ATEN-PE-CFG-STR
- Last updated
- 2013-10-31 11:10
- Organization
- ATEN
- Revisions
- 2013-10-31 11:10
- Namespace
- aten
- Source file
ATEN-PE-CFG-STR- Digest
sha256:713c0e1a72b4c1bc66e257564ca547b53c1e077058253f0b85c2063fbfd0c013
Description
ATEN PE MIB
Contact
Aten, Inc.
Imports
| From | Symbols |
|---|---|
| SNMP-USER-BASED-SM-MIB | KeyChange |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ATEN-PE-CFG-STR SNMP-FRAMEWORK-MIB SNMP-USER-BASED-SM-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| atenProducts OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1 | |||
| overip OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3 | |||
| poweroverip OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2 | |||
| pe OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2 | |||
| userManagement OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.1 | |||
| usrListTable OBJECT-TYPE A list of user. The number of user is given by the value of usrcfgNumber. | 1.3.6.1.4.1.21317.1.3.2.2.1.1 | not-accessible | current | |
| usrListEntry OBJECT-TYPE Status and parameter values for a pe8208 user. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1 | not-accessible | current | |
| usrIndex OBJECT-TYPE The value of usrIndex for the user. We have 1 administrator and 8 users. The index 9 will be the administrator. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.1 | INTEGER (1..9) | read-only | current |
| usrType OBJECT-TYPE The user's type. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.2 | INTEGER {administrator(1), user(2)} | read-only | current |
| usrName OBJECT-TYPE A textual string containing name of the user. string length: 1~16 | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.3 | DisplayString (SIZE(1..16)) | read-write | current |
| usrPassword OBJECT-TYPE A textual string containing password of the user. string length: 1~16 | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.4 | DisplayString (SIZE(1..16)) | read-write | current |
| usrPort1Auth OBJECT-TYPE Display or set this user's outlet 1 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.5 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort2Auth OBJECT-TYPE Display or set this user's outlet 2 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.6 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort3Auth OBJECT-TYPE Display or set this user's outlet 3 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.7 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort4Auth OBJECT-TYPE Display or set this user's outlet 4 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.8 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort5Auth OBJECT-TYPE Display or set this user's outlet 5 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.9 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort6Auth OBJECT-TYPE Dispaly or set this user's outlet 6 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.10 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort7Auth OBJECT-TYPE Display or set this user's outlet 7 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.11 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort8Auth OBJECT-TYPE Display or set this user's outlet 8 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.12 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort9Auth OBJECT-TYPE Display or set this user's outlet 9 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.13 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort10Auth OBJECT-TYPE Display or set this user's outlet 10 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.14 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort11Auth OBJECT-TYPE Display or set this user's outlet 11 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.15 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort12Auth OBJECT-TYPE Display or set this user's outlet 12 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.16 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort13Auth OBJECT-TYPE Display or set this user's outlet 13 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.17 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort14Auth OBJECT-TYPE Display or set this user's outlet 14 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.18 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort15Auth OBJECT-TYPE Display or set this user's outlet 15 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.19 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort16Auth OBJECT-TYPE Display or set this user's outlet 16 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.20 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort17Auth OBJECT-TYPE Display or set this user's outlet 17 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.21 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort18Auth OBJECT-TYPE Display or set this user's outlet 18 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.22 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort19Auth OBJECT-TYPE Display or set this user's outlet 19 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.23 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort20Auth OBJECT-TYPE Display or set this user's outlet 20 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.24 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort21Auth OBJECT-TYPE Display or set this user's outlet 21 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.25 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort22Auth OBJECT-TYPE Display or set this user's outlet 22 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.26 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort23Auth OBJECT-TYPE Display or set this user's outlet 23 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.27 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort24Auth OBJECT-TYPE Display or set this user's outlet 24 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.28 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort25Auth OBJECT-TYPE Display or set this user's outlet 25 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.29 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort26Auth OBJECT-TYPE Display or set this user's outlet 26 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.30 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort27Auth OBJECT-TYPE Display or set this user's outlet 27 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.31 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort28Auth OBJECT-TYPE Display or set this user's outlet 28 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.32 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort29Auth OBJECT-TYPE Display or set this user's outlet 29 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.33 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort30Auth OBJECT-TYPE Display or set this user's outlet 30 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.34 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort31Auth OBJECT-TYPE Display or set this user's outlet 31 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.35 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort32Auth OBJECT-TYPE Display or set this user's outlet 32 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.36 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort33Auth OBJECT-TYPE Display or set this user's outlet 33 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.37 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort34Auth OBJECT-TYPE Display or set this user's outlet 34 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.38 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort35Auth OBJECT-TYPE Display or set this user's outlet 35 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.39 