MIBs Depot

BLADE-MIB

Registered at
1.3.6.1.4.1.2.3
Namespace
ibm
Source file
BLADE-MIB
Digest
sha256:37d40c091374e32b1d3ff51b08844398737d1e6cfc4d111c571bbdda2c32fffd

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BLADE-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgent

Textual conventions

NameOIDSyntaxAccessStatus
EntryStatus
type
InetAddressIPv6
TEXTUAL-CONVENTION
Represents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6
current

Objects

NameOIDSyntaxAccessStatus
ibm
OBJECT-IDENTITY
1.3.6.1.4.1.2
ibmAgents
OBJECT-IDENTITY
1.3.6.1.4.1.2.3
netfinitySupportProcessorAgent
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51
bladeCenterSnmpMIB
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2
monitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2
temperature
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1
planarTemp
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1.1
mmTemp
OBJECT-TYPE
Management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.1.2OCTET STRINGread-onlymandatory
ambientTemp
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.1.5
frontPanelTemp
OBJECT-TYPE
The front panel temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.1.5.1OCTET STRINGread-onlymandatory
frontPanel2Temp
OBJECT-TYPE
The front panel 2 temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter HT only
1.3.6.1.4.1.2.3.51.2.2.1.5.2OCTET STRINGread-onlymandatory
voltage
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.2
planarVolt
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.2.1
plus5Volt
OBJECT-TYPE
+5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.1OCTET STRINGread-onlymandatory
plus3Pt3Volt
OBJECT-TYPE
+3.3 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.2OCTET STRINGread-onlymandatory
plus12Volt
OBJECT-TYPE
+12 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.3OCTET STRINGread-onlymandatory
minus5Volt
OBJECT-TYPE
-5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.5OCTET STRINGread-onlymandatory
plus2Pt5Volt
OBJECT-TYPE
+2.5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.6OCTET STRINGread-onlymandatory
plus1Pt8Volt
OBJECT-TYPE
+1.8 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.2.1.8OCTET STRINGread-onlymandatory
blowers
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.3
blower1speed
OBJECT-TYPE
Blower 1 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.1OCTET STRINGread-onlymandatory
blower2speed
OBJECT-TYPE
Blower 2 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.2OCTET STRINGread-onlymandatory
blower3speed
OBJECT-TYPE
Blower 3 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.3OCTET STRINGread-onlymandatory
blower4speed
OBJECT-TYPE
Blower 4 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.4OCTET STRINGread-onlymandatory
blower1State
OBJECT-TYPE
The health state for blower 1. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.10INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
blower2State
OBJECT-TYPE
The health state for blower 2. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.11INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
blower3State
OBJECT-TYPE
The health state for blower 3. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.12INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
blower4State
OBJECT-TYPE
The health state for blower 4. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.13INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
blower1speedRPM
OBJECT-TYPE
Blower 1 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.20OCTET STRINGread-onlymandatory
blower2speedRPM
OBJECT-TYPE
Blower 2 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.21OCTET STRINGread-onlymandatory
blower3speedRPM
OBJECT-TYPE
Blower 3 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.22OCTET STRINGread-onlymandatory
blower4speedRPM
OBJECT-TYPE
Blower 4 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.23OCTET STRINGread-onlymandatory
blower1ControllerState
OBJECT-TYPE
The health state for the controller for blower 1. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.30INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
blower2ControllerState
OBJECT-TYPE
The health state for the controller for blower 2. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.31INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
blower3ControllerState
OBJECT-TYPE
The health state for the controller for blower 3. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.32INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
blower4ControllerState
OBJECT-TYPE
The health state for the controller for blower 4. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.33INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
blower1ExhaustTemp
OBJECT-TYPE
The exhaust temperature in degrees Celsius for blower 1. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.40OCTET STRINGread-onlymandatory
blower2ExhaustTemp
OBJECT-TYPE
The exhaust temperature in degrees Celsius for blower 2. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.41OCTET STRINGread-onlymandatory
blower3ExhaustTemp
OBJECT-TYPE
The exhaust temperature in degrees Celsius for blower 3. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.42OCTET STRINGread-onlymandatory
blower4ExhaustTemp
OBJECT-TYPE
The exhaust temperature in degrees Celsius for blower 4. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.43OCTET STRINGread-onlymandatory
powerModuleHealth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.4
powerModuleHealthTable
OBJECT-TYPE
Table of power module health information. Contains the power health information for each power module.
1.3.6.1.4.1.2.3.51.2.2.4.1not-accessiblemandatory
powerModuleHealthEntry
OBJECT-TYPE
Power Module health entry
1.3.6.1.4.1.2.3.51.2.2.4.1.1not-accessiblemandatory
powerModuleIndex
OBJECT-TYPE
Power module sequence index.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.1INTEGERread-onlymandatory
powerModuleExists
OBJECT-TYPE
Indicates whether the power module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.2INTEGER {false(0), true(1)}read-onlymandatory
powerModuleState
OBJECT-TYPE
The health state for the power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.3INTEGER {unknown(0), good(1), warning(2), notAvailable(3), critical(4)}read-onlymandatory
powerModuleDetails
OBJECT-TYPE
The details for this power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.4OCTET STRINGread-onlymandatory
spStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5
mmBistAndChassisStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5.2
bistSdram
OBJECT-TYPE
MM BIST DRAM test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.1INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistRs485Port1
OBJECT-TYPE
MM BIST RS 485 legacy test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.2INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistRs485Port2
OBJECT-TYPE
MM BIST RS 485 local bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.3INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistNvram
OBJECT-TYPE
MM BIST NVRAM test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.4INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistRtc
OBJECT-TYPE
MM BIST Real Time Clock test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.5INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistLocalI2CBus
OBJECT-TYPE
MM BIST Local I2C bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.7INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistPrimaryMainAppFlashImage
OBJECT-TYPE
MM BIST Primary Main Application Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.8INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistSecondaryMainAppFlashImage
OBJECT-TYPE
MM BIST Secondary Main Application test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.9INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistBootRomFlashImage
OBJECT-TYPE
MM BIST Boot Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.10INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistEthernetPort1
OBJECT-TYPE
MM BIST external ethernet port test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.11INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistEthernetPort2
OBJECT-TYPE
MM BIST internal ethernet port test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.12INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistInternalPCIBus
OBJECT-TYPE
MM BIST PCI bus test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.13INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistExternalI2CDevices
OBJECT-TYPE
MM BIST external I2C devices test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.14INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistUSBController
OBJECT-TYPE
MM BIST USB controller test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.15INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistVideoCompressorBoard
OBJECT-TYPE
MM BIST Video Compressor Board test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.16INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistRemoteVideo
OBJECT-TYPE
MM BIST Remote Video test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.17INTEGER {testSucceeded(0), testFailed(1)}read-onlydeprecated
bistPrimaryBus
OBJECT-TYPE
MM BIST primary mid-plane bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.18INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistInternalEthernetSwitch
OBJECT-TYPE
MM BIST internal external switch test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.19INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistVideoCapture
OBJECT-TYPE
MM BIST video capture test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.20INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistUSBKeyboardMouseEmulation
OBJECT-TYPE
MM BIST USB keyboard and mouse test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.21INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistUSBMassStorageEmulation
OBJECT-TYPE
MM BIST mass storage emulation test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.22INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistUSBKeyboardMouseFirmware
OBJECT-TYPE
MM BIST USB keyboard and mouse firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.23INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistUSBMassStorageFirmware
OBJECT-TYPE
MM BIST USB keyboard mouse firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.24INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistPrimaryCore
OBJECT-TYPE
MM BIST primary core test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.25INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistSecondaryCore
OBJECT-TYPE
MM BIST secondary core test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.26INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistInternalIOExpander
OBJECT-TYPE
MM BIST internal IO expander test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.27INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistRemoteControlFirmware
OBJECT-TYPE
MM BIST Remote Control firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.28INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
bistBladesInstalled
OBJECT-TYPE
The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.33OCTET STRINGread-onlymandatory
bistBladesCommunicating
OBJECT-TYPE
The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.49OCTET STRINGread-onlymandatory
bistBlowersInstalled
OBJECT-TYPE
The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.5.2.65OCTET STRINGread-onlymandatory
bistBlowersFunctional
OBJECT-TYPE
The blowers installed on the chassis that are functional. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.5.2.73OCTET STRINGread-onlymandatory
bistMediaTrayInstalled
OBJECT-TYPE
Indicates whether a media tray is installed on the chassis.
1.3.6.1.4.1.2.3.51.2.2.5.2.74INTEGER {no(0), yes(1)}read-onlymandatory
bistMediaTrayCommunicating
OBJECT-TYPE
Indicates whether a media tray is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.75INTEGER {no(0), yes(1)}read-onlymandatory
bistOtherMMInstalled
OBJECT-TYPE
Indicates whether a redundant MM is installed.
1.3.6.1.4.1.2.3.51.2.2.5.2.76INTEGER {no(0), yes(1)}read-onlymandatory
bistOtherMMCommunicating
OBJECT-TYPE
Indicates whether a redundant MM is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.77INTEGER {no(0), yes(1)}read-onlymandatory
bistPowerModulesInstalled
OBJECT-TYPE
The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.81OCTET STRINGread-onlymandatory
bistPowerModulesFunctional
OBJECT-TYPE
The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.2.89OCTET STRINGread-onlymandatory
bistSwitchModulesInstalled
OBJECT-TYPE
The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT.
1.3.6.1.4.1.2.3.51.2.2.5.2.97OCTET STRINGread-onlymandatory
bistSwitchModulesCommunicating
OBJECT-TYPE
The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT.
1.3.6.1.4.1.2.3.51.2.2.5.2.113OCTET STRINGread-onlymandatory
bistLastUpdate
OBJECT-TYPE
It is the time when the primary MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.2.200OCTET STRINGread-onlymandatory
rmmBistAndChassisStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.5.3
rbistRs485Port1
OBJECT-TYPE
Standby MM BIST RS 485 legacy test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.2INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistRs485Port2
OBJECT-TYPE
Standby MM BIST RS 485 local bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.3INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistRtc
OBJECT-TYPE
Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.5INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistLocalI2CBus
OBJECT-TYPE
Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.7INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistPrimaryMainAppFlashImage
OBJECT-TYPE
Standby MM BIST Primary Main Application Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.8INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistSecondaryMainAppFlashImage
OBJECT-TYPE
Standby MM BIST Secondary Main Application test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.9INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistBootRomFlashImage
OBJECT-TYPE
Standby MM BIST Boot Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.10INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistEthernetPort1
OBJECT-TYPE
Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.11INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistExternalI2CDevices
OBJECT-TYPE
Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.14INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistInternalEthernetSwitch
OBJECT-TYPE
Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.19INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistVideoCapture
OBJECT-TYPE
Standby MM BIST video capture test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.20INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistUSBKeyboardMouseEmulation
OBJECT-TYPE
Standby MM BIST USB keyboard and mouse test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.21INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistUSBMassStorageEmulation
OBJECT-TYPE
Standby MM BIST mass storage emulation test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.22INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistUSBKeyboardMouseFirmware
OBJECT-TYPE
Standby MM BIST USB keyboard and mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.23INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistUSBMassStorageFirmware
OBJECT-TYPE
Standby MM BIST USB keyboard mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.24INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistPrimaryCore
OBJECT-TYPE
Standby MM BIST primary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.25INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistSecondaryCore
OBJECT-TYPE
Standby MM BIST secondary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.26INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistInternalIOExpander
OBJECT-TYPE
Standby MM BIST internal IO expander test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.27INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistRemoteControlFirmware
OBJECT-TYPE
Standby MM BIST Remote Control firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.28INTEGER {testSucceeded(0), testFailed(1)}read-onlymandatory
rbistBladesInstalled
OBJECT-TYPE
The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.33OCTET STRINGread-onlymandatory
rbistBladesCommunicating
OBJECT-TYPE
The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.49OCTET STRINGread-onlymandatory
rbistBlowersInstalled
OBJECT-TYPE
The blowers that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.5.3.65OCTET STRINGread-onlymandatory
rbistBlowersFunctional
OBJECT-TYPE
The blowers installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.5.3.73OCTET STRINGread-onlymandatory
rbistMediaTrayInstalled
OBJECT-TYPE
Indicates whether a media tray was installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.74INTEGER {no(0), yes(1)}read-onlymandatory
rbistMediaTrayCommunicating
OBJECT-TYPE
Indicates whether a media tray was communicating when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.75INTEGER {no(0), yes(1)}read-onlymandatory
rbistOtherMMInstalled
OBJECT-TYPE
Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object.
1.3.6.1.4.1.2.3.51.2.2.5.3.76INTEGER {no(0), yes(1)}read-onlymandatory
rbistOtherMMCommunicating
OBJECT-TYPE
Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'.
1.3.6.1.4.1.2.3.51.2.2.5.3.77INTEGER {no(0), yes(1)}read-onlymandatory
rbistPowerModulesInstalled
OBJECT-TYPE
The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.81OCTET STRINGread-onlymandatory
rbistPowerModulesFunctional
OBJECT-TYPE
The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.2.5.3.89OCTET STRINGread-onlymandatory
rbistSwitchModulesInstalled
OBJECT-TYPE
The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT.
1.3.6.1.4.1.2.3.51.2.2.5.3.97OCTET STRINGread-onlymandatory
rbistSwitchModulesCommunicating
OBJECT-TYPE
The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT.
1.3.6.1.4.1.2.3.51.2.2.5.3.113OCTET STRINGread-onlymandatory
rbistUpdateTime
OBJECT-TYPE
It is the time when the standby MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3.200OCTET STRINGread-onlymandatory
rbistLastUpdatePrimary
OBJECT-TYPE
It is the time when the standby MM updated the last BIST results when it was still primary.
1.3.6.1.4.1.2.3.51.2.2.5.3.201OCTET STRINGread-onlymandatory
fanPack
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.6
fanPackTable
OBJECT-TYPE
Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.6.1not-accessiblemandatory
fanPackEntry
OBJECT-TYPE
Fan Pack entry
1.3.6.1.4.1.2.3.51.2.2.6.1.1not-accessiblemandatory
fanPackIndex
OBJECT-TYPE
Fan Pack sequence index.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.1INTEGERread-onlymandatory
fanPackExists
OBJECT-TYPE
Indicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.2INTEGER {false(0), true(1)}read-onlymandatory
fanPackState
OBJECT-TYPE
The health state for the fan pack. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.3INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
fanPackFanCount
OBJECT-TYPE
The number of fans in the fan pack.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.4INTEGER {unknown(255)}read-onlymandatory
fanPackAverageSpeed
OBJECT-TYPE
The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.5OCTET STRINGread-onlymandatory
fanPackAverageSpeedRPM
OBJECT-TYPE
The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.6OCTET STRINGread-onlymandatory
fanPackControllerState
OBJECT-TYPE
The health state for the controller for the fan pack. 0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error, 255 = unknown
1.3.6.1.4.1.2.3.51.2.2.6.1.1.7INTEGER {operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255)}read-onlymandatory
systemHealth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.7
systemHealthStat
OBJECT-TYPE
Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally.
1.3.6.1.4.1.2.3.51.2.2.7.1INTEGER {critical(0), nonCritical(2), systemLevel(4), normal(255)}read-onlymandatory
systemHealthSummaryTable
OBJECT-TYPE
Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2not-accessiblemandatory
systemHealthSummaryEntry
OBJECT-TYPE
System Health Summary entry NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1not-accessiblemandatory
systemHealthSummaryIndex
OBJECT-TYPE
System health summary index. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.1INTEGERread-onlymandatory
systemHealthSummarySeverity
OBJECT-TYPE
System health summary severity. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.2OCTET STRINGread-onlymandatory
systemHealthSummaryDescription
OBJECT-TYPE
System health summary description. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.3OCTET STRINGread-onlymandatory
systemHealthSummaryDateTime
OBJECT-TYPE
System health summary date time. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.4OCTET STRINGread-onlymandatory
leds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8
frontPanelLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.1
systemErrorLED
OBJECT-TYPE
Indicates whether the front panel system error LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.1INTEGER {off(0), on(1)}read-onlymandatory
informationLED
OBJECT-TYPE
Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.2INTEGER {off(0), on(1)}read-writemandatory
temperatureLED
OBJECT-TYPE
Indicates whether the front panel temperature LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.3INTEGER {off(0), on(1)}read-onlymandatory
identityLED
OBJECT-TYPE
Indicates whether the front panel identity LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.4INTEGER {off(0), on(1), blinking(2), notAvailable(3)}read-writemandatory
bladeLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.2
bladeLEDsTable
OBJECT-TYPE
Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more.
1.3.6.1.4.1.2.3.51.2.2.8.2.1not-accessiblemandatory
bladeLEDsEntry
OBJECT-TYPE
Blade system status entry
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1not-accessiblemandatory
ledBladeIndex
OBJECT-TYPE
Blade LED table index.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1INTEGERread-onlymandatory
ledBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
ledBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
ledBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)}read-onlymandatory
ledBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6OCTET STRINGread-onlymandatory
ledBladeSystemError
OBJECT-TYPE
Indicates whether the blade system error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7INTEGER {off(0), on(1)}read-onlymandatory
ledBladeInformation
OBJECT-TYPE
Indicates whether the blade information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8INTEGER {off(0), on(1)}read-writemandatory
ledBladeKVM
OBJECT-TYPE
Indicates whether the blade KVM LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.9INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
ledBladeMediaTray
OBJECT-TYPE
Indicates whether the blade media tray LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.10INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
ledBladeIdentity
OBJECT-TYPE
Indicates whether the blade identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11INTEGER {off(0), on(1), blinking(2)}read-writemandatory
bladeLEDsDetailsTable
OBJECT-TYPE
Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more.
1.3.6.1.4.1.2.3.51.2.2.8.2.2not-accessiblemandatory
bladeLEDsDetailsEntry
OBJECT-TYPE
Blade LEDs Details entry
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1not-accessiblemandatory
ledIndex
OBJECT-TYPE
The LED index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1INTEGERread-onlymandatory
ledBladeBayNumber
OBJECT-TYPE
The bay number of the main server blade that the LED is grouped into. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2OCTET STRINGread-onlymandatory
ledBladeComponentType
OBJECT-TYPE
Type of the component/subcomponent grouping for this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3OCTET STRINGread-onlymandatory
ledBladeLabel
OBJECT-TYPE
Text label for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4OCTET STRINGread-onlymandatory
ledBladeState
OBJECT-TYPE
Text description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
ledBladeLocation
OBJECT-TYPE
Location of this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6OCTET STRINGread-onlymandatory
telcoPanelLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.3
criticalLED
OBJECT-TYPE
Indicates whether the BladeCenter T Panel CRT (Critical) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.1INTEGER {off(0), on(1)}read-onlymandatory
majorLED
OBJECT-TYPE
Indicates whether the BladeCenter T Panel MJR (Major) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.2INTEGER {off(0), on(1)}read-onlymandatory
minorLED
OBJECT-TYPE
Indicates whether the BladeCenter T Panel MNR (Minor) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.3INTEGER {off(0), on(1)}read-onlymandatory
telcoIdentityLED
OBJECT-TYPE
Indicates whether the BladeCenter T Panel identity LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.4INTEGER {off(0), on(1), blinking(2), notAvailable(3)}read-writemandatory
telcoColorSel
OBJECT-TYPE
Indicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.5INTEGER {amber(0), red(1)}read-writemandatory
criticalityAssertionMode
OBJECT-TYPE
Indicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.6INTEGER {disable(0), enable(1)}read-writemandatory
smLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.4
smLEDsTable
OBJECT-TYPE
Table of switch module LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.4.1not-accessiblemandatory
smLEDsEntry
OBJECT-TYPE
Switch module LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1not-accessiblemandatory
ledSMIndex
OBJECT-TYPE
Switch module LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.1INTEGER (0..128)read-onlymandatory
ledSMLEDs
OBJECT-TYPE
A bitmap of LEDs information on the selected switch module. The bitmap is a string containing a list of 1's and 0's. Every 4 bytes are used to represent a led state. The first 64 bytes represent the status of the external LEDs while the last 64 bytes represent the status of the internal port connections from the switch module to blades. Each nibble of data is presented in the bitmap format (0000) and is encoded as followed - 0000: LED is not present - 0001: LED is off - 0010: LED is on NOTE: The data is read from left to right, starting out with blade server 1 and so on.
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.2OCTET STRING (SIZE(256))read-onlymandatory
blowerLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.5
blowerLEDsTable
OBJECT-TYPE
Table of blower LEDs information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.8.5.1not-accessiblemandatory
blowerLEDsEntry
OBJECT-TYPE
Blower LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1not-accessiblemandatory
ledBlowerIndex
OBJECT-TYPE
Blower LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1INTEGER (0..128)read-onlymandatory
ledBlowerId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)}read-onlymandatory
ledBlowerExists
OBJECT-TYPE
Indicates whether the blower specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledBlowerError
OBJECT-TYPE
Indicates whether the blower error LED is on, off, or not available.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4INTEGER {off(0), on(1), notAvailable(2)}read-onlymandatory
fanPackLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.6
fanPackLEDsTable
OBJECT-TYPE
Table of fan pack LEDs information. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.8.6.1not-accessiblemandatory
fanPackLEDsEntry
OBJECT-TYPE
Fan Pack LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1not-accessiblemandatory
ledFanPackIndex
OBJECT-TYPE
Fan Pack LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1INTEGER (0..128)read-onlymandatory
ledFanPackId
OBJECT-TYPE
The numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4)}read-onlymandatory
ledFanPackExists
OBJECT-TYPE
Indicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3INTEGER (0..128)read-onlymandatory
ledFanPackError
OBJECT-TYPE
Indicates whether the fan pack error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4INTEGER (0..128)read-onlymandatory
mtStatusLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.7
mtStatusLEDsTable
OBJECT-TYPE
Table of Media Tray Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1not-accessiblemandatory
mtStatusLEDsEntry
OBJECT-TYPE
Media Tray Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1not-accessiblemandatory
ledMediaTrayIndex
OBJECT-TYPE
Media Tray Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.1INTEGER (0..128)read-onlymandatory
ledMediaTrayId
OBJECT-TYPE
The numeric Media Tray ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.2INTEGER {topmediatray(1), botmediatray(2)}read-onlymandatory
ledMediaTrayExists
OBJECT-TYPE
Indicates whether the Media Tray exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledMediaTrayFault
OBJECT-TYPE
Indicates whether the Media Tray Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.5INTEGER {off(0), on(1)}read-onlymandatory
tapStatusLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.8
tapExists
OBJECT-TYPE
Indicates whether the Alarm Panel exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8.3INTEGER {false(0), true(1)}read-onlymandatory
tapFRRLED
OBJECT-TYPE
Indicates whether the Alarm Panel Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8.4INTEGER {off(0), on(1)}read-onlymandatory
tapFaultLED
OBJECT-TYPE
Indicates whether the Alarm Panel Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8.5INTEGER {off(0), on(1)}read-onlymandatory
ncStatusLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.9
ncStatusLEDsTable
OBJECT-TYPE
Table of Network Clock Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1not-accessibledeprecated
ncStatusLEDsEntry
OBJECT-TYPE
Network Clock Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1not-accessibledeprecated
ledNetworkClockIndex
OBJECT-TYPE
Network Clock Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.1INTEGER (0..128)read-onlydeprecated
ledNetworkClockId
OBJECT-TYPE
The numeric Network Clock ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.2INTEGER {networkclock1(1), networkclock2(2)}read-onlydeprecated
ledNetworkClockExists
OBJECT-TYPE
Indicates whether the Network Clock exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.3INTEGER {false(0), true(1)}read-onlydeprecated
ledNetworkClockFRR
OBJECT-TYPE
Indicates whether the Network Clock Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.4INTEGER {off(0), on(1)}read-onlydeprecated
ledNetworkClockFault
OBJECT-TYPE
Indicates whether the Network Clock Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.5INTEGER {off(0), on(1)}read-onlydeprecated
mxStatusLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.10
mxStatusLEDsTable
OBJECT-TYPE
Table of Multiplexer Expansion Module Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1not-accessiblemandatory
mxStatusLEDsEntry
OBJECT-TYPE
Multiplexer Expansion Module Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1not-accessiblemandatory
ledMuxIndex
OBJECT-TYPE
Multiplexer Expansion Module Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.1INTEGER (0..128)read-onlymandatory
ledMuxId
OBJECT-TYPE
The numeric Multiplexer Expansion Module ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.2INTEGER {mux1(1), mux2(2)}read-onlymandatory
ledMuxExists
OBJECT-TYPE
Indicates whether the Multiplexer Expansion Module exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledMuxFRR
OBJECT-TYPE
Indicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
ledMuxFault
OBJECT-TYPE
Indicates whether the Multiplexer Expansion Module Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.5INTEGER {off(0), on(1)}read-onlymandatory
storageLEDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.8.11
storageLEDsTable
OBJECT-TYPE
Table of storage module LEDs information. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1not-accessiblemandatory
storageLEDsEntry
OBJECT-TYPE
Storage Module LEDs information entry NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1not-accessiblemandatory
ledStorageIndex
OBJECT-TYPE
Storage Module LEDs table index. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.1INTEGERread-onlymandatory
ledStorageId
OBJECT-TYPE
The numeric storage module ID. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.2INTEGER {storage1(1), storage2(2)}read-onlymandatory
ledStorageExists
OBJECT-TYPE
Indicates whether the storage module specified exists or not. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
ledStorageError
OBJECT-TYPE
Indicates the status of the storage module error LED. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.4INTEGER {off(0), on(1), blinking(2)}read-onlymandatory
telcoSystemHealth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.9
telcoSystemHealthStat
OBJECT-TYPE
Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a non-recoverable service affecting condition has occurred that requires an immediate action. A value of 'major' indicates a critical service affecting condition has occurred that requires an urgent action. A value of 'minor' indicates a non-service affecting condition has occurred. Corrective action should be taken in order to prevent a more serious fault. A value of 'normal' indicates that the system is operating normally. Severity level with '-power' indicates the failure relates to the power resource. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.1INTEGER {minor(1), minor-power(2), major(3), major-power(4), critical(5), critical-power(6), normal(255)}read-onlymandatory
telcoSystemHealthSummaryTable
OBJECT-TYPE
Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter T only. NOTE: This table may contain one entry if no alarms are in progress. That one entry, if present, contains no alarms but a message of 'Good' in the severity object.
1.3.6.1.4.1.2.3.51.2.2.9.2not-accessiblemandatory
telcoSystemHealthSummaryEntry
OBJECT-TYPE
BladeCenter T System Health Summary entry. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1not-accessiblemandatory
telcoSystemHealthSummaryIndex
OBJECT-TYPE
BladeCenter T System Health Summary Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.1INTEGERread-onlymandatory
telcoSystemHealthSummarySeverity
OBJECT-TYPE
BladeCenter T System Health Summary Severity. The values and meanings are as follows: 0x06 Critical-Power 0x05 Critical 0x04 Major-Power 0x03 Major 0x02 Minor-Power 0x01 Minor 0xFF Normal NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'Good'.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.2OCTET STRINGread-onlymandatory
telcoSystemHealthSummaryDescription
OBJECT-TYPE
BladeCenter T System Health Summary Description. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.3OCTET STRINGread-onlymandatory
telcoSystemHealthSummaryEventName
OBJECT-TYPE
BladeCenter T System Health Summary Event Name. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.4INTEGERread-onlymandatory
telcoSystemHealthSummaryEventKeyID
OBJECT-TYPE
BladeCenter T System Health Summary Event Key ID. An octet string expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.5OCTET STRINGread-onlymandatory
telcoSystemHealthSummaryAcknowledge
OBJECT-TYPE
BladeCenter T System Health Summary Acknowledge. Indicates whether the alarm event is acknowledged or unacknowledged. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.6INTEGER {unacknowledged(0), acknowledged(1)}read-onlymandatory
telcoSystemHealthSummaryAssertTime
OBJECT-TYPE
BladeCenter T System Health Summary Assert Time. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.7OCTET STRINGread-onlymandatory
fuelGauge
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10
fuelGaugeInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.1
fuelGaugeTable
OBJECT-TYPE
Table of Fuel Gauge information.
1.3.6.1.4.1.2.3.51.2.2.10.1.1not-accessiblemandatory
fuelGaugeEntry
OBJECT-TYPE
Fuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1not-accessiblemandatory
fuelGaugeIndex
OBJECT-TYPE
Fuel Gauge Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1INTEGERread-onlymandatory
fuelGaugePowerDomainNumber
OBJECT-TYPE
Fuel Gauge Table Power Domain Number.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2INTEGER {powerDomain1(1), powerDomain2(2)}read-onlymandatory
fuelGaugeStatus
OBJECT-TYPE
Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3OCTET STRINGread-onlymandatory
fuelGaugeFirstPowerModule
OBJECT-TYPE
Fuel Gauge Table First Power Module capacity in Watts in the power domain. NOTE: First power module in power domain 1 and 2 is in bay 1 and 3 respectively.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4OCTET STRINGread-onlymandatory
fuelGaugeSecondPowerModule
OBJECT-TYPE
Fuel Gauge Table Second Power Module capacity in Watts in the power domain. NOTE: Second power module in power domain 1 and 2 is in bay 2 and 4 respectively.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5OCTET STRINGread-onlymandatory
fuelGaugePowerManagementPolicySetting
OBJECT-TYPE
Fuel Gauge Table for the Power Management Policy Setting for each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. In addition, note that the first three enumerated choices above are referred to with updated nomenclature, as follows: redundantWithoutPerformanceImpact(0) equals Redundant Power Modules redundantWithPerformanceImpact(1) equals Power Modules with Blade Throttling Allowed nonRedundant(2) equals Basic Power Management
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6INTEGER {redundantWithoutPerformanceImpact(0), redundantWithPerformanceImpact(1), nonRedundant(2), redundantACPowerSource(3), acPowerSourceWithBladeThrottlingAllowed(4), notApplicable(255)}read-onlymandatory
fuelGaugeTotalPower
OBJECT-TYPE
This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7OCTET STRINGread-onlymandatory
fuelGaugeAllocatedPower
OBJECT-TYPE
This field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and 4 (Powered on or standby). 3) Power is reserved for each installed Blade. Blades in a standby state (not powered on) will reserve a certain amount power. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8OCTET STRINGread-onlymandatory
fuelGaugeRemainingPower
OBJECT-TYPE
This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9OCTET STRINGread-onlymandatory
fuelGaugePowerInUsed
OBJECT-TYPE
This field displays the total power being used in each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10OCTET STRINGread-onlymandatory
powerDomain1
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.2
powerDomain1Table
OBJECT-TYPE
Table of Power Domain 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.2.1not-accessiblemandatory
powerDomain1Entry
OBJECT-TYPE
Fuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1not-accessiblemandatory
pd1Index
OBJECT-TYPE
Power Domain 1 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1INTEGERread-onlymandatory
pd1BayNumber
OBJECT-TYPE
Power Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), managementModuleBay1(5), managementModuleBay2(6), switchModuleBay1(7), switchModuleBay2(8), switchModuleBay3(9), switchModuleBay4(10), serverBladeBay1(11), serverBladeBay2(12), serverBladeBay3(13), serverBladeBay4(14), serverBladeBay5(15), serverBladeBay6(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay1(17), serverBladeBay2(18), serverBladeBay3(19), serverBladeBay4(20), serverBladeBay5(21), serverBladeBay6(22), serverBladeBay7(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), blowerBay3(5) (if Power Domain 2 is not available), blowerBay4(6) (if Power Domain 2 is not available), managementModuleBay1(7), managementModuleBay2(8), switchModuleBay1(9), switchModuleBay2(10), switchModuleBay3(11), switchModuleBay4(12), serverBladeBay1(13), serverBladeBay2(14), serverBladeBay3(15), serverBladeBay4(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter HT: notApplicable(1), mediatrayBay1(2), mediatrayBay2(3), fanPackBay1(4), fanPackBay2(5), fanPackBay3(6), fanPackBay4(7), blowerBay1(8), blowerBay2(9), blowerBay3(10), blowerBay4(11), networkclockBay1(12), networkclockBay2(13), midplaneelectroBay1(14), midplaneelectroBay2(15), notApplicable(16), managementModuleBay1(17), managementModuleBay2(18), ioModuleBay1(19), ioModuleBay2(20), ioModuleBay3(21), ioModuleBay4(22), serverBladeBay1(23), serverBladeBay2(24), serverBladeBay3(25), serverBladeBay4(26), serverBladeBay5(27), serverBladeBay6(28), notApplicable(29) The following Bay Number IDs are used in the BladeCenter S: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), blowerBay1(7), blowerBay2(8), blowerBay3(9), blowerBay4(10), storageModuleBay1(11), storageModuleBay2(12), managementModuleBay(13), ioModuleBay1(14), ioModuleBay2(15), ioModuleBay3(16), ioModuleBay4(17), serverBladeBay1(18), serverBladeBay2(19), serverBladeBay3(20), serverBladeBay4(21), serverBladeBay5(22), serverBladeBay6(23), notApplicable(24)
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2OCTET STRINGread-onlymandatory
pd1BladePrimarySlot
OBJECT-TYPE
Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd1ModuleStatus
OBJECT-TYPE
Power Domain 1 Table Module Throttle Status.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)}read-onlymandatory
pd1ModuleName
OBJECT-TYPE
Power Domain 1 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5OCTET STRINGread-onlymandatory
pd1ModuleState
OBJECT-TYPE
Power Domain 1 Table Module State.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)}read-onlymandatory
pd1ModuleAllocatedPowerCurrent
OBJECT-TYPE
Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7OCTET STRINGread-onlymandatory
pd1ModuleAllocatedPowerMax
OBJECT-TYPE
Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8OCTET STRINGread-onlymandatory
pd1ModuleAllocatedPowerMin
OBJECT-TYPE
Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9OCTET STRINGread-onlymandatory
pd1ModuleCPUDutyCycles
OBJECT-TYPE
Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10OCTET STRINGread-onlymandatory
pd1ModuleThrottle
OBJECT-TYPE
Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd1ModulePowerCapabilities
OBJECT-TYPE
Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)}read-onlymandatory
pd1ModuleMeasuredOrStatic
OBJECT-TYPE
Power Domain 1 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13INTEGER {static(0), measured(1), notApplicable(255)}read-onlymandatory
powerDomain1PowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.2.3
pd1PowerTrendingPeriod
OBJECT-TYPE
Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
pd1PowerTrendingSampleTable
OBJECT-TYPE
Table of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10not-accessiblemandatory
pd1PowerTrendingSampleEntry
OBJECT-TYPE
Power Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1not-accessiblemandatory
pd1PowerTrendingSampleIndex
OBJECT-TYPE
Power Domain 1 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1INTEGERread-onlymandatory
pd1PowerTrendingSampleTimeStamp
OBJECT-TYPE
Power Domain 1 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2OCTET STRINGread-onlymandatory
pd1PowerTrendingSampleAve
OBJECT-TYPE
Power Domain 1 Power Trending Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3OCTET STRINGread-onlymandatory
powerDomain2
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.3
powerDomain2Table
OBJECT-TYPE
Table of Power Domain 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.3.1not-accessiblemandatory
powerDomain2Entry
OBJECT-TYPE
Fuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1not-accessiblemandatory
pd2Index
OBJECT-TYPE
Power Domain 2 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.1INTEGERread-onlymandatory
pd2BayNumber
OBJECT-TYPE
Power Domain 2 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: serverBladeBay7(1), serverBladeBay8(2), serverBladeBay9(3), serverBladeBay10(4), serverBladeBay11(5), serverBladeBay12(6), serverBladeBay13(7), serverBladeBay14(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay8(17), serverBladeBay9(18), serverBladeBay10(19), serverBladeBay11(20), serverBladeBay12(21), serverBladeBay13(22), serverBladeBay14(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: blowerBay3(1), blowerBay4(2), serverBladeBay5(3), serverBladeBay6(4), serverBladeBay7(5), serverBladeBay8(6), notApplicable(7), notApplicable(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter HT: fanPackBay1(1), fanPackBay2(2), fanPackBay3(3), fanPackBay4(4), blowerBay1(5), blowerBay2(6), blowerBay3(7), blowerBay4(8), ioModuleBay7(9), ioModuleBay8(10), ioModuleBay9(11), ioModuleBay10(12), serverBladeBay7(13), serverBladeBay8(14), serverBladeBay9(15), serverBladeBay10(16), serverBladeBay11(17), serverBladeBay12(18), notApplicable(19)
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.2OCTET STRINGread-onlymandatory
pd2BladePrimarySlot
OBJECT-TYPE
Power Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd2ModuleStatus
OBJECT-TYPE
Power Domain 2 Table Module throttle status.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.4INTEGER {insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255)}read-onlymandatory
pd2ModuleName
OBJECT-TYPE
Power Domain 2 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.5OCTET STRINGread-onlymandatory
pd2ModuleState
OBJECT-TYPE
Power Domain 2 Table Power State.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.6INTEGER {standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255)}read-onlymandatory
pd2ModuleAllocatedPowerCurrent
OBJECT-TYPE
Power Domain 2 Table Allocated Power Current indicates the current power allocation for the module. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.7OCTET STRINGread-onlymandatory
pd2ModuleAllocatedPowerMax
OBJECT-TYPE
Power Domain 2 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.8OCTET STRINGread-onlymandatory
pd2ModuleAllocatedPowerMin
OBJECT-TYPE
Power Domain 2 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.9OCTET STRINGread-onlymandatory
pd2ModuleCPUDutyCycles
OBJECT-TYPE
Power Domain 2 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.10OCTET STRINGread-onlymandatory
pd2ModuleThrottle
OBJECT-TYPE
Power Domain 2 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.11INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
pd2ModulePowerCapabilities
OBJECT-TYPE
Power Domain 2 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.12INTEGER {noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255)}read-onlymandatory
pd2ModuleMeasuredOrStatic
OBJECT-TYPE
Power Domain 2 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.13INTEGER {static(0), measured(1), notApplicable(255)}read-onlymandatory
powerDomain2PowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.3.3
pd2PowerTrendingPeriod
OBJECT-TYPE
Specify time period for power domain 2 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
pd2PowerTrendingSampleTable
OBJECT-TYPE
Table of Power Domain 2 Power Trending Sample Information.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10not-accessiblemandatory
pd2PowerTrendingSampleEntry
OBJECT-TYPE
Power Domain 2 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1not-accessiblemandatory
pd2PowerTrendingSampleIndex
OBJECT-TYPE
Power Domain 2 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.1INTEGERread-onlymandatory
pd2PowerTrendingSampleTimeStamp
OBJECT-TYPE
Power Domain 2 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.2OCTET STRINGread-onlymandatory
pd2PowerTrendingSampleAve
OBJECT-TYPE
Power Domain 2 Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.3OCTET STRINGread-onlymandatory
moduleInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4
bladeDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.1
bladeDetailsTable
OBJECT-TYPE
Table of Blade Module Details.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1not-accessiblemandatory
bladeDetailsEntry
OBJECT-TYPE
Blade Module Details entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1not-accessiblemandatory
bladeDetailsIndex
OBJECT-TYPE
Blade Module Details Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1INTEGERread-onlymandatory
bladeDetailsId
OBJECT-TYPE
Blade Module Details Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeDetailsMaxPowerConfig
OBJECT-TYPE
Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3INTEGERread-writemandatory
bladeDetailsEffectiveClockRate
OBJECT-TYPE
Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4OCTET STRINGread-onlymandatory
bladeDetailsMaximumClockRate
OBJECT-TYPE
Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5OCTET STRINGread-onlymandatory
bladeDetailsPowerSaverMode
OBJECT-TYPE
When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsDynamicPowerSaver
OBJECT-TYPE
When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsDynamicPowerFavorPerformanceOverPower
OBJECT-TYPE
When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8INTEGER {disable(0), enable(1), notApplicable(255)}read-writemandatory
bladeDetailsPowerControl
OBJECT-TYPE
This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9INTEGER {none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255)}read-writemandatory
bladePowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3
bladePowerTrendingPeriod
OBJECT-TYPE
Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
bladePowerTrendingBladeId
OBJECT-TYPE
Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-writemandatory
bladePowerTrendingSampleTable
OBJECT-TYPE
Table of Blade Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10not-accessiblemandatory
bladePowerTrendingSampleEntry
OBJECT-TYPE
Blade Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1not-accessiblemandatory
bladePowerTrendingSampleIndex
OBJECT-TYPE
Blade Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1INTEGERread-onlymandatory
bladePowerTrendingSampleId
OBJECT-TYPE
Blade Module Power Trending Sample Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladePowerTrendingSampleTimeStamp
OBJECT-TYPE
Blade Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3OCTET STRINGread-onlymandatory
bladePowerTrendingSampleMax
OBJECT-TYPE
Blade Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4OCTET STRINGread-onlymandatory
bladePowerTrendingSampleMin
OBJECT-TYPE
Blade Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5OCTET STRINGread-onlymandatory
bladePowerTrendingSampleAve
OBJECT-TYPE
Blade Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6OCTET STRINGread-onlymandatory
switchDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.2
switchPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3
switchPowerTrendingPeriod
OBJECT-TYPE
Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
switchPowerTrendingSwitchId
OBJECT-TYPE
Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-writemandatory
switchPowerTrendingSampleTable
OBJECT-TYPE
Table of Switch Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10not-accessiblemandatory
switchPowerTrendingSampleEntry
OBJECT-TYPE
Switch Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1not-accessiblemandatory
switchPowerTrendingSampleIndex
OBJECT-TYPE
Switch Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1INTEGERread-onlymandatory
switchPowerTrendingSampleId
OBJECT-TYPE
Switch Module Power Trending Sample Table Switch Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
switchPowerTrendingSampleTimeStamp
OBJECT-TYPE
Switch Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3OCTET STRINGread-onlymandatory
switchPowerTrendingSampleMax
OBJECT-TYPE
Switch Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4OCTET STRINGread-onlymandatory
switchPowerTrendingSampleMin
OBJECT-TYPE
Switch Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5OCTET STRINGread-onlymandatory
switchPowerTrendingSampleAve
OBJECT-TYPE
Switch Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6OCTET STRINGread-onlymandatory
blowerDetails
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.3
blowerPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3
blowerPowerTrendingPeriod
OBJECT-TYPE
Specify time period for blower module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blower Module. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
blowerPowerTrendingBlowerId
OBJECT-TYPE
Blower Module Power Trending Blower Id. NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)}read-writemandatory
blowerPowerTrendingSampleTable
OBJECT-TYPE
Table of Blower Module Power Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10not-accessiblemandatory
blowerPowerTrendingSampleEntry
OBJECT-TYPE
Blower Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1not-accessiblemandatory
blowerPowerTrendingSampleIndex
OBJECT-TYPE
Blower Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1INTEGERread-onlymandatory
blowerPowerTrendingSampleId
OBJECT-TYPE
Blower Module Power Trending Sample Table Blower Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)}read-onlymandatory
blowerPowerTrendingSampleTimeStamp
OBJECT-TYPE
Blower Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3OCTET STRINGread-onlymandatory
blowerPowerTrendingSampleMax
OBJECT-TYPE
Blower Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4OCTET STRINGread-onlymandatory
blowerPowerTrendingSampleMin
OBJECT-TYPE
Blower Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5OCTET STRINGread-onlymandatory
blowerPowerTrendingSampleAve
OBJECT-TYPE
Blower Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6OCTET STRINGread-onlymandatory
chassisInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5
chassisConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.1
chassisTotalDCPowerAvailable
OBJECT-TYPE
Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.1OCTET STRINGread-onlymandatory
chassisTotalACPowerInUsed
OBJECT-TYPE
Chassis total AC power being used, which displays the total AC power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis oooling devices) for the chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.2OCTET STRINGread-onlymandatory
chassisTotalThermalOutput
OBJECT-TYPE
Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total AC power in use. (1 Watt = 3.412 BTU/hour).
