MIBs Depot

ACS8000-MIB

Registered at
1.3.6.1.4.1.10418.26.1.1
1.3.6.1.4.1.10418.26.1.2
1.3.6.1.4.1.10418.26.1.3
1.3.6.1.4.1.10418.26.1.4
1.3.6.1.4.1.10418.26.1.5
1.3.6.1.4.1.10418.26.1.6
1.3.6.1.4.1.10418.26.1.7
1.3.6.1.4.1.10418.26.2.1
1.3.6.1.4.1.10418.26.2.2
1.3.6.1.4.1.10418.26.2.3
1.3.6.1.4.1.10418.26.2.5
1.3.6.1.4.1.10418.26.2.7
1.3.6.1.4.1.10418.26.2.8
Last updated
2024-05-01 00:00
Organization
Vertiv Co
Revisions
2023-09-06 00:00, 2022-01-25 00:00, 2021-04-19 00:00, 2020-10-01 00:00, 2020-07-01 00:00, 2019-06-01 00:00, 2018-05-01 00:00, 2017-11-17 00:00, 2016-06-17 00:00, 2016-01-06 00:00, 2010-10-10 00:00, 2007-09-17 00:00
Namespace
avocent
Source file
ACS8000-MIB
Digest
sha256:0262909de5f6641a7d239b9699e329c6ed6f3c1b7e61f00dfdd109b9bcff9246

Description

This module defines the MIB extensions to ACS80xx products.

Contact

e-mail : support.avocent@vertiv.com Web : www.vertiv.com

Imports

FromSymbols
IF-MIBInterfaceIndex, InterfaceIndexOrZero
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ACS8000-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
PowerSupplyState
type
SerialPortPinOut
type
SerialPortSignalState
type
SerialPortSpeed
type

Objects

NameOIDSyntaxAccessStatus
avocent
OBJECT-IDENTITY
1.3.6.1.4.1.10418
acsProducts
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1
acs8048
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.1
acs8032
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.2
acs8016
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.3
acs8008
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.4
acs808
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.5
acs804
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.6
acs802
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.1.7
acsManagement
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2
acsAppliance
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.1
acsHostName
OBJECT-TYPE
The appliance name
1.3.6.1.4.1.10418.26.2.1.1DisplayString (SIZE(0..32))read-onlycurrent
acsProductModel
OBJECT-TYPE
The appliance product model
1.3.6.1.4.1.10418.26.2.1.2DisplayString (SIZE(0..50))read-onlycurrent
acsPartNumber
OBJECT-TYPE
The part number of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.3DisplayString (SIZE(0..32))read-onlycurrent
acsSerialNumber
OBJECT-TYPE
The serial number of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.4DisplayString (SIZE(0..32))read-onlycurrent
acsEIDNumber
OBJECT-TYPE
The electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.5DisplayString (SIZE(0..32))read-onlycurrent
acsBootcodeVersion
OBJECT-TYPE
The version of the bootcode of this appliance.
1.3.6.1.4.1.10418.26.2.1.6DisplayString (SIZE(0..32))read-onlycurrent
acsFirmwareVersion
OBJECT-TYPE
The version of the firmware of this appliance.
1.3.6.1.4.1.10418.26.2.1.7DisplayString (SIZE(0..32))read-onlycurrent
acsPowerSupply
OBJECT-IDENTITY
It gives information about Power Supply of this appliance
1.3.6.1.4.1.10418.26.2.1.8current
acsPowerSupplyNumber
OBJECT-TYPE
Number of the power supplies of this appliance
1.3.6.1.4.1.10418.26.2.1.8.1Integer32read-onlycurrent
acsPowerSupplyStatePw1
OBJECT-TYPE
State of the first power supply
1.3.6.1.4.1.10418.26.2.1.8.2PowerSupplyStateread-onlycurrent
acsPowerSupplyStatePw2
OBJECT-TYPE
State of the second power supply
1.3.6.1.4.1.10418.26.2.1.8.3PowerSupplyStateread-onlycurrent
acsReboot
OBJECT-TYPE
A set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately reboots.
1.3.6.1.4.1.10418.26.2.1.9INTEGER {noAction(1), reboot(2)}read-writecurrent
acsScheduledTasksTable
OBJECT-TYPE
This table contains the list of the scheduled tasks.
1.3.6.1.4.1.10418.26.2.1.10not-accessiblecurrent
acsScheduledTasksTableEntry
OBJECT-TYPE
each entry has the information about the scheduled task
1.3.6.1.4.1.10418.26.2.1.10.1not-accessiblecurrent
acsScheduledTasksTableIndex
OBJECT-TYPE
A unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.1.10.1.1InterfaceIndexOrZeroread-onlycurrent
acsScheduledTasksTableType
OBJECT-TYPE
The type of the scheduled task.
1.3.6.1.4.1.10418.26.2.1.10.1.2INTEGER {custom(1), cell-modem-ip-test(2), cell-modem-signal-check(3), save-config-cli(4)}read-onlycurrent
acsScheduledTasksTableName
OBJECT-TYPE
Name of the scheduled task.
1.3.6.1.4.1.10418.26.2.1.10.1.3DisplayString (SIZE(0..32))read-onlycurrent
acsScheduledTasksTableStatus
OBJECT-TYPE
When set to enabled, the task will be run according to the schedule defined by acsScheduledTasksTableFrequency.
1.3.6.1.4.1.10418.26.2.1.10.1.4INTEGER {disabled(1), enabled(2)}read-writecurrent
acsScheduledTasksTableFrequency
OBJECT-TYPE
This object defines how often the task will be run. When set to hourly(1), the task will be run every hour. When set to daily(2), the task will be run every day at the time specified by acsScheduledTasksTableTime. When set to weekly(3), the task will be run every week on the day specified by acsScheduledTasksTableDay, at the time specified by acsScheduledTasksTableTime. When set to monthly(4), the task will be run every month on the day specified by acsScheduledTasksTableDate, at the time specified by acsScheduledTasksTableTime.
1.3.6.1.4.1.10418.26.2.1.10.1.5INTEGER {hourly(1), daily(2), weekly(3), monthly(4)}read-writecurrent
acsScheduledTasksTableDay
OBJECT-TYPE
Only used if acsScheduledTasksTableFrequency is set to weekly(3). The task will be run every week on this day, at the time specified by acsScheduledTasksTableTime.
1.3.6.1.4.1.10418.26.2.1.10.1.6INTEGER {sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)}read-writecurrent
acsScheduledTasksTableDate
OBJECT-TYPE
Only used if acsScheduledTasksTableFrequency is set to monthly(4). The task will be run every month on this day, at the time specified by acsScheduledTasksTableTime.
1.3.6.1.4.1.10418.26.2.1.10.1.7Integer32read-writecurrent
acsScheduledTasksTableTime
OBJECT-TYPE
The time of day the task will run. Format must be HH:MM.
1.3.6.1.4.1.10418.26.2.1.10.1.8DisplayString (SIZE(0..32))read-writecurrent
acsScheduledTasksTableLastStarted
OBJECT-TYPE
The timestamp of the last time the task started running.
1.3.6.1.4.1.10418.26.2.1.10.1.9DisplayString (SIZE(0..32))read-onlycurrent
acsScheduledTasksTableLastResult
OBJECT-TYPE
The result of the last time the task was run.
1.3.6.1.4.1.10418.26.2.1.10.1.10DisplayString (SIZE(0..256))read-onlycurrent
acsScheduledTasksTableScript
OBJECT-TYPE
The script command used by the task. Only used if acsScheduledTasksTableType is set to custom(1).
1.3.6.1.4.1.10418.26.2.1.10.1.11DisplayString (SIZE(0..128))read-writecurrent
acsScheduledTasksTableIpAddress
OBJECT-TYPE
The IP address used by the cell-modem-ip task. Not used by all tasks.
1.3.6.1.4.1.10418.26.2.1.10.1.12DisplayString (SIZE(0..32))read-writecurrent
acsSessions
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.2
acsActiveSessionsNumberOfSession
OBJECT-TYPE
Number of active sessions.
1.3.6.1.4.1.10418.26.2.2.1Integer32read-onlycurrent
acsActiveSessionsTable
OBJECT-TYPE
This table contains the list of active sessions.
1.3.6.1.4.1.10418.26.2.2.2not-accessiblecurrent
acsActiveSessionsTableEntry
OBJECT-TYPE
each entry has the information about the active session
1.3.6.1.4.1.10418.26.2.2.2.1not-accessiblecurrent
acsActiveSessionsTableIndex
OBJECT-TYPE
A unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.2.2.1.1InterfaceIndexOrZeroread-onlycurrent
acsActiveSessionsTableUser
OBJECT-TYPE
The name of the user that opens this session.
1.3.6.1.4.1.10418.26.2.2.2.1.2DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableGroup
OBJECT-TYPE
The name of the group that the user belongs to.
1.3.6.1.4.1.10418.26.2.2.2.1.3DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableType
OBJECT-TYPE
The session type.
1.3.6.1.4.1.10418.26.2.2.2.1.4DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableConnection
OBJECT-TYPE
Connection type.
1.3.6.1.4.1.10418.26.2.2.2.1.5DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableSessionTime
OBJECT-TYPE
Time of the session
1.3.6.1.4.1.10418.26.2.2.2.1.6DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableFrom
OBJECT-TYPE
The source IP address of the session.
1.3.6.1.4.1.10418.26.2.2.2.1.7DisplayString (SIZE(0..32))read-onlycurrent
acsActiveSessionsTableKill
OBJECT-TYPE
A set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immediately kills the session.
1.3.6.1.4.1.10418.26.2.2.2.1.8INTEGER {noAction(1), killSession(2)}read-writecurrent
acsSerialPort
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.3
acsSerialPortNumberOfPorts
OBJECT-TYPE
Number of Serial Ports (physical serial port plus Aux Port.
1.3.6.1.4.1.10418.26.2.3.1Integer32read-onlycurrent
acsSerialPortTable
OBJECT-TYPE
This table contains information about serial ports.
1.3.6.1.4.1.10418.26.2.3.2not-accessiblecurrent
acsSerialPortTableEntry
OBJECT-TYPE
each entry has the information about specific serial port.
1.3.6.1.4.1.10418.26.2.3.2.1not-accessiblecurrent
acsSerialPortTableNumber
OBJECT-TYPE
A unique index representing an entry in this table. It is the number of the serial port. For AUX port, the number will be the number of physical serial ports plus 1.
1.3.6.1.4.1.10418.26.2.3.2.1.1Integer32 (1..49)read-onlycurrent
acsSerialPortTableDeviceName
OBJECT-TYPE
The associated device name for the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.2DisplayString (SIZE(0..25))read-onlycurrent
acsSerialPortTableStatus
OBJECT-TYPE
The status of the serial port: disabled(1) = it was configured as disable. idle(2) = there is not any session opened in this port. inUse(3) = there is session(s) opened in this port.