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort36Auth OBJECT-TYPE Display or set this user's outlet 36 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.40 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort37Auth OBJECT-TYPE Display or set this user's outlet 37 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.41 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort38Auth OBJECT-TYPE Display or set this user's outlet 38 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.42 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort39Auth OBJECT-TYPE Display or set this user's outlet 39 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.43 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort40Auth OBJECT-TYPE Display or set this user's outlet 40 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.44 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort41Auth OBJECT-TYPE Display or set this user's outlet 41 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.45 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrPort42Auth OBJECT-TYPE Display or set this user's outlet 42 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.46 | INTEGER {disable(1), view(2), modify(3), not-support(4)} | read-write | current |
| usrEnable OBJECT-TYPE Display or set this user is enable or not | 1.3.6.1.4.1.21317.1.3.2.2.1.1.1.47 | INTEGER {disable(1), enable(2)} | read-write | current |
| control OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2 | |||
| device OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.1 | |||
| modelName OBJECT-TYPE Indicate PE device model name. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.1 | DisplayString | read-only | current |
| deviceName OBJECT-TYPE The name of PE device. string length: 1~39 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.2 | DisplayString | read-write | current |
| deviceValueTable OBJECT-TYPE Device value table. This table displays device's current, voltage, power and power dissipation. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3 | not-accessible | current | |
| deviceValueEntry OBJECT-TYPE Single deviceValue entry containing device info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1 | not-accessible | current | |
| deviceValueIndex OBJECT-TYPE Index of deviceValue. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.1 | INTEGER (1) | read-only | current |
| deviceCurrent OBJECT-TYPE Device electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.2 | DisplayString | read-only | current |
| deviceVoltage OBJECT-TYPE Device voltage value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.3 | DisplayString | read-only | current |
| devicePower OBJECT-TYPE Device power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.4 | DisplayString | read-only | current |
| devicePowerDissipation OBJECT-TYPE Device power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.5 | DisplayString | read-only | current |
| inputMaxVoltage OBJECT-TYPE Device input Voltage value. unit:(V) If the device does not support this OID, we show value 0. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.6 | INTEGER | read-only | current |
| inputMaxCurrent OBJECT-TYPE Device input Current value. unit:(A) If the device does not support this OID, we show value 0. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.7 | INTEGER | read-only | current |
| powerCapacity OBJECT-TYPE Device power Capacity value.unit:(VA) If the device does not support this OID, we show value 0. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.8 | INTEGER | read-only | current |
| devicePowerFactor OBJECT-TYPE Device power Factor value. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.9 | DisplayString | read-only | current |
| sensorValueTable OBJECT-TYPE Device's sensor value table. This table displays sensor's temperature, humidity and pressure. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4 | not-accessible | current | |
| sensorValueEntry OBJECT-TYPE Single device's sensor value entry containing device info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1 | not-accessible | current | |
| sensorValueIndex OBJECT-TYPE Index of sensor number. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.1 | INTEGER (1..6) | read-only | current |
| sensorTemperature OBJECT-TYPE Sensor's Temperature value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.2 | DisplayString | read-only | current |
| sensorHumidity OBJECT-TYPE Sensor's Humidity value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.3 | DisplayString | read-only | current |
| sensorPressure OBJECT-TYPE Sensor's Pressure value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.4 | DisplayString | read-only | current |
| sensorProperty OBJECT-TYPE Sensor's Property. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.5 | INTEGER {intake(1), exhaust(2), floor(3)} | read-only | current |
| deviceOutletStatusTable OBJECT-TYPE Device outlet status value table. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.5 | not-accessible | current | |
| deviceOutletStatusEntry OBJECT-TYPE Single deviceOutletStatus entry containing device info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1 | not-accessible | current | |
| deviceOutletStatusIndex OBJECT-TYPE Index of deviceOutletStatus | 1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.1 | INTEGER (1..30) | read-only | current |
| displayOutletStatus OBJECT-TYPE Display outlet status. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.2 | INTEGER {off(1), on(2), pending(3), fault(4), noauth(5), not-support(6), pop(7)} | read-only | current |
| deviceConfigTable OBJECT-TYPE Device configuration table | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6 | not-accessible | current | |
| deviceConfigEntry OBJECT-TYPE Single deviceConfig entry containing device info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1 | not-accessible | current | |
| deviceConfigIndex OBJECT-TYPE Index of deviceConfig | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.1 | INTEGER (1) | read-only | current |
| deviceMinCurMT OBJECT-TYPE Display or set device minimum electric current measurement threshold. Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.2 | INTEGER | read-write | current |
| deviceMaxCurMT OBJECT-TYPE Display or set device maximum electric current measurement threshold. Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.3 | INTEGER | read-write | current |
| deviceMinVolMT OBJECT-TYPE Display or set device minimum voltage measurement threshold. Exapmple: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.4 | INTEGER (900..2600 | -3000) | read-write | current |
| deviceMaxVolMT OBJECT-TYPE Display or set device maximum voltage measurement threshold. Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.5 | INTEGER (900..2600 | -3000) | read-write | current |
| deviceMinPMT OBJECT-TYPE Display or set device minimum power measurement threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.6 | INTEGER (0..99999 | -3000) | read-write | current |
| deviceMaxPMT OBJECT-TYPE Display or set device maximum power measurement threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.7 | INTEGER (0..99999 | -3000) | read-write | current |
| deviceMaxPDMT OBJECT-TYPE Display or set device maximum power dissipation measurement threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.8 | INTEGER (0..999990 | -3000) | read-write | current |
| deviceSensorTresholdTable OBJECT-TYPE Device environment value table | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7 | not-accessible | current | |
| deviceSensorTresholdEntry OBJECT-TYPE Device's sensor Environment entry containing sensor info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1 | not-accessible | current | |