1.3.6.1.4.1.2.3.51.2.2.10.5.1.3OCTET STRINGread-onlymandatory
chassisTrendingSampleInterval
OBJECT-TYPE
Chassis Power and Thermal Trending Sample Interval. 0 means no trending. the minimum interval is 10 minutes and the maximum is 60 minutes, in 5 minute increments.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.4INTEGERread-writemandatory
chassisPowerService
OBJECT-TYPE
The chassis power service mode. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.5INTEGER {volt110(1), volt220(2), notAvailable(255)}read-onlymandatory
chassisPowerTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.3
chassisPowerTrendingPeriod
OBJECT-TYPE
Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
chassisPowerTrendingSampleTable
OBJECT-TYPE
Table of Chassis Power Trending Sample Information in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10not-accessiblemandatory
chassisPowerTrendingSampleEntry
OBJECT-TYPE
Chassis Power Trending Sample entry in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1not-accessiblemandatory
chassisPowerTrendingSampleIndex
OBJECT-TYPE
Chassis Power Trending Sample Index in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1INTEGERread-onlymandatory
chassisPowerTrendingSampleTimeStamp
OBJECT-TYPE
Chassis Power Trending Sample Timestamp in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2OCTET STRINGread-onlymandatory
chassisPowerTrendingSampleAve
OBJECT-TYPE
Chassis Power Trending Sample Average Power in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3OCTET STRINGread-onlymandatory
chassisThermalTrending
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.5.5
chassisThermalTrendingPeriod
OBJECT-TYPE
Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.1INTEGER {lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3)}read-writemandatory
mt1ThermalTrendingTable
OBJECT-TYPE
Table of Media Tray 1 Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10not-accessiblemandatory
mt1ThermalTrendingEntry
OBJECT-TYPE
Media Tray 1 Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1not-accessiblemandatory
mt1ThermalTrendingIndex
OBJECT-TYPE
Media Tray 1 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1INTEGERread-onlymandatory
mt1ThermalTrendingTimeStamp
OBJECT-TYPE
Media Tray 1 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2OCTET STRINGread-onlymandatory
mt1ThermalTrendingTemperature
OBJECT-TYPE
Media Tray 1 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3OCTET STRINGread-onlymandatory
mt2ThermalTrendingTable
OBJECT-TYPE
Table of Media Tray 2 Thermal Trending Information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15not-accessiblemandatory
mt2ThermalTrendingEntry
OBJECT-TYPE
Media Tray 2 Thermal Trending entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1not-accessiblemandatory
mt2ThermalTrendingIndex
OBJECT-TYPE
Media Tray 2 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.1INTEGERread-onlymandatory
mt2ThermalTrendingTimeStamp
OBJECT-TYPE
Media Tray 2 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.2OCTET STRINGread-onlymandatory
mt2ThermalTrendingTemperature
OBJECT-TYPE
Media Tray 2 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.3OCTET STRINGread-onlymandatory
blower1ThermalTrendingTable
OBJECT-TYPE
Table of Blower 1 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20not-accessiblemandatory
blower1ThermalTrendingEntry
OBJECT-TYPE
Blower 1 Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1not-accessiblemandatory
blower1ThermalTrendingIndex
OBJECT-TYPE
Blower 1 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.1INTEGERread-onlymandatory
blower1ThermalTrendingTimeStamp
OBJECT-TYPE
Blower 1 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.2OCTET STRINGread-onlymandatory
blower1ThermalTrendingTemperature
OBJECT-TYPE
Blower 1 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.3OCTET STRINGread-onlymandatory
blower2ThermalTrendingTable
OBJECT-TYPE
Table of Blower 2 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30not-accessiblemandatory
blower2ThermalTrendingEntry
OBJECT-TYPE
Blower Thermal 2 Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1not-accessiblemandatory
blower2ThermalTrendingIndex
OBJECT-TYPE
Blower 2 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.1INTEGERread-onlymandatory
blower2ThermalTrendingTimeStamp
OBJECT-TYPE
Blower 2 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.2OCTET STRINGread-onlymandatory
blower2ThermalTrendingTemperature
OBJECT-TYPE
Blower 2 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.3OCTET STRINGread-onlymandatory
blower3ThermalTrendingTable
OBJECT-TYPE
Table of Blower 3 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40not-accessiblemandatory
blower3ThermalTrendingEntry
OBJECT-TYPE
Blower 3 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1not-accessiblemandatory
blower3ThermalTrendingIndex
OBJECT-TYPE
Blower 3 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.1INTEGERread-onlymandatory
blower3ThermalTrendingTimeStamp
OBJECT-TYPE
Blower 3 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.2OCTET STRINGread-onlymandatory
blower3ThermalTrendingTemperature
OBJECT-TYPE
Blower 3 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.3OCTET STRINGread-onlymandatory
blower4ThermalTrendingTable
OBJECT-TYPE
Table of Blower 4 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50not-accessiblemandatory
blower4ThermalTrendingEntry
OBJECT-TYPE
Blower 4 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1not-accessiblemandatory
blower4ThermalTrendingIndex
OBJECT-TYPE
Blower 4 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.1INTEGERread-onlymandatory
blower4ThermalTrendingTimeStamp
OBJECT-TYPE
Blower 4 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.2OCTET STRINGread-onlymandatory
blower4ThermalTrendingTemperature
OBJECT-TYPE
Blower 4 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.3OCTET STRINGread-onlymandatory
powerPolicyInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.10.6
powerPolicyTable
OBJECT-TYPE
Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain.
1.3.6.1.4.1.2.3.51.2.2.10.6.1not-accessiblemandatory
powerPolicyEntry
OBJECT-TYPE
Power Policy Entry
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1not-accessiblemandatory
powerPolicyIndex
OBJECT-TYPE
The unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1INTEGERread-onlymandatory
powerPolicyPowerDomainNumber
OBJECT-TYPE
The power domain number which this row is associated with.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2INTEGER {powerDomain1(1), powerDomain2(2)}read-onlymandatory
powerPolicyName
OBJECT-TYPE
The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single AC power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for AC power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. AC Power Source Redundancy Intended for dual AC power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual AC power sources, one AC power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. AC Power Source Redundancy with Blade Throttling Allowed Very similar to the AC Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one AC power source fails.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3OCTET STRINGread-onlymandatory
powerPolicyPwrSupplyFailureLimit
OBJECT-TYPE
The maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4INTEGERread-onlymandatory
powerPolicyMaxPowerLimit
OBJECT-TYPE
The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5INTEGERread-onlymandatory
powerPolicyEstimatedUtilization
OBJECT-TYPE
The estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6INTEGERread-onlymandatory
powerPolicyActivate
OBJECT-TYPE
When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the AMM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
frontbezel
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.12
frontbezelExists
OBJECT-TYPE
Indicates whether the front bezel is installed or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.12.1INTEGER {false(0), true(1)}read-onlymandatory
users
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.17
mmUsers
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.17.1
currentlyLoggedInTable
OBJECT-TYPE
Table of MM users currently logged in. NOTE: This MIB object is for AMM only.
1.3.6.1.4.1.2.3.51.2.2.17.1.1not-accessiblemandatory
currentlyLoggedInEntry
OBJECT-TYPE
MM users currently logged in entries. NOTE: This MIB object is for AMM only.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1not-accessiblemandatory
currentlyLoggedInEntryIndex
OBJECT-TYPE
Index for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1INTEGER (0..255)read-onlymandatory
currentlyLoggedInEntryUserId
OBJECT-TYPE
Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2OCTET STRING (SIZE(0..64))read-onlymandatory
currentlyLoggedInEntryAccMethod
OBJECT-TYPE
Access method for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3OCTET STRING (SIZE(0..32))read-onlymandatory
monitorThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.20
voltageThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.20.2
voltageThresholdsTable
OBJECT-TYPE
Table of voltage threshold entries. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.20.2.1not-accessiblemandatory
voltageThresholdsEntry
OBJECT-TYPE
Voltage threshold entries. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1not-accessiblemandatory
voltageThresholdEntryIndex
OBJECT-TYPE
Index for voltage threshold entry.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.1INTEGER (0..255)read-onlymandatory
voltageThresholdEntryName
OBJECT-TYPE
Voltage threshold entry null terminated string that contains the power supply's name, for example '+5V'.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
voltageThresholdEntryCurrentValue
OBJECT-TYPE
Voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.3OCTET STRINGread-onlymandatory
voltageThresholdEntryWarningHighValue
OBJECT-TYPE
Voltage threshold reading expressed in Volts(V). If the voltage rises above this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6OCTET STRINGread-onlymandatory
voltageThresholdEntryWarningResetHighValue
OBJECT-TYPE
Voltage threshold reading expressed in Volts(V). If the voltage rises above this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.7OCTET STRINGread-onlymandatory
voltageThresholdEntryWarningLowValue
OBJECT-TYPE
Voltage threshold reading expressed in Volts(V). If the voltage drops below this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.10OCTET STRINGread-onlymandatory
voltageThresholdEntryWarningResetLowValue
OBJECT-TYPE
Voltage threshold reading expressed in Volts(V). If the voltage drops below this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.11OCTET STRINGread-onlymandatory
vpdInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21
chassisVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.1
bladeCenterVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.1.1
bladeCenterVpdMachineType
OBJECT-TYPE
Machine type VPD information (from System BIOS). This field must be four alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.1OCTET STRINGread-writemandatory
bladeCenterVpdMachineModel
OBJECT-TYPE
Machine model VPD information (from System BIOS). This field must be three alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.2OCTET STRINGread-writemandatory
bladeCenterSerialNumber
OBJECT-TYPE
Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.3OCTET STRINGread-writemandatory
bladeCenterUUID
OBJECT-TYPE
Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.4OCTET STRINGread-writemandatory
bladeCenterManufacturingId
OBJECT-TYPE
Machine chassis manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.5OCTET STRINGread-onlymandatory
bladeCenterHardwareRevision
OBJECT-TYPE
Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.6INTEGERread-onlymandatory
bladeCenterFruNumber
OBJECT-TYPE
Machine chassis FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.7OCTET STRINGread-onlymandatory
bladeCenterManufDate
OBJECT-TYPE
Machine chassis manufacture date.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.8OCTET STRINGread-onlymandatory
bladeCenterPartNumber
OBJECT-TYPE
Machine chassis part number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.9OCTET STRINGread-onlymandatory
bladeCenterFruSerial
OBJECT-TYPE
Machine chassis FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.10OCTET STRINGread-onlymandatory
bladeCenterManufacturingIDNumber
OBJECT-TYPE
Machine chassis manufacturer ID Number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.11OCTET STRINGread-onlymandatory
bladeCenterProductId
OBJECT-TYPE
Machine chassis product ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.12OCTET STRINGread-onlymandatory
bladeCenterSubManufacturerId
OBJECT-TYPE
Machine chassis subsystem manufacturer.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.13OCTET STRINGread-onlymandatory
bladeCenterClei
OBJECT-TYPE
Machine chassis Common Language Equipment Identification (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.1.1.14OCTET STRINGread-onlymandatory
bladeCenterDirectSerialAttach
OBJECT-TYPE
Presence of the Direct Serial Attach Module. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.15INTEGER {false(0), true(1)}read-onlymandatory
bladeCenterHardwareRevisionString
OBJECT-TYPE
Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.16OCTET STRINGread-onlymandatory
mmHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.2
mmHardwareVpdTable
OBJECT-TYPE
Table of the management module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1not-accessiblemandatory
mmHardwareVpdEntry
OBJECT-TYPE
Management module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1not-accessiblemandatory
mmHardwareVpdIndex
OBJECT-TYPE
Management module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1INTEGERread-onlymandatory
mmHardwareVpdBayNumber
OBJECT-TYPE
Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2OCTET STRINGread-onlymandatory
mmHardwareVpdManufacturingId
OBJECT-TYPE
Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3OCTET STRINGread-onlymandatory
mmHardwareVpdFruNumber
OBJECT-TYPE
Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4OCTET STRINGread-onlymandatory
mmHardwareVpdHardwareRevision
OBJECT-TYPE
Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5INTEGERread-onlymandatory
mmHardwareVpdUuid
OBJECT-TYPE
Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6OCTET STRINGread-onlymandatory
mmHardwareVpdManufDate
OBJECT-TYPE
Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7OCTET STRINGread-onlymandatory
mmHardwareVpdPartNumber
OBJECT-TYPE
Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8OCTET STRINGread-onlymandatory
mmHardwareVpdFruSerial
OBJECT-TYPE
Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9OCTET STRINGread-onlymandatory
mmHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10OCTET STRINGread-onlymandatory
mmHardwareVpdProductId
OBJECT-TYPE
Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11OCTET STRINGread-onlymandatory
mmHardwareVpdSubManufacturerId
OBJECT-TYPE
Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12OCTET STRINGread-onlymandatory
mmHardwareVpdClei
OBJECT-TYPE
Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13OCTET STRINGread-onlymandatory
mmHardwareVpdHardwareRevisionString
OBJECT-TYPE
Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14OCTET STRINGread-onlymandatory
mmInpHardwareVpdTable
OBJECT-TYPE
Table of the management module interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2not-accessiblemandatory
mmInpHardwareVpdEntry
OBJECT-TYPE
Management module Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1not-accessiblemandatory
mmInpHardwareVpdIndex
OBJECT-TYPE
Management module Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.1INTEGERread-onlymandatory
mmInpHardwareVpdBayNumber
OBJECT-TYPE
Management module Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.2OCTET STRINGread-onlymandatory
mmInpHardwareVpdManufacturingId
OBJECT-TYPE
Management module Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.3OCTET STRINGread-onlymandatory
mmInpHardwareVpdFruNumber
OBJECT-TYPE
Management module Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.4OCTET STRINGread-onlymandatory
mmInpHardwareVpdHardwareRevision
OBJECT-TYPE
Management module Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.5INTEGERread-onlymandatory
mmInpHardwareVpdUuid
OBJECT-TYPE
Management module Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.6OCTET STRINGread-onlymandatory
mmInpHardwareVpdManufDate
OBJECT-TYPE
Management module Interposer hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.7OCTET STRINGread-onlymandatory
mmInpHardwareVpdPartNumber
OBJECT-TYPE
Management module Interposer hardware VPD Part number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.8OCTET STRINGread-onlymandatory
mmInpHardwareVpdFruSerial
OBJECT-TYPE
Management module Interposer hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.9OCTET STRINGread-onlymandatory
mmInpHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Management module Interposer hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.10OCTET STRINGread-onlymandatory
mmInpHardwareVpdProductId
OBJECT-TYPE
Management module Interposer hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.11OCTET STRINGread-onlymandatory
mmInpHardwareVpdSubManufacturerId
OBJECT-TYPE
Management module Interposer hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.12OCTET STRINGread-onlymandatory
mmInpHardwareVpdClei
OBJECT-TYPE
Management module Interposer hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.13OCTET STRINGread-onlymandatory
mmInpHardwareVpdHardwareRevisionString
OBJECT-TYPE
Management module Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.14OCTET STRINGread-onlymandatory
mmFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.3
mmMainApplVpdTable
OBJECT-TYPE
Table of MM Firmware VPD.
1.3.6.1.4.1.2.3.51.2.2.21.3.1not-accessiblemandatory
mmMainApplVpdEntry
OBJECT-TYPE
MM Firmware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1not-accessiblemandatory
mmMainApplVpdIndex
OBJECT-TYPE
Firmware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1INTEGERread-onlymandatory
mmMainApplVpdName
OBJECT-TYPE
Firmware VPD name description. 'AMM firmware' indicates the running firmware of the MM. 'AMM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2OCTET STRINGread-onlymandatory
mmMainApplVpdBuildId
OBJECT-TYPE
Firmware VPD build identification.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3OCTET STRINGread-onlymandatory
mmMainApplVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4OCTET STRINGread-onlymandatory
mmMainApplVpdFilename
OBJECT-TYPE
Firmware VPD file name.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5OCTET STRINGread-onlymandatory
mmMainApplVpdBuildDate
OBJECT-TYPE
Firmware VPD build date.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6OCTET STRINGread-onlymandatory
mmBootROMVpdTable
OBJECT-TYPE
Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2not-accessibledeprecated
mmBootROMVpdEntry
OBJECT-TYPE
MM Firmware VPD entry. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1not-accessibledeprecated
mmBootROMVpdIndex
OBJECT-TYPE
Firmware VPD index. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.1INTEGERread-onlydeprecated
mmBootROMVpdName
OBJECT-TYPE
Firmware VPD name description. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.2OCTET STRINGread-onlydeprecated
mmBootROMVpdBuildId
OBJECT-TYPE
Firmware VPD build identification. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.3OCTET STRINGread-onlydeprecated
mmBootROMVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.4OCTET STRINGread-onlydeprecated
mmBootROMVpdFilename
OBJECT-TYPE
Firmware VPD file name. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.5OCTET STRINGread-onlydeprecated
mmBootROMVpdBuildDate
OBJECT-TYPE
Firmware VPD build date. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.6OCTET STRINGread-onlydeprecated
mmRemoteControlVpdTable
OBJECT-TYPE
Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3not-accessibledeprecated
mmRemoteControlVpdEntry
OBJECT-TYPE
MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1not-accessibledeprecated
mmRemoteControlVpdIndex
OBJECT-TYPE
Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.1INTEGERread-onlydeprecated
mmRemoteControlVpdName
OBJECT-TYPE
Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.2OCTET STRINGread-onlydeprecated
mmRemoteControlVpdBuildId
OBJECT-TYPE
Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.3OCTET STRINGread-onlydeprecated
mmRemoteControlVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.4OCTET STRINGread-onlydeprecated
mmRemoteControlVpdFilename
OBJECT-TYPE
Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.5OCTET STRINGread-onlydeprecated
mmRemoteControlVpdBuildDate
OBJECT-TYPE
Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.6OCTET STRINGread-onlydeprecated
mmPS2toUSBConvVpdTable
OBJECT-TYPE
Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4not-accessibledeprecated
mmPS2toUSBConvVpdEntry
OBJECT-TYPE
MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1not-accessibledeprecated
mmPS2toUSBConvVpdIndex
OBJECT-TYPE
Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.1INTEGERread-onlydeprecated
mmPS2toUSBConvVpdName
OBJECT-TYPE
Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.2OCTET STRINGread-onlydeprecated
mmPS2toUSBConvVpdBuildId
OBJECT-TYPE
Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.3OCTET STRINGread-onlydeprecated
mmPS2toUSBConvVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.4OCTET STRINGread-onlydeprecated
mmPS2toUSBConvVpdFilename
OBJECT-TYPE
Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.5OCTET STRINGread-onlydeprecated
mmPS2toUSBConvVpdBuildDate
OBJECT-TYPE
Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.6OCTET STRINGread-onlydeprecated
mmToUSBIntfVpdTable
OBJECT-TYPE
Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5not-accessibledeprecated
mmToUSBIntfVpdEntry
OBJECT-TYPE
MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1not-accessibledeprecated
mmToUSBIntfVpdIndex
OBJECT-TYPE
Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.1INTEGERread-onlydeprecated
mmToUSBIntfVpdName
OBJECT-TYPE
Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.2OCTET STRINGread-onlydeprecated
mmToUSBIntfVpdBuildId
OBJECT-TYPE
Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.3OCTET STRINGread-onlydeprecated
mmToUSBIntfVpdRevisonNumber
OBJECT-TYPE
Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.4OCTET STRINGread-onlydeprecated
mmToUSBIntfVpdFilename
OBJECT-TYPE
Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.5OCTET STRINGread-onlydeprecated
mmToUSBIntfVpdBuildDate
OBJECT-TYPE
Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.6OCTET STRINGread-onlydeprecated
bladeHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.4
bladeHardwareVpdTable
OBJECT-TYPE
Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1not-accessiblemandatory
bladeHardwareVpdEntry
OBJECT-TYPE
Blade hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1not-accessiblemandatory
bladeHardwareVpdIndex
OBJECT-TYPE
Blade hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1INTEGERread-onlymandatory
bladeHardwareVpdBayNumber
OBJECT-TYPE
Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2OCTET STRINGread-onlymandatory
bladeHardwareVpdManufacturingId
OBJECT-TYPE
Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3OCTET STRINGread-onlymandatory
bladeHardwareVpdFruNumber
OBJECT-TYPE
Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4OCTET STRINGread-onlymandatory
bladeHardwareVpdHardwareRevision
OBJECT-TYPE
Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5INTEGERread-onlymandatory
bladeHardwareVpdSerialNumber
OBJECT-TYPE
Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6OCTET STRINGread-onlymandatory
bladeHardwareVpdMachineType
OBJECT-TYPE
Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7OCTET STRINGread-onlymandatory
bladeHardwareVpdUuid
OBJECT-TYPE
Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8OCTET STRINGread-onlymandatory
bladeHardwareVpdManufDate
OBJECT-TYPE
Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9OCTET STRINGread-onlymandatory
bladeHardwareVpdPartNumber
OBJECT-TYPE
Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10OCTET STRINGread-onlymandatory
bladeHardwareVpdFruSerial
OBJECT-TYPE
Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11OCTET STRINGread-onlymandatory
bladeHardwareVpdMachineModel
OBJECT-TYPE
Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12OCTET STRINGread-onlymandatory
bladeHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13OCTET STRINGread-onlymandatory
bladeHardwareVpdProductId
OBJECT-TYPE
Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14OCTET STRINGread-onlymandatory
bladeHardwareVpdSubManufacturerId
OBJECT-TYPE
Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15OCTET STRINGread-onlymandatory
bladeHardwareVpdClei
OBJECT-TYPE
Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16OCTET STRINGread-onlymandatory
bladeHardwareVpdHardwareRevisionString
OBJECT-TYPE
Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17OCTET STRINGread-onlymandatory
bladeDaughterVpdCardType
OBJECT-TYPE
Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20INTEGER {unknown(0), networkExpansion(1), storageExpansion(2), pciExpansion(3), genericExpansion(4)}read-onlymandatory
bladeDaughterVpdManufacturingId
OBJECT-TYPE
Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21OCTET STRINGread-onlymandatory
bladeDaughterVpdFruNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22OCTET STRINGread-onlymandatory
bladeDaughterVpdHardwareRevision
OBJECT-TYPE
Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23INTEGERread-onlymandatory
bladeDaughterVpdSerialNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24OCTET STRINGread-onlymandatory
bladeDaughterVpdMachineType
OBJECT-TYPE
Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25OCTET STRINGread-onlymandatory
bladeDaughterVpdUuid
OBJECT-TYPE
Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26OCTET STRINGread-onlymandatory
bladeDaughterVpdManufDate
OBJECT-TYPE
Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27OCTET STRINGread-onlymandatory
bladeDaughterVpdPartNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28OCTET STRINGread-onlymandatory
bladeDaughterVpdFruSerial
OBJECT-TYPE
Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29OCTET STRINGread-onlymandatory
bladeDaughterVpdManufacturingIDNumber
OBJECT-TYPE
Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30OCTET STRINGread-onlymandatory
bladeDaughterVpdProductId
OBJECT-TYPE
Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31OCTET STRINGread-onlymandatory
bladeDaughterVpdSubManufacturerId
OBJECT-TYPE
Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32OCTET STRINGread-onlymandatory
bladeDaughterVpdClei
OBJECT-TYPE
Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33OCTET STRINGread-onlymandatory
bladeDaughterVpdHardwareRevisionString
OBJECT-TYPE
Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34OCTET STRINGread-onlymandatory
bladeMACAddressVpdTable
OBJECT-TYPE
Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2not-accessiblemandatory
bladeMACAddressVpdEntry
OBJECT-TYPE
Blade MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1not-accessiblemandatory
bladeMACAddressVpdIndex
OBJECT-TYPE
Blade index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1INTEGERread-onlymandatory
bladeMACAddress1Vpd
OBJECT-TYPE
Blade MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2OCTET STRINGread-onlymandatory
bladeMACAddress2Vpd
OBJECT-TYPE
Blade MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3OCTET STRINGread-onlymandatory
bladeMACAddress3Vpd
OBJECT-TYPE
Blade MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4OCTET STRINGread-onlymandatory
bladeMACAddress4Vpd
OBJECT-TYPE
Blade MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5OCTET STRINGread-onlymandatory
bladeMACAddress5Vpd
OBJECT-TYPE
Blade MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6OCTET STRINGread-onlymandatory
bladeMACAddress6Vpd
OBJECT-TYPE
Blade MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7OCTET STRINGread-onlymandatory
bladeMACAddress7Vpd
OBJECT-TYPE
Blade MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8OCTET STRINGread-onlymandatory
bladeMACAddress8Vpd
OBJECT-TYPE
Blade MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16OCTET STRINGread-onlymandatory
bladeDaughterCard1MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24OCTET STRINGread-onlymandatory
bladeDaughterCard2MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32OCTET STRINGread-onlymandatory
bladeDaughterCard3MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40OCTET STRINGread-onlymandatory
bladeDaughterCard4MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress1Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress2Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress3Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress4Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress5Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress6Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress7Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48OCTET STRINGread-onlymandatory
bladeDaughterCard5MACAddress8Vpd
OBJECT-TYPE
Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress1Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress2Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress3Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress4Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress5Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress6Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress7Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress8Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress9Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 9. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.108OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress10Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 10. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.109OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress11Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 11. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.110OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress12Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 12. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.111OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress13Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 13. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.112OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress14Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 14. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.113OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress15Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 15. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.114OCTET STRINGread-onlymandatory
bladeHSDaughterCard1MACAddress16Vpd
OBJECT-TYPE
Blade high speed expansion card (daughter card) 1 MAC address 16. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.115OCTET STRINGread-onlymandatory
bladeSideCardMACAddress1Vpd
OBJECT-TYPE
Blade side card MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164OCTET STRINGread-onlymandatory
bladeSideCardMACAddress2Vpd
OBJECT-TYPE
Blade side card MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165OCTET STRINGread-onlymandatory
bladeSideCardMACAddress3Vpd
OBJECT-TYPE
Blade side card MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166OCTET STRINGread-onlymandatory
bladeSideCardMACAddress4Vpd
OBJECT-TYPE
Blade side card MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167OCTET STRINGread-onlymandatory
bladeSideCardMACAddress5Vpd
OBJECT-TYPE
Blade side card MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168OCTET STRINGread-onlymandatory
bladeSideCardMACAddress6Vpd
OBJECT-TYPE
Blade side card MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169OCTET STRINGread-onlymandatory
bladeSideCardMACAddress7Vpd
OBJECT-TYPE
Blade side card MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170OCTET STRINGread-onlymandatory
bladeSideCardMACAddress8Vpd
OBJECT-TYPE
Blade side card MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171OCTET STRINGread-onlymandatory
bladeExpBoardVpdTable
OBJECT-TYPE
Table of VPD information for the blade expansion board components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3not-accessiblemandatory
bladeExpBoardVpdEntry
OBJECT-TYPE
Blade expansion board VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1not-accessiblemandatory
bladeExpBoardVpdIndex
OBJECT-TYPE
Blade expansion board VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.1INTEGERread-onlymandatory
bladeExpBoardVpdBayNumber
OBJECT-TYPE
Blade expansion board VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.2OCTET STRINGread-onlymandatory
bladeExpBoardVpdManufacturingId
OBJECT-TYPE
Blade expansion board VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.3OCTET STRINGread-onlymandatory
bladeExpBoardVpdFruNumber
OBJECT-TYPE
Blade expansion board VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.4OCTET STRINGread-onlymandatory
bladeExpBoardVpdHardwareRevision
OBJECT-TYPE
Blade expansion board VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.5INTEGERread-onlymandatory
bladeExpBoardVpdSerialNumber
OBJECT-TYPE
Blade expansion board VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.6OCTET STRINGread-onlymandatory
bladeExpBoardVpdMachineType
OBJECT-TYPE
Blade expansion board VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.7OCTET STRINGread-onlymandatory
bladeExpBoardVpdUuid
OBJECT-TYPE
Blade expansion board VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.8OCTET STRINGread-onlymandatory
bladeExpBoardVpdManufDate
OBJECT-TYPE
Blade expansion board VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.9OCTET STRINGread-onlymandatory
bladeExpBoardVpdPartNumber
OBJECT-TYPE
Blade expansion board VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.10OCTET STRINGread-onlymandatory
bladeExpBoardVpdFruSerial
OBJECT-TYPE
Blade expansion board VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.11OCTET STRINGread-onlymandatory
bladeExpBoardVpdMachineModel
OBJECT-TYPE
Blade expansion board VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.12OCTET STRINGread-onlymandatory
bladeExpBoardVpdManufacturingIDNumber
OBJECT-TYPE
Blade expansion board VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.13OCTET STRINGread-onlymandatory
bladeExpBoardVpdProductId
OBJECT-TYPE
Blade expansion board VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.14OCTET STRINGread-onlymandatory
bladeExpBoardVpdSubManufacturerId
OBJECT-TYPE
Blade expansion board VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.15OCTET STRINGread-onlymandatory
bladeExpBoardVpdClei
OBJECT-TYPE
Blade expansion board VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.16OCTET STRINGread-onlymandatory
bladeExpBoardVpdBladeBayNumber
OBJECT-TYPE
Blade bay number of the blade expansion board. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.19OCTET STRINGread-onlymandatory
bladeExpBoardVpdCardType
OBJECT-TYPE
Blade expansion board VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.20INTEGER {unknown(0), storageExpansion(1), pciExpansion(2)}read-onlymandatory
bladeExpBoardVpdCardSubType
OBJECT-TYPE
Blade expansion board VPD subtype. Describes the expansion board type with more granularity. bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Generations), peu1 = PCI Expansion (1st Generation), peu2 = PCI Expansion Unit II, peu3 = bpe3 = PCI Express Expansion Unit, bie= Blade I/O Expansion For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.21INTEGER {unknown(0), bse1(1), bse2(2), bse3(3), peu1(11), peu2(12), peu3(13), bie(21)}read-onlymandatory
bladeExpBoardVpdHardwareRevisionString
OBJECT-TYPE
Blade expansion board VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.22OCTET STRINGread-onlymandatory
bladeSideCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade side card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4not-accessiblemandatory
bladeSideCardVpdEntry
OBJECT-TYPE
Blade side card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1not-accessiblemandatory
bladeSideCardVpdIndex
OBJECT-TYPE
Blade side card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.1INTEGERread-onlymandatory
bladeSideCardVpdBayNumber
OBJECT-TYPE
Blade side card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.2OCTET STRINGread-onlymandatory
bladeSideCardVpdManufacturingId
OBJECT-TYPE
Blade side card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.3OCTET STRINGread-onlymandatory
bladeSideCardVpdFruNumber
OBJECT-TYPE
Blade side card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.4OCTET STRINGread-onlymandatory
bladeSideCardVpdHardwareRevision
OBJECT-TYPE
Blade side card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.5INTEGERread-onlymandatory
bladeSideCardVpdSerialNumber
OBJECT-TYPE
Blade side card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.6OCTET STRINGread-onlymandatory
bladeSideCardVpdMachineType
OBJECT-TYPE
Blade side card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.7OCTET STRINGread-onlymandatory
bladeSideCardVpdUuid
OBJECT-TYPE
Blade side card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.8OCTET STRINGread-onlymandatory
bladeSideCardVpdManufDate
OBJECT-TYPE
Blade side card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.9OCTET STRINGread-onlymandatory
bladeSideCardVpdPartNumber
OBJECT-TYPE
Blade side card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.10OCTET STRINGread-onlymandatory
bladeSideCardVpdFruSerial
OBJECT-TYPE
Blade side card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.11OCTET STRINGread-onlymandatory
bladeSideCardVpdMachineModel
OBJECT-TYPE
Blade side card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.12OCTET STRINGread-onlymandatory
bladeSideCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade side card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.13OCTET STRINGread-onlymandatory
bladeSideCardVpdProductId
OBJECT-TYPE
Blade side card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.14OCTET STRINGread-onlymandatory
bladeSideCardVpdSubManufacturerId
OBJECT-TYPE
Blade side card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.15OCTET STRINGread-onlymandatory
bladeSideCardVpdClei
OBJECT-TYPE
Blade side card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.16OCTET STRINGread-onlymandatory
bladeSideCardVpdBladeBayNumber
OBJECT-TYPE
Blade bay number of the blade side card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.19OCTET STRINGread-onlymandatory
bladeSideCardVpdHardwareRevisionString
OBJECT-TYPE
Blade side card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.20OCTET STRINGread-onlymandatory
bladeExpCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5not-accessiblemandatory
bladeExpCardVpdEntry
OBJECT-TYPE
Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1not-accessiblemandatory
bladeExpCardVpdIndex
OBJECT-TYPE
Blade expansion card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1INTEGERread-onlymandatory
bladeExpCardVpdBayNumber
OBJECT-TYPE
Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2OCTET STRINGread-onlymandatory
bladeExpCardVpdManufacturingId
OBJECT-TYPE
Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3OCTET STRINGread-onlymandatory
bladeExpCardVpdFruNumber
OBJECT-TYPE
Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4OCTET STRINGread-onlymandatory
bladeExpCardVpdHardwareRevision
OBJECT-TYPE
Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5INTEGERread-onlymandatory
bladeExpCardVpdSerialNumber
OBJECT-TYPE
Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6OCTET STRINGread-onlymandatory
bladeExpCardVpdMachineType
OBJECT-TYPE
Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7OCTET STRINGread-onlymandatory
bladeExpCardVpdUuid
OBJECT-TYPE
Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8OCTET STRINGread-onlymandatory
bladeExpCardVpdManufDate
OBJECT-TYPE
Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9OCTET STRINGread-onlymandatory
bladeExpCardVpdPartNumber
OBJECT-TYPE
Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10OCTET STRINGread-onlymandatory
bladeExpCardVpdFruSerial
OBJECT-TYPE
Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11OCTET STRINGread-onlymandatory
bladeExpCardVpdMachineModel
OBJECT-TYPE
Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12OCTET STRINGread-onlymandatory
bladeExpCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13OCTET STRINGread-onlymandatory
bladeExpCardVpdProductId
OBJECT-TYPE
Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14OCTET STRINGread-onlymandatory
bladeExpCardVpdSubManufacturerId
OBJECT-TYPE
Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15OCTET STRINGread-onlymandatory
bladeExpCardVpdClei
OBJECT-TYPE
Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16OCTET STRINGread-onlymandatory
bladeExpCardVpdBladeBayNumber
OBJECT-TYPE
Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19OCTET STRINGread-onlymandatory
bladeExpCardVpdCardTypeInfo
OBJECT-TYPE
Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21INTEGER {unknown(0), bladeEthernetExpCard(1), bladeFiberChannelExpCard(2), serialPortExpCard(3), bladeOpticalPassThrough(4), bladeInfinibandExpCard(5), bladeIscsiExpCard(6), bladeGenericExpCard(7), bladeNetworkCFFeExpCard(8), bladeSASConnectivityCard(9), bladeSATAConnectivityCard(10), bladeNetworkCFFzExpCard(11), bladeNetworkCNAExpCard(12), bladeSSDExpCard(13), bladePCIExp(14), bladeGraphicsExp(15), bladeIOExp(16), bladeMemoryExp(17), bladeProcessorExp(18), bladeGenericExp(19)}read-onlymandatory
bladeExpCardVpdHighSpeed
OBJECT-TYPE
Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22INTEGER {no(0), yes(1), notApplicable(255)}read-onlymandatory
bladeExpCardVpdHardwareRevisionString
OBJECT-TYPE
Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23OCTET STRINGread-onlymandatory
bladecKVMCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade concurrent keyboard, video, and mouse (cKVM) card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6not-accessiblemandatory
bladecKVMCardVpdEntry
OBJECT-TYPE
Blade concurrent keyboard, video, and mouse (cKVM) card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1not-accessiblemandatory
bladecKVMCardVpdIndex
OBJECT-TYPE
Blade concurrent keyboard mouse video (cKVM) card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.1INTEGERread-onlymandatory
bladecKVMCardVpdBayNumber
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.2OCTET STRINGread-onlymandatory
bladecKVMCardVpdManufacturingId
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.3OCTET STRINGread-onlymandatory
bladecKVMCardVpdFruNumber
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.4OCTET STRINGread-onlymandatory
bladecKVMCardVpdHardwareRevision
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.5INTEGERread-onlymandatory
bladecKVMCardVpdSerialNumber
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.6OCTET STRINGread-onlymandatory
bladecKVMCardVpdMachineType
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.7OCTET STRINGread-onlymandatory
bladecKVMCardVpdUuid
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.8OCTET STRINGread-onlymandatory
bladecKVMCardVpdManufDate
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.9OCTET STRINGread-onlymandatory
bladecKVMCardVpdPartNumber
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.10OCTET STRINGread-onlymandatory
bladecKVMCardVpdFruSerial
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.11OCTET STRINGread-onlymandatory
bladecKVMCardVpdMachineModel
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.12OCTET STRINGread-onlymandatory
bladecKVMCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.13OCTET STRINGread-onlymandatory
bladecKVMCardVpdProductId
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.14OCTET STRINGread-onlymandatory
bladecKVMCardVpdSubManufacturerId
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.15OCTET STRINGread-onlymandatory
bladecKVMCardVpdClei
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.16OCTET STRINGread-onlymandatory
bladecKVMCardVpdHardwareRevisionString
OBJECT-TYPE
Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.17OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpdTable
OBJECT-TYPE
Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7not-accessiblemandatory
bladeAndExpCardWwnGuidVpdEntry
OBJECT-TYPE
Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1not-accessiblemandatory
bladeAndExpCardWwnGuidVpdIndex
OBJECT-TYPE
Blade or expansion card index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1INTEGERread-onlymandatory
bladeAndExpCardWwnGuidVpdBayNumber
OBJECT-TYPE
Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpdName
OBJECT-TYPE
The name of the blade or expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpdBladeBayNumber
OBJECT-TYPE
For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpdType
OBJECT-TYPE
Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5INTEGER {notAvailable(0), wwn(1), guid(2), sas(3)}read-onlymandatory
bladeAndExpCardWwnGuidVpd1
OBJECT-TYPE
Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd2
OBJECT-TYPE
Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd3
OBJECT-TYPE
Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd4
OBJECT-TYPE
Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd5
OBJECT-TYPE
Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd6
OBJECT-TYPE
Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd7
OBJECT-TYPE
Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12OCTET STRINGread-onlymandatory
bladeAndExpCardWwnGuidVpd8
OBJECT-TYPE
Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13OCTET STRINGread-onlymandatory
bladeManagementCardVpdTable
OBJECT-TYPE
Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8not-accessiblemandatory
bladeManagementCardVpdEntry
OBJECT-TYPE
Blade management card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1not-accessiblemandatory
bladeManagementCardVpdIndex
OBJECT-TYPE
Blade management card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1INTEGERread-onlymandatory
bladeManagementCardVpdBayNumber
OBJECT-TYPE
Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2OCTET STRINGread-onlymandatory
bladeManagementCardVpdManufacturingId
OBJECT-TYPE
Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3OCTET STRINGread-onlymandatory
bladeManagementCardVpdFruNumber
OBJECT-TYPE
Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4OCTET STRINGread-onlymandatory
bladeManagementCardVpdHardwareRevision
OBJECT-TYPE
Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5INTEGERread-onlymandatory
bladeManagementCardVpdSerialNumber
OBJECT-TYPE
Blade management card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6OCTET STRINGread-onlymandatory
bladeManagementCardVpdMachineType
OBJECT-TYPE
Blade management card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7OCTET STRINGread-onlymandatory
bladeManagementCardVpdUuid
OBJECT-TYPE
Blade management card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8OCTET STRINGread-onlymandatory
bladeManagementCardVpdManufDate
OBJECT-TYPE
Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9OCTET STRINGread-onlymandatory
bladeManagementCardVpdPartNumber
OBJECT-TYPE
Blade management card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10OCTET STRINGread-onlymandatory
bladeManagementCardVpdFruSerial
OBJECT-TYPE
Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11OCTET STRINGread-onlymandatory
bladeManagementCardVpdMachineModel
OBJECT-TYPE
Blade management card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12OCTET STRINGread-onlymandatory
bladeManagementCardVpdManufacturingIDNumber
OBJECT-TYPE
Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13OCTET STRINGread-onlymandatory
bladeManagementCardVpdProductId
OBJECT-TYPE
Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14OCTET STRINGread-onlymandatory
bladeManagementCardVpdSubManufacturerId
OBJECT-TYPE
Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15OCTET STRINGread-onlymandatory
bladeManagementCardVpdClei
OBJECT-TYPE
Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16OCTET STRINGread-onlymandatory
bladeManagementCardVpdHardwareRevisionString
OBJECT-TYPE
Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17OCTET STRINGread-onlymandatory
bladeFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.5
bladeBiosVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.1not-accessiblemandatory
bladeBiosVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1not-accessiblemandatory
bladeBiosVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1INTEGERread-onlymandatory
bladeBiosVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeBiosVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladeBiosVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bladeBiosVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5OCTET STRINGread-onlymandatory
bladeBiosVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6OCTET STRINGread-onlymandatory
bladeBiosVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7OCTET STRINGread-onlymandatory
bladeBiosVpdDate
OBJECT-TYPE
The date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8OCTET STRINGread-onlymandatory
bladeBiosVpdLevelStatus
OBJECT-TYPE
The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9OCTET STRINGread-onlymandatory
bladeDiagsVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.2not-accessiblemandatory
bladeDiagsVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1not-accessiblemandatory
bladeDiagsVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1INTEGERread-onlymandatory
bladeDiagsVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeDiagsVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladeDiagsVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bladeDiagsVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5OCTET STRINGread-onlymandatory
bladeDiagsVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6OCTET STRINGread-onlymandatory
bladeDiagsVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7OCTET STRINGread-onlymandatory
bladeDiagsVpdDate
OBJECT-TYPE
The date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8OCTET STRINGread-onlymandatory
bladeDiagsVpdLevelStatus
OBJECT-TYPE
The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9OCTET STRINGread-onlymandatory
bladeSysMgmtProcVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.3not-accessiblemandatory
bladeSysMgmtProcVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1not-accessiblemandatory
bladeSysMgmtProcVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1INTEGERread-onlymandatory
bladeSysMgmtProcVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeSysMgmtProcVpdExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladeSysMgmtProcVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bladeSysMgmtProcVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5OCTET STRINGread-onlymandatory
bladeSysMgmtProcVpdBuildId
OBJECT-TYPE
The build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6OCTET STRINGread-onlymandatory
bladeSysMgmtProcVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7OCTET STRINGread-onlymandatory
bladeSysMgmtProcVpdLevelStatus
OBJECT-TYPE
The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8OCTET STRINGread-onlymandatory
bladecKVMVPDTable
OBJECT-TYPE
Table of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.4not-accessiblemandatory
bladecKVMVPDEntry
OBJECT-TYPE
Blade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1not-accessiblemandatory
bladecKVMVpdIndex
OBJECT-TYPE
Blade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.1INTEGERread-onlymandatory
bladecKVMVpdId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladecKVMVpdExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladecKVMVpdPowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bladecKVMVpdName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.5OCTET STRINGread-onlymandatory
bladecKVMVpdRevision
OBJECT-TYPE
The revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.7OCTET STRINGread-onlymandatory
bladeFWBuildIDs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.5.5
bladeFWBuildIDTable
OBJECT-TYPE
Table of Blade Firmware Build ID entries information.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1not-accessiblemandatory
bladeFWBuildIDEntry
OBJECT-TYPE
Blade Firmware Build ID table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1not-accessiblemandatory
bladeFWBuildIDIndex
OBJECT-TYPE
The index number of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.1INTEGERread-onlymandatory
bladeFWBuildMfg
OBJECT-TYPE
The Manufacturer property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.2OCTET STRINGread-writemandatory
bladeFWBuildMT
OBJECT-TYPE
The Machine Type property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.3OCTET STRINGread-writemandatory
bladeFWBuildFWType
OBJECT-TYPE
The Firmware Type property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.4OCTET STRINGread-writemandatory
bladeFWBuildID
OBJECT-TYPE
The Build ID property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.5OCTET STRINGread-writemandatory
bladeFWBuildRev
OBJECT-TYPE
The Build Revision property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.6OCTET STRINGread-writemandatory
createBladeFWBuildIDs
OBJECT-TYPE
Create one new Build ID List from current installed blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.2INTEGER {execute(1)}write-onlymandatory
addBladeFWBuildID
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3
addBladeMfg
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to set Manufacturer property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.1OCTET STRINGread-writemandatory
addBladeMt
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to set Machine Type property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.2OCTET STRINGread-writemandatory
addBladeFt
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to set Firmware Type property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.3OCTET STRINGread-writemandatory
addBladeBuildID
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to set Build ID property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.4OCTET STRINGread-writemandatory
addBladeBuildRev
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to set Build Revision property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.5OCTET STRINGread-writemandatory
exeBladeAdding
OBJECT-TYPE
Add one Build ID entry into the Build ID List. This is to perform the adding action. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.6INTEGER {execute(1)}write-onlymandatory
rmBladeFWBuildID
OBJECT-TYPE
Remove one Build ID entry from the Build ID List. The index of the Build ID entry in the list is required. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.4INTEGERwrite-onlymandatory
rmAllBladeFWBuildIDs
OBJECT-TYPE
Remove all Build ID entries from the Build ID List. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.5INTEGER {execute(1)}write-onlymandatory
buildIDFileName
OBJECT-TYPE
File name of the Build ID list that will be used in import function.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.6OCTET STRING (SIZE(0..254))read-writemandatory
buildIDURIName
OBJECT-TYPE
Contains the fully qualified remote location of the build ID list. Use buildIDFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the build ID list resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the build ID list is /tmp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.7OCTET STRING (SIZE(0..254))read-writemandatory
buildIDtftpIP
OBJECT-TYPE
If importing/exporting via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2).
