MIBs Depot

BKTEL-HFC862-BES-V01-MIB

Registered at
1.3.6.1.4.1.7501.1.2.114
Namespace
bktel
Source file
BKTEL-HFC862-BES-V01-MIB
Digest
sha256:b38123516ec49b5974b1bde1d74cd395a336fcd115077355c9967249bc39e2d0

Imports

FromSymbols
BKTEL-HFC862-BASE-MIBDisplayString, ModuleWidthValue, NESlotValue, PerceivedSeverityValue, TruthValue, modules
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, experimental, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

BKTEL-HFC862-BASE-MIB
BKTEL-HFC862-BES-V01-MIB
RFC1155-SMI
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
NESlotWriteValue
type
PortDuplexMode
type
PortFlowControl
type
PortLinkState
type
PortSpeed
type
PortStatus
type
PortType
type

Objects

NameOIDSyntaxAccessStatus
bes
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114
besCommon
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.1
besCommonNumberOfModules
OBJECT-TYPE
Number of modules in table.
1.3.6.1.4.1.7501.1.2.114.1.1INTEGER (0..50)read-onlymandatory
besCommonTable
OBJECT-TYPE
The table contains all modules of the BES-type in the NE
1.3.6.1.4.1.7501.1.2.114.1.2not-accessiblemandatory
besCommonEntry
OBJECT-TYPE
Common-Values for a module.
1.3.6.1.4.1.7501.1.2.114.1.2.1not-accessiblemandatory
besNESlot
OBJECT-TYPE
The slot number of the chassis for which this entry contains management information.
1.3.6.1.4.1.7501.1.2.114.1.2.1.1NESlotValueread-onlymandatory
besCommonType
OBJECT-TYPE
The type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown.
1.3.6.1.4.1.7501.1.2.114.1.2.1.2DisplayString (SIZE(0..32))read-onlymandatory
besCommonDescr
OBJECT-TYPE
A textual description of the module. If not available, this Value should be set to a zero length string.
1.3.6.1.4.1.7501.1.2.114.1.2.1.3DisplayStringread-writemandatory
besCommonFirmwareId
OBJECT-TYPE
The firmware Id of the module.
1.3.6.1.4.1.7501.1.2.114.1.2.1.4DisplayString (SIZE(0..32))read-onlymandatory
besCommonModuleWidth
OBJECT-TYPE
The width of the module in multiples of slots (1, 2, ...)
1.3.6.1.4.1.7501.1.2.114.1.2.1.5ModuleWidthValueread-onlyoptional
besStates
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.2
besStatesTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.2.1not-accessiblemandatory
besStatesEntry
OBJECT-TYPE
Alarms for a module.
1.3.6.1.4.1.7501.1.2.114.2.1.1not-accessiblemandatory
besStatesBootloader
OBJECT-TYPE
The device is running in bootloader mode without a legal application software.
1.3.6.1.4.1.7501.1.2.114.2.1.1.1PerceivedSeverityValueread-onlymandatory
besStatesCommLoss
OBJECT-TYPE
The NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device
1.3.6.1.4.1.7501.1.2.114.2.1.1.2PerceivedSeverityValueread-onlymandatory
besStatesTemperatureLow
OBJECT-TYPE
Device temperature low
1.3.6.1.4.1.7501.1.2.114.2.1.1.3PerceivedSeverityValueread-onlymandatory
besStatesTemperatureHigh
OBJECT-TYPE
Device temperature high
1.3.6.1.4.1.7501.1.2.114.2.1.1.4PerceivedSeverityValueread-onlymandatory
besStatesInputVoltageLow
OBJECT-TYPE
Input supply voltage low
1.3.6.1.4.1.7501.1.2.114.2.1.1.5PerceivedSeverityValueread-onlymandatory
besStatesInputVoltageHigh
OBJECT-TYPE
Input supply voltage high
1.3.6.1.4.1.7501.1.2.114.2.1.1.6PerceivedSeverityValueread-onlymandatory
besConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.3
besConfigurationTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.3.1not-accessiblemandatory
besConfigurationEntry
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.3.1.1not-accessiblemandatory
besConfigNESlotWrite
OBJECT-TYPE
By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable.
1.3.6.1.4.1.7501.1.2.114.3.1.1.1NESlotWriteValueread-writeoptional
besConfigConfigurationIndex
OBJECT-TYPE
