BKTEL-HFC862-NECE-MIB
- Registered at
- 1.3.6.1.4.1.7501.1.2.100
- Namespace
- bktel
- Source file
BKTEL-HFC862-NECE-MIB- Digest
sha256:7c476aeafd6f4fcae386aac55f8b2d9f23777e9f6fe57252e42bda03ad62fa38
Imports
| From | Symbols |
|---|---|
| BKTEL-HFC862-BASE-MIB | DisplayString, ModuleWidthValue, NESlotValue, PerceivedSeverityValue, TruthValue, modules |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, experimental, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BKTEL-HFC862-BASE-MIB BKTEL-HFC862-NECE-MIB RFC1155-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| GpioLogicLevel type | ||||
| GpioMode type | ||||
| GpioType type | ||||
| HfcInventoryFormatValue type | ||||
| HmsTrapsComplianceValue type | ||||
| NESlotWriteValue type | ||||
| TrapAccumulationTimeValue type | ||||
| TrapVerifyTimeoutValue type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| nece OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100 | |||
| neceCommon OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.1 | |||
| neceCommonNumberOfModules OBJECT-TYPE Number of modules in table. | 1.3.6.1.4.1.7501.1.2.100.1.1 | INTEGER | read-only | mandatory |
| neceCommonTable OBJECT-TYPE The table contains all modules of the nece-type in the NE | 1.3.6.1.4.1.7501.1.2.100.1.2 | not-accessible | mandatory | |
| neceCommonEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.100.1.2.1 | not-accessible | mandatory | |
| neceNESlot OBJECT-TYPE The virtual slotID | 1.3.6.1.4.1.7501.1.2.100.1.2.1.1 | NESlotValue | read-only | mandatory |
| neceCommonType OBJECT-TYPE Module model name | 1.3.6.1.4.1.7501.1.2.100.1.2.1.2 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| neceCommonDescr OBJECT-TYPE Module alias name | 1.3.6.1.4.1.7501.1.2.100.1.2.1.3 | DisplayString | read-write | mandatory |
| neceCommonFirmwareId OBJECT-TYPE Module firmware version | 1.3.6.1.4.1.7501.1.2.100.1.2.1.4 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| neceCommonModuleWidth OBJECT-TYPE The width of the module. | 1.3.6.1.4.1.7501.1.2.100.1.2.1.5 | ModuleWidthValue | read-only | optional |
| neceStates OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.2 | |||
| neceStatesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.2.1 | not-accessible | mandatory | |
| neceStatesEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.100.2.1.1 | not-accessible | mandatory | |
| neceStatesGpInput1 OBJECT-TYPE State of general purpose input no. 1. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.1 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput2 OBJECT-TYPE State of general purpose input no. 2. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.2 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput3 OBJECT-TYPE State of general purpose input no. 3. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.3 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput4 OBJECT-TYPE State of general purpose input no. 4. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.4 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput5 OBJECT-TYPE State of general purpose input no. 5. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.5 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput6 OBJECT-TYPE State of general purpose input no. 6. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.6 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput7 OBJECT-TYPE State of general purpose input no. 7. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.7 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput8 OBJECT-TYPE State of general purpose input no. 8. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.8 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput9 OBJECT-TYPE State of general purpose input no. 9. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.9 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput10 OBJECT-TYPE State of general purpose input no. 10. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.10 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput11 OBJECT-TYPE State of general purpose input no. 11. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.11 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesGpInput12 OBJECT-TYPE State of general purpose input no. 12. | 1.3.6.1.4.1.7501.1.2.100.2.1.1.12 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesPowerSupplyLeft OBJECT-TYPE The left (looking from front side) power supply unit fails. Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5) | 1.3.6.1.4.1.7501.1.2.100.2.1.1.13 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesPowerSupplyRight OBJECT-TYPE The right (looking from front side) power supply unit fails. Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5) | 1.3.6.1.4.1.7501.1.2.100.2.1.1.14 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesFanLeft OBJECT-TYPE The left (looking from front side) fan unit fails. Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5) | 1.3.6.1.4.1.7501.1.2.100.2.1.1.15 | PerceivedSeverityValue | read-only | mandatory |
| neceStatesFanRight OBJECT-TYPE The right (looking from front side) fan unit fails. Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5) | 1.3.6.1.4.1.7501.1.2.100.2.1.1.16 | PerceivedSeverityValue | read-only | mandatory |
| neceConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.3 | |||
| neceConfigurationTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.3.1 | not-accessible | mandatory | |
| neceConfigurationEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.3.1.1 | not-accessible | mandatory | |
| neceConfigGpio1Type OBJECT-TYPE The type of the general purpose port no. 1 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.1 | GpioType | read-only | mandatory |
