MIBs Depot

CAMBIUM-PTP600-MIB

Registered at
1.3.6.1.4.1.17713.6
Last updated
2014-03-04 14:14
Organization
Cambium Networks Ltd.
Revisions
2014-03-04 14:14, 2013-09-14 23:38, 2012-08-13 18:12, 2012-05-01 11:58, 2012-02-13 12:38, 2011-11-08 13:47, 2010-12-07 13:28, 2010-11-02 13:33, 2010-07-16 15:41, 2010-04-23 10:07, 2010-02-19 18:55, 2009-07-10 15:20, 2009-02-27 17:11, 2008-12-15 12:19, 2008-06-30 10:16, 2008-02-29 09:42, 2007-07-31 18:39, 2006-11-23 14:36, 2006-07-24 10:08
Namespace
cambium
Source file
CAMBIUM-PTP600-MIB
Digest
sha256:421c53323c570c7471b62e79d371a80a23a06daf860b37fc2d008912b1f55e44

Description

MIB for 300Mbps non-line-of-sight (NLOS) wireless ethernet bridge.

Contact

Post: Simon Whitaker Cambium Networks Ltd. Unit B2, Linhay Business Park, Eastern Road, Ashburton, Devon. TQ13 7UP United Kingdom Phone: +44 (0) 1364 655 500 Email: simon.whitaker@cambiumnetworks.com

Imports

FromSymbols
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CAMBIUM-PTP600-MIB
INET-ADDRESS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ptp
OBJECT-IDENTITY
1.3.6.1.4.1.17713.1
ptmp
OBJECT-IDENTITY
1.3.6.1.4.1.17713.2
ptp600
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6
dfs
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.3
dfsTableNumber
OBJECT-TYPE
Number of entries in the dfsTable
1.3.6.1.4.1.17713.6.3.1INTEGER (1..63)read-onlycurrent
dfsTable
OBJECT-TYPE
A table storing a snapshot of various DFS measurements for each channel
1.3.6.1.4.1.17713.6.3.2not-accessiblecurrent
dfsTableEntry
OBJECT-TYPE
Table DfsTable
1.3.6.1.4.1.17713.6.3.2.1not-accessiblecurrent
dfsTableIndex
OBJECT-TYPE
used to index values in the dfsTable.
1.3.6.1.4.1.17713.6.3.2.1.1INTEGER (1..63)not-accessiblecurrent
dfsMeans
OBJECT-TYPE
Snapshot of DFS means
1.3.6.1.4.1.17713.6.3.2.1.2Integer32read-onlycurrent
dfsNineNinePointNinePercentiles
OBJECT-TYPE
Snapshot of DFS 99.9 percentiles
1.3.6.1.4.1.17713.6.3.2.1.3Integer32read-onlycurrent
dfsPeaks
OBJECT-TYPE
Snapshot of DFS peaks
1.3.6.1.4.1.17713.6.3.2.1.4Integer32read-onlycurrent
bridge
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.4
localPacketFiltering
OBJECT-TYPE
When Local Packet Filtering is Enabled, the bridge learns the source MAC addresses of devices transmitting Ethernet packets on the local Ethernet network, and only bridges packets to the remote unit if the destination MAC address has not been learnt as a 'local' device. When Local Packet Filtering is Disabled then the bridge does not learn the source MAC addresses of devices transmitting Ethernet packets on the local Ethernet network, and bridges ALL Ethernet packets received to the remote unit. Local Packet Filtering should be enabled if no external routing hardware is present
1.3.6.1.4.1.17713.6.4.1INTEGER {disabled(0), enabled(1)}read-writecurrent
configuration
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.5
iPv4Address
OBJECT-TYPE
Internet protocol (IPv4) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network. NB: A system reboot is required to activate changes to this attribute.
1.3.6.1.4.1.17713.6.5.1IpAddressread-writecurrent
subnetMask
OBJECT-TYPE
A subnet allows the flow of network traffic between hosts to be segregated based on a network configuration. By organizing hosts into logical groups, subnetting can improve network security and performance. NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.5.2IpAddressread-writecurrent
gatewayIPAddress
OBJECT-TYPE
The IPv4 address of a computer on the current network that is currently acting as an IPv4 network gateway. A gateway acts as an entrance / exit to packets from / to other networks. NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.5.3IpAddressread-writecurrent
targetMACAddress
OBJECT-TYPE
MAC address of the PTP wireless unit forming the other end of the PTP link
1.3.6.1.4.1.17713.6.5.4OCTET STRING (SIZE(6))read-onlycurrent
masterSlaveMode
OBJECT-TYPE
The PTP wireless link operates using a master and slave relationship
1.3.6.1.4.1.17713.6.5.5INTEGER {master(0), slave(1)}read-writecurrent
maximumTransmitPower
OBJECT-TYPE
Maximum transmit power the wireless unit is permitted to use when establishing and maintaining the wireless link
1.3.6.1.4.1.17713.6.5.6INTEGER (-15..27)read-onlycurrent
antennaGain
OBJECT-TYPE
Antenna Gain. Expressed in 10ths of dBi. NB: This attribute is ignored for variants with an integral antenna.
1.3.6.1.4.1.17713.6.5.7INTEGER (0..610)read-writecurrent
cableLoss
OBJECT-TYPE
Loss in the cable between the ODU and the antenna. Expressed in 10ths of dB. NB: This attribute is ignored for variants with an integral antenna.
1.3.6.1.4.1.17713.6.5.8INTEGER (0..255)read-writecurrent
eIRP
OBJECT-TYPE
Effective Isotropic Radiated Power (EIRP) describes the strength of the radio signal leaving the wireless unit. Expressed in 10ths of dBm
1.3.6.1.4.1.17713.6.5.9Integer32read-onlycurrent
ethernetCappedMaxWirelessSpeed
OBJECT-TYPE
Ethernet frames will be discarded in the ODU if the data rate over the wireless link exceeds the Ethernet link speed at the local or remote Data port. The Ethernet Capped Max Wireless Speed control limits the wireless data rate based on the local and remote Ethernet link speed. Set this control to Enabled if either ODU is connected to an Ethernet link operating at less than 1000 Mbps. NB: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard.
1.3.6.1.4.1.17713.6.5.10INTEGER {disabled(0), enabled(1)}read-writecurrent
channelBandwidth
OBJECT-TYPE
This control sets the bandwidth of the transmit and receive radio channels
1.3.6.1.4.1.17713.6.5.11INTEGER {bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4)}read-onlycurrent
remoteIPAddress
OBJECT-TYPE
IP Address of the peer wireless unit
1.3.6.1.4.1.17713.6.5.12IpAddressread-onlycurrent
linkName
OBJECT-TYPE
Name of the PTP link allocated by the System Administrator. Used to establish a connection with the correct PTP wireless unit at the other end of the link. NOTE: The link name MUST be the same at both ends of the PTP link.
1.3.6.1.4.1.17713.6.5.14DisplayString (SIZE(0..63))read-writecurrent
siteName
OBJECT-TYPE
This field contains a user-provided description of the site name together with any additional notes
1.3.6.1.4.1.17713.6.5.15DisplayString (SIZE(0..63))read-writecurrent
accessMethod
OBJECT-TYPE
ODUs must be configured in pairs before a link can be established. The Access Method attribute determines how the paired ODUs will recognise each other. For the Link Access method, each ODU must be configured with Target MAC Address equal to the MAC Address of the other unit. For the Link Name Access method, both units must be configured with the same Link Name. For the Group Access method, both units must be configured with the same Group ID.
1.3.6.1.4.1.17713.6.5.16INTEGER {linkAccess(0), linkNameAccess(1), groupAccess(2)}read-onlycurrent
groupID
OBJECT-TYPE
When Access Method is set to Group Access, the Group ID identifies all the units belonging to the same group
1.3.6.1.4.1.17713.6.5.17INTEGER (0..255)read-writecurrent
iPv6Address
OBJECT-TYPE
Internet protocol (IPv6) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network. NB: A system reboot is required to activate changes to this attribute.
1.3.6.1.4.1.17713.6.5.18DisplayString (SIZE(0..39))read-writecurrent
iPVersion
OBJECT-TYPE
IP protocol selection. Choice of IPv4, IPv6 or Dual.