Index of the active configuration (1..besDisplayNumberOfConfigs)
1.3.6.1.4.1.7501.1.2.114.3.1.1.2INTEGERread-writemandatory
besConfigConfiguration
OBJECT-TYPE
Description of the active configuration
1.3.6.1.4.1.7501.1.2.114.3.1.1.3DisplayStringread-onlymandatory
besControl
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.4
besControlTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.4.1not-accessiblemandatory
besControlEntry
OBJECT-TYPE
Alarms for a module.
1.3.6.1.4.1.7501.1.2.114.4.1.1not-accessiblemandatory
besControlReset
OBJECT-TYPE
Reset the module.
1.3.6.1.4.1.7501.1.2.114.4.1.1.1TruthValueread-writemandatory
besMeasuringValues
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.5
besMeasuringValuesTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.5.1not-accessiblemandatory
besMeasuringValuesEntry
OBJECT-TYPE
Common-Values for a module.
1.3.6.1.4.1.7501.1.2.114.5.1.1not-accessiblemandatory
besTemperatureLoLo
OBJECT-TYPE
Device temperature low alarm threshold in 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.114.5.1.1.1INTEGERread-onlymandatory
besTemperatureLo
OBJECT-TYPE
Device temperature low warning threshold in 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.114.5.1.1.2INTEGERread-onlymandatory
besTemperatureValue
OBJECT-TYPE
Device temperature in 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.114.5.1.1.3INTEGERread-onlymandatory
besTemperatureHi
OBJECT-TYPE
Device temperature high warning threshold in 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.114.5.1.1.4INTEGERread-onlymandatory
besTemperatureHiHi
OBJECT-TYPE
Device temperature high alarm threshold in 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.114.5.1.1.5INTEGERread-onlymandatory
besInputVoltageLoLo
OBJECT-TYPE
The input supply voltage low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.114.5.1.1.6INTEGERread-onlymandatory
besInputVoltageLo
OBJECT-TYPE
The input supply voltage low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.114.5.1.1.7INTEGERread-onlymandatory
besInputVoltageValue
OBJECT-TYPE
The input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'besDisplayInputVoltageNominal'
1.3.6.1.4.1.7501.1.2.114.5.1.1.8INTEGERread-onlymandatory
besInputVoltageHi
OBJECT-TYPE
The input supply voltage high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.114.5.1.1.9INTEGERread-onlymandatory
besInputVoltageHiHi
OBJECT-TYPE
The input supply voltage high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.114.5.1.1.10INTEGERread-onlymandatory
besDisplay
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.6
besDisplayTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.6.1not-accessiblemandatory
besDisplayEntry
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.6.1.1not-accessiblemandatory
besDisplayNumberOfPorts
OBJECT-TYPE
The number of ports
1.3.6.1.4.1.7501.1.2.114.6.1.1.1INTEGERread-onlymandatory
besDisplayInputVoltageNominal
OBJECT-TYPE
The nominal value of input voltage in 0.1 V units.
1.3.6.1.4.1.7501.1.2.114.6.1.1.2INTEGERread-onlymandatory
besDisplayNumberOfConfigs
OBJECT-TYPE
The number of different configurations supplied
1.3.6.1.4.1.7501.1.2.114.6.1.1.3INTEGERread-onlymandatory
besDisplayConfiguration1
OBJECT-TYPE
Description of configuration no. #1
1.3.6.1.4.1.7501.1.2.114.6.1.1.4DisplayStringread-onlymandatory
besDisplayConfiguration2
OBJECT-TYPE
Description of configuration no. #2
1.3.6.1.4.1.7501.1.2.114.6.1.1.5DisplayStringread-onlymandatory
besDisplayConfiguration3
OBJECT-TYPE
Description of configuration no. #3
1.3.6.1.4.1.7501.1.2.114.6.1.1.6DisplayStringread-onlymandatory
besDisplayConfiguration4
OBJECT-TYPE
Description of configuration no. #4
