AC-SS7-MIB
- Registered at
- 1.3.6.1.4.1.5003.9.10.12
- Last updated
- 2012-07-26 05:28
- Organization
- AudioCodes Ltd
- Namespace
- audiocodes
- Source file
AC-SS7-MIB- Digest
sha256:20daf4ecd1d8e567e37af5cfad323b5164107a6e94e4d6103c8ddac8944e213f
Contact
Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com
Imports
| From | Symbols |
|---|---|
| AUDIOCODES-TYPES-MIB | acBoardMibs, acGeneric, acProducts, acRegistrations, audioCodes |
| INET-ADDRESS-MIB | InetAddress, InetAddressType |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, RowStatus, TAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
AC-SS7-MIB AUDIOCODES-TYPES-MIB INET-ADDRESS-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| acSS7Configuration OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1 | |||
| acSS7MTP2 OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.1 | |||
| acSS7MTP2M3bSlDiscardCongThreshold OBJECT-TYPE This parameter concerns feature that prevents uncontrolled increase of the MTP2 Transmit queue when the upper levels ignores the usual flow control mechanism. Any new SL_TX_MSU_RQ is discarded when the number of msu queued on the TB or RTB overtakes the threshold. Value 0, means that this feature is not activated. Access: Offline. AC INI-Param: SS7M3bSlDiscardCongThreshold | 1.3.6.1.4.1.5003.9.10.12.1.1.1 | Unsigned32 (0..255) | read-write | current |
| acSS7MTP2AttribTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.1.21 | not-accessible | current | |
| acSS7MTP2AttribEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1 | not-accessible | current | |
| acSS7MTP2AttribIndex OBJECT-TYPE Index Field for line. AC INI-Param: SS7Mtp2Parms_Index | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.1 | Unsigned32 (0..3) | not-accessible | current |
| acSS7MTP2AttribIsUsed OBJECT-TYPE Is the row used by alink. If it is the entrow will be read. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.2 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7MTP2AttribLinkRate OBJECT-TYPE Defines the SS7 SLI Link Rate. Choose either: A = 64 kbps D = 56 kbps 0 = 64 kbps. Access: Online. AC INI-Param: SS7Mtp2Parms_LinkRate | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.3 | SnmpAdminString (SIZE(0..1)) | read-create | current |
| acSS7MTP2AttribErrorCorectionMethod OBJECT-TYPE Defines the SLI error correction method. B = Basic P = PCR (Preventive Cyclic Retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.4 | SnmpAdminString (SIZE(0..1)) | read-create | current |
| acSS7MTP2AttribIacCp OBJECT-TYPE Defines the number of aborted proving attempts before sending an out-of-service to MTP-3. Access: Online. AC INI-Param: SS7Mtp2Parms_IacCp | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.5 | Unsigned32 (0..10) | read-create | current |
| acSS7MTP2AttribSUERMThreshold OBJECT-TYPE Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermT | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.6 | Unsigned32 (0..256) | read-create | current |
| acSS7MTP2AttribAERMNormalThreshold OBJECT-TYPE Normal AERM (alignment error rate monitor) threshold [0 to 20]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTin | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.7 | Unsigned32 (0..20) | read-create | current |
| acSS7MTP2AttribAERMEmerglThreshold OBJECT-TYPE Emergency AERM (alignment error rate monitor) threshold [0 to 10]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTie | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.8 | Unsigned32 (0..10) | read-create | current |
| acSS7MTP2AttribSUERMSigUnitDThreshold OBJECT-TYPE Defines the SS7 Signal Unit error rate monitor D threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermSuD | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.9 | Unsigned32 (0..256) | read-create | current |
| acSS7MTP2AttribOctetCounting OBJECT-TYPE Defines the SS7 MTP2 Octet received while the OCTET is in counting mode (# of Octets received - N Octets - while in Octet counting mode). Access: Online. AC INI-Param: SS7Mtp2Parms_OctetCounting | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.10 | Unsigned32 (0..256) | read-create | current |
| acSS7MTP2AttribTimerT1 OBJECT-TYPE Defines the SS7 MTP2 T1 alignment ready timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T1 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.11 | Unsigned32 (0..100000) | read-create | current |
| acSS7MTP2AttribTimerT2 OBJECT-TYPE Defines the SS7 MTP2 T2 unaligned timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T2 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.12 | Unsigned32 (0..200000) | read-create | current |
| acSS7MTP2AttribTimerT3 OBJECT-TYPE Defines the SS7 MTP2 T3 timer aligned. Access: Online. AC INI-Param: SS7Mtp2Parms_T3 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.13 | Unsigned32 (0..20000) | read-create | current |
| acSS7MTP2AttribTimerT4Normal OBJECT-TYPE Defines the SS7 MTP2 T4n Normal proving period timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T4n | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.14 | Unsigned32 (0..15000) | read-create | current |
