MIBs Depot

CERENT-GENERIC-MIB

Registered at
1.3.6.1.4.1.3607.1.10.40
1.3.6.1.4.1.3607.2.10
1.3.6.1.4.1.3607.2.20
1.3.6.1.4.1.3607.5.10
Last updated
1904-10-01 00:00
Organization
Cisco Systems, Inc.
Revisions
1904-10-01 00:00
Namespace
cerent
Source file
CERENT-GENERIC-MIB
Digest
sha256:ff4bc046ec295d37d087a131aa3021db0019ef0f878b1cd031eca7143870f5f9

Description

This module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.

Contact

support@Cisco.com Postal: Cisco Systems 1450 N. McDowell Blvd. Petaluma, CA 94954 USA Tel: +1-877-323-7368

Imports

FromSymbols
CERENT-GLOBAL-REGISTRYcerentGeneric, cerentModules, cerentRequirements
CERENT-TCCerentAlarmServiceAffecting, CerentAlarmSeverity, CerentAlarmStatus, CerentLocation, CerentMonitorType, CerentNotificationClass, CerentPeriod, CerentPortNumber
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CERENT-GENERIC-MIB
CERENT-GLOBAL-REGISTRY
CERENT-TC
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
CerentGenericAlarmType
TEXTUAL-CONVENTION
This TC is used by the NMS to map the alarm type received by the trap and and display the string shown in LHS.
current
CerentGenericEntityClass
TEXTUAL-CONVENTION
This is the TC used to find out to which cerentGenericEntityClass an alarm belongs to.
current

Objects

NameOIDSyntaxAccessStatus
cerentGenericObjects
OBJECT-IDENTITY
All the generic objects definitions are grouped under this
1.3.6.1.4.1.3607.2.10current
cerentGenericCommonObjectsGroup
OBJECT-IDENTITY
The group to combine all the Cisco OTBU common objects
1.3.6.1.4.1.3607.2.10.10current
cerentGenericEnableNotification
OBJECT-TYPE
This variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system.
1.3.6.1.4.1.3607.2.10.10.10TruthValueread-writecurrent
cerentGenericNodeTime
OBJECT-TYPE
Indicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. If the last octet is S then the time is standard time. Otherwise it is D to indicate it is daylight saving time, if applicable
1.3.6.1.4.1.3607.2.10.10.20DisplayStringread-onlycurrent
cerentGenericSentNotifications
OBJECT-TYPE
A count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start.
1.3.6.1.4.1.3607.2.10.10.30Counter32read-onlycurrent
cerentGenericLastChangeTime
OBJECT-TYPE
The value of sysUpTime at the time a conceptual row is created or deleted in cerentGenericAlarmTable
1.3.6.1.4.1.3607.2.10.10.40TimeStampread-onlycurrent
cerentGenericMultishelfEnabled
OBJECT-TYPE
This variable indicates whether the system is configured in multi-shelf mode or single-shelf mode.
1.3.6.1.4.1.3607.2.10.10.50TruthValueread-onlycurrent
cerentGenericGeneralGroup
OBJECT-IDENTITY
Another class of objects found in Cisco ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.20current
cerentGenericSoftwareVersion
OBJECT-TYPE
Indicates the version of software that is used in Cisco ONS Network element, ONS 15327, 15310. E.g., 2.2.03
1.3.6.1.4.1.3607.2.10.20.10DisplayStringread-onlycurrent
cerentGenericAlarmGroup
OBJECT-IDENTITY
The group that will represent all the alarm info in the Cisco ONS network element, ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.30current
cerentGenericAlarmCount
OBJECT-TYPE
Total number of active alarms in the Cisco ONS network element, ONS 15327, 15310. This equals the total number of rows in cerentGenericAlarmTable at any time.
1.3.6.1.4.1.3607.2.10.30.10Unsigned32read-onlycurrent
cerentGenericAlarmTable
OBJECT-TYPE
This table has all currently raised conditions for the network node. A Condition is a fault or status detected by hardware or software.
1.3.6.1.4.1.3607.2.10.30.20not-accessiblecurrent
cerentGenericAlarmEntry
OBJECT-TYPE
Row definition for cerentGenericAlarmTable
1.3.6.1.4.1.3607.2.10.30.20.1not-accessiblecurrent
cerentGenericAlarmIndex
OBJECT-TYPE
Uniquely identifies each entry in alarm table. May not start with one and there may be some missing numbers.
1.3.6.1.4.1.3607.2.10.30.20.1.10Integer32 (1..2147483647)not-accessiblecurrent
cerentGenericAlarmObjectType
OBJECT-TYPE
This will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm
1.3.6.1.4.1.3607.2.10.30.20.1.20CerentGenericEntityClassread-onlycurrent
cerentGenericAlarmSlotNumber
OBJECT-TYPE
This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.20.1.30Integer32read-onlycurrent
cerentGenericAlarmPortNumber
OBJECT-TYPE
This will indicate what is the port of the object which raised this alarm.
1.3.6.1.4.1.3607.2.10.30.20.1.40CerentPortNumberread-onlycurrent
cerentGenericAlarmLineNumber
OBJECT-TYPE
This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.20.1.50Integer32read-onlycurrent
cerentGenericAlarmObjectIndex
OBJECT-TYPE
Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this index is the index of the interface in the interface table.
1.3.6.1.4.1.3607.2.10.30.20.1.60Integer32read-onlycurrent
cerentGenericAlarmType
OBJECT-TYPE
Indicates what the exact nature of the alarm. See the CerentGenericAlarmType TC for mapping details
1.3.6.1.4.1.3607.2.10.30.20.1.70CerentGenericAlarmTyperead-onlycurrent
cerentGenericAlarmState
OBJECT-TYPE
Specifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} alarms and standing conditions will be represented here. However, this mib object is included in each trap dispatched and in the trap this object can contain all the possible values of CerentNotificationClass type.
1.3.6.1.4.1.3607.2.10.30.20.1.80CerentNotificationClassread-onlycurrent
cerentGenericAlarmTimeStamp
OBJECT-TYPE
The value of sysUpTime when this entry was created. This is accurate only upto a second.
1.3.6.1.4.1.3607.2.10.30.20.1.90TimeStampread-onlycurrent
cerentGenericAlarmObjectName
OBJECT-TYPE
TL1-style user-visible name which uniquely identifies an object in the system
1.3.6.1.4.1.3607.2.10.30.20.1.100DisplayStringread-onlycurrent
cerentGenericAlarmAdditionalInfo
OBJECT-TYPE
Additional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.
1.3.6.1.4.1.3607.2.10.30.20.1.110DisplayStringread-onlycurrent
cerentGenericAlarmSeverity
OBJECT-TYPE
Specifies severity of the alarm being sent out.
1.3.6.1.4.1.3607.2.10.30.20.1.120CerentAlarmSeverityread-onlycurrent
cerentGenericAlarmStatus
OBJECT-TYPE
Represents if an alarm is currently raised or cleared.
1.3.6.1.4.1.3607.2.10.30.20.1.130CerentAlarmStatusread-onlycurrent
cerentGenericAlarmServiceAffecting
OBJECT-TYPE
Specifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
1.3.6.1.4.1.3607.2.10.30.20.1.140CerentAlarmServiceAffectingread-onlycurrent
cerentGenericReportedAlarmCount
OBJECT-TYPE
Number of alarms currently reported against Cisco ONS platform. This equals the number of rows in cerentGenericReportedAlarmTable.
1.3.6.1.4.1.3607.2.10.30.30Unsigned32read-onlycurrent
cerentGenericReportedAlarmTable
OBJECT-TYPE
This table has the list of alarms currently reported for the Cisco ONS node. It does not include any cleared alarms. The alarms in this table are in compliance with Telcordia GR-253. This means that if a network problem causes two alarms, such a as loss of frame(LOF) and loss of signal(LOS), only LOS alarm will be in this table because it supersedes and replaces the LOF.
1.3.6.1.4.1.3607.2.10.30.40not-accessiblecurrent
cerentGenericReportedAlarmEntry
OBJECT-TYPE
Row definition for cerentGenericReportedAlarmTable
1.3.6.1.4.1.3607.2.10.30.40.1not-accessiblecurrent
cerentGenericReportedAlarmIndex
OBJECT-TYPE
Identifies each entry in ReportedAlarm table. May not start with one and there may be some missing numbers.
1.3.6.1.4.1.3607.2.10.30.40.1.10Integer32 (1..2147483647)not-accessiblecurrent
cerentGenericReportedAlarmObjectType
OBJECT-TYPE
This will indicate the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm
1.3.6.1.4.1.3607.2.10.30.40.1.20CerentGenericEntityClassread-onlycurrent
cerentGenericReportedAlarmSlotNumber
OBJECT-TYPE
This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
1.3.6.1.4.1.3607.2.10.30.40.1.30Integer32read-onlycurrent
cerentGenericReportedAlarmPortNumber
OBJECT-TYPE
This will indicate what is the port of the object which raised this alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.40CerentPortNumberread-onlycurrent
cerentGenericReportedAlarmObjectIndex
OBJECT-TYPE
Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this is the index of the interface in the interface table.
1.3.6.1.4.1.3607.2.10.30.40.1.50Integer32read-onlycurrent
cerentGenericReportedAlarmType
OBJECT-TYPE
Indicates the exact nature of the alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.60CerentGenericAlarmTyperead-onlycurrent
cerentGenericReportedAlarmTimeStamp
OBJECT-TYPE
The value of sysUpTime when this entry was created. This is accurate only upto a second.
1.3.6.1.4.1.3607.2.10.30.40.1.70TimeStampread-onlycurrent
cerentGenericReportedAlarmObjectName
OBJECT-TYPE
TL1-style user-visible name which uniquely identifies an object in the system
1.3.6.1.4.1.3607.2.10.30.40.1.80DisplayStringread-onlycurrent
cerentGenericReportedAlarmAdditionalInfo
OBJECT-TYPE
Additional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.
1.3.6.1.4.1.3607.2.10.30.40.1.90DisplayStringread-onlycurrent
cerentGenericReportedAlarmSeverity
OBJECT-TYPE
Specifies severity of the alarm.
1.3.6.1.4.1.3607.2.10.30.40.1.100CerentAlarmSeverityread-onlycurrent
cerentGenericReportedAlarmStatus
OBJECT-TYPE
Represents if the alarm is currently raised or cleared.
1.3.6.1.4.1.3607.2.10.30.40.1.110CerentAlarmStatusread-onlycurrent
cerentGenericReportedAlarmServiceAffecting
OBJECT-TYPE
Specifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
1.3.6.1.4.1.3607.2.10.30.40.1.120CerentAlarmServiceAffectingread-onlycurrent
cerentGenericThresholdGroup
OBJECT-IDENTITY
The group that will represent all the threshold info in the Cisco ONS network element, ONS 15327, 15310
1.3.6.1.4.1.3607.2.10.40current
cerentGenericThresholdTable
OBJECT-TYPE
This table holds all the provisioned Thresholds. This table is currently unimplemented.
1.3.6.1.4.1.3607.2.10.40.10not-accessiblecurrent
cerentGenericThresholdEntry
OBJECT-TYPE
Row definition for cerentGenericThresholdTable
1.3.6.1.4.1.3607.2.10.40.10.1not-accessiblecurrent
cerentGenericThresholdIndex
OBJECT-TYPE
Uniquely identifies each entry in Threshold table. May not start with one and there will be some missing numbers.
1.3.6.1.4.1.3607.2.10.40.10.1.10Integer32 (1..2147483647)not-accessiblecurrent
cerentGenericThresholdMonitorType
OBJECT-TYPE
This object indicates the type of metric monitored.
1.3.6.1.4.1.3607.2.10.40.10.1.20CerentMonitorTyperead-onlycurrent
cerentGenericThresholdLocation
OBJECT-TYPE
This indicates if it near or far end
1.3.6.1.4.1.3607.2.10.40.10.1.30CerentLocationread-onlycurrent
cerentGenericThresholdPeriod
OBJECT-TYPE
The sampling interval period is indicated here
1.3.6.1.4.1.3607.2.10.40.10.1.40CerentPeriodread-onlycurrent
cerentGenericThresholdSetValue
OBJECT-TYPE
The value of this object will be threshold that was provisioned by the NMS
1.3.6.1.4.1.3607.2.10.40.10.1.50Integer32read-onlycurrent
cerentGenericThresholdCurrentValue
OBJECT-TYPE
The current value of the counter which measures the metric. This column will never be implemented as these values are already accessible through IETF MIB objects.
1.3.6.1.4.1.3607.2.10.40.10.1.60Integer32read-onlycurrent
cerentGenericThresholdDetectType
OBJECT-TYPE
The value of this object will be the detect type for the threshold.
1.3.6.1.4.1.3607.2.10.40.10.1.70INTEGER {unknown(1), none(10), mon(20), term(30)}read-onlycurrent
cerentGenericEvents
OBJECT-IDENTITY
Place holder for all notifications of Cisco ONS network device, ONS 15327, 15310
1.3.6.1.4.1.3607.2.20current
cerentGenericV2Events
OBJECT-IDENTITY
The sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds.
1.3.6.1.4.1.3607.2.20.0current
cerentConformance
OBJECT-IDENTITY
This node is created for compliance. Has objects as required by the RFCs
1.3.6.1.4.1.3607.5.10current
cerentGenericGroups
OBJECT-IDENTITY
All the objects and events are grouped under this for conformance
1.3.6.1.4.1.3607.5.10.10current
cerentCompliance
OBJECT-IDENTITY
The compliance statements for Cisco ONS 15327, 15310.
1.3.6.1.4.1.3607.5.10.20current

Notifications

NameOIDStatus
galarmUnknown
NOTIFICATION-TYPE
alarm unknown
1.3.6.1.4.1.3607.2.20.0.1current
galarmCutoffIsInManualMode
NOTIFICATION-TYPE
alarm cutoff is in manual mode
1.3.6.1.4.1.3607.2.20.0.10current
gfailureDetectedExternalToTheNE
NOTIFICATION-TYPE
failure detected External to the NE
1.3.6.1.4.1.3607.2.20.0.20current
gexternalError
NOTIFICATION-TYPE
external error
1.3.6.1.4.1.3607.2.20.0.30current
gexcessiveSwitching
NOTIFICATION-TYPE
excessive switching
1.3.6.1.4.1.3607.2.20.0.40current
gsdccTerminationFailure
NOTIFICATION-TYPE
SDCC Termination failure
1.3.6.1.4.1.3607.2.20.0.50current
gincomingFailureCondition
NOTIFICATION-TYPE
incoming failure condition
1.3.6.1.4.1.3607.2.20.0.60current
galarmIndicationSignal
NOTIFICATION-TYPE
alarm indication signal
1.3.6.1.4.1.3607.2.20.0.70current
galarmIndicationSignalLine
NOTIFICATION-TYPE
alarm indication signal LINE
1.3.6.1.4.1.3607.2.20.0.80current
galarmIndicationSignalPath
NOTIFICATION-TYPE
alarm indication signal Path
1.3.6.1.4.1.3607.2.20.0.90current
galarmIndicationSignalVT
NOTIFICATION-TYPE
alarm indication signal VT
1.3.6.1.4.1.3607.2.20.0.100current
gapsChannelFailure
NOTIFICATION-TYPE
channel failure APS
1.3.6.1.4.1.3607.2.20.0.110current
gchannelByteFailureAPS
NOTIFICATION-TYPE
channel Byte failure APS
1.3.6.1.4.1.3607.2.20.0.120current
gchannelProtectionSwitchingChannelMatchFailureAPS
NOTIFICATION-TYPE
channel Protection Switching Channel Match failure APS
1.3.6.1.4.1.3607.2.20.0.130current
gchannelAutomaticProtectionSwitchModeMismatchAPS
NOTIFICATION-TYPE
channel Automatic Protection Switch Mode Mismatch APS
1.3.6.1.4.1.3607.2.20.0.140current
gfarEndProtectionLineFailure
NOTIFICATION-TYPE
channel far end protection line failure APS
1.3.6.1.4.1.3607.2.20.0.150current
ginconsistentAPSCode
NOTIFICATION-TYPE
Inconsistent APS code
1.3.6.1.4.1.3607.2.20.0.160current
gimproperAPSCode
NOTIFICATION-TYPE
Improper APS code APS
1.3.6.1.4.1.3607.2.20.0.170current
gnodeIdMismatch
NOTIFICATION-TYPE
Node Id Mismatch APS
1.3.6.1.4.1.3607.2.20.0.180current
gchannelDefaultKAPS
NOTIFICATION-TYPE
Default K APS
1.3.6.1.4.1.3607.2.20.0.190current
gconnectionLoss
NOTIFICATION-TYPE
Connection loss APS
1.3.6.1.4.1.3607.2.20.0.200current
gbipolarViolation
NOTIFICATION-TYPE
bipolar Violation
1.3.6.1.4.1.3607.2.20.0.210current
gcarrierLossOnTheLAN
NOTIFICATION-TYPE
carrier Loss on the LAN
1.3.6.1.4.1.3607.2.20.0.220current
gconcatenationErrorSTS
NOTIFICATION-TYPE
concatenation error STS
1.3.6.1.4.1.3607.2.20.0.230current
gexcessCollisionsOnTheLAN
NOTIFICATION-TYPE
excess collisions on the LAN
1.3.6.1.4.1.3607.2.20.0.240current
gfacilityFailure
NOTIFICATION-TYPE
facility critical alarm caused by DS3 facility failure
1.3.6.1.4.1.3607.2.20.0.250current
gfarEndAIS
NOTIFICATION-TYPE
far end AIS
1.3.6.1.4.1.3607.2.20.0.260current
gfarEndMultipleDS1LOSDetectedOnDS3
NOTIFICATION-TYPE
far end Multiple DS1 LOS detected on DS3
1.3.6.1.4.1.3607.2.20.0.270current
gfarEndDS1EqptFailNonServiceAffecting
NOTIFICATION-TYPE
far end DS1 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.280current
gfarEndDS1EqptFailServiceAffecting
NOTIFICATION-TYPE
far end DS1 Eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.290current
gfarEndSingleDS1LOS
NOTIFICATION-TYPE
far end Single DS1 LOS
1.3.6.1.4.1.3607.2.20.0.300current
gfarEndDS3EqptFailNonServiceAffecting
NOTIFICATION-TYPE
far end DS3 Eqpt failure non service affecting
1.3.6.1.4.1.3607.2.20.0.310current
gfarEndDS3EqptFailServiceAffecting
NOTIFICATION-TYPE
far end DS3 Eqpt failure service affecting
1.3.6.1.4.1.3607.2.20.0.320current
gfarEndCommonEquipmentFailureNonServiceAffecting
NOTIFICATION-TYPE
far end common Eqpt failure non service affecting
1.3.6.1.4.1.3607.2.20.0.330current
gfarEndIDLE
NOTIFICATION-TYPE
far end IDLE
1.3.6.1.4.1.3607.2.20.0.340current
gfarEndLOS
NOTIFICATION-TYPE
far end LOS
1.3.6.1.4.1.3607.2.20.0.350current
gfarEndLOF
NOTIFICATION-TYPE
far end LOF
1.3.6.1.4.1.3607.2.20.0.360current
gfarEndBlockError
NOTIFICATION-TYPE
far End Block Error
1.3.6.1.4.1.3607.2.20.0.370current
gds3IdleCondition
NOTIFICATION-TYPE
idle Condition DS3