1.3.6.1.4.1.10418.26.2.3.2.1.3INTEGER {disabled(1), idle(2), inUse(3)}read-onlycurrent
acsSerialPortTableName
OBJECT-TYPE
Name associated with this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.4DisplayString (SIZE(0..25))read-onlycurrent
acsSerialPortTableProfile
OBJECT-TYPE
Configured profile for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.5INTEGER {casProfile(1), tsProfile(2), dialInProfile(3), powerProfile(4)}read-onlycurrent
acsSerialPortTablePinOut
OBJECT-TYPE
RJ45 Pin-out configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.6SerialPortPinOutread-onlycurrent
acsSerialPortTableComSpeed
OBJECT-TYPE
Speed configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.7SerialPortSpeedread-onlycurrent
acsSerialPortTableComParity
OBJECT-TYPE
Parity configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.8INTEGER {none(1), odd(2), even(3)}read-onlycurrent
acsSerialPortTableComDataSize
OBJECT-TYPE
Data Size configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.9Integer32read-onlycurrent
acsSerialPortTableComStopBits
OBJECT-TYPE
Number of Stop Bits configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.10Integer32read-onlycurrent
acsSerialPortTableComFlowControl
OBJECT-TYPE
Flow Control configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.11INTEGER {none(1), hardware(2), software(3)}read-onlycurrent
acsSerialPortTableSignalStateDTR
OBJECT-TYPE
State of the DTR RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.12SerialPortSignalStateread-onlycurrent
acsSerialPortTableSignalStateDCD
OBJECT-TYPE
State of the DCD RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.13SerialPortSignalStateread-onlycurrent
acsSerialPortTableSignalStateRTS
OBJECT-TYPE
State of the RTS RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.14SerialPortSignalStateread-onlycurrent
acsSerialPortTableSignalStateCTS
OBJECT-TYPE
State of the CTS RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.15SerialPortSignalStateread-onlycurrent
acsSerialPortTableTxBytes
OBJECT-TYPE
The number of transmited bytes by the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.16Integer32read-onlycurrent
acsSerialPortTableRxBytes
OBJECT-TYPE
The number of received bytes by the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.17Integer32read-onlycurrent
acsSerialPortTableFrameError
OBJECT-TYPE
The number of frame error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.18Integer32read-onlycurrent
acsSerialPortTableParityError
OBJECT-TYPE
The number of parity error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.19Integer32read-onlycurrent
acsSerialPortTableBreak
OBJECT-TYPE
The number of break detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.20Integer32read-onlycurrent
acsSerialPortTableOverrun
OBJECT-TYPE
The number of overrun error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.21Integer32read-onlycurrent
acsSerialPortTableResetCounters
OBJECT-TYPE
Resets counters for all statistics for this serial port. Resets the countes for TxBytes, RxBytes, frame errors, parity errors, breaks, and overrun errors.
1.3.6.1.4.1.10418.26.2.3.2.1.22INTEGER {no-action(1), resetCounters(2)}read-writecurrent
acsSerialPortTableXcvrStatus
OBJECT-TYPE
Activity status of the RS232 transceiver.
1.3.6.1.4.1.10418.26.2.3.2.1.23SerialPortSignalStateread-onlycurrent
acsPowerMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.5
acsPowerMgmtNumSerialPorts
OBJECT-TYPE
The number of Serial Ports that has PDU connected on the appliance.
1.3.6.1.4.1.10418.26.2.5.1Integer32read-onlycurrent
acsPowerMgmtSerialTable
OBJECT-TYPE
Information about each serial port thas has PDU connect.
1.3.6.1.4.1.10418.26.2.5.2not-accessiblecurrent
acsPowerMgmtSerialTableEntry
OBJECT-TYPE
Information about each serial port thas has PDU connect.
1.3.6.1.4.1.10418.26.2.5.2.1not-accessiblecurrent
acsPowerMgmtSerialTableIndex
OBJECT-TYPE
The index of the register.
1.3.6.1.4.1.10418.26.2.5.2.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtSerialTablePortNumber
OBJECT-TYPE
The number of the serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.2.1.2Integer32read-onlycurrent
acsPowerMgmtSerialTableDeviceName
OBJECT-TYPE
The device name of this serial port.
1.3.6.1.4.1.10418.26.2.5.2.1.3DisplayStringread-onlycurrent
acsPowerMgmtSerialTableNumberPDUs
OBJECT-TYPE
Total number of units connected in this serial port.
1.3.6.1.4.1.10418.26.2.5.2.1.4Integer32read-onlycurrent
acsPowerMgmtSerialTableNumberUPS
OBJECT-TYPE
Total number of UPS devices connected to this serial port.
1.3.6.1.4.1.10418.26.2.5.2.1.5Integer32read-onlycurrent
acsPowerMgmtPDUTable
OBJECT-TYPE
This table contains the list of detected PDUs.
1.3.6.1.4.1.10418.26.2.5.3not-accessiblecurrent
acsPowerMgmtPDUTableEntry
OBJECT-TYPE
each entry has the information about the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1not-accessiblecurrent
acsPowerMgmtPDUTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.3.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtPDUTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.3.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtPDUTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.3.1.3DisplayStringread-onlycurrent
acsPowerMgmtPDUTablePortName
OBJECT-TYPE
Name of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.3.1.4DisplayStringread-onlycurrent
acsPowerMgmtPDUTableModel
OBJECT-TYPE
Model of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.5DisplayStringread-onlycurrent
acsPowerMgmtPDUTableVendor
OBJECT-TYPE
Vendor of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.6DisplayStringread-onlycurrent
acsPowerMgmtPDUTableFirmwareVersion
OBJECT-TYPE
Version of the PDU firmware.
1.3.6.1.4.1.10418.26.2.5.3.1.7DisplayStringread-onlycurrent
acsPowerMgmtPDUTableNumberOfOutlets
OBJECT-TYPE
Number of outlets of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.8Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentNOS
OBJECT-TYPE
Number of current sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.9Integer32read-onlyobsolete
acsPowerMgmtPDUTableCurrent1Value
OBJECT-TYPE
Current of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)
1.3.6.1.4.1.10418.26.2.5.3.1.10Integer32read-onlyobsolete
acsPowerMgmtPDUTableCurrent1Max
OBJECT-TYPE
Maximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.
1.3.6.1.4.1.10418.26.2.5.3.1.11Integer32read-writeobsolete
acsPowerMgmtPDUTableCurrent2Value
OBJECT-TYPE
Current of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)
1.3.6.1.4.1.10418.26.2.5.3.1.12Integer32read-onlyobsolete
acsPowerMgmtPDUTableCurrent2Max
OBJECT-TYPE
Maximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.
1.3.6.1.4.1.10418.26.2.5.3.1.13Integer32read-writeobsolete
acsPowerMgmtPDUTableCurrent3Value
OBJECT-TYPE
Current of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)
1.3.6.1.4.1.10418.26.2.5.3.1.14Integer32read-onlyobsolete
acsPowerMgmtPDUTableCurrent3Max
OBJECT-TYPE
Maximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.
1.3.6.1.4.1.10418.26.2.5.3.1.15Integer32read-writeobsolete
acsPowerMgmtPDUTableTemperatureNOS
OBJECT-TYPE
Number of temperature sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.16Integer32read-onlyobsolete
acsPowerMgmtPDUTableTemperature1Value
OBJECT-TYPE
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
1.3.6.1.4.1.10418.26.2.5.3.1.17Integer32read-onlyobsolete
acsPowerMgmtPDUTableTemperature1Max
OBJECT-TYPE
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.18Integer32read-writeobsolete
acsPowerMgmtPDUTableTemperature2Value
OBJECT-TYPE
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
1.3.6.1.4.1.10418.26.2.5.3.1.19Integer32read-onlyobsolete
acsPowerMgmtPDUTableTemperature2Max
OBJECT-TYPE
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.20Integer32read-writeobsolete
acsPowerMgmtPDUTableTemperature3Value
OBJECT-TYPE
Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
1.3.6.1.4.1.10418.26.2.5.3.1.21Integer32read-onlyobsolete
acsPowerMgmtPDUTableTemperature3Max
OBJECT-TYPE
Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.22Integer32read-writeobsolete
acsPowerMgmtPDUTableHumidityNOS
OBJECT-TYPE
Number of humidity sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.23Integer32read-onlyobsolete
acsPowerMgmtPDUTableHumidity1Value
OBJECT-TYPE
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.24Integer32read-onlyobsolete
acsPowerMgmtPDUTableHumidity1Max
OBJECT-TYPE
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.25Integer32read-writeobsolete
acsPowerMgmtPDUTableHumidity2Value
OBJECT-TYPE
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.26Integer32read-onlyobsolete
acsPowerMgmtPDUTableHumidity2Max
OBJECT-TYPE
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.27Integer32read-writeobsolete
acsPowerMgmtPDUTableHumidity3Value
OBJECT-TYPE
Humidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.28Integer32read-onlyobsolete
acsPowerMgmtPDUTableHumidity3Max
OBJECT-TYPE
Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.
1.3.6.1.4.1.10418.26.2.5.3.1.29Integer32read-writeobsolete
acsPowerMgmtPDUTableVoltageNOS
OBJECT-TYPE
Number of voltage sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.30Integer32read-onlyobsolete
acsPowerMgmtPDUTableVoltage1Value
OBJECT-TYPE
Voltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.31Integer32read-onlyobsolete
acsPowerMgmtPDUTableVoltage1Max
OBJECT-TYPE
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.32Integer32read-writeobsolete
acsPowerMgmtPDUTableVoltage2Value
OBJECT-TYPE
Voltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.33Integer32read-onlyobsolete
acsPowerMgmtPDUTableVoltage2Max
OBJECT-TYPE
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.34Integer32read-writeobsolete
acsPowerMgmtPDUTableVoltage3Value
OBJECT-TYPE
Voltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.35Integer32read-onlyobsolete
acsPowerMgmtPDUTableVoltage3Max
OBJECT-TYPE
Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.36Integer32read-writeobsolete
acsPowerMgmtPDUTableNumberOfPhases
OBJECT-TYPE
Number of phases of this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.37INTEGER {single-phase(0), three-phase(3)}read-onlycurrent
acsPowerMgmtPDUTableNumberOfBanks
OBJECT-TYPE
Number of banks of this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.38Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentValue
OBJECT-TYPE
Actual value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.39Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentMax
OBJECT-TYPE
Max detected value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.40Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentMin
OBJECT-TYPE
Min detected value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.41Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentAvg
OBJECT-TYPE
Average value for current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.42Integer32read-onlycurrent
acsPowerMgmtPDUTableCurrentReset
OBJECT-TYPE
Reset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.3.1.43INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPDUTableVoltageType
OBJECT-TYPE
Type of voltage values.
