MIBs Depot

Baytech-MIB-401-4

Registered at
1.3.6.1.4.1.4779
Namespace
baytech
Source file
Baytech-MIB-401-4
Digest
sha256:6ea703efdfc53c6fa128819a4633a86a113de5daf161ad8b1500c3507c88a96f

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

Baytech-MIB-401-4
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
baytech
OBJECT-IDENTITY
1.3.6.1.4.1.4779
btadevices
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1
sBTAIdent
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.1
sBTAIdentFirmwareRev
OBJECT-TYPE
An 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory.
1.3.6.1.4.1.4779.1.1.1DisplayStringread-onlymandatory
sBTAIdentSerialNumber
OBJECT-TYPE
A number identifying the serial number of the DS72. This value is set at the factory.
1.3.6.1.4.1.4779.1.1.2INTEGERread-onlymandatory
sBTAIdentUnitName
OBJECT-TYPE
A 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72.
1.3.6.1.4.1.4779.1.1.3DisplayString (SIZE(64))read-writemandatory
sBTANetworkConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.2
sBTANetworkConfigBootpEnable
OBJECT-TYPE
Enables/disables bootp. Bootp will not take effect until the unit is reseted.
1.3.6.1.4.1.4779.1.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigDHCPEnable
OBJECT-TYPE
Enables/disables DHCP. DHCP will not take effect until the unit is reseted.
1.3.6.1.4.1.4779.1.2.2INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigSSHEnable
OBJECT-TYPE
Enables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted.
1.3.6.1.4.1.4779.1.2.3INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigTelnetEnable
OBJECT-TYPE
Enables/disables telnet.
1.3.6.1.4.1.4779.1.2.4INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigActivityTimeout
OBJECT-TYPE
A value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Default is 0.
1.3.6.1.4.1.4779.1.2.5INTEGERread-writemandatory
sBTANetworkConfigDirectConnEnable
OBJECT-TYPE
Enables/disables direct port connection upon login.
1.3.6.1.4.1.4779.1.2.6INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigSNMP
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.2.8
sBTANetworkConfigSNMPReadOnlyCommunity
OBJECT-TYPE
The community name to use for read only access. Maximum len 16 bytes.
1.3.6.1.4.1.4779.1.2.8.1DisplayStringread-writemandatory
sBTANetworkConfigSNMPReadWriteCommunity
OBJECT-TYPE
The community name to use for read-write access. Maximum len 16 bytes.
1.3.6.1.4.1.4779.1.2.8.2DisplayStringread-writemandatory
sBTANetworkConfigSNMPNumTrapReceivers
OBJECT-TYPE
The maximum number of managers to send traps to. Currently 4.
1.3.6.1.4.1.4779.1.2.8.3INTEGERread-onlymandatory
sBTANetworkConfigSNMPTrapReceiverTable
OBJECT-TYPE
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
1.3.6.1.4.1.4779.1.2.8.4not-accessiblemandatory
sBTANetworkConfigSNMPTrapReceiverEntry
OBJECT-TYPE
Table of managers to send traps to.
1.3.6.1.4.1.4779.1.2.8.4.1not-accessiblemandatory
trapIndex
OBJECT-TYPE
The index to a trap receiver entry.
1.3.6.1.4.1.4779.1.2.8.4.1.1INTEGERread-onlymandatory
receiverAddress
OBJECT-TYPE
The IP address of the manager to send traps to.
1.3.6.1.4.1.4779.1.2.8.4.1.2IpAddressread-writemandatory
sBTANetworkConfigRadius
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.2.9
sBTANetworkConfigRadiusEnable
OBJECT-TYPE
Enables / disables RADIUS telnet logins.
1.3.6.1.4.1.4779.1.2.9.1INTEGER {disable(0), enable(1)}read-writemandatory
sBTANetworkConfigRadiusPrimaryServer
OBJECT-TYPE
Ip address of the primary RADIUS server.
1.3.6.1.4.1.4779.1.2.9.2IpAddressread-writemandatory
sBTANetworkConfigRadiusSecondaryServer
OBJECT-TYPE
Ip address of the back-up RADIUS server.
1.3.6.1.4.1.4779.1.2.9.3IpAddressread-writemandatory
sBTANetworkConfigRadiusLocalLogin
OBJECT-TYPE
Enables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available.
1.3.6.1.4.1.4779.1.2.9.4INTEGER {disable(0), enable(1)}read-writemandatory
sBTANetworkConfigWEB
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.2.10
sBTANetworkConfigWebEnable
OBJECT-TYPE
Enables WEB.
1.3.6.1.4.1.4779.1.2.10.1INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigWebSecureEnable
OBJECT-TYPE
Enables WEB Security.
1.3.6.1.4.1.4779.1.2.10.2INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigWebLoginEnable
OBJECT-TYPE
Enables WEB Login.
