ALTIGA-HARDWARE-STATS-MIB
- Registered at
- 1.3.6.1.4.1.3076.1.1.27.21.3.6.1.4.1.3076.2.1.2.22.1
- Last updated
- 2003-03-27 13:00
- Organization
- Cisco Systems, Inc.
- Revisions
- 2003-03-27 13:00, 2002-09-05 13:00, 2002-07-10 00:00
- Namespace
- cisco
- Source file
ALTIGA-HARDWARE-STATS-MIB- Digest
sha256:7638325781e4f977d173c73ef67b92bf67d133f589b3cfebba8247f7d301f2ed
Description
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
Contact
Cisco Systems 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cvpn3000@cisco.com
Imports
| From | Symbols |
|---|---|
| ALTIGA-GLOBAL-REG | alHardwareMibModule |
| ALTIGA-MIB | alHardwareGroup, alStatsHardware |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ALTIGA-GLOBAL-REG ALTIGA-HARDWARE-STATS-MIB ALTIGA-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ConcentratorCard TEXTUAL-CONVENTION Concentrator Card Type. | current | |||
| ConcentratorType TEXTUAL-CONVENTION Concentrator Type indicates the chassis type. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| altigaHardwareStatsMibConformance OBJECT-IDENTITY | 1.3.6.1.4.1.3076.1.1.27.2.1 | |||
| altigaHardwareStatsMibCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.3076.1.1.27.2.1.1 | |||
| alStatsHardwareGlobal OBJECT-IDENTITY | 1.3.6.1.4.1.3076.2.1.2.22.1 | |||
| alHardwareCpuVoltage OBJECT-TYPE The current CPU voltage in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.1 | Gauge32 | read-only | current |
| alHardwareCpuVoltageAlarm OBJECT-TYPE The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.2 | TruthValue | read-only | current |
| alHardwareCpuVoltageCount OBJECT-TYPE The number of alarm events for CPU voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.3 | Counter32 | read-only | current |
| alHardwareCpuVoltageTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for CPU voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.4 | TimeTicks | read-only | current |
| alHardwarePs1Voltage3v OBJECT-TYPE The current 3V voltage of Power Supply 1 in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.5 | Gauge32 | read-only | current |
| alHardwarePs1Voltage3vAlarm OBJECT-TYPE The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.6 | TruthValue | read-only | current |
| alHardwarePs1Voltage3vCount OBJECT-TYPE The number of alarm events for PS1 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.7 | Counter32 | read-only | current |
| alHardwarePs1Voltage3vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for PS1 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.8 | TimeTicks | read-only | current |
| alHardwarePs1Voltage5v OBJECT-TYPE The current 5V voltage of Power Supply 1 in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.9 | Gauge32 | read-only | current |
| alHardwarePs1Voltage5vAlarm OBJECT-TYPE The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.10 | TruthValue | read-only | current |
| alHardwarePs1Voltage5vCount OBJECT-TYPE The number of alarm events for PS1 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.11 | Counter32 | read-only | current |
| alHardwarePs1Voltage5vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for PS1 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.12 | TimeTicks | read-only | current |
| alHardwarePs2Voltage3v OBJECT-TYPE The current 3V voltage of Power Supply 2 in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.13 | Gauge32 | read-only | current |
| alHardwarePs2Voltage3vAlarm OBJECT-TYPE The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.14 | TruthValue | read-only | current |
| alHardwarePs2Voltage3vCount OBJECT-TYPE The number of alarm events for PS2 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.15 | Counter32 | read-only | current |
| alHardwarePs2Voltage3vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for PS2 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.16 | TimeTicks | read-only | current |
