MIBs Depot

AGENT-GENERAL-MIB

Registered at
1.3.6.1.4.1.171.12.1
Last updated
2012-06-26 00:00
Organization
D-Link Corp.
Namespace
dlink
Source file
AGENT-GENERAL-MIB
Digest
sha256:91f939ea1d1b75ecffafaf29fb200c35489a4351f7df71ee2c1bd905e713d53a

Description

The structure of general management information for enterprise.

Contact

http://support.dlink.com

Imports

FromSymbols
DLINK-ID-REC-MIBAgentNotifyLevel, dlink-common-mgmt
INET-ADDRESS-MIBInetAddress, InetAddressType
Q-BRIDGE-MIBVlanId
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

AGENT-GENERAL-MIB
BRIDGE-MIB
DLINK-ID-REC-MIB
IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
P-BRIDGE-MIB
Q-BRIDGE-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB

Textual conventions

NameOIDSyntaxAccessStatus
Ipv6Address
TEXTUAL-CONVENTION
This data type is used to model IPv6 addresses. This is a binary string of 16 octets in network byte-order.
current
UnitList
type

Objects

NameOIDSyntaxAccessStatus
agentBasicInfo
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.1
agentMgmtProtocolCapability
OBJECT-TYPE
The network management protocol(s) supported by this agent.
1.3.6.1.4.1.171.12.1.1.1INTEGER {other(1), snmp-ip(2), snmp-ipx(3), snmp-ip-ipx(4)}read-onlycurrent
agentMibCapabilityTable
OBJECT-TYPE
A list of MIB capability entries supported by this agent.
1.3.6.1.4.1.171.12.1.1.2not-accessiblecurrent
agentMibCapabilityEntry
OBJECT-TYPE
A MIB capability entry containing objects that describe a particular MIB supported by this agent.
1.3.6.1.4.1.171.12.1.1.2.1not-accessiblecurrent
agentMibCapabilityIndex
OBJECT-TYPE
A list of Agent MIB Capability Description entries.
1.3.6.1.4.1.171.12.1.1.2.1.1Integer32read-onlycurrent
agentMibCapabilityDescr
OBJECT-TYPE
The name of the MIB supported by the agent.
1.3.6.1.4.1.171.12.1.1.2.1.2DisplayString (SIZE(0..35))read-onlycurrent
agentMibCapabilityVersion
OBJECT-TYPE
The version of the MIB specified in this entry.
1.3.6.1.4.1.171.12.1.1.2.1.3Integer32read-onlycurrent
agentMibCapabilityType
OBJECT-TYPE
The type of MIB specified in this entry.
1.3.6.1.4.1.171.12.1.1.2.1.4INTEGER {other(1), standard(2), proprietary(3), experiment(4)}read-onlycurrent
agentStatusConsoleInUse
OBJECT-TYPE
This indicates whether the console is currently in use.
1.3.6.1.4.1.171.12.1.1.3INTEGER {other(1), in-use(2), not-in-use(3)}read-onlycurrent
agentStatusSaveCfg
OBJECT-TYPE
This indicates the status of the device configuration. other (1) - This entry is currently in use but the conditions under which it will remain so are determined by each of the following values. proceeding (2) - The device configuration is currently being saved into NV-RAM. completed (3) - All of the device configuration parameters have been saved into NV-RAM. failed (4) - The process to save the device configuration has failed.
1.3.6.1.4.1.171.12.1.1.4INTEGER {other(1), proceeding(2), completed(3), failed(4)}read-onlycurrent
agentStatusFileTransfer
OBJECT-TYPE
The status of the firmware download control. If the value is stated as 'other', the firmware has not been updated since the device was started.
1.3.6.1.4.1.171.12.1.1.5INTEGER {other(1), in-process(2), invalid-file(3), violation(4), file-not-found(5), disk-full(6), complete(7), time-out(8), not-format(9), memory-full(10)}read-onlycurrent
agentCPUutilization
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.1.6
agentCPUutilizationIn5sec
OBJECT-TYPE
The time scale is set at 5 second intervals. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.12.1.1.6.1Integer32read-onlycurrent
agentCPUutilizationIn1min
OBJECT-TYPE
The time scale is set at 1 minute intervals. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.12.1.1.6.2Integer32read-onlycurrent
agentCPUutilizationIn5min
OBJECT-TYPE
The time scale is set at 5 minute intervals. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.12.1.1.6.3Integer32read-onlycurrent
agentDualImageStatus
OBJECT-TYPE
The dual image status.
1.3.6.1.4.1.171.12.1.1.7INTEGER {not-supported(0), supported(1)}read-onlycurrent
agentPORTutilizationTable
OBJECT-TYPE
This table specifies the current utilization of a specified port.
1.3.6.1.4.1.171.12.1.1.8not-accessiblecurrent
agentPORTutilizationEntry
OBJECT-TYPE
A list of information regarding the port utilization function.
1.3.6.1.4.1.171.12.1.1.8.1not-accessiblecurrent
agentPORTutilizationProtIndex
OBJECT-TYPE
This object indicates the module's port number.
1.3.6.1.4.1.171.12.1.1.8.1.1INTEGER (1..65535)read-onlycurrent
agentPORTutilizationTX
OBJECT-TYPE
The current rate of transmitted frames on the specified port.
1.3.6.1.4.1.171.12.1.1.8.1.2INTEGERread-onlycurrent
agentPORTutilizationRX
OBJECT-TYPE
The current rate of received frames on the specified port.
1.3.6.1.4.1.171.12.1.1.8.1.3INTEGERread-onlycurrent
agentPORTutilizationUtil
OBJECT-TYPE
The current percentages regarding port statistics.
1.3.6.1.4.1.171.12.1.1.8.1.4INTEGER (0..100)read-onlycurrent
agentPORTutilizationRXUtil
OBJECT-TYPE
The current percentages regarding port receive packets statistics.
1.3.6.1.4.1.171.12.1.1.8.1.5INTEGER (0..100)read-onlycurrent
agentPORTutilizationTXUtil
OBJECT-TYPE
The current percentages regarding port transmit packets statistics.
1.3.6.1.4.1.171.12.1.1.8.1.6INTEGER (0..100)read-onlycurrent
agentDRAMutilizationTable
OBJECT-TYPE
Information about DRAM memory.
1.3.6.1.4.1.171.12.1.1.9not-accessiblecurrent
agentDRAMutilizationEntry
OBJECT-TYPE
A list of information about DRAM memory.
1.3.6.1.4.1.171.12.1.1.9.1not-accessiblecurrent
agentDRAMutilizationUnitID
OBJECT-TYPE
Specifies the unit ID. If the ID equals zero, it means the current device.
1.3.6.1.4.1.171.12.1.1.9.1.1INTEGERread-onlycurrent
agentDRAMutilizationTotalDRAM
OBJECT-TYPE
The size of total DRAM memory.
1.3.6.1.4.1.171.12.1.1.9.1.2INTEGERread-onlycurrent
agentDRAMutilizationUsedDRAM
OBJECT-TYPE
The size of used DRAM memory.
1.3.6.1.4.1.171.12.1.1.9.1.3INTEGERread-onlycurrent
agentDRAMutilization
OBJECT-TYPE
The percentage of used DRAM memory of the total DRAM memory available. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.12.1.1.9.1.4INTEGERread-onlycurrent
agentFLASHutilizationTable
OBJECT-TYPE
Information about the flash memory.
1.3.6.1.4.1.171.12.1.1.10not-accessiblecurrent
agentFLASHutilizationEntry
OBJECT-TYPE
Information about the flash memory.
1.3.6.1.4.1.171.12.1.1.10.1not-accessiblecurrent
agentFLASHutilizationUnitID
OBJECT-TYPE
Specifies the unit ID. If the ID equals zero, it means the current device.
1.3.6.1.4.1.171.12.1.1.10.1.1INTEGERread-onlycurrent
agentFLASHutilizationTotalFLASH
OBJECT-TYPE
The total size of flash memory.
1.3.6.1.4.1.171.12.1.1.10.1.2INTEGERread-onlycurrent
agentFLASHutilizationUsedFLASH
OBJECT-TYPE
The size of the used flash memory.
1.3.6.1.4.1.171.12.1.1.10.1.3INTEGERread-onlycurrent
agentFLASHutilization
OBJECT-TYPE
The percentage of used flash memory in total flash memory. The value will be between 0% (idle) and 100% (very busy).
1.3.6.1.4.1.171.12.1.1.10.1.4INTEGERread-onlycurrent
agentStatusReset
OBJECT-TYPE
This indicates the status of 'agentReset'.
1.3.6.1.4.1.171.12.1.1.11INTEGER {proceeding(1), completed(2), failed(3)}read-onlycurrent
agentSerialNumber
OBJECT-TYPE
A text string containing the serial number of this device.
1.3.6.1.4.1.171.12.1.1.12DisplayStringread-onlycurrent
agentFirmwareType
OBJECT-TYPE
A text string containing the firmware type.
1.3.6.1.4.1.171.12.1.1.13DisplayStringread-onlycurrent
agentBasicConfig
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2
agentBscSwFileTable
OBJECT-TYPE
A list of MIB Basic Config entry support files updated by this agent.
1.3.6.1.4.1.171.12.1.2.1not-accessiblecurrent
agentBscSwFileEntry
OBJECT-TYPE
A basic configuration entry containing the objects that describe a particular MIB supported by this agent.
1.3.6.1.4.1.171.12.1.2.1.1not-accessiblecurrent
agentBscSwFileIndex
OBJECT-TYPE
The table index for the file entry
1.3.6.1.4.1.171.12.1.2.1.1.1Integer32read-onlycurrent
agentBscSwFileDscr
OBJECT-TYPE
The description of the software file purpose in this entry. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.1.1.2DisplayString (SIZE(0..64))read-writecurrent
