BKTEL-HFC862-OA-V01-MIB
- Registered at
- 1.3.6.1.4.1.7501.1.2.116
- Namespace
- bktel
- Source file
BKTEL-HFC862-OA-V01-MIB- Digest
sha256:eeb29a7f1dc1854b40cdbd5e06afc003220d221ecf5660b2040e86fa2bdc5920
Imports
| From | Symbols |
|---|---|
| BKTEL-HFC862-BASE-MIB | DisplayString, ModuleWidthValue, NESlotValue, PerceivedSeverityValue, TruthValue, modules |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BKTEL-HFC862-BASE-MIB BKTEL-HFC862-OA-V01-MIB RFC1155-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ExtIOmask type | ||||
| ExtIOmode type | ||||
| LaserFeatures type | ||||
| NESlotWriteValue type | ||||
| RegulationMode type | ||||
| SbsEvaluationMode type | ||||
| SbsEvaluationState type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| oa OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116 | |||
| oaCommon OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.1 | |||
| oaCommonNumberOfModules OBJECT-TYPE Number of modules in table. | 1.3.6.1.4.1.7501.1.2.116.1.1 | INTEGER (0..50) | read-only | mandatory |
| oaCommonTable OBJECT-TYPE The table contains all modules of the OA-type in the NE | 1.3.6.1.4.1.7501.1.2.116.1.2 | not-accessible | mandatory | |
| oaCommonEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.116.1.2.1 | not-accessible | mandatory | |
| oaNESlot OBJECT-TYPE The slot number of the chassis for which this entry contains management information. | 1.3.6.1.4.1.7501.1.2.116.1.2.1.1 | NESlotValue | read-only | mandatory |
| oaCommonType OBJECT-TYPE The type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown. | 1.3.6.1.4.1.7501.1.2.116.1.2.1.2 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| oaCommonDescr OBJECT-TYPE A textual description of the module. If not available, this Value should be set to a zero length string. | 1.3.6.1.4.1.7501.1.2.116.1.2.1.3 | DisplayString | read-write | mandatory |
| oaCommonFirmwareId OBJECT-TYPE The firmware Id of the module. | 1.3.6.1.4.1.7501.1.2.116.1.2.1.4 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| oaCommonModuleWidth OBJECT-TYPE The width of the module in multiples of slots (1, 2, ...) | 1.3.6.1.4.1.7501.1.2.116.1.2.1.5 | ModuleWidthValue | read-only | optional |
| oaStates OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.2 | |||
| oaStatesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.2.1 | not-accessible | mandatory | |
| oaStatesEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.116.2.1.1 | not-accessible | mandatory | |
| oaStatesBootloader OBJECT-TYPE The device is running in bootloader mode without a legal application software. | 1.3.6.1.4.1.7501.1.2.116.2.1.1.1 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesCommLoss OBJECT-TYPE The NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device | 1.3.6.1.4.1.7501.1.2.116.2.1.1.2 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInitializing OBJECT-TYPE The device is initializing | 1.3.6.1.4.1.7501.1.2.116.2.1.1.3 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserShutdown OBJECT-TYPE Lasers are shutdown, no optical output | 1.3.6.1.4.1.7501.1.2.116.2.1.1.4 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesTemperatureLow OBJECT-TYPE Device internal temperature low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.5 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesTemperatureHigh OBJECT-TYPE Device internal temperature high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.6 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesSystem OBJECT-TYPE Internal error occured | 1.3.6.1.4.1.7501.1.2.116.2.1.1.7 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInputPwrLow OBJECT-TYPE Optical input power low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.8 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInputPwrHigh OBJECT-TYPE Optical input power high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.9 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesOutputPwrOrGainLow OBJECT-TYPE Optical output power (or gain) low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.10 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesOutputPwrOrGainHigh OBJECT-TYPE Optical output power (or gain) high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.11 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesReturnLossLow OBJECT-TYPE Return loss low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.12 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesReturnLossHigh OBJECT-TYPE Return loss high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.13 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesRedundancySwitch OBJECT-TYPE This (redundant) device has been activated (redundancy