BLADE-MIB
- Registered at
- 1.3.6.1.4.1.2.3
- Namespace
- ibm
- Source file
BLADE-MIB- Digest
sha256:37d40c091374e32b1d3ff51b08844398737d1e6cfc4d111c571bbdda2c32fffd
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BLADE-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2.3.51 | netfinitySupportProcessorAgent |
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| EntryStatus type | ||||
| InetAddressIPv6 TEXTUAL-CONVENTION Represents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6 | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ibm OBJECT-IDENTITY | 1.3.6.1.4.1.2 | |||
| ibmAgents OBJECT-IDENTITY | 1.3.6.1.4.1.2.3 | |||
| netfinitySupportProcessorAgent OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51 | |||
| bladeCenterSnmpMIB OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2 | |||
| monitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2 | |||
| temperature OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1 | |||
| planarTemp OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1.1 | |||
| mmTemp OBJECT-TYPE Management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.1.2 | OCTET STRING | read-only | mandatory |
| ambientTemp OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.1.5 | |||
| frontPanelTemp OBJECT-TYPE The front panel temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.1.5.1 | OCTET STRING | read-only | mandatory |
| frontPanel2Temp OBJECT-TYPE The front panel 2 temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter HT only | 1.3.6.1.4.1.2.3.51.2.2.1.5.2 | OCTET STRING | read-only | mandatory |
| voltage OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.2 | |||
| planarVolt OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.2.1 | |||
| plus5Volt OBJECT-TYPE +5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.1 | OCTET STRING | read-only | mandatory |
| plus3Pt3Volt OBJECT-TYPE +3.3 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.2 | OCTET STRING | read-only | mandatory |
| plus12Volt OBJECT-TYPE +12 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.3 | OCTET STRING | read-only | mandatory |
| minus5Volt OBJECT-TYPE -5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.5 | OCTET STRING | read-only | mandatory |
| plus2Pt5Volt OBJECT-TYPE +2.5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.6 | OCTET STRING | read-only | mandatory |
| plus1Pt8Volt OBJECT-TYPE +1.8 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.2.1.8 | OCTET STRING | read-only | mandatory |
| blowers OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.3 | |||
| blower1speed OBJECT-TYPE Blower 1 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.1 | OCTET STRING | read-only | mandatory |
| blower2speed OBJECT-TYPE Blower 2 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.2 | OCTET STRING | read-only | mandatory |
| blower3speed OBJECT-TYPE Blower 3 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.3 | OCTET STRING | read-only | mandatory |
| blower4speed OBJECT-TYPE Blower 4 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.4 | OCTET STRING | read-only | mandatory |
| blower1State OBJECT-TYPE The health state for blower 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.10 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| blower2State OBJECT-TYPE The health state for blower 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.11 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| blower3State OBJECT-TYPE The health state for blower 3. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.12 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| blower4State OBJECT-TYPE The health state for blower 4. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.13 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| blower1speedRPM OBJECT-TYPE Blower 1 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.20 | OCTET STRING | read-only | mandatory |
| blower2speedRPM OBJECT-TYPE Blower 2 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.21 | OCTET STRING | read-only | mandatory |
| blower3speedRPM OBJECT-TYPE Blower 3 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.22 | OCTET STRING | read-only | mandatory |
| blower4speedRPM OBJECT-TYPE Blower 4 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.23 | OCTET STRING | read-only | mandatory |
| blower1ControllerState OBJECT-TYPE The health state for the controller for blower 1. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.30 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| blower2ControllerState OBJECT-TYPE The health state for the controller for blower 2. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.31 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| blower3ControllerState OBJECT-TYPE The health state for the controller for blower 3. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.32 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| blower4ControllerState OBJECT-TYPE The health state for the controller for blower 4. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.33 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| blower1ExhaustTemp OBJECT-TYPE The exhaust temperature in degrees Celsius for blower 1. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.40 | OCTET STRING | read-only | mandatory |
| blower2ExhaustTemp OBJECT-TYPE The exhaust temperature in degrees Celsius for blower 2. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.41 | OCTET STRING | read-only | mandatory |
| blower3ExhaustTemp OBJECT-TYPE The exhaust temperature in degrees Celsius for blower 3. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.42 | OCTET STRING | read-only | mandatory |
| blower4ExhaustTemp OBJECT-TYPE The exhaust temperature in degrees Celsius for blower 4. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.3.43 | OCTET STRING | read-only | mandatory |
| powerModuleHealth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.4 | |||
| powerModuleHealthTable OBJECT-TYPE Table of power module health information. Contains the power health information for each power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1 | not-accessible | mandatory | |
| powerModuleHealthEntry OBJECT-TYPE Power Module health entry | 1.3.6.1.4.1.2.3.51.2.2.4.1.1 | not-accessible | mandatory | |
| powerModuleIndex OBJECT-TYPE Power module sequence index. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.1 | INTEGER | read-only | mandatory |
| powerModuleExists OBJECT-TYPE Indicates whether the power module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| powerModuleState OBJECT-TYPE The health state for the power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.3 | INTEGER {unknown(0), good(1), warning(2), notAvailable(3), critical(4)} | read-only | mandatory |
| powerModuleDetails OBJECT-TYPE The details for this power module. | 1.3.6.1.4.1.2.3.51.2.2.4.1.1.4 | OCTET STRING | read-only | mandatory |
| spStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5 | |||
| mmBistAndChassisStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5.2 | |||
| bistSdram OBJECT-TYPE MM BIST DRAM test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.1 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistRs485Port1 OBJECT-TYPE MM BIST RS 485 legacy test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.2 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistRs485Port2 OBJECT-TYPE MM BIST RS 485 local bus test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.3 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistNvram OBJECT-TYPE MM BIST NVRAM test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.4 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistRtc OBJECT-TYPE MM BIST Real Time Clock test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.5 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistLocalI2CBus OBJECT-TYPE MM BIST Local I2C bus test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.7 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPrimaryMainAppFlashImage OBJECT-TYPE MM BIST Primary Main Application Firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.8 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistSecondaryMainAppFlashImage OBJECT-TYPE MM BIST Secondary Main Application test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.9 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistBootRomFlashImage OBJECT-TYPE MM BIST Boot Firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.10 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistEthernetPort1 OBJECT-TYPE MM BIST external ethernet port test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.11 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistEthernetPort2 OBJECT-TYPE MM BIST internal ethernet port test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.12 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistInternalPCIBus OBJECT-TYPE MM BIST PCI bus test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.13 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistExternalI2CDevices OBJECT-TYPE MM BIST external I2C devices test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.14 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistUSBController OBJECT-TYPE MM BIST USB controller test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.15 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistVideoCompressorBoard OBJECT-TYPE MM BIST Video Compressor Board test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.16 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistRemoteVideo OBJECT-TYPE MM BIST Remote Video test result. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.5.2.17 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | deprecated |
| bistPrimaryBus OBJECT-TYPE MM BIST primary mid-plane bus test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.18 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistInternalEthernetSwitch OBJECT-TYPE MM BIST internal external switch test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.19 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistVideoCapture OBJECT-TYPE MM BIST video capture test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.20 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistUSBKeyboardMouseEmulation OBJECT-TYPE MM BIST USB keyboard and mouse test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.21 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistUSBMassStorageEmulation OBJECT-TYPE MM BIST mass storage emulation test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.22 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistUSBKeyboardMouseFirmware OBJECT-TYPE MM BIST USB keyboard and mouse firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.23 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistUSBMassStorageFirmware OBJECT-TYPE MM BIST USB keyboard mouse firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.24 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPrimaryCore OBJECT-TYPE MM BIST primary core test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.25 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistSecondaryCore OBJECT-TYPE MM BIST secondary core test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.26 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistInternalIOExpander OBJECT-TYPE MM BIST internal IO expander test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.27 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistRemoteControlFirmware OBJECT-TYPE MM BIST Remote Control firmware test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.28 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistPhysicalNetworkLink OBJECT-TYPE MM BIST Physical Network Link test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.29 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistLogicalNetworkLink OBJECT-TYPE MM BIST Logical Network Link test result. | 1.3.6.1.4.1.2.3.51.2.2.5.2.30 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| bistBladesInstalled OBJECT-TYPE The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.33 | OCTET STRING | read-only | mandatory |
| bistBladesCommunicating OBJECT-TYPE The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.49 | OCTET STRING | read-only | mandatory |
| bistBlowersInstalled OBJECT-TYPE The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.5.2.65 | OCTET STRING | read-only | mandatory |
| bistBlowersFunctional OBJECT-TYPE The blowers installed on the chassis that are functional. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.5.2.73 | OCTET STRING | read-only | mandatory |
| bistMediaTrayInstalled OBJECT-TYPE Indicates whether a media tray is installed on the chassis. | 1.3.6.1.4.1.2.3.51.2.2.5.2.74 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistMediaTrayCommunicating OBJECT-TYPE Indicates whether a media tray is communicating. | 1.3.6.1.4.1.2.3.51.2.2.5.2.75 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistOtherMMInstalled OBJECT-TYPE Indicates whether a redundant MM is installed. | 1.3.6.1.4.1.2.3.51.2.2.5.2.76 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistOtherMMCommunicating OBJECT-TYPE Indicates whether a redundant MM is communicating. | 1.3.6.1.4.1.2.3.51.2.2.5.2.77 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bistPowerModulesInstalled OBJECT-TYPE The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.81 | OCTET STRING | read-only | mandatory |
| bistPowerModulesFunctional OBJECT-TYPE The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.2.89 | OCTET STRING | read-only | mandatory |
| bistSwitchModulesInstalled OBJECT-TYPE The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | 1.3.6.1.4.1.2.3.51.2.2.5.2.97 | OCTET STRING | read-only | mandatory |
| bistSwitchModulesCommunicating OBJECT-TYPE The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | 1.3.6.1.4.1.2.3.51.2.2.5.2.113 | OCTET STRING | read-only | mandatory |
| bistLastUpdate OBJECT-TYPE It is the time when the primary MM updated the last BIST results. | 1.3.6.1.4.1.2.3.51.2.2.5.2.200 | OCTET STRING | read-only | mandatory |
| rmmBistAndChassisStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.5.3 | |||
| rbistRs485Port1 OBJECT-TYPE Standby MM BIST RS 485 legacy test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.2 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistRs485Port2 OBJECT-TYPE Standby MM BIST RS 485 local bus test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.3 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistRtc OBJECT-TYPE Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.5 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistLocalI2CBus OBJECT-TYPE Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.7 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistPrimaryMainAppFlashImage OBJECT-TYPE Standby MM BIST Primary Main Application Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.8 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistSecondaryMainAppFlashImage OBJECT-TYPE Standby MM BIST Secondary Main Application test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.9 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistBootRomFlashImage OBJECT-TYPE Standby MM BIST Boot Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.10 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistEthernetPort1 OBJECT-TYPE Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.11 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistExternalI2CDevices OBJECT-TYPE Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.14 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistInternalEthernetSwitch OBJECT-TYPE Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.19 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistVideoCapture OBJECT-TYPE Standby MM BIST video capture test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.20 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistUSBKeyboardMouseEmulation OBJECT-TYPE Standby MM BIST USB keyboard and mouse test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.21 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistUSBMassStorageEmulation OBJECT-TYPE Standby MM BIST mass storage emulation test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.22 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistUSBKeyboardMouseFirmware OBJECT-TYPE Standby MM BIST USB keyboard and mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.23 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistUSBMassStorageFirmware OBJECT-TYPE Standby MM BIST USB keyboard mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.24 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistPrimaryCore OBJECT-TYPE Standby MM BIST primary core test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.25 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistSecondaryCore OBJECT-TYPE Standby MM BIST secondary core test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.26 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistInternalIOExpander OBJECT-TYPE Standby MM BIST internal IO expander test result. The time of the last update can be obtained by querying rbistUpdateTime object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.27 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistRemoteControlFirmware OBJECT-TYPE Standby MM BIST Remote Control firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.28 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistPhysicalNetworkLink OBJECT-TYPE Standby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.29 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistLogicalNetworkLink OBJECT-TYPE Standby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.30 | INTEGER {testSucceeded(0), testFailed(1)} | read-only | mandatory |
| rbistBladesInstalled OBJECT-TYPE The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.33 | OCTET STRING | read-only | mandatory |
| rbistBladesCommunicating OBJECT-TYPE The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.49 | OCTET STRING | read-only | mandatory |
| rbistBlowersInstalled OBJECT-TYPE The blowers that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.5.3.65 | OCTET STRING | read-only | mandatory |
| rbistBlowersFunctional OBJECT-TYPE The blowers installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.5.3.73 | OCTET STRING | read-only | mandatory |
| rbistMediaTrayInstalled OBJECT-TYPE Indicates whether a media tray was installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.74 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistMediaTrayCommunicating OBJECT-TYPE Indicates whether a media tray was communicating when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.75 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistOtherMMInstalled OBJECT-TYPE Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object. | 1.3.6.1.4.1.2.3.51.2.2.5.3.76 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistOtherMMCommunicating OBJECT-TYPE Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.77 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| rbistPowerModulesInstalled OBJECT-TYPE The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.81 | OCTET STRING | read-only | mandatory |
| rbistPowerModulesFunctional OBJECT-TYPE The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.2.5.3.89 | OCTET STRING | read-only | mandatory |
| rbistSwitchModulesInstalled OBJECT-TYPE The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | 1.3.6.1.4.1.2.3.51.2.2.5.3.97 | OCTET STRING | read-only | mandatory |
| rbistSwitchModulesCommunicating OBJECT-TYPE The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | 1.3.6.1.4.1.2.3.51.2.2.5.3.113 | OCTET STRING | read-only | mandatory |
| rbistUpdateTime OBJECT-TYPE It is the time when the standby MM updated the last BIST results. | 1.3.6.1.4.1.2.3.51.2.2.5.3.200 | OCTET STRING | read-only | mandatory |
| rbistLastUpdatePrimary OBJECT-TYPE It is the time when the standby MM updated the last BIST results when it was still primary. | 1.3.6.1.4.1.2.3.51.2.2.5.3.201 | OCTET STRING | read-only | mandatory |
| fanPack OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.6 | |||
| fanPackTable OBJECT-TYPE Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.6.1 | not-accessible | mandatory | |
| fanPackEntry OBJECT-TYPE Fan Pack entry | 1.3.6.1.4.1.2.3.51.2.2.6.1.1 | not-accessible | mandatory | |
| fanPackIndex OBJECT-TYPE Fan Pack sequence index. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.1 | INTEGER | read-only | mandatory |
| fanPackExists OBJECT-TYPE Indicates whether the fan pack specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| fanPackState OBJECT-TYPE The health state for the fan pack. 0 = unknown, 1 = good, 2 = warning, 3 = bad. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.3 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| fanPackFanCount OBJECT-TYPE The number of fans in the fan pack. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.4 | INTEGER {unknown(255)} | read-only | mandatory |
| fanPackAverageSpeed OBJECT-TYPE The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.5 | OCTET STRING | read-only | mandatory |
| fanPackAverageSpeedRPM OBJECT-TYPE The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.6 | OCTET STRING | read-only | mandatory |
| fanPackControllerState OBJECT-TYPE The health state for the controller for the fan pack. 0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error, 255 = unknown | 1.3.6.1.4.1.2.3.51.2.2.6.1.1.7 | INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)} | read-only | mandatory |
| systemHealth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.7 | |||
| systemHealthStat OBJECT-TYPE Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally. | 1.3.6.1.4.1.2.3.51.2.2.7.1 | INTEGER {critical(0), nonCritical(2), systemLevel(4), normal(255)} | read-only | mandatory |
| systemHealthSummaryTable OBJECT-TYPE Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2 | not-accessible | mandatory | |
| systemHealthSummaryEntry OBJECT-TYPE System Health Summary entry NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1 | not-accessible | mandatory | |
| systemHealthSummaryIndex OBJECT-TYPE System health summary index. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.1 | INTEGER | read-only | mandatory |
| systemHealthSummarySeverity OBJECT-TYPE System health summary severity. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.2 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryDescription OBJECT-TYPE System health summary description. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.3 | OCTET STRING | read-only | mandatory |
| systemHealthSummaryDateTime OBJECT-TYPE System health summary date time. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.7.2.1.4 | OCTET STRING | read-only | mandatory |
| leds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8 | |||
| frontPanelLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.1 | |||
| systemErrorLED OBJECT-TYPE Indicates whether the front panel system error LED is on or off. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.8.1.1 | INTEGER {off(0), on(1)} | read-only | mandatory |
| informationLED OBJECT-TYPE Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.8.1.2 | INTEGER {off(0), on(1)} | read-write | mandatory |
| temperatureLED OBJECT-TYPE Indicates whether the front panel temperature LED is on or off. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.8.1.3 | INTEGER {off(0), on(1)} | read-only | mandatory |
| identityLED OBJECT-TYPE Indicates whether the front panel identity LED is on or off. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.8.1.4 | INTEGER {off(0), on(1), blinking(2), notAvailable(3)} | read-write | mandatory |
| bladeLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.2 | |||
| bladeLEDsTable OBJECT-TYPE Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1 | not-accessible | mandatory | |
| bladeLEDsEntry OBJECT-TYPE Blade system status entry | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1 | not-accessible | mandatory | |
| ledBladeIndex OBJECT-TYPE Blade LED table index. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1 | INTEGER | read-only | mandatory |
| ledBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| ledBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| ledBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)} | read-only | mandatory |
| ledBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6 | OCTET STRING | read-only | mandatory |
| ledBladeSystemError OBJECT-TYPE Indicates whether the blade system error LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7 | INTEGER {off(0), on(1)} | read-only | mandatory |
| ledBladeInformation OBJECT-TYPE Indicates whether the blade information LED is on or off. For Write access, the LED can be turned off only. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8 | INTEGER {off(0), on(1)} | read-write | mandatory |
| ledBladeKVM OBJECT-TYPE Indicates whether the blade KVM LED is on, off, or blinking. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.9 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| ledBladeMediaTray OBJECT-TYPE Indicates whether the blade media tray LED is on, off, or blinking. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.10 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| ledBladeIdentity OBJECT-TYPE Indicates whether the blade identify LED is on, off, or blinking. | 1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11 | INTEGER {off(0), on(1), blinking(2)} | read-write | mandatory |
| bladeLEDsDetailsTable OBJECT-TYPE Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2 | not-accessible | mandatory | |
| bladeLEDsDetailsEntry OBJECT-TYPE Blade LEDs Details entry | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1 | not-accessible | mandatory | |
| ledIndex OBJECT-TYPE The LED index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1 | INTEGER | read-only | mandatory |
| ledBladeBayNumber OBJECT-TYPE The bay number of the main server blade that the LED is grouped into. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2 | OCTET STRING | read-only | mandatory |
| ledBladeComponentType OBJECT-TYPE Type of the component/subcomponent grouping for this LED. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3 | OCTET STRING | read-only | mandatory |
| ledBladeLabel OBJECT-TYPE Text label for a LED. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4 | OCTET STRING | read-only | mandatory |
| ledBladeState OBJECT-TYPE Text description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| ledBladeLocation OBJECT-TYPE Location of this LED. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6 | OCTET STRING | read-only | mandatory |
| telcoPanelLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.3 | |||
| criticalLED OBJECT-TYPE Indicates whether the BladeCenter T Panel CRT (Critical) LED is on or off. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.1 | INTEGER {off(0), on(1)} | read-only | mandatory |
| majorLED OBJECT-TYPE Indicates whether the BladeCenter T Panel MJR (Major) LED is on or off. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.2 | INTEGER {off(0), on(1)} | read-only | mandatory |
| minorLED OBJECT-TYPE Indicates whether the BladeCenter T Panel MNR (Minor) LED is on or off. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.3 | INTEGER {off(0), on(1)} | read-only | mandatory |
| telcoIdentityLED OBJECT-TYPE Indicates whether the BladeCenter T Panel identity LED is on or off. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.4 | INTEGER {off(0), on(1), blinking(2), notAvailable(3)} | read-write | mandatory |
| telcoColorSel OBJECT-TYPE Indicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.5 | INTEGER {amber(0), red(1)} | read-write | mandatory |
| criticalityAssertionMode OBJECT-TYPE Indicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.8.3.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.4 | |||
| smLEDsTable OBJECT-TYPE Table of switch module LEDs information. | 1.3.6.1.4.1.2.3.51.2.2.8.4.1 | not-accessible | mandatory | |
| smLEDsEntry OBJECT-TYPE Switch module LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1 | not-accessible | mandatory | |
| ledSMIndex OBJECT-TYPE Switch module LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledSMLEDs OBJECT-TYPE A bitmap of LEDs information on the selected switch module. The bitmap is a string containing a list of 1's and 0's. Every 4 bytes are used to represent a led state. The first 64 bytes represent the status of the external LEDs while the last 64 bytes represent the status of the internal port connections from the switch module to blades. Each nibble of data is presented in the bitmap format (0000) and is encoded as followed - 0000: LED is not present - 0001: LED is off - 0010: LED is on NOTE: The data is read from left to right, starting out with blade server 1 and so on. | 1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.2 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| blowerLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.5 | |||
| blowerLEDsTable OBJECT-TYPE Table of blower LEDs information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1 | not-accessible | mandatory | |
| blowerLEDsEntry OBJECT-TYPE Blower LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1 | not-accessible | mandatory | |
| ledBlowerIndex OBJECT-TYPE Blower LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledBlowerId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2 | INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)} | read-only | mandatory |
| ledBlowerExists OBJECT-TYPE Indicates whether the blower specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledBlowerError OBJECT-TYPE Indicates whether the blower error LED is on, off, or not available. | 1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4 | INTEGER {off(0), on(1), notAvailable(2)} | read-only | mandatory |
| fanPackLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.6 | |||
| fanPackLEDsTable OBJECT-TYPE Table of fan pack LEDs information. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1 | not-accessible | mandatory | |
| fanPackLEDsEntry OBJECT-TYPE Fan Pack LEDs information entry | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1 | not-accessible | mandatory | |
| ledFanPackIndex OBJECT-TYPE Fan Pack LEDs table index. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledFanPackId OBJECT-TYPE The numeric fan pack ID. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2 | INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4)} | read-only | mandatory |
| ledFanPackExists OBJECT-TYPE Indicates whether the fan pack specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3 | INTEGER (0..128) | read-only | mandatory |
| ledFanPackError OBJECT-TYPE Indicates whether the fan pack error LED is on or off. | 1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4 | INTEGER (0..128) | read-only | mandatory |
| mtStatusLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.7 | |||
| mtStatusLEDsTable OBJECT-TYPE Table of Media Tray Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1 | not-accessible | mandatory | |
| mtStatusLEDsEntry OBJECT-TYPE Media Tray Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1 | not-accessible | mandatory | |
| ledMediaTrayIndex OBJECT-TYPE Media Tray Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledMediaTrayId OBJECT-TYPE The numeric Media Tray ID. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.2 | INTEGER {topmediatray(1), botmediatray(2)} | read-only | mandatory |
| ledMediaTrayExists OBJECT-TYPE Indicates whether the Media Tray exists or not. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledMediaTrayFault OBJECT-TYPE Indicates whether the Media Tray Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.5 | INTEGER {off(0), on(1)} | read-only | mandatory |
| tapStatusLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.8 | |||
| tapExists OBJECT-TYPE Indicates whether the Alarm Panel exists or not. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.8.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| tapFRRLED OBJECT-TYPE Indicates whether the Alarm Panel Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.8.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| tapFaultLED OBJECT-TYPE Indicates whether the Alarm Panel Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.8.5 | INTEGER {off(0), on(1)} | read-only | mandatory |
| ncStatusLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.9 | |||
| ncStatusLEDsTable OBJECT-TYPE Table of Network Clock Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1 | not-accessible | deprecated | |
| ncStatusLEDsEntry OBJECT-TYPE Network Clock Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1 | not-accessible | deprecated | |
| ledNetworkClockIndex OBJECT-TYPE Network Clock Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.1 | INTEGER (0..128) | read-only | deprecated |
| ledNetworkClockId OBJECT-TYPE The numeric Network Clock ID. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.2 | INTEGER {networkclock1(1), networkclock2(2)} | read-only | deprecated |
| ledNetworkClockExists OBJECT-TYPE Indicates whether the Network Clock exists or not. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.3 | INTEGER {false(0), true(1)} | read-only | deprecated |
| ledNetworkClockFRR OBJECT-TYPE Indicates whether the Network Clock Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.4 | INTEGER {off(0), on(1)} | read-only | deprecated |
| ledNetworkClockFault OBJECT-TYPE Indicates whether the Network Clock Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.5 | INTEGER {off(0), on(1)} | read-only | deprecated |
| mxStatusLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.10 | |||
| mxStatusLEDsTable OBJECT-TYPE Table of Multiplexer Expansion Module Status LEDs information. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1 | not-accessible | mandatory | |
| mxStatusLEDsEntry OBJECT-TYPE Multiplexer Expansion Module Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1 | not-accessible | mandatory | |
| ledMuxIndex OBJECT-TYPE Multiplexer Expansion Module Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.1 | INTEGER (0..128) | read-only | mandatory |
| ledMuxId OBJECT-TYPE The numeric Multiplexer Expansion Module ID. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.2 | INTEGER {mux1(1), mux2(2)} | read-only | mandatory |
| ledMuxExists OBJECT-TYPE Indicates whether the Multiplexer Expansion Module exists or not. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledMuxFRR OBJECT-TYPE Indicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| ledMuxFault OBJECT-TYPE Indicates whether the Multiplexer Expansion Module Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.5 | INTEGER {off(0), on(1)} | read-only | mandatory |
| storageLEDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.8.11 | |||
| storageLEDsTable OBJECT-TYPE Table of storage module LEDs information. NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1 | not-accessible | mandatory | |
| storageLEDsEntry OBJECT-TYPE Storage Module LEDs information entry NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1 | not-accessible | mandatory | |
| ledStorageIndex OBJECT-TYPE Storage Module LEDs table index. NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.1 | INTEGER | read-only | mandatory |
| ledStorageId OBJECT-TYPE The numeric storage module ID. NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.2 | INTEGER {storage1(1), storage2(2)} | read-only | mandatory |
| ledStorageExists OBJECT-TYPE Indicates whether the storage module specified exists or not. NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| ledStorageError OBJECT-TYPE Indicates the status of the storage module error LED. NOTE: This MIB object is for BladeCenter S only. | 1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.4 | INTEGER {off(0), on(1), blinking(2)} | read-only | mandatory |
| telcoSystemHealth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.9 | |||
| telcoSystemHealthStat OBJECT-TYPE Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a non-recoverable service affecting condition has occurred that requires an immediate action. A value of 'major' indicates a critical service affecting condition has occurred that requires an urgent action. A value of 'minor' indicates a non-service affecting condition has occurred. Corrective action should be taken in order to prevent a more serious fault. A value of 'normal' indicates that the system is operating normally. Severity level with '-power' indicates the failure relates to the power resource. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.9.1 | INTEGER {minor(1), minor-power(2), major(3), major-power(4), critical(5), critical-power(6), normal(255)} | read-only | mandatory |
| telcoSystemHealthSummaryTable OBJECT-TYPE Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter T only. NOTE: This table may contain one entry if no alarms are in progress. That one entry, if present, contains no alarms but a message of 'Good' in the severity object. | 1.3.6.1.4.1.2.3.51.2.2.9.2 | not-accessible | mandatory | |
| telcoSystemHealthSummaryEntry OBJECT-TYPE BladeCenter T System Health Summary entry. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1 | not-accessible | mandatory | |
| telcoSystemHealthSummaryIndex OBJECT-TYPE BladeCenter T System Health Summary Index. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.1 | INTEGER | read-only | mandatory |
| telcoSystemHealthSummarySeverity OBJECT-TYPE BladeCenter T System Health Summary Severity. The values and meanings are as follows: 0x06 Critical-Power 0x05 Critical 0x04 Major-Power 0x03 Major 0x02 Minor-Power 0x01 Minor 0xFF Normal NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'Good'. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.2 | OCTET STRING | read-only | mandatory |
| telcoSystemHealthSummaryDescription OBJECT-TYPE BladeCenter T System Health Summary Description. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.3 | OCTET STRING | read-only | mandatory |
| telcoSystemHealthSummaryEventName OBJECT-TYPE BladeCenter T System Health Summary Event Name. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.4 | INTEGER | read-only | mandatory |
| telcoSystemHealthSummaryEventKeyID OBJECT-TYPE BladeCenter T System Health Summary Event Key ID. An octet string expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.5 | OCTET STRING | read-only | mandatory |
| telcoSystemHealthSummaryAcknowledge OBJECT-TYPE BladeCenter T System Health Summary Acknowledge. Indicates whether the alarm event is acknowledged or unacknowledged. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.6 | INTEGER {unacknowledged(0), acknowledged(1)} | read-only | mandatory |
| telcoSystemHealthSummaryAssertTime OBJECT-TYPE BladeCenter T System Health Summary Assert Time. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'. | 1.3.6.1.4.1.2.3.51.2.2.9.2.1.7 | OCTET STRING | read-only | mandatory |
| fuelGauge OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10 | |||
| fuelGaugeInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.1 | |||
| fuelGaugeTable OBJECT-TYPE Table of Fuel Gauge information. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1 | not-accessible | mandatory | |
| fuelGaugeEntry OBJECT-TYPE Fuel Gauge entry | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1 | not-accessible | mandatory | |
| fuelGaugeIndex OBJECT-TYPE Fuel Gauge Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1 | INTEGER | read-only | mandatory |
| fuelGaugePowerDomainNumber OBJECT-TYPE Fuel Gauge Table Power Domain Number. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2 | INTEGER {powerDomain1(1), powerDomain2(2)} | read-only | mandatory |
| fuelGaugeStatus OBJECT-TYPE Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3 | OCTET STRING | read-only | mandatory |
| fuelGaugeFirstPowerModule OBJECT-TYPE Fuel Gauge Table First Power Module capacity in Watts in the power domain. NOTE: First power module in power domain 1 and 2 is in bay 1 and 3 respectively. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4 | OCTET STRING | read-only | mandatory |
| fuelGaugeSecondPowerModule OBJECT-TYPE Fuel Gauge Table Second Power Module capacity in Watts in the power domain. NOTE: Second power module in power domain 1 and 2 is in bay 2 and 4 respectively. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5 | OCTET STRING | read-only | mandatory |
| fuelGaugePowerManagementPolicySetting OBJECT-TYPE Fuel Gauge Table for the Power Management Policy Setting for each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. In addition, note that the first three enumerated choices above are referred to with updated nomenclature, as follows: redundantWithoutPerformanceImpact(0) equals Redundant Power Modules redundantWithPerformanceImpact(1) equals Power Modules with Blade Throttling Allowed nonRedundant(2) equals Basic Power Management | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6 | INTEGER {redundantWithoutPerformanceImpact(0), redundantWithPerformanceImpact(1), nonRedundant(2), redundantACPowerSource(3), acPowerSourceWithBladeThrottlingAllowed(4), notApplicable(255)} | read-only | mandatory |
| fuelGaugeTotalPower OBJECT-TYPE This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7 | OCTET STRING | read-only | mandatory |
| fuelGaugeAllocatedPower OBJECT-TYPE This field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and 4 (Powered on or standby). 3) Power is reserved for each installed Blade. Blades in a standby state (not powered on) will reserve a certain amount power. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8 | OCTET STRING | read-only | mandatory |
| fuelGaugeRemainingPower OBJECT-TYPE This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9 | OCTET STRING | read-only | mandatory |
| fuelGaugePowerInUsed OBJECT-TYPE This field displays the total power being used in each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10 | OCTET STRING | read-only | mandatory |
| powerDomain1 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.2 | |||
| powerDomain1Table OBJECT-TYPE Table of Power Domain 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1 | not-accessible | mandatory | |
| powerDomain1Entry OBJECT-TYPE Fuel Gauge entry | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1 | not-accessible | mandatory | |
| pd1Index OBJECT-TYPE Power Domain 1 Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 | INTEGER | read-only | mandatory |
| pd1BayNumber OBJECT-TYPE Power Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), managementModuleBay1(5), managementModuleBay2(6), switchModuleBay1(7), switchModuleBay2(8), switchModuleBay3(9), switchModuleBay4(10), serverBladeBay1(11), serverBladeBay2(12), serverBladeBay3(13), serverBladeBay4(14), serverBladeBay5(15), serverBladeBay6(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay1(17), serverBladeBay2(18), serverBladeBay3(19), serverBladeBay4(20), serverBladeBay5(21), serverBladeBay6(22), serverBladeBay7(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), blowerBay3(5) (if Power Domain 2 is not available), blowerBay4(6) (if Power Domain 2 is not available), managementModuleBay1(7), managementModuleBay2(8), switchModuleBay1(9), switchModuleBay2(10), switchModuleBay3(11), switchModuleBay4(12), serverBladeBay1(13), serverBladeBay2(14), serverBladeBay3(15), serverBladeBay4(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter HT: notApplicable(1), mediatrayBay1(2), mediatrayBay2(3), fanPackBay1(4), fanPackBay2(5), fanPackBay3(6), fanPackBay4(7), blowerBay1(8), blowerBay2(9), blowerBay3(10), blowerBay4(11), networkclockBay1(12), networkclockBay2(13), midplaneelectroBay1(14), midplaneelectroBay2(15), notApplicable(16), managementModuleBay1(17), managementModuleBay2(18), ioModuleBay1(19), ioModuleBay2(20), ioModuleBay3(21), ioModuleBay4(22), serverBladeBay1(23), serverBladeBay2(24), serverBladeBay3(25), serverBladeBay4(26), serverBladeBay5(27), serverBladeBay6(28), notApplicable(29) The following Bay Number IDs are used in the BladeCenter S: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), blowerBay1(7), blowerBay2(8), blowerBay3(9), blowerBay4(10), storageModuleBay1(11), storageModuleBay2(12), managementModuleBay(13), ioModuleBay1(14), ioModuleBay2(15), ioModuleBay3(16), ioModuleBay4(17), serverBladeBay1(18), serverBladeBay2(19), serverBladeBay3(20), serverBladeBay4(21), serverBladeBay5(22), serverBladeBay6(23), notApplicable(24) | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 | OCTET STRING | read-only | mandatory |
| pd1BladePrimarySlot OBJECT-TYPE Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd1ModuleStatus OBJECT-TYPE Power Domain 1 Table Module Throttle Status. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 | INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)} | read-only | mandatory |
| pd1ModuleName OBJECT-TYPE Power Domain 1 Table Module Name. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 | OCTET STRING | read-only | mandatory |
| pd1ModuleState OBJECT-TYPE Power Domain 1 Table Module State. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 | INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)} | read-only | mandatory |
| pd1ModuleAllocatedPowerCurrent OBJECT-TYPE Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 | OCTET STRING | read-only | mandatory |
| pd1ModuleAllocatedPowerMax OBJECT-TYPE Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 | OCTET STRING | read-only | mandatory |
| pd1ModuleAllocatedPowerMin OBJECT-TYPE Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 | OCTET STRING | read-only | mandatory |
| pd1ModuleCPUDutyCycles OBJECT-TYPE Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 | OCTET STRING | read-only | mandatory |
| pd1ModuleThrottle OBJECT-TYPE Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd1ModulePowerCapabilities OBJECT-TYPE Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 | INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)} | read-only | mandatory |
| pd1ModuleMeasuredOrStatic OBJECT-TYPE Power Domain 1 Table Module Measured Or Static. | 1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 | INTEGER {static(0), measured(1), notApplicable(255)} | read-only | mandatory |
| powerDomain1PowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.2.3 | |||
| pd1PowerTrendingPeriod OBJECT-TYPE Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| pd1PowerTrendingSampleTable OBJECT-TYPE Table of Power Domain 1 Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10 | not-accessible | mandatory | |
| pd1PowerTrendingSampleEntry OBJECT-TYPE Power Domain 1 Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1 | not-accessible | mandatory | |
| pd1PowerTrendingSampleIndex OBJECT-TYPE Power Domain 1 Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1 | INTEGER | read-only | mandatory |
| pd1PowerTrendingSampleTimeStamp OBJECT-TYPE Power Domain 1 Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2 | OCTET STRING | read-only | mandatory |
| pd1PowerTrendingSampleAve OBJECT-TYPE Power Domain 1 Power Trending Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3 | OCTET STRING | read-only | mandatory |
| powerDomain2 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.3 | |||
| powerDomain2Table OBJECT-TYPE Table of Power Domain 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1 | not-accessible | mandatory | |
| powerDomain2Entry OBJECT-TYPE Fuel Gauge entry | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1 | not-accessible | mandatory | |
| pd2Index OBJECT-TYPE Power Domain 2 Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.1 | INTEGER | read-only | mandatory |
| pd2BayNumber OBJECT-TYPE Power Domain 2 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: serverBladeBay7(1), serverBladeBay8(2), serverBladeBay9(3), serverBladeBay10(4), serverBladeBay11(5), serverBladeBay12(6), serverBladeBay13(7), serverBladeBay14(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay8(17), serverBladeBay9(18), serverBladeBay10(19), serverBladeBay11(20), serverBladeBay12(21), serverBladeBay13(22), serverBladeBay14(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: blowerBay3(1), blowerBay4(2), serverBladeBay5(3), serverBladeBay6(4), serverBladeBay7(5), serverBladeBay8(6), notApplicable(7), notApplicable(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter HT: fanPackBay1(1), fanPackBay2(2), fanPackBay3(3), fanPackBay4(4), blowerBay1(5), blowerBay2(6), blowerBay3(7), blowerBay4(8), ioModuleBay7(9), ioModuleBay8(10), ioModuleBay9(11), ioModuleBay10(12), serverBladeBay7(13), serverBladeBay8(14), serverBladeBay9(15), serverBladeBay10(16), serverBladeBay11(17), serverBladeBay12(18), notApplicable(19) | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.2 | OCTET STRING | read-only | mandatory |
| pd2BladePrimarySlot OBJECT-TYPE Power Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd2ModuleStatus OBJECT-TYPE Power Domain 2 Table Module throttle status. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.4 | INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)} | read-only | mandatory |
| pd2ModuleName OBJECT-TYPE Power Domain 2 Table Module Name. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.5 | OCTET STRING | read-only | mandatory |
| pd2ModuleState OBJECT-TYPE Power Domain 2 Table Power State. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.6 | INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)} | read-only | mandatory |
| pd2ModuleAllocatedPowerCurrent OBJECT-TYPE Power Domain 2 Table Allocated Power Current indicates the current power allocation for the module. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.7 | OCTET STRING | read-only | mandatory |
| pd2ModuleAllocatedPowerMax OBJECT-TYPE Power Domain 2 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.8 | OCTET STRING | read-only | mandatory |
| pd2ModuleAllocatedPowerMin OBJECT-TYPE Power Domain 2 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.9 | OCTET STRING | read-only | mandatory |
| pd2ModuleCPUDutyCycles OBJECT-TYPE Power Domain 2 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.10 | OCTET STRING | read-only | mandatory |
| pd2ModuleThrottle OBJECT-TYPE Power Domain 2 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.11 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| pd2ModulePowerCapabilities OBJECT-TYPE Power Domain 2 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.12 | INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)} | read-only | mandatory |
| pd2ModuleMeasuredOrStatic OBJECT-TYPE Power Domain 2 Table Module Measured Or Static. | 1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.13 | INTEGER {static(0), measured(1), notApplicable(255)} | read-only | mandatory |
| powerDomain2PowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.3.3 | |||
| pd2PowerTrendingPeriod OBJECT-TYPE Specify time period for power domain 2 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| pd2PowerTrendingSampleTable OBJECT-TYPE Table of Power Domain 2 Power Trending Sample Information. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10 | not-accessible | mandatory | |
| pd2PowerTrendingSampleEntry OBJECT-TYPE Power Domain 2 Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1 | not-accessible | mandatory | |
| pd2PowerTrendingSampleIndex OBJECT-TYPE Power Domain 2 Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.1 | INTEGER | read-only | mandatory |
| pd2PowerTrendingSampleTimeStamp OBJECT-TYPE Power Domain 2 Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.2 | OCTET STRING | read-only | mandatory |
| pd2PowerTrendingSampleAve OBJECT-TYPE Power Domain 2 Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.3 | OCTET STRING | read-only | mandatory |
| moduleInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4 | |||
| bladeDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.1 | |||
| bladeDetailsTable OBJECT-TYPE Table of Blade Module Details. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1 | not-accessible | mandatory | |
| bladeDetailsEntry OBJECT-TYPE Blade Module Details entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1 | not-accessible | mandatory | |
| bladeDetailsIndex OBJECT-TYPE Blade Module Details Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1 | INTEGER | read-only | mandatory |
| bladeDetailsId OBJECT-TYPE Blade Module Details Table Blade Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeDetailsMaxPowerConfig OBJECT-TYPE Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3 | INTEGER | read-write | mandatory |
| bladeDetailsEffectiveClockRate OBJECT-TYPE Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4 | OCTET STRING | read-only | mandatory |
| bladeDetailsMaximumClockRate OBJECT-TYPE Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5 | OCTET STRING | read-only | mandatory |
| bladeDetailsPowerSaverMode OBJECT-TYPE When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsDynamicPowerSaver OBJECT-TYPE When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsDynamicPowerFavorPerformanceOverPower OBJECT-TYPE When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8 | INTEGER {disable(0), enable(1), notApplicable(255)} | read-write | mandatory |