1.3.6.1.4.1.2.3.51.2.2.21.5.5.8OCTET STRING (SIZE(0..63))read-writemandatory
importBladeFWBuildIDs
OBJECT-TYPE
Import one Build ID List set by the buildIDFilename from a specific location set by buildIDServer.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.9INTEGER {execute(1)}write-onlymandatory
exportBladeFWBuildIDs
OBJECT-TYPE
Export the current Build ID List from the active AMM to a specific location set by buildIDServer. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.10INTEGER {execute(1)}write-onlymandatory
statusBladeFWBuildIDs
OBJECT-TYPE
Gives the status message from the last import or export operation.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.11OCTET STRINGread-onlymandatory
smHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.6
smHardwareVpdTable
OBJECT-TYPE
Table of the switch module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1not-accessiblemandatory
smHardwareVpdEntry
OBJECT-TYPE
Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1not-accessiblemandatory
smHardwareVpdIndex
OBJECT-TYPE
Switch module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1INTEGERread-onlymandatory
smHardwareVpdBayNumber
OBJECT-TYPE
Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2OCTET STRINGread-onlymandatory
smHardwareVpdManufacturingId
OBJECT-TYPE
Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3OCTET STRINGread-onlymandatory
smHardwareVpdFruNumber
OBJECT-TYPE
Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4OCTET STRINGread-onlymandatory
smHardwareVpdHardwareRevision
OBJECT-TYPE
Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5INTEGERread-onlymandatory
smHardwareVpdUuid
OBJECT-TYPE
Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8OCTET STRINGread-onlymandatory
smHardwareVpdManufDate
OBJECT-TYPE
Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9OCTET STRINGread-onlymandatory
smHardwareVpdPartNumber
OBJECT-TYPE
Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10OCTET STRINGread-onlymandatory
smHardwareVpdFruSerial
OBJECT-TYPE
Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11OCTET STRINGread-onlymandatory
smHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12OCTET STRINGread-onlymandatory
smHardwareVpdProductId
OBJECT-TYPE
Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13OCTET STRINGread-onlymandatory
smHardwareVpdSubManufacturerId
OBJECT-TYPE
Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14OCTET STRINGread-onlymandatory
smHardwareVpdClei
OBJECT-TYPE
Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15OCTET STRINGread-onlymandatory
smHardwareVpdWwnGuid
OBJECT-TYPE
Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16OCTET STRINGread-onlymandatory
smHardwareVpdWwnGuidType
OBJECT-TYPE
The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17OCTET STRINGread-onlymandatory
smHardwareVpdWidth
OBJECT-TYPE
The width of the switch module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18INTEGERread-onlymandatory
smHardwareVpdHardwareRevisionString
OBJECT-TYPE
Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20OCTET STRINGread-onlymandatory
smInpHardwareVpdTable
OBJECT-TYPE
Table of the switch interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2not-accessiblemandatory
smInpHardwareVpdEntry
OBJECT-TYPE
Switch Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1not-accessiblemandatory
smInpHardwareVpdIndex
OBJECT-TYPE
Switch Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.1INTEGERread-onlymandatory
smInpHardwareVpdBayNumber
OBJECT-TYPE
Switch Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.2OCTET STRINGread-onlymandatory
smInpHardwareVpdManufacturingId
OBJECT-TYPE
Switch Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.3OCTET STRINGread-onlymandatory
smInpHardwareVpdFruNumber
OBJECT-TYPE
Switch Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.4OCTET STRINGread-onlymandatory
smInpHardwareVpdHardwareRevision
OBJECT-TYPE
Switch Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.5INTEGERread-onlymandatory
smInpHardwareVpdUuid
OBJECT-TYPE
Switch Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.8OCTET STRINGread-onlymandatory
smInpHardwareVpdManufDate
OBJECT-TYPE
Switch Interposer hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.9OCTET STRINGread-onlymandatory
smInpHardwareVpdPartNumber
OBJECT-TYPE
Switch Interposer hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.10OCTET STRINGread-onlymandatory
smInpHardwareVpdFruSerial
OBJECT-TYPE
Switch Interposer module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.11OCTET STRINGread-onlymandatory
smInpHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Switch Interposer module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.12OCTET STRINGread-onlymandatory
smInpHardwareVpdProductId
OBJECT-TYPE
Switch Interposer module hardware VPD product ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.13OCTET STRINGread-onlymandatory
smInpHardwareVpdSubManufacturerId
OBJECT-TYPE
Switch Interposer module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.14OCTET STRINGread-onlymandatory
smInpHardwareVpdClei
OBJECT-TYPE
Switch Interposer module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.15OCTET STRINGread-onlymandatory
smInpHardwareVpdWwnGuid
OBJECT-TYPE
Switch Interposer module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.16OCTET STRINGread-onlymandatory
smInpHardwareVpdWwnGuidType
OBJECT-TYPE
The Switch Interposer WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.17OCTET STRINGread-onlymandatory
smInpHardwareVpdWidth
OBJECT-TYPE
The width of the switch Interposer module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.18INTEGERread-onlymandatory
smInpHardwareVpdName
OBJECT-TYPE
The Switch Interposer Name. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.19OCTET STRINGread-onlymandatory
smInpHardwareVpdHardwareRevisionString
OBJECT-TYPE
Switch Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.20OCTET STRINGread-onlymandatory
smFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.7
smMainAppVpdTable
OBJECT-TYPE
Switch module main application VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.1not-accessiblemandatory
smMainAppVpdEntry
OBJECT-TYPE
Switch module main application VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1not-accessiblemandatory
smMainAppVpdIndex
OBJECT-TYPE
Switch module main application VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1INTEGERread-onlymandatory
smMainAppVpdId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smMainAppVpdExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smMainAppVpdSwitchType
OBJECT-TYPE
Indicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)}read-onlymandatory
smMainApp1VpdBuildId
OBJECT-TYPE
Switch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5OCTET STRINGread-onlymandatory
smMainApp1VpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6OCTET STRINGread-onlymandatory
smMainApp1VpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7OCTET STRINGread-onlymandatory
smMainApp2VpdBuildId
OBJECT-TYPE
Switch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8OCTET STRINGread-onlymandatory
smMainApp2VpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9OCTET STRINGread-onlymandatory
smMainApp2VpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10OCTET STRINGread-onlymandatory
smMainApp3VpdBuildId
OBJECT-TYPE
I/O Module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11OCTET STRINGread-onlymandatory
smMainApp3VpdBuildDate
OBJECT-TYPE
I/O Module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12OCTET STRINGread-onlymandatory
smMainApp3VpdRevisionNumber
OBJECT-TYPE
I/O Module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13OCTET STRINGread-onlymandatory
smMainAppVpdSwitchSubType
OBJECT-TYPE
Indicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)}read-onlymandatory
smBootRomVpdTable
OBJECT-TYPE
Switch module boot ROM VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.2not-accessiblemandatory
smBootRomVpdEntry
OBJECT-TYPE
Switch module boot ROM VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1not-accessiblemandatory
smBootRomVpdIndex
OBJECT-TYPE
Switch module boot ROM VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1INTEGERread-onlymandatory
smBootRomVpdId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smBootRomVpdExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3INTEGER {false(0), true(1)}read-onlymandatory
smBootRomVpdSwitchType
OBJECT-TYPE
Indicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)}read-onlymandatory
smBootRomVpdBuildId
OBJECT-TYPE
Switch module firmware build ID.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5OCTET STRINGread-onlymandatory
smBootRomVpdBuildDate
OBJECT-TYPE
Switch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6OCTET STRINGread-onlymandatory
smBootRomVpdRevisionNumber
OBJECT-TYPE
Switch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7OCTET STRINGread-onlymandatory
smBootRomVpdSwitchSubType
OBJECT-TYPE
Indicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)}read-onlymandatory
pmHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.8
pmHardwareVpdTable
OBJECT-TYPE
Table of the power module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1not-accessiblemandatory
pmHardwareVpdEntry
OBJECT-TYPE
Power module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1not-accessiblemandatory
pmHardwareVpdIndex
OBJECT-TYPE
Power module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1INTEGERread-onlymandatory
pmHardwareVpdBayNumber
OBJECT-TYPE
Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2OCTET STRINGread-onlymandatory
pmHardwareVpdManufacturingId
OBJECT-TYPE
Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3OCTET STRINGread-onlymandatory
pmHardwareVpdFruNumber
OBJECT-TYPE
Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4OCTET STRINGread-onlymandatory
pmHardwareVpdHardwareRevision
OBJECT-TYPE
Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5INTEGERread-onlymandatory
pmHardwareVpdUuid
OBJECT-TYPE
Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8OCTET STRINGread-onlymandatory
pmHardwareVpdManufDate
OBJECT-TYPE
Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9OCTET STRINGread-onlymandatory
pmHardwareVpdPartNumber
OBJECT-TYPE
Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10OCTET STRINGread-onlymandatory
pmHardwareVpdFruSerial
OBJECT-TYPE
Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11OCTET STRINGread-onlymandatory
pmHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12OCTET STRINGread-onlymandatory
pmHardwareVpdProductId
OBJECT-TYPE
Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13OCTET STRINGread-onlymandatory
pmHardwareVpdSubManufacturerId
OBJECT-TYPE
Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14OCTET STRINGread-onlymandatory
pmHardwareVpdClei
OBJECT-TYPE
Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15OCTET STRINGread-onlymandatory
pmHardwareVpdHardwareRevisionString
OBJECT-TYPE
Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16OCTET STRINGread-onlymandatory
mtHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.9
mtHardwareVpdManufacturingId
OBJECT-TYPE
Media tray 1 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.3OCTET STRINGread-onlymandatory
mtHardwareVpdFruNumber
OBJECT-TYPE
Media tray 1 hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.4OCTET STRINGread-onlymandatory
mtHardwareVpdHardwareRevision
OBJECT-TYPE
Media tray 1 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.9.5INTEGERread-onlymandatory
mtHardwareVpdUuid
OBJECT-TYPE
Media tray 1 hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.8OCTET STRINGread-onlymandatory
mtHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Media tray 1 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.9OCTET STRINGread-onlymandatory
mtHardwareVpdProductId
OBJECT-TYPE
Media tray 1 hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.10OCTET STRINGread-onlymandatory
mtHardwareVpdSubManufacturerId
OBJECT-TYPE
Media tray 1 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.11OCTET STRINGread-onlymandatory
mtHardwareVpdClei
OBJECT-TYPE
Media tray 1 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.12OCTET STRINGread-onlymandatory
mtHardwareVpdCF1Capacity
OBJECT-TYPE
Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.13OCTET STRINGread-onlymandatory
mtHardwareVpdCF2Capacity
OBJECT-TYPE
Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.14OCTET STRINGread-onlymandatory
mtHardwareVpdBBU1
OBJECT-TYPE
Indicates the presence of Battery Backup Unit 1. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.9.15INTEGER {no(0), yes(1)}read-onlymandatory
mtHardwareVpdBBU2
OBJECT-TYPE
Indicates the presence of Battery Backup Unit 2. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.9.16INTEGER {no(0), yes(1)}read-onlymandatory
mtHardwareVpdHardwareRevisionString
OBJECT-TYPE
Media tray 1 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.9.17OCTET STRINGread-onlymandatory
mtHardwareVpdManufDate
OBJECT-TYPE
Media tray 1 hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.9.18OCTET STRINGread-onlymandatory
mtHardwareVpdPartNumber
OBJECT-TYPE
Media tray 1 hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.9.19OCTET STRINGread-onlymandatory
mtHardwareVpdFruSerial
OBJECT-TYPE
Media tray 1 hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.9.20OCTET STRINGread-onlymandatory
mt2HardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.10
mt2HardwareVpdManufacturingId
OBJECT-TYPE
Media tray 2 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.3OCTET STRINGread-onlymandatory
mt2HardwareVpdFruNumber
OBJECT-TYPE
Media tray 2 hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.4OCTET STRINGread-onlymandatory
mt2HardwareVpdHardwareRevision
OBJECT-TYPE
Media tray 2 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.10.5INTEGERread-onlymandatory
mt2HardwareVpdUuid
OBJECT-TYPE
Media tray 2 hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.8OCTET STRINGread-onlymandatory
mt2HardwareVpdManufacturingIDNumber
OBJECT-TYPE
Media tray 2 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.9OCTET STRINGread-onlymandatory
mt2HardwareVpdProductId
OBJECT-TYPE
Media tray 2 hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.10OCTET STRINGread-onlymandatory
mt2HardwareVpdSubManufacturerId
OBJECT-TYPE
Media tray 2 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.11OCTET STRINGread-onlymandatory
mt2HardwareVpdClei
OBJECT-TYPE
Media tray 2 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.12OCTET STRINGread-onlymandatory
mt2HardwareVpdCF1Capacity
OBJECT-TYPE
Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.13OCTET STRINGread-onlymandatory
mt2HardwareVpdCF2Capacity
OBJECT-TYPE
Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.14OCTET STRINGread-onlymandatory
mt2HardwareVpdHardwareRevisionString
OBJECT-TYPE
Media tray 2 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.10.17OCTET STRINGread-onlymandatory
mt2HardwareVpdManufDate
OBJECT-TYPE
Media tray 2 hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.10.18OCTET STRINGread-onlymandatory
mt2HardwareVpdPartNumber
OBJECT-TYPE
Media tray 2 hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.10.19OCTET STRINGread-onlymandatory
mt2HardwareVpdFruSerial
OBJECT-TYPE
Media tray 2 hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.10.20OCTET STRINGread-onlymandatory
blowerFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.12
blowerControllerVPDTable
OBJECT-TYPE
Table of blower controller firmware vital product data (VPD) information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.21.12.1not-accessiblemandatory
blowerControllerVPDEntry
OBJECT-TYPE
Blower controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1not-accessiblemandatory
blowerControllerVpdIndex
OBJECT-TYPE
Blower controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1INTEGERread-onlymandatory
blowerControllerVpdId
OBJECT-TYPE
The numeric blower ID.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2INTEGER {blower1(1), blower2(2), blower3(3), blower4(4)}read-onlymandatory
blowerControllerVpdExists
OBJECT-TYPE
Indicates whether the blower specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
blowerControllerVpdRevision
OBJECT-TYPE
The revision of the blower controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7OCTET STRINGread-onlymandatory
blowerHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.13
blowerHardwareVpdTable
OBJECT-TYPE
Table of the blower hardware components. For consistent results, view as a table and not as individual entries. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.21.13.1not-accessiblemandatory
blowerHardwareVpdEntry
OBJECT-TYPE
Blower hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1not-accessiblemandatory
blowerHardwareVpdIndex
OBJECT-TYPE
Blower hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1INTEGERread-onlymandatory
blowerHardwareVpdBayNumber
OBJECT-TYPE
Blower hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2OCTET STRINGread-onlymandatory
blowerHardwareVpdManufacturingId
OBJECT-TYPE
Blower hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3OCTET STRINGread-onlymandatory
blowerHardwareVpdFruNumber
OBJECT-TYPE
Blower hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4OCTET STRINGread-onlymandatory
blowerHardwareVpdHardwareRevision
OBJECT-TYPE
Blower hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5INTEGERread-onlymandatory
blowerHardwareVpdUuid
OBJECT-TYPE
Blower hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8OCTET STRINGread-onlymandatory
blowerHardwareVpdManufDate
OBJECT-TYPE
Blower hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9OCTET STRINGread-onlymandatory
blowerHardwareVpdPartNumber
OBJECT-TYPE
Blower hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10OCTET STRINGread-onlymandatory
blowerHardwareVpdFruSerial
OBJECT-TYPE
Blower hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11OCTET STRINGread-onlymandatory
blowerHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Blower hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12OCTET STRINGread-onlymandatory
blowerHardwareVpdProductId
OBJECT-TYPE
Blower hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13OCTET STRINGread-onlymandatory
blowerHardwareVpdSubManufacturerId
OBJECT-TYPE
Blower hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14OCTET STRINGread-onlymandatory
blowerHardwareVpdClei
OBJECT-TYPE
Blower hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15OCTET STRINGread-onlymandatory
blowerHardwareVpdHardwareRevisionString
OBJECT-TYPE
Blower hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16OCTET STRINGread-onlymandatory
fanPackFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.14
fanPackControllerVPDTable
OBJECT-TYPE
Table of fan pack controller firmware vital product data (VPD) information. NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.21.14.1not-accessiblemandatory
fanPackControllerVPDEntry
OBJECT-TYPE
Fan Pack controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1not-accessiblemandatory
fanPackControllerVpdIndex
OBJECT-TYPE
Fan Pack controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1INTEGERread-onlymandatory
fanPackControllerVpdId
OBJECT-TYPE
The numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2INTEGER {fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4)}read-onlymandatory
fanPackControllerVpdExists
OBJECT-TYPE
Indicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
fanPackControllerVpdRevision
OBJECT-TYPE
The revision of the fan pack controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7OCTET STRINGread-onlymandatory
tapHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.15
tapHardwareVpdManufacturingId
OBJECT-TYPE
Telco Alarm Panel hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.3OCTET STRINGread-onlymandatory
tapHardwareVpdFruNumber
OBJECT-TYPE
Telco Alarm Panel hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.4OCTET STRINGread-onlymandatory
tapHardwareVpdHardwareRevision
OBJECT-TYPE
Telco Alarm Panel hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.15.5INTEGERread-onlymandatory
tapHardwareVpdUuid
OBJECT-TYPE
Telco Alarm Panel hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.8OCTET STRINGread-onlymandatory
tapHardwareVpdManufDate
OBJECT-TYPE
Telco Alarm Panel hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.9OCTET STRINGread-onlymandatory
tapHardwareVpdPartNumber
OBJECT-TYPE
Telco Alarm Panel hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.10OCTET STRINGread-onlymandatory
tapHardwareVpdFruSerial
OBJECT-TYPE
Telco Alarm Panel hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.11OCTET STRINGread-onlymandatory
tapHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Telco Alarm Panel hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.12OCTET STRINGread-onlymandatory
tapHardwareVpdProductId
OBJECT-TYPE
Telco Alarm Panel hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.13OCTET STRINGread-onlymandatory
tapHardwareVpdSubManufacturerId
OBJECT-TYPE
Telco Alarm Panel hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.14OCTET STRINGread-onlymandatory
tapHardwareVpdClei
OBJECT-TYPE
Telco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.15OCTET STRINGread-onlymandatory
tapHardwareVpdHardwareRevisionString
OBJECT-TYPE
Telco Alarm Panel hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.15.16OCTET STRINGread-onlymandatory
ncHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.16
ncHardwareVpdTable
OBJECT-TYPE
Table of the Network Clock hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1not-accessibledeprecated
ncHardwareVpdEntry
OBJECT-TYPE
Network Clock hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1not-accessibledeprecated
ncHardwareVpdIndex
OBJECT-TYPE
Network Clock hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.1INTEGERread-onlydeprecated
ncHardwareVpdBayNumber
OBJECT-TYPE
Network Clock hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.2OCTET STRINGread-onlydeprecated
ncHardwareVpdManufacturingId
OBJECT-TYPE
Network Clock hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.3OCTET STRINGread-onlydeprecated
ncHardwareVpdFruNumber
OBJECT-TYPE
Network Clock hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.4OCTET STRINGread-onlydeprecated
ncHardwareVpdHardwareRevision
OBJECT-TYPE
Network Clock hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.5INTEGERread-onlydeprecated
ncHardwareVpdUuid
OBJECT-TYPE
Network Clock hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.8OCTET STRINGread-onlydeprecated
ncHardwareVpdManufDate
OBJECT-TYPE
Network Clock hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.9OCTET STRINGread-onlydeprecated
ncHardwareVpdPartNumber
OBJECT-TYPE
Network Clock hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.10OCTET STRINGread-onlydeprecated
ncHardwareVpdFruSerial
OBJECT-TYPE
Network Clock hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.11OCTET STRINGread-onlydeprecated
ncHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Network Clock hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.12OCTET STRINGread-onlydeprecated
ncHardwareVpdProductId
OBJECT-TYPE
Network Clock hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.13OCTET STRINGread-onlydeprecated
ncHardwareVpdSubManufacturerId
OBJECT-TYPE
Network Clock hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.14OCTET STRINGread-onlydeprecated
ncHardwareVpdClei
OBJECT-TYPE
Network Clock hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.15OCTET STRINGread-onlydeprecated
ncHardwareVpdHardwareRevisionString
OBJECT-TYPE
Network Clock hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.16OCTET STRINGread-onlydeprecated
mxHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.17
mxHardwareVpdTable
OBJECT-TYPE
Table of the Multiplexer Expansion Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1not-accessiblemandatory
mxHardwareVpdEntry
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1not-accessiblemandatory
mxHardwareVpdIndex
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.1INTEGERread-onlymandatory
mxHardwareVpdBayNumber
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.2OCTET STRINGread-onlymandatory
mxHardwareVpdManufacturingId
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.3OCTET STRINGread-onlymandatory
mxHardwareVpdFruNumber
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.4OCTET STRINGread-onlymandatory
mxHardwareVpdHardwareRevision
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.5INTEGERread-onlymandatory
mxHardwareVpdUuid
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.8OCTET STRINGread-onlymandatory
mxHardwareVpdManufDate
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.9OCTET STRINGread-onlymandatory
mxHardwareVpdPartNumber
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.10OCTET STRINGread-onlymandatory
mxHardwareVpdFruSerial
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.11OCTET STRINGread-onlymandatory
mxHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.12OCTET STRINGread-onlymandatory
mxHardwareVpdProductId
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.13OCTET STRINGread-onlymandatory
mxHardwareVpdSubManufacturerId
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.14OCTET STRINGread-onlymandatory
mxHardwareVpdClei
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.15OCTET STRINGread-onlymandatory
mxHardwareVpdHardwareRevisionString
OBJECT-TYPE
Multiplexer Expansion Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.16OCTET STRINGread-onlymandatory
stmHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.18
stmHardwareVpdTable
OBJECT-TYPE
Table of the Storage Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1not-accessiblemandatory
stmHardwareVpdEntry
OBJECT-TYPE
Storage Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1not-accessiblemandatory
stmHardwareVpdIndex
OBJECT-TYPE
Storage Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.1INTEGERread-onlymandatory
stmHardwareVpdBayNumber
OBJECT-TYPE
Storage Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.2OCTET STRINGread-onlymandatory
stmHardwareVpdManufacturingId
OBJECT-TYPE
Storage Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.3OCTET STRINGread-onlymandatory
stmHardwareVpdFruNumber
OBJECT-TYPE
Storage Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.4OCTET STRINGread-onlymandatory
stmHardwareVpdHardwareRevision
OBJECT-TYPE
Storage Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.5INTEGERread-onlymandatory
stmHardwareVpdUuid
OBJECT-TYPE
Storage Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.8OCTET STRINGread-onlymandatory
stmHardwareVpdManufDate
OBJECT-TYPE
Storage Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.9OCTET STRINGread-onlymandatory
stmHardwareVpdPartNumber
OBJECT-TYPE
Storage Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.10OCTET STRINGread-onlymandatory
stmHardwareVpdFruSerial
OBJECT-TYPE
Storage Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.11OCTET STRINGread-onlymandatory
stmHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Storage Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.12OCTET STRINGread-onlymandatory
stmHardwareVpdProductId
OBJECT-TYPE
Storage Module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.13OCTET STRINGread-onlymandatory
stmHardwareVpdSubManufacturerId
OBJECT-TYPE
Storage Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.14OCTET STRINGread-onlymandatory
stmHardwareVpdClei
OBJECT-TYPE
Storage Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.15OCTET STRINGread-onlymandatory
stmHardwareVpdHardwareRevisionString
OBJECT-TYPE
Storage Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.16OCTET STRINGread-onlymandatory
stmFirmwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.19
stmFirmwareVpdTable
OBJECT-TYPE
Table of the Storage Module firmware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1not-accessiblemandatory
stmFirmwareVpdEntry
OBJECT-TYPE
Storage Module firmware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1not-accessiblemandatory
stmFirmwareVpdIndex
OBJECT-TYPE
Storage Module firmware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.1INTEGERread-onlymandatory
stmFirmwareVpdType
OBJECT-TYPE
Storage Module firmware VPD type. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.2OCTET STRINGread-onlymandatory
stmFirmwareVpdBuildId
OBJECT-TYPE
Storage Module firmware VPD build ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.3OCTET STRINGread-onlymandatory
stmFirmwareVpdReleaseDate
OBJECT-TYPE
Storage Module firmware VPD release date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.4OCTET STRINGread-onlymandatory
stmFirmwareVpdRevision
OBJECT-TYPE
Storage Module firmware VPD revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.5OCTET STRINGread-onlymandatory
bbuHardwareVpd
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.21
bbuHardwareVpdTable
OBJECT-TYPE
Table of the Battery Backup Unit hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1not-accessiblemandatory
bbuHardwareVpdEntry
OBJECT-TYPE
Battery Backup Unit hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1not-accessiblemandatory
bbuHardwareVpdIndex
OBJECT-TYPE
Battery Backup Unit hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.1INTEGERread-onlymandatory
bbuHardwareVpdBayNumber
OBJECT-TYPE
Battery Backup Unit hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.2OCTET STRINGread-onlymandatory
bbuHardwareVpdManufacturingId
OBJECT-TYPE
Battery Backup Unit hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.3OCTET STRINGread-onlymandatory
bbuHardwareVpdFruNumber
OBJECT-TYPE
Battery Backup Unit hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.4OCTET STRINGread-onlymandatory
bbuHardwareVpdHardwareRevision
OBJECT-TYPE
Battery Backup Unit hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.5INTEGERread-onlymandatory
bbuHardwareVpdUuid
OBJECT-TYPE
Battery Backup Unit hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.8OCTET STRINGread-onlymandatory
bbuHardwareVpdManufDate
OBJECT-TYPE
Battery Backup Unit hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.9OCTET STRINGread-onlymandatory
bbuHardwareVpdPartNumber
OBJECT-TYPE
Battery Backup Unit hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.10OCTET STRINGread-onlymandatory
bbuHardwareVpdFruSerial
OBJECT-TYPE
Battery Backup Unit hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.11OCTET STRINGread-onlymandatory
bbuHardwareVpdManufacturingIDNumber
OBJECT-TYPE
Battery Backup Unit hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.12OCTET STRINGread-onlymandatory
bbuHardwareVpdProductId
OBJECT-TYPE
Battery Backup Unit hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.13OCTET STRINGread-onlymandatory
bbuHardwareVpdSubManufacturerId
OBJECT-TYPE
Battery Backup Unit hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.14OCTET STRINGread-onlymandatory
bbuHardwareVpdClei
OBJECT-TYPE
Battery Backup Unit hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.15OCTET STRINGread-onlymandatory
inventoryManagementActivityVpdTable
OBJECT-TYPE
Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22not-accessiblemandatory
inventoryManagementActivityVpdEntry
OBJECT-TYPE
System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1not-accessiblemandatory
componentLevelActivityVpdIndex
OBJECT-TYPE
System component level VPD activity log index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.1INTEGERread-onlymandatory
componentLevelActivityVpdFruNumber
OBJECT-TYPE
System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.2OCTET STRINGread-onlymandatory
componentLevelActivityVpdSerialNumber
OBJECT-TYPE
System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.3OCTET STRINGread-onlymandatory
componentLevelActivityVpdManufacturingId
OBJECT-TYPE
System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.4OCTET STRINGread-onlymandatory
componentLevelActivityVpdBayNumber
OBJECT-TYPE
System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.5OCTET STRINGread-onlymandatory
componentLevelActivityVpdAction
OBJECT-TYPE
System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.9OCTET STRINGread-onlymandatory
componentLevelActivityVpdTimestamp
OBJECT-TYPE
System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.10OCTET STRINGread-onlymandatory
componentLevelActivityVpdModuleName
OBJECT-TYPE
The module name which this row is associated with. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.12OCTET STRINGread-onlymandatory
reloadVpdData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.21.23
reloadAllVpdData
OBJECT-TYPE
Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.1INTEGER {execute(1)}read-writemandatory
reloadFwVpdData
OBJECT-TYPE
Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.2INTEGER {execute(1)}read-writemandatory
reloadHwVpdData
OBJECT-TYPE
Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.3INTEGER {execute(1)}read-writemandatory
reloadMACAddress
OBJECT-TYPE
Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.4INTEGER {execute(1)}read-writemandatory
reloadWwnGuidVpdData
OBJECT-TYPE
Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.5INTEGER {execute(1)}read-writemandatory
airFilter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.22
passiveAirFilter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.22.1
passiveAirFilterStatus
OBJECT-TYPE
Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. The reset command is only applicable in BladeCenter Telco Refresh and it will restart the Fouled Filter Detection settings. NOTE: This MIB object is only applicable for BladeCenter S, BladeCenter E Refresh, and BladeCenter Telco Refresh.
1.3.6.1.4.1.2.3.51.2.2.22.1.1INTEGER {disabled(0), enabled(1), reset(2)}read-writemandatory
passiveAirFilterMonthFreq
OBJECT-TYPE
The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only.
1.3.6.1.4.1.2.3.51.2.2.22.1.2INTEGER {oneMonth(1), threeMonths(3), sixMonths(6)}read-writemandatory
passiveAirFilterReplaceDate
OBJECT-TYPE
The scheduled replacement date of the air filter. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only.
1.3.6.1.4.1.2.3.51.2.2.22.1.3OCTET STRING (SIZE(0..30))read-onlymandatory
componentInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23
componentInventory
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23.1
componentInventoryTable
OBJECT-TYPE
Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry.
