MIBs Depot

AT-PLUGGABLE-DIAGNOSTICS-MIB

Registered at
1.3.6.1.4.1.207.8.4.4.3.28
Last updated
2015-07-17 00:00
Organization
Allied Telesis, Inc
Revisions
2015-07-17 00:00
Namespace
allied
Source file
AT-PLUGGABLE-DIAGNOSTICS-MIB
Digest
sha256:e0ffbdffb31b636d54f4dc4c7863d538ae1800ca73b9e518df62a2fd876fe4a8

Description

The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.

Contact

http://www.alliedtelesis.com

Imports

FromSymbols
AT-SMI-MIBDisplayStringUnsized
AT-SYSINFO-MIBsysinfo
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

AT-PLUGGABLE-DIAGNOSTICS-MIB
AT-SMI-MIB
AT-SYSINFO-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
atPluggableDiagTable
OBJECT-IDENTITY
1.3.6.1.4.1.207.8.4.4.3.28.1
atPluggableDiagTempTable
OBJECT-TYPE
A table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.1not-accessiblecurrent
atPluggableDiagTempEntry
OBJECT-TYPE
The information about various temperature parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1not-accessiblecurrent
atPluggableDiagTempIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagTempChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagTempStatusReading
OBJECT-TYPE
The current temperature status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3Integer32read-onlycurrent
atPluggableDiagTempCurrentAlarm
OBJECT-TYPE
The current temperature alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4OCTET STRINGread-onlycurrent
atPluggableDiagTempAlarmMax
OBJECT-TYPE
The maximum temperature alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5Integer32read-onlycurrent
atPluggableDiagTempAlarmMin
OBJECT-TYPE
The minimum temperature alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6Integer32read-onlycurrent
atPluggableDiagTempCurrentWarning
OBJECT-TYPE
The current temperature warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7OCTET STRINGread-onlycurrent
atPluggableDiagTempWarningMax
OBJECT-TYPE
The maximum temperature warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8Integer32read-onlycurrent
atPluggableDiagTempWarningMin
OBJECT-TYPE
The minimum temperature warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9Integer32read-onlycurrent
atPluggableDiagVccTable
OBJECT-TYPE
A table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.2not-accessiblecurrent
atPluggableDiagVccEntry
OBJECT-TYPE
The information about various Voltage (Vcc) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1not-accessiblecurrent
atPluggableDiagVccIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagVccChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagVccStatusReading
OBJECT-TYPE
The current Voltage (Vcc) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3Integer32read-onlycurrent
atPluggableDiagVccCurrentAlarm
OBJECT-TYPE
The current Voltage (Vcc) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4OCTET STRINGread-onlycurrent
atPluggableDiagVccAlarmMax
OBJECT-TYPE
The maximum Voltage (Vcc) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5Integer32read-onlycurrent
atPluggableDiagVccAlarmMin
OBJECT-TYPE
The minimum Voltage (Vcc) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6Integer32read-onlycurrent
atPluggableDiagVccCurrentWarning
OBJECT-TYPE
The current Voltage (Vcc) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7OCTET STRINGread-onlycurrent
atPluggableDiagVccWarningMax
OBJECT-TYPE
The maximum Voltage (Vcc) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8Integer32read-onlycurrent
atPluggableDiagVccWarningMin
OBJECT-TYPE
The minimum Voltage (Vcc) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9Integer32read-onlycurrent
atPluggableDiagTxBiasTable
OBJECT-TYPE
A table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.3not-accessiblecurrent
atPluggableDiagTxBiasEntry
OBJECT-TYPE
The information about various Tx Bias Current (mA) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1not-accessiblecurrent
atPluggableDiagTxBiasIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagTxBiasChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagTxBiasStatusReading
OBJECT-TYPE
The current Tx Bias (mA) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3Integer32read-onlycurrent
atPluggableDiagTxBiasCurrentAlarm
OBJECT-TYPE
The current Tx Bias (mA) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4OCTET STRINGread-onlycurrent
atPluggableDiagTxBiasAlarmMax
OBJECT-TYPE