agentBscSwFileAddr
OBJECT-TYPE
The IP address where the file that needs to be downloaded is located, or the IP address where the file will be uploaded to.
1.3.6.1.4.1.171.12.1.2.1.1.3IpAddressread-writecurrent
agentBscSwFileTransferType
OBJECT-TYPE
The channel through which the file will be downloaded or uploaded. Note: For systems that do not support all channels, setting a value to the unsupported channel will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.1.1.4INTEGER {other(1), network-load(2), out-of-band-load(3)}read-writecurrent
agentBscSwFile
OBJECT-TYPE
The name of the file to be downloaded from, or uploaded to, the TFTP server.
1.3.6.1.4.1.171.12.1.2.1.1.5DisplayString (SIZE(0..128))read-writecurrent
agentBscSwFileLocateId
OBJECT-TYPE
This object describes the type of file. runtime-code (1), log-file (2), cfg-file (3) Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.1.1.6INTEGER (1..16)read-writecurrent
agentBscSwFileLoadType
OBJECT-TYPE
This object provides the user with a choice of uploading or downloading the selected file. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.1.1.7INTEGER {other(1), upload(2), download(3)}read-writecurrent
agentBscSwFileCtrl
OBJECT-TYPE
This object gives the user the option of downloading runtime software. This setting will take effect when the system restarts. See Note (1) below Note: For systems that do not support changes to this object, setting a value to this object will cause the system to return bad-value error messages. start - Activate firmware. delete (4) - Delete the firmware by indicated firmware ID. config-as-bootup (5) - Configured as bootup firmware by the indicated firmware(ID). apply (6) - Apply the configuration to be the active configuration by the indicated config ID.
1.3.6.1.4.1.171.12.1.2.1.1.8INTEGER {other(1), inactive(2), start(3), delete(4), config-as-bootup(5), apply(6)}read-writecurrent
agentBscSwFileBIncrement
OBJECT-TYPE
This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase.
1.3.6.1.4.1.171.12.1.2.1.1.9TruthValueread-writecurrent
agentBscSwFileCtrlID
OBJECT-TYPE
The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file.
1.3.6.1.4.1.171.12.1.2.1.1.10INTEGERread-writecurrent
agentBscSwFileCtrlUnitID
OBJECT-TYPE
Specifies which unit of the switch stack the firmware image will be downloaded from. One or more units can be set in this list. Each bit from the left to the right represents the switch from unit ID 1 to unit ID 12. A null entry in this field denotes all switches in the switch stack.
1.3.6.1.4.1.171.12.1.2.1.1.11UnitListread-writecurrent
agentBscSwFileIPv6Addr
OBJECT-TYPE
The IPv6 address where the file will be downloaded from or uploaded to.
1.3.6.1.4.1.171.12.1.2.1.1.12Ipv6Addressread-writecurrent
agentBscSwFileBootUpImage
OBJECT-TYPE
The result of the download will depend on whether the boot_up option is specified. Case 1: In the case where the master unit provides the file system and the slave unit does not provide the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case where the master unit does not provide the file system and the slave unit provides the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, the file will not be downloaded to this slave unit. Case 3: In the case where the master unit and the slave unit both support or do not support the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified.
1.3.6.1.4.1.171.12.1.2.1.1.13TruthValueread-writecurrent
agentBscSwFileForceAgree
OBJECT-TYPE
When the force_agree option is specified, the reboot command will be executed immediately, without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified.
1.3.6.1.4.1.171.12.1.2.1.1.14TruthValueread-writecurrent
agentBscSwFileInterfaceName
OBJECT-TYPE
This node is used to specify the interface name when the agentBscSwFileIPv6Addr is the link local address.
1.3.6.1.4.1.171.12.1.2.1.1.15DisplayString (SIZE(0..12))read-writecurrent
agentBscSwFileServerDomainName
OBJECT-TYPE
This object indicates the domain name of the TFTP server.
1.3.6.1.4.1.171.12.1.2.1.1.16DisplayString (SIZE(0..255))read-writecurrent
agentFileTransfer
OBJECT-TYPE
This object will execute the download or upload action. If start (2) is chosen, it will begin to download/upload and no reset will follow. If start-and-reset (3) is chosen, then the reset will be activated after completing the download or upload. No action if noaction (4) is chosen. Note: Because these functions will be limited by the support for the system in question, some of the selected items will be invalid. When the user selects an invalid entry, the system will respond with a bad-value status.
1.3.6.1.4.1.171.12.1.2.2INTEGER {other(1), start(2), start-and-reset(3), noaction(4)}read-writeobsolete
agentSystemReset
OBJECT-TYPE
This object indicates the agent system reset state. Setting this object to no-reset (4) has no effect. Setting this object to cold-start (2) or warm-start (3) will reset the agent. The agent always returns to no-reset (4) when this object is read. This object is replaced by 'agentReset'.
1.3.6.1.4.1.171.12.1.2.3INTEGER {other(1), cold-start(2), warm-start(3), no-reset(4)}read-writedeprecated
agentRs232PortConfig
OBJECT-TYPE
This object indicates the RS-232C mode once the device has restarted.
1.3.6.1.4.1.171.12.1.2.4INTEGER {other(1), console(2), out-of-band(3), notAvail(4)}read-writecurrent
agentOutOfBandBaudRateConfig
OBJECT-TYPE
This object allows the user to specify an out-of-band baud rate, which will take effect upon system restart. Note: Because these functions will be limited by the support for the system in question, some of the selected items will be invalid. When the user selects an invalid entry, the system will respond with a bad-value error message.
1.3.6.1.4.1.171.12.1.2.5INTEGER {other(1), baudRate-2400(2), baudRate-9600(3), baudRate-19200(4), baudRate-38400(5), baudRate-115200(6)}read-writeobsolete
agentSaveCfg
OBJECT-TYPE
This object indicates the type of save command to be executed, when saving to NV-RAM. other (1) - None of the following. cfg-id1 (2) - Save configuration ID1. cfg-id2 (3)- Save configuration ID2. log (4) - Save log. all (5) - Save both (active configuration and log).
1.3.6.1.4.1.171.12.1.2.6INTEGER {other(1), cfg-id1(2), cfg-id2(3), log(4), all(5)}read-writecurrent
swMultiImageInfoTable
OBJECT-TYPE
1.3.6.1.4.1.171.12.1.2.7not-accessiblecurrent
swMultiImageInfoEntry
OBJECT-TYPE
A list of information about multiple image management.
1.3.6.1.4.1.171.12.1.2.7.1not-accessiblecurrent
swMultiImageInfoID
OBJECT-TYPE
The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID.
1.3.6.1.4.1.171.12.1.2.7.1.1INTEGERread-onlycurrent
swMultiImageVersion
OBJECT-TYPE
The recorded downloaded firmware version.
1.3.6.1.4.1.171.12.1.2.7.1.2DisplayString (SIZE(0..32))read-onlycurrent
swMultiImageSize
OBJECT-TYPE
The recorded downloaded firmware size.
1.3.6.1.4.1.171.12.1.2.7.1.3Integer32read-onlycurrent
swMultiImageUpdateTime
OBJECT-TYPE
The recorded firmware update time.
1.3.6.1.4.1.171.12.1.2.7.1.4DisplayString (SIZE(0..32))read-onlycurrent
swMultiImageFrom
OBJECT-TYPE
The recorded IP address of the TFTP server
1.3.6.1.4.1.171.12.1.2.7.1.5DisplayString (SIZE(0..100))read-onlycurrent
swMultiImageSendUser
OBJECT-TYPE
The record of the user who downloaded the firmware.
1.3.6.1.4.1.171.12.1.2.7.1.6DisplayString (SIZE(0..32))read-onlycurrent
swMultiImageFileName
OBJECT-TYPE
When the system is set to boot from SD card, this object will display the recorded path name of the boot firmware file.
1.3.6.1.4.1.171.12.1.2.7.1.7DisplayString (SIZE(0..255))read-onlycurrent
agentMultiCfgMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.8
swMultiCfgInfoTable
OBJECT-TYPE
1.3.6.1.4.1.171.12.1.2.8.1not-accessiblecurrent
swMultiCfgInfoEntry
OBJECT-TYPE
A list of information about multiple configuration files.
1.3.6.1.4.1.171.12.1.2.8.1.1not-accessiblecurrent
swMultiCfgInfoID
OBJECT-TYPE
The section ID of the configuration files.
1.3.6.1.4.1.171.12.1.2.8.1.1.1INTEGERread-onlycurrent