1.3.6.1.4.1.10418.26.2.5.3.1.44INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPDUTableVoltageValue
OBJECT-TYPE
Actual value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.45Integer32read-onlycurrent
acsPowerMgmtPDUTableVoltageMax
OBJECT-TYPE
Max detected value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.46Integer32read-onlycurrent
acsPowerMgmtPDUTableVoltageMin
OBJECT-TYPE
Min detected value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.47Integer32read-onlycurrent
acsPowerMgmtPDUTableVoltageAvg
OBJECT-TYPE
Average value for voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.48Integer32read-onlycurrent
acsPowerMgmtPDUTableVoltageReset
OBJECT-TYPE
Reset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.49INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPDUTablePowerType
OBJECT-TYPE
Type of power consumption values.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.50INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPDUTablePowerValue
OBJECT-TYPE
Actual value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.51Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerMax
OBJECT-TYPE
Max detected value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.52Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerMin
OBJECT-TYPE
Min detected value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.53Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerAvg
OBJECT-TYPE
Average value for power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.54Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerReset
OBJECT-TYPE
Reset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.3.1.55INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPDUTablePowerFactorType
OBJECT-TYPE
Type of power factor values.
1.3.6.1.4.1.10418.26.2.5.3.1.56INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPDUTablePowerFactorValue
OBJECT-TYPE
Actual value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.57Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerFactorMax
OBJECT-TYPE
Max detected value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.58Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerFactorMin
OBJECT-TYPE
Min detected value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.59Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerFactorAvg
OBJECT-TYPE
Average value for power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.60Integer32read-onlycurrent
acsPowerMgmtPDUTablePowerFactorReset
OBJECT-TYPE
Reset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.3.1.61INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPDUTableAlarm
OBJECT-TYPE
Show the PDU alarm status.
1.3.6.1.4.1.10418.26.2.5.3.1.62INTEGER {normal(1), blow-fuse(2), hw-ocp(3), high-critical(4), high-warning(5), low-warning(6), low-critical(7), inlet-alarm(8)}read-onlycurrent
acsPowerMgmtPDUTableEnvSensors
OBJECT-TYPE
Number of environmental sensor in this PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.63Integer32read-onlycurrent
acsPowerMgmtPDUTableAgentSerialNumber
OBJECT-TYPE
Serial number of the agent.
1.3.6.1.4.1.10418.26.2.5.3.1.64DisplayStringread-onlycurrent
acsPowerMgmtPDUTablePduModelNumber
OBJECT-TYPE
Model number of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.65DisplayStringread-onlycurrent
acsPowerMgmtPDUTablePduSerialNumber
OBJECT-TYPE
Serial number of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.66DisplayStringread-onlycurrent
acsPowerMgmtPDUTablePduPartNumber
OBJECT-TYPE
Part number of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.67DisplayStringread-onlycurrent
acsPowerMgmtPDUTableAggregation
OBJECT-TYPE
Aggregation status for the PDU. Only applicable if acsPowerMgmtPDUTableVendor is 'Geist' and acsPowerMgmtPDUTablePduIndex is 1.
1.3.6.1.4.1.10418.26.2.5.3.1.68INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsPowerMgmtPDUTableBaudRate
OBJECT-TYPE
Baud rate for the PDU serial port. Only applicable if acsPowerMgmtPDUTableVendor is 'Geist' and acsPowerMgmtPDUTablePduIndex is 1.
1.3.6.1.4.1.10418.26.2.5.3.1.69SerialPortSpeedread-writecurrent
acsPowerMgmtPDUTablePduReboot
OBJECT-TYPE
A set value of reboot(2) will reboot the PDU controller. Does not affect outlet status. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the ACS will send the PDU the command to immediately reboot. Only applicable if acsPowerMgmtPDUTablePduIndex is 1.
1.3.6.1.4.1.10418.26.2.5.3.1.70INTEGER {noAction(1), reboot(2)}read-writecurrent
acsPowerMgmtPDUTablePduRefresh
OBJECT-TYPE
A set value of refresh(2) will cause the PDU to be rediscovered. Does not affect outlet status. noAction(1) = always returned in a GET. Only applicable if acsPowerMgmtPDUTablePduIndex is 1.
1.3.6.1.4.1.10418.26.2.5.3.1.71INTEGER {no-action(1), refresh(2)}read-writecurrent
acsPowerMgmtPDUTableNumberOfInlets
OBJECT-TYPE
Number of inlets on this PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.72Integer32read-onlycurrent
acsPowerMgmtTotalNumberOfOutlets
OBJECT-TYPE
Number of outlets managed by the appliance.
1.3.6.1.4.1.10418.26.2.5.4Integer32read-onlycurrent
acsPowerMgmtOutletsTable
OBJECT-TYPE
This table contains the information about outlets.
1.3.6.1.4.1.10418.26.2.5.5not-accessiblecurrent
acsPowerMgmtOutletsTableEntry
OBJECT-TYPE
each entry has the information about the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1not-accessiblecurrent
acsPowerMgmtOutletsTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.5.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtOutletsTablePduNumber
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.5.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtOutletsTableNumber
OBJECT-TYPE
Number of the outlet in the PDU.
1.3.6.1.4.1.10418.26.2.5.5.1.3InterfaceIndexread-onlycurrent
acsPowerMgmtOutletsTableName
OBJECT-TYPE
Name of the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1.4DisplayStringread-onlycurrent
acsPowerMgmtOutletsTableStatus
OBJECT-TYPE
Status of the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1.5INTEGER {off(1), on(2)}read-onlycurrent
acsPowerMgmtOutletsTablePowerControl
OBJECT-TYPE
A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs
1.3.6.1.4.1.10418.26.2.5.5.1.6INTEGER {noAction(1), powerOn(2), powerOff(3), powerCycle(4), powerLock(5), powerUnlock(6)}read-writecurrent
acsPowerMgmtOutletsTablePortName
OBJECT-TYPE
Serial Port Name where the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.5.1.7DisplayStringread-onlycurrent
acsPowerMgmtOutletsTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.5.1.8DisplayStringread-onlycurrent
acsPowerMgmtNumberOfOutletGroup
OBJECT-TYPE
Number of configured group of outlets.
1.3.6.1.4.1.10418.26.2.5.6Integer32read-onlycurrent
acsPowerMgmtGroupTable
OBJECT-TYPE
This table contains the information about group of outlets.
1.3.6.1.4.1.10418.26.2.5.7not-accessiblecurrent
acsPowerMgmtGroupTableEntry
OBJECT-TYPE
each entry has the information about group of outlets.
1.3.6.1.4.1.10418.26.2.5.7.1not-accessiblecurrent
acsPowerMgmtGroupTableIndex
OBJECT-TYPE
Index of the group.
1.3.6.1.4.1.10418.26.2.5.7.1.1InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtGroupTableName
OBJECT-TYPE
Name of the group of outlets.
1.3.6.1.4.1.10418.26.2.5.7.1.2DisplayStringread-onlycurrent
acsPowerMgmtGroupTableStatus
OBJECT-TYPE
Status of the group of outlet.
1.3.6.1.4.1.10418.26.2.5.7.1.3INTEGER {off(1), on(2)}read-onlycurrent
acsPowerMgmtGroupTablePowerControl
OBJECT-TYPE
A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU.
1.3.6.1.4.1.10418.26.2.5.7.1.4INTEGER {noAction(1), powerOn(2), powerOff(3), powerCycle(4)}read-writecurrent
acsPowerMgmtPhasesTable
OBJECT-TYPE
This table contains data monitoring of each detected phase.
1.3.6.1.4.1.10418.26.2.5.8not-accessiblecurrent
acsPowerMgmtPhasesTableEntry
OBJECT-TYPE
each entry has the data monitoring about phases.
1.3.6.1.4.1.10418.26.2.5.8.1not-accessiblecurrent
acsPowerMgmtPhasesTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.8.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtPhasesTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.8.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtPhasesTablePhaseIndex
OBJECT-TYPE
phase index in the PDU.
1.3.6.1.4.1.10418.26.2.5.8.1.3InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtPhasesTablePhaseName
OBJECT-TYPE
phase name in the PDU.
1.3.6.1.4.1.10418.26.2.5.8.1.4DisplayStringread-onlycurrent
acsPowerMgmtPhasesTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.8.1.5DisplayStringread-onlycurrent
acsPowerMgmtPhasesTablePortName
OBJECT-TYPE
Name of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.8.1.6DisplayStringread-onlycurrent
acsPowerMgmtPhasesTableCurrentValue
OBJECT-TYPE
Actual value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.7Integer32read-onlycurrent
acsPowerMgmtPhasesTableCurrentMax
OBJECT-TYPE
Max detected value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.8Integer32read-onlycurrent
acsPowerMgmtPhasesTableCurrentMin
OBJECT-TYPE
Min detected value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.9Integer32read-onlycurrent
acsPowerMgmtPhasesTableCurrentAvg
OBJECT-TYPE
Average value for current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.10Integer32read-onlycurrent
acsPowerMgmtPhasesTableCurrentReset
OBJECT-TYPE
Reset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.8.1.11INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPhasesTableVoltageType
OBJECT-TYPE
Type of voltage values.
1.3.6.1.4.1.10418.26.2.5.8.1.12INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPhasesTableVoltageValue
OBJECT-TYPE
Actual value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.13Integer32read-onlycurrent
acsPowerMgmtPhasesTableVoltageMax
OBJECT-TYPE
Max detected value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.14Integer32read-onlycurrent
acsPowerMgmtPhasesTableVoltageMin
OBJECT-TYPE
Min detected value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.15Integer32read-onlycurrent
acsPowerMgmtPhasesTableVoltageAvg
OBJECT-TYPE
Average value for voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.16Integer32read-onlycurrent
acsPowerMgmtPhasesTableVoltageReset
OBJECT-TYPE
Reset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.8.1.17INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPhasesTablePowerType
OBJECT-TYPE
Type of power consumption values.
1.3.6.1.4.1.10418.26.2.5.8.1.18INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPhasesTablePowerValue
OBJECT-TYPE
Actual value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.19Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerMax
OBJECT-TYPE
Max detected value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.20Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerMin
OBJECT-TYPE
Min detected value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.21Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerAvg
OBJECT-TYPE
Average value for power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.22Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerReset
OBJECT-TYPE
Reset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.8.1.23INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPhasesTablePowerFactorType
OBJECT-TYPE
Type of power factor values.
1.3.6.1.4.1.10418.26.2.5.8.1.24INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtPhasesTablePowerFactorValue
OBJECT-TYPE
Actual value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.25Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerFactorMax
OBJECT-TYPE
Max detected value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.26Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerFactorMin
OBJECT-TYPE
Min detected value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.27Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerFactorAvg
OBJECT-TYPE
Average value for power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.28Integer32read-onlycurrent
acsPowerMgmtPhasesTablePowerFactorReset
OBJECT-TYPE
Reset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.8.1.29INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtPhasesTableAlarm
OBJECT-TYPE
Show the phase alarm status.
1.3.6.1.4.1.10418.26.2.5.8.1.30INTEGER {normal(1), blow-fuse(2), hw-ocp(3), high-critical(4), high-warning(5), low-warning(6), low-critical(7)}read-onlycurrent
acsPowerMgmtBanksTable
OBJECT-TYPE
This table contains data monitoring of each detected bank.