1.3.6.1.4.1.2.3.51.2.2.23.1.1not-accessiblemandatory
componentInventoryEntry
OBJECT-TYPE
Component inventory information.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1not-accessiblemandatory
componentInventoryTopologyPath
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentInventoryInstance
OBJECT-TYPE
The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2INTEGERread-onlymandatory
componentInventoryDescription
OBJECT-TYPE
A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3OCTET STRINGread-onlymandatory
componentInventoryMachineTypeModel
OBJECT-TYPE
The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4OCTET STRINGread-onlymandatory
componentInventoryMachineSerial
OBJECT-TYPE
The machine serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5OCTET STRINGread-onlymandatory
componentInventoryAssetID
OBJECT-TYPE
The asset identifier of this component, typically set by some other authority than the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6OCTET STRINGread-onlymandatory
componentInventoryPartNumber
OBJECT-TYPE
The part number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7OCTET STRINGread-onlymandatory
componentInventoryFRUNumber
OBJECT-TYPE
The Field Replaceable Unit (FRU) number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8OCTET STRINGread-onlymandatory
componentInventoryFRUSerialNumber
OBJECT-TYPE
The Field Replaceable Unit (FRU) serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9OCTET STRINGread-onlymandatory
componentInventoryManufactureID
OBJECT-TYPE
The text description of the manufacturer of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10OCTET STRINGread-onlymandatory
componentInventoryHardwareRevision
OBJECT-TYPE
The hardware revision number of the this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11OCTET STRINGread-onlymandatory
componentInventoryManufactureDate
OBJECT-TYPE
The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12OCTET STRINGread-onlymandatory
componentInventoryUUID
OBJECT-TYPE
The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13OCTET STRINGread-onlymandatory
componentInventoryProductID
OBJECT-TYPE
The product identifier of the component assigned by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14OCTET STRINGread-onlymandatory
componentInventorySubManufactureID
OBJECT-TYPE
The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15OCTET STRINGread-onlymandatory
componentInventoryCLEI
OBJECT-TYPE
The Common Language Equipment Identifier (CLEI) of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16OCTET STRINGread-onlymandatory
componentInventoryAssetTag
OBJECT-TYPE
The asset tag of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17OCTET STRINGread-onlymandatory
componentInventorySpeed
OBJECT-TYPE
A speed designation for the component, for example, processor speed.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18OCTET STRINGread-onlymandatory
componentInventoryIdentifier
OBJECT-TYPE
A unique identifier assigned by the manufacturer to the component, for example, a processor ID.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19OCTET STRINGread-onlymandatory
componentInventorySize
OBJECT-TYPE
A size designation for the component, for example, a memory DIMM size or hard drive capacity.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20INTEGERread-onlymandatory
componentInventoryMemoryType
OBJECT-TYPE
The architecture specification of a memory device.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21INTEGER {fpmdram(1), edo(2), edodram(3), sdram(4), multiplexedram(5), ddrsgram(6), ddrsdram(7), ddr2sdrm(8), ddr3sdram(9)}read-onlymandatory
componentInventoryProductName
OBJECT-TYPE
The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22OCTET STRINGread-onlymandatory
componentInventoryProductVersion
OBJECT-TYPE
The product version assigned by the manufacturer for this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23OCTET STRINGread-onlymandatory
componentInventoryProcessorType
OBJECT-TYPE
The type designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24INTEGER {other(1), unknown(2), central(3), math(4), dsp(5), video(6)}read-onlymandatory
componentInventoryProcessorFamily
OBJECT-TYPE
The family designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25OCTET STRINGread-onlymandatory
componentInventoryProcessorCores
OBJECT-TYPE
The number of cores present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26OCTET STRINGread-onlymandatory
componentInventoryProcessorThreads
OBJECT-TYPE
The number of threads present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27OCTET STRINGread-onlymandatory
componentInventoryProcessorL1DCache
OBJECT-TYPE
The level 1 data cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28OCTET STRINGread-onlymandatory
componentInventoryProcessorL1ICache
OBJECT-TYPE
The level 1 instruction cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29OCTET STRINGread-onlymandatory
componentInventoryProcessorL2Cache
OBJECT-TYPE
The level 2 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30OCTET STRINGread-onlymandatory
componentInventoryProcessorL3Cache
OBJECT-TYPE
The level 3 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31OCTET STRINGread-onlymandatory
componentInventoryProcessorVoltage
OBJECT-TYPE
The voltage rating for a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32OCTET STRINGread-onlymandatory
componentInventoryProcessorExtClock
OBJECT-TYPE
The external clock speed of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33OCTET STRINGread-onlymandatory
componentInventoryProcessorDataWidth
OBJECT-TYPE
The maximum data bus width capability of a processor component, expressed typically in bits.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34OCTET STRINGread-onlymandatory
componentInventoryManufactureIDNum
OBJECT-TYPE
The identification number assigned for the component by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35INTEGERread-onlymandatory
componentFirmware
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.2.23.2
componentFirmwareTable
OBJECT-TYPE
Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry.
1.3.6.1.4.1.2.3.51.2.2.23.2.1not-accessiblemandatory
componentFirmwareEntry
OBJECT-TYPE
Component firmware information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1not-accessiblemandatory
componentFirmwareTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentFirmwareIndex
OBJECT-TYPE
Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2INTEGERread-onlymandatory
componentFirmwareComponentInstance
OBJECT-TYPE
The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3INTEGERread-onlymandatory
componentFirmwareComponentDescription
OBJECT-TYPE
A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4OCTET STRINGread-onlymandatory
componentFirmwareType
OBJECT-TYPE
A text description of the type of firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5OCTET STRINGread-onlymandatory
componentFirmwareBuildID
OBJECT-TYPE
A text description of the build identifier for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6OCTET STRINGread-onlymandatory
componentFirmwareReleaseDate
OBJECT-TYPE
A text description of the release date for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7OCTET STRINGread-onlymandatory
componentFirmwareFilename
OBJECT-TYPE
A text description of the filename of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8OCTET STRINGread-onlymandatory
componentFirmwareRevision
OBJECT-TYPE
A text description of the revision level of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9OCTET STRINGread-onlymandatory
componentFirmwareRevisionMajor
OBJECT-TYPE
A numeric identifier of the revision major number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10INTEGERread-onlymandatory
componentFirmwareRevisionMinor
OBJECT-TYPE
A numeric identifier of the revision minor number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11INTEGERread-onlymandatory
componentFirmwareLevelStatus
OBJECT-TYPE
The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID).
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12OCTET STRINGread-onlymandatory
componentFirmwarePendingBuildID
OBJECT-TYPE
A text description of the build identifier for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13OCTET STRINGread-onlymandatory
componentFirmwarePendingReleaseDate
OBJECT-TYPE
A text description of the release date for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14OCTET STRINGread-onlymandatory
componentFirmwarePendingRevision
OBJECT-TYPE
A text description of the revision level of this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15OCTET STRINGread-onlymandatory
componentFirmwareTypeID
OBJECT-TYPE
Indicates the type of firmware load with a numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20INTEGER {bladeFwBios(1), bladeDiagnostics(2), bladeSysMgmtProcessor(3), bladeFpga(4), bladecKVM(5), switchModuleMainAppl1(41), switchModuleMainAppl2(42), switchModuleBootROM(43), mgmtModuleMainAppl(61), mgmtModuleMainApplPendingRestart(62), fanController(81), unknown(255)}read-onlymandatory
componentInventoryReady
OBJECT-TYPE
When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades have completed initialization and the inventory information has been provided to the AMM. Note that due to blades that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period. A more granular, per-blade status is available via the bladeSystemStatusTable
1.3.6.1.4.1.2.3.51.2.2.23.3INTEGER {notReady(0), ready(1)}read-onlymandatory
componentDriveTable
OBJECT-TYPE
Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table.
1.3.6.1.4.1.2.3.51.2.2.23.10not-accessiblemandatory
componentDriveEntry
OBJECT-TYPE
Component drive information.
1.3.6.1.4.1.2.3.51.2.2.23.10.1not-accessiblemandatory
componentDriveTopologyPath
OBJECT-TYPE
The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card
1.3.6.1.4.1.2.3.51.2.2.23.10.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentDriveDescription
OBJECT-TYPE
A short text string describing the particular drive on the component.
1.3.6.1.4.1.2.3.51.2.2.23.10.1.2OCTET STRINGread-onlymandatory
errorLogs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.3
eventLog
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.3.4
readEventLogTable
OBJECT-TYPE
Table of event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.2not-accessiblemandatory
readEventLogEntry
OBJECT-TYPE
Event log table entry
1.3.6.1.4.1.2.3.51.2.3.4.2.1not-accessiblemandatory
readEventLogIndex
OBJECT-TYPE
The event log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.1INTEGERread-onlymandatory
readEventLogString
OBJECT-TYPE
A string of data detailing an event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.2OCTET STRINGread-onlymandatory
clearEventLog
OBJECT-TYPE
Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.3INTEGER {execute(1)}read-writemandatory
monitorLogStateEvents
OBJECT-TYPE
If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out.
1.3.6.1.4.1.2.3.51.2.3.4.4INTEGER {disabled(0), enabled(1)}read-writemandatory
readEnhancedEventLogTable
OBJECT-TYPE
Table of enhanced event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.6not-accessiblemandatory
readEnhancedEventLogEntry
OBJECT-TYPE
Enhaced Event log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.6.1not-accessiblemandatory
readEnhancedEventLogNumber
OBJECT-TYPE
The event log number for the enhanced event log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.1INTEGERread-onlymandatory
readEnhancedEventLogAttribute
OBJECT-TYPE
A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.2OCTET STRINGread-onlymandatory
readEnhancedEventLogMessage
OBJECT-TYPE
A string of data detailing an event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.3OCTET STRINGread-onlymandatory
readAuditLogTable
OBJECT-TYPE
Table of audit log entry information. Audit log includes the logs whose source is 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.10not-accessiblemandatory
readAuditLogEntry
OBJECT-TYPE
Audit log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.10.1not-accessiblemandatory
readAuditLogNumber
OBJECT-TYPE
The audit log number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.1INTEGERread-onlymandatory
readAuditLogAttribute
OBJECT-TYPE
A string of data detailing an audit eventlog's attribute. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.2OCTET STRINGread-onlymandatory
readAuditLogMessage
OBJECT-TYPE
A string of data detailing an audit event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.3OCTET STRINGread-onlymandatory
clearAuditLog
OBJECT-TYPE
Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.11INTEGER {execute(1)}read-writemandatory
readSystemLogTable
OBJECT-TYPE
Table of system log entry information. System log includes the logs whose source is other than 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.12not-accessiblemandatory
readSystemLogEntry
OBJECT-TYPE
System log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.12.1not-accessiblemandatory
readSystemLogNumber
OBJECT-TYPE
The system log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.1INTEGERread-onlymandatory
readSystemLogAttribute
OBJECT-TYPE
A string of data detailing an system event log's attribute. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.2OCTET STRINGread-onlymandatory
readSystemLogMessage
OBJECT-TYPE
A string of data detailing an system event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.3OCTET STRINGread-onlymandatory
clearSystemLog
OBJECT-TYPE
Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.13INTEGER {execute(1)}read-writemandatory
configureSP
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4
remoteAccessConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1
generalRemoteCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1
remoteAlertRetryDelay
OBJECT-TYPE
Number in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.2.4.1.1.3INTEGER {noDelay(0), oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)}read-writemandatory
remoteAlertRetryCount
OBJECT-TYPE
Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.2.3.51.2.4.1.1.4INTEGER {noretry(0), retry1(1), retry2(2), retry3(3), retry4(4), retry5(5), retry6(6), retry7(7), retry8(8)}read-writemandatory
remoteAlertEntryDelay
OBJECT-TYPE
Number in seconds to delay between entries if sending a remote alert is unsuccessful. NOTE: This object is no longer supported. However, for compatibilities sake, a value of (255) is returned when read. Also, write access has been removed.
1.3.6.1.4.1.2.3.51.2.4.1.1.5INTEGER {noDelay(0), oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240)}read-onlydeprecated
remoteAccessTamperDelay
OBJECT-TYPE
This value is no longer supported and has been replaced by 'lockoutPeriod'.
1.3.6.1.4.1.2.3.51.2.4.1.1.6INTEGER {nowait(0), oneMinute(1), twoMinutes(2), threeMinutes(3), fourMinutes(4), fiveMinutes(5), sixMinutes(6), sevenMinutes(7), tenMinutes(10), fifteenMinutes(15), twentyMinutes(20), thirtyMinutes(30), sixtyMinutes(60), oneTwentyMinutes(120), oneEightyMinutes(180), twoFortyMinutes(240)}read-writedeprecated
userAuthenticationMethod
OBJECT-TYPE
Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified.
1.3.6.1.4.1.2.3.51.2.4.1.1.7INTEGER {localOnly(0), ldapOnly(1), localFirstThenLdap(2), ldapFirstThenLocal(3)}read-writemandatory
maxSessionsPerLDAPUser
OBJECT-TYPE
The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20.
1.3.6.1.4.1.2.3.51.2.4.1.1.9INTEGERread-writemandatory
authenticationLoggingTimeout
OBJECT-TYPE
Use this option to set how long, in seconds, AMM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events.
1.3.6.1.4.1.2.3.51.2.4.1.1.10INTEGER {logAll(0), fiveSeconds(1), thirtySeconds(2), oneMinute(3), fiveMinutes(4), tenMinutes(5), thirtyMinutes(6), oneHour(7), twelveHours(8), oneDay(9), logNone(255)}read-writemandatory
trackingIP
OBJECT-TYPE
This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'.
1.3.6.1.4.1.2.3.51.2.4.1.1.11INTEGER {disable(0), enable(1)}read-writemandatory
accountSecurityManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1.20
accountSecurityLevel
OBJECT-TYPE
The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.1INTEGER {legacy(0), high(1), custom(2)}read-writemandatory
customSecuritySettings
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2
loginPasswordRequired
OBJECT-TYPE
If enabled, all users require a login password to access the AMM. If disabled, empty password is allowed and complex password rules will be disabled automatically. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
passwordExpirationPeriod
OBJECT-TYPE
The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2INTEGERread-writemandatory
defaultAdminPasswordExpired
OBJECT-TYPE
If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3INTEGER {disabled(0), enabled(1)}read-writemandatory
minimumPasswordReuseCycle
OBJECT-TYPE
The number of unique passwords a user must choose before reusing a password. The default value is none.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4INTEGER {none(0), onePassword(1), twoPasswords(2), threePasswords(3), fourPasswords(4), fivePasswords(5)}read-writemandatory
complexPasswordRules
OBJECT-TYPE
If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The rules are as follows: Passwords must be a minimum of eight characters. Passwords must not be a repeat or reverse of the associated login id. Passwords must be no more than three of the same characters used consecutively. Passwords must contain at least three of the following combinations: At least one lower case alphanumeric character. At least one upper case alphanumeric character. At least one numeric character. At least one special character. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5INTEGER {disabled(0), enabled(1)}read-writemandatory
minimumDiffCharsPassword
OBJECT-TYPE
The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0)
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6INTEGER {none(0), oneChar(1), twoChars(2), threeChars(3), fourChars(4), fiveChars(5), sixChars(6), sevenChars(7), eightChars(8), nineChars(9), tenChars(10), elevenChars(11), twelveChars(12), thirteenChars(13), fourteenChars(14), fifteenChars(15)}read-writemandatory
changePasswordFirstAccess
OBJECT-TYPE
If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7INTEGER {disabled(0), enabled(1)}read-writemandatory
inactivityAlertPeriod
OBJECT-TYPE
The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8INTEGERread-writemandatory
inactivityAlertDisablePeriod
OBJECT-TYPE
The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9INTEGERread-writemandatory
lockoutPeriod
OBJECT-TYPE
The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10INTEGERread-writemandatory
maxLoginFailures
OBJECT-TYPE
The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11INTEGER {none(0), oneTime(1), twoTimes(2), threeTimes(3), fourTimes(4), fiveTimes(5), sixTimes(6), sevenTimes(7), eightTimes(8), nineTimes(9), tenTimes(10)}read-writemandatory
passwordChangeInterval
OBJECT-TYPE
A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12INTEGERread-writemandatory
serialPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.2
portBaud
OBJECT-TYPE
Baud rate for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.1INTEGER {baud2400(0), baud4800(1), baud9600(3), baud19200(7), baud38400(15), baud57600(23)}read-writemandatory
portParity
OBJECT-TYPE
Parity setting for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.2INTEGER {none(0), odd(1), even(3), mark(5), space(7)}read-writemandatory
portStopBits
OBJECT-TYPE
Number of stop bits for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.3INTEGER {oneStopbit(0), twoOrOnePtFive(1)}read-writemandatory
remoteAlertIds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.3
remoteAlertIdsTable
OBJECT-TYPE
Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients.
1.3.6.1.4.1.2.3.51.2.4.1.3.1not-accessiblemandatory
remoteAlertIdsEntry
OBJECT-TYPE
Remote alert entries.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1not-accessiblemandatory
remoteAlertIdEntryIndex
OBJECT-TYPE
Index for remote alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1INTEGERread-onlymandatory
remoteAlertIdEntryStatus
OBJECT-TYPE
Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2INTEGER {invalid(0), disabledAndValid(1), enabledAndValid(2)}read-writemandatory
remoteAlertIdEntryIpOrHostAddress
OBJECT-TYPE
A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3OCTET STRING (SIZE(0..50))read-writemandatory
remoteAlertIdEntryTextDescription
OBJECT-TYPE
A null terminated string that contains a text description of this entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4OCTET STRING (SIZE(0..50))read-writemandatory
remoteAlertIdEntryNotificationType
OBJECT-TYPE
Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), ibmDirectorOverLAN for a LAN alert sent over ethernet to IBM director, snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5INTEGER {unknown(0), snmpOverLan(4), emailOverLan(5), ibmDirectorOverLAN(8)}read-writemandatory
remoteAlertIdEmailAddr
OBJECT-TYPE
A null terminated string that contains an E-Mail Address. For example, 'jeb@us.ibm.com'. Used only for an E-mail over LAN or E-Mail over PPP notification type.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9OCTET STRING (SIZE(0..64))read-writemandatory
remoteAlertIdEntrySelectiveAlert
OBJECT-TYPE
Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13INTEGER {critOnlyAlerts(0), allAlerts(1)}read-writemandatory
generateTestAlert
OBJECT-TYPE
Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. The text portion of the alert will contain 'Application Posted Alert to MM'. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.3.30INTEGER {execute(1)}read-writemandatory
remoteAccessIds
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.4
remoteAccessIdsTable
OBJECT-TYPE
Table of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice.
1.3.6.1.4.1.2.3.51.2.4.1.4.1not-accessiblemandatory
remoteAccessIdsEntry
OBJECT-TYPE
Remote access entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1not-accessiblemandatory
remoteAccessIdEntryIndex
OBJECT-TYPE
Index for Remote access entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1INTEGER (0..255)read-onlymandatory
remoteAccessIdEntryUserId
OBJECT-TYPE
Remote access entry null terminated string that contains the user-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2OCTET STRING (SIZE(0..15))read-writemandatory
remoteAccessIdEntryPassword
OBJECT-TYPE
Remote access password. The password must contain at least one alphabetic and one non-alphabetic character and be at least 5 characters long, or you can leave the password field blank to set an empty password. NOTE: Value returned by the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3OCTET STRING (SIZE(0..15))read-writemandatory
remoteAccessIdEntryEncodedLoginPw
OBJECT-TYPE
Used only for configuration save/restore. A null terminated string containing an encoded concatenation of the login ID and password separated by an ':'. This object is no longer supported and will return a string of asterisks
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.7OCTET STRING (SIZE(0..36))read-writedeprecated
remoteAccessIdEntryRole
OBJECT-TYPE
Indicates if user has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10OCTET STRINGread-onlymandatory
remoteAccessIdEntryLoggedIn
OBJECT-TYPE
Indicates if user is currently logged in or not.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryLastLogin
OBJECT-TYPE
Timestamp for the last successful login by the user.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12OCTET STRINGread-onlymandatory
remoteAccessIdEntryPwdCompliant
OBJECT-TYPE
Indicates if user complies with all of the password rules currently in effect.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryPwdExp
OBJECT-TYPE
The number of days until the user's current password expires.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14OCTET STRINGread-onlymandatory
remoteAccessIdEntryDormant
OBJECT-TYPE
Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15INTEGER {no(0), yes(1)}read-onlymandatory
remoteAccessIdEntryState
OBJECT-TYPE
Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16INTEGER {disabled(0), active(1), locked(2)}read-onlymandatory
remoteAccessIdEntryAction
OBJECT-TYPE
Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17INTEGER {disable(0), enable(1), unlock(2), notApplicable(255)}read-writemandatory
remoteAccessIdEntrySessionCount
OBJECT-TYPE
The number of sessions the user is currently logged in to.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18INTEGERread-onlymandatory
remoteAccessIdEntryMaxSessions
OBJECT-TYPE
The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19INTEGERread-writemandatory
remoteAccessUserAuthorityLevelTable
OBJECT-TYPE
Table of user authority level profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.2not-accessiblemandatory
remoteAccessUserAuthorityLevelEntry
OBJECT-TYPE
User authority level entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1not-accessiblemandatory
ualIndex
OBJECT-TYPE
Index for User Authority Level entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.1INTEGER (0..255)read-onlymandatory
ualId
OBJECT-TYPE
User ID
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
ualSupervisor
OBJECT-TYPE
User has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
ualReadOnly
OBJECT-TYPE
User has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
ualAccountManagement
OBJECT-TYPE
User can add/modify/delete users and change the global login settings in the Login Profiles panel.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
ualConsoleAccess
OBJECT-TYPE
User can access the remote console.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
ualConsoleAndVirtualMediaAccess
OBJECT-TYPE
User can access both the remote console and the virtual media feature.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
ualServerPowerAccess
OBJECT-TYPE
User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
ualAllowClearLog
OBJECT-TYPE
User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
ualAdapterBasicConfig
OBJECT-TYPE
User can modify configuration parameters in the System Settings and Alerts panels.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
ualAdapterNetworkAndSecurityConfig
OBJECT-TYPE
User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
ualAdapterAdvancedConfig
OBJECT-TYPE
User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the RSA, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAccessRBSroleTable
OBJECT-TYPE
Table of RBS User Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.3not-accessiblemandatory
remoteAccessRBSroleEntry
OBJECT-TYPE
User Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1not-accessiblemandatory
roleIndex
OBJECT-TYPE
Index for RBS User Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1INTEGER (0..255)read-onlymandatory
roleId
OBJECT-TYPE
User ID
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
rbsSupervisor
OBJECT-TYPE
User has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsOperator
OBJECT-TYPE
User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisOperator
OBJECT-TYPE
User has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisAccountManagement
OBJECT-TYPE
User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisLogManagement
OBJECT-TYPE
User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisConfiguration
OBJECT-TYPE
User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsChassisAdministration
OBJECT-TYPE
User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeOperator
OBJECT-TYPE
User has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeRemotePresence
OBJECT-TYPE
User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeConfiguration
OBJECT-TYPE
User can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeAdministration
OBJECT-TYPE
User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleOperator
OBJECT-TYPE
User has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleConfiguration
OBJECT-TYPE
User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitchModuleAdministration
OBJECT-TYPE
User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBladeRemotePresenseVideo
OBJECT-TYPE
User can browser Remote Control web panel and remote blade video. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.17INTEGER {disabled(0), enabled(1)}read-writedeprecated
rbsBladeRemotePresenseKVM
OBJECT-TYPE
User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.18INTEGER {disabled(0), enabled(1)}read-writedeprecated
rbsBladeRemotePresenseRdriveR
OBJECT-TYPE
User can mount remote blade driver, and have read access only. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.19INTEGER {disabled(0), enabled(1)}read-writedeprecated
rbsBladeRemotePresenseRdriveRW
OBJECT-TYPE
User can mount remote blade driver and have read/write access. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.20INTEGER {disabled(0), enabled(1)}read-writedeprecated
rbsChassisRemotePresenseRdoc
OBJECT-TYPE
User has ability to upload/delete own image to RDOC and also can start remote control web panel. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.21INTEGER {disabled(0), enabled(1)}read-writedeprecated
rbsRemotePresenceSupervisor
OBJECT-TYPE
User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote driver read/write, upload/delete himself and other's image to RDOC. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.22INTEGER {disabled(0), enabled(1)}read-writedeprecated
remoteAccessRBSscopeTable
OBJECT-TYPE
Table of RBS User Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.4not-accessiblemandatory
remoteAccessRBSscopeEntry
OBJECT-TYPE
User Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1not-accessiblemandatory
scopeIndex
OBJECT-TYPE
Index for RBS User Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1INTEGER (0..255)read-onlymandatory
scopeId
OBJECT-TYPE
User ID
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
rbsChassis
OBJECT-TYPE
User has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade1
OBJECT-TYPE
User has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade2
OBJECT-TYPE
User has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade3
OBJECT-TYPE
User has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade4
OBJECT-TYPE
User has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade5
OBJECT-TYPE
User has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade6
OBJECT-TYPE
User has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade7
OBJECT-TYPE
User has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade8
OBJECT-TYPE
User has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade9
OBJECT-TYPE
User has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade10
OBJECT-TYPE
User has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade11
OBJECT-TYPE
User has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade12
OBJECT-TYPE
User has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade13
OBJECT-TYPE
User has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsBlade14
OBJECT-TYPE
User has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch1
OBJECT-TYPE
User has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch2
OBJECT-TYPE
User has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch3
OBJECT-TYPE
User has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch4
OBJECT-TYPE
User has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch5
OBJECT-TYPE
User has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch6
OBJECT-TYPE
User has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch7
OBJECT-TYPE
User has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch8
OBJECT-TYPE
User has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch9
OBJECT-TYPE
User has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26INTEGER {disabled(0), enabled(1)}read-writemandatory
rbsSwitch10
OBJECT-TYPE
User has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27INTEGER {disabled(0), enabled(1)}read-writemandatory
userInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.5
cli
OBJECT-TYPE
Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.1INTEGER {disabled(0), telnet-only(1), ssh-only(2), enabled(3)}read-writemandatory
snmp
OBJECT-TYPE
Enable/Disable SNMP v1 and v3 access to the MM.
1.3.6.1.4.1.2.3.51.2.4.1.5.2INTEGER {disabled(0), v1-only(1), v3-only(2), enabled(3)}read-writemandatory
tcm
OBJECT-TYPE
Enable/Disable TCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode.
1.3.6.1.4.1.2.3.51.2.4.1.5.3INTEGER (0..20)read-writemandatory
web
OBJECT-TYPE
Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser.
1.3.6.1.4.1.2.3.51.2.4.1.5.4INTEGER {disabled(0), enabled(1)}read-writemandatory
stcm
OBJECT-TYPE
Enable/Disable STCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.1.5.5INTEGER (0..20)read-writemandatory
mmSshClientAuth
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.6
mmSshClientAuthPubKeyTable
OBJECT-TYPE
A table that contains client authentication public key information.
1.3.6.1.4.1.2.3.51.2.4.1.6.1not-accessiblemandatory
mmSshClientAuthPubKeyEntry
OBJECT-TYPE
A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1not-accessiblemandatory
mmSshClientAuthRemoteAccessIdIndex
OBJECT-TYPE
The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1INTEGERnot-accessiblemandatory
mmSshClientAuthPubKeyIndex
OBJECT-TYPE
The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2INTEGERnot-accessiblemandatory
mmSshClientAuthPubKeyType
OBJECT-TYPE
The type of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3INTEGER {sshDss(1), sshRsa(2)}read-onlymandatory
mmSshClientAuthPubKeySize
OBJECT-TYPE
The size of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)}read-onlymandatory
mmSshClientAuthPubKeyFingerprint
OBJECT-TYPE
The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5OCTET STRINGread-onlymandatory
mmSshClientAuthPubKeyAcceptFrom
OBJECT-TYPE
This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyComment
OBJECT-TYPE
This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyAction
OBJECT-TYPE
import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the AMM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8INTEGER {import(1), export(2)}read-writemandatory
mmSshClientAuthPubKeyEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9EntryStatusread-writemandatory
mmSshClientAuthPubKeyUnused
OBJECT-TYPE
The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration.
1.3.6.1.4.1.2.3.51.2.4.1.6.2INTEGERread-onlymandatory
mmSshClientAuthPubKeyTftpServer
OBJECT-TYPE
IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2).
1.3.6.1.4.1.2.3.51.2.4.1.6.3OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyFileName
OBJECT-TYPE
File name on the TFTP server of an SSH client authentication public key.
1.3.6.1.4.1.2.3.51.2.4.1.6.4OCTET STRINGread-writemandatory
mmSshClientAuthPubKeyFileFormat
OBJECT-TYPE
File format of SSH client authentication public key files imported from or exported to the TFTP file server.
1.3.6.1.4.1.2.3.51.2.4.1.6.5INTEGER {openSSH(1), rfc4716(2)}read-writemandatory
groupProfiles
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.1.7
groupIdsTable
OBJECT-TYPE
Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.1not-accessiblemandatory
groupIdsEntry
OBJECT-TYPE
Group ID entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1not-accessiblemandatory
groupIndex
OBJECT-TYPE
Index for Group IDs entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1INTEGER (0..255)read-onlymandatory
groupId
OBJECT-TYPE
Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2OCTET STRING (SIZE(0..16))read-writemandatory
groupRole
OBJECT-TYPE
Group Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3OCTET STRINGread-onlymandatory
groupEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9EntryStatusread-writemandatory
groupRBSroleTable
OBJECT-TYPE
Table of Group Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.2not-accessiblemandatory
groupRBSroleEntry
OBJECT-TYPE
Group Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1not-accessiblemandatory
groupRBSroleIndex
OBJECT-TYPE
Index for Group Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1INTEGER (0..255)read-onlymandatory
groupRBSroleId
OBJECT-TYPE
Group ID
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
groupRBSSupervisor
OBJECT-TYPE
Group has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSOperator
OBJECT-TYPE
Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.).
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisOperator
OBJECT-TYPE
Group has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisAccountManagement
OBJECT-TYPE
Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisLogManagement
OBJECT-TYPE
Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisConfiguration
OBJECT-TYPE
Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSChassisAdministration
OBJECT-TYPE
Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeOperator
OBJECT-TYPE
Group has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeRemotePresence
OBJECT-TYPE
Group has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeConfiguration
OBJECT-TYPE
Group can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBladeAdministration
OBJECT-TYPE
Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleOperator
OBJECT-TYPE
Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleConfiguration
OBJECT-TYPE
Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitchModuleAdministration
OBJECT-TYPE
Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSscopeTable
OBJECT-TYPE
Table of Group Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.3not-accessiblemandatory
groupRBSscopeEntry
OBJECT-TYPE
Group Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1not-accessiblemandatory
groupRBSscopeIndex
OBJECT-TYPE
Index for Group Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1INTEGER (0..255)read-onlymandatory
groupRBSscopeId
OBJECT-TYPE
Group ID
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2OCTET STRING (SIZE(0..16))read-onlymandatory
groupRBSChassis
OBJECT-TYPE
Group has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade1
OBJECT-TYPE
Group has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade2
OBJECT-TYPE
Group has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade3
OBJECT-TYPE
Group has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade4
OBJECT-TYPE
Group has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade5
OBJECT-TYPE
Group has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade6
OBJECT-TYPE
Group has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade7
OBJECT-TYPE
Group has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade8
OBJECT-TYPE
Group has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade9
OBJECT-TYPE
Group has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade10
OBJECT-TYPE
Group has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade11
OBJECT-TYPE
Group has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade12
OBJECT-TYPE
Group has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade13
OBJECT-TYPE
Group has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSBlade14
OBJECT-TYPE
Group has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch1
OBJECT-TYPE
Group has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch2
OBJECT-TYPE
Group has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch3
OBJECT-TYPE
Group has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch4
OBJECT-TYPE
Group has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch5
OBJECT-TYPE
Group has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch6
OBJECT-TYPE
Group has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch7
OBJECT-TYPE
Group has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch8
OBJECT-TYPE
Group has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch9
OBJECT-TYPE
Group has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26INTEGER {disabled(0), enabled(1)}read-writemandatory
groupRBSSwitch10
OBJECT-TYPE
Group has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlerts
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2
remoteAlertsCrit
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.1
critTemp
OBJECT-TYPE
Generate an alert if any of the monitored temperature sensors in the system exceed their critical threshold. NOTE: If a critical Temperature condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.1INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critVolt
OBJECT-TYPE
Generate a alert if any of the monitored power supply sensors in the system fall outside their specified critical operational range. NOTE: If a critical voltage condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.2INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critMultiBlower
OBJECT-TYPE
Generate an alert if multiple blowers used for cooling the system fail. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.4INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critPower
OBJECT-TYPE
Generate an alert if any of the system power supplies fail. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
critHardDrive
OBJECT-TYPE
Generate an alert if any of hard disk drives fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.6INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critVRM
OBJECT-TYPE
Generate an alert if any of VRM (voltage regulator modules) fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.7INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critMultipleSwitchModule
OBJECT-TYPE
Generate an alert if all switch modules fail or are removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.8INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critInvalidConfig
OBJECT-TYPE
Generate an alert if the hardware configuration is incompatible. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.1.9INTEGER {disabled(0), enabled(1)}read-onlydeprecated
critBlade
OBJECT-TYPE
Generate an alert for any critical error condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
critIO
OBJECT-TYPE
Generate an alert for any critical error condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
critStorage
OBJECT-TYPE
Generate an alert for any critical error condition on a Storage module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.4.2.1.12INTEGER {disabled(0), enabled(1)}read-writemandatory
critChassis
OBJECT-TYPE
Generate an alert for any critical error condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.1.13INTEGER {disabled(0), enabled(1)}read-writemandatory
critFan
OBJECT-TYPE
Generate an alert for any critical error condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.1.14INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlertsNonCrit
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.2
warnSingleBlower
OBJECT-TYPE
Generate an alert if one blower used for cooling the system fails. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.2.2INTEGER {disabled(0), enabled(1)}read-onlydeprecated
warnTemp
OBJECT-TYPE
Generate an alert if any of the monitored temperature sensors in the system exceed their warning threshold. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.2.3INTEGER {disabled(0), enabled(1)}read-onlydeprecated
warnVoltage
OBJECT-TYPE
Generate an alert if any of the monitored power supply sensors in the system fall outside their specified warning operational range. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.2.4INTEGER {disabled(0), enabled(1)}read-onlydeprecated
warnRedundantModule
OBJECT-TYPE
Generate an alert if any of the switch modules or management modules is failing or removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.2.6INTEGER {disabled(0), enabled(1)}read-onlydeprecated
warnMediaTrayKVMSwitch
OBJECT-TYPE
Generate an alert if the system detects a Media Tray or KVM switching failure. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.2.7INTEGER {disabled(0), enabled(1)}read-onlydeprecated
warnLogFull
OBJECT-TYPE
Generate an alert if the system log reaches 100% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.10INTEGER {disabled(0), enabled(1)}read-writemandatory
warnBlade
OBJECT-TYPE
Generate an alert for any warning condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.15INTEGER {disabled(0), enabled(1)}read-writemandatory
warnIO
OBJECT-TYPE
Generate an alert for any warning condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.16INTEGER {disabled(0), enabled(1)}read-writemandatory
warnStorage
OBJECT-TYPE
Generate an alert for any warning condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.17INTEGER {disabled(0), enabled(1)}read-writemandatory
warnPower
OBJECT-TYPE
Generate an alert for any warning condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.18INTEGER {disabled(0), enabled(1)}read-writemandatory
warnChassis
OBJECT-TYPE
Generate an alert for any warning condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.19INTEGER {disabled(0), enabled(1)}read-writemandatory
warnFan
OBJECT-TYPE
Generate an alert for any warning condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.2.20INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteAlertsSystem
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.2.3
systemPowerOff
OBJECT-TYPE
Generate an alert if the system is powered off. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.3.4INTEGER {disabled(0), enabled(1)}read-onlydeprecated
systemPowerOn
OBJECT-TYPE
Generate a alert if the system is powered on. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.3.5INTEGER {disabled(0), enabled(1)}read-onlydeprecated
systemPFA
OBJECT-TYPE
Generate a alert if the system hardware detects a Predictive Failure Analysis(PFA) on PFA enabled hardware. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.3.8INTEGER {disabled(0), enabled(1)}read-onlydeprecated
systemInventory
OBJECT-TYPE
Generate an alert if the a processor blade or media tray is added or removed. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.10INTEGER {disabled(0), enabled(1)}read-writemandatory
systemLog75PctFull
OBJECT-TYPE
Generate an alert if the system log reaches 75% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.11INTEGER {disabled(0), enabled(1)}read-writemandatory
networkChangeNotification
OBJECT-TYPE
Generate an alert if the SP has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.12INTEGER {disabled(0), enabled(1)}read-writemandatory
systemBladeThrottling
OBJECT-TYPE
Generate an alert if any of the server blades are throttling. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.3.13INTEGER {disabled(0), enabled(1)}read-onlydeprecated
systemPowerManagement
OBJECT-TYPE
Generate an alert if the system detects a power oversubscription condition or power supply mismatch in a power domain. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts.
1.3.6.1.4.1.2.3.51.2.4.2.3.14INTEGER {disabled(0), enabled(1)}read-onlydeprecated
systemRemoteLogin
OBJECT-TYPE
Generate an alert if the system detects a new user logged in from a remote site. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.15INTEGER {disabled(0), enabled(1)}read-writemandatory
systemBlade
OBJECT-TYPE
Generate an alert for any informational condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.16INTEGER {disabled(0), enabled(1)}read-writemandatory
systemIO
OBJECT-TYPE
Generate an alert for any informational condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.17INTEGER {disabled(0), enabled(1)}read-writemandatory
systemStorage
OBJECT-TYPE
Generate an alert for any informational condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.18INTEGER {disabled(0), enabled(1)}read-writemandatory
systemPower
OBJECT-TYPE
Generate an alert for any informational condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.19INTEGER {disabled(0), enabled(1)}read-writemandatory
systemChassis
OBJECT-TYPE
Generate an alert for any informational condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.20INTEGER {disabled(0), enabled(1)}read-writemandatory
systemFan
OBJECT-TYPE
Generate an alert for any informational condition on cooling device. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.21INTEGER {disabled(0), enabled(1)}read-writemandatory
systemPWRDO
OBJECT-TYPE
Generate an alert for any informational condition on power on and power off. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration.
1.3.6.1.4.1.2.3.51.2.4.2.3.22INTEGER {disabled(0), enabled(1)}read-writemandatory
alertMode
OBJECT-TYPE
Selects which alert categories will be displayed on the web interface, which alert category objects are accessible through SNMP, and which SNMP trap type an alert is associated with. The enhanced option provides a component based category category scheme and is the only one that is now supported. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. Therefore, this setting should have a value of enhanced(1).
1.3.6.1.4.1.2.3.51.2.4.2.4INTEGER {legacy(0), enhanced(1)}read-writemandatory
securitySettings
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.3
dataEncryption
OBJECT-TYPE
If enabled, all confidential data will be encrypted. The default value is disabled. NOTE: Once the data is encrypted, the only way to reverse this process is to reset to default values.
1.3.6.1.4.1.2.3.51.2.4.3.1INTEGER {disabled(0), enabled(1)}read-writemandatory
trespassWarning
OBJECT-TYPE
If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces.
1.3.6.1.4.1.2.3.51.2.4.3.2INTEGER {disabled(0), enabled(1)}read-writemandatory
trespassWarningDefault
OBJECT-TYPE
Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.3.3INTEGER {execute(1)}read-writemandatory
trespassMessage
OBJECT-TYPE
The value of the trespass warning message.
1.3.6.1.4.1.2.3.51.2.4.3.4OCTET STRING (SIZE(0..1600))read-writemandatory
spClock
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.4
spClockDateAndTimeSetting
OBJECT-TYPE
MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59
1.3.6.1.4.1.2.3.51.2.4.4.1OCTET STRINGread-writemandatory
spClockTimezoneSetting
OBJECT-TYPE
MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is not observed in time zones where the 'Observe DST' value does not contain 'yes' in the table. Also, note that in some cases additional information is required to determine the clock adjustment when DST is observed. The additional information is required when the GMT offset being written is +2:00 or +10:00. Examples -to set the GMT offset to +3:30, set the value to:'+3:30,no' -for Eastern Standard Time and observing DST, set the value to:'-5:00,yes' -for Egypt and observing DST, set the value to:'+2:00,yes,6' GMT Observe Additional Offset DST? DST value ______ _______ __________ +0:00 yes|no +1:00 yes|no +2:00 yes|no When 'Observe DST?' value is 'yes': 5 (for E.Europe) 4 (for GTB) 6 (for Egypt) 7 (for FLE) +3:00 yes|no +3:30 yes|no +4:00 no +4:30 no +5:00 yes|no +5:30 no +6:00 no +7:00 no +8:00 yes|no +9:00 yes|no +9:30 yes|no When 'Observe DST?' value is 'yes': 10 (for South AUS) 9 (for other locations) +10:00 yes|no When 'Observe DST?' value is 'yes': 9 (for AUS Eastern) 10 (for TAS,ACT,NSW,VIC) 4 (for Vladivostok) +11:00 no +12:00 yes|no -12:00 no -11:00 no -10:00 no -9:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -8:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -7:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -6:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -5:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -4:00 yes|no When 'Observe DST' value is 'yes': 12 (for Canada) 1 (for other locations) -3:30 yes|no -3:00 yes|no -2:00 yes|no -1:00 yes|no
1.3.6.1.4.1.2.3.51.2.4.4.2OCTET STRINGread-writemandatory
spIdentification
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.5
spTxtId
OBJECT-TYPE
MM text ID. NOTE: Do not put any 'space characters' at end of the ID.