| neceConfigGpio1Mode OBJECT-TYPE The mode of the general purpose port no. 1 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.2 | GpioMode | read-write | mandatory |
| neceConfigGpio1LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 1 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.3 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio1Description OBJECT-TYPE A description for the general purpose port no. 1 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.4 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio2Type OBJECT-TYPE The type of the general purpose port no. 2 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.5 | GpioType | read-only | mandatory |
| neceConfigGpio2Mode OBJECT-TYPE The mode of the general purpose port no. 2 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.6 | GpioMode | read-write | mandatory |
| neceConfigGpio2LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 2 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.7 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio2Description OBJECT-TYPE A description for the general purpose port no. 2 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.8 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio3Type OBJECT-TYPE The type of the general purpose port no. 3 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.9 | GpioType | read-only | mandatory |
| neceConfigGpio3Mode OBJECT-TYPE The mode of the general purpose port no. 3 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.10 | GpioMode | read-write | mandatory |
| neceConfigGpio3LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 3 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.11 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio3Description OBJECT-TYPE A description for the general purpose port no. 3 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.12 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio4Type OBJECT-TYPE The type of the general purpose port no. 4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.13 | GpioType | read-only | mandatory |
| neceConfigGpio4Mode OBJECT-TYPE The mode of the general purpose port no. 4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.14 | GpioMode | read-write | mandatory |
| neceConfigGpio4LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.15 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio4Description OBJECT-TYPE A description for the general purpose port no. 4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.16 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio5Type OBJECT-TYPE The type of the general purpose port no. 5 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.17 | GpioType | read-only | mandatory |
| neceConfigGpio5Mode OBJECT-TYPE The mode of the general purpose port no. 5 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.18 | GpioMode | read-write | mandatory |
| neceConfigGpio5LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 5 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.19 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio5Description OBJECT-TYPE A description for the general purpose port no. 5 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.20 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio6Type OBJECT-TYPE The type of the general purpose port no. 6 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.21 | GpioType | read-only | mandatory |
| neceConfigGpio6Mode OBJECT-TYPE The mode of the general purpose port no. 6 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.22 | GpioMode | read-write | mandatory |
| neceConfigGpio6LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 6 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.23 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio6Description OBJECT-TYPE A description for the general purpose port no. 6 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.24 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio7Type OBJECT-TYPE The type of the general purpose port no. 7 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.25 | GpioType | read-only | mandatory |
| neceConfigGpio7Mode OBJECT-TYPE The mode of the general purpose port no. 7 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.26 | GpioMode | read-write | mandatory |
| neceConfigGpio7LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 7 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.27 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio7Description OBJECT-TYPE A description for the general purpose port no. 7 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.28 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio8Type OBJECT-TYPE The type of the general purpose port no. 8 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.29 | GpioType | read-only | mandatory |
| neceConfigGpio8Mode OBJECT-TYPE The mode of the general purpose port no. 8 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.30 | GpioMode | read-write | mandatory |
| neceConfigGpio8LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 8 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.31 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio8Description OBJECT-TYPE A description for the general purpose port no. 8 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.32 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio9Type OBJECT-TYPE The type of the general purpose port no. 9 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.33 | GpioType | read-only | mandatory |
| neceConfigGpio9Mode OBJECT-TYPE The mode of the general purpose port no. 9 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.34 | GpioMode | read-write | mandatory |
