MIBs Depot

ASANTE-AH1012-MIB

Registered at
1.3.6.1.4.1.298
Namespace
asante
Source file
ASANTE-AH1012-MIB
Digest
sha256:dfc9d10a6a165f75e24abcc908ba0a6d0a69dac4ff31a824f821cd3b055f18f0

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso, private
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ASANTE-AH1012-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Under this module's arcs

Where the registration tree carries on below this module.

ArcNameModule
1.3.6.1.4.1.298.1products
1.3.6.1.4.1.298.2productId

Textual conventions

NameOIDSyntaxAccessStatus
DisplayString
type
PhysAddress
type

Objects

NameOIDSyntaxAccessStatus
asante
OBJECT-IDENTITY
1.3.6.1.4.1.298
products
OBJECT-IDENTITY
1.3.6.1.4.1.298.1
snmpAgent
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1
agentSw
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1.1
agentRunTimeImageMajorVer
OBJECT-TYPE
The major software version number of the agent run time image.
1.3.6.1.4.1.298.1.1.1.1INTEGERread-onlymandatory
agentRunTimeImageMinorVer
OBJECT-TYPE
The minor software version number of the agent run time image.
1.3.6.1.4.1.298.1.1.1.2INTEGERread-onlymandatory
agentImageLoadMode
OBJECT-TYPE
Tells hub whether the software image is to be loaded from the FLASH EPROM or from over the network.
1.3.6.1.4.1.298.1.1.1.3INTEGER {other(1), localBoot(2), netBoot(3)}read-writemandatory
agentRemoteBootInfo
OBJECT-TYPE
The method for getting boot parameter information.
1.3.6.1.4.1.298.1.1.1.4INTEGER {other(1), eepromBootInfo(2)}read-onlymandatory
agentRemoteBootProtocol
OBJECT-TYPE
The netboot protocol that used to load the agent software.
1.3.6.1.4.1.298.1.1.1.5INTEGER {other(1), bootp-tftp(2), tftp-only(3)}read-writemandatory
agentRemoteBootFile
OBJECT-TYPE
The boot file name that is sent to the boot file server by agent boot code during boot time.
1.3.6.1.4.1.298.1.1.1.6OCTET STRING (SIZE(0..64))read-writemandatory
agentOutBandDialString
OBJECT-TYPE
This is the initialization string used by the Network Management station to establish the out-of-band connection for modem only.
1.3.6.1.4.1.298.1.1.1.7OCTET STRING (SIZE(0..64))read-writemandatory
agentOutBandBaudRate
OBJECT-TYPE
The baud rate setting for the out-of-band port.
1.3.6.1.4.1.298.1.1.1.8INTEGER {other(1), b1200(2), b2400(3), b4800(4), b9600(5)}read-writemandatory
agentReset
OBJECT-TYPE
The object to allow software to perform 'push_button' system reset.
1.3.6.1.4.1.298.1.1.1.9INTEGER {other(1), reset(2), not-reset(3)}read-writemandatory
agentFw
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1.2
agentFwMajorVer
OBJECT-TYPE
The major firmware version number of the agent prom code.
1.3.6.1.4.1.298.1.1.2.1INTEGERread-onlymandatory
agentFwMinorVer
OBJECT-TYPE
The minor firmware version number of the agent prom code.
1.3.6.1.4.1.298.1.1.2.2INTEGERread-onlymandatory
agentHw
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1.3
agentHwReVer
OBJECT-TYPE
The hardware reversion number of the network management module.
1.3.6.1.4.1.298.1.1.3.1INTEGERread-onlymandatory
agentHwVer
OBJECT-TYPE
The hardware model number of the network management module
1.3.6.1.4.1.298.1.1.3.2INTEGERread-onlymandatory
agentNetProtoStkCapMap
OBJECT-TYPE
This octet string represents the current protocol stack configuration supported by the agent, encoded as a bit string. Each protocol stack is represented by a single bit. When the value of a bit = 1, it indicates that the protocol stack on the agent represented by that bit is supported; when zero, the protocol stack is not supported. The number of octets in the string is always integer multiple of the octet. The first protocol stack will encode in the least significant bit of the first octet. Current, only IP Stack(bit 0) and IPX Stack(bit 1) were defined, all other bits should be zero.
1.3.6.1.4.1.298.1.1.4OCTET STRING (SIZE(1..4))read-onlymandatory
agentNetProtocol
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1.5
ipagentProtocol
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.1.5.1
ipagentIpAddr
OBJECT-TYPE
The ipagent's administrative IP address. The current operational IP address can be obtained from the ipAdEntAddr in the ipAddrTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM.
1.3.6.1.4.1.298.1.1.5.1.1IpAddressread-writemandatory
ipagentIpNetMask
OBJECT-TYPE
The ipagent's administrative IP subnet mask. The current operational IP subnet mask can be obtained from the ipAdEntMask in the ipAddrTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM.
1.3.6.1.4.1.298.1.1.5.1.2IpAddressread-writemandatory
ipagentDefaultGateway
OBJECT-TYPE
The ipagent's administrative default gateway IP address. The current operational IP default gateway IP address can be obtained from the ipRouteDest in the ipRouteTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM.
1.3.6.1.4.1.298.1.1.5.1.3IpAddressread-writemandatory
ipagentBootServerAddr
OBJECT-TYPE
The IP address of the boot server that was used for booting this ipagent. This parameter will always be updated in the EEPROM.