1.3.6.1.4.1.3607.2.20.0.380current
glossOfFrame
NOTIFICATION-TYPE
loss of Frame
1.3.6.1.4.1.3607.2.20.0.390current
glossOfPointer
NOTIFICATION-TYPE
loss of Pointer
1.3.6.1.4.1.3607.2.20.0.400current
glossOfPointerPath
NOTIFICATION-TYPE
loss of Pointer Path
1.3.6.1.4.1.3607.2.20.0.410current
glossOfPointerVT
NOTIFICATION-TYPE
loss of Pointer VT
1.3.6.1.4.1.3607.2.20.0.420current
glossOfSignal
NOTIFICATION-TYPE
loss of Signal
1.3.6.1.4.1.3607.2.20.0.430current
goutOfFrame
NOTIFICATION-TYPE
out of Frame
1.3.6.1.4.1.3607.2.20.0.440current
gpathSelectorFailure
NOTIFICATION-TYPE
path Selector inability to swtich to a valid signal
1.3.6.1.4.1.3607.2.20.0.450current
gremoteAlarmIndication
NOTIFICATION-TYPE
remote Alarm Indication
1.3.6.1.4.1.3607.2.20.0.460current
gremoteFailureIndication
NOTIFICATION-TYPE
remote Failure Indication
1.3.6.1.4.1.3607.2.20.0.470current
gremoteFailureIndicationLine
NOTIFICATION-TYPE
remote Failure Indication LINE
1.3.6.1.4.1.3607.2.20.0.480current
gremoteFailureIndicationPath
NOTIFICATION-TYPE
remote Failure Indication Path
1.3.6.1.4.1.3607.2.20.0.490current
gremoteFailureIndicationVT
NOTIFICATION-TYPE
remote Failure Indication VT
1.3.6.1.4.1.3607.2.20.0.500current
gsignalDegrade
NOTIFICATION-TYPE
Signal Degrade
1.3.6.1.4.1.3607.2.20.0.510current
gseverelyErroredFrame
NOTIFICATION-TYPE
severely Errored Frame
1.3.6.1.4.1.3607.2.20.0.520current
gsignalFailure
NOTIFICATION-TYPE
Signal Failure
1.3.6.1.4.1.3607.2.20.0.530current
gsignalLabelMismatchFailure
NOTIFICATION-TYPE
signal Label Mismatch Failures
1.3.6.1.4.1.3607.2.20.0.540current
gpayloadDefectIndication
NOTIFICATION-TYPE
Payload Defect Indication
1.3.6.1.4.1.3607.2.20.0.550current
gpayloadDefectIndicationPath
NOTIFICATION-TYPE
Payload Defect Indication - Path
1.3.6.1.4.1.3607.2.20.0.560current
gpayloadLabelMismatchPath
NOTIFICATION-TYPE
Payload Label Mismatch - Path
1.3.6.1.4.1.3607.2.20.0.570current
gsignalLabelMismatchFailurePayloadLabelMismatchVT
NOTIFICATION-TYPE
signal Label Mismatch Failure Payload Label Mismatch VT
1.3.6.1.4.1.3607.2.20.0.580current
gunequippedPath
NOTIFICATION-TYPE
Unequipped - Path
1.3.6.1.4.1.3607.2.20.0.590current
gsignalLabelMismatchFailureUnequippedVT
NOTIFICATION-TYPE
signal Label Mismatch Failure Unequipped VT
1.3.6.1.4.1.3607.2.20.0.600current
glossOfSynchronization
NOTIFICATION-TYPE
Loss of Synchronization
1.3.6.1.4.1.3607.2.20.0.610current
goutOfSynchronization
NOTIFICATION-TYPE
Out of Synchronization
1.3.6.1.4.1.3607.2.20.0.620current
gprimarySynchronizationReferenceFailure
NOTIFICATION-TYPE
Primary Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.630current
gsecondarySynchronizationReferenceFailure
NOTIFICATION-TYPE
Secondary Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.640current
gthirdSynchronizationReferenceFailure
NOTIFICATION-TYPE
Third Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.650current
gfourthSynchronizationReferenceFailure
NOTIFICATION-TYPE
Fourth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.660current
gfifthSynchronizationReferenceFailure
NOTIFICATION-TYPE
Fifth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.670current
gsixthSynchronizationReferenceFailure
NOTIFICATION-TYPE
Sixth Synchronization Reference Failure
1.3.6.1.4.1.3607.2.20.0.680current
gfailedToReceiveSynchronizationStatusMessage
NOTIFICATION-TYPE
failed to receive Synchronization Status Message
1.3.6.1.4.1.3607.2.20.0.690current
gsynchronizationStatusMessagesAreDisabledOnThisInterface
NOTIFICATION-TYPE
synchronization Status Messages are disabled on this interface
1.3.6.1.4.1.3607.2.20.0.700current
gstratum1PrimaryReferenceSourceTraceable
NOTIFICATION-TYPE
Stratum1 Primary Reference Source Traceable
1.3.6.1.4.1.3607.2.20.0.710current
gsynchronizedTraceabilityUnknown
NOTIFICATION-TYPE
synchronized Traceability Unknown
1.3.6.1.4.1.3607.2.20.0.720current
gstratum2Traceable
NOTIFICATION-TYPE
stratum 2 Traceable
1.3.6.1.4.1.3607.2.20.0.730current
gtransitNodeClockTraceable
NOTIFICATION-TYPE
transit Node clock Traceable
1.3.6.1.4.1.3607.2.20.0.740current
gstratum3ETraceable
NOTIFICATION-TYPE
stratum 3E Traceable
1.3.6.1.4.1.3607.2.20.0.750current
gstratum3Traceable
NOTIFICATION-TYPE
stratum 3 Traceable
1.3.6.1.4.1.3607.2.20.0.760current
gsonetMinimumClockTraceable
NOTIFICATION-TYPE
Minimum clock Traceable - SONET
1.3.6.1.4.1.3607.2.20.0.770current
gstratum4Traceable
NOTIFICATION-TYPE
stratum 4 Traceable
1.3.6.1.4.1.3607.2.20.0.780current
gdoNotUseForSynchronization
NOTIFICATION-TYPE
do not Use for Synchronization
1.3.6.1.4.1.3607.2.20.0.790current
greservedForNetworkSynchronizationUse
NOTIFICATION-TYPE
reserved for Network Synchronization Use
1.3.6.1.4.1.3607.2.20.0.800current
goutgoingFailureCondition
NOTIFICATION-TYPE
outgoing failure condition
1.3.6.1.4.1.3607.2.20.0.810current
gremoteDefectIndicationLine
NOTIFICATION-TYPE
remote Defect Indication LINE
1.3.6.1.4.1.3607.2.20.0.820current
gremoteDefectIndicationPath
NOTIFICATION-TYPE
remote Defect Indication Path
1.3.6.1.4.1.3607.2.20.0.830current
gfreeRunningSynchronizationMode
NOTIFICATION-TYPE
free Running Synchronization mode
1.3.6.1.4.1.3607.2.20.0.840current
gholdoverSynchronizationMode
NOTIFICATION-TYPE
holdover synchronization mode
1.3.6.1.4.1.3607.2.20.0.850current
gfastStartSynchronizationMode
NOTIFICATION-TYPE
fast Start synchronization mode
1.3.6.1.4.1.3607.2.20.0.860current
ginternalFault
NOTIFICATION-TYPE
internal hardware fault or failure
1.3.6.1.4.1.3607.2.20.0.870current
ginternalError
NOTIFICATION-TYPE
error Internal to the NE Detected
1.3.6.1.4.1.3607.2.20.0.880current
ginternalMessageError
NOTIFICATION-TYPE
internal Message Error
1.3.6.1.4.1.3607.2.20.0.890current
gmismatchOfEquipmentAndAttributes
NOTIFICATION-TYPE
mismatch of Equipment and Attributes
1.3.6.1.4.1.3607.2.20.0.900current
gwatchdogTimerTimeout
NOTIFICATION-TYPE
watchdog Timer Timeout
1.3.6.1.4.1.3607.2.20.0.910current
gsoftwareFaultOrFailure
NOTIFICATION-TYPE
software Fault or failure
1.3.6.1.4.1.3607.2.20.0.920current
gsoftwareFaultDataIntegrityFault
NOTIFICATION-TYPE
software Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added object(s) in the system has(have) enough memory to exist onboard but too large to be saved in the database.
1.3.6.1.4.1.3607.2.20.0.930current
gprogramFailure
NOTIFICATION-TYPE
program failure
1.3.6.1.4.1.3607.2.20.0.940current
gcontrolEquipmentFailure
NOTIFICATION-TYPE
control Equipment failure
1.3.6.1.4.1.3607.2.20.0.950current
gprimaryNonVolatileBackupMemoryFailure
NOTIFICATION-TYPE
control Equipment Primary non volatile Backup Memory failure
1.3.6.1.4.1.3607.2.20.0.960current
gsecondaryNonVolatileBackupMemoryFailure
NOTIFICATION-TYPE
control Equipment Secondary non volatile Backup Memory failure
1.3.6.1.4.1.3607.2.20.0.970current
gcontrolBusFailure
NOTIFICATION-TYPE
control Equipment Control Bus failure
1.3.6.1.4.1.3607.2.20.0.980current
gcontrolBus1Failure
NOTIFICATION-TYPE
control Equipment Control Bus 1 failure
1.3.6.1.4.1.3607.2.20.0.990current
gcontrolBus2Failure
NOTIFICATION-TYPE
control Equipment Control Bus 2 failure
1.3.6.1.4.1.3607.2.20.0.1000current
gtccAToShelfSlot1DROP1CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 1
1.3.6.1.4.1.3607.2.20.0.1010current
gtccAToShelfSlot2DROP2CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 2
1.3.6.1.4.1.3607.2.20.0.1020current
gtccAToShelfSlot3DROP3CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 3
1.3.6.1.4.1.3607.2.20.0.1030current
gtccAToShelfSlot4DROP4CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 4
1.3.6.1.4.1.3607.2.20.0.1040current
gtccAToShelfSlot5TRUNK1CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 5
1.3.6.1.4.1.3607.2.20.0.1050current
gtccAToShelfSlot6TRUNK2CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 6
1.3.6.1.4.1.3607.2.20.0.1060current
gtccAToShelfSlot7TCCACommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 7
1.3.6.1.4.1.3607.2.20.0.1070current
gtccAToShelfSlot8XCONACommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 8
1.3.6.1.4.1.3607.2.20.0.1080current
gtccAToShelfSlot9AICCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 9
1.3.6.1.4.1.3607.2.20.0.1090current
gtccAToShelfSlot10XCONBCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 10
1.3.6.1.4.1.3607.2.20.0.1100current
gtccAToShelfSlot11TCCBCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 11
1.3.6.1.4.1.3607.2.20.0.1110current
gtccAToShelfSlot12TRUNK3CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 12
1.3.6.1.4.1.3607.2.20.0.1120current
gtccAToShelfSlot13TRUNK4CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 13
1.3.6.1.4.1.3607.2.20.0.1130current
gtccAToShelfSlot14DROP5CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 14
1.3.6.1.4.1.3607.2.20.0.1140current
gtccAToShelfSlot15DROP6CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 15
1.3.6.1.4.1.3607.2.20.0.1150current
gtccAToShelfSlot16DROP7CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 16
1.3.6.1.4.1.3607.2.20.0.1160current
gtccAToShelfSlot17DROP8CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller A to Shelf SLOT 17
1.3.6.1.4.1.3607.2.20.0.1170current
gtccAToDCCAProcessorCommunicationFailure
NOTIFICATION-TYPE
communication failure ControllerP A to ControllerJ A processor
1.3.6.1.4.1.3607.2.20.0.1180current
gtccBToShelfSlot1DROP1CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 1
1.3.6.1.4.1.3607.2.20.0.1190current
gtccBToShelfSlot2DROP2CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 2
1.3.6.1.4.1.3607.2.20.0.1200current
gtccBToShelfSlot3DROP3CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 3
1.3.6.1.4.1.3607.2.20.0.1210current
gtccBToShelfSlot4DROP4CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 4
1.3.6.1.4.1.3607.2.20.0.1220current
gtccBToShelfSlot5TRUNK1CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 5
1.3.6.1.4.1.3607.2.20.0.1230current
gtccBToShelfSlot6TRUNK2CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 6
1.3.6.1.4.1.3607.2.20.0.1240current
gtccBToShelfSlot7TCCACommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 7
1.3.6.1.4.1.3607.2.20.0.1250current
gtccBToShelfSlot8XCONACommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 8
1.3.6.1.4.1.3607.2.20.0.1260current
gtccBToShelfSlot9AICCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 9
1.3.6.1.4.1.3607.2.20.0.1270current
gtccBToShelfSlot10XCONBCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 10
1.3.6.1.4.1.3607.2.20.0.1280current
gtccBToShelfSlot11TCCBCommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 11
1.3.6.1.4.1.3607.2.20.0.1290current
gtccBToShelfSlot12TRUNK3CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 12
1.3.6.1.4.1.3607.2.20.0.1300current
gtccBToShelfSlot13TRUNK4CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 13
1.3.6.1.4.1.3607.2.20.0.1310current
gtccBToShelfSlot14DROP5CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 14
1.3.6.1.4.1.3607.2.20.0.1320current
gtccBToShelfSlot15DROP6CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 15
1.3.6.1.4.1.3607.2.20.0.1330current
gtccBToShelfSlot16DROP7CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 16
1.3.6.1.4.1.3607.2.20.0.1340current
gtccBToShelfSlot17DROP8CommunicationFailure
NOTIFICATION-TYPE
communication failure Controller B to Shelf SLOT 17
1.3.6.1.4.1.3607.2.20.0.1350current
gtccBToDCCBProcessorCommunicationFailure
NOTIFICATION-TYPE
communication failure ControllerP B to ControllerJ A processor
1.3.6.1.4.1.3607.2.20.0.1360current
gcontrolEquipmentControlCommunicationsEquipmentFailure
NOTIFICATION-TYPE
control Equipment Control Communications equipment failure
1.3.6.1.4.1.3607.2.20.0.1370deprecated
gcontrolProcessorFailure
NOTIFICATION-TYPE
control Equipment Control processor failure
1.3.6.1.4.1.3607.2.20.0.1380current
gworkingMemoryFailure
NOTIFICATION-TYPE
control Equipment Working memory failure
1.3.6.1.4.1.3607.2.20.0.1390current
ginterconnectionEquipmentFailure
NOTIFICATION-TYPE
interconnection Equipment failure
1.3.6.1.4.1.3607.2.20.0.1400current
gpayloadBusFailureToIOSlot1XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 1 Working
1.3.6.1.4.1.3607.2.20.0.1410current
gpayloadBusFailureToIOSlot2XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 2 Working
1.3.6.1.4.1.3607.2.20.0.1420current
gpayloadBusFailureToIOSlot3XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 3 Working
1.3.6.1.4.1.3607.2.20.0.1430current
gpayloadBusFailureToIOSlot4XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 4 Working
1.3.6.1.4.1.3607.2.20.0.1440current
gpayloadBusFailureToIOSlot5XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 5 Working
1.3.6.1.4.1.3607.2.20.0.1450current
gpayloadBusFailureToIOSlot6XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 6 Working
1.3.6.1.4.1.3607.2.20.0.1460current
gpayloadBusFailureToIOSlot12XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 7 Working
1.3.6.1.4.1.3607.2.20.0.1470current
gpayloadBusFailureToIOSlot13XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 8 Working
1.3.6.1.4.1.3607.2.20.0.1480current
gpayloadBusFailureToIOSlot14XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 9 Working
1.3.6.1.4.1.3607.2.20.0.1490current
gpayloadBusFailureToIOSlot15XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 10 Working
1.3.6.1.4.1.3607.2.20.0.1500current
gpayloadBusFailureToIOSlot16XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 11 Working
1.3.6.1.4.1.3607.2.20.0.1510current
gpayloadBusFailureToIOSlot17XCONSlot8
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 12 Working
1.3.6.1.4.1.3607.2.20.0.1520current
gpayloadBusFailureToIOSlot1XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 1 Protect
1.3.6.1.4.1.3607.2.20.0.1530current
gpayloadBusFailureToIOSlot2XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 2 Protect
1.3.6.1.4.1.3607.2.20.0.1540current
gpayloadBusFailureToIOSlot3XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 3 Protect
1.3.6.1.4.1.3607.2.20.0.1550current
gpayloadBusFailureToIOSlot4XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 4 Protect
1.3.6.1.4.1.3607.2.20.0.1560current
gpayloadBusFailureToIOSlot5XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 5 Protect
1.3.6.1.4.1.3607.2.20.0.1570current
gpayloadBusFailureToIOSlot6XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 6 Protect
1.3.6.1.4.1.3607.2.20.0.1580current
gpayloadBusFailureToIOSlot12XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 7 Protect
1.3.6.1.4.1.3607.2.20.0.1590current
gpayloadBusFailureToIOSlot13XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 8 Protect
1.3.6.1.4.1.3607.2.20.0.1600current
gpayloadBusFailureToIOSlot14XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 9 Protect
1.3.6.1.4.1.3607.2.20.0.1610current
gpayloadBusFailureToIOSlot15XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 10 Protect
1.3.6.1.4.1.3607.2.20.0.1620current
gpayloadBusFailureToIOSlot16XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 11 Protect
1.3.6.1.4.1.3607.2.20.0.1630current
gpayloadBusFailureToIOSlot17XCONSlot10
NOTIFICATION-TYPE
interconnection Equipment failure Payload Bus 12 Protect
1.3.6.1.4.1.3607.2.20.0.1640current
gtimeSlotInterchangeEquipmentFailure
NOTIFICATION-TYPE
interconnection Eqpt Time slot interchange eqpt failure
1.3.6.1.4.1.3607.2.20.0.1650current
gequipmentFailure
NOTIFICATION-TYPE
equipment failure
1.3.6.1.4.1.3607.2.20.0.1660current
ghighTemperature
NOTIFICATION-TYPE
High Temperature
1.3.6.1.4.1.3607.2.20.0.1670current
ginvalidMACAddress
NOTIFICATION-TYPE
equipment failure Invalid MAC Address
1.3.6.1.4.1.3607.2.20.0.1680current
gboardFailure
NOTIFICATION-TYPE
equipment failure Board Failure
1.3.6.1.4.1.3607.2.20.0.1690current
gdiagnosticFailure
NOTIFICATION-TYPE
equipment failure Diagnostics Failure
1.3.6.1.4.1.3607.2.20.0.1700current
gmediumAccessControlFailure
NOTIFICATION-TYPE
equipment failure Medium Access Control
1.3.6.1.4.1.3607.2.20.0.1710current
gfacilityTerminationEquipmentFailure
NOTIFICATION-TYPE
facility Termination equipment failure
1.3.6.1.4.1.3607.2.20.0.1720current
gautomaticLaserShutoffDueToHighTemperature
NOTIFICATION-TYPE
Automatic Laser Shutoff Due To High Temperature
1.3.6.1.4.1.3607.2.20.0.1730current
gfailureToReleaseFromProtection
NOTIFICATION-TYPE