| deviceSensorTresholdIndex OBJECT-TYPE Index of sensor number | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.1 | INTEGER (1..6) | read-only | current |
| sensorMinTempMT OBJECT-TYPE Display or set sensor minimum temperature measurement threshold. Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.2 | INTEGER (-200..600 | -3000) | read-write | current |
| sensorMaxTempMT OBJECT-TYPE Display or set sensor maximum temperature measurement threshold. Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.3 | INTEGER (-200..600 | -3000) | read-write | current |
| sensorMinHumMT OBJECT-TYPE Display or set sensor minimum humidity measurement threshold. Example: range 15.0 ~ 95.0 represents 150~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.4 | INTEGER (150..950 | -3000) | read-write | current |
| sensorMaxHumMT OBJECT-TYPE Display or set sensor maximum humidity measurement threshold. Example: range 15.0 ~ 95.0 represents 150~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.5 | INTEGER (150..950 | -3000) | read-write | current |
| sensorMinPressMT OBJECT-TYPE Display or set sensor minimum pressure measurement threshold. Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.6 | INTEGER (-2500..2500 | -3000) | read-write | current |
| sensorMaxPressMT OBJECT-TYPE Display or set sensor maximum pressure measurement threshold. Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.7 | INTEGER (-2500..2500 | -3000) | read-write | current |
| deviceOutletControl OBJECT-TYPE This function is used for all outlet ports control. Set off(1) to turn off for all outlet ports. Set on(2) to turn on for all outlet ports. Get this object always return nostatus(3), because there is no device status. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.8 | INTEGER {off(1), on(2), nostatus(3), not-support(4)} | read-write | current |
| deviceOutletReboot OBJECT-TYPE This function is used for all outlet ports to reboot. Only when outlet status is ON can do outlet reboot action to all ports. Set yes(2) to reboot all outlet ports. Get this object always return no(1). | 1.3.6.1.4.1.21317.1.3.2.2.2.1.9 | INTEGER {no(1), yes(2), not-support(4)} | read-write | current |
| switchable OBJECT-TYPE Outlet is switchable or not. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.10 | INTEGER {no(1), yes(2), mix(3)} | read-only | current |
| perportreading OBJECT-TYPE Outlet is per-port reading or not. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.11 | INTEGER {no(1), yes(2)} | read-only | current |
| sensornumber OBJECT-TYPE Sensor number. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.12 | INTEGER | read-only | current |
| outletnumber OBJECT-TYPE Outlet number. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.13 | INTEGER | read-only | current |
| banknumber OBJECT-TYPE Bank number. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.14 | INTEGER | read-only | current |
| doorSensor OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.1.16 | |||
| doorSensorStatus OBJECT-TYPE Display door sensor status. close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.16.1 | INTEGER {close(0), open(1), not-attached(2), not-support(4)} | read-only | current |
| doorSensorType OBJECT-TYPE Door Sensor Type Selection | 1.3.6.1.4.1.21317.1.3.2.2.2.1.16.2 | INTEGER {notinstalled(0), photo(1), inductiveproximity(2), reed(3)} | read-write | current |
| pop OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17 | |||
| enablePOPmode OBJECT-TYPE Enable/Disable POP mode. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17.1 | INTEGER {no(1), yes(2)} | read-write | current |
| popThreshold OBJECT-TYPE (-1)means default value same as Bank Max Current 16 A. Example: range 0.0~32.0 represents 0~320 You can define the POP threshold or set as default(-1) value. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17.2 | INTEGER | read-write | current |
| enableOutletPOPmode OBJECT-TYPE Enable/Disable Outlet POP mode. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17.3 | INTEGER {no(1), yes(2), not-support(3)} | read-write | current |
| enableLIFOPOPmode OBJECT-TYPE Enable/Disable LIFO POP mode. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17.4 | INTEGER {no(1), yes(2), not-support(3)} | read-write | current |
| enablePriorityPOPmode OBJECT-TYPE Enable/Disable Priority POP mode. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.17.5 | INTEGER {no(1), yes(2), not-support(3)} | read-write | current |
| cap OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18 | |||
| enableCAPmode OBJECT-TYPE Enable/Disable CAP mode. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18.1 | INTEGER {no(1), yes(2)} | read-write | current |
| outletCAPTable OBJECT-TYPE Outlet CAP table | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2 | not-accessible | current | |
| outletCAPEntry OBJECT-TYPE Outlet CAP entry containing CAP info. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1 | not-accessible | current | |
| outletCAPIndex OBJECT-TYPE Index of outlet's CAP configuration | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.1 | INTEGER (1..40) | read-only | current |
| outletCAPPriority OBJECT-TYPE Display or set the CAP Priority of outlet. Priority 0 means this outlet does not support this OID. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.2 | INTEGER (0..99) | read-write | current |
| outletInitMode OBJECT-TYPE choose outlet init mode you want. | 1.3.6.1.4.1.21317.1.3.2.2.2.1.19 | INTEGER {no-delaytime(1), delaytime(2), not-support(3)} | read-write | current |
| outlet OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.2 | |||
| outletValueTable OBJECT-TYPE Display total outlet value table | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1 | not-accessible | current | |
| outletValueEntry OBJECT-TYPE Single outletValue entry containing outlet info. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1 | not-accessible | current | |
| outletValueIndex OBJECT-TYPE Index of outlet number | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.1 | INTEGER (1..30) | read-only | current |
| outletCurrent OBJECT-TYPE Outlet electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.2 | DisplayString | read-only | current |
| outletVoltage OBJECT-TYPE Outlet voltage value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.3 | DisplayString | read-only | current |
| outletPower OBJECT-TYPE Outlet power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.4 | DisplayString | read-only | current |
| outletPowerDissipation OBJECT-TYPE Outlet power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.5 | DisplayString | read-only | current |
| outletMaxCurrent OBJECT-TYPE Outlet Max Current value. unit: (A). If the device does not support this OID, we show value 0. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.6 | INTEGER | read-only | current |
| outletPowerFactor OBJECT-TYPE Outlet Power Factor value. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.7 | DisplayString | read-only | current |
| outlet1Status OBJECT-TYPE Display and control outlet 1 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.2 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet2Status OBJECT-TYPE Display and control outlet 2 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.3 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet3Status OBJECT-TYPE Display and control outlet 3 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.4 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet4Status OBJECT-TYPE Display and control outlet 4 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.5 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet5Status OBJECT-TYPE Display and control outlet 5 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.6 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet6Status OBJECT-TYPE Display and control outlet 6 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.7 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet7Status OBJECT-TYPE Display and control outlet 7 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.8 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet8Status OBJECT-TYPE Display and control outlet 8 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.9 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outletConfigTable OBJECT-TYPE Outlet configuration table | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10 | not-accessible | current | |