swMultiCfgVersion
OBJECT-TYPE
The recorded downloaded configuration version.
1.3.6.1.4.1.171.12.1.2.8.1.1.2DisplayString (SIZE(0..32))read-onlycurrent
swMultiCfgSize
OBJECT-TYPE
The recorded downloaded configuration size (in bytes).
1.3.6.1.4.1.171.12.1.2.8.1.1.3Integer32read-onlycurrent
swMultiCFgUpdateTime
OBJECT-TYPE
The recorded configuration update time displayed in string format, i.e. yyyy/mon/dd hh:mm:ss.
1.3.6.1.4.1.171.12.1.2.8.1.1.4DisplayString (SIZE(0..32))read-onlycurrent
swMultiCfgFrom
OBJECT-TYPE
The recorded IP address of the TFTP server.
1.3.6.1.4.1.171.12.1.2.8.1.1.5DisplayString (SIZE(0..100))read-onlycurrent
swMultiCfgSendUser
OBJECT-TYPE
The record of the user who downloaded the configuration file
1.3.6.1.4.1.171.12.1.2.8.1.1.6DisplayString (SIZE(0..32))read-onlycurrent
swMultiCfgFileName
OBJECT-TYPE
When the system is set to boot from SD card, this object displays the recorded path name of the boot configuration file.
1.3.6.1.4.1.171.12.1.2.8.1.1.7DisplayString (SIZE(0..255))read-onlycurrent
swMultiCfgCurrentUsed
OBJECT-TYPE
The indicated configuration file ID of the system currently in use.
1.3.6.1.4.1.171.12.1.2.8.2INTEGERread-onlycurrent
swMultiCfgBootUp
OBJECT-TYPE
This object indicates the configuration file ID which will take effect upon the next reboot.
1.3.6.1.4.1.171.12.1.2.8.3INTEGERread-onlycurrent
swMultiCfgCtrlTable
OBJECT-TYPE
1.3.6.1.4.1.171.12.1.2.8.4not-accessiblecurrent
swMultiCfgCtrlEntry
OBJECT-TYPE
A list of information about multiple configuration management.
1.3.6.1.4.1.171.12.1.2.8.4.1not-accessiblecurrent
swMultiCfgCtrlID
OBJECT-TYPE
The section ID of the configuration file.
1.3.6.1.4.1.171.12.1.2.8.4.1.1INTEGER {cfgId-1(1), cfgId-2(2)}read-onlycurrent
swMultiCfgAction
OBJECT-TYPE
save: Save configuration to active configuration ID when the parameter is omitted. active: Set any valid configuration as the active configuration. delete: Removes the configuration from the flash memory. This configuration cannot be the active or current configuration file. apply: Loads the indicated configuration file and applies it to the system. config-as-bootup-cfg: Configured as the boot-up configuration by the indicated configuration(ID).
1.3.6.1.4.1.171.12.1.2.8.4.1.2INTEGER {active(1), delete(2), apply(3), none(4), config-as-bootup-cfg(5)}read-writecurrent
systemSeverityControlMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.9
systemSeverityTrapControl
OBJECT-TYPE
Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur.
1.3.6.1.4.1.171.12.1.2.9.1AgentNotifyLevelread-writecurrent
systemSeverityLogControl
OBJECT-TYPE
Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur.
1.3.6.1.4.1.171.12.1.2.9.2AgentNotifyLevelread-writecurrent
agentTrustedHostMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.10
agentTrustedHostTable
OBJECT-TYPE
This table contains the trusted host information.
1.3.6.1.4.1.171.12.1.2.10.1not-accessiblecurrent
agentTrustedHostEntry
OBJECT-TYPE
A list of information about the trusted hosts.
1.3.6.1.4.1.171.12.1.2.10.1.1not-accessiblecurrent
agentTrustedHostIndex
OBJECT-TYPE
The index of the trusted host entry.
1.3.6.1.4.1.171.12.1.2.10.1.1.1INTEGER (1..30)read-onlycurrent
agentTrustedHostIPAddress
OBJECT-TYPE
Specifies the IP address of the trusted host.
1.3.6.1.4.1.171.12.1.2.10.1.1.2IpAddressread-createcurrent
agentTrustedHostRowStatus
OBJECT-TYPE
Indicates the status of this entry. When creating a trusted host entry, the IP address should also be set.
1.3.6.1.4.1.171.12.1.2.10.1.1.3RowStatusread-createcurrent
agentTrustedHostIPSubnetMask
OBJECT-TYPE
Specifies the IP subnet mask of the trusted host.
1.3.6.1.4.1.171.12.1.2.10.1.1.4IpAddressread-createcurrent
agentTrustedHostForSNMP
OBJECT-TYPE
Specifies the trusted host for SNMP.
1.3.6.1.4.1.171.12.1.2.10.1.1.5INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostForTELNET
OBJECT-TYPE
Specifies the trusted host for Telnet.
1.3.6.1.4.1.171.12.1.2.10.1.1.6INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostForSSH
OBJECT-TYPE
Specifies the trusted host for SSH.
1.3.6.1.4.1.171.12.1.2.10.1.1.7INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostForHTTP
OBJECT-TYPE
Specifies the trusted host for HTTP.
1.3.6.1.4.1.171.12.1.2.10.1.1.8INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostForHTTPS
OBJECT-TYPE
Specifies the trusted host for HTTPS.
1.3.6.1.4.1.171.12.1.2.10.1.1.9INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostForPING
OBJECT-TYPE
Specifies the trusted host for PING.
1.3.6.1.4.1.171.12.1.2.10.1.1.10INTEGER {enabled(1), disabled(2)}read-createcurrent
agentTrustedHostAddrType
OBJECT-TYPE
The type of trusted host address as specified by the 'agentTrustedHostAddr' object.
1.3.6.1.4.1.171.12.1.2.10.1.1.11InetAddressTyperead-createcurrent
agentTrustedHostAddr
OBJECT-TYPE
Specifies the IP address of the trusted host.
1.3.6.1.4.1.171.12.1.2.10.1.1.12InetAddressread-createcurrent
agentTrustedHostIPv6PrefixLen
OBJECT-TYPE
Specifies the IPv6 prefix length of the IPv6 trusted host.
1.3.6.1.4.1.171.12.1.2.10.1.1.13INTEGER (1..128)read-createcurrent
agentTrustedHostDelAllState
OBJECT-TYPE
Used to delete all trusted host entries.
1.3.6.1.4.1.171.12.1.2.10.2INTEGER {none(1), start(2)}read-writecurrent
agentFDBMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.11
agentFDBClearAllState
OBJECT-TYPE
Used to clear all FDB entries.
1.3.6.1.4.1.171.12.1.2.11.1INTEGER {other(1), start(2)}read-writecurrent
agentFDBClearByPortTable
OBJECT-TYPE
Used to clear FDB entries by port.
1.3.6.1.4.1.171.12.1.2.11.2not-accessiblecurrent
agentFDBClearByPortEntry
OBJECT-TYPE
This is an entry of the agentFDBClearByPortTable.
1.3.6.1.4.1.171.12.1.2.11.2.1not-accessiblecurrent
agentFDBClearPortIndex
OBJECT-TYPE
This object indicates the port number.
1.3.6.1.4.1.171.12.1.2.11.2.1.1INTEGER (1..65535)not-accessiblecurrent
agentFDBClearByPortAction
OBJECT-TYPE
This object indicates whether to clear FDB or not.
1.3.6.1.4.1.171.12.1.2.11.2.1.2INTEGER {other(1), start(2)}read-writecurrent
agentFDBClearByVlanTable
OBJECT-TYPE
Used to clear FDB entries by port.
1.3.6.1.4.1.171.12.1.2.11.3not-accessiblecurrent
agentFDBClearByVlanEntry
OBJECT-TYPE
This is an entry of agentFDBClearByPortTable.
1.3.6.1.4.1.171.12.1.2.11.3.1not-accessiblecurrent
agentFDBClearVid
OBJECT-TYPE
This object indicates the VLAN-ID.
1.3.6.1.4.1.171.12.1.2.11.3.1.1VlanIdnot-accessiblecurrent
agentFDBClearByVlanAction
OBJECT-TYPE
This object indicates whether to clear the FDB or not.
1.3.6.1.4.1.171.12.1.2.11.3.1.2INTEGER {other(1), start(2)}read-writecurrent
agentFDBSecurityTable
OBJECT-TYPE
Used to display the FDB entries that have been created by the security module.
1.3.6.1.4.1.171.12.1.2.11.4not-accessiblecurrent
agentFDBSecurityEntry
OBJECT-TYPE
This is an entry of agentFDBSecurityTable.
1.3.6.1.4.1.171.12.1.2.11.4.1not-accessiblecurrent
agentFDBVid
OBJECT-TYPE
This object indicates the VLAN-ID.
1.3.6.1.4.1.171.12.1.2.11.4.1.1VlanIdnot-accessiblecurrent
agentFDBMacAddress
OBJECT-TYPE
This object indicates the MAC address.
1.3.6.1.4.1.171.12.1.2.11.4.1.2MacAddressnot-accessiblecurrent
agentFDBPort
OBJECT-TYPE
This object indicates the port number.
1.3.6.1.4.1.171.12.1.2.11.4.1.3INTEGER (1..65535)read-onlycurrent
agentFDBType
OBJECT-TYPE
This object indicates the MAC address type.
1.3.6.1.4.1.171.12.1.2.11.4.1.4INTEGER {dynamic(1), static(2)}read-onlycurrent
agentFDBStatus
OBJECT-TYPE
This object indicates the MAC address's forwarding status.
1.3.6.1.4.1.171.12.1.2.11.4.1.5INTEGER {drop(1), forward(2)}read-onlycurrent
agentFDBSecurityModule
OBJECT-TYPE
This object is used to indicate which security module created the current MAC address. dot1x: 802.1X. wac: Web-based Access Control. jwac: Web-Based Access Control extension for Japan. port-security: Port Security. mac-based-access-control: MAC-based Access Control. compound-authentication: Compound Authentication.
1.3.6.1.4.1.171.12.1.2.11.4.1.6INTEGER {dot1x(1), wac(2), jwac(3), port-security(4), mac-based-access-control(5), compound-authentication(6)}read-onlycurrent
agentARPMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.12
agentARPClearAllState
OBJECT-TYPE
Used to clear all ARP entries.
1.3.6.1.4.1.171.12.1.2.12.1INTEGER {other(1), start(2)}read-writecurrent
agentGratuitousARPMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.12.2
agentGratuitousARPSendIpifStatusUpState
OBJECT-TYPE
This is used to enable/disable sending of gratuitous ARP request packets while the IPIF interface comes up. This is used to automatically announce the interface's IP address to other nodes. By default, the state is enabled, and only one ARP packet will be broadcast.
1.3.6.1.4.1.171.12.1.2.12.2.1INTEGER {enabled(1), disabled(2)}read-writecurrent
agentGratuitousARPSendDupIpDetectedState
OBJECT-TYPE
This is used to enable/disable the sending of gratuitous ARP request packets while a duplicate IP is detected. By default, the state is enabled. The duplicate IP detected state indicates that the system has received an ARP request packet that was sent by an IP address that matches the system's own IP address. In this case, the system knows that somebody out there is using an IP address that is in conflict with the system. In order to reclaim the correct host of this IP address, the system can send out the gratuitous ARP request packet for this duplicate IP address.
1.3.6.1.4.1.171.12.1.2.12.2.2INTEGER {enabled(1), disabled(2)}read-writecurrent
agentGratuitousARPLearningState
OBJECT-TYPE
This is used to enable/disable learning of an ARP entry in the ARP cache based on the received gratuitous ARP packet. If the switch receives a gratuitous ARP request/reply packet and the sender's IP address is in its ARP table, it should update the ARP entry. By default, the state is disabled.
1.3.6.1.4.1.171.12.1.2.12.2.3INTEGER {enabled(1), disabled(2)}read-writecurrent
agentGratuitousARPTable
OBJECT-TYPE
Gratuitous ARP Table Information.
1.3.6.1.4.1.171.12.1.2.12.2.4not-accessiblecurrent
agentGratuitousARPEntry
OBJECT-TYPE
A list of information from the Gratuitous ARP Table.
1.3.6.1.4.1.171.12.1.2.12.2.4.1not-accessiblecurrent
agentGratuitousARPInterfaceName
OBJECT-TYPE
The name of the IP interface.
1.3.6.1.4.1.171.12.1.2.12.2.4.1.1DisplayStringread-onlycurrent
agentGratuitousARPPeriodicalSendInterval
OBJECT-TYPE
This is used to configure the interval for the periodic sending of gratuitous ARP request packets. 0 means do not send gratuitous ARP request packets periodically.
1.3.6.1.4.1.171.12.1.2.12.2.4.1.2INTEGER (0..65535)read-writecurrent
agentGratuitousARPTrapState
OBJECT-TYPE
This indicates the state of the gratuitous ARP trap. The switch can trap the IP conflict events to inform the administrator. By default, the trap is disabled.
1.3.6.1.4.1.171.12.1.2.12.2.4.1.3INTEGER {enabled(1), disabled(2)}read-writecurrent
agentGratuitousARPLogState
OBJECT-TYPE
This indicates the state of the gratuitous Log trap. The switch can log the IP conflict events to inform the administrator. By default, the event log is enabled.
1.3.6.1.4.1.171.12.1.2.12.2.4.1.4INTEGER {enabled(1), disabled(2)}read-writecurrent
agentARPTotalARPEntries
OBJECT-TYPE
Used to display the total number of ARP entries.
1.3.6.1.4.1.171.12.1.2.12.3INTEGERread-onlycurrent
agentARPRetryTimes
OBJECT-TYPE
This indicates the retry times of the ARP request.
1.3.6.1.4.1.171.12.1.2.12.4INTEGERread-writecurrent
swMultiImageCtrlTable
OBJECT-TYPE
1.3.6.1.4.1.171.12.1.2.13not-accessiblecurrent
swMultiImageCtrlEntry
OBJECT-TYPE
A list of information about multiple image management.
1.3.6.1.4.1.171.12.1.2.13.1not-accessiblecurrent
swMultiImageCtrlID
OBJECT-TYPE
The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID.
1.3.6.1.4.1.171.12.1.2.13.1.1INTEGERread-onlycurrent
swMultiImageCtrlAction
OBJECT-TYPE
This object indicates the running status of the image which is specified by swMultiImageCtrlID and swMultiImageCtrlUnitID. config-as-bootup-fw (1) - Configured as the bootup firmware by the indicated firmware(ID). delete (2) - Delete the firmware by indicated firmware ID. none (3) - No action.
1.3.6.1.4.1.171.12.1.2.13.1.2INTEGER {config-as-bootup-fw(1), delete(2), none(3)}read-writecurrent
agentOutOfBandDataBits
OBJECT-TYPE
This object indicates the out-of-band data bits.
1.3.6.1.4.1.171.12.1.2.14INTEGERread-onlycurrent
agentOutOfBandParityBits
OBJECT-TYPE
This object indicates the out-of-band parity bits.
1.3.6.1.4.1.171.12.1.2.15DisplayStringread-onlycurrent
agentOutOfBandStopBits
OBJECT-TYPE
This object indicates the out-of-band stop bits.
1.3.6.1.4.1.171.12.1.2.16INTEGERread-onlycurrent
agentOutOfBandAutoLogoutConfig
OBJECT-TYPE
This object allows the user to specify an out-of-band auto logout time.
1.3.6.1.4.1.171.12.1.2.17INTEGER {never(1), minutes-2(2), minutes-5(3), minutes-10(4), minutes-15(5)}read-writecurrent
agentBscFileSystemMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.18
agentBscFileSystemTable
OBJECT-TYPE
A list of MIB File System Basic Configuration entries supported by the file update of this agent.
1.3.6.1.4.1.171.12.1.2.18.1not-accessiblecurrent
agentBscFileSystemEntry
OBJECT-TYPE
A File System basic configuration entry that contains objects describing a particular MIB supported by this agent.
1.3.6.1.4.1.171.12.1.2.18.1.1not-accessiblecurrent
agentBscFileSystemIndex
OBJECT-TYPE
The table index for the file entry. This object describes the file type. runtime-code (1), log-file (2), cfg-file (3), attack-log-file (7)
1.3.6.1.4.1.171.12.1.2.18.1.1.1Integer32read-onlycurrent
agentBscFileSystemDscr
OBJECT-TYPE
The description of the software file purpose in this entry.
1.3.6.1.4.1.171.12.1.2.18.1.1.2DisplayString (SIZE(0..64))read-onlycurrent
agentBscFileSystemServerAddr
OBJECT-TYPE
The IP address where the file to be downloaded is located, or the IP address where the file will be uploaded to.
1.3.6.1.4.1.171.12.1.2.18.1.1.3IpAddressread-writecurrent
agentBscFileSystemServerIPv6Addr
OBJECT-TYPE
The IPv6 address where the file is to be downloaded from or uploaded to.
1.3.6.1.4.1.171.12.1.2.18.1.1.4Ipv6Addressread-writecurrent
agentBscFileSystemServerFileName
OBJECT-TYPE
The name of the file to be downloaded from or uploaded to the TFTP server. If agentBscFileSystemDeviceFileName is not set, the switch will default to using the bootup file as the runtime image for the switch.
1.3.6.1.4.1.171.12.1.2.18.1.1.5DisplayString (SIZE(0..64))read-writecurrent
agentBscFileSystemDeviceDriverID
OBJECT-TYPE
Specifies the drive of the device that the firmware to be uploaded/downloaded is located. If none (1) is specified, the switch will default to the current drive.
1.3.6.1.4.1.171.12.1.2.18.1.1.6INTEGER {none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27)}read-writecurrent
agentBscFileSystemDeviceFileName
OBJECT-TYPE
The name of the file to be downloaded to the device, or uploaded from the device. When downloading or uploading, the agentBscFileSystemServerFileName object must also be set.
1.3.6.1.4.1.171.12.1.2.18.1.1.7DisplayString (SIZE(0..64))read-writecurrent
agentBscFileSystemLoadType
OBJECT-TYPE
This object allows the user to select a download or upload function for the file. Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return a bad-value error message.
1.3.6.1.4.1.171.12.1.2.18.1.1.8INTEGER {other(1), upload(2), download(3)}read-writecurrent
agentBscFileSystemCtrlUnitID
OBJECT-TYPE
Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12. If this list is set to null it represents all stack switches.
1.3.6.1.4.1.171.12.1.2.18.1.1.9UnitListread-writecurrent
agentBscFileSystemBootUpImage
OBJECT-TYPE
The result of the download will depend on whether the boot_up option has been specified. Case 1: In the case of the master unit providing the file system and the slave unit not providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave. If the boot_up parameter is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case of the master unit not providing the file system and the slave unit providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 3: In the case of the master unit and the slave unit both supporting or not supporting the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified..