1.3.6.1.4.1.298.1.1.5.1.4IpAddressread-writemandatory
ipagentUnAuthIP
OBJECT-TYPE
The IP address of the last station that tried to access this ipagent with an invalid community string.
1.3.6.1.4.1.298.1.1.5.1.5IpAddressread-onlymandatory
ipagentUnAuthComm
OBJECT-TYPE
The community string of the last station that tried to access this ipagent with an invalid community string.
1.3.6.1.4.1.298.1.1.5.1.6OCTET STRINGread-onlymandatory
ipagentTrapRcvrTable
OBJECT-TYPE
Table consisting of the list of Network Management Stations that are to receive traps generated by this agent.
1.3.6.1.4.1.298.1.1.5.2not-accessiblemandatory
ipagentTrapRcvrEntry
OBJECT-TYPE
Destination IP address and community string for a particular trap server.
1.3.6.1.4.1.298.1.1.5.2.1not-accessiblemandatory
ipagentTrapRcvrIpAddr
OBJECT-TYPE
IP address for trap server receiving trap.
1.3.6.1.4.1.298.1.1.5.2.1.1IpAddressread-onlymandatory
ipagentTrapRcvrStatus
OBJECT-TYPE
Validation of individual trap receiver. If value of this object is set to invalid(3), then that particular entry is deemed invalid, meaning that the address for that entry is no longer valid because the entry has been removed from the table.
1.3.6.1.4.1.298.1.1.5.2.1.2INTEGER {other(1), valid(2), invalid(3)}read-writemandatory
ipagentTrapRcvrComm
OBJECT-TYPE
Community string for traps sent to this trap receiver.
1.3.6.1.4.1.298.1.1.5.2.1.3OCTET STRINGread-writemandatory
adaptCard
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.2
concentrator
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3
concChassis
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.1
concBasicGrp
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.1.1
concChassisType
OBJECT-TYPE
The concentrator's chassis type.
1.3.6.1.4.1.298.1.3.1.1.1INTEGER {other(1), aH1012(2)}read-onlymandatory
concChassisBkplType
OBJECT-TYPE
The concentrator's chassis backplane type.
1.3.6.1.4.1.298.1.3.1.1.2INTEGER {other(1), no-backplane(2)}read-onlymandatory
concChassisBkplRev
OBJECT-TYPE
The concentrator's chassis backplane revision number.
1.3.6.1.4.1.298.1.3.1.1.3INTEGERread-onlymandatory
concChassisPsTable
OBJECT-TYPE
This table contains concentrator's power supply information.
1.3.6.1.4.1.298.1.3.1.1.4not-accessiblemandatory
concChassisPsEntry
OBJECT-TYPE
The entry in the table containing the information about a single power supply.
1.3.6.1.4.1.298.1.3.1.1.4.1not-accessiblemandatory
concChassisPsIndex
OBJECT-TYPE
The value of this object identifies the power supply table for which this entry contains power supply type and status.
1.3.6.1.4.1.298.1.3.1.1.4.1.1INTEGERread-onlymandatory
concChassisPsModuleType
OBJECT-TYPE
The value of this object identifies the power supply module type.
1.3.6.1.4.1.298.1.3.1.1.4.1.2INTEGER {other(1)}read-onlymandatory
concChassisPsStatus
OBJECT-TYPE
The value of this object identifies the power supply module status.
1.3.6.1.4.1.298.1.3.1.1.4.1.3INTEGER {other(1), good(2), bad(3)}read-onlymandatory
concChassisFanStatus
OBJECT-TYPE
The value of this object identifies the fan status.
1.3.6.1.4.1.298.1.3.1.1.5INTEGER {other(1), no-fan(2), good(3), bad(4)}read-onlymandatory
concChassisGroupCapacity
OBJECT-TYPE
The number of groups that can be contained within the concentrator.
1.3.6.1.4.1.298.1.3.1.1.6INTEGERread-onlymandatory
concChassisGroupMap
OBJECT-TYPE
This octet string represents the current configuration of groups, encoded as a bit string, each group is represented by a single bit.
1.3.6.1.4.1.298.1.3.1.1.7OCTET STRINGread-onlymandatory
concChassisGrpTable
OBJECT-TYPE
A table that contains information about the group/slot in this chassis.
1.3.6.1.4.1.298.1.3.1.1.8not-accessiblemandatory
concChassisGrpEntry
OBJECT-TYPE
A list of information for each slot in this chassis.
1.3.6.1.4.1.298.1.3.1.1.8.1not-accessiblemandatory
concChassisGrpIndex
OBJECT-TYPE
The value of this object identifies the chassis group table for which this entry contains group related information.
1.3.6.1.4.1.298.1.3.1.1.8.1.1INTEGERread-onlymandatory
concChassisGrpNumberPort
OBJECT-TYPE
The number of port is available for up/down link within this group.
1.3.6.1.4.1.298.1.3.1.1.8.1.2INTEGERread-onlymandatory
concChassisGrpType
OBJECT-TYPE
The value represents the function of this group.
1.3.6.1.4.1.298.1.3.1.1.8.1.3INTEGERread-onlymandatory
concChassisGrpDescr
OBJECT-TYPE
A description of this group device.
1.3.6.1.4.1.298.1.3.1.1.8.1.4DisplayStringread-onlymandatory
concChassisGrpHwRev
OBJECT-TYPE
The hardware revision number of this particular group.
