MIBs Depot

CISCO-6400-CHASSIS-MIB

Registered at
1.3.6.1.4.1.9.10.27
Last updated
2001-10-22 00:00
Organization
Cisco Systems, Inc.
Revisions
2001-10-22 00:00, 2001-05-10 12:34, 2000-09-25 12:34, 1999-03-22 00:00, 1998-08-05 00:00, 1997-12-10 00:00
Namespace
cisco
Source file
CISCO-6400-CHASSIS-MIB
Digest
sha256:dc5025d618d4cd3bd2287364931c66b6cc7dabc4de72f501edb780e1c2767e4e

Description

Add nrpSwitchoverAlarm, nrpSecondaryFailureAlarm, nrpSecondaryRemovedAlarm, and nrpMismatchAlarm.

Contact

Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-atm@cisco.com

Imports

FromSymbols
CISCO-SMIciscoExperiment
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-6400-CHASSIS-MIB
CISCO-SMI
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
APSEventStatus
TEXTUAL-CONVENTION
APS event status of APS channel.
current

Objects

NameOIDSyntaxAccessStatus
cisco6400ChassisMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.1
c64RedundantGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.1.1
c64MainCPUConfigAutoSync
OBJECT-TYPE
This object is an OR bit mask indicating various auto-sync configuration: Bit 0, if set, indicates that standard syncable objects are set for auto-sync. The standard set of objects may evolve from software release to release. In release 1, this set is startup-config, bootvar and config-register. This flag is independent to the other flag settings described below. Bit 1, if set, indicates startup-config is set for auto-sync Bit 2. if set, indicates running-config is set for auto-sync. This flag is not supported in revison 1. Bit 3, if set, indicates bootvar is set for auto-sync Bit 4, if set, indicates config-register is set for auto-sync. Bit 5..31, are reserved for future expansion. Setting any bit in this range will have no effect.
1.3.6.1.4.1.9.10.27.1.1.1Integer32 (0..65535)read-writecurrent
c64MainCPUSwitchOver
OBJECT-TYPE
This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have: For a redundant NSP-A|B, force them to exchange the primary and secondary roles. The primary NSP will be reloaded.
1.3.6.1.4.1.9.10.27.1.1.2INTEGER {ok(1), forceOver(2)}read-writecurrent
c64SlotConfigTable
OBJECT-TYPE
A list of redundant slot-pair entries. A managment station that wish to create the redundancy entry other than NSP should perform the following steps: Get the ciscoLS1010ModuleIndex from ciscoLS1010ModuleTable which are mapped to the corresponding pair of the physical slots to be configured for redundancy. Use the pair of the ciscoLS1010ModuleIndex and a unique entry index to create table entry. Only the adjacent slots can be configured for redundancy.
1.3.6.1.4.1.9.10.27.1.1.3not-accessiblecurrent
c64SlotConfigEntry
OBJECT-TYPE
Entry containing information for a particular pair of redundant slots. The object value of c64Slot1Index & c64Slot2Index refer to the pair of ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable to be configured as redundant.
1.3.6.1.4.1.9.10.27.1.1.3.1not-accessiblecurrent
c64SlotConfigModule1Index
OBJECT-TYPE
This object specify the first slot in the pair of slots to be configured for the redundacy. Its value is obtained from ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable.
1.3.6.1.4.1.9.10.27.1.1.3.1.1INTEGER (1..15)not-accessiblecurrent
c64SlotConfigModule2Index
OBJECT-TYPE
This object specify the second slot in the pair of slots to be configured for the redundacy. Its value is the obtained from ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable.
1.3.6.1.4.1.9.10.27.1.1.3.1.2INTEGER (1..15)not-accessiblecurrent
c64Slot1Name
OBJECT-TYPE
Name of slot#1 in the pair of slots configured to redundant.
1.3.6.1.4.1.9.10.27.1.1.3.1.3DisplayStringread-onlycurrent
c64Slot2Name
OBJECT-TYPE
Name of slot#2 in the pair of slots configured to redundant.
1.3.6.1.4.1.9.10.27.1.1.3.1.4DisplayStringread-onlycurrent
c64SlotConfigPrefIndex
OBJECT-TYPE