1.3.6.1.4.1.7501.1.2.114.6.1.1.7DisplayStringread-onlymandatory
besDisplayConfiguration5
OBJECT-TYPE
Description of configuration no. #5
1.3.6.1.4.1.7501.1.2.114.6.1.1.8DisplayStringread-onlymandatory
besDisplayConfiguration6
OBJECT-TYPE
Description of configuration no. #6
1.3.6.1.4.1.7501.1.2.114.6.1.1.9DisplayStringread-onlymandatory
besDisplayConfiguration7
OBJECT-TYPE
Description of configuration no. #7
1.3.6.1.4.1.7501.1.2.114.6.1.1.10DisplayStringread-onlymandatory
besDisplayConfiguration8
OBJECT-TYPE
Description of configuration no. #8
1.3.6.1.4.1.7501.1.2.114.6.1.1.11DisplayStringread-onlymandatory
besDisplayConfiguration9
OBJECT-TYPE
Description of configuration no. #9
1.3.6.1.4.1.7501.1.2.114.6.1.1.12DisplayStringread-onlymandatory
besDisplayConfiguration10
OBJECT-TYPE
Description of configuration no. #10
1.3.6.1.4.1.7501.1.2.114.6.1.1.13DisplayStringread-onlymandatory
besDisplayConfiguration11
OBJECT-TYPE
Description of configuration no. #11
1.3.6.1.4.1.7501.1.2.114.6.1.1.14DisplayStringread-onlymandatory
besDisplayConfiguration12
OBJECT-TYPE
Description of configuration no. #12
1.3.6.1.4.1.7501.1.2.114.6.1.1.15DisplayStringread-onlymandatory
besDisplayConfiguration13
OBJECT-TYPE
Description of configuration no. #13
1.3.6.1.4.1.7501.1.2.114.6.1.1.16DisplayStringread-onlymandatory
besDisplayConfiguration14
OBJECT-TYPE
Description of configuration no. #14
1.3.6.1.4.1.7501.1.2.114.6.1.1.17DisplayStringread-onlymandatory
besDisplayConfiguration15
OBJECT-TYPE
Description of configuration no. #15
1.3.6.1.4.1.7501.1.2.114.6.1.1.18DisplayStringread-onlymandatory
besDisplayConfiguration16
OBJECT-TYPE
Description of configuration no. #16
1.3.6.1.4.1.7501.1.2.114.6.1.1.19DisplayStringread-onlymandatory
besDisplayPorts
OBJECT-IDENTITY
1.3.6.1.4.1.7501.1.2.114.56
besDisplayPortsTable
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.56.1not-accessiblemandatory
besDisplayPortsEntry
OBJECT-TYPE
1.3.6.1.4.1.7501.1.2.114.56.1.1not-accessiblemandatory
besDisplayPortsPortIndex
OBJECT-TYPE
Port index (1..besDisplayNumberOfPorts)
1.3.6.1.4.1.7501.1.2.114.56.1.1.1INTEGERread-onlymandatory
besDisplayPortsPortName
OBJECT-TYPE
Port name
1.3.6.1.4.1.7501.1.2.114.56.1.1.2DisplayStringread-onlymandatory
besDisplayPortsType
OBJECT-TYPE
Port type
1.3.6.1.4.1.7501.1.2.114.56.1.1.3PortTyperead-onlymandatory
besDisplayPortsLinkState
OBJECT-TYPE
Port link status
1.3.6.1.4.1.7501.1.2.114.56.1.1.4PortLinkStateread-onlymandatory
besDisplayPortsStatus
OBJECT-TYPE
Port status
1.3.6.1.4.1.7501.1.2.114.56.1.1.5PortStatusread-onlymandatory
besDisplayPortsDuplexMode
OBJECT-TYPE
Port duplex mode
1.3.6.1.4.1.7501.1.2.114.56.1.1.6PortDuplexModeread-onlymandatory
besDisplayPortsSpeed
OBJECT-TYPE
Port speed
1.3.6.1.4.1.7501.1.2.114.56.1.1.7PortSpeedread-onlymandatory
besDisplayPortsFlowControl
OBJECT-TYPE
Port speed
1.3.6.1.4.1.7501.1.2.114.56.1.1.8PortFlowControlread-onlymandatory
besDisplayPortsFiberTxDistance
OBJECT-TYPE
Port transmission distance in units of km (Fiber ports only)
1.3.6.1.4.1.7501.1.2.114.56.1.1.9INTEGERread-onlymandatory
besDisplayPortsFiberTxWavelen
OBJECT-TYPE
Port transmission wavelength in units of nm (Fiber ports only)
1.3.6.1.4.1.7501.1.2.114.56.1.1.10INTEGERread-onlymandatory
besDisplayPortsFiberRxWavelenMin
OBJECT-TYPE
Port minimum receive wavelength in units of nm (Fiber ports only)
1.3.6.1.4.1.7501.1.2.114.56.1.1.11INTEGERread-onlymandatory
besDisplayPortsFiberRxWavelenMax
OBJECT-TYPE
Port maximum receive wavelength in units of nm (Fiber ports only)
1.3.6.1.4.1.7501.1.2.114.56.1.1.12INTEGERread-onlymandatory
besDisplayPortsFiberSfpData
OBJECT-TYPE
Port SFP data text (Fiber ports only)
1.3.6.1.4.1.7501.1.2.114.56.1.1.13DisplayStringread-onlymandatory