1.3.6.1.4.1.171.12.1.2.18.1.1.10TruthValueread-writecurrent
agentBscFileSystemForceAgree
OBJECT-TYPE
When the force_agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified..
1.3.6.1.4.1.171.12.1.2.18.1.1.11TruthValueread-writecurrent
agentBscFileSystemCtrl
OBJECT-TYPE
This object allows the user to download runtime software. The settings will take effect when the system restarts. See Note (1) below Note 1: For systems which do not support value changes to this object, setting these values will cause the system to return a bad-value error message start (3) - activate firmware.
1.3.6.1.4.1.171.12.1.2.18.1.1.12INTEGER {other(1), inactive(2), start(3)}read-writecurrent
agentBscFileSystemInterfaceName
OBJECT-TYPE
This node is used to specify the interface name when agentBscFileSystemServerIPv6Addr is the local link address.
1.3.6.1.4.1.171.12.1.2.18.1.1.13DisplayString (SIZE(0..12))read-writecurrent
agentBscFileSystemServerDomainName
OBJECT-TYPE
This object indicates the domain name of the TFTP server.
1.3.6.1.4.1.171.12.1.2.18.1.1.14DisplayString (SIZE(0..255))read-writecurrent
agentBscFileSystemIncrement
OBJECT-TYPE
If increment is specified, then the existing configuration will not be cleared before applying of the new configuration. If it is not specified, then the existing configuration will be cleared before applying of the new configuration. True : keep valid False : erase.
1.3.6.1.4.1.171.12.1.2.18.1.1.15TruthValueread-writecurrent
agentBscFileSystemServerVrfName
OBJECT-TYPE
This object indicates the VRF name of the TFTP server.Input string 'reserved' for the global space.
1.3.6.1.4.1.171.12.1.2.18.1.1.16DisplayString (SIZE(0..12))read-writecurrent
agentBscFileSystemSaveConfigDriverID
OBJECT-TYPE
The drive on the device that the configuration file is will be saved to. If none (1) is specified, the switch places the file on the current drive by default.
1.3.6.1.4.1.171.12.1.2.18.2INTEGER {none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27)}read-writecurrent
agentBscFileSystemSaveConfigFileName
OBJECT-TYPE
The name of the configuration file that will be saved to the device. When agentBscFileSystemSaveCfg is set to cfg (2), and if the agentBscFileSystemSaveConfigFileName is not null, the configuration file will be saved to the set file name. If set to null, the configuration file will be saved to the boot_up CFG file.
1.3.6.1.4.1.171.12.1.2.18.3DisplayString (SIZE(0..64))read-writecurrent
agentBscFileSystemSaveCfg
OBJECT-TYPE
This indicates the method of saving information to the NV-RAM of the device. other (1) - None of the following. cfg (2) - Save configuration. log (3) - Save log. all (4) - Save both ( active configuration and log).
1.3.6.1.4.1.171.12.1.2.18.4INTEGER {other(1), cfg(2), log(3), all(4)}read-writecurrent
agentFileSystemConfigTable
OBJECT-TYPE
This table indicates the information about the bootup files.
1.3.6.1.4.1.171.12.1.2.18.5not-accessiblecurrent
agentFileSystemConfigEntry
OBJECT-TYPE
A list of information about the bootup files for each unit of the switch stack.
1.3.6.1.4.1.171.12.1.2.18.5.1not-accessiblecurrent
agentFileSystemUnit
OBJECT-TYPE
The unit ID.
1.3.6.1.4.1.171.12.1.2.18.5.1.1Integer32read-onlycurrent
agentFileSystemDriverID
OBJECT-TYPE
The drive on the device that the configuration file will be saved to. If none (1) is specified, the switch will place the file to the current drive by default.
1.3.6.1.4.1.171.12.1.2.18.5.1.2INTEGER {none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27)}read-writecurrent
agentFileSystemBootImage
OBJECT-TYPE
When displayed, it shows the current bootup image file name. When set, the set name will be set as the bootup image.
1.3.6.1.4.1.171.12.1.2.18.5.1.3DisplayString (SIZE(0..64))read-writecurrent
agentFileSystemBootConfig
OBJECT-TYPE
When displayed, it shows the current bootup configuration file name. When set, the set name will be set as the bootup configuration.
1.3.6.1.4.1.171.12.1.2.18.5.1.4DisplayString (SIZE(0..64))read-writecurrent
agentFileSystemActConfig
OBJECT-TYPE
When displayed, it shows null. When set, the set name will be active at once, but the set name will not be set as the bootup configuration.
1.3.6.1.4.1.171.12.1.2.18.5.1.5DisplayString (SIZE(0..64))read-writecurrent
agentReboot
OBJECT-TYPE
Used to restart the switch.
1.3.6.1.4.1.171.12.1.2.19INTEGER {none(1), start(2)}read-writecurrent
agentReset
OBJECT-TYPE
Used to reset all switch parameters. none (1): No action. This is the default value of this object. config (2): All parameters are reset to default settings. The device will neither save nor reboot. system (3): All parameters are reset to default settings. The switch will then do a factory reset, save, and reboot. reset (4) : All parameters will be reset to default settings except for the IP address, user account, and history log. The device will neither save nor reboot. system-exclude-vlan(5) : All parameters are reset to default settings except for VLAN. The switch will then save its settings and reboot. system-exclude-ip(6) : All parameters are reset to default settings except IP address. The switch will then save its settings and reboot. system-exclude-vlan-ip(7): All parameters are reset to default settings except VLAN and IP address. The switch will then save its settings and reboot.
1.3.6.1.4.1.171.12.1.2.20INTEGER {none(1), config(2), system(3), reset(4), system-exclude-vlan(5), system-exclude-ip(6), system-exclude-vlan-ip(7)}read-writecurrent
agentFTPFileTable
OBJECT-TYPE
A list of the MIB Basic Config entries support files updated by this agent.
1.3.6.1.4.1.171.12.1.2.21not-accessiblecurrent
agentFTPFileEntry
OBJECT-TYPE
A basic configuration entry containing the objects describing a particular MIB supported by this agent.
1.3.6.1.4.1.171.12.1.2.21.1not-accessiblecurrent
agentFTPFileIndex
OBJECT-TYPE
The table index for the file entry. This object describes the file type runtime-code (1), log-file (2), cfg-file (3)
1.3.6.1.4.1.171.12.1.2.21.1.1Integer32read-onlycurrent
agentFTPFileDscr
OBJECT-TYPE
The description of the software file purpose in this entry. Note: For systems which do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.21.1.2DisplayString (SIZE(0..64))read-writecurrent
agentFTPFileLoadType
OBJECT-TYPE
This object provides the user with a choice of uploading or downloading the selected file. Note: For systems which do not support a change of this object, setting a value to this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.21.1.3INTEGER {other(1), upload(2), download(3)}read-writecurrent
agentFTPFileAddr
OBJECT-TYPE
The IP address that the file to be downloaded is located on, or the IP address where the file will be uploaded to.
1.3.6.1.4.1.171.12.1.2.21.1.4IpAddressread-writecurrent
agentFTPTCPPort
OBJECT-TYPE
The TCP port number being used to establish the command connection.
1.3.6.1.4.1.171.12.1.2.21.1.5INTEGERread-writecurrent
agentFTPFileName
OBJECT-TYPE
The name of the file to be downloaded from, or uploaded to, the FTP server.
1.3.6.1.4.1.171.12.1.2.21.1.6DisplayString (SIZE(0..128))read-writecurrent
agentFTPUserName
OBJECT-TYPE
This is the user name to enter in upload/download.
1.3.6.1.4.1.171.12.1.2.21.1.7DisplayStringread-writecurrent
agentFTPPassword
OBJECT-TYPE
This is the password to enter for an upload/download.
1.3.6.1.4.1.171.12.1.2.21.1.8DisplayStringread-writecurrent
agentFTPFileCtrlID
OBJECT-TYPE
The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file.
1.3.6.1.4.1.171.12.1.2.21.1.9INTEGERread-writecurrent
agentFTPFileBIncrement
OBJECT-TYPE
This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase.
1.3.6.1.4.1.171.12.1.2.21.1.10TruthValueread-writecurrent
agentFTPFileCtrl
OBJECT-TYPE
This object gives the user the option to download runtime software. The setting will take effect when the system restarts. See Note (1) below Note 1: For systems which do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages.
1.3.6.1.4.1.171.12.1.2.21.1.11INTEGER {other(1), start(2)}read-writecurrent
agentFTPFileBootUpImage
