ASAM-EQUIP-MIB
- Registered at
- 1.3.6.1.4.1.637.61.1.23
- Namespace
- nokia
- Source file
ASAM-EQUIP-MIB- Digest
sha256:24f491313da8e553c03b469850bf8ed0732c18a912e9cac875b642341ca95fcb
Imports
| From | Symbols |
|---|---|
| ASAM-ALARM-MIB | AsamAlarmSeverityType |
| ASAM-TC-MIB | AsamNextProfileIndex, AsamProfileIndex, AsamProfileName, AsamProfilePointer, AsamProfileRefCount, NetworkTimeInSeconds |
| ITF-MIB | InterfaceIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
| SYSTEM-MIB | asam |
Imported by
3 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ASAM-ALARM-MIB ASAM-EQUIP-MIB ASAM-TC-MIB IANAifType-MIB IF-MIB ITF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC SYSTEM-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| EqptCustAlarmProfileOutputType type | ||||
| EqptCustAlarmProfilePolarityType type | ||||
| EqptHolderIndex type | ||||
| EqptHolderIndexOrZero type | ||||
| EqptPortMappingIndex type | ||||
| EqptPowerRftcIndex type | ||||
| EqptPowerRftcLineStatus type | ||||
| EqptPowerSupplyIndex type | ||||
| EqptSlotIndex type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| asamEquipmentMIB OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23 | |||
| eqptAsam OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.1 | |||
| eqptAsamId OBJECT-TYPE Unique identifier of the system. In practice, this attribute contains the serial number of the most recently equipped SMAS board within the main shelf. Notice however that there are also shelves in which the SMAS is replaced by a GFC board (e.g ARAM-B) or even shelves without SMAS/GFC in which the serial number of the ACU is taken. This attribute is used internally by the system in case both NTs start-up simultaneously to determine whether either the database on NT-A or the database on NT-B should be used as the systems database. It's not the intention to make this attribute visible to an operator. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: '' UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.1 | DisplayString | read-only | mandatory |
| eqptAsamRestart OBJECT-TYPE This attribute is used to restart the system. The persistent data is preserved. Contains previous restart reason, if not available it contains value 255. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: initialValue (255) UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.2 | INTEGER {restartWithSelfTest(1), restartWithoutSelfTest(2), restartHot(5), initialValue(255)} | read-write | mandatory |
| eqptMaxRacksPerAsam OBJECT-TYPE This object is initialized by the system and specifies the maximum number of racks supported by the system. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..7 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.3 | INTEGER | read-only | mandatory |
| eqptMaxShelvesPerRack OBJECT-TYPE This object is initialized by the system and specifies the maximum number of shelves which can be equipped within one rack. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..4 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.4 | INTEGER | read-only | mandatory |
| eqptMaxSlotsPerShelf OBJECT-TYPE This object is initialized by the system and specifies the maximum number of regular slots supported by one shelf. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..22 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.5 | INTEGER | read-only | mandatory |
| eqptHwNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the number of configuration or status changes in the Equipment MIB objects. This counter is incremented each time any of the summary table objects change. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.6 | Counter | read-only | mandatory |
| eqptProtNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the overall number of status changes in the equipment protection MIB objects. This counter is incremented each time any of the eqptProtGroupNumberOfChanges counters is incremented. ALCATEL NOTE: SUPPORT:YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.7 | Counter | read-only | mandatory |
| eqptRestartNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the overall number of status changes in the eqptBoardRestartNumberOfChanges objects in eqptBoardTable. This counter is incremented each time any of the eqptBoardRestartNumberOfChanges counters is incremented. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.8 | Counter | read-only | mandatory |
| eqptFanMode OBJECT-TYPE Parameter indicates the actually applied FAN tray mode: 'default': the fan packs run in average mode, predefined thermal margins are used for defining/adapting the fan speeds 'eco': the fan packs run in 'green' mode, t.i. the most economical mode, minimal thermal margins wrt default settings 'protect': the fan packs run in a heavy mode, t.i. wider thermal margins wrt default settings 'classic': fixed speed settings apply wrt the fan - no SW control ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.1.9 | INTEGER {default(0), eco(1), protect(2), classic(3)} | read-write | mandatory |
| eqptHolderTable OBJECT-TYPE Equipment holder table, representing the system, the racks and the shelves. This table contains one row for the system, one row per rack, and one row per shelf. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.2 | not-accessible | mandatory | |
| eqptHolderEntry OBJECT-TYPE An entry of the equipment holder table. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.2.1 | not-accessible | mandatory | |
| eqptHolderId OBJECT-TYPE Index in equipment holder Table. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.1 | EqptHolderIndex | not-accessible | mandatory |
| eqptHolderClass OBJECT-TYPE Classification of shelves. This object has no meaning for the system and the rack equipment holders. Note: for ISAM, only the values mainEthernet (4) and extEthernet (5) are allowed. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NO RANGE: 1..5 PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.2 | INTEGER {mainIqHcl(1), extIq(2), extHcl(3), mainEthernet(4), extEthernet(5)} | read-write | mandatory |
| eqptHolderPlannedType OBJECT-TYPE A string representing the planned type of equipment holder. If the equipment holder is planned, the string consists of a mnemonic, identifying the holder type. This object is only writable for the entries that represent a shelf. Other entries get a value corresponding to the detected equipment practice type. Following values are valid: System-types: ============= LAUS Large ASAM US market (6 racks, 3 shelves per rack) LAEU Large ASAM EU market (6 racks, 3 shelves per rack) LEEU Large ESAM EU market (7 racks, 4 shelves per rack) LEUS Large ESAM US market (7 racks, 4 shelves per rack) LNEU Large New EquipmentPractise EU market(7 racks, 4 shelves per rack) LEWW Large ESAM World Wide (7 racks, 4 shelves per rack) LNWW Large ESAM World Wide (7 racks, 4 shelves per rack) Rack-types: =========== ALTR-A ADSL Line Termination Rack version A (US) ALTR-E ADSL Line Termination Rack version E (ETSI 2200mm) Shelf-types: ============ <SHELF_MNEMONIC> A shelf of a specific type. Refer to the ETSI Configurations and US Configurations documents for the list of shelf types that are supported in a given system release. NOT_PLANNED The shelf is not planned. NOT_ALLOWED Shelf planning is not allowed in this position. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NO RANGE: See above PERSIST: YES DEFVALUE: 'NOT_PLANNED' UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.3 | DisplayString | read-write | mandatory |
| eqptHolderActualType OBJECT-TYPE A string representing the actual equipment holder type. Following values are possible: <HOLDER_MNEMONIC> Indicates the detected equipment holder-type. Uses same mnemonics as described in object eqptHolderPlannedType. EMPTY Equipment holder is not detected UNKNOWN The type of the detected holder is unknown. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.4 | DisplayString | read-only | mandatory |
| eqptHolderAdminStatus OBJECT-TYPE Used by the administrator to lock or unlock an equipment holder. This attribute is only supported for shelves. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.5 | INTEGER {unlock(1), lock(2)} | read-write | mandatory |
| eqptHolderOperStatus OBJECT-TYPE This attribute identifies whether or not the equipment holder is capable of performing its normal functions. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..2 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.6 | INTEGER {enabled(1), disabled(2)} | read-only | mandatory |
| eqptHolderOperError OBJECT-TYPE This attribute describes for what reason the equipment holder is not operational. These values correspond with the alarms that are generated in case of a failure. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..4, 15 PERSIST: NO DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.7 | INTEGER {no-error(1), type-mismatch(2), holder-missing(3), holder-installation-missing(4), defense(15)} | read-only | mandatory |
| eqptHolderAvailStatus OBJECT-TYPE This attribute indicates whether the equipment holder is available or not. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1, 3, 5, 6 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.8 | INTEGER {available(1), failed(3), notInstalled(5), offLine(6)} | read-only | mandatory |
| eqptHolderDescription OBJECT-TYPE Text-field, which can for instance be used to describe the location of the equipment holder. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: '' UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.9 | DisplayString (SIZE(0..127)) | read-write | mandatory |
| eqptHolderContainerId OBJECT-TYPE This attribute describes in which equipment holder the equipment holder is contained. This object is only meaningful for racks and shelves, since the system itself has no containing equipment holder. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.10 | INTEGER | read-only | mandatory |
| eqptHolderContainerOffset OBJECT-TYPE This attribute describes the position of the equipment holder in the containing equipment holder. This object is only meaningful for racks and shelves, since the system itself has no containing equipment holder. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.11 | INTEGER | read-only | mandatory |
| eqptHolderMode OBJECT-TYPE This attribute identifies the holder mode and is used by both the NEP shelf and the ARAM-E shelf: ntbntio-supported: this mode works in the same manner as iSAM XD. The LSM can only be used on LSM slot. NT in NTB is supported. NTIO is also supported. ntbntio-unsupported: In this mode, NTIO & NTB slot can be used as LT slot. So, two more LSM can be supported in this mode. Therefore, NTIO/NTB board is not supported. ntb-unsupported: In this mode, NTB slot can be used as LT slot. So one more LT can be supported in this mode. Therefore, NTB board will not be supported. This mode is applicable for NFXS-B shelf only. ntio-unsupported: In this mode, there is no NTIO; the slot can be used for an LSM. DEFAULTVALUE: The default Value of the eqptHolderMode depends on the shelf type. In the case of ARAM-E, default will be ntio-unsupported. All other shelves will default to ntbntio-supported mode. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: Yes DEFVALUE: See above UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.12 | INTEGER {ntbntio-supported(1), ntbntio-unsupported(2), ntb-unsupported(3), ntbntioextlt-unsupported(4), ntio-unsupported(6), ngpon-supported(7), gpon-supported(8), ngpon-port-reduced(9)} | read-write | mandatory |
