Description

This management information module supports the configuration and management of SONET linear APS groups. The definitions and descriptions used in this mib have been derived from Synchronous Optical Network (SONET) Transport Systems: Common Generic Criteria, GR-253-CORE Revision 2, January 1999, section 5.3. The MIB is also consistent with the Multiplex Section Protection (MSP) protocol as specified in ITU-T Recommendation G.783, Characteristics of synchronous digital hierarchy (SDH) equipment function blocks, Annex A and B.

Contact

Jeff Johnson Postal: RedBack Networks. Inc. 350 Holger Way San Jose, CA 95134-1362 Tel: +1 408 571 5460 Email: jeff@redback.com Michael Thatcher Postal: RedBack Networks. Inc. 350 Holger Way San Jose, CA 95134-1362 Tel: +1 408 571 5449 Email: thatcher@redback.com Jim Kuhfeld Postal: RedBack Networks. Inc. 350 Holger Way San Jose, CA 95134-1362 Tel: +1 408 571 5465 Email: jkuhfeld@redback.com

Imports

FromSymbols
IF-MIBInterfaceIndex
Juniper-ExperimentjuniSonetApsExperiment
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

APS-MIB-JUNI
IANAifType-MIB
IF-MIB
Juniper-Experiment
Juniper-UNI-SMI
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
JunidApsControlCommand
TEXTUAL-CONVENTION
An APS control command applies only to LTE that support the 1:n architecture and performs the following actions. The Control command values are: noCmd This value should be returned by a read request when no control command has been written to the object in question since initialization. This value may not be used in a write operation. lockoutWorkingChannel Prevents the specified working channel from switching to the protection line. clearLockoutWorkingChannel Clears the lockout a working channel command for the channel specified.
current
JunidApsK1K2
TEXTUAL-CONVENTION
This Textual Convention describes an object that stores a SONET K1 and K2 byte APS protocol field. K1 is located in the first octet, K2 is located in the second octet. Bits are numbered from left to right. Bits 1-4 of the K1 byte indicate a request. 1111 Lockout of Protection 1110 Forced Switch 1101 SF - High Priority 1100 SF - Low Priority 1011 SD - High Priority 1010 SD - Low Priority 1001 not used 1000 Manual Switch 0111 not used 0110 Wait-to-Restore 0101 not used 0100 Exercise 0011 not used 0010 Reverse Request 0001 Do Not Revert 0000 No Request Bits 5-8 of the K1 byte indicate the channel associated with the request defined in bits 1-4. 0000 is the Null channel. 1-14 are working channels. 15 is the extra traffic channel Bits 1-4 of the K2 byte indicate a channel. The channel is defined with the same syntax as K1 Bits 5-8. Bit 5 of the K2 byte indicates the architecture. 0 if the architecture is 1+1 1 if the architecture is 1:n Bits 6-8 of the K2 byte indicates the mode. 000 - 011 are reserved for future use 100 indicates the mode is unidirectional 101 indicates the mode is bidirectional 110 RDI-L 111 AIS-L
current
JunidApsSwitchCommand
TEXTUAL-CONVENTION
An APS switch command allows a user to perform protection switch actions. The Switch command values are: noCmd This value should be returned by a read request when no switch command has been written to the object in question since initialization. This value may not be used in a write operation. clear Clears all of the switch commands listed below for the specified channel. lockoutOfProtection Prevents any of the working channels from switching to the protection line. The specified channel should be the protection channel. forcedSwitchWorkToProtect Switches the specified working channel to the protection line. forcedSwitchProtectToWork Switches the working channel back from the protection line to the working line. The specified channel should be the protection channel. manualSwitchWorkToProtect Switches the specified working channel to the protection line. manualSwitchProtectToWork Switches the working channel back from the protection line to the working line. The specified channel should be the protection channel. exercise Exercises the protocol for a protection switch of the specified channel by issuing an Exercise request for that channel and checking the response on the APS channel.
current

Objects

NameOIDSyntaxAccessStatus
junidApsMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.1
junidApsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.1.1
junidApsConfigGroups
OBJECT-TYPE
The count of APS groups. This count includes all rows in junidApsConfigTable.