1.3.6.1.4.1.298.1.3.1.1.8.1.5INTEGERread-onlymandatory
concConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.2
eSmartHubConfig
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.2.1
eSmartHubId
OBJECT-TYPE
Hub MAC address (octet string) found from prom chip in hub.
1.3.6.1.4.1.298.1.3.2.1.1PhysAddressread-onlymandatory
eSmartHubAssignedId
OBJECT-TYPE
Assigned hub ID for Out-of-Band.
1.3.6.1.4.1.298.1.3.2.1.2INTEGERread-onlymandatory
eSmartHubTerSwitch
OBJECT-TYPE
Status of position of PC/terminal switch located on rear panel of hub. Switches between serial and parallel communications for modem/PC or terminal connection to RS-232 Port. Up (off) for PC, down (on) for terminal. If position of switch is changed, there will be no change in this status until hub is reset.
1.3.6.1.4.1.298.1.3.2.1.3INTEGER {other(1), terminal(2), pc-modem(3)}read-onlymandatory
eSmartHubHwLoadPatStatus
OBJECT-TYPE
Which logic configuration pattern is loaded into the Programmable Logic Device PLD.
1.3.6.1.4.1.298.1.3.2.1.4INTEGERread-writemandatory
eSmartHubHwLoadPatCapacity
OBJECT-TYPE
What kind of function the PLD can perform.
1.3.6.1.4.1.298.1.3.2.1.5OCTET STRINGread-onlymandatory
eSmartHubNodeAgeTimer
OBJECT-TYPE
How long to keep node entry in node summary table, measured in sec. The maximum is 11 hours.
1.3.6.1.4.1.298.1.3.2.1.6INTEGERread-writemandatory
eSmartHub3in1LnConStatus
OBJECT-TYPE
Status of 3In1 Uplink which is located on rear panel of hub. Describes the physical link type or types currently connected.
1.3.6.1.4.1.298.1.3.2.1.7INTEGER {other(1), uTP(2), aUI(3), uTP-and-AUI(4)}read-onlymandatory
eSmartHub3in1StateCtrl
OBJECT-TYPE
Whether using Auto-sense or manually selected a particular media type for the uplink connection. If using Auto-sense it first tries AUI. If AUI is not present then 10T. If neither AUI nor 10T is present, then it defaults to BNC.
1.3.6.1.4.1.298.1.3.2.1.8INTEGER {other(1), uTP(2), bNC(3), aUI(4), auto(5)}read-writemandatory
concStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.3
eStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.3.1
eGlobalStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.3.1.1
eGlobalHubReadableFrames
OBJECT-TYPE
Global counter of good or readable frames for this hub. Frame is between 64 and 1518 bytes in length and has SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.1.1Counterread-onlymandatory
eGlobalHubMcastFrames
OBJECT-TYPE
Global counter of number of multicast frames for this hub. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.1.2Counterread-onlymandatory
eGlobalHubBcastFrames
OBJECT-TYPE
Global counter of number of broadcast frames for his hub. All 1s in network destination address. Multicast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.1.3Counterread-onlymandatory
eGlobalHubFrameTooLongs
OBJECT-TYPE
Global counter, for this hub, of data frames longer than 1518 bytes, with a SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.1.4Counterread-onlymandatory
eGlobalHubRunts
OBJECT-TYPE
Global counter, for this hub, of data frames with size less than 64 bytes, with no CRC or alignment errors.
1.3.6.1.4.1.298.1.3.3.1.1.5Counterread-onlymandatory
eGlobalHubAlignmentErrors
OBJECT-TYPE
Global counter, for this hub, of frames which are not integer multiples of 1 byte.
1.3.6.1.4.1.298.1.3.3.1.1.6Counterread-onlymandatory
eGlobalHubFragmentErrors
OBJECT-TYPE
Global counter, for this hub, of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error).
1.3.6.1.4.1.298.1.3.3.1.1.7Counterread-onlymandatory
eGlobalHubFCSErrors
OBJECT-TYPE
Global counter, for this hub, of frames that failed Cyclic Redundancy Check (CRC).
1.3.6.1.4.1.298.1.3.3.1.1.8Counterread-onlymandatory
eGlobalHubIFGErrors
OBJECT-TYPE
Global counter, for this hub, of occurrences of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds.
1.3.6.1.4.1.298.1.3.3.1.1.9Counterread-onlymandatory
eGlobalHubDataRateMismatchs
OBJECT-TYPE
Global counter, for this hub, of errors where incoming data rate is not with in the tolerance level of 10MHZ + or - 0.01%.
1.3.6.1.4.1.298.1.3.3.1.1.10Counterread-onlymandatory
eGlobalHubShortEvents
OBJECT-TYPE
Global counter, for this hub, of data burst where data is less than 10 bytes in length, with no SFD.
1.3.6.1.4.1.298.1.3.3.1.1.11Counterread-onlymandatory
eGlobalHubCollisions
OBJECT-TYPE
Global counter of collision flags, for this hub.
1.3.6.1.4.1.298.1.3.3.1.1.12Counterread-onlymandatory
eGlobalHubLateCollisions
OBJECT-TYPE
Global counter, for this hub, of collisions occurring after the 64 byte collision window.
1.3.6.1.4.1.298.1.3.3.1.1.13Counterread-onlymandatory
eGlobalHubMJLPs
OBJECT-TYPE
Global counter of MAU jabber lockup protection where hub repeater chip goes into lockup state.