1.3.6.1.4.1.17713.6.5.20INTEGER {iPv4(0), iPv6(1), dualIPv4andIPv6(2)}read-writecurrent
iPv6AutoConfiguredLinkLocalAddress
OBJECT-TYPE
The auto configured link local IPv6 address
1.3.6.1.4.1.17713.6.5.21DisplayString (SIZE(0..39))read-onlycurrent
iPv6PrefixLength
OBJECT-TYPE
IPv6 prefix length
1.3.6.1.4.1.17713.6.5.22INTEGER (0..128)read-writecurrent
iPv6GatewayAddress
OBJECT-TYPE
The IPv6 address of a computer on the current network that is currently acting as an IPv6 network gateway. A gateway acts as an entrance / exit to packets from / to other networks. Note that it is usual to use the link-local address of the gateway. NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.5.23DisplayString (SIZE(0..39))read-writecurrent
remoteInternetAddressType
OBJECT-TYPE
The type of Internet address specified by the associated remoteInternetAddressType.
1.3.6.1.4.1.17713.6.5.24INTEGER {unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16)}read-onlycurrent
remoteInternetAddress
OBJECT-TYPE
INET address used to identify the peer wireless unit
1.3.6.1.4.1.17713.6.5.25InetAddressread-onlycurrent
ethernet
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.6
dataPortAutoNegotiation
OBJECT-TYPE
This controls whether the local Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot.
1.3.6.1.4.1.17713.6.6.1INTEGER {disabled(0), enabled(1)}read-writecurrent
dataPortAutoNegAdvertisement
OBJECT-TYPE
This sets the different Ethernet configurations that will be advertised during auto negotiation. Note the new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!
1.3.6.1.4.1.17713.6.6.2Bits {negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), neg1000MbpsFullDuplex(7)}read-writecurrent
dataPortAutoMdix
OBJECT-TYPE
This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot
1.3.6.1.4.1.17713.6.6.3INTEGER {disabled(0), enabled(1)}read-writecurrent
dataPortStatus
OBJECT-TYPE
Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.6.4INTEGER {down(0), copperLinkUp(1), fiberLinkUp(2)}read-onlycurrent
dataPortSpeedAndDuplex
OBJECT-TYPE
The current speed and duplex of the Ethernet link
1.3.6.1.4.1.17713.6.6.5INTEGER {speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5)}read-onlycurrent
dataPortWirelessDownAlert
OBJECT-TYPE
When enabled, this causes the Ethernet link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem.
1.3.6.1.4.1.17713.6.6.6INTEGER {disabled(0), enabled(1)}read-writecurrent
useVLANForManagementInterfaces
OBJECT-TYPE
This controls whether the management interfaces (WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new setting will only take effect after a system reboot
1.3.6.1.4.1.17713.6.6.7INTEGER {noVLANTagging(0), iEEE8021QTaggedCTagType8100(1), iEEE8021adTaggedSTagorBTagType88a8(2)}read-writecurrent
vLANManagementPriority
OBJECT-TYPE
This VLAN Priority (0-7) will be included in packets generated by the management interfaces. NB: The new setting will only take effect after a system reboot
1.3.6.1.4.1.17713.6.6.8INTEGER {p0(0), p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7)}read-writecurrent
vLANManagementVID
OBJECT-TYPE
This VLAN VID (0-4094) will be included in packets generated by the management interfaces. Note the new setting will only take effect after a system reboot
1.3.6.1.4.1.17713.6.6.11INTEGER (0..4094)read-writecurrent
managementPortStatus
OBJECT-TYPE
Current status of the out-of-band management link. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.6.12INTEGER {down(0), copperLinkUp(1)}read-onlycurrent
managementPortSpeedAndDuplex
OBJECT-TYPE
The current speed and duplex of the out-of-band management link
1.3.6.1.4.1.17713.6.6.13INTEGER {speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5)}read-onlycurrent
ethernetPriorityTableNumber
OBJECT-TYPE
Number of entries in the vLANPriorityTable.
1.3.6.1.4.1.17713.6.6.14INTEGER (9)read-onlycurrent
ethernetPriorityTable
OBJECT-TYPE
A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority.
1.3.6.1.4.1.17713.6.6.15not-accessiblecurrent
ethernetPriorityTableEntry
OBJECT-TYPE
Table EthernetPriorityTable
1.3.6.1.4.1.17713.6.6.15.1not-accessiblecurrent
ethernetPriorityTableIndex
OBJECT-TYPE
Ethernet priority flag, used to index values in the ethernetPriorityTable
1.3.6.1.4.1.17713.6.6.15.1.1INTEGER {p0(1), p1(2), p2(3), p3(4), p4(5), p5(6), p6(7), p7(8), untagged(9)}not-accessiblecurrent
ethernetPriorityQueueMapping
OBJECT-TYPE
Configures the classification of this Ethernet priority (also known as IEEE 802.1p value) to an egress queue at the wireless port
1.3.6.1.4.1.17713.6.6.15.1.2INTEGER {q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7)}read-writecurrent
l2CPPriorityTableNumber
OBJECT-TYPE
Number of entries in the l2CPPriorityTable.
1.3.6.1.4.1.17713.6.6.16INTEGER (5)read-onlycurrent
l2CPPriorityTable
OBJECT-TYPE
A priority queue mapping table. This is a list of packet queues indexed by L2CP priority.
1.3.6.1.4.1.17713.6.6.17not-accessiblecurrent
l2CPPriorityTableEntry
OBJECT-TYPE
Table L2CPPriorityTable
1.3.6.1.4.1.17713.6.6.17.1not-accessiblecurrent
l2CPPriorityTableIndex
OBJECT-TYPE
L2CP priority flag, used to index values in the l2CPPriorityTable
1.3.6.1.4.1.17713.6.6.17.1.1INTEGER {bridge(1), mRP(2), cFM(3), rAPS(4), eAPS(5)}not-accessiblecurrent
l2CPPriorityQueueMapping
OBJECT-TYPE
Configures the classification of this layer two control protocol (L2CP) to an egress queue at the wireless port
1.3.6.1.4.1.17713.6.6.17.1.2INTEGER {q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7)}read-writecurrent
iPDSCPPriorityTableNumber
OBJECT-TYPE
Number of entries in the iPDSCPPriorityTable.
1.3.6.1.4.1.17713.6.6.18INTEGER (64)read-onlycurrent
iPDSCPPriorityTable
OBJECT-TYPE
A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority.
1.3.6.1.4.1.17713.6.6.19not-accessiblecurrent
iPDSCPPriorityTableEntry
OBJECT-TYPE
Table IPDSCPPriorityTable
1.3.6.1.4.1.17713.6.6.19.1not-accessiblecurrent
iPDSCPPriorityTableIndex
OBJECT-TYPE
IP DSCP priority flag, used to index values in the iPDSCPPriorityTable
1.3.6.1.4.1.17713.6.6.19.1.1INTEGER (1..64)not-accessiblecurrent
iPDSCPPriorityQueueMapping
OBJECT-TYPE
Configures the classification of this IP differentiated services code point (DSCP) value to an egress queue at the wireless port
1.3.6.1.4.1.17713.6.6.19.1.2INTEGER {q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7)}read-writecurrent
mPLSTCPriorityTableNumber
OBJECT-TYPE
Number of entries in the mPLSTCPriorityTable.
1.3.6.1.4.1.17713.6.6.20INTEGER (8)read-onlycurrent
mPLSTCPriorityTable
OBJECT-TYPE
A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority.