1.3.6.1.4.1.4874.3.2.2.1.1.1.1Gauge32read-onlycurrent
junidApsConfigTable
OBJECT-TYPE
This table lists the APS groups that have been configured on the system.
1.3.6.1.4.1.4874.3.2.2.1.1.1.2not-accessiblecurrent
junidApsConfigEntry
OBJECT-TYPE
A conceptual row in the junidApsConfigTable.
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1not-accessiblecurrent
junidApsConfigName
OBJECT-TYPE
A textual name for the APS group.
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.1SnmpAdminString (SIZE(1..32))not-accessiblecurrent
junidApsConfigRowStatus
OBJECT-TYPE
The status of this APS group entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value. Also, all associated junidApsChanConfigEntry rows must represent a set of consecutive channel numbers beginning with 0 or 1, depending on the selected architecture. When set to notInService changes may be made to junidApsConfigMode, junidApsConfigRevert, junidApsConfigDirection, junidApsConfigExtraTraffic, junidApsConfigSdBerThreshold, junidApsConfigSfBerThreshold, and junidApsConfigWaitToRestore. Also, associated junidApsChanConfigTable objects may be added, deleted and modified.
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.2RowStatusread-createcurrent
junidApsConfigMode
OBJECT-TYPE
The architecture of the APS group. onePlusOne The 1+1 architecture permanently bridges the working line to the protection line. oneToN The 1:n architecture allows one protection channel to protect up to n working channels. When a fault is detected on one of the n working channels that channel is bridged over the protection channel. onePlusOneCompatible This refers to 1 + 1 bidirectional switching compatible with 1:n bidirectional switching as specified in ITU-T Recommendation G.783 (04/97) section A.3.4.1. Since this mode necessitates bidirectional switching, junidApsConfigDirection must be set to bidirectional whenever onePlusOneCompatible is set. onePlusOneOptimized This refers to 1 + 1 bidirectional switching optimized for a network using predominantly 1 + 1 bidirectional switching as specified in ITU-T Recommendation G.783 (04/97) section B.1. Since this mode necessitates bidirectional switching, junidApsConfigDirection must be set to bidirectional whenever onePlusOneOptimized is set. This object may not be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.3INTEGER {onePlusOne(1), oneToN(2), onePlusOneCompatible(3), onePlusOneOptimized(4)}read-createcurrent
junidApsConfigRevert
OBJECT-TYPE
The revertive mode of the APS group. nonrevertive Traffic remains on the protection line until another switch request is received. revertive When the condition that caused a switch to the protection line has been cleared the signal is switched back to the working line. Since switching is revertive with the 1:n architecture, junidApsConfigRevert must be set to revertive if junidApsConfigMode is set to oneToN. Switching may optionally be revertive with the 1+1 architecture. This object may not be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.4INTEGER {nonrevertive(1), revertive(2)}read-createcurrent
junidApsConfigDirection
OBJECT-TYPE
The directional mode of the APS group. unidirectional The unidirectional mode provides protection in one direction. bidirectional The bidirectional mode provides protection in both directions. This object may not be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.5INTEGER {unidirectional(1), bidirectional(2)}read-createcurrent
junidApsConfigExtraTraffic
OBJECT-TYPE
This object enables or disables the transfer of extra traffic on the protection channel in a 1:n architecture. This object must be set to disabled if the architecture is 1+1. It may be necessary to disable this in order to interwork with other SONET network elements that don't support extra traffic. This object may not be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.6INTEGER {enabled(1), disabled(2)}read-createcurrent
junidApsConfigSdBerThreshold
OBJECT-TYPE
The Signal Degrade Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5. This object may be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.7Integer32 (5..9)read-createcurrent
junidApsConfigSfBerThreshold
OBJECT-TYPE
The Signal Failure Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5. This object may be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.8Integer32 (3..5)read-createcurrent
junidApsConfigWaitToRestore
OBJECT-TYPE
The Wait To Restore period in seconds. After clearing of a condition that necessitated an automatic switch, the wait to restore period must elapse before reverting. This is intended to avoid rapid switch oscillations. GR-253-CORE specifies a Wait To Restore range of 5 to 12 minutes. G.783 defines a 5 to 12 minute Wait To Restore range in section 5.4.1.1.3, but also allows for a shorter WTR period in Table 2-1, WaitToRestore value (MI_WTRtime: 0..(5)..12 minutes). This object may not be modified if the associated junidApsConfigRowStatus object is equal to active(1).
