AT-FIBER-MONITORING-MIB
- Registered at
- 1.3.6.1.4.1.207.8.4.4.3.27
- Last updated
- 2015-09-08 00:00
- Organization
- Allied Telesis, Inc
- Revisions
- 2015-09-08 00:00
- Namespace
- allied
- Source file
AT-FIBER-MONITORING-MIB- Digest
sha256:c343046dfa7748b4211c1d7c5e67fdd80f63237f04f18e4179b117a1a657958c
Description
This MIB contains managed objects definition and notification definitions for AT Fiber Monitoring feature.
Contact
http://www.alliedtelesis.com
Imports
| From | Symbols |
|---|---|
| AT-SYSINFO-MIB | sysinfo |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
AT-FIBER-MONITORING-MIB AT-SMI-MIB AT-SYSINFO-MIB IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| atFiberMonNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.207.8.4.4.3.27.0 | |||
| atFiberMonTrapVariable OBJECT-IDENTITY | 1.3.6.1.4.1.207.8.4.4.3.27.1 | |||
| atFiberMonReading OBJECT-TYPE The current received optical power reading for the port specified in the trap (x0.0001mW) | 1.3.6.1.4.1.207.8.4.4.3.27.1.1 | Integer32 (0..65535) | accessible-for-notify | current |
| atFiberMonConfigTable OBJECT-TYPE It contains the objects used to configure the operation of fiber monitoring. | 1.3.6.1.4.1.207.8.4.4.3.27.2 | not-accessible | current | |
| atFiberMonConfigEntry OBJECT-TYPE Entry for the table. It contains the configurables of fiber monitering for an interface. | 1.3.6.1.4.1.207.8.4.4.3.27.2.1 | not-accessible | current | |
| atFiberMonIfname OBJECT-TYPE The name of the interface where the pluggable is in. | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.1 | OCTET STRING (SIZE(1..16)) | read-write | current |
| atFiberMonEnable OBJECT-TYPE Enable or disable fiber monitoring. | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.2 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| atFiberMonInterval OBJECT-TYPE Fiber monitoring polling interval in seconds. | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.3 | Integer32 (2..60) | read-write | current |
| atFiberMonSensitivity OBJECT-TYPE The sensitivity for fiber monitoring. Acceptable mode strings and value ranges are as below: low - 2dB medium - 1dB high - 0.5dB highest - 0.0025mW fixed <25 - 65535> - units of 0.0001mW relative <0.00 - 10.00> - units of dB For example, if you want to set the sensitivity to medium level, then you enter word medium Or if you want to set it to a fixed value, then you enter string fixed 1000 Or if you want to set to a relative value, then you enter string relative 1.20 | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.4 | OCTET STRING | read-write | current |
| atFiberMonBaseline OBJECT-TYPE The baseline value for firber mornitoring. Acceptable mode string and value ranges are as below: average <12-150> - number of readings used to calculate moving average. fixed <1-65535> - fixed baseline value in units of 0.0001mW. For example, if you want to use a moving average of 12 readings as the baseline, you enter average 12 Or if you want to use a fixed value, though it is not recommended, you enter fixed 500 | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.5 | OCTET STRING | read-write | current |
| atFiberMonAlarmAction OBJECT-TYPE Actions to take when an alarm occurs. Acceptable values are: 1. Log a message only. 2. Send snmp trap and log. 3. Shut down the interface and log. 4. Send trap, shutdown and log. | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.6 | INTEGER {logOnly(1), sendTrap(2), shutdown(3), sendtrapAndShutdown(4)} | read-write | current |
| atFiberMonStateTable OBJECT-TYPE This table contains the information of fiber monitoring state for SFPs. | 1.3.6.1.4.1.207.8.4.4.3.27.3 | not-accessible | current | |
| atFiberMonStateEntry OBJECT-TYPE Entry for fiber monitoring state table. It contains state values for a fiber channel. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1 | not-accessible | current | |
| atFiberMonIfindex OBJECT-TYPE The index of the interface where the pluggable is in. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.1 | Integer32 (1..2147483647) | read-only | current |
| atFiberMonChannel OBJECT-TYPE The channel number of the pluggable. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.2 | INTEGER (1..16) | read-only | current |
| atFiberMonlIfDescription OBJECT-TYPE Interface description. Normally it would be the name of the interface. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.3 | DisplayString | read-only | current |
| atFiberMonActualBaseline OBJECT-TYPE The calculated baseline value for the link, in units of 0.0001mW. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.4 | Integer32 (0..65535) | read-only | current |
| atFiberMonThreshold OBJECT-TYPE Threshold value for alarm to occur, in units of 0.0001mW. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.5 | Integer32 (0..65535) | read-only | current |
| atFiberMonReadingHistory OBJECT-TYPE The reading history. It is a string containing last 12 readings. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.6 | DisplayString | read-only | current |
| atFiberMonMinReading OBJECT-TYPE The minimum reading of rx power, in units of 0.0001mW. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.7 | Integer32 (0..65535) | read-only | current |
| atFiberMonMaxReading OBJECT-TYPE The maximum reading of rx power, in units of 0.0001mW. | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.8 | Integer32 (0..65535) | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| atFiberMonAlarmSetNotify NOTIFICATION-TYPE A notification generated when the monitored received optical power of an SFP goes outside its alarm threshold. | 1.3.6.1.4.1.207.8.4.4.3.27.0.1 | current |
| atFiberMonAlarmClearedNotify NOTIFICATION-TYPE A notification generated when the monitored received optical power of an SFP returns to an acceptable value. This can occur because the power has returned to its previous level or the comparison baseline has adjusted to the new level. | 1.3.6.1.4.1.207.8.4.4.3.27.0.2 | current |