1.3.6.1.4.1.2.3.51.2.4.5.1OCTET STRING (SIZE(0..16))read-writemandatory
networkConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9
networkInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1
extEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.1
extEthernetInterfaceType
OBJECT-TYPE
The type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.1OCTET STRING (SIZE(0..16))read-onlymandatory
extEthernetInterfaceHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.3OCTET STRING (SIZE(0..64))read-writemandatory
extEthernetInterfaceIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.4IpAddressread-writemandatory
extEthernetInterfaceDataRate
OBJECT-TYPE
Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.5INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6)}read-writemandatory
extEthernetInterfaceDuplexSetting
OBJECT-TYPE
Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.6INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)}read-writemandatory
extEthernetInterfaceLAA
OBJECT-TYPE
Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.7OCTET STRING (SIZE(17))read-writemandatory
extEthernetInterfaceDhcpEnabled
OBJECT-TYPE
Disable or enable DHCP on this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.8INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)}read-writemandatory
extEthernetInterfaceGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.9IpAddressread-writemandatory
extEthernetInterfaceBIA
OBJECT-TYPE
Specifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.10OCTET STRING (SIZE(17))read-onlymandatory
extEthernetInterfaceMTU
OBJECT-TYPE
Contains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.13INTEGERread-writemandatory
extEthernetInterfaceSubnetMask
OBJECT-TYPE
Contains the subnet mask for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.14IpAddressread-writemandatory
dhcpEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16
dhcpHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1OCTET STRING (SIZE(0..64))read-onlymandatory
dhcpIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2IpAddressread-onlymandatory
dhcpGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3IpAddressread-onlymandatory
dhcpSubnetMask
OBJECT-TYPE
Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4IpAddressread-onlymandatory
dhcpDomainName
OBJECT-TYPE
Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5OCTET STRING (SIZE(0..64))read-onlymandatory
dhcpDHCPServer
OBJECT-TYPE
Contains the DHCP server IP address used to acquire the DHCP settings.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6IpAddressread-onlymandatory
dhcpPrimaryDNSServer
OBJECT-TYPE
Contains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7IpAddressread-onlymandatory
dhcpSecondaryDNSServer
OBJECT-TYPE
Contains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8IpAddressread-onlymandatory
dhcpTertiaryDNSServer
OBJECT-TYPE
Contains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9IpAddressread-onlymandatory
intEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.2
intEthernetInterfaceType
OBJECT-TYPE
The type of interface. Indicates 'PPP-1'. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.1OCTET STRING (SIZE(0..16))read-onlydeprecated
intEthernetInterfaceEnabled
OBJECT-TYPE
Disable or enable the internal ethernet interface. NOTE: To alter any of the configuration settings for the ethernet interface, the following procedure should be used: (1) This object should be set to 'interfaceDisabled' (2) Make the modifications to other settings (3) This object should be set to 'interfaceEnabled' (4) Restart the management module Also note that when attempting to enable this interface, the remote IP address is verified to be nonzero. If this verification fails, an error response will be returned and the internal ethernet interface will be left disabled. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.2INTEGER {interfaceDisabled(0), interfaceEnabled(1)}read-writedeprecated
intEthernetInterfaceLocalIPAddress
OBJECT-TYPE
Contains the IP address for the MM side of the internal ethernet link. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.4IpAddressread-writedeprecated
intEthernetInterfaceDataRate
OBJECT-TYPE
Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, or Auto. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.5INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5)}read-onlydeprecated
intEthernetInterfaceDuplexSetting
OBJECT-TYPE
Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.6INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)}read-onlydeprecated
intEthernetInterfaceLAA
OBJECT-TYPE
Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.7OCTET STRING (SIZE(17))read-writedeprecated
intEthernetInterfaceGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.9IpAddressread-writedeprecated
intEthernetInterfaceBIA
OBJECT-TYPE
Specifies the burned-in MAC (BIA) address. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.10OCTET STRING (SIZE(17))read-onlydeprecated
intEthernetInterfaceMTU
OBJECT-TYPE
Contains the Maximum Transmission Unit (MTU) for the ethernet interface NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.13INTEGERread-onlydeprecated
intEthernetInterfaceSubnetMask
OBJECT-TYPE
Contains the subnet mask for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.14IpAddressread-writedeprecated
standbyExtEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.3
standbyExtEthernetInterfaceType
OBJECT-TYPE
The type of interface. Indicates 'Ethernet-1'. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.1OCTET STRING (SIZE(0..16))read-onlymandatory
standbyExtEthernetInterfaceHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.3OCTET STRING (SIZE(0..64))read-writemandatory
standbyExtEthernetInterfaceIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.4IpAddressread-writemandatory
standbyExtEthernetInterfaceDataRate
OBJECT-TYPE
Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.5INTEGER {enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6)}read-writemandatory
standbyExtEthernetInterfaceDuplexSetting
OBJECT-TYPE
Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.6INTEGER {fullDuplex(1), halfDuplex(2), autoDuplex(3)}read-writemandatory
standbyExtEthernetInterfaceLAA
OBJECT-TYPE
Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.7OCTET STRING (SIZE(17))read-writemandatory
standbyExtEthernetInterfaceDhcpEnabled
OBJECT-TYPE
Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.8INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2)}read-writemandatory
standbyExtEthernetInterfaceGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.9IpAddressread-writemandatory
standbyExtEthernetInterfaceBIA
OBJECT-TYPE
Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.10OCTET STRING (SIZE(17))read-onlymandatory
standbyExtEthernetInterfaceMTU
OBJECT-TYPE
Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.13INTEGERread-writemandatory
standbyExtEthernetInterfaceSubnetMask
OBJECT-TYPE
Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.14IpAddressread-writemandatory
advancedFailover
OBJECT-TYPE
User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, no swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.15INTEGER {off(0), ipnoswap(1), ipswap(2)}read-writemandatory
standbyDhcpEthernetInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16
standbyDhcpHostName
OBJECT-TYPE
Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1OCTET STRING (SIZE(0..64))read-onlymandatory
standbyDhcpIPAddress
OBJECT-TYPE
Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2IpAddressread-onlymandatory
standbyDhcpGatewayIPAddress
OBJECT-TYPE
Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3IpAddressread-onlymandatory
standbyDhcpSubnetMask
OBJECT-TYPE
Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4IpAddressread-onlymandatory
standbyDhcpDomainName
OBJECT-TYPE
Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5OCTET STRING (SIZE(0..64))read-onlymandatory
standbyDhcpDHCPServer
OBJECT-TYPE
Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6IpAddressread-onlymandatory
standbyDhcpPrimaryDNSServer
OBJECT-TYPE
Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7IpAddressread-onlymandatory
standbyDhcpSecondaryDNSServer
OBJECT-TYPE
Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8IpAddressread-onlymandatory
standbyDhcpTertiaryDNSServer
OBJECT-TYPE
Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9IpAddressread-onlymandatory
extEthernetInterfaceIPv6
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4
extEthernetInterfaceIPv6Type
OBJECT-TYPE
The type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.1OCTET STRING (SIZE(0..16))read-onlymandatory
extEthernetInterfaceIPv6Enabled
OBJECT-TYPE
The current IPv6 enabled or disabled state of this AMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.2INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5
extEthernetInterfaceIPv6LocalAddress
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1
extEthernetInterfaceIPv6LinkLocalAddress
OBJECT-TYPE
The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1InetAddressIPv6read-onlymandatory
extEthernetInterfaceIPv6StaticIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2
extEthernetInterfaceIPv6StaticIPConfigEnabled
OBJECT-TYPE
The IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceIPv6StaticIPAddress
OBJECT-TYPE
The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2InetAddressIPv6read-writemandatory
extEthernetInterfaceIPv6StaticIPAddressPrefixLen
OBJECT-TYPE
The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3INTEGER (1..128)read-writemandatory
extEthernetInterfaceIPv6StaticIPDefaultRoute
OBJECT-TYPE
The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4InetAddressIPv6read-writemandatory
extEthernetInterfaceIPv6AutoIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3
extEthernetInterfaceIPv6AutoIPConfigEnabled
OBJECT-TYPE
The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceDHCPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2
extEthernetInterfaceDHCPv6Enabled
OBJECT-TYPE
The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceDHCPv6IPAddress
OBJECT-TYPE
The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6DomainName
OBJECT-TYPE
The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4OCTET STRING (SIZE(0..64))read-onlymandatory
extEthernetInterfaceDHCPv6PrimaryDNSServer
OBJECT-TYPE
The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6SecondaryDNSServer
OBJECT-TYPE
The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6TertiaryDNSServer
OBJECT-TYPE
The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7InetAddressIPv6read-onlymandatory
extEthernetInterfaceDHCPv6Server
OBJECT-TYPE
The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8InetAddressIPv6read-onlymandatory
extEthernetInterfaceIPv6StatelessAutoConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3
extEthernetInterfaceIPv6StatelessAutoConfigEnabled
OBJECT-TYPE
The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1INTEGER {disabled(0), enabled(1)}read-writemandatory
extEthernetInterfaceStatelessAutoConfigAddressesTable
OBJECT-TYPE
Table of stateless Auto-Config addresses entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2not-accessiblemandatory
extEthernetInterfaceStatelessAutoConfigAddressesEntry
OBJECT-TYPE
Stateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1not-accessiblemandatory
extEthernetInterfaceStatelessAutoConfigAddressesIndex
OBJECT-TYPE
Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1INTEGERread-onlymandatory
extEthernetInterfaceStatelessAutoConfigAddresses
OBJECT-TYPE
The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2InetAddressIPv6read-onlymandatory
extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen
OBJECT-TYPE
The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3INTEGER (1..128)read-onlymandatory
standbyExtEthernetInterfaceIPv6
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5
standbyEthernetInterfaceIPv6LocalAddress
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1
standbyEthernetInterfaceIPv6LinkLocalAddress
OBJECT-TYPE
The IPv6 link local IP address for the standby AMM.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2
standbyEthernetInterfaceIPv6StaticIPConfigEnabled
OBJECT-TYPE
The IPv6 static IP address state for the AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1INTEGER {disabled(0), enabled(1)}read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPAddress
OBJECT-TYPE
The IPv6 static IP address for the standby AMM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2InetAddressIPv6read-writemandatory
standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen
OBJECT-TYPE
The IPv6 static IP address prefix length for the standyby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3INTEGER (1..128)read-onlymandatory
standbyEthernetInterfaceIPv6StaticIPDefaultRoute
OBJECT-TYPE
The IPv6 static IP address default route for the standby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceDHCPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3
standbyEthernetInterfaceDHCPv6Enabled
OBJECT-TYPE
The DHCPv6 enabled or disabled state for the standby AMM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1INTEGER {disabled(0), enabled(1)}read-onlymandatory
standbyEthernetInterfaceDHCPv6IPAddress
OBJECT-TYPE
The IPv6 address for the standby AMM assigned by DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceDHCPv6DomainName
OBJECT-TYPE
The 64 byte Domain Name for the standby AMM assigned by the DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4OCTET STRING (SIZE(0..64))read-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesTable
OBJECT-TYPE
Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4not-accessiblemandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesEntry
OBJECT-TYPE
Stateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1not-accessiblemandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesIndex
OBJECT-TYPE
Index for stateless Auto-Config addresses.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1INTEGERread-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddresses
OBJECT-TYPE
The stateless Auto-Configuration IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2InetAddressIPv6read-onlymandatory
standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen
OBJECT-TYPE
The stateless Auto-Configration address prefix length.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3INTEGER (1..128)read-onlymandatory
ddnsStatus
OBJECT-TYPE
Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration.
1.3.6.1.4.1.2.3.51.2.4.9.1.10INTEGER {disabled(0), enabled(1)}read-writemandatory
hostName
OBJECT-TYPE
Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName
1.3.6.1.4.1.2.3.51.2.4.9.1.11OCTET STRING (SIZE(0..64))read-writemandatory
standbyHostName
OBJECT-TYPE
Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.12OCTET STRING (SIZE(0..64))read-writemandatory
domainName
OBJECT-TYPE
The user assigned DNS domain name.
1.3.6.1.4.1.2.3.51.2.4.9.1.13OCTET STRINGread-writemandatory
standbyDomainName
OBJECT-TYPE
The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.14OCTET STRINGread-writemandatory
vlanConfigure
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.1.20
vlanGlobalState
OBJECT-TYPE
This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the table, vlanTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.1INTEGER {disable(0), enable(1)}read-writemandatory
vlanCommitTimeout
OBJECT-TYPE
This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.2INTEGER (1..255)read-writemandatory
vlanCommitState
OBJECT-TYPE
This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.3INTEGER {noChangesPending(1), commitNeeded(2), executeCommit(3)}read-writemandatory
vlanTable
OBJECT-TYPE
This table contains the VLAN configuration objects. The default entry has an vlanEntryIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanEntryStatus, at vlanEntryIndex=2 to the value of createRequest(2) and also setting the object, vlanEntryVlanId, at vlanEntryIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20not-accessiblemandatory
vlanEntry
OBJECT-TYPE
VLAN entries.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1not-accessiblemandatory
vlanEntryIndex
OBJECT-TYPE
Index for VLAN entry. If vlanEntryIndex is equal to 1, it is the Default VLAN entry and cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1INTEGER (1..2)read-onlymandatory
vlanEntryVlanId
OBJECT-TYPE
Valid VLAN ID. Allowed values are 1..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanEntryIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanEntryState set to enable(1) or restart(2) for this change to take effect.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2INTEGER (1..4094)read-writemandatory
vlanEntryName
OBJECT-TYPE
This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3OCTET STRING (SIZE(0..31))read-writemandatory
vlanEntryStatus
OBJECT-TYPE
This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanEntryStatus = createRequest 2. Set vlanEntryVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4EntryStatusread-writemandatory
vlanEntryState
OBJECT-TYPE
This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5INTEGER {disable(0), enable(1), restart(2)}read-writemandatory
vlanEntrySOLAccess
OBJECT-TYPE
This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6INTEGER {disable(0), enable(1)}read-writemandatory
vlanEntrycKVMAccess
OBJECT-TYPE
This object allows the user to set whether the VLAN for this entry will have access to the installed cards for concurrent keyboard, video, and mouse (cKVM). Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.7INTEGER {disable(0), enable(1)}read-writemandatory
vlanEntryTagging
OBJECT-TYPE
This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanEntryIndex value of 1. By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8INTEGER {disable(0), enable(1)}read-writemandatory
vlanEntryIOModuleAccess
OBJECT-TYPE
This read-only object indicates whether the VLAN for this entry will have access to the IO Modules. Only the VLAN entry with the vlanEntryIndex value of 1 will report this object with the value of enable(1), all other entries will have a value of disable(0).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.9INTEGER {disable(0), enable(1)}read-onlymandatory
vlanEntryVlanDefault
OBJECT-TYPE
This object specifies which vlanTable entry is the 'default entry'. By default, the entry with the vlanEntryIndex value of 1 will have this object set to true(1). Only one vlanTable entry can be designated as the VLAN default entry. Setting this object to true(1) for an entry will make this object false(0) for all other vlanTable entries. Only the vlanTable entry with this object set to true(1) will allow the vlanEntryTagging object to be configurable for this vlanEntryIndex index.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.10INTEGER {false(0), true(1)}read-writemandatory
vlanEntryIPv4StaticAddress
OBJECT-TYPE
This object sets the IP address for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31IpAddressread-writemandatory
vlanEntryIPv4StaticGateway
OBJECT-TYPE
This object sets the IP address for the IP gateway for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32IpAddressread-writemandatory
vlanEntryIPv4StaticMask
OBJECT-TYPE
This object sets the subnet mask for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33IpAddressread-writemandatory
vlanEntryIPv4SubnetRoute1
OBJECT-TYPE
This object sets the IP address of the subnet route 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51IpAddressread-writemandatory
vlanEntryIPv4SubnetRouteMask1
OBJECT-TYPE
This object sets the subnet route mask 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52IpAddressread-writemandatory
vlanEntryIPv4SubnetRoute2
OBJECT-TYPE
This object sets the IP address of the subnet route 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53IpAddressread-writemandatory
vlanEntryIPv4SubnetRouteMask2
OBJECT-TYPE
This object sets the subnet route mask 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54IpAddressread-writemandatory
vlanEntryIPv4SubnetRoute3
OBJECT-TYPE
This object sets the IP address of the subnet route 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55IpAddressread-writemandatory
vlanEntryIPv4SubnetRouteMask3
OBJECT-TYPE
This object sets the subnet route mask 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1).
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56IpAddressread-writemandatory
tcpProtocols
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3
snmpAgentConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1
snmpSystemContact
OBJECT-TYPE
A NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.1OCTET STRING (SIZE(0..48))read-writemandatory
snmpSystemLocation
OBJECT-TYPE
A NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.2OCTET STRING (SIZE(0..48))read-writemandatory
snmpSystemAgentTrapsDisable
OBJECT-TYPE
Disable or enable SNMP traps.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.3INTEGER {trapsEnabled(0), trapsDisabled(1)}read-writemandatory
snmpAgentCommunityConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4
snmpCommunityTable
OBJECT-TYPE
Table of SNMP Community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1not-accessiblemandatory
snmpCommunityEntry
OBJECT-TYPE
SNMP community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1not-accessiblemandatory
snmpCommunityEntryIndex
OBJECT-TYPE
Index for SNMP Agent Community entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1INTEGER (0..255)read-onlymandatory
snmpCommunityEntryCommunityName
OBJECT-TYPE
SNMP Community entry name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2OCTET STRING (SIZE(0..15))read-writemandatory
snmpCommunityEntryCommunityIpAddress1
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress2
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress3
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityViewType
OBJECT-TYPE
Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6INTEGER {read-Traps(1), write-Read-Traps(2), traps-Only(3)}read-writemandatory
snmpCommunityEntryCommunityIpAddress4
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.7OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress5
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.8OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress6
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.9OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress7
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.10OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress8
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.11OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress9
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.12OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress10
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.13OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress11
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.14OCTET STRING (SIZE(0..63))read-writemandatory
snmpCommunityEntryCommunityIpAddress12
OBJECT-TYPE
SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.15OCTET STRING (SIZE(0..63))read-writemandatory
snmpv1SystemAgentEnable
OBJECT-TYPE
Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.5INTEGER {disabled(0), enabled(1)}read-writemandatory
snmpv3SystemAgentEnable
OBJECT-TYPE
Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
snmpAgentUserProfileConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9
snmpUserProfileTable
OBJECT-TYPE
Table of SNMPv3 User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1not-accessiblemandatory
snmpUserProfileEntry
OBJECT-TYPE
SNMP User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1not-accessiblemandatory
snmpUserProfileEntryIndex
OBJECT-TYPE
Index for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1INTEGER (0..255)read-onlymandatory
snmpUserProfileEntryContextName
OBJECT-TYPE
SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3OCTET STRING (SIZE(0..31))read-writemandatory
snmpUserProfileEntryAuthProt
OBJECT-TYPE
SNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4INTEGER {none(1), md5(2), sha(3)}read-writemandatory
snmpUserProfileEntryPrivProt
OBJECT-TYPE
SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6INTEGER {none(1), des(2), aes(4)}read-writemandatory
snmpUserProfileEntryPrivPassword
OBJECT-TYPE
SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7OCTET STRING (SIZE(0..31))read-writemandatory
snmpUserProfileEntryViewType
OBJECT-TYPE
SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8INTEGER {read-Traps(1), read-Write-Traps(2), traps-Only(3)}read-writemandatory
snmpUserProfileEntryIpAddress
OBJECT-TYPE
SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9OCTET STRING (SIZE(0..63))read-writemandatory
dnsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.2
dnsEnabled
OBJECT-TYPE
Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' (4) Restart the management module Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.1INTEGER {dnsDisabled(0), dnsEnabled(1)}read-writemandatory
dnsServerIPAddress1
OBJECT-TYPE
Contains the primary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.2IpAddressread-writemandatory
dnsServerIPAddress2
OBJECT-TYPE
Contains the secondary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.3IpAddressread-writemandatory
dnsServerIPAddress3
OBJECT-TYPE
Contains the tertiary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.4IpAddressread-writemandatory
dnsServerIPv6Address1
OBJECT-TYPE
Contains the primary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.12InetAddressIPv6read-writemandatory
dnsServerIPv6Address2
OBJECT-TYPE
Contains the secondary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.13InetAddressIPv6read-writemandatory
dnsServerIPv6Address3
OBJECT-TYPE
Contains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.14InetAddressIPv6read-writemandatory
dnsPriority
OBJECT-TYPE
Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.20INTEGER {ipv6(1), ipv4(2)}read-writemandatory
smtpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.3
smtpServerNameOrIPAddress
OBJECT-TYPE
A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.3.1OCTET STRING (SIZE(0..64))read-writemandatory
attachmentsToEmailAlerts
OBJECT-TYPE
Indicates if the service information should be attached to an email alert.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.2INTEGER {noAttachments(0), attachServiceInformation(1)}read-writemandatory
smtpEmailDomain
OBJECT-TYPE
A NULL terminated string that contains the SMTP email domain. If this field is empty, the AMM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.3OCTET STRING (SIZE(0..64))read-writemandatory
tcpApplicationConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.4
telnetInactivityTimeout
OBJECT-TYPE
Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.1INTEGERread-writemandatory
commandModeInactivityTimeout
OBJECT-TYPE
The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.2INTEGERread-writemandatory
secureCommandModeEnable
OBJECT-TYPE
Set Secure TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. NOTE: System Management Software requires this to be enabled for secure communication to the AMM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.3INTEGERread-writemandatory
commandModeEnable
OBJECT-TYPE
Set TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. NOTE: System Management Software requires this to be enabled for non-secure communication to the AMM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.4INTEGERread-writemandatory
slpAddrType
OBJECT-TYPE
Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.5INTEGER {multicast(0), broadcast(1)}read-writemandatory
slpMulticastAddr
OBJECT-TYPE
Service Locator Protocol Multicast address
1.3.6.1.4.1.2.3.51.2.4.9.3.4.6IpAddressread-writemandatory
slpEnable
OBJECT-TYPE
Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.7INTEGER {disabled(0), enabled(1)}read-writemandatory
telnetEnable
OBJECT-TYPE
Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.9INTEGER {disabled(0), enabled(1)}read-writemandatory
sshEnable
OBJECT-TYPE
Disable/Enable SSH.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.10INTEGER {disabled(0), enabled(1)}read-writemandatory
sshVersion
OBJECT-TYPE
When SSH is enabled, this object allows the user to configure whether the SSH server accepts all versions of client connections or whether it restricts the connectivity to the more secure version 2 only. NOTE: Only SSH version 2 is supported now.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.11INTEGER {allVersions(0), version2Only(1)}read-writemandatory
sslServerEnable
OBJECT-TYPE
Disable/Enable SSL Server.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.15INTEGER {disabled(0), enabled(1)}read-writemandatory
sslClientEnable
OBJECT-TYPE
Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.16INTEGER {disabled(0), enabled(1)}read-writemandatory
ftpEnable
OBJECT-TYPE
Disable/Enable FTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.17INTEGER {disabled(0), enabled(1)}read-writemandatory
tftpEnable
OBJECT-TYPE
Disable/Enable TFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.19INTEGER {disabled(0), enabled(1)}read-writemandatory
smashTelnetEnable
OBJECT-TYPE
Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over Telnet. This option is not available on all systems.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.20INTEGER {disabled(0), enabled(1)}read-writemandatory
smashSshEnable
OBJECT-TYPE
Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. A valid SSH server key must be installed before enabling secure SMASH. This option is not available on all systems.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.21INTEGER {disabled(0), enabled(1)}read-writemandatory
tftpCreateEmptyFile
OBJECT-TYPE
This MIB object is no longer a requirement for TFTP and has been deprecated.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.22OCTET STRINGread-writedeprecated
ftpTimeout
OBJECT-TYPE
The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.23INTEGERread-writemandatory
rdEnable
OBJECT-TYPE
Disable/Enable Remote Disk. NOTE: Change to Remote Disk will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.24INTEGER {disabled(0), enabled(1)}read-writemandatory
rdocEnable
OBJECT-TYPE
Disable/Enable Remote Disk on Card. NOTE: Change to Remote Disk on Card will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.25INTEGER {disabled(0), enabled(1)}read-writemandatory
kvmEnable
OBJECT-TYPE
Disable/Enable KVM. NOTE: Change to KVM will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.26INTEGER {disabled(0), enabled(1)}read-writemandatory
mmSshServerConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27
mmSshServerHostKeyTable
OBJECT-TYPE
A table that contains per public/private host key pair information.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1not-accessiblemandatory
mmSshServerHostKeyEntry
OBJECT-TYPE
A list of information about a particular public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1not-accessiblemandatory
mmSshServerHostKeyIndex
OBJECT-TYPE
The index of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1INTEGERread-onlymandatory
mmSshServerHostKeyType
OBJECT-TYPE
The type of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2INTEGER {sshDss(1), sshRsa(2)}read-onlymandatory
mmSshServerHostKeySize
OBJECT-TYPE
The size of the public/private host key pair. NOTE: The AMM supports only the bits2048 value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3INTEGER {bits512(1), bits768(2), bits1024(3), bits2048(4), bits4096(5)}read-onlymandatory
mmSshServerHostKeyFingerprint
OBJECT-TYPE
The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the AMM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4OCTET STRINGread-onlymandatory
mmSshServerHostKeyGenerate
OBJECT-TYPE
Initiate the new Host Keys generation process for the AMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2INTEGER {execute(1)}read-writemandatory
mmSshServerHostKeyGenerateProgress
OBJECT-TYPE
Indicate the progress of the key generation process.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3OCTET STRINGread-onlymandatory
rpEnable
OBJECT-TYPE
Disable/Enable Remote Presence.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.28INTEGER {disabled(0), enabled(1)}read-writemandatory
tcpPortAssignmentCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.5
tcpPortsRestoreDefault
OBJECT-TYPE
Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 Remote Disk: 1044 Remote Disk-on-Card: 1045 Remote KVM: 3900 FTP: 21 FTP Data: 20 TFTP: 69 SMASH telnet: 50023 SMASH ssh: 50022 SLP: 427 Storage Description Service: 1046 NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.1INTEGER {execute(1)}read-writemandatory
httpPortAssignment
OBJECT-TYPE
HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.2INTEGERread-writemandatory
httpsPortAssignment
OBJECT-TYPE
SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.3INTEGERread-writemandatory
telnetPortAssignment
OBJECT-TYPE
Telnet port number. Default value is 23. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.4INTEGERread-writemandatory
sshPortAssignment
OBJECT-TYPE
SSH port number. Default value is 22.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.5INTEGERread-writemandatory
snmpAgentPortAssignment
OBJECT-TYPE
SNMP Agent port number. Default value is 161. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.6INTEGERread-writemandatory
snmpTrapsPortAssignment
OBJECT-TYPE
SNMP Traps port number. Default value is 162. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.7INTEGERread-writemandatory
commandModePortAssignment
OBJECT-TYPE
TCP Command Mode port number. Default value is 6090. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.8INTEGERread-writemandatory
secureCommandModePortAssignment
OBJECT-TYPE
Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.9INTEGERread-writemandatory
rdPortAssignment
OBJECT-TYPE
Remote Disk port number. Default value is 1044. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.10INTEGERread-writedeprecated
rdocPortAssignment
OBJECT-TYPE
Remote Disk-on-Card port number. Default value is 1045. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.11INTEGERread-writedeprecated
kvmPortAssignment
OBJECT-TYPE
Remote KVM port number. Default value is 3900. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.12INTEGERread-writedeprecated
ftpPortAssignment
OBJECT-TYPE
FTP port number. Default value is 21. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.13INTEGERread-writemandatory
ftpDataPortAssignment
OBJECT-TYPE
FTP Data port number. Default value is 20. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.14INTEGERread-writemandatory
tftpPortAssignment
OBJECT-TYPE
TFTP port number. Default value is 69.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.15INTEGERread-writemandatory
smashTelnetPortAssignment
OBJECT-TYPE
The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over telnet. Default value is 50023. Change will take effect immediately. This option is not available on all systems.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.17INTEGERread-writemandatory
smashSshPortAssignment
OBJECT-TYPE
The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. Default value is 50022. This option is not available on all systems.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.18INTEGERread-writemandatory
slpPortAssignment
OBJECT-TYPE
Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.19INTEGERread-writemandatory
sdsPortAssignment
OBJECT-TYPE
Storage description service port number. Default value is 1046. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.20INTEGERread-writedeprecated
rpPortAssignment
OBJECT-TYPE
Remote Presence port. Default value is 3900. This port cannot be disabled since it is the single service entry point for all the services provided by AMM RPServ to clients.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.21INTEGERread-writemandatory
ldapClientCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.6
ldapServer1NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.1OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer1PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.2INTEGERread-writemandatory
ldapServer2NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.3OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer2PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.4INTEGERread-writemandatory
ldapServer3NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.5OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer3PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.6INTEGERread-writemandatory
ldapRootDN
OBJECT-TYPE
A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.7OCTET STRING (SIZE(0..256))read-writemandatory
ldapUserSearchBaseDN
OBJECT-TYPE
As part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search request must specify the base DN for the actual search. This field specifies the base DN which should be used to search the User directory. This is a NULL terminated 255 byte string. An example might look like cn=users,dn=foobar,dn=com. If this field is left blank, the Root DN will be used as the search base instead. As mentioned, user searches are part of the authentication process. They are carried out to retrieve information about the user such as login permissions, callback number, and group memberships. For Version 2.0 LDAP clients, it is strongly encouraged that this parameter be configured, otherwise a search using the root DN may not succeed (as seen on Active Directory servers). NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.8OCTET STRING (SIZE(0..255))read-writedeprecated
ldapGroupFilter
OBJECT-TYPE
This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.9OCTET STRING (SIZE(0..511))read-writemandatory
ldapBindingMethod
OBJECT-TYPE
On initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. Strict UPN: This is the same as UPN above, except that the userid must have the form someuser@somedomain. The string entered by the user will be parsed for the @ symbol. NOTE: strictUserPrincipalName(3) option is available on MM only.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.10INTEGER {anonymousAuthentication(0), clientAuthentication(1), userPrincipalName(2), strictUserPrincipalName(3)}read-writemandatory
ldapClientAuthenticationDN
OBJECT-TYPE
The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. The client DN is a NULL terminated 255 byte string. These parameters are configured here. Note that the password can be left blank.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.11OCTET STRING (SIZE(0..255))read-writemandatory
ldapClientAuthenticationPassword
OBJECT-TYPE
The client authentication password
1.3.6.1.4.1.2.3.51.2.4.9.3.6.12OCTET STRING (SIZE(0..16))read-writemandatory
ldapUIDsearchAttribute
OBJECT-TYPE
When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.13OCTET STRING (SIZE(0..64))read-writemandatory
ldapGroupSearchAttribute
OBJECT-TYPE
When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.14OCTET STRING (SIZE(0..64))read-writemandatory
ldapLoginPermissionAttribute
OBJECT-TYPE
When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.15OCTET STRING (SIZE(0..64))read-writemandatory
ldapUseDNSOrPreConfiguredServers
OBJECT-TYPE
The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.16INTEGER {usePreConfiguredLDAPServers(0), useDNSToFindLDAPServers(1)}read-writemandatory
ldapDomainSource
OBJECT-TYPE
The DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is joesmith@mycompany.com, the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.17INTEGER {extractSearchDomainFromLoginID(0), useOnlyConfiguredSearchDomainBelow(1), tryLoginFirstThenConfiguredValue(2)}read-writedeprecated
ldapSearchDomain
OBJECT-TYPE
This parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.18OCTET STRING (SIZE(0..64))read-writedeprecated
ldapServiceName
OBJECT-TYPE
The DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.19OCTET STRING (SIZE(0..16))read-writedeprecated
ldapRBSModelCfg
OBJECT-TYPE
There are two mechanisms to authenticate and authorize users on the AMM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and AMMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. AMM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.20INTEGER {oldPermissionString(0), newRBSModel(1)}read-writemandatory
ldapTargetName
OBJECT-TYPE
When administrator chooses Enhanced Role Based Security authentication model, he can associate one AMM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The AMM target name can be looked as alias of AMM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character)
1.3.6.1.4.1.2.3.51.2.4.9.3.6.21OCTET STRING (SIZE(0..16))read-writemandatory
ldapAuthCfg
OBJECT-TYPE
If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.22INTEGER {authenticationAndAuthorization(0), authenticationOnly(1)}read-writemandatory
ldapForestName
OBJECT-TYPE
LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.23OCTET STRING (SIZE(0..64))read-writemandatory
ldapDomainName
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP Domain Name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.24OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer4NameOrIPAddress
OBJECT-TYPE
A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.25OCTET STRING (SIZE(0..256))read-writemandatory
ldapServer4PortNumber
OBJECT-TYPE
LDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.26INTEGERread-writemandatory
uplinkCheckConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.7
uplinkCheckEnabled
OBJECT-TYPE
Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.1INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)}read-writemandatory
uplinkCheckDelay
OBJECT-TYPE
Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.2INTEGERread-writemandatory
logicalUplinkDestination
OBJECT-TYPE
Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.3IpAddressread-writemandatory
logicalUplinkCheckEnabled
OBJECT-TYPE
Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.4INTEGER {uplinkCheckDisabled(0), uplinkCheckEnabled(1)}read-writemandatory
logicalUplinkCheckDelay
OBJECT-TYPE
Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.5INTEGERread-writemandatory
physicalUplinkCheckDelayInSecs
OBJECT-TYPE
Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.6INTEGERread-writemandatory
logicalUplinkCheckDelayInSecs
OBJECT-TYPE
Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.7INTEGERread-writemandatory
logicalUplinkIPv6Destination
OBJECT-TYPE
Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: This MIB object is only applicable if IPv6 is enabled on the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.8InetAddressIPv6read-writemandatory
logicalUplinkFailoverPolicy
OBJECT-TYPE
Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.9INTEGER {either(1), both(2)}read-writemandatory
ntpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.8
ntpEnable
OBJECT-TYPE
Disable/Enable the NTP client. The client will update the AMM system clock at the frequency specified.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.1INTEGER {disabled(0), enabled(1)}read-writemandatory
ntpIpAddressHostname
OBJECT-TYPE
NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.2OCTET STRING (SIZE(0..63))read-writemandatory
ntpUpdateFrequency
OBJECT-TYPE
The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the AMM clock can only be synchronized with the NTP server manually.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.3INTEGERread-writemandatory
ntpLastUpdate
OBJECT-TYPE
The date and time that the NTP server last updated the system clock.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.4OCTET STRINGread-onlymandatory
ntpUpdateClock
OBJECT-TYPE
Update the AMM system clock with the specified NTP server. A valid NTP server must be configured first.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.5INTEGER {execute(1)}read-writemandatory
ntpAuthEntry
OBJECT-TYPE
The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key index> must be an integer between 1 and 65535. <key type> must be M. <key> is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: <key index> <key type> It does not return the actual key.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.6OCTET STRINGread-writemandatory
ntpAuthEnable
OBJECT-TYPE
Enables/Disables NTP v3 authentication
1.3.6.1.4.1.2.3.51.2.4.9.3.8.7INTEGER {disabled(0), enabled(1)}read-writemandatory
syslogConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.9
syslogSevFilterLevel
OBJECT-TYPE
syslogSevFilterLevel error/warning/information .
1.3.6.1.4.1.2.3.51.2.4.9.3.9.1INTEGER {error(0), warning(1), information(2)}read-writemandatory
syslogCollectorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2
syslogCollectorTable
OBJECT-TYPE
Table of Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1not-accessiblemandatory
syslogCollectorEntry
OBJECT-TYPE
Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1not-accessiblemandatory
syslogCollectorIndex
OBJECT-TYPE
Index for Syslog Collector entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1INTEGER (0..255)read-onlymandatory
syslogCollectorHostnameOrIpAddress
OBJECT-TYPE
Syslog Collector IP address or host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2OCTET STRING (SIZE(0..63))read-writemandatory
syslogCollectorPort
OBJECT-TYPE
Syslog Collector port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3INTEGER (1..65535)read-writemandatory
syslogCollectorEnable
OBJECT-TYPE
Syslog Collector enable/disable.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
syslogTestPacket
OBJECT-TYPE
Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.3INTEGER {execute(1)}read-writemandatory
solConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10
solGlobalConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10.1
solEnable
OBJECT-TYPE
Disable/Enable SOL dynamically.
1.3.6.1.4.1.2.3.51.2.4.10.1.1INTEGER {solDisabled(0), solEnabled(1)}read-writemandatory
solVlanId
OBJECT-TYPE
This is the virtual LAN ID for the internal management network between the MM and the Blade System Management Processors (BSMPs). The range of valid VLAN ID's is 3 to 4095.
1.3.6.1.4.1.2.3.51.2.4.10.1.2INTEGERread-writemandatory
solAccumulateTimeout
OBJECT-TYPE
This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms.
1.3.6.1.4.1.2.3.51.2.4.10.1.3INTEGERread-writemandatory
solCharSendThreshold
OBJECT-TYPE
This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 255
1.3.6.1.4.1.2.3.51.2.4.10.1.4INTEGERread-writemandatory
solRetry
OBJECT-TYPE
Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired.
1.3.6.1.4.1.2.3.51.2.4.10.1.5INTEGERread-writemandatory
solRetryInterval
OBJECT-TYPE
Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back.
1.3.6.1.4.1.2.3.51.2.4.10.1.6INTEGERread-writemandatory
solExitToCliKeySeq
OBJECT-TYPE
This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (.
1.3.6.1.4.1.2.3.51.2.4.10.1.7OCTET STRING (SIZE(0..16))read-writemandatory
solResetBladeKeySeq
OBJECT-TYPE
This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R.
1.3.6.1.4.1.2.3.51.2.4.10.1.8OCTET STRING (SIZE(0..16))read-writemandatory
solBladeConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.10.2
solBladeTable
OBJECT-TYPE
SOL Blade configuration table.
1.3.6.1.4.1.2.3.51.2.4.10.2.1not-accessiblemandatory
solBladeEntry
OBJECT-TYPE
SOL Blade table entry
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1not-accessiblemandatory
solBladeIndex
OBJECT-TYPE
SOL Blade table index.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1INTEGERread-onlymandatory
solBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2OCTET STRINGread-onlymandatory
solBladeEnable
OBJECT-TYPE
Disable or enable a SOL on a blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3INTEGER {solBladeDisabled(0), solBladeEnabled(1)}read-writemandatory
solBladeIpAddr
OBJECT-TYPE
IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4IpAddressread-onlymandatory
solBladeSessionStatus
OBJECT-TYPE
Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5INTEGER {solSessionNotReady(0), solSessionReady(1), solSessionActive(2)}read-onlymandatory
solBladeCapability
OBJECT-TYPE
Display whether or not the blade support SOL feature.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6INTEGER {notSupport(0), support(1)}read-onlymandatory
chassisInternalNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.11
cinsSupported
OBJECT-TYPE
Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported.
1.3.6.1.4.1.2.3.51.2.4.11.1INTEGERread-onlymandatory
cinGlobalEnable
OBJECT-TYPE
Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: AMM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces.
1.3.6.1.4.1.2.3.51.2.4.11.2INTEGER {cinDisabled(0), cinEnabled(1)}read-writemandatory
cinTable
OBJECT-TYPE
Chassis Internal Network (CIN) configuration table.
1.3.6.1.4.1.2.3.51.2.4.11.3not-accessiblemandatory
cinEntry
OBJECT-TYPE
Chassis Internal Network (CIN) table entry.
1.3.6.1.4.1.2.3.51.2.4.11.3.1not-accessiblemandatory
cinIndex
OBJECT-TYPE
Chassis Internal Network (CIN) table index.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.1INTEGERread-onlymandatory
cinDefExists
OBJECT-TYPE
Indicates if a Chassis Internal Network (CIN) definition exists for this index or not.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.2INTEGER {false(0), true(1)}read-onlymandatory
cinDelete
OBJECT-TYPE
Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.3INTEGER {execute(1)}read-writemandatory
cinEnable
OBJECT-TYPE
Disable or enable a Chassis Internal Network (CIN) definition. Enabled: AMM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
cinId
OBJECT-TYPE
This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.5INTEGERread-writemandatory
cinIpAddress
OBJECT-TYPE
Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the AMM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of AMM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address
1.3.6.1.4.1.2.3.51.2.4.11.3.1.6IpAddressread-writemandatory
cinIpv6Address
OBJECT-TYPE
Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.7InetAddressIPv6read-writemandatory
cinStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.11.4
cinStatusTable
OBJECT-TYPE
Table of Chassis Internal Network (CIN) status entry information.