1.3.6.1.4.1.4779.1.2.10.3INTEGER {disabled(0), enabled(1)}read-writemandatory
sBTANetworkConfigWebActivityTimeout
OBJECT-TYPE
A value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is 0.
1.3.6.1.4.1.4779.1.2.10.4INTEGERread-writemandatory
sBTAModules
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.3
sBTAModulesNumberOfModules
OBJECT-TYPE
Number of modules installed into the DS unit.
1.3.6.1.4.1.4779.1.3.1INTEGERread-onlymandatory
sBTAModulesModulesInstalled
OBJECT-TYPE
A character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,06 means modules 2,3,4 and 6 are installed.
1.3.6.1.4.1.4779.1.3.2DisplayStringread-onlymandatory
sBTAModulesResetModulesCmd
OBJECT-TYPE
This command is no longer supported.
1.3.6.1.4.1.4779.1.3.3INTEGERread-onlydeprecated
sBTAModulesNumberOfIntelligentModules
OBJECT-TYPE
The number of Intelligent Modules installed in the DS Unit.
1.3.6.1.4.1.4779.1.3.4INTEGERread-onlymandatory
sBTAModulesRPC
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.3.5
sBTAModulesNumberOfRPCModules
OBJECT-TYPE
The number of DS30 Modules installed in the DS Unit.
1.3.6.1.4.1.4779.1.3.5.1INTEGERread-onlymandatory
sBTAModulesRPCTable
OBJECT-TYPE
Allows for control of individual outlets and individual RPC modules.
1.3.6.1.4.1.4779.1.3.5.2not-accessiblemandatory
sBTAModulesRPCEntry
OBJECT-TYPE
The RPCs to control and get status on.
1.3.6.1.4.1.4779.1.3.5.2.1not-accessiblemandatory
sBTAModulesRPCIndex
OBJECT-TYPE
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module 3 port 1 = index 5.
1.3.6.1.4.1.4779.1.3.5.2.1.1INTEGERread-onlymandatory
sBTAModulesRPCName
OBJECT-TYPE
The name (unit id) of the rpc.
1.3.6.1.4.1.4779.1.3.5.2.1.2DisplayStringread-writemandatory
sBTAModulesRPCFirmwareVersion
OBJECT-TYPE
The firware version of the rpc.
1.3.6.1.4.1.4779.1.3.5.2.1.3DisplayStringread-onlymandatory
sBTAModulesRPCCurrent
OBJECT-TYPE
The current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.4INTEGERread-onlymandatory
sBTAModulesRPCMaxCurrent
OBJECT-TYPE
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
1.3.6.1.4.1.4779.1.3.5.2.1.5INTEGERread-writemandatory
sBTAModulesRPCVoltage
OBJECT-TYPE
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.6INTEGERread-onlymandatory
sBTAModulesRPCPower
OBJECT-TYPE
The power reading for the power strip. If power measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.7INTEGERread-onlymandatory
sBTAModulesRPCTemperature
OBJECT-TYPE
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.8INTEGERread-onlymandatory
sBTAModulesRPCRebootTimeout
OBJECT-TYPE
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
1.3.6.1.4.1.4779.1.3.5.2.1.9INTEGERread-onlymandatory
sBTAModulesRPCAllOutletsCmd
OBJECT-TYPE
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6).
1.3.6.1.4.1.4779.1.3.5.2.1.10INTEGER {off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)}read-writemandatory
sBTAModulesRPCAllOutletsStatus
OBJECT-TYPE
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
1.3.6.1.4.1.4779.1.3.5.2.1.11DisplayStringread-onlymandatory
sBTAModulesRPCCurrentAlarmThreshold
OBJECT-TYPE
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.12INTEGERread-writemandatory
sBTAModulesRPCOverVoltageThreshold
OBJECT-TYPE
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.13INTEGERread-writemandatory
sBTAModulesRPCUnderVoltageThreshold
OBJECT-TYPE
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.14INTEGERread-writemandatory
sBTAModulesRPCNumberOfOutlets
OBJECT-TYPE
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.2.1.15INTEGERread-onlymandatory
sBTAModulesRPCCircuitBreaker
OBJECT-TYPE
Status of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.2.1.16INTEGER {off(0), on(1)}read-onlymandatory
sBTAModulesRPCOverTempThreshold
OBJECT-TYPE
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
1.3.6.1.4.1.4779.1.3.5.2.1.17INTEGERread-writemandatory
sBTAModulesRPCUnitVA
OBJECT-TYPE
Total Volt-Amps for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.18INTEGERread-onlymandatory
sBTAModulesRPCNumberOfBreakers
OBJECT-TYPE
Number of breakers for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.19INTEGERread-onlymandatory
sBTAModulesRPCLowCurrentThreshold
OBJECT-TYPE
Low current threshold for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.20INTEGERread-writemandatory
sBTAModulesRPCVoltageSource
OBJECT-TYPE
Voltage source for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.21INTEGERread-writemandatory
sBTAModulesRPCSourceSwitchCount
OBJECT-TYPE
Count of Voltage Source Switches for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.22INTEGERread-onlymandatory
sBTAModulesRPCNumberOfSensors
OBJECT-TYPE
Number of environmental sensors for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.23INTEGERread-onlymandatory
sBTAModulesRPCType
OBJECT-TYPE
The type of RPC installed at the indexed location.