| alHardwarePs2Voltage5v OBJECT-TYPE The current 5V voltage of Power Supply 2 in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.17 | Gauge32 | read-only | current |
| alHardwarePs2Voltage5vAlarm OBJECT-TYPE The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.18 | TruthValue | read-only | current |
| alHardwarePs2Voltage5vCount OBJECT-TYPE The number of alarm events for PS2 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.19 | Counter32 | read-only | current |
| alHardwarePs2Voltage5vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for PS2 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.20 | TimeTicks | read-only | current |
| alHardwareBoardVoltage3v OBJECT-TYPE The current 3V voltage of the mainboard in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.21 | Gauge32 | read-only | current |
| alHardwareBoardVoltage3vAlarm OBJECT-TYPE The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.22 | TruthValue | read-only | current |
| alHardwareBoardVoltage3vCount OBJECT-TYPE The number of alarm events for the mainboard 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.23 | Counter32 | read-only | current |
| alHardwareBoardVoltage3vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.24 | TimeTicks | read-only | current |
| alHardwareBoardVoltage5v OBJECT-TYPE The current 5V voltage of the mainboard in centivolts. | 1.3.6.1.4.1.3076.2.1.2.22.1.25 | Gauge32 | read-only | current |
| alHardwareBoardVoltage5vAlarm OBJECT-TYPE The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.26 | TruthValue | read-only | current |
| alHardwareBoardVoltage5vCount OBJECT-TYPE The number of alarm events for the mainboard 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.27 | Counter32 | read-only | current |
| alHardwareBoardVoltage5vTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage. | 1.3.6.1.4.1.3076.2.1.2.22.1.28 | TimeTicks | read-only | current |
| alHardwareCpuTemp OBJECT-TYPE The current CPU temperature in degrees C. | 1.3.6.1.4.1.3076.2.1.2.22.1.29 | Integer32 (-40..120) | read-only | current |
| alHardwareCpuTempAlarm OBJECT-TYPE The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.30 | TruthValue | read-only | current |
| alHardwareCpuTempCount OBJECT-TYPE The number of alarm events for the CPU temperature. | 1.3.6.1.4.1.3076.2.1.2.22.1.31 | Counter32 | read-only | current |
| alHardwareCpuTempTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for the CPU temperature. | 1.3.6.1.4.1.3076.2.1.2.22.1.32 | TimeTicks | read-only | current |
| alHardwareCageTemp OBJECT-TYPE The current cage temperature in degrees C. | 1.3.6.1.4.1.3076.2.1.2.22.1.33 | Integer32 (-40..120) | read-only | current |
| alHardwareCageTempAlarm OBJECT-TYPE The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.34 | TruthValue | read-only | current |
| alHardwareCageTempCount OBJECT-TYPE The number of alarm events for the cage temperature. | 1.3.6.1.4.1.3076.2.1.2.22.1.35 | Counter32 | read-only | current |
| alHardwareCageTempTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for the cage temperature. | 1.3.6.1.4.1.3076.2.1.2.22.1.36 | TimeTicks | read-only | current |
| alHardwareFan1Rpm OBJECT-TYPE The current speed of fan 1 in RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.37 | Gauge32 | read-only | current |
| alHardwareFan1RpmAlarm OBJECT-TYPE The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.38 | TruthValue | read-only | current |
| alHardwareFan1RpmCount OBJECT-TYPE The number of alarm events for fan 1 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.39 | Counter32 | read-only | current |
| alHardwareFan1RpmTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for fan 1 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.40 | TimeTicks | read-only | current |
