ALPHA-CONVERTER-SYS-MIB
- Registered at
- 1.3.6.1.4.1.7309.5.3.2
- Last updated
- 2015-07-28 00:00
- Organization
- Alpha Technologies Ltd.
- Revisions
- 2015-07-28 00:00, 2015-07-23 00:00, 2015-06-23 00:00
- Namespace
- alpha
- Source file
ALPHA-CONVERTER-SYS-MIB- Digest
sha256:a0c43d9ae98987c42a39810e79bf29b3aff903ae3bf89c2455da60a8730f9428
Description
This MIB defines the notification block(s) available in system controllers.
Contact
Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC V5J 5M4 Canada Tel: 1-604-436-5900 Fax: 1-604-436-1233
Imports
| From | Symbols |
|---|---|
| ALPHA-RESOURCE-MIB | ScaledNumber, simple |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ALPHA-CONVERTER-SYS-MIB ALPHA-RESOURCE-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| convSysTotalOutputCurrent OBJECT-TYPE Total converter output current in AMPS. | 1.3.6.1.4.1.7309.5.3.2.1 | ScaledNumber | read-only | current |
| convSysTotalOutputPower OBJECT-TYPE Total converter output power in WATTS. | 1.3.6.1.4.1.7309.5.3.2.2 | ScaledNumber | read-only | current |
| convSysTotalCapacityInstalledAmps OBJECT-TYPE A converter output current multiplied by the number of converters installed. | 1.3.6.1.4.1.7309.5.3.2.3 | ScaledNumber | read-only | current |
| convSysTotalCapacityInstalledPower OBJECT-TYPE A converter output power multiplied by the number of converters installed. | 1.3.6.1.4.1.7309.5.3.2.4 | ScaledNumber | read-only | current |
| convSysAverageConverterOutputVoltage OBJECT-TYPE Average converter output voltage. | 1.3.6.1.4.1.7309.5.3.2.5 | ScaledNumber | read-only | current |
| convSysAverageConverterInputVoltage OBJECT-TYPE Average input voltage supplied to the converters. | 1.3.6.1.4.1.7309.5.3.2.6 | ScaledNumber | read-only | current |
| convSysSystemVoltage OBJECT-TYPE System voltage. | 1.3.6.1.4.1.7309.5.3.2.7 | ScaledNumber | read-only | current |
| convSysTotalLoadCurrent OBJECT-TYPE Total load current. | 1.3.6.1.4.1.7309.5.3.2.8 | ScaledNumber | read-only | current |
| convSysSystemNumber OBJECT-TYPE Snmp ID# assigned to the system. | 1.3.6.1.4.1.7309.5.3.2.9 | ScaledNumber | read-only | current |
| conformance OBJECT-IDENTITY | 1.3.6.1.4.1.7309.5.3.2.100 | |||
| compliances OBJECT-IDENTITY | 1.3.6.1.4.1.7309.5.3.2.100.1 | |||
| converterGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7309.5.3.2.100.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| compliance MODULE-COMPLIANCE The compliance statement for systems supporting the Alpha Converter System MIB. | 1.3.6.1.4.1.7309.5.3.2.100.1.1 | current |
| converterGroup OBJECT-GROUP Alpha converter System data list group. | 1.3.6.1.4.1.7309.5.3.2.100.2.1 | current |