1.3.6.1.4.1.17713.6.6.21not-accessiblecurrent
mPLSTCPriorityTableEntry
OBJECT-TYPE
Table MPLSTCPriorityTable
1.3.6.1.4.1.17713.6.6.21.1not-accessiblecurrent
mPLSTCPriorityTableIndex
OBJECT-TYPE
MPLS TC priority flag, used to index values in the mPLSTCPriorityTable
1.3.6.1.4.1.17713.6.6.21.1.1INTEGER (1..8)not-accessiblecurrent
mPLSTCPriorityQueueMapping
OBJECT-TYPE
Configures the classification of this MPLS traffic class (the field formerly known as EXP) to an egress queue at the wireless port
1.3.6.1.4.1.17713.6.6.21.1.2INTEGER {q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7)}read-writecurrent
managementMode
OBJECT-TYPE
Out-of-Band Management (only available on certain hardware models): End-to-end out-of-band mode in which the management agent can be reached from the management port at the local ODU and (assuming that the wireless link is established) the management port at the remote ODU. Out-of-Band Local Management (only available on certain hardware models): Similar to the standard Out-of-Band mode, except that management frames are not forwarded over the wireless link. In-Band Management (default): The management agent can be reached from the data port at the local ODU and (assuming that the wireless link is established) the data port at the remote ODU. In this mode the management port is disabled. In-Band Local Management (only available when 'Use VLAN For Management Interfaces' configures a VLAN tag): Similar to the standard In-Band mode, except that management frames are not forwarded over the wireless link.
1.3.6.1.4.1.17713.6.6.22INTEGER {outofBandLocal(0), outofBand(1), inBand(2), inBandLocal(3)}read-onlycurrent
managementPortWirelessDownAlert
OBJECT-TYPE
When enabled, this causes the management link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem.
1.3.6.1.4.1.17713.6.6.23INTEGER {disabled(0), enabled(1)}read-onlycurrent
qOSPriorityScheme
OBJECT-TYPE
Selects classification based on fields in the Ethernet header (Layer 2) or in the Network header (Layer 3). The unit recognises two network layer protocols: IP and MPLS
1.3.6.1.4.1.17713.6.6.24INTEGER {ethernet(0), iPMPLS(1)}read-writecurrent
unknownNetworkPriorityQueueMapping
OBJECT-TYPE
Configures the classification of unknown network protocols to an egress queue at the wireless port. Unknown means something other than IP and MPLS
1.3.6.1.4.1.17713.6.6.25INTEGER {q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7)}read-writecurrent
dSCPManagementPriority
OBJECT-TYPE
This Differentiated Services Code Point value will be inserted in the IP Header of all IP Datagrams transmitted by the management interfaces
1.3.6.1.4.1.17713.6.6.26INTEGER (0..63)read-onlycurrent
ethernetBridgingStatus
OBJECT-TYPE
Current status of Ethernet packet bridging over the wireless link
1.3.6.1.4.1.17713.6.6.27INTEGER {disabled(0), enabled(1)}read-onlycurrent
telecom
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.7
telecomsInterface
OBJECT-TYPE
The line interface type. If this is set to 'None' then the telecoms interfaces are disabled, and the telecom group attributes will be ignored.
1.3.6.1.4.1.17713.6.7.1INTEGER {none(0), e1(1), t1(2)}read-onlycurrent
telecomsChannelAStatus
OBJECT-TYPE
Current status of telecoms channel A. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.7.2INTEGER {disabled(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), up(4), remoteTiming(5), noSignalLocalandRemoteTiming(6)}read-onlycurrent
telecomsChannelBStatus
OBJECT-TYPE
Current status of telecoms channel B. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.7.3INTEGER {disabled(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), up(4), remoteTiming(5), noSignalLocalandRemoteTiming(6)}read-onlycurrent
channelALineCode
OBJECT-TYPE
The line code setting of the telecoms interface. This must match the setting of the device connected to this interface
1.3.6.1.4.1.17713.6.7.4INTEGER {aMI(0), b8ZSHDB3(1)}read-onlycurrent
channelBLineCode
OBJECT-TYPE
The line code setting of the telecoms interface. This must match the setting of the device connected to this interface
1.3.6.1.4.1.17713.6.7.5INTEGER {aMI(0), b8ZSHDB3(1)}read-onlycurrent
channelACableLength
OBJECT-TYPE
The length of the cable connected to the telecoms interface, measured in feet
1.3.6.1.4.1.17713.6.7.6INTEGER {feet133(0), feet266(1), feet399(2), feet533(3), feet655(4)}read-onlycurrent
channelBCableLength
OBJECT-TYPE
The length of the cable connected to the telecoms interface, measured in feet
1.3.6.1.4.1.17713.6.7.7INTEGER {feet133(0), feet266(1), feet399(2), feet533(3), feet655(4)}read-onlycurrent
channelALoopback
OBJECT-TYPE
The loopback status of telecoms channel A. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.7.8INTEGER {none(0), copper(1), wireless(2)}read-onlycurrent
channelBLoopback
OBJECT-TYPE
The loopback status of telecoms channel B. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.7.9INTEGER {none(0), copper(1), wireless(2)}read-onlycurrent
telecomsChannelSelection
OBJECT-TYPE
Indicates which telecoms channels have been enabled. If only Channel A has been enabled, then the Channel B attributes will be ignored.
1.3.6.1.4.1.17713.6.7.10INTEGER {channelAOnly(0), channelsAandB(1)}read-onlycurrent
licence
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.8
regionCode
OBJECT-TYPE
The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted license key. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.8.1INTEGER {regionCodeInvalid(0), regionCode1(1), regionCode2(2), regionCode3(3), regionCode4(4), regionCode5(5), regionCode6(6), regionCode7(7), regionCode8(8), regionCode9(9), regionCode10(10), regionCode11(11), regionCode12(12), regionCode13(13), regionCode14(14), regionCode15(15), regionCode16(16), regionCode17(17), regionCode18(18), regionCode19(19), regionCode20(20), regionCode21(21), regionCode22(22), regionCode23(23), regionCode24(24), regionCode25(25), regionCode26(26), regionCode27(27), regionCode28(28), regionCode29(29), regionCode30(30), regionCode31(31)}read-onlycurrent
productVariant
OBJECT-TYPE
The product variant
1.3.6.1.4.1.17713.6.8.2INTEGER {pTPxx400Full(0), pTPxx400Deprecated1(1), pTPxx400Deprecated2(2), pTPxx400Lite(3), spare1(4), pTPxx300(5), spare2(6), spare3(7), pTPxx500FullDeprecated(8), pTPxx500LiteDeprecated(9), pTPxx500(10), pTPxx600Lite(11), pTPxx600Full(12), spare5(13), spare6(14), pTP800(15)}read-onlycurrent
productName
OBJECT-TYPE
Name of the product variant
1.3.6.1.4.1.17713.6.8.3DisplayString (SIZE(0..63))read-onlycurrent
ethernetFiberSupport
OBJECT-TYPE
Ethernet fiber support availability on this wireless unit
1.3.6.1.4.1.17713.6.8.4INTEGER {disabled(0), enabled(1)}read-onlycurrent
frequencyVariant
OBJECT-TYPE
Frequency variant of the wireless unit
1.3.6.1.4.1.17713.6.8.5INTEGER {freq5800MHz(0), freq5400MHz(1), freq4900MHz(2), freq2500MHz(3), freq5800MHz2(4), freq5400MHz2(5), freq4500MHz(6), freq5900MHz(7), freq5200MHz(8), freq5100MHz(9), freq4800MHz(10)}read-onlycurrent
bandwidthVariant
OBJECT-TYPE
Bandwidth variant of the wireless unit
1.3.6.1.4.1.17713.6.8.6INTEGER {bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4)}read-onlycurrent
constantPowerSpectralDensity
OBJECT-TYPE
Constant power spectral density mode control
1.3.6.1.4.1.17713.6.8.7INTEGER {constant(0), fullPower(1)}read-onlycurrent
sNMPv3Enable
OBJECT-TYPE
SNMPv3 availability control
1.3.6.1.4.1.17713.6.8.9INTEGER {disabled(0), enabled(1)}read-onlycurrent
hAZLOCConfiguration
OBJECT-TYPE
The HAZLOC/ATEX Configuration of this unit. The Gas Group is configured by the license key.