1.3.6.1.4.1.10418.26.2.5.9not-accessiblecurrent
acsPowerMgmtBanksTableEntry
OBJECT-TYPE
each entry has the data monitoring about bank.
1.3.6.1.4.1.10418.26.2.5.9.1not-accessiblecurrent
acsPowerMgmtBanksTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.9.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtBanksTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.9.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtBanksTableBankIndex
OBJECT-TYPE
Bank index in the PDU.
1.3.6.1.4.1.10418.26.2.5.9.1.3InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtBanksTableBankName
OBJECT-TYPE
Bank name in the PDU.
1.3.6.1.4.1.10418.26.2.5.9.1.4DisplayStringread-onlycurrent
acsPowerMgmtBanksTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.9.1.5DisplayStringread-onlycurrent
acsPowerMgmtBanksTablePortName
OBJECT-TYPE
Name of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.9.1.6DisplayStringread-onlycurrent
acsPowerMgmtBanksTableCurrentValue
OBJECT-TYPE
Actual value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.7Integer32read-onlycurrent
acsPowerMgmtBanksTableCurrentMax
OBJECT-TYPE
Max detected value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.8Integer32read-onlycurrent
acsPowerMgmtBanksTableCurrentMin
OBJECT-TYPE
Min detected value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.9Integer32read-onlycurrent
acsPowerMgmtBanksTableCurrentAvg
OBJECT-TYPE
Average value for current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.10Integer32read-onlycurrent
acsPowerMgmtBanksTableCurrentReset
OBJECT-TYPE
Reset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.9.1.11INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtBanksTableVoltageType
OBJECT-TYPE
Type of voltage values.
1.3.6.1.4.1.10418.26.2.5.9.1.12INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtBanksTableVoltageValue
OBJECT-TYPE
Actual value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.13Integer32read-onlycurrent
acsPowerMgmtBanksTableVoltageMax
OBJECT-TYPE
Max detected value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.14Integer32read-onlycurrent
acsPowerMgmtBanksTableVoltageMin
OBJECT-TYPE
Min detected value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.15Integer32read-onlycurrent
acsPowerMgmtBanksTableVoltageAvg
OBJECT-TYPE
Average value for voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.16Integer32read-onlycurrent
acsPowerMgmtBanksTableVoltageReset
OBJECT-TYPE
Reset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.9.1.17INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtBanksTablePowerType
OBJECT-TYPE
Type of power consumption values.
1.3.6.1.4.1.10418.26.2.5.9.1.18INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtBanksTablePowerValue
OBJECT-TYPE
Actual value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.19Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerMax
OBJECT-TYPE
Max detected value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.20Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerMin
OBJECT-TYPE
Min detected value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.21Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerAvg
OBJECT-TYPE
Average value for power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.22Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerReset
OBJECT-TYPE
Reset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.9.1.23INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtBanksTablePowerFactorType
OBJECT-TYPE
Type of power factor values.
1.3.6.1.4.1.10418.26.2.5.9.1.24INTEGER {none-sensor(0), estimated(1), read(2)}read-onlycurrent
acsPowerMgmtBanksTablePowerFactorValue
OBJECT-TYPE
Actual value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.25Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerFactorMax
OBJECT-TYPE
Max detected value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.26Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerFactorMin
OBJECT-TYPE
Min detected value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.27Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerFactorAvg
OBJECT-TYPE
Average value for power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.28Integer32read-onlycurrent
acsPowerMgmtBanksTablePowerFactorReset
OBJECT-TYPE
Reset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.9.1.29INTEGER {no-action(1), reset(2)}read-writecurrent
acsPowerMgmtBanksTableAlarm
OBJECT-TYPE
Show the bank alarm status.
1.3.6.1.4.1.10418.26.2.5.9.1.30INTEGER {normal(1), blow-fuse(2), hw-ocp(3), high-critical(4), high-warning(5), low-warning(6), low-critical(7)}read-onlycurrent
acsPowerMgmtEnvMonTable
OBJECT-TYPE
This table contains data monitoring of each detected environmental sensor.
1.3.6.1.4.1.10418.26.2.5.10not-accessiblecurrent
acsPowerMgmtEnvMonTableEntry
OBJECT-TYPE
each entry has the data monitoring about environmental sensors.
1.3.6.1.4.1.10418.26.2.5.10.1not-accessiblecurrent
acsPowerMgmtEnvMonTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.10.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtEnvMonTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.10.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtEnvMonTableIndex
OBJECT-TYPE
envmon sensor index.
1.3.6.1.4.1.10418.26.2.5.10.1.3InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtEnvMonTableName
OBJECT-TYPE
envmon sensor name.
1.3.6.1.4.1.10418.26.2.5.10.1.4DisplayStringread-onlycurrent
acsPowerMgmtEnvMonTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.10.1.5DisplayStringread-onlycurrent
acsPowerMgmtEnvMonTablePortName
OBJECT-TYPE
Name of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.10.1.6DisplayStringread-onlycurrent
acsPowerMgmtEnvMonTableType
OBJECT-TYPE
The type of environmental monitor.
1.3.6.1.4.1.10418.26.2.5.10.1.7INTEGER {temp-internal(1), temperature(2), humidity(3), air-flow(4), smoke(5), dry-contact(6), water-level(7), motion(8), unplugged(9), unknown(10), air-pressure(11), vibration(12), vibration-contact(13), leak(14), door-contact(15), dewpoint(16), ad-converter(17), voltage(18), current(19)}read-onlycurrent
acsPowerMgmtEnvMonTableStatus
OBJECT-TYPE
Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor, Door-Contact, Leak, A2D. For Door-Contact, normal(1) = closed, triggered(2) = opened. For A2D, normal(1) = low, triggered(2) = high. For Leak, normal(1) = no leak, leak(4) = leak, cableFault(5) = cable fault.
1.3.6.1.4.1.10418.26.2.5.10.1.8INTEGER {normal(1), triggered(2), not-applicable(3), leak(4), cableFault(5)}read-onlycurrent
acsPowerMgmtEnvMonTableValue
OBJECT-TYPE
Detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.
1.3.6.1.4.1.10418.26.2.5.10.1.9Integer32read-onlycurrent
acsPowerMgmtEnvMonTableMaxValue
OBJECT-TYPE
Max detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu. Voltage VDC x 100. Current x 100.
1.3.6.1.4.1.10418.26.2.5.10.1.10Integer32read-onlycurrent
acsPowerMgmtOutElecMonTable
OBJECT-TYPE
This table contains the information about data monitoring of outlets.
1.3.6.1.4.1.10418.26.2.5.11not-accessiblecurrent
acsPowerMgmtOutElecMonTableEntry
OBJECT-TYPE
each entry has the information about the outlet.
1.3.6.1.4.1.10418.26.2.5.11.1not-accessiblecurrent
acsPowerMgmtOutElecMonTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.11.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtOutElecMonTablePduNumber
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.11.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtOutElecMonTableNumber
OBJECT-TYPE
Number of the outlet in the PDU.
1.3.6.1.4.1.10418.26.2.5.11.1.3InterfaceIndexread-onlycurrent
acsPowerMgmtOutElecMonTableCurrentValue
OBJECT-TYPE
Actual value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.4Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableCurrentMax
OBJECT-TYPE
Max detected value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.5Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableCurrentMin
OBJECT-TYPE
Min detected value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.6Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableCurrentAvg
OBJECT-TYPE
Average value for outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.7Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableCurrentReset
OBJECT-TYPE
Reset max, min and avertage values of outlet current.
1.3.6.1.4.1.10418.26.2.5.11.1.8INTEGER {noAction(1), reset(2)}read-writecurrent
acsPowerMgmtOutElecMonTablePowerValue
OBJECT-TYPE
Actual value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.9Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerMax
OBJECT-TYPE
Max detected value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.10Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerMin
OBJECT-TYPE
Min detected value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.11Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerAvg
OBJECT-TYPE
Average value for outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.12Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerReset
OBJECT-TYPE
Reset max, min and avertage values of outlet power comsumption.
1.3.6.1.4.1.10418.26.2.5.11.1.13INTEGER {noAction(1), reset(2)}read-writecurrent
acsPowerMgmtOutElecMonTableVoltageValue
OBJECT-TYPE
Actual value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.14Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableVoltageMax
OBJECT-TYPE
Max detected value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.15Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableVoltageMin
OBJECT-TYPE
Min detected value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.16Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableVoltageAvg
OBJECT-TYPE
Average value for outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.17Integer32read-onlycurrent
acsPowerMgmtOutElecMonTableVoltageReset
OBJECT-TYPE
Reset max, min and avertage values of outlet voltage.
1.3.6.1.4.1.10418.26.2.5.11.1.18INTEGER {noAction(1), reset(2)}read-writecurrent
acsPowerMgmtOutElecMonTablePowerFactorValue
OBJECT-TYPE
Actual value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.19Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerFactorMax
OBJECT-TYPE
Max detected value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.20Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerFactorMin
OBJECT-TYPE
Min detected value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.21Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerFactorAvg
OBJECT-TYPE
Average value for outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.22Integer32read-onlycurrent
acsPowerMgmtOutElecMonTablePowerFactorReset
OBJECT-TYPE
Reset max, min and avertage values of outlet power-factor.
1.3.6.1.4.1.10418.26.2.5.11.1.23INTEGER {noAction(1), reset(2)}read-writecurrent
acsPowerMgmtOutElecMonTableAlarm
OBJECT-TYPE
Show the outlet alarm status.
1.3.6.1.4.1.10418.26.2.5.11.1.24INTEGER {normal(1), blow-fuse(2), hw-ocp(3), high-critical(4), high-warning(5), low-warning(6), low-critical(7)}read-onlycurrent
acsPowerMgmtUPSTable
OBJECT-TYPE
This table contains the list of detected UPSs.
1.3.6.1.4.1.10418.26.2.5.12not-accessiblecurrent
acsPowerMgmtUPSTableEntry
OBJECT-TYPE
Each entry has the information about the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1not-accessiblecurrent
acsPowerMgmtUPSTablePortNumber
OBJECT-TYPE
Number of serial port when the UPS is connected.
1.3.6.1.4.1.10418.26.2.5.12.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSTableUpsIndex
OBJECT-TYPE
A UPS position in the chain.
1.3.6.1.4.1.10418.26.2.5.12.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtUPSTableUpsId
OBJECT-TYPE
UPS identification.
1.3.6.1.4.1.10418.26.2.5.12.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSTablePortName
OBJECT-TYPE
Name of serial port or IP address if network device
1.3.6.1.4.1.10418.26.2.5.12.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSTableModel
OBJECT-TYPE
Model of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSTableVendor
OBJECT-TYPE
Vendor of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.6DisplayStringread-onlycurrent
acsPowerMgmtUPSTableFirmwareVersion
OBJECT-TYPE
Version of the UPS firmware.