| eqptHolderSerialNumber OBJECT-TYPE This attribute represents the serial number of the shelf. NOT available If FIM < 25 in RI, this attribute could not be retrieved. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.13 | DisplayString | read-only | mandatory |
| eqptHolderVariant OBJECT-TYPE This attribute represents the ALU code of the shelf. NOT available If FIM < 25 in RI, this attribute could not be retrieved. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.14 | DisplayString | read-only | mandatory |
| eqptHolderICScode OBJECT-TYPE This attribute represents the Item Change Status iteration code of the shelf. NOT available If FIM < 25 in RI, this attribute could not be retrieved. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.2.1.15 | DisplayString | read-only | mandatory |
| eqptBoardTable OBJECT-TYPE A table representing the slots of all planned shelves. Each slot can hold a board of one of the following types: NT, EXT, LSM, ACU, CTRL, applique. This table has a row for each slot in each planned shelf. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.3 | not-accessible | mandatory | |
| eqptBoardEntry OBJECT-TYPE An entry in the eqptBoardTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.3.1 | not-accessible | mandatory | |
| eqptSlotId OBJECT-TYPE A unique value to identify a slot position. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.1 | EqptSlotIndex | not-accessible | mandatory |
| eqptSlotPlannedType OBJECT-TYPE A string representing the board (NT, EXT, LSM, ACU, CTRL, Applique) that is planned in the slot. If the board is planned, the string consists of a mnemonic that identifies the board-type. Following mnemonics are valid: <BOARD_MNEMONIC> A board of a specific type. Refer to the ETSI and US Configurations documents for the list of boards that are supported in a given release. ODM board types are planned with the board mnemonic, they are treated as unmanaged boards. EXT_MANAGED The presence of the LT module can be detected but it is not managed by this NT in the HYNT module. The LT type must be planned on the other NT. UNMANAGED Unmanaged board: this means that the presence of the board can be detected and that the board can be reset and powered-down but that it is not possible to establish communication with the board in software. NOT_PLANNED No board is planned in the slot. NOT_ALLOWED Slot planning is not allowed in this position. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 'NOT_PLANNED' UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.2 | DisplayString | read-write | mandatory |
| eqptSlotActualType OBJECT-TYPE A string representing the board (NT, EXT, LSM, ACU, CTRL, Applique) that is actually present in the slot. Following values are possible: <BOARD_MNEMONIC> Indicates the detected board-type. Uses same mnemonics as described in object eqptSlotPlannedType. EMPTY No board plugged within this slot. EXT_MANAGED The presence of the LT module can be detected but it is not managed by this NT in the HYNT module. The LT type must be planned on the other NT. UNMANAGED The type of the detected board is unknown and the planned board type is UNMANAGED or ODMboardtype. UNKNOWN The type of the detected board is unknown and the planned board type is not UNMANAGED and the planned board type is not EXT_MANAGED. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.3 | DisplayString | read-only | mandatory |
| eqptSlotPowerStatus OBJECT-TYPE This attribute is used by the operator to power-up or power-down an LSM slot. This attribute is not supported for other type of slots. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1..2 PERSIST: YES DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.4 | INTEGER {powerUp(1), powerDown(2)} | read-write | mandatory |
| eqptBoardAdminStatus OBJECT-TYPE This attribute is used by the operator to lock or unlock the board. This attribute is only supported for the following type of boards: NT (but notice that the system will refuse a request to lock the NT of a simplex system), EXT and LSM (if managed). This attribute has no meaning for an unmanaged or externally managed (EXT_MANAGED) LSM, for an ACU, CTRL or for an applique. An exception is the NRCD-C, CTRL board of the FD-REM, that has LT capabilities next to the regular CTRL capabilities. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1..2 PERSIST: YES DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.5 | INTEGER {unlock(1), lock(2)} | read-write | mandatory |
| eqptBoardOperStatus OBJECT-TYPE This attribute informs the operator whether the plug-in unit is able to perform its normal operation. This attribute is supported for all type of boards: NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..2 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.6 | INTEGER {enabled(1), disabled(2)} | read-only | mandatory |
| eqptBoardOperError OBJECT-TYPE This attribute describes for what reason the board is not operational. These values correspond with the alarms which are generated in case of a failure. This attribute is supported for all type of boards: NT, EXT, LSM, ACU, CTRL, applique. Default value is no-error, replaced by result from startup sequence. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..15, 255 PERSIST: NO DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.7 | INTEGER {no-error(1), type-mismatch(2), board-missing(3), board-installation-missing(4), no-planned-board(5), waiting-for-sw(6), init-boot-failed(7), init-download-failed(8), init-connection-failed(9), init-configuration-failed(10), board-reset-protection(11), invalid-parameter(12), temperature-alarm(13), tempshutdown(14), defense(15), board-not-licensed(16), sem-power-fail(17), sem-ups-fail(18), board-in-incompatible-slot(19), download-ongoing(21), unknown-error(255)} | read-only | mandatory |
| eqptBoardAvailStatus OBJECT-TYPE This attribute provides further information regarding the state of the board. It is set to available after a successfull selftest of the board (if applicable). This attribute is supported for all type of boards: NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..7 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.8 | INTEGER {available(1), inTest(2), failed(3), powerOff(4), notInstalled(5), offLine(6), dependency(7)} | read-only | mandatory |
| eqptBoardRestart OBJECT-TYPE Writing a valid value to this object will restart the board in the specified mode. This attribute is only supported for the following type of boards: NT, EXT, managed LSM, ACU, CTRL. For ACU and CTRL boards, only a restart without selftest is supported. An exception is the NRCD-C, FD-REM CTRL board, that has LT capabilities (restart with/without selftest) next to the regular CTRL capabilities. Contains previous restart reason, if not available it has value 255. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1, 2, 5, 255 PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.9 | INTEGER {with-selftest(1), without-selftest(2), hot-restart(5), initialValue(255)} | read-write | mandatory |
| eqptBoardSwOverruleStatus OBJECT-TYPE Used to overrule the default software version for this board. This attribute is only supported for managed LSMs. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1..2 PERSIST: NO DEFVALUE: 1 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.10 | INTEGER {no-overrule(1), overrule(2)} | read-write | mandatory |
| eqptBoardContainerId OBJECT-TYPE This attribute describes in which equipment holder the slot is contained. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.11 | INTEGER | read-only | mandatory |
| eqptBoardContainerOffset OBJECT-TYPE This attribute describes the position of the slot in the containing equipment holder. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.12 | INTEGER | read-only | mandatory |
| eqptBoardInventoryAlcatelCompanyId OBJECT-TYPE This attribute represents the company of the board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.13 | DisplayString | read-only | mandatory |
| eqptBoardInventoryTypeName OBJECT-TYPE This attribute represents the name of the board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.14 | DisplayString | read-only | mandatory |
| eqptBoardInventoryPBACode OBJECT-TYPE This attribute represents the Alcatel Printed Board Assembly code of of the board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.15 | DisplayString | read-only | mandatory |
| eqptBoardInventoryFPBACode OBJECT-TYPE This attribute represents the Alcatel Printed Board Assembly code of the board, which also identifies the boot software. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.16 | DisplayString | read-only | mandatory |
| eqptBoardInventoryICScode OBJECT-TYPE This attribute represents the Item Change Status iteration code of the board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.17 | DisplayString | read-only | mandatory |
| eqptBoardInventoryCLEICode OBJECT-TYPE This attribute represents the (USA) Common Language Equipment Identification code of the board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.18 | DisplayString | read-only | mandatory |
| eqptBoardInventorySerialNumber OBJECT-TYPE This attribute represents the serial number of the board. Breakdown of a sample serial number is : sample NANT-D serial number is AA1003ZA028 AA 10 03 ZA028 --- ==== ========== | | |=====' Production Plant Code | | | |==============' Week | |====================' Year ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.19 | DisplayString | read-only | mandatory |
| eqptBoardInventoryLastFailedTest OBJECT-TYPE Identifies the last failing test by means of 4 numbers, from MSB to LSB: - Table number (1 byte) - Segment number (1 byte) - Case number (1 byte) - Check number (1 byte) As long as there has been no failing selftest, the value of this object will be 0. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.20 | OCTET STRING (SIZE(4)) | read-only | mandatory |
| eqptSlotPlannedCapabilityProfile OBJECT-TYPE A pointer to the capability profile that will be used for this slot. Capability profiles are only applicable for LT cards that are not EXT_MANAGED and not UNMANAGED,NRNT-A and NTIO cards. Planning the profile should always be done at the same moment the LT/NTIO is planned. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.22 | AsamProfilePointer | read-write | mandatory |
| eqptBoardCustAlarmProfile OBJECT-TYPE A pointer to the customizable alarms profile which will be associated to NT for all shelves except FD-REM where the customizable alarms profile will be associated to master LT. In redundant NT shelves the profile will be associated to both NTA and NTB while associating customizable alarms profile to NTA or NTB. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.23 | AsamProfilePointer | read-write | mandatory |