1.3.6.1.4.1.4779.1.3.5.2.1.24DisplayStringread-onlymandatory
sBTAModulesRPCOutletTable
OBJECT-TYPE
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
1.3.6.1.4.1.4779.1.3.5.3not-accessiblemandatory
sBTAModulesRPCOutletEntry
OBJECT-TYPE
The outlets to control and get status on.
1.3.6.1.4.1.4779.1.3.5.3.1not-accessiblemandatory
sBTAModulesRPCOutletModuleIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.3.1.1INTEGERread-onlymandatory
sBTAModulesRPCOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.3.1.2INTEGERread-onlymandatory
sBTAModulesRPCOutletState
OBJECT-TYPE
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
1.3.6.1.4.1.4779.1.3.5.3.1.3INTEGER {off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)}read-writemandatory
sBTAModulesRPCOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 16 characters.
1.3.6.1.4.1.4779.1.3.5.3.1.4DisplayStringread-writemandatory
sBTAModulesRPCGroupCmd
OBJECT-TYPE
A character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.outlet. For example 2 2.1,2.12,3.1 will reboot module 2 outlet 2&12 module 3 outlet 1.
1.3.6.1.4.1.4779.1.3.5.4DisplayStringread-writemandatory
sBTAModulesRPCModPortTable
OBJECT-TYPE
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
1.3.6.1.4.1.4779.1.3.5.5not-accessiblemandatory
sBTAModulesRPCModPortEntry
OBJECT-TYPE
The RPCs to control and get status on.
1.3.6.1.4.1.4779.1.3.5.5.1not-accessiblemandatory
sRPCModuleIndex
OBJECT-TYPE
The module number index into the RPC table.
1.3.6.1.4.1.4779.1.3.5.5.1.1INTEGERread-onlymandatory
sRPCPortIndex
OBJECT-TYPE
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
1.3.6.1.4.1.4779.1.3.5.5.1.2INTEGERread-onlymandatory
sRPCType
OBJECT-TYPE
Type of RPC at the module, port index.
1.3.6.1.4.1.4779.1.3.5.5.1.3DisplayStringread-onlymandatory
sRPCName
OBJECT-TYPE
The name (unit id) of the rpc module.
1.3.6.1.4.1.4779.1.3.5.5.1.4DisplayStringread-writemandatory
sRPCFirmwareVersion
OBJECT-TYPE
The firware version of the rpc module.
1.3.6.1.4.1.4779.1.3.5.5.1.5DisplayStringread-onlymandatory
sRPCCurrent
OBJECT-TYPE
The current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.6INTEGERread-onlymandatory
sRPCMaxCurrent
OBJECT-TYPE
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
1.3.6.1.4.1.4779.1.3.5.5.1.7INTEGERread-writemandatory
sRPCVoltage
OBJECT-TYPE
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.8INTEGERread-onlymandatory
sRPCPower
OBJECT-TYPE
The power reading for the power strip. If power measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.9INTEGERread-onlymandatory
sRPCTemperature
OBJECT-TYPE
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.10INTEGERread-onlymandatory
sRPCRebootTimeout
OBJECT-TYPE
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
1.3.6.1.4.1.4779.1.3.5.5.1.11INTEGERread-writemandatory
sRPCAllOutletsCmd
OBJECT-TYPE
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will return unknown (6).
1.3.6.1.4.1.4779.1.3.5.5.1.12INTEGER {off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)}read-writemandatory
sRPCAllOutletsStatus
OBJECT-TYPE
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
1.3.6.1.4.1.4779.1.3.5.5.1.13DisplayStringread-onlymandatory
sRPCCurrentAlarmThreshold
OBJECT-TYPE
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.14INTEGERread-writemandatory
sRPCOverVoltageThreshold
OBJECT-TYPE
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.15INTEGERread-writemandatory
sRPCUnderVoltageThreshold
OBJECT-TYPE
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.16INTEGERread-writemandatory
sRPCNumberOfOutlets
OBJECT-TYPE
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.5.1.17INTEGERread-onlymandatory
sRPCCircuitBreaker
OBJECT-TYPE
Status of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.5.1.18INTEGER {off(0), on(1)}read-onlymandatory
sRPCOverTempThreshold
OBJECT-TYPE
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
1.3.6.1.4.1.4779.1.3.5.5.1.19INTEGERread-writemandatory
sRPCUnitVA
OBJECT-TYPE
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.5.1.20INTEGERread-onlymandatory
sRPCNumberOfBreakers
OBJECT-TYPE
Number of breakers for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.21INTEGERread-onlymandatory
sRPCLowCurrentThreshold
OBJECT-TYPE
Low current threshold for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.22INTEGERread-writemandatory
sRPCVoltageSource
OBJECT-TYPE
Voltage source for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.23INTEGERread-writemandatory
sRPCSourceSwitchCount
OBJECT-TYPE
Voltage source switch count for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.24INTEGERread-writemandatory
sRPCNumberOfSensors
OBJECT-TYPE
Number of sensors for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.25INTEGERread-onlymandatory
sBTAModulesRPCModPortOutletTable
OBJECT-TYPE
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
1.3.6.1.4.1.4779.1.3.5.6not-accessiblemandatory
sBTAModulesRPCModPortOutletEntry
OBJECT-TYPE
The outlets to control and get status on.