1.3.6.1.4.1.10418.26.2.5.12.1.7DisplayStringread-onlycurrent
acsPowerMgmtUPSTableAgentFirmwareVersion
OBJECT-TYPE
Firmware version of the agent card.
1.3.6.1.4.1.10418.26.2.5.12.1.8DisplayStringread-onlycurrent
acsPowerMgmtUPSTableSystemStatus
OBJECT-TYPE
System Status of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.9DisplayStringread-onlycurrent
acsPowerMgmtUPSTableInputBlackOutCount
OBJECT-TYPE
The number of occurrences, since the last reset, where the input was not qualified to provide power to the system.
1.3.6.1.4.1.10418.26.2.5.12.1.10Integer32read-onlycurrent
acsPowerMgmtUPSTableInputBrownOutCount
OBJECT-TYPE
The number of occurrences, since the last reset, where the system input voltage has fallen below a pre-determined threshold for a specified amount of time.
1.3.6.1.4.1.10418.26.2.5.12.1.11Integer32read-onlycurrent
acsPowerMgmtUPSTableInletAirTemperature
OBJECT-TYPE
Temperature of the inlet air.
1.3.6.1.4.1.10418.26.2.5.12.1.12DisplayStringread-onlycurrent
acsPowerMgmtUPSTableNumberOutletGroups
OBJECT-TYPE
The number of Outlet Groups on this UPS
1.3.6.1.4.1.10418.26.2.5.12.1.13Integer32read-onlycurrent
acsPowerMgmtUPSTableUPSSerialNumber
OBJECT-TYPE
System serial number.
1.3.6.1.4.1.10418.26.2.5.12.1.14DisplayStringread-onlycurrent
acsPowerMgmtUPSTableUPSManufactureDate
OBJECT-TYPE
Manufacturing date of the system.
1.3.6.1.4.1.10418.26.2.5.12.1.15DisplayStringread-onlycurrent
acsPowerMgmtUPSTableAutoRestartDelay
OBJECT-TYPE
If power is lost, the control will delay this amount of time after power is restored before restarting the unit.
1.3.6.1.4.1.10418.26.2.5.12.1.16Integer32read-writecurrent
acsPowerMgmtUPSTableAutoRestartControl
OBJECT-TYPE
When set to enabled, the UPS will automatically restart the load when utility power is restored after a battery discharge.
1.3.6.1.4.1.10418.26.2.5.12.1.17INTEGER {disabled(1), enabled(2)}read-writecurrent
acsPowerMgmtUPSTableAudibleAlarmControl
OBJECT-TYPE
Audible alarm control.
1.3.6.1.4.1.10418.26.2.5.12.1.18INTEGER {off(1), on(2)}read-writecurrent
acsPowerMgmtUPSTableSilenceAlarm
OBJECT-TYPE
Silence audible alarm.
1.3.6.1.4.1.10418.26.2.5.12.1.19INTEGER {noAction(0), silenceAlarm(1)}read-writecurrent
acsPowerMgmtUPSTableInverterState
OBJECT-TYPE
Inverter on/off state.
1.3.6.1.4.1.10418.26.2.5.12.1.20DisplayStringread-onlycurrent
acsPowerMgmtUPSTableDCConverterStatus
OBJECT-TYPE
The operating state of the dc converter.
1.3.6.1.4.1.10418.26.2.5.12.1.21DisplayStringread-onlycurrent
acsPowerMgmtUPSTableShutdownReason
OBJECT-TYPE
The reason for the most recent shutdown.
1.3.6.1.4.1.10418.26.2.5.12.1.22DisplayStringread-onlycurrent
acsPowerMgmtUPSTableUPSTopology
OBJECT-TYPE
UPS Topology.
1.3.6.1.4.1.10418.26.2.5.12.1.23DisplayStringread-onlycurrent
acsPowerMgmtUPSTableBypassInverterInputConfig
OBJECT-TYPE
Input source configuration for the bypass and inverter.
1.3.6.1.4.1.10418.26.2.5.12.1.24DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTable
OBJECT-TYPE
This table contains the information about UPS inputs.
1.3.6.1.4.1.10418.26.2.5.13not-accessiblecurrent
acsPowerMgmtUPSInputTableEntry
OBJECT-TYPE
each entry has the information about the UPS inputs.
1.3.6.1.4.1.10418.26.2.5.13.1not-accessiblecurrent
acsPowerMgmtUPSInputTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.13.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSInputTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.13.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSInputTableFrequency
OBJECT-TYPE
Input Frequency.
1.3.6.1.4.1.10418.26.2.5.13.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableRMSVoltageL1N
OBJECT-TYPE
RMS Voltage L1-N.
1.3.6.1.4.1.10418.26.2.5.13.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableRMSVoltageL1L2
OBJECT-TYPE
RMS Voltage L1L2.
1.3.6.1.4.1.10418.26.2.5.13.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableRMSVoltageL2N
OBJECT-TYPE
RMS Voltage L2N.
1.3.6.1.4.1.10418.26.2.5.13.1.6DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableRMSCurrentL1
OBJECT-TYPE
RMS Current for L1.
1.3.6.1.4.1.10418.26.2.5.13.1.7DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableRMSCurrentL2
OBJECT-TYPE
RMS Current for L2.
1.3.6.1.4.1.10418.26.2.5.13.1.8DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableMaxVoltageL1N
OBJECT-TYPE
Input Max Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.9DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableMinVoltageL1N
OBJECT-TYPE
Input Min Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.10DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableMaxVoltageL2N
OBJECT-TYPE
Input Max Voltage measurement for Line L2-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.11DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableMinVoltageL2N
OBJECT-TYPE
Input Min Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.12DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableNominalVoltage
OBJECT-TYPE
Input nominal voltage.
1.3.6.1.4.1.10418.26.2.5.13.1.13DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableNominalFrequency
OBJECT-TYPE
Input nominal frequency.
1.3.6.1.4.1.10418.26.2.5.13.1.14DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableNominalCurrent
OBJECT-TYPE
Input nominal current.
1.3.6.1.4.1.10418.26.2.5.13.1.15DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTableEnergy
OBJECT-TYPE
Input Energy.
1.3.6.1.4.1.10418.26.2.5.13.1.16DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTablePowerFactorL1N
OBJECT-TYPE
Input Power Factor for Line 1.
1.3.6.1.4.1.10418.26.2.5.13.1.17DisplayStringread-onlycurrent
acsPowerMgmtUPSInputTablePowerFactorL2N
OBJECT-TYPE
Input Power Factor for Line 2.
1.3.6.1.4.1.10418.26.2.5.13.1.18DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTable
OBJECT-TYPE
This table contains the information about UPS bypass.
1.3.6.1.4.1.10418.26.2.5.14not-accessiblecurrent
acsPowerMgmtUPSBypassTableEntry
OBJECT-TYPE
each entry has the information about the UPS bypass.
1.3.6.1.4.1.10418.26.2.5.14.1not-accessiblecurrent
acsPowerMgmtUPSBypassTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.14.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSBypassTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.14.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSBypassTableRMSVoltageL1N
OBJECT-TYPE
RMS Voltage L1N.
1.3.6.1.4.1.10418.26.2.5.14.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableRMSVoltageL1L2
OBJECT-TYPE
RMS Voltage L1L2.
1.3.6.1.4.1.10418.26.2.5.14.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableRMSVoltageL2N
OBJECT-TYPE
RMS Voltage L2N.
1.3.6.1.4.1.10418.26.2.5.14.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableRMSCurrent
OBJECT-TYPE
RMS Current.
1.3.6.1.4.1.10418.26.2.5.14.1.6DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableRMSCurrentL2
OBJECT-TYPE
RMS Current.
1.3.6.1.4.1.10418.26.2.5.14.1.7DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableInputFrequency
OBJECT-TYPE
Bypass Input Frequency.
1.3.6.1.4.1.10418.26.2.5.14.1.8DisplayStringread-onlycurrent
acsPowerMgmtUPSBypassTableNominalVoltage
OBJECT-TYPE
Bypass Nominal Voltage.
1.3.6.1.4.1.10418.26.2.5.14.1.9DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTable
OBJECT-TYPE
This table contains the information about UPS battery.
1.3.6.1.4.1.10418.26.2.5.15not-accessiblecurrent
acsPowerMgmtUPSBatteryTableEntry
OBJECT-TYPE
each entry has the information about the UPS bypass.
1.3.6.1.4.1.10418.26.2.5.15.1not-accessiblecurrent
acsPowerMgmtUPSBatteryTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.15.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSBatteryTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.15.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSBatteryTableDCBusVoltage
OBJECT-TYPE
DC Bus Voltage
1.3.6.1.4.1.10418.26.2.5.15.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableTimeRemaining
OBJECT-TYPE
The calculated available time on battery.
1.3.6.1.4.1.10418.26.2.5.15.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTablePercentageCharge
OBJECT-TYPE
Battery Percentage Charge.
1.3.6.1.4.1.10418.26.2.5.15.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableChargeStatus
OBJECT-TYPE
Battery Charge Status.
1.3.6.1.4.1.10418.26.2.5.15.1.6DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableLowBatteryWarningTime
OBJECT-TYPE
When battery time remaining falls to, or below, this value (minutes) the low battery alarm is activated.
1.3.6.1.4.1.10418.26.2.5.15.1.7INTEGER (2..30)read-writecurrent
acsPowerMgmtUPSBatteryTableTestResult
OBJECT-TYPE
The outcome of the previous battery test.
1.3.6.1.4.1.10418.26.2.5.15.1.8DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableDCBusNominalVoltage
OBJECT-TYPE
Battery DC Bus Nominal Voltage.
1.3.6.1.4.1.10418.26.2.5.15.1.9DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableNominalBatteryCapacity
OBJECT-TYPE
Nominal Battery Capacity.
1.3.6.1.4.1.10418.26.2.5.15.1.10DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryFloatVoltage
OBJECT-TYPE
Battery Float Voltage.
1.3.6.1.4.1.10418.26.2.5.15.1.11DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryCabinetType
OBJECT-TYPE
Battery Cabinet Type.
1.3.6.1.4.1.10418.26.2.5.15.1.12DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryNumberOfEBC
OBJECT-TYPE
Number of Extended Battery Cabinets installed.
1.3.6.1.4.1.10418.26.2.5.15.1.13DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryRating
OBJECT-TYPE
Battery Rating.
1.3.6.1.4.1.10418.26.2.5.15.1.14DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryDischargeTime
OBJECT-TYPE
Time on battery operation for this discharge
1.3.6.1.4.1.10418.26.2.5.15.1.15DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryChargeCompensating
OBJECT-TYPE
Battery charge algorithm changed due to battery temperature.
1.3.6.1.4.1.10418.26.2.5.15.1.16DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryChargerState
OBJECT-TYPE
Battery charger state.
1.3.6.1.4.1.10418.26.2.5.15.1.17DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableStartBatteryTest
OBJECT-TYPE
Command to initate a manual battery test.