| acSS7MTP2AttribTimerT4Emerg OBJECT-TYPE Defines the SS7 MTP2 T4e Emergency proving period timer (msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T4e | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.15 | Unsigned32 (0..5000) | read-create | current |
| acSS7MTP2AttribTimerT5 OBJECT-TYPE Defines the SS7 MTP2 Sending SIB timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T5 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.16 | Unsigned32 (0..2400) | read-create | current |
| acSS7MTP2AttribTimerT6 OBJECT-TYPE Defines the SS7 MTP2 Remote Congestion timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T6 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.17 | Unsigned32 (0..10000) | read-create | current |
| acSS7MTP2AttribTimerT7 OBJECT-TYPE Defines the SS7 MTP2 excessive delay of the ack timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T7 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.18 | Unsigned32 (0..5000) | read-create | current |
| acSS7MTP2AttribLSSULength OBJECT-TYPE Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes). Access: Online. AC INI-Param: SS7Mtp2Parms_LssuLength | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.19 | Unsigned32 (1..2) | read-create | current |
| acSS7MTP2AttribPcrN2 OBJECT-TYPE This parameter is used to define Preventive Cyclic Retransmission - the number of message signal unit octets available for retransmission (ITU-T Q703 6.4 - Forced retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_PcrN2 | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.20 | Unsigned32 (0..512) | read-create | current |
| acSS7MTP2AttribRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.21 | RowStatus | read-create | obsolete |
| acSS7Timers OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.2 | |||
| acSS7SignalingNodeTimersTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.2.21 | not-accessible | current | |
| acSS7SignalingNodeTimersEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1 | not-accessible | current | |
| acSS7SignalingNodeTimersIndex OBJECT-TYPE Index Field for line. AC INI-Param: SS7_SNTIMERS_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.1 | Unsigned32 (0..4) | not-accessible | current |
| acSS7SignalingNodeTimersIsUsed OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.2 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7SignalingNodeTimersAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_SNTIMERS_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.3 | INTEGER {none(0)} | read-write | current |
| acSS7SignalingNodeTimersActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_SNTIMERS_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.4 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7SignalingNodeTimersName OBJECT-TYPE String name for SN timer-set. Access: Online. AC INI-Param: SS7_SNTIMERS_NAME | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.5 | SnmpAdminString (SIZE(0..15)) | read-write | current |
| acSS7SignalingNodeTimersT6 OBJECT-TYPE Delay to avoid message mis-sequencing on controlled rerouting. Access: Online. AC INI-Param: SS7_SNTIMERS_T6 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.6 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT8 OBJECT-TYPE Transfer prohibited inhibition timer (transient solution). Access: Online. AC INI-Param: SS7_SNTIMERS_T8 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.7 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT10 OBJECT-TYPE Waiting to repeat signalling route set test message. Access: Online. AC INI-Param: SS7_SNTIMERS_T10 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.8 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT11 OBJECT-TYPE Transfer restricted timer. Access: Online. AC INI-Param: SS7_SNTIMERS_T11 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.9 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT15 OBJECT-TYPE Waiting to start signalling route set congestion test. Access: Online. AC INI-Param: SS7_SNTIMERS_T15 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.10 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT16 OBJECT-TYPE Waiting for route set congestion status update. Access: Online. AC INI-Param: SS7_SNTIMERS_T16 | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.11 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT18ITU OBJECT-TYPE Timer within a signalling point whose MTP restarts for supervising link and link set activation as well as the receipt of routing information. Access: Online. AC INI-Param: SS7_SNTIMERS_T18_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.12 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT19ITU OBJECT-TYPE Supervision timer during MTP restart to avoid possible ping-pong of TFP, TFR and TRA messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T19_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.13 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT20ITU OBJECT-TYPE Overall MTP restart timer at the signalling point whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T20_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.14 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT21ITU OBJECT-TYPE Overall MTP restart timer at a signalling point adjacent to one whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T21_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.15 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT24ITU OBJECT-TYPE Stabilising timer after removal of local processor outage, used in LPO latching to RPO (national option). Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.16 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT22ANSI OBJECT-TYPE Timer at restarting SP waiting for signalling links to bacome available. Access: Online. AC INI-Param: SS7_SNTIMERS_T22_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.17 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT23ANSI OBJECT-TYPE Timer at restarting SP, started after T22, waiting to receive all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T23_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.18 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT24ANSI OBJECT-TYPE Timer at restarting SP with transfer function, started after T23, waiting to broadcast all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.19 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT25ANSI OBJECT-TYPE Timer at SP adjacent to restarting SP waiting for traffic restart allowed message. Access: Online. AC INI-Param: SS7_SNTIMERS_T25_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT26ANSI OBJECT-TYPE Timer at restarting SP waiting to repeat traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T26_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.21 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT27ANSI OBJECT-TYPE This parameter is used to define the minimum duration of unavailability for a full restart. Access: Online. AC INI-Param: SS7_SNTIMERS_T27_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.22 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT28ANSI OBJECT-TYPE Timer at SP adjacent to restarting SP waiting for traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T28_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.23 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT29ANSI OBJECT-TYPE Timer started when TRA sent in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T29_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.24 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7SignalingNodeTimersT30ANSI OBJECT-TYPE Timer to limit sending of TFPs and TFRs in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T30_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.25 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.2.22 | not-accessible | current | |
| acSS7LinkSetTimersEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1 | not-accessible | current | |
| acSS7LinkSetTimersIndex OBJECT-TYPE Index Field for line. AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.1 | Unsigned32 (0..4) | not-accessible | current |
| acSS7LinkSetTimersIsUsed OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.2 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7LinkSetTimersAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_LKSETTIMERS_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.3 | INTEGER {none(0)} | read-write | current |
| acSS7LinkSetTimersActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.4 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7LinkSetTimersName OBJECT-TYPE String name for Linkset timer-set. Access: Online. AC INI-Param: SS7_LKSETTIMERS_NAME | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.5 | SnmpAdminString (SIZE(0..15)) | read-write | current |
| acSS7LinkSetTimersT1SLT OBJECT-TYPE Supervision timer for signalling link test acknowledgement message. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1SLT | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.6 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT2SLT OBJECT-TYPE Interval timer for sending signalling link test messages. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2SLT | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.7 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT1 OBJECT-TYPE Delay to avoid message mis-sequencing on changeover. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.8 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT2 OBJECT-TYPE Waiting for changeover acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.9 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT3 OBJECT-TYPE Time controlled diversion-delay to avoid mis-sequencing on changeback. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T3 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.10 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT4 OBJECT-TYPE Waiting for changeback acknowledgement (first attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T4 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.11 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT5 OBJECT-TYPE Waiting for changeback acknowledgement (second attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T5 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.12 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT7 OBJECT-TYPE Waiting for signalling data link connection acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T7 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.13 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT12 OBJECT-TYPE Waiting for uninhibit acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T12 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.14 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT13 OBJECT-TYPE Waiting for force uninhibit. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T13 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.15 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT14 OBJECT-TYPE Waiting for inhibition acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T14 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.16 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT17 OBJECT-TYPE Delay to avoid oscillation of initial alignment failure and link restart. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T17 | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.17 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT20ANSI OBJECT-TYPE Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T20_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.18 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT21ANSI OBJECT-TYPE Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T21_ANSI | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.19 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT22ITU OBJECT-TYPE Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T22_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.20 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7LinkSetTimersT23ITU OBJECT-TYPE Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T23_ITU | 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.21 | Unsigned32 (500..2147483647) | read-write | current |
| acSS7Links OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.3 | |||
| acSS7LinkCommonTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.21 | not-accessible | current | |
| acSS7LinkCommonEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1 | not-accessible | current | |
| acSS7LinkCommonIndex OBJECT-TYPE Index Field for line. AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acSS7LinkCommonRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_LINK_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.2 | RowStatus | read-create | current |
| acSS7LinkCommonAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_LINK_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.3 | INTEGER {none(0), offLine(1), inService(2), activate(3), deActivate(4), inhibit(5), unInhibit(6), lpo(7), lpr(8)} | read-create | current |
| acSS7LinkCommonActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_LINK_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.4 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7LinkCommonName OBJECT-TYPE String name for Link paramaters. Access: Online. AC INI-Param: SS7_LINK_NAME | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.5 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7LinkCommonAdminState OBJECT-TYPE Administrative state of singnalling link. AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.6 | INTEGER {offLine(0), inService(2)} | read-only | current |
| acSS7LinkCommonOperState OBJECT-TYPE Operational state of singnalling link. AC INI-Param: SS7_LINK_OPERATIONAL_STATE | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.7 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7LinkCommonTraceLevel OBJECT-TYPE Trace level of singnalling link (level 2). Access: Online. AC INI-Param: SS7_LINK_TRACE_LEVEL | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.8 | INTEGER {traceLevel0(0), traceLevel1(1)} | read-create | current |
| acSS7LinkCommonL2TypeSelector OBJECT-TYPE Link layer 2 type - defines level 2 media of signaling link. Access: Online. AC INI-Param: SS7_LINK_L2_TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.9 | INTEGER {nonetype-L2(0), mtp2(1), m2ua-mgc(2), ss7monitoring(4)} | read-create | current |
| acSS7LinkCommonL3TypeSelector OBJECT-TYPE Link high layer type - defines level 3 or L2 high layer of signalling link. Access: Online. AC INI-Param: SS7_LINK_L3_TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.10 | INTEGER {nonetype-L3(0), m2ua-sg(1), mtp3(2), mtp2-tunneling(3), mtp2OverIP(4), ss7monitoring(5)} | read-create | current |
| acSS7LinkCommonVariant OBJECT-TYPE Variant (layer 2) of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_LAYER2_VARIANT | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.11 | INTEGER {itu(1), ansi(2), china(3)} | read-create | current |
| acSS7LinkCommonMtcBusy OBJECT-TYPE Link local busy indicator - if set, indicates link is busy due to local mtc action. AC INI-Param: SS7_LINK_MTC_BUSY | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.12 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7LinkCommonRdcyBoardNum OBJECT-TYPE Board number in which the link is physically connected. Access: Online. AC INI-Param: SS7_LINK_RDCY_BOARD | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.13 | INTEGER {rdcyBoardNum0(0), rdcyBoardNum1(1), rdcyBoardNum2(2)} | read-create | current |
| acSS7LinkCommonMonSuFilterRequest OBJECT-TYPE SS7 Monitoring link SU filter- Defines the type of SU message to filter. 0: Filter all types of SU messages 1: Filter LSSU and FISU messages 2: Filter only FISU messages 3: Do not filter any message. Access: Online. AC INI-Param: SS7_LINK_MON_SU_FILTER | 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.14 | INTEGER {filterAll(0), filterLSSUandFISU(1), filterFISU(2), noFilter(3)} | read-create | current |