failure To Release from protection
1.3.6.1.4.1.3607.2.20.0.1740current
greceiverFailure
NOTIFICATION-TYPE
facility Termination equipment Receiver failure
1.3.6.1.4.1.3607.2.20.0.1750current
gtransmitFailure
NOTIFICATION-TYPE
facility Termination equipment Transmit failure
1.3.6.1.4.1.3607.2.20.0.1760current
gfacilityTerminationEquipmentReceiverMissing
NOTIFICATION-TYPE
facility Termination equipment Receiver missing
1.3.6.1.4.1.3607.2.20.0.1770current
gfacilityTerminationEquipmentTransmitterMissing
NOTIFICATION-TYPE
facility Termination equipment Transmitter missing
1.3.6.1.4.1.3607.2.20.0.1780current
gfailureToSwitchToProtection
NOTIFICATION-TYPE
failure To Switch to protection
1.3.6.1.4.1.3607.2.20.0.1790current
gfailureToSwitchToProtectionRing
NOTIFICATION-TYPE
failure To Switch to protection Ring
1.3.6.1.4.1.3607.2.20.0.1800current
gfailureToSwitchToProtectionSpan
NOTIFICATION-TYPE
failure To Switch to protection Span
1.3.6.1.4.1.3607.2.20.0.1810current
gfailureToSwitchToProtectionPath
NOTIFICATION-TYPE
failure to Switch to protection Path
1.3.6.1.4.1.3607.2.20.0.1820current
gfanFailure
NOTIFICATION-TYPE
failure of cooling fan tray
1.3.6.1.4.1.3607.2.20.0.1830current
gequipmentUnitPlugIn
NOTIFICATION-TYPE
equipment unit plug in
1.3.6.1.4.1.3607.2.20.0.1840current
gnePowerFailureAtConnector
NOTIFICATION-TYPE
NE Power Failure At Connector
1.3.6.1.4.1.3607.2.20.0.1850current
gfuseAlarm
NOTIFICATION-TYPE
power failure Fuse Alarm
1.3.6.1.4.1.3607.2.20.0.1860current
gsynchronizationUnitFailure
NOTIFICATION-TYPE
synchronization unit failure
1.3.6.1.4.1.3607.2.20.0.1870current
gsynchronizationSwitchingEquipmentFailure
NOTIFICATION-TYPE
synchronization switching Equipment failure
1.3.6.1.4.1.3607.2.20.0.1880current
gequipmentUnitUnplugged
NOTIFICATION-TYPE
equipment unit un plug
1.3.6.1.4.1.3607.2.20.0.1890current
gloopback
NOTIFICATION-TYPE
loop back
1.3.6.1.4.1.3607.2.20.0.1900current
gds1LoopbackDueToFEACCommand
NOTIFICATION-TYPE
loopback due to FEAC command DS1
1.3.6.1.4.1.3607.2.20.0.1910current
gloopbackCommandSentToFarEndDS1
NOTIFICATION-TYPE
loopback Command sent to Far End DS1
1.3.6.1.4.1.3607.2.20.0.1920current
gds3LoopbackDueToFEACCommand
NOTIFICATION-TYPE
loopback due to FEAC command DS3
1.3.6.1.4.1.3607.2.20.0.1930current
gds3LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
loopback Command sent to Far End DS3
1.3.6.1.4.1.3607.2.20.0.1940current
gds2LoopbackDueToFarEndCommand
NOTIFICATION-TYPE
loopback due to Far End Command DS2
1.3.6.1.4.1.3607.2.20.0.1950current
gds2LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
loopback Command sent to Far End DS2
1.3.6.1.4.1.3607.2.20.0.1960current
gfacilityLoopback
NOTIFICATION-TYPE
loop back facility
1.3.6.1.4.1.3607.2.20.0.1970current
gnetworkLoopback
NOTIFICATION-TYPE
loop back Network
1.3.6.1.4.1.3607.2.20.0.1980current
gterminalLoopback
NOTIFICATION-TYPE
loop back Terminal
1.3.6.1.4.1.3607.2.20.0.1990current
gmanuallyCausedAbnormalCondition
NOTIFICATION-TYPE
manually caused abnormal condition
1.3.6.1.4.1.3607.2.20.0.2000current
gethernetBridgeIsNewRootOfSpanningTree
NOTIFICATION-TYPE
new Root discovered in bridged network
1.3.6.1.4.1.3607.2.20.0.2010current
gethernetBridgeTopologyChange
NOTIFICATION-TYPE
topology change discovered in bridged network
1.3.6.1.4.1.3607.2.20.0.2020current
gnormalCondition
NOTIFICATION-TYPE
normal condition
1.3.6.1.4.1.3607.2.20.0.2030current
gembeddedOperationsChannelFailureLinkDown
NOTIFICATION-TYPE
embedded Operations Channel failure link down
1.3.6.1.4.1.3607.2.20.0.2040current
gpeerStateMismatch
NOTIFICATION-TYPE
peer state mismatch
1.3.6.1.4.1.3607.2.20.0.2050current
gproceduralError
NOTIFICATION-TYPE
procedural Error
1.3.6.1.4.1.3607.2.20.0.2060current
gimproperRemoval
NOTIFICATION-TYPE
Improper Removal
1.3.6.1.4.1.3607.2.20.0.2070current
gduplicateNodeID
NOTIFICATION-TYPE
Duplicate Node ID
1.3.6.1.4.1.3607.2.20.0.2080current
gblsrOutOfSync
NOTIFICATION-TYPE
BLSR out of sync
1.3.6.1.4.1.3607.2.20.0.2090current
gblsrMultiNodeTableUpdateCompleted
NOTIFICATION-TYPE
BLSR tables resynchronized
1.3.6.1.4.1.3607.2.20.0.2100current
gprotectionUnitNotAvailable
NOTIFICATION-TYPE
protection unit not available
1.3.6.1.4.1.3607.2.20.0.2110current
gperformanceMonitorThresholdCrossingAlert
NOTIFICATION-TYPE
performance Monitor Threshold Crossing Alert
1.3.6.1.4.1.3607.2.20.0.2120current
gprotectionSwitch
NOTIFICATION-TYPE
occurrence of a protection switching event
1.3.6.1.4.1.3607.2.20.0.2130current
grecoveryOrServiceProtectionActionHasBeenInitiated
NOTIFICATION-TYPE
recovery or service protection action has been initiated
1.3.6.1.4.1.3607.2.20.0.2140current
gautomaticSystemReset
NOTIFICATION-TYPE
automatic system Reset
1.3.6.1.4.1.3607.2.20.0.2150current
gautomaticUPSRSwitchCausedByAIS
NOTIFICATION-TYPE
automatic UPSR switch caused by AIS
1.3.6.1.4.1.3607.2.20.0.2160current
gautomaticUPSRSwitchCausedByLOP
NOTIFICATION-TYPE
automatic UPSR switch caused by Lop
1.3.6.1.4.1.3607.2.20.0.2170current
gautomaticUPSRSwitchCausedByUNEQ
NOTIFICATION-TYPE
automatic UPSR switch caused by Uneq
1.3.6.1.4.1.3607.2.20.0.2180current
gautomaticUPSRSwitchCausedByPDI
NOTIFICATION-TYPE
automatic UPSR switch caused by PDI
1.3.6.1.4.1.3607.2.20.0.2190current
gautomaticUPSRSwitchCausedBySFBER
NOTIFICATION-TYPE
automatic UPSR switch caused by Sfber
1.3.6.1.4.1.3607.2.20.0.2200current
gautomaticUPSRSwitchCausedBySDBER
NOTIFICATION-TYPE
automatic UPSR switch caused by Sdber
1.3.6.1.4.1.3607.2.20.0.2210current
gcoldRestart
NOTIFICATION-TYPE
cold Restart
1.3.6.1.4.1.3607.2.20.0.2220current
gforcedSwitchBackToWorking
NOTIFICATION-TYPE
working facility or eqpt forced switched to working
1.3.6.1.4.1.3607.2.20.0.2230current
gforcedSwitchBackToWorkingRing
NOTIFICATION-TYPE
working facility or eqpt forced switched to working Ring
1.3.6.1.4.1.3607.2.20.0.2240current
gforcedSwitchBackToWorkingSpan
NOTIFICATION-TYPE
working facility or eqpt forced switched to working Span
1.3.6.1.4.1.3607.2.20.0.2250current
gforcedSwitchToProtection
NOTIFICATION-TYPE
working facility or eqpt forced switched protection unit
1.3.6.1.4.1.3607.2.20.0.2260current
gforcedSwitchToProtectionRing
NOTIFICATION-TYPE
working facility or eqpt forced switched protection unit Ring
1.3.6.1.4.1.3607.2.20.0.2270current
gforcedSwitchToProtectionSpan
NOTIFICATION-TYPE
working facility or eqpt forced switched protection unit Span
1.3.6.1.4.1.3607.2.20.0.2280current
gworkingFacilityOrEquipmentForcedToSwitchToProtectionPath
NOTIFICATION-TYPE
working facility or eqpt forced switched protection unit Path
1.3.6.1.4.1.3607.2.20.0.2290current
ginitializationInitiated
NOTIFICATION-TYPE
initialization initiated
1.3.6.1.4.1.3607.2.20.0.2300current
glockoutOfProtection
NOTIFICATION-TYPE
lockout of Protection
1.3.6.1.4.1.3607.2.20.0.2310current
glockoutOfProtectionRing
NOTIFICATION-TYPE
lockout of Protection Ring
1.3.6.1.4.1.3607.2.20.0.2320current
glockoutOfProtectionSpan
NOTIFICATION-TYPE
lockout of Protection Span
1.3.6.1.4.1.3607.2.20.0.2330current
glockoutOfProtectionPath
NOTIFICATION-TYPE
lockout of Protection Path
1.3.6.1.4.1.3607.2.20.0.2340current
glockoutOfWorking
NOTIFICATION-TYPE
lockout of working
1.3.6.1.4.1.3607.2.20.0.2350current
glockoutOfWorkingRing
NOTIFICATION-TYPE
lockout of working Ring
1.3.6.1.4.1.3607.2.20.0.2360current
glockoutOfWorkingSpan
NOTIFICATION-TYPE
lockout of working Span
1.3.6.1.4.1.3607.2.20.0.2370current
gmanualSystemReset
NOTIFICATION-TYPE
manual system Reset
1.3.6.1.4.1.3607.2.20.0.2380current
gmanualSwitchToInternalClock
NOTIFICATION-TYPE
manual switch to internal clock
1.3.6.1.4.1.3607.2.20.0.2390current
gmanualSwitchToPrimaryReference
NOTIFICATION-TYPE
manual Switch To Primary refernce
1.3.6.1.4.1.3607.2.20.0.2400current
gmanualSwitchToSecondReference
NOTIFICATION-TYPE
manual Switch To Second reference
1.3.6.1.4.1.3607.2.20.0.2410current
gmanualSwitchToThirdReference
NOTIFICATION-TYPE
manual Switch To Third refernce
1.3.6.1.4.1.3607.2.20.0.2420current
gmanualSwitchToFourthReference
NOTIFICATION-TYPE
manual Switch To Fourth refernce
1.3.6.1.4.1.3607.2.20.0.2430current
gmanualSwitchToFifthReference
NOTIFICATION-TYPE
manual Switch To Fifth refernce
1.3.6.1.4.1.3607.2.20.0.2440current
gmanualSwitchToSixthReference
NOTIFICATION-TYPE
manual Switch To Sixth refernce
1.3.6.1.4.1.3607.2.20.0.2450current
gmanualSwitchBackToWorking
NOTIFICATION-TYPE
manualSwitch of working facility or eqpt to protection Ring
1.3.6.1.4.1.3607.2.20.0.2460current
gmanualSwitchBackToWorkingRing
NOTIFICATION-TYPE
manualSwitch of working facility or eqpt to protection Span
1.3.6.1.4.1.3607.2.20.0.2470current
gmanualSwitchBackToWorkingSpan
NOTIFICATION-TYPE
manualSwitch of working facility or eqpt to protection
1.3.6.1.4.1.3607.2.20.0.2480current
gmanualSwitchToProtection
NOTIFICATION-TYPE
manualSwitch of Working facility or eqpt to Protection unit
1.3.6.1.4.1.3607.2.20.0.2490current
gmanualSwitchToProtectionRing
NOTIFICATION-TYPE
working facility or eqpt manualSwitch to Protection unit Ring
1.3.6.1.4.1.3607.2.20.0.2500current
gmanualSwitchToProtectionSpan
NOTIFICATION-TYPE
working facility or eqpt manualSwitch to Protection unit Span
1.3.6.1.4.1.3607.2.20.0.2510current
gmanualSwitchOfWorkingFacilityOrEquipmentToProtectionPath
NOTIFICATION-TYPE
manualSwitch of working facility or eqpt to Protection Path
1.3.6.1.4.1.3607.2.20.0.2520current
gpowerfailRestart
NOTIFICATION-TYPE
Powerfail Restart
1.3.6.1.4.1.3607.2.20.0.2530current
gringIsSquelchingTraffic
NOTIFICATION-TYPE
ring is squelching traffic
1.3.6.1.4.1.3607.2.20.0.2540current
gsoftwareDownloadInProgress
NOTIFICATION-TYPE
software download in progress
1.3.6.1.4.1.3607.2.20.0.2550current
gswitchToInternalClock
NOTIFICATION-TYPE
Switch To Internal clock
1.3.6.1.4.1.3607.2.20.0.2560current
gswitchToPrimaryReference
NOTIFICATION-TYPE
Switch To Primary refernce
1.3.6.1.4.1.3607.2.20.0.2570current
gswitchToSecondReference
NOTIFICATION-TYPE
Switch To Second refernce
1.3.6.1.4.1.3607.2.20.0.2580current
gswitchToThirdReference
NOTIFICATION-TYPE
Switch To Third refernce
1.3.6.1.4.1.3607.2.20.0.2590current
gswitchToFourthReference
NOTIFICATION-TYPE
Switch To Fourth refernce
1.3.6.1.4.1.3607.2.20.0.2600current
gswitchToFifthReference
NOTIFICATION-TYPE
Switch To Fifth refernce
1.3.6.1.4.1.3607.2.20.0.2610current
gswitchToSixthReference
NOTIFICATION-TYPE
Switch To Sixth refernce
1.3.6.1.4.1.3607.2.20.0.2620current
gsystemReboot
NOTIFICATION-TYPE
system reboot
1.3.6.1.4.1.3607.2.20.0.2630current
gswitchedBackToWorking
NOTIFICATION-TYPE
Switched Back To Working
1.3.6.1.4.1.3607.2.20.0.2640current
gswitchedToProtection
NOTIFICATION-TYPE
Switched To Protection
1.3.6.1.4.1.3607.2.20.0.2650current
gwarmRestart
NOTIFICATION-TYPE
warm Restart
1.3.6.1.4.1.3607.2.20.0.2660current
gringIsInWaitToRestoreState
NOTIFICATION-TYPE
Ring is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.2670current
gmanualSwitchRequest
NOTIFICATION-TYPE
Manual Switch Request
1.3.6.1.4.1.3607.2.20.0.2680current
gforcedSwitchRequest
NOTIFICATION-TYPE
Forced Switch Request
1.3.6.1.4.1.3607.2.20.0.2690current
glockoutSwitchRequest
NOTIFICATION-TYPE
Lockout Switch Request
1.3.6.1.4.1.3607.2.20.0.2700current
grmonHistoriesAndAlarmsResetReboot
NOTIFICATION-TYPE
RMON histories and alarms have been reset due to chipset reboot
1.3.6.1.4.1.3607.2.20.0.2710current
grmonThresholdCrossingAlarm
NOTIFICATION-TYPE
Crossing of Falling/Rising Threshold detected
1.3.6.1.4.1.3607.2.20.0.2720current
galarmsSuppressedByUserCommand
NOTIFICATION-TYPE
Alarms Suppressed By User Command
1.3.6.1.4.1.3607.2.20.0.2730current
galarmsSuppressedForMaintenance
NOTIFICATION-TYPE
Alarms Suppressed For Maintenance
1.3.6.1.4.1.3607.2.20.0.2740current
gswitchingMatrixModuleFailure
NOTIFICATION-TYPE
Switching Matrix Module Failure
1.3.6.1.4.1.3607.2.20.0.2750current
glanConnectionPolarityReversed
NOTIFICATION-TYPE
Lan Connection Polarity Reversed
1.3.6.1.4.1.3607.2.20.0.2760current
gautonomousPMReportMessageInhibited
NOTIFICATION-TYPE
Autonomous Performance Monitoring Report Message Inhibited
1.3.6.1.4.1.3607.2.20.0.2780current
gioSlotToXCONCommunicationFailure
NOTIFICATION-TYPE
IO Slot To XCON Communication Failure
1.3.6.1.4.1.3607.2.20.0.2790current
gstsPathTraceIdentifierMismatch
NOTIFICATION-TYPE
STS path trace identifier mismatch
1.3.6.1.4.1.3607.2.20.0.2800current
gnePowerFailureAtConnectorA
NOTIFICATION-TYPE
NE power failure at connector A
1.3.6.1.4.1.3607.2.20.0.2810current
gnePowerFailureAtConnectorB
NOTIFICATION-TYPE
NE power failure at connector B
1.3.6.1.4.1.3607.2.20.0.2820current
gfreeMemoryOnCardVeryLow
NOTIFICATION-TYPE
Free memory on the card is very low
1.3.6.1.4.1.3607.2.20.0.2830current
gfreeMemoryOnCardNearZero
NOTIFICATION-TYPE
Free memory on the card is near zero
1.3.6.1.4.1.3607.2.20.0.2840current
gexerciseRequestOnRing
NOTIFICATION-TYPE
Exercise Ring.
1.3.6.1.4.1.3607.2.20.0.2850current
gexerciseRequestOnSpan
NOTIFICATION-TYPE
Exercise Span.
1.3.6.1.4.1.3607.2.20.0.2860current
gsquelchingPath
NOTIFICATION-TYPE
Squelching Path:
1.3.6.1.4.1.3607.2.20.0.2870current
gextraTrafficPreempted
NOTIFICATION-TYPE
Extra Traffic Preempted.
1.3.6.1.4.1.3607.2.20.0.2880current
gfarEndLockoutOfWorkingRing
NOTIFICATION-TYPE
Far End Lockout of working - Ring.
1.3.6.1.4.1.3607.2.20.0.2890current
gfarEndLockoutOfWorkingSpan
NOTIFICATION-TYPE
Far End Lockout of working - Span.
1.3.6.1.4.1.3607.2.20.0.2900current
gfarEndLockoutOfProtectionRing
NOTIFICATION-TYPE
Far End Lockout of Protection - Ring.
1.3.6.1.4.1.3607.2.20.0.2910current
gfarEndLockoutOfProtectionAllSpans
NOTIFICATION-TYPE
Far End Lockout of Protection - All Spans.
1.3.6.1.4.1.3607.2.20.0.2920current
gfarEndWorkingFacilityForcedToSwitchToProtectionRing
NOTIFICATION-TYPE
Far End Working facility forced to switch to protection unit - Ring.
1.3.6.1.4.1.3607.2.20.0.2930current
gfarEndWorkingFacilityForcedToSwitchToProtectionSpan
NOTIFICATION-TYPE
Far End Working facility forced to switch to protection unit - Span.
1.3.6.1.4.1.3607.2.20.0.2940current
gfarEndManualSwitchOfWorkingFacilityToProtectionRing
NOTIFICATION-TYPE
Far End Manual Switch of Working facility to Protection unit - Ring.
1.3.6.1.4.1.3607.2.20.0.2950current
gfarEndManualSwitchOfWorkingFacilityToProtectionSpan
NOTIFICATION-TYPE
Far End Manual Switch of Working facility to Protection unit - Span.
1.3.6.1.4.1.3607.2.20.0.2960current
gfarEndExercisingRing
NOTIFICATION-TYPE
Far End Exercise Ring.
1.3.6.1.4.1.3607.2.20.0.2970current
gfarEndExercisingSpan
NOTIFICATION-TYPE
Far End Exercise Span.
1.3.6.1.4.1.3607.2.20.0.2980current
gfarEndBERThresholdPassedForSignalFailureRing
NOTIFICATION-TYPE
Far End BER threshold passed for Signal Failure - Ring.
1.3.6.1.4.1.3607.2.20.0.2990current
gfarEndBERThresholdPassedForSignalFailureSpan
NOTIFICATION-TYPE
Far End BER threshold passed for Signal Failure - Span.
1.3.6.1.4.1.3607.2.20.0.3000current
gfarEndBERThresholdPassedForSignalDegradeRing
NOTIFICATION-TYPE
Far End BER threshold passed for Signal Degrade - Ring.
1.3.6.1.4.1.3607.2.20.0.3010current
gfarEndBERThresholdPassedForSignalDegradeSpan
NOTIFICATION-TYPE
Far End BER threshold passed for Signal Degrade - Span.
1.3.6.1.4.1.3607.2.20.0.3020current
gapsChannelFarEndProtectionLineSignalDegrade
NOTIFICATION-TYPE
APS Channel - Far End Protection Line Signal Degrade.
1.3.6.1.4.1.3607.2.20.0.3030current
gringSwitchIsActiveOnTheEastSide
NOTIFICATION-TYPE
Ring Switch is active on the East Side.
1.3.6.1.4.1.3607.2.20.0.3040current
gringSwitchIsActiveOnTheWestSide
NOTIFICATION-TYPE
Ring Switch is active on the West Side.
1.3.6.1.4.1.3607.2.20.0.3050current
gspanSwitchIsActiveOnTheEastSide
NOTIFICATION-TYPE
Span Switch is active on the East Side.
1.3.6.1.4.1.3607.2.20.0.3060current
gspanSwitchIsActiveOnTheWestSide
NOTIFICATION-TYPE
Span Switch is active on the West Side.
1.3.6.1.4.1.3607.2.20.0.3070current
guniDirectionalFullPassThroughIsActive
NOTIFICATION-TYPE
Uni-directional Full Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3080current
gbiDirectionalFullPassThroughIsActive
NOTIFICATION-TYPE
Bi-directional Full Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3090current
gkBytesPassThroughIsActive
NOTIFICATION-TYPE
K Bytes Pass Through is active.