1.3.6.1.4.1.10418.26.2.5.15.1.18INTEGER {noAction(1), start(2)}read-writecurrent
acsPowerMgmtUPSBatteryTableBatteryStatus
OBJECT-TYPE
Battery Status.
1.3.6.1.4.1.10418.26.2.5.15.1.19DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryTotalDischargeTime
OBJECT-TYPE
Cumulative battery discharge time.
1.3.6.1.4.1.10418.26.2.5.15.1.20DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryDischargeCount
OBJECT-TYPE
Total number of battery discharges.
1.3.6.1.4.1.10418.26.2.5.15.1.21DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableBatteryCurrent
OBJECT-TYPE
Current at the battery input terminals. In charging mode, the current will be a positive value. In discharging mode, the current will be a negative value.
1.3.6.1.4.1.10418.26.2.5.15.1.22DisplayStringread-onlycurrent
acsPowerMgmtUPSBatteryTableAutomaticBatteryTest
OBJECT-TYPE
Automatic Battery Test
1.3.6.1.4.1.10418.26.2.5.15.1.23DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTable
OBJECT-TYPE
This table contains the information about UPS output.
1.3.6.1.4.1.10418.26.2.5.16not-accessiblecurrent
acsPowerMgmtUPSOutputTableEntry
OBJECT-TYPE
Each entry has the information about the UPS output.
1.3.6.1.4.1.10418.26.2.5.16.1not-accessiblecurrent
acsPowerMgmtUPSOutputTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.16.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSOutputTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.16.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSOutputTableApparentPower
OBJECT-TYPE
DC Bus Voltage
1.3.6.1.4.1.10418.26.2.5.16.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableFrequency
OBJECT-TYPE
Output frequency.
1.3.6.1.4.1.10418.26.2.5.16.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePercentPower
OBJECT-TYPE
The system output power as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePercentPowerL1
OBJECT-TYPE
The system output power on line L1 as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.6DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePercentPowerL2
OBJECT-TYPE
The system output power on line L2 as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.7DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePower
OBJECT-TYPE
The sum total power of all system output phases.
1.3.6.1.4.1.10418.26.2.5.16.1.8DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableRMSCurrentL1
OBJECT-TYPE
System output RMS current for line L1.
1.3.6.1.4.1.10418.26.2.5.16.1.9DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableRMSCurrentL2
OBJECT-TYPE
System output RMS current for line L2.
1.3.6.1.4.1.10418.26.2.5.16.1.10DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableRMSVoltageL1N
OBJECT-TYPE
The system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.11DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableRMSVoltageL2N
OBJECT-TYPE
The system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.12DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableRMSVoltageL1L2
OBJECT-TYPE
The system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.13DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputOffDelay
OBJECT-TYPE
Turns the UPS output off after the number of seconds specified. When a value is written to this object the output will be turned off after the specified time has elapsed and the output will remain off.
1.3.6.1.4.1.10418.26.2.5.16.1.14INTEGER (0..300)read-writecurrent
acsPowerMgmtUPSOutputOnDelay
OBJECT-TYPE
Turns the UPS output on after the number of seconds specified. When a value is written to this object the output will be turned on after the specified time has elapsed.
1.3.6.1.4.1.10418.26.2.5.16.1.15INTEGER (0..300)read-writecurrent
acsPowerMgmtUPSOutputCycleDelay
OBJECT-TYPE
Turns the UPS off and then back on after the number of seconds specified. When a value is written to this object the output will turned off immediately and then turned back on after the specified time has elapsed.
1.3.6.1.4.1.10418.26.2.5.16.1.16INTEGER (0..300)read-writecurrent
acsPowerMgmtUPSOutputTableMaxVoltageL1
OBJECT-TYPE
The maximum system output voltage measurement for line 1 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.17DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableMinVoltageL1
OBJECT-TYPE
The minimum system output voltage measurement for line 1 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.18DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableMaxVoltageL2
OBJECT-TYPE
The maximum system output voltage measurement for line 21 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.19DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableMinVoltageL2
OBJECT-TYPE
The minimum system output voltage measurement for line 2 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.20DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableNominalVoltage
OBJECT-TYPE
The nominal (or rated) system output voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.21DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerNominalFrequency
OBJECT-TYPE
The nominal (or rated) system output frequency.
1.3.6.1.4.1.10418.26.2.5.16.1.22DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerApparentPowerRating
OBJECT-TYPE
Output apparent power rating.
1.3.6.1.4.1.10418.26.2.5.16.1.23DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerNominalPowerFactor
OBJECT-TYPE
The nominal (or rated) system power factor.
1.3.6.1.4.1.10418.26.2.5.16.1.24DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerPowerFactorCorrection
OBJECT-TYPE
The state of the power factor correction circuitry of the system.
1.3.6.1.4.1.10418.26.2.5.16.1.25DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerL1
OBJECT-TYPE
The system output power on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.26DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerL2
OBJECT-TYPE
The system output power on line 2.
1.3.6.1.4.1.10418.26.2.5.16.1.27DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableApparentPowerL1
OBJECT-TYPE
The system output apparent power on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.28DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTableApparentPowerL2
OBJECT-TYPE
The system output apparent power on line 2.
1.3.6.1.4.1.10418.26.2.5.16.1.29DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerFactorL1
OBJECT-TYPE
The system output power factor on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.30DisplayStringread-onlycurrent
acsPowerMgmtUPSOutputTablePowerFactorL2
OBJECT-TYPE
The system output power factor on line 2.
1.3.6.1.4.1.10418.26.2.5.16.1.31DisplayStringread-onlycurrent
acsPowerMgmtUPSEcoModeTable
OBJECT-TYPE
This table contains the information about UPS ECO Mode.
1.3.6.1.4.1.10418.26.2.5.17not-accessiblecurrent
acsPowerMgmtUPSEcoModeTableEntry
OBJECT-TYPE
each entry has the information about the UPS ECO Mode.
1.3.6.1.4.1.10418.26.2.5.17.1not-accessiblecurrent
acsPowerMgmtUPSEcoModeTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.17.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSEcoModeTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.17.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSEcoModeTableStatus
OBJECT-TYPE
Current ECO Mode Status.
1.3.6.1.4.1.10418.26.2.5.17.1.3DisplayStringread-onlycurrent
acsPowerMgmtUPSEcoModeTableStateControl
OBJECT-TYPE
Enable or disable ECO mode.
1.3.6.1.4.1.10418.26.2.5.17.1.4INTEGER {noAction(1), enable(2), disable(3)}read-writecurrent
acsPowerMgmtUPSOutletGroupTable
OBJECT-TYPE
This table contains the UPS Outlet Group Information.
1.3.6.1.4.1.10418.26.2.5.18not-accessiblecurrent
acsPowerMgmtUPSOutletGroupTableEntry
OBJECT-TYPE
Each entry has the UPS outlet group information.
1.3.6.1.4.1.10418.26.2.5.18.1not-accessiblecurrent
acsPowerMgmtUPSOutletGroupTablePortNumber
OBJECT-TYPE
Serial Port number.
1.3.6.1.4.1.10418.26.2.5.18.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtUPSOutletGroupTableUpsIndex
OBJECT-TYPE
Index.
1.3.6.1.4.1.10418.26.2.5.18.1.2InterfaceIndexread-onlycurrent
acsPowerMgmtUPSOutletGroupTableNumber
OBJECT-TYPE
Number of the outletgroup in the UPS.
1.3.6.1.4.1.10418.26.2.5.18.1.3InterfaceIndexread-onlycurrent
acsPowerMgmtUPSOutletGroupTableLabel
OBJECT-TYPE
User-defined label for the outlet group.
1.3.6.1.4.1.10418.26.2.5.18.1.4DisplayStringread-onlycurrent
acsPowerMgmtUPSOutletGroupTableState
OBJECT-TYPE
User-defined label for the outlet group.
1.3.6.1.4.1.10418.26.2.5.18.1.5DisplayStringread-onlycurrent
acsPowerMgmtUPSOutletGroupTablePowerControl
OBJECT-TYPE
A set value of power(2-6) will send command to the UPS. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to UPS. powerOff(3) = when SET the power Off command is sent to UPS. powerCycle(4)=when SET the power cycle command is sent to UPS.
1.3.6.1.4.1.10418.26.2.5.18.1.6INTEGER {noAction(1), powerOn(2), powerOff(3), powerCycle(4)}read-writecurrent
acsPowerMgmtInletsTable
OBJECT-TYPE
This table contains data monitoring of each detected inlet.
1.3.6.1.4.1.10418.26.2.5.19not-accessiblecurrent
acsPowerMgmtInletsTableEntry
OBJECT-TYPE
each entry has the data monitoring about inlets.
1.3.6.1.4.1.10418.26.2.5.19.1not-accessiblecurrent
acsPowerMgmtInletsTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.19.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtInletsTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.19.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtInletsTableInletIndex
OBJECT-TYPE
inlet index in the PDU.
1.3.6.1.4.1.10418.26.2.5.19.1.3InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtInletsTableInletName
OBJECT-TYPE
inlet name in the PDU.
1.3.6.1.4.1.10418.26.2.5.19.1.4DisplayStringread-onlycurrent
acsPowerMgmtInletsTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.19.1.5DisplayStringread-onlycurrent
acsPowerMgmtInletsTablePortName
OBJECT-TYPE
Name of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.19.1.6DisplayStringread-onlycurrent
acsPowerMgmtInletsTableCurrentValue
OBJECT-TYPE
Actual value of current sensor in this inlet.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.19.1.7Integer32read-onlycurrent
acsPowerMgmtInletsTableVoltageValue
OBJECT-TYPE
Actual value of voltage sensor in this inlet.( V )
1.3.6.1.4.1.10418.26.2.5.19.1.8Integer32read-onlycurrent
acsPowerMgmtInletsTableVoltageCrestFactor
OBJECT-TYPE
Voltage crest factor x 10
1.3.6.1.4.1.10418.26.2.5.19.1.9Integer32read-onlycurrent
acsPowerMgmtInletsTableCurrentCrestFactor
OBJECT-TYPE
Current crest factor x 10
1.3.6.1.4.1.10418.26.2.5.19.1.10Integer32read-onlycurrent
acsPowerMgmtInletsTableFrequency
OBJECT-TYPE
Transfer switch source frequency (H x 10)
1.3.6.1.4.1.10418.26.2.5.19.1.11Integer32read-onlycurrent
acsPowerMgmtInletsTableSourceStatus
OBJECT-TYPE
Power source status
1.3.6.1.4.1.10418.26.2.5.19.1.12INTEGER {unknown(0), qualified(1), notQualified(2)}read-onlycurrent
acsPowerMgmtInletsTableSourceState
OBJECT-TYPE
Power source state
1.3.6.1.4.1.10418.26.2.5.19.1.13INTEGER {unknown(0), on(1), off(2)}read-onlycurrent
acsPowerMgmtInletsTableAlarm
OBJECT-TYPE
Show the inlet alarm status.