| acSS7LinkTDMTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.22 | not-accessible | current | |
| acSS7LinkTDMEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1 | not-accessible | current | |
| acSS7LinkTDMTrunkNumber OBJECT-TYPE Trunk number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TRUNK_NUMBER | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.1 | Integer32 (-1..84) | read-create | current |
| acSS7LinkTDMTimeSlotNumber OBJECT-TYPE Time-Slot number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TIMESLOT_NUMBER | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.2 | Unsigned32 (1..31) | read-create | current |
| acSS7LinkTDMInhibit OBJECT-TYPE Link inhibit indicator - if set, indicates link is inhibited.. AC INI-Param: SS7_LINK_INHIBITION | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.3 | INTEGER {unInhibited(0), inhibited(1)} | read-only | current |
| acSS7LinkTDMMtp2Atts OBJECT-TYPE MTP2 attributes of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.4 | INTEGER {mtp2Atts0(0), mtp2Atts1(1), mtp2Atts2(2), mtp2Atts3(3)} | read-create | current |
| acSS7LinkTDMCongestionLowMark OBJECT-TYPE Link congestion low mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_LOW_MARK | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.5 | Unsigned32 (0..255) | read-create | current |
| acSS7LinkTDMCongestionHighMark OBJECT-TYPE Link congestion high mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_HIGH_MARK | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.6 | Unsigned32 (0..255) | read-create | current |
| acSS7LinkTDMBlock OBJECT-TYPE Link blocked indicator. AC INI-Param: SS7_LINK_BLOCKED | 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.7 | INTEGER {l3linkunblocked(0), l3linklocalblocked(1), l3linkremoteblockde(2), l3linklocalandremotelocked(3)} | read-only | current |
| acSS7LinkSigTranTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.23 | not-accessible | current | |
| acSS7LinkSigTranEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.23.1 | not-accessible | current | |
| acSS7LinkSigTranGroupId OBJECT-TYPE Group ID (M2UA) of signaling link. Access: Online. AC INI-Param: SS7_LINK_GROUP_ID | 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.1 | Integer32 (-1..65534) | read-create | current |
| acSS7LinkSigTranIfid OBJECT-TYPE Interface ID (M2UA) of singnalling link. Access: Online. AC INI-Param: SS7_LINK_M2UA_IF_ID | 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.2 | Integer32 (-1..2147483647) | read-create | current |
| acSS7LinkATMTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.24 | not-accessible | obsolete | |
| acSS7LinkATMEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1 | not-accessible | obsolete | |
| acSS7LinkATMSAALLinkProfileNum OBJECT-TYPE ATM SAAL Link profile number. Access: Online. AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.1 | Unsigned32 (0..128) | read-create | obsolete |
| acSS7LinkATMSAALLinkType OBJECT-TYPE ATM SAAL link Type PVC/SVC. Access: Online. AC INI-Param: ATM_SAAL_LINK_TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.2 | INTEGER {aTM-VCC-Type-PVC(0), aTM-VCC-Type-SVC(1)} | read-create | obsolete |
| acSS7LinkATMSAALLinkInterfaceNum OBJECT-TYPE ATM SAAL link port num. Access: Online. AC INI-Param: ATM_SAAL_LINK_PORT_NUM | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.3 | Unsigned32 (0..128) | read-create | obsolete |
| acSS7LinkATMSAALLinkVPI OBJECT-TYPE ATM SAAL link VPI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VPI | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.4 | Unsigned32 (0..255) | read-create | obsolete |
| acSS7LinkATMSAALLinkVCI OBJECT-TYPE ATM SAAL link VCI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VCI | 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.5 | Unsigned32 (0..65536) | read-create | obsolete |
| acSS7LinkTNLTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.25 | not-accessible | current | |
| acSS7LinkTNLEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1 | not-accessible | current | |
| acSS7LinkTNLOtherSideLinkNum OBJECT-TYPE MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling link). Access: Online. AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.1 | Unsigned32 (0..128) | read-create | current |
| acSS7LinkTNLAlignmentMode OBJECT-TYPE MTP2 Tunneling: Alignment mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.2 | INTEGER {normal(0), emergency(1)} | read-create | current |
| acSS7LinkTNLCongestionMode OBJECT-TYPE MTP2 Tunneling: Congestion mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.3 | INTEGER {accept(0), discard(1)} | read-create | current |
