MIBs Depot

BKTEL-HFC862-HMSNE-MIB

Registered at
1.3.6.1.4.1.7501.1.1.1
1.3.6.1.4.1.7501.1.1.2
1.3.6.1.4.1.7501.1.1.3
1.3.6.1.4.1.7501.1.1.4
Namespace
bktel
Source file
BKTEL-HFC862-HMSNE-MIB
Digest
sha256:7ef7d239cc1df02205fcc37beeab098a63aef17f2ee7b438a06d4d72f536b1c7

Imports

FromSymbols
BKTEL-HFC862-BASE-MIBDisplayString, NESlotValue, PerceivedSeverityValue, TruthValue, ne
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BKTEL-HFC862-BASE-MIB
BKTEL-HFC862-HMSNE-MIB
RFC1155-SMI
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
neCommon
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.1.1
neType
OBJECT-TYPE
Type of NE
1.3.6.1.4.1.7501.1.1.1.1DisplayStringread-onlymandatory
neDescription
OBJECT-TYPE
The description of the NE.
1.3.6.1.4.1.7501.1.1.1.2DisplayStringread-onlymandatory
neLocationStreet
OBJECT-TYPE
Location Street of Network Element. Writable size depends on net element controller, default 32
1.3.6.1.4.1.7501.1.1.1.3DisplayStringread-writemandatory
neLocationCity
OBJECT-TYPE
Location City of Network Element. Writable size depends on net element controller, default 32
1.3.6.1.4.1.7501.1.1.1.4DisplayStringread-writemandatory
neObsolete_UsingAPS
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.5TruthValueread-onlyobsolete
neObsolete_APSMode
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.6INTEGERread-writeobsolete
neObsolete_CommonSubrackWidth
OBJECT-TYPE
This parameter is obsolete. (The width of the Subracks)
1.3.6.1.4.1.7501.1.1.1.8INTEGERread-onlyobsolete
neObsolete_CommonSubrackNumber
OBJECT-TYPE
This parameter is obsolete. (The number of Subracks)
1.3.6.1.4.1.7501.1.1.1.9INTEGERread-onlyobsolete
neObsolete_NumberModul
OBJECT-TYPE
This parameter is obsolete. (Current number of entries in the Modul table)
1.3.6.1.4.1.7501.1.1.1.10INTEGER (1..61)read-onlyobsolete
neObsolete_UsingRevertiveMode
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.11TruthValueread-onlyobsolete
neObsolete_RevertiveMode
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.12INTEGER (0..300)read-writeobsolete
neObsolete_InitPhase
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.13INTEGERread-onlyobsolete
neObsolete_PredecessorRedundantPath
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.14IpAddressread-writeobsolete
neObsolete_PredecessorNominalPath
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.15IpAddressread-writeobsolete
neModuleTable
OBJECT-TYPE
Table containing information about each Module.
1.3.6.1.4.1.7501.1.1.1.16not-accessiblemandatory
neModuleEntry
OBJECT-TYPE
List of information about each Module.
1.3.6.1.4.1.7501.1.1.1.16.1not-accessiblemandatory
neModuleNESlot
OBJECT-TYPE
Slot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subrack based modules as 19 inch modules
1.3.6.1.4.1.7501.1.1.1.16.1.1NESlotValueread-onlymandatory
neModuleSubrack
OBJECT-TYPE
Subrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number
1.3.6.1.4.1.7501.1.1.1.16.1.2INTEGERread-onlymandatory
neModuleModelName
OBJECT-TYPE
Module model name
1.3.6.1.4.1.7501.1.1.1.16.1.3DisplayStringread-onlymandatory
neModuleSubrackSlot
OBJECT-TYPE
Slot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number
1.3.6.1.4.1.7501.1.1.1.16.1.5INTEGERread-onlymandatory
neModuleSlotUnitsUsed
OBJECT-TYPE
For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within subrack which the module occupies.
1.3.6.1.4.1.7501.1.1.1.16.1.6INTEGERread-onlymandatory
neModuleSlotRackDetection
OBJECT-TYPE
Reports the state of modules slot and rack hardware detection.
1.3.6.1.4.1.7501.1.1.1.16.1.7INTEGER {notSupported(1), supported(2), detectionError(3)}read-onlymandatory
neModuleHousingType
OBJECT-TYPE