| bladeDetailsPowerControl OBJECT-TYPE This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9 | INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)} | read-write | mandatory |
| bladePowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3 | |||
| bladePowerTrendingPeriod OBJECT-TYPE Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| bladePowerTrendingBladeId OBJECT-TYPE Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-write | mandatory |
| bladePowerTrendingSampleTable OBJECT-TYPE Table of Blade Module Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10 | not-accessible | mandatory | |
| bladePowerTrendingSampleEntry OBJECT-TYPE Blade Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1 | not-accessible | mandatory | |
| bladePowerTrendingSampleIndex OBJECT-TYPE Blade Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1 | INTEGER | read-only | mandatory |
| bladePowerTrendingSampleId OBJECT-TYPE Blade Module Power Trending Sample Table Blade Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladePowerTrendingSampleTimeStamp OBJECT-TYPE Blade Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleMax OBJECT-TYPE Blade Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleMin OBJECT-TYPE Blade Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5 | OCTET STRING | read-only | mandatory |
| bladePowerTrendingSampleAve OBJECT-TYPE Blade Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6 | OCTET STRING | read-only | mandatory |
| switchDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.2 | |||
| switchPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3 | |||
| switchPowerTrendingPeriod OBJECT-TYPE Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| switchPowerTrendingSwitchId OBJECT-TYPE Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-write | mandatory |
| switchPowerTrendingSampleTable OBJECT-TYPE Table of Switch Module Power Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10 | not-accessible | mandatory | |
| switchPowerTrendingSampleEntry OBJECT-TYPE Switch Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1 | not-accessible | mandatory | |
| switchPowerTrendingSampleIndex OBJECT-TYPE Switch Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1 | INTEGER | read-only | mandatory |
| switchPowerTrendingSampleId OBJECT-TYPE Switch Module Power Trending Sample Table Switch Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| switchPowerTrendingSampleTimeStamp OBJECT-TYPE Switch Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleMax OBJECT-TYPE Switch Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleMin OBJECT-TYPE Switch Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5 | OCTET STRING | read-only | mandatory |
| switchPowerTrendingSampleAve OBJECT-TYPE Switch Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6 | OCTET STRING | read-only | mandatory |
| blowerDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.3 | |||
| blowerPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3 | |||
| blowerPowerTrendingPeriod OBJECT-TYPE Specify time period for blower module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blower Module. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| blowerPowerTrendingBlowerId OBJECT-TYPE Blower Module Power Trending Blower Id. NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2 | INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)} | read-write | mandatory |
| blowerPowerTrendingSampleTable OBJECT-TYPE Table of Blower Module Power Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10 | not-accessible | mandatory | |
| blowerPowerTrendingSampleEntry OBJECT-TYPE Blower Module Power Trending Sample entry. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1 | not-accessible | mandatory | |
| blowerPowerTrendingSampleIndex OBJECT-TYPE Blower Module Power Trending Sample Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1 | INTEGER | read-only | mandatory |
| blowerPowerTrendingSampleId OBJECT-TYPE Blower Module Power Trending Sample Table Blower Id. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2 | INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)} | read-only | mandatory |
| blowerPowerTrendingSampleTimeStamp OBJECT-TYPE Blower Module Power Trending Sample Table Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3 | OCTET STRING | read-only | mandatory |
| blowerPowerTrendingSampleMax OBJECT-TYPE Blower Module Power Trending Sample Table Maximum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4 | OCTET STRING | read-only | mandatory |
| blowerPowerTrendingSampleMin OBJECT-TYPE Blower Module Power Trending Sample Table Minimum Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5 | OCTET STRING | read-only | mandatory |
| blowerPowerTrendingSampleAve OBJECT-TYPE Blower Module Power Trending Sample Table Average Power. | 1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6 | OCTET STRING | read-only | mandatory |
| chassisInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5 | |||
| chassisConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.1 | |||
| chassisTotalDCPowerAvailable OBJECT-TYPE Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.1 | OCTET STRING | read-only | mandatory |
| chassisTotalACPowerInUsed OBJECT-TYPE Chassis total AC power being used, which displays the total AC power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis oooling devices) for the chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.2 | OCTET STRING | read-only | mandatory |
| chassisTotalThermalOutput OBJECT-TYPE Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total AC power in use. (1 Watt = 3.412 BTU/hour). | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.3 | OCTET STRING | read-only | mandatory |
| chassisTrendingSampleInterval OBJECT-TYPE Chassis Power and Thermal Trending Sample Interval. 0 means no trending. the minimum interval is 10 minutes and the maximum is 60 minutes, in 5 minute increments. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.4 | INTEGER | read-write | mandatory |
| chassisPowerService OBJECT-TYPE The chassis power service mode. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.1.5 | INTEGER {volt110(1), volt220(2), notAvailable(255)} | read-only | mandatory |
| chassisPowerTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.3 | |||
| chassisPowerTrendingPeriod OBJECT-TYPE Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| chassisPowerTrendingSampleTable OBJECT-TYPE Table of Chassis Power Trending Sample Information in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10 | not-accessible | mandatory | |
| chassisPowerTrendingSampleEntry OBJECT-TYPE Chassis Power Trending Sample entry in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1 | not-accessible | mandatory | |
| chassisPowerTrendingSampleIndex OBJECT-TYPE Chassis Power Trending Sample Index in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1 | INTEGER | read-only | mandatory |
| chassisPowerTrendingSampleTimeStamp OBJECT-TYPE Chassis Power Trending Sample Timestamp in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2 | OCTET STRING | read-only | mandatory |
| chassisPowerTrendingSampleAve OBJECT-TYPE Chassis Power Trending Sample Average Power in specified time period. | 1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3 | OCTET STRING | read-only | mandatory |
| chassisThermalTrending OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.5.5 | |||
| chassisThermalTrendingPeriod OBJECT-TYPE Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.1 | INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)} | read-write | mandatory |
| mt1ThermalTrendingTable OBJECT-TYPE Table of Media Tray 1 Thermal Trending Information. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10 | not-accessible | mandatory | |
| mt1ThermalTrendingEntry OBJECT-TYPE Media Tray 1 Thermal Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1 | not-accessible | mandatory | |
| mt1ThermalTrendingIndex OBJECT-TYPE Media Tray 1 Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1 | INTEGER | read-only | mandatory |
| mt1ThermalTrendingTimeStamp OBJECT-TYPE Media Tray 1 Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2 | OCTET STRING | read-only | mandatory |
| mt1ThermalTrendingTemperature OBJECT-TYPE Media Tray 1 Thermal Trending Table Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3 | OCTET STRING | read-only | mandatory |
| mt2ThermalTrendingTable OBJECT-TYPE Table of Media Tray 2 Thermal Trending Information. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15 | not-accessible | mandatory | |
| mt2ThermalTrendingEntry OBJECT-TYPE Media Tray 2 Thermal Trending entry. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1 | not-accessible | mandatory | |
| mt2ThermalTrendingIndex OBJECT-TYPE Media Tray 2 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.1 | INTEGER | read-only | mandatory |
| mt2ThermalTrendingTimeStamp OBJECT-TYPE Media Tray 2 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.2 | OCTET STRING | read-only | mandatory |
| mt2ThermalTrendingTemperature OBJECT-TYPE Media Tray 2 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.3 | OCTET STRING | read-only | mandatory |
| blower1ThermalTrendingTable OBJECT-TYPE Table of Blower 1 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20 | not-accessible | mandatory | |
| blower1ThermalTrendingEntry OBJECT-TYPE Blower 1 Thermal Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1 | not-accessible | mandatory | |
| blower1ThermalTrendingIndex OBJECT-TYPE Blower 1 Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.1 | INTEGER | read-only | mandatory |
| blower1ThermalTrendingTimeStamp OBJECT-TYPE Blower 1 Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.2 | OCTET STRING | read-only | mandatory |
| blower1ThermalTrendingTemperature OBJECT-TYPE Blower 1 Thermal Trending Table Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.3 | OCTET STRING | read-only | mandatory |
| blower2ThermalTrendingTable OBJECT-TYPE Table of Blower 2 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30 | not-accessible | mandatory | |
| blower2ThermalTrendingEntry OBJECT-TYPE Blower Thermal 2 Trending entry. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1 | not-accessible | mandatory | |
| blower2ThermalTrendingIndex OBJECT-TYPE Blower 2 Thermal Trending Table Index. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.1 | INTEGER | read-only | mandatory |
| blower2ThermalTrendingTimeStamp OBJECT-TYPE Blower 2 Thermal Trending Table Sample Timestamp. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.2 | OCTET STRING | read-only | mandatory |
| blower2ThermalTrendingTemperature OBJECT-TYPE Blower 2 Thermal Trending Table Temperature. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.3 | OCTET STRING | read-only | mandatory |
| blower3ThermalTrendingTable OBJECT-TYPE Table of Blower 3 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40 | not-accessible | mandatory | |
| blower3ThermalTrendingEntry OBJECT-TYPE Blower 3 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1 | not-accessible | mandatory | |
| blower3ThermalTrendingIndex OBJECT-TYPE Blower 3 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.1 | INTEGER | read-only | mandatory |
| blower3ThermalTrendingTimeStamp OBJECT-TYPE Blower 3 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.2 | OCTET STRING | read-only | mandatory |
| blower3ThermalTrendingTemperature OBJECT-TYPE Blower 3 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.3 | OCTET STRING | read-only | mandatory |
| blower4ThermalTrendingTable OBJECT-TYPE Table of Blower 4 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50 | not-accessible | mandatory | |
| blower4ThermalTrendingEntry OBJECT-TYPE Blower 4 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1 | not-accessible | mandatory | |
| blower4ThermalTrendingIndex OBJECT-TYPE Blower 4 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.1 | INTEGER | read-only | mandatory |
| blower4ThermalTrendingTimeStamp OBJECT-TYPE Blower 4 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.2 | OCTET STRING | read-only | mandatory |
| blower4ThermalTrendingTemperature OBJECT-TYPE Blower 4 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.3 | OCTET STRING | read-only | mandatory |
| powerPolicyInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.10.6 | |||
| powerPolicyTable OBJECT-TYPE Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1 | not-accessible | mandatory | |
| powerPolicyEntry OBJECT-TYPE Power Policy Entry | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1 | not-accessible | mandatory | |
| powerPolicyIndex OBJECT-TYPE The unique idenitifier of a row in the powerPolicyTable. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1 | INTEGER | read-only | mandatory |
| powerPolicyPowerDomainNumber OBJECT-TYPE The power domain number which this row is associated with. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2 | INTEGER {powerDomain1(1), powerDomain2(2)} | read-only | mandatory |
| powerPolicyName OBJECT-TYPE The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single AC power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for AC power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. AC Power Source Redundancy Intended for dual AC power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual AC power sources, one AC power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. AC Power Source Redundancy with Blade Throttling Allowed Very similar to the AC Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one AC power source fails. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3 | OCTET STRING | read-only | mandatory |
| powerPolicyPwrSupplyFailureLimit OBJECT-TYPE The maximum number of power supplies that can fail in a chassis while still providing redundancy. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4 | INTEGER | read-only | mandatory |
| powerPolicyMaxPowerLimit OBJECT-TYPE The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5 | INTEGER | read-only | mandatory |
| powerPolicyEstimatedUtilization OBJECT-TYPE The estimated utilization (as a percentage) based on current power usage. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6 | INTEGER | read-only | mandatory |
| powerPolicyActivate OBJECT-TYPE When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the AMM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy. | 1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| frontbezel OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.12 | |||
| frontbezelExists OBJECT-TYPE Indicates whether the front bezel is installed or not. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.12.1 | INTEGER {false(0), true(1)} | read-only | mandatory |
| users OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.17 | |||
| mmUsers OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.17.1 | |||
| currentlyLoggedInTable OBJECT-TYPE Table of MM users currently logged in. NOTE: This MIB object is for AMM only. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1 | not-accessible | mandatory | |
| currentlyLoggedInEntry OBJECT-TYPE MM users currently logged in entries. NOTE: This MIB object is for AMM only. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1 | not-accessible | mandatory | |
| currentlyLoggedInEntryIndex OBJECT-TYPE Index for MM users currently logged in. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| currentlyLoggedInEntryUserId OBJECT-TYPE Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| currentlyLoggedInEntryAccMethod OBJECT-TYPE Access method for MM users currently logged in. | 1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3 | OCTET STRING (SIZE(0..32)) | read-only | mandatory |
| monitorThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.20 | |||
| voltageThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.20.2 | |||
| voltageThresholdsTable OBJECT-TYPE Table of voltage threshold entries. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1 | not-accessible | mandatory | |
| voltageThresholdsEntry OBJECT-TYPE Voltage threshold entries. NOTE: This MIB object is for BladeCenter only. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1 | not-accessible | mandatory | |
| voltageThresholdEntryIndex OBJECT-TYPE Index for voltage threshold entry. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| voltageThresholdEntryName OBJECT-TYPE Voltage threshold entry null terminated string that contains the power supply's name, for example '+5V'. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| voltageThresholdEntryCurrentValue OBJECT-TYPE Voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.3 | OCTET STRING | read-only | mandatory |
| voltageThresholdEntryWarningHighValue OBJECT-TYPE Voltage threshold reading expressed in Volts(V). If the voltage rises above this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6 | OCTET STRING | read-only | mandatory |
| voltageThresholdEntryWarningResetHighValue OBJECT-TYPE Voltage threshold reading expressed in Volts(V). If the voltage rises above this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.7 | OCTET STRING | read-only | mandatory |
| voltageThresholdEntryWarningLowValue OBJECT-TYPE Voltage threshold reading expressed in Volts(V). If the voltage drops below this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.10 | OCTET STRING | read-only | mandatory |
| voltageThresholdEntryWarningResetLowValue OBJECT-TYPE Voltage threshold reading expressed in Volts(V). If the voltage drops below this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. | 1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.11 | OCTET STRING | read-only | mandatory |
| vpdInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21 | |||
| chassisVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.1 | |||
| bladeCenterVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.1.1 | |||
| bladeCenterVpdMachineType OBJECT-TYPE Machine type VPD information (from System BIOS). This field must be four alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.1 | OCTET STRING | read-write | mandatory |
| bladeCenterVpdMachineModel OBJECT-TYPE Machine model VPD information (from System BIOS). This field must be three alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.2 | OCTET STRING | read-write | mandatory |
| bladeCenterSerialNumber OBJECT-TYPE Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.3 | OCTET STRING | read-write | mandatory |
| bladeCenterUUID OBJECT-TYPE Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.4 | OCTET STRING | read-write | mandatory |
| bladeCenterManufacturingId OBJECT-TYPE Machine chassis manufacturing ID. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.5 | OCTET STRING | read-only | mandatory |
| bladeCenterHardwareRevision OBJECT-TYPE Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.6 | INTEGER | read-only | mandatory |
| bladeCenterFruNumber OBJECT-TYPE Machine chassis FRU number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.7 | OCTET STRING | read-only | mandatory |
| bladeCenterManufDate OBJECT-TYPE Machine chassis manufacture date. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.8 | OCTET STRING | read-only | mandatory |
| bladeCenterPartNumber OBJECT-TYPE Machine chassis part number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.9 | OCTET STRING | read-only | mandatory |
| bladeCenterFruSerial OBJECT-TYPE Machine chassis FRU serial number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.10 | OCTET STRING | read-only | mandatory |
| bladeCenterManufacturingIDNumber OBJECT-TYPE Machine chassis manufacturer ID Number. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.11 | OCTET STRING | read-only | mandatory |
| bladeCenterProductId OBJECT-TYPE Machine chassis product ID. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.12 | OCTET STRING | read-only | mandatory |
| bladeCenterSubManufacturerId OBJECT-TYPE Machine chassis subsystem manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.13 | OCTET STRING | read-only | mandatory |
| bladeCenterClei OBJECT-TYPE Machine chassis Common Language Equipment Identification (CLEI). | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.14 | OCTET STRING | read-only | mandatory |
| bladeCenterDirectSerialAttach OBJECT-TYPE Presence of the Direct Serial Attach Module. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.15 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeCenterHardwareRevisionString OBJECT-TYPE Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.1.1.16 | OCTET STRING | read-only | mandatory |
| mmHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.2 | |||
| mmHardwareVpdTable OBJECT-TYPE Table of the management module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1 | not-accessible | mandatory | |
| mmHardwareVpdEntry OBJECT-TYPE Management module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1 | not-accessible | mandatory | |
| mmHardwareVpdIndex OBJECT-TYPE Management module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1 | INTEGER | read-only | mandatory |
| mmHardwareVpdBayNumber OBJECT-TYPE Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdManufacturingId OBJECT-TYPE Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdFruNumber OBJECT-TYPE Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdHardwareRevision OBJECT-TYPE Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5 | INTEGER | read-only | mandatory |
| mmHardwareVpdUuid OBJECT-TYPE Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdManufDate OBJECT-TYPE Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdPartNumber OBJECT-TYPE Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdFruSerial OBJECT-TYPE Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdManufacturingIDNumber OBJECT-TYPE Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdProductId OBJECT-TYPE Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdSubManufacturerId OBJECT-TYPE Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdClei OBJECT-TYPE Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13 | OCTET STRING | read-only | mandatory |
| mmHardwareVpdHardwareRevisionString OBJECT-TYPE Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdTable OBJECT-TYPE Table of the management module interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2 | not-accessible | mandatory | |
| mmInpHardwareVpdEntry OBJECT-TYPE Management module Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1 | not-accessible | mandatory | |
| mmInpHardwareVpdIndex OBJECT-TYPE Management module Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.1 | INTEGER | read-only | mandatory |
| mmInpHardwareVpdBayNumber OBJECT-TYPE Management module Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.2 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdManufacturingId OBJECT-TYPE Management module Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.3 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdFruNumber OBJECT-TYPE Management module Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.4 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdHardwareRevision OBJECT-TYPE Management module Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.5 | INTEGER | read-only | mandatory |
| mmInpHardwareVpdUuid OBJECT-TYPE Management module Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.6 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdManufDate OBJECT-TYPE Management module Interposer hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.7 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdPartNumber OBJECT-TYPE Management module Interposer hardware VPD Part number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.8 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdFruSerial OBJECT-TYPE Management module Interposer hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.9 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdManufacturingIDNumber OBJECT-TYPE Management module Interposer hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.10 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdProductId OBJECT-TYPE Management module Interposer hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.11 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdSubManufacturerId OBJECT-TYPE Management module Interposer hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.12 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdClei OBJECT-TYPE Management module Interposer hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.13 | OCTET STRING | read-only | mandatory |
| mmInpHardwareVpdHardwareRevisionString OBJECT-TYPE Management module Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.14 | OCTET STRING | read-only | mandatory |
| mmFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.3 | |||
| mmMainApplVpdTable OBJECT-TYPE Table of MM Firmware VPD. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1 | not-accessible | mandatory | |
| mmMainApplVpdEntry OBJECT-TYPE MM Firmware VPD entry. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1 | not-accessible | mandatory | |
| mmMainApplVpdIndex OBJECT-TYPE Firmware VPD index. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1 | INTEGER | read-only | mandatory |
| mmMainApplVpdName OBJECT-TYPE Firmware VPD name description. 'AMM firmware' indicates the running firmware of the MM. 'AMM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2 | OCTET STRING | read-only | mandatory |
| mmMainApplVpdBuildId OBJECT-TYPE Firmware VPD build identification. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3 | OCTET STRING | read-only | mandatory |
| mmMainApplVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4 | OCTET STRING | read-only | mandatory |
| mmMainApplVpdFilename OBJECT-TYPE Firmware VPD file name. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5 | OCTET STRING | read-only | mandatory |
| mmMainApplVpdBuildDate OBJECT-TYPE Firmware VPD build date. | 1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6 | OCTET STRING | read-only | mandatory |
| mmBootROMVpdTable OBJECT-TYPE Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2 | not-accessible | deprecated | |
| mmBootROMVpdEntry OBJECT-TYPE MM Firmware VPD entry. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1 | not-accessible | deprecated | |
| mmBootROMVpdIndex OBJECT-TYPE Firmware VPD index. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.1 | INTEGER | read-only | deprecated |
| mmBootROMVpdName OBJECT-TYPE Firmware VPD name description. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.2 | OCTET STRING | read-only | deprecated |
| mmBootROMVpdBuildId OBJECT-TYPE Firmware VPD build identification. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.3 | OCTET STRING | read-only | deprecated |
| mmBootROMVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.4 | OCTET STRING | read-only | deprecated |
| mmBootROMVpdFilename OBJECT-TYPE Firmware VPD file name. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.5 | OCTET STRING | read-only | deprecated |
| mmBootROMVpdBuildDate OBJECT-TYPE Firmware VPD build date. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.6 | OCTET STRING | read-only | deprecated |
| mmRemoteControlVpdTable OBJECT-TYPE Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3 | not-accessible | deprecated | |
| mmRemoteControlVpdEntry OBJECT-TYPE MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1 | not-accessible | deprecated | |
| mmRemoteControlVpdIndex OBJECT-TYPE Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.1 | INTEGER | read-only | deprecated |
| mmRemoteControlVpdName OBJECT-TYPE Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.2 | OCTET STRING | read-only | deprecated |
| mmRemoteControlVpdBuildId OBJECT-TYPE Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.3 | OCTET STRING | read-only | deprecated |
| mmRemoteControlVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.4 | OCTET STRING | read-only | deprecated |
| mmRemoteControlVpdFilename OBJECT-TYPE Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.5 | OCTET STRING | read-only | deprecated |
| mmRemoteControlVpdBuildDate OBJECT-TYPE Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.6 | OCTET STRING | read-only | deprecated |
| mmPS2toUSBConvVpdTable OBJECT-TYPE Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4 | not-accessible | deprecated | |
| mmPS2toUSBConvVpdEntry OBJECT-TYPE MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1 | not-accessible | deprecated | |
| mmPS2toUSBConvVpdIndex OBJECT-TYPE Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.1 | INTEGER | read-only | deprecated |
| mmPS2toUSBConvVpdName OBJECT-TYPE Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.2 | OCTET STRING | read-only | deprecated |
| mmPS2toUSBConvVpdBuildId OBJECT-TYPE Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.3 | OCTET STRING | read-only | deprecated |
| mmPS2toUSBConvVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.4 | OCTET STRING | read-only | deprecated |
| mmPS2toUSBConvVpdFilename OBJECT-TYPE Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.5 | OCTET STRING | read-only | deprecated |
| mmPS2toUSBConvVpdBuildDate OBJECT-TYPE Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.6 | OCTET STRING | read-only | deprecated |
| mmToUSBIntfVpdTable OBJECT-TYPE Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5 | not-accessible | deprecated | |
| mmToUSBIntfVpdEntry OBJECT-TYPE MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1 | not-accessible | deprecated | |
| mmToUSBIntfVpdIndex OBJECT-TYPE Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.1 | INTEGER | read-only | deprecated |
| mmToUSBIntfVpdName OBJECT-TYPE Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.2 | OCTET STRING | read-only | deprecated |
| mmToUSBIntfVpdBuildId OBJECT-TYPE Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.3 | OCTET STRING | read-only | deprecated |
| mmToUSBIntfVpdRevisonNumber OBJECT-TYPE Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.4 | OCTET STRING | read-only | deprecated |
| mmToUSBIntfVpdFilename OBJECT-TYPE Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.5 | OCTET STRING | read-only | deprecated |
| mmToUSBIntfVpdBuildDate OBJECT-TYPE Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.6 | OCTET STRING | read-only | deprecated |
| bladeHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.4 | |||
| bladeHardwareVpdTable OBJECT-TYPE Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1 | not-accessible | mandatory | |
| bladeHardwareVpdEntry OBJECT-TYPE Blade hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1 | not-accessible | mandatory | |
| bladeHardwareVpdIndex OBJECT-TYPE Blade hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1 | INTEGER | read-only | mandatory |
| bladeHardwareVpdBayNumber OBJECT-TYPE Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdManufacturingId OBJECT-TYPE Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdFruNumber OBJECT-TYPE Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdHardwareRevision OBJECT-TYPE Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5 | INTEGER | read-only | mandatory |
| bladeHardwareVpdSerialNumber OBJECT-TYPE Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdMachineType OBJECT-TYPE Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdUuid OBJECT-TYPE Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdManufDate OBJECT-TYPE Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdPartNumber OBJECT-TYPE Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdFruSerial OBJECT-TYPE Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdMachineModel OBJECT-TYPE Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdManufacturingIDNumber OBJECT-TYPE Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdProductId OBJECT-TYPE Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdSubManufacturerId OBJECT-TYPE Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdClei OBJECT-TYPE Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16 | OCTET STRING | read-only | mandatory |
| bladeHardwareVpdHardwareRevisionString OBJECT-TYPE Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdCardType OBJECT-TYPE Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20 | INTEGER {unknown(0), networkExpansion(1), storageExpansion(2), pciExpansion(3), genericExpansion(4)} | read-only | mandatory |
| bladeDaughterVpdManufacturingId OBJECT-TYPE Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdFruNumber OBJECT-TYPE Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdHardwareRevision OBJECT-TYPE Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23 | INTEGER | read-only | mandatory |
| bladeDaughterVpdSerialNumber OBJECT-TYPE Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdMachineType OBJECT-TYPE Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdUuid OBJECT-TYPE Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdManufDate OBJECT-TYPE Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdPartNumber OBJECT-TYPE Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdFruSerial OBJECT-TYPE Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdManufacturingIDNumber OBJECT-TYPE Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdProductId OBJECT-TYPE Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdSubManufacturerId OBJECT-TYPE Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdClei OBJECT-TYPE Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33 | OCTET STRING | read-only | mandatory |
| bladeDaughterVpdHardwareRevisionString OBJECT-TYPE Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34 | OCTET STRING | read-only | mandatory |
| bladeMACAddressVpdTable OBJECT-TYPE Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2 | not-accessible | mandatory | |
| bladeMACAddressVpdEntry OBJECT-TYPE Blade MAC address entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1 | not-accessible | mandatory | |
| bladeMACAddressVpdIndex OBJECT-TYPE Blade index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1 | INTEGER | read-only | mandatory |
| bladeMACAddress1Vpd OBJECT-TYPE Blade MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2 | OCTET STRING | read-only | mandatory |
| bladeMACAddress2Vpd OBJECT-TYPE Blade MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3 | OCTET STRING | read-only | mandatory |
| bladeMACAddress3Vpd OBJECT-TYPE Blade MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4 | OCTET STRING | read-only | mandatory |
| bladeMACAddress4Vpd OBJECT-TYPE Blade MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeMACAddress5Vpd OBJECT-TYPE Blade MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6 | OCTET STRING | read-only | mandatory |
| bladeMACAddress6Vpd OBJECT-TYPE Blade MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7 | OCTET STRING | read-only | mandatory |
| bladeMACAddress7Vpd OBJECT-TYPE Blade MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8 | OCTET STRING | read-only | mandatory |
| bladeMACAddress8Vpd OBJECT-TYPE Blade MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard1MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard2MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard3MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard4MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress1Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress2Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress3Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress4Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress5Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress6Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress7Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48 | OCTET STRING | read-only | mandatory |
| bladeDaughterCard5MACAddress8Vpd OBJECT-TYPE Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress1Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress2Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress3Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress4Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress5Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress6Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress7Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress8Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress9Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 9. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.108 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress10Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 10. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.109 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress11Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 11. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.110 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress12Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 12. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.111 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress13Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 13. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.112 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress14Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 14. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.113 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress15Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 15. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.114 | OCTET STRING | read-only | mandatory |
| bladeHSDaughterCard1MACAddress16Vpd OBJECT-TYPE Blade high speed expansion card (daughter card) 1 MAC address 16. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.115 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress1Vpd OBJECT-TYPE Blade side card MAC address 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress2Vpd OBJECT-TYPE Blade side card MAC address 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress3Vpd OBJECT-TYPE Blade side card MAC address 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress4Vpd OBJECT-TYPE Blade side card MAC address 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress5Vpd OBJECT-TYPE Blade side card MAC address 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress6Vpd OBJECT-TYPE Blade side card MAC address 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress7Vpd OBJECT-TYPE Blade side card MAC address 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170 | OCTET STRING | read-only | mandatory |
| bladeSideCardMACAddress8Vpd OBJECT-TYPE Blade side card MAC address 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdTable OBJECT-TYPE Table of VPD information for the blade expansion board components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3 | not-accessible | mandatory | |
| bladeExpBoardVpdEntry OBJECT-TYPE Blade expansion board VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1 | not-accessible | mandatory | |
| bladeExpBoardVpdIndex OBJECT-TYPE Blade expansion board VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.1 | INTEGER | read-only | mandatory |
| bladeExpBoardVpdBayNumber OBJECT-TYPE Blade expansion board VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.2 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdManufacturingId OBJECT-TYPE Blade expansion board VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.3 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdFruNumber OBJECT-TYPE Blade expansion board VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.4 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdHardwareRevision OBJECT-TYPE Blade expansion board VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.5 | INTEGER | read-only | mandatory |
| bladeExpBoardVpdSerialNumber OBJECT-TYPE Blade expansion board VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.6 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdMachineType OBJECT-TYPE Blade expansion board VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.7 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdUuid OBJECT-TYPE Blade expansion board VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.8 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdManufDate OBJECT-TYPE Blade expansion board VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.9 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdPartNumber OBJECT-TYPE Blade expansion board VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.10 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdFruSerial OBJECT-TYPE Blade expansion board VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.11 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdMachineModel OBJECT-TYPE Blade expansion board VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.12 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdManufacturingIDNumber OBJECT-TYPE Blade expansion board VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.13 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdProductId OBJECT-TYPE Blade expansion board VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.14 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdSubManufacturerId OBJECT-TYPE Blade expansion board VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.15 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdClei OBJECT-TYPE Blade expansion board VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.16 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdBladeBayNumber OBJECT-TYPE Blade bay number of the blade expansion board. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.19 | OCTET STRING | read-only | mandatory |
| bladeExpBoardVpdCardType OBJECT-TYPE Blade expansion board VPD type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.20 | INTEGER {unknown(0), storageExpansion(1), pciExpansion(2)} | read-only | mandatory |
| bladeExpBoardVpdCardSubType OBJECT-TYPE Blade expansion board VPD subtype. Describes the expansion board type with more granularity. bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Generations), peu1 = PCI Expansion (1st Generation), peu2 = PCI Expansion Unit II, peu3 = bpe3 = PCI Express Expansion Unit, bie= Blade I/O Expansion For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.21 | INTEGER {unknown(0), bse1(1), bse2(2), bse3(3), peu1(11), peu2(12), peu3(13), bie(21)} | read-only | mandatory |
| bladeExpBoardVpdHardwareRevisionString OBJECT-TYPE Blade expansion board VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.22 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdTable OBJECT-TYPE Table of VPD information for the blade side card components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4 | not-accessible | mandatory | |
| bladeSideCardVpdEntry OBJECT-TYPE Blade side card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1 | not-accessible | mandatory | |
| bladeSideCardVpdIndex OBJECT-TYPE Blade side card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.1 | INTEGER | read-only | mandatory |
| bladeSideCardVpdBayNumber OBJECT-TYPE Blade side card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.2 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdManufacturingId OBJECT-TYPE Blade side card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.3 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdFruNumber OBJECT-TYPE Blade side card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.4 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdHardwareRevision OBJECT-TYPE Blade side card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.5 | INTEGER | read-only | mandatory |
| bladeSideCardVpdSerialNumber OBJECT-TYPE Blade side card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.6 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdMachineType OBJECT-TYPE Blade side card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.7 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdUuid OBJECT-TYPE Blade side card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.8 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdManufDate OBJECT-TYPE Blade side card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.9 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdPartNumber OBJECT-TYPE Blade side card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.10 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdFruSerial OBJECT-TYPE Blade side card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.11 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdMachineModel OBJECT-TYPE Blade side card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.12 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdManufacturingIDNumber OBJECT-TYPE Blade side card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.13 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdProductId OBJECT-TYPE Blade side card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.14 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdSubManufacturerId OBJECT-TYPE Blade side card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.15 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdClei OBJECT-TYPE Blade side card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.16 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdBladeBayNumber OBJECT-TYPE Blade bay number of the blade side card. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.19 | OCTET STRING | read-only | mandatory |
| bladeSideCardVpdHardwareRevisionString OBJECT-TYPE Blade side card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.20 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdTable OBJECT-TYPE Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5 | not-accessible | mandatory | |
| bladeExpCardVpdEntry OBJECT-TYPE Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1 | not-accessible | mandatory | |
| bladeExpCardVpdIndex OBJECT-TYPE Blade expansion card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1 | INTEGER | read-only | mandatory |
| bladeExpCardVpdBayNumber OBJECT-TYPE Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdManufacturingId OBJECT-TYPE Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdFruNumber OBJECT-TYPE Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdHardwareRevision OBJECT-TYPE Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5 | INTEGER | read-only | mandatory |
| bladeExpCardVpdSerialNumber OBJECT-TYPE Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdMachineType OBJECT-TYPE Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdUuid OBJECT-TYPE Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdManufDate OBJECT-TYPE Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdPartNumber OBJECT-TYPE Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdFruSerial OBJECT-TYPE Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdMachineModel OBJECT-TYPE Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdManufacturingIDNumber OBJECT-TYPE Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdProductId OBJECT-TYPE Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdSubManufacturerId OBJECT-TYPE Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdClei OBJECT-TYPE Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdBladeBayNumber OBJECT-TYPE Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19 | OCTET STRING | read-only | mandatory |
| bladeExpCardVpdCardTypeInfo OBJECT-TYPE Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21 | INTEGER {unknown(0), bladeEthernetExpCard(1), bladeFiberChannelExpCard(2), serialPortExpCard(3), bladeOpticalPassThrough(4), bladeInfinibandExpCard(5), bladeIscsiExpCard(6), bladeGenericExpCard(7), bladeNetworkCFFeExpCard(8), bladeSASConnectivityCard(9), bladeSATAConnectivityCard(10), bladeNetworkCFFzExpCard(11), bladeNetworkCNAExpCard(12), bladeSSDExpCard(13), bladePCIExp(14), bladeGraphicsExp(15), bladeIOExp(16), bladeMemoryExp(17), bladeProcessorExp(18), bladeGenericExp(19)} | read-only | mandatory |
| bladeExpCardVpdHighSpeed OBJECT-TYPE Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22 | INTEGER {no(0), yes(1), notApplicable(255)} | read-only | mandatory |
| bladeExpCardVpdHardwareRevisionString OBJECT-TYPE Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdTable OBJECT-TYPE Table of VPD information for the blade concurrent keyboard, video, and mouse (cKVM) card components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6 | not-accessible | mandatory | |
| bladecKVMCardVpdEntry OBJECT-TYPE Blade concurrent keyboard, video, and mouse (cKVM) card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1 | not-accessible | mandatory | |
| bladecKVMCardVpdIndex OBJECT-TYPE Blade concurrent keyboard mouse video (cKVM) card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.1 | INTEGER | read-only | mandatory |
| bladecKVMCardVpdBayNumber OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.2 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdManufacturingId OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.3 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdFruNumber OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.4 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdHardwareRevision OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.5 | INTEGER | read-only | mandatory |
| bladecKVMCardVpdSerialNumber OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.6 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdMachineType OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.7 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdUuid OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.8 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdManufDate OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.9 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdPartNumber OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.10 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdFruSerial OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.11 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdMachineModel OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.12 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdManufacturingIDNumber OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.13 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdProductId OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.14 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdSubManufacturerId OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.15 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdClei OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.16 | OCTET STRING | read-only | mandatory |
| bladecKVMCardVpdHardwareRevisionString OBJECT-TYPE Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.17 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpdTable OBJECT-TYPE Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7 | not-accessible | mandatory | |
| bladeAndExpCardWwnGuidVpdEntry OBJECT-TYPE Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1 | not-accessible | mandatory | |
| bladeAndExpCardWwnGuidVpdIndex OBJECT-TYPE Blade or expansion card index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1 | INTEGER | read-only | mandatory |
| bladeAndExpCardWwnGuidVpdBayNumber OBJECT-TYPE Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpdName OBJECT-TYPE The name of the blade or expansion card. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpdBladeBayNumber OBJECT-TYPE For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpdType OBJECT-TYPE Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5 | INTEGER {notAvailable(0), wwn(1), guid(2), sas(3)} | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd1 OBJECT-TYPE Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd2 OBJECT-TYPE Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd3 OBJECT-TYPE Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd4 OBJECT-TYPE Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd5 OBJECT-TYPE Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd6 OBJECT-TYPE Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd7 OBJECT-TYPE Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12 | OCTET STRING | read-only | mandatory |
| bladeAndExpCardWwnGuidVpd8 OBJECT-TYPE Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdTable OBJECT-TYPE Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8 | not-accessible | mandatory | |
| bladeManagementCardVpdEntry OBJECT-TYPE Blade management card VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1 | not-accessible | mandatory | |
| bladeManagementCardVpdIndex OBJECT-TYPE Blade management card VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1 | INTEGER | read-only | mandatory |
| bladeManagementCardVpdBayNumber OBJECT-TYPE Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdManufacturingId OBJECT-TYPE Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdFruNumber OBJECT-TYPE Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdHardwareRevision OBJECT-TYPE Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5 | INTEGER | read-only | mandatory |