| eqptBoardLastRestartCause OBJECT-TYPE This attribute gives the last restart cause for board. Currently only LSM board can support. Considering future safe, only use default value for other board entry. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: unknown UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.24 | INTEGER {poweron(1), unknown(2), watchdog(3), coldreset(4), warmreset(5), hotreset(6), hotreload(7), cleandata(8), emergencybuild(9), poweronreset(10), commitfailure(11), timezonemodified(12)} | read-only | mandatory |
| eqptBoardLastRestartTime OBJECT-TYPE This attribute gives the last restart time. Currently only LSM board can support. Considering future safe, only use default value for other board entry. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.25 | NetworkTimeInSeconds | read-only | mandatory |
| eqptBoardRestartNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the number of restart times. This counter is incremented each time eqptBoardLastRestartTime changes. Considering future safe, only use default value for other board entry. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.26 | Counter | read-only | mandatory |
| eqptBoardRelatedMgntEntityIPAddress OBJECT-TYPE Network address. It is a public OAM IP address related to xVPS. For single OAM IP is introduced, multi-xVPS boards existing on a same shelf may use one single OAM IP. This IP is configured on NT which manages these xVPS boards. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.27 | IpAddress | read-only | mandatory |
| eqptBoardRelatedMgntEntityPairedNumber OBJECT-TYPE For single OAM IP is introduced, one public OAM IP can not identify an xVPS, so community string is introduced. Each active xVPS will have different community string in one shelf. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.28 | INTEGER | read-only | mandatory |
| eqptBoardDualHostIPAddress OBJECT-TYPE Network address. Only applicable for FD REM connected to dual host. It is the public OAM IP address of the host connecting the Lsm in this externally managed slot. It is instantiated with default value and can only be set when the planned type is EXT_MANAGED. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.29 | IpAddress | read-write | mandatory |
| eqptBoardDualHostLsmLocation OBJECT-TYPE Only applicable for FD REM connected to dual host. It is the Rack/Shelf identifying the location of this externally managed slot, within the scope of the host connecting the Lsm. The slot component is implicitly present in the key. It is instantiated with default value and can only be set when the planned type is EXT_MANAGED. The type corresponds to the type EqptHolderIndex, except for the fact that this field can be 0, which is the default value. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.30 | EqptHolderIndexOrZero | read-write | mandatory |
| eqptBoardIfSlotId OBJECT-TYPE This object gives the slot's linear number, which could be used by an external manager to help in mapping a given IfIndex to a physical slot location. It is a numerical value that consists of 6 bits. For a slot that does not carry any interfaces (e.g. applique or NTIO slot), the value is always '0xFF'. Note that this linear slot number is persistent across system restarts, i.e. the same linear slot number will be used for the same slot even after a restart of the ISAM system. However, it is not guaranteed that the same linear slot number will used after a migration to a new release. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 0xFF UNITS: - | 1.3.6.1.4.1.637.61.1.23.3.1.32 | INTEGER | read-only | mandatory |
| eqptBoardRestartCountPerLt OBJECT-TYPE Wrap around counter which indicates the number of restart times per LT. This counter is incremented each time eqptBoardLastRestartTime changes.This counter will reset to zero when LT replaced or unplanned. Note:This counter is Per LT basis. LTs are distinguished based on serialNumber. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: NA | 1.3.6.1.4.1.637.61.1.23.3.1.33 | Counter | read-only | mandatory |
| eqptBoardClearRestartCountPerLt OBJECT-TYPE This object is a button-like object to reset the eqptBoardRestartCountPerLt counter. When it is set to true(1) value then the corresponding eqptBoardRestartCountPerLt counter is cleared. A value set to false(2) or other is ignored.. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: FALSE UNITS: NA | 1.3.6.1.4.1.637.61.1.23.3.1.34 | TruthValue | read-write | mandatory |
| eqptShelfSummaryTable OBJECT-TYPE Shelf summary table, summarizing slot or board related status changes within each shelf. This table has one row per planned shelf. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above. | 1.3.6.1.4.1.637.61.1.23.4 | not-accessible | mandatory | |
| eqptShelfSummaryEntry OBJECT-TYPE An entry of the shelf summary table. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.4.1 | not-accessible | mandatory | |
| eqptShelfHwNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the number of configuration or status changes for slots/boards within this shelf. This counter is incremented each time any of the summary table objects of this shelf changes. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.1 | Counter | read-only | mandatory |
| eqptShelfSlotSummaryOccupation OBJECT-TYPE Bitmap of the occupation of slots (0 = empty, 1 = full) Applicable for NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.2 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptShelfBoardSummaryAdmin OBJECT-TYPE Bitmap of the administrative state of the boards (0 = locked, 1 = unlocked). Applicable for NT, EXT, LSM. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.3 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptShelfBoardSummaryAvail OBJECT-TYPE Bitmap of the availability state of the boards (0 = not available, 1 = available). Applicable for NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.4 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptShelfBoardSummaryOper OBJECT-TYPE Bitmap of the operational state of the boards (0 = locked, 1 = unlocked). Applicable for NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.5 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptShelfBoardSummaryTypeMismatch OBJECT-TYPE Bitmap of the mismatch between the actual board-type and the planned board-type (0 = mismatch, 1 = no mismatch). Applicable for NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.6 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptShelfBoardSummaryAlarm OBJECT-TYPE Bitmap of the boards which generated an alarm (0 = alarm, 1 = no alarm). Applicable for NT, EXT, LSM, ACU, CTRL, applique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.4.1.7 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| eqptProt OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.5 | |||
| eqptProtNextProtGroupId OBJECT-TYPE This object contains an appropriate value to be used for eqptProtGroupId when creating entries in the eqptProtGroupTable. The value 0 indicates that no unassigned entries are available. After each retrieval, the agent will modify the value to the next unassigned index. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.1 | INTEGER | read-only | mandatory |
| eqptProtGroupTable OBJECT-TYPE A table representing groups of protected or protecting elements. Only one row for NT protection group which will always be created and cannot be deleted. From ISAM R4.1.02 the default created NT protection group will be locked. (before it was unlocked). From R3.3 onwards, each LT protection group (comprised of 2 adjacent slots LT n and LT n+1, where n is a odd number), also has a row. The protection groups are created by default even though the protection groups are not used. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.5.2 | not-accessible | mandatory | |
| eqptProtGroupEntry OBJECT-TYPE An entry of the eqptProtGroupTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.5.2.1 | not-accessible | mandatory | |
| eqptProtGroupId OBJECT-TYPE A unique value to identify a protection group. The value 1 is reserved for the NT protection group, which is always present and cannot be deleted. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.1 | INTEGER | not-accessible | mandatory |
| eqptProtGroupType OBJECT-TYPE This attributes distinguishes between 1+1 and 1:N protection groups. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..2 PERSIST: YES DEFVALUE: one-plus-one(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.2 | INTEGER {one-plus-one(1), one-for-N(2)} | read-write | mandatory |
| eqptProtGroupNumberOfChanges OBJECT-TYPE Wrap around counter which indicates the number of status changes in this protection group as well as the status changes for the protecting elements within this group: eqptProtGroupSwitchoverCount; eqptProtGroupLastSwitchoverReason; eqptProtGroupAlarmBitmap; eqptProtElementStandbyStatus. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.3 | Counter | read-only | mandatory |
| eqptProtGroupSwitchoverCount OBJECT-TYPE Wrap around counter for the number of switchovers being performed. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.4 | Counter | read-only | mandatory |
| eqptProtGroupLastSwitchoverReason OBJECT-TYPE This object contains the reason of the last switch over. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..17 PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.5 | INTEGER {noSwitchOver(1), forcedActive(2), boardNotPresent(3), extenderChainFailure(4), linkFailure(5), watchDogTimeOut(6), fileSystemCorrupt(7), configurationMismatch(8), boardUnplanned(9), boardLocked(10), shelfDefense(11), revertiveSwitchOver(12), lanxFailure(13), lanxHwFailure(14), lanxSdkFailure(15), dpoeAppFailure(16), dpoeUnreachable(17)} | read-only | mandatory |
| eqptProtGroupEpsQuenchfactor OBJECT-TYPE This object contains a timervalue in 1/100 sec. The EpsQuench timer is used to prevent continuous switch-overs in case of unstable EPS. Value equal to zero means the quenching mechanism is disabled. Configuration of the EPS quenchfactor has mainly be foreseen for test purposes. Operators should preferably not be able to reconfigure the default value. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: 1440000 UNITS: 0.01 seconds | 1.3.6.1.4.1.637.61.1.23.5.2.1.6 | TimeTicks | read-write | mandatory |
| eqptProtGroupAlarmBitmap OBJECT-TYPE Status bitmap: bit 0 set means No defect at all bit 1 : if bit set, Standby degradation alarm is set (excludes bit 0 setting) bit 2 .. 31 : reserved for future extensions. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0x00000001 UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.7 | INTEGER (1..4294967295) | read-only | mandatory |
| eqptProtGroupAdminStatus OBJECT-TYPE Used by the administrator to disable or enable protection within that protection group. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1..2 PERSIST: YES DEFVALUE: unlock(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.8 | INTEGER {unlock(1), lock(2)} | read-write | mandatory |
| eqptProtGroupAdminProtElement OBJECT-TYPE Only supported for 1:N protection groups. In case of a forced switchover to the spare element, this attribute is used to specify the element to be protected. The value 0 means that no element is specified. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.9 | INTEGER | read-write | mandatory |