OBJECT-TYPE
This object indicates whether to set the special file as a boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified.
1.3.6.1.4.1.171.12.1.2.21.1.12TruthValueread-writecurrent
agentFTPFileForceAgree
OBJECT-TYPE
When the force-agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: Force-agree option is specified. False: Force-agree option is not specified.
1.3.6.1.4.1.171.12.1.2.21.1.13TruthValueread-writecurrent
agentFTPFileIPv6Addr
OBJECT-TYPE
The IPv6 address where the file is to be downloaded from or uploaded to.
1.3.6.1.4.1.171.12.1.2.21.1.14DisplayStringread-writecurrent
agentFTPFileInterfaceName
OBJECT-TYPE
This node is used to specify the interface name when agentFTPFileIPv6Addr is the local link address.
1.3.6.1.4.1.171.12.1.2.21.1.15DisplayStringread-writecurrent
agentFTPFileUnitID
OBJECT-TYPE
Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches.
1.3.6.1.4.1.171.12.1.2.21.1.16UnitListread-writecurrent
agentSnmpTrapState
OBJECT-TYPE
This object indicates if the SNMP trap is enabled or disabled.
1.3.6.1.4.1.171.12.1.2.22INTEGER {enabled(1), disabled(2)}read-writecurrent
agentOutOfBandMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.23
agentOutOfBandMgmtState
OBJECT-TYPE
Enables or disables the interface.
1.3.6.1.4.1.171.12.1.2.23.1INTEGER {enabled(1), disabled(2)}read-writecurrent
agentOutOfBandMgmtIpAddr
OBJECT-TYPE
The IP address for out of band management. This object can only take the value of the unicast IP address.
1.3.6.1.4.1.171.12.1.2.23.2IpAddressread-writecurrent
agentOutOfBandMgmtSubnetMask
OBJECT-TYPE
The IP net mask for out of band management.
1.3.6.1.4.1.171.12.1.2.23.3IpAddressread-writecurrent
agentOutOfBandMgmtGateway
OBJECT-TYPE
The gateway for out of band management.
1.3.6.1.4.1.171.12.1.2.23.4IpAddressread-writecurrent
agentOutOfBandMgmtLinkStatus
OBJECT-TYPE
The current Link status for out of band management.
1.3.6.1.4.1.171.12.1.2.23.5INTEGER {link-up(1), link-down(2)}read-onlycurrent
agentTrapMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.24
agentTrapColdStart
OBJECT-TYPE
When enabled (1), whenever the device detects a cold start event, a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.1INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapWarmStart
OBJECT-TYPE
When enabled (1), whenever the device detects a warm start event, a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.2INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapRmonRisingAlarm
OBJECT-TYPE
When enabled (1), whenever the device detects a RMON rising alarm event , a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.3INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapRmonFallingAlarm
OBJECT-TYPE
When enabled (1), whenever the device detects a RMON falling alarm event, a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.4INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapCfgSave
OBJECT-TYPE
When enabled (1), whenever the device detects a configuration saving completed event, a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.5INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapCfgUpload
OBJECT-TYPE
When enabled (1), whenever the device detects a configuration uploading completed event, a trap will be sent out.
1.3.6.1.4.1.171.12.1.2.24.6INTEGER {enabled(1), disabled(2)}read-writecurrent
agentTrapCfgDownload
OBJECT-TYPE
When enabled (1), whenever the device detects a configuration downloading completed event, a trap will be sent out
1.3.6.1.4.1.171.12.1.2.24.7INTEGER {enabled(1), disabled(2)}read-writecurrent
agentFTPFileSystemTable
OBJECT-TYPE
The FTP management table for the file system
1.3.6.1.4.1.171.12.1.2.25not-accessiblecurrent
agentFTPFileSystemEntry
OBJECT-TYPE
A File System basic configuration entry that contains objects describing a particular MIB supported by this agent.
1.3.6.1.4.1.171.12.1.2.25.1not-accessiblecurrent
agentFTPFileSystemIndex
OBJECT-TYPE
The table index for the file entry.
1.3.6.1.4.1.171.12.1.2.25.1.1Integer32not-accessiblecurrent
agentFTPFileSystemDscr
OBJECT-TYPE
The description of the software file purpose in this entry.
1.3.6.1.4.1.171.12.1.2.25.1.2DisplayStringread-onlycurrent
agentFTPFileSystemLoadType
OBJECT-TYPE
This object allows the user to select a download or upload function for the file.
1.3.6.1.4.1.171.12.1.2.25.1.3INTEGER {other(1), upload(2), download(3)}read-writecurrent
agentFTPFileSystemAddressType
OBJECT-TYPE
The address type of agentFTPFileSystemAddress.
1.3.6.1.4.1.171.12.1.2.25.1.4InetAddressTyperead-writecurrent
agentFTPFileSystemAddress
OBJECT-TYPE
This object indicates the FTP server address.
1.3.6.1.4.1.171.12.1.2.25.1.5InetAddressread-writecurrent
agentFTPFileSystemTCPPort
OBJECT-TYPE
The TCP port number being used to establish the control connection.
1.3.6.1.4.1.171.12.1.2.25.1.6INTEGERread-writecurrent
agentFTPFileSystemServerFileName
OBJECT-TYPE
The name of the file to be downloaded from or uploaded to the FTP server.
1.3.6.1.4.1.171.12.1.2.25.1.7DisplayString (SIZE(0..64))read-writecurrent
agentFTPFileSystemDeviceFileName
OBJECT-TYPE
The name of the file to be downloaded to the device, or uploaded from the device. If agentFTPFileSystemDeviceFileName is not set, the switch will default to the bootup file.
1.3.6.1.4.1.171.12.1.2.25.1.8DisplayString (SIZE(0..64))read-writecurrent
agentFTPFileSystemUserName
OBJECT-TYPE
This object indicates the user name to access the FTP server.
1.3.6.1.4.1.171.12.1.2.25.1.9DisplayStringread-writecurrent
agentFTPFileSystemPassword
OBJECT-TYPE
This object indicates the password to access the FTP server.
1.3.6.1.4.1.171.12.1.2.25.1.10DisplayStringread-writecurrent
agentFTPFileSystemCtrlUnitID
OBJECT-TYPE
Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches.
1.3.6.1.4.1.171.12.1.2.25.1.11UnitListread-writecurrent
agentFTPFileSystemBootUpImage
OBJECT-TYPE
This object indicates whether to set the special file as the boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified.
1.3.6.1.4.1.171.12.1.2.25.1.12TruthValueread-writecurrent
agentFTPFileSystemCtrl
OBJECT-TYPE
This object allows the user to execute an FTP download/upload.
1.3.6.1.4.1.171.12.1.2.25.1.13INTEGER {other(1), start(2)}read-writecurrent
agentFTPFileSystemVrfName
OBJECT-TYPE
This object indicates the VRF name of the FTP server.Input string 'reserved' for the global space.
1.3.6.1.4.1.171.12.1.2.25.1.14DisplayString (SIZE(0..12))read-writecurrent
agentBscCMDLogState
OBJECT-TYPE
This object indicates the command logging state.
1.3.6.1.4.1.171.12.1.2.26INTEGER {enabled(1), disabled(2)}read-writecurrent
agentBscBroadcastPingReplyState
OBJECT-TYPE
This object indicates the broadcast ping reply state.
1.3.6.1.4.1.171.12.1.2.27INTEGER {enabled(1), disabled(2)}read-writecurrent
agentBscTftpConfigMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.2.28
agentBscTftpCfgFirmwareFile
OBJECT-TYPE
The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.1DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgConfigFile
OBJECT-TYPE
The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.2DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgLogFile
OBJECT-TYPE
The log pathname that needs to be uploaded to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.3DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgAttackLogFile
OBJECT-TYPE
The attack log pathname that needs to be uploaded to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.4DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgCertificateFile
OBJECT-TYPE
The certificate pathname that needs to be downloaded from the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.5DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgKeyFile
OBJECT-TYPE
The key pathname that needs to be downloaded from the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.6DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgTechSuooprtFile
OBJECT-TYPE
The technique's support information pathname that needs to be uploaded to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.7DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgDebugLogFile
OBJECT-TYPE