| alHardwareFan2Rpm OBJECT-TYPE The current speed of fan 2 in RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.41 | Gauge32 | read-only | current |
| alHardwareFan2RpmAlarm OBJECT-TYPE The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.42 | TruthValue | read-only | current |
| alHardwareFan2RpmCount OBJECT-TYPE The number of alarm events for fan 2 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.43 | Counter32 | read-only | current |
| alHardwareFan2RpmTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for fan 2 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.44 | TimeTicks | read-only | current |
| alHardwareFan3Rpm OBJECT-TYPE The current speed of fan 3 in RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.45 | Gauge32 | read-only | current |
| alHardwareFan3RpmAlarm OBJECT-TYPE The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range. | 1.3.6.1.4.1.3076.2.1.2.22.1.46 | TruthValue | read-only | current |
| alHardwareFan3RpmCount OBJECT-TYPE The number of alarm events for fan 3 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.47 | Counter32 | read-only | current |
| alHardwareFan3RpmTime OBJECT-TYPE The sysUptime at the time of the last change of alarm status for fan 3 RPM. | 1.3.6.1.4.1.3076.2.1.2.22.1.48 | TimeTicks | read-only | current |
| alHardwarePs1Type OBJECT-TYPE The type of power supply for Power Supply slot 1. | 1.3.6.1.4.1.3076.2.1.2.22.1.49 | INTEGER {none(1), ac(2)} | read-only | current |
| alHardwarePs2Type OBJECT-TYPE The type of power supply for Power Supply slot 2. | 1.3.6.1.4.1.3076.2.1.2.22.1.50 | INTEGER {none(1), ac(2)} | read-only | current |
| alHardwareSlot1Card OBJECT-TYPE The type of card in slot 1. | 1.3.6.1.4.1.3076.2.1.2.22.1.51 | ConcentratorCard | read-only | current |
| alHardwareSlot2Card OBJECT-TYPE The type of card in slot 2. | 1.3.6.1.4.1.3076.2.1.2.22.1.52 | ConcentratorCard | read-only | current |
| alHardwareSlot3Card OBJECT-TYPE The type of card in slot 3. | 1.3.6.1.4.1.3076.2.1.2.22.1.53 | ConcentratorCard | read-only | current |
| alHardwareSlot4Card OBJECT-TYPE The type of card in slot 4. | 1.3.6.1.4.1.3076.2.1.2.22.1.54 | ConcentratorCard | read-only | current |
| alHardwareSlot1Operational OBJECT-TYPE The operational status of card in slot 1. | 1.3.6.1.4.1.3076.2.1.2.22.1.55 | TruthValue | read-only | current |
| alHardwareSlot2Operational OBJECT-TYPE The operational status of card in slot 2. | 1.3.6.1.4.1.3076.2.1.2.22.1.56 | TruthValue | read-only | current |
| alHardwareSlot3Operational OBJECT-TYPE The operational status of card in slot 3. | 1.3.6.1.4.1.3076.2.1.2.22.1.57 | TruthValue | read-only | current |
| alHardwareSlot4Operational OBJECT-TYPE The operational status of card in slot 4. | 1.3.6.1.4.1.3076.2.1.2.22.1.58 | TruthValue | read-only | current |
| alHardwareRamSize OBJECT-TYPE The amount of memory, in MB on the concentrator. | 1.3.6.1.4.1.3076.2.1.2.22.1.59 | Unsigned32 | read-only | current |
| alHardwareChassis OBJECT-TYPE The type of VPN Concentrator this is. | 1.3.6.1.4.1.3076.2.1.2.22.1.60 | ConcentratorType | read-only | current |
| alHardwareCpuVoltageNominal OBJECT-TYPE The nominal CPU voltage in centivolts for the concentrator. | 1.3.6.1.4.1.3076.2.1.2.22.1.61 | Gauge32 | read-only | current |
| alHardwareClientEthPrivSwitch OBJECT-TYPE Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface. | 1.3.6.1.4.1.3076.2.1.2.22.1.62 | TruthValue | read-only | current |
| alHardwareSerialNumber OBJECT-TYPE Unit serial number. | 1.3.6.1.4.1.3076.2.1.2.22.1.63 | DisplayString | read-only | current |
Conformance
| Name | OID | Status |
|---|---|---|
| altigaHardwareStatsMibCompliance MODULE-COMPLIANCE The compliance statement for agents which implement the Altiga Hardware Statistics MIB. | 1.3.6.1.4.1.3076.1.1.27.2.1.1.1 | current |
| altigaHardwareStatsGroup OBJECT-GROUP The objects for Hardware statistics. | 1.3.6.1.4.1.3076.2.1.1.1.22.2 | current |