switchover) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.14 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInputVoltageLow OBJECT-TYPE Input supply voltage low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.15 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInputVoltageHigh OBJECT-TYPE Input supply voltage high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.16 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesPowerSupplyLeft OBJECT-TYPE The left (looking from front) power supply unit fails. Only valid for devices in 19 inch housing | 1.3.6.1.4.1.7501.1.2.116.2.1.1.25 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesPowerSupplyRight OBJECT-TYPE The right (looking from front) power supply unit fails. Only valid for devices in 19 inch housing | 1.3.6.1.4.1.7501.1.2.116.2.1.1.26 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesFanLeft OBJECT-TYPE The left (looking from front) fan unit fails. Only valid for devices in 19 inch housing | 1.3.6.1.4.1.7501.1.2.116.2.1.1.27 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesFanRight OBJECT-TYPE The right (looking from front) fan unit fails. Only valid for devices in 19 inch housing | 1.3.6.1.4.1.7501.1.2.116.2.1.1.28 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInternalVoltageLow OBJECT-TYPE One (or more) internal voltages low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.29 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesInternalVoltageHigh OBJECT-TYPE One (or more) internal voltages high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.30 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserCurrentLow OBJECT-TYPE Laser current of one (or more) lasers low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.31 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserCurrentHigh OBJECT-TYPE Laser current of one (or more) lasers high (laser is aging) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.32 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesTecCurrentLow OBJECT-TYPE Laser TEC current limit of one (or more) lasers reached (heating limit) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.33 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesTecCurrentHigh OBJECT-TYPE Laser TEC current limit of one (or more) lasers reached (cooling limit) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.34 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserTempLow OBJECT-TYPE Laser temperature of one (or more) lasers low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.35 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserTempHigh OBJECT-TYPE Laser temperature of one (or more) lasers high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.36 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserVoltageLow OBJECT-TYPE Laser voltage supply of one (or more) lasers low | 1.3.6.1.4.1.7501.1.2.116.2.1.1.37 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesLaserVoltageHigh OBJECT-TYPE Laser voltage supply of one (or more) lasers high | 1.3.6.1.4.1.7501.1.2.116.2.1.1.38 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesRamanBackReflectionRatio OBJECT-TYPE Raman amplifier back reflection ratio high alarm Only used if oaDisplayAmplifierIsRamanType == true(1) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.39 | PerceivedSeverityValue | read-only | mandatory |
| oaStatesRamanOscSignalMissing OBJECT-TYPE Raman amplifier oscillator signal missing alarm Only used if oaDisplayAmplifierIsRamanType == true(1) | 1.3.6.1.4.1.7501.1.2.116.2.1.1.40 | PerceivedSeverityValue | read-only | mandatory |
| oaConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.3 | |||
| oaConfigurationTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.3.1 | not-accessible | mandatory | |
| oaConfigurationEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.3.1.1 | not-accessible | mandatory | |
| oaConfigNESlotWrite OBJECT-TYPE By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable. | 1.3.6.1.4.1.7501.1.2.116.3.1.1.1 | NESlotWriteValue | read-write | optional |
| oaConfigRegulationMode OBJECT-TYPE The regulation mode of the device. - regModeConstantOutputPower(1): If the device runs in constant output power mode, then all *OutputPwrOrGain* variables are interpreted as 'Output Power' specific. - regModeConstantGain(2): If the device runs in constant gain mode, then all *OutputPwrOrGain* variables are interpreted as 'Gain' specific. | 1.3.6.1.4.1.7501.1.2.116.3.1.1.2 | RegulationMode | read-write | mandatory |
| oaConfigOutputPwrOrGainAdjust OBJECT-TYPE This variable can be used to adjust the desired output power (or gain) value in 0.1 dB units relative to its nominal level. See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.3.1.1.3 | INTEGER | read-write | mandatory |