| outletConfigEntry OBJECT-TYPE Outlet Config entry containing outlet info. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1 | not-accessible | current | |
| outletConfigIndex OBJECT-TYPE Index of outlet number | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.1 | INTEGER (1..30) | read-only | current |
| outletName OBJECT-TYPE Display or set the name of outlet. If the device does not support this OID, we show n/a. string length: 0~15 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.2 | DisplayString | read-write | current |
| outletConfirmation OBJECT-TYPE Display or set the confirmation of outlet. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.3 | INTEGER {no(1), yes(2), noauth(3), not-support(4)} | read-write | current |
| outletOnDelayTime OBJECT-TYPE Display or set the ON delay time of outlet. When this model does not support the OID, we show value -1. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.4 | INTEGER (0..999 | -1) | read-write | current |
| outletOffDelayTime OBJECT-TYPE Display or set the OFF delay time of outlet. When this model does not support the OID, we show value -1. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.5 | INTEGER (0..999 | -1) | read-write | current |
| outletShutdownMethod OBJECT-TYPE Display or set the shutdown mehtod of outlet. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.6 | INTEGER {kill-the-power(1), wake-on-lan(2), after-ac-back(3), not-support(4)} | read-write | current |
| outletMAC OBJECT-TYPE Display or set the MAC address of ShutdownMethod. If the device does not support this OID, we show n/a. string length: 12 | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.7 | DisplayString | read-write | current |
| outletMinCurMT OBJECT-TYPE Display or set the outlet minimum electric current measurment threshold. Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.8 | INTEGER | read-write | current |
| outletMaxCurMT OBJECT-TYPE Display or set the outlet maximum electric current measurment threshold. Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.9 | INTEGER | read-write | current |
| outletMinVolMT OBJECT-TYPE Display or set the outlet minimum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.10 | INTEGER (900..2600 | -3000 | -2000000) | read-write | current |
| outletMaxVolMT OBJECT-TYPE Display or set the outlet maximum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.11 | INTEGER (900..2600 | -3000 | -2000000) | read-write | current |
| outletMinPMT OBJECT-TYPE Display or set the outlet minimum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.12 | INTEGER (0..99999 | -3000 | -2000000) | read-write | current |
| outletMaxPMT OBJECT-TYPE Display or set the outlet maximum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.13 | INTEGER (0..99999 | -3000 | -2000000) | read-write | current |
| outletMaxPDMT OBJECT-TYPE Display or set the outlet maximum power dissipation measurment threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.14 | INTEGER (0..999990 | -3000 | -2000000) | read-write | current |
| outlet9Status OBJECT-TYPE Display and control outlet 9 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.11 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet10Status OBJECT-TYPE Display and control outlet 10 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.12 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet11Status OBJECT-TYPE Display and control outlet 11 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.13 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet12Status OBJECT-TYPE Display and control outlet 12 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.14 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet13Status OBJECT-TYPE Display and control outlet 13 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.15 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet14Status OBJECT-TYPE Display and control outlet 14 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.16 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet15Status OBJECT-TYPE Display and control outlet 15 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.17 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet16Status OBJECT-TYPE Display and control outlet 16 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.18 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet17Status OBJECT-TYPE Display and control outlet 17 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.19 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet18Status OBJECT-TYPE Display and control outlet 18 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.20 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet19Status OBJECT-TYPE Display and control outlet 19 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.21 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet20Status OBJECT-TYPE Display and control outlet 20 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.22 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet21Status OBJECT-TYPE Display and control outlet 21 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.23 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet22Status OBJECT-TYPE Display and control outlet 22 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.24 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet23Status OBJECT-TYPE Display and control outlet 23 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.25 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet24Status OBJECT-TYPE Display and control outlet 24 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.26 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet25Status OBJECT-TYPE Display and control outlet 25 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.27 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet26Status OBJECT-TYPE Display and control outlet 26 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.28 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet27Status OBJECT-TYPE Display and control outlet 27 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.29 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet28Status OBJECT-TYPE Display and control outlet 28 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.30 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet29Status OBJECT-TYPE Display and control outlet 29 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.31 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet30Status OBJECT-TYPE Display and control outlet 30 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.32 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet31Status OBJECT-TYPE Display and control outlet 31 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.33 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet32Status OBJECT-TYPE Display and control outlet 32 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.34 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet33Status OBJECT-TYPE Display and control outlet 33 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.35 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet34Status OBJECT-TYPE Display and control outlet 34 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.36 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet35Status OBJECT-TYPE