This object specify which slot in the pair of redundancy to be used as prefer slot. The value of: primarySlot(1) is telling the system use the slot referred by c64Slot1Index as preferred slot. secondarySlot(2) is to use the slot referred by c64Slot2Index. The default is primarySlot(1). The slot prefer feature is removed and the the object is deprecated
1.3.6.1.4.1.9.10.27.1.1.3.1.5INTEGER {primarySlot(1), secondarySlot(2)}read-createdeprecated
c64SlotSwitchOver
OBJECT-TYPE
This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have: For a redundant NRP slot pair, force them to exchange the primary and secondary roles. For a redundant carrier slot pair, force both the subslots (line cards) to exchange the primary(working) and secondary(protection) roles.
1.3.6.1.4.1.9.10.27.1.1.3.1.6INTEGER {ok(1), forceOver(2)}read-createcurrent
c64SlotConfigStatus
OBJECT-TYPE
The status object for the c64SlotTable entry.
1.3.6.1.4.1.9.10.27.1.1.3.1.7RowStatusread-createcurrent
c64SubSlotConfigTable
OBJECT-TYPE
A list of redundant subslot pair entries. A managment station that wish to create the subslot redundancy entry should perform the following steps: Get the ciscoLS1010ModuleIndex & ciscoLS1010SubModuleIndex from ciscoLS1010SubModuleTable which are mapped to the corresponding pair of the physical sub-slots to be configured for the redundancy. Use the pair of the ciscoLS1010ModuleIndex & ciscoLS1010SubModuleIndex and an unique entry index to create table entry. Only the adjacent sub-slots can be configured for redundancy.
1.3.6.1.4.1.9.10.27.1.1.5not-accessiblecurrent
c64SubSlotConfigEntry
OBJECT-TYPE
Entry containing information for a particular pair of redundant subslots.
1.3.6.1.4.1.9.10.27.1.1.5.1not-accessiblecurrent
c64SubSlotRedundantIndex
OBJECT-TYPE
An arbitrary integer-value to uniquely identify a redundant slot pair. This value must remain constant while the NSP is running. It is not guarenteed to be constant between reboots or switchover of the NSP.
1.3.6.1.4.1.9.10.27.1.1.5.1.1INTEGER (1..65535)not-accessiblecurrent
c64SubSlotConfigModule1Index
OBJECT-TYPE
This object specify the first slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010SubModuleTable.
1.3.6.1.4.1.9.10.27.1.1.5.1.2INTEGER (1..15)not-accessiblecurrent
c64SubSlotConfigSubModule1Index
OBJECT-TYPE
This object specify the first sub-slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010SubModuleTable.
1.3.6.1.4.1.9.10.27.1.1.5.1.3INTEGER (0..1)not-accessiblecurrent
c64SubSlotConfigModule2Index
OBJECT-TYPE
This object specify the second slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010SubModuleTable.
1.3.6.1.4.1.9.10.27.1.1.5.1.4INTEGER (1..15)not-accessiblecurrent
c64SubSlotConfigSubModule2Index
OBJECT-TYPE
This object specify the second sub-slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010SubModuleTable.
1.3.6.1.4.1.9.10.27.1.1.5.1.5INTEGER (0..1)not-accessiblecurrent
c64SubSlot1Name
OBJECT-TYPE
This object is to reflect the string name in the format of #/# for the sub-slot1 in the pair of redundancy. This is produced by agent when the table entry is created.
1.3.6.1.4.1.9.10.27.1.1.5.1.6DisplayStringread-onlycurrent
c64SubSlot2Name
OBJECT-TYPE
This object is to reflect the string name in the format of #/# for the sub-slot2 in the pair of redundancy. This is produced by agent when table entry is created.
1.3.6.1.4.1.9.10.27.1.1.5.1.7DisplayStringread-onlycurrent
c64SubSlotConfigPrefIndex
OBJECT-TYPE
This object specify which sub-slot in the pair of redundancy to be used as prefer sub-slot. The value of: primarySubslot(1) is telling the system use the subslot referred by c64SubSlotConfigModule1Index and c64SubSlotConfigSubModule1Index as preferred sub-slot. secondarySubslot(2) is to use the sub-slot referred by c64SubSlotConfigModule2Index and c64SubSlotConfigSubModule2Index. The default is primarySubslot(1). The subslot prefer feature is removed and the object is deprecated
1.3.6.1.4.1.9.10.27.1.1.5.1.8INTEGER {primarySubslot(1), secondarySubslot(2)}read-createdeprecated
c64SubSlotSwitchOver
OBJECT-TYPE
This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have the result of: For a redundant subslot card pair, force the current master and slave cards (for NRPs) or working and protection cards (for linecards) to exchange roles.