| acSS7LinkTNLWaitStartCompTimer OBJECT-TYPE MTP2 Tunneling: wait start complete timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.4 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7LinkTNLOosStartDelayTimer OBJECT-TYPE MTP2 Tunneling: OOS start delay timer. Access: Online. AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.5 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7LinkTNLWaitOtherSideInsvTimer OBJECT-TYPE MTP2 Tunneling: wait for other side to be in service timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER | 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.6 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7Nodes OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.4 | |||
| acSS7SignalingNodeTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.21 | not-accessible | current | |
| acSS7SignalingNodeEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1 | not-accessible | current | |
| acSS7SignalingNodeIndex OBJECT-TYPE AC INI-Param: SS7_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7SignalingNodeRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_SN_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.2 | RowStatus | read-create | current |
| acSS7SignalingNodeAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_SN_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.3 | INTEGER {none(0), stop(1), start(2), inService(3), offLine(4)} | read-create | current |
| acSS7SignalingNodeActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.4 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7SignalingNodeName OBJECT-TYPE String name for SN Params. Access: Online. AC INI-Param: SS7_SN_NAME | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.5 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7SignalingNodeTraceLevel OBJECT-TYPE Trace level of singnalling node (level 3). Access: Online. AC INI-Param: SS7_SN_TRACE_LEVEL | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.6 | INTEGER {traceLevel0(0), traceLevel1(1)} | read-create | current |
| acSS7SignalingNodeAdminState OBJECT-TYPE Administrative state of singnalling node. AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.7 | INTEGER {offLine(0), inService(2)} | read-only | current |
| acSS7SignalingNodeOperState OBJECT-TYPE Operational state of singnalling node. AC INI-Param: SS7_SN_OPERATIONAL_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.8 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7SignalingNodeMtcBusy OBJECT-TYPE Manual busy status of singnalling node. AC INI-Param: SS7_SN_MTC_BUSY_STATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.9 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7SignalingNodeVariant OBJECT-TYPE Variant of singnalling node. Access: Online. AC INI-Param: SS7_SN_VARIANT | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.10 | INTEGER {itu(1), ansi(2), china(3)} | read-create | current |
| acSS7SignalingNodeNwIndicator OBJECT-TYPE Network Indicator of singnalling node. Access: Online. AC INI-Param: SS7_SN_NI | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.11 | INTEGER {international(0), internationalSpare(1), national(2), nationalSpare(3)} | read-create | current |
| acSS7SignalingNodeSpStp OBJECT-TYPE Routing function of singnalling node. Access: Online. AC INI-Param: SS7_SN_SP_STP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.12 | INTEGER {sp(0), stp(1)} | read-create | current |
| acSS7SignalingNodeTfc OBJECT-TYPE TFC function of singnalling node. Access: Online. AC INI-Param: SS7_SN_TFC | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.13 | INTEGER {no(0), yes(1)} | read-create | current |
| acSS7SignalingNodeOpc OBJECT-TYPE Origination (local) point-code of singnalling node. Access: Online. AC INI-Param: SS7_SN_OPC | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.14 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7SignalingNodeRouteSetCongestionWindow OBJECT-TYPE Routeset Congestion Size (messages) of singnalling node. Access: Online. AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.15 | Unsigned32 (0..255) | read-create | current |
| acSS7SignalingNodeTimersIdx OBJECT-TYPE Index of SNTimers table used for this signaling node. Access: Online. AC INI-Param: SS7_SN_TIMERS_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.16 | INTEGER {timersIdx0(0), timersIdx1(1), timersIdx2(2), timersIdx3(3), timersIdx4(4)} | read-create | current |
| acSS7SignalingNodeIsupApp OBJECT-TYPE Level 4 application that handles ISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ISUP_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.17 | INTEGER {nill(0), ual(4), l4Gen(7)} | read-create | current |
| acSS7SignalingNodeSccpApp OBJECT-TYPE Level 4 application that handles SCCP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_SCCP_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.18 | INTEGER {nill(0), ual(4), l4Gen(7)} | read-create | current |
| acSS7SignalingNodeBisupApp OBJECT-TYPE Level 4 application that handles BISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_BISUP_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.19 | INTEGER {nill(0), ual(4), l4Gen(7)} | read-create | current |
| acSS7SignalingNodeAlcapApp OBJECT-TYPE Level 4 application that handles ALCAP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ALCAP_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.20 | INTEGER {nill(0), ual(4), alcap(5), l4Gen(7)} | read-create | deprecated |
| acSS7SignalingNodeRdcyOpc OBJECT-TYPE Internal point-code of singnalling node - in case of SS7 shared point code. AC INI-Param: SS7_SN_RDCY_OPC | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.21 | Unsigned32 (0..2147483647) | read-only | current |