Display and control outlet 35 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.37 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet36Status OBJECT-TYPE Display and control outlet 36 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.38 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet37Status OBJECT-TYPE Display and control outlet 37 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.39 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet38Status OBJECT-TYPE Display and control outlet 38 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.40 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet39Status OBJECT-TYPE Display and control outlet 39 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.41 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet40Status OBJECT-TYPE Display and control outlet 40 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.42 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet41Status OBJECT-TYPE Display and control outlet 41 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.43 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outlet42Status OBJECT-TYPE Display and control outlet 42 status. Can't set pending status. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.44 | INTEGER {off(1), on(2), pending(3), reboot(4), fault(5), noauth(6), not-support(7), pop(8)} | read-write | current |
| outletSwitchableTable OBJECT-TYPE | 1.3.6.1.4.1.21317.1.3.2.2.2.2.70 | not-accessible | current | |
| outletSwitchableEntry OBJECT-TYPE | 1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1 | not-accessible | current | |
| outletSwitchableIndex OBJECT-TYPE Index of outlet number. | 1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.1 | INTEGER (1..30) | read-only | current |
| outletSwitchable OBJECT-TYPE | 1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.2 | INTEGER {no(1), yes(2)} | read-only | current |
| bank OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.2.3 | |||
| breakerStatusTable OBJECT-TYPE Display total bank value table | 1.3.6.1.4.1.21317.1.3.2.2.2.3.1 | not-accessible | current | |
| breakerStatusEntry OBJECT-TYPE Single bankValue entry containing bank info. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1 | not-accessible | current | |
| breakerStatusIndex OBJECT-TYPE Index of breaker number. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.1 | INTEGER (1..30) | read-only | current |
| breakerStatus OBJECT-TYPE Breaker status. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.2 | INTEGER {off(1), on(2), not-support(3)} | read-only | current |
| bankValueTable OBJECT-TYPE Display total bank value table | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2 | not-accessible | current | |
| bankValueEntry OBJECT-TYPE Single bankValue entry containing bank info. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1 | not-accessible | current | |
| bankValueIndex OBJECT-TYPE Index of bank number | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.1 | INTEGER (1..30) | read-only | current |
| bankCurrent OBJECT-TYPE Bank electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.2 | DisplayString | read-only | current |
| bankVoltage OBJECT-TYPE Bank voltage value. We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can set 0 to clear the setting. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.3 | DisplayString | read-only | current |
| bankPower OBJECT-TYPE Bank power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.4 | DisplayString | read-only | current |
| bankPowerDissipation OBJECT-TYPE Bank power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.5 | DisplayString | read-only | current |
| bankMaxCurrent OBJECT-TYPE The Bank Max Current value. unit: (A) EC1000:0A~320A | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.6 | INTEGER | read-only | current |
| bankAttachStatus OBJECT-TYPE The status of Energy sensor Bank attached status. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.7 | INTEGER {noattached(1), attached(2), error(3), noexisted(4)} | read-only | current |
| bankPowerFactor OBJECT-TYPE Bank Power Factor value. If the device does not support this OID, it returns: not-support. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.8 | DisplayString | read-only | current |
| bankConfigTable OBJECT-TYPE Bank configuration table | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3 | not-accessible | current | |
| bankConfigEntry OBJECT-TYPE Bank Config entry containing Bank info. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1 | not-accessible | current | |
| bankConfigIndex OBJECT-TYPE Index of bank number | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.1 | INTEGER (1..30) | read-only | current |
| bankName OBJECT-TYPE Display or set the name of bank. When this model does not support the OID, we show n/a. string length: 0~15 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.2 | DisplayString | read-write | current |
| bankMinCurMT OBJECT-TYPE Display or set the outlet minimum electric current measurment threshold. Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.3 | INTEGER | read-write | current |
| bankMaxCurMT OBJECT-TYPE Display or set the outlet maximum electric current measurment threshold. Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.4 | INTEGER | read-write | current |
| bankMinVolMT OBJECT-TYPE Display or set the outlet minimum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.5 | INTEGER (900..2600 | -3000 | -2000000) | read-write | current |
| bankMaxVolMT OBJECT-TYPE Display or set the outlet maximum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.6 | INTEGER (900..2600 | -3000 | -2000000) | read-write | current |
| bankMinPMT OBJECT-TYPE Display or set the outlet minimum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.7 | INTEGER (0..99999 | -3000 | -2000000) | read-write | current |
| bankMaxPMT OBJECT-TYPE Display or set the outlet maximum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.8 | INTEGER (0..99999 | -3000 | -2000000) | read-write | current |
| bankMaxPDMT OBJECT-TYPE Display or set the outlet maximum power dissipation measurment threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not support this OID, it returns value -2000000. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.9 | INTEGER (0..999990 | -3000 | -2000000) | read-write | current |
| bankControlTable OBJECT-TYPE Bank Control table | 1.3.6.1.4.1.21317.1.3.2.2.2.3.4 | not-accessible | current | |
| bankControlEntry OBJECT-TYPE Bank control entry. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1 | not-accessible | current | |
| bankControlIndex OBJECT-TYPE Index of bank number | 1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.1 | INTEGER (1..4) | read-only | current |
| bankControlStatus OBJECT-TYPE This function is used for outlet control of bank. Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set reboot(3) to turn on for outlet control of bank. Get this object always return nostatus(3), because there is no bank status. | 1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.2 | INTEGER {off(1), on(2), reboot(3), nostatus(4), not-support(5)} | read-write | current |
| deviceManagement OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3 | |||
| config OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4 | |||
| deviceMAC OBJECT-TYPE Display device MAC address. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.1 | DisplayString | read-only | current |
| deviceIPv4 OBJECT-TYPE Display device IP address. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.2 | IpAddress | read-only | current |
| deviceFWversion OBJECT-TYPE Display device FW version. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.3 | DisplayString | read-only | current |
| dashBoard OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.4 | |||