1.3.6.1.4.1.10418.26.2.5.19.1.14INTEGER {normal(1), blow-fuse(2), hw-ocp(3), high-critical(4), high-warning(5), low-warning(6), low-critical(7), source-alarm(8)}read-onlycurrent
acsPowerMgmtTransferTable
OBJECT-TYPE
This table contains data monitoring for a transfer switch.
1.3.6.1.4.1.10418.26.2.5.20not-accessiblecurrent
acsPowerMgmtTransferTableEntry
OBJECT-TYPE
Transfer switch data for devices which support this feature.
1.3.6.1.4.1.10418.26.2.5.20.1not-accessiblecurrent
acsPowerMgmtTransferTablePortNumber
OBJECT-TYPE
Number of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.20.1.1InterfaceIndexread-onlycurrent
acsPowerMgmtTransferTablePduIndex
OBJECT-TYPE
A PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.20.1.2InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtTransferTableTransferIndex
OBJECT-TYPE
transfer index in the PDU.
1.3.6.1.4.1.10418.26.2.5.20.1.3InterfaceIndexOrZeroread-onlycurrent
acsPowerMgmtTransferTablePduId
OBJECT-TYPE
PDU identification.
1.3.6.1.4.1.10418.26.2.5.20.1.4DisplayStringread-onlycurrent
acsPowerMgmtTransferTablePortName
OBJECT-TYPE
Name of serial port where the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.20.1.5DisplayStringread-onlycurrent
acsPowerMgmtTransferTableRetransferEnabled
OBJECT-TYPE
Enable/disable the auto-retransfer feature
1.3.6.1.4.1.10418.26.2.5.20.1.6INTEGER {unknown(0), disabled(1), enabled(2)}read-writecurrent
acsPowerMgmtTransferTableRetransferDelay
OBJECT-TYPE
Configures the delay before an auto-retransfer occurs, in seconds.
1.3.6.1.4.1.10418.26.2.5.20.1.7Integer32 (10..360)read-writecurrent
acsPowerMgmtTransferTablePreferredSource
OBJECT-TYPE
Configures the preferred source for the transfer switch.
1.3.6.1.4.1.10418.26.2.5.20.1.8INTEGER {unknown(0), sourceA(1), sourceB(2)}read-writecurrent
acsPowerMgmtTransferTableHealthTestEnabled
OBJECT-TYPE
Enable/disable the auto health test feature.
1.3.6.1.4.1.10418.26.2.5.20.1.9INTEGER {unknown(0), disabled(1), enabled(2)}read-writecurrent
acsPowerMgmtTransferTableHealthTestPeriod
OBJECT-TYPE
Configures the number of days to wait between health tests.
1.3.6.1.4.1.10418.26.2.5.20.1.10Integer32 (1..365)read-writecurrent
acsPowerMgmtTransferTableTransferLastTime
OBJECT-TYPE
Date and time when the last transfer ocurred.
1.3.6.1.4.1.10418.26.2.5.20.1.11DisplayStringread-onlycurrent
acsPowerMgmtTransferTableTransferCount
OBJECT-TYPE
Number of times a transfer has occurred.
1.3.6.1.4.1.10418.26.2.5.20.1.12Integer32read-onlycurrent
acsPowerMgmtTransferTableHardwareFault
OBJECT-TYPE
Value will be true(1) if a hardware fault is detected.
1.3.6.1.4.1.10418.26.2.5.20.1.13INTEGER {unknown(0), true(1), false(2)}read-onlycurrent
acsPowerMgmtTransferTablePowerOutputEnabled
OBJECT-TYPE
Value will be true(1) if power output is enabled.
1.3.6.1.4.1.10418.26.2.5.20.1.14INTEGER {unknown(0), true(1), false(2)}read-onlycurrent
acsTrapObject
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.6
acsSensors
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.7
acsSensorsInternalCurrentCPUTemperature
OBJECT-TYPE
The current CPU temperature in degrees Celsius.
1.3.6.1.4.1.10418.26.2.7.1Integer32read-onlycurrent
acsSensorsInternalMaxCPUTemperature
OBJECT-TYPE
The CPU temperature in degrees Celsius that, if exceeded, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.2Integer32read-writecurrent
acsSensorsInternalMaxCPUTemperatureThreshold
OBJECT-TYPE
The CPU temperature threshold in degrees Celsius below the maximum CPU temperature. When the temperature exceeds the Maximum Temperature plus Threshold, an event notification will be generated. When the temperature falls below the Maximum Temperature minus Threshold, an event notification that the console system has returned to normal operating temperature will be generated.
1.3.6.1.4.1.10418.26.2.7.3Integer32 (0..4)read-writecurrent
acsSensorsInternalMinCPUTemperature
OBJECT-TYPE
The CPU temperature in degrees Celsius that, if the CPU temperature falls below, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.4Integer32read-writecurrent
acsSensorsInternalMinCPUTemperatureThreshold
OBJECT-TYPE
The CPU temperature threshold in degrees Celsius above the minimum CPU temperature.
1.3.6.1.4.1.10418.26.2.7.5Integer32 (0..4)read-writecurrent
acsSensorsInternalCurrentBoardTemperature
OBJECT-TYPE
The current board temperature in degrees Celsius.
1.3.6.1.4.1.10418.26.2.7.6Integer32read-onlycurrent
acsSensorsInternalMaxBoardTemperature
OBJECT-TYPE
The board temperature in degrees Celsius that, if exceeded, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.7Integer32read-writecurrent
acsSensorsInternalMaxBoardTemperatureThreshold
OBJECT-TYPE
The board temperature threshold in degrees Celsius below the maximum board temperature. When the temperature exceeds the Maximum Temperature plus Threshold, an event notification will be generated. When the temperature falls below the Maximum Temperature minus Threshold, an event notification that the console system has returned to normal operating temperature will be generated.
1.3.6.1.4.1.10418.26.2.7.8Integer32 (0..4)read-writecurrent
acsSensorsInternalMinBoardTemperature
OBJECT-TYPE
The board temperature in degrees Celsius that, if the board temperature falls below, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.9Integer32read-writecurrent
acsSensorsInternalMinBoardTemperatureThreshold
OBJECT-TYPE
The board temperature threshold in degrees Celsius above the minimum board temperature.
1.3.6.1.4.1.10418.26.2.7.10Integer32 (0..4)read-writecurrent
acsSensorsVoltagePSInternal
OBJECT-TYPE
The PS Internal Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.11Integer32read-onlycurrent
acsSensorsVoltagePLInternal
OBJECT-TYPE
The PL Internal Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.12Integer32read-onlycurrent
acsSensorsVoltagePSAuxiliary
OBJECT-TYPE
The PS Auxiliary Supply voltage [1.71v ~ 1.89v] x 100.
1.3.6.1.4.1.10418.26.2.7.13Integer32read-onlycurrent
acsSensorsVoltagePLAuxiliary
OBJECT-TYPE
The PL Auxiliary Supply voltage [1.71v ~ 1.89v] x 100.
1.3.6.1.4.1.10418.26.2.7.14Integer32read-onlycurrent
acsSensorsVoltagePSDDR3
OBJECT-TYPE
The PS DDR3 Supply voltage [1.31v ~ 1.39v] x 100.
1.3.6.1.4.1.10418.26.2.7.15Integer32read-onlycurrent
acsSensorsVoltagePLBlockRam
OBJECT-TYPE
The PL Block RAM Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.16Integer32read-onlycurrent
acsSensorsVoltagePowerSupply1
OBJECT-TYPE
The Power Supply 1 voltage [11.06v ~ 12.98v] x 100.
1.3.6.1.4.1.10418.26.2.7.17Integer32read-onlycurrent
acsSensorsVoltagePowerSupply2
OBJECT-TYPE
The Power Supply 2 voltage [11.06v ~ 12.98v] x 100.
1.3.6.1.4.1.10418.26.2.7.18Integer32read-onlycurrent
acsSensors1WireUpdateControl
OBJECT-TYPE
A set value of update(2) will refresh the 1-wire sensor list.
1.3.6.1.4.1.10418.26.2.7.19INTEGER {noAction(1), update(2)}read-writecurrent
acsSensors1WireTable
OBJECT-TYPE
This table contains the list of detected external 1-wire sensors.
1.3.6.1.4.1.10418.26.2.7.20not-accessiblecurrent
acsSensors1WireTableEntry
OBJECT-TYPE
Each entry has the information about the external 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1not-accessiblecurrent
acsSensors1WireTableIndex
OBJECT-TYPE
Index of detected 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.1Integer32 (1..20)read-onlycurrent
acsSensors1WireTableName
OBJECT-TYPE
Name of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.2DisplayStringread-writecurrent
acsSensors1WireTableLocation
OBJECT-TYPE
Location of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.3DisplayStringread-writecurrent
acsSensors1WireTableAddress
OBJECT-TYPE
Address of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.4DisplayStringread-onlycurrent
acsSensors1WireTableType
OBJECT-TYPE
Type of 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.5INTEGER {sensor-unknown(0), external-temperature(1), external-humidity(2), door-contact(3), dry-contact(4), leak(5), differential-pressure(6)}read-onlycurrent
acsSensors1WireTableUnit
OBJECT-TYPE
The unit of the 1-wire sensor. notApplicable(0) = used for contact or leak sensor celsius(1) = used for temperature sensor fahrenheit(2) = used for temperature sensor percent(3) = used for humidity sensor pascal(4) = used for differential pressure sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.6INTEGER {notApplicable(0), celsius(1), fahrenheit(2), percent(3), pa(4)}read-onlycurrent
acsSensors1WireTableValue
OBJECT-TYPE
Current sensor reading.
1.3.6.1.4.1.10418.26.2.7.20.1.7DisplayStringread-onlycurrent
acsSensors1WireTableValueMax
OBJECT-TYPE
Maximum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.8Integer32read-onlycurrent
acsSensors1WireTableValueMin
OBJECT-TYPE
Minimum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.9Integer32read-onlycurrent
acsSensors1WireTableValueAvg
OBJECT-TYPE
Average sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.10Integer32read-onlycurrent
acsSensors1WireTableValueLowWarning
OBJECT-TYPE
If the sensor value falls below this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.11Integer32read-onlycurrent
acsSensors1WireTableValueLowCritical
OBJECT-TYPE
If the sensor value falls below this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.12Integer32read-writecurrent
acsSensors1WireTableValueHighWarning
OBJECT-TYPE
If the sensor value rises above this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.13Integer32read-writecurrent
acsSensors1WireTableValueHighCritical
OBJECT-TYPE
If the sensor value rises above this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.14Integer32read-writecurrent
acsSensors1WireTableReset
OBJECT-TYPE
A set value of update(2) will reset the 1-wire sensor min/max/avg values.