| neceConfigGpio9LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 9 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.35 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio9Description OBJECT-TYPE A description for the general purpose port no. 9 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.36 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio10Type OBJECT-TYPE The type of the general purpose port no. 10 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.37 | GpioType | read-only | mandatory |
| neceConfigGpio10Mode OBJECT-TYPE The mode of the general purpose port no. 10 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.38 | GpioMode | read-write | mandatory |
| neceConfigGpio10LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 10 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.39 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio10Description OBJECT-TYPE A description for the general purpose port no. 10 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.40 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio11Type OBJECT-TYPE The type of the general purpose port no. 11 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.41 | GpioType | read-only | mandatory |
| neceConfigGpio11Mode OBJECT-TYPE The mode of the general purpose port no. 11 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.42 | GpioMode | read-write | mandatory |
| neceConfigGpio11LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 11 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.43 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio11Description OBJECT-TYPE A description for the general purpose port no. 11 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.44 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigGpio12Type OBJECT-TYPE The type of the general purpose port no. 12 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.45 | GpioType | read-only | mandatory |
| neceConfigGpio12Mode OBJECT-TYPE The mode of the general purpose port no. 12 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.46 | GpioMode | read-write | mandatory |
| neceConfigGpio12LogicLevel OBJECT-TYPE The logic level of the general purpose port no. 12 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.47 | GpioLogicLevel | read-write | mandatory |
| neceConfigGpio12Description OBJECT-TYPE A description for the general purpose port no. 12 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.48 | DisplayString (SIZE(0..31)) | read-write | mandatory |
| neceConfigNESlotWrite OBJECT-TYPE By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.49 | NESlotWriteValue | read-write | optional |
| neceConfigIpAddress OBJECT-TYPE The ip address of the NEC. NOTE: The NECE executes a reset if this parameter gets changed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.50 | IpAddress | read-write | mandatory |
| neceConfigNetmask OBJECT-TYPE The netmask of the NEC. NOTE: The NECE executes a reset if this parameter gets changed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.51 | IpAddress | read-write | mandatory |
| neceConfigDefaultrouter OBJECT-TYPE The default router of the NEC. NOTE: The NECE executes a reset if this parameter gets changed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.52 | IpAddress | read-write | mandatory |
| neceConfigTrapReceiver1HostIp OBJECT-TYPE The ip address of the host no.1 that should receive traps Address 0.0.0.0 disables the trap. Broad- or multicast addresses are not allowed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.53 | IpAddress | read-write | mandatory |
| neceConfigTrapReceiver1Community OBJECT-TYPE The community name used for traps to host no.1 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.54 | DisplayString (SIZE(4..31)) | read-write | mandatory |
| neceConfigTrapReceiver2HostIp OBJECT-TYPE The ip address of the host no.2 that should receive traps Address 0.0.0.0 disables the trap. Broad- or multicast addresses are not allowed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.55 | IpAddress | read-write | mandatory |
| neceConfigTrapReceiver2to4Community OBJECT-TYPE The community name used for traps to hosts no.2 to no.4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.56 | DisplayString (SIZE(4..31)) | read-write | mandatory |
| neceConfigTrapReceiver3HostIp OBJECT-TYPE The ip address of the host no.3 that should receive traps Address 0.0.0.0 disables the trap. Broad- or multicast addresses are not allowed NOTE: The community name 'neceConfigTrapReceiver2to4Community' is used for this trap receiver no. 3 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.57 | IpAddress | read-write | mandatory |
| neceConfigTrapReceiver4HostIp OBJECT-TYPE The ip address of the host no.4 that should receive traps Address 0.0.0.0 disables the trap. Broad- or multicast addresses are not allowed NOTE: The community name 'neceConfigTrapReceiver2to4Community' is used for this trap receiver no. 4 | 1.3.6.1.4.1.7501.1.2.100.3.1.1.58 | IpAddress | read-write | mandatory |
| neceConfigGetCommunity OBJECT-TYPE The community name that is allowed for GET requests NOTES: - By writing 'neceConfigGetCommunity' AND 'neceConfigSetCommunity' to an empty string of size 0, the default community settings are used. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.59 | DisplayString (SIZE(0..15)) | read-write | mandatory |
| neceConfigSetCommunity OBJECT-TYPE The community name that is allowed for SET and GET requests NOTES: - By writing 'neceConfigGetCommunity' AND 'neceConfigSetCommunity' to an empty string of size 0, the default community settings are used. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.60 | DisplayString (SIZE(0..15)) | read-write | mandatory |