| dashboardRow OBJECT-TYPE Display or set device's dashboard row number. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.4.1 | INTEGER (1..26) | read-write | current |
| dashboardColumn OBJECT-TYPE Display or set device's dashboard column number. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.4.2 | INTEGER (1..26) | read-write | current |
| dashboardRackName OBJECT-TYPE Display or set device's dashboard rack name. string length: 1~32 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.4.3 | DisplayString | read-write | current |
| servicePorts OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.5 | |||
| httpPort OBJECT-TYPE Display or set the HTTP port of PE device. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.5.1 | INTEGER (1..65535) | read-write | current |
| httpsPort OBJECT-TYPE Display or set the HTTPs port of PE device. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.5.2 | INTEGER (1..65535) | read-write | current |
| httpsOnlyEnable OBJECT-TYPE Enable to use Webpage HTTPs only or disable to use Webpage HTTP/HTTPs | 1.3.6.1.4.1.21317.1.3.2.2.3.4.5.3 | INTEGER {yes(1), no(2)} | read-write | current |
| ipv4config OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6 | |||
| staticIPEnabled OBJECT-TYPE Display or set IPv4 address automatically or not | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.1 | INTEGER {no(1), yes(2)} | read-write | current |
| fixedIPv4 OBJECT-TYPE Display or set fixed IPv4 address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.2 | IpAddress | read-write | current |
| subnetMask OBJECT-TYPE Display or set subnet mask address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.3 | IpAddress | read-write | current |
| gateway OBJECT-TYPE Display or set gateway address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.4 | IpAddress | read-write | current |
| staticDNSEnabled OBJECT-TYPE Display or set DNS address automatically or not | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.5 | INTEGER {no(1), yes(2)} | read-write | current |
| dnsPreferIPv4 OBJECT-TYPE Display or set prefer DNS address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.6 | IpAddress | read-write | current |
| dnsAlternateIPv4 OBJECT-TYPE Display or set alternate DNS address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.6.7 | IpAddress | read-write | current |
| eventNotification OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7 | |||
| devicesnmp OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1 | |||
| trapEnabled OBJECT-TYPE Indicates if this trap entry is enabled or not. You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.1 | INTEGER {no(1), yes(2)} | read-write | current |
| trapVersion OBJECT-TYPE Choose SNMP Trap version to send trap. You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string first, when choosing snmpv1/v2c. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.2 | INTEGER {v1(1), v2c(2), v3(3)} | read-write | current |
| snmpTrapTable OBJECT-TYPE PE SNMP agent trap setup table. If users want to use trap, they must set enable trap, ip and community first. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3 | not-accessible | current | |
| snmpTrapEntry OBJECT-TYPE Single trap entry containing trap receiver info. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1 | not-accessible | current | |
| trapReceiverNumber OBJECT-TYPE Index of trap receiver | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.1 | INTEGER (1..2) | read-only | current |
| trapReceiverIPAddress OBJECT-TYPE Trap receiver IP address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.2 | IpAddress | read-write | current |
| trapPort OBJECT-TYPE NMS trap port to be used by agent to send trap | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.3 | INTEGER (1..65535) | read-write | current |
| trapCommunity OBJECT-TYPE If use SNMPv1/v2c to receive trap should set this Community string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.4 | DisplayString (SIZE(0..20)) | read-write | current |
| trapUsername OBJECT-TYPE If use SNMPv3 to receive trap should set this string. NOTE: Input string as /empty to set this object to NULL. MAX string length: 20 | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.5 | DisplayString (SIZE(0..20)) | read-write | current |
| trapAuthpassword OBJECT-TYPE If use SNMPv3 to receive trap should set this string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.6 | DisplayString (SIZE(8..20)) | read-write | current |
| trapPrivpassword OBJECT-TYPE If use SNMPv3 to receive trap should set this string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.7 | DisplayString (SIZE(8..20)) | read-write | current |
| syslog OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2 | |||
| sysLogServerEnabled OBJECT-TYPE Display or set syslog server address automatically or not | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.1 | INTEGER {no(1), yes(2)} | read-write | current |
| sysLogServerIPv4 OBJECT-TYPE Display or set syslog server address | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.2 | IpAddress | read-write | current |
| sysLogServerPort OBJECT-TYPE Display or set syslog server port | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.3 | INTEGER (1..65535) | read-write | current |
| smtp OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3 | |||
| smtpServerEnabled OBJECT-TYPE Display or set SMTP server enable status. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.1 | INTEGER {no(1), yes(2)} | read-write | current |
| smtpServerName OBJECT-TYPE Display or set a SMTP server name. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.2 | DisplayString | read-write | current |
| smtpAuthEnabled OBJECT-TYPE Display or set authentication of SMTP server. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.3 | INTEGER {no(1), yes(2)} | read-write | current |
| smtpAccountName OBJECT-TYPE Display or set a user's name of SMTP server. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.4 | DisplayString | read-write | current |
| smtpAccountPwd OBJECT-TYPE Display or set a user's password of SMTP server. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.5 | DisplayString | read-write | current |
| smtpMailFrom OBJECT-TYPE Display or set a mail of SMTP server. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.6 | DisplayString | read-write | current |
| smtpMailTo OBJECT-TYPE Display or set a mail of SMTP server. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.7 | DisplayString | read-write | current |
| configurationNotification OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9 | |||
| configurationNotifyEnabled OBJECT-TYPE | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9.1 | INTEGER {no(1), yes(2)} | read-write | current |
| dateTime OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8 | |||
| timeZone OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1 | |||