The debug log pathname that needs to be uploaded to the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.8DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgSIMFirmwareFile
OBJECT-TYPE
The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled.
1.3.6.1.4.1.171.12.1.2.28.9DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgSIMConfigFile
OBJECT-TYPE
The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled.
1.3.6.1.4.1.171.12.1.2.28.10DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgSIMLogFile
OBJECT-TYPE
The log pathname that needs to be uploaded to the TFTP server when it is SIM enabled.
1.3.6.1.4.1.171.12.1.2.28.11DisplayString (SIZE(0..64))read-writecurrent
agentBscTftpCfgServerIPAddr
OBJECT-TYPE
The IPv4 address of the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.12IpAddressread-writecurrent
agentBscTftpCfgServerIPv6Addr
OBJECT-TYPE
The IPv6 address of the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.13Ipv6Addressread-writecurrent
agentBscTftpCfgServerDomainName
OBJECT-TYPE
The domain name of the TFTP server.
1.3.6.1.4.1.171.12.1.2.28.14DisplayString (SIZE(0..255))read-writecurrent
agentBscCommunityEncryptionState
OBJECT-TYPE
This object indicates the encryption state on the SNMP community string.
1.3.6.1.4.1.171.12.1.2.29INTEGER {enabled(1), disabled(2)}read-writecurrent
agentSnmpUdpPort
OBJECT-TYPE
This object indicates the snmp udp port number.
1.3.6.1.4.1.171.12.1.2.30INTEGER (1..65535)read-writecurrent
agentResponseBroadcastRequest
OBJECT-TYPE
This object indicates the response broadcast request state.
1.3.6.1.4.1.171.12.1.2.31INTEGER {disabled(1), enabled(2)}read-writecurrent
agentIpProtoConfig
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.3
agentIpNumOfIf
OBJECT-TYPE
The total number of IP interfaces supported by this agent.
1.3.6.1.4.1.171.12.1.3.1Integer32read-onlycurrent
agentIpTftpServerAddr
OBJECT-TYPE
The IP address of the TFTP Server.
1.3.6.1.4.1.171.12.1.3.2IpAddressread-writeobsolete
agentIpGetIpFrom
OBJECT-TYPE
This object indicates if the agent will get its system IP address from a Bootp/DHCP server at start up.
1.3.6.1.4.1.171.12.1.3.3INTEGER {other(1), disabled(2), bootp(3), dhcp(4)}read-writecurrent
agentIpAutoconfig
OBJECT-TYPE
Indicates the status of automatically getting the configuration information from a TFTP server connected to the device.
1.3.6.1.4.1.171.12.1.3.4INTEGER {enabled(1), disabled(2)}read-writecurrent
agentIpAutoconfigTimeout
OBJECT-TYPE
This timer is used to limit the length of time for getting the configuration information from a TFTP server connected to the device.
1.3.6.1.4.1.171.12.1.3.5Integer32read-writecurrent
agentIpTrapManager
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.4
agentTrapManagerTable
OBJECT-TYPE
A list of trap managers that the SNMP traps will be sent to.
1.3.6.1.4.1.171.12.1.4.2not-accessiblecurrent
agentTrapManagerEntry
OBJECT-TYPE
Each entry contains the particular trap manager's settings.
1.3.6.1.4.1.171.12.1.4.2.1not-accessiblecurrent
agentTrapManagerIndex
OBJECT-TYPE
A value that uniquely identifies trapDestEntry.
1.3.6.1.4.1.171.12.1.4.2.1.1INTEGER (1..65535)not-accessiblecurrent
agentTrapManagerIpAddr
OBJECT-TYPE
The destination IP address for SNMP traps.
1.3.6.1.4.1.171.12.1.4.2.1.2IpAddressread-writecurrent
agentTrapManagerComm
OBJECT-TYPE
The community string used to encode SNMP trap packets being sent to the trap manager.
1.3.6.1.4.1.171.12.1.4.2.1.3DisplayString (SIZE(0..20))read-writecurrent
agentTrapManagerMsgVer
OBJECT-TYPE
This object indicates the version of trap packets that will be sent to this trap manager. The default setting is SNMP Agent Version Dependent. Note: Because some of these functions will be limited by the support of the system in question, some selected items may be invalid. If one of these items is selected, a bad value error message will prompt the user.
1.3.6.1.4.1.171.12.1.4.2.1.4INTEGER {snmpAgentVersionDependent(1), v1Trap(2), v2Trap(3)}read-writecurrent
agentTrapManagerStatus
OBJECT-TYPE
This object indicates whether or not the trap should be sent to the trap manager.
1.3.6.1.4.1.171.12.1.4.2.1.5INTEGER {other(1), disabled(2), enabled(3)}read-writecurrent
agentTrapManagerUdpPort
OBJECT-TYPE
This object indicates the Trap udp port number.
1.3.6.1.4.1.171.12.1.4.2.1.6INTEGER (1..65535)read-writecurrent
agentPortTrapStateTable
OBJECT-TYPE
Use to Set/Get per port trap state.
1.3.6.1.4.1.171.12.1.4.3not-accessiblecurrent
agentPortTrapStateEntry
OBJECT-TYPE
This is an entry of the agentPortTrapStateTable.
1.3.6.1.4.1.171.12.1.4.3.1not-accessiblecurrent
agentTrapStatePortIndex
OBJECT-TYPE
This object indicates the port number.
1.3.6.1.4.1.171.12.1.4.3.1.1INTEGER (1..65535)not-accessiblecurrent
agentPortTrapState
OBJECT-TYPE
This object indicates the port trap status.
1.3.6.1.4.1.171.12.1.4.3.1.2INTEGER {enabled(1), disabled(2)}read-writecurrent
agentNotify
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7
agentNotifMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7.1
notifFirmwareMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7.1.2
agentNotifFirmware
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7.2
agentNotifyPrefix
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7.2.0
notificationBindings
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.1.7.2.1
unitID
OBJECT-TYPE
The unit ID of the device which triggered the event.
1.3.6.1.4.1.171.12.1.7.2.1.1INTEGERaccessible-for-notifycurrent
trapInfosystemRestart
OBJECT-TYPE
This object indicates the last time the device rebooted.
1.3.6.1.4.1.171.12.1.7.2.1.2DisplayString (SIZE(0..64))read-onlycurrent
agentGratuitousARPIpAddr
OBJECT-TYPE
A duplicate IP address with the switch already exists.
1.3.6.1.4.1.171.12.1.7.2.1.3IpAddressaccessible-for-notifycurrent
agentGratuitousARPMacAddr
OBJECT-TYPE
This object is the MAC address of the device which has the duplicate IP address.
1.3.6.1.4.1.171.12.1.7.2.1.4MacAddressaccessible-for-notifycurrent
agentGratuitousARPPortNumber
OBJECT-TYPE
This indicates the portNum with a string. For example, if the device is in standalone mode, and the port number is 23, the string should be 23. If the device is in stacking mode, and the unit ID is 2, and the port number is 3, the string should be 2:3.
1.3.6.1.4.1.171.12.1.7.2.1.5DisplayStringaccessible-for-notifycurrent
agentLoginType
OBJECT-TYPE
The type is the user login method type.
1.3.6.1.4.1.171.12.1.7.2.1.6INTEGER {console(1), telnet(2), web(3), ssl(4), ssh(5)}accessible-for-notifycurrent
agentLoginAAAMethod
OBJECT-TYPE
This method is the AAA login method.
1.3.6.1.4.1.171.12.1.7.2.1.7INTEGER {none(1), local(2), server(3)}accessible-for-notifycurrent
agentLoginUserName
OBJECT-TYPE
This object is the name of the user that failed to login to the switch.
1.3.6.1.4.1.171.12.1.7.2.1.8DisplayStringaccessible-for-notifycurrent
agentLoginIpAddr
OBJECT-TYPE
This object is the login type from the IP address.
1.3.6.1.4.1.171.12.1.7.2.1.9IpAddressaccessible-for-notifycurrent
agentLoginMacAddr
OBJECT-TYPE
This object is the login type from a MAC address.
1.3.6.1.4.1.171.12.1.7.2.1.10MacAddressaccessible-for-notifycurrent
agentLoginAAAServerAddr
OBJECT-TYPE
This object is the login type through a console authenticated by an AAA server.
1.3.6.1.4.1.171.12.1.7.2.1.11IpAddressaccessible-for-notifycurrent
agentLoginFailInfo
OBJECT-TYPE
This object indicates the reason for the login failure.
1.3.6.1.4.1.171.12.1.7.2.1.12INTEGER {other(1), authenticate-fail(2), server-timeout(3)}accessible-for-notifycurrent
agentAccessFlashOper
OBJECT-TYPE
This object indicates the operation of the access flash failure.
1.3.6.1.4.1.171.12.1.7.2.1.13DisplayString (SIZE(0..64))accessible-for-notifycurrent
agentAccessFlashAddr
OBJECT-TYPE
This object indicates the address of the access flash failure.
1.3.6.1.4.1.171.12.1.7.2.1.14INTEGERaccessible-for-notifycurrent
agentCfgOperate
OBJECT-TYPE
This object indicates the operation type of the configuration.
1.3.6.1.4.1.171.12.1.7.2.1.15INTEGER {save(1), upload(2), download(3)}accessible-for-notifycurrent

