CISCO-DMN-DSG-DIAG-MIB
- Registered at
- 1.3.6.1.4.1.1429.2.2.5.18
- Last updated
- 2012-03-20 08:00
- Organization
- Cisco Systems, Inc.
- Revisions
- 2012-03-20 08:00, 2010-10-13 08:00, 2010-08-03 10:00, 2010-04-12 09:00, 2010-02-12 12:00, 2009-12-07 12:00
- Namespace
- cisco
- Source file
CISCO-DMN-DSG-DIAG-MIB- Digest
sha256:fa5b69040bac92120bcc710d235fba3cbcc885e922884f3af4362b89d50aff27
Description
Cisco Detailed Diagnostics MIB.
Contact
Cisco Systems, Inc. Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553 NETS E-mail: cs-ipsla@cisco.com
Imports
| From | Symbols |
|---|---|
| CISCO-DMN-DSG-ROOT-MIB | ciscoDSGUtilities |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
CISCO-DMN-DSG-DIAG-MIB CISCO-DMN-DSG-ROOT-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| powerOn OBJECT-IDENTITY | 1.3.6.1.4.1.1429.2.2.5.18.1 | |||
| powerOnCreationDate OBJECT-TYPE Build Date of Product. | 1.3.6.1.4.1.1429.2.2.5.18.1.1 | DisplayString (SIZE(0..30)) | read-only | current |
| powerOnDate OBJECT-TYPE Last Power-On Date. | 1.3.6.1.4.1.1429.2.2.5.18.1.2 | DisplayString (SIZE(0..30)) | read-only | current |
| powerOnTotalHours OBJECT-TYPE Total Hours Running.The range is from 0 to 4294967295 hrs in steps of 1 hr. | 1.3.6.1.4.1.1429.2.2.5.18.1.3 | DisplayString (SIZE(1..32)) | read-only | current |
| powerOnHrsSinceLastPowerOff OBJECT-TYPE Hours Since Last Power Reset.The range is from 0 to 4294967295 hrs in steps of 1 hr. | 1.3.6.1.4.1.1429.2.2.5.18.1.4 | DisplayString (SIZE(1..32)) | read-only | current |
| powerOnTotResetCount OBJECT-TYPE Total Reset Counter.The range is from 0 to 4294967295. | 1.3.6.1.4.1.1429.2.2.5.18.1.5 | DisplayString (SIZE(1..32)) | read-only | current |
| powerOnClrableResetCount OBJECT-TYPE User Clearable Reset Counter.The range is from 0 to 4294967295. | 1.3.6.1.4.1.1429.2.2.5.18.1.6 | DisplayString (SIZE(1..32)) | read-only | current |
| powerOnReasonLastReset OBJECT-TYPE Reason for the Last Reset. | 1.3.6.1.4.1.1429.2.2.5.18.1.7 | DisplayString (SIZE(0..127)) | read-only | current |
| powerOnClearResetCounter OBJECT-TYPE Set this object to yes(2) to clear Power On Reset counter. | 1.3.6.1.4.1.1429.2.2.5.18.1.8 | INTEGER {writeOnly(1), yes(2)} | read-write | current |
| powerOnFactoryResetCount OBJECT-TYPE Total Factory Resets. | 1.3.6.1.4.1.1429.2.2.5.18.1.9 | DisplayString (SIZE(1..32)) | read-only | current |
| powerOnCurrentDateTime OBJECT-TYPE Displays the Current date and time. | 1.3.6.1.4.1.1429.2.2.5.18.1.10 | DisplayString (SIZE(1..32)) | read-only | current |
| diagTable OBJECT-IDENTITY | 1.3.6.1.4.1.1429.2.2.5.18.2 | |||
| diagHealthMonitorTable OBJECT-TYPE Health Monitor Table. | 1.3.6.1.4.1.1429.2.2.5.18.2.1 | not-accessible | current | |
| diagHealthMonitorEntry OBJECT-TYPE Entry for Health Monitor table. | 1.3.6.1.4.1.1429.2.2.5.18.2.1.1 | not-accessible | current | |
| diagHealthMonitorIndex OBJECT-TYPE Health Monitor index. | 1.3.6.1.4.1.1429.2.2.5.18.2.1.1.1 | Integer32 (0..1000) | not-accessible | current |