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.9Integer32 (0..720)read-createcurrent
junidApsConfigCreationTime
OBJECT-TYPE
The value of sysUpTime at the time the row was created
1.3.6.1.4.1.4874.3.2.2.1.1.1.2.1.10TimeStampread-onlycurrent
junidApsStatusTable
OBJECT-TYPE
This table provides status information about APS groups that have been configured on the system.
1.3.6.1.4.1.4874.3.2.2.1.1.2not-accessiblecurrent
junidApsStatusEntry
OBJECT-TYPE
A conceptual row in the junidApsStatusTable. Entries in this table are created as a side effect of row addition in junidApsConfigTable.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1not-accessiblecurrent
junidApsStatusK1K2Rcv
OBJECT-TYPE
The current value of the K1 and K2 bytes received on the protection channel.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.1JunidApsK1K2read-onlycurrent
junidApsStatusK1K2Trans
OBJECT-TYPE
The current value of the K1 and K2 bytes transmitted on the protection channel.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.2JunidApsK1K2read-onlycurrent
junidApsStatusCurrent
OBJECT-TYPE
The current status of the APS group. modeMismatch Modes other than 1+1 unidirectional monitor protection line K2 bit 5, which indicates the architecture and K2 bits 6-8, which indicate if the mode is unidirectional or bidirectional. A conflict between the current local mode and the received K2 mode information constitutes a mode mismatch. channelMismatch This bit indicates a mismatch between the transmitted K1 channel and the received K2 channel has been detected. psbf This bit indicates a Protection Switch Byte Failure (PSBF) is in effect. This condition occurs when either an inconsistent APS byte or an invalid code is detected. An inconsistent APS byte occurs when no three consecutive K1 bytes of the last 12 successive frames are identical, starting with the last frame containing a previously consistent byte. An invalid code occurs when the incoming K1 byte contains an unused code or a code irrelevant for the specific switching operation (e.g., Reverse Request while no switching request is outstanding) in three consecutive frames. An invalid code also occurs when the incoming K1 byte contains an invalid channel number in three consecutive frames. feplf Modes other than 1+1 unidirectional monitor the K1 byte for Far-End Protection-Line failures. A Far-End Protection-Line defect is declared based on receiving SF on the protection line. extraTraffic This bit indicates whether extra traffic is currently being accepted on the protection line.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.3Bits {modeMismatch(0), channelMismatch(1), psbf(2), feplf(3), extraTraffic(4)}read-onlycurrent
junidApsStatusModeMismatches
OBJECT-TYPE
A count of Mode Mismatch conditions.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.4Counter32read-onlycurrent
junidApsStatusChannelMismatches
OBJECT-TYPE
A count of Channel Mismatch conditions.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.5Counter32read-onlycurrent
junidApsStatusPSBFs
OBJECT-TYPE
A count of Protection Switch Byte Failure conditions. This condition occurs when either an inconsistent APS byte or an invalid code is detected. An inconsistent APS byte occurs when no three consecutive K1 bytes of the last 12 successive frames are identical, starting with the last frame containing a previously consistent byte. An invalid code occurs when the incoming K1 byte contains an unused code or a code irrelevant for the specific switching operation (e.g., Reverse Request while no switching request is outstanding) in three consecutive frames. An invalid code also occurs when the incoming K1 byte contains an invalid channel number in three consecutive frames.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.6Counter32read-onlycurrent
junidApsStatusFEPLFs
OBJECT-TYPE
A count of Far-End Protection-Line Failure conditions. This condition is declared based on receiving SF on the protection line in the K1 byte.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.7Counter32read-onlycurrent
junidApsStatusSwitchedChannel
OBJECT-TYPE
This field is set to the number of the channel that is currently switched to protection. The value 0 indicates no channel is switched to protection. The values 1-14 indicate that working channel is switched to protection.