| bladeManagementCardVpdSerialNumber OBJECT-TYPE Blade management card VPD serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdMachineType OBJECT-TYPE Blade management card VPD machine type. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdUuid OBJECT-TYPE Blade management card VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdManufDate OBJECT-TYPE Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdPartNumber OBJECT-TYPE Blade management card VPD Part number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdFruSerial OBJECT-TYPE Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdMachineModel OBJECT-TYPE Blade management card VPD machine model. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdManufacturingIDNumber OBJECT-TYPE Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdProductId OBJECT-TYPE Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdSubManufacturerId OBJECT-TYPE Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdClei OBJECT-TYPE Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16 | OCTET STRING | read-only | mandatory |
| bladeManagementCardVpdHardwareRevisionString OBJECT-TYPE Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17 | OCTET STRING | read-only | mandatory |
| bladeFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.5 | |||
| bladeBiosVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1 | not-accessible | mandatory | |
| bladeBiosVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1 | not-accessible | mandatory | |
| bladeBiosVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1 | INTEGER | read-only | mandatory |
| bladeBiosVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeBiosVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeBiosVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bladeBiosVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5 | OCTET STRING | read-only | mandatory |
| bladeBiosVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6 | OCTET STRING | read-only | mandatory |
| bladeBiosVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7 | OCTET STRING | read-only | mandatory |
| bladeBiosVpdDate OBJECT-TYPE The date of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8 | OCTET STRING | read-only | mandatory |
| bladeBiosVpdLevelStatus OBJECT-TYPE The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9 | OCTET STRING | read-only | mandatory |
| bladeDiagsVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2 | not-accessible | mandatory | |
| bladeDiagsVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1 | not-accessible | mandatory | |
| bladeDiagsVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1 | INTEGER | read-only | mandatory |
| bladeDiagsVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeDiagsVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeDiagsVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bladeDiagsVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeDiagsVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6 | OCTET STRING | read-only | mandatory |
| bladeDiagsVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7 | OCTET STRING | read-only | mandatory |
| bladeDiagsVpdDate OBJECT-TYPE The date of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8 | OCTET STRING | read-only | mandatory |
| bladeDiagsVpdLevelStatus OBJECT-TYPE The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9 | OCTET STRING | read-only | mandatory |
| bladeSysMgmtProcVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3 | not-accessible | mandatory | |
| bladeSysMgmtProcVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1 | not-accessible | mandatory | |
| bladeSysMgmtProcVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1 | INTEGER | read-only | mandatory |
| bladeSysMgmtProcVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeSysMgmtProcVpdExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSysMgmtProcVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bladeSysMgmtProcVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5 | OCTET STRING | read-only | mandatory |
| bladeSysMgmtProcVpdBuildId OBJECT-TYPE The build ID for the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6 | OCTET STRING | read-only | mandatory |
| bladeSysMgmtProcVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7 | OCTET STRING | read-only | mandatory |
| bladeSysMgmtProcVpdLevelStatus OBJECT-TYPE The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8 | OCTET STRING | read-only | mandatory |
| bladecKVMVPDTable OBJECT-TYPE Table of blade firmware vital product data (VPD) information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4 | not-accessible | mandatory | |
| bladecKVMVPDEntry OBJECT-TYPE Blade firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1 | not-accessible | mandatory | |
| bladecKVMVpdIndex OBJECT-TYPE Blade firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.1 | INTEGER | read-only | mandatory |
| bladecKVMVpdId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladecKVMVpdExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladecKVMVpdPowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bladecKVMVpdName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.5 | OCTET STRING | read-only | mandatory |
| bladecKVMVpdRevision OBJECT-TYPE The revision of the blade firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.7 | OCTET STRING | read-only | mandatory |
| bladeFWBuildIDs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.5.5 | |||
| bladeFWBuildIDTable OBJECT-TYPE Table of Blade Firmware Build ID entries information. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1 | not-accessible | mandatory | |
| bladeFWBuildIDEntry OBJECT-TYPE Blade Firmware Build ID table entry | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1 | not-accessible | mandatory | |
| bladeFWBuildIDIndex OBJECT-TYPE The index number of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.1 | INTEGER | read-only | mandatory |
| bladeFWBuildMfg OBJECT-TYPE The Manufacturer property of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.2 | OCTET STRING | read-write | mandatory |
| bladeFWBuildMT OBJECT-TYPE The Machine Type property of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.3 | OCTET STRING | read-write | mandatory |
| bladeFWBuildFWType OBJECT-TYPE The Firmware Type property of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.4 | OCTET STRING | read-write | mandatory |
| bladeFWBuildID OBJECT-TYPE The Build ID property of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.5 | OCTET STRING | read-write | mandatory |
| bladeFWBuildRev OBJECT-TYPE The Build Revision property of one Build ID entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.6 | OCTET STRING | read-write | mandatory |
| createBladeFWBuildIDs OBJECT-TYPE Create one new Build ID List from current installed blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.2 | INTEGER {execute(1)} | write-only | mandatory |
| addBladeFWBuildID OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3 | |||
| addBladeMfg OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to set Manufacturer property. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.1 | OCTET STRING | read-write | mandatory |
| addBladeMt OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to set Machine Type property. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.2 | OCTET STRING | read-write | mandatory |
| addBladeFt OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to set Firmware Type property. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.3 | OCTET STRING | read-write | mandatory |
| addBladeBuildID OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to set Build ID property. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.4 | OCTET STRING | read-write | mandatory |
| addBladeBuildRev OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to set Build Revision property. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.5 | OCTET STRING | read-write | mandatory |
| exeBladeAdding OBJECT-TYPE Add one Build ID entry into the Build ID List. This is to perform the adding action. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.6 | INTEGER {execute(1)} | write-only | mandatory |
| rmBladeFWBuildID OBJECT-TYPE Remove one Build ID entry from the Build ID List. The index of the Build ID entry in the list is required. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.4 | INTEGER | write-only | mandatory |
| rmAllBladeFWBuildIDs OBJECT-TYPE Remove all Build ID entries from the Build ID List. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.5 | INTEGER {execute(1)} | write-only | mandatory |
| buildIDFileName OBJECT-TYPE File name of the Build ID list that will be used in import function. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.6 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| buildIDURIName OBJECT-TYPE Contains the fully qualified remote location of the build ID list. Use buildIDFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the build ID list resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the build ID list is /tmp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.7 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| buildIDtftpIP OBJECT-TYPE If importing/exporting via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.8 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| importBladeFWBuildIDs OBJECT-TYPE Import one Build ID List set by the buildIDFilename from a specific location set by buildIDServer. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.9 | INTEGER {execute(1)} | write-only | mandatory |
| exportBladeFWBuildIDs OBJECT-TYPE Export the current Build ID List from the active AMM to a specific location set by buildIDServer. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.10 | INTEGER {execute(1)} | write-only | mandatory |
| statusBladeFWBuildIDs OBJECT-TYPE Gives the status message from the last import or export operation. | 1.3.6.1.4.1.2.3.51.2.2.21.5.5.11 | OCTET STRING | read-only | mandatory |
| smHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.6 | |||
| smHardwareVpdTable OBJECT-TYPE Table of the switch module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1 | not-accessible | mandatory | |
| smHardwareVpdEntry OBJECT-TYPE Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1 | not-accessible | mandatory | |
| smHardwareVpdIndex OBJECT-TYPE Switch module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1 | INTEGER | read-only | mandatory |
| smHardwareVpdBayNumber OBJECT-TYPE Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2 | OCTET STRING | read-only | mandatory |
| smHardwareVpdManufacturingId OBJECT-TYPE Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3 | OCTET STRING | read-only | mandatory |
| smHardwareVpdFruNumber OBJECT-TYPE Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4 | OCTET STRING | read-only | mandatory |
| smHardwareVpdHardwareRevision OBJECT-TYPE Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5 | INTEGER | read-only | mandatory |
| smHardwareVpdUuid OBJECT-TYPE Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8 | OCTET STRING | read-only | mandatory |
| smHardwareVpdManufDate OBJECT-TYPE Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9 | OCTET STRING | read-only | mandatory |
| smHardwareVpdPartNumber OBJECT-TYPE Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10 | OCTET STRING | read-only | mandatory |
| smHardwareVpdFruSerial OBJECT-TYPE Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11 | OCTET STRING | read-only | mandatory |
| smHardwareVpdManufacturingIDNumber OBJECT-TYPE Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12 | OCTET STRING | read-only | mandatory |
| smHardwareVpdProductId OBJECT-TYPE Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13 | OCTET STRING | read-only | mandatory |
| smHardwareVpdSubManufacturerId OBJECT-TYPE Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14 | OCTET STRING | read-only | mandatory |
| smHardwareVpdClei OBJECT-TYPE Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15 | OCTET STRING | read-only | mandatory |
| smHardwareVpdWwnGuid OBJECT-TYPE Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16 | OCTET STRING | read-only | mandatory |
| smHardwareVpdWwnGuidType OBJECT-TYPE The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17 | OCTET STRING | read-only | mandatory |
| smHardwareVpdWidth OBJECT-TYPE The width of the switch module hardware. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18 | INTEGER | read-only | mandatory |
| smHardwareVpdHardwareRevisionString OBJECT-TYPE Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdTable OBJECT-TYPE Table of the switch interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2 | not-accessible | mandatory | |
| smInpHardwareVpdEntry OBJECT-TYPE Switch Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1 | not-accessible | mandatory | |
| smInpHardwareVpdIndex OBJECT-TYPE Switch Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.1 | INTEGER | read-only | mandatory |
| smInpHardwareVpdBayNumber OBJECT-TYPE Switch Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.2 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdManufacturingId OBJECT-TYPE Switch Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.3 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdFruNumber OBJECT-TYPE Switch Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.4 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdHardwareRevision OBJECT-TYPE Switch Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.5 | INTEGER | read-only | mandatory |
| smInpHardwareVpdUuid OBJECT-TYPE Switch Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.8 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdManufDate OBJECT-TYPE Switch Interposer hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.9 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdPartNumber OBJECT-TYPE Switch Interposer hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.10 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdFruSerial OBJECT-TYPE Switch Interposer module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.11 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdManufacturingIDNumber OBJECT-TYPE Switch Interposer module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.12 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdProductId OBJECT-TYPE Switch Interposer module hardware VPD product ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.13 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdSubManufacturerId OBJECT-TYPE Switch Interposer module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.14 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdClei OBJECT-TYPE Switch Interposer module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.15 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdWwnGuid OBJECT-TYPE Switch Interposer module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.16 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdWwnGuidType OBJECT-TYPE The Switch Interposer WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.17 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdWidth OBJECT-TYPE The width of the switch Interposer module hardware. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.18 | INTEGER | read-only | mandatory |
| smInpHardwareVpdName OBJECT-TYPE The Switch Interposer Name. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.19 | OCTET STRING | read-only | mandatory |
| smInpHardwareVpdHardwareRevisionString OBJECT-TYPE Switch Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.20 | OCTET STRING | read-only | mandatory |
| smFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.7 | |||
| smMainAppVpdTable OBJECT-TYPE Switch module main application VPD information table. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1 | not-accessible | mandatory | |
| smMainAppVpdEntry OBJECT-TYPE Switch module main application VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1 | not-accessible | mandatory | |
| smMainAppVpdIndex OBJECT-TYPE Switch module main application VPD entry index. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1 | INTEGER | read-only | mandatory |
| smMainAppVpdId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smMainAppVpdExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smMainAppVpdSwitchType OBJECT-TYPE Indicates the type of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4 | INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)} | read-only | mandatory |
| smMainApp1VpdBuildId OBJECT-TYPE Switch module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5 | OCTET STRING | read-only | mandatory |
| smMainApp1VpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6 | OCTET STRING | read-only | mandatory |
| smMainApp1VpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7 | OCTET STRING | read-only | mandatory |
| smMainApp2VpdBuildId OBJECT-TYPE Switch module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8 | OCTET STRING | read-only | mandatory |
| smMainApp2VpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9 | OCTET STRING | read-only | mandatory |
| smMainApp2VpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10 | OCTET STRING | read-only | mandatory |
| smMainApp3VpdBuildId OBJECT-TYPE I/O Module firmware build id. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11 | OCTET STRING | read-only | mandatory |
| smMainApp3VpdBuildDate OBJECT-TYPE I/O Module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12 | OCTET STRING | read-only | mandatory |
| smMainApp3VpdRevisionNumber OBJECT-TYPE I/O Module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13 | OCTET STRING | read-only | mandatory |
| smMainAppVpdSwitchSubType OBJECT-TYPE Indicates the subtype of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20 | INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)} | read-only | mandatory |
| smBootRomVpdTable OBJECT-TYPE Switch module boot ROM VPD information table. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2 | not-accessible | mandatory | |
| smBootRomVpdEntry OBJECT-TYPE Switch module boot ROM VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1 | not-accessible | mandatory | |
| smBootRomVpdIndex OBJECT-TYPE Switch module boot ROM VPD entry index. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1 | INTEGER | read-only | mandatory |
| smBootRomVpdId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smBootRomVpdExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smBootRomVpdSwitchType OBJECT-TYPE Indicates the type of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4 | INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)} | read-only | mandatory |
| smBootRomVpdBuildId OBJECT-TYPE Switch module firmware build ID. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5 | OCTET STRING | read-only | mandatory |
| smBootRomVpdBuildDate OBJECT-TYPE Switch module firmware build date. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6 | OCTET STRING | read-only | mandatory |
| smBootRomVpdRevisionNumber OBJECT-TYPE Switch module firmware revision number. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7 | OCTET STRING | read-only | mandatory |
| smBootRomVpdSwitchSubType OBJECT-TYPE Indicates the subtype of switch module installed. | 1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8 | INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)} | read-only | mandatory |
| pmHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.8 | |||
| pmHardwareVpdTable OBJECT-TYPE Table of the power module hardware components. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1 | not-accessible | mandatory | |
| pmHardwareVpdEntry OBJECT-TYPE Power module hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1 | not-accessible | mandatory | |
| pmHardwareVpdIndex OBJECT-TYPE Power module hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1 | INTEGER | read-only | mandatory |
| pmHardwareVpdBayNumber OBJECT-TYPE Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdManufacturingId OBJECT-TYPE Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdFruNumber OBJECT-TYPE Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdHardwareRevision OBJECT-TYPE Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5 | INTEGER | read-only | mandatory |
| pmHardwareVpdUuid OBJECT-TYPE Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdManufDate OBJECT-TYPE Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdPartNumber OBJECT-TYPE Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdFruSerial OBJECT-TYPE Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdManufacturingIDNumber OBJECT-TYPE Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdProductId OBJECT-TYPE Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdSubManufacturerId OBJECT-TYPE Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdClei OBJECT-TYPE Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15 | OCTET STRING | read-only | mandatory |
| pmHardwareVpdHardwareRevisionString OBJECT-TYPE Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16 | OCTET STRING | read-only | mandatory |
| mtHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.9 | |||
| mtHardwareVpdManufacturingId OBJECT-TYPE Media tray 1 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.3 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdFruNumber OBJECT-TYPE Media tray 1 hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.4 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdHardwareRevision OBJECT-TYPE Media tray 1 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.9.5 | INTEGER | read-only | mandatory |
| mtHardwareVpdUuid OBJECT-TYPE Media tray 1 hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.8 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdManufacturingIDNumber OBJECT-TYPE Media tray 1 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.9 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdProductId OBJECT-TYPE Media tray 1 hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.10 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdSubManufacturerId OBJECT-TYPE Media tray 1 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.11 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdClei OBJECT-TYPE Media tray 1 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.12 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdCF1Capacity OBJECT-TYPE Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.13 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdCF2Capacity OBJECT-TYPE Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.9.14 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdBBU1 OBJECT-TYPE Indicates the presence of Battery Backup Unit 1. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.9.15 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mtHardwareVpdBBU2 OBJECT-TYPE Indicates the presence of Battery Backup Unit 2. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.9.16 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mtHardwareVpdHardwareRevisionString OBJECT-TYPE Media tray 1 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.9.17 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdManufDate OBJECT-TYPE Media tray 1 hardware VPD Manufacture Date. | 1.3.6.1.4.1.2.3.51.2.2.21.9.18 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdPartNumber OBJECT-TYPE Media tray 1 hardware VPD Part Number. | 1.3.6.1.4.1.2.3.51.2.2.21.9.19 | OCTET STRING | read-only | mandatory |
| mtHardwareVpdFruSerial OBJECT-TYPE Media tray 1 hardware VPD FRU Serial. | 1.3.6.1.4.1.2.3.51.2.2.21.9.20 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.10 | |||
| mt2HardwareVpdManufacturingId OBJECT-TYPE Media tray 2 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.3 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdFruNumber OBJECT-TYPE Media tray 2 hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.4 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdHardwareRevision OBJECT-TYPE Media tray 2 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.10.5 | INTEGER | read-only | mandatory |
| mt2HardwareVpdUuid OBJECT-TYPE Media tray 2 hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.8 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdManufacturingIDNumber OBJECT-TYPE Media tray 2 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.9 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdProductId OBJECT-TYPE Media tray 2 hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.10 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdSubManufacturerId OBJECT-TYPE Media tray 2 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.11 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdClei OBJECT-TYPE Media tray 2 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.12 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdCF1Capacity OBJECT-TYPE Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.13 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdCF2Capacity OBJECT-TYPE Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.10.14 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdHardwareRevisionString OBJECT-TYPE Media tray 2 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.10.17 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdManufDate OBJECT-TYPE Media tray 2 hardware VPD Manufacture Date. | 1.3.6.1.4.1.2.3.51.2.2.21.10.18 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdPartNumber OBJECT-TYPE Media tray 2 hardware VPD Part Number. | 1.3.6.1.4.1.2.3.51.2.2.21.10.19 | OCTET STRING | read-only | mandatory |
| mt2HardwareVpdFruSerial OBJECT-TYPE Media tray 2 hardware VPD FRU Serial. | 1.3.6.1.4.1.2.3.51.2.2.21.10.20 | OCTET STRING | read-only | mandatory |
| blowerFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.12 | |||
| blowerControllerVPDTable OBJECT-TYPE Table of blower controller firmware vital product data (VPD) information. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1 | not-accessible | mandatory | |
| blowerControllerVPDEntry OBJECT-TYPE Blower controller firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1 | not-accessible | mandatory | |
| blowerControllerVpdIndex OBJECT-TYPE Blower controller firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1 | INTEGER | read-only | mandatory |
| blowerControllerVpdId OBJECT-TYPE The numeric blower ID. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2 | INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)} | read-only | mandatory |
| blowerControllerVpdExists OBJECT-TYPE Indicates whether the blower specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| blowerControllerVpdRevision OBJECT-TYPE The revision of the blower controller firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.13 | |||
| blowerHardwareVpdTable OBJECT-TYPE Table of the blower hardware components. For consistent results, view as a table and not as individual entries. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1 | not-accessible | mandatory | |
| blowerHardwareVpdEntry OBJECT-TYPE Blower hardware VPD entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1 | not-accessible | mandatory | |
| blowerHardwareVpdIndex OBJECT-TYPE Blower hardware VPD index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1 | INTEGER | read-only | mandatory |
| blowerHardwareVpdBayNumber OBJECT-TYPE Blower hardware VPD Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdManufacturingId OBJECT-TYPE Blower hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdFruNumber OBJECT-TYPE Blower hardware VPD FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdHardwareRevision OBJECT-TYPE Blower hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5 | INTEGER | read-only | mandatory |
| blowerHardwareVpdUuid OBJECT-TYPE Blower hardware VPD UUID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdManufDate OBJECT-TYPE Blower hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdPartNumber OBJECT-TYPE Blower hardware VPD Part Number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdFruSerial OBJECT-TYPE Blower hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdManufacturingIDNumber OBJECT-TYPE Blower hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdProductId OBJECT-TYPE Blower hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdSubManufacturerId OBJECT-TYPE Blower hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdClei OBJECT-TYPE Blower hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15 | OCTET STRING | read-only | mandatory |
| blowerHardwareVpdHardwareRevisionString OBJECT-TYPE Blower hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16 | OCTET STRING | read-only | mandatory |
| fanPackFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.14 | |||
| fanPackControllerVPDTable OBJECT-TYPE Table of fan pack controller firmware vital product data (VPD) information. NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1 | not-accessible | mandatory | |
| fanPackControllerVPDEntry OBJECT-TYPE Fan Pack controller firmware VPD table entry | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1 | not-accessible | mandatory | |
| fanPackControllerVpdIndex OBJECT-TYPE Fan Pack controller firmware VPD table index. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1 | INTEGER | read-only | mandatory |
| fanPackControllerVpdId OBJECT-TYPE The numeric fan pack ID. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2 | INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4)} | read-only | mandatory |
| fanPackControllerVpdExists OBJECT-TYPE Indicates whether the fan pack specified exists or not. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| fanPackControllerVpdRevision OBJECT-TYPE The revision of the fan pack controller firmware. | 1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7 | OCTET STRING | read-only | mandatory |
| tapHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.15 | |||
| tapHardwareVpdManufacturingId OBJECT-TYPE Telco Alarm Panel hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.3 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdFruNumber OBJECT-TYPE Telco Alarm Panel hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.4 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdHardwareRevision OBJECT-TYPE Telco Alarm Panel hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.15.5 | INTEGER | read-only | mandatory |
| tapHardwareVpdUuid OBJECT-TYPE Telco Alarm Panel hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.8 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdManufDate OBJECT-TYPE Telco Alarm Panel hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.9 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdPartNumber OBJECT-TYPE Telco Alarm Panel hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.10 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdFruSerial OBJECT-TYPE Telco Alarm Panel hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.15.11 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdManufacturingIDNumber OBJECT-TYPE Telco Alarm Panel hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.15.12 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdProductId OBJECT-TYPE Telco Alarm Panel hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.15.13 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdSubManufacturerId OBJECT-TYPE Telco Alarm Panel hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.15.14 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdClei OBJECT-TYPE Telco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.15.15 | OCTET STRING | read-only | mandatory |
| tapHardwareVpdHardwareRevisionString OBJECT-TYPE Telco Alarm Panel hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.15.16 | OCTET STRING | read-only | mandatory |
| ncHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.16 | |||
| ncHardwareVpdTable OBJECT-TYPE Table of the Network Clock hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1 | not-accessible | deprecated | |
| ncHardwareVpdEntry OBJECT-TYPE Network Clock hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1 | not-accessible | deprecated | |
| ncHardwareVpdIndex OBJECT-TYPE Network Clock hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.1 | INTEGER | read-only | deprecated |
| ncHardwareVpdBayNumber OBJECT-TYPE Network Clock hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.2 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdManufacturingId OBJECT-TYPE Network Clock hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.3 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdFruNumber OBJECT-TYPE Network Clock hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.4 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdHardwareRevision OBJECT-TYPE Network Clock hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.5 | INTEGER | read-only | deprecated |
| ncHardwareVpdUuid OBJECT-TYPE Network Clock hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.8 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdManufDate OBJECT-TYPE Network Clock hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.9 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdPartNumber OBJECT-TYPE Network Clock hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.10 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdFruSerial OBJECT-TYPE Network Clock hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.11 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdManufacturingIDNumber OBJECT-TYPE Network Clock hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.12 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdProductId OBJECT-TYPE Network Clock hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.13 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdSubManufacturerId OBJECT-TYPE Network Clock hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.14 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdClei OBJECT-TYPE Network Clock hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.15 | OCTET STRING | read-only | deprecated |
| ncHardwareVpdHardwareRevisionString OBJECT-TYPE Network Clock hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.16 | OCTET STRING | read-only | deprecated |
| mxHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.17 | |||
| mxHardwareVpdTable OBJECT-TYPE Table of the Multiplexer Expansion Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1 | not-accessible | mandatory | |
| mxHardwareVpdEntry OBJECT-TYPE Multiplexer Expansion Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1 | not-accessible | mandatory | |
| mxHardwareVpdIndex OBJECT-TYPE Multiplexer Expansion Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.1 | INTEGER | read-only | mandatory |
| mxHardwareVpdBayNumber OBJECT-TYPE Multiplexer Expansion Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.2 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdManufacturingId OBJECT-TYPE Multiplexer Expansion Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.3 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdFruNumber OBJECT-TYPE Multiplexer Expansion Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.4 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdHardwareRevision OBJECT-TYPE Multiplexer Expansion Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.5 | INTEGER | read-only | mandatory |
| mxHardwareVpdUuid OBJECT-TYPE Multiplexer Expansion Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.8 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdManufDate OBJECT-TYPE Multiplexer Expansion Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.9 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdPartNumber OBJECT-TYPE Multiplexer Expansion Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.10 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdFruSerial OBJECT-TYPE Multiplexer Expansion Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.11 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdManufacturingIDNumber OBJECT-TYPE Multiplexer Expansion Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.12 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdProductId OBJECT-TYPE Multiplexer Expansion Module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.13 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdSubManufacturerId OBJECT-TYPE Multiplexer Expansion Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.14 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdClei OBJECT-TYPE Multiplexer Expansion Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.15 | OCTET STRING | read-only | mandatory |
| mxHardwareVpdHardwareRevisionString OBJECT-TYPE Multiplexer Expansion Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.16 | OCTET STRING | read-only | mandatory |
| stmHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.18 | |||
| stmHardwareVpdTable OBJECT-TYPE Table of the Storage Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1 | not-accessible | mandatory | |
| stmHardwareVpdEntry OBJECT-TYPE Storage Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1 | not-accessible | mandatory | |
| stmHardwareVpdIndex OBJECT-TYPE Storage Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.1 | INTEGER | read-only | mandatory |
| stmHardwareVpdBayNumber OBJECT-TYPE Storage Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.2 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdManufacturingId OBJECT-TYPE Storage Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.3 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdFruNumber OBJECT-TYPE Storage Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.4 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdHardwareRevision OBJECT-TYPE Storage Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.5 | INTEGER | read-only | mandatory |
| stmHardwareVpdUuid OBJECT-TYPE Storage Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.8 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdManufDate OBJECT-TYPE Storage Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.9 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdPartNumber OBJECT-TYPE Storage Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.10 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdFruSerial OBJECT-TYPE Storage Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.11 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdManufacturingIDNumber OBJECT-TYPE Storage Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.12 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdProductId OBJECT-TYPE Storage Module hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.13 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdSubManufacturerId OBJECT-TYPE Storage Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.14 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdClei OBJECT-TYPE Storage Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.15 | OCTET STRING | read-only | mandatory |
| stmHardwareVpdHardwareRevisionString OBJECT-TYPE Storage Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used. | 1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.16 | OCTET STRING | read-only | mandatory |
| stmFirmwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.19 | |||
| stmFirmwareVpdTable OBJECT-TYPE Table of the Storage Module firmware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1 | not-accessible | mandatory | |
| stmFirmwareVpdEntry OBJECT-TYPE Storage Module firmware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1 | not-accessible | mandatory | |
| stmFirmwareVpdIndex OBJECT-TYPE Storage Module firmware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.1 | INTEGER | read-only | mandatory |
| stmFirmwareVpdType OBJECT-TYPE Storage Module firmware VPD type. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.2 | OCTET STRING | read-only | mandatory |
| stmFirmwareVpdBuildId OBJECT-TYPE Storage Module firmware VPD build ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.3 | OCTET STRING | read-only | mandatory |
| stmFirmwareVpdReleaseDate OBJECT-TYPE Storage Module firmware VPD release date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.4 | OCTET STRING | read-only | mandatory |
| stmFirmwareVpdRevision OBJECT-TYPE Storage Module firmware VPD revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.5 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpd OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.21 | |||
| bbuHardwareVpdTable OBJECT-TYPE Table of the Battery Backup Unit hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1 | not-accessible | mandatory | |
| bbuHardwareVpdEntry OBJECT-TYPE Battery Backup Unit hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1 | not-accessible | mandatory | |
| bbuHardwareVpdIndex OBJECT-TYPE Battery Backup Unit hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.1 | INTEGER | read-only | mandatory |
| bbuHardwareVpdBayNumber OBJECT-TYPE Battery Backup Unit hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.2 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdManufacturingId OBJECT-TYPE Battery Backup Unit hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.3 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdFruNumber OBJECT-TYPE Battery Backup Unit hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.4 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdHardwareRevision OBJECT-TYPE Battery Backup Unit hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.5 | INTEGER | read-only | mandatory |
| bbuHardwareVpdUuid OBJECT-TYPE Battery Backup Unit hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.8 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdManufDate OBJECT-TYPE Battery Backup Unit hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.9 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdPartNumber OBJECT-TYPE Battery Backup Unit hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.10 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdFruSerial OBJECT-TYPE Battery Backup Unit hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.11 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdManufacturingIDNumber OBJECT-TYPE Battery Backup Unit hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.12 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdProductId OBJECT-TYPE Battery Backup Unit hardware VPD product ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.13 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdSubManufacturerId OBJECT-TYPE Battery Backup Unit hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.14 | OCTET STRING | read-only | mandatory |
| bbuHardwareVpdClei OBJECT-TYPE Battery Backup Unit hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.15 | OCTET STRING | read-only | mandatory |
| inventoryManagementActivityVpdTable OBJECT-TYPE Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22 | not-accessible | mandatory | |
| inventoryManagementActivityVpdEntry OBJECT-TYPE System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1 | not-accessible | mandatory | |
| componentLevelActivityVpdIndex OBJECT-TYPE System component level VPD activity log index. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.1 | INTEGER | read-only | mandatory |
| componentLevelActivityVpdFruNumber OBJECT-TYPE System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.2 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdSerialNumber OBJECT-TYPE System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.3 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdManufacturingId OBJECT-TYPE System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.4 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdBayNumber OBJECT-TYPE System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.5 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdAction OBJECT-TYPE System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.9 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdTimestamp OBJECT-TYPE System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.10 | OCTET STRING | read-only | mandatory |
| componentLevelActivityVpdModuleName OBJECT-TYPE The module name which this row is associated with. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.2.21.22.1.12 | OCTET STRING | read-only | mandatory |
| reloadVpdData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.21.23 | |||
| reloadAllVpdData OBJECT-TYPE Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.1 | INTEGER {execute(1)} | read-write | mandatory |
| reloadFwVpdData OBJECT-TYPE Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.2 | INTEGER {execute(1)} | read-write | mandatory |
| reloadHwVpdData OBJECT-TYPE Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.3 | INTEGER {execute(1)} | read-write | mandatory |
| reloadMACAddress OBJECT-TYPE Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.4 | INTEGER {execute(1)} | read-write | mandatory |
| reloadWwnGuidVpdData OBJECT-TYPE Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.2.21.23.5 | INTEGER {execute(1)} | read-write | mandatory |
| airFilter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.22 | |||
| passiveAirFilter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.22.1 | |||
| passiveAirFilterStatus OBJECT-TYPE Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. The reset command is only applicable in BladeCenter Telco Refresh and it will restart the Fouled Filter Detection settings. NOTE: This MIB object is only applicable for BladeCenter S, BladeCenter E Refresh, and BladeCenter Telco Refresh. | 1.3.6.1.4.1.2.3.51.2.2.22.1.1 | INTEGER {disabled(0), enabled(1), reset(2)} | read-write | mandatory |
| passiveAirFilterMonthFreq OBJECT-TYPE The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only. | 1.3.6.1.4.1.2.3.51.2.2.22.1.2 | INTEGER {oneMonth(1), threeMonths(3), sixMonths(6)} | read-write | mandatory |
| passiveAirFilterReplaceDate OBJECT-TYPE The scheduled replacement date of the air filter. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only. | 1.3.6.1.4.1.2.3.51.2.2.22.1.3 | OCTET STRING (SIZE(0..30)) | read-only | mandatory |
| componentInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23 | |||
| componentInventory OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23.1 | |||
| componentInventoryTable OBJECT-TYPE Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1 | not-accessible | mandatory | |
| componentInventoryEntry OBJECT-TYPE Component inventory information. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1 | not-accessible | mandatory | |
| componentInventoryTopologyPath OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentInventoryInstance OBJECT-TYPE The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2 | INTEGER | read-only | mandatory |
| componentInventoryDescription OBJECT-TYPE A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3 | OCTET STRING | read-only | mandatory |
| componentInventoryMachineTypeModel OBJECT-TYPE The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4 | OCTET STRING | read-only | mandatory |
| componentInventoryMachineSerial OBJECT-TYPE The machine serial number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5 | OCTET STRING | read-only | mandatory |
| componentInventoryAssetID OBJECT-TYPE The asset identifier of this component, typically set by some other authority than the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6 | OCTET STRING | read-only | mandatory |
| componentInventoryPartNumber OBJECT-TYPE The part number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7 | OCTET STRING | read-only | mandatory |
| componentInventoryFRUNumber OBJECT-TYPE The Field Replaceable Unit (FRU) number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8 | OCTET STRING | read-only | mandatory |
| componentInventoryFRUSerialNumber OBJECT-TYPE The Field Replaceable Unit (FRU) serial number of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9 | OCTET STRING | read-only | mandatory |
| componentInventoryManufactureID OBJECT-TYPE The text description of the manufacturer of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10 | OCTET STRING | read-only | mandatory |
| componentInventoryHardwareRevision OBJECT-TYPE The hardware revision number of the this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11 | OCTET STRING | read-only | mandatory |
| componentInventoryManufactureDate OBJECT-TYPE The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12 | OCTET STRING | read-only | mandatory |
| componentInventoryUUID OBJECT-TYPE The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13 | OCTET STRING | read-only | mandatory |
| componentInventoryProductID OBJECT-TYPE The product identifier of the component assigned by the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14 | OCTET STRING | read-only | mandatory |
| componentInventorySubManufactureID OBJECT-TYPE The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15 | OCTET STRING | read-only | mandatory |
| componentInventoryCLEI OBJECT-TYPE The Common Language Equipment Identifier (CLEI) of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16 | OCTET STRING | read-only | mandatory |
| componentInventoryAssetTag OBJECT-TYPE The asset tag of this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17 | OCTET STRING | read-only | mandatory |
| componentInventorySpeed OBJECT-TYPE A speed designation for the component, for example, processor speed. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18 | OCTET STRING | read-only | mandatory |
| componentInventoryIdentifier OBJECT-TYPE A unique identifier assigned by the manufacturer to the component, for example, a processor ID. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19 | OCTET STRING | read-only | mandatory |
| componentInventorySize OBJECT-TYPE A size designation for the component, for example, a memory DIMM size or hard drive capacity. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20 | INTEGER | read-only | mandatory |
| componentInventoryMemoryType OBJECT-TYPE The architecture specification of a memory device. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21 | INTEGER {fpmdram(1), edo(2), edodram(3), sdram(4), multiplexedram(5), ddrsgram(6), ddrsdram(7), ddr2sdrm(8), ddr3sdram(9)} | read-only | mandatory |
| componentInventoryProductName OBJECT-TYPE The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22 | OCTET STRING | read-only | mandatory |
| componentInventoryProductVersion OBJECT-TYPE The product version assigned by the manufacturer for this component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorType OBJECT-TYPE The type designation for processor components. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24 | INTEGER {other(1), unknown(2), central(3), math(4), dsp(5), video(6)} | read-only | mandatory |
| componentInventoryProcessorFamily OBJECT-TYPE The family designation for processor components. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorCores OBJECT-TYPE The number of cores present on a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorThreads OBJECT-TYPE The number of threads present on a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL1DCache OBJECT-TYPE The level 1 data cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL1ICache OBJECT-TYPE The level 1 instruction cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL2Cache OBJECT-TYPE The level 2 cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorL3Cache OBJECT-TYPE The level 3 cache size of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorVoltage OBJECT-TYPE The voltage rating for a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorExtClock OBJECT-TYPE The external clock speed of a processor component. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33 | OCTET STRING | read-only | mandatory |
| componentInventoryProcessorDataWidth OBJECT-TYPE The maximum data bus width capability of a processor component, expressed typically in bits. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34 | OCTET STRING | read-only | mandatory |
| componentInventoryManufactureIDNum OBJECT-TYPE The identification number assigned for the component by the manufacturer. | 1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35 | INTEGER | read-only | mandatory |
| componentFirmware OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.2.23.2 | |||
| componentFirmwareTable OBJECT-TYPE Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1 | not-accessible | mandatory | |
| componentFirmwareEntry OBJECT-TYPE Component firmware information. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1 | not-accessible | mandatory | |
| componentFirmwareTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentFirmwareIndex OBJECT-TYPE Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2 | INTEGER | read-only | mandatory |
| componentFirmwareComponentInstance OBJECT-TYPE The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3 | INTEGER | read-only | mandatory |
| componentFirmwareComponentDescription OBJECT-TYPE A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4 | OCTET STRING | read-only | mandatory |
| componentFirmwareType OBJECT-TYPE A text description of the type of firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5 | OCTET STRING | read-only | mandatory |
| componentFirmwareBuildID OBJECT-TYPE A text description of the build identifier for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6 | OCTET STRING | read-only | mandatory |
