MIBs Depot

ACD-ALARM-MIB

Registered at
1.3.6.1.4.1.22420.2.1
Last updated
2011-10-10 01:00
Organization
Accedian Networks, Inc.
Revisions
2011-10-10 01:00, 2010-11-10 01:00, 2009-02-04 01:00, 2008-02-01 01:00, 2007-05-22 01:00, 2006-12-19 01:00, 2006-08-06 01:00
Namespace
accedian
Source file
ACD-ALARM-MIB
Digest
sha256:d6e360322ea7ed5b9cef8a1963a4bf8e37de6d8c60b34267195391f6793079df

Description

The alarm Table for this Accedian Networks device.

Contact

Accedian Technical Assistance Center Accedian Networks, Inc. 4878 Levy, suite 202 Saint-Laurent, Quebec Canada H4R 2P1 E-mail: support@accedian.com

Imports

FromSymbols
ACCEDIAN-SMIacdMibs
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-MIBsysName
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ACCEDIAN-SMI
ACD-ALARM-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
acdAlarmGenThreshOn
OBJECT-TYPE
This value represents the Alarm On Hysteris. This is the time since the detection of the On event inside the system versus the report. This is to avoid storm of notifications.
1.3.6.1.4.1.22420.2.1.1Unsigned32 (500..50000)read-writecurrent
acdAlarmGenThreshOff
OBJECT-TYPE
This value represents the Alarm Off Hysteris. This is the time since the detection of the Off event inside the system versus the report. This is to avoid storm of notifications.
1.3.6.1.4.1.22420.2.1.2Unsigned32 (500..50000)read-writecurrent
acdAlarmGenLedEnable
OBJECT-TYPE
This is to Enable the alarms reporting through the LEDs.
1.3.6.1.4.1.22420.2.1.3TruthValueread-writecurrent
acdAlarmGenSyslogEnable
OBJECT-TYPE
This is to Enable the alarms reporting through the syslog system.
1.3.6.1.4.1.22420.2.1.4TruthValueread-writecurrent
acdAlarmGenSNMPEnable
OBJECT-TYPE
This is to Enable the alarms reporting through the SNMP agent.
1.3.6.1.4.1.22420.2.1.5TruthValueread-writecurrent
acdAlarmGen8023AHEnable
OBJECT-TYPE
This is to Enable the alarms reporting through the 802.3AH protocol.
1.3.6.1.4.1.22420.2.1.6TruthValueread-writecurrent
acdAlarmCfgTable
OBJECT-TYPE
Table of all alarms.
1.3.6.1.4.1.22420.2.1.10not-accessiblecurrent
acdAlarmCfgEntry
OBJECT-TYPE
An alarm is an exceptional event that requires user notificaton.
1.3.6.1.4.1.22420.2.1.10.1not-accessiblecurrent
acdAlarmCfgID
OBJECT-TYPE
Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.1.10.1.1Unsigned32read-onlycurrent
acdAlarmCfgNumber
OBJECT-TYPE
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
1.3.6.1.4.1.22420.2.1.10.1.2Unsigned32read-onlycurrent
acdAlarmCfgDesc
OBJECT-TYPE
This string is to describe the alarm in a readable way, e.g.: +5Vdc Power supply fail.
1.3.6.1.4.1.22420.2.1.10.1.3DisplayString (SIZE(0..128))read-writecurrent
acdAlarmCfgEnable
OBJECT-TYPE
This is to indicate if the alarm is reported or not.
1.3.6.1.4.1.22420.2.1.10.1.4TruthValueread-writecurrent
acdAlarmCfgSeverity
OBJECT-TYPE
Accedian Networks classifies alarms into four severity types. These types and their associated decimal codes are, informational(0), minor(1), major(2) and critical(3).
1.3.6.1.4.1.22420.2.1.10.1.5INTEGER {info(0), minor(1), major(2), critical(3)}read-writecurrent
acdAlarmCfgServiceAffecting
OBJECT-TYPE
This is to indicate if the alarm is service affecting or not. This value depends on the utilization of the box. For instance in an application where the monitoring of the traffic is mandatory the link down event on the monitor port is service affecting.
1.3.6.1.4.1.22420.2.1.10.1.6TruthValueread-writecurrent
acdAlarmCfgExtNumber
OBJECT-TYPE
