Description

This MIB module supports monitoring of port optics for parameters like, temperature, Tx Power, Rx Power, Tx Bias Current, etc.,.

Contact

Postal: Extreme Networks, Inc. 6480 Via Del Oro San Jose, CA 95119 USA Phone: +1 408 579-2800 E-mail: support@extremenetworks.com WWW: http://www.extremenetworks.com

Imports

FromSymbols
Brocade-REG-MIBbcsiModules
IF-MIBifIndex
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BROCADE-OPTICAL-MONITORING-MIB
Brocade-REG-MIB
IANAifType-MIB
IF-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
bcsiOptMonNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.1588.3.1.8.0
bcsiOptMonObjects
OBJECT-IDENTITY
1.3.6.1.4.1.1588.3.1.8.1
bcsiOptMonLaneTable
OBJECT-TYPE
This table lists the instrumented parameters of all lanes within a 40G Optic of type SR4 and LR4, 100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes per optic, LR10 has 10 lanes per optic.
1.3.6.1.4.1.1588.3.1.8.1.1not-accessiblecurrent
bcsiOptMonLaneEntry
OBJECT-TYPE
Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.
1.3.6.1.4.1.1588.3.1.8.1.1.1not-accessiblecurrent
bcsiOptMonLaneNum
OBJECT-TYPE
The lane number of this 40G or 100G optic. LR4 and SR4 have 4 lanes per optic. LR10 has 10 lanes per optic.
1.3.6.1.4.1.1588.3.1.8.1.1.1.1Unsigned32not-accessiblecurrent
bcsiOptMonLaneTemperature
OBJECT-TYPE
This object holds the value of the transmitter laser diode temperature for the lane in the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning.
1.3.6.1.4.1.1588.3.1.8.1.1.1.2SnmpAdminString (SIZE(0..32))read-onlycurrent
bcsiOptMonLaneTxPowerStatus
OBJECT-TYPE
This object holds the status of the transmitter optical signal power for the lane in the interface, indicating whether this is normal or an alarm is present.
1.3.6.1.4.1.1588.3.1.8.1.1.1.3INTEGER {notSupported(1), notApplicable(2), highAlarm(3), highWarn(4), normal(5), lowWarn(6), lowAlarm(7)}read-onlycurrent
bcsiOptMonLaneTxPower
OBJECT-TYPE
This object holds the value of the transmitter optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
1.3.6.1.4.1.1588.3.1.8.1.1.1.4SnmpAdminString (SIZE(0..32))read-onlycurrent
bcsiOptMonLaneTxPowerVal
OBJECT-TYPE
This object holds the value of the transmitter optical signal power for the lane in the interface, measured in microWatt.
1.3.6.1.4.1.1588.3.1.8.1.1.1.5Unsigned32read-onlycurrent
bcsiOptMonLaneRxPowerStatus
OBJECT-TYPE
This object holds the status of the receiver optical signal power for the lane in the interface, indicating whether this is normal or an alarm is present.
1.3.6.1.4.1.1588.3.1.8.1.1.1.6INTEGER {notSupported(1), notApplicable(2), highAlarm(3), highWarn(4), normal(5), lowWarn(6), lowAlarm(7)}read-onlycurrent
bcsiOptMonLaneRxPower
OBJECT-TYPE
This object holds the value of the receiver optical signal power for the lane in the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm.
1.3.6.1.4.1.1588.3.1.8.1.1.1.7SnmpAdminString (SIZE(0..32))read-onlycurrent
bcsiOptMonLaneRxPowerVal
OBJECT-TYPE
This object holds the value of the receiver optical signal power for the lane in the interface, measured in microWatt.
1.3.6.1.4.1.1588.3.1.8.1.1.1.8Unsigned32read-onlycurrent
bcsiOptMonLaneTxBiasCurrent
OBJECT-TYPE
Tx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm.
1.3.6.1.4.1.1588.3.1.8.1.1.1.9SnmpAdminString (SIZE(0..32))read-onlycurrent
bcsiOptMonInfoTable
OBJECT-TYPE
This table lists the instrumented parameters of all optical interfaces.
1.3.6.1.4.1.1588.3.1.8.1.2not-accessiblecurrent
bcsiOptMonInfoEntry
OBJECT-TYPE
Only the ifIndices of optical interfaces whose parameters need to be monitored will be used to index this table.
1.3.6.1.4.1.1588.3.1.8.1.2.1not-accessiblecurrent
bcsiOptMonTemperature
OBJECT-TYPE
This object holds the value of the transmitter laser diode temperature for the interface. This object indicates the health of the transmitter. The format is xxx.yyyy C(elcius), followed by whether the measured value is normal, high/low alarm or high/low warning. For 100G and 40G optic, this returns the average temperature for all lanes.
1.3.6.1.4.1.1588.3.1.8.1.2.1.1DisplayString (SIZE(0..32))read-onlycurrent