1.3.6.1.4.1.4779.1.3.5.6.1not-accessiblemandatory
sRPCOutletModuleIndex
OBJECT-TYPE
The module index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.6.1.1INTEGERread-onlymandatory
sRPCOutletPortIndex
OBJECT-TYPE
The port index to the outlet entry. In the case of ds30s this number is always 1.
1.3.6.1.4.1.4779.1.3.5.6.1.2INTEGERread-onlymandatory
sRPCOutletIndex
OBJECT-TYPE
The outlet index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.6.1.3INTEGERread-onlymandatory
sRPCOutletState
OBJECT-TYPE
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
1.3.6.1.4.1.4779.1.3.5.6.1.4INTEGER {off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)}read-writemandatory
sRPCOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 16 characters.
1.3.6.1.4.1.4779.1.3.5.6.1.5DisplayStringread-writemandatory
sBTAModulesRPCModPortGroupCmd
OBJECT-TYPE
A character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.port.outlet. For example 2 2.1.1,2.1.12,3.4.1 will reboot module 2 port 1 outlet 2&12 module 3 port 4 outlet 1.
1.3.6.1.4.1.4779.1.3.5.7DisplayStringread-writemandatory
sBTAModulesRPCCurrentGroupsCurrentTable
OBJECT-TYPE
A list of total current for RPCs in each current group
1.3.6.1.4.1.4779.1.3.5.8not-accessiblemandatory
sBTAModulesRPCCurrentGroupsCurrentEntry
OBJECT-TYPE
Table of total current measurement by group
1.3.6.1.4.1.4779.1.3.5.8.1not-accessiblemandatory
groupCurrentIndex
OBJECT-TYPE
The index to a group total current.
1.3.6.1.4.1.4779.1.3.5.8.1.1INTEGERread-onlymandatory
groupCurrent
OBJECT-TYPE
Current total for all RPCs in group.
1.3.6.1.4.1.4779.1.3.5.8.1.2INTEGERread-onlymandatory
rpcGroup
OBJECT-TYPE
A character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to warning and emergency thresholds, generating appropriate traps as required by transit of a threshold. A maximum of 8 RPCs may be monitored within a group. The RPC must be connected and operating and the corresponding DS74 serial port must be configured for an RPC-SNMP device type to be allowed group membership.
1.3.6.1.4.1.4779.1.3.5.8.1.3DisplayStringread-writemandatory
warningThreshold
OBJECT-TYPE
The current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent whent the total group current falls below the threshold.
1.3.6.1.4.1.4779.1.3.5.8.1.4INTEGERread-writemandatory
emergencyThreshold
OBJECT-TYPE
The current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sent whent the total group current falls below the threshold.
1.3.6.1.4.1.4779.1.3.5.8.1.5INTEGERread-writemandatory
sBTAModulesRPCBreakersTable
OBJECT-TYPE
Allows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.3.5.9not-accessiblemandatory
sBTAModulesRPCBreakersEntry
OBJECT-TYPE
Status organization by breaker.
1.3.6.1.4.1.4779.1.3.5.9.1not-accessiblemandatory
sBTAModulesRPCBreakersModulesIndex
OBJECT-TYPE
The index into the RPC table.