| eqptProtGroupOperProtElement OBJECT-TYPE Only supported for 1:N protection groups. Indicates which element is currently protected by the spare element. The value 0 means that currently the spare element is not protecting any element. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.10 | INTEGER | read-only | mandatory |
| eqptProtGroupRowStatus OBJECT-TYPE Entries in the eqptProtGroupTable can only be created at once, by specifying eqptProtGroupRowStatus=createAndGo(4). For NT protection group, if all values are valid then the entry is made active(1). For LT protection group, if the group is in service then the entry is made active(1). If the group is not in service then the entry is made notInService(2). If the object is set to destroy(6), the entry is deleted. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NO for ISAM R3.3 RANGE: See above PERSIST: NO DEFVALUE: active(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.2.1.11 | RowStatus | read-write | mandatory |
| eqptProtElementTable OBJECT-TYPE A table representing the protected or protecting elements. An element can be either a board or an extension chain. Both are identified by the corresponding slot identifier (extension chain is identified by slot of corresponding NT board). This table has only two rows from ISAM R2.2 to R3.2. From R3.3 onwards, this table has a row for each slots in the main shelf. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.5.3 | not-accessible | mandatory | |
| eqptProtElementEntry OBJECT-TYPE An entry of the eqptProtElementTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.5.3.1 | not-accessible | mandatory | |
| eqptProtElementGroupId OBJECT-TYPE This attributes identifies the protection group to which this element belongs. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NO for ISAM R3.3 RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.1 | INTEGER | read-write | mandatory |
| eqptProtElementType OBJECT-TYPE This attribute is used to distinguish between normal elements of a protection group and the spare element of a 1:N protection group. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..2 PERSIST: YES DEFVALUE: normal(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.2 | INTEGER {normal(1), spare(2)} | read-write | mandatory |
| eqptProtElementStandbyStatus OBJECT-TYPE This attribute reflects the standby status of the protection group element. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..4 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.3 | INTEGER {providing-service(1), hot-standby(2), cold-standby(3), idle(4)} | read-only | mandatory |
| eqptProtElementRedcyCtrlStatus OBJECT-TYPE This attribute is used to force a switchover between elements of a protection group or to keep one of the elements active. ALCATEL NOTE: SUPPORT: YES INSRVMOD: YES RANGE: 1..2 PERSIST: YES DEFVALUE: normal(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.4 | INTEGER {normal(1), forced-active(2)} | read-write | mandatory |
| eqptProtElementRowStatus OBJECT-TYPE Entries in the eqptProtElementTable can only be created at once, by specifying eqptProtEelementRowStatus=createAndGo(4). If all values are valid then the entry is made active(1). If the object is set to destroy(6), the entry is deleted. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: active(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.5 | RowStatus | read-write | mandatory |
| eqptProtElementStandbyStatuschangeReason OBJECT-TYPE This attribute reflects the reason why the standby status of the protection group element has changed. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0..24 PERSIST: NO DEFVALUE: none(0) UNITS: - | 1.3.6.1.4.1.637.61.1.23.5.3.1.6 | INTEGER {none(0), protectionGroupLocked(1), forcedActive(2), peerLinkUnAvailable(3), peerLocked(4), peerNotPlanned(5), peerNotPluggedIn(6), databaseNotInSync(7), lanxDynamicDataNotSynced(8), lanxSdkFailure(9), lanxRecovSdkFailure(10), lanxHwFailure(11), lanxDynDataSyncFailure(12), lanxStaticSyncFailure(13), lanxPeerCommFailure(14), lanxFailure(15), linkGroupNotAvailable(16), ltNotEnabled(17), lanxHiGigFailure(18), lanxReconcileFailure(19), lanxDiscoveryFailure(20), dpoeAppFailure(21), dpoeCommFailure(22), dpoeSyncFailure(23), dpoeUnreachable(24)} | read-only | mandatory |
| eqptProfile OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.6 | |||
| eqptProfileTable OBJECT-TYPE A table holding the mapping between the profileId and the corresponding profile name. This table has a row for every profile in the system. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.6.1 | not-accessible | mandatory | |
| eqptProfileEntry OBJECT-TYPE An entry in the eqptProfileTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.6.1.1 | not-accessible | mandatory | |
| eqptProfileId OBJECT-TYPE A value identifying a profile. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.6.1.1.1 | AsamProfileIndex | read-only | mandatory |
| eqptProfileName OBJECT-TYPE The corresponding name for a given profile id. The name corresponding to the ProfileId must also be unique. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.6.1.1.2 | AsamProfileName | read-only | mandatory |
| eqptProfileDescription OBJECT-TYPE A short description for the given profile, explaining the key attributes. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.6.1.1.3 | DisplayString | read-only | mandatory |
| eqptProfileApplicabilityTable OBJECT-TYPE This table lists for every defined profile in the system for which boards it is applicable. One profile can be applicable for multiple board types. Multiple profiles can be applicable for the same board type. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.6.2 | not-accessible | mandatory | |
| eqptProfileApplicabilityEntry OBJECT-TYPE An entry in the eqptProfileApplicabilityTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.6.2.1 | not-accessible | mandatory | |
| eqptBoardType OBJECT-TYPE A string representing the board for which the profile is applicable. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.6.2.1.1 | DisplayString | read-only | mandatory |
| eqptDefaultProfile OBJECT-TYPE A flag indicating if this is the default profile for a specific board type. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.6.2.1.2 | TruthValue | read-only | mandatory |
| eqptTestChainTable OBJECT-TYPE A table contains the test chain configuration indicating which shelf is connected to the TAP_UP or whether an external test head is connected to the TAP_UP. This table has one row for each planned shelf. ALCATEL NOTE: TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.7 | not-accessible | mandatory | |
| eqptTestChainEntry OBJECT-TYPE An entry in the eqptTestChainTable. | 1.3.6.1.4.1.637.61.1.23.7.1 | not-accessible | mandatory | |
| eqptTestChainShelfToTapUp OBJECT-TYPE A unique value to identify a shelf position which is connected to the TAP_UP. The value '0' (default value) indicates that it is not connected. This parameter is used if eqptTestChainExtTestHeadToTapUp is set to '1' (i.e., 'no') and is ignored if eqptTestChainExtTestHeadToTapUp is set to '2' (i.e., 'yes'). ALCATEL NOTE: ACCESS: NA USAGE: OPT PERSIST: YES INSRVMOD: YES RANGE: DEP / 0 plus the range of eqptHolderId of the shelves. DEFVALUE: 0 / this means that no shelf is configured to be connected to the TAP_UP. UNITS: NA SPARSE: NO DESCR: NA | 1.3.6.1.4.1.637.61.1.23.7.1.1 | INTEGER (0..255) | read-write | mandatory |
| eqptTestChainExtTestHeadToTapUp OBJECT-TYPE This parameter is used to indicate whether an external test head is connected to the TAP_UP. no (1): no external test head is connected to the TAP_UP. yes (2): an external test head is connected to the TAP_UP. ALCATEL NOTE: ACCESS: NA USAGE: OPT PERSIST: YES INSRVMOD: YES RANGE: 1..2 DEFVALUE: 1 UNITS: NA SPARSE: NO DESCR: NA | 1.3.6.1.4.1.637.61.1.23.7.1.2 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| eqptCustAlarmProfile OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.8 | |||
| eqptCustAlarmProfileIndexNext OBJECT-TYPE This object contains an appropriate value to be used for eqptCustAlarmProfileIndex when creating entries in the associated profile table. The value 0 indicates that no unassigned entries are available. To obtain the profile index value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. | 1.3.6.1.4.1.637.61.1.23.8.1 | AsamNextProfileIndex | read-only | mandatory |
| eqptCustAlarmProfileTable OBJECT-TYPE A table representing the configurable attributes of the customizable alarms : a description, and the corresponding Alarm Outputs to be activated when this alarm occurs. This table has a row for each external alarms profile. It offers data for a maximum of 5 external alarms. Alarms that are not defined for a particular profile, need to contain default values in the fields corresponding to that alarm number. Independent of the alarm number, the name of the profile is also present, as well as the row status. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.8.2 | not-accessible | mandatory | |
| eqptCustAlarmProfileEntry OBJECT-TYPE An entry in the eqptCustAlarmProfileTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.8.2.1 | not-accessible | mandatory | |
| eqptCustAlarmProfileIndex OBJECT-TYPE The Customizale Alarms Profile Index. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..20 PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.1 | AsamProfileIndex | read-only | mandatory |
| eqptCustAlarmProfileName OBJECT-TYPE A textual name uniquely identifying this profile. Maximum length is 32, allowed characters A-Z, a-z, 0-9, '-'. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.2 | AsamProfileName | read-write | mandatory |
| eqptCustAlarmProfileUsedStatus OBJECT-TYPE Indicates the number of entities using this profile. If the reference count is greater than 0, then this profile is 'in use', and may NOT be deleted. If the value is 0, then this profile is 'not in use', and can be deleted. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.3 | AsamProfileRefCount | read-only | mandatory |
| eqptCustAlarmProfileRowStatus OBJECT-TYPE Entries in the eqptCustAlarmProfileTable can only be created at once, by specifying eqptCustAlarmProfileRowStatus=createAndGo(4). If all values are valid then the entry is made active(1). If the object is set to destroy(6), the entry is deleted. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: active(1) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.4 | RowStatus | read-write | mandatory |
| eqptCustAlarmProfileMnemonic1 OBJECT-TYPE The mnemonic of the customizable alarm, for given Profile Index, for external alarm number 1. Maximum length is 16, allowed characters A-Z. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'UNDEF' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.5 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| eqptCustAlarmProfileDescription1 OBJECT-TYPE The description of the customizable alarm, for given Profile Index, for external alarm number 1. Maximum length is 40. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'Undefined' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.6 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| eqptCustAlarmProfileVisibleOutput1 OBJECT-TYPE Shows whether or not to trigger the visible alarm output, for given Profile Index, for external alarm number 1. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.7 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfileAudibleOutput1 OBJECT-TYPE Shows whether or not to trigger the audible alarm output, for given Profile Index, for external alarm number 1. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.8 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfilePolarity1 OBJECT-TYPE Shows whether the alarm polarity is normal or inversed, for given Profile Index, for external alarm number 1. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: normal(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.9 | EqptCustAlarmProfilePolarityType | read-write | mandatory |
