MIBs Depot

ARISTA-PFC-MIB

Registered at
1.3.6.1.4.1.30065.3.11
Last updated
2014-08-15 00:00
Organization
Arista Networks, Inc.
Revisions
2014-08-15 00:00, 2013-02-28 00:00
Namespace
arista
Source file
ARISTA-PFC-MIB
Digest
sha256:e1a35c07f2ccf2d521ab19448a595fb426de657c0474d13dca6a42b48414efda

Description

Extensions for managing IEEE 802.1Qbb Priority-based Flow Control on Arista devices. This module extends IEEE8021-PFC-MIB by providing per class-of-service information for the supported Arista platforms.

Contact

Arista Networks, Inc. Postal: 5453 Great America Parkway Santa Clara, CA 95054 Tel: +1 408 547-5500 E-mail: snmp@arista.com

Imports

FromSymbols
ARISTA-SMI-MIBaristaMibs
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ARISTA-PFC-MIB
ARISTA-SMI-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AristaPfcCOSIndex
TEXTUAL-CONVENTION
A unique value for each Ethernet class-of-service priority
current

Objects

NameOIDSyntaxAccessStatus
aristaPfc
OBJECT-IDENTITY
1.3.6.1.4.1.30065.3.11.1
aristaPfcPriorityTable
OBJECT-TYPE
This table contains the per class-of-service priority-flow-control information of an interface.
1.3.6.1.4.1.30065.3.11.1.1not-accessiblecurrent
aristaPfcPriorityEntry
OBJECT-TYPE
A list of attributes of each ingress class-of-service of an interface.
1.3.6.1.4.1.30065.3.11.1.1.1not-accessiblecurrent
aristaPfcIfIndex
OBJECT-TYPE
The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
1.3.6.1.4.1.30065.3.11.1.1.1.1InterfaceIndexnot-accessiblecurrent
aristaPfcPriorityIndex
OBJECT-TYPE
The Ethernet class-of-service index for accessing the per-priority information of an interface.
1.3.6.1.4.1.30065.3.11.1.1.1.2AristaPfcCOSIndexnot-accessiblecurrent
aristaPfcPriorityRequests
OBJECT-TYPE
A count of the invoked PFC M_CONTROL.request primitives with this priority class asserted. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
1.3.6.1.4.1.30065.3.11.1.1.1.3Counter64read-onlycurrent
aristaPfcPriorityIndications
OBJECT-TYPE
A count of the received PFC M_CONTROL.indication primitives with this priority class asserted. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
1.3.6.1.4.1.30065.3.11.1.1.1.4Counter64read-onlycurrent
aristaPfcConformance
OBJECT-IDENTITY
1.3.6.1.4.1.30065.3.11.2
aristaPfcCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.30065.3.11.2.1
aristaPfcGroups
OBJECT-IDENTITY
1.3.6.1.4.1.30065.3.11.2.2

Conformance

NameOIDStatus
aristaPfcCompliance
MODULE-COMPLIANCE
The compliance statement for Arista switches that support Priority Flow Control (PFC).
1.3.6.1.4.1.30065.3.11.2.1.1current
aristaPfcGroup
OBJECT-GROUP
The group of required PFC objects.
1.3.6.1.4.1.30065.3.11.2.2.1current