1.3.6.1.4.1.3607.2.20.0.3100current
gringIsSegmented
NOTIFICATION-TYPE
Ring is Segmented.
1.3.6.1.4.1.3607.2.20.0.3110current
gringTopologyIsUnderConstruction
NOTIFICATION-TYPE
Ring Topology is under construction.
1.3.6.1.4.1.3607.2.20.0.3120current
glockoutOfProtectionAllSpans
NOTIFICATION-TYPE
Lockout of Protection - All Spans.
1.3.6.1.4.1.3607.2.20.0.3130current
gfarEndOfFiberIsProvisionedWithDifferentRingID
NOTIFICATION-TYPE
Far end of fiber is provisioned with different ring ID
1.3.6.1.4.1.3607.2.20.0.3140current
gbothEndsOfFiberProvisionedAsEastOrBothAsWest
NOTIFICATION-TYPE
Both ends of fiber provisioned as East, or both as West
1.3.6.1.4.1.3607.2.20.0.3150current
gsecurityInvalidLoginUsernameSeeAuditTrail
NOTIFICATION-TYPE
Security: Invalid Login Username - See Audit Trail
1.3.6.1.4.1.3607.2.20.0.3160deprecated
gautonomousMessagesInhibited
NOTIFICATION-TYPE
Autonomous messages inhibited
1.3.6.1.4.1.3607.2.20.0.3170current
gtrafficStormOnLANLANTemporarilyDisabled
NOTIFICATION-TYPE
Traffic storm on LAN. LAN temporarily disabled.
1.3.6.1.4.1.3607.2.20.0.3180current
greptdbchgMessagesInhibited
NOTIFICATION-TYPE
REPT^DBCHG messages of TL1 inhibited
1.3.6.1.4.1.3607.2.20.0.3190current
gsecurityUserIDHasExpired
NOTIFICATION-TYPE
Security: user ID has expired
1.3.6.1.4.1.3607.2.20.0.3200current
gpartialFanFailure
NOTIFICATION-TYPE
Partial Fan Failure
1.3.6.1.4.1.3607.2.20.0.3210current
gforcedSwitchRequestOnRing
NOTIFICATION-TYPE
Force switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3220current
gforcedSwitchRequestOnSpan
NOTIFICATION-TYPE
Force switch request on Span
1.3.6.1.4.1.3607.2.20.0.3230current
glockoutSwitchRequestOnRing
NOTIFICATION-TYPE
Lockout switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3240current
glockoutSwitchRequestOnSpan
NOTIFICATION-TYPE
Lockout switch request on Span
1.3.6.1.4.1.3607.2.20.0.3250current
gmanualSwitchRequestOnRing
NOTIFICATION-TYPE
Manual switch request on Ring
1.3.6.1.4.1.3607.2.20.0.3260current
gmanualSwitchRequestOnSpan
NOTIFICATION-TYPE
Manual switch request on Span
1.3.6.1.4.1.3607.2.20.0.3270current
gcommunicationFailurePeerToPeerSlotControlBusA
NOTIFICATION-TYPE
Peer to Peer Slot communication failure - Control Bus A
1.3.6.1.4.1.3607.2.20.0.3280current
gcommunicationFailurePeerToPeerSlotControlBusB
NOTIFICATION-TYPE
Peer to Peer Slot communication failure - Control Bus B
1.3.6.1.4.1.3607.2.20.0.3290current
gcontrollerAToShelfSlotCommunicationFailure
NOTIFICATION-TYPE
Controller A to shelf slot communication failure
1.3.6.1.4.1.3607.2.20.0.3300current
gcontrollerBToShelfSlotCommunicationFailure
NOTIFICATION-TYPE
Controller B to shelf slot communication failure
1.3.6.1.4.1.3607.2.20.0.3310current
ginterconnectionEquipmentFailureWorkingPayloadBus
NOTIFICATION-TYPE
Interconnection Equipment Failure - Working Payload Bus
1.3.6.1.4.1.3607.2.20.0.3320current
ginterconnectionEquipmentFailureProtectPayloadBus
NOTIFICATION-TYPE
Interconnection Equipment Failure - Protect Payload Bus
1.3.6.1.4.1.3607.2.20.0.3330current
ginhibitSwitchToProtectRequestOnEquipment
NOTIFICATION-TYPE
Inhibit Switch to Protect Request on equipment
1.3.6.1.4.1.3607.2.20.0.3340current
ginhibitSwitchToWorkingRequestOnEquipment
NOTIFICATION-TYPE
Inhibit Switch to Working Request on equipment
1.3.6.1.4.1.3607.2.20.0.3350current
gberThresholdExceededForSignalDegradeLine
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Degrade - Line
1.3.6.1.4.1.3607.2.20.0.3360current
gberThresholdExceededForSignalDegradePath
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Degrade - Path
1.3.6.1.4.1.3607.2.20.0.3370current
gberThresholdExceededForSignalFailureLine
NOTIFICATION-TYPE
BER Threshold Exceeded For Signal Failure - Line
1.3.6.1.4.1.3607.2.20.0.3380current
gberThresholdExceededForSignalFailurePath
NOTIFICATION-TYPE
BER Threshold Exceeded For Signal Failure - Path
1.3.6.1.4.1.3607.2.20.0.3390current
gexercisingRingSuccessfully
NOTIFICATION-TYPE
Exercising Ring Successfully
1.3.6.1.4.1.3607.2.20.0.3400current
gexercisingSpanSuccessfully
NOTIFICATION-TYPE
Exercising Span Successfully
1.3.6.1.4.1.3607.2.20.0.3410current
gspanIsInWaitToRestoreState
NOTIFICATION-TYPE
Span is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.3420current
gexerciseRequestOnRingFailed
NOTIFICATION-TYPE
Exercise Ring Failed
1.3.6.1.4.1.3607.2.20.0.3430current
gexerciseRequestOnSpanFailed
NOTIFICATION-TYPE
Exercise Span Failed
1.3.6.1.4.1.3607.2.20.0.3440current
gfarEndLockoutOfProtectionSpan
NOTIFICATION-TYPE
Far end Lockout of Protection Channel - Span
1.3.6.1.4.1.3607.2.20.0.3450current
gmanufacturingDataMemoryEEPROMFailure
NOTIFICATION-TYPE
Manufacturing EEPROM Failure
1.3.6.1.4.1.3607.2.20.0.3460current
greplaceableEquipmentOrUnitIsMissing
NOTIFICATION-TYPE
Replaceable Equipment/Unit Is Missing
1.3.6.1.4.1.3607.2.20.0.3470current
gsoftwareDownloadFailed
NOTIFICATION-TYPE
Software Download Failed
1.3.6.1.4.1.3607.2.20.0.3480current
gextraTrafficPCADropped
NOTIFICATION-TYPE
Extra Traffic Dropped
1.3.6.1.4.1.3607.2.20.0.3490current
getherTxOversubscribed
NOTIFICATION-TYPE
pkt loss due to oversubscribed xmit
1.3.6.1.4.1.3607.2.20.0.3500current
getherRxOverSubscribed
NOTIFICATION-TYPE
pkt loss due to oversubscribed rcv
1.3.6.1.4.1.3607.2.20.0.3510current
getherTxExcessFlowCtrl
NOTIFICATION-TYPE
excessive ethernet flow ctl xmited
1.3.6.1.4.1.3607.2.20.0.3520current
getherRxExcessFlowCtrl
NOTIFICATION-TYPE
excessive ethernet flow ctl recvd
1.3.6.1.4.1.3607.2.20.0.3530current
gtransportLayerFailure
NOTIFICATION-TYPE
transport layer failure
1.3.6.1.4.1.3607.2.20.0.3540current
getherTxUnderrun
NOTIFICATION-TYPE
Ether hdge internal fifo underrun
1.3.6.1.4.1.3607.2.20.0.3550current
gsynchronizationReferenceFrequencyOutOfBounds
NOTIFICATION-TYPE
Synchronization reference frequency out of bounds.
1.3.6.1.4.1.3607.2.20.0.3560current
gntpOrSntpHostFailure
NOTIFICATION-TYPE
NTP/SNTP Host Failure.
1.3.6.1.4.1.3607.2.20.0.3570current
gpeerCardNotResponding
NOTIFICATION-TYPE
Peer Card Not Responding
1.3.6.1.4.1.3607.2.20.0.3580current
galarmsAndEventsSuppressedForThisObject
NOTIFICATION-TYPE
Alarms and events suppressed for this object
1.3.6.1.4.1.3607.2.20.0.3590current
gds3FrameFormatMismatch
NOTIFICATION-TYPE
DS3 Frame Format Mismatch
1.3.6.1.4.1.3607.2.20.0.3600current
gwaitToRestore
NOTIFICATION-TYPE
Wait To Restore
1.3.6.1.4.1.3607.2.20.0.3610current
gextremeHighVoltBatteryA
NOTIFICATION-TYPE
Extreme High Volt Battery A
1.3.6.1.4.1.3607.2.20.0.3620current
gextremeLowVoltBatteryA
NOTIFICATION-TYPE
Extreme Low Volt Battery A
1.3.6.1.4.1.3607.2.20.0.3630current
gextremeHighVoltBatteryB
NOTIFICATION-TYPE
Extreme High Volt Battery B
1.3.6.1.4.1.3607.2.20.0.3640current
gextremeLowVoltBatteryB
NOTIFICATION-TYPE
Extreme Low Volt Battery B
1.3.6.1.4.1.3607.2.20.0.3650current
giosConfigCopyFailed
NOTIFICATION-TYPE
IOS config copy failed
1.3.6.1.4.1.3607.2.20.0.3660current
giosConfigCopyInProgress
NOTIFICATION-TYPE
IOS config copy in progress
1.3.6.1.4.1.3607.2.20.0.3670current
giosConfigCopySuccess
NOTIFICATION-TYPE
IOS Config Copy Success
1.3.6.1.4.1.3607.2.20.0.3680current
gsignalingUnableToSetupCircuit
NOTIFICATION-TYPE
Signaling Unable to setup circuit
1.3.6.1.4.1.3607.2.20.0.3710current
gerrorInStartupConfig
NOTIFICATION-TYPE
Error in Startup Config
1.3.6.1.4.1.3607.2.20.0.3712current
gnoStartupConfig
NOTIFICATION-TYPE
No Startup Config
1.3.6.1.4.1.3607.2.20.0.3714current
gneedToSaveRunningConfig
NOTIFICATION-TYPE
Need to Save Running Config
1.3.6.1.4.1.3607.2.20.0.3716current
ginvalidAlarm
NOTIFICATION-TYPE
Invalid Alarm
1.3.6.1.4.1.3607.2.20.0.3718current
grsvpHelloFSMToNeighborDown
NOTIFICATION-TYPE
RSVP Hello FSM to Neighbor down
1.3.6.1.4.1.3607.2.20.0.3720current
gsecurityInvalidLoginUsername
NOTIFICATION-TYPE
Security: Invalid Login - Username - See Audit Log
1.3.6.1.4.1.3607.2.20.0.3722current
gdatabaseBackupFailed
NOTIFICATION-TYPE
Database Backup Failed
1.3.6.1.4.1.3607.2.20.0.3724current
gdatabaseRestoreFailed
NOTIFICATION-TYPE
Database Restore Failed
1.3.6.1.4.1.3607.2.20.0.3726current
glmpHelloFSMToControlChannelDown
NOTIFICATION-TYPE
LMP Hello FSM to Control Channel down
1.3.6.1.4.1.3607.2.20.0.3730current
glmpNeighborDiscoveryHasFailed
NOTIFICATION-TYPE
LMP Neighbor Discovery has failed
1.3.6.1.4.1.3607.2.20.0.3740current
gunauthorizedIncomingSignalingRequest
NOTIFICATION-TYPE
Unauthorized incoming signaling request
1.3.6.1.4.1.3607.2.20.0.3750current
gauditLog80PercentFull
NOTIFICATION-TYPE
Audit Log 80 Percent Full
1.3.6.1.4.1.3607.2.20.0.3760current
gmoduleCommunicationFailure
NOTIFICATION-TYPE
Module Communication Failure
1.3.6.1.4.1.3607.2.20.0.3762current
gauditLog100PercentFullOldestRecordsWillBeLost
NOTIFICATION-TYPE
Audit Log 100 Percent Full - Oldest records will be lost
1.3.6.1.4.1.3607.2.20.0.3764current
gstandbyDatabaseOutOfSync
NOTIFICATION-TYPE
Standby Database Out of Sync
1.3.6.1.4.1.3607.2.20.0.3766current
gredundantPowerCapabilityLost
NOTIFICATION-TYPE
Redundant Power Capability Lost
1.3.6.1.4.1.3607.2.20.0.3768current
gforcedSwitchToPrimaryReference
NOTIFICATION-TYPE
Forced Switch To Primary Reference
1.3.6.1.4.1.3607.2.20.0.3770current
gforcedSwitchToSecondReference
NOTIFICATION-TYPE
Forced Switch To Second Reference
1.3.6.1.4.1.3607.2.20.0.3780current
gforcedSwitchToThirdReference
NOTIFICATION-TYPE
Forced Switch To Third Reference
1.3.6.1.4.1.3607.2.20.0.3790current
gforcedSwitchToInternalClock
NOTIFICATION-TYPE
Forced Switch To Internal Clock
1.3.6.1.4.1.3607.2.20.0.3800current
gindustrialHighTemperature
NOTIFICATION-TYPE
Industrial High Temperature
1.3.6.1.4.1.3607.2.20.0.3805current
gimproperMatrixEquipmentInserted
NOTIFICATION-TYPE
Improper matrix equipment inserted
1.3.6.1.4.1.3607.2.20.0.3810current
geqptProblemOnCarrierOrPIM
NOTIFICATION-TYPE
EQPT problem on Carrier or PIM
1.3.6.1.4.1.3607.2.20.0.3820current
geqptProblemOnPIMOrPPM
NOTIFICATION-TYPE
EQPT problem on PIM or PPM
1.3.6.1.4.1.3607.2.20.0.3830current
gtimSectionTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
TIM Section - Trace Identifier Mismatch Failure.
1.3.6.1.4.1.3607.2.20.0.4000current
gaisMultiplexSectionAlarmIndicationSignal
NOTIFICATION-TYPE
SDH Multiplex Section - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4010current
grdiMultiplexSectionRemoteDefectOrAlarmIndication
NOTIFICATION-TYPE
SDH Multiplex Section - Remote Defect Indication.
1.3.6.1.4.1.3607.2.20.0.4020current
gtimHighOrderTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
SDH High Order - Trace Identifier Mismatch.
1.3.6.1.4.1.3607.2.20.0.4030current
gaisAdministrationUnitAlarmIndicationSignal
NOTIFICATION-TYPE
SDH Administration Unit - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4040current
glopAdministrationUnitLossOfPointer
NOTIFICATION-TYPE
SDH Administration Unit - Loss of Pointer.
1.3.6.1.4.1.3607.2.20.0.4050current
gslmfUnequippedHighOrderPathUnequipped
NOTIFICATION-TYPE
SDH SLMF High Order - Unequipped Path.
1.3.6.1.4.1.3607.2.20.0.4060current
gslmfPLMHighOrderPathLabelMismatch
NOTIFICATION-TYPE
SDH SLMF High Order - Path Label Mismatch.
1.3.6.1.4.1.3607.2.20.0.4070current
grdiHighOrderRemoteDefectOrAlarmIndication
NOTIFICATION-TYPE
SDH High Order - Remote Defect Indication.
1.3.6.1.4.1.3607.2.20.0.4080current
glopTributaryUnitLossOfPointer
NOTIFICATION-TYPE
SDH Tributary Unit - Loss of Pointer.
1.3.6.1.4.1.3607.2.20.0.4090current
gaisTributaryUnitAlarmIndicationSignal
NOTIFICATION-TYPE
SDH Tributary Unit - Alarm Indication Signal.
1.3.6.1.4.1.3607.2.20.0.4100current
gslmfUnequippedLowOrderPathUnequipped
NOTIFICATION-TYPE
SDH Low Order - SLMF Unequipped Path.
1.3.6.1.4.1.3607.2.20.0.4110current
gslmfPLMLowOrderPathLabelMismatch
NOTIFICATION-TYPE
SDH Low Order - SLMF Path Label Mismatch.
1.3.6.1.4.1.3607.2.20.0.4120current
gtimLowOrderTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
SDH Low Order - Trace Identifier Mismatch.
1.3.6.1.4.1.3607.2.20.0.4130current
grfiLowOrderRemoteFailureOrAlarmIndication
NOTIFICATION-TYPE
SDH Low Order - Remote Failure Indication.
1.3.6.1.4.1.3607.2.20.0.4140current
gg811PrimaryReferenceClockTraceable
NOTIFICATION-TYPE
G811 - Primary Reference Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4150current
gg812TransitNodeClockTraceable
NOTIFICATION-TYPE
G812 - Transit Node Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4160current
gg812LocalNodeClockTraceable
NOTIFICATION-TYPE
G812 - Local Node Clock traceable.
1.3.6.1.4.1.3607.2.20.0.4170current
gg813SynchronousEquipmentTimingSourceTraceable
NOTIFICATION-TYPE
G813 - Synchronous Equipment Timing Source traceable.