Notifications

NameOIDStatus
agentsystemRestart
NOTIFICATION-TYPE
This trap contains the reboot information.
1.3.6.1.4.1.171.12.1.7.2.0.1current
agentSaveToNVRAM
NOTIFICATION-TYPE
This trap is sent whenever all the device configuration has been saved to NV-RAM.
1.3.6.1.4.1.171.12.1.7.2.0.2current
agentFileTransferStatusChange
NOTIFICATION-TYPE
File transfer status change notification.
1.3.6.1.4.1.171.12.1.7.2.0.3current
agentSetToFactoryDefault
NOTIFICATION-TYPE
This trap is sent whenever the 'set to factory default' setting has been processed.
1.3.6.1.4.1.171.12.1.7.2.0.4current
agentGratuitousARPTrap
NOTIFICATION-TYPE
This trap is sent when there is an IP address conflict.
1.3.6.1.4.1.171.12.1.7.2.0.5current
agentLoginFailTrap
NOTIFICATION-TYPE
The trap is sent when a login has failed through one of the login types (console, Telnet, web, SSL or SSH).
1.3.6.1.4.1.171.12.1.7.2.0.6current
agentFirmwareUpgrade
NOTIFICATION-TYPE
This trap is sent when the process of upgrading the firmware via SNMP has finished.
1.3.6.1.4.1.171.12.1.7.2.0.7current
agentAccessFlashFailed
NOTIFICATION-TYPE
The trap is sent when access to the flash fails.
1.3.6.1.4.1.171.12.1.7.2.0.8current
agentCfgOperCompleteTrap
NOTIFICATION-TYPE
The trap is sent when the configuration is completely saved, uploaded or downloaded.
1.3.6.1.4.1.171.12.1.7.2.0.9current