1.3.6.1.4.1.4874.3.2.2.1.1.2.1.8Integer32read-onlycurrent
junidApsMap
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.1.3
junidApsChanLTEs
OBJECT-TYPE
The count of SONET LTE interfaces on the system. Each interface that is included has an ifType value of sonet(39).
1.3.6.1.4.1.4874.3.2.2.1.1.3.1Gauge32read-onlycurrent
junidApsMapTable
OBJECT-TYPE
This table lists the SONET LTE interfaces on the system. Each interface that is listed has an ifType value of sonet(39).
1.3.6.1.4.1.4874.3.2.2.1.1.3.2not-accessiblecurrent
junidApsMapEntry
OBJECT-TYPE
A conceptual row in the junidApsMapTable.
1.3.6.1.4.1.4874.3.2.2.1.1.3.2.1not-accessiblecurrent
junidApsMapIfIndex
OBJECT-TYPE
The Interface Index assigned to a SONET LTE. This is an interface with ifType sonet(39).
1.3.6.1.4.1.4874.3.2.2.1.1.3.2.1.1InterfaceIndexnot-accessiblecurrent
junidApsMapGroupName
OBJECT-TYPE
A textual name for the APS group which this channel is included in. If the channel is not part of an APS group this value is set to a string of size 0. When an instance of junidApsChanConfigIfIndex is set equal to an instance of junidApsMapIfIndex, junidApsMapGroupName is set equal to the corresponding value of junidApsChanConfigGroupName. If the junidApsMapIfIndex ceases to be equal to an instance of junidApsChanConfigIfIndex, either because of a change in the value of junidApsChanConfigIfIndex, or because of row deletion in the junidApsChanConfigTable, junidApsMapGroupName is set to a string of size 0.
1.3.6.1.4.1.4874.3.2.2.1.1.3.2.1.2SnmpAdminString (SIZE(0..32))read-onlycurrent
junidApsMapChanNumber
OBJECT-TYPE
This field is set to a unique channel number within an APS group. The value 0 indicates the null channel. The values 1-14 define a working channel. If the SONET LTE is not part of an APS group this value is set to -1. When an instance of junidApsChanConfigIfIndex is set equal to an instance of junidApsMapIfIndex, junidApsMapChanNumber is set equal to the corresponding value of junidApsChanConfigNumber. If the junidApsMapIfIndex ceases to be equal to an instance of junidApsChanConfigIfIndex, either because of a change in the value of junidApsChanConfigIfIndex, or because of row deletion in the junidApsChanConfigTable, junidApsMapChanNumber is set to -1.
1.3.6.1.4.1.4874.3.2.2.1.1.3.2.1.3Integer32 (-1..14)read-onlycurrent
junidApsChanConfigTable
OBJECT-TYPE
This table lists the APS channels that have been configured in APS groups.