| diagHealthMonitorName OBJECT-TYPE Health Monitor Item Name - Gives Board Current temperature if monitor index is CURTEMP Gives Board Maximum tempearture if monitor index is MAXTEMP Gives Board Average temperature if monitor index is AVGTEMP Gives Board Temperature at intake 1/intake 2 if monitor index is IN1VAL/INVAL2 Gives Board FPGA Vicinity if monitor index is FPGAVIC Gives Board FPGA Value if monitor index is FPGAVAL. | 1.3.6.1.4.1.1429.2.2.5.18.2.1.1.2 | DisplayString (SIZE(0..8)) | read-only | current |
| diagHealthMonitorValue OBJECT-TYPE Health monitor Item Value. | 1.3.6.1.4.1.1429.2.2.5.18.2.1.1.3 | DisplayString (SIZE(0..8)) | read-only | current |
| diagFanRPMTable OBJECT-TYPE Fan RPM Table. | 1.3.6.1.4.1.1429.2.2.5.18.2.2 | not-accessible | current | |
| diagFanRPMEntry OBJECT-TYPE Entry for Fan RPM table. | 1.3.6.1.4.1.1429.2.2.5.18.2.2.1 | not-accessible | current | |
| diagFanRPMIndex OBJECT-TYPE Fan RPM index. | 1.3.6.1.4.1.1429.2.2.5.18.2.2.1.1 | Integer32 (0..2147483647) | not-accessible | current |
| diagFanRPMName OBJECT-TYPE Fan RPM Item Name : Gives Fan 1 speed in rpm if Fan RPM index is FAN1 Gives Fan 2 speed in rpm if Fan RPM index is FAN2 Gives Fan 3 speed in rpm if Fan RPM index is FAN3 Gives Fan 4 speed in rpm if Fan RPM index is FAN4 Gives Fan 5 speed in rpm if Fan RPM index is FAN5 Gives Fan 6 speed in rpm if Fan RPM index is FAN6 Gives Fan 7 speed in rpm if Fan RPM index is FAN7. | 1.3.6.1.4.1.1429.2.2.5.18.2.2.1.2 | DisplayString (SIZE(0..8)) | read-only | current |
| diagFanRPMValue OBJECT-TYPE Health monitor Item Value. | 1.3.6.1.4.1.1429.2.2.5.18.2.2.1.3 | DisplayString (SIZE(0..8)) | read-only | current |
| diagECCReadingsTable OBJECT-TYPE ECC Readings Table. | 1.3.6.1.4.1.1429.2.2.5.18.2.3 | not-accessible | current | |
| diagECCReadingsEntry OBJECT-TYPE Entry for ECC Readings table. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1 | not-accessible | current | |
| diagECCReadingsIndex OBJECT-TYPE ECC Readings index. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1.1 | INTEGER (1..15) | read-only | current |
| diagECCReadingsLocat OBJECT-TYPE ECC Reading Location. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1.2 | DisplayString (SIZE(0..64)) | read-only | current |
| diagECCReadingsType OBJECT-TYPE ECC Reading Type. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1.3 | DisplayString (SIZE(0..64)) | read-only | current |
| diagECCReadingsVal OBJECT-TYPE ECC Reading Value. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1.4 | DisplayString (SIZE(0..64)) | read-only | current |
| diagECCReadingsApplicability OBJECT-TYPE ECC Reading Applicibility for this device. | 1.3.6.1.4.1.1429.2.2.5.18.2.3.1.5 | DisplayString (SIZE(0..64)) | read-only | current |
| diagCtrlHistoryTable OBJECT-TYPE Control History Table. | 1.3.6.1.4.1.1429.2.2.5.18.2.4 | not-accessible | current | |
| diagCtrlHistoryEntry OBJECT-TYPE Entry for Control History table. | 1.3.6.1.4.1.1429.2.2.5.18.2.4.1 | not-accessible | current | |
| diagCtrlHistoryIndex OBJECT-TYPE Control History Table Index. | 1.3.6.1.4.1.1429.2.2.5.18.2.4.1.1 | Counter32 | read-only | current |
| diagCtrlHistoryHistory OBJECT-TYPE Control History Text. | 1.3.6.1.4.1.1429.2.2.5.18.2.4.1.2 | DisplayString (SIZE(0..64)) | read-only | current |
| diagCtrlHistoryDateTime OBJECT-TYPE Control History Date and Time. | 1.3.6.1.4.1.1429.2.2.5.18.2.4.1.3 | DisplayString (SIZE(0..30)) | read-only | current |