bcsiOptMonTxPowerStatus
OBJECT-TYPE
This object holds the status of the transmit optical signal power for the interface, indicating whether this is normal or an alarm is present.
1.3.6.1.4.1.1588.3.1.8.1.2.1.2INTEGER {notSupported(1), notApplicable(2), highAlarm(3), highWarn(4), normal(5), lowWarn(6), lowAlarm(7)}read-onlycurrent
bcsiOptMonTxPower
OBJECT-TYPE
This object holds the value of the transmitter optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G optic, this returns the aggregated Tx Power for all lanes.
1.3.6.1.4.1.1588.3.1.8.1.2.1.3DisplayString (SIZE(0..32))read-onlycurrent
bcsiOptMonTxPowerVal
OBJECT-TYPE
This object holds the value of the transmitter optical signal power for the interface, measured in microWatt. For 100G optic, this returns the aggregated Tx Power for all lanes
1.3.6.1.4.1.1588.3.1.8.1.2.1.4Unsigned32read-onlycurrent
bcsiOptMonRxPowerStatus
OBJECT-TYPE
This object holds the status of the receiver optical signal power for the interface, indicating whether this is normal or an alarm is present.
1.3.6.1.4.1.1588.3.1.8.1.2.1.5INTEGER {notSupported(1), notApplicable(2), highAlarm(3), highWarn(4), normal(5), lowWarn(6), lowAlarm(7)}read-onlycurrent
bcsiOptMonRxPower
OBJECT-TYPE
This object holds the value of the receiver optical signal power for the interface, measured in dBm, followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Rx Power for all lanes.
1.3.6.1.4.1.1588.3.1.8.1.2.1.6DisplayString (SIZE(0..32))read-onlycurrent
bcsiOptMonRxPowerVal
OBJECT-TYPE
This object holds the value of the receiver optical signal power for the interface, measured in microWatt. For 100G and 40G optic, this returns the aggregated Rx Power for all lanes
1.3.6.1.4.1.1588.3.1.8.1.2.1.7Unsigned32read-onlycurrent
bcsiOptMonTxBiasCurrent
OBJECT-TYPE
Tx Bias Current. It is measured in mA, and is followed by whether this is a normal value, or high/low warning or alarm. For 100G and 40G optic, this returns the aggregated Tx Bias Current for all lanes.
1.3.6.1.4.1.1588.3.1.8.1.2.1.8DisplayString (SIZE(0..32))read-onlycurrent
bcsiIfMediaInfoTable
OBJECT-TYPE
This table lists the information of the media device (SFP/XFP/Copper) installed in the physical port. Only the ifIndices of Ethernet ports those are associated with the operational cards will be included in this table.
1.3.6.1.4.1.1588.3.1.8.1.3not-accessiblecurrent
bcsiIfMediaInfoEntry
OBJECT-TYPE
An entry in this table. The ifIndices of ethernet interfaces will be used to index this table.
1.3.6.1.4.1.1588.3.1.8.1.3.1not-accessiblecurrent
bcsiIfMediaType
OBJECT-TYPE
he type of the media installed in the physical port.
1.3.6.1.4.1.1588.3.1.8.1.3.1.1DisplayString (SIZE(0..128))read-onlycurrent
bcsiIfMediaVendorName
OBJECT-TYPE
The media vendor name, full name of the corporation.
1.3.6.1.4.1.1588.3.1.8.1.3.1.2DisplayString (SIZE(0..128))read-onlycurrent
bcsiIfMediaVersion
OBJECT-TYPE
The media vendor product version number.
1.3.6.1.4.1.1588.3.1.8.1.3.1.3DisplayString (SIZE(0..128))read-onlycurrent
bcsiIfMediaPartNumber
OBJECT-TYPE
The media vendor part number.
1.3.6.1.4.1.1588.3.1.8.1.3.1.4DisplayString (SIZE(0..128))read-onlycurrent
bcsiIfMediaSerialNumber
OBJECT-TYPE
The vendor serial number of the media device.
1.3.6.1.4.1.1588.3.1.8.1.3.1.5DisplayString (SIZE(0..128))read-onlycurrent
bcsiOptMonConformance
OBJECT-IDENTITY
1.3.6.1.4.1.1588.3.1.8.2
bcsiOptMonCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.1588.3.1.8.2.1
bcsiOptMonGroups
OBJECT-IDENTITY
1.3.6.1.4.1.1588.3.1.8.2.2

Conformance

NameOIDStatus
bcsiOptMonCompliance
MODULE-COMPLIANCE
The compliance statement for entities which implement BROCADE-OPTICAL-MONITORING-MIB.
1.3.6.1.4.1.1588.3.1.8.2.1.1current
bcsiOptMonLaneMonGroup
OBJECT-GROUP
A collection of objects for Optical Lane Monitoring of interface optics.
1.3.6.1.4.1.1588.3.1.8.2.2.1current
bcsiOptMonInfoMonGroup
OBJECT-GROUP
A collection of objects for Optical Monitoring of interface optics.
1.3.6.1.4.1.1588.3.1.8.2.2.2current
bcsiIfMediaGroup
OBJECT-GROUP
A collection of objects for monitoring media information of interfaces.
1.3.6.1.4.1.1588.3.1.8.2.2.3current