| timeZoneSetting OBJECT-TYPE Display or set the time zone of PE device. (0) [GMT-12:00] Eniwetok Kwajalein (1) [GMT-11:00] Midway Island Samoa (2) [GMT-10:00] Hawaii (3) [GMT-09:00] Alaska (4) [GMT-08:00] Pacific Time (US & Canada); Tijuana (5) [GMT-07:00] Mountain Time (US & Canada) (6) [GMT-07:00] Arizona (7) [GMT-06:00] Central Time (US & Canada) (8) [GMT-06:00] Mexico City (9) [GMT-06:00] Saskatchewan (10)[GMT-06:00] Central America (11)[GMT-05:00] Eastern Time (US & Canada) (12)[GMT-05:00] Indiana (East) (13)[GMT-05:00] Bogota Lima Quito (14)[GMT-04:00] Atlantic Time (Canada) (15)[GMT-04:00] Caracas La Paz (16)[GMT-04:00] Santiago (17)[GMT-03:30] Newfoundland (18)[GMT-03:00] Buenos Aires Georgetown (19)[GMT-03:00] Brasilia (20)[GMT-03:00] Greenland (21)[GMT-02:00] Mid-Atlantic (22)[GMT-01:00] Azores (23)[GMT-01:00] Cape Verde Is (24)[GMT] Casablanca Monrovia (25)[GMT] Greenwich Mean Time: Dublin Edinburgh Lisbon London (26)[GMT+01:00] Amsterdam Copenhagen Madrid Paris Vilnius (27)[GMT+01:00] West Central Africa (28)[GMT+01:00] Belgrade Sarajevo Skopje Sofija Zagreb (29)[GMT+01:00] Bratislava Budapest Ljubljana Prague Warsaw (30)[GMT+01:00] Brussels Berlin Bern Rome Stockholm Vienna (31)[GMT+02:00] Cairo (32)[GMT+02:00] Harare Pretoria (33)[GMT+02:00] Jerusalem (34)[GMT+02:00] Bucharest (35)[GMT+02:00] Helsinki Riga Tallinn (36)[GMT+02:00] Athens Istanbul Minsk (37)[GMT+03:00] Kuwait Riyadh (38)[GMT+03:00] Nairobi (39)[GMT+03:00] Baghdad (40)[GMT+03:00] Moscow St. Petersburg Volgograd (41)[GMT+03:30] Tehran (42)[GMT+04:00] Abu Dhabi Muscat (43)[GMT+04:00] Baku Tbilisi Yerevan (44)[GMT+04:30] Kabul (45)[GMT+05:00] Islamabad Karachi Tashkent (46)[GMT+05:00] Ekaterinburg (47)[GMT+05:30] Calcutta Chennai Mumbai New Delhi (48)[GMT+05:45] Kathmandu (49)[GMT+06:00] Astana Dhaka (50)[GMT+06:00] Sri Jayawardenepura (51)[GMT+06:00] Almaty Novosibirsk (52)[GMT+06:30] Rangoon (53)[GMT+07:00] Bangkok Hanoi Jakarta (54)[GMT+07:00] Krasnoyarsk (55)[GMT+08:00] Beijing Chongqing Hong Kong Urumqi (56)[GMT+08:00] Perth (57)[GMT+08:00] Kuala Lumpur Singapore (58)[GMT+08:00] Taipei (59)[GMT+08:00] Irkutsk Ulaan Bataar (60)[GMT+09:00] Osaka Sapporo Tokyo (61)[GMT+09:00] Seoul (62)[GMT+09:00] Yakutsk (63)[GMT+09:30] Darwin (64)[GMT+09:30] Adelaide (65)[GMT+10:00] Canberra Melbourne Sydney (66)[GMT+10:00] Brisbane (67)[GMT+10:00] Guam Port Moresby (68)[GMT+10:00] Hobart (69)[GMT+10:00] Vladivostok (70)[GMT+11:00] Magadan Solomon Is New Caledonia (71)[GMT+12:00] Fiji Kamchatka Marshall Is. (72)[GMT+12:00] Auckland Wellington (73)[GMT+13:00] Nuku'alofa | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1.1 | INTEGER | read-write | current |
| dstEnabled OBJECT-TYPE Display or set daylight savings time . | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1.2 | INTEGER {no(1), yes(2)} | read-write | current |
| manualInput OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2 | |||
| dateSetting OBJECT-TYPE Display or set date in a manual way.(This is Greenwich Mean Time, GMT) string length: 10 This value format must match the following form: YYYY-MM-DD ex. 2011-01-01 Note: range of year: 2000-2099 range of month: 01-12 range of day: 01-31 | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2.1 | DisplayString | read-write | current |
| timeSetting OBJECT-TYPE Display or set time in a manual way.(This is Greenwich Mean Time, GMT) string length: 8 This value format must match the following form: HH:MM:SS ex. 02:02:02 Note: range of hour: 00-24 range of minute: 00-60 range of second: 00-60 | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2.2 | DisplayString | read-write | current |
| networkTime OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3 | |||
| autoAdjustEnabled OBJECT-TYPE Display or set date time useing auto adjustment way. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.1 | INTEGER {no(1), yes(2)} | read-write | current |
| preferNTP OBJECT-TYPE Display or set prefer NTP server. AU | ntp1.cs.mu.OZ.AU(0), AU | ntp0.cs.mu.OZ.AU(1), BE | ntp2.oma.be(2), BE | ntp1.oma.be(3), BR | ntps1.pads.ufrj.br(4), CH | swisstime.ethz.ch(5), CL | ntp.shoa.cl(6), CZ | ntp.nic.cz(7), DE | ntp.stairweb.de(8), DE | ntps1-0.cs.tu-berlin.de(9), DE | ptbtime1.ptb.de(10), DE | ntp1.fau.de(11), DE | ptbtime2.ptb.de(12), DE | time1.one4vision.de(13), DE | rustime01.rus.uni-stuttgart.de(14), DE | ntp.probe-networks.de(15), DE | ntp2.fau.de(16), ES | hora.roa.es(17), HK | stdtime.gov.hk(18), IE | ntp-galway.hea.net(19), IT | ntp1.inrim.it(20), IT | ntp2.inrim.it(21), JP | clock.tl.fukuoka-u.ac.jp(22), JP | ntp.nict.jp(23), JP | clock.nc.fukuoka-u.ac.jp(24), KR | ntp.xbsd.kr(25), MX | cronos.cenam.mx(26), NL | ntp0.nl.uu.net(27), NL | ntp1.nl.uu.net(28), NL | ntp.remco.org(29), NL | ntp0.nl.net(30), PL | vega.cbk.poznan.pl(31), PL | ntp.ntp-servers.com(32), RO | ntp3.usv.ro(33), RO | ntp2.usv.ro(34), RU | ntp1.vniiftri.ru; ntp1.imvp.ru(35), RU | ntp2.vniiftri.ru; ntp2.imvp.ru(36), SE | ntp1.mmo.netnod.se(37), SE | ntp1.sth.netnod.se(38), SE | ntp2.mmo.netnod.se(39), SE | ntp2.sth.netnod.se(40), SE | time2.stupi.se(41), SE | ntp1.sp.se(42), SE | timehost.lysator.liu.se(43), SI | ntp.mostovna.com(44), US CA | timekeeper.isi.edu(45), US CA | clock.sjc.he.net(46), US CA | nist1.symmetricom.com(47), US CA | clock.via.net(48), US CA | nist1.aol-ca.truetime.com(49), US CA | clock.isc.org(50), US CA | clepsydra.dec.com(51), US CA | gps.layer42.net(52), US CA | time.no-such-agency.net(53), US CA | nist1-sj.WiTime.net(54), US CA | clock.fmt.he.net(55), US CO | time-b.timefreq.bldrdoc.gov(56), US CO | time-a.timefreq.bldrdoc.gov(57), US CO | utcnist.colorado.edu(58), US CO | time-c.timefreq.bldrdoc.gov(59), US DE | rackety.udel.edu(60), US DE | mizbeaver.udel.edu(61), US GA | nist1.columbiacountyga.gov(62), US IL | ntp.your.org(63), US MA | bonehed.lcs.mit.edu(64), US MA | time.keneli.org(65), US MA | ntp0.broad.mit.edu(66), US MD | time-a.nist.gov(67), US MD | time-b.nist.gov(68), US MI | nist.netservicesgroup.com(69), US NY | nist1-ny.WiTime.net(70), US NY | clock.nyc.he.net(71), US UT | time.xmission.com(72), US VA | nist1-dc.WiTime.net(73), US VA | nist1.aol-va.truetime.com(74), US WA | time-nw.nist.gov(75), FR | utp.univ-lyon1.fr(76), FR | ntp-sop.inria.fr(77), FR | ntp.tuxfamily.net(78), UK | bear.zoo.bt.co.uk(79) | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.2 | INTEGER | read-write | current |
| preferServerIPenable OBJECT-TYPE Enable or disable prefer custom server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.3 | INTEGER {no(1), yes(2)} | read-write | current |
| preferNTPIp OBJECT-TYPE Display or set prefer NTP server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.4 | IpAddress | read-write | current |
| alternateNtpEnabled OBJECT-TYPE Display or set date time using alternate NTP server. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.5 | INTEGER {no(1), yes(2)} | read-write | current |
| alternateNtp OBJECT-TYPE Display or set alternative NTP server. AU | ntp1.cs.mu.OZ.AU(0), AU | ntp0.cs.mu.OZ.AU(1), BE | ntp2.oma.be(2), BE | ntp1.oma.be(3), BR | ntps1.pads.ufrj.br(4), CH | swisstime.ethz.ch(5), CL | ntp.shoa.cl(6), CZ | ntp.nic.cz(7), DE | ntp.stairweb.de(8), DE | ntps1-0.cs.tu-berlin.de(9), DE | ptbtime1.ptb.de(10), DE | ntp1.fau.de(11), DE | ptbtime2.ptb.de(12), DE | time1.one4vision.de(13), DE | rustime01.rus.uni-stuttgart.de(14), DE | ntp.probe-networks.de(15), DE | ntp2.fau.de(16), ES | hora.roa.es(17), HK | stdtime.gov.hk(18), IE | ntp-galway.hea.net(19), IT | ntp1.inrim.it(20), IT | ntp2.inrim.it(21), JP | clock.tl.fukuoka-u.ac.jp(22), JP | ntp.nict.jp(23), JP | clock.nc.fukuoka-u.ac.jp(24), KR | ntp.xbsd.kr(25), MX | cronos.cenam.mx(26), NL | ntp0.nl.uu.net(27), NL | ntp1.nl.uu.net(28), NL | ntp.remco.org(29), NL | ntp0.nl.net(30), PL | vega.cbk.poznan.pl(31), PL | ntp.ntp-servers.com(32), RO | ntp3.usv.ro(33), RO | ntp2.usv.ro(34), RU | ntp1.vniiftri.ru; ntp1.imvp.ru(35), RU | ntp2.vniiftri.ru; ntp2.imvp.ru(36), SE | ntp1.mmo.netnod.se(37), SE | ntp1.sth.netnod.se(38), SE | ntp2.mmo.netnod.se(39), SE | ntp2.sth.netnod.se(40), SE | time2.stupi.se(41), SE | ntp1.sp.se(42), SE | timehost.lysator.liu.se(43), SI | ntp.mostovna.com(44), US CA | timekeeper.isi.edu(45), US CA | clock.sjc.he.net(46), US CA | nist1.symmetricom.com(47), US CA | clock.via.net(48), US CA | nist1.aol-ca.truetime.com(49), US CA | clock.isc.org(50), US CA | clepsydra.dec.com(51), US CA | gps.layer42.net(52), US CA | time.no-such-agency.net(53), US CA | nist1-sj.WiTime.net(54), US CA | clock.fmt.he.net(55), US CO | time-b.timefreq.bldrdoc.gov(56), US CO | time-a.timefreq.bldrdoc.gov(57), US CO | utcnist.colorado.edu(58), US CO | time-c.timefreq.bldrdoc.gov(59), US DE | rackety.udel.edu(60), US DE | mizbeaver.udel.edu(61), US GA | nist1.columbiacountyga.gov(62), US IL | ntp.your.org(63), US MA | bonehed.lcs.mit.edu(64), US MA | time.keneli.org(65), US MA | ntp0.broad.mit.edu(66), US MD | time-a.nist.gov(67), US MD | time-b.nist.gov(68), US MI | nist.netservicesgroup.com(69), US NY | nist1-ny.WiTime.net(70), US NY | clock.nyc.he.net(71), US UT | time.xmission.com(72), US VA | nist1-dc.WiTime.net(73), US VA | nist1.aol-va.truetime.com(74), US WA | time-nw.nist.gov(75), FR | utp.univ-lyon1.fr(76), FR | ntp-sop.inria.fr(77), FR | ntp.tuxfamily.net(78), UK | bear.zoo.bt.co.uk(79) | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.6 | INTEGER | read-write | current |
