Errored Seconds(ES) encountered by the line in the current 15 minute period.
1.3.6.1.4.1.9.9.132.1.2.2.1.7Counter32read-onlycurrent
cds3PlcpBip8SES24HrBucket
OBJECT-TYPE
The number of BIP-8 SES encountered by the line in the last 24 hour.
1.3.6.1.4.1.9.9.132.1.2.2.1.8Counter32read-onlycurrent
cds3PlcpSEFSCurrent
OBJECT-TYPE
The number of BIP-8 Severely Errored Framing Seconds(SEFS) encountered by the line in the current 15-minute period.
1.3.6.1.4.1.9.9.132.1.2.2.1.9Counter32read-onlycurrent
cds3PlcpSEFS24HrBucket
OBJECT-TYPE
The number of BIP-8 SEFS encountered by the line in the last 24 hour.
1.3.6.1.4.1.9.9.132.1.2.2.1.10Counter32read-onlycurrent
cds3PlcpUASCurrent
OBJECT-TYPE
The number of Unavailable Seconds(UAS) encountered by the line in the current 15-minute period.
1.3.6.1.4.1.9.9.132.1.2.2.1.11Counter32read-onlycurrent
cds3PlcpUAS24HrBucket
OBJECT-TYPE
The number of BIP-8 UAS encountered by the line in the last 24 hour.
1.3.6.1.4.1.9.9.132.1.2.2.1.12Counter32read-onlycurrent
cds3Stats
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.1.3
cds3StatsTable
OBJECT-TYPE
T3/E3 Statistics table. This table maintains the number of times the line encountered Loss of Signal(LOS), out of frame(LOF), Alarm Indication signals(AIS), Remote alarm indications(RAI), C-bit coding violations(CCV), Framing Errors(FE), from the time it is up. Line fails and goes down as a result of failures. When the line is brought back up again by the user the error statistics are cleared.
1.3.6.1.4.1.9.9.132.1.3.1not-accessiblecurrent
cds3StatsEntry
OBJECT-TYPE
An entry in the T3/E3 Statistics table. Statistics are gathered for each existing T3/E3 line. An entry is created automatically for each T3/E3 line that is activated.
1.3.6.1.4.1.9.9.132.1.3.1.1not-accessiblecurrent
cds3RcvLOSCount
OBJECT-TYPE
The number of times Loss of Signal was detected with or without integrating to LOS alarm.
1.3.6.1.4.1.9.9.132.1.3.1.1.1Counter32read-onlycurrent
cds3RcvOOFCount
OBJECT-TYPE
The number of times Out of Frame was detected with or without integrating to OOF alarm.
1.3.6.1.4.1.9.9.132.1.3.1.1.2Counter32read-onlycurrent
cds3RAICount
OBJECT-TYPE
The number of timesRemote Alarm Indication was detected with or without integrating to RAI alarm.
1.3.6.1.4.1.9.9.132.1.3.1.1.3Counter32read-onlycurrent
cds3CCVCount
OBJECT-TYPE
The counter associated with the number of C-Bit Coding Violations encountered by a T3/E3 interface.
1.3.6.1.4.1.9.9.132.1.3.1.1.4Counter32read-onlycurrent
cds3FECount
OBJECT-TYPE
The number of Framing Errors encountered by a T3/E3 interface.
1.3.6.1.4.1.9.9.132.1.3.1.1.5Counter32read-onlycurrent
cds3EXZSCount
OBJECT-TYPE
The number of Excessive Zeros(EXZ) by a T3/E3 interface. An EXZ is the occurrence of any string of zeros having length equal to or greater than 3 for B3ZS, or any string of zeros having length greater than 4 for HDB3.
1.3.6.1.4.1.9.9.132.1.3.1.1.6Counter32read-onlycurrent
cds3LCVCount
OBJECT-TYPE
The count of both BPVs(Bipolar Violations) and EXZs(Excessive Zeros) encountered by a T3/E3 interface.An EXZ increments the LCV by one regardless of the length of the zero string.
1.3.6.1.4.1.9.9.132.1.3.1.1.7Counter32read-onlycurrent
cds3PCVCount
OBJECT-TYPE
This is the count of P-bit Coding Violation(PCV) error event encountered by DS3 interface. For all DS3 applications, a coding violation error event is a P-bit Parity Error(PERR) event. The parity errors occur when the calculated parity in the information bits of the DS3 frame does not match up with an expected parity value.
1.3.6.1.4.1.9.9.132.1.3.1.1.8Counter32read-onlycurrent
cds3CPECount
OBJECT-TYPE
The number of C-bit parity errors(CPERR) on a DS3 interface. This value is calculated over noninformation bits in the DS3 frame.