1.3.6.1.4.1.17713.6.8.10INTEGER {nonHAZLOCUnit(0), gasGroupA(1), gasGroupB(2), gasGroupC(3), gasGroupD(4)}read-onlycurrent
securityLevel
OBJECT-TYPE
The maximum configurable security level
1.3.6.1.4.1.17713.6.8.11INTEGER {normal(0), fIPS(1), uCAPL(2)}read-onlycurrent
management
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.9
targetRange
OBJECT-TYPE
Initial target range used in installation +/-1, expressed in tenths of a kilometer. When Auto-Ranging this must be set to 0
1.3.6.1.4.1.17713.6.9.1INTEGER (0..2000)read-onlycurrent
rangingMode
OBJECT-TYPE
Type of ranging to use during installation, either Auto-Ranging or use a selectable Target Range
1.3.6.1.4.1.17713.6.9.2INTEGER {auto0to40km(0), auto0to100km(1), auto0to200km(2), targetRange(3)}read-onlycurrent
installStatus
OBJECT-TYPE
A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.9.3INTEGER {ok(0), wrongPeer(1)}read-onlycurrent
installArmState
OBJECT-TYPE
Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.9.4INTEGER {disarmed(0), armed(1)}read-onlycurrent
tFTPServerIPAddress
OBJECT-TYPE
IP address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved
1.3.6.1.4.1.17713.6.9.5IpAddressread-writecurrent
tFTPServerPortNumber
OBJECT-TYPE
The port number of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved
1.3.6.1.4.1.17713.6.9.6INTEGER (0..65535)read-writecurrent
tFTPSoftwareUpgradeFileName
OBJECT-TYPE
Filename of the Software Upgrade to be loaded from the TFTP Server
1.3.6.1.4.1.17713.6.9.7DisplayString (SIZE(0..127))read-writecurrent
tFTPStartSoftwareUpgrade
OBJECT-TYPE
Write '1' to this attribute to start the TFTP software upgrade process. The attribute will be reset to 0 when the upgrade process has finished. Continuing with the software upgrade will cause spectrum management (DSO) channel metrics collection to stop. The wireless unit will no longer search for the optimal operational radio channel. The performance of this wireless link may deterioate over time. If operating in a region where RADAR detection is mandatory you must complete the software upgrade and reboot the unit. Channel metrics collection will only be restarted after the wireless unit has been rebooted
1.3.6.1.4.1.17713.6.9.8Integer32read-writecurrent
tFTPSoftwareUpgradeStatus
OBJECT-TYPE
The current status of the TFTP Software upgrade process
1.3.6.1.4.1.17713.6.9.9INTEGER {idle(0), uploadinprogress(1), uploadsuccessfulprogrammingFLASH(2), upgradesuccessfulreboottorunthenewsoftwareimage(3), upgradefailed(4)}read-onlycurrent
tFTPSoftwareUpgradeStatusText
OBJECT-TYPE
Descriptive text describing the status of the TFTP Software upgrade process, including any error details
1.3.6.1.4.1.17713.6.9.10DisplayString (SIZE(0..127))read-onlycurrent
tFTPSoftwareUpgradeStatusAdditionalText
OBJECT-TYPE
Any additional text describing the status of the TFTP Software upgrade process, including any error details
1.3.6.1.4.1.17713.6.9.11DisplayString (SIZE(0..127))read-onlycurrent
hTTPAccessEnabled
OBJECT-TYPE
This controls whether or not HTTP access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTP port. Remote management via HTTPS is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)
1.3.6.1.4.1.17713.6.9.12INTEGER {no(0), yes(1)}read-writecurrent
telnetAccessEnabled
OBJECT-TYPE
This controls whether or not Telnet access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the TELNET port. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Disabled)
1.3.6.1.4.1.17713.6.9.13INTEGER {no(0), yes(1)}read-writecurrent
hTTPPortNumber
OBJECT-TYPE
This controls the port number for HTTP access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 80)
1.3.6.1.4.1.17713.6.9.14INTEGER (0..65535)read-writecurrent
hTTPSPortNumber
OBJECT-TYPE
This controls the port number for HTTPS access. A value of zero will use the default port number. Availability of HTTPS is controlled via the License Key. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 443)
1.3.6.1.4.1.17713.6.9.15INTEGER (0..65535)read-writecurrent
telnetPortNumber
OBJECT-TYPE
This controls the port number for TELNET access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 23)
1.3.6.1.4.1.17713.6.9.16INTEGER (0..65535)read-writecurrent
hTTPSAccessEnabled
OBJECT-TYPE
This controls whether or not HTTPS access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTPS port. Remote management via HTTP is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)
1.3.6.1.4.1.17713.6.9.17INTEGER {no(0), yes(1)}read-writecurrent
tFTPServerInternetAddressType
OBJECT-TYPE
The type of Internet address specified by the associated tFTPServerInternetAddress.
1.3.6.1.4.1.17713.6.9.18INTEGER {unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16)}read-onlycurrent
tFTPServerInternetAddress
OBJECT-TYPE
INET address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved
1.3.6.1.4.1.17713.6.9.19InetAddressread-writecurrent
phyControl
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.10
linkSymmetry
OBJECT-TYPE
Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load.
1.3.6.1.4.1.17713.6.10.1INTEGER {symmetryAdaptive(0), symmetry2to1(1), symmetry1to1(2), symmetry1to2(3)}read-onlycurrent
linkModeOptimisation
OBJECT-TYPE
Optimises the wireless link behavior for the type of traffic to be carried. In 'IP Traffic' mode, the wireless link will minimise transmission errors by automatically adapting the modulation mode. In 'TDM Traffic' mode, the wireless link will minimise transmission latency and preserve throughput by maintaining a higher modulation mode in the presence of a limited number of errors. The 'TDM Traffic' mode is recommended for E1/T1 applications and connectionless protocols.
1.3.6.1.4.1.17713.6.10.2INTEGER {iPTraffic(0), tDMTraffic(1)}read-onlycurrent
userConfiguredMaxModulationMode
OBJECT-TYPE
The maximum receive modulation mode controls the MAX mode used for adaptive modulation. NOTE: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard
1.3.6.1.4.1.17713.6.10.3INTEGER {modBpsk63percent(0), modQpsk63percent(1), modQpsk87percent(2), mod16qam63percent(3), mod16qam87percent(4), mod64qam75percent(5), mod64qam92percent(6), mod256qam81percent(7)}read-writecurrent
remoteMaximumTransmitPower
OBJECT-TYPE
Maximum transmit power the remote wireless unit is permitted to use when establishing and maintaining the wireless link
1.3.6.1.4.1.17713.6.10.4INTEGER (-15..27)read-onlycurrent
txColorCode
OBJECT-TYPE
Transmit Color Code. This attribute need only be considered when the unit is installed in a network of PTP600 units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Rx Color Code parameter at the far end of the link.
1.3.6.1.4.1.17713.6.10.5INTEGER {a(0), b(1), c(2), d(3), e(4)}read-onlycurrent
rxColorCode
OBJECT-TYPE
Receive Color Code. This attribute need only be considered when the unit is installed in a network of PTP600 units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Tx Color Code parameter at the far end of the link.
1.3.6.1.4.1.17713.6.10.6INTEGER {a(0), b(1), c(2), d(3), e(4)}read-onlycurrent
automaticTxPowerControl
OBJECT-TYPE
When enabled, the transmit power of the local end is automatically adjusted to maintain a configurable target receive signal level at the remote end of the link. When set to Enable with initial estimate, the Slave estimates the optional transmit power before it responds to the Master.
