ACD-ALARM-MIB
- Registered at
- 1.3.6.1.4.1.22420.2.1
- Last updated
- 2011-10-10 01:00
- Organization
- Accedian Networks, Inc.
- Revisions
- 2011-10-10 01:00, 2010-11-10 01:00, 2009-02-04 01:00, 2008-02-01 01:00, 2007-05-22 01:00, 2006-12-19 01:00, 2006-08-06 01:00
- Namespace
- accedian
- Source file
ACD-ALARM-MIB- Digest
sha256:d6e360322ea7ed5b9cef8a1963a4bf8e37de6d8c60b34267195391f6793079df
Description
The alarm Table for this Accedian Networks device.
Contact
Accedian Technical Assistance Center Accedian Networks, Inc. 4878 Levy, suite 202 Saint-Laurent, Quebec Canada H4R 2P1 E-mail: support@accedian.com
Imports
| From | Symbols |
|---|---|
| ACCEDIAN-SMI | acdMibs |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ACCEDIAN-SMI ACD-ALARM-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| acdAlarmGenThreshOn OBJECT-TYPE This value represents the Alarm On Hysteris. This is the time since the detection of the On event inside the system versus the report. This is to avoid storm of notifications. | 1.3.6.1.4.1.22420.2.1.1 | Unsigned32 (500..50000) | read-write | current |
| acdAlarmGenThreshOff OBJECT-TYPE This value represents the Alarm Off Hysteris. This is the time since the detection of the Off event inside the system versus the report. This is to avoid storm of notifications. | 1.3.6.1.4.1.22420.2.1.2 | Unsigned32 (500..50000) | read-write | current |
| acdAlarmGenLedEnable OBJECT-TYPE This is to Enable the alarms reporting through the LEDs. | 1.3.6.1.4.1.22420.2.1.3 | TruthValue | read-write | current |
| acdAlarmGenSyslogEnable OBJECT-TYPE This is to Enable the alarms reporting through the syslog system. | 1.3.6.1.4.1.22420.2.1.4 | TruthValue | read-write | current |
| acdAlarmGenSNMPEnable OBJECT-TYPE This is to Enable the alarms reporting through the SNMP agent. | 1.3.6.1.4.1.22420.2.1.5 | TruthValue | read-write | current |
| acdAlarmGen8023AHEnable OBJECT-TYPE This is to Enable the alarms reporting through the 802.3AH protocol. | 1.3.6.1.4.1.22420.2.1.6 | TruthValue | read-write | current |
| acdAlarmCfgTable OBJECT-TYPE Table of all alarms. | 1.3.6.1.4.1.22420.2.1.10 | not-accessible | current | |
| acdAlarmCfgEntry OBJECT-TYPE An alarm is an exceptional event that requires user notificaton. | 1.3.6.1.4.1.22420.2.1.10.1 | not-accessible | current | |
| acdAlarmCfgID OBJECT-TYPE Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes). | 1.3.6.1.4.1.22420.2.1.10.1.1 | Unsigned32 | read-only | current |
| acdAlarmCfgNumber OBJECT-TYPE Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8. | 1.3.6.1.4.1.22420.2.1.10.1.2 | Unsigned32 | read-only | current |
| acdAlarmCfgDesc OBJECT-TYPE This string is to describe the alarm in a readable way, e.g.: +5Vdc Power supply fail. | 1.3.6.1.4.1.22420.2.1.10.1.3 | DisplayString (SIZE(0..128)) | read-write | current |
| acdAlarmCfgEnable OBJECT-TYPE This is to indicate if the alarm is reported or not. | 1.3.6.1.4.1.22420.2.1.10.1.4 | TruthValue | read-write | current |
| acdAlarmCfgSeverity OBJECT-TYPE Accedian Networks classifies alarms into four severity types. These types and their associated decimal codes are, informational(0), minor(1), major(2) and critical(3). | 1.3.6.1.4.1.22420.2.1.10.1.5 | INTEGER {info(0), minor(1), major(2), critical(3)} | read-write | current |
| acdAlarmCfgServiceAffecting OBJECT-TYPE This is to indicate if the alarm is service affecting or not. This value depends on the utilization of the box. For instance in an application where the monitoring of the traffic is mandatory the link down event on the monitor port is service affecting. | 1.3.6.1.4.1.22420.2.1.10.1.6 | TruthValue | read-write | current |
