MIBs Depot

ASYNCOS-MAIL-MIB

Registered at
1.3.6.1.4.1.15497.1.1.1
1.3.6.1.4.1.15497.1.1.2
Last updated
2011-03-07 00:00
Organization
IronPort Systems
Revisions
2011-03-07 00:00, 2010-07-01 00:00, 2009-04-07 00:00, 2009-01-15 00:00, 2005-03-07 00:00, 2005-01-09 00:00
Namespace
ironport
Source file
ASYNCOS-MAIL-MIB
Digest
sha256:6021d8fe2fae13a305f36445cd9d5bb2bb6d352904a06b2d2dbc7fae1b046f9c

Description

MIB for Cisco IronPort Mail Gateway/Email Security Appliances

Contact

Cisco IronPort Email and Web Security Customer Service Postal: 950 Elm Avenue San Bruno, CA 94066 USA Tel: +1 (650) 989-6533 E-mail: customercare@ironport.com

Imports

FromSymbols
IRONPORT-SMIasyncOSMail
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ASYNCOS-MAIL-MIB
IRONPORT-SMI
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
perCentMemoryUtilization
OBJECT-TYPE
This object provides a general idea of how much memory is being consumed by the appliance software.
1.3.6.1.4.1.15497.1.1.1.1Integer32 (0..100)read-onlycurrent
perCentCPUUtilization
OBJECT-TYPE
This object provides a general idea of how busy the CPU is according to the appliance software, within the last 5 seconds of utilization. This measurement may or may not reflect the overall CPU utilization of the appliance, and may or may not be a per-process or a per-thread CPU utilization value.
1.3.6.1.4.1.15497.1.1.1.2Integer32 (0..100)read-onlycurrent
perCentDiskIOUtilization
OBJECT-TYPE
This object provides a general idea of how much disk I/O has been generated within the last 5-15 seconds.
1.3.6.1.4.1.15497.1.1.1.3Integer32 (0..100)read-onlycurrent
perCentQueueUtilization
OBJECT-TYPE
Percent of total queue capacity used.
1.3.6.1.4.1.15497.1.1.1.4Integer32 (0..100)read-onlycurrent
queueAvailabilityStatus
OBJECT-TYPE
Queue space status: enough space, queue near full or queue full.
1.3.6.1.4.1.15497.1.1.1.5INTEGER {queueSpaceAvailable(1), queueSpaceShortage(2), queueFull(3)}read-onlycurrent
resourceConservationReason
OBJECT-TYPE
Reason system is in Resource Conservation Mode.
1.3.6.1.4.1.15497.1.1.1.6INTEGER {noResourceConservation(1), memoryShortage(2), queueSpaceShortage(3), queueFull(4)}read-onlycurrent
memoryAvailabilityStatus
OBJECT-TYPE
Mail Transfer process's memory availability status.
1.3.6.1.4.1.15497.1.1.1.7INTEGER {memoryAvailable(1), memoryShortage(2), memoryFull(3)}read-onlycurrent
powerSupplyTable
OBJECT-TYPE
A table of one or power supply entries.
1.3.6.1.4.1.15497.1.1.1.8not-accessiblecurrent
powerSupplyEntry
OBJECT-TYPE
Entry containing the status of a power supply and the corresponding power supply configuration redundancy state.
1.3.6.1.4.1.15497.1.1.1.8.1not-accessiblecurrent
powerSupplyIndex
OBJECT-TYPE
Unique index for a power supply source. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.8.1.1Integer32 (1..8)read-onlycurrent
powerSupplyStatus
OBJECT-TYPE
Represents the status of a power supply. powerSupplyNotInstalled - The power supply is not detected by the chassis as being physically present. powerSupplyHealthy - The power supply is physically present and is actively servicing the appliance with power. powerSupplyNoAC - The power supply is physically present but is not actively servicing the appliance with power. powerSupplyFaulty - The power supply is failed per the vendor defined operating specifications for the power supply.
1.3.6.1.4.1.15497.1.1.1.8.1.2INTEGER {powerSupplyNotInstalled(1), powerSupplyHealthy(2), powerSupplyNoAC(3), powerSupplyFaulty(4)}read-onlycurrent
powerSupplyRedundancy
OBJECT-TYPE