| componentFirmwareReleaseDate OBJECT-TYPE A text description of the release date for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7 | OCTET STRING | read-only | mandatory |
| componentFirmwareFilename OBJECT-TYPE A text description of the filename of this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8 | OCTET STRING | read-only | mandatory |
| componentFirmwareRevision OBJECT-TYPE A text description of the revision level of this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9 | OCTET STRING | read-only | mandatory |
| componentFirmwareRevisionMajor OBJECT-TYPE A numeric identifier of the revision major number for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10 | INTEGER | read-only | mandatory |
| componentFirmwareRevisionMinor OBJECT-TYPE A numeric identifier of the revision minor number for this firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11 | INTEGER | read-only | mandatory |
| componentFirmwareLevelStatus OBJECT-TYPE The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID). | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingBuildID OBJECT-TYPE A text description of the build identifier for this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingReleaseDate OBJECT-TYPE A text description of the release date for this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14 | OCTET STRING | read-only | mandatory |
| componentFirmwarePendingRevision OBJECT-TYPE A text description of the revision level of this pending firmware load. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15 | OCTET STRING | read-only | mandatory |
| componentFirmwareTypeID OBJECT-TYPE Indicates the type of firmware load with a numeric identifier. | 1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20 | INTEGER {bladeFwBios(1), bladeDiagnostics(2), bladeSysMgmtProcessor(3), bladeFpga(4), bladecKVM(5), switchModuleMainAppl1(41), switchModuleMainAppl2(42), switchModuleBootROM(43), mgmtModuleMainAppl(61), mgmtModuleMainApplPendingRestart(62), fanController(81), unknown(255)} | read-only | mandatory |
| componentInventoryReady OBJECT-TYPE When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades have completed initialization and the inventory information has been provided to the AMM. Note that due to blades that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period. A more granular, per-blade status is available via the bladeSystemStatusTable | 1.3.6.1.4.1.2.3.51.2.2.23.3 | INTEGER {notReady(0), ready(1)} | read-only | mandatory |
| componentDriveTable OBJECT-TYPE Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table. | 1.3.6.1.4.1.2.3.51.2.2.23.10 | not-accessible | mandatory | |
| componentDriveEntry OBJECT-TYPE Component drive information. | 1.3.6.1.4.1.2.3.51.2.2.23.10.1 | not-accessible | mandatory | |
| componentDriveTopologyPath OBJECT-TYPE The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentDriveDescription OBJECT-TYPE A short text string describing the particular drive on the component. | 1.3.6.1.4.1.2.3.51.2.2.23.10.1.2 | OCTET STRING | read-only | mandatory |
| errorLogs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.3 | |||
| eventLog OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.3.4 | |||
| readEventLogTable OBJECT-TYPE Table of event log entry information. | 1.3.6.1.4.1.2.3.51.2.3.4.2 | not-accessible | mandatory | |
| readEventLogEntry OBJECT-TYPE Event log table entry | 1.3.6.1.4.1.2.3.51.2.3.4.2.1 | not-accessible | mandatory | |
| readEventLogIndex OBJECT-TYPE The event log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.1 | INTEGER | read-only | mandatory |
| readEventLogString OBJECT-TYPE A string of data detailing an event. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.2.1.2 | OCTET STRING | read-only | mandatory |
| clearEventLog OBJECT-TYPE Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.3 | INTEGER {execute(1)} | read-write | mandatory |
| monitorLogStateEvents OBJECT-TYPE If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out. | 1.3.6.1.4.1.2.3.51.2.3.4.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| readEnhancedEventLogTable OBJECT-TYPE Table of enhanced event log entry information. | 1.3.6.1.4.1.2.3.51.2.3.4.6 | not-accessible | mandatory | |
| readEnhancedEventLogEntry OBJECT-TYPE Enhaced Event log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1 | not-accessible | mandatory | |
| readEnhancedEventLogNumber OBJECT-TYPE The event log number for the enhanced event log. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.1 | INTEGER | read-only | mandatory |
| readEnhancedEventLogAttribute OBJECT-TYPE A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.2 | OCTET STRING | read-only | mandatory |
| readEnhancedEventLogMessage OBJECT-TYPE A string of data detailing an event log message. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.6.1.3 | OCTET STRING | read-only | mandatory |
| readAuditLogTable OBJECT-TYPE Table of audit log entry information. Audit log includes the logs whose source is 'Audit' | 1.3.6.1.4.1.2.3.51.2.3.4.10 | not-accessible | mandatory | |
| readAuditLogEntry OBJECT-TYPE Audit log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1 | not-accessible | mandatory | |
| readAuditLogNumber OBJECT-TYPE The audit log number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.1 | INTEGER | read-only | mandatory |
| readAuditLogAttribute OBJECT-TYPE A string of data detailing an audit eventlog's attribute. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.2 | OCTET STRING | read-only | mandatory |
| readAuditLogMessage OBJECT-TYPE A string of data detailing an audit event log message. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.10.1.3 | OCTET STRING | read-only | mandatory |
| clearAuditLog OBJECT-TYPE Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.11 | INTEGER {execute(1)} | read-write | mandatory |
| readSystemLogTable OBJECT-TYPE Table of system log entry information. System log includes the logs whose source is other than 'Audit' | 1.3.6.1.4.1.2.3.51.2.3.4.12 | not-accessible | mandatory | |
| readSystemLogEntry OBJECT-TYPE System log table entry, new entries could be added for new items. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1 | not-accessible | mandatory | |
| readSystemLogNumber OBJECT-TYPE The system log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.1 | INTEGER | read-only | mandatory |
| readSystemLogAttribute OBJECT-TYPE A string of data detailing an system event log's attribute. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.2 | OCTET STRING | read-only | mandatory |
| readSystemLogMessage OBJECT-TYPE A string of data detailing an system event log message. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.3.4.12.1.3 | OCTET STRING | read-only | mandatory |
| clearSystemLog OBJECT-TYPE Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.3.4.13 | INTEGER {execute(1)} | read-write | mandatory |
| configureSP OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4 | |||
| remoteAccessConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1 | |||
| generalRemoteCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1 | |||
| remoteAlertRetryDelay OBJECT-TYPE Number in seconds to delay between retries if sending a remote alert is unsuccessful. | 1.3.6.1.4.1.2.3.51.2.4.1.1.3 | INTEGER {noDelay(0), oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)} | read-write | mandatory |
| remoteAlertRetryCount OBJECT-TYPE Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted. | 1.3.6.1.4.1.2.3.51.2.4.1.1.4 | INTEGER {noretry(0), retry1(1), retry2(2), retry3(3), retry4(4), retry5(5), retry6(6), retry7(7), retry8(8)} | read-write | mandatory |
| remoteAlertEntryDelay OBJECT-TYPE Number in seconds to delay between entries if sending a remote alert is unsuccessful. NOTE: This object is no longer supported. However, for compatibilities sake, a value of (255) is returned when read. Also, write access has been removed. | 1.3.6.1.4.1.2.3.51.2.4.1.1.5 | INTEGER {noDelay(0), oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)} | read-only | deprecated |
| remoteAccessTamperDelay OBJECT-TYPE This value is no longer supported and has been replaced by 'lockoutPeriod'. | 1.3.6.1.4.1.2.3.51.2.4.1.1.6 | INTEGER {nowait(0), oneMinute(1), twoMinutes(2), threeMinutes(3), fourMinutes(4), fiveMinutes(5), sixMinutes(6), sevenMinutes(7), tenMinutes(10), fifteenMinutes(15), twentyMinutes(20), thirtyMinutes(30), sixtyMinutes(60), oneTwentyMinutes(120), oneEightyMinutes(180), twoFortyMinutes(240)} | read-write | deprecated |
| userAuthenticationMethod OBJECT-TYPE Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified. | 1.3.6.1.4.1.2.3.51.2.4.1.1.7 | INTEGER {localOnly(0), ldapOnly(1), localFirstThenLdap(2), ldapFirstThenLocal(3)} | read-write | mandatory |
| maxSessionsPerLDAPUser OBJECT-TYPE The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | 1.3.6.1.4.1.2.3.51.2.4.1.1.9 | INTEGER | read-write | mandatory |
| authenticationLoggingTimeout OBJECT-TYPE Use this option to set how long, in seconds, AMM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events. | 1.3.6.1.4.1.2.3.51.2.4.1.1.10 | INTEGER {logAll(0), fiveSeconds(1), thirtySeconds(2), oneMinute(3), fiveMinutes(4), tenMinutes(5), thirtyMinutes(6), oneHour(7), twelveHours(8), oneDay(9), logNone(255)} | read-write | mandatory |
| trackingIP OBJECT-TYPE This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'. | 1.3.6.1.4.1.2.3.51.2.4.1.1.11 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| accountSecurityManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1.20 | |||
| accountSecurityLevel OBJECT-TYPE The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.1 | INTEGER {legacy(0), high(1), custom(2)} | read-write | mandatory |
| customSecuritySettings OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2 | |||
| loginPasswordRequired OBJECT-TYPE If enabled, all users require a login password to access the AMM. If disabled, empty password is allowed and complex password rules will be disabled automatically. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| passwordExpirationPeriod OBJECT-TYPE The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2 | INTEGER | read-write | mandatory |
| defaultAdminPasswordExpired OBJECT-TYPE If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| minimumPasswordReuseCycle OBJECT-TYPE The number of unique passwords a user must choose before reusing a password. The default value is none. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4 | INTEGER {none(0), onePassword(1), twoPasswords(2), threePasswords(3), fourPasswords(4), fivePasswords(5)} | read-write | mandatory |
| complexPasswordRules OBJECT-TYPE If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The rules are as follows: Passwords must be a minimum of eight characters. Passwords must not be a repeat or reverse of the associated login id. Passwords must be no more than three of the same characters used consecutively. Passwords must contain at least three of the following combinations: At least one lower case alphanumeric character. At least one upper case alphanumeric character. At least one numeric character. At least one special character. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| minimumDiffCharsPassword OBJECT-TYPE The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0) | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6 | INTEGER {none(0), oneChar(1), twoChars(2), threeChars(3), fourChars(4), fiveChars(5), sixChars(6), sevenChars(7), eightChars(8), nineChars(9), tenChars(10), elevenChars(11), twelveChars(12), thirteenChars(13), fourteenChars(14), fifteenChars(15)} | read-write | mandatory |
| changePasswordFirstAccess OBJECT-TYPE If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| inactivityAlertPeriod OBJECT-TYPE The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8 | INTEGER | read-write | mandatory |
| inactivityAlertDisablePeriod OBJECT-TYPE The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9 | INTEGER | read-write | mandatory |
| lockoutPeriod OBJECT-TYPE The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10 | INTEGER | read-write | mandatory |
| maxLoginFailures OBJECT-TYPE The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11 | INTEGER {none(0), oneTime(1), twoTimes(2), threeTimes(3), fourTimes(4), fiveTimes(5), sixTimes(6), sevenTimes(7), eightTimes(8), nineTimes(9), tenTimes(10)} | read-write | mandatory |
| passwordChangeInterval OBJECT-TYPE A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval. | 1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12 | INTEGER | read-write | mandatory |
| serialPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.2 | |||
| portBaud OBJECT-TYPE Baud rate for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.1 | INTEGER {baud2400(0), baud4800(1), baud9600(3), baud19200(7), baud38400(15), baud57600(23)} | read-write | mandatory |
| portParity OBJECT-TYPE Parity setting for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.2 | INTEGER {none(0), odd(1), even(3), mark(5), space(7)} | read-write | mandatory |
| portStopBits OBJECT-TYPE Number of stop bits for the serial port. | 1.3.6.1.4.1.2.3.51.2.4.1.2.3 | INTEGER {oneStopbit(0), twoOrOnePtFive(1)} | read-write | mandatory |
| remoteAlertIds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.3 | |||
| remoteAlertIdsTable OBJECT-TYPE Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1 | not-accessible | mandatory | |
| remoteAlertIdsEntry OBJECT-TYPE Remote alert entries. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1 | not-accessible | mandatory | |
| remoteAlertIdEntryIndex OBJECT-TYPE Index for remote alert entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1 | INTEGER | read-only | mandatory |
| remoteAlertIdEntryStatus OBJECT-TYPE Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2 | INTEGER {invalid(0), disabledAndValid(1), enabledAndValid(2)} | read-write | mandatory |
| remoteAlertIdEntryIpOrHostAddress OBJECT-TYPE A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3 | OCTET STRING (SIZE(0..50)) | read-write | mandatory |
| remoteAlertIdEntryTextDescription OBJECT-TYPE A null terminated string that contains a text description of this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4 | OCTET STRING (SIZE(0..50)) | read-write | mandatory |
| remoteAlertIdEntryNotificationType OBJECT-TYPE Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), ibmDirectorOverLAN for a LAN alert sent over ethernet to IBM director, snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5 | INTEGER {unknown(0), snmpOverLan(4), emailOverLan(5), ibmDirectorOverLAN(8)} | read-write | mandatory |
| remoteAlertIdEmailAddr OBJECT-TYPE A null terminated string that contains an E-Mail Address. For example, 'jeb@us.ibm.com'. Used only for an E-mail over LAN or E-Mail over PPP notification type. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| remoteAlertIdEntrySelectiveAlert OBJECT-TYPE Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient. | 1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13 | INTEGER {critOnlyAlerts(0), allAlerts(1)} | read-write | mandatory |
| generateTestAlert OBJECT-TYPE Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. The text portion of the alert will contain 'Application Posted Alert to MM'. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.3.30 | INTEGER {execute(1)} | read-write | mandatory |
| remoteAccessIds OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.4 | |||
| remoteAccessIdsTable OBJECT-TYPE Table of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1 | not-accessible | mandatory | |
| remoteAccessIdsEntry OBJECT-TYPE Remote access entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1 | not-accessible | mandatory | |
| remoteAccessIdEntryIndex OBJECT-TYPE Index for Remote access entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| remoteAccessIdEntryUserId OBJECT-TYPE Remote access entry null terminated string that contains the user-id. It must not be a duplicate of any previously configured ones. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| remoteAccessIdEntryPassword OBJECT-TYPE Remote access password. The password must contain at least one alphabetic and one non-alphabetic character and be at least 5 characters long, or you can leave the password field blank to set an empty password. NOTE: Value returned by the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| remoteAccessIdEntryEncodedLoginPw OBJECT-TYPE Used only for configuration save/restore. A null terminated string containing an encoded concatenation of the login ID and password separated by an ':'. This object is no longer supported and will return a string of asterisks | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.7 | OCTET STRING (SIZE(0..36)) | read-write | deprecated |
| remoteAccessIdEntryRole OBJECT-TYPE Indicates if user has supervisor, operator, or custom access. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10 | OCTET STRING | read-only | mandatory |
| remoteAccessIdEntryLoggedIn OBJECT-TYPE Indicates if user is currently logged in or not. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryLastLogin OBJECT-TYPE Timestamp for the last successful login by the user. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12 | OCTET STRING | read-only | mandatory |
| remoteAccessIdEntryPwdCompliant OBJECT-TYPE Indicates if user complies with all of the password rules currently in effect. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryPwdExp OBJECT-TYPE The number of days until the user's current password expires. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14 | OCTET STRING | read-only | mandatory |
| remoteAccessIdEntryDormant OBJECT-TYPE Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| remoteAccessIdEntryState OBJECT-TYPE Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16 | INTEGER {disabled(0), active(1), locked(2)} | read-only | mandatory |
| remoteAccessIdEntryAction OBJECT-TYPE Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17 | INTEGER {disable(0), enable(1), unlock(2), notApplicable(255)} | read-write | mandatory |
| remoteAccessIdEntrySessionCount OBJECT-TYPE The number of sessions the user is currently logged in to. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18 | INTEGER | read-only | mandatory |
| remoteAccessIdEntryMaxSessions OBJECT-TYPE The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20. | 1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19 | INTEGER | read-write | mandatory |
| remoteAccessUserAuthorityLevelTable OBJECT-TYPE Table of user authority level profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2 | not-accessible | mandatory | |
| remoteAccessUserAuthorityLevelEntry OBJECT-TYPE User authority level entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1 | not-accessible | mandatory | |
| ualIndex OBJECT-TYPE Index for User Authority Level entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.1 | INTEGER (0..255) | read-only | mandatory |
| ualId OBJECT-TYPE User ID | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| ualSupervisor OBJECT-TYPE User has no restrictions. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualReadOnly OBJECT-TYPE User has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualAccountManagement OBJECT-TYPE User can add/modify/delete users and change the global login settings in the Login Profiles panel. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualConsoleAccess OBJECT-TYPE User can access the remote console. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualConsoleAndVirtualMediaAccess OBJECT-TYPE User can access both the remote console and the virtual media feature. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualServerPowerAccess OBJECT-TYPE User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualAllowClearLog OBJECT-TYPE User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualAdapterBasicConfig OBJECT-TYPE User can modify configuration parameters in the System Settings and Alerts panels. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualAdapterNetworkAndSecurityConfig OBJECT-TYPE User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ualAdapterAdvancedConfig OBJECT-TYPE User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the RSA, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter. | 1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAccessRBSroleTable OBJECT-TYPE Table of RBS User Role profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3 | not-accessible | mandatory | |
| remoteAccessRBSroleEntry OBJECT-TYPE User Role entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1 | not-accessible | mandatory | |
| roleIndex OBJECT-TYPE Index for RBS User Role entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1 | INTEGER (0..255) | read-only | mandatory |
| roleId OBJECT-TYPE User ID | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| rbsSupervisor OBJECT-TYPE User has no restrictions. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsOperator OBJECT-TYPE User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisOperator OBJECT-TYPE User has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisAccountManagement OBJECT-TYPE User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisLogManagement OBJECT-TYPE User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisConfiguration OBJECT-TYPE User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsChassisAdministration OBJECT-TYPE User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeOperator OBJECT-TYPE User has ability to browse status and properties of blades. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeRemotePresence OBJECT-TYPE User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeConfiguration OBJECT-TYPE User can modify and save any blade configuration parameter. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeAdministration OBJECT-TYPE User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleOperator OBJECT-TYPE User has ability to browse status and properties of I/O Modules, and to ping I/O Modules. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleConfiguration OBJECT-TYPE User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitchModuleAdministration OBJECT-TYPE User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBladeRemotePresenseVideo OBJECT-TYPE User can browser Remote Control web panel and remote blade video. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| rbsBladeRemotePresenseKVM OBJECT-TYPE User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.18 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| rbsBladeRemotePresenseRdriveR OBJECT-TYPE User can mount remote blade driver, and have read access only. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.19 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| rbsBladeRemotePresenseRdriveRW OBJECT-TYPE User can mount remote blade driver and have read/write access. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| rbsChassisRemotePresenseRdoc OBJECT-TYPE User has ability to upload/delete own image to RDOC and also can start remote control web panel. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.21 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| rbsRemotePresenceSupervisor OBJECT-TYPE User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote driver read/write, upload/delete himself and other's image to RDOC. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool. | 1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| remoteAccessRBSscopeTable OBJECT-TYPE Table of RBS User Scope profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4 | not-accessible | mandatory | |
| remoteAccessRBSscopeEntry OBJECT-TYPE User Scope entries. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1 | not-accessible | mandatory | |
| scopeIndex OBJECT-TYPE Index for RBS User Scope Entry. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1 | INTEGER (0..255) | read-only | mandatory |
| scopeId OBJECT-TYPE User ID | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| rbsChassis OBJECT-TYPE User has access to the MM and chassis functions. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade1 OBJECT-TYPE User has access to the blade in slot 1. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade2 OBJECT-TYPE User has access to the blade in slot 2. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade3 OBJECT-TYPE User has access to the blade in slot 3. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade4 OBJECT-TYPE User has access to the blade in slot 4. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade5 OBJECT-TYPE User has access to the blade in slot 5. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade6 OBJECT-TYPE User has access to the blade in slot 6. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade7 OBJECT-TYPE User has access to the blade in slot 7. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade8 OBJECT-TYPE User has access to the blade in slot 8. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade9 OBJECT-TYPE User has access to the blade in slot 9. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade10 OBJECT-TYPE User has access to the blade in slot 10. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade11 OBJECT-TYPE User has access to the blade in slot 11. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade12 OBJECT-TYPE User has access to the blade in slot 12. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade13 OBJECT-TYPE User has access to the blade in slot 13. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsBlade14 OBJECT-TYPE User has access to the blade in slot 14. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch1 OBJECT-TYPE User has access to I/O module 1. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch2 OBJECT-TYPE User has access to I/O module 2. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch3 OBJECT-TYPE User has access to I/O module 3. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch4 OBJECT-TYPE User has access to I/O module 4. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch5 OBJECT-TYPE User has access to I/O module 5. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch6 OBJECT-TYPE User has access to I/O module 6. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch7 OBJECT-TYPE User has access to I/O module 7. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch8 OBJECT-TYPE User has access to I/O module 8. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch9 OBJECT-TYPE User has access to I/O module 9. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rbsSwitch10 OBJECT-TYPE User has access to I/O module 10. | 1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| userInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.5 | |||
| cli OBJECT-TYPE Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled. | 1.3.6.1.4.1.2.3.51.2.4.1.5.1 | INTEGER {disabled(0), telnet-only(1), ssh-only(2), enabled(3)} | read-write | mandatory |
| snmp OBJECT-TYPE Enable/Disable SNMP v1 and v3 access to the MM. | 1.3.6.1.4.1.2.3.51.2.4.1.5.2 | INTEGER {disabled(0), v1-only(1), v3-only(2), enabled(3)} | read-write | mandatory |
| tcm OBJECT-TYPE Enable/Disable TCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. | 1.3.6.1.4.1.2.3.51.2.4.1.5.3 | INTEGER (0..20) | read-write | mandatory |
| web OBJECT-TYPE Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser. | 1.3.6.1.4.1.2.3.51.2.4.1.5.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| stcm OBJECT-TYPE Enable/Disable STCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. | 1.3.6.1.4.1.2.3.51.2.4.1.5.5 | INTEGER (0..20) | read-write | mandatory |
| mmSshClientAuth OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.6 | |||
| mmSshClientAuthPubKeyTable OBJECT-TYPE A table that contains client authentication public key information. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1 | not-accessible | mandatory | |
| mmSshClientAuthPubKeyEntry OBJECT-TYPE A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1 | not-accessible | mandatory | |
| mmSshClientAuthRemoteAccessIdIndex OBJECT-TYPE The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1 | INTEGER | not-accessible | mandatory |
| mmSshClientAuthPubKeyIndex OBJECT-TYPE The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2 | INTEGER | not-accessible | mandatory |
| mmSshClientAuthPubKeyType OBJECT-TYPE The type of the SSH public key represented by this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3 | INTEGER {sshDss(1), sshRsa(2)} | read-only | mandatory |
| mmSshClientAuthPubKeySize OBJECT-TYPE The size of the SSH public key represented by this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4 | INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)} | read-only | mandatory |
| mmSshClientAuthPubKeyFingerprint OBJECT-TYPE The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5 | OCTET STRING | read-only | mandatory |
| mmSshClientAuthPubKeyAcceptFrom OBJECT-TYPE This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyComment OBJECT-TYPE This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyAction OBJECT-TYPE import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the AMM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8 | INTEGER {import(1), export(2)} | read-write | mandatory |
| mmSshClientAuthPubKeyEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it. | 1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9 | EntryStatus | read-write | mandatory |
| mmSshClientAuthPubKeyUnused OBJECT-TYPE The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration. | 1.3.6.1.4.1.2.3.51.2.4.1.6.2 | INTEGER | read-only | mandatory |
| mmSshClientAuthPubKeyTftpServer OBJECT-TYPE IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). | 1.3.6.1.4.1.2.3.51.2.4.1.6.3 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyFileName OBJECT-TYPE File name on the TFTP server of an SSH client authentication public key. | 1.3.6.1.4.1.2.3.51.2.4.1.6.4 | OCTET STRING | read-write | mandatory |
| mmSshClientAuthPubKeyFileFormat OBJECT-TYPE File format of SSH client authentication public key files imported from or exported to the TFTP file server. | 1.3.6.1.4.1.2.3.51.2.4.1.6.5 | INTEGER {openSSH(1), rfc4716(2)} | read-write | mandatory |
| groupProfiles OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.1.7 | |||
| groupIdsTable OBJECT-TYPE Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1 | not-accessible | mandatory | |
| groupIdsEntry OBJECT-TYPE Group ID entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1 | not-accessible | mandatory | |
| groupIndex OBJECT-TYPE Index for Group IDs entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupId OBJECT-TYPE Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| groupRole OBJECT-TYPE Group Role. It indicates if the group has supervisor, operator, or custom access. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3 | OCTET STRING | read-only | mandatory |
| groupEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9 | EntryStatus | read-write | mandatory |
| groupRBSroleTable OBJECT-TYPE Table of Group Role profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2 | not-accessible | mandatory | |
| groupRBSroleEntry OBJECT-TYPE Group Role entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1 | not-accessible | mandatory | |
| groupRBSroleIndex OBJECT-TYPE Index for Group Role entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupRBSroleId OBJECT-TYPE Group ID | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| groupRBSSupervisor OBJECT-TYPE Group has no restrictions. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSOperator OBJECT-TYPE Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.). | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisOperator OBJECT-TYPE Group has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisAccountManagement OBJECT-TYPE Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisLogManagement OBJECT-TYPE Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisConfiguration OBJECT-TYPE Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSChassisAdministration OBJECT-TYPE Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeOperator OBJECT-TYPE Group has ability to browse status and properties of blades. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeRemotePresence OBJECT-TYPE Group has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeConfiguration OBJECT-TYPE Group can modify and save any blade configuration parameter. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBladeAdministration OBJECT-TYPE Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleOperator OBJECT-TYPE Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleConfiguration OBJECT-TYPE Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitchModuleAdministration OBJECT-TYPE Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module. | 1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSscopeTable OBJECT-TYPE Table of Group Scope profiles. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3 | not-accessible | mandatory | |
| groupRBSscopeEntry OBJECT-TYPE Group Scope entries. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1 | not-accessible | mandatory | |
| groupRBSscopeIndex OBJECT-TYPE Index for Group Scope Entry. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1 | INTEGER (0..255) | read-only | mandatory |
| groupRBSscopeId OBJECT-TYPE Group ID | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| groupRBSChassis OBJECT-TYPE Group has access to the MM and chassis functions. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade1 OBJECT-TYPE Group has access to the blade in slot 1. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade2 OBJECT-TYPE Group has access to the blade in slot 2. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade3 OBJECT-TYPE Group has access to the blade in slot 3. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade4 OBJECT-TYPE Group has access to the blade in slot 4. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade5 OBJECT-TYPE Group has access to the blade in slot 5. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade6 OBJECT-TYPE Group has access to the blade in slot 6. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade7 OBJECT-TYPE Group has access to the blade in slot 7. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade8 OBJECT-TYPE Group has access to the blade in slot 8. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade9 OBJECT-TYPE Group has access to the blade in slot 9. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade10 OBJECT-TYPE Group has access to the blade in slot 10. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade11 OBJECT-TYPE Group has access to the blade in slot 11. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade12 OBJECT-TYPE Group has access to the blade in slot 12. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade13 OBJECT-TYPE Group has access to the blade in slot 13. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSBlade14 OBJECT-TYPE Group has access to the blade in slot 14. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch1 OBJECT-TYPE Group has access to I/O module 1. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch2 OBJECT-TYPE Group has access to I/O module 2. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch3 OBJECT-TYPE Group has access to I/O module 3. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch4 OBJECT-TYPE Group has access to I/O module 4. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch5 OBJECT-TYPE Group has access to I/O module 5. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch6 OBJECT-TYPE Group has access to I/O module 6. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch7 OBJECT-TYPE Group has access to I/O module 7. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch8 OBJECT-TYPE Group has access to I/O module 8. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch9 OBJECT-TYPE Group has access to I/O module 9. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| groupRBSSwitch10 OBJECT-TYPE Group has access to I/O module 10. | 1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlerts OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2 | |||
| remoteAlertsCrit OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.1 | |||
| critTemp OBJECT-TYPE Generate an alert if any of the monitored temperature sensors in the system exceed their critical threshold. NOTE: If a critical Temperature condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.1 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critVolt OBJECT-TYPE Generate a alert if any of the monitored power supply sensors in the system fall outside their specified critical operational range. NOTE: If a critical voltage condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.2 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critMultiBlower OBJECT-TYPE Generate an alert if multiple blowers used for cooling the system fail. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.4 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critPower OBJECT-TYPE Generate an alert if any of the system power supplies fail. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critHardDrive OBJECT-TYPE Generate an alert if any of hard disk drives fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.6 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critVRM OBJECT-TYPE Generate an alert if any of VRM (voltage regulator modules) fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.7 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critMultipleSwitchModule OBJECT-TYPE Generate an alert if all switch modules fail or are removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.8 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critInvalidConfig OBJECT-TYPE Generate an alert if the hardware configuration is incompatible. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.1.9 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| critBlade OBJECT-TYPE Generate an alert for any critical error condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critIO OBJECT-TYPE Generate an alert for any critical error condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critStorage OBJECT-TYPE Generate an alert for any critical error condition on a Storage module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.4.2.1.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critChassis OBJECT-TYPE Generate an alert for any critical error condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.1.13 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| critFan OBJECT-TYPE Generate an alert for any critical error condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.1.14 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlertsNonCrit OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.2 | |||
| warnSingleBlower OBJECT-TYPE Generate an alert if one blower used for cooling the system fails. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.2.2 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| warnTemp OBJECT-TYPE Generate an alert if any of the monitored temperature sensors in the system exceed their warning threshold. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.2.3 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| warnVoltage OBJECT-TYPE Generate an alert if any of the monitored power supply sensors in the system fall outside their specified warning operational range. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.2.4 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| warnRedundantModule OBJECT-TYPE Generate an alert if any of the switch modules or management modules is failing or removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.2.6 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| warnMediaTrayKVMSwitch OBJECT-TYPE Generate an alert if the system detects a Media Tray or KVM switching failure. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.2.7 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| warnLogFull OBJECT-TYPE Generate an alert if the system log reaches 100% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnBlade OBJECT-TYPE Generate an alert for any warning condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnIO OBJECT-TYPE Generate an alert for any warning condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnStorage OBJECT-TYPE Generate an alert for any warning condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnPower OBJECT-TYPE Generate an alert for any warning condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnChassis OBJECT-TYPE Generate an alert for any warning condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| warnFan OBJECT-TYPE Generate an alert for any warning condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.2.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteAlertsSystem OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.2.3 | |||
| systemPowerOff OBJECT-TYPE Generate an alert if the system is powered off. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.3.4 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| systemPowerOn OBJECT-TYPE Generate a alert if the system is powered on. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.3.5 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| systemPFA OBJECT-TYPE Generate a alert if the system hardware detects a Predictive Failure Analysis(PFA) on PFA enabled hardware. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.3.8 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| systemInventory OBJECT-TYPE Generate an alert if the a processor blade or media tray is added or removed. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemLog75PctFull OBJECT-TYPE Generate an alert if the system log reaches 75% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| networkChangeNotification OBJECT-TYPE Generate an alert if the SP has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.12 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemBladeThrottling OBJECT-TYPE Generate an alert if any of the server blades are throttling. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.3.13 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| systemPowerManagement OBJECT-TYPE Generate an alert if the system detects a power oversubscription condition or power supply mismatch in a power domain. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. | 1.3.6.1.4.1.2.3.51.2.4.2.3.14 | INTEGER {disabled(0), enabled(1)} | read-only | deprecated |
| systemRemoteLogin OBJECT-TYPE Generate an alert if the system detects a new user logged in from a remote site. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemBlade OBJECT-TYPE Generate an alert for any informational condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemIO OBJECT-TYPE Generate an alert for any informational condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemStorage OBJECT-TYPE Generate an alert for any informational condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.18 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemPower OBJECT-TYPE Generate an alert for any informational condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemChassis OBJECT-TYPE Generate an alert for any informational condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemFan OBJECT-TYPE Generate an alert for any informational condition on cooling device. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| systemPWRDO OBJECT-TYPE Generate an alert for any informational condition on power on and power off. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. | 1.3.6.1.4.1.2.3.51.2.4.2.3.22 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| alertMode OBJECT-TYPE Selects which alert categories will be displayed on the web interface, which alert category objects are accessible through SNMP, and which SNMP trap type an alert is associated with. The enhanced option provides a component based category category scheme and is the only one that is now supported. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. Therefore, this setting should have a value of enhanced(1). | 1.3.6.1.4.1.2.3.51.2.4.2.4 | INTEGER {legacy(0), enhanced(1)} | read-write | mandatory |
| securitySettings OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.3 | |||
| dataEncryption OBJECT-TYPE If enabled, all confidential data will be encrypted. The default value is disabled. NOTE: Once the data is encrypted, the only way to reverse this process is to reset to default values. | 1.3.6.1.4.1.2.3.51.2.4.3.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| trespassWarning OBJECT-TYPE If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces. | 1.3.6.1.4.1.2.3.51.2.4.3.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| trespassWarningDefault OBJECT-TYPE Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.3.3 | INTEGER {execute(1)} | read-write | mandatory |
| trespassMessage OBJECT-TYPE The value of the trespass warning message. | 1.3.6.1.4.1.2.3.51.2.4.3.4 | OCTET STRING (SIZE(0..1600)) | read-write | mandatory |
| spClock OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.4 | |||
| spClockDateAndTimeSetting OBJECT-TYPE MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59 | 1.3.6.1.4.1.2.3.51.2.4.4.1 | OCTET STRING | read-write | mandatory |
| spClockTimezoneSetting OBJECT-TYPE MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is not observed in time zones where the 'Observe DST' value does not contain 'yes' in the table. Also, note that in some cases additional information is required to determine the clock adjustment when DST is observed. The additional information is required when the GMT offset being written is +2:00 or +10:00. Examples -to set the GMT offset to +3:30, set the value to:'+3:30,no' -for Eastern Standard Time and observing DST, set the value to:'-5:00,yes' -for Egypt and observing DST, set the value to:'+2:00,yes,6' GMT Observe Additional Offset DST? DST value ______ _______ __________ +0:00 yes|no +1:00 yes|no +2:00 yes|no When 'Observe DST?' value is 'yes': 5 (for E.Europe) 4 (for GTB) 6 (for Egypt) 7 (for FLE) +3:00 yes|no +3:30 yes|no +4:00 no +4:30 no +5:00 yes|no +5:30 no +6:00 no +7:00 no +8:00 yes|no +9:00 yes|no +9:30 yes|no When 'Observe DST?' value is 'yes': 10 (for South AUS) 9 (for other locations) +10:00 yes|no When 'Observe DST?' value is 'yes': 9 (for AUS Eastern) 10 (for TAS,ACT,NSW,VIC) 4 (for Vladivostok) +11:00 no +12:00 yes|no -12:00 no -11:00 no -10:00 no -9:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -8:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -7:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -6:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -5:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -4:00 yes|no When 'Observe DST' value is 'yes': 12 (for Canada) 1 (for other locations) -3:30 yes|no -3:00 yes|no -2:00 yes|no -1:00 yes|no | 1.3.6.1.4.1.2.3.51.2.4.4.2 | OCTET STRING | read-write | mandatory |
| spIdentification OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.5 | |||
| spTxtId OBJECT-TYPE MM text ID. NOTE: Do not put any 'space characters' at end of the ID. | 1.3.6.1.4.1.2.3.51.2.4.5.1 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| networkConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9 | |||
| networkInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1 | |||
| extEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.1 | |||
| extEthernetInterfaceType OBJECT-TYPE The type of interface. Indicates 'Ethernet-1'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| extEthernetInterfaceHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| extEthernetInterfaceIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.4 | IpAddress | read-write | mandatory |
| extEthernetInterfaceDataRate OBJECT-TYPE Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.5 | INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6)} | read-write | mandatory |
| extEthernetInterfaceDuplexSetting OBJECT-TYPE Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.6 | INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)} | read-write | mandatory |
| extEthernetInterfaceLAA OBJECT-TYPE Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.7 | OCTET STRING (SIZE(17)) | read-write | mandatory |
| extEthernetInterfaceDhcpEnabled OBJECT-TYPE Disable or enable DHCP on this interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.8 | INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)} | read-write | mandatory |
| extEthernetInterfaceGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.9 | IpAddress | read-write | mandatory |
| extEthernetInterfaceBIA OBJECT-TYPE Specifies the burned-in MAC (BIA) address. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.10 | OCTET STRING (SIZE(17)) | read-only | mandatory |
| extEthernetInterfaceMTU OBJECT-TYPE Contains the Maximum Transmission Unit(MTU) for the ethernet interface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.13 | INTEGER | read-write | mandatory |
| extEthernetInterfaceSubnetMask OBJECT-TYPE Contains the subnet mask for the ethernet interface | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.14 | IpAddress | read-write | mandatory |
| dhcpEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16 | |||
| dhcpHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| dhcpIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2 | IpAddress | read-only | mandatory |
| dhcpGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3 | IpAddress | read-only | mandatory |
| dhcpSubnetMask OBJECT-TYPE Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4 | IpAddress | read-only | mandatory |
| dhcpDomainName OBJECT-TYPE Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| dhcpDHCPServer OBJECT-TYPE Contains the DHCP server IP address used to acquire the DHCP settings. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6 | IpAddress | read-only | mandatory |
| dhcpPrimaryDNSServer OBJECT-TYPE Contains the Primary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7 | IpAddress | read-only | mandatory |
| dhcpSecondaryDNSServer OBJECT-TYPE Contains the Secondary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8 | IpAddress | read-only | mandatory |
| dhcpTertiaryDNSServer OBJECT-TYPE Contains the tertiary DNS server, assigned by the DHCP server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9 | IpAddress | read-only | mandatory |
| intEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.2 | |||
| intEthernetInterfaceType OBJECT-TYPE The type of interface. Indicates 'PPP-1'. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.1 | OCTET STRING (SIZE(0..16)) | read-only | deprecated |
| intEthernetInterfaceEnabled OBJECT-TYPE Disable or enable the internal ethernet interface. NOTE: To alter any of the configuration settings for the ethernet interface, the following procedure should be used: (1) This object should be set to 'interfaceDisabled' (2) Make the modifications to other settings (3) This object should be set to 'interfaceEnabled' (4) Restart the management module Also note that when attempting to enable this interface, the remote IP address is verified to be nonzero. If this verification fails, an error response will be returned and the internal ethernet interface will be left disabled. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.2 | INTEGER {interfaceDisabled(0), interfaceEnabled(1)} | read-write | deprecated |
| intEthernetInterfaceLocalIPAddress OBJECT-TYPE Contains the IP address for the MM side of the internal ethernet link. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.4 | IpAddress | read-write | deprecated |
| intEthernetInterfaceDataRate OBJECT-TYPE Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, or Auto. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.5 | INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5)} | read-only | deprecated |
| intEthernetInterfaceDuplexSetting OBJECT-TYPE Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.6 | INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)} | read-only | deprecated |
| intEthernetInterfaceLAA OBJECT-TYPE Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.7 | OCTET STRING (SIZE(17)) | read-write | deprecated |
| intEthernetInterfaceGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.9 | IpAddress | read-write | deprecated |
| intEthernetInterfaceBIA OBJECT-TYPE Specifies the burned-in MAC (BIA) address. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.10 | OCTET STRING (SIZE(17)) | read-only | deprecated |
| intEthernetInterfaceMTU OBJECT-TYPE Contains the Maximum Transmission Unit (MTU) for the ethernet interface NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.13 | INTEGER | read-only | deprecated |
| intEthernetInterfaceSubnetMask OBJECT-TYPE Contains the subnet mask for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.1.2.14 | IpAddress | read-write | deprecated |
| standbyExtEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.3 | |||