1.3.6.1.4.1.3607.2.20.0.4180current
ge1LoopbackDueToFEACCommand
NOTIFICATION-TYPE
loopback due to FEAC Command E1
1.3.6.1.4.1.3607.2.20.0.4190current
ge1LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
loopback Command sent to Far End E1
1.3.6.1.4.1.3607.2.20.0.4200current
ge3LoopbackDueToFEACCommand
NOTIFICATION-TYPE
loopback due to FEAC Command E3
1.3.6.1.4.1.3607.2.20.0.4210current
gfarEndMultipleE1LOSDetectedOnE3
NOTIFICATION-TYPE
far end Multiple E1 LOS detected on E3
1.3.6.1.4.1.3607.2.20.0.4220current
gfarEndE1EqptFailNonServiceAffecting
NOTIFICATION-TYPE
far end E1 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.4230current
gfarEndE1EqptFailServiceAffecting
NOTIFICATION-TYPE
far end E1 eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.4240current
gfarEndSingleE1LOS
NOTIFICATION-TYPE
far end Single E1 LOS
1.3.6.1.4.1.3607.2.20.0.4250current
gfarEndE3EqptFailServiceAffecting
NOTIFICATION-TYPE
far end E3 eqpt fail service affecting
1.3.6.1.4.1.3607.2.20.0.4260current
ge3LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
loopback Command sent to Far End E3
1.3.6.1.4.1.3607.2.20.0.4270current
gfarEndE3EqptFailNonServiceAffecting
NOTIFICATION-TYPE
far end E3 eqpt fail non service affecting
1.3.6.1.4.1.3607.2.20.0.4280current
glowVoltBatteryA
NOTIFICATION-TYPE
Low Volt - Battery A
1.3.6.1.4.1.3607.2.20.0.4290current
ghighVoltBatteryA
NOTIFICATION-TYPE
High Volt - Battery A
1.3.6.1.4.1.3607.2.20.0.4300current
glowVoltBatteryB
NOTIFICATION-TYPE
Low Volt - Battery B
1.3.6.1.4.1.3607.2.20.0.4310current
ghighVoltBatteryB
NOTIFICATION-TYPE
High Volt - Battery B
1.3.6.1.4.1.3607.2.20.0.4320current
gmsspRingOutOfSync
NOTIFICATION-TYPE
MS-SP ring out of sync
1.3.6.1.4.1.3607.2.20.0.4330current
gmsspMultiNodeTableUpdateCompleted
NOTIFICATION-TYPE
MS-SP ring tables resynchronized
1.3.6.1.4.1.3607.2.20.0.4340current
gautomaticSNCPSwitchCausedByAIS
NOTIFICATION-TYPE
automatic SNCP switch caused by AIS
1.3.6.1.4.1.3607.2.20.0.4350current
gautomaticSNCPSwitchCausedByLOP
NOTIFICATION-TYPE
automatic SNCP switch caused by Lop
1.3.6.1.4.1.3607.2.20.0.4360current
gautomaticSNCPSwitchCausedByUNEQ
NOTIFICATION-TYPE
automatic SNCP switch caused by Uneq
1.3.6.1.4.1.3607.2.20.0.4370current
gautomaticSNCPSwitchCausedByPDI
NOTIFICATION-TYPE
automatic SNCP switch caused by PDI
1.3.6.1.4.1.3607.2.20.0.4380current
gautomaticSNCPSwitchCausedBySFBER
NOTIFICATION-TYPE
automatic SNCP switch caused by Sfber
1.3.6.1.4.1.3607.2.20.0.4390current
gautomaticSNCPSwitchCausedBySDBER
NOTIFICATION-TYPE
automatic SNCP switch caused by Sdber
1.3.6.1.4.1.3607.2.20.0.4400current
gstmConcatenationError
NOTIFICATION-TYPE
concatenation error STM
1.3.6.1.4.1.3607.2.20.0.4410current
ge3IdleCondition
NOTIFICATION-TYPE
idle Condition E3
1.3.6.1.4.1.3607.2.20.0.4420current
gchannelMSSPInconsistentAPSCode
NOTIFICATION-TYPE
channel MSSP inconsistent APS code
1.3.6.1.4.1.3607.2.20.0.4430current
gchannelMSSPImproperAPSCodeAPS
NOTIFICATION-TYPE
channel MSSP Improper APS code APS
1.3.6.1.4.1.3607.2.20.0.4440current
gchannelMSSPNodeIdMismatchAPS
NOTIFICATION-TYPE
channel MSSP Node Id Mismatch APS
1.3.6.1.4.1.3607.2.20.0.4450current
gchannelMSSPDefaultKAPS
NOTIFICATION-TYPE
channel MSSP Default K APS
1.3.6.1.4.1.3607.2.20.0.4460current
gchannelMSSPConnectionLossAPS
NOTIFICATION-TYPE
channel MSSP Connection loss APS
1.3.6.1.4.1.3607.2.20.0.4470current
gminimumClockTraceableSDH
NOTIFICATION-TYPE
SDH Minimum clock Traceable
1.3.6.1.4.1.3607.2.20.0.4480current
glineIsInWaitToRestoreStateSDH
NOTIFICATION-TYPE
SDH line is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.4490current
gberThresholdExceededForSignalDegradeHighOrder
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Degrade - High Order
1.3.6.1.4.1.3607.2.20.0.4500current
gberThresholdExceededForSignalFailureHighOrder
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Failure - High Order
1.3.6.1.4.1.3607.2.20.0.4510current
gberThresholdExceededForSignalDegradeLowOrder
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Degrade - Low Order
1.3.6.1.4.1.3607.2.20.0.4520current
gberThresholdExceededForSignalFailureLowOrder
NOTIFICATION-TYPE
BER Threshold exceeded for Signal Failure - Low Order
1.3.6.1.4.1.3607.2.20.0.4530current
gfailureToSwitchToProtectionHighOrderPath
NOTIFICATION-TYPE
Failure To Switch To Protection - High Order Path
1.3.6.1.4.1.3607.2.20.0.4540current
gfailureToSwitchToProtectionLowOrderPath
NOTIFICATION-TYPE
Failure To Switch To Protection - Low Order Path
1.3.6.1.4.1.3607.2.20.0.4550current
glofAdministrationUnitLossOfMultiFrame
NOTIFICATION-TYPE
SDH Administration Unit Loss of Multiframe.
1.3.6.1.4.1.3607.2.20.0.4560current
gsdhSpanIsInWaitToRestoreState
NOTIFICATION-TYPE
SDH span is in Wait To Restore state
1.3.6.1.4.1.3607.2.20.0.4570current
ga8b10bOutOfSync
NOTIFICATION-TYPE
8B10B Out of Sync
1.3.6.1.4.1.3607.2.20.0.4755current
godukPMAlarmIndicationSignal
NOTIFICATION-TYPE
ODUk: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.4760current
gotukAlarmIndicationSignal
NOTIFICATION-TYPE
OTUk: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.4765current
gotukSMBackwardDefectIndication
NOTIFICATION-TYPE
OTUk: Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4770current
gfecUncorrectedWord
NOTIFICATION-TYPE
FEC Uncorrected Word
1.3.6.1.4.1.3607.2.20.0.4780current
ggccTerminationFailure
NOTIFICATION-TYPE
GCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.4785current
gotukIncomingAlignmentError
NOTIFICATION-TYPE
OTUk: Incoming Alignment Error
1.3.6.1.4.1.3607.2.20.0.4790current
godukLockedDefectPM
NOTIFICATION-TYPE
ODUk: Locked Defect PM
1.3.6.1.4.1.3607.2.20.0.4795current
glossOfMultiFrame
NOTIFICATION-TYPE
Loss of Multi-Frame
1.3.6.1.4.1.3607.2.20.0.4800current
godukOpenConnectionIndication
NOTIFICATION-TYPE
ODUk: Open Connection Indication
1.3.6.1.4.1.3607.2.20.0.4805current
gpayloadTypeIdentifierMismatch
NOTIFICATION-TYPE
Payload Type Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4810current
godukTrailTraceIdentifierMismatch
NOTIFICATION-TYPE
ODUk: Trail Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4815current
gotukTrailTraceIdentifierMismatch
NOTIFICATION-TYPE
OTUk: Trail Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.4820current
gequipmentHighLaserBias
NOTIFICATION-TYPE
Equipment High Laser Bias
1.3.6.1.4.1.3607.2.20.0.4825current
gequipmentHighLaserTemp
NOTIFICATION-TYPE
Equipment High Laser Temp
1.3.6.1.4.1.3607.2.20.0.4830current
gequipmentHighLaserPeltier
NOTIFICATION-TYPE
Equipment High Laser Peltier
1.3.6.1.4.1.3607.2.20.0.4835current
gfacilityHighRxPower
NOTIFICATION-TYPE
Facility High Rx power
1.3.6.1.4.1.3607.2.20.0.4840current
gequipmentHighTxPower
NOTIFICATION-TYPE
Equipment High Tx power
1.3.6.1.4.1.3607.2.20.0.4845current
gequipmentHighTransceiverVoltage
NOTIFICATION-TYPE
Equipment High Transceiver voltage
1.3.6.1.4.1.3607.2.20.0.4850current
gequipmentLowLaserBias
NOTIFICATION-TYPE
Equipment Low Laser Bias
1.3.6.1.4.1.3607.2.20.0.4855current
gequipmentLowLaserTemp
NOTIFICATION-TYPE
Equipment Low Laser Temp
1.3.6.1.4.1.3607.2.20.0.4860current
gequipmentLowLaserPeltier
NOTIFICATION-TYPE
Equipment Low Laser Peltier
1.3.6.1.4.1.3607.2.20.0.4865current
gfacilityLowRxPower
NOTIFICATION-TYPE
Facility Low Rx power
1.3.6.1.4.1.3607.2.20.0.4870current
gequipmentLowTxPower
NOTIFICATION-TYPE
Equipment Low Tx power
1.3.6.1.4.1.3607.2.20.0.4875current
gequipmentLowTransceiverVoltage
NOTIFICATION-TYPE
Equipment Low Transceiver voltage
1.3.6.1.4.1.3607.2.20.0.4880current
gequipmentRxLocked
NOTIFICATION-TYPE
Equipment Rx Locked
1.3.6.1.4.1.3607.2.20.0.4885current
gequipmentSquelched
NOTIFICATION-TYPE
Equipment Squelched
1.3.6.1.4.1.3607.2.20.0.4890current
gequipmentTxLocked
NOTIFICATION-TYPE
Equipment Tx Locked
1.3.6.1.4.1.3607.2.20.0.4895current
gotukSignalFailure
NOTIFICATION-TYPE
OTUK Signal Failure
1.3.6.1.4.1.3607.2.20.0.4900current
godukSignalFailure
NOTIFICATION-TYPE
ODUK Signal Failure
1.3.6.1.4.1.3607.2.20.0.4905current
gotukSignalDegrade
NOTIFICATION-TYPE
OTUK Signal Degrade
1.3.6.1.4.1.3607.2.20.0.4910current
godukSignalDegrade
NOTIFICATION-TYPE
ODUK Signal Degrade
1.3.6.1.4.1.3607.2.20.0.4915current
gpluggablePortMissing
NOTIFICATION-TYPE
Pluggable Port missing
1.3.6.1.4.1.3607.2.20.0.4920current
gpluggablePortRateMismatch
NOTIFICATION-TYPE
Pluggable Port rate mismatch
1.3.6.1.4.1.3607.2.20.0.4925current
gpluggablePortSecurityCodeMismatch
NOTIFICATION-TYPE
Pluggable Port security code mismatch
1.3.6.1.4.1.3607.2.20.0.4930current
gtciNotSelected
NOTIFICATION-TYPE
Tci not selected
1.3.6.1.4.1.3607.2.20.0.4935current
gtci1ClockFailure
NOTIFICATION-TYPE
Tci 1 Clock Failure
1.3.6.1.4.1.3607.2.20.0.4940current
godukPMBackwardDefectIndication
NOTIFICATION-TYPE
ODUk: PM Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4945current
godukTCM1BackwardDefectIndication
NOTIFICATION-TYPE
ODUk: TCM1 Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4950current
godukTCM2BackwardDefectIndication
NOTIFICATION-TYPE
ODUk: TCM2 Backward Defect Indication
1.3.6.1.4.1.3607.2.20.0.4955current
gequipmentHighRxTemperature
NOTIFICATION-TYPE
Equipment High Rx temperature
1.3.6.1.4.1.3607.2.20.0.4960current
gequipmentLowRxTemperature
NOTIFICATION-TYPE
Equipment Low Rx temperature
1.3.6.1.4.1.3607.2.20.0.4965current
gtci2ClockFailure
NOTIFICATION-TYPE
Tci 2 Clock Failure
1.3.6.1.4.1.3607.2.20.0.4970current
gequipmentWavelengthMismatch
NOTIFICATION-TYPE
Equipment Wavelength Mismatch
1.3.6.1.4.1.3607.2.20.0.4975current
gdspCommunicationFailure
NOTIFICATION-TYPE
DSP Communication Failure
1.3.6.1.4.1.3607.2.20.0.4980current
gdspFailure
NOTIFICATION-TYPE
DSP Failure
1.3.6.1.4.1.3607.2.20.0.4985current
glaserApproachingEndOfLife
NOTIFICATION-TYPE
Laser Approaching End of Life
1.3.6.1.4.1.3607.2.20.0.5000current
gcrossconnectLoopback
NOTIFICATION-TYPE
Cross-connect Loopback
1.3.6.1.4.1.3607.2.20.0.5010current
gadminLogoutOfUser
NOTIFICATION-TYPE
Admin Logout of User
1.3.6.1.4.1.3607.2.20.0.5020current
guserLockedOut
NOTIFICATION-TYPE
User Locked Out
1.3.6.1.4.1.3607.2.20.0.5030current
gadminLockoutOfUser
NOTIFICATION-TYPE
Admin Lockout of User
1.3.6.1.4.1.3607.2.20.0.5040current
gadminLockoutClear
NOTIFICATION-TYPE
Admin Lockout Clear
1.3.6.1.4.1.3607.2.20.0.5050current
ginvalidLoginUsername
NOTIFICATION-TYPE
Invalid Login: Username
1.3.6.1.4.1.3607.2.20.0.5060current
gsecurityInvalidLoginPassword
NOTIFICATION-TYPE
Invalid Login: Password
1.3.6.1.4.1.3607.2.20.0.5070current
gsecurityInvalidLoginLockedOut
NOTIFICATION-TYPE
Invalid Login: Locked Out
1.3.6.1.4.1.3607.2.20.0.5080current
gsecurityInvalidLoginAlreadyLoggedOn
NOTIFICATION-TYPE
Invalid Login: Already Logged On
1.3.6.1.4.1.3607.2.20.0.5090current
gloginOfUser
NOTIFICATION-TYPE
Login of User
1.3.6.1.4.1.3607.2.20.0.5100current
gautomaticLogoutOfIdleUser
NOTIFICATION-TYPE
Automatic Logout of IdleUser
1.3.6.1.4.1.3607.2.20.0.5110current
glogoutOfUser
NOTIFICATION-TYPE
Logout of User
1.3.6.1.4.1.3607.2.20.0.5120current
genhancedRemoteFailureIndicationPathServer
NOTIFICATION-TYPE
Enhanced Remote Failure Indication - Path - Server
1.3.6.1.4.1.3607.2.20.0.5200current
genhancedRemoteFailureIndicationPathConnectivity
NOTIFICATION-TYPE
Enhanced Remote Failure Indication - Path - Connectivity
1.3.6.1.4.1.3607.2.20.0.5210current
genhancedRemoteFailureIndicationPathPayload
NOTIFICATION-TYPE
Enhanced Remote Failure Indication - Path - Payload
1.3.6.1.4.1.3607.2.20.0.5220current
gfirewallHasBeenDisabled
NOTIFICATION-TYPE
Firewall Has Been Disabled
1.3.6.1.4.1.3607.2.20.0.5230current
gsecurityIntrusionDetPwd
NOTIFICATION-TYPE
Security Intrusion - Incorrect Password
1.3.6.1.4.1.3607.2.20.0.5240current
gsecurityIntrusionDetUser
NOTIFICATION-TYPE
Security Intrusion - Incorrect Username
1.3.6.1.4.1.3607.2.20.0.5250current
gconnectionEquipmentMismatch
NOTIFICATION-TYPE
Connection Equipment Mismatch
1.3.6.1.4.1.3607.2.20.0.5260current
gdisableInactiveUser
NOTIFICATION-TYPE
Disable Inactive User
1.3.6.1.4.1.3607.2.20.0.5270current
gdisableInactiveClear
NOTIFICATION-TYPE
Disable Inactive Clear
1.3.6.1.4.1.3607.2.20.0.5280current
gbatteryFailure
NOTIFICATION-TYPE
Battery Failure
1.3.6.1.4.1.3607.2.20.0.5290current
gextremeHighVolt
NOTIFICATION-TYPE
Extreme High Volt
1.3.6.1.4.1.3607.2.20.0.5300current
gextremeLowVolt
NOTIFICATION-TYPE
Extreme Low Volt
1.3.6.1.4.1.3607.2.20.0.5310current
ghighVolt
NOTIFICATION-TYPE
High Volt
1.3.6.1.4.1.3607.2.20.0.5320current
glowVolt
NOTIFICATION-TYPE
Low Volt
1.3.6.1.4.1.3607.2.20.0.5330current
gsuspendUser
NOTIFICATION-TYPE
Suspend User
1.3.6.1.4.1.3607.2.20.0.5340current
gsuspendUserClear
NOTIFICATION-TYPE
Suspend User Clear
1.3.6.1.4.1.3607.2.20.0.5350current
glineDccTerminationFailure
NOTIFICATION-TYPE
Line DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.5360current
gmultiplexSectionDccTerminationFailure
NOTIFICATION-TYPE
Multiplex Section DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.5370current
ggigaBitEthernetOutOfSync
NOTIFICATION-TYPE
GigaBit Ethernet Out of Sync
1.3.6.1.4.1.3607.2.20.0.5380current
gsequenceMismatch
NOTIFICATION-TYPE
Sequence Mismatch
1.3.6.1.4.1.3607.2.20.0.5390current
glossOfAlignment
NOTIFICATION-TYPE
Loss of Alignment
1.3.6.1.4.1.3607.2.20.0.5400current
goutOfUseByAdministrativeCommand
NOTIFICATION-TYPE
Out of Use - Administrative Command
1.3.6.1.4.1.3607.2.20.0.5410current
goutOfUseTransportFailure
NOTIFICATION-TYPE
Out of Use - Transport Failure
1.3.6.1.4.1.3607.2.20.0.5420current
gvcatGroupDown
NOTIFICATION-TYPE
VCAT Group Down
1.3.6.1.4.1.3607.2.20.0.5430current
gvcatGroupDegraded
NOTIFICATION-TYPE
VCAT Group Degraded
1.3.6.1.4.1.3607.2.20.0.5440current
gvcatGroupIncomplete
NOTIFICATION-TYPE
VCAT Group Incomplete
1.3.6.1.4.1.3607.2.20.0.5450current
galarmIndicationSignalInTX
NOTIFICATION-TYPE
Alarm Indication Signal in TX
1.3.6.1.4.1.3607.2.20.0.5460current
gremoteAlarmIndicationInTX
NOTIFICATION-TYPE
Remote Alarm Indication in TX
1.3.6.1.4.1.3607.2.20.0.5470current
gkByteAPSChannelFailure
NOTIFICATION-TYPE
Kbyte Channel Failure
1.3.6.1.4.1.3607.2.20.0.5480current
gapsInvalidMode
NOTIFICATION-TYPE
APS Invalid Mode
1.3.6.1.4.1.3607.2.20.0.5490current
gipAddressAlreadyInUseWithinTheSameDccArea
NOTIFICATION-TYPE
IP address already in use within the same DCC Area
1.3.6.1.4.1.3607.2.20.0.5500current
gnodeNameInUseWithinTheSameDccArea
NOTIFICATION-TYPE
Node name already in use within the same DCC Area
1.3.6.1.4.1.3607.2.20.0.5510current
grearPanelEthernetLinkRemoved
NOTIFICATION-TYPE
Rear Panel Ethernet Link Removed
1.3.6.1.4.1.3607.2.20.0.5520current
gmanualSwitchToProtectResultedInNoTrafficSwitch
NOTIFICATION-TYPE
Manual Switch To Protect Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5530current
gmanualSwitchBackToWorkingResultedInNoTrafficSwitch
NOTIFICATION-TYPE
Manual Switch Back To Working Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5540current
gforcedSwitchToProtectResultedInNoTrafficSwitch
NOTIFICATION-TYPE
Forced Switch To Protection Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5550current