1.3.6.1.4.1.4779.1.3.5.9.1.1INTEGERread-onlymandatory
sBTAModulesRPCBreakersBreakersIndex
OBJECT-TYPE
The index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.9.1.2INTEGERread-onlymandatory
sBTAModulesRPCBreakersCircuitBreaker
OBJECT-TYPE
Status of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.9.1.3INTEGER {off(0), on(1)}read-onlymandatory
sBTAModulesRPCBreakersCurrent
OBJECT-TYPE
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.4INTEGERread-onlymandatory
sBTAModulesRPCBreakersMaxCurrent
OBJECT-TYPE
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.5INTEGERread-onlymandatory
sBTAModulesRPCBreakersVoltage
OBJECT-TYPE
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.6INTEGERread-onlymandatory
sBTAModulesRPCBreakersPower
OBJECT-TYPE
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.7INTEGERread-onlymandatory
sBTAModulesRPCBreakersVA
OBJECT-TYPE
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.8INTEGERread-onlymandatory
sBTAModulesRPCBreakersCurrentAlarmThreshold
OBJECT-TYPE
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.9.1.9INTEGERread-writemandatory
sRPCModPortBreakersTable
OBJECT-TYPE
Allows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.3.5.10not-accessiblemandatory
sRPCModPortBreakersEntry
OBJECT-TYPE
Status organization by breaker.
1.3.6.1.4.1.4779.1.3.5.10.1not-accessiblemandatory
sRPCBreakersModIndex
OBJECT-TYPE
The module index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.1INTEGERread-onlymandatory
sRPCBreakersPortIndex
OBJECT-TYPE
The port index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.2INTEGERread-onlymandatory
sRPCBreakersBreakersIndex
OBJECT-TYPE
The breaker index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.3INTEGERread-onlymandatory
sRPCBreakersCircuitBreaker
OBJECT-TYPE
Status of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.10.1.4INTEGER {off(0), on(1)}read-onlymandatory
sRPCBreakersCurrent
OBJECT-TYPE
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.5INTEGERread-onlymandatory
sRPCBreakersMaxCurrent
OBJECT-TYPE
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.6INTEGERread-onlymandatory
sRPCBreakersVoltage
OBJECT-TYPE
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.7INTEGERread-onlymandatory
sRPCBreakersPower
OBJECT-TYPE
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.8INTEGERread-onlymandatory
sRPCBreakersVA
OBJECT-TYPE
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.9INTEGERread-onlymandatory
sRPCBreakersCurrentAlarmThreshold
OBJECT-TYPE
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.10.1.10INTEGERread-writemandatory
sBTAModulesSerial
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.3.6
sBTAModulesModem
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.3.7
sBTAControl
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.4
sBTAControlResetUnit
OBJECT-TYPE
Setting this value to 1 will cause the unit to reset. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.4.1INTEGER {noreset(0), reset(1)}read-writemandatory
sBTAControlResetModules
OBJECT-TYPE
Setting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.4.2INTEGER {noreset(0), reset(1)}read-writemandatory
sBTAControlNumOfLoggedUsers
OBJECT-TYPE
Number of users logged in via telnet or SSH.
1.3.6.1.4.1.4779.1.4.3INTEGERread-onlymandatory
sBTAControlUserTable
OBJECT-TYPE
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
1.3.6.1.4.1.4779.1.4.4not-accessiblemandatory
sBTAControlUserEntry
OBJECT-TYPE
The users to get status on.
1.3.6.1.4.1.4779.1.4.4.1not-accessiblemandatory
sBTAControlUserIndex
OBJECT-TYPE
The index to the user entry.
1.3.6.1.4.1.4779.1.4.4.1.1INTEGERread-onlymandatory
sBTAControlUserName
OBJECT-TYPE
The username of the user.
1.3.6.1.4.1.4779.1.4.4.1.2DisplayStringread-onlymandatory
sBTAControlUserAddress
OBJECT-TYPE
The IP address of the user.
1.3.6.1.4.1.4779.1.4.4.1.3IpAddressread-onlymandatory
sBTAControlUserConnection
OBJECT-TYPE
Type of connection. If unknown, user is logging out or the connection is invalid.
1.3.6.1.4.1.4779.1.4.4.1.4INTEGER {serialport(0), telnet(1), ssh(2), unknown(4)}read-onlymandatory
sBTAControlUserConnModule
OBJECT-TYPE
If the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module.
1.3.6.1.4.1.4779.1.4.4.1.5INTEGERread-onlymandatory
sBTAControlUserConnPort
OBJECT-TYPE
The port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not connected to a module.
1.3.6.1.4.1.4779.1.4.4.1.6INTEGERread-onlymandatory
sBTAControlUserTerminateUser
OBJECT-TYPE
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.4.4.1.7INTEGER {terminate(1)}read-writemandatory
sBTAFileTransfer
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.5
sBTAFileTransferEnableUpgradeFTPFileTransfer
OBJECT-TYPE
Setting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be established for the purpose of transmitting a firmware upgrade file.
1.3.6.1.4.1.4779.1.5.1INTEGER {enableUpgradeFileTransferDownloadViaFTP(1)}read-writemandatory
sBTAEnvironmental
OBJECT-IDENTITY
1.3.6.1.4.1.4779.1.6
sBTAModulesEnvironmentalObjectsTable
OBJECT-TYPE
Allows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.6.1not-accessiblemandatory
sBTAModulesEnvironmentalObjectsEntry
OBJECT-TYPE
Status organization by sensor.