1.3.6.1.4.1.9.10.27.1.1.5.1.9INTEGER {ok(1), forceOver(2)}read-createcurrent
c64SubSlotConfigStatus
OBJECT-TYPE
The status object for c64SubSlotConfigTable entry.
1.3.6.1.4.1.9.10.27.1.1.5.1.10RowStatusread-createcurrent
c64PortConfigTable
OBJECT-TYPE
A list of redundant port-pair entries. A management station that wish to create the redundant entry should perform the following steps: Get the ciscoLS1010ModuleIndex, ciscoLS1010SubModuleIndex and ciscoLS1010PortIndex from ciscoLS1010PortTable which are mapped to the corresponding pair of the physical ports to be configured for the redundancy. Lookup the c64SubSlotConfigTable to see if the corresponding sub-slots has been configured for redundancy. If yes, get the entry's c64SubSlotRedundantIndex. Otherwise the application should abort this port redundancy configuration. Use the c64SubSlotRedundantIndex value and ciscoLS1010ModuleIndex, ciscoLS1010SubModuleIndex and ciscoLS1010PortIndex to create table entry. Only the adjacent ports in the adjacent sub-slots can be configured for redundancy.
1.3.6.1.4.1.9.10.27.1.1.6not-accessiblecurrent
c64PortConfigEntry
OBJECT-TYPE
Entry containing information for a particual pair of redundant ports.
1.3.6.1.4.1.9.10.27.1.1.6.1not-accessiblecurrent
c64PortConfigModule1Index
OBJECT-TYPE
This object specify the first slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.1INTEGER (1..15)not-accessiblecurrent
c64PortConfigSubModule1Index
OBJECT-TYPE
This object specify the first sub-slot which contain the port to be configured as the redundancy pair. Its value is obtained from ciscoLS1010SubModuleIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.2INTEGER (0..1)not-accessiblecurrent
c64PortConfigPort1Index
OBJECT-TYPE
This object specify the first port in the pair of ports to be configured for the redundancy. Its value is obtained from ciscoLS1010PortIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.3INTEGER (0..255)not-accessiblecurrent
c64PortConfigModule2Index
OBJECT-TYPE
This object specify the second slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.4INTEGER (1..15)not-accessiblecurrent
c64PortConfigSubModule2Index
OBJECT-TYPE
This object specify the second sub-slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.5INTEGER (0..1)not-accessiblecurrent
c64PortConfigPort2Index
OBJECT-TYPE
This object specify the second port in the pair of ports to be configured for the redundancy. Its value is obtained from the ciscoLS1010PortIndex in ciscoLS1010PortTable.
1.3.6.1.4.1.9.10.27.1.1.6.1.6INTEGER (0..255)not-accessiblecurrent
c64Port1Name
OBJECT-TYPE
This object is to reflect the string name in the format of #/#/# for the port1 in the pair of redundancy. This is produced by agent when the table entry is created.
1.3.6.1.4.1.9.10.27.1.1.6.1.7DisplayStringread-onlycurrent
c64Port2Name
OBJECT-TYPE
This object is to reflect the string name in the format of #/#/# for the port2 in the pair of redundancy. This is produced by agent when the table entry is created.
1.3.6.1.4.1.9.10.27.1.1.6.1.8DisplayStringread-onlycurrent
c64PortConfigPrefIndex
OBJECT-TYPE
This object specify which port in the pair of redundancy to be used as prefer port. The value of: primaryPort(1) is telling the system use the port referred by c64PortConfigModule1Index, c64PortConfigSubModule1Index and c64PortConfigPort1Index as preferred port. secondaryPort(2) is to use the port referred by c64PortConfigModule2Index, c64PortConfigSubModule2Index and c64PortConfigPort2Index. The default is primaryPort(1).
1.3.6.1.4.1.9.10.27.1.1.6.1.9INTEGER {primaryPort(1), secondaryPort(2)}read-createcurrent
c64PortSwitchOver
OBJECT-TYPE
This object, when read always return a value of ok(1). Setting this object to one of the acceptable values gives the following results: forceOver(2): Force the current working and protection ports to exchange roles.
1.3.6.1.4.1.9.10.27.1.1.6.1.10INTEGER {ok(1), forceOver(2)}read-createcurrent