Represents the status of a collection of one or more power supplies. powerSupplyRedundancyOK - All power supplies are in a powerSupplyHealthy state. powerSupplyRedundancyLost - One or more power supplies are in a powerSupplyNotInstalled, powerSupplyNoAC, or powerSupplyFaulty state.
1.3.6.1.4.1.15497.1.1.1.8.1.3INTEGER {powerSupplyRedundancyOK(1), powerSupplyRedundancyLost(2)}read-onlycurrent
powerSupplyName
OBJECT-TYPE
A textual name for a power supply.
1.3.6.1.4.1.15497.1.1.1.8.1.4DisplayStringread-onlycurrent
temperatureTable
OBJECT-TYPE
A table of chassis temperature sensor states.
1.3.6.1.4.1.15497.1.1.1.9not-accessiblecurrent
temperatureEntry
OBJECT-TYPE
An entry in the temperature sensor table representing the status of the corresponding sensor in or on the appliance.
1.3.6.1.4.1.15497.1.1.1.9.1not-accessiblecurrent
temperatureIndex
OBJECT-TYPE
Unique index for the temperature sensor being instrumented. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.9.1.1Integer32 (1..64)not-accessiblecurrent
degreesCelsius
OBJECT-TYPE
Temperature reading for the sensor being instrumented in Centrigrade units. This is correct according to the relative accuracy of the sensor being instrumented.
1.3.6.1.4.1.15497.1.1.1.9.1.2Integer32read-onlycurrent
temperatureName
OBJECT-TYPE
Textual description for sensor being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
1.3.6.1.4.1.15497.1.1.1.9.1.3DisplayStringread-onlycurrent
fanTable
OBJECT-TYPE
A table of chassis fan entries.
1.3.6.1.4.1.15497.1.1.1.10not-accessiblecurrent
fanEntry
OBJECT-TYPE
An entry in the chassis fan table with the speed of a fan in the chassis, as well as the name of the corresponding fan.
1.3.6.1.4.1.15497.1.1.1.10.1not-accessiblecurrent
fanIndex
OBJECT-TYPE
Unique index of the chassis fan being instrumented. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.10.1.1Integer32 (1..64)not-accessiblecurrent
fanRPMs
OBJECT-TYPE
Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed.
1.3.6.1.4.1.15497.1.1.1.10.1.2Gauge32read-onlycurrent
fanName
OBJECT-TYPE
A textual name of the chassis fan being instrumented.
1.3.6.1.4.1.15497.1.1.1.10.1.3DisplayStringread-onlycurrent
workQueueMessages
OBJECT-TYPE
Number of messages in the work queue.
1.3.6.1.4.1.15497.1.1.1.11Gauge32read-onlycurrent
keyExpirationTable
OBJECT-TYPE
A table of Feature Key expiration entries.
1.3.6.1.4.1.15497.1.1.1.12not-accessiblecurrent
keyExpirationEntry
OBJECT-TYPE
Entry containing a Feature Key, its expiration status, and whether or not the Feature Key is perpetual.
1.3.6.1.4.1.15497.1.1.1.12.1not-accessiblecurrent
keyExpirationIndex
OBJECT-TYPE
Unique index for a Feature Key applicable to the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.12.1.1Integer32 (1..1024)read-onlycurrent
keyDescription
OBJECT-TYPE
Textual description for a Feature Key applicable to the appliance.
1.3.6.1.4.1.15497.1.1.1.12.1.2DisplayStringread-onlycurrent
keyIsPerpetual
OBJECT-TYPE
Boolean value represented by True if Feature Key is perpetual, or False if the Feature Key is normal or expired.
1.3.6.1.4.1.15497.1.1.1.12.1.3TruthValueread-onlycurrent
keySecondsUntilExpire
OBJECT-TYPE
Seconds until the valid Feature Key expires. Only applies to non-perpetual Feature Keys, and is 0 when the Feature Key has expired.
1.3.6.1.4.1.15497.1.1.1.12.1.4Gauge32read-onlycurrent
updateTable
OBJECT-TYPE
A table of one or more update entries.
1.3.6.1.4.1.15497.1.1.1.13not-accessiblecurrent
updateEntry
OBJECT-TYPE
Entry containing a name and number of successful and failed updates for a service, including but not limited to: spam or virus definitions and timezone updates.
1.3.6.1.4.1.15497.1.1.1.13.1not-accessiblecurrent
updateIndex
OBJECT-TYPE
Unique index for an update service. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.13.1.1Integer32 (1..1024)read-onlycurrent