1.3.6.1.4.1.4779.1.6.1.1not-accessiblemandatory
sBTAModulesEnvironmentalModulesIndex
OBJECT-TYPE
Module Index for Environemntal table
1.3.6.1.4.1.4779.1.6.1.1.1INTEGERread-onlymandatory
sBTAModulesEnvironmentalSensorsIndex
OBJECT-TYPE
Sensor Index for Environemntal table
1.3.6.1.4.1.4779.1.6.1.1.2INTEGERread-onlymandatory
sBTAModulesEnvironmentalType
OBJECT-TYPE
Environmental Object Type.
1.3.6.1.4.1.4779.1.6.1.1.3INTEGERread-onlymandatory
sBTAModulesEnvironmentalName
OBJECT-TYPE
The name for the environmental object.
1.3.6.1.4.1.4779.1.6.1.1.4DisplayStringread-writemandatory
sBTAModulesEnvironmentalMeasurement
OBJECT-TYPE
The measurement or state for the object.
1.3.6.1.4.1.4779.1.6.1.1.5INTEGERread-onlymandatory
sBTAModulesEnvironmentalHiThreshold
OBJECT-TYPE
Hi threshold for object.
1.3.6.1.4.1.4779.1.6.1.1.6INTEGERread-writemandatory
sBTAModulesEnvironmentalLoThreshold
OBJECT-TYPE
Lo threshold for object.
1.3.6.1.4.1.4779.1.6.1.1.7INTEGERread-writemandatory
sBTAModulesEnvironmentalMax
OBJECT-TYPE
Max value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.1.1.8INTEGERread-writemandatory
sBTAModulesEnvironmentalMin
OBJECT-TYPE
Min value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.1.1.9INTEGERread-writemandatory
sBTAModulesEnvironmentalHiThresholdEn
OBJECT-TYPE
Hi threshold enable for object.
1.3.6.1.4.1.4779.1.6.1.1.10INTEGERread-writemandatory
sBTAModulesEnvironmentalLoThresholdEn
OBJECT-TYPE
Lo threshold enable for object.
1.3.6.1.4.1.4779.1.6.1.1.11INTEGERread-writemandatory
sBTAModulesEnvironmentalStateTrapEn
OBJECT-TYPE
Trap enable for environmental sensors with contacts.
1.3.6.1.4.1.4779.1.6.1.1.12INTEGERread-writemandatory
sRPCEnvironmentalObjectsTable
OBJECT-TYPE
Allows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.6.2not-accessiblemandatory
sRPCEnvironmentalObjectsEntry
OBJECT-TYPE
Status organization by sensor.
1.3.6.1.4.1.4779.1.6.2.1not-accessiblemandatory
sRPCEnvironmentalModuleIndex
OBJECT-TYPE
Module Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.1INTEGERread-onlymandatory
sRPCEnvironmentalPortIndex
OBJECT-TYPE
Port Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.2INTEGERread-onlymandatory
sRPCEnvironmentalSensorsIndex
OBJECT-TYPE
Sensor Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.3INTEGERread-onlymandatory
sRPCEnvironmentalType
OBJECT-TYPE
Environmental Object Type.
1.3.6.1.4.1.4779.1.6.2.1.4INTEGERread-onlymandatory
sRPCEnvironmentalName
OBJECT-TYPE
The name for the environmental object.
1.3.6.1.4.1.4779.1.6.2.1.5DisplayStringread-writemandatory
sRPCEnvironmentalMeasurement
OBJECT-TYPE
The measurement or state for the object.
1.3.6.1.4.1.4779.1.6.2.1.6INTEGERread-onlymandatory
sRPCEnvironmentalHiThreshold
OBJECT-TYPE
Hi threshold for object.
1.3.6.1.4.1.4779.1.6.2.1.7INTEGERread-writemandatory
sRPCEnvironmentalLoThreshold
OBJECT-TYPE
Lo threshold for object.
1.3.6.1.4.1.4779.1.6.2.1.8INTEGERread-writemandatory
sRPCEnvironmentalMax
OBJECT-TYPE
Max value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.2.1.9INTEGERread-writemandatory
sRPCEnvironmentalMin
OBJECT-TYPE
Min value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.2.1.10INTEGERread-writemandatory
sRPCEnvironmentalHiThresholdEn
OBJECT-TYPE
Hi threshold enable for object.
1.3.6.1.4.1.4779.1.6.2.1.11INTEGERread-writemandatory
sRPCEnvironmentalLoThresholdEn
OBJECT-TYPE
Lo threshold enable for object.
1.3.6.1.4.1.4779.1.6.2.1.12INTEGERread-writemandatory
sRPCEnvironmentalStateTrapEn
OBJECT-TYPE
Trap enable for environmental sensors with contacts.