| eqptCustAlarmProfileSeverity1 OBJECT-TYPE Shows the severity of the alarm, for given Profile Index, for external alarm number 1. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: 1-5 PERSIST: YES DEFVALUE: major(4) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.10 | AsamAlarmSeverityType | read-write | mandatory |
| eqptCustAlarmProfileMnemonic2 OBJECT-TYPE The mnemonic of the customizable alarm, for given Profile Index, for external alarm number 2. Maximum length is 16, allowed characters A-Z. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'UNDEF' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.11 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| eqptCustAlarmProfileDescription2 OBJECT-TYPE The description of the customizable alarm, for given Profile Index, for external alarm number 2. Maximum length is 40. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'Undefined' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.12 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| eqptCustAlarmProfileVisibleOutput2 OBJECT-TYPE Shows whether or not to trigger the visible alarm output, for given Profile Index, for external alarm number 2. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.13 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfileAudibleOutput2 OBJECT-TYPE Shows whether or not to trigger the audible alarm output, for given Profile Index, for external alarm number 2. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.14 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfilePolarity2 OBJECT-TYPE Shows whether the alarm polarity is normal or inversed, for given Profile Index, for external alarm number 2. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: normal(2), UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.15 | EqptCustAlarmProfilePolarityType | read-write | mandatory |
| eqptCustAlarmProfileSeverity2 OBJECT-TYPE Shows the severity of the alarm, for given Profile Index, for external alarm number 2. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: 1-5 PERSIST: YES DEFVALUE: major(4) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.16 | AsamAlarmSeverityType | read-write | mandatory |
| eqptCustAlarmProfileMnemonic3 OBJECT-TYPE The mnemonic of the customizable alarm, for given Profile Index, for external alarm number 3. Maximum length is 16, allowed characters A-Z. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'UNDEF' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.17 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| eqptCustAlarmProfileDescription3 OBJECT-TYPE The description of the customizable alarm, for given Profile Index, for external alarm number 3. Maximum length is 40. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'Undefined' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.18 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| eqptCustAlarmProfileVisibleOutput3 OBJECT-TYPE Shows whether or not to trigger the visible alarm output, for given Profile Index, for external alarm number 3. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.19 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfileAudibleOutput3 OBJECT-TYPE Shows whether or not to trigger the audible alarm output, for given Profile Index, for external alarm number 3. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.20 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfilePolarity3 OBJECT-TYPE Shows whether the alarm polarity is normal or inversed, for given Profile Index, for external alarm number 3. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: normal(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.21 | EqptCustAlarmProfilePolarityType | read-write | mandatory |
| eqptCustAlarmProfileSeverity3 OBJECT-TYPE Shows the severity of the alarm, for given Profile Index, for external alarm number 3. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: 1-5 PERSIST: YES DEFVALUE: major(4) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.22 | AsamAlarmSeverityType | read-write | mandatory |
| eqptCustAlarmProfileMnemonic4 OBJECT-TYPE The mnemonic of the customizable alarm, for given Profile Index, for external alarm number 4. Maximum length is 16, allowed characters A-Z. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'UNDEF' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.23 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| eqptCustAlarmProfileDescription4 OBJECT-TYPE The description of the customizable alarm, for given Profile Index, for external alarm number 4. Maximum length is 40. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'Undefined' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.24 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| eqptCustAlarmProfileVisibleOutput4 OBJECT-TYPE Shows whether or not to trigger the visible alarm output, for given Profile Index, for external alarm number 4. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.25 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfileAudibleOutput4 OBJECT-TYPE Shows whether or not to trigger the audible alarm output, for given Profile Index, for external alarm number 4. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.26 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfilePolarity4 OBJECT-TYPE Shows whether the alarm polarity is normal or inversed, for given Profile Index, for external alarm number 4. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: normal(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.27 | EqptCustAlarmProfilePolarityType | read-write | mandatory |
| eqptCustAlarmProfileSeverity4 OBJECT-TYPE Shows the severity of the alarm, for given Profile Index, for external alarm number 4. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: 1-5 PERSIST: YES DEFVALUE: major(4) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.28 | AsamAlarmSeverityType | read-write | mandatory |
| eqptCustAlarmProfileMnemonic5 OBJECT-TYPE The mnemonic of the customizable alarm, for given Profile Index, for external alarm number 5. Maximum length is 16, allowed characters A-Z. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'UNDEF' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.29 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| eqptCustAlarmProfileDescription5 OBJECT-TYPE The description of the customizable alarm, for given Profile Index, for external alarm number 5. Maximum length is 40. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 'Undefined' UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.30 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| eqptCustAlarmProfileVisibleOutput5 OBJECT-TYPE Shows whether or not to trigger the visible alarm output, for given Profile Index, for external alarm number 5. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.31 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfileAudibleOutput5 OBJECT-TYPE Shows whether or not to trigger the audible alarm output, for given Profile Index, for external alarm number 5. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: notTriggered(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.32 | EqptCustAlarmProfileOutputType | read-write | mandatory |
| eqptCustAlarmProfilePolarity5 OBJECT-TYPE Shows whether the alarm polarity is normal or inversed, for given Profile Index, for external alarm number 5. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: normal(2) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.33 | EqptCustAlarmProfilePolarityType | read-write | mandatory |
| eqptCustAlarmProfileSeverity5 OBJECT-TYPE Shows the severity of the alarm, for given Profile Index, for external alarm number 5. ALCATEL NOTE: SUPPORT: NO INSRVMOD: NA RANGE: 1-5 PERSIST: YES DEFVALUE: major(4) UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.2.1.34 | AsamAlarmSeverityType | read-write | mandatory |
| eqptCustAlarmProfileMappingTable OBJECT-TYPE The table listing the profile name to profile Index Mapping. | 1.3.6.1.4.1.637.61.1.23.8.3 | not-accessible | mandatory | |
| eqptCustAlarmProfileMappingEntry OBJECT-TYPE An entry (conceptual row) representing the Customizable Alarm Profile Name to Index mapping. The system automatically creates an entry in this table for each corresponding entry (custAlarm-profile) created in the eqptCustAlarmProfileTable. Similarly, when a profile is deleted, the corresponding entry in this table is also automatically deleted by the system. | 1.3.6.1.4.1.637.61.1.23.8.3.1 | not-accessible | mandatory | |
| eqptCustAlarmProfileMappingName OBJECT-TYPE A textual name uniquely identifying this profile. This name has to be unique within the assigned scope. Maximum length is 32, allowed characters A-Z, a-z, 0-9, '-'. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.3.1.1 | AsamProfileName | not-accessible | mandatory |
| eqptCustAlarmProfileMappingIndex OBJECT-TYPE The Customizale Alarms Profile Index. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..20 PERSIST: YES DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.8.3.1.2 | AsamProfileIndex | read-only | mandatory |
| eqptMtaTest OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.9 | |||
| eqptMtaTestHeadType OBJECT-TYPE setting the MTA test head type, four-wire mode or two-wire mode. This object should be consistent with external test head equipment, MTA subsystem will operate different relays based on this object. MTA commands will have differentiation between these two mode. ALCATEL NOTE: ACCESS: NA USAGE: OPT PERSIST: YES INSRVMOD: YES RANGE: 1..2 DEFVALUE: 1 UNITS: NA SPARSE: NO DESCR: NA | 1.3.6.1.4.1.637.61.1.23.9.1 | INTEGER {four-wire(1), two-wire(2)} | read-write | mandatory |
| eqptBoardThermalSensorTable OBJECT-TYPE A table representing the actual value and thresholds of Thermal Sensor(s) on boards. One entry corresponds to each sensor on board. The entries are presented only when the board is plugged in, operationally up, has thermal sensors on it, and when operator put a read request for it. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.10 | not-accessible | mandatory | |
| eqptBoardThermalSensorEntry OBJECT-TYPE An entry of the equipment thermal sensor table on boards ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.10.1 | not-accessible | mandatory | |
| eqptBoardThermalSensorId OBJECT-TYPE Index of thermal sensors on board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..15 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.10.1.1 | INTEGER | read-only | mandatory |
| eqptBoardThermalSensorActualTemperature OBJECT-TYPE Actual Temperature value read from thermal sensor on board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: -40..150 PERSIST: NO DEFVALUE: NA UNITS: degree Celsius | 1.3.6.1.4.1.637.61.1.23.10.1.2 | INTEGER | read-only | mandatory |