| standbyExtEthernetInterfaceType OBJECT-TYPE The type of interface. Indicates 'Ethernet-1'. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| standbyExtEthernetInterfaceHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| standbyExtEthernetInterfaceIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.4 | IpAddress | read-write | mandatory |
| standbyExtEthernetInterfaceDataRate OBJECT-TYPE Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.5 | INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6)} | read-write | mandatory |
| standbyExtEthernetInterfaceDuplexSetting OBJECT-TYPE Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.6 | INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)} | read-write | mandatory |
| standbyExtEthernetInterfaceLAA OBJECT-TYPE Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.7 | OCTET STRING (SIZE(17)) | read-write | mandatory |
| standbyExtEthernetInterfaceDhcpEnabled OBJECT-TYPE Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.8 | INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)} | read-write | mandatory |
| standbyExtEthernetInterfaceGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.9 | IpAddress | read-write | mandatory |
| standbyExtEthernetInterfaceBIA OBJECT-TYPE Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.10 | OCTET STRING (SIZE(17)) | read-only | mandatory |
| standbyExtEthernetInterfaceMTU OBJECT-TYPE Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.13 | INTEGER | read-write | mandatory |
| standbyExtEthernetInterfaceSubnetMask OBJECT-TYPE Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.14 | IpAddress | read-write | mandatory |
| advancedFailover OBJECT-TYPE User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, no swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.15 | INTEGER {off(0), ipnoswap(1), ipswap(2)} | read-write | mandatory |
| standbyDhcpEthernetInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16 | |||
| standbyDhcpHostName OBJECT-TYPE Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyDhcpIPAddress OBJECT-TYPE Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2 | IpAddress | read-only | mandatory |
| standbyDhcpGatewayIPAddress OBJECT-TYPE Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3 | IpAddress | read-only | mandatory |
| standbyDhcpSubnetMask OBJECT-TYPE Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4 | IpAddress | read-only | mandatory |
| standbyDhcpDomainName OBJECT-TYPE Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyDhcpDHCPServer OBJECT-TYPE Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6 | IpAddress | read-only | mandatory |
| standbyDhcpPrimaryDNSServer OBJECT-TYPE Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7 | IpAddress | read-only | mandatory |
| standbyDhcpSecondaryDNSServer OBJECT-TYPE Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8 | IpAddress | read-only | mandatory |
| standbyDhcpTertiaryDNSServer OBJECT-TYPE Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9 | IpAddress | read-only | mandatory |
| extEthernetInterfaceIPv6 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4 | |||
| extEthernetInterfaceIPv6Type OBJECT-TYPE The type of interface. Indicates 'Ethernet-1'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.1 | OCTET STRING (SIZE(0..16)) | read-only | mandatory |
| extEthernetInterfaceIPv6Enabled OBJECT-TYPE The current IPv6 enabled or disabled state of this AMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5 | |||
| extEthernetInterfaceIPv6LocalAddress OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1 | |||
| extEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceIPv6StaticIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2 | |||
| extEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE The IPv6 static IP address enabled or disabled state for the ethernet interface. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2 | InetAddressIPv6 | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3 | INTEGER (1..128) | read-write | mandatory |
| extEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4 | InetAddressIPv6 | read-write | mandatory |
| extEthernetInterfaceIPv6AutoIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3 | |||
| extEthernetInterfaceIPv6AutoIPConfigEnabled OBJECT-TYPE The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceDHCPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2 | |||
| extEthernetInterfaceDHCPv6Enabled OBJECT-TYPE The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6DomainName OBJECT-TYPE The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| extEthernetInterfaceDHCPv6PrimaryDNSServer OBJECT-TYPE The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6SecondaryDNSServer OBJECT-TYPE The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6TertiaryDNSServer OBJECT-TYPE The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceDHCPv6Server OBJECT-TYPE The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceIPv6StatelessAutoConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3 | |||
| extEthernetInterfaceIPv6StatelessAutoConfigEnabled OBJECT-TYPE The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE Table of stateless Auto-Config addresses entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2 | not-accessible | mandatory | |
| extEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE Stateless Auto-Config address entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1 | not-accessible | mandatory | |
| extEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1 | INTEGER | read-only | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2 | InetAddressIPv6 | read-only | mandatory |
| extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3 | INTEGER (1..128) | read-only | mandatory |
| standbyExtEthernetInterfaceIPv6 OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5 | |||
| standbyEthernetInterfaceIPv6LocalAddress OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1 | |||
| standbyEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE The IPv6 link local IP address for the standby AMM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2 | |||
| standbyEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE The IPv6 static IP address state for the AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE The IPv6 static IP address for the standby AMM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2 | InetAddressIPv6 | read-write | mandatory |
| standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE The IPv6 static IP address prefix length for the standyby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3 | INTEGER (1..128) | read-only | mandatory |
| standbyEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE The IPv6 static IP address default route for the standby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3 | |||
| standbyEthernetInterfaceDHCPv6Enabled OBJECT-TYPE The DHCPv6 enabled or disabled state for the standby AMM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE The IPv6 address for the standby AMM assigned by DHCPv6 server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceDHCPv6DomainName OBJECT-TYPE The 64 byte Domain Name for the standby AMM assigned by the DHCPv6 server. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4 | OCTET STRING (SIZE(0..64)) | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4 | not-accessible | mandatory | |
| standbyEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE Stateless Auto-Config address entries | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1 | not-accessible | mandatory | |
| standbyEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE Index for stateless Auto-Config addresses. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1 | INTEGER | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE The stateless Auto-Configuration IPv6 address. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2 | InetAddressIPv6 | read-only | mandatory |
| standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE The stateless Auto-Configration address prefix length. | 1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3 | INTEGER (1..128) | read-only | mandatory |
| ddnsStatus OBJECT-TYPE Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration. | 1.3.6.1.4.1.2.3.51.2.4.9.1.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| hostName OBJECT-TYPE Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName | 1.3.6.1.4.1.2.3.51.2.4.9.1.11 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| standbyHostName OBJECT-TYPE Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.12 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| domainName OBJECT-TYPE The user assigned DNS domain name. | 1.3.6.1.4.1.2.3.51.2.4.9.1.13 | OCTET STRING | read-write | mandatory |
| standbyDomainName OBJECT-TYPE The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.1.14 | OCTET STRING | read-write | mandatory |
| vlanConfigure OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.1.20 | |||
| vlanGlobalState OBJECT-TYPE This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the table, vlanTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.1 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanCommitTimeout OBJECT-TYPE This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.2 | INTEGER (1..255) | read-write | mandatory |
| vlanCommitState OBJECT-TYPE This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.3 | INTEGER {noChangesPending(1), commitNeeded(2), executeCommit(3)} | read-write | mandatory |
| vlanTable OBJECT-TYPE This table contains the VLAN configuration objects. The default entry has an vlanEntryIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanEntryStatus, at vlanEntryIndex=2 to the value of createRequest(2) and also setting the object, vlanEntryVlanId, at vlanEntryIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20 | not-accessible | mandatory | |
| vlanEntry OBJECT-TYPE VLAN entries. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1 | not-accessible | mandatory | |
| vlanEntryIndex OBJECT-TYPE Index for VLAN entry. If vlanEntryIndex is equal to 1, it is the Default VLAN entry and cannot be deleted. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1 | INTEGER (1..2) | read-only | mandatory |
| vlanEntryVlanId OBJECT-TYPE Valid VLAN ID. Allowed values are 1..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanEntryIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanEntryState set to enable(1) or restart(2) for this change to take effect. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2 | INTEGER (1..4094) | read-write | mandatory |
| vlanEntryName OBJECT-TYPE This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| vlanEntryStatus OBJECT-TYPE This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanEntryStatus = createRequest 2. Set vlanEntryVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) cannot be deleted. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4 | EntryStatus | read-write | mandatory |
| vlanEntryState OBJECT-TYPE This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5 | INTEGER {disable(0), enable(1), restart(2)} | read-write | mandatory |
| vlanEntrySOLAccess OBJECT-TYPE This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanEntrycKVMAccess OBJECT-TYPE This object allows the user to set whether the VLAN for this entry will have access to the installed cards for concurrent keyboard, video, and mouse (cKVM). Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.7 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanEntryTagging OBJECT-TYPE This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanEntryIndex value of 1. By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| vlanEntryIOModuleAccess OBJECT-TYPE This read-only object indicates whether the VLAN for this entry will have access to the IO Modules. Only the VLAN entry with the vlanEntryIndex value of 1 will report this object with the value of enable(1), all other entries will have a value of disable(0). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.9 | INTEGER {disable(0), enable(1)} | read-only | mandatory |
| vlanEntryVlanDefault OBJECT-TYPE This object specifies which vlanTable entry is the 'default entry'. By default, the entry with the vlanEntryIndex value of 1 will have this object set to true(1). Only one vlanTable entry can be designated as the VLAN default entry. Setting this object to true(1) for an entry will make this object false(0) for all other vlanTable entries. Only the vlanTable entry with this object set to true(1) will allow the vlanEntryTagging object to be configurable for this vlanEntryIndex index. | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.10 | INTEGER {false(0), true(1)} | read-write | mandatory |
| vlanEntryIPv4StaticAddress OBJECT-TYPE This object sets the IP address for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31 | IpAddress | read-write | mandatory |
| vlanEntryIPv4StaticGateway OBJECT-TYPE This object sets the IP address for the IP gateway for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32 | IpAddress | read-write | mandatory |
| vlanEntryIPv4StaticMask OBJECT-TYPE This object sets the subnet mask for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRoute1 OBJECT-TYPE This object sets the IP address of the subnet route 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRouteMask1 OBJECT-TYPE This object sets the subnet route mask 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRoute2 OBJECT-TYPE This object sets the IP address of the subnet route 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRouteMask2 OBJECT-TYPE This object sets the subnet route mask 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRoute3 OBJECT-TYPE This object sets the IP address of the subnet route 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55 | IpAddress | read-write | mandatory |
| vlanEntryIPv4SubnetRouteMask3 OBJECT-TYPE This object sets the subnet route mask 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1). | 1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56 | IpAddress | read-write | mandatory |
| tcpProtocols OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3 | |||
| snmpAgentConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1 | |||
| snmpSystemContact OBJECT-TYPE A NULL terminated 48 byte string that contains the SNMP agent contact name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.1 | OCTET STRING (SIZE(0..48)) | read-write | mandatory |
| snmpSystemLocation OBJECT-TYPE A NULL terminated 48 byte string that contains the SNMP agent location name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.2 | OCTET STRING (SIZE(0..48)) | read-write | mandatory |
| snmpSystemAgentTrapsDisable OBJECT-TYPE Disable or enable SNMP traps. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.3 | INTEGER {trapsEnabled(0), trapsDisabled(1)} | read-write | mandatory |
| snmpAgentCommunityConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4 | |||
| snmpCommunityTable OBJECT-TYPE Table of SNMP Community entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1 | not-accessible | mandatory | |
| snmpCommunityEntry OBJECT-TYPE SNMP community entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1 | not-accessible | mandatory | |
| snmpCommunityEntryIndex OBJECT-TYPE Index for SNMP Agent Community entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| snmpCommunityEntryCommunityName OBJECT-TYPE SNMP Community entry name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress1 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress2 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress3 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityViewType OBJECT-TYPE Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6 | INTEGER {read-Traps(1), write-Read-Traps(2), traps-Only(3)} | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress4 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.7 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress5 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.8 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress6 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.9 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress7 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.10 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress8 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.11 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress9 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.12 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress10 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.13 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress11 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.14 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpCommunityEntryCommunityIpAddress12 OBJECT-TYPE SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.15 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| snmpv1SystemAgentEnable OBJECT-TYPE Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| snmpv3SystemAgentEnable OBJECT-TYPE Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| snmpAgentUserProfileConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9 | |||
| snmpUserProfileTable OBJECT-TYPE Table of SNMPv3 User Profile entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1 | not-accessible | mandatory | |
| snmpUserProfileEntry OBJECT-TYPE SNMP User Profile entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1 | not-accessible | mandatory | |
| snmpUserProfileEntryIndex OBJECT-TYPE Index for SNMPv3 Agent User Profile entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| snmpUserProfileEntryContextName OBJECT-TYPE SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| snmpUserProfileEntryAuthProt OBJECT-TYPE SNMPv3 User Profile entry - Authentication Protocol supported by the user. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4 | INTEGER {none(1), md5(2), sha(3)} | read-write | mandatory |
| snmpUserProfileEntryPrivProt OBJECT-TYPE SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6 | INTEGER {none(1), des(2), aes(4)} | read-write | mandatory |
| snmpUserProfileEntryPrivPassword OBJECT-TYPE SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7 | OCTET STRING (SIZE(0..31)) | read-write | mandatory |
| snmpUserProfileEntryViewType OBJECT-TYPE SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8 | INTEGER {read-Traps(1), read-Write-Traps(2), traps-Only(3)} | read-write | mandatory |
| snmpUserProfileEntryIpAddress OBJECT-TYPE SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| dnsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.2 | |||
| dnsEnabled OBJECT-TYPE Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' (4) Restart the management module Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.1 | INTEGER {dnsDisabled(0), dnsEnabled(1)} | read-write | mandatory |
| dnsServerIPAddress1 OBJECT-TYPE Contains the primary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.2 | IpAddress | read-write | mandatory |
| dnsServerIPAddress2 OBJECT-TYPE Contains the secondary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.3 | IpAddress | read-write | mandatory |
| dnsServerIPAddress3 OBJECT-TYPE Contains the tertiary DNS server IP address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.4 | IpAddress | read-write | mandatory |
| dnsServerIPv6Address1 OBJECT-TYPE Contains the primary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.12 | InetAddressIPv6 | read-write | mandatory |
| dnsServerIPv6Address2 OBJECT-TYPE Contains the secondary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.13 | InetAddressIPv6 | read-write | mandatory |
| dnsServerIPv6Address3 OBJECT-TYPE Contains the tertiary IPv6 DNS server address. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.14 | InetAddressIPv6 | read-write | mandatory |
| dnsPriority OBJECT-TYPE Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.2.20 | INTEGER {ipv6(1), ipv4(2)} | read-write | mandatory |
| smtpConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.3 | |||
| smtpServerNameOrIPAddress OBJECT-TYPE A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.1 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| attachmentsToEmailAlerts OBJECT-TYPE Indicates if the service information should be attached to an email alert. | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.2 | INTEGER {noAttachments(0), attachServiceInformation(1)} | read-write | mandatory |
| smtpEmailDomain OBJECT-TYPE A NULL terminated string that contains the SMTP email domain. If this field is empty, the AMM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.3.3 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| tcpApplicationConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.4 | |||
| telnetInactivityTimeout OBJECT-TYPE Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.1 | INTEGER | read-write | mandatory |
| commandModeInactivityTimeout OBJECT-TYPE The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.2 | INTEGER | read-write | mandatory |
| secureCommandModeEnable OBJECT-TYPE Set Secure TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. NOTE: System Management Software requires this to be enabled for secure communication to the AMM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.3 | INTEGER | read-write | mandatory |
| commandModeEnable OBJECT-TYPE Set TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. NOTE: System Management Software requires this to be enabled for non-secure communication to the AMM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.4 | INTEGER | read-write | mandatory |
| slpAddrType OBJECT-TYPE Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.5 | INTEGER {multicast(0), broadcast(1)} | read-write | mandatory |
| slpMulticastAddr OBJECT-TYPE Service Locator Protocol Multicast address | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.6 | IpAddress | read-write | mandatory |
| slpEnable OBJECT-TYPE Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| telnetEnable OBJECT-TYPE Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sshEnable OBJECT-TYPE Disable/Enable SSH. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.10 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sshVersion OBJECT-TYPE When SSH is enabled, this object allows the user to configure whether the SSH server accepts all versions of client connections or whether it restricts the connectivity to the more secure version 2 only. NOTE: Only SSH version 2 is supported now. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.11 | INTEGER {allVersions(0), version2Only(1)} | read-write | mandatory |
| sslServerEnable OBJECT-TYPE Disable/Enable SSL Server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.15 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| sslClientEnable OBJECT-TYPE Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.16 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ftpEnable OBJECT-TYPE Disable/Enable FTP. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| tftpEnable OBJECT-TYPE Disable/Enable TFTP. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.19 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smashTelnetEnable OBJECT-TYPE Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over Telnet. This option is not available on all systems. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.20 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smashSshEnable OBJECT-TYPE Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. A valid SSH server key must be installed before enabling secure SMASH. This option is not available on all systems. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.21 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| tftpCreateEmptyFile OBJECT-TYPE This MIB object is no longer a requirement for TFTP and has been deprecated. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.22 | OCTET STRING | read-write | deprecated |
| ftpTimeout OBJECT-TYPE The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.23 | INTEGER | read-write | mandatory |
| rdEnable OBJECT-TYPE Disable/Enable Remote Disk. NOTE: Change to Remote Disk will take effect after the next restart of the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.24 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| rdocEnable OBJECT-TYPE Disable/Enable Remote Disk on Card. NOTE: Change to Remote Disk on Card will take effect after the next restart of the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.25 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| kvmEnable OBJECT-TYPE Disable/Enable KVM. NOTE: Change to KVM will take effect after the next restart of the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.26 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| mmSshServerConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27 | |||
| mmSshServerHostKeyTable OBJECT-TYPE A table that contains per public/private host key pair information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1 | not-accessible | mandatory | |
| mmSshServerHostKeyEntry OBJECT-TYPE A list of information about a particular public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1 | not-accessible | mandatory | |
| mmSshServerHostKeyIndex OBJECT-TYPE The index of the public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1 | INTEGER | read-only | mandatory |
| mmSshServerHostKeyType OBJECT-TYPE The type of the public/private host key pair. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2 | INTEGER {sshDss(1), sshRsa(2)} | read-only | mandatory |
| mmSshServerHostKeySize OBJECT-TYPE The size of the public/private host key pair. NOTE: The AMM supports only the bits2048 value. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3 | INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)} | read-only | mandatory |
| mmSshServerHostKeyFingerprint OBJECT-TYPE The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the AMM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4 | OCTET STRING | read-only | mandatory |
| mmSshServerHostKeyGenerate OBJECT-TYPE Initiate the new Host Keys generation process for the AMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2 | INTEGER {execute(1)} | read-write | mandatory |
| mmSshServerHostKeyGenerateProgress OBJECT-TYPE Indicate the progress of the key generation process. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3 | OCTET STRING | read-only | mandatory |
| rpEnable OBJECT-TYPE Disable/Enable Remote Presence. | 1.3.6.1.4.1.2.3.51.2.4.9.3.4.28 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| tcpPortAssignmentCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.5 | |||
| tcpPortsRestoreDefault OBJECT-TYPE Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 Remote Disk: 1044 Remote Disk-on-Card: 1045 Remote KVM: 3900 FTP: 21 FTP Data: 20 TFTP: 69 SMASH telnet: 50023 SMASH ssh: 50022 SLP: 427 Storage Description Service: 1046 NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.1 | INTEGER {execute(1)} | read-write | mandatory |
| httpPortAssignment OBJECT-TYPE HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.2 | INTEGER | read-write | mandatory |
| httpsPortAssignment OBJECT-TYPE SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.3 | INTEGER | read-write | mandatory |
| telnetPortAssignment OBJECT-TYPE Telnet port number. Default value is 23. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.4 | INTEGER | read-write | mandatory |
| sshPortAssignment OBJECT-TYPE SSH port number. Default value is 22. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.5 | INTEGER | read-write | mandatory |
| snmpAgentPortAssignment OBJECT-TYPE SNMP Agent port number. Default value is 161. Changes take effect after several seconds. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.6 | INTEGER | read-write | mandatory |
| snmpTrapsPortAssignment OBJECT-TYPE SNMP Traps port number. Default value is 162. Changes take effect after several seconds. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.7 | INTEGER | read-write | mandatory |
| commandModePortAssignment OBJECT-TYPE TCP Command Mode port number. Default value is 6090. Change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.8 | INTEGER | read-write | mandatory |
| secureCommandModePortAssignment OBJECT-TYPE Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.9 | INTEGER | read-write | mandatory |
| rdPortAssignment OBJECT-TYPE Remote Disk port number. Default value is 1044. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.10 | INTEGER | read-write | deprecated |
| rdocPortAssignment OBJECT-TYPE Remote Disk-on-Card port number. Default value is 1045. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.11 | INTEGER | read-write | deprecated |
| kvmPortAssignment OBJECT-TYPE Remote KVM port number. Default value is 3900. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.12 | INTEGER | read-write | deprecated |
| ftpPortAssignment OBJECT-TYPE FTP port number. Default value is 21. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.13 | INTEGER | read-write | mandatory |
| ftpDataPortAssignment OBJECT-TYPE FTP Data port number. Default value is 20. Port change will take effect immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.14 | INTEGER | read-write | mandatory |
| tftpPortAssignment OBJECT-TYPE TFTP port number. Default value is 69. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.15 | INTEGER | read-write | mandatory |
| smashTelnetPortAssignment OBJECT-TYPE The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over telnet. Default value is 50023. Change will take effect immediately. This option is not available on all systems. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.17 | INTEGER | read-write | mandatory |
| smashSshPortAssignment OBJECT-TYPE The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. Default value is 50022. This option is not available on all systems. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.18 | INTEGER | read-write | mandatory |
| slpPortAssignment OBJECT-TYPE Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.19 | INTEGER | read-write | mandatory |
| sdsPortAssignment OBJECT-TYPE Storage description service port number. Default value is 1046. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.20 | INTEGER | read-write | deprecated |
| rpPortAssignment OBJECT-TYPE Remote Presence port. Default value is 3900. This port cannot be disabled since it is the single service entry point for all the services provided by AMM RPServ to clients. | 1.3.6.1.4.1.2.3.51.2.4.9.3.5.21 | INTEGER | read-write | mandatory |
| ldapClientCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.6 | |||
| ldapServer1NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.1 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer1PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.2 | INTEGER | read-write | mandatory |
| ldapServer2NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.3 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer2PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.4 | INTEGER | read-write | mandatory |
| ldapServer3NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.5 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer3PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.6 | INTEGER | read-write | mandatory |
| ldapRootDN OBJECT-TYPE A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.7 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapUserSearchBaseDN OBJECT-TYPE As part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search request must specify the base DN for the actual search. This field specifies the base DN which should be used to search the User directory. This is a NULL terminated 255 byte string. An example might look like cn=users,dn=foobar,dn=com. If this field is left blank, the Root DN will be used as the search base instead. As mentioned, user searches are part of the authentication process. They are carried out to retrieve information about the user such as login permissions, callback number, and group memberships. For Version 2.0 LDAP clients, it is strongly encouraged that this parameter be configured, otherwise a search using the root DN may not succeed (as seen on Active Directory servers). NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.8 | OCTET STRING (SIZE(0..255)) | read-write | deprecated |
| ldapGroupFilter OBJECT-TYPE This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.9 | OCTET STRING (SIZE(0..511)) | read-write | mandatory |
| ldapBindingMethod OBJECT-TYPE On initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. Strict UPN: This is the same as UPN above, except that the userid must have the form someuser@somedomain. The string entered by the user will be parsed for the @ symbol. NOTE: strictUserPrincipalName(3) option is available on MM only. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.10 | INTEGER {anonymousAuthentication(0), clientAuthentication(1), userPrincipalName(2), strictUserPrincipalName(3)} | read-write | mandatory |
| ldapClientAuthenticationDN OBJECT-TYPE The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. The client DN is a NULL terminated 255 byte string. These parameters are configured here. Note that the password can be left blank. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.11 | OCTET STRING (SIZE(0..255)) | read-write | mandatory |
| ldapClientAuthenticationPassword OBJECT-TYPE The client authentication password | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.12 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| ldapUIDsearchAttribute OBJECT-TYPE When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.13 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapGroupSearchAttribute OBJECT-TYPE When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.14 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapLoginPermissionAttribute OBJECT-TYPE When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.15 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapUseDNSOrPreConfiguredServers OBJECT-TYPE The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.16 | INTEGER {usePreConfiguredLDAPServers(0), useDNSToFindLDAPServers(1)} | read-write | mandatory |
| ldapDomainSource OBJECT-TYPE The DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is joesmith@mycompany.com, the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.17 | INTEGER {extractSearchDomainFromLoginID(0), useOnlyConfiguredSearchDomainBelow(1), tryLoginFirstThenConfiguredValue(2)} | read-write | deprecated |
| ldapSearchDomain OBJECT-TYPE This parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.18 | OCTET STRING (SIZE(0..64)) | read-write | deprecated |
| ldapServiceName OBJECT-TYPE The DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.19 | OCTET STRING (SIZE(0..16)) | read-write | deprecated |
| ldapRBSModelCfg OBJECT-TYPE There are two mechanisms to authenticate and authorize users on the AMM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and AMMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. AMM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.20 | INTEGER {oldPermissionString(0), newRBSModel(1)} | read-write | mandatory |
| ldapTargetName OBJECT-TYPE When administrator chooses Enhanced Role Based Security authentication model, he can associate one AMM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The AMM target name can be looked as alias of AMM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character) | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.21 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| ldapAuthCfg OBJECT-TYPE If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.22 | INTEGER {authenticationAndAuthorization(0), authenticationOnly(1)} | read-write | mandatory |
| ldapForestName OBJECT-TYPE LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.23 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| ldapDomainName OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP Domain Name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.24 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer4NameOrIPAddress OBJECT-TYPE A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d). | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.25 | OCTET STRING (SIZE(0..256)) | read-write | mandatory |
| ldapServer4PortNumber OBJECT-TYPE LDAP server port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.6.26 | INTEGER | read-write | mandatory |
| uplinkCheckConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.7 | |||
| uplinkCheckEnabled OBJECT-TYPE Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.1 | INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)} | read-write | mandatory |
| uplinkCheckDelay OBJECT-TYPE Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.2 | INTEGER | read-write | mandatory |
| logicalUplinkDestination OBJECT-TYPE Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.3 | IpAddress | read-write | mandatory |
| logicalUplinkCheckEnabled OBJECT-TYPE Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.4 | INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)} | read-write | mandatory |
| logicalUplinkCheckDelay OBJECT-TYPE Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.5 | INTEGER | read-write | mandatory |
| physicalUplinkCheckDelayInSecs OBJECT-TYPE Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.6 | INTEGER | read-write | mandatory |
| logicalUplinkCheckDelayInSecs OBJECT-TYPE Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.7 | INTEGER | read-write | mandatory |
| logicalUplinkIPv6Destination OBJECT-TYPE Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: This MIB object is only applicable if IPv6 is enabled on the MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.8 | InetAddressIPv6 | read-write | mandatory |
| logicalUplinkFailoverPolicy OBJECT-TYPE Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.4.9.3.7.9 | INTEGER {either(1), both(2)} | read-write | mandatory |
| ntpConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.8 | |||
| ntpEnable OBJECT-TYPE Disable/Enable the NTP client. The client will update the AMM system clock at the frequency specified. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| ntpIpAddressHostname OBJECT-TYPE NTP server's IP address or hostname if DNS is enabled and configured. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| ntpUpdateFrequency OBJECT-TYPE The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the AMM clock can only be synchronized with the NTP server manually. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.3 | INTEGER | read-write | mandatory |
| ntpLastUpdate OBJECT-TYPE The date and time that the NTP server last updated the system clock. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.4 | OCTET STRING | read-only | mandatory |
| ntpUpdateClock OBJECT-TYPE Update the AMM system clock with the specified NTP server. A valid NTP server must be configured first. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.5 | INTEGER {execute(1)} | read-write | mandatory |
| ntpAuthEntry OBJECT-TYPE The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key index> must be an integer between 1 and 65535. <key type> must be M. <key> is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: <key index> <key type> It does not return the actual key. | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.6 | OCTET STRING | read-write | mandatory |
| ntpAuthEnable OBJECT-TYPE Enables/Disables NTP v3 authentication | 1.3.6.1.4.1.2.3.51.2.4.9.3.8.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| syslogConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.9 | |||
| syslogSevFilterLevel OBJECT-TYPE syslogSevFilterLevel error/warning/information . | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.1 | INTEGER {error(0), warning(1), information(2)} | read-write | mandatory |
| syslogCollectorConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2 | |||
| syslogCollectorTable OBJECT-TYPE Table of Syslog Collector entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1 | not-accessible | mandatory | |
| syslogCollectorEntry OBJECT-TYPE Syslog Collector entries | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1 | not-accessible | mandatory | |
| syslogCollectorIndex OBJECT-TYPE Index for Syslog Collector entry. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1 | INTEGER (0..255) | read-only | mandatory |
| syslogCollectorHostnameOrIpAddress OBJECT-TYPE Syslog Collector IP address or host name. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| syslogCollectorPort OBJECT-TYPE Syslog Collector port number. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3 | INTEGER (1..65535) | read-write | mandatory |
| syslogCollectorEnable OBJECT-TYPE Syslog Collector enable/disable. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| syslogTestPacket OBJECT-TYPE Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.4.9.3.9.3 | INTEGER {execute(1)} | read-write | mandatory |
| solConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10 | |||
| solGlobalConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10.1 | |||
| solEnable OBJECT-TYPE Disable/Enable SOL dynamically. | 1.3.6.1.4.1.2.3.51.2.4.10.1.1 | INTEGER {solDisabled(0), solEnabled(1)} | read-write | mandatory |
| solVlanId OBJECT-TYPE This is the virtual LAN ID for the internal management network between the MM and the Blade System Management Processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. | 1.3.6.1.4.1.2.3.51.2.4.10.1.2 | INTEGER | read-write | mandatory |
| solAccumulateTimeout OBJECT-TYPE This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms. | 1.3.6.1.4.1.2.3.51.2.4.10.1.3 | INTEGER | read-write | mandatory |
| solCharSendThreshold OBJECT-TYPE This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 255 | 1.3.6.1.4.1.2.3.51.2.4.10.1.4 | INTEGER | read-write | mandatory |
| solRetry OBJECT-TYPE Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired. | 1.3.6.1.4.1.2.3.51.2.4.10.1.5 | INTEGER | read-write | mandatory |
| solRetryInterval OBJECT-TYPE Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back. | 1.3.6.1.4.1.2.3.51.2.4.10.1.6 | INTEGER | read-write | mandatory |
| solExitToCliKeySeq OBJECT-TYPE This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (. | 1.3.6.1.4.1.2.3.51.2.4.10.1.7 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| solResetBladeKeySeq OBJECT-TYPE This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R. | 1.3.6.1.4.1.2.3.51.2.4.10.1.8 | OCTET STRING (SIZE(0..16)) | read-write | mandatory |
| solBladeConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.10.2 | |||
| solBladeTable OBJECT-TYPE SOL Blade configuration table. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1 | not-accessible | mandatory | |
| solBladeEntry OBJECT-TYPE SOL Blade table entry | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1 | not-accessible | mandatory | |
| solBladeIndex OBJECT-TYPE SOL Blade table index. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1 | INTEGER | read-only | mandatory |
| solBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2 | OCTET STRING | read-only | mandatory |
| solBladeEnable OBJECT-TYPE Disable or enable a SOL on a blade. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3 | INTEGER {solBladeDisabled(0), solBladeEnabled(1)} | read-write | mandatory |
| solBladeIpAddr OBJECT-TYPE IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4 | IpAddress | read-only | mandatory |
| solBladeSessionStatus OBJECT-TYPE Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5 | INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)} | read-only | mandatory |
| solBladeCapability OBJECT-TYPE Display whether or not the blade support SOL feature. | 1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6 | INTEGER {notSupport(0), support(1)} | read-only | mandatory |
| chassisInternalNetwork OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.11 | |||
| cinsSupported OBJECT-TYPE Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported. | 1.3.6.1.4.1.2.3.51.2.4.11.1 | INTEGER | read-only | mandatory |
| cinGlobalEnable OBJECT-TYPE Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: AMM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces. | 1.3.6.1.4.1.2.3.51.2.4.11.2 | INTEGER {cinDisabled(0), cinEnabled(1)} | read-write | mandatory |
| cinTable OBJECT-TYPE Chassis Internal Network (CIN) configuration table. | 1.3.6.1.4.1.2.3.51.2.4.11.3 | not-accessible | mandatory | |
| cinEntry OBJECT-TYPE Chassis Internal Network (CIN) table entry. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1 | not-accessible | mandatory | |
| cinIndex OBJECT-TYPE Chassis Internal Network (CIN) table index. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.1 | INTEGER | read-only | mandatory |
| cinDefExists OBJECT-TYPE Indicates if a Chassis Internal Network (CIN) definition exists for this index or not. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.2 | INTEGER {false(0), true(1)} | read-only | mandatory |
| cinDelete OBJECT-TYPE Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.3 | INTEGER {execute(1)} | read-write | mandatory |
| cinEnable OBJECT-TYPE Disable or enable a Chassis Internal Network (CIN) definition. Enabled: AMM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| cinId OBJECT-TYPE This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.5 | INTEGER | read-write | mandatory |
| cinIpAddress OBJECT-TYPE Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the AMM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of AMM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.6 | IpAddress | read-write | mandatory |
| cinIpv6Address OBJECT-TYPE Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address. | 1.3.6.1.4.1.2.3.51.2.4.11.3.1.7 | InetAddressIPv6 | read-write | mandatory |
| cinStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.11.4 | |||
| cinStatusTable OBJECT-TYPE Table of Chassis Internal Network (CIN) status entry information. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1 | not-accessible | mandatory | |
| cinStatusEntry OBJECT-TYPE Chassis Internal Network (CIN) status table entry. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1 | not-accessible | mandatory | |
| cinStatusIndex OBJECT-TYPE The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1 | INTEGER | read-only | mandatory |
| cinStatusString OBJECT-TYPE Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the AMM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2 | OCTET STRING | read-only | mandatory |
| cinPortConfigTable OBJECT-TYPE Chassis Internal Network (CIN) configuration table for viewing and configuring the protocol port information for a particular CIN entry. | 1.3.6.1.4.1.2.3.51.2.4.11.5 | not-accessible | mandatory | |
| cinPortConfigEntry OBJECT-TYPE Chassis Internal Network (CIN) entry for viewing and configuring the protocol port information for a particular CIN entry. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1 | not-accessible | mandatory | |
| cinPortConfigCINIndex OBJECT-TYPE The identifier for the particular CIN configuration that these protocol port definitions are associated with. This object is the same as the cinIndex value in the cinTable. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.1 | INTEGER | read-only | mandatory |
| cinPortConfigIndex OBJECT-TYPE The identifier of a particular CIN protocol port configuration for a given CIN configuration as specified by cinPortConfigCINIndex. There can be up to 16 unique protocol port definitions per CIN configuration. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.2 | INTEGER | read-only | mandatory |
| cinPortConfigProtocolID OBJECT-TYPE Indicates whether the port protocol definition is for a TCP or UDP port. If the value of notDefined(3) is returned, the entry has yet to be configured. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.3 | INTEGER {tcp(1), udp(2), notDefined(3)} | read-write | mandatory |
| cinPortConfigExternalPort OBJECT-TYPE The external port number specified for this port protocol definition, ranging from 1 to 65,534. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.4 | INTEGER | read-write | mandatory |
| cinPortConfigInternalPort OBJECT-TYPE The internal port number specified for this port protocol definition, ranging from 1 to 65,534. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.5 | INTEGER | read-write | mandatory |
| cinPortConfigEnable OBJECT-TYPE The status of this port protocol definition. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| cinPortConfigDirection OBJECT-TYPE The traffic direction specified for this port protocol definition. | 1.3.6.1.4.1.2.3.51.2.4.11.5.1.7 | INTEGER {incoming(1), outgoing(2)} | read-write | mandatory |
| configurationManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.4.15 | |||
| saveConfigurationToChassis OBJECT-TYPE Save the configuration settings from the AMM to the chassis. This operation may take several seconds. The input values for the SET command when AMM is installed in BladeCenter and BladeCenter T are: 1: Save the configuration settings in compressed(AMM) format. 2: Save the configuration settings in legacy(MM) format. This option has been deprecated. other: Invalid. The input values for the SET command when AMM is installed in BladeCenter H and BladeCenter HT are: 1: Save the configuration settings in compressed(AMM) format. other: Invalid. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.4.15.1 | INTEGER {compressedFormat(1), legacyFormat(2)} | read-write | mandatory |
| restoreConfigurationFromChassis OBJECT-TYPE Restore the configuration settings to the AMM from the BladeCenter chassis. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless. | 1.3.6.1.4.1.2.3.51.2.4.15.2 | INTEGER {execute(1)} | read-write | mandatory |
| autoReadConfigInNewChassis OBJECT-TYPE The AMM will automatically read configuration settings from the midplane every time the AMM is inserted into a new chassis. NOTE: This MIB object is for AMM only. | 1.3.6.1.4.1.2.3.51.2.4.15.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| telcoManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5 | |||
| telcoAlarmReq OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5.1 | |||
| telcoAlarmSet OBJECT-TYPE Create a software alarm. An input octet string consists of the alarm severity level and the alarm description (40 bytes max). The following severity levels are valid : CRT Critical MJR Major MNR Minor NOTE 1: The level (e.g. MJR) and alarm description string must be separated by a blank, otherwise, a badValue error will be returned. NOTE 2: Value returned for the GET command is meaningless for this MIB object. NOTE 3: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.5.1.1 | OCTET STRING | read-write | mandatory |
| telcoAlarmAck OBJECT-TYPE Acknowledge an alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE 1: Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.5.1.2 | OCTET STRING | read-write | mandatory |
| telcoAlarmClear OBJECT-TYPE Clear an active alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE1 : Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.5.1.3 | OCTET STRING | read-write | mandatory |
| telcoHWManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5.3 | |||
| tappowerReq OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5.3.1 | |||
| tappoweronoff OBJECT-TYPE Telco Alarm Panel power on or power off. If powering off a currently powered on Telco Alarm Panel, then all LEDs of this request card will be reset to OFF and the Safely Remove LED will be turned ON to indicate the card is safe for removal. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.5.3.1.1 | INTEGER {poweroff(0), poweron(1)} | read-write | mandatory |
| ncReq OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5.3.2 | |||
| ncReqTable OBJECT-TYPE Table of the Network Clock Module Operations. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.5.3.2.1 | not-accessible | deprecated | |
| ncReqEntry OBJECT-TYPE Network Clock Module Power ON/OFF entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1 | not-accessible | deprecated | |
| ncReqIndex OBJECT-TYPE Network Clock Module Request index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.1 | INTEGER (0..128) | read-only | deprecated |
| ncReqBayNumber OBJECT-TYPE Network Clock Module Request Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.2 | INTEGER {networkclock1(1), networkclock2(2)} | read-only | deprecated |
| ncReqPoweronoff OBJECT-TYPE Request to power on/off for the specified Network Clock Module. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.3 | INTEGER {poweroff(0), poweron(1)} | read-write | deprecated |
| telcoOEM OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.5.127 | |||
| telcoOEMs OBJECT-TYPE A bitmap of information about the contents of this subtree. The bitmap is a variable length string containing a list of 1's and 0's. Every bit that is set to 1 has a corresponding subtree entry that is supported in firmware, while a 0 means that the subtree entry is unavailable. NOTE: This MIB object is for BladeCenter T only. | 1.3.6.1.4.1.2.3.51.2.5.127.1 | OCTET STRING | read-only | mandatory |
| restartReset OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.7 | |||
