BKTEL-HFC862-HMSNE-MIB
- Registered at
- 1.3.6.1.4.1.7501.1.1.11.3.6.1.4.1.7501.1.1.21.3.6.1.4.1.7501.1.1.31.3.6.1.4.1.7501.1.1.4
- Namespace
- bktel
- Source file
BKTEL-HFC862-HMSNE-MIB- Digest
sha256:7ef7d239cc1df02205fcc37beeab098a63aef17f2ee7b438a06d4d72f536b1c7
Imports
| From | Symbols |
|---|---|
| BKTEL-HFC862-BASE-MIB | DisplayString, NESlotValue, PerceivedSeverityValue, TruthValue, ne |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BKTEL-HFC862-BASE-MIB BKTEL-HFC862-HMSNE-MIB RFC1155-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| neCommon OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.1.1 | |||
| neType OBJECT-TYPE Type of NE | 1.3.6.1.4.1.7501.1.1.1.1 | DisplayString | read-only | mandatory |
| neDescription OBJECT-TYPE The description of the NE. | 1.3.6.1.4.1.7501.1.1.1.2 | DisplayString | read-only | mandatory |
| neLocationStreet OBJECT-TYPE Location Street of Network Element. Writable size depends on net element controller, default 32 | 1.3.6.1.4.1.7501.1.1.1.3 | DisplayString | read-write | mandatory |
| neLocationCity OBJECT-TYPE Location City of Network Element. Writable size depends on net element controller, default 32 | 1.3.6.1.4.1.7501.1.1.1.4 | DisplayString | read-write | mandatory |
| neObsolete_UsingAPS OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.5 | TruthValue | read-only | obsolete |
| neObsolete_APSMode OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.6 | INTEGER | read-write | obsolete |
| neObsolete_CommonSubrackWidth OBJECT-TYPE This parameter is obsolete. (The width of the Subracks) | 1.3.6.1.4.1.7501.1.1.1.8 | INTEGER | read-only | obsolete |
| neObsolete_CommonSubrackNumber OBJECT-TYPE This parameter is obsolete. (The number of Subracks) | 1.3.6.1.4.1.7501.1.1.1.9 | INTEGER | read-only | obsolete |
| neObsolete_NumberModul OBJECT-TYPE This parameter is obsolete. (Current number of entries in the Modul table) | 1.3.6.1.4.1.7501.1.1.1.10 | INTEGER (1..61) | read-only | obsolete |
| neObsolete_UsingRevertiveMode OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.11 | TruthValue | read-only | obsolete |
| neObsolete_RevertiveMode OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.12 | INTEGER (0..300) | read-write | obsolete |
| neObsolete_InitPhase OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.13 | INTEGER | read-only | obsolete |
| neObsolete_PredecessorRedundantPath OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.14 | IpAddress | read-write | obsolete |
| neObsolete_PredecessorNominalPath OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.1.15 | IpAddress | read-write | obsolete |
| neModuleTable OBJECT-TYPE Table containing information about each Module. | 1.3.6.1.4.1.7501.1.1.1.16 | not-accessible | mandatory | |
| neModuleEntry OBJECT-TYPE List of information about each Module. | 1.3.6.1.4.1.7501.1.1.1.16.1 | not-accessible | mandatory | |
| neModuleNESlot OBJECT-TYPE Slot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subrack based modules as 19 inch modules | 1.3.6.1.4.1.7501.1.1.1.16.1.1 | NESlotValue | read-only | mandatory |
| neModuleSubrack OBJECT-TYPE Subrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number | 1.3.6.1.4.1.7501.1.1.1.16.1.2 | INTEGER | read-only | mandatory |
| neModuleModelName OBJECT-TYPE Module model name | 1.3.6.1.4.1.7501.1.1.1.16.1.3 | DisplayString | read-only | mandatory |
| neModuleMibLink OBJECT-TYPE Defines the link to the OID of the equiped module | 1.3.6.1.4.1.7501.1.1.1.16.1.4 | OBJECT IDENTIFIER | read-only | mandatory |
| neModuleSubrackSlot OBJECT-TYPE Slot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number | 1.3.6.1.4.1.7501.1.1.1.16.1.5 | INTEGER | read-only | mandatory |
| neModuleSlotUnitsUsed OBJECT-TYPE For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within subrack which the module occupies. | 1.3.6.1.4.1.7501.1.1.1.16.1.6 | INTEGER | read-only | mandatory |
| neModuleSlotRackDetection OBJECT-TYPE Reports the state of modules slot and rack hardware detection. | 1.3.6.1.4.1.7501.1.1.1.16.1.7 | INTEGER {notSupported(1), supported(2), detectionError(3)} | read-only | mandatory |