| eqptBoardThermalSensorTcaThresholdLow OBJECT-TYPE Low Tca threshold of thermal sensor on Board ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: degree Celsius | 1.3.6.1.4.1.637.61.1.23.10.1.3 | INTEGER | read-only | mandatory |
| eqptBoardThermalSensorTcaThresholdHigh OBJECT-TYPE High Tca threshold of thermal sensor on Board ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: degree Celsius | 1.3.6.1.4.1.637.61.1.23.10.1.4 | INTEGER | read-only | mandatory |
| eqptBoardThermalSensorShutdownThresholdLow OBJECT-TYPE Low Shutdown threshold of thermal sensor on Board ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: degree Celsius | 1.3.6.1.4.1.637.61.1.23.10.1.5 | INTEGER | read-only | mandatory |
| eqptBoardThermalSensorShutdownThresholdHigh OBJECT-TYPE High Shutdown threshold of thermal sensor on Board ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: degree Celsius | 1.3.6.1.4.1.637.61.1.23.10.1.6 | INTEGER | read-only | mandatory |
| eqptPortMappingTable OBJECT-TYPE Equipment PortMapping table, showing the mapping between logical ports and physical ports (faceplate numbering). This table contains one row per logical port on the xHUB. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.13 | not-accessible | mandatory | |
| eqptPortMappingEntry OBJECT-TYPE An entry of the equipment PortMapping table. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.13.1 | not-accessible | mandatory | |
| eqptPortMappingLogPortNbr OBJECT-TYPE Index in equipment PortMapping Table: corresponds to the logical port id on the xHUB. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.1 | EqptPortMappingIndex | not-accessible | mandatory |
| eqptPortMappingLogPortType OBJECT-TYPE The logical port type corresponds to the link classification. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..4 PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.2 | INTEGER {uplink(1), downlink(2), hostlink(3), internal(4)} | read-only | mandatory |
| eqptPortMappingPhyPortSlot OBJECT-TYPE The equipment slot index of the physical port. This slot will point to either a NT or NTIO slot position. This field is not applicable for hostlinks or internal, in which case it gets the value 0xFFFF ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.3 | EqptSlotIndex | read-only | mandatory |
| eqptPortMappingPhyPortType OBJECT-TYPE The physcial port type. This field is not applicable for hostlinks. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1..3,5,10,11,12,13,14 PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.4 | INTEGER {not-applicable(1), sfp(2), xfp(3), vp(5), eth(10), mcast(11), ai(12), ieee(13), cfp(14)} | read-only | mandatory |
| eqptPortMappingPhyPortNbr OBJECT-TYPE The pysical port number, which corresponds to the faceplate number of the sfp/xfp port. This field is not applicable for hostlinks or internal, in which case it gets the value 0xFF. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.5 | INTEGER | read-only | mandatory |
| eqptPortMappingLSMSlot OBJECT-TYPE The equipment slot index of the corresponding LSM slot. This field is only applicable for hostlinks, and downlinks to which a remote LSM slot is assigned. In other cases it gets the value 0xFFFF. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.6 | EqptSlotIndex | read-only | mandatory |
| eqptPortMappingChanges OBJECT-TYPE This counter represents the number of PortMapping configuration changes per row. It is a wraparound counter between 0 and MAX. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0-MAX PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.13.1.7 | Counter | read-only | mandatory |
| eqptPortMappingGlobalChangeCounter OBJECT-TYPE This counter represents the number of global PortMapping configuration changes. It is a wraparound counter between 0 and MAX. SUPPORT: YES INSRVMOD: NA RANGE: 0-MAX PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.14 | Counter | read-only | mandatory |
| eqptPortProtectionTable OBJECT-TYPE This table holds the port protection groups | 1.3.6.1.4.1.637.61.1.23.15 | not-accessible | mandatory | |
| eqptPortProtectionEntry OBJECT-TYPE This entry represents a protection group which consists of two ports. These two ports can be on the same LT board, or on different LT's. | 1.3.6.1.4.1.637.61.1.23.15.1 | not-accessible | mandatory | |
| eqptPortProtectionPortId OBJECT-TYPE Each row is indexed by the IfIndex of the primary port of the protection group, the one which is protected. Only PON ports can be selected. | 1.3.6.1.4.1.637.61.1.23.15.1.1 | InterfaceIndex | read-only | mandatory |
| eqptPortProtectionRowStatus OBJECT-TYPE All rows instantiated using 'create-and-go' to mate 2 ports in a protection group. Set to 'destroy' to eliminate the protection group. RULE 1 - Cannot create a protection group on an LT card that doesn't support any-to-any redundancy. RULE 2 - Cannot mate two ports in a protection group if the paired port has already one or more interface(s) defined on top of the physical link interface. RULE 3 - Cannot delete a protection group if paired port is Admin UP. | 1.3.6.1.4.1.637.61.1.23.15.1.2 | RowStatus | read-write | mandatory |
| eqptPortProtectionPairedPortId OBJECT-TYPE This attribute represents the IfIndex of the paired port. Only PON ports can be selected. Must satisfy the following VALIDATIONs (otherwise OLT should reject): 1) IfIndex must represent a real port. 2) PON cannot have any provisioned (planned) ONTs. 3) Cannot mate a PON with itself. 4) Cannot mate with a PON that is already mated in a protection scheme. | 1.3.6.1.4.1.637.61.1.23.15.1.3 | InterfaceIndex | read-write | mandatory |
| eqptPortProtectionPortStatus OBJECT-TYPE This attribute represents the status of the primary port. Following DEFINITIONS apply: Active - means the port is used for transmission. Inactive - means the system is NOT using the port for transmission. Up - means the port is capable of being used for transmission/reception. Down - means the port is NOT capable of being used for transmission/reception (this includes a port that is ADMIN down as well as a port that is down due to an operational fault). Enumerations are as follows: 1 = Active Up 2 = Active Down 3 = Inactive Up 4 = Inactive Down | 1.3.6.1.4.1.637.61.1.23.15.1.4 | INTEGER | read-only | mandatory |
| eqptPortProtectionPairedPortStatus OBJECT-TYPE This attribute represents the status of the paired port. Following DEFINITIONS apply: Active - means the port is used for transmission. Inactive - means the system is NOT using the port for transmission. Up - means the port is capable of being used for transmission/reception. Down - means the port is NOT capable of being used for transmission/reception (this includes a port that is ADMIN down as well as a port that is down due to an operational fault). Enumerations are as follows: 1 = Active Up 2 = Active Down 3 = Inactive Up 4 = Inactive Down | 1.3.6.1.4.1.637.61.1.23.15.1.5 | INTEGER | read-only | mandatory |
| eqptPortProtectionSwitchCommand OBJECT-TYPE This attribute represents the IfIndex of the desired port to switch over to. Must satisfy the following VALIDATIONs (otherwise OLT should reject): 1) IfIndex must represent a real port. 2) IfIndex must be part of a protection group. 3) IfIndex must be either the primary or the paired port of the protection group on which the switchover is triggered. | 1.3.6.1.4.1.637.61.1.23.15.1.6 | InterfaceIndex | write-only | mandatory |
| eqptPortProtectionLastSwitchReason OBJECT-TYPE This attribute contains the reason for the last port switchover (if any). 0 = No switch has occurred (since last LT startup). 1 = Manual switch due to port Admin State change. 2 = Manual switch due to usage of Switch command. 3 = Automatic switch due to system determination. 4 = Automatic switch due to LT failure. | 1.3.6.1.4.1.637.61.1.23.15.1.7 | INTEGER | read-only | mandatory |
| eqptPortProtectionNumberOfSwitchovers OBJECT-TYPE This attribute contains the number of switchovers since last LT startup. | 1.3.6.1.4.1.637.61.1.23.15.1.8 | INTEGER | read-only | mandatory |
| eqptPortProtectionLookupTable OBJECT-TYPE This table holds the lookup port protection groups | 1.3.6.1.4.1.637.61.1.23.16 | not-accessible | mandatory | |
| eqptPortProtectionLookupEntry OBJECT-TYPE This entry represents a lookup protection group which consists of two ports. The key is either a primary or a paired port in the eqptPortProtectionTable. | 1.3.6.1.4.1.637.61.1.23.16.1 | not-accessible | mandatory | |
| eqptPortProtectionLookupPortId OBJECT-TYPE Each row is indexed by the IfIndex of a port in a protection group, either a primary or a paired port. Only PON ports can be selected. | 1.3.6.1.4.1.637.61.1.23.16.1.1 | InterfaceIndex | read-only | mandatory |
| eqptPortProtectionLookupPrimaryPortId OBJECT-TYPE This attribute represents the IfIndex of the primary port of the protection group to which the key port belongs. Only PON ports can be selected. | 1.3.6.1.4.1.637.61.1.23.16.1.2 | InterfaceIndex | read-only | mandatory |
| eqptBoardPlannedResourceTable OBJECT-TYPE A table representing the actual values of configured hardware resources on boards. This table only displays entries for resources on the boards that support this view. These are boards for which the relation between HW resource consumption and system configuration is not trivial. If the board is not supporting this view, then no entries will be displayed. The board does not physically need to be present for displaying the resources. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.17 | not-accessible | mandatory | |
| eqptBoardPlannedResourceEntry OBJECT-TYPE An entry of the equipment planned resource table ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.17.1 | not-accessible | mandatory | |
| eqptBoardPlannedResourceId OBJECT-TYPE Index of the planned resource for a board ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.17.1.1 | INTEGER | not-accessible | mandatory |
| eqptBoardPlannedResourceCurrentValue OBJECT-TYPE The actual planned value for the resource ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.17.1.2 | INTEGER | read-only | mandatory |
| eqptBoardPlannedResourceMaxValue OBJECT-TYPE The maximum value that the board supports for this resource. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.17.1.3 | INTEGER | read-only | mandatory |
| eqptBoardPlannedResourceDescription OBJECT-TYPE A string describing the planned resource for this board. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: NA PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.17.1.4 | DisplayString | read-only | mandatory |
| eqptPowerTable OBJECT-TYPE Equipment power table, representing the power management objects per system, rack or shelf. This table contains one row for the system, rack or shelf that is subject to power management. In other cases no entry is instantiated. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.18 | not-accessible | mandatory | |
| eqptPowerEntry OBJECT-TYPE An entry of the equipment power table. An entry will be instantiated for a system/rack or shelf with active power management functionality. At the time of writing VSRM-A shelf (SX) and NGVR (MX) with a planned RANI-B/RPNI-B comply to this requirement. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.18.1 | not-accessible | mandatory | |