1.3.6.1.4.1.17713.6.10.8INTEGER {disabled(0), enabled(1), enabledwithinitialestimate(2)}read-onlycurrent
remoteRxTargetPower
OBJECT-TYPE
This is the target receive level for the end of the link which is remote from the end being configured. When Automatic Power Control is enabled, the transmit power of the local end is automatically adjusted in order to maintain the receive signal level at the remote end within a range centered on this value
1.3.6.1.4.1.17713.6.10.9INTEGER (-600..-400)read-onlycurrent
phyStatus
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.12
receivePower
OBJECT-TYPE
Receive power expressed in tenths of a dBm
1.3.6.1.4.1.17713.6.12.1Integer32read-onlycurrent
vectorError
OBJECT-TYPE
The vector error measurement compares the received signal's IQ modulation characteristics to an ideal signal to determine the composite error vector magnitude. The value represented by this attribute is the average vector error over the previous second expressed in tenths of a dB
1.3.6.1.4.1.17713.6.12.2Integer32read-onlycurrent
transmitPower
OBJECT-TYPE
Transmit power expressed in tenths of a dBm
1.3.6.1.4.1.17713.6.12.3Integer32read-onlycurrent
range
OBJECT-TYPE
Distance between the two peer wireless units expressed in tenths of a kilometer
1.3.6.1.4.1.17713.6.12.4Integer32read-onlycurrent
linkLoss
OBJECT-TYPE
The wireless link loss expressed in tenths of a dB
1.3.6.1.4.1.17713.6.12.5INTEGER (-500..500)read-onlycurrent
receiveChannel
OBJECT-TYPE
Current active receive channel
1.3.6.1.4.1.17713.6.12.6INTEGER (0..63)read-onlycurrent
transmitChannel
OBJECT-TYPE
Current active transmit channel
1.3.6.1.4.1.17713.6.12.7INTEGER (0..63)read-onlycurrent
receiveModulationMode
OBJECT-TYPE
Current active receive modulation mode
1.3.6.1.4.1.17713.6.12.8INTEGER {modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24)}read-onlycurrent
transmitModulationMode
OBJECT-TYPE
Current active transmit modulation mode
1.3.6.1.4.1.17713.6.12.9INTEGER {modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24)}read-onlycurrent
receiveFreqMHz
OBJECT-TYPE
Current receive frequency expressed in integer MHz
1.3.6.1.4.1.17713.6.12.11INTEGER (0..5925)read-onlycurrent
transmitFreqMHz
OBJECT-TYPE
Current transmit frequency expressed in integer MHz
1.3.6.1.4.1.17713.6.12.12INTEGER (0..5925)read-onlycurrent
signalStrengthRatio
OBJECT-TYPE
Signal strength ratio (Vertical / Horizontal) : the number of dB larger the Vertical antenna input is than the Horizontal antenna input expressed in tenths of a dB
1.3.6.1.4.1.17713.6.12.13Integer32read-onlycurrent
receiveFreqKHz
OBJECT-TYPE
Current receive frequency expressed as KHz
1.3.6.1.4.1.17713.6.12.14INTEGER (0..5925000)read-onlycurrent
transmitFreqKHz
OBJECT-TYPE
Current transmit frequency expressed as KHz
1.3.6.1.4.1.17713.6.12.15INTEGER (0..5925000)read-onlycurrent
searchState
OBJECT-TYPE
Search status of the wireless modem. 'Registering' means that the modem has locked to an OFDM signal, and the wireless link is up. 'Searching' means that no wireless signal has been detected. 'Acquiring' means that a wireless signal has been detected, but the modem has not locked to an OFDM signal.
1.3.6.1.4.1.17713.6.12.16INTEGER {registering(0), searching(1), acquiring(2)}read-onlycurrent
rawReceivePower
OBJECT-TYPE
Raw receive power expressed in tenths of a dBm
1.3.6.1.4.1.17713.6.12.17Integer32read-onlycurrent
alarms
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.13
unitOutOfCalibration
OBJECT-TYPE
The unit is out of calibration
1.3.6.1.4.1.17713.6.13.1INTEGER {calibrated(0), outOfCalibration(1), outOfCalibrationPAsShutdown(2)}read-onlycurrent
incompatibleRegionCodes
OBJECT-TYPE
The master and slave units have incompatible region codes. NB: Both units must have compatible license keys
1.3.6.1.4.1.17713.6.13.4INTEGER {ok(0), incompatibleLicenceKeys(1)}read-onlycurrent
noWirelessChannelAvailable
OBJECT-TYPE
Spectrum Management was unable to locate a suitable wireless channel to operate on
1.3.6.1.4.1.17713.6.13.5INTEGER {ok(0), noWirelessChannelAvailable(1)}read-onlycurrent
wirelessLinkDisabledWarning
OBJECT-TYPE
The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic
1.3.6.1.4.1.17713.6.13.6INTEGER {ok(0), disabledBySNMPifAdminStatus(1)}read-onlycurrent
dataPortDisabledWarning
OBJECT-TYPE
The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic
1.3.6.1.4.1.17713.6.13.7INTEGER {ok(0), disabledBySNMPifAdminStatus(1)}read-onlycurrent
dataPortFiberStatus
OBJECT-TYPE
If the fiber link is not OK, there are three possible causes: Either the fiber link has been installed but disabled (because the license key does not include fiber support), the link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), or the link could not be established and LOS is detected (i.e. no optical carrier is detected). NB: a change of status may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.13.8INTEGER {ok(0), installedFiberNotLicensed(1), fiberLinkNotEstablishedButLOSNotDetected(2), fiberLinkNotEstablishedAndLOSDetected(3)}read-onlycurrent
dataPortConfigurationMismatch
OBJECT-TYPE
The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch
1.3.6.1.4.1.17713.6.13.9INTEGER {noError(0), mismatchDetected(1)}read-onlycurrent
incompatibleMasterAndSlave
OBJECT-TYPE
A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.13.10INTEGER {ok(0), incompatibleProductVariants(1), differentSoftwareVersionsRunning(2)}read-onlycurrent
tDDSynchronizationStatus
OBJECT-TYPE
An alarm value (displayed in red) indicates that one of the following conditions has not been met (i) An external timing system is connected or internal timing has been configured. (ii) The timing system is providing a useable reference. (iii) The ODU is locked to this reference.
1.3.6.1.4.1.17713.6.13.11INTEGER {locked(0), holdover(1), holdoverNotConnected(2), acquiringLock(3), noTimingReference(4), timingSystemNotConnected(5), initialising(6), clusterTimingMaster(7), tDDSyncNotActive(8)}read-onlycurrent
managementPortDisabledWarning
OBJECT-TYPE
The SNMP ifAdminStatus of the out-of-band management interface has disabled Ethernet traffic
1.3.6.1.4.1.17713.6.13.12INTEGER {ok(0), disabledBySNMPifAdminStatus(1)}read-onlycurrent
tDDSynchronizationAlarm
OBJECT-TYPE
Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired.
1.3.6.1.4.1.17713.6.13.13INTEGER {ok(0), notSynchronized(1), timingSystemFailure(2)}read-onlycurrent
linkModeOptimizationMismatch
OBJECT-TYPE
The remote node of this link has been configured with a different link mode optimization
1.3.6.1.4.1.17713.6.13.14INTEGER {ok(0), linkModeOptimizationMismatch(1)}read-onlycurrent
managementPortConfigurationMismatch
OBJECT-TYPE
The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured.
1.3.6.1.4.1.17713.6.13.15INTEGER {noError(0), mismatchDetected(1)}read-onlycurrent
secureModeAlarm
OBJECT-TYPE
The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image.
1.3.6.1.4.1.17713.6.13.16INTEGER {secureModeIsActive(0), secureModeIsNotConfigured(1), secureModeIsConfiguredButNotActive(2), secureModeIsNotSupported(3)}read-onlycurrent
ethernetBridgingStatusAlarm
OBJECT-TYPE
Ethernet traffic bridging is disabled because the wireless link is not operating at the configured Lowest Ethernet Modulation Mode
1.3.6.1.4.1.17713.6.13.17INTEGER {ethernetBridgingEnabled(0), ethernetBridgingDisabled(1)}read-onlycurrent
smtp
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.15
sMTPEmailAlert
OBJECT-TYPE
Simple Mail Transfer Protocol is used to send equipment alerts via email to a specified email address
1.3.6.1.4.1.17713.6.15.1INTEGER {disabled(0), enabled(1)}read-writecurrent
sMTPServerIPAddress
OBJECT-TYPE
IP address of the SMTP server
1.3.6.1.4.1.17713.6.15.2IpAddressread-writecurrent
sMTPServerPortNumber
OBJECT-TYPE
Port number of the SMTP server
1.3.6.1.4.1.17713.6.15.3INTEGER (0..65535)read-writecurrent
sMTPSourceEmailAddress
OBJECT-TYPE
The 'from' email address used when constructing the automatically generated e-mail message
1.3.6.1.4.1.17713.6.15.4DisplayString (SIZE(0..63))read-writecurrent
sMTPDestinationEmailAddress
OBJECT-TYPE
The 'to' email address used when constructing the automatically generated e-mail message
1.3.6.1.4.1.17713.6.15.5DisplayString (SIZE(0..63))read-writecurrent
sMTPEnabledMessages
OBJECT-TYPE
This controls which SMTP messages the unit will send
1.3.6.1.4.1.17713.6.15.6Bits {telecomsChannelUpDown(1), managementPortUpDown(2), dataPortUpDown(3), enabledDiagnosticAlarms(4), dFSImpulseInterference(5), channelChange(6), wirelessLinkUpDown(7)}read-writecurrent
sMTPServerInternetAddressType
OBJECT-TYPE
The type of Internet address specified by the associated sMTPServerInternetAddress.