| oaConfigModeExtIO OBJECT-TYPE The mode and usage of the device's external IO port. | 1.3.6.1.4.1.7501.1.2.116.3.1.1.4 | ExtIOmode | read-write | mandatory |
| oaConfigMaskExtIO OBJECT-TYPE The alarm/warning mask that activates the device's external IO port. | 1.3.6.1.4.1.7501.1.2.116.3.1.1.5 | ExtIOmask | read-write | mandatory |
| oaConfigSbsEvaluationMode OBJECT-TYPE The SBS threshold evaluation mode. | 1.3.6.1.4.1.7501.1.2.116.3.1.1.6 | SbsEvaluationMode | read-write | mandatory |
| oaControl OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.4 | |||
| oaControlTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.4.1 | not-accessible | mandatory | |
| oaControlEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.116.4.1.1 | not-accessible | mandatory | |
| oaControlLaserShutdown OBJECT-TYPE Shutdown the laser(s), optical power on/off. | 1.3.6.1.4.1.7501.1.2.116.4.1.1.1 | TruthValue | read-write | mandatory |
| oaControlReset OBJECT-TYPE Reset the module. | 1.3.6.1.4.1.7501.1.2.116.4.1.1.2 | TruthValue | read-write | mandatory |
| oaControlModuleLedBlink OBJECT-TYPE Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variable always returns false(2) on read requests | 1.3.6.1.4.1.7501.1.2.116.4.1.1.3 | TruthValue | read-write | mandatory |
| oaControlSbsEvaluationStart OBJECT-TYPE Setting to true(1) starts an SBS threshold evaluation process. Always reads as false(2) | 1.3.6.1.4.1.7501.1.2.116.4.1.1.4 | TruthValue | read-write | mandatory |
| oaMeasuringValues OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.5 | |||
| oaMeasuringValuesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.5.1 | not-accessible | mandatory | |
| oaMeasuringValuesEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.116.5.1.1 | not-accessible | mandatory | |
| oaTemperatureLoLo OBJECT-TYPE The module temperature low alarm threshold in steps of 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.1 | INTEGER | read-only | mandatory |
| oaTemperatureLo OBJECT-TYPE The module temperature low warning threshold in steps of 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.2 | INTEGER | read-only | mandatory |
| oaTemperatureValue OBJECT-TYPE The module temperature in steps of 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.3 | INTEGER | read-only | mandatory |
| oaTemperatureHi OBJECT-TYPE The module temperature high warning threshold in steps of 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.4 | INTEGER | read-only | mandatory |
| oaTemperatureHiHi OBJECT-TYPE The module temperature high alarm threshold in steps of 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.5 | INTEGER | read-only | mandatory |
| oaInputPowerLoLo OBJECT-TYPE Input power low alarm threshold in steps of 0.1dBm. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.6 | INTEGER | read-write | mandatory |
| oaInputPowerLo OBJECT-TYPE Input power low warning threshold in steps of 0.1dBm. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.7 | INTEGER | read-write | mandatory |
| oaInputPowerValue OBJECT-TYPE Input power in steps of 0.1dBm. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.8 | INTEGER | read-only | mandatory |
| oaInputPowerHi OBJECT-TYPE Input power high warning threshold in steps of 0.1dBm. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.9 | INTEGER | read-write | mandatory |
| oaInputPowerHiHi OBJECT-TYPE Input power high alarm threshold in steps of 0.1dBm. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.10 | INTEGER | read-write | mandatory |
| oaOutputPwrOrGainLoLo OBJECT-TYPE Output power (or gain) low alarm threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.5.1.1.11 | INTEGER | read-write | mandatory |
| oaOutputPwrOrGainLo OBJECT-TYPE Output power (or gain) low warning threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.5.1.1.12 | INTEGER | read-write | mandatory |
| oaOutputPwrOrGainValue OBJECT-TYPE Output power (or gain) in steps of 0.1dB(m). See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.5.1.1.13 | INTEGER | read-only | mandatory |
| oaOutputPwrOrGainHi OBJECT-TYPE Output power (or gain) high warning threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.5.1.1.14 | INTEGER | read-write | mandatory |
| oaOutputPwrOrGainHiHi OBJECT-TYPE Output power (or gain) high alarm threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.5.1.1.15 | INTEGER | read-write | mandatory |
| oaReturnLossLoLo OBJECT-TYPE ReturnLoss low alarm threshold in steps of 0.1 dB. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.16 | INTEGER | read-write | mandatory |