| neModuleHousingType OBJECT-TYPE Module housing type | 1.3.6.1.4.1.7501.1.1.1.16.1.8 | INTEGER {housingUnknownOrDefault(1), housingBk(2), housing2G6(3), housing19inch(4)} | read-only | mandatory |
| neModuleFirmwareVersion OBJECT-TYPE Module firmware version | 1.3.6.1.4.1.7501.1.1.1.16.1.9 | DisplayString | read-only | mandatory |
| neModuleHardwareVersion OBJECT-TYPE Module hardware version | 1.3.6.1.4.1.7501.1.1.1.16.1.10 | DisplayString | read-only | mandatory |
| neModuleDateOfProduction OBJECT-TYPE Module date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of production is defined | 1.3.6.1.4.1.7501.1.1.1.16.1.11 | DisplayString | read-only | mandatory |
| neModuleSerialNumber OBJECT-TYPE Module serial number | 1.3.6.1.4.1.7501.1.1.1.16.1.12 | DisplayString | read-only | mandatory |
| neModuleArticleNumber OBJECT-TYPE Module article number | 1.3.6.1.4.1.7501.1.1.1.16.1.13 | DisplayString | read-only | mandatory |
| neModuleCustomerCode OBJECT-TYPE Customer specific article code | 1.3.6.1.4.1.7501.1.1.1.16.1.14 | DisplayString | read-only | mandatory |
| neModuleAliasName OBJECT-TYPE Module alias name | 1.3.6.1.4.1.7501.1.1.1.16.1.15 | DisplayString | read-write | mandatory |
| neModuleUserdata OBJECT-TYPE Module user data | 1.3.6.1.4.1.7501.1.1.1.16.1.16 | DisplayString | read-write | mandatory |
| neModuleReset OBJECT-TYPE Resets the module if this parameter is written to true(1). | 1.3.6.1.4.1.7501.1.1.1.16.1.17 | TruthValue | read-write | mandatory |
| neModuleLedBlink OBJECT-TYPE Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variable always returns false(2) on read requests | 1.3.6.1.4.1.7501.1.1.1.16.1.18 | TruthValue | read-write | mandatory |
| neStates OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.1.2 | |||
| neStatesObsolete_TrapDisable OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.1 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_TerminalConnected OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.2 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_Isolated OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.4 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_ResetModullist OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.5 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_Redundant OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.6 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_ActivateRedundantPath OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.7 | PerceivedSeverityValue | read-only | obsolete |
| neStatesObsolete_AutoOff OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.2.8 | PerceivedSeverityValue | read-only | obsolete |
| neConfig OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.1.3 | |||
| neConfigObsolete_NEtype OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.3.1 | INTEGER | read-write | obsolete |
| neConfigObsolete_IPaddress OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.3.2 | IpAddress | read-write | obsolete |
| neConfigObsolete_Alarmdelay OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.3.3 | INTEGER (3..60) | read-write | obsolete |
| neConfigDeprecated_MinTrapInterval OBJECT-TYPE This parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface) | 1.3.6.1.4.1.7501.1.1.3.4 | INTEGER (0..10) | read-write | optional |
| neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE This parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface) | 1.3.6.1.4.1.7501.1.1.3.5 | INTEGER (30..300) | read-write | optional |
| neControl OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.1.4 | |||
| neControlTrapDisable OBJECT-TYPE All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2) | 1.3.6.1.4.1.7501.1.1.4.1 | TruthValue | read-write | mandatory |
| neControlResetModullist OBJECT-TYPE This command removes all disconnected (not responding) modules from the module list. | 1.3.6.1.4.1.7501.1.1.4.2 | TruthValue | read-write | mandatory |
| neControlObsolete_SetDefaultAPS OBJECT-TYPE This parameter is obsolete. | 1.3.6.1.4.1.7501.1.1.4.3 | TruthValue | read-write | obsolete |
Notifications
| Name | OID | Status |
|---|---|---|
| neSynchronizeEvent NOTIFICATION-TYPE The SNMP trap that is generated when data on LMT must get actualized. | 1.3.6.1.4.1.7501.1.1.0.1 |