1.3.6.1.4.1.298.1.3.3.1.1.14Counterread-onlymandatory
eGlobalHubAutoPartitions
OBJECT-TYPE
Global counter, for this hub, of all ports including 3in1 port being partitioned from network in response to 31 or more continuous collisions.
1.3.6.1.4.1.298.1.3.3.1.1.15Counterread-onlymandatory
eGlobalHubSFDMissings
OBJECT-TYPE
Global counter, for this hub, of a burst of data greater than or equal to 10 bytes in length with no SFD.
1.3.6.1.4.1.298.1.3.3.1.1.16Counterread-onlymandatory
eGlobalHubBadFrames
OBJECT-TYPE
Global counter, for this hub, of total errored frame including toolong, runts, misaligned, or bad FCS.
1.3.6.1.4.1.298.1.3.3.1.1.17Counterread-onlymandatory
eGrpStatisticsTable
OBJECT-TYPE
Table of statistical information for each group.
1.3.6.1.4.1.298.1.3.3.1.3not-accessiblemandatory
eGrpStatisticsEntry
OBJECT-TYPE
Entry for individual group in table.
1.3.6.1.4.1.298.1.3.3.1.3.1not-accessiblemandatory
eGrpStatIndex
OBJECT-TYPE
The value of this object identifies the group for which this entry contains group statistical information.
1.3.6.1.4.1.298.1.3.3.1.3.1.1INTEGERread-onlymandatory
eGrpStatReadableFrames
OBJECT-TYPE
Group counter of 'good' or readable frames. Frame is between 64 and 1518 bytes in length and has SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.3.1.2Counterread-onlymandatory
eGrpStatMcastFrames
OBJECT-TYPE
Group counter of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.3.1.3Counterread-onlymandatory
eGrpStatBcastFrames
OBJECT-TYPE
Group counter of number of broadcast frames. All 1s in network destination address. Multicast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.3.1.4Counterread-onlymandatory
eGrpStatFrameTooLongs
OBJECT-TYPE
Group counter for data frames longer than 1518 bytes, with a SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.3.1.5Counterread-onlymandatory
eGrpStatRunts
OBJECT-TYPE
Group counter for data frames with size less than 64 bytes, with no CRC or alignment errors.
1.3.6.1.4.1.298.1.3.3.1.3.1.6Counterread-onlymandatory
eGrpStatAlignmentErrors
OBJECT-TYPE
Group counter of frames which are not integer multiples of 1 byte .
1.3.6.1.4.1.298.1.3.3.1.3.1.7Counterread-onlymandatory
eGrpStatFragmentErrors
OBJECT-TYPE
Group counter of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error).
1.3.6.1.4.1.298.1.3.3.1.3.1.8Counterread-onlymandatory
eGrpStatFCSErrors
OBJECT-TYPE
Group counter frames that failed Cyclic Redundancy Check (CRC).
1.3.6.1.4.1.298.1.3.3.1.3.1.9Counterread-onlymandatory
eGrpStatIFGErrors
OBJECT-TYPE
Group counter of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds.
1.3.6.1.4.1.298.1.3.3.1.3.1.10Counterread-onlymandatory
eGrpStatDataRateMismatchs
OBJECT-TYPE
Group counter of errors where incoming data rate is not with in the tolerance level of 10 MHZ + or - 0.01%.
1.3.6.1.4.1.298.1.3.3.1.3.1.11Counterread-onlymandatory
eGrpStatShortEvents
OBJECT-TYPE
Group counter of data burst where data is less than 10 bytes in length, with no SFD.
1.3.6.1.4.1.298.1.3.3.1.3.1.12Counterread-onlymandatory
eGrpStatCollisions
OBJECT-TYPE
Group counter of collision flags.
1.3.6.1.4.1.298.1.3.3.1.3.1.13Counterread-onlymandatory
eGrpStatLateCollisions
OBJECT-TYPE
Group counter of collisions occurring after the 64 byte collision window.
1.3.6.1.4.1.298.1.3.3.1.3.1.14Counterread-onlymandatory
eGrpStatMJLPs
OBJECT-TYPE
Group counter of MAU jabber lockup protection where hub repeater chip goes into lockup state.
1.3.6.1.4.1.298.1.3.3.1.3.1.15Counterread-onlymandatory
eGrpStatAutoPartitions
OBJECT-TYPE
Group counter of ports in group autopartitioned in response to 31 or more continuous collisions.
1.3.6.1.4.1.298.1.3.3.1.3.1.16Counterread-onlymandatory
eGrpStatSFDMissings
OBJECT-TYPE
Group counter of a burst of data greater than or equal to 10 bytes in length with no SFD.
1.3.6.1.4.1.298.1.3.3.1.3.1.17Counterread-onlymandatory
eGrpStatBadFrames
OBJECT-TYPE
Group counter of total errored frames including toolong, runts, misaligned, or bad FCS.
1.3.6.1.4.1.298.1.3.3.1.3.1.18Counterread-onlymandatory
ePortStatisticsTable
OBJECT-TYPE
Table for port specific network statistics.
1.3.6.1.4.1.298.1.3.3.1.4not-accessiblemandatory
ePortStatisticsEntry
OBJECT-TYPE
Entry for individual port in table.
1.3.6.1.4.1.298.1.3.3.1.4.1not-accessiblemandatory
ePortGrpIndex
OBJECT-TYPE
The value of this object identifies the group for which this entry contains port statistical information.