c64PortConfigStatus
OBJECT-TYPE
The status object for c64PortConfigTable entry.
1.3.6.1.4.1.9.10.27.1.1.6.1.11RowStatusread-createcurrent
c64SonetAPSConfigTable
OBJECT-TYPE
A table containing all instances of Sonet APS configuration informations. To configure any APS objects in this table, the corresponding subslots pair have to be already configured for redundancy.
1.3.6.1.4.1.9.10.27.1.1.7not-accessiblecurrent
c64SonetAPSConfigEntry
OBJECT-TYPE
Entry containing APS information for a particular interface.
1.3.6.1.4.1.9.10.27.1.1.7.1not-accessiblecurrent
c64SonetAPSMode
OBJECT-TYPE
This object is used to set the APS mode on the corresponding interface referenced by ifIndex object. The value linear(1) is the APS mode of linear 1+1 nonreverting and unidirectional. This only true APS mode supported in cisco6400 at FCS. The value yCable(2) is providing the port hardware redundancy but not transmission line redundancy and is not strictly an APS mode.
1.3.6.1.4.1.9.10.27.1.1.7.1.1INTEGER {linear(1), yCable(2), disable(3)}read-createcurrent
c64SonetAPSBERThreshold
OBJECT-TYPE
This is object is used to set the Bit-Error-Rate threshold at which an APS request of priority 'Signal Degrade' will be posted. Value of 0 to disable the threshold.
1.3.6.1.4.1.9.10.27.1.1.7.1.2INTEGER (0..150000)read-createcurrent
c64SonetAPSSwitchCmd
OBJECT-TYPE
This object when set except clear(4) is used to post an APS priority request. This request succeeds if no higher-priority request is posted. lockOut(1): locks out the protection channel corresponding to this entry forceWorking(2) & manualWorking(4): post a request to switch away from the working channel to protection channel of this entry forceProtect(3) & manualProtect(5): post a request to switch away from the protection channel to working channel of this entry clear(6): Clears all posted APS priority requests in this channel.
1.3.6.1.4.1.9.10.27.1.1.7.1.3INTEGER {lockOut(1), forceWorking(2), forceProtect(3), manualWorking(4), manualProtect(5), clear(6)}read-createcurrent
c64SonetAPSSFBERThreshold
OBJECT-TYPE
This is object is used to set the Signal Fail Bit-Error-Rate threshold at which an APS request of priority 'Signal Fail' will be posted. 3 => 10E-3, 4 => 10E-4, 5 => 10E-5
1.3.6.1.4.1.9.10.27.1.1.7.1.4INTEGER (3..5)read-createcurrent
c64SonetAPSStatsTable
OBJECT-TYPE
A table containing APS statistics and alarms information for each interface.
1.3.6.1.4.1.9.10.27.1.1.8not-accessiblecurrent
c64SonetAPSStatsEntry
OBJECT-TYPE
A row in the c64SonetAPSStatsTable which corresponds to the statistics/alarms kept by a particular APS interface.
1.3.6.1.4.1.9.10.27.1.1.8.1not-accessiblecurrent
c64SonetAPSWorkSectionStatus
OBJECT-TYPE
This variable indicates the section level status of the working channel in APS. The c64SonetAPSWorkSectionStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetSectionNoDefect 2 sonetSectionLOS 3 sonetSectionLOF 4 sonetBIPE(BIp-8)
1.3.6.1.4.1.9.10.27.1.1.8.1.1Integer32 (1..65535)read-onlycurrent
c64SonetAPSWorkLineStatus
OBJECT-TYPE
This variable indicates the line level status of the working channel in APS. The c64SonetAPSWorkLineStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetLineNoDefect 2 sonetLineAIS 3 sonetLineRDI 4 sonetBIPE(BIP-8/24) 5 sonetFEBE
1.3.6.1.4.1.9.10.27.1.1.8.1.2Integer32 (1..65535)read-onlycurrent
c64SonetAPSWorkPathStatus
OBJECT-TYPE
This variable indicates the path level status of the working channel in APS. The c64SonetAPSWorkPathStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetPathNoDefect 2 sonetPathSTSAIS 3 sonetPathSTSRDI 4 sonetPathSTSLOP 5 sonetBIPE(BIP-8) 6 sonetFEBE 7 sonetPathUnequipped 8 sonetPathSignalLabelMismatch
1.3.6.1.4.1.9.10.27.1.1.8.1.3Integer32 (1..65535)read-onlycurrent
c64SonetAPSWorkSectionBIPE
OBJECT-TYPE
This object counts the number of section BIP-8 errors in working channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.4Counter32read-onlycurrent
c64SonetAPSWorkLineBIPE
OBJECT-TYPE