| acSS7SignalingNodeTupApp OBJECT-TYPE Level 4 application that handles TUP traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_TUP_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.22 | INTEGER {nill(0), ual(4), l4Gen(7)} | read-create | current |
| acSS7SignalingNodeBiccApp OBJECT-TYPE Level 4 application that handles BICC traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_BICC_APP | 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.23 | INTEGER {nil(0), ual(4)} | read-create | current |
| acSS7LinkSets OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.4.31 | |||
| acSS7LinkSetTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21 | not-accessible | current | |
| acSS7LinkSetEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1 | not-accessible | current | |
| acSS7LinkSetSNIndex OBJECT-TYPE First Index Field for line. AC INI-Param: SS7_LINKSET_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7LinkSetLksetIndex OBJECT-TYPE Second Index Field for line. AC INI-Param: SS7_LINKSET_LINKSET_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.2 | Unsigned32 (0..31) | not-accessible | current |
| acSS7LinkSetRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_LINKSET_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.3 | RowStatus | read-create | current |
| acSS7LinkSetAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_LINKSET_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.4 | INTEGER {none(0), offLine(1), inService(2), activate(3), deActivate(4)} | read-create | current |
| acSS7LinkSetActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.5 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7LinkSetName OBJECT-TYPE String name for LINKSET Params. Access: Online. AC INI-Param: SS7_LINKSET_NAME | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.6 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7LinkSetAdminState OBJECT-TYPE Administrative state of singnalling linkset. AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.7 | INTEGER {offLine(0), inService(2)} | read-only | current |
| acSS7LinkSetOperState OBJECT-TYPE Operational state of singnalling linkset. AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.8 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7LinkSetMtcBusyState OBJECT-TYPE Manual busy status of singnalling linkset. AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.9 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7LinkSetDPC OBJECT-TYPE Destination Point-Code of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_DPC | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.10 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7LinkSetLinksMask OBJECT-TYPE Mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_MASK | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.11 | Unsigned32 (0..255) | read-create | current |
| acSS7LinkSetLinksAltMask OBJECT-TYPE Alternate mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_ALTERNATE_MASK | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.12 | Unsigned32 (0..255) | read-create | current |
| acSS7LinkSetTimersIdx OBJECT-TYPE Timers Index of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_TIMERS_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.13 | INTEGER {timersIdx0(0), timersIdx1(1), timersIdx2(2), timersIdx3(3), timersIdx4(4)} | read-create | current |
| acSS7LinkSetLinkTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22 | not-accessible | current | |
| acSS7LinkSetLinkEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1 | not-accessible | current | |
| acSS7LinkSetLinkSNIndex OBJECT-TYPE First Index Field for line: Signalling Node Number. AC INI-Param: SS7_LINKSETLINK_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7LinkSetLinkLinksetIndex OBJECT-TYPE Second Index Field for line: Signalling Linkset Number. AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.2 | Unsigned32 (0..31) | not-accessible | current |
| acSS7LinkSetLinkInnerLinkIndex OBJECT-TYPE Third Index Field for line: Inner Link Index in Signalling Linkset. AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.3 | Unsigned32 (0..7) | not-accessible | current |
| acSS7LinkSetLinkRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_LINKSETLINK_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.4 | RowStatus | read-create | current |
| acSS7LinkSetLinkAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_LINKSETLINK_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.5 | INTEGER {none(0)} | read-create | current |
| acSS7LinkSetLinkActionResult OBJECT-TYPE Management field for ACTIONS RESULT. AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.6 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7LinkSetLinkLinkNo OBJECT-TYPE Physical number of signalling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.7 | Unsigned32 (0..128) | read-create | current |
| acSS7LinkSetLinkLinkSlc OBJECT-TYPE SLC number of signaling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_SLC | 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.8 | Unsigned32 (0..15) | read-create | current |