| oaReturnLossLo OBJECT-TYPE ReturnLoss low warning threshold in steps of 0.1 dB. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.17 | INTEGER | read-write | mandatory |
| oaReturnLossValue OBJECT-TYPE ReturnLoss in steps of 0.1 dB. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.18 | INTEGER | read-only | mandatory |
| oaReturnLossHi OBJECT-TYPE ReturnLoss high warning threshold in steps of 0.1 dB. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.19 | INTEGER | read-write | mandatory |
| oaReturnLossHiHi OBJECT-TYPE ReturnLoss high alarm threshold in steps of 0.1 dB. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.20 | INTEGER | read-write | mandatory |
| oaInputVoltageLoLo OBJECT-TYPE The input supply voltage low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.21 | INTEGER | read-only | mandatory |
| oaInputVoltageLo OBJECT-TYPE The input supply voltage low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.22 | INTEGER | read-only | mandatory |
| oaInputVoltageValue OBJECT-TYPE The input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'oaDisplayInputVoltageNominal' | 1.3.6.1.4.1.7501.1.2.116.5.1.1.23 | INTEGER | read-only | mandatory |
| oaInputVoltageHi OBJECT-TYPE The input supply voltage high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.24 | INTEGER | read-only | mandatory |
| oaInputVoltageHiHi OBJECT-TYPE The input supply voltage high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.25 | INTEGER | read-only | mandatory |
| oaInternalVoltage1LoLo OBJECT-TYPE The internal voltage low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.46 | INTEGER | read-only | optional |
| oaInternalVoltage1Lo OBJECT-TYPE The internal voltage low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.47 | INTEGER | read-only | optional |
| oaInternalVoltage1Value OBJECT-TYPE The internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage1Nominal' | 1.3.6.1.4.1.7501.1.2.116.5.1.1.48 | INTEGER | read-only | optional |
| oaInternalVoltage1Hi OBJECT-TYPE The internal voltage high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.49 | INTEGER | read-only | optional |
| oaInternalVoltage1HiHi OBJECT-TYPE The internal voltage high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.50 | INTEGER | read-only | optional |
| oaInternalVoltage2LoLo OBJECT-TYPE The internal voltage low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.51 | INTEGER | read-only | optional |
| oaInternalVoltage2Lo OBJECT-TYPE The internal voltage low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.52 | INTEGER | read-only | optional |
| oaInternalVoltage2Value OBJECT-TYPE The internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage2Nominal' | 1.3.6.1.4.1.7501.1.2.116.5.1.1.53 | INTEGER | read-only | optional |
| oaInternalVoltage2Hi OBJECT-TYPE The internal voltage high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.54 | INTEGER | read-only | optional |
| oaInternalVoltage2HiHi OBJECT-TYPE The internal voltage high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.55 | INTEGER | read-only | optional |
| oaInternalVoltage3LoLo OBJECT-TYPE The internal voltage low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.56 | INTEGER | read-only | optional |
| oaInternalVoltage3Lo OBJECT-TYPE The internal voltage low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.57 | INTEGER | read-only | optional |
| oaInternalVoltage3Value OBJECT-TYPE The internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage3Nominal' | 1.3.6.1.4.1.7501.1.2.116.5.1.1.58 | INTEGER | read-only | optional |
| oaInternalVoltage3Hi OBJECT-TYPE The internal voltage high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.59 | INTEGER | read-only | optional |
| oaInternalVoltage3HiHi OBJECT-TYPE The internal voltage high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.60 | INTEGER | read-only | optional |
| oaLaser1CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.86 | INTEGER | read-only | mandatory |
| oaLaser1CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.87 | INTEGER | read-only | mandatory |
| oaLaser1CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.88 | INTEGER | read-only | mandatory |
| oaLaser1CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.89 | INTEGER | read-only | mandatory |
| oaLaser1CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.90 | INTEGER | read-only | mandatory |
| oaLaser1TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.91 | INTEGER | read-only | mandatory |
| oaLaser1TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.92 | INTEGER | read-only | mandatory |
| oaLaser1TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.93 | INTEGER | read-only | mandatory |