gforcedSwitchBackToWorkingResultedInNoTrafficSwitch
NOTIFICATION-TYPE
Forced Switch Back To Working Resulted in No Traffic Switch
1.3.6.1.4.1.3607.2.20.0.5560current
gduplicateSerialNumberDetectedOnAPluggableEntity
NOTIFICATION-TYPE
Duplicate Serial number detected on a pluggable entity
1.3.6.1.4.1.3607.2.20.0.5570current
glossOfSignalForOpticalChannel
NOTIFICATION-TYPE
Incoming Payload Signal Absent
1.3.6.1.4.1.3607.2.20.0.5600current
gencapsulationMismatchPath
NOTIFICATION-TYPE
Encapsulation Type Mismatch
1.3.6.1.4.1.3607.2.20.0.5610current
gencapsulationMismatchVT
NOTIFICATION-TYPE
Encapsulation Mismatch - VT
1.3.6.1.4.1.3607.2.20.0.5620current
gencapsulationMismatchHighOrderPath
NOTIFICATION-TYPE
Encapsulation Mismatch High Order - Path
1.3.6.1.4.1.3607.2.20.0.5630current
gencapsulationMismatchLowOrderPath
NOTIFICATION-TYPE
Encapsulation Mismatch Low Order - Path
1.3.6.1.4.1.3607.2.20.0.5640current
ggfpUserPayloadMismatch
NOTIFICATION-TYPE
GFP User Payload Mismatch
1.3.6.1.4.1.3607.2.20.0.5650current
ggfpFibreChannelDistanceExtensionMismatch
NOTIFICATION-TYPE
GFP Fibre Channel Distance Extension Mismatch
1.3.6.1.4.1.3607.2.20.0.5660current
ggfpFibreChannelDistanceExtensionBufferStarvation
NOTIFICATION-TYPE
GFP Fibre Channel Distance Extension Buffer Starvation
1.3.6.1.4.1.3607.2.20.0.5670current
ggfpFibreChannelDistanceExtensionCreditStarvation
NOTIFICATION-TYPE
Fibre Channel Distance Extension Credit Starvation
1.3.6.1.4.1.3607.2.20.0.5680current
gautomaticWdmAnsFinished
NOTIFICATION-TYPE
Automatic WDM ANS Finished
1.3.6.1.4.1.3607.2.20.0.5690current
ggfpClientSignalFailDetected
NOTIFICATION-TYPE
GFP Client Signal Fail Detected
1.3.6.1.4.1.3607.2.20.0.5700current
ggfpLossOfFrameDelineation
NOTIFICATION-TYPE
GFP Loss of Frame Delineation
1.3.6.1.4.1.3607.2.20.0.5710current
ggfpExtensionHeaderMismatch
NOTIFICATION-TYPE
GFP Extension Header Mismatch
1.3.6.1.4.1.3607.2.20.0.5730current
gincomingOverheadSignalAbsent
NOTIFICATION-TYPE
Loss of Signal for Overhead
1.3.6.1.4.1.3607.2.20.0.5740current
gopticalSafetyRemoteInterlockOn
NOTIFICATION-TYPE
Optical Safety Remote Interlock On
1.3.6.1.4.1.3607.2.20.0.5750current
gautomaticPowerControlCorrectionSkipped
NOTIFICATION-TYPE
Automatic Power Control Correction Skipped
1.3.6.1.4.1.3607.2.20.0.5770current
gapcCannotSetValueDueToRangeLimits
NOTIFICATION-TYPE
APC cannot set value due to range limits
1.3.6.1.4.1.3607.2.20.0.5780current
glcasVcgMemberTxSideInAddState
NOTIFICATION-TYPE
LCAS VCG Member Tx Side In ADD State
1.3.6.1.4.1.3607.2.20.0.5790current
gfarEndManualSwitchBackToWorkingSpan
NOTIFICATION-TYPE
Far End Manual Switch Back to Working - Span
1.3.6.1.4.1.3607.2.20.0.5800current
gfarEndForcedSwitchBackToWorkingSpan
NOTIFICATION-TYPE
Far End Forced Switch Back to Working - Span
1.3.6.1.4.1.3607.2.20.0.5810current
guniversalTransponderModuleHardwareFailure
NOTIFICATION-TYPE
Universal Transponder Module Hardware Failure
1.3.6.1.4.1.3607.2.20.0.5820current
guniversalTransponderModuleCommunicationFailure
NOTIFICATION-TYPE
Universal Transponder Module Communication Failure
1.3.6.1.4.1.3607.2.20.0.5830current
gpluginModuleRangeSettingsMismatch
NOTIFICATION-TYPE
Plug-in Module Range Settings Mismatch
1.3.6.1.4.1.3607.2.20.0.5840current
glcasVcgMemberTxSideInDnuState
NOTIFICATION-TYPE
LCAS VCG Member Tx Side In DNU State
1.3.6.1.4.1.3607.2.20.0.5850current
glcasControlWordCrcCheckFailure
NOTIFICATION-TYPE
LCAS Control Word CRC Check Failure
1.3.6.1.4.1.3607.2.20.0.5860current
glcasVcgMemberRxSideInFailState
NOTIFICATION-TYPE
LCAS VCG Member Rx Side In FAIL State
1.3.6.1.4.1.3607.2.20.0.5870current
gsignalLossOnDataInterface
NOTIFICATION-TYPE
Signal Loss on Data Interface
1.3.6.1.4.1.3607.2.20.0.5880current
gsynchronizationLossOnDataInterface
NOTIFICATION-TYPE
Synchronization Loss on Data Interface
1.3.6.1.4.1.3607.2.20.0.5890current
gportFAIL
NOTIFICATION-TYPE
PORT FAIL
1.3.6.1.4.1.3607.2.20.0.5900current
gunreachablePortTargetPower
NOTIFICATION-TYPE
Unreachable port target power
1.3.6.1.4.1.3607.2.20.0.5910current
gportAddPowerDegradeLow
NOTIFICATION-TYPE
Port Add Power Degrade Low
1.3.6.1.4.1.3607.2.20.0.5920current
gportAddPowerDegradeHigh
NOTIFICATION-TYPE
Port Add Power Degrade High
1.3.6.1.4.1.3607.2.20.0.5930current
gportAddPowerFailLow
NOTIFICATION-TYPE
Port Add Power Fail Low
1.3.6.1.4.1.3607.2.20.0.5940current
gportAddPowerFailHigh
NOTIFICATION-TYPE
Port Add Power Fail High
1.3.6.1.4.1.3607.2.20.0.5950current
gautomaticPowerControlTerminatedOnManualRequest
NOTIFICATION-TYPE
Automatic Power Control Terminated on Manual request
1.3.6.1.4.1.3607.2.20.0.6000current
goduk1AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk-1: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6010current
goduk2AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk-2: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6020current
goduk3AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk-3: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6030current
goduk4AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk-4: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.6040current
gtemperatureReadingMismatchBetweenSCCards
NOTIFICATION-TYPE
Temperature Reading Mismatch Between SC Cards
1.3.6.1.4.1.3607.2.20.0.6050current
gvoltageReadingMismatchBetweenSCCards
NOTIFICATION-TYPE
Voltage Reading Mismatch Between SC Cards
1.3.6.1.4.1.3607.2.20.0.6060current
galarmsSuppressedonOutOfGroupVcatMember
NOTIFICATION-TYPE
Alarms Suppressed on Out-Of-Group VCAT Member
1.3.6.1.4.1.3607.2.20.0.6070current
gblsrSoftwareVersionMismatch
NOTIFICATION-TYPE
BLSR Software Version Mismatch
1.3.6.1.4.1.3607.2.20.0.6080current
goptimized1Plus1ApsPrimaryFacility
NOTIFICATION-TYPE
Optimized 1+1 APS Primary Facility
1.3.6.1.4.1.3607.2.20.0.6090current
goptimized1Plus1ApsPrimarySectionMismatch
NOTIFICATION-TYPE
Optimized 1+1 APS Primary Section Mismatch
1.3.6.1.4.1.3607.2.20.0.6100current
goptimized1Plus1ApsInvalidPrimarySection
NOTIFICATION-TYPE
Optimized 1+1 APS Invalid Primary Section
1.3.6.1.4.1.3607.2.20.0.6110current
gcompositeClockHighLineVoltage
NOTIFICATION-TYPE
Composite Clock High Line Voltage
1.3.6.1.4.1.3607.2.20.0.6120current
gberThresholdExceededForSignalDegradeVt
NOTIFICATION-TYPE
BER Threshold Exceeded For Signal Degrade - VT
1.3.6.1.4.1.3607.2.20.0.6130current
gberThresholdExceededForSignalFailureVt
NOTIFICATION-TYPE
BER Threshold Exceeded For Signal Failure - VT
1.3.6.1.4.1.3607.2.20.0.6140current
gspanLengthOutOfRange
NOTIFICATION-TYPE
Span Length Out of Range
1.3.6.1.4.1.3607.2.20.0.6150current
gidleSignalCondition
NOTIFICATION-TYPE
Idle Signal Condition
1.3.6.1.4.1.3607.2.20.0.6170current
gidleSignalConditionInTx
NOTIFICATION-TYPE
Idle Signal Condition in TX
1.3.6.1.4.1.3607.2.20.0.6180current
gvtPathTraceIdentifierMismatch
NOTIFICATION-TYPE
VT Path Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6190current
glossOfFrameInTX
NOTIFICATION-TYPE
Loss of Frame in TX
1.3.6.1.4.1.3607.2.20.0.6200current
gprovisioningMismatch
NOTIFICATION-TYPE
Provisioning Mismatch
1.3.6.1.4.1.3607.2.20.0.6210current
gsectionTraceIdentifierMismatch
NOTIFICATION-TYPE
Section Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6220current
gregeneratorSectionTraceIdentifierMismatch
NOTIFICATION-TYPE
Regenerator Section Trace Identifier Mismatch
1.3.6.1.4.1.3607.2.20.0.6230current
gswitchingMatrixModuleFailureWorking
NOTIFICATION-TYPE
Switching Matrix Module Failure - Working
1.3.6.1.4.1.3607.2.20.0.6240current
gswitchingMatrixModuleFailureProtect
NOTIFICATION-TYPE
Switching Matrix Module Failure - Protect
1.3.6.1.4.1.3607.2.20.0.6250current
gslotCommunicationDisabled
NOTIFICATION-TYPE
Slot Communication Disabled
1.3.6.1.4.1.3607.2.20.0.6260current
gsessionTimeLimitExpired
NOTIFICATION-TYPE
Session Time Limit Expired
1.3.6.1.4.1.3607.2.20.0.6270current
guserPasswordChangeRequired
NOTIFICATION-TYPE
User Password Change Required
1.3.6.1.4.1.3607.2.20.0.6280current
gisisAdjacencyFailure
NOTIFICATION-TYPE
ISIS Adjacency Failure
1.3.6.1.4.1.3607.2.20.0.6290current
gmsspSoftwareVersionMismatch
NOTIFICATION-TYPE
MSSP Software Version Mismatch
1.3.6.1.4.1.3607.2.20.0.6300current
gremoteAuthenticationFailSeeAuditLog
NOTIFICATION-TYPE
Remote Authentication Fail - See Audit Log
1.3.6.1.4.1.3607.2.20.0.6310current
gillegalRouteAdditionToNetwork
NOTIFICATION-TYPE
Illegal route addition to the Network
1.3.6.1.4.1.3607.2.20.0.6320current
gringIsSquelchingStsTraffic
NOTIFICATION-TYPE
Ring Is Squelching STS Traffic
1.3.6.1.4.1.3607.2.20.0.6330current
gringIsSquelchingVtTraffic
NOTIFICATION-TYPE
Ring Is Squelching VT Traffic
1.3.6.1.4.1.3607.2.20.0.6340current
garchiveOfAuditLogFailed
NOTIFICATION-TYPE
Archival of Audit Log Failed
1.3.6.1.4.1.3607.2.20.0.6350current
grprWrapped
NOTIFICATION-TYPE
RPR Wrapped
1.3.6.1.4.1.3607.2.20.0.6360current
gshelfCommunicationFailure
NOTIFICATION-TYPE
Shelf Communication Failure
1.3.6.1.4.1.3607.2.20.0.6370current
gduplicatedShelfIdentifier
NOTIFICATION-TYPE
Duplicated Shelf Identifier
1.3.6.1.4.1.3607.2.20.0.6380current
gsoftwareMismatch
NOTIFICATION-TYPE
Software Mismatch
1.3.6.1.4.1.3607.2.20.0.6390current
glmpFailure
NOTIFICATION-TYPE
LMP Failure
1.3.6.1.4.1.3607.2.20.0.6400current
gopticalTerminationIncomplete
NOTIFICATION-TYPE
Optical Termination Incomplete
1.3.6.1.4.1.3607.2.20.0.6410current
gforwardDefectIndication
NOTIFICATION-TYPE
Forward Defect Indication
1.3.6.1.4.1.3607.2.20.0.6420current
gpayloadMissingIndication
NOTIFICATION-TYPE
Payload Missing Indication
1.3.6.1.4.1.3607.2.20.0.6430current
gspanMeasurementCannotBePerformed
NOTIFICATION-TYPE
Span loss not checked
1.3.6.1.4.1.3607.2.20.0.6440current
gringIsSquelchingHighOrderTraffic
NOTIFICATION-TYPE
Ring Is Squelching Higher Order Traffic
1.3.6.1.4.1.3607.2.20.0.6450current
gringIsSquelchingLowOrderTraffic
NOTIFICATION-TYPE
Ring Is Squelching Lower Order Traffic
1.3.6.1.4.1.3607.2.20.0.6460current
gbadPacketCountExceedsThreshold
NOTIFICATION-TYPE
Bad Packet Count Exceeds Threshold
1.3.6.1.4.1.3607.2.20.0.6470current
glinkLayerKeepAliveFailure
NOTIFICATION-TYPE
Link Layer Keep-Alive Failure
1.3.6.1.4.1.3607.2.20.0.6480current
gautonegotiationRemoteFailureIndication
NOTIFICATION-TYPE
Auto-Negotiation Remote Failure Indication
1.3.6.1.4.1.3607.2.20.0.6490current
gtrailSignalFail
NOTIFICATION-TYPE
Trail Signal Fail
1.3.6.1.4.1.3607.2.20.0.6500current
gds1LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
DS1 Loopback Command Sent To Far End
1.3.6.1.4.1.3607.2.20.0.6510current
gmultiplexSectionSignalDegraded
NOTIFICATION-TYPE
Multiplex Section - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6520current
gmultiplexSectionExcessiveErrors
NOTIFICATION-TYPE
Multiplex Section - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6530current
ghighOrderPathSignalDegraded
NOTIFICATION-TYPE
High Order Path - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6540current
ghighOrderPathExcessiveErrors
NOTIFICATION-TYPE
High Order Path - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6550current
glowOrderPathSignalDegraded
NOTIFICATION-TYPE
Low Order Path - Signal Degraded
1.3.6.1.4.1.3607.2.20.0.6560current
glowOrderPathExcessiveErrors
NOTIFICATION-TYPE
Low Order Path - Excessive Errors
1.3.6.1.4.1.3607.2.20.0.6570current
gregeneratorSectionDccTerminationFailure
NOTIFICATION-TYPE
Regenerator Section - DCC Termination Failure
1.3.6.1.4.1.3607.2.20.0.6580current
gnetworkMemoryPoolLow
NOTIFICATION-TYPE
Network Memory Pool Low
1.3.6.1.4.1.3607.2.20.0.6590current
gospfRoutingTableOverflow
NOTIFICATION-TYPE
OSPF Routing Table Overflow
1.3.6.1.4.1.3607.2.20.0.6600current
gautoLaserShutdownDisabled
NOTIFICATION-TYPE
Auto Laser Shutdown Disabled
1.3.6.1.4.1.3607.2.20.0.6610current
gwavelengthOutOfLock
NOTIFICATION-TYPE
Wavelength Out of Lock
1.3.6.1.4.1.3607.2.20.0.6620current
grprProtectionIsActive
NOTIFICATION-TYPE
RPR Protection Is Active
1.3.6.1.4.1.3607.2.20.0.6630current
gmaxRPRStationNumberExceeded
NOTIFICATION-TYPE
Max RPR Station Number Exceeded
1.3.6.1.4.1.3607.2.20.0.6640current
grprProtectionConfigurationMismatched
NOTIFICATION-TYPE
RPR Protection Configuration Mismatched
1.3.6.1.4.1.3607.2.20.0.6650current
greservedBandwidthLinkRateExceededOnRinglet0
NOTIFICATION-TYPE
Reserved Bandwidth Link Rate Exceeded On Ringlet0
1.3.6.1.4.1.3607.2.20.0.6660current
greservedBandwidthLinkRateExceededOnRinglet1
NOTIFICATION-TYPE
Reserved Bandwidth Link Rate Exceeded On Ringlet1
1.3.6.1.4.1.3607.2.20.0.6670current
grprInterfaceInPassThroughMode
NOTIFICATION-TYPE
RPR Interface In Pass Through Mode
1.3.6.1.4.1.3607.2.20.0.6680current
grprPeerNodeIsMissing
NOTIFICATION-TYPE
RPR Peer Node is Missing
1.3.6.1.4.1.3607.2.20.0.6690current
grprRiFailure
NOTIFICATION-TYPE
RPR RI Failure
1.3.6.1.4.1.3607.2.20.0.6700current
grprSignalFailure
NOTIFICATION-TYPE
RPR Signal Failure
1.3.6.1.4.1.3607.2.20.0.6710current
grprSignalDegrade
NOTIFICATION-TYPE
RPR Signal Degrade
1.3.6.1.4.1.3607.2.20.0.6720current
ginterlinkFailure
NOTIFICATION-TYPE
ADM Peer Cards Interlink Failure
1.3.6.1.4.1.3607.2.20.0.6730current
gapcWrongGain
NOTIFICATION-TYPE
APC Wrong Gain Set Point
1.3.6.1.4.1.3607.2.20.0.6740current
grprSpanMismatch
NOTIFICATION-TYPE
RPR Span Mismatch
1.3.6.1.4.1.3607.2.20.0.6750current
gefmRemoteFaultIndicationCriticalEvent
NOTIFICATION-TYPE
EFM Remote Fault Indication- Critical Event
1.3.6.1.4.1.3607.2.20.0.6760current
gefmRemoteFaultIndicationDyingGasp
NOTIFICATION-TYPE
EFM Remote Fault Indication- Dying Gasp
1.3.6.1.4.1.3607.2.20.0.6770current
gefmRemoteFaultIndicationLinkFault
NOTIFICATION-TYPE
EFM Remote Fault Indication- Link Fault
1.3.6.1.4.1.3607.2.20.0.6780current
gefmLinkMonitoringErroredSymbolPeriodEvent
NOTIFICATION-TYPE
EFM Link Monitoring- Errored Symbol Period Event
1.3.6.1.4.1.3607.2.20.0.6790current
gefmLinkMonitoringErroredFrameEvent
NOTIFICATION-TYPE
EFM Link Monitoring- Errored Frame Event
1.3.6.1.4.1.3607.2.20.0.6800current
gefmLinkMonitoringErroredFramePeriodEvent
NOTIFICATION-TYPE
EFM Link Monitoring- Errored Frame Period Event
1.3.6.1.4.1.3607.2.20.0.6810current
gefmLinkMonitoringErroredFrameSecondsSummary
NOTIFICATION-TYPE
EFM Link Monitoring- Errored Frame Seconds Summary
1.3.6.1.4.1.3607.2.20.0.6820current
gefmRemoteLoopbackRequestFailed
NOTIFICATION-TYPE
EFM Remote Loopback Request Failed
1.3.6.1.4.1.3607.2.20.0.6830current
gfastAutomaticProtectionSwitching
NOTIFICATION-TYPE
Fast Automatic Protection Switching
1.3.6.1.4.1.3607.2.20.0.6840current
gfastAutomaticProtectionSwitchingConfigMismatch
NOTIFICATION-TYPE
Fast Automatic Protection Switching Config Mismatch
1.3.6.1.4.1.3607.2.20.0.6850current
glcasSinkGroupError
NOTIFICATION-TYPE
LCAS Sink Group Error
1.3.6.1.4.1.3607.2.20.0.6860current
glcasVcgMemberRxSideInDnuState
NOTIFICATION-TYPE
LCAS VCG Member Rx Side In DNU State
1.3.6.1.4.1.3607.2.20.0.6870current
gfcDistanceExtFuncNotEstablished
NOTIFICATION-TYPE
Fibre Channel Distance Extension Function Not Established