1.3.6.1.4.1.4874.3.2.2.1.1.4not-accessiblecurrent
junidApsChanConfigEntry
OBJECT-TYPE
A conceptual row in the junidApsChanConfigTable.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1not-accessiblecurrent
junidApsChanConfigGroupName
OBJECT-TYPE
A textual name for the APS group which this channel is included in.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1.1SnmpAdminString (SIZE(1..32))not-accessiblecurrent
junidApsChanConfigNumber
OBJECT-TYPE
This field is set to a unique channel number within an APS group. The value 0 indicates the null channel. The values 1-14 define a working channel. This field must be assigned a unique number within the group.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1.2Integer32 (0..14)not-accessiblecurrent
junidApsChanConfigRowStatus
OBJECT-TYPE
The status of this APS channel entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value. A row in the junidApsChanConfigTable may not be created, deleted, set to notInService or otherwise modified if the junidApsChanConfigGroupName value is equal to an junidApsConfigName value and the associated junidApsConfigRowStatus object is equal to active. However, if the junidApsConfigRowStatus object is equal to notInService, a row may be created, deleted or modified. In other words, a channel may not be added, deleted or modified if the group is active. A row may be created with an junidApsChanConfigGroupName value that is not equal to any existing instance of junidApsConfigName. This action is the initial step in adding a SONET LTE to a new APS group. If this object is set to destroy, the associated instance of junidApsMapGroupName will be set to a string of size 0 and the junidApsMapChanNumber will be set to -1. The channel status entry will also be deleted by this action. junidApsChanConfigNumber must be set to a unique channel number within the APS group. The value 0 indicates the null channel. The values 1-14 define a working channel. When an attempt is made to set the corresponding junidApsConfigRowStatus field to active the junidApsChanConfigNumber values of all entries with equal junidApsChanConfigGroupName fields must represent a set of consecutive integer values beginning with 0 or 1, depending on the architecture of the group, and ending with n, where n is greater than or equal to 1 and less than or equal to 14. Otherwise, the error inconsistentValue is returned to the junidApsConfigRowStatus set attempt.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1.3RowStatusread-createcurrent
junidApsChanConfigIfIndex
OBJECT-TYPE
The Interface Index assigned to a SONET LTE. This is an interface with ifType sonet(39). The value of this object must be unique among all instances of junidApsChanConfigIfIndex. In other words, a particular SONET LTE can only be configured in one APS group. This object cannot be set if the junidApsChanConfigGroupName instance associated with this row is equal to an instance of junidApsConfigName and the corresponding junidApsConfigRowStatus object is set to active. In other words this value cannot be changed if the APS group is active. However, This value may be changed if the junidApsConfigRowStatus value is equal to notInService.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1.4InterfaceIndexread-createcurrent
junidApsChanConfigPriority
OBJECT-TYPE
The priority of the channel. This field deterimines whether high or low priority SD and SF codes are used in K1 requests. This field is only applicable if the channel is to be included in a group using the 1:n architecture. It is not applicable if the channel is to be included in a group using the 1+1 architecture, and is ignored in that case. This object cannot be set if the junidApsChanConfigGroupName instance associated with this row is equal to an instance of junidApsConfigName and the corresponding junidApsConfigRowStatus object is set to active. In other words this value cannot be changed if the APS group is active. However, This value may be changed if the junidApsConfigRowStatus value is equal to notInService.
1.3.6.1.4.1.4874.3.2.2.1.1.4.1.5INTEGER {low(1), high(2)}read-createcurrent
junidApsCommandTable
OBJECT-TYPE
This table allows commands to be sent to configured APS groups.
1.3.6.1.4.1.4874.3.2.2.1.1.5not-accessiblecurrent
junidApsCommandEntry
OBJECT-TYPE
A conceptual row in the junidApsCommandTable. This row exists only if the associated junidApsConfigEntry is active.