1.3.6.1.4.1.298.1.3.3.1.4.1.1INTEGERread-onlymandatory
ePortIndex
OBJECT-TYPE
The value of this object identifies the port for which this entry contains port statistical information.
1.3.6.1.4.1.298.1.3.3.1.4.1.2INTEGERread-onlymandatory
ePortStatReadableFrames
OBJECT-TYPE
Port counter of good or readable frames. Frame is between 64 and 1518 bytes in length and has SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.4.1.3Counterread-onlymandatory
ePortStatMcastFrames
OBJECT-TYPE
Port counter of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.4.1.4Counterread-onlymandatory
ePortStatBcastFrames
OBJECT-TYPE
Port counter of number of broadcast frames. All 1s in network destination address. Multicast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.4.1.5Counterread-onlymandatory
ePortStatFrameTooLongs
OBJECT-TYPE
Port counter for data frames longer than 1518 bytes, with a SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.4.1.6Counterread-onlymandatory
ePortStatRunts
OBJECT-TYPE
Port counter for data frames with size less than 64 bytes, with no CRC or alignment errors.
1.3.6.1.4.1.298.1.3.3.1.4.1.7Counterread-onlymandatory
ePortStatAlignmentErrors
OBJECT-TYPE
Port counter of frames which are not integer multiples of 1 byte.
1.3.6.1.4.1.298.1.3.3.1.4.1.8Counterread-onlymandatory
ePortStatFragmentErrors
OBJECT-TYPE
Port counter of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error).
1.3.6.1.4.1.298.1.3.3.1.4.1.9Counterread-onlymandatory
ePortStatFCSErrors
OBJECT-TYPE
Port counter of frames that failed Cyclic Redundancy Check (CRC).
1.3.6.1.4.1.298.1.3.3.1.4.1.10Counterread-onlymandatory
ePortStatIFGErrors
OBJECT-TYPE
Port counter of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds.
1.3.6.1.4.1.298.1.3.3.1.4.1.11Counterread-onlymandatory
ePortStatDataRateMismatchs
OBJECT-TYPE
Port counter of errors where incoming data rate is not with in the tolerance level of 10 MHZ + or - 0.01%.
1.3.6.1.4.1.298.1.3.3.1.4.1.12Counterread-onlymandatory
ePortStatShortEvents
OBJECT-TYPE
Port counter of data burst where data is less than 10 bytes in length, with no SFD.
1.3.6.1.4.1.298.1.3.3.1.4.1.13Counterread-onlymandatory
ePortStatCollisions
OBJECT-TYPE
Port counter of collision flags.
1.3.6.1.4.1.298.1.3.3.1.4.1.14Counterread-onlymandatory
ePortStatLateCollisions
OBJECT-TYPE
Port counter of collisions occurring after the 64 byte collision window.
1.3.6.1.4.1.298.1.3.3.1.4.1.15Counterread-onlymandatory
ePortStatMJLPs
OBJECT-TYPE
Port counter of MAU jabber lockup protection where hub repeater chip goes into lockup state.
1.3.6.1.4.1.298.1.3.3.1.4.1.16Counterread-onlymandatory
ePortStatAutoPartitions
OBJECT-TYPE
Port counter of number of times port was autopartitioned in response to 31 or more continuous collisions.
1.3.6.1.4.1.298.1.3.3.1.4.1.17Counterread-onlymandatory
ePortStatSFDMissings
OBJECT-TYPE
Port counter of a burst of data greater than or equal to 10 bytes in length with no SFD.
1.3.6.1.4.1.298.1.3.3.1.4.1.18Counterread-onlymandatory
ePortStatBadFrames
OBJECT-TYPE
Port counter of total errored frames including toolong, runts, misaligned, or bad FCS.
1.3.6.1.4.1.298.1.3.3.1.4.1.19Counterread-onlymandatory
eTrafficMatrixTable
OBJECT-TYPE
Table to analyze the number of packets received through network traffic by the size of each packet.
1.3.6.1.4.1.298.1.3.3.1.5not-accessiblemandatory
eTrafficMatrixEntry
OBJECT-TYPE
Individual entry in matrix of packet lengths table.
1.3.6.1.4.1.298.1.3.3.1.5.1not-accessiblemandatory
eTrafficMatrixLength
OBJECT-TYPE
Starting length for each range in table.
1.3.6.1.4.1.298.1.3.3.1.5.1.1INTEGERread-onlymandatory
eTrafficMatrixRange
OBJECT-TYPE
Range of packet sizes to be scanned for in network traffic.
1.3.6.1.4.1.298.1.3.3.1.5.1.2INTEGER {other(1), from-1-to-63-bytes(2), from-64-to-127-bytes(3), from-128-to-255-bytes(4), from-256-to-511-bytes(5), from-512-to-767-bytes(6), from-768-to-1023-bytes(7), from-1024-to-1518-bytes(8), from-512-to-1023-bytes(9), from-65-to-511-bytes(10), exact-64-bytes(11), over-1518-bytes(12)}read-onlymandatory
eTrafficMatrixFramesCounts
OBJECT-TYPE
Counter for number of frames received for particular range specified by the MatrixRange.
1.3.6.1.4.1.298.1.3.3.1.5.1.3Counterread-onlymandatory
eSpecific
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.3.1.6
eSmartHubSpec
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.3.1.6.1
eColGraphBar
OBJECT-TYPE
Information on hardware LED collision graph bar.
