BKTEL-HFC862-BES-V01-MIB
- Registered at
- 1.3.6.1.4.1.7501.1.2.114
- Namespace
- bktel
- Source file
BKTEL-HFC862-BES-V01-MIB- Digest
sha256:b38123516ec49b5974b1bde1d74cd395a336fcd115077355c9967249bc39e2d0
Imports
| From | Symbols |
|---|---|
| BKTEL-HFC862-BASE-MIB | DisplayString, ModuleWidthValue, NESlotValue, PerceivedSeverityValue, TruthValue, modules |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, experimental, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BKTEL-HFC862-BASE-MIB BKTEL-HFC862-BES-V01-MIB RFC1155-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| NESlotWriteValue type | ||||
| PortDuplexMode type | ||||
| PortFlowControl type | ||||
| PortLinkState type | ||||
| PortSpeed type | ||||
| PortStatus type | ||||
| PortType type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| bes OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114 | |||
| besCommon OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.1 | |||
| besCommonNumberOfModules OBJECT-TYPE Number of modules in table. | 1.3.6.1.4.1.7501.1.2.114.1.1 | INTEGER (0..50) | read-only | mandatory |
| besCommonTable OBJECT-TYPE The table contains all modules of the BES-type in the NE | 1.3.6.1.4.1.7501.1.2.114.1.2 | not-accessible | mandatory | |
| besCommonEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.114.1.2.1 | not-accessible | mandatory | |
| besNESlot OBJECT-TYPE The slot number of the chassis for which this entry contains management information. | 1.3.6.1.4.1.7501.1.2.114.1.2.1.1 | NESlotValue | read-only | mandatory |
| besCommonType OBJECT-TYPE The type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown. | 1.3.6.1.4.1.7501.1.2.114.1.2.1.2 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| besCommonDescr OBJECT-TYPE A textual description of the module. If not available, this Value should be set to a zero length string. | 1.3.6.1.4.1.7501.1.2.114.1.2.1.3 | DisplayString | read-write | mandatory |
| besCommonFirmwareId OBJECT-TYPE The firmware Id of the module. | 1.3.6.1.4.1.7501.1.2.114.1.2.1.4 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| besCommonModuleWidth OBJECT-TYPE The width of the module in multiples of slots (1, 2, ...) | 1.3.6.1.4.1.7501.1.2.114.1.2.1.5 | ModuleWidthValue | read-only | optional |
| besStates OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.2 | |||
| besStatesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.2.1 | not-accessible | mandatory | |
| besStatesEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.114.2.1.1 | not-accessible | mandatory | |
| besStatesBootloader OBJECT-TYPE The device is running in bootloader mode without a legal application software. | 1.3.6.1.4.1.7501.1.2.114.2.1.1.1 | PerceivedSeverityValue | read-only | mandatory |
| besStatesCommLoss OBJECT-TYPE The NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device | 1.3.6.1.4.1.7501.1.2.114.2.1.1.2 | PerceivedSeverityValue | read-only | mandatory |
| besStatesTemperatureLow OBJECT-TYPE Device temperature low | 1.3.6.1.4.1.7501.1.2.114.2.1.1.3 | PerceivedSeverityValue | read-only | mandatory |
| besStatesTemperatureHigh OBJECT-TYPE Device temperature high | 1.3.6.1.4.1.7501.1.2.114.2.1.1.4 | PerceivedSeverityValue | read-only | mandatory |
| besStatesInputVoltageLow OBJECT-TYPE Input supply voltage low | 1.3.6.1.4.1.7501.1.2.114.2.1.1.5 | PerceivedSeverityValue | read-only | mandatory |
| besStatesInputVoltageHigh OBJECT-TYPE Input supply voltage high | 1.3.6.1.4.1.7501.1.2.114.2.1.1.6 | PerceivedSeverityValue | read-only | mandatory |
| besConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.3 | |||
| besConfigurationTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.3.1 | not-accessible | mandatory | |
| besConfigurationEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.3.1.1 | not-accessible | mandatory | |
| besConfigNESlotWrite OBJECT-TYPE By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable. | 1.3.6.1.4.1.7501.1.2.114.3.1.1.1 | NESlotWriteValue | read-write | optional |
| besConfigConfigurationIndex OBJECT-TYPE Index of the active configuration (1..besDisplayNumberOfConfigs) | 1.3.6.1.4.1.7501.1.2.114.3.1.1.2 | INTEGER | read-write | mandatory |
| besConfigConfiguration OBJECT-TYPE Description of the active configuration | 1.3.6.1.4.1.7501.1.2.114.3.1.1.3 | DisplayString | read-only | mandatory |