| oaLaser1TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.94 | INTEGER | read-only | mandatory |
| oaLaser1TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.95 | INTEGER | read-only | mandatory |
| oaLaser1TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.96 | INTEGER | read-only | mandatory |
| oaLaser1TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.97 | INTEGER | read-only | mandatory |
| oaLaser1TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.98 | INTEGER | read-only | mandatory |
| oaLaser1TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.99 | INTEGER | read-only | mandatory |
| oaLaser1TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.100 | INTEGER | read-only | mandatory |
| oaLaser1VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.101 | INTEGER | read-only | optional |
| oaLaser1VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.102 | INTEGER | read-only | optional |
| oaLaser1VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.103 | INTEGER | read-only | optional |
| oaLaser1VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.104 | INTEGER | read-only | optional |
| oaLaser1VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.105 | INTEGER | read-only | optional |
| oaLaser2CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.111 | INTEGER | read-only | mandatory |
| oaLaser2CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.112 | INTEGER | read-only | mandatory |
| oaLaser2CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.113 | INTEGER | read-only | mandatory |
| oaLaser2CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.114 | INTEGER | read-only | mandatory |
| oaLaser2CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.115 | INTEGER | read-only | mandatory |
| oaLaser2TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.116 | INTEGER | read-only | mandatory |
| oaLaser2TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.117 | INTEGER | read-only | mandatory |
| oaLaser2TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.118 | INTEGER | read-only | mandatory |
| oaLaser2TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.119 | INTEGER | read-only | mandatory |
| oaLaser2TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.120 | INTEGER | read-only | mandatory |
| oaLaser2TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.121 | INTEGER | read-only | mandatory |
| oaLaser2TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.122 | INTEGER | read-only | mandatory |
| oaLaser2TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.123 | INTEGER | read-only | mandatory |
| oaLaser2TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.124 | INTEGER | read-only | mandatory |
| oaLaser2TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.125 | INTEGER | read-only | mandatory |
| oaLaser2VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.126 | INTEGER | read-only | optional |
| oaLaser2VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.127 | INTEGER | read-only | optional |
| oaLaser2VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.128 | INTEGER | read-only | optional |
| oaLaser2VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.129 | INTEGER | read-only | optional |
| oaLaser2VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.130 | INTEGER | read-only | optional |
| oaLaser3CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.136 | INTEGER | read-only | mandatory |
| oaLaser3CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.137 | INTEGER | read-only | mandatory |
| oaLaser3CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.138 | INTEGER | read-only | mandatory |
| oaLaser3CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.139 | INTEGER | read-only | mandatory |
| oaLaser3CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.140 | INTEGER | read-only | mandatory |
| oaLaser3TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.141 | INTEGER | read-only | mandatory |
| oaLaser3TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.142 | INTEGER | read-only | mandatory |
| oaLaser3TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.143 | INTEGER | read-only | mandatory |
| oaLaser3TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.144 | INTEGER | read-only | mandatory |
| oaLaser3TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.145 | INTEGER | read-only | mandatory |
| oaLaser3TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.146 | INTEGER | read-only | mandatory |
| oaLaser3TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.147 | INTEGER | read-only | mandatory |
| oaLaser3TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.148 | INTEGER | read-only | mandatory |