This object counts the number of line BIP-8/24 errors in working channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.5Counter32read-onlycurrent
c64SonetAPSWorkLineFEBE
OBJECT-TYPE
This object counts the number of line far-end-block-errors in working channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.6Counter32read-onlycurrent
c64SonetAPSWorkPathBIPE
OBJECT-TYPE
This object counts the number of path BIP-8 errors in working channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.7Counter32read-onlycurrent
c64SonetAPSWorkPathFEBE
OBJECT-TYPE
This object counts the number of path far-end-block-errors in working channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.8Counter32read-onlycurrent
c64SonetAPSWorkPortStatus
OBJECT-TYPE
This object indicates the last aps event detected in working port.
1.3.6.1.4.1.9.10.27.1.1.8.1.9APSEventStatusread-onlycurrent
c64SonetAPSProtectSectionStatus
OBJECT-TYPE
This variable indicates the section level status of the protection channel in APS. The c64SonetAPSProtectSectionStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetSectionNoDefect 2 sonetSectionLOS 4 sonetSectionLOF 8 sonetBIPE(BIp-8)
1.3.6.1.4.1.9.10.27.1.1.8.1.10Integer32 (1..65535)read-onlycurrent
c64SonetAPSProtectLineStatus
OBJECT-TYPE
This variable indicates the line level status of the protection channel in APS. The c64SonetAPSProtectLineStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetLineNoDefect 2 sonetLineAIS 4 sonetLineRDI 8 sonetBIPE(BIP-8/24) 16 sonetFEBE
1.3.6.1.4.1.9.10.27.1.1.8.1.11Integer32 (1..65535)read-onlycurrent
c64SonetAPSProtectPathStatus
OBJECT-TYPE
This variable indicates the path level status of the protection channel in APS. The c64SonetAPSProtectPathStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetPathNoDefect 2 sonetPathSTSLOP 4 sonetPathSTSAIS 8 sonetBIPE(BIP-8) 16 sonetFEBE 32 sonetPathSTSRDI 64 sonetPathUnequipped 128 sonetPathSignalLabelMismatch
1.3.6.1.4.1.9.10.27.1.1.8.1.12Integer32 (1..65535)read-onlycurrent
c64SonetAPSProtectSectionBIPE
OBJECT-TYPE
This object counts the number of section BIP-8 errors in protection channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.13Counter32read-onlycurrent
c64SonetAPSProtectLineBIPE
OBJECT-TYPE
This object counts the number of line BIP-8/24 errors in protection channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.14Counter32read-onlycurrent
c64SonetAPSProtectLineFEBE
OBJECT-TYPE
This object counts the number of line far-end-block-errors in protection channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.15Counter32read-onlycurrent
c64SonetAPSProtectPathBIPE
OBJECT-TYPE
This object counts the number of path BIP-8 errors in protection channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.16Counter32read-onlycurrent
c64SonetAPSProtectPathFEBE
OBJECT-TYPE
This object counts the number of path far-end-block-errors in protection channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.17Counter32read-onlycurrent
c64SonetAPSProtectPortStatus
OBJECT-TYPE
This object indicates the last aps event detected in protection port.
1.3.6.1.4.1.9.10.27.1.1.8.1.18APSEventStatusread-onlycurrent
c64SonetAPSChannelStatus
OBJECT-TYPE
This object indicates the last aps event detected in the APS channel.
1.3.6.1.4.1.9.10.27.1.1.8.1.19APSEventStatusread-onlycurrent
c64ChassisGroup
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.1.2
c64TelcoAlarmMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.1.2.1
c64ChassisFacilityAlarmStatus
OBJECT-TYPE
This object is an OR bit mask indicating the presence of critical/major/minor telco alarm: Bit 0, if set, indicates the presence of minor alarm Bit 1, if set, indicates the presence of major alarm Bit 2, if set, indicates the presence of critical alarm
1.3.6.1.4.1.9.10.27.1.2.1.1Integer32 (0..65535)read-onlycurrent
c64ChassisClearAlarms
OBJECT-TYPE
This object is used to clear all, major or minor alarms indication and reset the alarm contacts. When the clear command is done the value of this object will be set to done(0).