1.3.6.1.4.1.17713.6.15.7INTEGER {unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16)}read-onlycurrent
sMTPServerInternetAddress
OBJECT-TYPE
Internet address of the SMTP server
1.3.6.1.4.1.17713.6.15.8InetAddressread-writecurrent
snmpControl
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.16
sNMPPortNumber
OBJECT-TYPE
The IP port number used to access the SNMP MIB (i.e. Gets and Sets) (default = 161). NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.16.1INTEGER (0..65535)read-writecurrent
sNMPCommunityString
OBJECT-TYPE
The SNMP community string. NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.16.2DisplayString (SIZE(0..63))read-writecurrent
sNMPTrapTableNumber
OBJECT-TYPE
Number of entries in the sNMPTrapTable.
1.3.6.1.4.1.17713.6.16.3INTEGER (2)read-onlycurrent
sNMPTrapTable
OBJECT-TYPE
SNMP trap configuration table.
1.3.6.1.4.1.17713.6.16.4not-accessiblecurrent
sNMPTrapTableEntry
OBJECT-TYPE
Table SNMPTrapTable
1.3.6.1.4.1.17713.6.16.4.1not-accessiblecurrent
sNMPTrapTableIndex
OBJECT-TYPE
SNMP trap value, used to index the SNMPTrapTable.
1.3.6.1.4.1.17713.6.16.4.1.1INTEGER (1..2)not-accessiblecurrent
sNMPTrapIPAddress
OBJECT-TYPE
The IP address to which all SNMP Traps are sent. NB: A system reboot is required to activate changes to this attribute.
1.3.6.1.4.1.17713.6.16.4.1.2IpAddressread-writecurrent
sNMPTrapPortNumber
OBJECT-TYPE
Destination port for SNMP Traps (default=162). NB: A system reboot is required to activate changes to this attribute.
1.3.6.1.4.1.17713.6.16.4.1.3INTEGER (0..65535)read-writecurrent
sNMPTrapInternetAddressType
OBJECT-TYPE
The type of Internet address specified by the associated sNMPTrapInternetAddress.
1.3.6.1.4.1.17713.6.16.4.1.4INTEGER {unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16)}read-onlycurrent
sNMPTrapInternetAddress
OBJECT-TYPE
The Internet address to which all SNMP Traps are sent.
1.3.6.1.4.1.17713.6.16.4.1.5InetAddressread-writecurrent
sNMPTrapReceiverEnabled
OBJECT-TYPE
A value of 0 disables the sending of SNMP trap to corresponding receiver. A value of 1 enables the sending of SNMP trap to corresponding receiver.
1.3.6.1.4.1.17713.6.16.4.1.6INTEGER {disabled(0), enabled(1)}read-writecurrent
sNMPTrapVersion
OBJECT-TYPE
The SNMP protocol version to use for SNMP Traps. NB: A system reboot is required to activate changes to this attribute
1.3.6.1.4.1.17713.6.16.5INTEGER {v1(0), v2c(1)}read-writecurrent
sNMPEnabledTraps
OBJECT-TYPE
This controls which SNMP Traps the unit will send
1.3.6.1.4.1.17713.6.16.6Bits {managementPortUpDown(0), dataPortUpDown(1), authenticationFailure(2), enabledDiagnosticAlarms(3), dFSImpulseInterference(4), channelChange(5), wirelessLinkUpDown(6), coldStart(7), telecomsChannelUpDown(15)}read-writecurrent
enabledDiagnosticAlarms
OBJECT-TYPE
Controls which individual diagnostic alarms are enabled. The unit may be configured to generate SNMP traps and/or SMTP email alerts for these enabled alarms by selecting 'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps' and/or 'SMTP Enabled Messages' attributes
1.3.6.1.4.1.17713.6.16.7Bits {incompatibleMasterAndSlave(0), incompatibleRegionCodes(1), unknown6(2), unknown5(3), unitOutOfCalibration(4), installArmState(5), installStatus(6), regionCode(7), telecomsChannelAStatus(8), dataPortFiberStatus(9), dataPortStatus(10), dataPortDisabledWarning(11), wirelessLinkDisabledWarning(12), sNTPSynchronizationFailed(13), noWirelessChannelAvailable(14), dataPortConfigurationMismatch(15), syslogDisabledWarning(16), linkModeOptimizationMismatch(17), managementPortStatus(18), managementPortDisabledWarning(19), tDDSynchronizationAlarm(20), telecomsChannelBLoopback(21), telecomsChannelALoopback(22), telecomsChannelBStatus(23), ethernetBridgingStatus(26), secureMode(27), syslogClientDisabledWarning(28), managementPortConfigurationMismatch(29), syslogLocalWrapped(30), syslogLocalNearlyFull(31)}read-writecurrent
sNMPSendAllTrapsAtStartup
OBJECT-TYPE
Controls whether or not all the enabled traps and alarms (including cleared alarms) are reported at start-up.
1.3.6.1.4.1.17713.6.16.8INTEGER {disabled(0), enabled(1)}read-writecurrent
sntp
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.17
sNTPState
OBJECT-TYPE
SNTP control state
1.3.6.1.4.1.17713.6.17.1INTEGER {disabled(0), enabled(1)}read-writecurrent
sNTPPollInterval
OBJECT-TYPE
The SNTP server polling interval
1.3.6.1.4.1.17713.6.17.4INTEGER (60..43200)read-writecurrent
sNTPSync
OBJECT-TYPE
If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP
1.3.6.1.4.1.17713.6.17.5INTEGER {noSync(0), inSync(1)}read-onlycurrent
sNTPLastSync
OBJECT-TYPE
Last SNTP sync time
1.3.6.1.4.1.17713.6.17.6Integer32read-onlycurrent
systemClock
OBJECT-TYPE
System clock presented as local time
1.3.6.1.4.1.17713.6.17.7Integer32read-onlycurrent
timeZone
OBJECT-TYPE
Time zone offsets from Greenwich Mean Time (GMT)
1.3.6.1.4.1.17713.6.17.8INTEGER {gmtMinus1200(0), gmtMinus1130(1), gmtMinus1100(2), gmtMinus1030(3), gmtMinus1000(4), gmtMinus0930(5), gmtMinus0900(6), gmtMinus0830(7), gmtMinus0800(8), gmtMinus0730(9), gmtMinus0700(10), gmtMinus0630(11), gmtMinus0600(12), gmtMinus0530(13), gmtMinus0500(14), gmtMinus0430(15), gmtMinus0400(16), gmtMinus0330(17), gmtMinus0300(18), gmtMinus0230(19), gmtMinus0200(20), gmtMinus0130(21), gmtMinus0100(22), gmtMinus0030(23), gmtZero(24), gmtPlus0030(25), gmtPlus0100(26), gmtPlus0130(27), gmtPlus0200(28), gmtPlus0230(29), gmtPlus0300(30), gmtPlus0330(31), gmtPlus0400(32), gmtPlus0430(33), gmtPlus0500(34), gmtPlus0530(35), gmtPlus0600(36), gmtPlus0630(37), gmtPlus0700(38), gmtPlus0730(39), gmtPlus0800(40), gmtPlus0830(41), gmtPlus0900(42), gmtPlus0930(43), gmtPlus1000(44), gmtPlus1030(45), gmtPlus1100(46), gmtPlus1130(47), gmtPlus1200(48), gmtPlus1230(49), gmtPlus1300(50)}read-writecurrent
daylightSaving
OBJECT-TYPE
Daylight Saving Time
1.3.6.1.4.1.17713.6.17.9INTEGER {disabled(0), enabled(1)}read-writecurrent
sNTPPrimaryServer
OBJECT-TYPE
Specifies the primary SNTP server, determining the order in which the servers are tried.
1.3.6.1.4.1.17713.6.17.10INTEGER {server1(0), server2(1)}read-writecurrent
sNTPPrimaryServerDeadTime
OBJECT-TYPE
Time (in seconds) to wait before retrying communications with an unresponsive primary SNTP server. Setting the value to 0 disables the timer.