1.3.6.1.4.1.4779.1.6.2.1.13INTEGERread-writemandatory
sBTAEnvironmentalAllTemperatureSensorsHiThreshold
OBJECT-TYPE
Hi Threshold for all temperature sensors.
1.3.6.1.4.1.4779.1.6.3INTEGERread-writemandatory
sBTAEnvironmentalAllTemperatureSensorsLoThreshold
OBJECT-TYPE
Lo Threshold for all temperature sensors.
1.3.6.1.4.1.4779.1.6.4INTEGERread-writemandatory
sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnable
OBJECT-TYPE
Hi Threshold trap enable for all temperature sensors.
1.3.6.1.4.1.4779.1.6.5INTEGERread-writemandatory
sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnable
OBJECT-TYPE
Lo Threshold trap enable for all temperature sensors.
1.3.6.1.4.1.4779.1.6.6INTEGERread-writemandatory
sBTAEnvironmentalAllSensorsStateTrapEnable
OBJECT-TYPE
State change environmental sensor (ex: contact) trap enable.
1.3.6.1.4.1.4779.1.6.7INTEGERread-writemandatory
mtrapargs
OBJECT-IDENTITY
1.3.6.1.4.1.4779.3
mtrapargsInteger
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.1INTEGERread-onlymandatory
mtrapargsIpAddress
OBJECT-TYPE
This OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0.
1.3.6.1.4.1.4779.3.2IpAddressread-onlymandatory
mtrapargsString
OBJECT-TYPE
This OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.4779.3.3DisplayStringread-onlymandatory
mtrapargsGauge
OBJECT-TYPE
This OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.4Gaugeread-onlymandatory
mtrapargsTimeTicks
OBJECT-TYPE
This OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.5TimeTicksread-onlymandatory
sBTAModuleIndex
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value will equal the slot of the module. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.6INTEGERread-onlymandatory
sBTAOutletIndex
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.7INTEGERread-onlymandatory
sBTAPortIndex
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.8INTEGERread-onlymandatory
sBTAVoltageSource
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage source in an RPC. Value is 1 or 2, depending on which voltage source is powering the RPC. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.9INTEGERread-writemandatory
sBTASourceSwitchCount
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of voltage source transitions in an RPC. Value is 0 to 255, an 8-bit w/rollover count of number of times voltage source has been switched from one source to another. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.10INTEGERread-onlymandatory
sBTASensorIndex
OBJECT-TYPE
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS module. Value is 1 to number of sensors controlled by the ds module. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.11INTEGERread-onlymandatory
sBTABreakerIndex
OBJECT-TYPE
This is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total number of breakers inside the particular RPC. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.12INTEGERread-onlymandatory

Notifications

NameOIDStatus
communicationLost
NOTIFICATION-TYPE
SEVERE: Communication to the unit has been lost. Steps to reestablish communication are in progress. Argument is timeTicks when communication was lost.
1.3.6.1.4.1.4779.0.1
communicationEstablished
NOTIFICATION-TYPE
INFORMATION: Communication with the unit has been established. Argument is timeTicks when communication was established.
1.3.6.1.4.1.4779.0.2
outletOn
NOTIFICATION-TYPE
WARNING: The specified RPC outlet has turned on. If sBTAOutletIndex equals zero, then all outlets have turned on.
1.3.6.1.4.1.4779.0.3
outletOff
NOTIFICATION-TYPE
WARNING: The specified RPC outlet has turned off. If sBTAOutletIndex equals zero, then all outlets have turned off.
1.3.6.1.4.1.4779.0.4
outletReboot
NOTIFICATION-TYPE
WARNING: The specified RPC outlet has rebooted. If sBTAOutletIndex equals zero, then all outlets have rebooted.
1.3.6.1.4.1.4779.0.5
outletLocked
NOTIFICATION-TYPE
WARNING: The specified RPC outlet has been locked. If sBTAOutletIndex equals zero, then all outlets have been locked.
1.3.6.1.4.1.4779.0.6
outletUnlocked
NOTIFICATION-TYPE
WARNING: The specified RPC outlet has been unlocked. If sBTAOutletIndex equals zero, then all outlets have been unlocked.
1.3.6.1.4.1.4779.0.7
configChangeSNMP
NOTIFICATION-TYPE
WARNING: The SNMP configuration has been changed.
1.3.6.1.4.1.4779.0.8
configChangeOutlet
NOTIFICATION-TYPE
WARNING: The specified outlet has changed configuration.
1.3.6.1.4.1.4779.0.9
accessViolationConsole
NOTIFICATION-TYPE
WARNING: Someone has attempted to login via the console with the incorrect password.
1.3.6.1.4.1.4779.0.10
accessViolationNetwork
NOTIFICATION-TYPE
WARNING: Someone has attempted to login via the network with the incorrect password.
1.3.6.1.4.1.4779.0.11
userPasswordChange
NOTIFICATION-TYPE
WARNING: The password for the specified user has been changed.
