ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB
- Registered at
- 1.3.6.1.4.1.664.5.53.1.10.01.3.6.1.4.1.664.5.53.99.191.3.6.1.4.1.664.6.10000.53.1.10
- Last updated
- 2014-11-04 16:15
- Organization
- ADTRAN, Inc.
- Revisions
- 2014-11-04 16:15
- Namespace
- adtran
- Source file
ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB- Digest
sha256:d18db0e7ba193fb7ac82bd7e06137dcbdc7bcefcd0deb358d996e0f631cd49fb
Description
The MIB module defines over-temperature configuration information and traps for AdtranOS products.
Contact
Technical Support Dept. Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com
Imports
| From | Symbols |
|---|---|
| ADTRAN-AOS | adGenAOSCommon, adGenAOSConformance |
| ADTRAN-MIB | adIdentity |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ADTRAN-AOS ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB ADTRAN-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| adGenAOSOverTempProtection OBJECT-IDENTITY | 1.3.6.1.4.1.664.5.53.1.10 | |||
| adGenAOSOverTempProtectionTrap OBJECT-IDENTITY | 1.3.6.1.4.1.664.5.53.1.10.0 | |||
| adGenAOSOverTempProtectionConformance OBJECT-IDENTITY | 1.3.6.1.4.1.664.5.53.99.19 | |||
| adGenAOSOverTempProtectionGroups OBJECT-IDENTITY | 1.3.6.1.4.1.664.5.53.99.19.1 | |||
| adGenAOSOverTempProtectionCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.664.5.53.99.19.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| adGenAOSOverTempProtectionWarning NOTIFICATION-TYPE An over-temperature warning trap signifies that the warning temperature threshold has been exceeded. | 1.3.6.1.4.1.664.5.53.1.10.0.1 | current |
| adGenAOSOverTempProtectionShutdown NOTIFICATION-TYPE An over-temperature shutdown trap signifies that the shutdown temperature threshold has been exceeded, and the unit will restart into low-power mode. | 1.3.6.1.4.1.664.5.53.1.10.0.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| adGenAOSOverTempProtectionNotificationGroup NOTIFICATION-GROUP Traps which may be used to enhance event driven management of the chassis's over-temperature protection subsystem. | 1.3.6.1.4.1.664.5.53.99.19.1.1 | current |
| adGenAOSOverTempProtectionFullCompliance MODULE-COMPLIANCE The compliance statement for SNMP entities which implement version 2 of the adGenAosOverTempProtection MIB. When the implementation of this MIB supports adGenAOSOverTempProtectionNotificationGroup, then such an implementation can claim full compliance. | 1.3.6.1.4.1.664.5.53.99.19.2.1 | current |