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.B.C and is expressed in decimal, A is the module number, B is the instance number and C is the error number. A module number is assigned for each source of alarm in the system (see Accedian documentation for more detail).
1.3.6.1.4.1.22420.2.1.10.1.7DisplayString (SIZE(0..16))read-onlycurrent
acdAlarmCfgConditionType
OBJECT-TYPE
This is the type of alarm condition.
1.3.6.1.4.1.22420.2.1.10.1.8DisplayString (SIZE(0..32))read-onlycurrent
acdAlarmCfgAMOType
OBJECT-TYPE
This is the Alarm Maintenance Object.
1.3.6.1.4.1.22420.2.1.10.1.9DisplayString (SIZE(0..128))read-onlycurrent
acdAlarmStatusTable
OBJECT-TYPE
Table of all alarms
1.3.6.1.4.1.22420.2.1.11not-accessiblecurrent
acdAlarmStatusEntry
OBJECT-TYPE
An alarm is an exceptional event that requires user notificaton.
1.3.6.1.4.1.22420.2.1.11.1not-accessiblecurrent
acdAlarmStatusID
OBJECT-TYPE
Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.1.11.1.1Unsigned32read-onlycurrent
acdAlarmStatusNumber
OBJECT-TYPE
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
1.3.6.1.4.1.22420.2.1.11.1.2Unsigned32read-onlycurrent
acdAlarmStatusOn
OBJECT-TYPE
This is to indicate if the alarm is On or Off.
1.3.6.1.4.1.22420.2.1.11.1.3TruthValueread-onlycurrent
acdAlarmStatusLastChange
OBJECT-TYPE
This is the time of the last change for this alarm. A value of zero means that nothing happened to this alarm since the last reboot.
1.3.6.1.4.1.22420.2.1.11.1.4DateAndTimeread-onlycurrent
acdAlarmStatusMsg
OBJECT-TYPE
This string is to add information why the alarm is reported.
1.3.6.1.4.1.22420.2.1.11.1.5DisplayString (SIZE(0..32))read-onlycurrent
acdAlarmV2
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.12
acdAlarmMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15
acdAlarmConfig
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.1
acdAlarmStatus
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.2
acdAlarmConformance
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.3
acdAlarmCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.3.1
acdAlarmGroups
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.3.2
acdAlarmTableTid
OBJECT-IDENTITY
1.3.6.1.4.1.22420.2.1.15.4
acdAlarmCfgTableLastChangeTid
OBJECT-TYPE
This is the transaction ID of the last change of the acdAlarmCfgTable table. If this value is different since the last read this is indicate a table change.
1.3.6.1.4.1.22420.2.1.15.4.1Unsigned32read-onlycurrent
acdAlarmStatusTableLastChangeTid
OBJECT-TYPE
This is the transaction ID of the last change of the acdAlarmStatusTable table. If this value is different since the last read this is indicate a table change.
1.3.6.1.4.1.22420.2.1.15.4.2Unsigned32read-onlycurrent

Notifications

NameOIDStatus
acdAlarmActiveState
NOTIFICATION-TYPE
The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.22420.2.1.12.1current
acdAlarmClearState
NOTIFICATION-TYPE
The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.22420.2.1.12.2current

Conformance

NameOIDStatus
acdAlarmCompliance
MODULE-COMPLIANCE
The compliance statement for support of the ACD-ALARM-MIB module.
1.3.6.1.4.1.22420.2.1.15.3.1.1current
acdAlarmGenGroup
OBJECT-GROUP
.
1.3.6.1.4.1.22420.2.1.15.3.2.1current
acdAlarmCfgGroup
OBJECT-GROUP
.
1.3.6.1.4.1.22420.2.1.15.3.2.2current
acdAlarmStatusGroup
OBJECT-GROUP
.
1.3.6.1.4.1.22420.2.1.15.3.2.3current
acdAlarmNotificationsGroup
NOTIFICATION-GROUP
Objects for the Notifications group.
1.3.6.1.4.1.22420.2.1.15.3.2.4current
acdAlarmTidGroup
OBJECT-GROUP
List of scalars to monitior changes in tables.
1.3.6.1.4.1.22420.2.1.15.3.2.5current