updateServiceName
OBJECT-TYPE
A textual name for an update entry.
1.3.6.1.4.1.15497.1.1.1.13.1.2DisplayStringread-onlycurrent
updates
OBJECT-TYPE
The number of successful attempts that have occurred when updating a service.
1.3.6.1.4.1.15497.1.1.1.13.1.3Counter32read-onlycurrent
updateFailures
OBJECT-TYPE
The number of failed attempts that have occurred when updating a service.
1.3.6.1.4.1.15497.1.1.1.13.1.4Counter32read-onlycurrent
oldestMessageAge
OBJECT-TYPE
The number of seconds the oldest message has been in queue
1.3.6.1.4.1.15497.1.1.1.14Gauge32read-onlycurrent
outstandingDNSRequests
OBJECT-TYPE
Number of DNS requests that have been sent but for which no reply has been received.
1.3.6.1.4.1.15497.1.1.1.15Gauge32read-onlycurrent
pendingDNSRequests
OBJECT-TYPE
Number of DNS requests waiting to be sent.
1.3.6.1.4.1.15497.1.1.1.16Gauge32read-onlycurrent
raidEvents
OBJECT-TYPE
The total number of RAID events that have occurred since the last appliance power on event.
1.3.6.1.4.1.15497.1.1.1.17Counter32read-onlycurrent
raidTable
OBJECT-TYPE
Unique index for a drive being instrumented in the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.18not-accessiblecurrent
raidEntry
OBJECT-TYPE
An entry in the RAID table representing the status of a drive attached to a RAID controller in the appliance.
1.3.6.1.4.1.15497.1.1.1.18.1not-accessiblecurrent
raidIndex
OBJECT-TYPE
Unique index for a drive attached to a RAID controller in the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.18.1.1Integer32 (1..1024)read-onlycurrent
raidStatus
OBJECT-TYPE
Represents the status of a a drive attached to a RAID controller in the appliance. driveHealthy - The corresponding drive is connected to the RAID controller and functioning as a healthy member in the RAID volume. driveFailure - The drive is either disconnected from the RAID controller, or has failed to operate within thresholds defined in vendor specifications for the drive and the controller. driveRebuild - The corresponding drive is connected to the RAID controller. It is being rebuilt according to the RAID controller specific rebuild algorithm for the current operating mode of the RAID volume.
1.3.6.1.4.1.15497.1.1.1.18.1.2INTEGER {driveHealthy(1), driveFailure(2), driveRebuild(3)}read-onlycurrent
raidID
OBJECT-TYPE
A textual name for a drive attached to a RAID controller in the appliance.
1.3.6.1.4.1.15497.1.1.1.18.1.3DisplayStringread-onlycurrent
raidLastError
OBJECT-TYPE
The textual description of the last error message reported by the RAID controller or corresponding driver if one has occurred. This is 'No Error' if the corresponding drive's state is driveHealthy, or a controller or driver defined specific textual description if the drive's state is not driveHealthy.
1.3.6.1.4.1.15497.1.1.1.18.1.4DisplayStringread-onlycurrent
openFilesOrSockets
OBJECT-TYPE
This object notes how many files or sockets are open on the appliance. In normal operating conditions, the measurement is taken at least once every 5-15 seconds.
1.3.6.1.4.1.15497.1.1.1.19Gauge32read-onlycurrent
mailTransferThreads
OBJECT-TYPE
Number of threads that perform some task related to transferring mail.
1.3.6.1.4.1.15497.1.1.1.20Gauge32read-onlycurrent
connectionURL
OBJECT-TYPE
The URL which will be used to test HTTP URL connectivity.
1.3.6.1.4.1.15497.1.1.1.21DisplayStringaccessible-for-notifycurrent
hsmErrorReason
OBJECT-TYPE
A textual reason describing the last HSM authentication error.
1.3.6.1.4.1.15497.1.1.1.22DisplayStringread-onlycurrent
asyncOSMailNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.15497.1.1.2