1.3.6.1.4.1.298.1.3.3.1.6.1.1INTEGERread-onlymandatory
eUtilGraphBar
OBJECT-TYPE
Information on hardware LED for utilization graph bar.
1.3.6.1.4.1.298.1.3.3.1.6.1.2INTEGERread-onlymandatory
ePortRateTable
OBJECT-TYPE
Network statistics for individual ports measured in Rate/Second.
1.3.6.1.4.1.298.1.3.3.1.6.1.6not-accessibleoptional
ePortRateEntry
OBJECT-TYPE
Individual entry in port rate table.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1not-accessibleoptional
ePortRateGrpIndex
OBJECT-TYPE
The value of this object identifies the group for which this entry contains port statistical information.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.1INTEGERread-onlyoptional
ePortRatePortIndex
OBJECT-TYPE
This value identifies the port for which this entry contains port statistical information.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.2INTEGERread-onlyoptional
ePortRateReadableFrames
OBJECT-TYPE
Rate of occurrence of good or readable frames.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.3INTEGERread-onlyoptional
ePortRateMcastFrames
OBJECT-TYPE
Rate of occurrence of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.4INTEGERread-onlyoptional
ePortRateBcastFrames
OBJECT-TYPE
Rate of occurrence of number of broadcast frames. All 1s in network destination address. Multicast packets are not included.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.5INTEGERread-onlyoptional
ePortRateFrameTooLongs
OBJECT-TYPE
Rate of occurrence of data frames longer than 1518 bytes, with a SFD and good FCS.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.6INTEGERread-onlyoptional
ePortRateRunts
OBJECT-TYPE
Rate of occurrence of data frames with size less than 64 bytes, with no CRC or alignment errors.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.7INTEGERread-onlyoptional
ePortRateAlignmentErrors
OBJECT-TYPE
Rate of occurrence of frames which are not integer multiples of 1 byte.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.8INTEGERread-onlyoptional
ePortRateFragmentErrors
OBJECT-TYPE
Rate of occurrence of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error).
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.9INTEGERread-onlyoptional
ePortRateFCSErrors
OBJECT-TYPE
Rate of occurrence of frames that failed Cyclic Redundancy Check (CRC).
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.10INTEGERread-onlyoptional
ePortRateIFGErrors
OBJECT-TYPE
Rate of occurrence of interframe Gap Errors where time period between data frames is less than 5.5 micro seconds.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.11INTEGERread-onlyoptional
ePortRateDataRateMismatch
OBJECT-TYPE
Rate of occurrence of errors where incoming data rate is not with in the tolerance level of 10 MHz + or - 0.01%.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.12INTEGERread-onlyoptional
ePortRateShortEvents
OBJECT-TYPE
Rate of occurrence of data burst where data is less than 10 bytes in length, with no SFD.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.13INTEGERread-onlyoptional
ePortRateCollisions
OBJECT-TYPE
Rate of occurrence of collision flags.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.14INTEGERread-onlyoptional
ePortRateLateCollisions
OBJECT-TYPE
Rate of occurrence of collisions occurring after the 64 byte collision window.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.15INTEGERread-onlyoptional
ePortRateMJLPs
OBJECT-TYPE
Rate of occurrence of MAU jabber lockup protection where hub repeater chip goes into lockup state.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.16INTEGERread-onlyoptional
ePortRateAutoPartitions
OBJECT-TYPE
Rate of occurrence of times port was autopartitioned in response to 31 or more continuous collisions.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.17INTEGERread-onlyoptional
ePortRateSFDMissings
OBJECT-TYPE
Rate of occurrence of a burst of data greater than or equal to 10 bytes in length with no SFD.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.18INTEGERread-onlyoptional
ePortRateBadFrames
OBJECT-TYPE
Rate of occurrence of total errored frames including toolong, runts, misaligned, or bad FCS.
1.3.6.1.4.1.298.1.3.3.1.6.1.6.1.19INTEGERread-onlyoptional
concStateCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.4
eStateCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.4.1
ePortStateCtrlTable
OBJECT-TYPE
Table for port control parameters.
1.3.6.1.4.1.298.1.3.4.1.1not-accessiblemandatory
ePortStateCtrlEntry
OBJECT-TYPE
Individual entry of port control in table.
1.3.6.1.4.1.298.1.3.4.1.1.1not-accessiblemandatory
ePortStateGrpIndex
OBJECT-TYPE
The value of this object identifies the group for which this entry contains port control information.
1.3.6.1.4.1.298.1.3.4.1.1.1.1INTEGERread-onlymandatory
ePortStatePortIndex
OBJECT-TYPE
This value identifies the port for which this entry contains port control information.
1.3.6.1.4.1.298.1.3.4.1.1.1.2INTEGERread-onlymandatory
ePortStateType
OBJECT-TYPE
Type of cabling physically connected to port.
1.3.6.1.4.1.298.1.3.4.1.1.1.3INTEGER {other(1), bNC(2), aUI(3), rJ45(4), foil(5), three-in-one(6)}read-onlymandatory
ePortStateLinkStatus
OBJECT-TYPE
Link status for particular port. On=physical link if link test enabled. Off=no physical link exists or link test is disabled.
1.3.6.1.4.1.298.1.3.4.1.1.1.4INTEGER {others(1), linkon(2), linkoff(3)}read-onlymandatory
ePortStateLinkIntegTest
OBJECT-TYPE
Set can enable or disabled link integrity test. Get will say if link integrity test is enabled (2) or disabled (3).