| oaLaser3TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.149 | INTEGER | read-only | mandatory |
| oaLaser3TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.150 | INTEGER | read-only | mandatory |
| oaLaser3VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.151 | INTEGER | read-only | optional |
| oaLaser3VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.152 | INTEGER | read-only | optional |
| oaLaser3VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.153 | INTEGER | read-only | optional |
| oaLaser3VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.154 | INTEGER | read-only | optional |
| oaLaser3VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.155 | INTEGER | read-only | optional |
| oaLaser4CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.161 | INTEGER | read-only | mandatory |
| oaLaser4CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.162 | INTEGER | read-only | mandatory |
| oaLaser4CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.163 | INTEGER | read-only | mandatory |
| oaLaser4CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.164 | INTEGER | read-only | mandatory |
| oaLaser4CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.165 | INTEGER | read-only | mandatory |
| oaLaser4TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.166 | INTEGER | read-only | mandatory |
| oaLaser4TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.167 | INTEGER | read-only | mandatory |
| oaLaser4TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.168 | INTEGER | read-only | mandatory |
| oaLaser4TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.169 | INTEGER | read-only | mandatory |
| oaLaser4TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.170 | INTEGER | read-only | mandatory |
| oaLaser4TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.171 | INTEGER | read-only | mandatory |
| oaLaser4TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.172 | INTEGER | read-only | mandatory |
| oaLaser4TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.173 | INTEGER | read-only | mandatory |
| oaLaser4TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.174 | INTEGER | read-only | mandatory |
| oaLaser4TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.175 | INTEGER | read-only | mandatory |
| oaLaser4VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.176 | INTEGER | read-only | optional |
| oaLaser4VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.177 | INTEGER | read-only | optional |
| oaLaser4VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.178 | INTEGER | read-only | optional |
| oaLaser4VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.179 | INTEGER | read-only | optional |
| oaLaser4VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.180 | INTEGER | read-only | optional |
| oaLaser5CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.186 | INTEGER | read-only | mandatory |
| oaLaser5CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.187 | INTEGER | read-only | mandatory |
| oaLaser5CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.188 | INTEGER | read-only | mandatory |
| oaLaser5CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.189 | INTEGER | read-only | mandatory |
| oaLaser5CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.190 | INTEGER | read-only | mandatory |
| oaLaser5TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.191 | INTEGER | read-only | mandatory |
| oaLaser5TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.192 | INTEGER | read-only | mandatory |
| oaLaser5TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.193 | INTEGER | read-only | mandatory |
| oaLaser5TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.194 | INTEGER | read-only | mandatory |
| oaLaser5TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.195 | INTEGER | read-only | mandatory |
| oaLaser5TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.196 | INTEGER | read-only | mandatory |
| oaLaser5TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.197 | INTEGER | read-only | mandatory |
| oaLaser5TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.198 | INTEGER | read-only | mandatory |
| oaLaser5TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.199 | INTEGER | read-only | mandatory |
| oaLaser5TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.200 | INTEGER | read-only | mandatory |
| oaLaser5VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.201 | INTEGER | read-only | optional |
| oaLaser5VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.202 | INTEGER | read-only | optional |
| oaLaser5VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.203 | INTEGER | read-only | optional |