| eqptPowerId OBJECT-TYPE Index in equipment Power Table. Index gives the shelf identification. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.1 | EqptHolderIndex | not-accessible | mandatory |
| eqptPowerAdminMode OBJECT-TYPE The eqptPowerAdminMode shows the configured power mode. This configured mode will be used to mask any failures detected for non-supported modes. Enumeration is as follows: 0 = no powermanagement mode configured 1 = AC -> failures on DC local and DC network suppressed 2 = AC + DC local -> failures on DC network suppressed 3 = DC network -> failures on AC or DC local suppressed 4 = DC network + DC local -> failures on AC suppressed 5 = DC local -> failures on DC network or AC suppressed Configuration of the eqptPowerAdminMode is not mandatory and will not impact the behavior of the power module. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.2 | INTEGER {no-powermgnt(0), ac(1), ac-and-dc-local(2), dc-network(3), dc-network-and-dc-local(4), dc-local(5)} | read-write | mandatory |
| eqptPowerOperMode OBJECT-TYPE The eqptPowerOperMode shows the power mode the NE is using at the moment of reading. The VSRM-A (SX) and NGVR (MX) using a power management enabled NTIO (e.g. RANI-B or RPNI-B) will provide valid information for this object. Other systems without Power mode support get no-powermgnt (0). Enumeration is as follows: 0 = system without an active power management 1 = AC 2 = AC + DC local 3 = DC network 4 = DC network + DC local 5 = DC local 6 = Battery fallback, i.e. only battery provides power to the system. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.3 | INTEGER {no-powermgnt(0), ac(1), ac-and-dc-local(2), dc-network(3), dc-network-and-dc-local(4), dc-local(5), battery-fallback(6)} | read-only | mandatory |
| eqptPowerBatType OBJECT-TYPE This object is used to configure the battery type. This configuration only possible for planned powermanagement devices, in this case a planned RANI-B or RPNI-B. Only values for supported battery types are possible (e.g. in R51 only AGM/VRLA Lead Calcium BATTERY (1) is supported for the RANI-B/RPNI-B) The configured value is used to configure the power management driver. The link between the configurable value and the battery type is: 0 = no battery configured 1 = AGM/VRLA Lead Calcium BATTERY 2 = AGM/VRLA Pure Lead BATTERY 3 = FLOODED BATTERY 4 = GEL BATTERY ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.4 | INTEGER {not-configured(0), agm-vrla-PbCa-battery(1), agm-vrla-Pure-Pb-battery(2), flooded-battery(3), gel-battery(4)} | read-write | mandatory |
| eqptPowerBatStartCapacity OBJECT-TYPE The capacity (Ah) of the battery at the moment of installation. The value of the capacity is in 1/100 Ah. Instatiated when eqptPowerBatType is configured. The configuration of this object is mandatory together with the configuration of the eqptPowerBatType ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 1000 .. 10000 PERSIST: YES DEFVALUE: 1000 UNITS: 1/10O Ah | 1.3.6.1.4.1.637.61.1.23.18.1.5 | INTEGER | read-write | mandatory |
| eqptPowerBatPlannedLifetime OBJECT-TYPE Planned lifetime of the installed battery in 1/10 year. The planned lifetime, together with the start capacity, is used to calculate the actual maximal capacity of the battery. Instatiated when eqptPowerBatType is configured. The configuration of this object is mandatory together with the configuration of the eqptPowerBatType ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0 .. 150 PERSIST: YES DEFVALUE: 0 UNITS: 1/10 Year | 1.3.6.1.4.1.637.61.1.23.18.1.6 | INTEGER | read-write | mandatory |
| eqptPowerBatState OBJECT-TYPE The battery state will provide a view on the state of the battery. Possible states are: charging, charged and discharging. This operational state has meaning for devices that have a configured eqptPowerBatType. Other devices get a not-configured (0) value returned. Enumeration is as follows: 1 = no data available, e.g. battery configured, but not connected 2 = charging 3 = charged 4 = discharging ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.7 | INTEGER {not-configured(0), no-data(1), charging(2), charged(3), discharging(4)} | read-only | mandatory |
| eqptPowerBatFailure OBJECT-TYPE The battery failure state will provide an view on the failure state of the battery. This failure state has meaning for devices that have a configured eqptPowerBatType and eqptPowerBatState different from default or no-data. Other devices get a not-applicable (0) value returned. Specific ranges for the failure cases strongly depend on the battery type used. The ranges will be detailed in the customer documentation. Enumeration is as follows: 0 = not applicable 1 = voltage good 2 = voltage out of range 3 = over-voltage 4 = over-temperature alarm on local temperature sensor 5 = battery depleted ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.8 | INTEGER {not-applicable(0), voltage-good(1), voltage-out-of-range(2), over-voltage(3), over-temperature(4), battery-depleted(5)} | read-only | mandatory |
| eqptPowerBatTemperature OBJECT-TYPE Measured temperature of the battery in 1/10 Celcius The value is only readable when the battery type (eqptPowerBatType) is configured and the battery is installed and reachable. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: -1000 .. 1000 PERSIST: NO DEFVALUE: 0 UNITS: 1/10 Celcius | 1.3.6.1.4.1.637.61.1.23.18.1.9 | INTEGER | read-only | mandatory |
| eqptPowerBatActualCapacity OBJECT-TYPE The capacity (in % of a fully charged battery) of the battery. The value is only readable when the battery type (eqptPowerBatType) is configured and the battery is installed and reachable. Default value of 0% is returned when the battery is not reachable. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0 - 100 PERSIST: NO DEFVALUE: 0 UNITS: % | 1.3.6.1.4.1.637.61.1.23.18.1.10 | INTEGER | read-only | mandatory |
| eqptPowerBatDefenseMode OBJECT-TYPE The battery defense modes offers the operator the possibility to select the preferred power defense mode in case the system falls back to the battery mode. The power defense mode is a way to optimize the power consumption. In R5001 two options are possible. In later releases additional defense modes will be introduced. - no battery defense. In this mode the system will run normally, offering regular service until the battery runs out and the regular hw defenses are started (Dying Gasp) - voice priority. In this mode when the system falls back to the battery the regular service will be maintained until the battery drains until 90% and will then give priority to the voice LT's by powering down the DSL LT's. Voice service will be maintained until the battery runs out and the regular hw defenses are started (Dying Gasp). This configuration only possible for planned powermanagement devices, in this case a planned RANI-B or RPNI-B. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: YES DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.11 | INTEGER {no-defense(0), voice-priority(1)} | read-write | mandatory |
| eqptPowerBatDefenseThreshold OBJECT-TYPE The threshold gives an indication of the remaining capacity of the battery at the moment the defense defined in eqptPowerBatDefenseMode should be started. The value is in %. In the default case the configured defense mode is immediately activated. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0-100 PERSIST: YES DEFVALUE: 80 UNITS: % | 1.3.6.1.4.1.637.61.1.23.18.1.12 | INTEGER | read-write | mandatory |
| eqptPowerACState OBJECT-TYPE The AC power state will provide an view on the state of the AC Power supply. The value is different from no-powermgnt (0) for devices with power management functionality and AC input available. Enumeration is as follows: 0 = no-powermgnt 1 = active 2 = active-failure, i.e. in failure, but still providing power 3 = failure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.13 | INTEGER {no-powermgnt(0), active(1), active-failure(2), failure(3)} | read-only | mandatory |
| eqptPowerACFailure OBJECT-TYPE The AC failure state will provide an view on the failure state of the AC power supply. This failure state has meaning when eqptPowerACstate different from default. In other cases not-applicable (0) is returned. Specific ranges for the failure cases strongly depend on the AC power used. The ranges will be detailed in the customer documentation. Enumeration is as follows: 0 = not-applicable 1 = voltage good 2 = voltage out of range ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.14 | INTEGER {not-applicable(0), voltage-good(1), voltage-out-of-range(2)} | read-only | mandatory |
| eqptPowerNDCaState OBJECT-TYPE The NDCa (Network DC a) state will provide an view on the state of the Network DC Power supply. The value is different from no-powermgnt (0) for devices with power management functionality and NDC a input available. Enumeration is as follows: 0 = no-powermgnt 1 = active 2 = active-failure, i.e. in failure, but still providing power 3 = failure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.15 | INTEGER {no-powermgnt(0), active(1), active-failure(2), failure(3)} | read-only | mandatory |
| eqptPowerNDCaFailure OBJECT-TYPE The NDCa failure state will provide an view on the failure state of the Network DC a power supply. This failure state has meaning when eqptPowerNDCaState different from default. In other cases not-applicable (0) is returned. Specific ranges for the failure cases strongly depend on the DC power used. The ranges will be detailed in the customer documentation. Enumeration is as follows: 0 = not-applicable 1 = voltage-good 2 = low-voltage 3 = under-voltage ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.16 | INTEGER {not-applicable(0), voltage-good(1), low-voltage(2), under-voltage(3)} | read-only | mandatory |
| eqptPowerNDCbState OBJECT-TYPE The NDCb (Network DC a) state will provide an view on the state of the Network DC b power supply. The value is different from no-powermgnt (0) for devices with power management functionality and NDC b input available. Enumeration is as follows: 0 = no-powermgnt 1 = active 2 = active-failure, i.e. in failure, but still providing power 3 = failure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.17 | INTEGER {no-powermgnt(0), active(1), active-failure(2), failure(3)} | read-only | mandatory |
| eqptPowerNDCbFailure OBJECT-TYPE The NDCb failure state will provide an view on the failure state of the Network DC b power supply. This failure state has meaning when eqptPowerNDCbState different from default. In other cases not-applicable (0) is returned. Specific ranges for the failure cases strongly depend on the DC power used. The ranges will be detailed in the customer documentation. Enumeration is as follows: 0 = not-applicable 1 = voltage-good 2 = low-voltage 3 = under-voltage ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.18 | INTEGER {not-applicable(0), voltage-good(1), low-voltage(2), under-voltage(3)} | read-only | mandatory |
| eqptPowerLDCaState OBJECT-TYPE The LDCa power state will provide an view on the state of the local DC a power supply. The value is different from no-powermgnt (0) for devices with power management functionality and LDC a input available. Enumeration is as follows: 0 = no-powermgnt 1 = active 2 = active-failure, i.e. in failure, but still providing power 3 = failure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.19 | INTEGER {no-powermgnt(0), active(1), active-failure(2), failure(3)} | read-only | mandatory |