1.3.6.1.4.1.2.3.51.2.4.11.4.1not-accessiblemandatory
cinStatusEntry
OBJECT-TYPE
Chassis Internal Network (CIN) status table entry.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1not-accessiblemandatory
cinStatusIndex
OBJECT-TYPE
The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1INTEGERread-onlymandatory
cinStatusString
OBJECT-TYPE
Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the AMM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2OCTET STRINGread-onlymandatory
cinPortConfigTable
OBJECT-TYPE
Chassis Internal Network (CIN) configuration table for viewing and configuring the protocol port information for a particular CIN entry.
1.3.6.1.4.1.2.3.51.2.4.11.5not-accessiblemandatory
cinPortConfigEntry
OBJECT-TYPE
Chassis Internal Network (CIN) entry for viewing and configuring the protocol port information for a particular CIN entry.
1.3.6.1.4.1.2.3.51.2.4.11.5.1not-accessiblemandatory
cinPortConfigCINIndex
OBJECT-TYPE
The identifier for the particular CIN configuration that these protocol port definitions are associated with. This object is the same as the cinIndex value in the cinTable.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.1INTEGERread-onlymandatory
cinPortConfigIndex
OBJECT-TYPE
The identifier of a particular CIN protocol port configuration for a given CIN configuration as specified by cinPortConfigCINIndex. There can be up to 16 unique protocol port definitions per CIN configuration.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.2INTEGERread-onlymandatory
cinPortConfigProtocolID
OBJECT-TYPE
Indicates whether the port protocol definition is for a TCP or UDP port. If the value of notDefined(3) is returned, the entry has yet to be configured.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.3INTEGER {tcp(1), udp(2), notDefined(3)}read-writemandatory
cinPortConfigExternalPort
OBJECT-TYPE
The external port number specified for this port protocol definition, ranging from 1 to 65,534.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.4INTEGERread-writemandatory
cinPortConfigInternalPort
OBJECT-TYPE
The internal port number specified for this port protocol definition, ranging from 1 to 65,534.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.5INTEGERread-writemandatory
cinPortConfigEnable
OBJECT-TYPE
The status of this port protocol definition.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
cinPortConfigDirection
OBJECT-TYPE
The traffic direction specified for this port protocol definition.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.7INTEGER {incoming(1), outgoing(2)}read-writemandatory
configurationManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.4.15
saveConfigurationToChassis
OBJECT-TYPE
Save the configuration settings from the AMM to the chassis. This operation may take several seconds. The input values for the SET command when AMM is installed in BladeCenter and BladeCenter T are: 1: Save the configuration settings in compressed(AMM) format. 2: Save the configuration settings in legacy(MM) format. This option has been deprecated. other: Invalid. The input values for the SET command when AMM is installed in BladeCenter H and BladeCenter HT are: 1: Save the configuration settings in compressed(AMM) format. other: Invalid. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.4.15.1INTEGER {compressedFormat(1), legacyFormat(2)}read-writemandatory
restoreConfigurationFromChassis
OBJECT-TYPE
Restore the configuration settings to the AMM from the BladeCenter chassis. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.4.15.2INTEGER {execute(1)}read-writemandatory
autoReadConfigInNewChassis
OBJECT-TYPE
The AMM will automatically read configuration settings from the midplane every time the AMM is inserted into a new chassis. NOTE: This MIB object is for AMM only.
1.3.6.1.4.1.2.3.51.2.4.15.3INTEGER {disabled(0), enabled(1)}read-writemandatory
telcoManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5
telcoAlarmReq
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5.1
telcoAlarmSet
OBJECT-TYPE
Create a software alarm. An input octet string consists of the alarm severity level and the alarm description (40 bytes max). The following severity levels are valid : CRT Critical MJR Major MNR Minor NOTE 1: The level (e.g. MJR) and alarm description string must be separated by a blank, otherwise, a badValue error will be returned. NOTE 2: Value returned for the GET command is meaningless for this MIB object. NOTE 3: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.5.1.1OCTET STRINGread-writemandatory
telcoAlarmAck
OBJECT-TYPE
Acknowledge an alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE 1: Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.5.1.2OCTET STRINGread-writemandatory
telcoAlarmClear
OBJECT-TYPE
Clear an active alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE1 : Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.5.1.3OCTET STRINGread-writemandatory
telcoHWManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5.3
tappowerReq
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5.3.1
tappoweronoff
OBJECT-TYPE
Telco Alarm Panel power on or power off. If powering off a currently powered on Telco Alarm Panel, then all LEDs of this request card will be reset to OFF and the Safely Remove LED will be turned ON to indicate the card is safe for removal. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.5.3.1.1INTEGER {poweroff(0), poweron(1)}read-writemandatory
ncReq
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5.3.2
ncReqTable
OBJECT-TYPE
Table of the Network Clock Module Operations. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.5.3.2.1not-accessibledeprecated
ncReqEntry
OBJECT-TYPE
Network Clock Module Power ON/OFF entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1not-accessibledeprecated
ncReqIndex
OBJECT-TYPE
Network Clock Module Request index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.1INTEGER (0..128)read-onlydeprecated
ncReqBayNumber
OBJECT-TYPE
Network Clock Module Request Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.2INTEGER {networkclock1(1), networkclock2(2)}read-onlydeprecated
ncReqPoweronoff
OBJECT-TYPE
Request to power on/off for the specified Network Clock Module. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.3INTEGER {poweroff(0), poweron(1)}read-writedeprecated
telcoOEM
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.5.127
telcoOEMs
OBJECT-TYPE
A bitmap of information about the contents of this subtree. The bitmap is a variable length string containing a list of 1's and 0's. Every bit that is set to 1 has a corresponding subtree entry that is supported in firmware, while a 0 means that the subtree entry is unavailable. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.5.127.1OCTET STRINGread-onlymandatory
restartReset
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.7
restartSPImmediately
OBJECT-TYPE
Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.4INTEGER {execute(1)}read-writemandatory
restartStandbyMM
OBJECT-TYPE
Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.7.5INTEGER {execute(1)}read-writemandatory
switchOverRedundantMM
OBJECT-TYPE
Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM.
1.3.6.1.4.1.2.3.51.2.7.7INTEGER {execute(1)}read-writemandatory
resetSPConfigAndRestart
OBJECT-TYPE
Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.20INTEGER {execute(1)}read-writemandatory
resetSPConfigAndRestartSaveLogs
OBJECT-TYPE
Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.21INTEGER {execute(1)}read-writemandatory
blades
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22
processorBlade
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1
bladeMediaTrayBladeId
OBJECT-TYPE
Allocate the media tray to a blade of a BladeCenter system. On a get command, a blade ID of 0x00 means that no blade is currently using the device. A set command cannot allocate the media tray to the management module. NOTE: A blade cannot be allocated to the media tray if the value of OID remoteMediaTraySwitchEnable of the blade is disabled.
1.3.6.1.4.1.2.3.51.2.22.1.1INTEGER {managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-writemandatory
bladeKVMBladeId
OBJECT-TYPE
Allocate the keyboard, video, and mouse ports (KVM) to a blade of a blade runner system. On a get command, a blade ID of 0x00 means that no blade is currently using the devices. A set command cannot allocate the KVM to the management module.
1.3.6.1.4.1.2.3.51.2.22.1.2INTEGER {managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-writemandatory
bladeBootSequenceTable
OBJECT-TYPE
Table of blade boot sequence information. Contains the boot sequence information for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.3not-accessiblemandatory
bladeBootSequenceEntry
OBJECT-TYPE
Boot sequence entry
1.3.6.1.4.1.2.3.51.2.22.1.3.1not-accessiblemandatory
bootSequenceIndex
OBJECT-TYPE
Blade boot sequence index.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.1INTEGERread-onlymandatory
bootSequenceBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bootSequenceBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.3INTEGER {false(0), true(1)}read-onlymandatory
bootSequenceBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bootSequenceBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)}read-onlymandatory
bootSequenceBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.6OCTET STRINGread-onlymandatory
bootSequence1
OBJECT-TYPE
The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.7INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)}read-writemandatory
bootSequence2
OBJECT-TYPE
The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.8INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)}read-writemandatory
bootSequence3
OBJECT-TYPE
The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.9INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)}read-writemandatory
bootSequence4
OBJECT-TYPE
The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.10INTEGER {noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255)}read-writemandatory
bladeRemoteControl
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.4
bladeRemoteControlTable
OBJECT-TYPE
Table of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1not-accessiblemandatory
bladeRemoteControlEntry
OBJECT-TYPE
Remote power control entry
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1not-accessiblemandatory
remoteControlIndex
OBJECT-TYPE
Blade remote power control index.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1INTEGERread-onlymandatory
remoteControlBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
remoteControlBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
remoteControlBladePowerState
OBJECT-TYPE
The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
remoteControlBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)}read-onlymandatory
remoteControlBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6OCTET STRINGread-onlymandatory
remotePowerControlEnable
OBJECT-TYPE
Blade remote power control enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteMediaTrayControlEnable
OBJECT-TYPE
Blade media tray enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.8INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteKVMControlEnable
OBJECT-TYPE
Blade KVM enablement status. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.9INTEGER {disabled(0), enabled(1)}read-writemandatory
remoteWakeOnLanControlEnable
OBJECT-TYPE
Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
remoteMediaTraySwitchEnable
OBJECT-TYPE
Blade Remote Media Tray Switch enablement status. If the remote disk feature is disabled, this OID cannot be set.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.11INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicy
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.4.2
bladePolicyPowerControlEnable
OBJECT-TYPE
Blade remote power control enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.1INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyMediaTrayControlEnable
OBJECT-TYPE
Blade media tray enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.2INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyKVMControlEnable
OBJECT-TYPE
Blade KVM enablement status policy. Note that some types of blades don't support KVM.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.3INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyWakeOnLanControlEnable
OBJECT-TYPE
Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.4INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bladePolicyMediaTraySwitchEnable
OBJECT-TYPE
Blade Remote Media Tray Switch enablement status policy. If the remote disk feature is disabled, this OID cannot be set.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.5INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyMultipleRemoteVideoEnable
OBJECT-TYPE
Blade multiple remote video sessions enablement status policy. A maximum users can access the video of the same blade from remote console when set to enabled. If it is disabled, only one user can access the video from remote control.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.6INTEGER {disabled(0), enabled(1)}read-writemandatory
bladePolicyAutoPowerOn
OBJECT-TYPE
Blade auto-power on policy. - restore: all blades will be powered on which were previously on. - auto: all blades will automatically be powered on when power is applied to the chassis. - manual: all blades will be left off until manually powered on by the user.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.7INTEGER {restore(1), auto(2), manual(3)}read-writemandatory
bladePolicyDisconnectionMode
OBJECT-TYPE
Blade disconnection mode. - noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection - forcedisconnection: If the blade is already serving a maximum number of users, the requester can disconnect any connected user. - accessRequest: If the blade is already serving an user, this one will get an access request from the requester.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.8INTEGER {noDisconnection(0), forceDisconnection(1), accessRequest(2)}read-writemandatory
bladePolicySessionTimeOut
OBJECT-TYPE
Client session time out in minutes. If there is no remote presence activity, after that time, the session will be closed authomatically.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.9INTEGERread-writemandatory
bladePolicyRequestTimeOut
OBJECT-TYPE
Client connection request time out in seconds. In case of single session mode, if the requested user does not respond within this timeout, the user request will be accepted authomatically.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.10INTEGERread-writemandatory
bladePolicyRetryTimeOut
OBJECT-TYPE
Client connection retry time out in seconds. It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to wait and retry to connect after a while.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.11INTEGERread-writemandatory
bladePolicySessionLostTimeOut
OBJECT-TYPE
Client session lost in minutes. Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the client machine loses a network connection.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.12INTEGERread-writemandatory
bladeMonitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.5
bladeSystemStatusTable
OBJECT-TYPE
Table of blade status information.
1.3.6.1.4.1.2.3.51.2.22.1.5.1not-accessiblemandatory
bladeSystemStatusEntry
OBJECT-TYPE
Blade system status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1not-accessiblemandatory
bladeStatusIndex
OBJECT-TYPE
Blade system status index.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1INTEGERread-onlymandatory
bladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
bladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)}read-onlymandatory
bladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6OCTET STRINGread-onlymandatory
bladeRemotePowerEnable
OBJECT-TYPE
Remote power state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7INTEGER {disabled(0), enabled(1)}read-onlymandatory
bladeRemoteMediaTrayEnable
OBJECT-TYPE
Remote Media Tray state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.8INTEGER {disabled(0), enabled(1)}read-onlymandatory
bladeRemoteKVMEnable
OBJECT-TYPE
Remote keyboard/video/monitor state for the blade. 0x01 indicates enabled. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.9INTEGER {disabled(0), enabled(1)}read-onlymandatory
bladeConnectionType
OBJECT-TYPE
Connection type of the expansion card number one.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeOwnsKVM
OBJECT-TYPE
Indicates whether the MM owns the KVM. 0 = false, 1 = true. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.11INTEGER {false(0), true(1)}read-onlymandatory
bladeOwnsMediaTray
OBJECT-TYPE
Indicates whether the blade owns the Media Tray. 0 = false, 1 = true.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.12INTEGER {false(0), true(1)}read-onlymandatory
bladeRemoteWakeOnLanEnable
OBJECT-TYPE
Remote wake on LAN state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13INTEGER {disabled(0), enabled(1), notApplicable(255)}read-onlymandatory
bladeServerExpansion
OBJECT-TYPE
This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14INTEGER {no(0), yes(1)}read-onlymandatory
bladeWidth
OBJECT-TYPE
The width of the blade including any supplement blade attached to it
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15INTEGERread-onlymandatory
bladeSupportCapacityOnDemand
OBJECT-TYPE
This shows whether this blade support Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.16INTEGER {no(0), yes(1)}read-onlydeprecated
bladeServerExpansion2
OBJECT-TYPE
This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17INTEGER {no(0), yes(1)}read-onlymandatory
bladecKVMStatus
OBJECT-TYPE
This shows whether this blade has a concurrent keyboard, video, and mouse (cKVM) card installed and the status of cKVM on the blade. Not present: A cKVM card is not installed. Not ready: A cKVM card is installed but is not functional. Ready: A cKVM card is installed and is functional, with no cKVM session in progress. Active: A cKVM card is installed and is functional, with a cKVM session currently in progress. Disabled: A cKVM card is not enabled on this blade. Not available: A cKVM card is installed but the status is not available.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.21INTEGER {notPresent(0), notReady(1), ready(2), active(3), disabled(4), notAvailable(255)}read-onlymandatory
bladeConnectionType2
OBJECT-TYPE
Connection type of the expansion card number 2.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType3
OBJECT-TYPE
Connection type of the expansion card number 3.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType4
OBJECT-TYPE
Connection type of the expansion card number 4.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeConnectionType5
OBJECT-TYPE
Connection type of the expansion card number 5.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6)}read-onlymandatory
bladeHighSpeedConnectionType
OBJECT-TYPE
Connection type of the high speed expansion card number 1.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41INTEGER {none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6), infinibandPassThrough(7)}read-onlymandatory
bladeIOCompatibility
OBJECT-TYPE
I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51OCTET STRINGread-onlymandatory
bladeInventoryReady
OBJECT-TYPE
When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52INTEGER {notReady(0), ready(1)}read-onlymandatory
bladeHealthSummaryTable
OBJECT-TYPE
Table of blade health summary information. Contains information about the overall blade health status.
1.3.6.1.4.1.2.3.51.2.22.1.5.2not-accessiblemandatory
bladeHealthSummaryEntry
OBJECT-TYPE
Blade health summary entry
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1not-accessiblemandatory
bladeHealthSummaryIndex
OBJECT-TYPE
Blade health summary index.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1INTEGERread-onlymandatory
bladeHealthSummaryBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeHealthSummarySeverity
OBJECT-TYPE
System health summary severity.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3OCTET STRINGread-onlymandatory
bladeHealthSummaryDescription
OBJECT-TYPE
System health summary description.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4OCTET STRINGread-onlymandatory
bladeHealthSummaryDateTime
OBJECT-TYPE
System health summary date time.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5OCTET STRINGread-onlymandatory
bladeTemperaturesTable
OBJECT-TYPE
Table of blade temperatures information.
1.3.6.1.4.1.2.3.51.2.22.1.5.3not-accessiblemandatory
bladeTemperaturesEntry
OBJECT-TYPE
Blade temperatures table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1not-accessiblemandatory
temperatureIndex
OBJECT-TYPE
Blade temperatures table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1INTEGERread-onlymandatory
temperatureBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
temperatureBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3INTEGER {false(0), true(1)}read-onlymandatory
temperatureBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
temperatureBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5OCTET STRINGread-onlymandatory
temperatureCPU1
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6OCTET STRINGread-onlymandatory
temperatureCPU2
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7OCTET STRINGread-onlymandatory
temperatureCPU3
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8OCTET STRINGread-onlymandatory
temperatureCPU4
OBJECT-TYPE
The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9OCTET STRINGread-onlymandatory
temperatureDASD1
OBJECT-TYPE
The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10OCTET STRINGread-onlymandatory
bladeSensorTempCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12OCTET STRINGread-onlymandatory
bladeSensor2Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13OCTET STRINGread-onlymandatory
bladeSensor3Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14OCTET STRINGread-onlymandatory
bladeSensor4Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15OCTET STRINGread-onlymandatory
bladeSensor5Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16OCTET STRINGread-onlymandatory
bladeSensor6Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17OCTET STRINGread-onlymandatory
bladeSensor7Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18OCTET STRINGread-onlymandatory
bladeSensor8Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19OCTET STRINGread-onlymandatory
bladeSensor9Temp
OBJECT-TYPE
Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20OCTET STRINGread-onlymandatory
bladeTemperatureThresholdsTable
OBJECT-TYPE
Table of blade temperature thresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.4not-accessiblemandatory
bladeTemperatureThresholdsEntry
OBJECT-TYPE
Blade temperature thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1not-accessiblemandatory
temperatureThresholdIndex
OBJECT-TYPE
Blade temperature threshold table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1INTEGERread-onlymandatory
temperatureThresholdBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
temperatureThresholdBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3INTEGER {false(0), true(1)}read-onlymandatory
temperatureThresholdBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
temperatureThresholdBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5OCTET STRINGread-onlymandatory
temperatureCPU1HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6OCTET STRINGread-onlymandatory
temperatureCPU1Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7OCTET STRINGread-onlymandatory
temperatureCPU1WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8OCTET STRINGread-onlymandatory
temperatureCPU2HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9OCTET STRINGread-onlymandatory
temperatureCPU2Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10OCTET STRINGread-onlymandatory
temperatureCPU2WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11OCTET STRINGread-onlymandatory
temperatureCPU3HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12OCTET STRINGread-onlymandatory
temperatureCPU3Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13OCTET STRINGread-onlymandatory
temperatureCPU3WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14OCTET STRINGread-onlymandatory
temperatureCPU4HardShutdown
OBJECT-TYPE
The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15OCTET STRINGread-onlymandatory
temperatureCPU4Warning
OBJECT-TYPE
The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16OCTET STRINGread-onlymandatory
temperatureCPU4WarningReset
OBJECT-TYPE
The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17OCTET STRINGread-onlymandatory
temperatureDASD1HardShutdown
OBJECT-TYPE
The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18OCTET STRINGread-onlymandatory
temperatureDASD1Warning
OBJECT-TYPE
The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19OCTET STRINGread-onlymandatory
temperatureDASD1WarningReset
OBJECT-TYPE
The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20OCTET STRINGread-onlymandatory
bladeTempThresholdSensorCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21INTEGER {false(0), true(1)}read-onlymandatory
temperatureSensor1HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22OCTET STRINGread-onlymandatory
temperatureSensor1Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23OCTET STRINGread-onlymandatory
temperatureSensor1WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24OCTET STRINGread-onlymandatory
temperatureSensor2HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25OCTET STRINGread-onlymandatory
temperatureSensor2Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26OCTET STRINGread-onlymandatory
temperatureSensor2WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27OCTET STRINGread-onlymandatory
temperatureSensor3HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28OCTET STRINGread-onlymandatory
temperatureSensor3Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29OCTET STRINGread-onlymandatory
temperatureSensor3WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30OCTET STRINGread-onlymandatory
temperatureSensor4HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31OCTET STRINGread-onlymandatory
temperatureSensor4Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32OCTET STRINGread-onlymandatory
temperatureSensor4WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33OCTET STRINGread-onlymandatory
temperatureSensor5HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34OCTET STRINGread-onlymandatory
temperatureSensor5Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35OCTET STRINGread-onlymandatory
temperatureSensor5WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36OCTET STRINGread-onlymandatory
temperatureSensor6HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37OCTET STRINGread-onlymandatory
temperatureSensor6Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38OCTET STRINGread-onlymandatory
temperatureSensor6WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39OCTET STRINGread-onlymandatory
temperatureSensor7HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40OCTET STRINGread-onlymandatory
temperatureSensor7Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41OCTET STRINGread-onlymandatory
temperatureSensor7WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42OCTET STRINGread-onlymandatory
temperatureSensor8HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43OCTET STRINGread-onlymandatory
temperatureSensor8Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44OCTET STRINGread-onlymandatory
temperatureSensor8WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45OCTET STRINGread-onlymandatory
temperatureSensor9HardShutdown
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46OCTET STRINGread-onlymandatory
temperatureSensor9Warning
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47OCTET STRINGread-onlymandatory
temperatureSensor9WarningReset
OBJECT-TYPE
The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48OCTET STRINGread-onlymandatory
bladeVoltagesTable
OBJECT-TYPE
Table of blade voltages information.
1.3.6.1.4.1.2.3.51.2.22.1.5.5not-accessiblemandatory
bladeVoltagesEntry
OBJECT-TYPE
Blade voltages table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1not-accessiblemandatory
voltageIndex
OBJECT-TYPE
Blade voltages table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1INTEGERread-onlymandatory
voltageBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
voltageBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3INTEGER {false(0), true(1)}read-onlymandatory
voltageBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
voltageBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5OCTET STRINGread-onlymandatory
bladePlus5Volt
OBJECT-TYPE
+5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6OCTET STRINGread-onlymandatory
bladePlus3pt3Volt
OBJECT-TYPE
+3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7OCTET STRINGread-onlymandatory
bladePlus12Volt
OBJECT-TYPE
+12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8OCTET STRINGread-onlymandatory
bladePlus2pt5Volt
OBJECT-TYPE
+2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10OCTET STRINGread-onlymandatory
bladePlus1pt5Volt
OBJECT-TYPE
+1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11OCTET STRINGread-onlymandatory
bladePlus1pt25Volt
OBJECT-TYPE
+1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12OCTET STRINGread-onlymandatory
bladeVRM1Volt
OBJECT-TYPE
VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13OCTET STRINGread-onlymandatory
bladeSensorVoltCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15OCTET STRINGread-onlymandatory
bladeSensor2Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16OCTET STRINGread-onlymandatory
bladeSensor3Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17OCTET STRINGread-onlymandatory
bladeSensor4Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18OCTET STRINGread-onlymandatory
bladeSensor5Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19OCTET STRINGread-onlymandatory
bladeSensor6Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20OCTET STRINGread-onlymandatory
bladeSensor7Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21OCTET STRINGread-onlymandatory
bladeSensor8Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22OCTET STRINGread-onlymandatory
bladeSensor9Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23OCTET STRINGread-onlymandatory
bladeSensor10Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24OCTET STRINGread-onlymandatory
bladeSensor11Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25OCTET STRINGread-onlymandatory
bladeSensor12Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26OCTET STRINGread-onlymandatory
bladeSensor13Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27OCTET STRINGread-onlymandatory
bladeSensor14Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28OCTET STRINGread-onlymandatory
bladeSensor15Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29OCTET STRINGread-onlymandatory
bladeSensor16Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30OCTET STRINGread-onlymandatory
bladeSensor17Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31OCTET STRINGread-onlymandatory
bladeSensor18Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32OCTET STRINGread-onlymandatory
bladeSensor19Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33OCTET STRINGread-onlymandatory
bladeSensor20Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34OCTET STRINGread-onlymandatory
bladeSensor21Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35OCTET STRINGread-onlymandatory
bladeSensor22Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36OCTET STRINGread-onlymandatory
bladeSensor23Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37OCTET STRINGread-onlymandatory
bladeSensor24Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38OCTET STRINGread-onlymandatory
bladeSensor25Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39OCTET STRINGread-onlymandatory
bladeSensor26Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40OCTET STRINGread-onlymandatory
bladeSensor27Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41OCTET STRINGread-onlymandatory
bladeSensor28Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42OCTET STRINGread-onlymandatory
bladeSensor29Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43OCTET STRINGread-onlymandatory
bladeSensor30Volt
OBJECT-TYPE
Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44OCTET STRINGread-onlymandatory
bladeVoltageThresholdsTable
OBJECT-TYPE
Table of blade VoltageThresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.6not-accessiblemandatory
bladeVoltageThresholdsEntry
OBJECT-TYPE
Blade voltage thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1not-accessiblemandatory
voltageThresholdIndex
OBJECT-TYPE
Blade voltage thresholds table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1INTEGERread-onlymandatory
voltageThresholdBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
voltageThresholdBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3INTEGER {false(0), true(1)}read-onlymandatory
voltageThresholdBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
voltageThresholdBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5OCTET STRINGread-writemandatory
bladePlus5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6OCTET STRINGread-onlymandatory
bladePlus5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7OCTET STRINGread-onlymandatory
bladePlus3pt3VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8OCTET STRINGread-onlymandatory
bladePlus3pt3VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9OCTET STRINGread-onlymandatory
bladePlus12VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10OCTET STRINGread-onlymandatory
bladePlus12VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11OCTET STRINGread-onlymandatory
bladePlus2pt5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14OCTET STRINGread-onlymandatory
bladePlus2pt5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15OCTET STRINGread-onlymandatory
bladePlus1pt5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16OCTET STRINGread-onlymandatory
bladePlus1pt5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17OCTET STRINGread-onlymandatory
bladePlus1pt25VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18OCTET STRINGread-onlymandatory
bladePlus1pt25VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19OCTET STRINGread-onlymandatory
bladeVoltThresholdSensorCapability
OBJECT-TYPE
Indicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22INTEGER {false(0), true(1)}read-onlymandatory
bladeSensor1VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23OCTET STRINGread-onlymandatory
bladeSensor1VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24OCTET STRINGread-onlymandatory
bladeSensor2VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25OCTET STRINGread-onlymandatory
bladeSensor2VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26OCTET STRINGread-onlymandatory
bladeSensor3VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27OCTET STRINGread-onlymandatory
bladeSensor3VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28OCTET STRINGread-onlymandatory
bladeSensor4VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29OCTET STRINGread-onlymandatory
bladeSensor4VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30OCTET STRINGread-onlymandatory
bladeSensor5VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31OCTET STRINGread-onlymandatory
bladeSensor5VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32OCTET STRINGread-onlymandatory
bladeSensor6VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33OCTET STRINGread-onlymandatory
bladeSensor6VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34OCTET STRINGread-onlymandatory
bladeSensor7VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35OCTET STRINGread-onlymandatory
bladeSensor7VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36OCTET STRINGread-onlymandatory
bladeSensor8VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37OCTET STRINGread-onlymandatory
bladeSensor8VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38OCTET STRINGread-onlymandatory
bladeSensor9VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39OCTET STRINGread-onlymandatory
bladeSensor9VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40OCTET STRINGread-onlymandatory
bladeSensor10VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41OCTET STRINGread-onlymandatory
bladeSensor10VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42OCTET STRINGread-onlymandatory
bladeSensor11VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43OCTET STRINGread-onlymandatory
bladeSensor11VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44OCTET STRINGread-onlymandatory
bladeSensor12VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45OCTET STRINGread-onlymandatory
bladeSensor12VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46OCTET STRINGread-onlymandatory
bladeSensor13VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47OCTET STRINGread-onlymandatory
bladeSensor13VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48OCTET STRINGread-onlymandatory
bladeSensor14VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49OCTET STRINGread-onlymandatory
bladeSensor14VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50OCTET STRINGread-onlymandatory
bladeSensor15VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51OCTET STRINGread-onlymandatory
bladeSensor15VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52OCTET STRINGread-onlymandatory
bladeSensor16VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53OCTET STRINGread-onlymandatory
bladeSensor16VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54OCTET STRINGread-onlymandatory
bladeSensor17VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55OCTET STRINGread-onlymandatory
bladeSensor17VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56OCTET STRINGread-onlymandatory
bladeSensor18VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57OCTET STRINGread-onlymandatory
bladeSensor18VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58OCTET STRINGread-onlymandatory
bladeSensor19VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59OCTET STRINGread-onlymandatory
bladeSensor19VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60OCTET STRINGread-onlymandatory
bladeSensor20VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61OCTET STRINGread-onlymandatory
bladeSensor20VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62OCTET STRINGread-onlymandatory
bladeSensor21VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63OCTET STRINGread-onlymandatory
bladeSensor21VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64OCTET STRINGread-onlymandatory
bladeSensor22VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65OCTET STRINGread-onlymandatory
bladeSensor22VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66OCTET STRINGread-onlymandatory
bladeSensor23VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67OCTET STRINGread-onlymandatory
bladeSensor23VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68OCTET STRINGread-onlymandatory
bladeSensor24VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69OCTET STRINGread-onlymandatory
bladeSensor24VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70OCTET STRINGread-onlymandatory
bladeSensor25VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71OCTET STRINGread-onlymandatory
bladeSensor25VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72OCTET STRINGread-onlymandatory
bladeSensor26VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73OCTET STRINGread-onlymandatory
bladeSensor26VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74OCTET STRINGread-onlymandatory
bladeSensor27VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75OCTET STRINGread-onlymandatory
bladeSensor27VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76OCTET STRINGread-onlymandatory
bladeSensor28VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77OCTET STRINGread-onlymandatory
bladeSensor28VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78OCTET STRINGread-onlymandatory
bladeSensor29VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79OCTET STRINGread-onlymandatory
bladeSensor29VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80OCTET STRINGread-onlymandatory
bladeSensor30VoltHighWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81OCTET STRINGread-onlymandatory
bladeSensor30VoltLowWarning
OBJECT-TYPE
Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82OCTET STRINGread-onlymandatory
bladeIOCompatibilityTable
OBJECT-TYPE
Table of IO Compatibility status for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.7not-accessiblemandatory
bladeIOCompatibilityEntry
OBJECT-TYPE
Blade IO Compatibility Status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1not-accessiblemandatory
bladeIOCompatibilityIndex
OBJECT-TYPE
The blade I/O compatibility table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.1INTEGERread-onlymandatory
bladeIOCompatibilityBladeId
OBJECT-TYPE
The blade numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeIOCompatibilityBayNumber
OBJECT-TYPE
The Bay number of the blade or expension card.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.3INTEGERread-onlymandatory
bladeIOCompatibilityModuleBay
OBJECT-TYPE
The modules (each one specified by module type and bay number) that the blade can communicate with over the midplane networking fabric (i.e. a physical path exists between the blade and this module, and hardware exists on the blade to communicate with this module).
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.4OCTET STRINGread-onlymandatory
bladeIOCompatibilityModulePower
OBJECT-TYPE
The power state of the module specified in bladeIOCompatibilityModuleBay. n/a if module not installed.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.5OCTET STRINGread-onlymandatory
bladeIOCompatibilityModuleFabricType
OBJECT-TYPE
The fabric type of the module specified in bladeIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.6OCTET STRINGread-onlymandatory
bladeIOCompatibilityFabricOnBlade
OBJECT-TYPE
The fabric type for this channel on the blade (may be onboard fabric or an expansion card).
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.7OCTET STRINGread-onlymandatory
bladeIOCompatibilityStatus
OBJECT-TYPE
The compatibility status between the blade and the module specified in bladeIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the blade. n/a: (Not applicable) The module specified in bladeIOCompatibilityModuleBay is a bridge, so the blade port cannot connect to it. Attention: The module specified in bladeIOCompatibilityModuleBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in bladeIOCompatibilityModuleBay is of unknown type Unknown fabric type on the blade
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.8OCTET STRINGread-onlymandatory
bladePowerRestart
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.6
bladePowerRestartTable
OBJECT-TYPE
Table of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1not-accessiblemandatory
bladePowerRestartEntry
OBJECT-TYPE
Blade power restart table entry
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1not-accessiblemandatory
powerRestartIndex
OBJECT-TYPE
Blade power restart table index.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1INTEGERread-onlymandatory
powerRestartBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
powerRestartBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
powerRestartBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) value is returned.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
powerRestartBladeHealthState
OBJECT-TYPE
The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5INTEGER {unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11)}read-onlymandatory
powerRestartBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6OCTET STRINGread-onlymandatory
powerOnOffBlade
OBJECT-TYPE
Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s)
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7INTEGER {off(0), on(1), softoff(2)}read-writemandatory
restartBlade
OBJECT-TYPE
Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8INTEGER {execute(1)}read-writemandatory
restartBladeSMP
OBJECT-TYPE
Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9INTEGER {execute(1)}read-writemandatory
restartBladeNMI
OBJECT-TYPE
Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10INTEGER {execute(1)}read-writemandatory
restartBladeClearNVRAM
OBJECT-TYPE
Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11INTEGER {execute(1)}read-writemandatory
restartBladeInvokeDiags
OBJECT-TYPE
Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12INTEGER {execute(1)}read-writemandatory
restartBladeInvokeDiagsFromDefaultBootList
OBJECT-TYPE
Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13INTEGER {execute(1)}read-writemandatory
restartBladeToSMSBootMenu
OBJECT-TYPE
Restart a blade to SMS boot menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14INTEGER {execute(1)}read-writemandatory
restartBladeToUEFIMenu
OBJECT-TYPE
Restart a blade to UEFI setup menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15INTEGER {execute(1)}read-writemandatory
bladeConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.7
bladeConfigurationTable
OBJECT-TYPE
Table of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.1not-accessiblemandatory
bladeConfigurationEntry
OBJECT-TYPE
Blade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1not-accessiblemandatory
configurationIndex
OBJECT-TYPE
Blade configuration table index.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1INTEGERread-onlymandatory
configurationBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
configurationBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
configurationBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
configurationBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5OCTET STRINGread-writemandatory
configurationBladecKVM
OBJECT-TYPE
Enable or disable the concurrent KVM function on specified blade. If concurrent KVM is not supported by the blade, it displays 'notPresent' and the concurrent KVM functionality can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.6INTEGER {disable(0), enable(1), notPresent(2)}read-writemandatory
configurationBladeActiveBootMode
OBJECT-TYPE
Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7INTEGER {temporary(1), permanent(2), notApplicable(255)}read-onlymandatory
configurationBladePendingBootMode
OBJECT-TYPE
Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8INTEGER {temporary(1), permanent(2), notApplicable(255)}read-writemandatory
bladePowerManagementPolicy
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.7.2
powerdomain1Oversubscription
OBJECT-TYPE
Power Management Policy settings for power domain 1.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.1INTEGER {not-allowed(0), recoverable(1), non-recoverable(2)}read-writemandatory
powerdomain2Oversubscription
OBJECT-TYPE
Power Management Policy settings for power domain 2.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.2INTEGER {not-allowed(0), recoverable(1), non-recoverable(2)}read-writemandatory
acousticMode
OBJECT-TYPE
Acoustic mode setting for thermal conditions
1.3.6.1.4.1.2.3.51.2.22.1.7.2.3INTEGER {disabled(0), enabled(1)}read-writemandatory
nebsMode
OBJECT-TYPE
NEBS (Network Equipment-Building System) mode setting for thermal conditions. NOTE: This MIB object is for BladeCenter T, HT and TR only.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.4INTEGER {disabled(0), enabled(1)}read-writemandatory
bladecKVMEnableDisable
OBJECT-TYPE
Enable or disable cKVM function on all server blades.
1.3.6.1.4.1.2.3.51.2.22.1.7.3INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPAddrRangeStart
OBJECT-TYPE
This field is used to configure the start of the IP address range for the blade system management processors on the blades. These addresses are used on the internal management network between the MM and the blade BSMPs. For example the value of 10.10.10.1 means the BSMP on the blade in bay 1 will have IP address 10.10.10.1, the BSMP on the blade in bay 2 will have IP address 10.10.10.2 and so on. This field is deprecated and no longer supported. An attempt to SET this object will be rejected, and any query will always return 0.0.0.0. Refer to the bladeManagementNetworkInfoTable for the new objects providing this information.
1.3.6.1.4.1.2.3.51.2.22.1.8IpAddressread-onlydeprecated
bladeCapacityOnDemand
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.9
bladeCapacityOnDemandTable
OBJECT-TYPE
Table of COD blade. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1not-accessibledeprecated
bladeCapacityOnDemandEntry
OBJECT-TYPE
Blade COD table entry NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1not-accessibledeprecated
bladeCapacityOnDemandIndex
OBJECT-TYPE
Blade configuration table index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.1INTEGERread-onlydeprecated
bladeCapacityOnDemandBladeName
OBJECT-TYPE
The name of the blade as a null terminated string. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.2OCTET STRINGread-onlydeprecated
bladeCapacityOnDemandState
OBJECT-TYPE
The state of Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.3INTEGER {none(0), standby(1), active(2)}read-writedeprecated
bladeBootCountPowerOnTime
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.10
bladeBootCountPowerOnTimeTable
OBJECT-TYPE
Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1not-accessiblemandatory
bladeBootCountPowerOnTimeEntry
OBJECT-TYPE
The number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1not-accessiblemandatory
bootCountPowerOnTimeBladeIndex
OBJECT-TYPE
Blade boot count/Power On Time table index.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1INTEGERread-onlymandatory
bootCountPowerOnTimeBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bootCountPowerOnTimeBoots
OBJECT-TYPE
Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3INTEGERread-writemandatory
bootCountPowerOnTimeSecs
OBJECT-TYPE
Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4INTEGERread-writemandatory
bladeVlanId
OBJECT-TYPE
This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.11INTEGERread-writemandatory
bladeNetworkConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.12
bladeNetworkInterfaceTable
OBJECT-TYPE
Table of all blades' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.1.12.2not-accessiblemandatory
bladeNetworkInterfaceEntry
OBJECT-TYPE
Blade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1not-accessiblemandatory
bladeNetworkInterfaceIndex
OBJECT-TYPE
Blade Network Interface Table index.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.1INTEGERread-onlymandatory
bladeNetworkInterfaceBayNumber
OBJECT-TYPE
The bay number of the main server blade that supports network interface management
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.2OCTET STRINGread-onlymandatory
bladeNetworkInterfaceNumber
OBJECT-TYPE
Indicates which network interface on the blade System Management Processor is be read or writen
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.3INTEGERread-onlymandatory
bladeNetworkInterfaceType
OBJECT-TYPE
Indicates blade network interface type.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.4INTEGER {private(1), public(2)}read-onlymandatory
bladeNetworkInterfaceLabel
OBJECT-TYPE
Show string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.5OCTET STRINGread-onlymandatory
bladeNetworkInterfaceIPAddr
OBJECT-TYPE
Show/modify current IP address of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the IP address be pushed down to blade System Management Processor
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.6IpAddressread-writemandatory
bladeNetworkInterfaceSubnetMask
OBJECT-TYPE
Show or modifie current subnet mask of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the SunnetMask be pushed down to blade System Management Processor
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.7IpAddressread-writemandatory
bladeNetworkInterfaceGatewayAddr
OBJECT-TYPE
Show or modify current IP gateway of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the Gateway address be pushed down to blade System Management Processor
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.8IpAddressread-writemandatory
bladeNetworkInterfaceVlanId
OBJECT-TYPE
This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.9INTEGERread-writemandatory
bladeNetworkInterfaceVlanEnable
OBJECT-TYPE
This object is no longer supported and will always be 0
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.10INTEGER {disabled(0), enabled(1), notApplicable(255)}read-onlydeprecated
bladeNetworkInterfaceEnable
OBJECT-TYPE
Disabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations. If this network interface doesn't support enabled/disabled, show 'notApplicable(255)'
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.11INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bladeNetworkInterfaceDHCPEnable
OBJECT-TYPE
IP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic. If this network interface doesn't support DHCP, show 'notApplicable(255)'
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.12INTEGER {dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2), notApplicable(255)}read-writemandatory
bladeNetworkInterfaceMACAddr
OBJECT-TYPE
Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.13OCTET STRINGread-onlymandatory
bladeNetworkInterfaceAssignedSwitch
OBJECT-TYPE
This field allows you to select an I/O Module to use for management traffic to the blade. NOTE: This field is only supported for eth1 of blade. NOTE: You may only specify ethernet switches to this field.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.14INTEGER {notAssigned(0), module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10), notApplicable(255)}read-writemandatory
bladeIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.12.10
bladeIPv6ConfigTable
OBJECT-TYPE
A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1not-accessiblemandatory
bladeIPv6ConfigEntry
OBJECT-TYPE
IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1not-accessiblemandatory
bladeIPv6ConfigIndex
OBJECT-TYPE
The blade's slot number
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1INTEGERread-onlymandatory
bladeIPv6ConfigPortIndex
OBJECT-TYPE
The physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2INTEGERread-onlymandatory
bladeIPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables IPv6 support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6ConfigStatic
OBJECT-TYPE
Enables/Disables IPv6 static configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4INTEGER {disable(0), enable(1)}read-writemandatory
bladeDHCPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables DHCPv6 address configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6ConfigStatelessEnabled
OBJECT-TYPE
Enables/Disables IPv6 stateless auto-configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6INTEGER {disable(0), enable(1)}read-writemandatory
bladeIPv6AddressTable
OBJECT-TYPE
A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2not-accessiblemandatory
bladeIPv6AddressEntry
OBJECT-TYPE
The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1not-accessiblemandatory
bladeIPv6AddressIndex
OBJECT-TYPE
The blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1INTEGERread-onlymandatory
bladeIPv6AddressPortIndex
OBJECT-TYPE
The blade's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2INTEGERread-onlymandatory
bladeIPv6AddressEntryIndex
OBJECT-TYPE
The blade's address entry index.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3INTEGERread-onlymandatory
bladeIPv6AddressType
OBJECT-TYPE
The address type.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4INTEGER {active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5)}read-onlymandatory
bladeIPv6Address
OBJECT-TYPE
The assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5InetAddressIPv6read-writemandatory
bladeIPv6AddressPrefixLen
OBJECT-TYPE
The prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6INTEGER (1..128)read-writemandatory
bladeIPv6AddressDefaultRoute
OBJECT-TYPE
The default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7InetAddressIPv6read-writemandatory
bladeBayDataTable
OBJECT-TYPE
Table of blade bay data (BBD) information.