1.3.6.1.4.1.17713.6.17.11INTEGER (0..86400)read-writecurrent
sNTPServerRetries
OBJECT-TYPE
Number of times the PTP will retry after an SNTP server fails to respond.
1.3.6.1.4.1.17713.6.17.12INTEGER (0..10)read-writecurrent
sNTPServerTimeout
OBJECT-TYPE
Time (in seconds) the PTP will wait for a response from an SNTP server.
1.3.6.1.4.1.17713.6.17.13INTEGER (1..15)read-writecurrent
sNTPServerTableNumber
OBJECT-TYPE
Number of entries in the SNTPServerTable.
1.3.6.1.4.1.17713.6.17.14INTEGER (2)read-onlycurrent
sNTPServerTable
OBJECT-TYPE
1.3.6.1.4.1.17713.6.17.15not-accessiblecurrent
sNTPServerTableEntry
OBJECT-TYPE
Table SNTPServerTable
1.3.6.1.4.1.17713.6.17.15.1not-accessiblecurrent
sNTPServerTableIndex
OBJECT-TYPE
Index range for the SNTPServerTable.
1.3.6.1.4.1.17713.6.17.15.1.1INTEGER (1..2)not-accessiblecurrent
sNTPServerIPAddress
OBJECT-TYPE
The IP address of a valid SNTP server
1.3.6.1.4.1.17713.6.17.15.1.2IpAddressread-writecurrent
sNTPServerPortNumber
OBJECT-TYPE
The IP port number of the SNTP server. Defaults to port 123.
1.3.6.1.4.1.17713.6.17.15.1.3INTEGER (0..65535)read-writecurrent
sNTPServerStatus
OBJECT-TYPE
Status message reflecting the result of communications with the SNTP server when last polled
1.3.6.1.4.1.17713.6.17.15.1.4DisplayString (SIZE(0..127))read-onlycurrent
sNTPServerInternetAddressType
OBJECT-TYPE
The type of Internet address specified by the associated sNTPServerInternetAddress.
1.3.6.1.4.1.17713.6.17.15.1.5INTEGER {unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16)}read-onlycurrent
sNTPServerInternetAddress
OBJECT-TYPE
The Internet address of a valid SNTP server
1.3.6.1.4.1.17713.6.17.15.1.6InetAddressread-writecurrent
reset
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.18
systemReset
OBJECT-TYPE
Setting this attribute to '1' will cause a system reboot. NB: a system reboot will apply any pending new settings held in memory
1.3.6.1.4.1.17713.6.18.1INTEGER {running(0), consoleReboot(1)}read-writecurrent
versions
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.19
softwareVersion
OBJECT-TYPE
Current software version
1.3.6.1.4.1.17713.6.19.1DisplayString (SIZE(0..63))read-onlycurrent
hardwareVersion
OBJECT-TYPE
Hardware platform version
1.3.6.1.4.1.17713.6.19.2DisplayString (SIZE(0..63))read-onlycurrent
secondarySoftwareVersion
OBJECT-TYPE
Secondary software version, used when the primary software image is invalid or erased
1.3.6.1.4.1.17713.6.19.3DisplayString (SIZE(0..63))read-onlycurrent
bootVersion
OBJECT-TYPE
Boot code software version
1.3.6.1.4.1.17713.6.19.4DisplayString (SIZE(0..63))read-onlycurrent
pubStats
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.20
receiveDataRate
OBJECT-TYPE
Average data rate over the last one second interval (kbps)
1.3.6.1.4.1.17713.6.20.1Integer32read-onlycurrent
transmitDataRate
OBJECT-TYPE
Average data rate over the last one second interval (kbps)
1.3.6.1.4.1.17713.6.20.2Integer32read-onlycurrent
aggregateDataRate
OBJECT-TYPE
Average data rate over the last one second interval (kbps)
1.3.6.1.4.1.17713.6.20.3Integer32read-onlycurrent
wirelessLinkAvailability
OBJECT-TYPE
Link availability calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision
1.3.6.1.4.1.17713.6.20.4INTEGER (0..1000000)read-onlycurrent
wirelessLinkStatus
OBJECT-TYPE
Current status of the wireless link
1.3.6.1.4.1.17713.6.20.5INTEGER {up(0), registering(1), searching(2), acquiring(3), radarCAC(4), initialising(5)}read-onlycurrent
byteErrorRatio
OBJECT-TYPE
Reciprocal of the byte error ratio calculated since the last reset of the system counters
1.3.6.1.4.1.17713.6.20.6Integer32read-onlycurrent
receiveModulationModeDetail
OBJECT-TYPE
The reason for the current receive modulation mode
1.3.6.1.4.1.17713.6.20.7INTEGER {runningAtMaximumReceiveMode(0), runningAtUserConfiguredMaxModulationMode(1), restrictedBecauseInstallationIsArmed(2), restrictedBecauseOfByteErrorsOnTheWirelessLink(3), restrictedBecauseTheLinkParametersAreUpdating(4), restrictedBecauseChannelChangeIsInProgress(5), restrictedDueToTheLowEthernetLinkSpeed(6), runningAtMaximumReceiveModeForChannelBandwidth(7), limitedByTheWirelessConditions(8)}read-onlycurrent
ethernetBridgingAvailability
OBJECT-TYPE
Link availability bridging Ethernet traffic calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision
1.3.6.1.4.1.17713.6.20.8INTEGER (0..1000000)read-onlycurrent
encryption
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.22
encryptionAlgorithm
OBJECT-TYPE
The Encryption Algorithm used by the wireless link. NB: A system reboot is required to activate changes to this attribute. NB: The same Encryption Algorithm must be configured at BOTH ends of the link for it to function correctly
1.3.6.1.4.1.17713.6.22.1INTEGER {none(0), aESRijndael(1), aES256bitRijndael(2)}read-onlycurrent
tDDControl
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.23
tDDSynchronizationMode
OBJECT-TYPE
TDD Synchronization Mode selection
1.3.6.1.4.1.17713.6.23.1INTEGER {disabled(0), enabled(1)}read-onlycurrent
syslogControl
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.24
syslogClient
OBJECT-TYPE
Enable or disable the syslog client
1.3.6.1.4.1.17713.6.24.1INTEGER {disabled(0), enabled(1)}read-onlycurrent
syslogState
OBJECT-TYPE
The syslog service has been enabled or disabled
1.3.6.1.4.1.17713.6.24.2INTEGER {disabled(0), enabled(1)}read-onlycurrent
aAAControl
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.25
userTableNumber
OBJECT-TYPE
Number of entries in the userTable
1.3.6.1.4.1.17713.6.25.1INTEGER (1..10)read-onlycurrent
userTable
OBJECT-TYPE
The User Table Control group contains objects specifically for user account management.
1.3.6.1.4.1.17713.6.25.2not-accessiblecurrent
userTableEntry
OBJECT-TYPE
Table UserTable
1.3.6.1.4.1.17713.6.25.2.1not-accessiblecurrent
userTableIndex
OBJECT-TYPE
used to index values in the userTable.
1.3.6.1.4.1.17713.6.25.2.1.1INTEGER (1..10)not-accessiblecurrent
userName
OBJECT-TYPE
User name which must be entered, along with the appropriate password, in order to gain access to the system.
1.3.6.1.4.1.17713.6.25.2.1.2OCTET STRINGread-onlycurrent
userRole
OBJECT-TYPE
Role of the selected user. A Security Officer has access to and can modify all settings. A System Administrator has access to and can modify all non-security settings. A Read Only user can view settings, but cannot make any changes.
1.3.6.1.4.1.17713.6.25.2.1.3INTEGER {readOnly(0), systemAdministrator(1), securityOfficer(2)}read-onlycurrent
userEnabled
OBJECT-TYPE
Enable / Disable the selected user
1.3.6.1.4.1.17713.6.25.2.1.4INTEGER {disabled(0), enabled(1)}read-onlycurrent
userPassword
OBJECT-TYPE
User password, which must be entered in order to gain access to the system.
1.3.6.1.4.1.17713.6.25.2.1.5OCTET STRINGread-writecurrent
supplementary
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.96
longitude
OBJECT-TYPE
The longitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function.