1.3.6.1.4.1.298.1.3.4.1.1.1.5INTEGER {others(1), linkTestEnable(2), linkTestDisable(3)}read-writemandatory
ePortStateAutoPartStatus
OBJECT-TYPE
Whether port has been autopartitioned (2) or not autopartitioned (3).
1.3.6.1.4.1.298.1.3.4.1.1.1.6INTEGER {others(1), autopartitioned(2), notautopartitioned(3)}read-onlymandatory
ePortStateJabberStatus
OBJECT-TYPE
Jabber detection for port. If On(2), then jabber occurred on this port. Off(3), then no jabber occurred or jabber detection has been manually disabled.
1.3.6.1.4.1.298.1.3.4.1.1.1.7INTEGER {others(1), on(2), off(3)}read-onlymandatory
ePortStateJabberState
OBJECT-TYPE
Set can enable or disable jabber detection test. Get will say if jabber detection test is enabled (2) or disabled (3).
1.3.6.1.4.1.298.1.3.4.1.1.1.8INTEGER {others(1), enabled(2), disabled(3)}read-writemandatory
ePortStateAdminState
OBJECT-TYPE
Set will manually enable or disable any port. Get will say if port has been enabled (2) or disabled (3).
1.3.6.1.4.1.298.1.3.4.1.1.1.9INTEGER {others(1), enabled(2), disabled(3)}read-writemandatory
ePortStateRDTState
OBJECT-TYPE
Whether RecvThreshold has been enabled or disabled. Can use this to lower noise threshold (tolerance) so that longer twisted pair links can be used.
1.3.6.1.4.1.298.1.3.4.1.1.1.10INTEGER {others(1), unreduce(2), reduce(3)}read-writemandatory
ePortStatePolarityStatus
OBJECT-TYPE
Polarity is correct (2) or not for this port.
1.3.6.1.4.1.298.1.3.4.1.1.1.11INTEGER {others(1), normal(2), reversed(3)}read-onlymandatory
ePortStatePolarityState
OBJECT-TYPE
Autopolarity correction enabled or disabled. Allows hub to make electrical corrections automatically if cable does not reverse polarity within wire pairs. If do not want this correction to take place, autocorrection can be disabled.
1.3.6.1.4.1.298.1.3.4.1.1.1.12INTEGER {others(1), enabled(2), disabled(3)}read-writemandatory
concNodeMgt
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.5
nodeSummaryTable
OBJECT-TYPE
Node summary of all traffic through hub.
1.3.6.1.4.1.298.1.3.5.1not-accessiblemandatory
nodeSummaryEntry
OBJECT-TYPE
Individual entry in node summary table.
1.3.6.1.4.1.298.1.3.5.1.1not-accessiblemandatory
nodeSummaryGrpIndex
OBJECT-TYPE
Group Id for identifying the group where node activity is detected.
1.3.6.1.4.1.298.1.3.5.1.1.1INTEGERread-onlymandatory
nodeSummaryPortIndex
OBJECT-TYPE
Port Id for identifying the port where node activity is detected.
1.3.6.1.4.1.298.1.3.5.1.1.2INTEGERread-onlymandatory
nodeSummarySrcMacAddr
OBJECT-TYPE
The source MAC address of the node that is transmitting frames received by this port.
1.3.6.1.4.1.298.1.3.5.1.1.3PhysAddressread-onlymandatory
nodeSummaryDestMacAddr
OBJECT-TYPE
The destination MAC address of the node to which frames are being received by this port.
1.3.6.1.4.1.298.1.3.5.1.1.4PhysAddressread-onlymandatory
nodeSummaryEtherType
OBJECT-TYPE
The 2 bytes after the source (src) address in packet.
1.3.6.1.4.1.298.1.3.5.1.1.5INTEGERread-onlymandatory
nodeSummaryIpAddrPair
OBJECT-TYPE
Destination and source IP address if packet is an Ethernet IP packet. It the packet is not an Ethernet IP packet, then the information may not be accurate.
1.3.6.1.4.1.298.1.3.5.1.1.6OCTET STRINGread-onlymandatory
nodeSummaryTimeStamp
OBJECT-TYPE
nodeSummary entry time stamp (in hundredths of a second) since the network management portion of the system was last re-initialized.
1.3.6.1.4.1.298.1.3.5.1.1.7TimeTicksread-onlymandatory
nodeSecurity
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.5.2
nodeSecuLev1Table
OBJECT-TYPE
Table of nodes which have access to particular ports. Nodes are identified by MAC address.
1.3.6.1.4.1.298.1.3.5.2.1not-accessiblemandatory
nodeSecuLev1Entry
OBJECT-TYPE
Individual entry for node security table.
1.3.6.1.4.1.298.1.3.5.2.1.1not-accessiblemandatory
nodeSecuLev1GrpIndex
OBJECT-TYPE
Group ID for port which verifying node access.
1.3.6.1.4.1.298.1.3.5.2.1.1.1INTEGERread-onlymandatory
nodeSecuLev1PortIndex
OBJECT-TYPE
Specific port for which verifying node access.
1.3.6.1.4.1.298.1.3.5.2.1.1.2INTEGERread-onlymandatory
nodeSecuLev1Status
OBJECT-TYPE
Address is valid or invalid.