| neceConfigTrapReceiverVerify OBJECT-TYPE If TRUE, the NECE verifies if the 'sysDescr' variable is readable on host with ip-address 'neceConfigTrapVerifyReceiverIp' before sending new traps. NOTE: The NECE executes a reset if this parameter gets changed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.61 | TruthValue | read-write | mandatory |
| neceConfigTrapVerifyReceiverIp OBJECT-TYPE The ip address of the host that should receive the 'sysDescr' verify request. Broad- or multicast addresses are not allowed. !!! Only valid if neceConfigTrapReceiverVerify == true(1) !!! | 1.3.6.1.4.1.7501.1.2.100.3.1.1.62 | IpAddress | read-write | mandatory |
| neceConfigTrapVerifyTimeout OBJECT-TYPE Timeout in seconds after which the NECE stops trying to verify 'sysDescr'. All pending traps are sent, although no verify response, after that timeout. !!! Only valid if neceConfigTrapReceiverVerify == true(1) !!! | 1.3.6.1.4.1.7501.1.2.100.3.1.1.63 | TrapVerifyTimeoutValue | read-write | mandatory |
| neceConfigTrapAccumulationTime OBJECT-TYPE Time in seconds that the NECE waits before sending all pending traps. NOTE: There are two condition where the NECE sends its pending traps earlier ignoring this accumulation time (of course verifying first): 1) The NECE's internal trap buffer is 3/4 full 2) The NECE's SNMP agent is polled by a request from manager !!! Only valid if neceConfigTrapReceiverVerify == true(1) !!! | 1.3.6.1.4.1.7501.1.2.100.3.1.1.64 | TrapAccumulationTimeValue | read-write | mandatory |
| neceConfigCableWatchUsed OBJECT-TYPE This parameter is obsolete and no more needed, always returns false(2) | 1.3.6.1.4.1.7501.1.2.100.3.1.1.65 | TruthValue | read-write | mandatory |
| neceConfigHmsTrapsCompliance OBJECT-TYPE Set the compliance mode of the SCTE HMS traps In earlier versions of NECE (<= Sw.Rel. 1.10) the trap compliance to the SCTE HMS MIBs was not fully given. See manual for details. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.66 | HmsTrapsComplianceValue | read-write | mandatory |
| neceConfigHmsNotificationsEnable OBJECT-TYPE With this control the user can disable all traps of type NOTIFY and there entries in the SCTE HMS tree. NOTE: The NECE executes a reset if this parameter gets changed | 1.3.6.1.4.1.7501.1.2.100.3.1.1.67 | TruthValue | read-write | mandatory |
| neceConfigHfcInventoryFormat OBJECT-TYPE Selects the supported format of the hfcInventoryFabricData (T-NOVA-HFC-INVENTORY-MIB) | 1.3.6.1.4.1.7501.1.2.100.3.1.1.68 | HfcInventoryFormatValue | read-only | mandatory |
| neceConfigTimezone OBJECT-TYPE The timezone in units of half hours from GMT (Greenwich Mean Time). For example: Berlin => +2 half hours means GMT+1 hour Tokio => +18 half hours means GMT+9 hours NewYork => -10 half hours means GMT-5 hours NOTE: Not all NECE's support an NTP server. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.69 | INTEGER (-24..24) | read-write | mandatory |
| neceConfigNtpServerIp OBJECT-TYPE The ip address of an NTP time server. Setting the ip to 0.0.0.0 disables the time server lookup. NOTE: Not all NECE's support an NTP server. | 1.3.6.1.4.1.7501.1.2.100.3.1.1.70 | IpAddress | read-write | mandatory |
| neceConfigFactoryCommandLine OBJECT-TYPE A factory internal command interface | 1.3.6.1.4.1.7501.1.2.100.3.1.1.71 | OCTET STRING | read-write | mandatory |
| neceConfigDaylightSavingFrom OBJECT-TYPE Daylight saving start time in a special textformat (see manual for detail) | 1.3.6.1.4.1.7501.1.2.100.3.1.1.72 | DisplayString | read-write | mandatory |
| neceConfigDaylightSavingTo OBJECT-TYPE Daylight saving end time in a special textformat (see manual for detail) | 1.3.6.1.4.1.7501.1.2.100.3.1.1.73 | DisplayString | read-write | mandatory |
| neceControl OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.4 | |||
| neceControlTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.4.1 | not-accessible | mandatory | |
| neceControlEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.100.4.1.1 | not-accessible | mandatory | |
| neceControlReset OBJECT-TYPE Reset the module. | 1.3.6.1.4.1.7501.1.2.100.4.1.1.1 | TruthValue | read-write | mandatory |
| neceMeasuringValues OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.5 | |||
| neceMeasuringValuesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.5.1 | not-accessible | mandatory | |
| neceMeasuringValuesEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.100.5.1.1 | not-accessible | mandatory | |
| neceTemperatureLoLo OBJECT-TYPE Temperature low alarm threshold in steps of 0,1°C. | 1.3.6.1.4.1.7501.1.2.100.5.1.1.1 | INTEGER | read-only | mandatory |
| neceTemperatureLo OBJECT-TYPE Temperature low warning threshold in steps of 0,1°C. | 1.3.6.1.4.1.7501.1.2.100.5.1.1.2 | INTEGER | read-only | mandatory |
| neceTemperatureValue OBJECT-TYPE Temperature in steps of 0,1°C. | 1.3.6.1.4.1.7501.1.2.100.5.1.1.3 | INTEGER | read-only | mandatory |
| neceTemperatureHi OBJECT-TYPE Temperature high warning threshold in steps of 0,1°C. | 1.3.6.1.4.1.7501.1.2.100.5.1.1.4 | INTEGER | read-only | mandatory |
| neceTemperatureHiHi OBJECT-TYPE Temperature high alarm threshold in steps of 0,1°C. | 1.3.6.1.4.1.7501.1.2.100.5.1.1.5 | INTEGER | read-only | mandatory |
| neceDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.100.6 | |||
| neceDisplayTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.6.1 | not-accessible | mandatory | |
| neceDisplayEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.100.6.1.1 | not-accessible | mandatory | |
| neceDisplayTrapsSent OBJECT-TYPE Number of traps that the NECE has sent. | 1.3.6.1.4.1.7501.1.2.100.6.1.1.1 | INTEGER | read-only | mandatory |
| neceDisplayTrapsDiscarded OBJECT-TYPE Number of traps that the NECE has discarded. Discarded traps occur because of trap buffer overflow or timeouts. | 1.3.6.1.4.1.7501.1.2.100.6.1.1.2 | INTEGER | read-only | mandatory |