1.3.6.1.4.1.10418.26.2.7.20.1.15INTEGER {noAction(1), reset(2)}read-writecurrent
acsSensors1WireTableAnalogAlarm
OBJECT-TYPE
Status of the 1-wire analog sensor alarm. Used for temperature, humidity, and differential pressure sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.16INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsSensors1WireTableContactAlarm1
OBJECT-TYPE
Status of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.17INTEGER {notApplicable(0), disabled(1), alarmWhenOpen(2), alarmWhenClosed(3)}read-writecurrent
acsSensors1WireTableContactAlarm2
OBJECT-TYPE
Status of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.18INTEGER {notApplicable(0), disabled(1), alarmWhenOpen(2), alarmWhenClosed(3)}read-writecurrent
acsSensors1WireTableContactAlarm3
OBJECT-TYPE
Status of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.19INTEGER {notApplicable(0), disabled(1), alarmWhenOpen(2), alarmWhenClosed(3)}read-writecurrent
acsSensors1WireTableLeakFilterTime
OBJECT-TYPE
Leak filter time in seconds.
1.3.6.1.4.1.10418.26.2.7.20.1.20INTEGER {notApplicable(0), filter-time-15(1), filter-time-30(2), filter-time-60(3), filter-time-120(4)}read-writecurrent
acsSensors1WireTableLeakAlarm
OBJECT-TYPE
Status of the leak alarm for the leak sensor. Used for leak sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.21INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsSensors1WireTableLeakCableFailAlarm
OBJECT-TYPE
Status of the cable fail alarm for the leak sensor. Used for leak sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.22INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsSensorsDigitalInTable
OBJECT-TYPE
This table contains the list of Digital In sensors.
1.3.6.1.4.1.10418.26.2.7.21not-accessiblecurrent
acsSensorsDigitalInTableEntry
OBJECT-TYPE
Each entry has the information about the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1not-accessiblecurrent
acsSensorsDigitalInTablePosition
OBJECT-TYPE
Position of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.1Integer32 (1..4)read-onlycurrent
acsSensorsDigitalInTableName
OBJECT-TYPE
Name of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.2DisplayStringread-writecurrent
acsSensorsDigitalInTableLocation
OBJECT-TYPE
Location of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.3DisplayStringread-writecurrent
acsSensorsDigitalInTableType
OBJECT-TYPE
Configurable type of Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.4INTEGER {custom(0), vibration(1), smoke-ad-s(2), leak-sn-l(3), door(4), motion-ad-im(5)}read-writecurrent
acsSensorsDigitalInTableValue
OBJECT-TYPE
Value of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.5INTEGER {undefined(0), open(1), closed(2)}read-onlycurrent
acsSensorsDigitalInTableAlarm
OBJECT-TYPE
Status of the Digital In sensor alarm.
1.3.6.1.4.1.10418.26.2.7.21.1.6INTEGER {disabled(1), alarmWhenOpen(2), alarmWhenClosed(3)}read-writecurrent
acsModems
OBJECT-IDENTITY
1.3.6.1.4.1.10418.26.2.8
acsModemsNumberOfModems
OBJECT-TYPE
Number of modems, including auxiliary port built-in modems, pluggable USB modems, and serial port modems.
1.3.6.1.4.1.10418.26.2.8.1Integer32 (0..64)read-onlycurrent
acsModemsTable
OBJECT-TYPE
This table contains information about the ACS modems, including auxiliary port built-in modem, pluggable USB modems, and serial port modems.
1.3.6.1.4.1.10418.26.2.8.2not-accessiblecurrent
acsModemsTableEntry
OBJECT-TYPE
Each entry has the information about a specific modem.
1.3.6.1.4.1.10418.26.2.8.2.1not-accessiblecurrent
acsModemsTableNumber
OBJECT-TYPE
A unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.8.2.1.1Integer32 (1..49)read-onlycurrent
acsModemsTableDeviceName
OBJECT-TYPE
The associated device name for the modem.
1.3.6.1.4.1.10418.26.2.8.2.1.2DisplayString (SIZE(0..25))read-onlycurrent
acsModemsTableStatus
OBJECT-TYPE
Enables or disbles the modem.
1.3.6.1.4.1.10418.26.2.8.2.1.3INTEGER {disabled(1), enabled(2)}read-writecurrent
acsModemsTableProfile
OBJECT-TYPE
The modem profile. For an integrated cell modem, only dial-out(3) is valid.
1.3.6.1.4.1.10418.26.2.8.2.1.4INTEGER {unconfigured(1), dialIn(2), dialOut(3)}read-writecurrent
acsModemsTablePhoneNumber
OBJECT-TYPE
The dial-out phone number. Only supported if acsModemsTableProfile is set to dial-out(3). Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.5DisplayString (SIZE(0..25))read-writecurrent
acsModemsTableComSpeed
OBJECT-TYPE
The modem speed. Speeds above 230400 not supported by serial port modems.
1.3.6.1.4.1.10418.26.2.8.2.1.6INTEGER {speed1200(1200), speed2400(2400), speed4800(4800), speed9600(9600), speed19200(19200), speed38400(38400), speed57600(57600), speed115200(115200), speed230400(230400), speed460800(460800), speed921600(921600)}read-writecurrent
acsModemsTableInitChat
OBJECT-TYPE
Modem initialization string.
1.3.6.1.4.1.10418.26.2.8.2.1.7DisplayString (SIZE(0..1200))read-writecurrent
acsModemsTablePppAddressConfig
OBJECT-TYPE
Supported only if acsModemsTableProfile is set to dial-out(2). If none(1) or remote(3) is set, then the IP address fields will be cleared. When at least one IP address is set, this value will be local(2). If remote(3) is set, the remote peer should send both IP addresses (local and remote) during negotiation.
1.3.6.1.4.1.10418.26.2.8.2.1.8INTEGER {notApplicable(0), none(1), local(2), remote(3)}read-writecurrent
acsModemsTableLocalIpv4Address
OBJECT-TYPE
Configures the local IPv4 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.9DisplayString (SIZE(0..46))read-writecurrent
acsModemsTableRemoteIpv4Address
OBJECT-TYPE
Configures the remote IPv4 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.10DisplayString (SIZE(0..46))read-writecurrent
acsModemsTableLocalIPv6Address
OBJECT-TYPE
Configures the local IPv6 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.11DisplayString (SIZE(0..46))read-writecurrent
acsModemsTableRemoteIPv6Address
OBJECT-TYPE
Configures the remote IPv6 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.12DisplayString (SIZE(0..46))read-writecurrent
acsModemsTablePppAuthentication
OBJECT-TYPE
Configure the PPP authentication protocol. If this is set to remoteChap(5) or remotePap(6), then you must also set acsModemsTablePppRemoteUsername and acsModemsTablePppRemotePassphrase.
1.3.6.1.4.1.10418.26.2.8.2.1.13INTEGER {noAuth(1), localPap(2), localChap(3), localEap(4), remoteChap(5), remotePap(6)}read-writecurrent
acsModemsTablePppRemoteUsername
OBJECT-TYPE
Only used if acsModemsTablePppAuthentication is set to remoteChap(5) or remotePap(6).
1.3.6.1.4.1.10418.26.2.8.2.1.14DisplayString (SIZE(0..32))read-writecurrent
acsModemsTablePppRemotePassphrase
OBJECT-TYPE
Only used if acsModemsTablePppAuthentication is set to remoteChap(5) or remotePap(6).
1.3.6.1.4.1.10418.26.2.8.2.1.15DisplayString (SIZE(0..32))read-writecurrent
acsModemsTableChapInterval
OBJECT-TYPE
CHAP Interval in seconds. Default is 0. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.16Integer32read-writecurrent
acsModemsTableChapMaxChallenge
OBJECT-TYPE
CHAP Max Challenge value in seconds. Default is 10 seconds. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.17Integer32read-writecurrent
acsModemsTableChapRestart
OBJECT-TYPE
CHAP Restart value in seconds. Default is 3 seconds. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.18Integer32read-writecurrent
acsModemsTablePppIdleTimeout
OBJECT-TYPE
PPP idle timeout value in seconds. Default is 0. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.19Integer32read-writecurrent
acsModemsTableModel
OBJECT-TYPE
Modem vendor model name. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.20DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableCellProvider
OBJECT-TYPE
Cellular modem service provider. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.21DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableCellRegistration
OBJECT-TYPE
Cellular modem network registration. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.22DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableCCID
OBJECT-TYPE
SIM integrated circuit card identifier. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.23DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableIMSI
OBJECT-TYPE
International mobile subscriber identity. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.24DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableIMEI
OBJECT-TYPE
International mobile equipment identity. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.25DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableCellStatus
OBJECT-TYPE
Shows the status of the cellular modem. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.26DisplayString (SIZE(0..80))read-onlycurrent
acsModemsTableAPN
OBJECT-TYPE
Access point name. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.27DisplayString (SIZE(0..40))read-writecurrent
acsModemsTableMtuSize
OBJECT-TYPE
The maxiumum transmission unit size for use by the integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.28Integer32read-onlycurrent
acsModemsTableReplaceDefaultRoute
OBJECT-TYPE
If this is set to enabled(2), then the integrated cellular modem becomes the default gateway. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.29INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsModemsTablePersistMode
OBJECT-TYPE
If this is set to 'yes' then the integrated cellular modem connection persists. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.30INTEGER {notApplicable(0), disabled(1), enabled(2)}read-writecurrent
acsModemsTableSignalQualityCheck
OBJECT-TYPE
Check the signal quality of the integrated cellular modem. This turns on the modem transceiver to get the signal. The signal quality can be read in acsModemsTableSignalQualityDisplay.
1.3.6.1.4.1.10418.26.2.8.2.1.31INTEGER {notApplicable(0), no-action(1), signalCheck(2)}read-writecurrent
acsModemsTableSignalQualityDisplay
OBJECT-TYPE
Displays the last read signal quality of the integrated cellular modem. To refresh this value write signalCheck(2) to acsModemsTableSignalQualityCheck.
1.3.6.1.4.1.10418.26.2.8.2.1.32DisplayString (SIZE(0..80))read-writecurrent
acsModemsTableSIMStatus
OBJECT-TYPE
Status of the modem SIM card. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.33INTEGER {unknown(0), ready(1), waitingForPIN(2), waitingForUnlockCode(3), errorReadingSIM(4)}read-onlycurrent
acsModemsTableSIMPINEntry
OBJECT-TYPE
Modem SIM card PIN/Password entry. Writable only if acsModemsTableSIMStatus returns waitingForPIN(2). Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.34DisplayString (SIZE(0..80))read-writecurrent
acsModemsTableSIMUnlockCodeEntry
OBJECT-TYPE
Modem SIM card Unlock Code entry. Writable only if acsModemsTableSIMStatus returns waitingForUnlockCode(3). Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.35DisplayString (SIZE(0..80))read-writecurrent
acsModemsTableCellTestLastStarted
OBJECT-TYPE
The timestamp of the last time the Cell Modem IP Test started running. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.36DisplayString (SIZE(0..32))read-onlycurrent
acsModemsTableCellTestLastResult
OBJECT-TYPE
The result of the last time the Cell Modem IP Test was run. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.37DisplayString (SIZE(0..256))read-onlycurrent