Module housing type
1.3.6.1.4.1.7501.1.1.1.16.1.8INTEGER {housingUnknownOrDefault(1), housingBk(2), housing2G6(3), housing19inch(4)}read-onlymandatory
neModuleFirmwareVersion
OBJECT-TYPE
Module firmware version
1.3.6.1.4.1.7501.1.1.1.16.1.9DisplayStringread-onlymandatory
neModuleHardwareVersion
OBJECT-TYPE
Module hardware version
1.3.6.1.4.1.7501.1.1.1.16.1.10DisplayStringread-onlymandatory
neModuleDateOfProduction
OBJECT-TYPE
Module date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of production is defined
1.3.6.1.4.1.7501.1.1.1.16.1.11DisplayStringread-onlymandatory
neModuleSerialNumber
OBJECT-TYPE
Module serial number
1.3.6.1.4.1.7501.1.1.1.16.1.12DisplayStringread-onlymandatory
neModuleArticleNumber
OBJECT-TYPE
Module article number
1.3.6.1.4.1.7501.1.1.1.16.1.13DisplayStringread-onlymandatory
neModuleCustomerCode
OBJECT-TYPE
Customer specific article code
1.3.6.1.4.1.7501.1.1.1.16.1.14DisplayStringread-onlymandatory
neModuleAliasName
OBJECT-TYPE
Module alias name
1.3.6.1.4.1.7501.1.1.1.16.1.15DisplayStringread-writemandatory
neModuleUserdata
OBJECT-TYPE
Module user data
1.3.6.1.4.1.7501.1.1.1.16.1.16DisplayStringread-writemandatory
neModuleReset
OBJECT-TYPE
Resets the module if this parameter is written to true(1).
1.3.6.1.4.1.7501.1.1.1.16.1.17TruthValueread-writemandatory
neStates
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.1.2
neStatesObsolete_TrapDisable
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.1PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_TerminalConnected
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.2PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_Isolated
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.4PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_ResetModullist
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.5PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_Redundant
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.6PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_ActivateRedundantPath
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.7PerceivedSeverityValueread-onlyobsolete
neStatesObsolete_AutoOff
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.8PerceivedSeverityValueread-onlyobsolete
neConfig
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.1.3
neConfigObsolete_NEtype
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.1INTEGERread-writeobsolete
neConfigObsolete_IPaddress
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.2IpAddressread-writeobsolete
neConfigObsolete_Alarmdelay
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.3INTEGER (3..60)read-writeobsolete
neConfigDeprecated_MinTrapInterval
OBJECT-TYPE
This parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface)
1.3.6.1.4.1.7501.1.1.3.4INTEGER (0..10)read-writeoptional
neConfigDeprecated_MaxTrapLifetime
OBJECT-TYPE
This parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface)
1.3.6.1.4.1.7501.1.1.3.5INTEGER (30..300)read-writeoptional
neControl
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.1.4
neControlTrapDisable
OBJECT-TYPE
All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)
1.3.6.1.4.1.7501.1.1.4.1TruthValueread-writemandatory
neControlResetModullist
OBJECT-TYPE
This command removes all disconnected (not responding) modules from the module list.
1.3.6.1.4.1.7501.1.1.4.2TruthValueread-writemandatory
neControlObsolete_SetDefaultAPS
OBJECT-TYPE
This parameter is obsolete.
1.3.6.1.4.1.7501.1.1.4.3TruthValueread-writeobsolete

Notifications

NameOIDStatus
neSynchronizeEvent
NOTIFICATION-TYPE
The SNMP trap that is generated when data on LMT must get actualized.
1.3.6.1.4.1.7501.1.1.0.1