MIBs Depot

BPDU-PROTECTION-MIB

Registered at
1.3.6.1.4.1.171.12.76
Last updated
1909-03-12 00:00
Organization
D-Link Corp.
Namespace
dlink
Source file
BPDU-PROTECTION-MIB
Digest
sha256:520516c1abac4676b0ac3e0a7c77b318c460e2d9e9ddf168641cd5d094fc1eb1

Description

The structure of BPDU Protection management for the proprietary enterprise.

Contact

http://support.dlink.com

Imports

FromSymbols
DLINK-ID-REC-MIBdlink-common-mgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BPDU-PROTECTION-MIB
DLINK-ID-REC-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
swBpduProtectionCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.1
swBpduProtectionAdminState
OBJECT-TYPE
This object indicates the BPDU Protection status for the system.
1.3.6.1.4.1.171.12.76.1.1INTEGER {enabled(1), disabled(2)}read-writecurrent
swBpduProtectionRecoveryTime
OBJECT-TYPE
This object indicates the recovery time. The range is from 60 to 1000000 sec. The value of 0 disables the recover function.
1.3.6.1.4.1.171.12.76.1.2INTEGER (0 | 60..1000000)read-writecurrent
swBpduProtectionTrapMode
OBJECT-TYPE
This object indicates the BPDU Protection trap mode for the system.
1.3.6.1.4.1.171.12.76.1.3INTEGER {none(1), attackDetected(2), attackCleared(3), both(4)}read-writecurrent
swBpduProtectionLogMode
OBJECT-TYPE
This object indicates the BPDU Protection log mode for the system.
1.3.6.1.4.1.171.12.76.1.4INTEGER {none(1), attackDetected(2), attackCleared(3), both(4)}read-writecurrent
swBpduProtectionInfo
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.2
swBpduProtectionMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.3
swBpduProtectionPortTable
OBJECT-TYPE
The table specifies the BPDU Protection function specified by port.
1.3.6.1.4.1.171.12.76.3.1not-accessiblecurrent
swBpduProtectionPortEntry
OBJECT-TYPE
The table specifies the BPDU Protection function specified by port.
1.3.6.1.4.1.171.12.76.3.1.1not-accessiblecurrent
swBpduProtectionPortIndex
OBJECT-TYPE
This object indicates the module's port number. The range is from 1 to the maximum port number specified in the module.
1.3.6.1.4.1.171.12.76.3.1.1.1INTEGER (1..65535)read-onlycurrent
swBpduProtectionPortState
OBJECT-TYPE
This object indicates the BPDU Protection function state on the port.
1.3.6.1.4.1.171.12.76.3.1.1.2INTEGER {enabled(1), disabled(2)}read-writecurrent
swBpduProtectionPortMode
OBJECT-TYPE
This object indicates the BPDU Protection function mode on the port.
1.3.6.1.4.1.171.12.76.3.1.1.3INTEGER {drop(1), block(2), shutdown(3)}read-writecurrent
swBpduProtectionPortStatus
OBJECT-TYPE
This object indicates the port status.
1.3.6.1.4.1.171.12.76.3.1.1.4INTEGER {normal(1), underAttack(2)}read-onlycurrent
swBpduProtectionNotify
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.4
swBpduProtectionNotifyPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.4.0
swBpduProtectionNotificationBidings
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.76.4.2
swBpduProtectionRecoveryMethod
OBJECT-TYPE
This object indicates the method of recovery from BPDU under attack.
1.3.6.1.4.1.171.12.76.4.2.1INTEGER {automatically(1), manually(2)}accessible-for-notifycurrent

Notifications

NameOIDStatus
swBpduProtectionUnderAttackingTrap
NOTIFICATION-TYPE
When the BPDU Protection trap is enabled, if the specific port changes from a normal state to an under attack state, a trap will be sent out.
1.3.6.1.4.1.171.12.76.4.0.1current
swBpduProtectionRecoveryTrap
NOTIFICATION-TYPE
When the BPDU Protection trap is enabled, if the specific port changes from an under attack state to a normal state, a trap will be sent out.
1.3.6.1.4.1.171.12.76.4.0.2current