| oaLaser5VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.204 | INTEGER | read-only | optional |
| oaLaser5VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.205 | INTEGER | read-only | optional |
| oaLaser6CurrentRelLoLo OBJECT-TYPE Relative laser no.1 current low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.211 | INTEGER | read-only | mandatory |
| oaLaser6CurrentRelLo OBJECT-TYPE Relative laser no.1 current low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.212 | INTEGER | read-only | mandatory |
| oaLaser6CurrentRelValue OBJECT-TYPE The laser no.1 current relative to the current at begin of life in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.213 | INTEGER | read-only | mandatory |
| oaLaser6CurrentRelHi OBJECT-TYPE Relative laser no.1 current high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.214 | INTEGER | read-only | mandatory |
| oaLaser6CurrentRelHiHi OBJECT-TYPE Relative laser no.1 current high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.215 | INTEGER | read-only | mandatory |
| oaLaser6TecRelLoLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.216 | INTEGER | read-only | mandatory |
| oaLaser6TecRelLo OBJECT-TYPE Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.217 | INTEGER | read-only | mandatory |
| oaLaser6TecRelValue OBJECT-TYPE The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.218 | INTEGER | read-only | mandatory |
| oaLaser6TecRelHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.219 | INTEGER | read-only | mandatory |
| oaLaser6TecRelHiHi OBJECT-TYPE Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.220 | INTEGER | read-only | mandatory |
| oaLaser6TemperatureLoLo OBJECT-TYPE Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.221 | INTEGER | read-only | mandatory |
| oaLaser6TemperatureLo OBJECT-TYPE Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.222 | INTEGER | read-only | mandatory |
| oaLaser6TemperatureValue OBJECT-TYPE Temperature of laser no.1 in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.223 | INTEGER | read-only | mandatory |
| oaLaser6TemperatureHi OBJECT-TYPE Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.224 | INTEGER | read-only | mandatory |
| oaLaser6TemperatureHiHi OBJECT-TYPE Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.225 | INTEGER | read-only | mandatory |
| oaLaser6VoltageLoLo OBJECT-TYPE The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.226 | INTEGER | read-only | optional |
| oaLaser6VoltageLo OBJECT-TYPE The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.227 | INTEGER | read-only | optional |
| oaLaser6VoltageValue OBJECT-TYPE The supply voltage of laser no.1 in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.228 | INTEGER | read-only | optional |
| oaLaser6VoltageHi OBJECT-TYPE The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.229 | INTEGER | read-only | optional |
| oaLaser6VoltageHiHi OBJECT-TYPE The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.116.5.1.1.230 | INTEGER | read-only | optional |
| oaDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.116.6 | |||
| oaDisplayTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.6.1 | not-accessible | mandatory | |
| oaDisplayEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.116.6.1.1 | not-accessible | mandatory | |
| oaDisplayNumberOfLasers OBJECT-TYPE The number of lasers used by this optical amplifier | 1.3.6.1.4.1.7501.1.2.116.6.1.1.1 | INTEGER | read-only | mandatory |
| oaDisplayNumberOfInternalVoltages OBJECT-TYPE The number of internal voltages monitored by this optical amplifier | 1.3.6.1.4.1.7501.1.2.116.6.1.1.2 | INTEGER | read-only | optional |
| oaDisplayExtIOSupported OBJECT-TYPE Return 'true(1)' if external I/O feature is supported by the device. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.3 | TruthValue | read-only | mandatory |
| oaDisplaySbsSupported OBJECT-TYPE Return 'true(1)' if SBS feature is supported by the device. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.4 | TruthValue | read-only | mandatory |
| oaDisplayReturnLossSupported OBJECT-TYPE Return 'true(1)' if ReturnLoss feature is supported by the device. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.5 | TruthValue | read-only | mandatory |
| oaDisplaySbsEvaluatedThreshold OBJECT-TYPE The evaluated SBS output power or gain threshold in 0.1 dB(m) units. Not supported by all optical amplifiers | 1.3.6.1.4.1.7501.1.2.116.6.1.1.6 | INTEGER | read-only | mandatory |
| oaDisplaySbsLastEvaluationState OBJECT-TYPE The result of last SBS threshold evaluation process. Returns 'evaluationNotSupported(1)' if SBS threshold evaluation is not supported by this optical amplifier | 1.3.6.1.4.1.7501.1.2.116.6.1.1.7 | SbsEvaluationState | read-only | mandatory |