| alternateServerIPenable OBJECT-TYPE Enable or disable alternate custom server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.7 | INTEGER {no(1), yes(2)} | read-write | current |
| alternateNtpIp OBJECT-TYPE Display or set alternative NTP server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.8 | IpAddress | read-write | current |
| adjustTimeEveryDays OBJECT-TYPE Display or set frequency of adjustment in days. | 1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.9 | INTEGER | read-write | current |
| devicesecurity OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5 | |||
| loginFailures OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.1 | |||
| loginAllowTimes OBJECT-TYPE Display or set time of login faliure. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.1.1 | INTEGER (1..99) | read-write | current |
| loginTimeOut OBJECT-TYPE Display or set login time out. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.1.2 | INTEGER (1..240) | read-write | current |
| workingMode OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.2 | |||
| icmpEnabled OBJECT-TYPE Display or set status of ICMP. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.2.1 | INTEGER {no(1), yes(2)} | read-write | current |
| accountPolicy OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3 | |||
| minUserNameLen OBJECT-TYPE Display or set minimum length of user name. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.1 | INTEGER (1..16) | read-write | current |
| minUserPwdLen OBJECT-TYPE Display or set minimum length of user password. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.2 | INTEGER (1..16) | read-write | current |
| upperCaseEnabled OBJECT-TYPE Display or set one upper case rule in user password. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.3 | INTEGER {no(1), yes(2)} | read-write | current |
| lowerCaseEnabled OBJECT-TYPE Display or set one lower case rule in user password. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.4 | INTEGER {no(1), yes(2)} | read-write | current |
| numberEnabled OBJECT-TYPE Display or set one number rule in user password. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.5 | INTEGER {no(1), yes(2)} | read-write | current |
| disableDuplicateLogin OBJECT-TYPE Display or set status of disabled duplicate login rule. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.3.6 | INTEGER {no(1), yes(2)} | read-write | current |
| loginRestriction OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4 | |||
| loginString OBJECT-TYPE Display or set a login string. string length: 0~32 NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.1 | DisplayString | read-write | current |
| ipFilter OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2 | |||
| ipFilterEnabled OBJECT-TYPE Display or set status of ip filter. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.1 | INTEGER {no(1), yes(2)} | read-write | current |
| ipFilterRule OBJECT-TYPE Display or set status of ip filter rule. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.2 | INTEGER {include(1), exclude(2)} | read-write | current |
| ipFilterTable OBJECT-TYPE A list of restricted ip. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3 | not-accessible | current | |
| ipFilterEntry OBJECT-TYPE Status and parameter values for a PE's restricted IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1 | not-accessible | current | |
| ipFilterIndex OBJECT-TYPE The value of index for the ip filter. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.1 | INTEGER (1..5) | read-only | current |
| ipFilterFrom OBJECT-TYPE A set of restricted ip. ex. 192.168.0.1 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.2 | IpAddress | read-write | current |
| ipFilterTo OBJECT-TYPE A set of restricted ip. ex. 192.168.0.255 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.3 | IpAddress | read-write | current |
| macFilter OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3 | |||
| macFilterEnabled OBJECT-TYPE Display or set status of mac filter. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.1 | INTEGER {no(1), yes(2)} | read-write | current |
| macFilterRule OBJECT-TYPE Display or set status of mac filter rule. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.2 | INTEGER {include(1), exclude(2)} | read-write | current |
| macFilterTable OBJECT-TYPE A list of restricted mac. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3 | not-accessible | current | |
| macFilterEntry OBJECT-TYPE Status and parameter values for a PE's restricted MAC. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1 | not-accessible | current | |
| macFilterIndex OBJECT-TYPE The value of index for the mac filter. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.1 | INTEGER (1..5) | read-only | current |
| macFilterSet OBJECT-TYPE A set of restricted mac. string length: 12 ex. 004854655511 Note: Users must follow in order to set the MAC address. Note: To clear the settings to set the MAC 000000000000 | 1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.2 | DisplayString | read-write | current |
| authentication OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5 | |||
| radius OBJECT-IDENTITY | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1 | |||
| radiusEnabled OBJECT-TYPE Display or set status of RADIUS server. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.1 | INTEGER {no(1), yes(2)} | read-write | current |
| preferRadiusIp OBJECT-TYPE Display or set prefer RADIUS server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.2 | IpAddress | read-write | current |
| preferRadiusPort OBJECT-TYPE Display or set prefer RADIUS server port. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.3 | INTEGER (1..65535) | read-write | current |
| alternateRadiusIp OBJECT-TYPE Display or set alternative RADIUS server IP. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.4 | IpAddress | read-write | current |
| alternateRadiusPort OBJECT-TYPE Display or set alternative RADIUS server port. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.5 | INTEGER (1..65535) | read-write | current |
| radiusTimeOut OBJECT-TYPE Display or set time out of authentication using RADIUS server. The unit is sec. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.6 | INTEGER (1..60) | read-write | current |
| radiusRetry OBJECT-TYPE Display or set retry times of authentication using RADIUS server. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.7 | INTEGER (0..10) | read-write | current |
| radiusSecret OBJECT-TYPE Display or set shared secret of RADIUS server. string length: 6~15 At least 6 characters. NOTE: Input string as /empty to set this object to NULL. | 1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.8 | DisplayString | read-write | current |
| rebootDevice OBJECT-TYPE Reboot PE Device | 1.3.6.1.4.1.21317.1.3.2.2.6 | INTEGER {no(1), yes(2)} | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| configurationNotifyTrapMSG NOTIFICATION-TYPE | 1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9.2 | current |
| customTrapMSG NOTIFICATION-TYPE Display custom trap message. | 1.3.6.1.4.1.21317.1.3.2.2.5 | current |