1.3.6.1.4.1.2.3.51.2.22.1.13not-accessiblemandatory
bladeBayDataEntry
OBJECT-TYPE
Blade bay data (BBD) table entry.
1.3.6.1.4.1.2.3.51.2.22.1.13.1not-accessiblemandatory
bayDataIndex
OBJECT-TYPE
Blade bay data (BBD) table index.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.1INTEGERread-onlymandatory
bayDataBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bayDataBladeExists
OBJECT-TYPE
Indicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.3INTEGER {false(0), true(1)}read-onlymandatory
bayDataBladePowerState
OBJECT-TYPE
Indicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.4INTEGER {off(0), on(1), standby(3), hibernate(4)}read-onlymandatory
bayDataBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.5OCTET STRINGread-onlymandatory
bayData
OBJECT-TYPE
A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.6OCTET STRINGread-writemandatory
bayDataBladeStatus
OBJECT-TYPE
This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.7INTEGER {supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255)}read-onlymandatory
bladeSPEthOverUSBInterface
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.14
spEthOverUSBInterfaceTable
OBJECT-TYPE
Table of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.1.14.1not-accessiblemandatory
spEthOverUSBInterfaceEntry
OBJECT-TYPE
Blade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1not-accessiblemandatory
spEthOverUSBInterfaceIndex
OBJECT-TYPE
Service Processor's Ethernet over USB interface table index.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1INTEGERread-onlymandatory
spEthOverUSBInterfaceBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2OCTET STRINGread-onlymandatory
spEthOverUSBInterfaceBladeExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
spEthOverUSBInterfaceBladeName
OBJECT-TYPE
The name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6OCTET STRINGread-onlymandatory
spEthOverUSBInterfaceEnable
OBJECT-TYPE
This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9INTEGER {disabled(0), enabled(1), notApplicable(255)}read-writemandatory
bladeManagementNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.1.15
bladeManagementNetworkControlEnable
OBJECT-TYPE
Globally disable/enable blade management network auto discovery support.
1.3.6.1.4.1.2.3.51.2.22.1.15.1INTEGER {disabled(0), enabled(1)}read-writemandatory
bladeManagementNetworkInfoTable
OBJECT-TYPE
Table of blade management network information.
1.3.6.1.4.1.2.3.51.2.22.1.15.2not-accessiblemandatory
bladeManagementNetworkInfoEntry
OBJECT-TYPE
Blade management network information entry.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1not-accessiblemandatory
bladeManagementNetworkInfoIndex
OBJECT-TYPE
Blade management network information table index
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.1INTEGERread-onlymandatory
bladeManagementNetworkInfoBladeId
OBJECT-TYPE
The Blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
bladeManagementNetworkInfoBladeExist
OBJECT-TYPE
Indicates whether the blade specified exists or not in the chassis.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.3INTEGERread-onlymandatory
bladeManagementNetworkInfoBladeSupport
OBJECT-TYPE
Indicates whether the blade supports the management network auto discovery capability or not.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.4INTEGERread-onlymandatory
bladeManagementNetworkInfoPathStatus
OBJECT-TYPE
Indicates the status of the management network for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.5INTEGER {down(0), up(1)}read-onlymandatory
bladeManagementNetworkInfoBladeIPAddr
OBJECT-TYPE
Indicates the blade system management processor IPv4 address.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.6IpAddressread-onlymandatory
bladeManagementNetworkInfoBladeMACAddr
OBJECT-TYPE
Indicates the blade system management processor MAC address.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.7OCTET STRINGread-onlymandatory
bladeManagementNetworkInfoSwitchId
OBJECT-TYPE
Indicates which switch is selected for the blade management network.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.8INTEGERread-onlymandatory
switchModule
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3
switchModuleControl
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.1
smControlTable
OBJECT-TYPE
Switch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.1not-accessiblemandatory
smControlEntry
OBJECT-TYPE
Switch module control table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1not-accessiblemandatory
smControlIndex
OBJECT-TYPE
Switch module control table index.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1INTEGERread-onlymandatory
switchModuleControlId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smPostResultsAvailable
OBJECT-TYPE
Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smPostResultsValue
OBJECT-TYPE
The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4OCTET STRINGread-onlymandatory
switchModuleMemDiagEnableDisable
OBJECT-TYPE
Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5INTEGER {enabled(0), disabled(1)}read-writemandatory
smCfgCtrlEnableDisable
OBJECT-TYPE
Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6INTEGER {disabled(0), enabled(1)}read-writemandatory
smExtEthPortsEnableDisable
OBJECT-TYPE
Switch module external ethernet ports enabled or disabled. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7INTEGER {disabled(0), enabled(1)}read-writemandatory
switchPingRequest
OBJECT-TYPE
Sends a ping to a switch module's current IPv4 address. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and IP Configuration is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This object has been deprecated in favor of the new table smPingTable which supports IPv6 and IPv4 addresses.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.8INTEGER {execute(1)}read-writedeprecated
smCfgCtrlOnResetEnableDisable
OBJECT-TYPE
Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9INTEGER {enabled(0), disabled(1)}read-writemandatory
smHealthState
OBJECT-TYPE
The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
smPMState
OBJECT-TYPE
The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the AMM. pending - Protected Mode has been activated on the AMM but not yet on the switch module. active - Protected Mode is active on both the switch module and the AMM. attention - Protected Mode is enabled on the switch module but not on the AMM.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16INTEGER {disabled(0), pending(1), attention(2), active(3), notApplicable(255)}read-onlymandatory
smPMCtrlEnableDisable
OBJECT-TYPE
AMM Protected Mode permission for the switch module. disabled - allow AMM to disable Protected Mode Permission for the switch module. enabled - allow AMM to grant Protected Mode Permission for the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17INTEGER {disabled(0), enabled(1)}read-writemandatory
smIOCompatibility
OBJECT-TYPE
The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18OCTET STRINGread-onlymandatory
smPingTable
OBJECT-TYPE
Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.1.2not-accessiblemandatory
smPingEntry
OBJECT-TYPE
Represents a single address that can be pinged
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1not-accessiblemandatory
smPingIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1INTEGERread-onlymandatory
smPingAddressEntryIndex
OBJECT-TYPE
The switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2INTEGERread-onlymandatory
smPingAddress
OBJECT-TYPE
The switch module's IPv4 or IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3OCTET STRINGread-onlymandatory
smPingAddressExecute
OBJECT-TYPE
Pings the given IP address. NOTE: The GET operation for this object is meaningless.
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4INTEGER {execute(1)}read-writemandatory
smPowerRestartTable
OBJECT-TYPE
Switch module power restart table.
1.3.6.1.4.1.2.3.51.2.22.3.1.7not-accessiblemandatory
smPowerRestartEntry
OBJECT-TYPE
Switch module power restart table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1not-accessiblemandatory
smPowerRestartIndex
OBJECT-TYPE
Switch module power restart index.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1INTEGERread-onlymandatory
smPowerRestartId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smSwitchExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3INTEGER {false(0), true(1)}read-onlymandatory
smSwitchType
OBJECT-TYPE
Switch module type.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.4INTEGER {unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40)}read-onlymandatory
smMACAddress
OBJECT-TYPE
Switch module MAC address.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5OCTET STRINGread-onlymandatory
smIPAddress
OBJECT-TYPE
The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6IpAddressread-onlymandatory
switchModulePowerOnOff
OBJECT-TYPE
I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. For example, SAS Controller Modules must flush pending I/O before powering off in order to maintain data integrity. The value'shutdownInProgress' can not be used to set. If both SAS Controller Module and SAS Connectivity Module are installed in slot 3 and 4 of BCS chassis, AMM must prevent one of them from powering on otherwise there would be conflict with the Storage Module access and possibly corruption of data. This MIB object can not be set, if AMM grants the I/O Module the Protected Mode permission and module goes into Protected Mode.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7INTEGER {poweroff(0), poweron(1), shutdownInProgress(2)}read-writemandatory
smReset
OBJECT-TYPE
For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8INTEGER {execute(1)}read-writemandatory
smResetToDefault
OBJECT-TYPE
For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9INTEGER {execute(1)}read-writemandatory
smRestartAndRunStdDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10INTEGER {execute(1)}read-writemandatory
smRestartAndRunExtDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11INTEGER {execute(1)}read-writemandatory
smRestartAndRunFullDiag
OBJECT-TYPE
To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12INTEGER {execute(1)}read-writemandatory
smSwitchSubType
OBJECT-TYPE
Switch module subtype. NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.20INTEGER {unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9)}read-onlymandatory
smSwitchWidth
OBJECT-TYPE
Switch module width.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21INTEGERread-onlymandatory
smManufacturingID
OBJECT-TYPE
Switch module hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22OCTET STRINGread-onlymandatory
smStackingModeState
OBJECT-TYPE
The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23INTEGER {standby(0), member(1), master(2), notApplicable(255)}read-onlymandatory
smStackingModeInfo
OBJECT-TYPE
A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24OCTET STRINGread-onlymandatory
smIOCompatibilityTable
OBJECT-TYPE
Switch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.10not-accessiblemandatory
smIOCompatibilityEntry
OBJECT-TYPE
Switch module IO compatibility table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1not-accessiblemandatory
smIOCompatibilityIndex
OBJECT-TYPE
Switch module IO compatibility index.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1INTEGERread-onlymandatory
smIOCompatibilityId
OBJECT-TYPE
The switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smIOCompatibilityModuleBay
OBJECT-TYPE
The modules (each one specified by module type and bay number) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module).
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3OCTET STRINGread-onlymandatory
smIOCompatibilityModulePower
OBJECT-TYPE
The power state of the module specified in smIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4OCTET STRINGread-onlymandatory
smIOCompatibilityModuleFabricType
OBJECT-TYPE
The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot).
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5OCTET STRINGread-onlymandatory
smIOCompatibilityStatus
OBJECT-TYPE
The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6OCTET STRINGread-onlymandatory
switchModuleConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2
switchMgmtNetworkCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1
switchCurrentNwCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1
smCurrentIPInfoTable
OBJECT-TYPE
Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1not-accessiblemandatory
smCurrentIPInfoEntry
OBJECT-TYPE
Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1not-accessiblemandatory
smCurrentIPInfoIndex
OBJECT-TYPE
Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1INTEGERread-onlymandatory
smCurrentIPInfoId
OBJECT-TYPE
The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smCurrentIPInfoExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smCurrentIPInfoPowerState
OBJECT-TYPE
Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. Such as SAS Controller Modules, that must flush pending I/O before powering off in order to maintain data integrity. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4INTEGER {off(0), on(1), shutdownInProgress(2)}read-onlymandatory
smCurrentIPAddr
OBJECT-TYPE
The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6IpAddressread-onlymandatory
smCurrentSubnetMask
OBJECT-TYPE
The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7IpAddressread-onlymandatory
smCurrentGateway
OBJECT-TYPE
The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8IpAddressread-onlymandatory
smCurrentIPConfigMethod
OBJECT-TYPE
The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)}read-onlymandatory
switchNewNwCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2
smNewIPInfoTable
OBJECT-TYPE
Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1not-accessiblemandatory
smNewIPInfoEntry
OBJECT-TYPE
Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1not-accessiblemandatory
smNewIPInfoIndex
OBJECT-TYPE
Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1INTEGERread-onlymandatory
smNewIPInfoId
OBJECT-TYPE
The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNewIPInfoExists
OBJECT-TYPE
Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNewIPInfoPowerState
OBJECT-TYPE
Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected..
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNewIPAddr
OBJECT-TYPE
The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6IpAddressread-writemandatory
smNewSubnetMask
OBJECT-TYPE
The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7IpAddressread-writemandatory
smNewGateway
OBJECT-TYPE
The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8IpAddressread-writemandatory
smNewIPConfigMethod
OBJECT-TYPE
The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9INTEGER {unknown(0), static(1), dhcp(2), nat(3), bootp(4)}read-writemandatory
smNewIPConfigEnableDisable
OBJECT-TYPE
A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10INTEGER {disable(0), enable(1)}read-writemandatory
switchNwProtCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3
switchNwProtCfgModOne
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1
smNwProtInfoModOneTable
OBJECT-TYPE
Switch module 1 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1not-accessiblemandatory
smNwProtInfoModOneEntry
OBJECT-TYPE
Switch module 1 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1not-accessiblemandatory
smNwProtInfoModOneIndex
OBJECT-TYPE
Switch module 1 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.1INTEGERread-onlymandatory
smNwProtInfoModOneId
OBJECT-TYPE
The switch module 1 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModOneExists
OBJECT-TYPE
Indicates whether the switch module 1 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModOnePowerState
OBJECT-TYPE
Indicates whether the switch module 1 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModOneProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModOneProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModOneExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.7INTEGERread-writemandatory
smNwProtInfoModOneIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.8INTEGERread-writemandatory
smNwProtInfoModOneEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModOneActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModOneReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModTwo
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2
smNwProtInfoModTwoTable
OBJECT-TYPE
Switch module 2 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1not-accessiblemandatory
smNwProtInfoModTwoEntry
OBJECT-TYPE
Switch module 2 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1not-accessiblemandatory
smNwProtInfoModTwoIndex
OBJECT-TYPE
Switch module 2 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.1INTEGERread-onlymandatory
smNwProtInfoModTwoId
OBJECT-TYPE
The switch module 2 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModTwoExists
OBJECT-TYPE
Indicates whether the switch module 2 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModTwoPowerState
OBJECT-TYPE
Indicates whether the switch module 2 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModTwoProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModTwoProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModTwoExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.7INTEGERread-writemandatory
smNwProtInfoModTwoIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.8INTEGERread-writemandatory
smNwProtInfoModTwoEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModTwoActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModTwoReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModThree
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3
smNwProtInfoModThreeTable
OBJECT-TYPE
Switch module 3 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1not-accessiblemandatory
smNwProtInfoModThreeEntry
OBJECT-TYPE
Switch module 3 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1not-accessiblemandatory
smNwProtInfoModThreeIndex
OBJECT-TYPE
Switch module 3 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.1INTEGERread-onlymandatory
smNwProtInfoModThreeId
OBJECT-TYPE
The switch module 3 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModThreeExists
OBJECT-TYPE
Indicates whether the switch module 3 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModThreePowerState
OBJECT-TYPE
Indicates whether the switch module 3 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModThreeProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModThreeProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModThreeExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.7INTEGERread-writemandatory
smNwProtInfoModThreeIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.8INTEGERread-writemandatory
smNwProtInfoModThreeEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModThreeActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModThreeReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModFour
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4
smNwProtInfoModFourTable
OBJECT-TYPE
Switch module 4 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1not-accessiblemandatory
smNwProtInfoModFourEntry
OBJECT-TYPE
Switch module 3 network protocol (Network Address Translation) configuration information table entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1not-accessiblemandatory
smNwProtInfoModFourIndex
OBJECT-TYPE
Switch module 4 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.1INTEGERread-onlymandatory
smNwProtInfoModFourId
OBJECT-TYPE
The switch module 4 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModFourExists
OBJECT-TYPE
Indicates whether the switch module 4 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModFourPowerState
OBJECT-TYPE
Indicates whether the switch module 4 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModFourProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModFourProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModFourExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.7INTEGERread-writemandatory
smNwProtInfoModFourIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.8INTEGERread-writemandatory
smNwProtInfoModFourEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModFourActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModFourReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModFive
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5
smNwProtInfoModFiveTable
OBJECT-TYPE
Switch module 5 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1not-accessiblemandatory
smNwProtInfoModFiveEntry
OBJECT-TYPE
Switch module 5 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1not-accessiblemandatory
smNwProtInfoModFiveIndex
OBJECT-TYPE
Switch module 5 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.1INTEGERread-onlymandatory
smNwProtInfoModFiveId
OBJECT-TYPE
The switch module 5 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModFiveExists
OBJECT-TYPE
Indicates whether the switch module 5 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModFivePowerState
OBJECT-TYPE
Indicates whether the switch module 5 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModFiveProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModFiveProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModFiveExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.7INTEGERread-writemandatory
smNwProtInfoModFiveIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.8INTEGERread-writemandatory
smNwProtInfoModFiveEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModFiveActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModFiveReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModSix
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6
smNwProtInfoModSixTable
OBJECT-TYPE
Switch module 6 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1not-accessiblemandatory
smNwProtInfoModSixEntry
OBJECT-TYPE
Switch module 6 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1not-accessiblemandatory
smNwProtInfoModSixIndex
OBJECT-TYPE
Switch module 6 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.1INTEGERread-onlymandatory
smNwProtInfoModSixId
OBJECT-TYPE
The switch module 6 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModSixExists
OBJECT-TYPE
Indicates whether the switch module 6 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModSixPowerState
OBJECT-TYPE
Indicates whether the switch module 6 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModSixProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModSixProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModSixExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.7INTEGERread-writemandatory
smNwProtInfoModSixIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.8INTEGERread-writemandatory
smNwProtInfoModSixEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModSixActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModSixReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModSeven
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7
smNwProtInfoModSevenTable
OBJECT-TYPE
Switch module 7 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1not-accessiblemandatory
smNwProtInfoModSevenEntry
OBJECT-TYPE
Switch module 7 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1not-accessiblemandatory
smNwProtInfoModSevenIndex
OBJECT-TYPE
Switch module 7 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.1INTEGERread-onlymandatory
smNwProtInfoModSevenId
OBJECT-TYPE
The switch module 7 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModSevenExists
OBJECT-TYPE
Indicates whether the switch module 7 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModSevenPowerState
OBJECT-TYPE
Indicates whether the switch module 7 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModSevenProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModSevenProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModSevenExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.7INTEGERread-writemandatory
smNwProtInfoModSevenIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.8INTEGERread-writemandatory
smNwProtInfoModSevenEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModSevenActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModSevenReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModEight
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8
smNwProtInfoModEightTable
OBJECT-TYPE
Switch module 8 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1not-accessiblemandatory
smNwProtInfoModEightEntry
OBJECT-TYPE
Switch module 8 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1not-accessiblemandatory
smNwProtInfoModEightIndex
OBJECT-TYPE
Switch module 8 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.1INTEGERread-onlymandatory
smNwProtInfoModEightId
OBJECT-TYPE
The switch module 8 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModEightExists
OBJECT-TYPE
Indicates whether the switch module 8 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModEightPowerState
OBJECT-TYPE
Indicates whether the switch module 8 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModEightProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModEightProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModEightExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.7INTEGERread-writemandatory
smNwProtInfoModEightIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.8INTEGERread-writemandatory
smNwProtInfoModEightEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModEightActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModEightReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModNine
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9
smNwProtInfoModNineTable
OBJECT-TYPE
Switch module 9 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1not-accessiblemandatory
smNwProtInfoModNineEntry
OBJECT-TYPE
Switch module 9 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1not-accessiblemandatory
smNwProtInfoModNineIndex
OBJECT-TYPE
Switch module 9 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.1INTEGERread-onlymandatory
smNwProtInfoModNineId
OBJECT-TYPE
The switch module 9 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModNineExists
OBJECT-TYPE
Indicates whether the switch module 9 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModNinePowerState
OBJECT-TYPE
Indicates whether the switch module 9 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModNineProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModNineProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModNineExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.7INTEGERread-writemandatory
smNwProtInfoModNineIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.8INTEGERread-writemandatory
smNwProtInfoModNineEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModNineActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModNineReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.3INTEGER {execute(1)}read-writemandatory
switchNwProtCfgModTen
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10
smNwProtInfoModTenTable
OBJECT-TYPE
Switch module 10 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1not-accessiblemandatory
smNwProtInfoModTenEntry
OBJECT-TYPE
Switch module 10 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1not-accessiblemandatory
smNwProtInfoModTenIndex
OBJECT-TYPE
Switch module 10 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.1INTEGERread-onlymandatory
smNwProtInfoModTenId
OBJECT-TYPE
The switch module 10 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.2INTEGER {module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10)}read-onlymandatory
smNwProtInfoModTenExists
OBJECT-TYPE
Indicates whether the switch module 10 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
smNwProtInfoModTenPowerState
OBJECT-TYPE
Indicates whether the switch module 10 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.4INTEGER {off(0), on(1)}read-onlymandatory
smNwProtInfoModTenProtName
OBJECT-TYPE
Protocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.5OCTET STRINGread-writemandatory
smNwProtInfoModTenProtID
OBJECT-TYPE
Protocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.6INTEGER {tcp(2), udp(3)}read-writemandatory
smNwProtInfoModTenExtPort
OBJECT-TYPE
External port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.7INTEGERread-writemandatory
smNwProtInfoModTenIntPort
OBJECT-TYPE
Internal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.8INTEGERread-writemandatory
smNwProtInfoModTenEnable
OBJECT-TYPE
Enable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.9INTEGER {disable(0), enable(1)}read-writemandatory
smNwProtInfoModTenActivate
OBJECT-TYPE
Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.2INTEGER {execute(1)}read-writemandatory
smNwProtInfoModTenReset
OBJECT-TYPE
Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.3INTEGER {execute(1)}read-writemandatory
switchIPv6Config
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4
smIPv6ConfigTable
OBJECT-TYPE
A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1not-accessiblemandatory
smIPv6ConfigEntry
OBJECT-TYPE
IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1not-accessiblemandatory
smIPv6ConfigIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1INTEGERread-onlymandatory
smIPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables IPv6 support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2INTEGER {disable(0), enable(1)}read-writemandatory
smIPv6ConfigStatic
OBJECT-TYPE
Enables/Disables IPv6 static configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3INTEGER {disable(0), enable(1)}read-writemandatory
smDHCPv6ConfigEnabled
OBJECT-TYPE
Enables/Disables DHCPv6 address configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4INTEGER {disable(0), enable(1)}read-writemandatory
smIPv6ConfigStatelessEnabled
OBJECT-TYPE
Enables/Disables IPv6 stateless auto-configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5INTEGER {disable(0), enable(1)}read-writemandatory
smIPv6AddressTable
OBJECT-TYPE
A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2not-accessiblemandatory
smIPv6AddressEntry
OBJECT-TYPE
The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1not-accessiblemandatory
smIPv6AddressIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1INTEGERread-onlymandatory
smIPv6AddressEntryIndex
OBJECT-TYPE
The switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2INTEGERread-onlymandatory
smIPv6AddressType
OBJECT-TYPE
The address type.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3INTEGER {static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5)}read-onlymandatory
smIPv6Address
OBJECT-TYPE
The assigned IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4InetAddressIPv6read-onlymandatory
smIPv6AddressPrefixLen
OBJECT-TYPE
The prefix length for the given address.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5INTEGERread-onlymandatory
smIPv6AddressDefaultRoute
OBJECT-TYPE
The default route used for the given address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6InetAddressIPv6read-onlymandatory
smIPv6StaticConfigTable
OBJECT-TYPE
Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3not-accessiblemandatory
smIPv6StaticConfigEntry
OBJECT-TYPE
The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1not-accessiblemandatory
smIPv6StaticIndex
OBJECT-TYPE
The switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1INTEGERread-onlymandatory
smIPv6StaticAddress
OBJECT-TYPE
The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2InetAddressIPv6read-writemandatory
smIPv6StaticAddressPrefixLen
OBJECT-TYPE
The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3INTEGERread-writemandatory
smIPv6StaticAddressDefaultRoute
OBJECT-TYPE
The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4InetAddressIPv6read-writemandatory
switchPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2
switchModOnePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1
smOnePortCfgTable
OBJECT-TYPE
Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1not-accessiblemandatory
smOnePortCfgEntry
OBJECT-TYPE
Switch Module 1 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1not-accessiblemandatory
smOnePortCfgIndex
OBJECT-TYPE
Switch Module 1 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1INTEGERread-onlymandatory
smOnePortCfgLabel
OBJECT-TYPE
Switch Module 1 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2OCTET STRINGread-onlymandatory
smOnePortCfgType
OBJECT-TYPE
Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smOnePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smOnePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smOnePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6OCTET STRINGread-writemandatory
smOnePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7OCTET STRINGread-onlymandatory
smOnePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8OCTET STRINGread-onlymandatory
smOnePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smOnePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smOnePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11INTEGERread-onlymandatory
smOnePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12INTEGERread-onlymandatory
smOnePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13OCTET STRINGread-onlymandatory
smOnePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14OCTET STRINGread-onlymandatory
smOnePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smOnePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModTwoPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2
smTwoPortCfgTable
OBJECT-TYPE
Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1not-accessiblemandatory
smTwoPortCfgEntry
OBJECT-TYPE
Switch Module 2 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1not-accessiblemandatory
smTwoPortCfgIndex
OBJECT-TYPE
Switch Module 2 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1INTEGERread-onlymandatory
smTwoPortCfgLabel
OBJECT-TYPE
Switch Module 2 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2OCTET STRINGread-onlymandatory
smTwoPortCfgType
OBJECT-TYPE
Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smTwoPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smTwoPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smTwoPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6OCTET STRINGread-writemandatory
smTwoPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7OCTET STRINGread-onlymandatory
smTwoPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8OCTET STRINGread-onlymandatory
smTwoPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smTwoPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smTwoPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11INTEGERread-onlymandatory
smTwoPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12INTEGERread-onlymandatory
smTwoPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13OCTET STRINGread-onlymandatory
smTwoPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14OCTET STRINGread-onlymandatory
smTwoPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smTwoPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModThreePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3
smThreePortCfgTable
OBJECT-TYPE
Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1not-accessiblemandatory
smThreePortCfgEntry
OBJECT-TYPE
Switch Module 3 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1not-accessiblemandatory
smThreePortCfgIndex
OBJECT-TYPE
Switch Module 3 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1INTEGERread-onlymandatory
smThreePortCfgLabel
OBJECT-TYPE
Switch Module 3 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2OCTET STRINGread-onlymandatory
smThreePortCfgType
OBJECT-TYPE
Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smThreePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smThreePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smThreePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6OCTET STRINGread-writemandatory
smThreePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7OCTET STRINGread-onlymandatory
smThreePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8OCTET STRINGread-onlymandatory
smThreePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smThreePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smThreePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11INTEGERread-onlymandatory
smThreePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12INTEGERread-onlymandatory
smThreePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13OCTET STRINGread-onlymandatory
smThreePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14OCTET STRINGread-onlymandatory
smThreePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smThreePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModFourPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4
smFourPortCfgTable
OBJECT-TYPE
Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1not-accessiblemandatory
smFourPortCfgEntry
OBJECT-TYPE
Switch Module 4 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1not-accessiblemandatory
smFourPortCfgIndex
OBJECT-TYPE
Switch Module 4 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1INTEGERread-onlymandatory
smFourPortCfgLabel
OBJECT-TYPE
Switch Module 4 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2OCTET STRINGread-onlymandatory
smFourPortCfgType
OBJECT-TYPE
Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smFourPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smFourPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smFourPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6OCTET STRINGread-writemandatory
smFourPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7OCTET STRINGread-onlymandatory
smFourPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8OCTET STRINGread-onlymandatory
smFourPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smFourPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smFourPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11INTEGERread-onlymandatory
smFourPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12INTEGERread-onlymandatory
smFourPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13OCTET STRINGread-onlymandatory
smFourPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14OCTET STRINGread-onlymandatory
smFourPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smFourPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModFivePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5
smFivePortCfgTable
OBJECT-TYPE
Switch Module 5 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1not-accessiblemandatory
smFivePortCfgEntry
OBJECT-TYPE
Switch Module 5 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1not-accessiblemandatory
smFivePortCfgIndex
OBJECT-TYPE
Switch Module 5 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.1INTEGERread-onlymandatory
smFivePortCfgLabel
OBJECT-TYPE
Switch Module 5 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.2OCTET STRINGread-onlymandatory
smFivePortCfgType
OBJECT-TYPE
Switch Module 5 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smFivePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smFivePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smFivePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFivePortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.6OCTET STRINGread-writemandatory
smFivePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.7OCTET STRINGread-onlymandatory
smFivePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 5. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.8OCTET STRINGread-onlymandatory
smFivePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smFivePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smFivePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.11INTEGERread-onlymandatory
smFivePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.12INTEGERread-onlymandatory
smFivePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.13OCTET STRINGread-onlymandatory
smFivePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.14OCTET STRINGread-onlymandatory
smFivePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smFivePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModSixPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6
smSixPortCfgTable
OBJECT-TYPE
Switch Module 6 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1not-accessiblemandatory
smSixPortCfgEntry
OBJECT-TYPE
Switch Module 6 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1not-accessiblemandatory
smSixPortCfgIndex
OBJECT-TYPE
Switch Module 6 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.1INTEGERread-onlymandatory
smSixPortCfgLabel
OBJECT-TYPE
Switch Module 6 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.2OCTET STRINGread-onlymandatory
smSixPortCfgType
OBJECT-TYPE
Switch Module 6 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smSixPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smSixPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smSixPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSixPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.6OCTET STRINGread-writemandatory
smSixPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.7OCTET STRINGread-onlymandatory
smSixPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 6. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.8OCTET STRINGread-onlymandatory
smSixPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smSixPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smSixPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.11INTEGERread-onlymandatory
smSixPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.12INTEGERread-onlymandatory
smSixPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.13OCTET STRINGread-onlymandatory
smSixPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.14OCTET STRINGread-onlymandatory
smSixPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smSixPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModSevenPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7
smSevenPortCfgTable
OBJECT-TYPE
Switch Module 7 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1not-accessiblemandatory
smSevenPortCfgEntry
OBJECT-TYPE
Switch Module 7 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1not-accessiblemandatory
smSevenPortCfgIndex
OBJECT-TYPE
Switch Module 7 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.1INTEGERread-onlymandatory
smSevenPortCfgLabel
OBJECT-TYPE
Switch Module 7 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.2OCTET STRINGread-onlymandatory
smSevenPortCfgType
OBJECT-TYPE
Switch Module 7 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smSevenPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smSevenPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smSevenPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSevenPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.6OCTET STRINGread-writemandatory
smSevenPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.7OCTET STRINGread-onlymandatory
smSevenPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 7. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.8OCTET STRINGread-onlymandatory
smSevenPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smSevenPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smSevenPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.11INTEGERread-onlymandatory
smSevenPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.12INTEGERread-onlymandatory
smSevenPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.13OCTET STRINGread-onlymandatory
smSevenPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.14OCTET STRINGread-onlymandatory
smSevenPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smSevenPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModEightPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8
smEightPortCfgTable
OBJECT-TYPE
Switch Module 8 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1not-accessiblemandatory
smEightPortCfgEntry
OBJECT-TYPE
Switch Module 8 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1not-accessiblemandatory
smEightPortCfgIndex
OBJECT-TYPE
Switch Module 8 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.1INTEGERread-onlymandatory
smEightPortCfgLabel
OBJECT-TYPE
Switch Module 8 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.2OCTET STRINGread-onlymandatory
smEightPortCfgType
OBJECT-TYPE
Switch Module 8 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smEightPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smEightPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smEightPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smEightPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.6OCTET STRINGread-writemandatory
smEightPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.7OCTET STRINGread-onlymandatory
smEightPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 8. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.8OCTET STRINGread-onlymandatory
smEightPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smEightPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smEightPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.11INTEGERread-onlymandatory
smEightPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.12INTEGERread-onlymandatory
smEightPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.13OCTET STRINGread-onlymandatory
smEightPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.14OCTET STRINGread-onlymandatory
smEightPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smEightPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModNinePortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9
smNinePortCfgTable
OBJECT-TYPE
Switch Module 9 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1not-accessiblemandatory
smNinePortCfgEntry
OBJECT-TYPE
Switch Module 9 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1not-accessiblemandatory
smNinePortCfgIndex
OBJECT-TYPE
Switch Module 9 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.1INTEGERread-onlymandatory
smNinePortCfgLabel
OBJECT-TYPE
Switch Module 9 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.2OCTET STRINGread-onlymandatory
smNinePortCfgType
OBJECT-TYPE
Switch Module 9 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smNinePortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smNinePortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smNinePortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smNinePortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.6OCTET STRINGread-writemandatory
smNinePortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.7OCTET STRINGread-onlymandatory
smNinePortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 9. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.8OCTET STRINGread-onlymandatory
smNinePortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smNinePortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smNinePortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.11INTEGERread-onlymandatory
smNinePortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.12INTEGERread-onlymandatory
smNinePortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.13OCTET STRINGread-onlymandatory
smNinePortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.14OCTET STRINGread-onlymandatory
smNinePortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smNinePortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
switchModTenPortCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10
smTenPortCfgTable
OBJECT-TYPE
Switch Module 10 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1not-accessiblemandatory
smTenPortCfgEntry
OBJECT-TYPE
Switch Module 10 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1not-accessiblemandatory
smTenPortCfgIndex
OBJECT-TYPE
Switch Module 10 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.1INTEGERread-onlymandatory
smTenPortCfgLabel
OBJECT-TYPE
Switch Module 10 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.2OCTET STRINGread-onlymandatory
smTenPortCfgType
OBJECT-TYPE
Switch Module 10 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.3INTEGER {unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11)}read-onlymandatory
smTenPortCfgLinkSetting
OBJECT-TYPE
Current port link setting for Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.4INTEGER {down(0), up(1)}read-writemandatory
smTenPortCfgLinkState
OBJECT-TYPE
Current port link state of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.5INTEGER {down(0), up(1), initialized(2)}read-onlymandatory
smTenPortCfgSpeedSetting
OBJECT-TYPE
Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTenPortCfgAvailSpeeds are applicable to setting this mib object.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.6OCTET STRINGread-writemandatory
smTenPortCfgSpeedStatus
OBJECT-TYPE
Current port speed of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.7OCTET STRINGread-onlymandatory
smTenPortCfgAvailSpeeds
OBJECT-TYPE
Available speed setting per port for Switch Module 10. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.8OCTET STRINGread-onlymandatory
smTenPortCfgMedia
OBJECT-TYPE
Port media type of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.9INTEGER {copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255)}read-onlymandatory
smTenPortCfgProtocol
OBJECT-TYPE
Port protocol of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.10INTEGER {ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255)}read-onlymandatory
smTenPortCfgWidth
OBJECT-TYPE
The width of the port in terms of how many combined cables are present for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.11INTEGERread-onlymandatory
smTenPortCfgCableLength
OBJECT-TYPE
The length (in meters) of the cable supported by this port for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.12INTEGERread-onlymandatory
smTenPortCfgCableType
OBJECT-TYPE
External cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.13OCTET STRINGread-onlymandatory
smTenPortCfgVendorName
OBJECT-TYPE
The cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.14OCTET STRINGread-onlymandatory
smTenPortCfgCompatibility
OBJECT-TYPE
Compatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.15INTEGER {incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255)}read-onlymandatory
smTenPortCfgDataRate
OBJECT-TYPE
Data rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.16INTEGER {sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255)}read-onlymandatory
raidControllerConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.3
raidControllerTable
OBJECT-TYPE
RAID Controller control table.
1.3.6.1.4.1.2.3.51.2.22.3.3.1not-accessiblemandatory
raidControllerEntry
OBJECT-TYPE
RAID Controller control table entry.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1not-accessiblemandatory
raidControllerIndex
OBJECT-TYPE
RAID Controller control table index. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.1INTEGERread-onlymandatory
raidControllerId
OBJECT-TYPE
The I/O Module numeric identifier for the SAS Controller Module. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.2INTEGER {module3(3), module4(4)}read-onlymandatory
raidControllerExists
OBJECT-TYPE
Indicates whether the I/O Module specified for the RAID Controller exists or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
raidControllerPowerState
OBJECT-TYPE
Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.4INTEGER {off(0), on(1), shutdownInProgress(2)}read-onlymandatory
raidControllerMACAddress
OBJECT-TYPE
The MAC address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.5OCTET STRINGread-onlymandatory
raidControllerSasID
OBJECT-TYPE
The hardware VPD SAS ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.6OCTET STRINGread-onlymandatory
raidControllerPingRequest
OBJECT-TYPE
Sends a ping to the current IP address of the RAID Controller network interface. This MIB object can not be set, if AMM grants I/O Module the Protected Mode permission and the module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.7INTEGERread-writemandatory
raidControllerNetworkCfg
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.3.3.2
rcCurrentIPInfoTable
OBJECT-TYPE
RAID Controller current IP table. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1not-accessiblemandatory
rcCurrentIPInfoEntry
OBJECT-TYPE
RAID Controller current IP table entry. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1not-accessiblemandatory
rcCurrentIPInfoIndex
OBJECT-TYPE
RAID Controller current IP table index. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.1INTEGERread-onlymandatory
rcCurrentIPInfoId
OBJECT-TYPE
The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.2INTEGER {module3(3), module4(4)}read-onlymandatory
rcCurrentIPInfoExists
OBJECT-TYPE
Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
rcCurrentIPInfoPowerState
OBJECT-TYPE
Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.4INTEGER {off(0), on(1), shutdownInProgress(2)}read-onlymandatory
rcCurrentIPAddr
OBJECT-TYPE
The current IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.5IpAddressread-onlymandatory
rcCurrentSubnetMask
OBJECT-TYPE
The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.6IpAddressread-onlymandatory
rcCurrentGateway
OBJECT-TYPE
The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.7IpAddressread-onlymandatory
rcCurrentIPConfigMethod
OBJECT-TYPE
The current IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.8INTEGER {unknown(0), static(1), dhcp(2)}read-onlymandatory
rcCurrentRaidedVlanId
OBJECT-TYPE
The current virtual LAN ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.9INTEGERread-onlymandatory
rcNewIPInfoTable
OBJECT-TYPE
RAID Controller new IP configuration table. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2not-accessiblemandatory
rcNewIPInfoEntry
OBJECT-TYPE
RAID Controller new IP configuration information table entry. This MIB object is for SAS Controller Modules only. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1not-accessiblemandatory
rcNewIPInfoIndex
OBJECT-TYPE
RAID Controller new IP configuration information index. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.1INTEGERread-onlymandatory
rcNewIPInfoId
OBJECT-TYPE
The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.2INTEGER {module3(3), module4(4)}read-onlymandatory
rcNewIPInfoExists
OBJECT-TYPE
Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.3INTEGER {false(0), true(1)}read-onlymandatory
rcNewIPInfoPowerState
OBJECT-TYPE
Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.4INTEGER {off(0), on(1), shutdownInProgress(2)}read-onlymandatory
rcNewIPAddr
OBJECT-TYPE
The new IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.5IpAddressread-writemandatory
rcNewSubnetMask
OBJECT-TYPE
The new subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.6IpAddressread-writemandatory
rcNewGateway
OBJECT-TYPE
The new IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.7IpAddressread-writemandatory
rcNewIPConfigMethod
OBJECT-TYPE
The new IP configuration method for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: The value 'DHCP' can not be used to set. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.8INTEGER {unknown(0), static(1), dhcp(2)}read-writemandatory
rcNewIPConfigEnableDisable
OBJECT-TYPE
A set command enables new IP configurations that have been defined. A get command indicates whether new IP configurations that have been enabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.11INTEGER {disable(0), enable(1)}read-writemandatory
chassisTopology
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.4
chassisResponseVersion
OBJECT-TYPE
Chassis response version.