1.3.6.1.4.1.298.1.3.5.2.1.1.3INTEGER {other(1), valid(2), invalid(3)}read-writemandatory
nodeSecuLev1AllowedAddr
OBJECT-TYPE
MAC address of nodes allowed for particular port.
1.3.6.1.4.1.298.1.3.5.2.1.1.4PhysAddressread-writemandatory
nodeSecuLev1Action
OBJECT-TYPE
Set action for node intrusion violation.
1.3.6.1.4.1.298.1.3.5.2.1.1.5INTEGER {other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6)}read-writemandatory
concAlarmMgt
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.6
thresholdAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.298.1.3.6.1
thresholdLev1Table
OBJECT-TYPE
Threshold/trap table.
1.3.6.1.4.1.298.1.3.6.1.1not-accessibleoptional
thresholdLev1Entry
OBJECT-TYPE
Individual entry in threshold trap table.
1.3.6.1.4.1.298.1.3.6.1.1.1not-accessibleoptional
thresholdLev1Index
OBJECT-TYPE
An index that uniquely identifies an entry in the alarm table.
1.3.6.1.4.1.298.1.3.6.1.1.1.1INTEGERread-onlyoptional
thresholdLev1Status
OBJECT-TYPE
Status of entry in threshold/trap table.
1.3.6.1.4.1.298.1.3.6.1.1.1.2INTEGER {other(1), valid(2), invalid(3)}read-writeoptional
thresholdLev1Target
OBJECT-TYPE
Set target for threshold definition. Either whole hub(2) or particular port (3).
1.3.6.1.4.1.298.1.3.6.1.1.1.3INTEGER {other(1), hub(2), port(3)}read-writeoptional
thresholdLev1GroupIndex
OBJECT-TYPE
Group ID for trap set. One note--if the target is selected as hub, the group index will be ignored.
1.3.6.1.4.1.298.1.3.6.1.1.1.4INTEGERread-writeoptional
thresholdLev1PortIndex
OBJECT-TYPE
Port number for trap set. One note--if the target is selected as hub, the port index will be ignored.
1.3.6.1.4.1.298.1.3.6.1.1.1.5INTEGERread-writeoptional
thresholdLev1Subject
OBJECT-TYPE
Variable checking for in trap. These are the type of frames that a trap will be verified against.
1.3.6.1.4.1.298.1.3.6.1.1.1.6INTEGER {other(1), readable-frames(2), mcast-frames(3), bcast-frames(4), frame-too-longs(5), runts(6), alignment-errors(7), fragment-errors(8), fCS-errors(9), iFG-errors(10), data-rate-mismatch(11), short-events(12), collisions(13), late-collisions(14), auto-partitions(15), sfd-missing(16), bad-frames(17)}read-writeoptional
thresholdLev1SampleType
OBJECT-TYPE
The method of sampling the selected variable and calculating the value to be compared against the threshold.
1.3.6.1.4.1.298.1.3.6.1.1.1.7INTEGER {other(1), event-per-second(2)}read-writeoptional
thresholdLev1StartupAlarm
OBJECT-TYPE
When the trap is triggered in relation to value set. When goes above (2), below (3), or changes at all from (4).
1.3.6.1.4.1.298.1.3.6.1.1.1.8INTEGER {other(1), rising(2), falling(3), rising-or-falling(4)}read-writeoptional
thresholdLev1WaterMark
OBJECT-TYPE
Counter of threshold.
1.3.6.1.4.1.298.1.3.6.1.1.1.9INTEGERread-writeoptional
thresholdLev1DetectedValue
OBJECT-TYPE
The value of the statistic for the last sampling period.
1.3.6.1.4.1.298.1.3.6.1.1.1.10INTEGERread-onlyoptional
thresholdLev1RisingEvent
OBJECT-TYPE
How to respond to a triggered event for a rising event.
1.3.6.1.4.1.298.1.3.6.1.1.1.11INTEGER {other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6)}read-writeoptional
thresholdLev1FallingEvent
OBJECT-TYPE
How to respond to a triggered event for a falling event.
1.3.6.1.4.1.298.1.3.6.1.1.1.12INTEGER {other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6)}read-writeoptional
thresholdLev1Interval
OBJECT-TYPE
The interval in seconds over which the data is sampled.
1.3.6.1.4.1.298.1.3.6.1.1.1.13INTEGERread-writeoptional
thresholdLev1OwnerString
OBJECT-TYPE
8-byte octet reserved for the owner who defined this entry.
1.3.6.1.4.1.298.1.3.6.1.1.1.14OCTET STRING (SIZE(8))read-writeoptional
productId
OBJECT-IDENTITY
1.3.6.1.4.1.298.2
adapterProductId
OBJECT-IDENTITY
1.3.6.1.4.1.298.2.1
concProductId
OBJECT-IDENTITY
1.3.6.1.4.1.298.2.2
hub1012
OBJECT-IDENTITY
1.3.6.1.4.1.298.2.2.1
hub1012_bridge
OBJECT-IDENTITY
1.3.6.1.4.1.298.2.2.2

Notifications

NameOIDStatus
thresholdLev1
NOTIFICATION-TYPE
The SNMP trap that is generated when an alarm entry crosses its rising threshold or falling threshold, and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.298.2.2.1.0.1
nodeSecuLevel1
NOTIFICATION-TYPE
The SNMP trap that is generated when the MAC layer address of the incoming frame from a particular port does not match the pre-assigned address with that port, and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.298.2.2.1.0.2