| restartSPImmediately OBJECT-TYPE Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.4 | INTEGER {execute(1)} | read-write | mandatory |
| restartStandbyMM OBJECT-TYPE Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM. | 1.3.6.1.4.1.2.3.51.2.7.5 | INTEGER {execute(1)} | read-write | mandatory |
| switchOverRedundantMM OBJECT-TYPE Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM. | 1.3.6.1.4.1.2.3.51.2.7.7 | INTEGER {execute(1)} | read-write | mandatory |
| resetSPConfigAndRestart OBJECT-TYPE Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.20 | INTEGER {execute(1)} | read-write | mandatory |
| resetSPConfigAndRestartSaveLogs OBJECT-TYPE Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.7.21 | INTEGER {execute(1)} | read-write | mandatory |
| blades OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22 | |||
| processorBlade OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1 | |||
| bladeMediaTrayBladeId OBJECT-TYPE Allocate the media tray to a blade of a BladeCenter system. On a get command, a blade ID of 0x00 means that no blade is currently using the device. A set command cannot allocate the media tray to the management module. NOTE: A blade cannot be allocated to the media tray if the value of OID remoteMediaTraySwitchEnable of the blade is disabled. | 1.3.6.1.4.1.2.3.51.2.22.1.1 | INTEGER {managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-write | mandatory |
| bladeKVMBladeId OBJECT-TYPE Allocate the keyboard, video, and mouse ports (KVM) to a blade of a blade runner system. On a get command, a blade ID of 0x00 means that no blade is currently using the devices. A set command cannot allocate the KVM to the management module. | 1.3.6.1.4.1.2.3.51.2.22.1.2 | INTEGER {managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-write | mandatory |
| bladeBootSequenceTable OBJECT-TYPE Table of blade boot sequence information. Contains the boot sequence information for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.3 | not-accessible | mandatory | |
| bladeBootSequenceEntry OBJECT-TYPE Boot sequence entry | 1.3.6.1.4.1.2.3.51.2.22.1.3.1 | not-accessible | mandatory | |
| bootSequenceIndex OBJECT-TYPE Blade boot sequence index. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.1 | INTEGER | read-only | mandatory |
| bootSequenceBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bootSequenceBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bootSequenceBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bootSequenceBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)} | read-only | mandatory |
| bootSequenceBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.6 | OCTET STRING | read-only | mandatory |
| bootSequence1 OBJECT-TYPE The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.7 | INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)} | read-write | mandatory |
| bootSequence2 OBJECT-TYPE The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.8 | INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)} | read-write | mandatory |
| bootSequence3 OBJECT-TYPE The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.9 | INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)} | read-write | mandatory |
| bootSequence4 OBJECT-TYPE The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever. | 1.3.6.1.4.1.2.3.51.2.22.1.3.1.10 | INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)} | read-write | mandatory |
| bladeRemoteControl OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.4 | |||
| bladeRemoteControlTable OBJECT-TYPE Table of blade remote power control information. Contains power on/off enablement status for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1 | not-accessible | mandatory | |
| bladeRemoteControlEntry OBJECT-TYPE Remote power control entry | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1 | not-accessible | mandatory | |
| remoteControlIndex OBJECT-TYPE Blade remote power control index. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1 | INTEGER | read-only | mandatory |
| remoteControlBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| remoteControlBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| remoteControlBladePowerState OBJECT-TYPE The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| remoteControlBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)} | read-only | mandatory |
| remoteControlBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6 | OCTET STRING | read-only | mandatory |
| remotePowerControlEnable OBJECT-TYPE Blade remote power control enablement status. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteMediaTrayControlEnable OBJECT-TYPE Blade media tray enablement status. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.8 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteKVMControlEnable OBJECT-TYPE Blade KVM enablement status. Note that some types of blades don't support KVM | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.9 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| remoteWakeOnLanControlEnable OBJECT-TYPE Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| remoteMediaTraySwitchEnable OBJECT-TYPE Blade Remote Media Tray Switch enablement status. If the remote disk feature is disabled, this OID cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.11 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicy OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.4.2 | |||
| bladePolicyPowerControlEnable OBJECT-TYPE Blade remote power control enablement status policy. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyMediaTrayControlEnable OBJECT-TYPE Blade media tray enablement status policy. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyKVMControlEnable OBJECT-TYPE Blade KVM enablement status policy. Note that some types of blades don't support KVM. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyWakeOnLanControlEnable OBJECT-TYPE Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.4 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bladePolicyMediaTraySwitchEnable OBJECT-TYPE Blade Remote Media Tray Switch enablement status policy. If the remote disk feature is disabled, this OID cannot be set. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.5 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyMultipleRemoteVideoEnable OBJECT-TYPE Blade multiple remote video sessions enablement status policy. A maximum users can access the video of the same blade from remote console when set to enabled. If it is disabled, only one user can access the video from remote control. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladePolicyAutoPowerOn OBJECT-TYPE Blade auto-power on policy. - restore: all blades will be powered on which were previously on. - auto: all blades will automatically be powered on when power is applied to the chassis. - manual: all blades will be left off until manually powered on by the user. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.7 | INTEGER {restore(1), auto(2), manual(3)} | read-write | mandatory |
| bladePolicyDisconnectionMode OBJECT-TYPE Blade disconnection mode. - noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection - forcedisconnection: If the blade is already serving a maximum number of users, the requester can disconnect any connected user. - accessRequest: If the blade is already serving an user, this one will get an access request from the requester. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.8 | INTEGER {noDisconnection(0), forceDisconnection(1), accessRequest(2)} | read-write | mandatory |
| bladePolicySessionTimeOut OBJECT-TYPE Client session time out in minutes. If there is no remote presence activity, after that time, the session will be closed authomatically. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.9 | INTEGER | read-write | mandatory |
| bladePolicyRequestTimeOut OBJECT-TYPE Client connection request time out in seconds. In case of single session mode, if the requested user does not respond within this timeout, the user request will be accepted authomatically. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.10 | INTEGER | read-write | mandatory |
| bladePolicyRetryTimeOut OBJECT-TYPE Client connection retry time out in seconds. It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to wait and retry to connect after a while. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.11 | INTEGER | read-write | mandatory |
| bladePolicySessionLostTimeOut OBJECT-TYPE Client session lost in minutes. Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the client machine loses a network connection. | 1.3.6.1.4.1.2.3.51.2.22.1.4.2.12 | INTEGER | read-write | mandatory |
| bladeMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.5 | |||
| bladeSystemStatusTable OBJECT-TYPE Table of blade status information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1 | not-accessible | mandatory | |
| bladeSystemStatusEntry OBJECT-TYPE Blade system status entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1 | not-accessible | mandatory | |
| bladeStatusIndex OBJECT-TYPE Blade system status index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1 | INTEGER | read-only | mandatory |
| bladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)} | read-only | mandatory |
| bladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6 | OCTET STRING | read-only | mandatory |
| bladeRemotePowerEnable OBJECT-TYPE Remote power state for the blade. 0x01 indicates enabled. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| bladeRemoteMediaTrayEnable OBJECT-TYPE Remote Media Tray state for the blade. 0x01 indicates enabled. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.8 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| bladeRemoteKVMEnable OBJECT-TYPE Remote keyboard/video/monitor state for the blade. 0x01 indicates enabled. Note that some types of blades don't support KVM | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.9 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| bladeConnectionType OBJECT-TYPE Connection type of the expansion card number one. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeOwnsKVM OBJECT-TYPE Indicates whether the MM owns the KVM. 0 = false, 1 = true. Note that some types of blades don't support KVM | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.11 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeOwnsMediaTray OBJECT-TYPE Indicates whether the blade owns the Media Tray. 0 = false, 1 = true. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.12 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeRemoteWakeOnLanEnable OBJECT-TYPE Remote wake on LAN state for the blade. 0x01 indicates enabled. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-only | mandatory |
| bladeServerExpansion OBJECT-TYPE This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bladeWidth OBJECT-TYPE The width of the blade including any supplement blade attached to it | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15 | INTEGER | read-only | mandatory |
| bladeSupportCapacityOnDemand OBJECT-TYPE This shows whether this blade support Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.16 | INTEGER {no(0), yes(1)} | read-only | deprecated |
| bladeServerExpansion2 OBJECT-TYPE This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| bladecKVMStatus OBJECT-TYPE This shows whether this blade has a concurrent keyboard, video, and mouse (cKVM) card installed and the status of cKVM on the blade. Not present: A cKVM card is not installed. Not ready: A cKVM card is installed but is not functional. Ready: A cKVM card is installed and is functional, with no cKVM session in progress. Active: A cKVM card is installed and is functional, with a cKVM session currently in progress. Disabled: A cKVM card is not enabled on this blade. Not available: A cKVM card is installed but the status is not available. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.21 | INTEGER {notPresent(0), notReady(1), ready(2), active(3), disabled(4), notAvailable(255)} | read-only | mandatory |
| bladeConnectionType2 OBJECT-TYPE Connection type of the expansion card number 2. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType3 OBJECT-TYPE Connection type of the expansion card number 3. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType4 OBJECT-TYPE Connection type of the expansion card number 4. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeConnectionType5 OBJECT-TYPE Connection type of the expansion card number 5. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)} | read-only | mandatory |
| bladeHighSpeedConnectionType OBJECT-TYPE Connection type of the high speed expansion card number 1. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41 | INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6), infinibandPassThrough(7)} | read-only | mandatory |
| bladeIOCompatibility OBJECT-TYPE I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51 | OCTET STRING | read-only | mandatory |
| bladeInventoryReady OBJECT-TYPE When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period. | 1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52 | INTEGER {notReady(0), ready(1)} | read-only | mandatory |
| bladeHealthSummaryTable OBJECT-TYPE Table of blade health summary information. Contains information about the overall blade health status. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2 | not-accessible | mandatory | |
| bladeHealthSummaryEntry OBJECT-TYPE Blade health summary entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1 | not-accessible | mandatory | |
| bladeHealthSummaryIndex OBJECT-TYPE Blade health summary index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1 | INTEGER | read-only | mandatory |
| bladeHealthSummaryBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeHealthSummarySeverity OBJECT-TYPE System health summary severity. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3 | OCTET STRING | read-only | mandatory |
| bladeHealthSummaryDescription OBJECT-TYPE System health summary description. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4 | OCTET STRING | read-only | mandatory |
| bladeHealthSummaryDateTime OBJECT-TYPE System health summary date time. | 1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeTemperaturesTable OBJECT-TYPE Table of blade temperatures information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3 | not-accessible | mandatory | |
| bladeTemperaturesEntry OBJECT-TYPE Blade temperatures table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1 | not-accessible | mandatory | |
| temperatureIndex OBJECT-TYPE Blade temperatures table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1 | INTEGER | read-only | mandatory |
| temperatureBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| temperatureBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| temperatureBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5 | OCTET STRING | read-only | mandatory |
| temperatureCPU1 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6 | OCTET STRING | read-only | mandatory |
| temperatureCPU2 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7 | OCTET STRING | read-only | mandatory |
| temperatureCPU3 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8 | OCTET STRING | read-only | mandatory |
| temperatureCPU4 OBJECT-TYPE The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9 | OCTET STRING | read-only | mandatory |
| temperatureDASD1 OBJECT-TYPE The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10 | OCTET STRING | read-only | mandatory |
| bladeSensorTempCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12 | OCTET STRING | read-only | mandatory |
| bladeSensor2Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13 | OCTET STRING | read-only | mandatory |
| bladeSensor3Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14 | OCTET STRING | read-only | mandatory |
| bladeSensor4Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15 | OCTET STRING | read-only | mandatory |
| bladeSensor5Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16 | OCTET STRING | read-only | mandatory |
| bladeSensor6Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17 | OCTET STRING | read-only | mandatory |
| bladeSensor7Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18 | OCTET STRING | read-only | mandatory |
| bladeSensor8Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19 | OCTET STRING | read-only | mandatory |
| bladeSensor9Temp OBJECT-TYPE Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20 | OCTET STRING | read-only | mandatory |
| bladeTemperatureThresholdsTable OBJECT-TYPE Table of blade temperature thresholds information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4 | not-accessible | mandatory | |
| bladeTemperatureThresholdsEntry OBJECT-TYPE Blade temperature thresholds table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1 | not-accessible | mandatory | |
| temperatureThresholdIndex OBJECT-TYPE Blade temperature threshold table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 | INTEGER | read-only | mandatory |
| temperatureThresholdBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| temperatureThresholdBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureThresholdBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| temperatureThresholdBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5 | OCTET STRING | read-only | mandatory |
| temperatureCPU1HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 | OCTET STRING | read-only | mandatory |
| temperatureCPU1Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 | OCTET STRING | read-only | mandatory |
| temperatureCPU1WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 | OCTET STRING | read-only | mandatory |
| temperatureCPU2HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9 | OCTET STRING | read-only | mandatory |
| temperatureCPU2Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 | OCTET STRING | read-only | mandatory |
| temperatureCPU2WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 | OCTET STRING | read-only | mandatory |
| temperatureCPU3HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 | OCTET STRING | read-only | mandatory |
| temperatureCPU3Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 | OCTET STRING | read-only | mandatory |
| temperatureCPU3WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 | OCTET STRING | read-only | mandatory |
| temperatureCPU4HardShutdown OBJECT-TYPE The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 | OCTET STRING | read-only | mandatory |
| temperatureCPU4Warning OBJECT-TYPE The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 | OCTET STRING | read-only | mandatory |
| temperatureCPU4WarningReset OBJECT-TYPE The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 | OCTET STRING | read-only | mandatory |
| temperatureDASD1HardShutdown OBJECT-TYPE The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 | OCTET STRING | read-only | mandatory |
| temperatureDASD1Warning OBJECT-TYPE The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 | OCTET STRING | read-only | mandatory |
| temperatureDASD1WarningReset OBJECT-TYPE The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 | OCTET STRING | read-only | mandatory |
| bladeTempThresholdSensorCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 | INTEGER {false(0), true(1)} | read-only | mandatory |
| temperatureSensor1HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 | OCTET STRING | read-only | mandatory |
| temperatureSensor1Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 | OCTET STRING | read-only | mandatory |
| temperatureSensor1WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 | OCTET STRING | read-only | mandatory |
| temperatureSensor2HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 | OCTET STRING | read-only | mandatory |
| temperatureSensor2Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 | OCTET STRING | read-only | mandatory |
| temperatureSensor2WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 | OCTET STRING | read-only | mandatory |
| temperatureSensor3HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 | OCTET STRING | read-only | mandatory |
| temperatureSensor3Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 | OCTET STRING | read-only | mandatory |
| temperatureSensor3WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 | OCTET STRING | read-only | mandatory |
| temperatureSensor4HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 | OCTET STRING | read-only | mandatory |
| temperatureSensor4Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 | OCTET STRING | read-only | mandatory |
| temperatureSensor4WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 | OCTET STRING | read-only | mandatory |
| temperatureSensor5HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 | OCTET STRING | read-only | mandatory |
| temperatureSensor5Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 | OCTET STRING | read-only | mandatory |
| temperatureSensor5WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 | OCTET STRING | read-only | mandatory |
| temperatureSensor6HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 | OCTET STRING | read-only | mandatory |
| temperatureSensor6Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 | OCTET STRING | read-only | mandatory |
| temperatureSensor6WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 | OCTET STRING | read-only | mandatory |
| temperatureSensor7HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40 | OCTET STRING | read-only | mandatory |
| temperatureSensor7Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41 | OCTET STRING | read-only | mandatory |
| temperatureSensor7WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42 | OCTET STRING | read-only | mandatory |
| temperatureSensor8HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43 | OCTET STRING | read-only | mandatory |
| temperatureSensor8Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44 | OCTET STRING | read-only | mandatory |
| temperatureSensor8WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45 | OCTET STRING | read-only | mandatory |
| temperatureSensor9HardShutdown OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46 | OCTET STRING | read-only | mandatory |
| temperatureSensor9Warning OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47 | OCTET STRING | read-only | mandatory |
| temperatureSensor9WarningReset OBJECT-TYPE The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48 | OCTET STRING | read-only | mandatory |
| bladeVoltagesTable OBJECT-TYPE Table of blade voltages information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5 | not-accessible | mandatory | |
| bladeVoltagesEntry OBJECT-TYPE Blade voltages table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1 | not-accessible | mandatory | |
| voltageIndex OBJECT-TYPE Blade voltages table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1 | INTEGER | read-only | mandatory |
| voltageBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| voltageBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| voltageBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| voltageBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5 | OCTET STRING | read-only | mandatory |
| bladePlus5Volt OBJECT-TYPE +5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3Volt OBJECT-TYPE +3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7 | OCTET STRING | read-only | mandatory |
| bladePlus12Volt OBJECT-TYPE +12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5Volt OBJECT-TYPE +2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5Volt OBJECT-TYPE +1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25Volt OBJECT-TYPE +1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12 | OCTET STRING | read-only | mandatory |
| bladeVRM1Volt OBJECT-TYPE VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13 | OCTET STRING | read-only | mandatory |
| bladeSensorVoltCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15 | OCTET STRING | read-only | mandatory |
| bladeSensor2Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16 | OCTET STRING | read-only | mandatory |
| bladeSensor3Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17 | OCTET STRING | read-only | mandatory |
| bladeSensor4Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18 | OCTET STRING | read-only | mandatory |
| bladeSensor5Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19 | OCTET STRING | read-only | mandatory |
| bladeSensor6Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20 | OCTET STRING | read-only | mandatory |
| bladeSensor7Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21 | OCTET STRING | read-only | mandatory |
| bladeSensor8Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22 | OCTET STRING | read-only | mandatory |
| bladeSensor9Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23 | OCTET STRING | read-only | mandatory |
| bladeSensor10Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24 | OCTET STRING | read-only | mandatory |
| bladeSensor11Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25 | OCTET STRING | read-only | mandatory |
| bladeSensor12Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26 | OCTET STRING | read-only | mandatory |
| bladeSensor13Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27 | OCTET STRING | read-only | mandatory |
| bladeSensor14Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28 | OCTET STRING | read-only | mandatory |
| bladeSensor15Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29 | OCTET STRING | read-only | mandatory |
| bladeSensor16Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30 | OCTET STRING | read-only | mandatory |
| bladeSensor17Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31 | OCTET STRING | read-only | mandatory |
| bladeSensor18Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32 | OCTET STRING | read-only | mandatory |
| bladeSensor19Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33 | OCTET STRING | read-only | mandatory |
| bladeSensor20Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34 | OCTET STRING | read-only | mandatory |
| bladeSensor21Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35 | OCTET STRING | read-only | mandatory |
| bladeSensor22Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36 | OCTET STRING | read-only | mandatory |
| bladeSensor23Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37 | OCTET STRING | read-only | mandatory |
| bladeSensor24Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38 | OCTET STRING | read-only | mandatory |
| bladeSensor25Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39 | OCTET STRING | read-only | mandatory |
| bladeSensor26Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40 | OCTET STRING | read-only | mandatory |
| bladeSensor27Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41 | OCTET STRING | read-only | mandatory |
| bladeSensor28Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42 | OCTET STRING | read-only | mandatory |
| bladeSensor29Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43 | OCTET STRING | read-only | mandatory |
| bladeSensor30Volt OBJECT-TYPE Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44 | OCTET STRING | read-only | mandatory |
| bladeVoltageThresholdsTable OBJECT-TYPE Table of blade VoltageThresholds information. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6 | not-accessible | mandatory | |
| bladeVoltageThresholdsEntry OBJECT-TYPE Blade voltage thresholds table entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1 | not-accessible | mandatory | |
| voltageThresholdIndex OBJECT-TYPE Blade voltage thresholds table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1 | INTEGER | read-only | mandatory |
| voltageThresholdBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| voltageThresholdBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| voltageThresholdBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| voltageThresholdBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5 | OCTET STRING | read-write | mandatory |
| bladePlus5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6 | OCTET STRING | read-only | mandatory |
| bladePlus5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8 | OCTET STRING | read-only | mandatory |
| bladePlus3pt3VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9 | OCTET STRING | read-only | mandatory |
| bladePlus12VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10 | OCTET STRING | read-only | mandatory |
| bladePlus12VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14 | OCTET STRING | read-only | mandatory |
| bladePlus2pt5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16 | OCTET STRING | read-only | mandatory |
| bladePlus1pt5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25VoltHighWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18 | OCTET STRING | read-only | mandatory |
| bladePlus1pt25VoltLowWarning OBJECT-TYPE Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19 | OCTET STRING | read-only | mandatory |
| bladeVoltThresholdSensorCapability OBJECT-TYPE Indicates whether the server blade is IPMI capable or not. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bladeSensor1VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23 | OCTET STRING | read-only | mandatory |
| bladeSensor1VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24 | OCTET STRING | read-only | mandatory |
| bladeSensor2VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25 | OCTET STRING | read-only | mandatory |
| bladeSensor2VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26 | OCTET STRING | read-only | mandatory |
| bladeSensor3VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27 | OCTET STRING | read-only | mandatory |
| bladeSensor3VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28 | OCTET STRING | read-only | mandatory |
| bladeSensor4VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29 | OCTET STRING | read-only | mandatory |
| bladeSensor4VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30 | OCTET STRING | read-only | mandatory |
| bladeSensor5VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31 | OCTET STRING | read-only | mandatory |
| bladeSensor5VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32 | OCTET STRING | read-only | mandatory |
| bladeSensor6VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33 | OCTET STRING | read-only | mandatory |
| bladeSensor6VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34 | OCTET STRING | read-only | mandatory |
| bladeSensor7VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35 | OCTET STRING | read-only | mandatory |
| bladeSensor7VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36 | OCTET STRING | read-only | mandatory |
| bladeSensor8VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37 | OCTET STRING | read-only | mandatory |
| bladeSensor8VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38 | OCTET STRING | read-only | mandatory |
| bladeSensor9VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39 | OCTET STRING | read-only | mandatory |
| bladeSensor9VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40 | OCTET STRING | read-only | mandatory |
| bladeSensor10VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41 | OCTET STRING | read-only | mandatory |
| bladeSensor10VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42 | OCTET STRING | read-only | mandatory |
| bladeSensor11VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43 | OCTET STRING | read-only | mandatory |
| bladeSensor11VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44 | OCTET STRING | read-only | mandatory |
| bladeSensor12VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45 | OCTET STRING | read-only | mandatory |
| bladeSensor12VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46 | OCTET STRING | read-only | mandatory |
| bladeSensor13VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47 | OCTET STRING | read-only | mandatory |
| bladeSensor13VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48 | OCTET STRING | read-only | mandatory |
| bladeSensor14VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49 | OCTET STRING | read-only | mandatory |
| bladeSensor14VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50 | OCTET STRING | read-only | mandatory |
| bladeSensor15VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51 | OCTET STRING | read-only | mandatory |
| bladeSensor15VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52 | OCTET STRING | read-only | mandatory |
| bladeSensor16VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53 | OCTET STRING | read-only | mandatory |
| bladeSensor16VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54 | OCTET STRING | read-only | mandatory |
| bladeSensor17VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55 | OCTET STRING | read-only | mandatory |
| bladeSensor17VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56 | OCTET STRING | read-only | mandatory |
| bladeSensor18VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57 | OCTET STRING | read-only | mandatory |
| bladeSensor18VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58 | OCTET STRING | read-only | mandatory |
| bladeSensor19VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59 | OCTET STRING | read-only | mandatory |
| bladeSensor19VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60 | OCTET STRING | read-only | mandatory |
| bladeSensor20VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61 | OCTET STRING | read-only | mandatory |
| bladeSensor20VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62 | OCTET STRING | read-only | mandatory |
| bladeSensor21VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63 | OCTET STRING | read-only | mandatory |
| bladeSensor21VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64 | OCTET STRING | read-only | mandatory |
| bladeSensor22VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65 | OCTET STRING | read-only | mandatory |
| bladeSensor22VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66 | OCTET STRING | read-only | mandatory |
| bladeSensor23VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67 | OCTET STRING | read-only | mandatory |
| bladeSensor23VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68 | OCTET STRING | read-only | mandatory |
| bladeSensor24VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69 | OCTET STRING | read-only | mandatory |
| bladeSensor24VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70 | OCTET STRING | read-only | mandatory |
| bladeSensor25VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71 | OCTET STRING | read-only | mandatory |
| bladeSensor25VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72 | OCTET STRING | read-only | mandatory |
| bladeSensor26VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73 | OCTET STRING | read-only | mandatory |
| bladeSensor26VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74 | OCTET STRING | read-only | mandatory |
| bladeSensor27VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75 | OCTET STRING | read-only | mandatory |
| bladeSensor27VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76 | OCTET STRING | read-only | mandatory |
| bladeSensor28VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77 | OCTET STRING | read-only | mandatory |
| bladeSensor28VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78 | OCTET STRING | read-only | mandatory |
| bladeSensor29VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79 | OCTET STRING | read-only | mandatory |
| bladeSensor29VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80 | OCTET STRING | read-only | mandatory |
| bladeSensor30VoltHighWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81 | OCTET STRING | read-only | mandatory |
| bladeSensor30VoltLowWarning OBJECT-TYPE Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off. | 1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82 | OCTET STRING | read-only | mandatory |
| bladeIOCompatibilityTable OBJECT-TYPE Table of IO Compatibility status for the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7 | not-accessible | mandatory | |
| bladeIOCompatibilityEntry OBJECT-TYPE Blade IO Compatibility Status entry | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1 | not-accessible | mandatory | |
| bladeIOCompatibilityIndex OBJECT-TYPE The blade I/O compatibility table index. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.1 | INTEGER | read-only | mandatory |
| bladeIOCompatibilityBladeId OBJECT-TYPE The blade numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeIOCompatibilityBayNumber OBJECT-TYPE The Bay number of the blade or expension card. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.3 | INTEGER | read-only | mandatory |
| bladeIOCompatibilityModuleBay OBJECT-TYPE The modules (each one specified by module type and bay number) that the blade can communicate with over the midplane networking fabric (i.e. a physical path exists between the blade and this module, and hardware exists on the blade to communicate with this module). | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.4 | OCTET STRING | read-only | mandatory |
| bladeIOCompatibilityModulePower OBJECT-TYPE The power state of the module specified in bladeIOCompatibilityModuleBay. n/a if module not installed. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.5 | OCTET STRING | read-only | mandatory |
| bladeIOCompatibilityModuleFabricType OBJECT-TYPE The fabric type of the module specified in bladeIOCompatibilityModuleBay. | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.6 | OCTET STRING | read-only | mandatory |
| bladeIOCompatibilityFabricOnBlade OBJECT-TYPE The fabric type for this channel on the blade (may be onboard fabric or an expansion card). | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.7 | OCTET STRING | read-only | mandatory |
| bladeIOCompatibilityStatus OBJECT-TYPE The compatibility status between the blade and the module specified in bladeIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the blade. n/a: (Not applicable) The module specified in bladeIOCompatibilityModuleBay is a bridge, so the blade port cannot connect to it. Attention: The module specified in bladeIOCompatibilityModuleBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in bladeIOCompatibilityModuleBay is of unknown type Unknown fabric type on the blade | 1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.8 | OCTET STRING | read-only | mandatory |
| bladePowerRestart OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.6 | |||
| bladePowerRestartTable OBJECT-TYPE Table of blade remote power control information. Contains power on/off enablement status for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1 | not-accessible | mandatory | |
| bladePowerRestartEntry OBJECT-TYPE Blade power restart table entry | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1 | not-accessible | mandatory | |
| powerRestartIndex OBJECT-TYPE Blade power restart table index. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1 | INTEGER | read-only | mandatory |
| powerRestartBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| powerRestartBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| powerRestartBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) value is returned. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| powerRestartBladeHealthState OBJECT-TYPE The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5 | INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)} | read-only | mandatory |
| powerRestartBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6 | OCTET STRING | read-only | mandatory |
| powerOnOffBlade OBJECT-TYPE Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s) | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7 | INTEGER {off(0), on(1), softoff(2)} | read-write | mandatory |
| restartBlade OBJECT-TYPE Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeSMP OBJECT-TYPE Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeNMI OBJECT-TYPE Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeClearNVRAM OBJECT-TYPE Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeInvokeDiags OBJECT-TYPE Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeInvokeDiagsFromDefaultBootList OBJECT-TYPE Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeToSMSBootMenu OBJECT-TYPE Restart a blade to SMS boot menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14 | INTEGER {execute(1)} | read-write | mandatory |
| restartBladeToUEFIMenu OBJECT-TYPE Restart a blade to UEFI setup menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15 | INTEGER {execute(1)} | read-write | mandatory |
| bladeConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.7 | |||
| bladeConfigurationTable OBJECT-TYPE Table of blade remote power control information. Contains power on/off enablement status for each blade. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1 | not-accessible | mandatory | |
| bladeConfigurationEntry OBJECT-TYPE Blade configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1 | not-accessible | mandatory | |
| configurationIndex OBJECT-TYPE Blade configuration table index. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1 | INTEGER | read-only | mandatory |
| configurationBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| configurationBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| configurationBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| configurationBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5 | OCTET STRING | read-write | mandatory |
| configurationBladecKVM OBJECT-TYPE Enable or disable the concurrent KVM function on specified blade. If concurrent KVM is not supported by the blade, it displays 'notPresent' and the concurrent KVM functionality can not be enabled or disabled. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.6 | INTEGER {disable(0), enable(1), notPresent(2)} | read-write | mandatory |
| configurationBladeActiveBootMode OBJECT-TYPE Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-only | mandatory |
| configurationBladePendingBootMode OBJECT-TYPE Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible. | 1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8 | INTEGER {temporary(1), permanent(2), notApplicable(255)} | read-write | mandatory |
| bladePowerManagementPolicy OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.7.2 | |||
| powerdomain1Oversubscription OBJECT-TYPE Power Management Policy settings for power domain 1. | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.1 | INTEGER {not-allowed(0), recoverable(1), non-recoverable(2)} | read-write | mandatory |
| powerdomain2Oversubscription OBJECT-TYPE Power Management Policy settings for power domain 2. | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.2 | INTEGER {not-allowed(0), recoverable(1), non-recoverable(2)} | read-write | mandatory |
| acousticMode OBJECT-TYPE Acoustic mode setting for thermal conditions | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| nebsMode OBJECT-TYPE NEBS (Network Equipment-Building System) mode setting for thermal conditions. NOTE: This MIB object is for BladeCenter T, HT and TR only. | 1.3.6.1.4.1.2.3.51.2.22.1.7.2.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladecKVMEnableDisable OBJECT-TYPE Enable or disable cKVM function on all server blades. | 1.3.6.1.4.1.2.3.51.2.22.1.7.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPAddrRangeStart OBJECT-TYPE This field is used to configure the start of the IP address range for the blade system management processors on the blades. These addresses are used on the internal management network between the MM and the blade BSMPs. For example the value of 10.10.10.1 means the BSMP on the blade in bay 1 will have IP address 10.10.10.1, the BSMP on the blade in bay 2 will have IP address 10.10.10.2 and so on. This field is deprecated and no longer supported. An attempt to SET this object will be rejected, and any query will always return 0.0.0.0. Refer to the bladeManagementNetworkInfoTable for the new objects providing this information. | 1.3.6.1.4.1.2.3.51.2.22.1.8 | IpAddress | read-only | deprecated |
| bladeCapacityOnDemand OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.9 | |||
| bladeCapacityOnDemandTable OBJECT-TYPE Table of COD blade. NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.9.1 | not-accessible | deprecated | |
| bladeCapacityOnDemandEntry OBJECT-TYPE Blade COD table entry NOTE: This table is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1 | not-accessible | deprecated | |
| bladeCapacityOnDemandIndex OBJECT-TYPE Blade configuration table index. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.1 | INTEGER | read-only | deprecated |
| bladeCapacityOnDemandBladeName OBJECT-TYPE The name of the blade as a null terminated string. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.2 | OCTET STRING | read-only | deprecated |
| bladeCapacityOnDemandState OBJECT-TYPE The state of Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported. | 1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.3 | INTEGER {none(0), standby(1), active(2)} | read-write | deprecated |
| bladeBootCountPowerOnTime OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.10 | |||
| bladeBootCountPowerOnTimeTable OBJECT-TYPE Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1 | not-accessible | mandatory | |
| bladeBootCountPowerOnTimeEntry OBJECT-TYPE The number of boots for the blade and the number of seconds the blade has been powered on. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1 | not-accessible | mandatory | |
| bootCountPowerOnTimeBladeIndex OBJECT-TYPE Blade boot count/Power On Time table index. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1 | INTEGER | read-only | mandatory |
| bootCountPowerOnTimeBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bootCountPowerOnTimeBoots OBJECT-TYPE Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3 | INTEGER | read-write | mandatory |
| bootCountPowerOnTimeSecs OBJECT-TYPE Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero. | 1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4 | INTEGER | read-write | mandatory |
| bladeVlanId OBJECT-TYPE This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095. | 1.3.6.1.4.1.2.3.51.2.22.1.11 | INTEGER | read-write | mandatory |
| bladeNetworkConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.12 | |||
| bladeNetworkInterfaceTable OBJECT-TYPE Table of all blades' network interfaces. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2 | not-accessible | mandatory | |
| bladeNetworkInterfaceEntry OBJECT-TYPE Blade configuration table entry | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1 | not-accessible | mandatory | |
| bladeNetworkInterfaceIndex OBJECT-TYPE Blade Network Interface Table index. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.1 | INTEGER | read-only | mandatory |
| bladeNetworkInterfaceBayNumber OBJECT-TYPE The bay number of the main server blade that supports network interface management | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.2 | OCTET STRING | read-only | mandatory |
| bladeNetworkInterfaceNumber OBJECT-TYPE Indicates which network interface on the blade System Management Processor is be read or writen | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.3 | INTEGER | read-only | mandatory |
| bladeNetworkInterfaceType OBJECT-TYPE Indicates blade network interface type. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.4 | INTEGER {private(1), public(2)} | read-only | mandatory |
| bladeNetworkInterfaceLabel OBJECT-TYPE Show string label that identifies the interface. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.5 | OCTET STRING | read-only | mandatory |
| bladeNetworkInterfaceIPAddr OBJECT-TYPE Show/modify current IP address of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the IP address be pushed down to blade System Management Processor | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.6 | IpAddress | read-write | mandatory |
| bladeNetworkInterfaceSubnetMask OBJECT-TYPE Show or modifie current subnet mask of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the SunnetMask be pushed down to blade System Management Processor | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.7 | IpAddress | read-write | mandatory |
| bladeNetworkInterfaceGatewayAddr OBJECT-TYPE Show or modify current IP gateway of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the Gateway address be pushed down to blade System Management Processor | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.8 | IpAddress | read-write | mandatory |
| bladeNetworkInterfaceVlanId OBJECT-TYPE This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.9 | INTEGER | read-write | mandatory |
| bladeNetworkInterfaceVlanEnable OBJECT-TYPE This object is no longer supported and will always be 0 | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.10 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-only | deprecated |
| bladeNetworkInterfaceEnable OBJECT-TYPE Disabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations. If this network interface doesn't support enabled/disabled, show 'notApplicable(255)' | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.11 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bladeNetworkInterfaceDHCPEnable OBJECT-TYPE IP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic. If this network interface doesn't support DHCP, show 'notApplicable(255)' | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.12 | INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2), notApplicable(255)} | read-write | mandatory |
| bladeNetworkInterfaceMACAddr OBJECT-TYPE Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable' | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.13 | OCTET STRING | read-only | mandatory |
| bladeNetworkInterfaceAssignedSwitch OBJECT-TYPE This field allows you to select an I/O Module to use for management traffic to the blade. NOTE: This field is only supported for eth1 of blade. NOTE: You may only specify ethernet switches to this field. | 1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.14 | INTEGER {notAssigned(0), module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10), notApplicable(255)} | read-write | mandatory |
| bladeIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.12.10 | |||
| bladeIPv6ConfigTable OBJECT-TYPE A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1 | not-accessible | mandatory | |
| bladeIPv6ConfigEntry OBJECT-TYPE IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1 | not-accessible | mandatory | |
| bladeIPv6ConfigIndex OBJECT-TYPE The blade's slot number | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1 | INTEGER | read-only | mandatory |
| bladeIPv6ConfigPortIndex OBJECT-TYPE The physical port number of the given entry | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2 | INTEGER | read-only | mandatory |
| bladeIPv6ConfigEnabled OBJECT-TYPE Enables/Disables IPv6 support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6ConfigStatic OBJECT-TYPE Enables/Disables IPv6 static configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeDHCPv6ConfigEnabled OBJECT-TYPE Enables/Disables DHCPv6 address configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6ConfigStatelessEnabled OBJECT-TYPE Enables/Disables IPv6 stateless auto-configuration support on the blade. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| bladeIPv6AddressTable OBJECT-TYPE A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2 | not-accessible | mandatory | |
| bladeIPv6AddressEntry OBJECT-TYPE The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1 | not-accessible | mandatory | |
| bladeIPv6AddressIndex OBJECT-TYPE The blade's slot number. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1 | INTEGER | read-only | mandatory |
| bladeIPv6AddressPortIndex OBJECT-TYPE The blade's physical port number for the given entry. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2 | INTEGER | read-only | mandatory |
| bladeIPv6AddressEntryIndex OBJECT-TYPE The blade's address entry index. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3 | INTEGER | read-only | mandatory |
| bladeIPv6AddressType OBJECT-TYPE The address type. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4 | INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)} | read-only | mandatory |
| bladeIPv6Address OBJECT-TYPE The assigned IPv6 address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5 | InetAddressIPv6 | read-write | mandatory |
| bladeIPv6AddressPrefixLen OBJECT-TYPE The prefix length for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6 | INTEGER (1..128) | read-write | mandatory |
| bladeIPv6AddressDefaultRoute OBJECT-TYPE The default route used for the given address. Note: 'write' is for static ipv6 only. | 1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7 | InetAddressIPv6 | read-write | mandatory |
| bladeBayDataTable OBJECT-TYPE Table of blade bay data (BBD) information. | 1.3.6.1.4.1.2.3.51.2.22.1.13 | not-accessible | mandatory | |