1.3.6.1.4.1.9.9.132.1.3.1.1.9Counter32read-onlycurrent
cds3FEBECount
OBJECT-TYPE
The number of Far End Block Errors(FEBE) encountered by a T3/E3 interface.These include frame alignment errors, multiframe alignment errors, and C-bit parity errors. These errors are generated by the transmitter at the far end, and indicate that the transmitter,cabling or the upstream node is faulty.
1.3.6.1.4.1.9.9.132.1.3.1.1.10Counter32read-onlycurrent
cds3RcvAISCount
OBJECT-TYPE
The number of times Alarm Indication Signals(AIS) were detected. The AIS indicates that an upstream failure has been detected by the far end.
1.3.6.1.4.1.9.9.132.1.3.1.1.11Counter32read-onlycurrent
cds3PlcpStatsTable
OBJECT-TYPE
T3 Plcp Statistics table. This table maintains the errors encountered by the T3 line with Plcp frame format selected, from the time the line is up.Line fails and goes down as a result of failures. When the line is brought back up again by the user after eliminating the error conditions, the statistics are cleared.
1.3.6.1.4.1.9.9.132.1.3.2not-accessiblecurrent
cds3PlcpStatsEntry
OBJECT-TYPE
An entry in the T3 Plcp Stats table. Statistics are gathered for each existing T3 line with PLCP frame format selected. An entry is created automatically and is indexed by the T3 line number.
1.3.6.1.4.1.9.9.132.1.3.2.1not-accessiblecurrent
cds3PlcpRcvBip8Count
OBJECT-TYPE
The number of of BIP-8 errors encountered by the line.
1.3.6.1.4.1.9.9.132.1.3.2.1.1Counter32read-onlycurrent
cds3PlcpRcvOOFCount
OBJECT-TYPE
The number of times Out of Frame(OOF) was detected with or without integrating to OOF alarm.
1.3.6.1.4.1.9.9.132.1.3.2.1.2Counter32read-onlycurrent
cds3PlcpRcvRAICount
OBJECT-TYPE
The number of times Remote Alarm Indication(RAI) was detected with or without integrating to RAI alarm.
1.3.6.1.4.1.9.9.132.1.3.2.1.3Counter32read-onlycurrent
cds3PlcpFECount
OBJECT-TYPE
The number of Framing Errors detected.
1.3.6.1.4.1.9.9.132.1.3.2.1.4Counter32read-onlycurrent
cds3PlcpFESecCount
OBJECT-TYPE
The number of Framing Error errored seconds.
1.3.6.1.4.1.9.9.132.1.3.2.1.5Counter32read-onlycurrent
cds3PlcpSEFSecCount
OBJECT-TYPE
The number of Severely errored Framing error seconds.
1.3.6.1.4.1.9.9.132.1.3.2.1.6Counter32read-onlycurrent
cds3PlcpFEBECount
OBJECT-TYPE
The count of Far End Block Errors (FEBE) detected.
1.3.6.1.4.1.9.9.132.1.3.2.1.7Counter32read-onlycurrent
cds3PlcpFEBESecCount
OBJECT-TYPE
The number of FEBE errored seconds.
1.3.6.1.4.1.9.9.132.1.3.2.1.8Counter32read-onlycurrent
cds3PlcpSEFEBESecCount
OBJECT-TYPE
The number of Severely errored FEBE seconds.
1.3.6.1.4.1.9.9.132.1.3.2.1.9Counter32read-onlycurrent
cds3IntervalTable
OBJECT-TYPE
The DS3 interface interval table.
1.3.6.1.4.1.9.9.132.1.3.4not-accessiblecurrent
cds3IntervalEntry
OBJECT-TYPE
An entry in the T3/E3 current interval table.
1.3.6.1.4.1.9.9.132.1.3.4.1not-accessiblecurrent
cds3IntervalNumber
OBJECT-TYPE
A number between 0 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minute interval completed 23 hours and 45 minutes prior to interval number 1. Interval number 0 refers to the current 15 minute data.
1.3.6.1.4.1.9.9.132.1.3.4.1.1INTEGER (0..96)read-onlycurrent
cds3IntervalLSESs
OBJECT-TYPE
The number of LSESs encountered by the line in 15 minute interval.
1.3.6.1.4.1.9.9.132.1.3.4.1.2Counter32read-onlycurrent
cds3Current24HrTable
OBJECT-TYPE
The DS3 interface current 24 hour table. This table contains counters for current 24 hour interval. Threshold on this counters are configured through cds3AlarmConfigTable table. 24 hour interval is aligned to wall clock.
1.3.6.1.4.1.9.9.132.1.3.5not-accessiblecurrent
cds3Current24HrEntry
OBJECT-TYPE
An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of 'ds3'(30), when interface is made active.