| oaDisplaySbsLastEvaluationTime OBJECT-TYPE The time of last successfull SBS threshold evaluation process. Not supported by all optical amplifiers | 1.3.6.1.4.1.7501.1.2.116.6.1.1.8 | DisplayString | read-only | mandatory |
| oaDisplayOutputPwrOrGainNominal OBJECT-TYPE The nominal value of output power (or gain) in 0.1 dB(m) units. See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.6.1.1.9 | INTEGER | read-only | mandatory |
| oaDisplayOutputPwrOrGainAdjusted OBJECT-TYPE The adjusted desired value of output power (or gain) in 0.1 dB(m) units. See oaConfigRegulationMode variable too | 1.3.6.1.4.1.7501.1.2.116.6.1.1.10 | INTEGER | read-only | mandatory |
| oaDisplayInputVoltageNominal OBJECT-TYPE The nominal value of input voltage in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.11 | INTEGER | read-only | optional |
| oaDisplayInternalVoltage1Nominal OBJECT-TYPE The nominal value of internal voltage no. 1 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.12 | INTEGER | read-only | optional |
| oaDisplayInternalVoltage2Nominal OBJECT-TYPE The nominal value of internal voltage no. 2 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.13 | INTEGER | read-only | optional |
| oaDisplayInternalVoltage3Nominal OBJECT-TYPE The nominal value of internal voltage no. 3 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.14 | INTEGER | read-only | optional |
| oaDisplayLaser1VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.1 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.20 | INTEGER | read-only | optional |
| oaDisplayLaser2VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.2 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.21 | INTEGER | read-only | optional |
| oaDisplayLaser3VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.3 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.22 | INTEGER | read-only | optional |
| oaDisplayLaser4VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.4 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.23 | INTEGER | read-only | optional |
| oaDisplayLaser5VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.5 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.24 | INTEGER | read-only | optional |
| oaDisplayLaser6VoltageNominal OBJECT-TYPE The nominal supply voltage of laser no.6 in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.25 | INTEGER | read-only | optional |
| oaDisplayLaser1PumpPowerRel OBJECT-TYPE The pump power of laser no.1 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.30 | INTEGER | read-only | mandatory |
| oaDisplayLaser2PumpPowerRel OBJECT-TYPE The pump power of laser no.2 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.31 | INTEGER | read-only | mandatory |
| oaDisplayLaser3PumpPowerRel OBJECT-TYPE The pump power of laser no.3 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.32 | INTEGER | read-only | mandatory |
| oaDisplayLaser4PumpPowerRel OBJECT-TYPE The pump power of laser no.4 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.33 | INTEGER | read-only | mandatory |
| oaDisplayLaser5PumpPowerRel OBJECT-TYPE The pump power of laser no.5 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.34 | INTEGER | read-only | mandatory |
| oaDisplayLaser6PumpPowerRel OBJECT-TYPE The pump power of laser no.6 in steps of 0.1% | 1.3.6.1.4.1.7501.1.2.116.6.1.1.35 | INTEGER | read-only | mandatory |
| oaDisplayLaser1FeaturesSupported OBJECT-TYPE The features supported by laser no.1 A bitfield containing the features supplied by this laser. Note that laserCurrent is always supplied. | 1.3.6.1.4.1.7501.1.2.116.6.1.1.40 | LaserFeatures | read-only | mandatory |
| oaDisplayLaser2FeaturesSupported OBJECT-TYPE The features supported by laser no.2 | 1.3.6.1.4.1.7501.1.2.116.6.1.1.41 | LaserFeatures | read-only | mandatory |
| oaDisplayLaser3FeaturesSupported OBJECT-TYPE The features supported by laser no.3 | 1.3.6.1.4.1.7501.1.2.116.6.1.1.42 | LaserFeatures | read-only | mandatory |
| oaDisplayLaser4FeaturesSupported OBJECT-TYPE The features supported by laser no.4 | 1.3.6.1.4.1.7501.1.2.116.6.1.1.43 | LaserFeatures | read-only | mandatory |
| oaDisplayLaser5FeaturesSupported OBJECT-TYPE The features supported by laser no.5 | 1.3.6.1.4.1.7501.1.2.116.6.1.1.44 | LaserFeatures | read-only | mandatory |
| oaDisplayLaser6FeaturesSupported OBJECT-TYPE The features supported by laser no.6 | 1.3.6.1.4.1.7501.1.2.116.6.1.1.45 | LaserFeatures | read-only | mandatory |
| oaDisplayAmplifierIsRamanType OBJECT-TYPE Returns true(1) if this amplifier is of RAMAN type | 1.3.6.1.4.1.7501.1.2.116.6.1.1.50 | TruthValue | read-only | mandatory |