| bladeBayDataEntry OBJECT-TYPE Blade bay data (BBD) table entry. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1 | not-accessible | mandatory | |
| bayDataIndex OBJECT-TYPE Blade bay data (BBD) table index. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.1 | INTEGER | read-only | mandatory |
| bayDataBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bayDataBladeExists OBJECT-TYPE Indicates whether the server blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| bayDataBladePowerState OBJECT-TYPE Indicates the power state of the blade specified. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4)} | read-only | mandatory |
| bayDataBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.5 | OCTET STRING | read-only | mandatory |
| bayData OBJECT-TYPE A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.6 | OCTET STRING | read-write | mandatory |
| bayDataBladeStatus OBJECT-TYPE This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD. | 1.3.6.1.4.1.2.3.51.2.22.1.13.1.7 | INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)} | read-only | mandatory |
| bladeSPEthOverUSBInterface OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.14 | |||
| spEthOverUSBInterfaceTable OBJECT-TYPE Table of blade Service Processor's Ethernet over USB interface. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1 | not-accessible | mandatory | |
| spEthOverUSBInterfaceEntry OBJECT-TYPE Blade Service Processor's Ethernet over USB interface entry. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1 | not-accessible | mandatory | |
| spEthOverUSBInterfaceIndex OBJECT-TYPE Service Processor's Ethernet over USB interface table index. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1 | INTEGER | read-only | mandatory |
| spEthOverUSBInterfaceBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2 | OCTET STRING | read-only | mandatory |
| spEthOverUSBInterfaceBladeExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| spEthOverUSBInterfaceBladeName OBJECT-TYPE The name of the blade as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6 | OCTET STRING | read-only | mandatory |
| spEthOverUSBInterfaceEnable OBJECT-TYPE This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect. | 1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9 | INTEGER {disabled(0), enabled(1), notApplicable(255)} | read-write | mandatory |
| bladeManagementNetwork OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.1.15 | |||
| bladeManagementNetworkControlEnable OBJECT-TYPE Globally disable/enable blade management network auto discovery support. | 1.3.6.1.4.1.2.3.51.2.22.1.15.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| bladeManagementNetworkInfoTable OBJECT-TYPE Table of blade management network information. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2 | not-accessible | mandatory | |
| bladeManagementNetworkInfoEntry OBJECT-TYPE Blade management network information entry. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1 | not-accessible | mandatory | |
| bladeManagementNetworkInfoIndex OBJECT-TYPE Blade management network information table index | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.1 | INTEGER | read-only | mandatory |
| bladeManagementNetworkInfoBladeId OBJECT-TYPE The Blade ID. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| bladeManagementNetworkInfoBladeExist OBJECT-TYPE Indicates whether the blade specified exists or not in the chassis. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.3 | INTEGER | read-only | mandatory |
| bladeManagementNetworkInfoBladeSupport OBJECT-TYPE Indicates whether the blade supports the management network auto discovery capability or not. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.4 | INTEGER | read-only | mandatory |
| bladeManagementNetworkInfoPathStatus OBJECT-TYPE Indicates the status of the management network for this blade. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.5 | INTEGER {down(0), up(1)} | read-only | mandatory |
| bladeManagementNetworkInfoBladeIPAddr OBJECT-TYPE Indicates the blade system management processor IPv4 address. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.6 | IpAddress | read-only | mandatory |
| bladeManagementNetworkInfoBladeMACAddr OBJECT-TYPE Indicates the blade system management processor MAC address. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.7 | OCTET STRING | read-only | mandatory |
| bladeManagementNetworkInfoSwitchId OBJECT-TYPE Indicates which switch is selected for the blade management network. | 1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.8 | INTEGER | read-only | mandatory |
| switchModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3 | |||
| switchModuleControl OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.1 | |||
| smControlTable OBJECT-TYPE Switch module control table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1 | not-accessible | mandatory | |
| smControlEntry OBJECT-TYPE Switch module control table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1 | not-accessible | mandatory | |
| smControlIndex OBJECT-TYPE Switch module control table index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1 | INTEGER | read-only | mandatory |
| switchModuleControlId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smPostResultsAvailable OBJECT-TYPE Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smPostResultsValue OBJECT-TYPE The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4 | OCTET STRING | read-only | mandatory |
| switchModuleMemDiagEnableDisable OBJECT-TYPE Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5 | INTEGER {enabled(0), disabled(1)} | read-write | mandatory |
| smCfgCtrlEnableDisable OBJECT-TYPE Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smExtEthPortsEnableDisable OBJECT-TYPE Switch module external ethernet ports enabled or disabled. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| switchPingRequest OBJECT-TYPE Sends a ping to a switch module's current IPv4 address. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and IP Configuration is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This object has been deprecated in favor of the new table smPingTable which supports IPv6 and IPv4 addresses. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.8 | INTEGER {execute(1)} | read-write | deprecated |
| smCfgCtrlOnResetEnableDisable OBJECT-TYPE Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9 | INTEGER {enabled(0), disabled(1)} | read-write | mandatory |
| smHealthState OBJECT-TYPE The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| smPMState OBJECT-TYPE The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the AMM. pending - Protected Mode has been activated on the AMM but not yet on the switch module. active - Protected Mode is active on both the switch module and the AMM. attention - Protected Mode is enabled on the switch module but not on the AMM. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16 | INTEGER {disabled(0), pending(1), attention(2), active(3), notApplicable(255)} | read-only | mandatory |
| smPMCtrlEnableDisable OBJECT-TYPE AMM Protected Mode permission for the switch module. disabled - allow AMM to disable Protected Mode Permission for the switch module. enabled - allow AMM to grant Protected Mode Permission for the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| smIOCompatibility OBJECT-TYPE The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to. | 1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18 | OCTET STRING | read-only | mandatory |
| smPingTable OBJECT-TYPE Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.1.2 | not-accessible | mandatory | |
| smPingEntry OBJECT-TYPE Represents a single address that can be pinged | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1 | not-accessible | mandatory | |
| smPingIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1 | INTEGER | read-only | mandatory |
| smPingAddressEntryIndex OBJECT-TYPE The switch module's address entry index | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2 | INTEGER | read-only | mandatory |
| smPingAddress OBJECT-TYPE The switch module's IPv4 or IPv6 address | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3 | OCTET STRING | read-only | mandatory |
| smPingAddressExecute OBJECT-TYPE Pings the given IP address. NOTE: The GET operation for this object is meaningless. | 1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4 | INTEGER {execute(1)} | read-write | mandatory |
| smPowerRestartTable OBJECT-TYPE Switch module power restart table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7 | not-accessible | mandatory | |
| smPowerRestartEntry OBJECT-TYPE Switch module power restart table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1 | not-accessible | mandatory | |
| smPowerRestartIndex OBJECT-TYPE Switch module power restart index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 | INTEGER | read-only | mandatory |
| smPowerRestartId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smSwitchExists OBJECT-TYPE Indicates whether the switch module specified exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smSwitchType OBJECT-TYPE Switch module type. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.4 | INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)} | read-only | mandatory |
| smMACAddress OBJECT-TYPE Switch module MAC address. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 | OCTET STRING | read-only | mandatory |
| smIPAddress OBJECT-TYPE The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 | IpAddress | read-only | mandatory |
| switchModulePowerOnOff OBJECT-TYPE I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. For example, SAS Controller Modules must flush pending I/O before powering off in order to maintain data integrity. The value'shutdownInProgress' can not be used to set. If both SAS Controller Module and SAS Connectivity Module are installed in slot 3 and 4 of BCS chassis, AMM must prevent one of them from powering on otherwise there would be conflict with the Storage Module access and possibly corruption of data. This MIB object can not be set, if AMM grants the I/O Module the Protected Mode permission and module goes into Protected Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7 | INTEGER {poweroff(0), poweron(1), shutdownInProgress(2)} | read-write | mandatory |
| smReset OBJECT-TYPE For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 | INTEGER {execute(1)} | read-write | mandatory |
| smResetToDefault OBJECT-TYPE For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunStdDiag OBJECT-TYPE To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunExtDiag OBJECT-TYPE To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 | INTEGER {execute(1)} | read-write | mandatory |
| smRestartAndRunFullDiag OBJECT-TYPE To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | INTEGER {execute(1)} | read-write | mandatory |
| smSwitchSubType OBJECT-TYPE Switch module subtype. NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.20 | INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)} | read-only | mandatory |
| smSwitchWidth OBJECT-TYPE Switch module width. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21 | INTEGER | read-only | mandatory |
| smManufacturingID OBJECT-TYPE Switch module hardware VPD manufacturing ID. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22 | OCTET STRING | read-only | mandatory |
| smStackingModeState OBJECT-TYPE The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23 | INTEGER {standby(0), member(1), master(2), notApplicable(255)} | read-only | mandatory |
| smStackingModeInfo OBJECT-TYPE A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults. | 1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityTable OBJECT-TYPE Switch module control table. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10 | not-accessible | mandatory | |
| smIOCompatibilityEntry OBJECT-TYPE Switch module IO compatibility table entry | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1 | not-accessible | mandatory | |
| smIOCompatibilityIndex OBJECT-TYPE Switch module IO compatibility index. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1 | INTEGER | read-only | mandatory |
| smIOCompatibilityId OBJECT-TYPE The switch module numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smIOCompatibilityModuleBay OBJECT-TYPE The modules (each one specified by module type and bay number) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module). | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityModulePower OBJECT-TYPE The power state of the module specified in smIOCompatibilityModuleBay. | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityModuleFabricType OBJECT-TYPE The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot). | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5 | OCTET STRING | read-only | mandatory |
| smIOCompatibilityStatus OBJECT-TYPE The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type | 1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6 | OCTET STRING | read-only | mandatory |
| switchModuleConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2 | |||
| switchMgmtNetworkCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1 | |||
| switchCurrentNwCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1 | |||
| smCurrentIPInfoTable OBJECT-TYPE Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1 | not-accessible | mandatory | |
| smCurrentIPInfoEntry OBJECT-TYPE Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1 | not-accessible | mandatory | |
| smCurrentIPInfoIndex OBJECT-TYPE Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1 | INTEGER | read-only | mandatory |
| smCurrentIPInfoId OBJECT-TYPE The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smCurrentIPInfoExists OBJECT-TYPE Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smCurrentIPInfoPowerState OBJECT-TYPE Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. Such as SAS Controller Modules, that must flush pending I/O before powering off in order to maintain data integrity. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4 | INTEGER {off(0), on(1), shutdownInProgress(2)} | read-only | mandatory |
| smCurrentIPAddr OBJECT-TYPE The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6 | IpAddress | read-only | mandatory |
| smCurrentSubnetMask OBJECT-TYPE The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7 | IpAddress | read-only | mandatory |
| smCurrentGateway OBJECT-TYPE The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8 | IpAddress | read-only | mandatory |
| smCurrentIPConfigMethod OBJECT-TYPE The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9 | INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)} | read-only | mandatory |
| switchNewNwCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2 | |||
| smNewIPInfoTable OBJECT-TYPE Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1 | not-accessible | mandatory | |
| smNewIPInfoEntry OBJECT-TYPE Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1 | not-accessible | mandatory | |
| smNewIPInfoIndex OBJECT-TYPE Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1 | INTEGER | read-only | mandatory |
| smNewIPInfoId OBJECT-TYPE The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNewIPInfoExists OBJECT-TYPE Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNewIPInfoPowerState OBJECT-TYPE Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNewIPAddr OBJECT-TYPE The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6 | IpAddress | read-write | mandatory |
| smNewSubnetMask OBJECT-TYPE The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7 | IpAddress | read-write | mandatory |
| smNewGateway OBJECT-TYPE The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8 | IpAddress | read-write | mandatory |
| smNewIPConfigMethod OBJECT-TYPE The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9 | INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)} | read-write | mandatory |
| smNewIPConfigEnableDisable OBJECT-TYPE A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| switchNwProtCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3 | |||
| switchNwProtCfgModOne OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1 | |||
| smNwProtInfoModOneTable OBJECT-TYPE Switch module 1 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1 | not-accessible | mandatory | |
| smNwProtInfoModOneEntry OBJECT-TYPE Switch module 1 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1 | not-accessible | mandatory | |
| smNwProtInfoModOneIndex OBJECT-TYPE Switch module 1 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModOneId OBJECT-TYPE The switch module 1 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModOneExists OBJECT-TYPE Indicates whether the switch module 1 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModOnePowerState OBJECT-TYPE Indicates whether the switch module 1 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModOneProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModOneProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModOneExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModOneIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModOneEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModOneActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModOneReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModTwo OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2 | |||
| smNwProtInfoModTwoTable OBJECT-TYPE Switch module 2 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1 | not-accessible | mandatory | |
| smNwProtInfoModTwoEntry OBJECT-TYPE Switch module 2 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1 | not-accessible | mandatory | |
| smNwProtInfoModTwoIndex OBJECT-TYPE Switch module 2 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModTwoId OBJECT-TYPE The switch module 2 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModTwoExists OBJECT-TYPE Indicates whether the switch module 2 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModTwoPowerState OBJECT-TYPE Indicates whether the switch module 2 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModTwoProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModTwoProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModTwoExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModTwoIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModTwoEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModTwoActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModTwoReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModThree OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3 | |||
| smNwProtInfoModThreeTable OBJECT-TYPE Switch module 3 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1 | not-accessible | mandatory | |
| smNwProtInfoModThreeEntry OBJECT-TYPE Switch module 3 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1 | not-accessible | mandatory | |
| smNwProtInfoModThreeIndex OBJECT-TYPE Switch module 3 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModThreeId OBJECT-TYPE The switch module 3 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModThreeExists OBJECT-TYPE Indicates whether the switch module 3 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModThreePowerState OBJECT-TYPE Indicates whether the switch module 3 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModThreeProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModThreeProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModThreeExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModThreeIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModThreeEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModThreeActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModThreeReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModFour OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4 | |||
| smNwProtInfoModFourTable OBJECT-TYPE Switch module 4 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1 | not-accessible | mandatory | |
| smNwProtInfoModFourEntry OBJECT-TYPE Switch module 3 network protocol (Network Address Translation) configuration information table entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1 | not-accessible | mandatory | |
| smNwProtInfoModFourIndex OBJECT-TYPE Switch module 4 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModFourId OBJECT-TYPE The switch module 4 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModFourExists OBJECT-TYPE Indicates whether the switch module 4 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModFourPowerState OBJECT-TYPE Indicates whether the switch module 4 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModFourProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModFourProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModFourExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModFourIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModFourEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModFourActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModFourReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModFive OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5 | |||
| smNwProtInfoModFiveTable OBJECT-TYPE Switch module 5 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1 | not-accessible | mandatory | |
| smNwProtInfoModFiveEntry OBJECT-TYPE Switch module 5 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1 | not-accessible | mandatory | |
| smNwProtInfoModFiveIndex OBJECT-TYPE Switch module 5 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModFiveId OBJECT-TYPE The switch module 5 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModFiveExists OBJECT-TYPE Indicates whether the switch module 5 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModFivePowerState OBJECT-TYPE Indicates whether the switch module 5 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModFiveProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModFiveProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModFiveExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModFiveIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModFiveEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModFiveActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModFiveReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModSix OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6 | |||
| smNwProtInfoModSixTable OBJECT-TYPE Switch module 6 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1 | not-accessible | mandatory | |
| smNwProtInfoModSixEntry OBJECT-TYPE Switch module 6 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1 | not-accessible | mandatory | |
| smNwProtInfoModSixIndex OBJECT-TYPE Switch module 6 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModSixId OBJECT-TYPE The switch module 6 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModSixExists OBJECT-TYPE Indicates whether the switch module 6 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModSixPowerState OBJECT-TYPE Indicates whether the switch module 6 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModSixProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModSixProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModSixExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModSixIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModSixEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModSixActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModSixReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModSeven OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7 | |||
| smNwProtInfoModSevenTable OBJECT-TYPE Switch module 7 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1 | not-accessible | mandatory | |
| smNwProtInfoModSevenEntry OBJECT-TYPE Switch module 7 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1 | not-accessible | mandatory | |
| smNwProtInfoModSevenIndex OBJECT-TYPE Switch module 7 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModSevenId OBJECT-TYPE The switch module 7 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModSevenExists OBJECT-TYPE Indicates whether the switch module 7 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModSevenPowerState OBJECT-TYPE Indicates whether the switch module 7 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModSevenProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModSevenProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModSevenExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModSevenIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModSevenEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModSevenActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModSevenReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModEight OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8 | |||
| smNwProtInfoModEightTable OBJECT-TYPE Switch module 8 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1 | not-accessible | mandatory | |
| smNwProtInfoModEightEntry OBJECT-TYPE Switch module 8 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1 | not-accessible | mandatory | |
| smNwProtInfoModEightIndex OBJECT-TYPE Switch module 8 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModEightId OBJECT-TYPE The switch module 8 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModEightExists OBJECT-TYPE Indicates whether the switch module 8 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModEightPowerState OBJECT-TYPE Indicates whether the switch module 8 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModEightProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModEightProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModEightExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModEightIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModEightEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModEightActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModEightReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModNine OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9 | |||
| smNwProtInfoModNineTable OBJECT-TYPE Switch module 9 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1 | not-accessible | mandatory | |
| smNwProtInfoModNineEntry OBJECT-TYPE Switch module 9 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1 | not-accessible | mandatory | |
| smNwProtInfoModNineIndex OBJECT-TYPE Switch module 9 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModNineId OBJECT-TYPE The switch module 9 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModNineExists OBJECT-TYPE Indicates whether the switch module 9 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModNinePowerState OBJECT-TYPE Indicates whether the switch module 9 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModNineProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModNineProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModNineExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModNineIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModNineEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModNineActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModNineReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchNwProtCfgModTen OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10 | |||
| smNwProtInfoModTenTable OBJECT-TYPE Switch module 10 network protocol (Network Address Translation) information. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1 | not-accessible | mandatory | |
| smNwProtInfoModTenEntry OBJECT-TYPE Switch module 10 network protocol (Network Address Translation) configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1 | not-accessible | mandatory | |
| smNwProtInfoModTenIndex OBJECT-TYPE Switch module 10 network protocol (Network Address Translation) information index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.1 | INTEGER | read-only | mandatory |
| smNwProtInfoModTenId OBJECT-TYPE The switch module 10 numeric identifier. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.2 | INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)} | read-only | mandatory |
| smNwProtInfoModTenExists OBJECT-TYPE Indicates whether the switch module 10 exists or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| smNwProtInfoModTenPowerState OBJECT-TYPE Indicates whether the switch module 10 is powered on or not. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.4 | INTEGER {off(0), on(1)} | read-only | mandatory |
| smNwProtInfoModTenProtName OBJECT-TYPE Protocol name | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.5 | OCTET STRING | read-write | mandatory |
| smNwProtInfoModTenProtID OBJECT-TYPE Protocol ID | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.6 | INTEGER {tcp(2), udp(3)} | read-write | mandatory |
| smNwProtInfoModTenExtPort OBJECT-TYPE External port | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.7 | INTEGER | read-write | mandatory |
| smNwProtInfoModTenIntPort OBJECT-TYPE Internal port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.8 | INTEGER | read-write | mandatory |
| smNwProtInfoModTenEnable OBJECT-TYPE Enable or disable the protocol entry. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.9 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smNwProtInfoModTenActivate OBJECT-TYPE Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.2 | INTEGER {execute(1)} | read-write | mandatory |
| smNwProtInfoModTenReset OBJECT-TYPE Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.3 | INTEGER {execute(1)} | read-write | mandatory |
| switchIPv6Config OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4 | |||
| smIPv6ConfigTable OBJECT-TYPE A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1 | not-accessible | mandatory | |
| smIPv6ConfigEntry OBJECT-TYPE IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1 | not-accessible | mandatory | |
| smIPv6ConfigIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1 | INTEGER | read-only | mandatory |
| smIPv6ConfigEnabled OBJECT-TYPE Enables/Disables IPv6 support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smIPv6ConfigStatic OBJECT-TYPE Enables/Disables IPv6 static configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smDHCPv6ConfigEnabled OBJECT-TYPE Enables/Disables DHCPv6 address configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smIPv6ConfigStatelessEnabled OBJECT-TYPE Enables/Disables IPv6 stateless auto-configuration support on the switch module. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| smIPv6AddressTable OBJECT-TYPE A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2 | not-accessible | mandatory | |
| smIPv6AddressEntry OBJECT-TYPE The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1 | not-accessible | mandatory | |
| smIPv6AddressIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1 | INTEGER | read-only | mandatory |
| smIPv6AddressEntryIndex OBJECT-TYPE The switch module's address entry index | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2 | INTEGER | read-only | mandatory |
| smIPv6AddressType OBJECT-TYPE The address type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3 | INTEGER {static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5)} | read-only | mandatory |
| smIPv6Address OBJECT-TYPE The assigned IPv6 address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4 | InetAddressIPv6 | read-only | mandatory |
| smIPv6AddressPrefixLen OBJECT-TYPE The prefix length for the given address. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5 | INTEGER | read-only | mandatory |
| smIPv6AddressDefaultRoute OBJECT-TYPE The default route used for the given address | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6 | InetAddressIPv6 | read-only | mandatory |
| smIPv6StaticConfigTable OBJECT-TYPE Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3 | not-accessible | mandatory | |
| smIPv6StaticConfigEntry OBJECT-TYPE The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1 | not-accessible | mandatory | |
| smIPv6StaticIndex OBJECT-TYPE The switch module's slot number | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1 | INTEGER | read-only | mandatory |
| smIPv6StaticAddress OBJECT-TYPE The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2 | InetAddressIPv6 | read-write | mandatory |
| smIPv6StaticAddressPrefixLen OBJECT-TYPE The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3 | INTEGER | read-write | mandatory |
| smIPv6StaticAddressDefaultRoute OBJECT-TYPE The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting. | 1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4 | InetAddressIPv6 | read-write | mandatory |
| switchPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2 | |||
| switchModOnePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1 | |||
| smOnePortCfgTable OBJECT-TYPE Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1 | not-accessible | mandatory | |
| smOnePortCfgEntry OBJECT-TYPE Switch Module 1 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1 | not-accessible | mandatory | |
| smOnePortCfgIndex OBJECT-TYPE Switch Module 1 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1 | INTEGER | read-only | mandatory |
| smOnePortCfgLabel OBJECT-TYPE Switch Module 1 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2 | OCTET STRING | read-only | mandatory |
| smOnePortCfgType OBJECT-TYPE Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smOnePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smOnePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smOnePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6 | OCTET STRING | read-write | mandatory |
| smOnePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7 | OCTET STRING | read-only | mandatory |
| smOnePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8 | OCTET STRING | read-only | mandatory |
| smOnePortCfgMedia OBJECT-TYPE Port media type of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 1. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11 | INTEGER | read-only | mandatory |
| smOnePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12 | INTEGER | read-only | mandatory |
| smOnePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13 | OCTET STRING | read-only | mandatory |
| smOnePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14 | OCTET STRING | read-only | mandatory |
| smOnePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smOnePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModTwoPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2 | |||
| smTwoPortCfgTable OBJECT-TYPE Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1 | not-accessible | mandatory | |
| smTwoPortCfgEntry OBJECT-TYPE Switch Module 2 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1 | not-accessible | mandatory | |
| smTwoPortCfgIndex OBJECT-TYPE Switch Module 2 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1 | INTEGER | read-only | mandatory |
| smTwoPortCfgLabel OBJECT-TYPE Switch Module 2 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgType OBJECT-TYPE Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smTwoPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smTwoPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smTwoPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6 | OCTET STRING | read-write | mandatory |
| smTwoPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgMedia OBJECT-TYPE Port media type of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 2. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11 | INTEGER | read-only | mandatory |
| smTwoPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12 | INTEGER | read-only | mandatory |
| smTwoPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14 | OCTET STRING | read-only | mandatory |
| smTwoPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smTwoPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModThreePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3 | |||
| smThreePortCfgTable OBJECT-TYPE Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1 | not-accessible | mandatory | |
| smThreePortCfgEntry OBJECT-TYPE Switch Module 3 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1 | not-accessible | mandatory | |
| smThreePortCfgIndex OBJECT-TYPE Switch Module 3 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1 | INTEGER | read-only | mandatory |
| smThreePortCfgLabel OBJECT-TYPE Switch Module 3 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2 | OCTET STRING | read-only | mandatory |
| smThreePortCfgType OBJECT-TYPE Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smThreePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smThreePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smThreePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6 | OCTET STRING | read-write | mandatory |
| smThreePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7 | OCTET STRING | read-only | mandatory |
| smThreePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8 | OCTET STRING | read-only | mandatory |
| smThreePortCfgMedia OBJECT-TYPE Port media type of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 3. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11 | INTEGER | read-only | mandatory |
| smThreePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12 | INTEGER | read-only | mandatory |
| smThreePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13 | OCTET STRING | read-only | mandatory |
| smThreePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14 | OCTET STRING | read-only | mandatory |
| smThreePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smThreePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModFourPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4 | |||
| smFourPortCfgTable OBJECT-TYPE Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1 | not-accessible | mandatory | |
| smFourPortCfgEntry OBJECT-TYPE Switch Module 4 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1 | not-accessible | mandatory | |
| smFourPortCfgIndex OBJECT-TYPE Switch Module 4 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1 | INTEGER | read-only | mandatory |
| smFourPortCfgLabel OBJECT-TYPE Switch Module 4 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2 | OCTET STRING | read-only | mandatory |
| smFourPortCfgType OBJECT-TYPE Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smFourPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smFourPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smFourPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6 | OCTET STRING | read-write | mandatory |
| smFourPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7 | OCTET STRING | read-only | mandatory |
| smFourPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8 | OCTET STRING | read-only | mandatory |
| smFourPortCfgMedia OBJECT-TYPE Port media type of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 4. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11 | INTEGER | read-only | mandatory |
| smFourPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12 | INTEGER | read-only | mandatory |
| smFourPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13 | OCTET STRING | read-only | mandatory |
| smFourPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14 | OCTET STRING | read-only | mandatory |
| smFourPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smFourPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModFivePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5 | |||
| smFivePortCfgTable OBJECT-TYPE Switch Module 5 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1 | not-accessible | mandatory | |
| smFivePortCfgEntry OBJECT-TYPE Switch Module 5 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1 | not-accessible | mandatory | |
| smFivePortCfgIndex OBJECT-TYPE Switch Module 5 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.1 | INTEGER | read-only | mandatory |
| smFivePortCfgLabel OBJECT-TYPE Switch Module 5 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.2 | OCTET STRING | read-only | mandatory |
| smFivePortCfgType OBJECT-TYPE Switch Module 5 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smFivePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 5. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smFivePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 5. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smFivePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFivePortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.6 | OCTET STRING | read-write | mandatory |
| smFivePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 5. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.7 | OCTET STRING | read-only | mandatory |
| smFivePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 5. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.8 | OCTET STRING | read-only | mandatory |
| smFivePortCfgMedia OBJECT-TYPE Port media type of Switch Module 5. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smFivePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 5. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smFivePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.11 | INTEGER | read-only | mandatory |
| smFivePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.12 | INTEGER | read-only | mandatory |
| smFivePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.13 | OCTET STRING | read-only | mandatory |
| smFivePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.14 | OCTET STRING | read-only | mandatory |
| smFivePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smFivePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModSixPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6 | |||
| smSixPortCfgTable OBJECT-TYPE Switch Module 6 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1 | not-accessible | mandatory | |
| smSixPortCfgEntry OBJECT-TYPE Switch Module 6 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1 | not-accessible | mandatory | |
| smSixPortCfgIndex OBJECT-TYPE Switch Module 6 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.1 | INTEGER | read-only | mandatory |
| smSixPortCfgLabel OBJECT-TYPE Switch Module 6 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.2 | OCTET STRING | read-only | mandatory |
| smSixPortCfgType OBJECT-TYPE Switch Module 6 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smSixPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smSixPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smSixPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSixPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.6 | OCTET STRING | read-write | mandatory |
| smSixPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.7 | OCTET STRING | read-only | mandatory |
| smSixPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 6. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.8 | OCTET STRING | read-only | mandatory |
| smSixPortCfgMedia OBJECT-TYPE Port media type of Switch Module 6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smSixPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 6. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smSixPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.11 | INTEGER | read-only | mandatory |
| smSixPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.12 | INTEGER | read-only | mandatory |
| smSixPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.13 | OCTET STRING | read-only | mandatory |
| smSixPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.14 | OCTET STRING | read-only | mandatory |
| smSixPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smSixPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModSevenPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7 | |||
| smSevenPortCfgTable OBJECT-TYPE Switch Module 7 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1 | not-accessible | mandatory | |
| smSevenPortCfgEntry OBJECT-TYPE Switch Module 7 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1 | not-accessible | mandatory | |
| smSevenPortCfgIndex OBJECT-TYPE Switch Module 7 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.1 | INTEGER | read-only | mandatory |
| smSevenPortCfgLabel OBJECT-TYPE Switch Module 7 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.2 | OCTET STRING | read-only | mandatory |
| smSevenPortCfgType OBJECT-TYPE Switch Module 7 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smSevenPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 7. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smSevenPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 7. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smSevenPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSevenPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.6 | OCTET STRING | read-write | mandatory |
| smSevenPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 7. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.7 | OCTET STRING | read-only | mandatory |
| smSevenPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 7. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.8 | OCTET STRING | read-only | mandatory |
| smSevenPortCfgMedia OBJECT-TYPE Port media type of Switch Module 7. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smSevenPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 7. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smSevenPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.11 | INTEGER | read-only | mandatory |
| smSevenPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.12 | INTEGER | read-only | mandatory |
| smSevenPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.13 | OCTET STRING | read-only | mandatory |
| smSevenPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.14 | OCTET STRING | read-only | mandatory |
| smSevenPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smSevenPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModEightPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8 | |||
| smEightPortCfgTable OBJECT-TYPE Switch Module 8 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1 | not-accessible | mandatory | |
| smEightPortCfgEntry OBJECT-TYPE Switch Module 8 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1 | not-accessible | mandatory | |
| smEightPortCfgIndex OBJECT-TYPE Switch Module 8 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.1 | INTEGER | read-only | mandatory |
| smEightPortCfgLabel OBJECT-TYPE Switch Module 8 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.2 | OCTET STRING | read-only | mandatory |
| smEightPortCfgType OBJECT-TYPE Switch Module 8 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smEightPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 8. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smEightPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 8. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smEightPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smEightPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.6 | OCTET STRING | read-write | mandatory |
| smEightPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 8. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.7 | OCTET STRING | read-only | mandatory |
| smEightPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 8. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.8 | OCTET STRING | read-only | mandatory |
| smEightPortCfgMedia OBJECT-TYPE Port media type of Switch Module 8. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smEightPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 8. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smEightPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.11 | INTEGER | read-only | mandatory |
| smEightPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.12 | INTEGER | read-only | mandatory |
| smEightPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.13 | OCTET STRING | read-only | mandatory |
| smEightPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.14 | OCTET STRING | read-only | mandatory |
| smEightPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smEightPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModNinePortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9 | |||
| smNinePortCfgTable OBJECT-TYPE Switch Module 9 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1 | not-accessible | mandatory | |
| smNinePortCfgEntry OBJECT-TYPE Switch Module 9 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1 | not-accessible | mandatory | |
| smNinePortCfgIndex OBJECT-TYPE Switch Module 9 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.1 | INTEGER | read-only | mandatory |
| smNinePortCfgLabel OBJECT-TYPE Switch Module 9 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.2 | OCTET STRING | read-only | mandatory |
| smNinePortCfgType OBJECT-TYPE Switch Module 9 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smNinePortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 9. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smNinePortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 9. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smNinePortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smNinePortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.6 | OCTET STRING | read-write | mandatory |
| smNinePortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 9. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.7 | OCTET STRING | read-only | mandatory |
| smNinePortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 9. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.8 | OCTET STRING | read-only | mandatory |
| smNinePortCfgMedia OBJECT-TYPE Port media type of Switch Module 9. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smNinePortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 9. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smNinePortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.11 | INTEGER | read-only | mandatory |
| smNinePortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.12 | INTEGER | read-only | mandatory |
| smNinePortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.13 | OCTET STRING | read-only | mandatory |
| smNinePortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.14 | OCTET STRING | read-only | mandatory |
| smNinePortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smNinePortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| switchModTenPortCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10 | |||
| smTenPortCfgTable OBJECT-TYPE Switch Module 10 port configuration information. Note: This option is not supported on all I/O modules. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1 | not-accessible | mandatory | |
| smTenPortCfgEntry OBJECT-TYPE Switch Module 10 port configuration information table entry | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1 | not-accessible | mandatory | |
| smTenPortCfgIndex OBJECT-TYPE Switch Module 10 port sequence index. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.1 | INTEGER | read-only | mandatory |
| smTenPortCfgLabel OBJECT-TYPE Switch Module 10 port label | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.2 | OCTET STRING | read-only | mandatory |
| smTenPortCfgType OBJECT-TYPE Switch Module 10 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.3 | INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)} | read-only | mandatory |
| smTenPortCfgLinkSetting OBJECT-TYPE Current port link setting for Switch Module 10. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.4 | INTEGER {down(0), up(1)} | read-write | mandatory |
| smTenPortCfgLinkState OBJECT-TYPE Current port link state of Switch Module 10. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.5 | INTEGER {down(0), up(1), initialized(2)} | read-only | mandatory |
| smTenPortCfgSpeedSetting OBJECT-TYPE Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTenPortCfgAvailSpeeds are applicable to setting this mib object. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.6 | OCTET STRING | read-write | mandatory |
| smTenPortCfgSpeedStatus OBJECT-TYPE Current port speed of Switch Module 10. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.7 | OCTET STRING | read-only | mandatory |
| smTenPortCfgAvailSpeeds OBJECT-TYPE Available speed setting per port for Switch Module 10. If there is more than one setting, the speeds are separated by a comma and then a space. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.8 | OCTET STRING | read-only | mandatory |
| smTenPortCfgMedia OBJECT-TYPE Port media type of Switch Module 10. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.9 | INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)} | read-only | mandatory |
| smTenPortCfgProtocol OBJECT-TYPE Port protocol of Switch Module 10. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.10 | INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)} | read-only | mandatory |
| smTenPortCfgWidth OBJECT-TYPE The width of the port in terms of how many combined cables are present for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.11 | INTEGER | read-only | mandatory |