1.3.6.1.4.1.9.9.132.1.3.5.1not-accessiblecurrent
cds3LCVCurrent24Hr
OBJECT-TYPE
The number of LCVs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.1Counter32read-onlycurrent
cds3LESCurrent24Hr
OBJECT-TYPE
The number LESs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.2Counter32read-onlycurrent
cds3PCVCurrent24Hr
OBJECT-TYPE
The number PCVs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.3Counter32read-onlycurrent
cds3PESCurrent24Hr
OBJECT-TYPE
The number of PESs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.4Counter32read-onlycurrent
cds3PSESCurrent24Hr
OBJECT-TYPE
The number of PSESs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.5Counter32read-onlycurrent
cds3SEFSCurrent24Hr
OBJECT-TYPE
The number of SEFSs encountered by the line since the start of the current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.6Counter32read-onlycurrent
cds3UASCurrent24Hr
OBJECT-TYPE
The number of UASs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.7Counter32read-onlycurrent
cds3CCVCurrent24Hr
OBJECT-TYPE
The number CCVs encounterd by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.8Counter32read-onlycurrent
cds3CESCurrent24Hr
OBJECT-TYPE
The number of CESs encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.9Counter32read-onlycurrent
cds3CSESCurrent24Hr
OBJECT-TYPE
The number of CSESs encountered by the line since th start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.10Counter32read-onlycurrent
cds3LSESCurrent24Hr
OBJECT-TYPE
The number of LSESs (Line severedly errored seconds) encountered by the line since the start of current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.5.1.11Counter32read-onlycurrent
cds3Previous24HrTable
OBJECT-TYPE
The DS3 interface previous 24 hour table. This table contains counters for previous 24 hour interval. Implementation of this table is optional.
1.3.6.1.4.1.9.9.132.1.3.6not-accessiblecurrent
cds3Previous24HrEntry
OBJECT-TYPE
An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of ds3(30), when interface is made active.
1.3.6.1.4.1.9.9.132.1.3.6.1not-accessiblecurrent
cds3LCVPrevious24Hr
OBJECT-TYPE
The number of LCVs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.1Counter32read-onlycurrent
cds3LESPrevious24Hr
OBJECT-TYPE
The number LESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.2Counter32read-onlycurrent
cds3PCVPrevious24Hr
OBJECT-TYPE
The number PCVs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.3Counter32read-onlycurrent
cds3PESPrevious24Hr
OBJECT-TYPE
The number of PESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.4Counter32read-onlycurrent
cds3PSESPrevious24Hr
OBJECT-TYPE
The number of PSESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.5Counter32read-onlycurrent
cds3SEFSPrevious24Hr
OBJECT-TYPE
The number of SEFSs encountered by the line in the start of the current 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.6Counter32read-onlycurrent
cds3UASPrevious24Hr
OBJECT-TYPE
The number of UASs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.7Counter32read-onlycurrent
cds3CCVPrevious24Hr
OBJECT-TYPE
The number CCVs encounterd by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.8Counter32read-onlycurrent
cds3CESPrevious24Hr
OBJECT-TYPE
The number of CESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.9Counter32read-onlycurrent
cds3CSESPrevious24Hr
OBJECT-TYPE
The number of CSESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.10Counter32read-onlycurrent
cds3LSESPrevious24Hr
OBJECT-TYPE
The number of LSESs encountered by the line in the previous 24 hour period.
1.3.6.1.4.1.9.9.132.1.3.6.1.11Counter32read-onlycurrent
ciscoDs3MIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.8
ciscoDs3MIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.8.1
ciscoDs3MIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.9.132.8.2

Conformance

NameOIDStatus
ciscoDs3MIBCompliance
MODULE-COMPLIANCE
The Compliance statement for ciscoDs3 management group.
1.3.6.1.4.1.9.9.132.8.1.1current
ciscoDs3ConfMIBGroup
OBJECT-GROUP
Collection of DS3/E3 line related configuration parameters.
1.3.6.1.4.1.9.9.132.8.2.1current
cds3StatsMIBGroup
OBJECT-GROUP
Collection of DS3/E3 line related real time counters.
1.3.6.1.4.1.9.9.132.8.2.2current
ciscoDs3AlarmMIBGroup
OBJECT-GROUP
Collection of DS3/E3 related interval counters and threshold parameters.
1.3.6.1.4.1.9.9.132.8.2.3current
ciscoPlcpCounterMIBGroup
OBJECT-GROUP
Collection of PLCP related real time counters.
1.3.6.1.4.1.9.9.132.8.2.4current
ciscoPlcpAlarmMIBGroup
OBJECT-GROUP
Collection of PLCP related interval counters and threshold parameters.
1.3.6.1.4.1.9.9.132.8.2.5current
ciscoDs3Previous24HrGroup
OBJECT-GROUP
A collection DS3/E3 related previous 24 hour counters.
1.3.6.1.4.1.9.9.132.8.2.6current