The maximum Tx Bias (mA) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5Integer32read-onlycurrent
atPluggableDiagTxBiasAlarmMin
OBJECT-TYPE
The minimum Tx Bias (mA) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6Integer32read-onlycurrent
atPluggableDiagTxBiasCurrentWarning
OBJECT-TYPE
The current Tx Bias (mA) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7OCTET STRINGread-onlycurrent
atPluggableDiagTxBiasWarningMax
OBJECT-TYPE
The maximum Tx Bias (mA) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8Integer32read-onlycurrent
atPluggableDiagTxBiasWarningMin
OBJECT-TYPE
The minimum Tx Bias (mA) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9Integer32read-onlycurrent
atPluggableDiagTxPowerTable
OBJECT-TYPE
A table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.4not-accessiblecurrent
atPluggableDiagTxPowerEntry
OBJECT-TYPE
The information about various Tx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1not-accessiblecurrent
atPluggableDiagTxPowerIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagTxPowerChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagTxPowerStatusReading
OBJECT-TYPE
The current Tx Power (mW) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3Integer32read-onlycurrent
atPluggableDiagTxPowerCurrentAlarm
OBJECT-TYPE
The current Tx Power (mW) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4OCTET STRINGread-onlycurrent
atPluggableDiagTxPowerAlarmMax
OBJECT-TYPE
The maximum Tx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5Integer32read-onlycurrent
atPluggableDiagTxPowerAlarmMin
OBJECT-TYPE
The minimum Tx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6Integer32read-onlycurrent
atPluggableDiagTxPowerCurrentWarning
OBJECT-TYPE
The current Tx Power (mW) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7OCTET STRINGread-onlycurrent
atPluggableDiagTxPowerWarningMax
OBJECT-TYPE
The maximum Tx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8Integer32read-onlycurrent
atPluggableDiagTxPowerWarningMin
OBJECT-TYPE
The minimum Tx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9Integer32read-onlycurrent
atPluggableDiagRxPowerTable
OBJECT-TYPE
A table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.5not-accessiblecurrent
atPluggableDiagRxPowerEntry
OBJECT-TYPE
The information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1not-accessiblecurrent
atPluggableDiagRxPowerIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagRxPowerChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagRxPowerStatusReading
OBJECT-TYPE
The current Rx Power (mW) status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3Integer32read-onlycurrent
atPluggableDiagRxPowerCurrentAlarm
OBJECT-TYPE
The current Rx Power (mW) alarm reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4OCTET STRINGread-onlycurrent
atPluggableDiagRxPowerAlarmMax
OBJECT-TYPE
The maximum Rx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5Integer32read-onlycurrent
atPluggableDiagRxPowerAlarmMin
OBJECT-TYPE
The minimum Rx Power (mW) alarm threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6Integer32read-onlycurrent
atPluggableDiagRxPowerCurrentWarning
OBJECT-TYPE
The current Rx Power (mW) warnings.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7OCTET STRINGread-onlycurrent
atPluggableDiagRxPowerWarningMax
OBJECT-TYPE
The maximum Rx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8Integer32read-onlycurrent
atPluggableDiagRxPowerWarningMin
OBJECT-TYPE
The minimum Rx Power (mW) warning threshold value.
1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9Integer32read-onlycurrent
atPluggableDiagRxLosTable
OBJECT-TYPE
A table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
1.3.6.1.4.1.207.8.4.4.3.28.1.6not-accessiblecurrent
atPluggableDiagRxLosEntry
OBJECT-TYPE
The information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1not-accessiblecurrent
atPluggableDiagRxLosIfIndex
OBJECT-TYPE
The ifindex of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1InterfaceIndexnot-accessiblecurrent
atPluggableDiagRxLosChannel
OBJECT-TYPE
The channel number of the pluggable.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2Integer32 (1..16)not-accessiblecurrent
atPluggableDiagRxLosStatusReading
OBJECT-TYPE
The current Rx Los status reading.
1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3OCTET STRINGread-onlycurrent