| smTenPortCfgCableLength OBJECT-TYPE The length (in meters) of the cable supported by this port for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.12 | INTEGER | read-only | mandatory |
| smTenPortCfgCableType OBJECT-TYPE External cable type for this port, for example, active copper or passive fiber. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.13 | OCTET STRING | read-only | mandatory |
| smTenPortCfgVendorName OBJECT-TYPE The cable manufacturer. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.14 | OCTET STRING | read-only | mandatory |
| smTenPortCfgCompatibility OBJECT-TYPE Compatibility of the external cable that is plugged into the port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.15 | INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)} | read-only | mandatory |
| smTenPortCfgDataRate OBJECT-TYPE Data rate supported for this port. | 1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.16 | INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)} | read-only | mandatory |
| raidControllerConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.3 | |||
| raidControllerTable OBJECT-TYPE RAID Controller control table. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1 | not-accessible | mandatory | |
| raidControllerEntry OBJECT-TYPE RAID Controller control table entry. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1 | not-accessible | mandatory | |
| raidControllerIndex OBJECT-TYPE RAID Controller control table index. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.1 | INTEGER | read-only | mandatory |
| raidControllerId OBJECT-TYPE The I/O Module numeric identifier for the SAS Controller Module. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.2 | INTEGER {module3(3), module4(4)} | read-only | mandatory |
| raidControllerExists OBJECT-TYPE Indicates whether the I/O Module specified for the RAID Controller exists or not. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| raidControllerPowerState OBJECT-TYPE Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.4 | INTEGER {off(0), on(1), shutdownInProgress(2)} | read-only | mandatory |
| raidControllerMACAddress OBJECT-TYPE The MAC address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.5 | OCTET STRING | read-only | mandatory |
| raidControllerSasID OBJECT-TYPE The hardware VPD SAS ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.6 | OCTET STRING | read-only | mandatory |
| raidControllerPingRequest OBJECT-TYPE Sends a ping to the current IP address of the RAID Controller network interface. This MIB object can not be set, if AMM grants I/O Module the Protected Mode permission and the module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.7 | INTEGER | read-write | mandatory |
| raidControllerNetworkCfg OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.3.3.2 | |||
| rcCurrentIPInfoTable OBJECT-TYPE RAID Controller current IP table. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1 | not-accessible | mandatory | |
| rcCurrentIPInfoEntry OBJECT-TYPE RAID Controller current IP table entry. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1 | not-accessible | mandatory | |
| rcCurrentIPInfoIndex OBJECT-TYPE RAID Controller current IP table index. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.1 | INTEGER | read-only | mandatory |
| rcCurrentIPInfoId OBJECT-TYPE The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.2 | INTEGER {module3(3), module4(4)} | read-only | mandatory |
| rcCurrentIPInfoExists OBJECT-TYPE Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| rcCurrentIPInfoPowerState OBJECT-TYPE Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.4 | INTEGER {off(0), on(1), shutdownInProgress(2)} | read-only | mandatory |
| rcCurrentIPAddr OBJECT-TYPE The current IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.5 | IpAddress | read-only | mandatory |
| rcCurrentSubnetMask OBJECT-TYPE The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.6 | IpAddress | read-only | mandatory |
| rcCurrentGateway OBJECT-TYPE The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.7 | IpAddress | read-only | mandatory |
| rcCurrentIPConfigMethod OBJECT-TYPE The current IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.8 | INTEGER {unknown(0), static(1), dhcp(2)} | read-only | mandatory |
| rcCurrentRaidedVlanId OBJECT-TYPE The current virtual LAN ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.9 | INTEGER | read-only | mandatory |
| rcNewIPInfoTable OBJECT-TYPE RAID Controller new IP configuration table. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2 | not-accessible | mandatory | |
| rcNewIPInfoEntry OBJECT-TYPE RAID Controller new IP configuration information table entry. This MIB object is for SAS Controller Modules only. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1 | not-accessible | mandatory | |
| rcNewIPInfoIndex OBJECT-TYPE RAID Controller new IP configuration information index. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.1 | INTEGER | read-only | mandatory |
| rcNewIPInfoId OBJECT-TYPE The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.2 | INTEGER {module3(3), module4(4)} | read-only | mandatory |
| rcNewIPInfoExists OBJECT-TYPE Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| rcNewIPInfoPowerState OBJECT-TYPE Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.4 | INTEGER {off(0), on(1), shutdownInProgress(2)} | read-only | mandatory |
| rcNewIPAddr OBJECT-TYPE The new IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.5 | IpAddress | read-write | mandatory |
| rcNewSubnetMask OBJECT-TYPE The new subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.6 | IpAddress | read-write | mandatory |
| rcNewGateway OBJECT-TYPE The new IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.7 | IpAddress | read-write | mandatory |
| rcNewIPConfigMethod OBJECT-TYPE The new IP configuration method for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: The value 'DHCP' can not be used to set. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.8 | INTEGER {unknown(0), static(1), dhcp(2)} | read-write | mandatory |
| rcNewIPConfigEnableDisable OBJECT-TYPE A set command enables new IP configurations that have been defined. A get command indicates whether new IP configurations that have been enabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. | 1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.11 | INTEGER {disable(0), enable(1)} | read-write | mandatory |
| chassisTopology OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.4 | |||
| chassisResponseVersion OBJECT-TYPE Chassis response version. | 1.3.6.1.4.1.2.3.51.2.22.4.1 | INTEGER | read-only | mandatory |
| chassisFlags OBJECT-TYPE Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.2 | INTEGER {rackOrStandAlone(0), serverBlade(1)} | read-only | mandatory |
| chassisName OBJECT-TYPE The name of the active MM as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.4.3 | OCTET STRING | read-only | mandatory |
| chassisNoOfFPsSupported OBJECT-TYPE Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.18 | INTEGER | read-only | mandatory |
| chassisNoOfPBsSupported OBJECT-TYPE Number of processor blades (PBs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.19 | INTEGER | read-only | mandatory |
| chassisNoOfSMsSupported OBJECT-TYPE Number of switch modules (SMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.20 | INTEGER | read-only | mandatory |
| chassisNoOfMMsSupported OBJECT-TYPE Number of management modules (MMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.21 | INTEGER | read-only | mandatory |
| chassisNoOfPMsSupported OBJECT-TYPE Number of power modules (PMs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.22 | INTEGER | read-only | mandatory |
| chassisNoOfMTsSupported OBJECT-TYPE Number of media trays (MTs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.23 | INTEGER | read-only | mandatory |
| chassisNoOfBlowersSupported OBJECT-TYPE Number of blowers supported. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.24 | INTEGER | read-only | mandatory |
| chassisPBsInstalled OBJECT-TYPE The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. | 1.3.6.1.4.1.2.3.51.2.22.4.25 | OCTET STRING | read-only | mandatory |
| chassisSMsInstalled OBJECT-TYPE The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT. | 1.3.6.1.4.1.2.3.51.2.22.4.29 | OCTET STRING | read-only | mandatory |
| chassisMMsInstalled OBJECT-TYPE The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.30 | OCTET STRING | read-only | mandatory |
| chassisPMsInstalled OBJECT-TYPE The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'. | 1.3.6.1.4.1.2.3.51.2.22.4.31 | OCTET STRING | read-only | mandatory |
| chassisMTInstalled OBJECT-TYPE Indicates whether at least one media tray (MT) is installed. | 1.3.6.1.4.1.2.3.51.2.22.4.32 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| chassisBlowersInstalled OBJECT-TYPE The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.33 | OCTET STRING | read-only | mandatory |
| chassisActiveMM OBJECT-TYPE The active management module (MM). | 1.3.6.1.4.1.2.3.51.2.22.4.34 | INTEGER | read-only | mandatory |
| chassisKVMOwner OBJECT-TYPE The blade that currently owns the keyboard/video/monitor (KVM). 0 = the KVM devices are owned by the management module. | 1.3.6.1.4.1.2.3.51.2.22.4.35 | INTEGER | read-only | mandatory |
| chassisMediaTrayOwner OBJECT-TYPE The blade that currently owns the media tray. 0 = the media tray is owned by the management module. | 1.3.6.1.4.1.2.3.51.2.22.4.36 | INTEGER | read-only | mandatory |
| chassisFPsInstalled OBJECT-TYPE The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices. | 1.3.6.1.4.1.2.3.51.2.22.4.37 | OCTET STRING | read-only | mandatory |
| chassisType OBJECT-TYPE The type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the bladeCenterOrBladeCenterH type. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.38 | INTEGER {bladeCenterOrBladeCenterH(97), bladeCenterTOrBladeCenterHT(98)} | read-only | mandatory |
| chassisSubtype OBJECT-TYPE The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis. | 1.3.6.1.4.1.2.3.51.2.22.4.39 | INTEGER {bladeCenterOrBladeCenterT(0), bladeCenterHOrBladeCenterHT(2), bladeCenterS(3), bladeCenterE(4), bladeCenterH(5), bladeCenterT(32), unknown(255)} | read-only | mandatory |
| chassisNoOfFBsSupported OBJECT-TYPE Number of Front Bezel (FBs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.40 | INTEGER | read-only | mandatory |
| chassisNoOfAPsSupported OBJECT-TYPE Number of Alarm Panel (APs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.41 | INTEGER | read-only | mandatory |
| chassisNoOfNCsSupported OBJECT-TYPE Number of Network Clocks (NCs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.42 | INTEGER | read-only | deprecated |
| chassisNoOfMXsSupported OBJECT-TYPE Number of Multiplexer Expansion modules (MXs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.43 | INTEGER | read-only | mandatory |
| chassisNoOfMMIsSupported OBJECT-TYPE Number of management module interposers (MMIs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.44 | INTEGER | read-only | mandatory |
| chassisNoOfSMIsSupported OBJECT-TYPE Number of switch module interposers (SMIs) supported. | 1.3.6.1.4.1.2.3.51.2.22.4.45 | INTEGER | read-only | mandatory |
| chassisNoOfFBsInstalled OBJECT-TYPE The return value of '1'indicates the front bezel is installed on the chassis. The value of '0' indicates the front bezel is not installed. | 1.3.6.1.4.1.2.3.51.2.22.4.46 | OCTET STRING | read-only | mandatory |
| chassisNoOfAPsInstalled OBJECT-TYPE The return value of '1'indicates the alarm panel is installed on the chassis. The value of '0' indicates the alarm panel is not installed. | 1.3.6.1.4.1.2.3.51.2.22.4.47 | OCTET STRING | read-only | mandatory |
| chassisNoOfNCsInstalled OBJECT-TYPE The network clock cards that are installed on the chassis. The network clock cards are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of network clock cards supported. If a network clock card is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a network clock card is installed in bays 1, and 2 network clock cards are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.48 | OCTET STRING | read-only | deprecated |
| chassisNoOfMXsInstalled OBJECT-TYPE The Multiplexer Expansion Modules that are installed on the chassis. The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of Multiplexer Expansion Modules supported. If a Multiplexer Expansion Module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if Multiplexer Expansion Module is installed in bays 1, and 2 Multiplexer Expansion Modules are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.49 | OCTET STRING | read-only | mandatory |
| chassisNoOfMMIsInstalled OBJECT-TYPE The flex cables that are installed on the chassis. The flex cables are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of flex cables supported. If a flex cable is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if flex cable is installed in bays 1, and 2 flex cables are supported, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.50 | OCTET STRING | read-only | mandatory |
| chassisNoOfSMIsInstalled OBJECT-TYPE The interposers that are installed on the chassis. The interposers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of interposers supported. If an interposer is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if interposer is installed in bays 1, and 10 interposers are supported, the string would look like '1000000000'. | 1.3.6.1.4.1.2.3.51.2.22.4.51 | OCTET STRING | read-only | mandatory |
| chassisNoOfMTsInstalled OBJECT-TYPE The media trays that are installed on the chassis. The media trays are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of media trays supported. If a media tray is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if media trays are installed in bays 1, and 2 media trays are, the string would look like '10'. | 1.3.6.1.4.1.2.3.51.2.22.4.52 | OCTET STRING | read-only | mandatory |
| managementModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.5 | |||
| mmStatusTable OBJECT-TYPE Table of the management module status. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.22.5.1 | not-accessible | mandatory | |
| mmStatusEntry OBJECT-TYPE Management module status entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1 | not-accessible | mandatory | |
| mmStatusIndex OBJECT-TYPE Management module status index. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.1 | INTEGER | read-only | mandatory |
| mmPresent OBJECT-TYPE Management module current status. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.2 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mmExtIpAddress OBJECT-TYPE Management module external IP address. NOTE: The IPv6 addresses assigned to the AMM may be viewed with the extEthernetInterfaceIPv6 objects | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.3 | IpAddress | read-only | mandatory |
| mmPrimary OBJECT-TYPE Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.4 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| mmHealthState OBJECT-TYPE The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad. | 1.3.6.1.4.1.2.3.51.2.22.5.1.1.5 | INTEGER {unknown(0), good(1), warning(2), bad(3)} | read-only | mandatory |
| storage OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.6 | |||
| storageStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.6.1 | |||
| storageStatusTable OBJECT-TYPE Table of the storage module status. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1 | not-accessible | mandatory | |
| storageStatusEntry OBJECT-TYPE Storage Module Status Table Entry. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1 | not-accessible | mandatory | |
| storageStatusIndex OBJECT-TYPE Storage device status table index. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.1 | INTEGER | read-only | mandatory |
| storageBayNumber OBJECT-TYPE Bay number of the Storage device. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.2 | OCTET STRING | read-only | mandatory |
| storageState OBJECT-TYPE Storage device state. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.3 | INTEGER {unknown(0), good(1), warning(2), critical(3), notAvailable(255)} | read-only | mandatory |
| storageName OBJECT-TYPE The name of the storage device. | 1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.4 | OCTET STRING | read-only | mandatory |
| storageConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.6.2 | |||
| storageSwitchConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.6.2.1 | |||
| storageSwitchZoneCfgTable OBJECT-TYPE Table of all the zone configurations stored on switch modules. For consistent results, view as a table and not as individual entries. Before activating a new zone configuration via the switchActiveZoneCfg object, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1 | not-accessible | mandatory | |
| storageSwitchZoneCfgEntry OBJECT-TYPE Switch Module Zone Configuration Management Entry. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1 | not-accessible | mandatory | |
| switchZoneCfgIndex OBJECT-TYPE Switch module zone configuration table index. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.1 | INTEGER | read-only | mandatory |
| switchZoneCfgBayNumber OBJECT-TYPE The numeric switch bay number. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.2 | INTEGER | read-only | mandatory |
| switchZoneCfgNumber OBJECT-TYPE The zone configuration number, also referred to as the configuration store number. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.3 | INTEGER | read-only | mandatory |
| switchZoneCfgStatus OBJECT-TYPE The status of the zone configuration. Only one configuration is 'Active', others are in 'nonActive' status. When a zone configuration is active on a switch, the status may temporarily indicate pending(2) as it transitions from nonActive(0) to active (1). | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.4 | INTEGER {nonActive(0), active(1), pending(2)} | read-only | mandatory |
| switchZoneCfgType OBJECT-TYPE The type of the zone configuration. Predefined are read-only static configurations, and userdefined are read-write configurations that can be created and modified using the Switch Configuration Manager application. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.5 | INTEGER {userdefined(1), predefined(2)} | read-only | mandatory |
| switchZoneCfgName OBJECT-TYPE A short descriptive name for the zone configuration. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.6 | OCTET STRING | read-only | mandatory |
| switchZoneCfgDescription OBJECT-TYPE A detailed description for the zone configuration. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.7 | OCTET STRING | read-only | mandatory |
| switchZoneCfgDate OBJECT-TYPE The date the zone configuration was created. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.8 | OCTET STRING | read-only | mandatory |
| switchActiveZoneCfg OBJECT-TYPE An object used to activate a particular zone configuration. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.9 | INTEGER {execute(1)} | read-write | mandatory |
| storageSwitchActiveZoneCfgTable OBJECT-TYPE Table showing the zone configuration that is currently active on a given switch module. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2 | not-accessible | mandatory | |
| storageSwitchActiveZoneCfgEntry OBJECT-TYPE Active zone configurations Entry. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1 | not-accessible | mandatory | |
| activeZoneCfgIndex OBJECT-TYPE Active zone configurations table index. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.1 | INTEGER | read-only | mandatory |
| activeZoneCfgBayNumber OBJECT-TYPE Bay number of the switch module where active zone configurations exist. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.2 | OCTET STRING | read-only | mandatory |
| activeZoneCfgNumberBySwitch OBJECT-TYPE The zone configuration number active on this SAS switch module as reported by the switch module. If this number differs from the value of the activeZoneCfgNumberByMM object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 253 = I/O module is discovering zone information. 254 = I/O Module is not powered on or in a fault state. 255 = notApplicable. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.3 | INTEGER | read-only | mandatory |
| activeZoneCfgNumberByMM OBJECT-TYPE The zone configuration number active on this SAS switch module as known by the management module. If this number differs from the value of the activeZoneCfgNumberBySwitch object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 255 = notApplicable. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.4 | INTEGER | read-only | mandatory |
| switchZoneCfgActivation OBJECT-TYPE This object provides a quick means of activating a valid zone configuration on all active SAS switches. The zone configuration to be activated is specified as the value of the SET and can be obtained from the switchZoneCfgNumber object. The zone configuration number is also referred to as the zone configuration store. Before activating a new zone configuration, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned. NOTE: Value returned for the GET command is meaningless for this MIB object. If any of the switches are not activated, an error response will be returned. | 1.3.6.1.4.1.2.3.51.2.22.6.2.1.3 | INTEGER | read-write | mandatory |
| firmwareInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.8 | |||
| smFirmwareInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.8.1 | |||
| smFirmwareInfoTable OBJECT-TYPE Switch Module firmware image information. This table is only applicable to modules that support multiple images | 1.3.6.1.4.1.2.3.51.2.22.8.1.1 | not-accessible | mandatory | |
| smFirmwareInfoEntry OBJECT-TYPE Switch Module firmware image information table entry | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1 | not-accessible | mandatory | |
| smFirmwareInfoIndex OBJECT-TYPE Sequence index in the firmware table. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1 | INTEGER | read-only | mandatory |
| smFirmwareInfoModIndex OBJECT-TYPE Switch Module number. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2 | INTEGER | read-only | mandatory |
| smFirmwareInfoImageIndex OBJECT-TYPE Switch Module firmware image index. | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3 | INTEGER | read-only | mandatory |
| smFirmwareInfoImageName OBJECT-TYPE Switch Module firmware image name | 1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4 | OCTET STRING | read-write | mandatory |
| firmwareUpdate OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.9 | |||
| firmwareUpdateTarget OBJECT-TYPE Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error. | 1.3.6.1.4.1.2.3.51.2.22.9.1 | INTEGER {managementModule(0), switchModule1(11), switchModule2(12), switchModule3(13), switchModule4(14), switchModule5(15), switchModule6(16), switchModule7(17), switchModule8(18), switchModule9(19), switchModule10(20), blade1(31), blade2(32), blade3(33), blade4(34), blade5(35), blade6(36), blade7(37), blade8(38), blade9(39), blade10(40), blade11(41), blade12(42), blade13(43), blade14(44), unknown(255)} | read-write | mandatory |
| firmwareUpdateTftpServer OBJECT-TYPE If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]). | 1.3.6.1.4.1.2.3.51.2.22.9.2 | OCTET STRING (SIZE(0..63)) | read-write | mandatory |
| firmwareUpdateFileName OBJECT-TYPE File name of the firmware file. | 1.3.6.1.4.1.2.3.51.2.22.9.3 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| firmwareUpdateStart OBJECT-TYPE Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the AMM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.9.4 | INTEGER {execute(1), execute-with-reboot(2), execute-nowait(3), execute-with-reboot-nowait(4)} | read-write | mandatory |
| firmwareUpdateStatus OBJECT-TYPE Get the status of the last firmware update which was initiated through SNMP method. | 1.3.6.1.4.1.2.3.51.2.22.9.5 | OCTET STRING | read-only | mandatory |
| standbyFirmwareUpdateStatus OBJECT-TYPE Get the current status of the firmware update for the standby AMM. NOTE: This only applies to systems with a standby AMM. | 1.3.6.1.4.1.2.3.51.2.22.9.6 | OCTET STRING | read-only | mandatory |
| firmwareImageNumber OBJECT-TYPE If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section. | 1.3.6.1.4.1.2.3.51.2.22.9.7 | INTEGER | read-write | mandatory |
| firmwareActiveImage OBJECT-TYPE If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.9.8 | INTEGER | read-write | mandatory |
| firmwareUpdateServer OBJECT-TYPE Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: CNETCMUS.pkt Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>. | 1.3.6.1.4.1.2.3.51.2.22.9.9 | OCTET STRING (SIZE(0..254)) | read-write | mandatory |
| remoteChassis OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.10 | |||
| remoteChassisTable OBJECT-TYPE Table of remote chassis information. | 1.3.6.1.4.1.2.3.51.2.22.10.1 | not-accessible | mandatory | |
| remoteChassisEntry OBJECT-TYPE Remote chassis entry | 1.3.6.1.4.1.2.3.51.2.22.10.1.1 | not-accessible | mandatory | |
| remoteChassisIndex OBJECT-TYPE Remote chassis discovery sequence index. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.1 | INTEGER | read-only | mandatory |
| systemName OBJECT-TYPE System name for this discovery management module. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.2 | OCTET STRING | read-only | mandatory |
| systemStatus OBJECT-TYPE System status summary (chassis). | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.3 | INTEGER {critical(0), non-Critical(2), system-Level(4), unknown(9), noResponse(170), normal(255)} | read-only | mandatory |
| mmType OBJECT-TYPE Service processor type. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.4 | OCTET STRING | read-only | mandatory |
| mmSerial OBJECT-TYPE Management module serial number. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.5 | OCTET STRING | read-only | mandatory |
| mmFru OBJECT-TYPE Management module Field-Replaceable number. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.6 | OCTET STRING | read-only | mandatory |
| mmIp OBJECT-TYPE The IPv4 compliant address of the management module. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.7 | OCTET STRING | read-write | mandatory |
| chassisSerial OBJECT-TYPE Chassis serial number. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.8 | OCTET STRING | read-only | mandatory |
| chassisFru OBJECT-TYPE Chassis Field-Replaceable number. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.9 | OCTET STRING | read-only | mandatory |
| chassisMachineTypeMode OBJECT-TYPE Chassis machine type and model number. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.10 | OCTET STRING | read-only | mandatory |
| chassisUuid OBJECT-TYPE Chassis unique identifier. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.11 | OCTET STRING | read-only | mandatory |
| firmwareVersion OBJECT-TYPE Firmware version of the discovery management module. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.12 | OCTET STRING | read-only | mandatory |
| ipStatus OBJECT-TYPE A flag to state if IPv4 and IPv6 are enabled | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.13 | INTEGER {ipv4(1), ipv6(2), both(3)} | read-only | mandatory |
| ipv6Addresses OBJECT-TYPE The IPv6 addresses configured for the chassis. | 1.3.6.1.4.1.2.3.51.2.22.10.1.1.14 | OCTET STRING | read-only | mandatory |
| chassisDiscovery OBJECT-TYPE Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.10.2 | INTEGER {execute(1)} | read-write | mandatory |
| fileManagement OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.11 | |||
| fileTopology OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.11.1 | |||
| currentDirectory OBJECT-TYPE Specifies the directory name for listing the requested files. | 1.3.6.1.4.1.2.3.51.2.22.11.1.1 | OCTET STRING | read-write | mandatory |
| fileDetailsTable OBJECT-TYPE A table of all the files in the specified directory. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2 | not-accessible | mandatory | |
| fileDetailsEntry OBJECT-TYPE File details entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1 | not-accessible | mandatory | |
| fileIndex OBJECT-TYPE File sequence index. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1 | INTEGER | read-only | mandatory |
| fileName OBJECT-TYPE File name. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2 | OCTET STRING | read-only | mandatory |
| fileLastUpdate OBJECT-TYPE Date of the latest file update. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3 | OCTET STRING | read-only | mandatory |
| fileSize OBJECT-TYPE File size in bytes. | 1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4 | OCTET STRING | read-only | mandatory |
| fileManagementCmd OBJECT-TYPE This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.22.11.3 | OCTET STRING | read-write | mandatory |
| fileSystemSpaceAvailable OBJECT-TYPE This field displays the available space of the AMM file system. | 1.3.6.1.4.1.2.3.51.2.22.11.6 | OCTET STRING | read-only | mandatory |
| componentMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.22.37 | |||
| componentMACAddressTable OBJECT-TYPE Table of MAC address VPD information for each component. | 1.3.6.1.4.1.2.3.51.2.22.37.11 | not-accessible | mandatory | |
| componentMACAddressEntry OBJECT-TYPE Component MAC address table entry | 1.3.6.1.4.1.2.3.51.2.22.37.11.1 | not-accessible | mandatory | |
| componentMACAddressTopologyPath OBJECT-TYPE The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.1 | OCTET STRING (SIZE(0..100)) | read-only | mandatory |
| componentMACAddressIndex OBJECT-TYPE Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.2 | INTEGER | read-only | mandatory |
| componentMACAddressName OBJECT-TYPE The name of the component as a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.3 | OCTET STRING | read-only | mandatory |
| componentMACAddress OBJECT-TYPE The MAC address VPD value for this component and index. The value is a null terminated string. | 1.3.6.1.4.1.2.3.51.2.22.37.11.1.4 | OCTET STRING | read-only | mandatory |
| service OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23 | |||
| serviceConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.1 | |||
| debugEnable OBJECT-TYPE Disable/Enable AMM debugging with USB key by service personnel. | 1.3.6.1.4.1.2.3.51.2.23.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | deprecated |
| bladeServiceData OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.3 | |||
| bladeServiceDataTable OBJECT-TYPE Table of blade service data information. | 1.3.6.1.4.1.2.3.51.2.23.3.1 | not-accessible | mandatory | |
| bladeServiceDataEntry OBJECT-TYPE Blade service data entry | 1.3.6.1.4.1.2.3.51.2.23.3.1.1 | not-accessible | mandatory | |
| serviceDataIndex OBJECT-TYPE Blade service date index. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.1 | INTEGER | read-only | mandatory |
| serviceDataBladeId OBJECT-TYPE The numeric blade ID. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.2 | INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)} | read-only | mandatory |
| serviceDataBladeExists OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.3 | INTEGER {false(0), true(1)} | read-only | mandatory |
| serviceDataBladePowerState OBJECT-TYPE Indicates whether the blade specified is powered on or not. If the AMM is experiencing a communication problem with the blade, the state may be returned as unknown(255) | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.4 | INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)} | read-only | mandatory |
| serviceDataBladeName OBJECT-TYPE The name of the blade as a string. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.5 | OCTET STRING | read-only | mandatory |
| serviceDataBladeCapability OBJECT-TYPE Indicates whether the blade has the capability to trigger service data. NOTE: This Mib object is deprecated and no longer supported. Please see serviceDataBladeCapabilityMask OID | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.6 | INTEGER | read-only | deprecated |
| serviceDataDumpInitiate OBJECT-TYPE Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. Only one file can be moved to the'/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.7 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| serviceDataDumpRetrieve OBJECT-TYPE Retrieve a type of service data file from blade to AMM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. Only one file can be moved to the '/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.8 | INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)} | read-write | mandatory |
| serviceDataDumpCapabilityMask OBJECT-TYPE Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the AMM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the AMM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the AMM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the AMM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the AMM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the AMM | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.9 | OCTET STRING | read-only | mandatory |
| serviceDataDumpInProgress OBJECT-TYPE An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the AMM and where the dump file is transferred to the AMM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned. | 1.3.6.1.4.1.2.3.51.2.23.3.1.1.10 | INTEGER {inProgress(1), notInProgress(2), unknown(255)} | read-only | mandatory |
| bladeSystemReferenceCodes OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.3.3 | |||
| bladeSysRefCodesTable OBJECT-TYPE Table of blade system reference codes. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1 | not-accessible | mandatory | |
| bladeSysRefCodesEntry OBJECT-TYPE Boot sequence entry | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1 | not-accessible | mandatory | |
| sysRefCodeIndex OBJECT-TYPE System reference codes index. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.1 | INTEGER | read-only | mandatory |
| sysRefCodeBayNumber OBJECT-TYPE The bay number of the blade which has the system reference code. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.2 | OCTET STRING | read-only | mandatory |
| sysRefCodeSequence OBJECT-TYPE Indicates whether the blade specified exists or not. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.3 | INTEGER | read-only | mandatory |
| sysRefCode OBJECT-TYPE Unique ID and system reference code for the blade. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.4 | OCTET STRING | read-write | mandatory |
| sysRefCodeTimestamp OBJECT-TYPE Timestamp of system reference code for the blade. | 1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.5 | OCTET STRING | read-write | mandatory |
| bladeSysRefCodesDetailsTable OBJECT-TYPE Table of details of blade system reference codes. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2 | not-accessible | mandatory | |
| bladeSysRefCodesDetailsEntry OBJECT-TYPE Boot sequence entry | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1 | not-accessible | mandatory | |
| sysRefCodeDetailIndex OBJECT-TYPE System reference codes index. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.1 | INTEGER | read-only | mandatory |
| sysRefCodeDetailBayNumber OBJECT-TYPE The bay number of the blade which has the details of system reference code. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.2 | OCTET STRING | read-only | mandatory |
| sysRefCodeDetailSRCSequence OBJECT-TYPE A sequence of the system reference codes for the blade. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.3 | INTEGER | read-only | mandatory |
| sysRefCodeDetailSequence OBJECT-TYPE A sequence of the detailed information of the system reference codes for the blade. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.4 | OCTET STRING | read-write | mandatory |
| sysRefCodeDetailDataString OBJECT-TYPE Detailed information of the system reference codes for the blade. | 1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.5 | OCTET STRING | read-write | mandatory |
| serviceAdvisor OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4 | |||
| autoCallHomeSetup OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.1 | |||
| acceptLicenseAgreement OBJECT-TYPE Accept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If AMM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the IBM BladeCenter User's Guide. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed. | 1.3.6.1.4.1.2.3.51.2.23.4.1.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| serviceAdvisorEnable OBJECT-TYPE Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled. | 1.3.6.1.4.1.2.3.51.2.23.4.1.2 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| serviceSupportCenter OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.2 | |||
| ibmSupportCenter OBJECT-TYPE The country code for the IBM Support Center. 2 character ISO country code. | 1.3.6.1.4.1.2.3.51.2.23.4.2.1 | OCTET STRING | read-write | mandatory |
| contactInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.3 | |||
| companyName OBJECT-TYPE The organization/company name of the contact person. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.1 | OCTET STRING | read-write | mandatory |
| contactName OBJECT-TYPE The name of the contact person.1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.2 | OCTET STRING | read-write | mandatory |
| phoneNumber OBJECT-TYPE The phone of the contact person. 5-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.3 | OCTET STRING | read-write | mandatory |
| emailAddress OBJECT-TYPE The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.4 | OCTET STRING | read-write | mandatory |
| address OBJECT-TYPE The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.5 | OCTET STRING | read-write | mandatory |
| city OBJECT-TYPE The city of the machine location. 1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.6 | OCTET STRING | read-write | mandatory |
| state OBJECT-TYPE The state of the machine location. 2-3 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.7 | OCTET STRING | read-write | mandatory |
| postalCode OBJECT-TYPE The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid. | 1.3.6.1.4.1.2.3.51.2.23.4.3.8 | OCTET STRING | read-write | mandatory |
| phoneNumberExt OBJECT-TYPE The extension of the phone. 30 characters maximum. | 1.3.6.1.4.1.2.3.51.2.23.4.3.10 | OCTET STRING | read-write | mandatory |
| altContactName OBJECT-TYPE (Optional) The name of the alternate contact person.1-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.11 | OCTET STRING | read-write | mandatory |
| altPhoneNumber OBJECT-TYPE (Optional) The phone of the alternate contact person. 5-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.12 | OCTET STRING | read-write | mandatory |
| altPhoneNumberExt OBJECT-TYPE (Optional) The extension of the alternate phone. 30 characters maximum. | 1.3.6.1.4.1.2.3.51.2.23.4.3.13 | OCTET STRING | read-write | mandatory |
| altEmailAddress OBJECT-TYPE (Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.14 | OCTET STRING | read-write | mandatory |
| machineLocPhone OBJECT-TYPE (Optional) The contact phone number of the machine location. 5-30 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.3.15 | OCTET STRING | read-write | mandatory |
| httpProxyConfig OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.4 | |||
| httpProxyEnable OBJECT-TYPE Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not connected to the internet directly. | 1.3.6.1.4.1.2.3.51.2.23.4.4.1 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| httpProxyLocation OBJECT-TYPE Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters. | 1.3.6.1.4.1.2.3.51.2.23.4.4.2 | OCTET STRING | read-write | mandatory |
| httpProxyPort OBJECT-TYPE The port number of the HTTP Proxy. An integer value from 1 to 65535. | 1.3.6.1.4.1.2.3.51.2.23.4.4.3 | INTEGER | read-write | mandatory |
| httpProxyUserName OBJECT-TYPE User Name of the HTTP Proxy. A maximum of 30 characters string without spaces. | 1.3.6.1.4.1.2.3.51.2.23.4.4.4 | OCTET STRING | read-write | mandatory |
| httpProxyPassword OBJECT-TYPE Password of the HTTP Proxy. A maximum of 15 characters string without spaces. | 1.3.6.1.4.1.2.3.51.2.23.4.4.5 | OCTET STRING | read-write | mandatory |
| activityLogs OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.4.5 | |||
| activityLogTable OBJECT-TYPE Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1 | not-accessible | mandatory | |
| activityLogEntry OBJECT-TYPE Activity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by IBM support, the event ID, event source, date and time that event occured, and a text message. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1 | not-accessible | mandatory | |
| activityLogIndex OBJECT-TYPE The Activity Log index number. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1 | INTEGER | read-only | mandatory |
| activityLogString OBJECT-TYPE A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2 | OCTET STRING | read-only | mandatory |
| activityLogAcknowledge OBJECT-TYPE The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at IBM support. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via IBM Support or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3 | INTEGER {no(0), yes(1)} | read-write | mandatory |
| activityLogAttribute OBJECT-TYPE A string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to IBM support or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling IBM Support or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting IBM support. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4 | OCTET STRING | read-only | mandatory |
| autoFTPSetup OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.5 | |||
| autoFTPCallMode OBJECT-TYPE This field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component. | 1.3.6.1.4.1.2.3.51.2.23.5.1 | INTEGER {disabled(0), ftp(1), tftp(2)} | read-write | mandatory |
| autoFTPCallAddr OBJECT-TYPE This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address. | 1.3.6.1.4.1.2.3.51.2.23.5.2 | OCTET STRING | read-write | mandatory |
| autoFTPCallPort OBJECT-TYPE This field specifies the port on remote FTP/TFTP server for data transmission. | 1.3.6.1.4.1.2.3.51.2.23.5.3 | INTEGER | read-write | mandatory |
| autoFTPCallUserID OBJECT-TYPE This field specifies the user account to login remote FTP server. | 1.3.6.1.4.1.2.3.51.2.23.5.4 | OCTET STRING | read-write | mandatory |
| autoFTPCallPassword OBJECT-TYPE This field specifies the password to login remote FTP server. | 1.3.6.1.4.1.2.3.51.2.23.5.5 | OCTET STRING | read-write | mandatory |
| callHomeExclusionEvents OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.23.6 | |||
| readCallHomeExclusionEventTable OBJECT-TYPE Table of Call Home Exclusion Event entries information. | 1.3.6.1.4.1.2.3.51.2.23.6.1 | not-accessible | mandatory | |
| readCallHomeExclusionEventEntry OBJECT-TYPE Call Home Exclusion Event table entry | 1.3.6.1.4.1.2.3.51.2.23.6.1.1 | not-accessible | mandatory | |
| readCallHomeExclusionEventIndex OBJECT-TYPE The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.1 | INTEGER | read-only | mandatory |
| readCallHomeExclusionEventID OBJECT-TYPE The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries. | 1.3.6.1.4.1.2.3.51.2.23.6.1.1.2 | OCTET STRING | read-only | mandatory |
| addCallHomeExclusionEvent OBJECT-TYPE Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.2 | OCTET STRING | read-write | mandatory |
| rmCallHomeExclusionEvent OBJECT-TYPE Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.3 | OCTET STRING | read-write | mandatory |
| rmAllCallHomeExclusionEvent OBJECT-TYPE Remove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object. | 1.3.6.1.4.1.2.3.51.2.23.6.4 | INTEGER {execute(1)} | read-write | mandatory |
| scaling OBJECT-IDENTITY | 1.3.6.1.4.1.2.3.51.2.24 | |||
| scalableComplexTable OBJECT-TYPE Table of scalable complex information. This table provides information and control actions related to the scalable complexes installed in the chassis. Partition, node and port information and control are defined in their own tables. | 1.3.6.1.4.1.2.3.51.2.24.1 | not-accessible | mandatory | |
| scalableComplexEntry OBJECT-TYPE Scalable complex information. | 1.3.6.1.4.1.2.3.51.2.24.1.1 | not-accessible | mandatory | |
| scalableComplexIdentifier OBJECT-TYPE The unique numeric identifier for a complex installed in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.1.1.1 | INTEGER | read-only | mandatory |
| scalableComplexNumPartitions OBJECT-TYPE The number of partitions currently defined for this complex. | 1.3.6.1.4.1.2.3.51.2.24.1.1.2 | INTEGER | read-only | mandatory |
| scalableComplexNumNodes OBJECT-TYPE The number of nodes existing in this complex, regardless of their assignment to any given partition. The physical slot location of the nodes can be determined from the scalableComplexNodeTable. | 1.3.6.1.4.1.2.3.51.2.24.1.1.3 | INTEGER | read-only | mandatory |
| scalableComplexPartStartSlot OBJECT-TYPE The lowest slot number occupied by the nodes in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation. | 1.3.6.1.4.1.2.3.51.2.24.1.1.4 | INTEGER | read-write | mandatory |
| scalableComplexPartNumNodes OBJECT-TYPE The number of nodes to be included in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation. | 1.3.6.1.4.1.2.3.51.2.24.1.1.5 | INTEGER | read-write | mandatory |
| scalableComplexAction OBJECT-TYPE This object allows various actions to be taken in relation to a particular complex. clear(1) - This clears all partition information related to the complex. Any nodes associated with the complex are no longer assigned to any partitions. All nodes in the complex must be powered off prior to attempting this operation, otherwise, the action will fail. autocreate(2) - This creates a single partition which includes all nodes associated with the complex. Any other prior partition definitions must be deleted prior to issuing this action, otherwise, the action will fail. create(3) - This allows the creation of a partition within the complex. Prior to triggering this action, the scalableComplexPartStartSlot and scalableComplexPartNumNodes objects must be set first to identify the starting slot number and number of nodes to be included in this new partition. The nodes chosen for inclusion in this new partition must not be part of another existing partition, otherwise, the action will fail. | 1.3.6.1.4.1.2.3.51.2.24.1.1.6 | INTEGER {clear(1), autocreate(2), create(3)} | write-only | mandatory |
| scalableComplexPartitionTable OBJECT-TYPE Table of scalable complex partition information. This table provides information and control actions related to the partitions defined across all of the complexes installed in the chassis. Complex, node and port information and control are defined in their own tables. | 1.3.6.1.4.1.2.3.51.2.24.2 | not-accessible | mandatory | |
| scalableComplexPartitionEntry OBJECT-TYPE Scalable complex partition information. | 1.3.6.1.4.1.2.3.51.2.24.2.1 | not-accessible | mandatory | |
| scalableComplexId OBJECT-TYPE The unique numeric identifier for a complex installed in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.2.1.1 | INTEGER | read-only | mandatory |
| scalableComplexPartitionIdentifier OBJECT-TYPE The unique numeric identifier for a partition defined within a complex installed in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.2.1.2 | INTEGER | read-only | mandatory |
| scalableComplexPartitionMode OBJECT-TYPE The currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a partition mode to stand-alone will cause subsequent partition actions to be ignored until the partition mode is restored. | 1.3.6.1.4.1.2.3.51.2.24.2.1.3 | INTEGER {partition(1), standalone(2)} | read-write | mandatory |
| scalableComplexPartitionNumNodes OBJECT-TYPE The number of nodes currently defined for this partition. | 1.3.6.1.4.1.2.3.51.2.24.2.1.4 | INTEGER | read-only | mandatory |
| scalableComplexPartitionStatus OBJECT-TYPE The current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition consitency check problem, the invalid state is provided. | 1.3.6.1.4.1.2.3.51.2.24.2.1.5 | INTEGER {poweredoff(1), poweredon(2), resetting(3), invalid(4)} | read-only | mandatory |
| scalableComplexPartitionAction OBJECT-TYPE This object allows various actions to be taken in relation to a particular partition in a given complex. delete(1) - Deletes the partition from the complex. All nodes in the partition must be powered off prior to attempting this operation, otherwise, the action will fail. poweron(2) - Powers up a powered off partition poweroff(3) - Powers off an already powered on partition powercycle(4) - Power cycles a partition | 1.3.6.1.4.1.2.3.51.2.24.2.1.6 | INTEGER {delete(1), poweron(2), poweroff(3), powercycle(4)} | write-only | mandatory |
| scalableComplexNodeTable OBJECT-TYPE Table of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partition and port information and control are defined in their own tables. | 1.3.6.1.4.1.2.3.51.2.24.3 | not-accessible | mandatory | |
| scalableComplexNodeEntry OBJECT-TYPE Scalable complex node information. | 1.3.6.1.4.1.2.3.51.2.24.3.1 | not-accessible | mandatory | |
| scalableComplexNodeSlot OBJECT-TYPE The base slot number where the node exists in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.3.1.1 | INTEGER | read-only | mandatory |
| scalableComplexNodeName OBJECT-TYPE The description string which uniquely identifies the blade. | 1.3.6.1.4.1.2.3.51.2.24.3.1.2 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| scalableComplexNodeType OBJECT-TYPE The general categorization of the node. | 1.3.6.1.4.1.2.3.51.2.24.3.1.3 | INTEGER {processor(1), memory(2), io(3)} | read-only | mandatory |
| scalableComplexNodeResources OBJECT-TYPE A string providing a summary overview of the resources provided by this node. | 1.3.6.1.4.1.2.3.51.2.24.3.1.4 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| scalableComplexNodeRole OBJECT-TYPE Indicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not. | 1.3.6.1.4.1.2.3.51.2.24.3.1.5 | INTEGER {primary(1), secondary(2), unassigned(255)} | read-only | mandatory |
| scalableComplexNodeState OBJECT-TYPE The physical power state of this node. | 1.3.6.1.4.1.2.3.51.2.24.3.1.6 | INTEGER {poweredoff(1), poweredon(2), resetting(3)} | read-only | mandatory |
| scalableComplexNodeUUID OBJECT-TYPE The Universally Unique IDentifier (UUID) of this node, represented as a 16 byte hex number. | 1.3.6.1.4.1.2.3.51.2.24.3.1.7 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| scalableComplexNodeSerialNum OBJECT-TYPE The serial number of this node. | 1.3.6.1.4.1.2.3.51.2.24.3.1.8 | OCTET STRING (SIZE(256)) | read-only | mandatory |
| scalableComplexNodeNumPorts OBJECT-TYPE The number of remote nodes that this node has links to. | 1.3.6.1.4.1.2.3.51.2.24.3.1.9 | INTEGER | read-only | mandatory |
| scalableComplexNodeComplexID OBJECT-TYPE For an assigned node, the identifier of the complex this node is related to. For an unassigned node, this object has no meaning. | 1.3.6.1.4.1.2.3.51.2.24.3.1.10 | INTEGER | read-only | mandatory |
| scalableComplexNodePartitionID OBJECT-TYPE For an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning. | 1.3.6.1.4.1.2.3.51.2.24.3.1.11 | INTEGER | read-only | mandatory |
| scalableComplexNodeLogicalID OBJECT-TYPE The unique numeric identifier for this node, unique within the partition. | 1.3.6.1.4.1.2.3.51.2.24.3.1.12 | INTEGER | read-only | mandatory |
| scalableComplexNodeAction OBJECT-TYPE The actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object. | 1.3.6.1.4.1.2.3.51.2.24.3.1.14 | INTEGER {poweroff(1), poweron(2)} | write-only | mandatory |
| scalableComplexNodePortTable OBJECT-TYPE Table of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control are defined in their own tables. | 1.3.6.1.4.1.2.3.51.2.24.4 | not-accessible | mandatory | |
| scalableComplexNodePortEntry OBJECT-TYPE Scalable complex node port information. | 1.3.6.1.4.1.2.3.51.2.24.4.1 | not-accessible | mandatory | |
| scalableComplexNodePortSlot OBJECT-TYPE The base slot number where the node exists in the chassis. | 1.3.6.1.4.1.2.3.51.2.24.4.1.1 | INTEGER | read-only | mandatory |
| scalableComplexNodePortNum OBJECT-TYPE The port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented as one more than the actual port number. | 1.3.6.1.4.1.2.3.51.2.24.4.1.2 | INTEGER | read-only | mandatory |
| scalableComplexNodePortRemChkSum OBJECT-TYPE The checksum of the remote port, used as a port identifier. | 1.3.6.1.4.1.2.3.51.2.24.4.1.3 | INTEGER | read-only | mandatory |
| scalableComplexNodePortRemNum OBJECT-TYPE The zero-based port number of the remote port. | 1.3.6.1.4.1.2.3.51.2.24.4.1.4 | INTEGER | read-only | mandatory |
| scalableComplexNodePortStatus OBJECT-TYPE The current status of the port. | 1.3.6.1.4.1.2.3.51.2.24.4.1.5 | INTEGER {disabled(1), enabled(2), unknown(255)} | read-only | mandatory |
| scalableComplexNodePortType OBJECT-TYPE The port type. | 1.3.6.1.4.1.2.3.51.2.24.4.1.6 | INTEGER {qpi(1), exa(2), unknown(255)} | read-only | mandatory |