Notifications

NameOIDStatus
resourceConservationMode
NOTIFICATION-TYPE
Memory or queue utilization caused system to enter resource conservation mode.
1.3.6.1.4.1.15497.1.1.2.1current
powerSupplyStatusChange
NOTIFICATION-TYPE
A powerSupplyStatusChange notification is sent when power supply with powerSupplyName changes states, as per one of the states available in powerSupplyStatus. This notification contains the opaque type for powerSupplyName of the power supply which has changed state.
1.3.6.1.4.1.15497.1.1.2.2current
highTemperature
NOTIFICATION-TYPE
A highTemperature notification is sent when the temperature of an instrumented sensor in the chassis has exceeded vendor defined specifications. This notification contains the opaque type for the temperatureName of the sensor which has failed.
1.3.6.1.4.1.15497.1.1.2.3current
fanFailure
NOTIFICATION-TYPE
A fanFailure notification is sent when the speed of the fan is not operating per the vendor defined specifications, as discussed in fanRPMs. This notification contains the opaque type for the fanName of the fan which has failed.
1.3.6.1.4.1.15497.1.1.2.4current
keyExpiration
NOTIFICATION-TYPE
A keyExpiration notification is sent when the corresponding Feature Key is pending expiration or has expired. This notification contains the opaque type for the keyDescription of the Feature Key that is pending expiration or has expired.
1.3.6.1.4.1.15497.1.1.2.5current
updateFailure
NOTIFICATION-TYPE
An updateFailure notification is sent when a service fails to update properly. This notification contains the opaque type for the updateServiceName of the update service that has failed.
1.3.6.1.4.1.15497.1.1.2.6current
raidStatusChange
NOTIFICATION-TYPE
A raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the opaque type for raidID of the drive which has changed state.
1.3.6.1.4.1.15497.1.1.2.7current
connectivityFailure
NOTIFICATION-TYPE
A connectivityFailure notification is sent when the URL denoted by configured connectionURL is unreachable, or the request returned an HTTP code was not between 200, inclusive, and 300, exclusive. The connectionURL configured is returned when the notification is triggered.
1.3.6.1.4.1.15497.1.1.2.8current
memoryUtilizationExceeded
NOTIFICATION-TYPE
A memoryUtilizationExceeded notification is sent when the value in perCentMemoryUtilization has exceeded the configured memory usage threshold. The percentage that exceeded the threshold in perCentMemoryUtilization is returned via the notification.
1.3.6.1.4.1.15497.1.1.2.9current
cpuUtilizationExceeded
NOTIFICATION-TYPE
A cpuUtilizationExceeded notification is sent when the value in perCentCPUUtilization has exceeded the configured CPU usage threshold. The percentage that exceeded the threshold in perCentCPUUtilization is returned via the notification.
1.3.6.1.4.1.15497.1.1.2.10current
hsmInitializationFailure
NOTIFICATION-TYPE
A hsmInitializationFailure notification is sent when the Hardware Security Module card cannot be initialized. The initialization error in hsmErrorReason is returned via the notification.
1.3.6.1.4.1.15497.1.1.2.11current
hsmResetLoginFailure
NOTIFICATION-TYPE
A hsmResetLoginFailure notification is sent when the Hardware Security Module card is reset due to multiple Crypto Officer login failures. The reset login error in hsmErrorReason is returned via the notification.
1.3.6.1.4.1.15497.1.1.2.12current