1.3.6.1.4.1.17713.6.96.1DisplayString (SIZE(0..19))read-writecurrent
latitude
OBJECT-TYPE
The latitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function.
1.3.6.1.4.1.17713.6.96.2DisplayString (SIZE(0..19))read-writecurrent
altitude
OBJECT-TYPE
The altitude of the unit, measured in metres. This object is set by the SNMP manager and has no internal function.
1.3.6.1.4.1.17713.6.96.3Integer32read-writecurrent
ptpGroups
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.98
ptpTraps
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.99
ptpTrapPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.17713.6.99.0

Notifications

NameOIDStatus
channelChangeTrap
NOTIFICATION-TYPE
The PTP radio has changed wireless channel. This has been caused by either i) mandatory radar avoidance, a DFS impulsive interference event will also be detected, or ii) Dynamic Spectrum Optimization, (DSO) DSO improves link performance by selecting the most appropriate transmit and receive channels with the lowest level of interference.
1.3.6.1.4.1.17713.6.99.0.1current
dfsImpulsiveInterferenceTrap
NOTIFICATION-TYPE
DFS impulsive interference detected event
1.3.6.1.4.1.17713.6.99.0.2current
dataPortStatusTrap
NOTIFICATION-TYPE
Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.3current
telecomsChannelAStatusTrap
NOTIFICATION-TYPE
Current status of telecoms channel A. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.4current
telecomsChannelBStatusTrap
NOTIFICATION-TYPE
Current status of telecoms channel B. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.5current
channelALoopbackTrap
NOTIFICATION-TYPE
The loopback status of telecoms channel A. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.6current
channelBLoopbackTrap
NOTIFICATION-TYPE
The loopback status of telecoms channel B. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.7current
regionCodeTrap
NOTIFICATION-TYPE
The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted license key. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.8current
installStatusTrap
NOTIFICATION-TYPE
A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.9current
installArmStateTrap
NOTIFICATION-TYPE
Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.10current
unitOutOfCalibrationTrap
NOTIFICATION-TYPE
The unit is out of calibration
1.3.6.1.4.1.17713.6.99.0.11current
incompatibleRegionCodesTrap
NOTIFICATION-TYPE
The master and slave units have incompatible region codes. NB: Both units must have compatible license keys
1.3.6.1.4.1.17713.6.99.0.14current
noWirelessChannelAvailableTrap
NOTIFICATION-TYPE
Spectrum Management was unable to locate a suitable wireless channel to operate on
1.3.6.1.4.1.17713.6.99.0.15current
wirelessLinkDisabledWarningTrap
NOTIFICATION-TYPE
The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic
1.3.6.1.4.1.17713.6.99.0.16current
dataPortDisabledWarningTrap
NOTIFICATION-TYPE
The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic
1.3.6.1.4.1.17713.6.99.0.17current
dataPortFiberStatusTrap
NOTIFICATION-TYPE
If the fiber link is not OK, there are three possible causes: Either the fiber link has been installed but disabled (because the license key does not include fiber support), the link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), or the link could not be established and LOS is detected (i.e. no optical carrier is detected). NB: a change of status may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.18current
dataPortConfigurationMismatchTrap
NOTIFICATION-TYPE
The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch
1.3.6.1.4.1.17713.6.99.0.19current
incompatibleMasterAndSlaveTrap
NOTIFICATION-TYPE
A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.20current
sNTPSyncTrap
NOTIFICATION-TYPE
If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP
1.3.6.1.4.1.17713.6.99.0.21current
tDDSynchronizationAlarmTrap
NOTIFICATION-TYPE
Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired.
1.3.6.1.4.1.17713.6.99.0.22current
managementPortStatusTrap
NOTIFICATION-TYPE
Current status of the out-of-band management link. NB: a change of state may generate an SNMP trap and/or SMTP email alert
1.3.6.1.4.1.17713.6.99.0.23current
managementPortDisabledWarningTrap
NOTIFICATION-TYPE
The SNMP ifAdminStatus of the out-of-band management interface has disabled Ethernet traffic
1.3.6.1.4.1.17713.6.99.0.24current
linkModeOptimizationMismatchTrap
NOTIFICATION-TYPE
The remote node of this link has been configured with a different link mode optimization
1.3.6.1.4.1.17713.6.99.0.25current
managementPortConfigurationMismatchTrap
NOTIFICATION-TYPE
The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured.
1.3.6.1.4.1.17713.6.99.0.28current
syslogStateTrap
NOTIFICATION-TYPE
The syslog service has been enabled or disabled
1.3.6.1.4.1.17713.6.99.0.30current
syslogLocalNearlyFullTrap
NOTIFICATION-TYPE
The syslog local log is nearly full (90%)
1.3.6.1.4.1.17713.6.99.0.31current
syslogLocalWrappedTrap
NOTIFICATION-TYPE
The syslog local log has wrapped
1.3.6.1.4.1.17713.6.99.0.32current
syslogClientTrap
NOTIFICATION-TYPE
Enable or disable the syslog client
1.3.6.1.4.1.17713.6.99.0.33current
secureModeAlarmTrap
NOTIFICATION-TYPE
The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image.
1.3.6.1.4.1.17713.6.99.0.34current
ethernetBridgingStatusAlarmTrap
NOTIFICATION-TYPE
Ethernet traffic bridging is disabled because the wireless link is not operating at the configured Lowest Ethernet Modulation Mode
1.3.6.1.4.1.17713.6.99.0.35current

Conformance

NameOIDStatus
ptpCompliance
MODULE-COMPLIANCE
The compliance statement for the Cambium PTP MIB
1.3.6.1.4.1.17713.6.97current
dfsGroup
OBJECT-GROUP
The dfs object group.
1.3.6.1.4.1.17713.6.98.3current
bridgeGroup
OBJECT-GROUP
The bridge object group.
1.3.6.1.4.1.17713.6.98.4current
configurationGroup
OBJECT-GROUP
The configuration object group.
1.3.6.1.4.1.17713.6.98.5current
ethernetGroup
OBJECT-GROUP
The ethernet object group.
1.3.6.1.4.1.17713.6.98.6current
telecomGroup
OBJECT-GROUP
The telecom object group.
1.3.6.1.4.1.17713.6.98.7current
licenceGroup
OBJECT-GROUP
The licence object group.
1.3.6.1.4.1.17713.6.98.8current
managementGroup
OBJECT-GROUP
The management object group.
1.3.6.1.4.1.17713.6.98.9current
phyControlGroup
OBJECT-GROUP
The phyControl object group.
1.3.6.1.4.1.17713.6.98.10current
phyStatusGroup
OBJECT-GROUP
The phyStatus object group.
1.3.6.1.4.1.17713.6.98.12current
alarmsGroup
OBJECT-GROUP
The alarms object group.
1.3.6.1.4.1.17713.6.98.13current
smtpGroup
OBJECT-GROUP
The smtp object group.
1.3.6.1.4.1.17713.6.98.15current
snmpControlGroup
OBJECT-GROUP
The snmpControl object group.
1.3.6.1.4.1.17713.6.98.16current
sntpGroup
OBJECT-GROUP
The sntp object group.
1.3.6.1.4.1.17713.6.98.17current
resetGroup
OBJECT-GROUP
The reset object group.
1.3.6.1.4.1.17713.6.98.18current
versionsGroup
OBJECT-GROUP
The versions object group.
1.3.6.1.4.1.17713.6.98.19current
pubStatsGroup
OBJECT-GROUP
The pubStats object group.
1.3.6.1.4.1.17713.6.98.20current
encryptionGroup
OBJECT-GROUP
The encryption object group.
1.3.6.1.4.1.17713.6.98.22current
tDDControlGroup
OBJECT-GROUP
The tDDControl object group.
1.3.6.1.4.1.17713.6.98.23current
syslogControlGroup
OBJECT-GROUP
The syslogControl object group.
1.3.6.1.4.1.17713.6.98.24current
aAAControlGroup
OBJECT-GROUP
The aAAControl object group.
1.3.6.1.4.1.17713.6.98.25current
supplementaryGroup
OBJECT-GROUP
The supplementary object group.
1.3.6.1.4.1.17713.6.98.96current
notificationsGroup
NOTIFICATION-GROUP
The notifications group.
1.3.6.1.4.1.17713.6.98.99current