1.3.6.1.4.1.3607.2.20.0.6880current
gnonCiscoPPMInserted
NOTIFICATION-TYPE
Non Cisco PPM Inserted
1.3.6.1.4.1.3607.2.20.0.6890current
gunqualifiedPPMInserted
NOTIFICATION-TYPE
Unqualified PPM Inserted
1.3.6.1.4.1.3607.2.20.0.6900current
gftaMismatch
NOTIFICATION-TYPE
FanTray Mismatch
1.3.6.1.4.1.3607.2.20.0.6910current
gcardPortsUnableToProvideProtection
NOTIFICATION-TYPE
Card/Ports Unable To Provide Protection
1.3.6.1.4.1.3607.2.20.0.6920current
glmpSignalDegrade
NOTIFICATION-TYPE
LMP Signal Degrade
1.3.6.1.4.1.3607.2.20.0.6930current
glmpSignalFailure
NOTIFICATION-TYPE
LMP Signal Failure
1.3.6.1.4.1.3607.2.20.0.6940current
gfrontPortLinkLoss
NOTIFICATION-TYPE
TCC Front Port Link Loss
1.3.6.1.4.1.3607.2.20.0.6960current
gbertEnbl
NOTIFICATION-TYPE
BERT Enabled
1.3.6.1.4.1.3607.2.20.0.6970current
gbertSyncFail
NOTIFICATION-TYPE
BERT Synchronization Status Failed
1.3.6.1.4.1.3607.2.20.0.6975current
gworkQueueFull
NOTIFICATION-TYPE
Work Queue Full
1.3.6.1.4.1.3607.2.20.0.6980current
gequipmentPowerFailureAtConnectorA
NOTIFICATION-TYPE
Equipment Power Failure At Connector A
1.3.6.1.4.1.3607.2.20.0.7000current
gequipmentPowerFailureAtConnectorB
NOTIFICATION-TYPE
Equipment Power Failure At Connector B
1.3.6.1.4.1.3607.2.20.0.7005current
gequipmentPowerFailureAtReturnConnectorA
NOTIFICATION-TYPE
Equipment Power Failure At Return Connector A
1.3.6.1.4.1.3607.2.20.0.7010current
gequipmentPowerFailureAtReturnConnectorB
NOTIFICATION-TYPE
Equipment Power Failure At Return Connector B
1.3.6.1.4.1.3607.2.20.0.7015current
gloginFailThresholdExceeded
NOTIFICATION-TYPE
Invalid login attempt threshold exceeded
1.3.6.1.4.1.3607.2.20.0.7020current
gconnectionIdMismatchOnMatrixA
NOTIFICATION-TYPE
Connection ID mismatch on Matrix A
1.3.6.1.4.1.3607.2.20.0.7025current
gconnectionIdMismatchOnMatrixB
NOTIFICATION-TYPE
Connection ID mismatch on Matrix B
1.3.6.1.4.1.3607.2.20.0.7030current
gmanufacturingEepromFailure
NOTIFICATION-TYPE
Manufacturing data memory (EEPROM) failure
1.3.6.1.4.1.3607.2.20.0.7035deprecated
gequipmentFailureHighTemperature
NOTIFICATION-TYPE
Equipment failure high temperature
1.3.6.1.4.1.3607.2.20.0.7040current
glaserBiasCurrentHigh
NOTIFICATION-TYPE
Laser bias current high
1.3.6.1.4.1.3607.2.20.0.7045current
ghighLaserTemperature
NOTIFICATION-TYPE
High laser temperature
1.3.6.1.4.1.3607.2.20.0.7050current
gbridgeAndRollHasOccurred
NOTIFICATION-TYPE
Bridge and Roll Has Occurred
1.3.6.1.4.1.3607.2.20.0.7055current
gbridgeAndRollIsPendingAValidSignal
NOTIFICATION-TYPE
Bridge and Roll is Pending a Valid Signal
1.3.6.1.4.1.3607.2.20.0.7060current
gairFlow
NOTIFICATION-TYPE
Air Flow
1.3.6.1.4.1.3607.2.20.0.7065deprecated
gpartialFanFailurePartsFailure
NOTIFICATION-TYPE
Partial Fan Failure - Parts Failure
1.3.6.1.4.1.3607.2.20.0.7070current
gunprotectedSyncronizationEquipment
NOTIFICATION-TYPE
Unprotected Synchronization Equipment
1.3.6.1.4.1.3607.2.20.0.7075current
gunprotectedMatrixEquipment
NOTIFICATION-TYPE
Unprotected Matrix Equipment
1.3.6.1.4.1.3607.2.20.0.7080current
gmatrixEquipmentUnavailable
NOTIFICATION-TYPE
Matrix Equipment Unavailable
1.3.6.1.4.1.3607.2.20.0.7085current
gcontrolBusFailureTscA
NOTIFICATION-TYPE
Control Bus Failure - TSC A
1.3.6.1.4.1.3607.2.20.0.7090current
gcontrolBusFailureTscB
NOTIFICATION-TYPE
Control Bus Failure - TSC B
1.3.6.1.4.1.3607.2.20.0.7095current
gpayloadBusFailureMatrixA
NOTIFICATION-TYPE
Payload Bus Failure - Matrix A
1.3.6.1.4.1.3607.2.20.0.7100current
gpayloadBusFailureMatrixB
NOTIFICATION-TYPE
Payload Bus Failure - Matrix B
1.3.6.1.4.1.3607.2.20.0.7105current
gmatrixOperationSuspended
NOTIFICATION-TYPE
Matrix Operation Suspended
1.3.6.1.4.1.3607.2.20.0.7110current
gclockFailureTsc
NOTIFICATION-TYPE
Clock Module Failure
1.3.6.1.4.1.3607.2.20.0.7115current
gpayloadLoopback
NOTIFICATION-TYPE
Loopback - Payload
1.3.6.1.4.1.3607.2.20.0.7120current
gdccChannelLoss
NOTIFICATION-TYPE
DCC Channel Loss
1.3.6.1.4.1.3607.2.20.0.7125current
greptPmMsgInhibited
NOTIFICATION-TYPE
Autonomous PM Report Message Inhibited
1.3.6.1.4.1.3607.2.20.0.7130current
gloopbackCrs
NOTIFICATION-TYPE
Loopback - Cross Connect
1.3.6.1.4.1.3607.2.20.0.7135current
gsyncRefFreqOutOfBound
NOTIFICATION-TYPE
Synchronization Reference Frequency Out Of Bounds
1.3.6.1.4.1.3607.2.20.0.7140current
gsystemUpgradeInProgress
NOTIFICATION-TYPE
System Upgrade In Progress
1.3.6.1.4.1.3607.2.20.0.7145current
geqptFailToBoot
NOTIFICATION-TYPE
Equipment Fails To Boot
1.3.6.1.4.1.3607.2.20.0.7150current
geqptPowerFailure
NOTIFICATION-TYPE
Equipment Power Failure
1.3.6.1.4.1.3607.2.20.0.7155current
gclockBusFailureTscA
NOTIFICATION-TYPE
Clock Bus Failure - Shelf Controller A
1.3.6.1.4.1.3607.2.20.0.7160current
gclockBusFailureTscB
NOTIFICATION-TYPE
Clock Bus Failure - Shelf Controller B
1.3.6.1.4.1.3607.2.20.0.7165current
gpowerFuseFailure
NOTIFICATION-TYPE
Power Fuse Failure
1.3.6.1.4.1.3607.2.20.0.7170current
gcontrolCommunicationsEquipmentFailure
NOTIFICATION-TYPE
Control Communication Equipment Failure
1.3.6.1.4.1.3607.2.20.0.7175current
gdifferentSoftwareVersion
NOTIFICATION-TYPE
Different Software Version
1.3.6.1.4.1.3607.2.20.0.7180current
gospfHelloFail
NOTIFICATION-TYPE
OSPF Hello Fail
1.3.6.1.4.1.3607.2.20.0.7185current
gclockModuleFrequencyMismatch
NOTIFICATION-TYPE
Clock Module Frequency Mismatch
1.3.6.1.4.1.3607.2.20.0.7190current
getherPortSwitch
NOTIFICATION-TYPE
TSC switched to alternate ethernet port
1.3.6.1.4.1.3607.2.20.0.7195current
gopenIOSlots
NOTIFICATION-TYPE
Open IO Slot(s)
1.3.6.1.4.1.3607.2.20.0.7200current
gequipmentBootInProgress
NOTIFICATION-TYPE
Equipment boot in-progress.
1.3.6.1.4.1.3607.2.20.0.7205current
glossOfClockFromMateShelfController
NOTIFICATION-TYPE
Loss of Clock from mate Shelf Controller
1.3.6.1.4.1.3607.2.20.0.7210current
gvirtualLanAlarmIndicationSignal
NOTIFICATION-TYPE
Virtual Lan AIS
1.3.6.1.4.1.3607.2.20.0.7225current
gdcuLossFailure
NOTIFICATION-TYPE
DCU Loss Failure
1.3.6.1.4.1.3607.2.20.0.7230current
gochncMaintenance
NOTIFICATION-TYPE
OCHNC Maintenance
1.3.6.1.4.1.3607.2.20.0.7235current
gramanLaserShutdown
NOTIFICATION-TYPE
Raman Laser Shutdown
1.3.6.1.4.1.3607.2.20.0.7240current
glosOfRamanSignal
NOTIFICATION-TYPE
Loss Of Raman Signal
1.3.6.1.4.1.3607.2.20.0.7245current
gmcastMacTableFull
NOTIFICATION-TYPE
Multicast Mac Address Table Full
1.3.6.1.4.1.3607.2.20.0.7250current
gmulticastMacAddressAliasing
NOTIFICATION-TYPE
Multicast Mac Address Aliasing
1.3.6.1.4.1.3607.2.20.0.7255current
gramanPwrProtOn
NOTIFICATION-TYPE
Raman Power Protection On
1.3.6.1.4.1.3607.2.20.0.7260current
gcppPeerNotResponding
NOTIFICATION-TYPE
CPP Peer Not Responding
1.3.6.1.4.1.3607.2.20.0.7265current
gvoaControlLoopDisableDueToExcessiveCounterPropagationLight
NOTIFICATION-TYPE
VOA Control Loop Disable Due To Excessive Counter-Propagation Light
1.3.6.1.4.1.3607.2.20.0.7275current
gwizardIsRunning
NOTIFICATION-TYPE
Wizard Is Running
1.3.6.1.4.1.3607.2.20.0.7280current
gramanGainNotReached
NOTIFICATION-TYPE
Raman Span Not Tuned
1.3.6.1.4.1.3607.2.20.0.7285current
gpprForwardDefectIndication
NOTIFICATION-TYPE
pprForwardDefectIndication
1.3.6.1.4.1.3607.2.20.0.7295current
gpprBackwardDefectIndication
NOTIFICATION-TYPE
pprBackwardDefectIndication
1.3.6.1.4.1.3607.2.20.0.7300current
gpprCoordinatedMaintenance
NOTIFICATION-TYPE
pprCoordinatedMaintenance
1.3.6.1.4.1.3607.2.20.0.7305current
gpprTriggerThresholdBERExceeded
NOTIFICATION-TYPE
pprTriggerThresholdBERExceeded
1.3.6.1.4.1.3607.2.20.0.7310current
glocalFault
NOTIFICATION-TYPE
Local Fault
1.3.6.1.4.1.3607.2.20.0.7315current
gremoteFault
NOTIFICATION-TYPE
Remote Fault
1.3.6.1.4.1.3607.2.20.0.7320current
gefmRemoteLoopbackConfigured
NOTIFICATION-TYPE
EFM Port In Remote Loopback
1.3.6.1.4.1.3607.2.20.0.7325current
gefmPeerMissing
NOTIFICATION-TYPE
EFM Link To Peer Missing
1.3.6.1.4.1.3607.2.20.0.7330current
geqptDegrade
NOTIFICATION-TYPE
Equipment Degrade
1.3.6.1.4.1.3607.2.20.0.7335current
gexcessiveBackPropagation
NOTIFICATION-TYPE
Excessive Back Propagation
1.3.6.1.4.1.3607.2.20.0.7340current
gremoteMaintenanceEndPointIsDown
NOTIFICATION-TYPE
CFM Remote Maintenance End Point Is Down
1.3.6.1.4.1.3607.2.20.0.7345current
gcrossConnectedCFMService
NOTIFICATION-TYPE
Cross Connected CFM Service
1.3.6.1.4.1.3607.2.20.0.7350current
gcfmLoop
NOTIFICATION-TYPE
CFM Loop
1.3.6.1.4.1.3607.2.20.0.7355current
gcfmConfigurationError
NOTIFICATION-TYPE
CFM Configuration Error
1.3.6.1.4.1.3607.2.20.0.7360current
goutOfChannelGroupBundle
NOTIFICATION-TYPE
Out Of Channel Group Bundle
1.3.6.1.4.1.3607.2.20.0.7365current
grepNeighborAdjacencyFailure
NOTIFICATION-TYPE
REP Neighbor Adjacency Failure
1.3.6.1.4.1.3607.2.20.0.7370current
grepLinkFlapping
NOTIFICATION-TYPE
REP Link Flapping
1.3.6.1.4.1.3607.2.20.0.7375current
gfaultInREPSegment
NOTIFICATION-TYPE
Fault In REP Segment
1.3.6.1.4.1.3607.2.20.0.7380current
gprimaryREPEdgePortElected
NOTIFICATION-TYPE
Primary REP Edge Port Elected
1.3.6.1.4.1.3607.2.20.0.7385current
gsecondaryREPEdgePortElected
NOTIFICATION-TYPE
Secondary REP Edge Port Elected
1.3.6.1.4.1.3607.2.20.0.7390current
gstcnREPGenerated
NOTIFICATION-TYPE
STCN REP Generated
1.3.6.1.4.1.3607.2.20.0.7395current
gvlbREPActivated
NOTIFICATION-TYPE
VLB REP Activated
1.3.6.1.4.1.3607.2.20.0.7400current
gvlbREPTriggerSoakingDelayActive
NOTIFICATION-TYPE
VLB REP Trigger Soaking Delay Active
1.3.6.1.4.1.3607.2.20.0.7405current
gwanSyncloss
NOTIFICATION-TYPE
Ethernet Syncloss On WAN Port
1.3.6.1.4.1.3607.2.20.0.7410current
glaserShutdownDueToWavelengthDrift
NOTIFICATION-TYPE
laser Shutdown Due To Wavelength Drift
1.3.6.1.4.1.3607.2.20.0.7415current
gmanualLaserRestart
NOTIFICATION-TYPE
manual Laser Restart
1.3.6.1.4.1.3607.2.20.0.7420current
glaserShutdownDueToNonCiscoPPMInserted
NOTIFICATION-TYPE
laserShutdownDueToNonCiscoPPMInserted
1.3.6.1.4.1.3607.2.20.0.7425current
gethernetOSCTerminationFailure
NOTIFICATION-TYPE
Ethernet OSC Termination Failure
1.3.6.1.4.1.3607.2.20.0.7430current
gsoftwareSignatureVerificationFailed
NOTIFICATION-TYPE
software Signature Verification Failed
1.3.6.1.4.1.3607.2.20.0.7445current
gprotectVolumeSoftwareSignatureVerificationFailed
NOTIFICATION-TYPE
Protect Volume Software Signature Verification
1.3.6.1.4.1.3607.2.20.0.7450current
gactiveVolumeSoftwareSignatureVerificationFailed
NOTIFICATION-TYPE
Active Software Signature Verification Failed
1.3.6.1.4.1.3607.2.20.0.7455current
gpeerPortClientSignalFailDetected
NOTIFICATION-TYPE
Peer Port Client Signal Fail Detected
1.3.6.1.4.1.3607.2.20.0.7460current
gchannelShutdownDuetoWavelengthDrift
NOTIFICATION-TYPE
Channel Shutdown Due to Wavelength Drift
1.3.6.1.4.1.3607.2.20.0.7465current
gusbWriteFailure
NOTIFICATION-TYPE
USB Write Failure
1.3.6.1.4.1.3607.2.20.0.7475current
gusbSyncInProgress
NOTIFICATION-TYPE
USB Sync in Progress
1.3.6.1.4.1.3607.2.20.0.7480current
gautoSensingUnableToDetectValidPayload
NOTIFICATION-TYPE
Auto-Sensing Unable To Detect Valid Payload
1.3.6.1.4.1.3607.2.20.0.7485current
gpayloadAutoSensingInProgress
NOTIFICATION-TYPE
Payload Auto-Sensing In Progress
1.3.6.1.4.1.3607.2.20.0.7490current
ggfpClientSignalFailDetectedDueToSigloss
NOTIFICATION-TYPE
GFP Client Signal Fail Detected Due To Sigloss
1.3.6.1.4.1.3607.2.20.0.7495current
ggfpClientSignalFailDetectedDueToSyncloss
NOTIFICATION-TYPE
GFP Client Signal Fail Detected Due To Syncloss
1.3.6.1.4.1.3607.2.20.0.7500current
gpmdDegrade
NOTIFICATION-TYPE
PMD Degrade
1.3.6.1.4.1.3607.2.20.0.7510current
gstandbyTccNEClockIsInternalClock
NOTIFICATION-TYPE
Standby Tcc NE Clock Is Internal Clock
1.3.6.1.4.1.3607.2.20.0.7515current
gchromaticDispersionValue
NOTIFICATION-TYPE
chromatic Dispersion Value
1.3.6.1.4.1.3607.2.20.0.7520current
gpacketTransportServiceFailed
NOTIFICATION-TYPE
packetTransportServiceFailed
1.3.6.1.4.1.3607.2.20.0.7525current
gsatellitePanelDiscoveryFailure
NOTIFICATION-TYPE
Satellite Panel Discovery Failure
1.3.6.1.4.1.3607.2.20.0.7530current
gsatellitePanelActiveLinkFailure
NOTIFICATION-TYPE
Satellite Panel Active Link Failure
1.3.6.1.4.1.3607.2.20.0.7535current
gsatellitePanelCommunicationFailure
NOTIFICATION-TYPE
Satellite Panel Communication Failure
1.3.6.1.4.1.3607.2.20.0.7540current
gsatellitePanelImproperConfiguration
NOTIFICATION-TYPE
Satellite Panel Improper Configuration
1.3.6.1.4.1.3607.2.20.0.7545current
gsatellitePanelFanMismatchOfEquipmentAndAttributes
NOTIFICATION-TYPE
Satellite Panel Fan Mismatch Of Equipment And Attributes
1.3.6.1.4.1.3607.2.20.0.7550current
gsatellitePanelFanFailure
NOTIFICATION-TYPE
Satellite Panel Fan Failure
1.3.6.1.4.1.3607.2.20.0.7555current
gsatellitePanelPartialFanFailure
NOTIFICATION-TYPE
Satellite Panel Partial Fan Failure
1.3.6.1.4.1.3607.2.20.0.7560current
gsatellitePanelFANManufacturingDataMemoryEEPROMFailure
NOTIFICATION-TYPE
Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
1.3.6.1.4.1.3607.2.20.0.7565current
gsatellitePanelFANUnitIsMissing
NOTIFICATION-TYPE
Satellite Panel FAN Unit Is Missing
1.3.6.1.4.1.3607.2.20.0.7570current
gsatellitePanelIndustrialHighTemperature
NOTIFICATION-TYPE
Satellite Panel Industrial High Temperature
1.3.6.1.4.1.3607.2.20.0.7575current
gsatellitePanelHighTemperature
NOTIFICATION-TYPE
Satellite Panel High Temperature
1.3.6.1.4.1.3607.2.20.0.7580current
gsatellitePanelBatteryFailureA
NOTIFICATION-TYPE
Satellite Panel Battery Failure A
1.3.6.1.4.1.3607.2.20.0.7585current
gplannedSwitchOver
NOTIFICATION-TYPE
Planned Switch Over
1.3.6.1.4.1.3607.2.20.0.7590current
gprotectionCardConfigurationMismatch
NOTIFICATION-TYPE
protection Card Configuration Mismatch
1.3.6.1.4.1.3607.2.20.0.7595current
grouterProcessorSwitchOver
NOTIFICATION-TYPE
Router Processor Switch Over
1.3.6.1.4.1.3607.2.20.0.7600current
grunningLowOnResources
NOTIFICATION-TYPE
Running Low On Resources
1.3.6.1.4.1.3607.2.20.0.7605current
gnoMoreResourcesAreAvailable
NOTIFICATION-TYPE
No More Resources Are Available
1.3.6.1.4.1.3607.2.20.0.7610current
gesmcFailure
NOTIFICATION-TYPE
ESMC Failure
1.3.6.1.4.1.3607.2.20.0.7615current
glicenseWillExpireWithin24Hours
NOTIFICATION-TYPE
license Will Expire Within 24 Hours
1.3.6.1.4.1.3607.2.20.0.7620current
glicenseWillExpireAnytimeAfter1DayButBefore14Days
NOTIFICATION-TYPE
license Will Expire Anytime After 1Day But Before 14 Days
1.3.6.1.4.1.3607.2.20.0.7625current
glicenseIsExpired
NOTIFICATION-TYPE
license Is Expired
1.3.6.1.4.1.3607.2.20.0.7630current
glicenseCountViolation
NOTIFICATION-TYPE
license Count Violation
1.3.6.1.4.1.3607.2.20.0.7635current
gtemporaryLicenseIsInUse
NOTIFICATION-TYPE
Temporary License Is In Use
1.3.6.1.4.1.3607.2.20.0.7640current
gevaluationLicenseIsInUse
NOTIFICATION-TYPE
Evaluation License Is In Use
1.3.6.1.4.1.3607.2.20.0.7645current
glicenseIsMissing
NOTIFICATION-TYPE
License Is Missing
1.3.6.1.4.1.3607.2.20.0.7650current
gpseudowireDown
NOTIFICATION-TYPE
Pseudowire Down
1.3.6.1.4.1.3607.2.20.0.7655current
gworkingPseudowireControlPlaneDown
NOTIFICATION-TYPE
Working Pseudowire Control Plane Down
1.3.6.1.4.1.3607.2.20.0.7660current