1.3.6.1.4.1.4874.3.2.2.1.1.5.1not-accessiblecurrent
junidApsCommandSwitch
OBJECT-TYPE
Allows the initiation of an APS switch command on the APS group and channel specified by the index values. If the APS switch command cannot be executed because an equal or higer priority request is in effect, an error is returned. When read this object returns the last command written or noCmd if no command has been written to this channel since initialization. The return of the last command written does not imply that this command is currently in effect. This request may have been preempted by a higher priority local or remote request. In order to determine the current state of the APS group it is necessary to read the objects junidApsStatusK1K2Rcv and junidApsStatusK1K2Trans. The value lockoutOfProtection should only be applied to the protection line channel since that switch command prevents any of the working channels from switching to the protection line. Following the same logic, forcedSwitchProtectToWork and manualSwitchProtectToWork should only be applied to the protection line channel. forcedSwitchWorkToProtect and manualSwitchWorkToProtect should only be applied to a working channel.
1.3.6.1.4.1.4874.3.2.2.1.1.5.1.1JunidApsSwitchCommandread-writecurrent
junidApsCommandControl
OBJECT-TYPE
Allows the initiation of an APS control command on the APS group and channel specified by the index values. When read this object returns the last command written or noCmd if no command has been written to this channel since initialization. This object does not apply to the protection line.
1.3.6.1.4.1.4874.3.2.2.1.1.5.1.2JunidApsControlCommandread-writecurrent
junidApsChanStatusTable
OBJECT-TYPE
This table contains status information for all SONET LTE interfaces that are included in APS groups.
1.3.6.1.4.1.4874.3.2.2.1.1.6not-accessiblecurrent
junidApsChanStatusEntry
OBJECT-TYPE
A conceptual row in the junidApsChanStatusTable. A row in this table is created as a side effect of row addition in the junidApsChanConfigTable. The junidApsChanStatusTable row exists as long as the junidApsChanConfigTable entry exists, regardless of whether the associated junidApsChanConfigRowStatus is active.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1not-accessiblecurrent
junidApsChanStatusCurrent
OBJECT-TYPE
Indicates the current state of the port. lockedOut This bit, when applied to a working channel, indicates that the channel is prevented from switching to the protection line. When applied to the null channel, this bit indicates that no working channel may switch to the protection line. sd A signal degrade condition is in effect. sf A signal failure condition is in effect. switched The switched bit is applied to a working channel if that channel is currently switched to the protection line.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.1Bits {lockedOut(0), sd(1), sf(2), switched(3)}read-onlycurrent
junidApsChanStatusSignalDegrades
OBJECT-TYPE
A count of Signal Degrade conditions. This condition occurs when the line Bit Error Rate exceeds the currently configured threshold.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.2Counter32read-onlycurrent
junidApsChanStatusSignalFailures
OBJECT-TYPE
A count of Signal Failure conditions that have been detected on the incoming signal. This condition occurs when a loss of signal, loss of frame, AIS-L or a Line bit error rate exceeding 10^-3 is detected on an incoming line.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.3Counter32read-onlycurrent
junidApsChanStatusSwitchovers
OBJECT-TYPE
The number of times this channel has switched to the protection line. When queried with index value junidApsChanConfigNumber set to 0, which is the protection line, this object will return 0.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.4Counter32read-onlycurrent
junidApsChanStatusLastSwitchover
OBJECT-TYPE
The value of sysUpTime when this channel last completed a switch to the protection line. If this channel has never switched to the protection line, or this channel is the protection line, the value 0 will be returned.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.5TimeStampread-onlycurrent
junidApsChanStatusSwitchoverSeconds
OBJECT-TYPE
The cumulative Protection Switching Duration (PSD) time in seconds. For a working channel, this is the cumulative number of seconds that service was carried on the protection line. For the protection line, this is the cumulative number of seconds that the protection line has been used to carry any working channel traffic. This information is only valid if revertive switching is enabled. The value 0 will be returned otherwise.