| besControl OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.4 | |||
| besControlTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.4.1 | not-accessible | mandatory | |
| besControlEntry OBJECT-TYPE Alarms for a module. | 1.3.6.1.4.1.7501.1.2.114.4.1.1 | not-accessible | mandatory | |
| besControlReset OBJECT-TYPE Reset the module. | 1.3.6.1.4.1.7501.1.2.114.4.1.1.1 | TruthValue | read-write | mandatory |
| besControlModuleLedBlink OBJECT-TYPE Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stbes blinking at once. This variable always returns false(2) on read requests | 1.3.6.1.4.1.7501.1.2.114.4.1.1.2 | TruthValue | read-write | mandatory |
| besMeasuringValues OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.5 | |||
| besMeasuringValuesTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.5.1 | not-accessible | mandatory | |
| besMeasuringValuesEntry OBJECT-TYPE Common-Values for a module. | 1.3.6.1.4.1.7501.1.2.114.5.1.1 | not-accessible | mandatory | |
| besTemperatureLoLo OBJECT-TYPE Device temperature low alarm threshold in 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.1 | INTEGER | read-only | mandatory |
| besTemperatureLo OBJECT-TYPE Device temperature low warning threshold in 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.2 | INTEGER | read-only | mandatory |
| besTemperatureValue OBJECT-TYPE Device temperature in 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.3 | INTEGER | read-only | mandatory |
| besTemperatureHi OBJECT-TYPE Device temperature high warning threshold in 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.4 | INTEGER | read-only | mandatory |
| besTemperatureHiHi OBJECT-TYPE Device temperature high alarm threshold in 0.1 celsius degrees. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.5 | INTEGER | read-only | mandatory |
| besInputVoltageLoLo OBJECT-TYPE The input supply voltage low alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.6 | INTEGER | read-only | mandatory |
| besInputVoltageLo OBJECT-TYPE The input supply voltage low warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.7 | INTEGER | read-only | mandatory |
| besInputVoltageValue OBJECT-TYPE The input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'besDisplayInputVoltageNominal' | 1.3.6.1.4.1.7501.1.2.114.5.1.1.8 | INTEGER | read-only | mandatory |
| besInputVoltageHi OBJECT-TYPE The input supply voltage high warning threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.9 | INTEGER | read-only | mandatory |
| besInputVoltageHiHi OBJECT-TYPE The input supply voltage high alarm threshold in steps of 0.1 Volts. | 1.3.6.1.4.1.7501.1.2.114.5.1.1.10 | INTEGER | read-only | mandatory |
| besDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.6 | |||
| besDisplayTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.6.1 | not-accessible | mandatory | |
| besDisplayEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.6.1.1 | not-accessible | mandatory | |
| besDisplayNumberOfPorts OBJECT-TYPE The number of ports | 1.3.6.1.4.1.7501.1.2.114.6.1.1.1 | INTEGER | read-only | mandatory |
| besDisplayInputVoltageNominal OBJECT-TYPE The nominal value of input voltage in 0.1 V units. | 1.3.6.1.4.1.7501.1.2.114.6.1.1.2 | INTEGER | read-only | mandatory |
| besDisplayNumberOfConfigs OBJECT-TYPE The number of different configurations supplied | 1.3.6.1.4.1.7501.1.2.114.6.1.1.3 | INTEGER | read-only | mandatory |
| besDisplayConfiguration1 OBJECT-TYPE Description of configuration no. #1 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.4 | DisplayString | read-only | mandatory |
| besDisplayConfiguration2 OBJECT-TYPE Description of configuration no. #2 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.5 | DisplayString | read-only | mandatory |
| besDisplayConfiguration3 OBJECT-TYPE Description of configuration no. #3 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.6 | DisplayString | read-only | mandatory |
| besDisplayConfiguration4 OBJECT-TYPE Description of configuration no. #4 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.7 | DisplayString | read-only | mandatory |
| besDisplayConfiguration5 OBJECT-TYPE Description of configuration no. #5 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.8 | DisplayString | read-only | mandatory |