1.3.6.1.4.1.9.10.27.1.2.1.2INTEGER {done(0), all(1), minor(2), major(3), critical(4)}read-writecurrent
c64ChassisTempIntakeMinorThreshold
OBJECT-TYPE
This object is used to set the intake minor temperature alarm threshold in degrees centigrade. The default value is ???.
1.3.6.1.4.1.9.10.27.1.2.1.3INTEGER (20..57)read-writecurrent
c64ChassisTempIntakeMajorThreshold
OBJECT-TYPE
This object is used to set the intake major temperature alarm threshold in degrees centigrade. The default value is ???.
1.3.6.1.4.1.9.10.27.1.2.1.4INTEGER (20..57)read-writecurrent
c64ChassisTempCoreMinorThreshold
OBJECT-TYPE
This object is used to set the core minor temperature alarm threshold in degrees centigrade. The default value is ???.
1.3.6.1.4.1.9.10.27.1.2.1.5INTEGER (20..60)read-writecurrent
c64ChassisTempCoreMajorThreshold
OBJECT-TYPE
This object is used to set the core major temperature alarm threshold in degrees centigrade. The default value is ???.
1.3.6.1.4.1.9.10.27.1.2.1.6INTEGER (20..60)read-writecurrent
c64ChassisTempThresholdAdmin
OBJECT-TYPE
This object is used to enable/disable various threshold limit. Bit 0, if set to 0 disable the intake minor threshold otherwise enable it. Bit 1, if set to 0 disable the intake major threshold otherwise enable it. Bit 2, if set to 0 disable the core minor threshold otherwise enable it. Bit 3, if set to 0 disable the core major threshold otherwise enable it.
1.3.6.1.4.1.9.10.27.1.2.1.7Integer32 (0..65535)read-writecurrent
c64ChassisAlarmTable
OBJECT-TYPE
The table contains the current alarm status in the system.
1.3.6.1.4.1.9.10.27.1.2.2not-accessiblecurrent
c64ChassisAlarmEntry
OBJECT-TYPE
Entry containing alarm information occurred in the system.
1.3.6.1.4.1.9.10.27.1.2.2.1not-accessiblecurrent
c64ChassisAlarmIndex
OBJECT-TYPE
An arbitrary integer value to uniquely identify a alarm information entry.
1.3.6.1.4.1.9.10.27.1.2.2.1.1INTEGER (1..65535)read-onlycurrent
c64ChassisAlarmSource
OBJECT-TYPE
This object indicates the source of alarm. The variable will contain string in the following formats: 'Chassis' indicate the chassis alarms 'Submodule' indicate the submodule alarms 'port@slot#/subslot#/port#' indicate the port alarms. NMS app. will need to recognize the above three format in order to tell the alarm sources. The value other than the above three format cannot be allowed.
1.3.6.1.4.1.9.10.27.1.2.2.1.2DisplayStringread-onlycurrent
c64ChassisAlarmType
OBJECT-TYPE
This object indicates the type of alarm.
1.3.6.1.4.1.9.10.27.1.2.2.1.3INTEGER {coreTemp(1), inletTemp(2), totalFanFail(3), partialFanFail(4), fanMissing(5), pem0Fail(6), pem1Fail(7), sonetLineFail(8), cardOIRAlarm(9), cardFail(10), cardPartialFail(11), linkDownAlarm(12), networkClockAlarm(13), nrpSARFail(14), nrpPAMDataError(15), diskAlarm(16), imageAlarm(17), nrpBootUpAlarm(18), nrpSwitchoverAlarm(19), nrpSecondaryFailureAlarm(20), nrpSecondaryRemovedAlarm(21), nrpMismatchAlarm(22)}read-onlycurrent
c64ChassisAlarmSeverity
OBJECT-TYPE
This object indicates the severity of the alarm.
1.3.6.1.4.1.9.10.27.1.2.2.1.4INTEGER {minor(1), major(2), critical(3)}read-onlycurrent
c64ChassisAlarmACOStatus
OBJECT-TYPE
This object indicates whether the audible/visible local alarm relay has been locally cut off for this particular alarm source. When this status is 'normal', the alarm in this entry has closed the local audible/visible alarm relay contacts. When this status is 'cutoff', the alarm in this entry initially closed the local relay contacts, but was suppressed by a local user pressing the external ACO button on the 6400 NSP.
1.3.6.1.4.1.9.10.27.1.2.2.1.5INTEGER {normal(1), cutoff(2)}read-onlycurrent
cisco6400ChassisMIBNotificationPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.2
cisco6400ChassisMIBNotification
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.2.0
cisco6400ChassisMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.3
cisco6400ChassisMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.3.1
cisco6400ChassisMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9.10.27.3.2