1.3.6.1.4.1.4874.3.2.2.1.1.6.1.6Counter32read-onlycurrent
junidApsMIBNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.2
junidApsNotificationsPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.2.0
junidApsMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.3
junidApsGroups
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.3.1
junidApsCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.4874.3.2.2.1.3.2

Notifications

NameOIDStatus
junidApsEventSwitchover
NOTIFICATION-TYPE
An junidApsEventSwitchover notification is sent when the value of an instance of junidApsChanStatusSwitchovers increments.
1.3.6.1.4.1.4874.3.2.2.1.2.0.1current
junidApsEventModeMismatch
NOTIFICATION-TYPE
An junidApsEventModeMismatch notification is sent when the value of an instance of junidApsStatusModeMismatches increments.
1.3.6.1.4.1.4874.3.2.2.1.2.0.2current
junidApsEventChannelMismatch
NOTIFICATION-TYPE
An junidApsEventChannelMismatch notification is sent when the value of an instance of junidApsStatusChannelMismatches increments.
1.3.6.1.4.1.4874.3.2.2.1.2.0.3current
junidApsEventPSBF
NOTIFICATION-TYPE
An junidApsEventPSBF notification is sent when the value of an instance of junidApsStatusPSBFs increments.
1.3.6.1.4.1.4874.3.2.2.1.2.0.4current
junidApsEventFEPLF
NOTIFICATION-TYPE
An junidApsEventFEPLFs notification is sent when the value of an instance of junidApsStatusFEPLFs increments.
1.3.6.1.4.1.4874.3.2.2.1.2.0.5current

Conformance

NameOIDStatus
junidApsConfigGeneral
OBJECT-GROUP
A collection of junidApsConfigTable objects providing configuration information applicable to all linear APS groups.
1.3.6.1.4.1.4874.3.2.2.1.3.1.1current
junidApsConfigWtr
OBJECT-GROUP
The junidApsConfigTable object that provides information which is applicable to groups supporting a configurable WTR period.
1.3.6.1.4.1.4874.3.2.2.1.3.1.2current
junidApsCommandOnePlusOne
OBJECT-GROUP
The junidApsCommandTable object which is applicable to groups implementing the linear APS 1+1 architecture. Also, set operations must be supported.
1.3.6.1.4.1.4874.3.2.2.1.3.1.3current
junidApsCommandOneToN
OBJECT-GROUP
A collection of junidApsCommandTable objects which are applicable to groups implementing the linear APS 1:n architecture. Also, set operations must be supported.
1.3.6.1.4.1.4874.3.2.2.1.3.1.4current
junidApsStatusGeneral
OBJECT-GROUP
A collection of junidApsStatusTable objects providing status information applicable to all linear APS groups.
1.3.6.1.4.1.4874.3.2.2.1.3.1.5current
junidApsChanGeneral
OBJECT-GROUP
A collection of channel objects providing information applicable to all linear APS channels.
1.3.6.1.4.1.4874.3.2.2.1.3.1.6current
junidApsChanOneToN
OBJECT-GROUP
The junidApsChanConfigTable object that provides information which is only applicable to groups implementing the linear APS 1:n architecture.
1.3.6.1.4.1.4874.3.2.2.1.3.1.7current
junidApsTotalsGroup
OBJECT-GROUP
A collection of objects providing optional counts of configured APS groups and SONET LTE interfaces.
1.3.6.1.4.1.4874.3.2.2.1.3.1.8current
junidApsMapGroup
OBJECT-GROUP
A collection of junidApsMapTable objects providing a mapping from sonet(39) InterfaceIndex to group name and channel number for assigned APS channels and a list of unassigned sonet(39) interfaces.
1.3.6.1.4.1.4874.3.2.2.1.3.1.9current
junidApsEventOptional
NOTIFICATION-GROUP
A collection of SONET linear APS notifications that may optionally be implemented.
1.3.6.1.4.1.4874.3.2.2.1.3.1.10current
junidApsCompliance
MODULE-COMPLIANCE
The compliance statement for linear APS groups.
1.3.6.1.4.1.4874.3.2.2.1.3.2.1current