gprotectPseudowireControlPlaneDown
NOTIFICATION-TYPE
Protect Pseudowire Control Plane Down
1.3.6.1.4.1.3607.2.20.0.7665current
gworkingPseudowireConnectivityCheckDown
NOTIFICATION-TYPE
Working Pseudowire Connectivity Check Down
1.3.6.1.4.1.3607.2.20.0.7670current
gprotectPseudowireConnectivityCheckDown
NOTIFICATION-TYPE
Protect Pseudowire Connectivity Check Down
1.3.6.1.4.1.3607.2.20.0.7675current
gpseudowireTrafficSwitchedToPretection
NOTIFICATION-TYPE
Pseudowire Traffic Switched To Pretection
1.3.6.1.4.1.3607.2.20.0.7680current
gworkingPseudowireLocalAcTxPortFault
NOTIFICATION-TYPE
Working Pseudowire Local AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7685current
gprotectPseudowireLocalAcTxPortFault
NOTIFICATION-TYPE
Protect Pseudowire Local AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7690current
gworkingPseudowireLocalAcRxPortFault
NOTIFICATION-TYPE
Working Pseudowire Local AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7695current
gprotectPseudowireLocalAcRxPortFault
NOTIFICATION-TYPE
Protect Pseudowire Local AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7700current
gworkingPseudowireRemoteAcTxPortFault
NOTIFICATION-TYPE
Working Pseudowire Remote AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7705current
gprotectPseudowireRemoteAcTxPortFault
NOTIFICATION-TYPE
Protect Pseudowire Remote AcTx Port Fault
1.3.6.1.4.1.3607.2.20.0.7710current
gworkingPseudowireRemoteAcRxPortFault
NOTIFICATION-TYPE
working Pseudowire Remote AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7715current
gprotectPseudowireRemoteAcRxPortFault
NOTIFICATION-TYPE
Protect Pseudowire Remote AcRx Port Fault
1.3.6.1.4.1.3607.2.20.0.7720current
gslaThresholdCrossAlert
NOTIFICATION-TYPE
SLA Threshold Cross Alert
1.3.6.1.4.1.3607.2.20.0.7725current
gprotectLocalPseudowireNotForwarding
NOTIFICATION-TYPE
Protect Local Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7730current
gworkingRemotePseudowireNotForwarding
NOTIFICATION-TYPE
Working Remote Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7735current
gprotectRemotePseudowireNotForwarding
NOTIFICATION-TYPE
Protect Remote Pseudowire Not Forwarding
1.3.6.1.4.1.3607.2.20.0.7740current
gtpTunnelDown
NOTIFICATION-TYPE
Tp Tunnel Down
1.3.6.1.4.1.3607.2.20.0.7745current
gworkingLabelSwitchedPathDown
NOTIFICATION-TYPE
Working Label Switched Path Down
1.3.6.1.4.1.3607.2.20.0.7750current
gprotectLabelSwitchedPathDown
NOTIFICATION-TYPE
Protect Label Switched Path Down
1.3.6.1.4.1.3607.2.20.0.7755current
gworkingLabelSwitchedPathAlarmIndicationSignal
NOTIFICATION-TYPE
Working Label Switched Path Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7760current
gprotectLabelSwitchedPathAlarmIndicationSignal
NOTIFICATION-TYPE
Protect Label Switched Path Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7765current
gworkingLabelSwitchedPathRemoteDefectIndication
NOTIFICATION-TYPE
Working Label Switched Path Remote Defect Indication
1.3.6.1.4.1.3607.2.20.0.7770current
gprotectLabelSwitchedPathRemoteDefectIndication
NOTIFICATION-TYPE
Protect Label Switched Path Remote Defect Indication
1.3.6.1.4.1.3607.2.20.0.7775current
gbidirectionalForwardDetectionDown
NOTIFICATION-TYPE
Bidirectional Forward Detection Down
1.3.6.1.4.1.3607.2.20.0.7780current
gtpTrafficSwitchedFromWorkingToProtection
NOTIFICATION-TYPE
Tp Traffic Switched From Working To Protection
1.3.6.1.4.1.3607.2.20.0.7785current
gworkingTpLockout
NOTIFICATION-TYPE
working Tp Lockout
1.3.6.1.4.1.3607.2.20.0.7790current
gprotectTpLockout
NOTIFICATION-TYPE
protect Tp Lockout
1.3.6.1.4.1.3607.2.20.0.7795current
gethernetFlowPointFailed
NOTIFICATION-TYPE
Ethernet Flow Point Failed
1.3.6.1.4.1.3607.2.20.0.7800current
gteTunnelDown
NOTIFICATION-TYPE
TE Tunnel Down
1.3.6.1.4.1.3607.2.20.0.7805current
gmacSystemLimitReached
NOTIFICATION-TYPE
MAC System Limit Reached
1.3.6.1.4.1.3607.2.20.0.7810current
gmacBridgeDomainLimitReached
NOTIFICATION-TYPE
MAC Bridge Domain Limit Reached
1.3.6.1.4.1.3607.2.20.0.7815current
gautoSensingDisabled
NOTIFICATION-TYPE
Auto Sense Disabled
1.3.6.1.4.1.3607.2.20.0.7820current
gsmBackwardIncomingAlignmentError
NOTIFICATION-TYPE
SM Backward Incoming Alignment Error
1.3.6.1.4.1.3607.2.20.0.7825current
gresourceAllocationFailed
NOTIFICATION-TYPE
Resource Allocation Failed
1.3.6.1.4.1.3607.2.20.0.7830current
glossOfDFBSignal
NOTIFICATION-TYPE
loss Of DFB Signal
1.3.6.1.4.1.3607.2.20.0.7835current
gworkingLabelSwitchedPathLinkDownIndication
NOTIFICATION-TYPE
Working Label Switched Path Link Down Indication
1.3.6.1.4.1.3607.2.20.0.7840current
gprotectLabelSwitchedPathLinkDownIndication
NOTIFICATION-TYPE
Protect Label Switched Path Link Down Indication
1.3.6.1.4.1.3607.2.20.0.7845current
gworkingLabelSwitchedPathLockReport
NOTIFICATION-TYPE
Working Label Switched Path Lock Report
1.3.6.1.4.1.3607.2.20.0.7850current
gprotectLabelSwitchedPathLockReport
NOTIFICATION-TYPE
Protect Label Switched Path Lock Report
1.3.6.1.4.1.3607.2.20.0.7855current
gsatellitePanelBatteryFailureB
NOTIFICATION-TYPE
satellite Panel Battery FailureB
1.3.6.1.4.1.3607.2.20.0.7860current
ghighBitErrorRate
NOTIFICATION-TYPE
High Bit Error Rate
1.3.6.1.4.1.3607.2.20.0.7865current
gbackPanelFacilityLoopback
NOTIFICATION-TYPE
Back Panel Facility Loopback
1.3.6.1.4.1.3607.2.20.0.7870current
gbackPanelTerminalLoopback
NOTIFICATION-TYPE
Back Panel Terminal Loopback
1.3.6.1.4.1.3607.2.20.0.7875current
gtrunkPayloadTypeMismatch
NOTIFICATION-TYPE
Payload Mismatch
1.3.6.1.4.1.3607.2.20.0.7880current
ginvalidMuxponderConfiguration
NOTIFICATION-TYPE
Invalid Muxponder Configuration
1.3.6.1.4.1.3607.2.20.0.7885current
gcoolingProfileMismatch
NOTIFICATION-TYPE
Cooling Profile Mismatch
1.3.6.1.4.1.3607.2.20.0.7890current
gtrunkOduAlarmIndicationSignal
NOTIFICATION-TYPE
Trunk ODU: Alarm Indication Signal
1.3.6.1.4.1.3607.2.20.0.7895current
gcompanionCardMissing
NOTIFICATION-TYPE
Companion Card Missing
1.3.6.1.4.1.3607.2.20.0.7900current
gcontrolPlaneUnverifiedClearedAlarmsPresent
NOTIFICATION-TYPE
Control Plane Unverified Cleared Alarms Present
1.3.6.1.4.1.3607.2.20.0.7905current
gpowerConsumptionLimitHasCrossed
NOTIFICATION-TYPE
Power Consumption Limit Has Crossed
1.3.6.1.4.1.3607.2.20.0.7910current
gmasterKeyExchangeFailed
NOTIFICATION-TYPE
Master Key Exchange Failed
1.3.6.1.4.1.3607.2.20.0.7915current
gunitHighTemperature
NOTIFICATION-TYPE
Unit High Temperature
1.3.6.1.4.1.3607.2.20.0.7930current
goverTemperatureUnitProtected
NOTIFICATION-TYPE
Over Temperature Unit Protected
1.3.6.1.4.1.3607.2.20.0.7935current
gseqMismatchCount
NOTIFICATION-TYPE
Sequence Mismatch Count
1.3.6.1.4.1.3607.2.20.0.7945current
gkeyProgramOnAlteraFpgaFailed
NOTIFICATION-TYPE
Key Program On Altera FPGA Failed
1.3.6.1.4.1.3607.2.20.0.7960current
gduplicateNodeControllerDetected
NOTIFICATION-TYPE
Duplicate Node Controller Detected
1.3.6.1.4.1.3607.2.20.0.7970current
grestorationInProg
NOTIFICATION-TYPE
Restoration in Progress
1.3.6.1.4.1.3607.2.20.0.7975current
gramanPumpsCalibrationProcedureIsRunning
NOTIFICATION-TYPE
Raman Calibration Running
1.3.6.1.4.1.3607.2.20.0.7980current
gramanPumpsCalibrationIsScheduledToRunInTheNextMinutes
NOTIFICATION-TYPE
Raman Calibration Pending
1.3.6.1.4.1.3607.2.20.0.7985current
godukTCM1AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk Alarm Indication Signal TCM1
1.3.6.1.4.1.3607.2.20.0.13100current
godukTCM2AlarmIndicationSignal
NOTIFICATION-TYPE
ODUk Alarm Indication Signal TCM2
1.3.6.1.4.1.3607.2.20.0.13105current
godukLockedDefectTCM1
NOTIFICATION-TYPE
ODUk Locked Defect - TCM1
1.3.6.1.4.1.3607.2.20.0.13110current
godukLockedDefectTCM2
NOTIFICATION-TYPE
ODUk Locked Defect - TCM2
1.3.6.1.4.1.3607.2.20.0.13115current
gotukLossOfFrame
NOTIFICATION-TYPE
OTUk: Loss Of Frame
1.3.6.1.4.1.3607.2.20.0.13120current
godukOpenConnectionIndicationTCM1
NOTIFICATION-TYPE
ODUk Open Connection Indication TCM1
1.3.6.1.4.1.3607.2.20.0.13125current
godukOpenConnectionIndicationTCM2
NOTIFICATION-TYPE
ODUk Open Connection Indication TCM2
1.3.6.1.4.1.3607.2.20.0.13130current
godukTrailTraceIdentifierMismatchTCM1
NOTIFICATION-TYPE
ODUk Trail Trace Identifier Mismatch TCM1
1.3.6.1.4.1.3607.2.20.0.13135current
godukTrailTraceIdentifierMismatchTCM2
NOTIFICATION-TYPE
ODUk Trail Trace Identifier Mismatch TCM2
1.3.6.1.4.1.3607.2.20.0.13140current
godukSignalFailureTCM1
NOTIFICATION-TYPE
ODUk Signal Failure - TCM1
1.3.6.1.4.1.3607.2.20.0.13145current
godukSignalFailureTCM2
NOTIFICATION-TYPE
ODUk Signal Failure - TCM2
1.3.6.1.4.1.3607.2.20.0.13150current
godukSignalDegradeTCM1
NOTIFICATION-TYPE
ODUk Signal Degrade - TCM1
1.3.6.1.4.1.3607.2.20.0.13155current
godukSignalDegradeTCM2
NOTIFICATION-TYPE
ODUk Signal Degrade - TCM2
1.3.6.1.4.1.3607.2.20.0.13160current
glossOfChannel
NOTIFICATION-TYPE
Loss of Channel
1.3.6.1.4.1.3607.2.20.0.13165current
gfecMismatch
NOTIFICATION-TYPE
FEC Mismatch
1.3.6.1.4.1.3607.2.20.0.13170current
gtimSectionMonitorTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
TIM Section Monitor - Trace Identifier Mismatch Failure
1.3.6.1.4.1.3607.2.20.0.13175current
gautomaticLaserShutdown
NOTIFICATION-TYPE
Automatic Laser Shutdown
1.3.6.1.4.1.3607.2.20.0.13180current
gshutterInsertionLossVariationDegradeLow
NOTIFICATION-TYPE
Shutter Insertion Loss Variation Degrade Low
1.3.6.1.4.1.3607.2.20.0.13200current
gopticalChannelDeactivationFailure
NOTIFICATION-TYPE
Optical Channel de-activation failure
1.3.6.1.4.1.3607.2.20.0.13205current
gshutterInsertionLossVariationDegradeHigh
NOTIFICATION-TYPE
Shutter Insertion Loss Variation Degrade High
1.3.6.1.4.1.3607.2.20.0.13210current
gnetworkTopologyIncomplete
NOTIFICATION-TYPE
Network Topology Incomplete
1.3.6.1.4.1.3607.2.20.0.13215current
gpluginModuleCommunicationFailure
NOTIFICATION-TYPE
Plug-in Module Communication Failure
1.3.6.1.4.1.3607.2.20.0.13220current
gopticalNetworkTypeMismatch
NOTIFICATION-TYPE
Optical Network Type Mismatch
1.3.6.1.4.1.3607.2.20.0.13225current
gopticalPowerDegradeLow
NOTIFICATION-TYPE
Laser Power Degrade Low
1.3.6.1.4.1.3607.2.20.0.13230current
gautomaticPowerControlFailure
NOTIFICATION-TYPE
Automatic Power Control Failure
1.3.6.1.4.1.3607.2.20.0.13235current
gopticalPowerDegradeHigh
NOTIFICATION-TYPE
Optical Power Degrade High
1.3.6.1.4.1.3607.2.20.0.13240current
gautomaticPowerControlDisabled
NOTIFICATION-TYPE
Automatic Power Control Disabled
1.3.6.1.4.1.3607.2.20.0.13245current
gopticalPowerFailureLow
NOTIFICATION-TYPE
Optical Power Failure Low
1.3.6.1.4.1.3607.2.20.0.13250current
gringIdMismatch
NOTIFICATION-TYPE
Ring Id Mismatch
1.3.6.1.4.1.3607.2.20.0.13255current
gopticalPowerFailureHigh
NOTIFICATION-TYPE
Optical Power Failure High
1.3.6.1.4.1.3607.2.20.0.13260current
glossOfContinuity
NOTIFICATION-TYPE
Loss Of Continuity
1.3.6.1.4.1.3607.2.20.0.13270current
gvariableOpticalAttenuatorDegradeLow
NOTIFICATION-TYPE
Variable Optical Attenuator Degrade Low
1.3.6.1.4.1.3607.2.20.0.13280current
gvariableOpticalAttenuatorDegradeHigh
NOTIFICATION-TYPE
Variable Optical Attenuator Degrade High
1.3.6.1.4.1.3607.2.20.0.13290current
gvariableOpticalAttenuatorFailureLow
NOTIFICATION-TYPE
Variable Optical Attenuator Failure Low
1.3.6.1.4.1.3607.2.20.0.13300current
gvariableOpticalAttenuatorFailureHigh
NOTIFICATION-TYPE
Variable Optical Attenuator Failure High
1.3.6.1.4.1.3607.2.20.0.13310current
glaserBiasDegrade
NOTIFICATION-TYPE
Laser Bias Degrade
1.3.6.1.4.1.3607.2.20.0.13320current
glaserBiasFailure
NOTIFICATION-TYPE
aser Bias Failure
1.3.6.1.4.1.3607.2.20.0.13330current
glaserTemperatureDegrade
NOTIFICATION-TYPE
Laser Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13340current
gopticalAmplifierGainDegradeLow
NOTIFICATION-TYPE
Optical Amplifier Gain Degrade Low
1.3.6.1.4.1.3607.2.20.0.13350current
gopticalAmplifierGainDegradeHigh
NOTIFICATION-TYPE
Optical Amplifier Gain Degrade High
1.3.6.1.4.1.3607.2.20.0.13360current
gopticalAmplifierGainFailureLow
NOTIFICATION-TYPE
Optical Amplifier Gain Failure Low
1.3.6.1.4.1.3607.2.20.0.13370current
gopticalAmplifierGainFailureHigh
NOTIFICATION-TYPE
Optical Amplifier Gain Failure High
1.3.6.1.4.1.3607.2.20.0.13380current
gopticalChannelConnectionFailure
NOTIFICATION-TYPE
Optical Channel connection failure
1.3.6.1.4.1.3607.2.20.0.13390current
gopticalChannelIncomplete
NOTIFICATION-TYPE
Optical Channel Incomplete
1.3.6.1.4.1.3607.2.20.0.13395current
gopticalChannelActivationFailure
NOTIFICATION-TYPE
Optical Channel activation failure
1.3.6.1.4.1.3607.2.20.0.13400current
glaserAutoPowerReduction
NOTIFICATION-TYPE
Laser Auto Power Reduction
1.3.6.1.4.1.3607.2.20.0.13410current
gcaseTemperatureDegrade
NOTIFICATION-TYPE
Case Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13420current
gfiberTemperatureDegrade
NOTIFICATION-TYPE
Fiber Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13430current
gshutterOpen
NOTIFICATION-TYPE
Shutter Failure
1.3.6.1.4.1.3607.2.20.0.13440current
gawgTemperatureDegrade
NOTIFICATION-TYPE
AWG Temperature Degrade
1.3.6.1.4.1.3607.2.20.0.13450current
gawgTemperatureFailure
NOTIFICATION-TYPE
AWG Temperature Failure
1.3.6.1.4.1.3607.2.20.0.13460current
gawgOverTemperature
NOTIFICATION-TYPE
AWG Over-Temperature
1.3.6.1.4.1.3607.2.20.0.13470current
gopticalAmplifierInitialization
NOTIFICATION-TYPE
Optical Amplifier Initialization
1.3.6.1.4.1.3607.2.20.0.13480current
gawgWarmUp
NOTIFICATION-TYPE
AWG Warm Up
1.3.6.1.4.1.3607.2.20.0.13490current
gincSigloss
NOTIFICATION-TYPE
Incoming Signal Loss on Fibre Channel Interface
1.3.6.1.4.1.3607.2.20.0.13510current
gincSyncloss
NOTIFICATION-TYPE
Incoming Synchronization Loss on Fibre Channel Interface
1.3.6.1.4.1.3607.2.20.0.13515current
gincGfpOutOfFrame
NOTIFICATION-TYPE
Out Of Frame Detected by GFP Receiver
1.3.6.1.4.1.3607.2.20.0.13520current
gincGfpSigLoss
NOTIFICATION-TYPE
Client Signal Loss Frames Detected by GFP Receiver
1.3.6.1.4.1.3607.2.20.0.13525current
gincGfpSyncLoss
NOTIFICATION-TYPE
Client Sychronization Loss Frames Detected by GFP Receiver
1.3.6.1.4.1.3607.2.20.0.13530current

Conformance

NameOIDStatus
nodeGenericGroup
OBJECT-GROUP
The group for node related objects
1.3.6.1.4.1.3607.5.10.10.10current
alarmGenericGroup
OBJECT-GROUP
The group for node related objects
1.3.6.1.4.1.3607.5.10.10.20current
eventGenericGroup
NOTIFICATION-GROUP
The generic notifications for Cisco ONS network device, ONS 15327, 15310
1.3.6.1.4.1.3607.5.10.10.30current
cerentGenericCommonGroup
OBJECT-GROUP
The objects related to traps dispatch
1.3.6.1.4.1.3607.5.10.10.40current
cerentThresholdGroup
OBJECT-GROUP
The objects for storing all the current alarms
1.3.6.1.4.1.3607.5.10.10.50current
eventGenericDeprecatedGroup
NOTIFICATION-GROUP
The deprecated notifications for Cisco ONS network devices
1.3.6.1.4.1.3607.5.10.10.60deprecated
reportedAlarmGenericGroup
OBJECT-GROUP
The group for reported alarm objects
1.3.6.1.4.1.3607.5.10.10.70current
cerentGenericBasicCompliance
MODULE-COMPLIANCE
The basic implementation requirements for Cisco ONS network device, ONS 15327, 15310
1.3.6.1.4.1.3607.5.10.20.10current