| besDisplayConfiguration6 OBJECT-TYPE Description of configuration no. #6 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.9 | DisplayString | read-only | mandatory |
| besDisplayConfiguration7 OBJECT-TYPE Description of configuration no. #7 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.10 | DisplayString | read-only | mandatory |
| besDisplayConfiguration8 OBJECT-TYPE Description of configuration no. #8 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.11 | DisplayString | read-only | mandatory |
| besDisplayConfiguration9 OBJECT-TYPE Description of configuration no. #9 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.12 | DisplayString | read-only | mandatory |
| besDisplayConfiguration10 OBJECT-TYPE Description of configuration no. #10 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.13 | DisplayString | read-only | mandatory |
| besDisplayConfiguration11 OBJECT-TYPE Description of configuration no. #11 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.14 | DisplayString | read-only | mandatory |
| besDisplayConfiguration12 OBJECT-TYPE Description of configuration no. #12 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.15 | DisplayString | read-only | mandatory |
| besDisplayConfiguration13 OBJECT-TYPE Description of configuration no. #13 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.16 | DisplayString | read-only | mandatory |
| besDisplayConfiguration14 OBJECT-TYPE Description of configuration no. #14 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.17 | DisplayString | read-only | mandatory |
| besDisplayConfiguration15 OBJECT-TYPE Description of configuration no. #15 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.18 | DisplayString | read-only | mandatory |
| besDisplayConfiguration16 OBJECT-TYPE Description of configuration no. #16 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.19 | DisplayString | read-only | mandatory |
| besDisplayPorts OBJECT-IDENTITY | 1.3.6.1.4.1.7501.1.2.114.56 | |||
| besDisplayPortsTable OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.56.1 | not-accessible | mandatory | |
| besDisplayPortsEntry OBJECT-TYPE | 1.3.6.1.4.1.7501.1.2.114.56.1.1 | not-accessible | mandatory | |
| besDisplayPortsPortIndex OBJECT-TYPE Port index (1..besDisplayNumberOfPorts) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.1 | INTEGER | read-only | mandatory |
| besDisplayPortsPortName OBJECT-TYPE Port name | 1.3.6.1.4.1.7501.1.2.114.56.1.1.2 | DisplayString | read-only | mandatory |
| besDisplayPortsType OBJECT-TYPE Port type | 1.3.6.1.4.1.7501.1.2.114.56.1.1.3 | PortType | read-only | mandatory |
| besDisplayPortsLinkState OBJECT-TYPE Port link status | 1.3.6.1.4.1.7501.1.2.114.56.1.1.4 | PortLinkState | read-only | mandatory |
| besDisplayPortsStatus OBJECT-TYPE Port status | 1.3.6.1.4.1.7501.1.2.114.56.1.1.5 | PortStatus | read-only | mandatory |
| besDisplayPortsDuplexMode OBJECT-TYPE Port duplex mode | 1.3.6.1.4.1.7501.1.2.114.56.1.1.6 | PortDuplexMode | read-only | mandatory |
| besDisplayPortsSpeed OBJECT-TYPE Port speed | 1.3.6.1.4.1.7501.1.2.114.56.1.1.7 | PortSpeed | read-only | mandatory |
| besDisplayPortsFlowControl OBJECT-TYPE Port speed | 1.3.6.1.4.1.7501.1.2.114.56.1.1.8 | PortFlowControl | read-only | mandatory |
| besDisplayPortsFiberTxDistance OBJECT-TYPE Port transmission distance in units of km (Fiber ports only) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.9 | INTEGER | read-only | mandatory |
| besDisplayPortsFiberTxWavelen OBJECT-TYPE Port transmission wavelength in units of nm (Fiber ports only) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.10 | INTEGER | read-only | mandatory |
| besDisplayPortsFiberRxWavelenMin OBJECT-TYPE Port minimum receive wavelength in units of nm (Fiber ports only) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.11 | INTEGER | read-only | mandatory |
| besDisplayPortsFiberRxWavelenMax OBJECT-TYPE Port maximum receive wavelength in units of nm (Fiber ports only) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.12 | INTEGER | read-only | mandatory |
| besDisplayPortsFiberSfpData OBJECT-TYPE Port SFP data text (Fiber ports only) | 1.3.6.1.4.1.7501.1.2.114.56.1.1.13 | DisplayString | read-only | mandatory |