Notifications

NameOIDStatus
cisco6400ChassisFailureNotification
NOTIFICATION-TYPE
The notification signifies that the agent detects a change in the c64ChassisAlarmTable, the NMS application should start to poll the c64ChassisAlarmTable to get up-to-date alarm information.
1.3.6.1.4.1.9.10.27.2.0.1current

Conformance

NameOIDStatus
cisco6400ChassisMIBCompliance
MODULE-COMPLIANCE
The compliance statement for 6400s, used in Santa NSP, which implement the Cisco 6400 Chassis MIB. This compliance statement is deprecated as some objects were deprecated in cisco6400RedundantGroup.
1.3.6.1.4.1.9.10.27.3.1.1deprecated
cisco6400ChassisMIBCompliance2
MODULE-COMPLIANCE
The compliance statement for 6400s, used in Santa NSP, which implement the Cisco 6400 Chassis MIB
1.3.6.1.4.1.9.10.27.3.1.2current
cisco6400RedundantGroup
OBJECT-GROUP
A collection of objects providing satan redundancy config. and information. This RFC 2155-level group was deprecated when the c64SlotConfigPrefIndex and c64SubSlotConfigPrefIndex objects were deprecated.
1.3.6.1.4.1.9.10.27.3.2.1deprecated
cisco6400ChassisMIBGroup
OBJECT-GROUP
A collection of objects providing santa telco alarm information.
1.3.6.1.4.1.9.10.27.3.2.2current
cisco6400RedundantGroup2
OBJECT-GROUP
A collection of objects providing satan redundancy config. and information.
1.3.6.1.4.1.9.10.27.3.2.3current