| eqptPowerLDCaFailure OBJECT-TYPE The LDCa failure state will provide an view on the failure state of the local DC a power supply. This failure state has meaning when eqptPowerLDCaState different from default. In other cases not-applicable (0) is returned. Enumeration is as follows: 0 = not-applicable 1 = voltage good 2 = voltage out of range ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.20 | INTEGER {not-applicable(0), voltage-good(1), voltage-out-of-range(2)} | read-only | mandatory |
| eqptPowerLDCbState OBJECT-TYPE The LDCb power state will provide an view on the state of the local DC b power suply. The value is different from no-powermgnt (0) for devices with power management functionality and LDC b input available. Enumeration is as follows: 0 = no-powermgnt 1 = active 2 = active-failure, i.e. in failure, but still providing power 3 = failure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.21 | INTEGER {no-powermgnt(0), active(1), active-failure(2), failure(3)} | read-only | mandatory |
| eqptPowerLDCbFailure OBJECT-TYPE The LDCb failure state will provide an view on the failure state of the local DC b power supply. This failure state has meaning when eqptPowerLDCbState different from default. In other cases not-applicable (0) is returned. Enumeration is as follows: 0 = not-applicable 1 = voltage good 2 = voltage out of range ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: 0 UNITS: - | 1.3.6.1.4.1.637.61.1.23.18.1.22 | INTEGER {not-applicable(0), voltage-good(1), voltage-out-of-range(2)} | read-only | mandatory |
| eqptPowerInVoltage OBJECT-TYPE Measured incoming voltage in 1/10 Volt Only supported for devices that host an extended power management function (e.g RANI-B and RPNI-B). ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0 .. 2650 PERSIST: NO DEFVALUE: 0 UNITS: 1/10 Volt | 1.3.6.1.4.1.637.61.1.23.18.1.23 | INTEGER | read-only | mandatory |
| eqptPowerInCurrent OBJECT-TYPE Measured incoming current in 1/10 Ampere Only supported for devices that host an extended power management function (e.g RANI-B and RPNI-B). ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0 .. 60 PERSIST: NO DEFVALUE: 0 UNITS: 1/10 Ampere | 1.3.6.1.4.1.637.61.1.23.18.1.24 | INTEGER | read-only | mandatory |
| eqptPowerInConsumedPower OBJECT-TYPE Calculated incoming consumed power in 1/10 Watt Only supported for devices that host an extended power management function (e.g RANI-B and RPNI-B). ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: 0 .. 6000 PERSIST: NO DEFVALUE: 0 UNITS: 1/10 Watt | 1.3.6.1.4.1.637.61.1.23.18.1.25 | INTEGER | read-only | mandatory |
| eqptPowerSupplyTable OBJECT-TYPE Equipment power table, representing the power suplly management objects This table contains one row per power supply supported on the system. In other cases no entry is instantiated. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.19 | not-accessible | mandatory | |
| eqptPowerSupplyEntry OBJECT-TYPE An entry of the equipment power table. An entry will be instantiated per power supply supported on the system. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.19.1 | not-accessible | mandatory | |
| eqptPowerSupplyId OBJECT-TYPE Index in equipment Power Supply Table. This is a number representing the Nth power supply present in the system. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.1 | EqptPowerSupplyIndex | not-accessible | mandatory |
| eqptPowerSupplyPartNumber OBJECT-TYPE Report the part number of the installed power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.2 | OCTET STRING (SIZE(13)) | read-only | mandatory |
| eqptPowerSupplyCleiCode OBJECT-TYPE Report the CLEI code of the installed power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.3 | OCTET STRING (SIZE(11)) | read-only | mandatory |
| eqptPowerSupplySerNumber OBJECT-TYPE Report the serial number of the installed power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.4 | OCTET STRING (SIZE(19)) | read-only | mandatory |
| eqptPowerSupplyVin OBJECT-TYPE Report the incoming voltage arriving at the power supply in millivolt ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.5 | INTEGER | read-only | mandatory |
| eqptPowerSupplyIin OBJECT-TYPE Report the incoming current arriving at the power supply in milliampere ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.6 | INTEGER | read-only | mandatory |
| eqptPowerSupplyVout OBJECT-TYPE Report the output voltage provided by the power supply in millivolt ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.7 | INTEGER | read-only | mandatory |
| eqptPowerSupplyIout OBJECT-TYPE Report the output current provided by the power supply in milliampere ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.8 | INTEGER | read-only | mandatory |
| eqptPowerSupplyTemperature OBJECT-TYPE Report the temperature of the power supply in millidegree ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.9 | INTEGER | read-only | mandatory |
| eqptPowerSupplyFaultVin OBJECT-TYPE Report the fault or warning occurring for the input voltage ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.10 | INTEGER {no-error(0), input-overvoltage-fault(1), input-overvoltage-warning(2), input-undervoltage-warning(3), input-undervoltage-fault(4), input-ac-nok-fault(5), input-ac-nok-warning(6), unit-off-for-insufficient-input-voltage(7)} | read-only | mandatory |
| eqptPowerSupplyFaultVout OBJECT-TYPE Report the fault or warning occurring for the output voltage ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.11 | INTEGER {no-error(0), output-overvoltage-fault(1), output-overvoltage-warning(2), output-undervoltage-warning(3), output-undervoltage-fault(4)} | read-only | mandatory |
| eqptPowerSupplyFaultIin OBJECT-TYPE Report the fault or warning occurring for the input current ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.12 | INTEGER {no-error(0), input-overcurrent-fault(1), input-overcurrent-warning(2), input-overpower-warning(3)} | read-only | mandatory |
| eqptPowerSupplyFaultIout OBJECT-TYPE Report the fault or warning occurring for the output current ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.13 | INTEGER {no-error(0), output-overcurrent-fault(1), output-overcurrent-warning(2), output-undercurrent-warning(3), output-undercurrent-fault(4)} | read-only | mandatory |
| eqptPowerSupplyFaultTemperature OBJECT-TYPE Report the fault or warning occurring for the tempertaure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.14 | INTEGER {no-error(0), overtemperature-fault(1), overtemperature-warning(2), undertemperature-warning(3), undertemperature-fault(4)} | read-only | mandatory |
| eqptPowerSupplyFaultCml OBJECT-TYPE Report the fault or warning occurring for the tempertaure ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.15 | INTEGER {no-error(0), invalid-or-unsupported-command-received(1), invalid-or-unsupported-data-received(2), packet-error-check-failed(3), memory-fault-detected(4), processor-fault-detected(5), other-communication-fault(6), other-memory-or-logic-fault(7)} | read-only | mandatory |
| eqptPowerSupplyPresent OBJECT-TYPE Report if the power supply is present. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.16 | INTEGER {yes(0), no(1)} | read-only | mandatory |
| eqptPowerSupplyFaultDetected OBJECT-TYPE Report if a fault has been detected. If yes, then eqptPowerSupplyFaultVin, eqptPowerSupplyFaultVout, eqptPowerSupplyFaultIin, eqptPowerSupplyFaultIOut, eqptPowerSupplyFaultTemperature or eqptPowerSupplyFaultCml is reporting an error. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.19.1.17 | INTEGER {no(0), yes(1)} | read-only | mandatory |
| eqptPowerSupplyRftc OBJECT-IDENTITY | 1.3.6.1.4.1.637.61.1.23.20 | |||
| eqptPowerRftcTable OBJECT-TYPE Equipment RFT-C power table, representing the RFT-C management objects This table contains one row per RFT-C module supported on the system. In other cases no entry is instantiated. ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.20.1 | not-accessible | mandatory | |
| eqptPowerRftcEntry OBJECT-TYPE An entry of the equipment RFT-C power table. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.20.1.1 | not-accessible | mandatory | |
| eqptPowerRftcId OBJECT-TYPE Index in equipment Power RFT-C Table. This is a number represents the shelf containting the RFT-C module. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.1 | EqptHolderIndex | read-only | mandatory |
| eqptPowerRftcVCommon OBJECT-TYPE Report the common voltage arriving at the power supply in millivolt ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: mV | 1.3.6.1.4.1.637.61.1.23.20.1.1.2 | INTEGER | read-only | optional |
| eqptPowerRftcICommon OBJECT-TYPE Report the common current arriving at the power supply in milliampere ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: mA | 1.3.6.1.4.1.637.61.1.23.20.1.1.3 | INTEGER | read-only | optional |
| eqptPowerRftcTHotspot OBJECT-TYPE Report the temperature of the power supplys hotspot in degrees celcius ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: °C | 1.3.6.1.4.1.637.61.1.23.20.1.1.4 | INTEGER | read-only | optional |
| eqptPowerRftcTAmbient OBJECT-TYPE Report the ambient temperature of the power supply in degrees celcius ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: °C | 1.3.6.1.4.1.637.61.1.23.20.1.1.5 | INTEGER | read-only | optional |
| eqptPowerRftcSWVersion OBJECT-TYPE Report the software version of the RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.6 | DisplayString | read-only | optional |
| eqptPowerRftcHWVersion OBJECT-TYPE Report the hardware version of the RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.7 | DisplayString | read-only | optional |
| eqptPowerRftcHWRevision OBJECT-TYPE Report hardware revision of the RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.8 | INTEGER | read-only | optional |
| eqptPowerRftcSerialnumber OBJECT-TYPE Report serial number of the RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.9 | DisplayString | read-only | optional |
| eqptPowerRftcManufacturer OBJECT-TYPE Report the manufacturer code of the RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.10 | DisplayString | read-only | optional |
| eqptPowerRftcLineCount OBJECT-TYPE Report the number of lines used on this RFT-C power supply ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.1.1.11 | INTEGER | read-only | optional |
| eqptPowerRftcLineTable OBJECT-TYPE ALCATEL NOTE: SUPPORT: YES TABLESIZE: DEP as described above | 1.3.6.1.4.1.637.61.1.23.20.2 | not-accessible | mandatory | |
| eqptPowerRftcLineEntry OBJECT-TYPE An entry in the eqptPowerRftcLineTable. ALCATEL NOTE: SUPPORT: YES | 1.3.6.1.4.1.637.61.1.23.20.2.1 | not-accessible | mandatory | |
| eqptPowerRftcLineId OBJECT-TYPE Report the line number ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.2.1.1 | INTEGER | read-only | mandatory |
| eqptPowerRftcLineStatus OBJECT-TYPE Report the line status. ALCATEL NOTE: SUPPORT: YES INSRVMOD: NA RANGE: See above PERSIST: NO DEFVALUE: NA UNITS: - | 1.3.6.1.4.1.637.61.1.23.20.2.1.2 | EqptPowerRftcLineStatus | read-only | mandatory |