| acdAlarmCfgExtNumber OBJECT-TYPE Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.B.C and is expressed in decimal, A is the module number, B is the instance number and C is the error number. A module number is assigned for each source of alarm in the system (see Accedian documentation for more detail). | 1.3.6.1.4.1.22420.2.1.10.1.7 | DisplayString (SIZE(0..16)) | read-only | current |
| acdAlarmCfgConditionType OBJECT-TYPE This is the type of alarm condition. | 1.3.6.1.4.1.22420.2.1.10.1.8 | DisplayString (SIZE(0..32)) | read-only | current |
| acdAlarmCfgAMOType OBJECT-TYPE This is the Alarm Maintenance Object. | 1.3.6.1.4.1.22420.2.1.10.1.9 | DisplayString (SIZE(0..128)) | read-only | current |
| acdAlarmStatusTable OBJECT-TYPE Table of all alarms | 1.3.6.1.4.1.22420.2.1.11 | not-accessible | current | |
| acdAlarmStatusEntry OBJECT-TYPE An alarm is an exceptional event that requires user notificaton. | 1.3.6.1.4.1.22420.2.1.11.1 | not-accessible | current | |
| acdAlarmStatusID OBJECT-TYPE Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes). | 1.3.6.1.4.1.22420.2.1.11.1.1 | Unsigned32 | read-only | current |
| acdAlarmStatusNumber OBJECT-TYPE Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8. | 1.3.6.1.4.1.22420.2.1.11.1.2 | Unsigned32 | read-only | current |
| acdAlarmStatusOn OBJECT-TYPE This is to indicate if the alarm is On or Off. | 1.3.6.1.4.1.22420.2.1.11.1.3 | TruthValue | read-only | current |
| acdAlarmStatusLastChange OBJECT-TYPE This is the time of the last change for this alarm. A value of zero means that nothing happened to this alarm since the last reboot. | 1.3.6.1.4.1.22420.2.1.11.1.4 | DateAndTime | read-only | current |
| acdAlarmStatusMsg OBJECT-TYPE This string is to add information why the alarm is reported. | 1.3.6.1.4.1.22420.2.1.11.1.5 | DisplayString (SIZE(0..32)) | read-only | current |
| acdAlarmV2 OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.12 | |||
| acdAlarmMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15 | |||
| acdAlarmConfig OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.1 | |||
| acdAlarmStatus OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.2 | |||
| acdAlarmConformance OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.3 | |||
| acdAlarmCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.3.1 | |||
| acdAlarmGroups OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.3.2 | |||
| acdAlarmTableTid OBJECT-IDENTITY | 1.3.6.1.4.1.22420.2.1.15.4 | |||
| acdAlarmCfgTableLastChangeTid OBJECT-TYPE This is the transaction ID of the last change of the acdAlarmCfgTable table. If this value is different since the last read this is indicate a table change. | 1.3.6.1.4.1.22420.2.1.15.4.1 | Unsigned32 | read-only | current |
| acdAlarmStatusTableLastChangeTid OBJECT-TYPE This is the transaction ID of the last change of the acdAlarmStatusTable table. If this value is different since the last read this is indicate a table change. | 1.3.6.1.4.1.22420.2.1.15.4.2 | Unsigned32 | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| acdAlarmActiveState NOTIFICATION-TYPE The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps. | 1.3.6.1.4.1.22420.2.1.12.1 | current |
| acdAlarmClearState NOTIFICATION-TYPE The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps. | 1.3.6.1.4.1.22420.2.1.12.2 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| acdAlarmCompliance MODULE-COMPLIANCE The compliance statement for support of the ACD-ALARM-MIB module. | 1.3.6.1.4.1.22420.2.1.15.3.1.1 | current |
| acdAlarmGenGroup OBJECT-GROUP . | 1.3.6.1.4.1.22420.2.1.15.3.2.1 | current |
| acdAlarmCfgGroup OBJECT-GROUP . | 1.3.6.1.4.1.22420.2.1.15.3.2.2 | current |
| acdAlarmStatusGroup OBJECT-GROUP . | 1.3.6.1.4.1.22420.2.1.15.3.2.3 | current |
| acdAlarmNotificationsGroup NOTIFICATION-GROUP Objects for the Notifications group. | 1.3.6.1.4.1.22420.2.1.15.3.2.4 | current |
| acdAlarmTidGroup OBJECT-GROUP List of scalars to monitior changes in tables. | 1.3.6.1.4.1.22420.2.1.15.3.2.5 | current |