ARUBAWIRED-POWERSUPPLY-MIB
- Registered at
- 1.3.6.1.4.1.47196.4.1.1.3.11.2
- Last updated
- 2020-01-07 00:00
- Organization
- HPE/Aruba Networking Division
- Revisions
- 2020-01-07 00:00
- Namespace
- arubaos
- Source file
ARUBAWIRED-POWERSUPPLY-MIB- Digest
sha256:fe25d4d679071ada6e74c75343a9f7f636a1f1fcb0b93db305810cae89f5d7c8
Description
This MIB module describes management objects that manage Power Supply Units.
Contact
Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747
Imports
| From | Symbols |
|---|---|
| ARUBAWIRED-CHASSIS-MIB | arubaWiredChassisMIB |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ARUBAWIRED-CHASSIS-MIB ARUBAWIRED-NETWORKING-OID ARUBAWIRED-POWERSUPPLY-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| arubaWiredPSUNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.47196.4.1.1.3.11.2.0 | |||
| arubaWiredPowerSupplyTable OBJECT-TYPE This table contains one row per switch power supply entity. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1 | not-accessible | current | |
| arubaWiredPowerSupplyEntry OBJECT-TYPE Information about the power supply physical entity table. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1 | not-accessible | current | |
| arubaWiredPSUGroupIndex OBJECT-TYPE This variable uniquely identifies the group containing the power supply. Group means chassis in the stack and the value 1 MUST be used for non-modular devices. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.1 | Integer32 (1..2147483647) | read-only | current |
| arubaWiredPSUSlotIndex OBJECT-TYPE This variable uniquely identifies the power supply in a chassis and value 1 must be used for non-modular devices. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.2 | Integer32 (1..2147483647) | read-only | current |
| arubaWiredPSUName OBJECT-TYPE Identification of the power supply for the system. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.3 | DisplayString (SIZE(0..20)) | read-only | current |
| arubaWiredPSUState OBJECT-TYPE Current status for the power supply. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.4 | DisplayString (SIZE(0..20)) | read-only | current |
| arubaWiredPSUProductName OBJECT-TYPE Power supply product name identification. This field is used to determine if the power supply is supported. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.5 | DisplayString (SIZE(0..20)) | read-only | current |
| arubaWiredPSUSerialNumber OBJECT-TYPE Power supply serial number to uniquely identify the power supply. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.6 | DisplayString (SIZE(0..20)) | read-only | current |
| arubaWiredPSUInstantaneousPower OBJECT-TYPE Total instantaneous power supplied by the power supply in Watts. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.7 | Integer32 | read-only | current |
| arubaWiredPSUMaximumPower OBJECT-TYPE Total maximum power capacity that can be supplied by the power supply in Watts. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.8 | Integer32 | read-only | current |
| arubaWiredPSUNumberFailures OBJECT-TYPE Number of failures the power supply has experienced since the most recent insertion of the power supply and boot of the system. The number of failures for a power supply will be cleared if the power supply is removed from the system or if the system is rebooted. For non removable power supplies, the number of failures will not clear until the system reboots. Failures are any events where power delivery from the power supply did not occur when expected. This includes unsupported power supply types since their power delivery is not considered valid even though the power supply itself may not have an internal failure. Some examples of failures are over current, invalid input power, and unsupported power supply type. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.9 | Integer32 | read-only | current |
| arubaWiredPSUAirflowDirection OBJECT-TYPE Power Supply airflow direction. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.1.1.10 | DisplayString (SIZE(0..20)) | read-only | current |
| arubaWiredPowerSupplyConformance OBJECT-IDENTITY | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99 | |||
| arubaWiredPowerSupplyCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99.1 | |||
| arubaWiredPowerSupplyGroups OBJECT-IDENTITY | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| arubaWiredPSUStateNotification NOTIFICATION-TYPE A notification generated when a PSU state change occurs. This can happen if a PSU is powerd on, powerd off, inserted, removed, or exeriences a fault. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.0.1 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| arubaWiredPowerSupplyCompliance MODULE-COMPLIANCE A compliance statement for Aruba switch chassis. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99.1.1 | current |
| arubaWiredPowerSupplyTableGroup OBJECT-GROUP A collection of objects display configuration, status, and measurements of Power Supply table. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99.2.1 | current |
| arubaWiredPSUNotificationsGroup NOTIFICATION-GROUP Notifications sent by power management. | 1.3.6.1.4.1.47196.4.1.1.3.11.2.99.2.2 | current |