1.3.6.1.4.1.4779.0.12
userAdded
NOTIFICATION-TYPE
WARNING: The specified user has been added.
1.3.6.1.4.1.4779.0.13
userLoggedIn
NOTIFICATION-TYPE
INFORMATIONAL: The specified user has logged in.
1.3.6.1.4.1.4779.0.14
temperatureThresholdViolation
NOTIFICATION-TYPE
WARNING: A temperature threshold has been violated. The argument is the rpc index.
1.3.6.1.4.1.4779.0.15
temperatureThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: A temperature threshold violated has been cleared. The argument is the rpc index.
1.3.6.1.4.1.4779.0.16
currentThresholdViolation
NOTIFICATION-TYPE
WARNING: The preset current threshold has been violated. The argument is the rpc index.
1.3.6.1.4.1.4779.0.17
currentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: A current threshold violation has been cleared. The argument is the rpc index.
1.3.6.1.4.1.4779.0.18
resetModulesEvent
NOTIFICATION-TYPE
WARNING: A reset modules (RM) command has been executed.
1.3.6.1.4.1.4779.0.19
resetModulesComplete
NOTIFICATION-TYPE
WARNING: A reset modules (RM) command has been completed.
1.3.6.1.4.1.4779.0.20
errorExecutingSNMPCommand
NOTIFICATION-TYPE
WARNING: unable to execute SNMP command. String contains reason and command.
1.3.6.1.4.1.4779.0.21
fileTransferComplete
NOTIFICATION-TYPE
INFORMATIONAL: file transfer to unit complete.
1.3.6.1.4.1.4779.0.22
userTerminated
NOTIFICATION-TYPE
WARNING: user terminated. Argument specifies user.
1.3.6.1.4.1.4779.0.23
voltageOverThresholdViolation
NOTIFICATION-TYPE
WARNING: Over voltage. Argument specifies rpc.
1.3.6.1.4.1.4779.0.24
voltageOverThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Over voltage cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.0.25
voltageUnderThresholdViolation
NOTIFICATION-TYPE
WARNING: Under voltage. Argument specifies rpc.
1.3.6.1.4.1.4779.0.26
voltageUnderThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Under voltage cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.0.27
circuitBreakerAlarm
NOTIFICATION-TYPE
WARNING: Circuit breaker is blown. Argument specifies rpc.
1.3.6.1.4.1.4779.0.28
rpcFailureAlarm
NOTIFICATION-TYPE
WARNING: Unable to communicate to an RPC. Argument specifies port number of RPC.
1.3.6.1.4.1.4779.0.29
userDeleted
NOTIFICATION-TYPE
INFORMATIONAL: The specified user has logged in.
1.3.6.1.4.1.4779.0.30
warningThresholdViolation
NOTIFICATION-TYPE
1.3.6.1.4.1.4779.0.31
warningThresholdViolationClear
NOTIFICATION-TYPE
1.3.6.1.4.1.4779.0.32
emergencyThresholdViolation
NOTIFICATION-TYPE
1.3.6.1.4.1.4779.0.33
emergencyThresholdViolationClear
NOTIFICATION-TYPE
1.3.6.1.4.1.4779.0.34
circuitBreakerAlarmClearTrap
NOTIFICATION-TYPE
Circuit breaker has been reset. Argument specifies rpc.
1.3.6.1.4.1.4779.0.35
currentUnderThresholdViolation
NOTIFICATION-TYPE
WARNING: Low current. Argument specifies rpc.
1.3.6.1.4.1.4779.0.36
currentUnderThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low current cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.0.37
voltageSourceChangeAlarm
NOTIFICATION-TYPE
WARNING: RPC voltage source has changed. Arguments specify modules index, current voltage source, and count of number of times source has been switched.
1.3.6.1.4.1.4779.0.38
sensorTempThreshHiAlarmTrap
NOTIFICATION-TYPE
WARNING: Hi threshold exceeded. Arguments specify module, sensor number
1.3.6.1.4.1.4779.0.39
sensorTempThreshHiAlarmClearedTrap
NOTIFICATION-TYPE
WARNING: Hi threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.0.40
sensorTempThreshLoAlarmTrap
NOTIFICATION-TYPE
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.0.41
sensorTempThreshLoAlarmClearedTrap
NOTIFICATION-TYPE
WARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.0.42
sensorStateChangeTrap
NOTIFICATION-TYPE
WARNING: Sensor state (contact, detector, etc) has changed. Arguments specify module, sensor number
1.3.6.1.4.1.4779.0.43
configChangeSensor
NOTIFICATION-TYPE
WARNING: The specified environmental sensor has changed configuration.
1.3.6.1.4.1.4779.0.44
sensorTypeChange
NOTIFICATION-TYPE
WARNING: The specified environmental sensor is now a different type.
1.3.6.1.4.1.4779.0.45