1.3.6.1.4.1.2.3.51.2.22.4.1INTEGERread-onlymandatory
chassisFlags
OBJECT-TYPE
Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis.
1.3.6.1.4.1.2.3.51.2.22.4.2INTEGER {rackOrStandAlone(0), serverBlade(1)}read-onlymandatory
chassisName
OBJECT-TYPE
The name of the active MM as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.4.3OCTET STRINGread-onlymandatory
chassisNoOfFPsSupported
OBJECT-TYPE
Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.18INTEGERread-onlymandatory
chassisNoOfPBsSupported
OBJECT-TYPE
Number of processor blades (PBs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.19INTEGERread-onlymandatory
chassisNoOfSMsSupported
OBJECT-TYPE
Number of switch modules (SMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.20INTEGERread-onlymandatory
chassisNoOfMMsSupported
OBJECT-TYPE
Number of management modules (MMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.21INTEGERread-onlymandatory
chassisNoOfPMsSupported
OBJECT-TYPE
Number of power modules (PMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.22INTEGERread-onlymandatory
chassisNoOfMTsSupported
OBJECT-TYPE
Number of media trays (MTs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.23INTEGERread-onlymandatory
chassisNoOfBlowersSupported
OBJECT-TYPE
Number of blowers supported. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.24INTEGERread-onlymandatory
chassisPBsInstalled
OBJECT-TYPE
The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'.
1.3.6.1.4.1.2.3.51.2.22.4.25OCTET STRINGread-onlymandatory
chassisSMsInstalled
OBJECT-TYPE
The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT.
1.3.6.1.4.1.2.3.51.2.22.4.29OCTET STRINGread-onlymandatory
chassisMMsInstalled
OBJECT-TYPE
The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.30OCTET STRINGread-onlymandatory
chassisPMsInstalled
OBJECT-TYPE
The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'.
1.3.6.1.4.1.2.3.51.2.22.4.31OCTET STRINGread-onlymandatory
chassisMTInstalled
OBJECT-TYPE
Indicates whether at least one media tray (MT) is installed.
1.3.6.1.4.1.2.3.51.2.22.4.32INTEGER {no(0), yes(1)}read-onlymandatory
chassisBlowersInstalled
OBJECT-TYPE
The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.33OCTET STRINGread-onlymandatory
chassisActiveMM
OBJECT-TYPE
The active management module (MM).
1.3.6.1.4.1.2.3.51.2.22.4.34INTEGERread-onlymandatory
chassisKVMOwner
OBJECT-TYPE
The blade that currently owns the keyboard/video/monitor (KVM). 0 = the KVM devices are owned by the management module.
1.3.6.1.4.1.2.3.51.2.22.4.35INTEGERread-onlymandatory
chassisMediaTrayOwner
OBJECT-TYPE
The blade that currently owns the media tray. 0 = the media tray is owned by the management module.
1.3.6.1.4.1.2.3.51.2.22.4.36INTEGERread-onlymandatory
chassisFPsInstalled
OBJECT-TYPE
The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.37OCTET STRINGread-onlymandatory
chassisType
OBJECT-TYPE
The type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the bladeCenterOrBladeCenterH type. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.38INTEGER {bladeCenterOrBladeCenterH(97), bladeCenterTOrBladeCenterHT(98)}read-onlymandatory
chassisSubtype
OBJECT-TYPE
The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.39INTEGER {bladeCenterOrBladeCenterT(0), bladeCenterHOrBladeCenterHT(2), bladeCenterS(3), bladeCenterE(4), bladeCenterH(5), bladeCenterT(32), unknown(255)}read-onlymandatory
chassisNoOfFBsSupported
OBJECT-TYPE
Number of Front Bezel (FBs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.40INTEGERread-onlymandatory
chassisNoOfAPsSupported
OBJECT-TYPE
Number of Alarm Panel (APs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.41INTEGERread-onlymandatory
chassisNoOfNCsSupported
OBJECT-TYPE
Number of Network Clocks (NCs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.42INTEGERread-onlydeprecated
chassisNoOfMXsSupported
OBJECT-TYPE
Number of Multiplexer Expansion modules (MXs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.43INTEGERread-onlymandatory
chassisNoOfMMIsSupported
OBJECT-TYPE
Number of management module interposers (MMIs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.44INTEGERread-onlymandatory
chassisNoOfSMIsSupported
OBJECT-TYPE
Number of switch module interposers (SMIs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.45INTEGERread-onlymandatory
chassisNoOfFBsInstalled
OBJECT-TYPE
The return value of '1'indicates the front bezel is installed on the chassis. The value of '0' indicates the front bezel is not installed.
1.3.6.1.4.1.2.3.51.2.22.4.46OCTET STRINGread-onlymandatory
chassisNoOfAPsInstalled
OBJECT-TYPE
The return value of '1'indicates the alarm panel is installed on the chassis. The value of '0' indicates the alarm panel is not installed.
1.3.6.1.4.1.2.3.51.2.22.4.47OCTET STRINGread-onlymandatory
chassisNoOfNCsInstalled
OBJECT-TYPE
The network clock cards that are installed on the chassis. The network clock cards are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of network clock cards supported. If a network clock card is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a network clock card is installed in bays 1, and 2 network clock cards are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.48OCTET STRINGread-onlydeprecated
chassisNoOfMXsInstalled
OBJECT-TYPE
The Multiplexer Expansion Modules that are installed on the chassis. The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of Multiplexer Expansion Modules supported. If a Multiplexer Expansion Module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if Multiplexer Expansion Module is installed in bays 1, and 2 Multiplexer Expansion Modules are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.49OCTET STRINGread-onlymandatory
chassisNoOfMMIsInstalled
OBJECT-TYPE
The flex cables that are installed on the chassis. The flex cables are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of flex cables supported. If a flex cable is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if flex cable is installed in bays 1, and 2 flex cables are supported, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.50OCTET STRINGread-onlymandatory
chassisNoOfSMIsInstalled
OBJECT-TYPE
The interposers that are installed on the chassis. The interposers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of interposers supported. If an interposer is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if interposer is installed in bays 1, and 10 interposers are supported, the string would look like '1000000000'.
1.3.6.1.4.1.2.3.51.2.22.4.51OCTET STRINGread-onlymandatory
chassisNoOfMTsInstalled
OBJECT-TYPE
The media trays that are installed on the chassis. The media trays are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of media trays supported. If a media tray is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if media trays are installed in bays 1, and 2 media trays are, the string would look like '10'.
1.3.6.1.4.1.2.3.51.2.22.4.52OCTET STRINGread-onlymandatory
managementModule
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.5
mmStatusTable
OBJECT-TYPE
Table of the management module status. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.5.1not-accessiblemandatory
mmStatusEntry
OBJECT-TYPE
Management module status entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.5.1.1not-accessiblemandatory
mmStatusIndex
OBJECT-TYPE
Management module status index.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.1INTEGERread-onlymandatory
mmPresent
OBJECT-TYPE
Management module current status.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.2INTEGER {no(0), yes(1)}read-onlymandatory
mmExtIpAddress
OBJECT-TYPE
Management module external IP address. NOTE: The IPv6 addresses assigned to the AMM may be viewed with the extEthernetInterfaceIPv6 objects
1.3.6.1.4.1.2.3.51.2.22.5.1.1.3IpAddressread-onlymandatory
mmPrimary
OBJECT-TYPE
Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.4INTEGER {no(0), yes(1)}read-onlymandatory
mmHealthState
OBJECT-TYPE
The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.5INTEGER {unknown(0), good(1), warning(2), bad(3)}read-onlymandatory
storage
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.6
storageStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.6.1
storageStatusTable
OBJECT-TYPE
Table of the storage module status. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.22.6.1.1not-accessiblemandatory
storageStatusEntry
OBJECT-TYPE
Storage Module Status Table Entry.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1not-accessiblemandatory
storageStatusIndex
OBJECT-TYPE
Storage device status table index.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.1INTEGERread-onlymandatory
storageBayNumber
OBJECT-TYPE
Bay number of the Storage device.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.2OCTET STRINGread-onlymandatory
storageState
OBJECT-TYPE
Storage device state.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.3INTEGER {unknown(0), good(1), warning(2), critical(3), notAvailable(255)}read-onlymandatory
storageName
OBJECT-TYPE
The name of the storage device.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.4OCTET STRINGread-onlymandatory
storageConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.6.2
storageSwitchConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.6.2.1
storageSwitchZoneCfgTable
OBJECT-TYPE
Table of all the zone configurations stored on switch modules. For consistent results, view as a table and not as individual entries. Before activating a new zone configuration via the switchActiveZoneCfg object, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1not-accessiblemandatory
storageSwitchZoneCfgEntry
OBJECT-TYPE
Switch Module Zone Configuration Management Entry.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1not-accessiblemandatory
switchZoneCfgIndex
OBJECT-TYPE
Switch module zone configuration table index.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.1INTEGERread-onlymandatory
switchZoneCfgBayNumber
OBJECT-TYPE
The numeric switch bay number.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.2INTEGERread-onlymandatory
switchZoneCfgNumber
OBJECT-TYPE
The zone configuration number, also referred to as the configuration store number.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.3INTEGERread-onlymandatory
switchZoneCfgStatus
OBJECT-TYPE
The status of the zone configuration. Only one configuration is 'Active', others are in 'nonActive' status. When a zone configuration is active on a switch, the status may temporarily indicate pending(2) as it transitions from nonActive(0) to active (1).
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.4INTEGER {nonActive(0), active(1), pending(2)}read-onlymandatory
switchZoneCfgType
OBJECT-TYPE
The type of the zone configuration. Predefined are read-only static configurations, and userdefined are read-write configurations that can be created and modified using the Switch Configuration Manager application.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.5INTEGER {userdefined(1), predefined(2)}read-onlymandatory
switchZoneCfgName
OBJECT-TYPE
A short descriptive name for the zone configuration.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.6OCTET STRINGread-onlymandatory
switchZoneCfgDescription
OBJECT-TYPE
A detailed description for the zone configuration.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.7OCTET STRINGread-onlymandatory
switchZoneCfgDate
OBJECT-TYPE
The date the zone configuration was created.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.8OCTET STRINGread-onlymandatory
switchActiveZoneCfg
OBJECT-TYPE
An object used to activate a particular zone configuration. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.9INTEGER {execute(1)}read-writemandatory
storageSwitchActiveZoneCfgTable
OBJECT-TYPE
Table showing the zone configuration that is currently active on a given switch module. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2not-accessiblemandatory
storageSwitchActiveZoneCfgEntry
OBJECT-TYPE
Active zone configurations Entry.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1not-accessiblemandatory
activeZoneCfgIndex
OBJECT-TYPE
Active zone configurations table index.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.1INTEGERread-onlymandatory
activeZoneCfgBayNumber
OBJECT-TYPE
Bay number of the switch module where active zone configurations exist.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.2OCTET STRINGread-onlymandatory
activeZoneCfgNumberBySwitch
OBJECT-TYPE
The zone configuration number active on this SAS switch module as reported by the switch module. If this number differs from the value of the activeZoneCfgNumberByMM object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 253 = I/O module is discovering zone information. 254 = I/O Module is not powered on or in a fault state. 255 = notApplicable.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.3INTEGERread-onlymandatory
activeZoneCfgNumberByMM
OBJECT-TYPE
The zone configuration number active on this SAS switch module as known by the management module. If this number differs from the value of the activeZoneCfgNumberBySwitch object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 255 = notApplicable.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.4INTEGERread-onlymandatory
switchZoneCfgActivation
OBJECT-TYPE
This object provides a quick means of activating a valid zone configuration on all active SAS switches. The zone configuration to be activated is specified as the value of the SET and can be obtained from the switchZoneCfgNumber object. The zone configuration number is also referred to as the zone configuration store. Before activating a new zone configuration, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned. NOTE: Value returned for the GET command is meaningless for this MIB object. If any of the switches are not activated, an error response will be returned.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.3INTEGERread-writemandatory
firmwareInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.8
smFirmwareInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.8.1
smFirmwareInfoTable
OBJECT-TYPE
Switch Module firmware image information. This table is only applicable to modules that support multiple images
1.3.6.1.4.1.2.3.51.2.22.8.1.1not-accessiblemandatory
smFirmwareInfoEntry
OBJECT-TYPE
Switch Module firmware image information table entry
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1not-accessiblemandatory
smFirmwareInfoIndex
OBJECT-TYPE
Sequence index in the firmware table.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1INTEGERread-onlymandatory
smFirmwareInfoModIndex
OBJECT-TYPE
Switch Module number.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2INTEGERread-onlymandatory
smFirmwareInfoImageIndex
OBJECT-TYPE
Switch Module firmware image index.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3INTEGERread-onlymandatory
smFirmwareInfoImageName
OBJECT-TYPE
Switch Module firmware image name
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4OCTET STRINGread-writemandatory
firmwareUpdate
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.9
firmwareUpdateTarget
OBJECT-TYPE
Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error.
1.3.6.1.4.1.2.3.51.2.22.9.1INTEGER {managementModule(0), switchModule1(11), switchModule2(12), switchModule3(13), switchModule4(14), switchModule5(15), switchModule6(16), switchModule7(17), switchModule8(18), switchModule9(19), switchModule10(20), blade1(31), blade2(32), blade3(33), blade4(34), blade5(35), blade6(36), blade7(37), blade8(38), blade9(39), blade10(40), blade11(41), blade12(42), blade13(43), blade14(44), unknown(255)}read-writemandatory
firmwareUpdateTftpServer
OBJECT-TYPE
If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6]).
1.3.6.1.4.1.2.3.51.2.22.9.2OCTET STRING (SIZE(0..63))read-writemandatory
firmwareUpdateFileName
OBJECT-TYPE
File name of the firmware file.
1.3.6.1.4.1.2.3.51.2.22.9.3OCTET STRING (SIZE(0..254))read-writemandatory
firmwareUpdateStart
OBJECT-TYPE
Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the AMM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.9.4INTEGER {execute(1), execute-with-reboot(2), execute-nowait(3), execute-with-reboot-nowait(4)}read-writemandatory
firmwareUpdateStatus
OBJECT-TYPE
Get the status of the last firmware update which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.2.22.9.5OCTET STRINGread-onlymandatory
standbyFirmwareUpdateStatus
OBJECT-TYPE
Get the current status of the firmware update for the standby AMM. NOTE: This only applies to systems with a standby AMM.
1.3.6.1.4.1.2.3.51.2.22.9.6OCTET STRINGread-onlymandatory
firmwareImageNumber
OBJECT-TYPE
If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section.
1.3.6.1.4.1.2.3.51.2.22.9.7INTEGERread-writemandatory
firmwareActiveImage
OBJECT-TYPE
If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.9.8INTEGERread-writemandatory
firmwareUpdateServer
OBJECT-TYPE
Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: <protocol>://<userid:password>@<hostname:port>/<pathname> An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: CNETCMUS.pkt Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: <protocol>://<hostname>/<pathname>.
1.3.6.1.4.1.2.3.51.2.22.9.9OCTET STRING (SIZE(0..254))read-writemandatory
remoteChassis
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.10
remoteChassisTable
OBJECT-TYPE
Table of remote chassis information.
1.3.6.1.4.1.2.3.51.2.22.10.1not-accessiblemandatory
remoteChassisEntry
OBJECT-TYPE
Remote chassis entry
1.3.6.1.4.1.2.3.51.2.22.10.1.1not-accessiblemandatory
remoteChassisIndex
OBJECT-TYPE
Remote chassis discovery sequence index.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.1INTEGERread-onlymandatory
systemName
OBJECT-TYPE
System name for this discovery management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.2OCTET STRINGread-onlymandatory
systemStatus
OBJECT-TYPE
System status summary (chassis).
1.3.6.1.4.1.2.3.51.2.22.10.1.1.3INTEGER {critical(0), non-Critical(2), system-Level(4), unknown(9), noResponse(170), normal(255)}read-onlymandatory
mmType
OBJECT-TYPE
Service processor type.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.4OCTET STRINGread-onlymandatory
mmSerial
OBJECT-TYPE
Management module serial number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.5OCTET STRINGread-onlymandatory
mmFru
OBJECT-TYPE
Management module Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.6OCTET STRINGread-onlymandatory
mmIp
OBJECT-TYPE
The IPv4 compliant address of the management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.7OCTET STRINGread-writemandatory
chassisSerial
OBJECT-TYPE
Chassis serial number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.8OCTET STRINGread-onlymandatory
chassisFru
OBJECT-TYPE
Chassis Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.9OCTET STRINGread-onlymandatory
chassisMachineTypeMode
OBJECT-TYPE
Chassis machine type and model number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.10OCTET STRINGread-onlymandatory
chassisUuid
OBJECT-TYPE
Chassis unique identifier.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.11OCTET STRINGread-onlymandatory
firmwareVersion
OBJECT-TYPE
Firmware version of the discovery management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.12OCTET STRINGread-onlymandatory
ipStatus
OBJECT-TYPE
A flag to state if IPv4 and IPv6 are enabled
1.3.6.1.4.1.2.3.51.2.22.10.1.1.13INTEGER {ipv4(1), ipv6(2), both(3)}read-onlymandatory
ipv6Addresses
OBJECT-TYPE
The IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.14OCTET STRINGread-onlymandatory
chassisDiscovery
OBJECT-TYPE
Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.10.2INTEGER {execute(1)}read-writemandatory
fileManagement
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.11
fileTopology
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.11.1
currentDirectory
OBJECT-TYPE
Specifies the directory name for listing the requested files.
1.3.6.1.4.1.2.3.51.2.22.11.1.1OCTET STRINGread-writemandatory
fileDetailsTable
OBJECT-TYPE
A table of all the files in the specified directory. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.11.1.2not-accessiblemandatory
fileDetailsEntry
OBJECT-TYPE
File details entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1not-accessiblemandatory
fileIndex
OBJECT-TYPE
File sequence index.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1INTEGERread-onlymandatory
fileName
OBJECT-TYPE
File name.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2OCTET STRINGread-onlymandatory
fileLastUpdate
OBJECT-TYPE
Date of the latest file update.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3OCTET STRINGread-onlymandatory
fileSize
OBJECT-TYPE
File size in bytes.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4OCTET STRINGread-onlymandatory
fileManagementCmd
OBJECT-TYPE
This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.11.3OCTET STRINGread-writemandatory
fileSystemSpaceAvailable
OBJECT-TYPE
This field displays the available space of the AMM file system.
1.3.6.1.4.1.2.3.51.2.22.11.6OCTET STRINGread-onlymandatory
componentMonitors
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.22.37
componentMACAddressTable
OBJECT-TYPE
Table of MAC address VPD information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.11not-accessiblemandatory
componentMACAddressEntry
OBJECT-TYPE
Component MAC address table entry
1.3.6.1.4.1.2.3.51.2.22.37.11.1not-accessiblemandatory
componentMACAddressTopologyPath
OBJECT-TYPE
The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more <component>,<instance> pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card
1.3.6.1.4.1.2.3.51.2.22.37.11.1.1OCTET STRING (SIZE(0..100))read-onlymandatory
componentMACAddressIndex
OBJECT-TYPE
Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.2INTEGERread-onlymandatory
componentMACAddressName
OBJECT-TYPE
The name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.3OCTET STRINGread-onlymandatory
componentMACAddress
OBJECT-TYPE
The MAC address VPD value for this component and index. The value is a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.4OCTET STRINGread-onlymandatory
service
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23
serviceConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.1
debugEnable
OBJECT-TYPE
Disable/Enable AMM debugging with USB key by service personnel.
1.3.6.1.4.1.2.3.51.2.23.1.3INTEGER {disabled(0), enabled(1)}read-writedeprecated
bladeServiceData
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.3
bladeServiceDataTable
OBJECT-TYPE
Table of blade service data information.
1.3.6.1.4.1.2.3.51.2.23.3.1not-accessiblemandatory
bladeServiceDataEntry
OBJECT-TYPE
Blade service data entry
1.3.6.1.4.1.2.3.51.2.23.3.1.1not-accessiblemandatory
serviceDataIndex
OBJECT-TYPE
Blade service date index.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.1INTEGERread-onlymandatory
serviceDataBladeId
OBJECT-TYPE
The numeric blade ID.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.2INTEGER {blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14)}read-onlymandatory
serviceDataBladeExists
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.3INTEGER {false(0), true(1)}read-onlymandatory
serviceDataBladePowerState
OBJECT-TYPE
Indicates whether the blade specified is powered on or not. If the AMM is experiencing a communication problem with the blade, the state may be returned as unknown(255)
1.3.6.1.4.1.2.3.51.2.23.3.1.1.4INTEGER {off(0), on(1), standby(3), hibernate(4), unknown(255)}read-onlymandatory
serviceDataBladeName
OBJECT-TYPE
The name of the blade as a string.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.5OCTET STRINGread-onlymandatory
serviceDataBladeCapability
OBJECT-TYPE
Indicates whether the blade has the capability to trigger service data. NOTE: This Mib object is deprecated and no longer supported. Please see serviceDataBladeCapabilityMask OID
1.3.6.1.4.1.2.3.51.2.23.3.1.1.6INTEGERread-onlydeprecated
serviceDataDumpInitiate
OBJECT-TYPE
Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. Only one file can be moved to the'/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.7INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
serviceDataDumpRetrieve
OBJECT-TYPE
Retrieve a type of service data file from blade to AMM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. Only one file can be moved to the '/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.8INTEGER {processorDump(1), platformDump(2), partitionDump(3), serviceData(4)}read-writemandatory
serviceDataDumpCapabilityMask
OBJECT-TYPE
Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the AMM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the AMM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the AMM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the AMM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the AMM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the AMM
1.3.6.1.4.1.2.3.51.2.23.3.1.1.9OCTET STRINGread-onlymandatory
serviceDataDumpInProgress
OBJECT-TYPE
An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the AMM and where the dump file is transferred to the AMM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.10INTEGER {inProgress(1), notInProgress(2), unknown(255)}read-onlymandatory
bladeSystemReferenceCodes
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.3.3
bladeSysRefCodesTable
OBJECT-TYPE
Table of blade system reference codes.
1.3.6.1.4.1.2.3.51.2.23.3.3.1not-accessiblemandatory
bladeSysRefCodesEntry
OBJECT-TYPE
Boot sequence entry
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1not-accessiblemandatory
sysRefCodeIndex
OBJECT-TYPE
System reference codes index.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.1INTEGERread-onlymandatory
sysRefCodeBayNumber
OBJECT-TYPE
The bay number of the blade which has the system reference code.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.2OCTET STRINGread-onlymandatory
sysRefCodeSequence
OBJECT-TYPE
Indicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.3INTEGERread-onlymandatory
sysRefCode
OBJECT-TYPE
Unique ID and system reference code for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.4OCTET STRINGread-writemandatory
sysRefCodeTimestamp
OBJECT-TYPE
Timestamp of system reference code for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.5OCTET STRINGread-writemandatory
bladeSysRefCodesDetailsTable
OBJECT-TYPE
Table of details of blade system reference codes.
1.3.6.1.4.1.2.3.51.2.23.3.3.2not-accessiblemandatory
bladeSysRefCodesDetailsEntry
OBJECT-TYPE
Boot sequence entry
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1not-accessiblemandatory
sysRefCodeDetailIndex
OBJECT-TYPE
System reference codes index.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.1INTEGERread-onlymandatory
sysRefCodeDetailBayNumber
OBJECT-TYPE
The bay number of the blade which has the details of system reference code.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.2OCTET STRINGread-onlymandatory
sysRefCodeDetailSRCSequence
OBJECT-TYPE
A sequence of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.3INTEGERread-onlymandatory
sysRefCodeDetailSequence
OBJECT-TYPE
A sequence of the detailed information of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.4OCTET STRINGread-writemandatory
sysRefCodeDetailDataString
OBJECT-TYPE
Detailed information of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.5OCTET STRINGread-writemandatory
serviceAdvisor
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4
autoCallHomeSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.1
acceptLicenseAgreement
OBJECT-TYPE
Accept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If AMM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the IBM BladeCenter User's Guide. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed.
1.3.6.1.4.1.2.3.51.2.23.4.1.1INTEGER {disabled(0), enabled(1)}read-writemandatory
serviceAdvisorEnable
OBJECT-TYPE
Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled.
1.3.6.1.4.1.2.3.51.2.23.4.1.2INTEGER {disabled(0), enabled(1)}read-writemandatory
serviceSupportCenter
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.2
ibmSupportCenter
OBJECT-TYPE
The country code for the IBM Support Center. 2 character ISO country code.
1.3.6.1.4.1.2.3.51.2.23.4.2.1OCTET STRINGread-writemandatory
contactInformation
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.3
companyName
OBJECT-TYPE
The organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.1OCTET STRINGread-writemandatory
contactName
OBJECT-TYPE
The name of the contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.2OCTET STRINGread-writemandatory
phoneNumber
OBJECT-TYPE
The phone of the contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.3OCTET STRINGread-writemandatory
emailAddress
OBJECT-TYPE
The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.4OCTET STRINGread-writemandatory
address
OBJECT-TYPE
The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.5OCTET STRINGread-writemandatory
city
OBJECT-TYPE
The city of the machine location. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.6OCTET STRINGread-writemandatory
state
OBJECT-TYPE
The state of the machine location. 2-3 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.7OCTET STRINGread-writemandatory
postalCode
OBJECT-TYPE
The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.2.3.51.2.23.4.3.8OCTET STRINGread-writemandatory
phoneNumberExt
OBJECT-TYPE
The extension of the phone. 30 characters maximum.
1.3.6.1.4.1.2.3.51.2.23.4.3.10OCTET STRINGread-writemandatory
altContactName
OBJECT-TYPE
(Optional) The name of the alternate contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.11OCTET STRINGread-writemandatory
altPhoneNumber
OBJECT-TYPE
(Optional) The phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.12OCTET STRINGread-writemandatory
altPhoneNumberExt
OBJECT-TYPE
(Optional) The extension of the alternate phone. 30 characters maximum.
1.3.6.1.4.1.2.3.51.2.23.4.3.13OCTET STRINGread-writemandatory
altEmailAddress
OBJECT-TYPE
(Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.14OCTET STRINGread-writemandatory
machineLocPhone
OBJECT-TYPE
(Optional) The contact phone number of the machine location. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.15OCTET STRINGread-writemandatory
httpProxyConfig
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.4
httpProxyEnable
OBJECT-TYPE
Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not connected to the internet directly.
1.3.6.1.4.1.2.3.51.2.23.4.4.1INTEGER {disabled(0), enabled(1)}read-writemandatory
httpProxyLocation
OBJECT-TYPE
Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.2.3.51.2.23.4.4.2OCTET STRINGread-writemandatory
httpProxyPort
OBJECT-TYPE
The port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.2.3.51.2.23.4.4.3INTEGERread-writemandatory
httpProxyUserName
OBJECT-TYPE
User Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.4OCTET STRINGread-writemandatory
httpProxyPassword
OBJECT-TYPE
Password of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.5OCTET STRINGread-writemandatory
activityLogs
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.4.5
activityLogTable
OBJECT-TYPE
Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home.
1.3.6.1.4.1.2.3.51.2.23.4.5.1not-accessiblemandatory
activityLogEntry
OBJECT-TYPE
Activity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by IBM support, the event ID, event source, date and time that event occured, and a text message.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1not-accessiblemandatory
activityLogIndex
OBJECT-TYPE
The Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1INTEGERread-onlymandatory
activityLogString
OBJECT-TYPE
A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2OCTET STRINGread-onlymandatory
activityLogAcknowledge
OBJECT-TYPE
The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at IBM support. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via IBM Support or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3INTEGER {no(0), yes(1)}read-writemandatory
activityLogAttribute
OBJECT-TYPE
A string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to IBM support or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling IBM Support or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting IBM support. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4OCTET STRINGread-onlymandatory
autoFTPSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.5
autoFTPCallMode
OBJECT-TYPE
This field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component.
1.3.6.1.4.1.2.3.51.2.23.5.1INTEGER {disabled(0), ftp(1), tftp(2)}read-writemandatory
autoFTPCallAddr
OBJECT-TYPE
This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.2.3.51.2.23.5.2OCTET STRINGread-writemandatory
autoFTPCallPort
OBJECT-TYPE
This field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.2.3.51.2.23.5.3INTEGERread-writemandatory
autoFTPCallUserID
OBJECT-TYPE
This field specifies the user account to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.4OCTET STRINGread-writemandatory
autoFTPCallPassword
OBJECT-TYPE
This field specifies the password to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.5OCTET STRINGread-writemandatory
callHomeExclusionEvents
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.23.6
readCallHomeExclusionEventTable
OBJECT-TYPE
Table of Call Home Exclusion Event entries information.
1.3.6.1.4.1.2.3.51.2.23.6.1not-accessiblemandatory
readCallHomeExclusionEventEntry
OBJECT-TYPE
Call Home Exclusion Event table entry
1.3.6.1.4.1.2.3.51.2.23.6.1.1not-accessiblemandatory
readCallHomeExclusionEventIndex
OBJECT-TYPE
The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.1INTEGERread-onlymandatory
readCallHomeExclusionEventID
OBJECT-TYPE
The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.2OCTET STRINGread-onlymandatory
addCallHomeExclusionEvent
OBJECT-TYPE
Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.2OCTET STRINGread-writemandatory
rmCallHomeExclusionEvent
OBJECT-TYPE
Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.3OCTET STRINGread-writemandatory
rmAllCallHomeExclusionEvent
OBJECT-TYPE
Remove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.23.6.4INTEGER {execute(1)}read-writemandatory
scaling
OBJECT-IDENTITY
1.3.6.1.4.1.2.3.51.2.24
scalableComplexTable
OBJECT-TYPE
Table of scalable complex information. This table provides information and control actions related to the scalable complexes installed in the chassis. Partition, node and port information and control are defined in their own tables.
1.3.6.1.4.1.2.3.51.2.24.1not-accessiblemandatory
scalableComplexEntry
OBJECT-TYPE
Scalable complex information.
1.3.6.1.4.1.2.3.51.2.24.1.1not-accessiblemandatory
scalableComplexIdentifier
OBJECT-TYPE
The unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1.1.1INTEGERread-onlymandatory
scalableComplexNumPartitions
OBJECT-TYPE
The number of partitions currently defined for this complex.
1.3.6.1.4.1.2.3.51.2.24.1.1.2INTEGERread-onlymandatory
scalableComplexNumNodes
OBJECT-TYPE
The number of nodes existing in this complex, regardless of their assignment to any given partition. The physical slot location of the nodes can be determined from the scalableComplexNodeTable.
1.3.6.1.4.1.2.3.51.2.24.1.1.3INTEGERread-onlymandatory
scalableComplexPartStartSlot
OBJECT-TYPE
The lowest slot number occupied by the nodes in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation.
1.3.6.1.4.1.2.3.51.2.24.1.1.4INTEGERread-writemandatory
scalableComplexPartNumNodes
OBJECT-TYPE
The number of nodes to be included in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation.
1.3.6.1.4.1.2.3.51.2.24.1.1.5INTEGERread-writemandatory
scalableComplexAction
OBJECT-TYPE
This object allows various actions to be taken in relation to a particular complex. clear(1) - This clears all partition information related to the complex. Any nodes associated with the complex are no longer assigned to any partitions. All nodes in the complex must be powered off prior to attempting this operation, otherwise, the action will fail. autocreate(2) - This creates a single partition which includes all nodes associated with the complex. Any other prior partition definitions must be deleted prior to issuing this action, otherwise, the action will fail. create(3) - This allows the creation of a partition within the complex. Prior to triggering this action, the scalableComplexPartStartSlot and scalableComplexPartNumNodes objects must be set first to identify the starting slot number and number of nodes to be included in this new partition. The nodes chosen for inclusion in this new partition must not be part of another existing partition, otherwise, the action will fail.
1.3.6.1.4.1.2.3.51.2.24.1.1.6INTEGER {clear(1), autocreate(2), create(3)}write-onlymandatory
scalableComplexPartitionTable
OBJECT-TYPE
Table of scalable complex partition information. This table provides information and control actions related to the partitions defined across all of the complexes installed in the chassis. Complex, node and port information and control are defined in their own tables.
1.3.6.1.4.1.2.3.51.2.24.2not-accessiblemandatory
scalableComplexPartitionEntry
OBJECT-TYPE
Scalable complex partition information.
1.3.6.1.4.1.2.3.51.2.24.2.1not-accessiblemandatory
scalableComplexId
OBJECT-TYPE
The unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.2.1.1INTEGERread-onlymandatory
scalableComplexPartitionIdentifier
OBJECT-TYPE
The unique numeric identifier for a partition defined within a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.2.1.2INTEGERread-onlymandatory
scalableComplexPartitionMode
OBJECT-TYPE
The currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a partition mode to stand-alone will cause subsequent partition actions to be ignored until the partition mode is restored.
1.3.6.1.4.1.2.3.51.2.24.2.1.3INTEGER {partition(1), standalone(2)}read-writemandatory
scalableComplexPartitionNumNodes
OBJECT-TYPE
The number of nodes currently defined for this partition.
1.3.6.1.4.1.2.3.51.2.24.2.1.4INTEGERread-onlymandatory
scalableComplexPartitionStatus
OBJECT-TYPE
The current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition consitency check problem, the invalid state is provided.
1.3.6.1.4.1.2.3.51.2.24.2.1.5INTEGER {poweredoff(1), poweredon(2), resetting(3), invalid(4)}read-onlymandatory
scalableComplexPartitionAction
OBJECT-TYPE
This object allows various actions to be taken in relation to a particular partition in a given complex. delete(1) - Deletes the partition from the complex. All nodes in the partition must be powered off prior to attempting this operation, otherwise, the action will fail. poweron(2) - Powers up a powered off partition poweroff(3) - Powers off an already powered on partition powercycle(4) - Power cycles a partition
1.3.6.1.4.1.2.3.51.2.24.2.1.6INTEGER {delete(1), poweron(2), poweroff(3), powercycle(4)}write-onlymandatory
scalableComplexNodeTable
OBJECT-TYPE
Table of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partition and port information and control are defined in their own tables.
1.3.6.1.4.1.2.3.51.2.24.3not-accessiblemandatory
scalableComplexNodeEntry
OBJECT-TYPE
Scalable complex node information.
1.3.6.1.4.1.2.3.51.2.24.3.1not-accessiblemandatory
scalableComplexNodeSlot
OBJECT-TYPE
The base slot number where the node exists in the chassis.
1.3.6.1.4.1.2.3.51.2.24.3.1.1INTEGERread-onlymandatory
scalableComplexNodeName
OBJECT-TYPE
The description string which uniquely identifies the blade.
1.3.6.1.4.1.2.3.51.2.24.3.1.2OCTET STRING (SIZE(256))read-onlymandatory
scalableComplexNodeType
OBJECT-TYPE
The general categorization of the node.
1.3.6.1.4.1.2.3.51.2.24.3.1.3INTEGER {processor(1), memory(2), io(3)}read-onlymandatory
scalableComplexNodeResources
OBJECT-TYPE
A string providing a summary overview of the resources provided by this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.4OCTET STRING (SIZE(256))read-onlymandatory
scalableComplexNodeRole
OBJECT-TYPE
Indicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not.
1.3.6.1.4.1.2.3.51.2.24.3.1.5INTEGER {primary(1), secondary(2), unassigned(255)}read-onlymandatory
scalableComplexNodeState
OBJECT-TYPE
The physical power state of this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.6INTEGER {poweredoff(1), poweredon(2), resetting(3)}read-onlymandatory
scalableComplexNodeUUID
OBJECT-TYPE
The Universally Unique IDentifier (UUID) of this node, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.24.3.1.7OCTET STRING (SIZE(256))read-onlymandatory
scalableComplexNodeSerialNum
OBJECT-TYPE
The serial number of this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.8OCTET STRING (SIZE(256))read-onlymandatory
scalableComplexNodeNumPorts
OBJECT-TYPE
The number of remote nodes that this node has links to.
1.3.6.1.4.1.2.3.51.2.24.3.1.9INTEGERread-onlymandatory
scalableComplexNodeComplexID
OBJECT-TYPE
For an assigned node, the identifier of the complex this node is related to. For an unassigned node, this object has no meaning.
1.3.6.1.4.1.2.3.51.2.24.3.1.10INTEGERread-onlymandatory
scalableComplexNodePartitionID
OBJECT-TYPE
For an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning.
1.3.6.1.4.1.2.3.51.2.24.3.1.11INTEGERread-onlymandatory
scalableComplexNodeLogicalID
OBJECT-TYPE
The unique numeric identifier for this node, unique within the partition.
1.3.6.1.4.1.2.3.51.2.24.3.1.12INTEGERread-onlymandatory
scalableComplexNodeAction
OBJECT-TYPE
The actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object.
1.3.6.1.4.1.2.3.51.2.24.3.1.14INTEGER {poweroff(1), poweron(2)}write-onlymandatory
scalableComplexNodePortTable
OBJECT-TYPE
Table of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control are defined in their own tables.
1.3.6.1.4.1.2.3.51.2.24.4not-accessiblemandatory
scalableComplexNodePortEntry
OBJECT-TYPE
Scalable complex node port information.
1.3.6.1.4.1.2.3.51.2.24.4.1not-accessiblemandatory
scalableComplexNodePortSlot
OBJECT-TYPE
The base slot number where the node exists in the chassis.
1.3.6.1.4.1.2.3.51.2.24.4.1.1INTEGERread-onlymandatory
scalableComplexNodePortNum
OBJECT-TYPE
The port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented as one more than the actual port number.
1.3.6.1.4.1.2.3.51.2.24.4.1.2INTEGERread-onlymandatory
scalableComplexNodePortRemChkSum
OBJECT-TYPE
The checksum of the remote port, used as a port identifier.
1.3.6.1.4.1.2.3.51.2.24.4.1.3INTEGERread-onlymandatory
scalableComplexNodePortRemNum
OBJECT-TYPE
The zero-based port number of the remote port.
1.3.6.1.4.1.2.3.51.2.24.4.1.4INTEGERread-onlymandatory
scalableComplexNodePortStatus
OBJECT-TYPE
The current status of the port.
1.3.6.1.4.1.2.3.51.2.24.4.1.5INTEGER {disabled(1), enabled(2), unknown(255)}read-onlymandatory
scalableComplexNodePortType
OBJECT-TYPE
The port type.
1.3.6.1.4.1.2.3.51.2.24.4.1.6INTEGER {qpi(1), exa(2), unknown(255)}read-onlymandatory