| acSS7RouteSets OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.4.32 | |||
| acSS7RouteSetTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21 | not-accessible | current | |
| acSS7RouteSetEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1 | not-accessible | current | |
| acSS7RouteSetSNIndex OBJECT-TYPE First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESET_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7RouteSetIndex OBJECT-TYPE Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESET_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.2 | Unsigned32 (0..29) | not-accessible | current |
| acSS7RouteSetRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESET_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.3 | RowStatus | read-create | current |
| acSS7RouteSetAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_ROUTESET_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.4 | INTEGER {none(0), offLine(1), inService(2)} | read-create | current |
| acSS7RouteSetActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESET_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.5 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7RouteSetName OBJECT-TYPE String name for ROUTESET Params. Access: Online. AC INI-Param: SS7_ROUTESET_NAME | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.6 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7RouteSetAdminState OBJECT-TYPE Administrative state of signalling route set. AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.7 | INTEGER {offLine(0), inService(2)} | read-only | current |
| acSS7RouteSetOperState OBJECT-TYPE Operational state of signalling route set. AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.8 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7RouteSetDPC OBJECT-TYPE Destination Point-Code of singnalling routesetset. Access: Online. AC INI-Param: SS7_ROUTESET_DPC | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.9 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7RouteSetRouteMask OBJECT-TYPE Mask for route within signaling routeset. Access: Online. AC INI-Param: SS7_ROUTESET_MASK | 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.10 | Unsigned32 (0..255) | read-create | current |
| acSS7RouteSetRouteTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22 | not-accessible | current | |
| acSS7RouteSetRouteEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1 | not-accessible | current | |
| acSS7RouteSetRouteSNIndex OBJECT-TYPE First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7RouteSetRouteRoutesetIndex OBJECT-TYPE Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.2 | Unsigned32 (0..29) | not-accessible | current |
| acSS7RouteSetRouteInnerRouteIndex OBJECT-TYPE Third Index Field for line: Inner Route Index in Signalling Routeset. AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.3 | Unsigned32 (0..3) | not-accessible | current |
| acSS7RouteSetRouteRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.4 | RowStatus | read-create | current |
| acSS7RouteSetRouteAction OBJECT-TYPE management Field for ACTIONS. AC INI-Param: SS7_ROUTESETROUTE_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.5 | INTEGER {none(0)} | read-create | current |
| acSS7RouteSetRouteActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.6 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7RouteSetRouteLinkSetNo OBJECT-TYPE Number of signalling linkset which is part of the Routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.7 | Unsigned32 (0..128) | read-create | current |
| acSS7RouteSetRoutePriority OBJECT-TYPE Priority of route within routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_PRIORITY | 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.8 | Unsigned32 (0..254) | read-create | current |
| acSS7AliasPointCode OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.4.33 | |||
| acSS7APCTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21 | not-accessible | current | |
| acSS7APCEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1 | not-accessible | current | |
| acSS7APCSNIndex OBJECT-TYPE First Index Field for line: Signaling Node Number. AC INI-Param: SS7_APC_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.1 | Unsigned32 (0..1) | not-accessible | current |
| acSS7APCIndex OBJECT-TYPE Second Index Field for line: Alias PC index. AC INI-Param: SS7_APC_INNER_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.2 | Unsigned32 (0..1) | not-accessible | current |
| acSS7APCRowStatus OBJECT-TYPE ROWSTATUS Field for line. AC INI-Param: SS7_APC_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.3 | RowStatus | read-create | current |
| acSS7APCAction OBJECT-TYPE Management field for ACTIONS. AC INI-Param: SS7_APC_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.4 | INTEGER {none(0), offLine(1), inService(2), activate(3), deActivate(4)} | read-create | current |
| acSS7APCActionResult OBJECT-TYPE management Field for ACTIONS RESULT. AC INI-Param: SS7_APC_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.5 | INTEGER {succeeded(0), inProgress(1), failed(2)} | read-only | current |
| acSS7APCPC OBJECT-TYPE Alias Point-Code of signaling node. Access: Online. AC INI-Param: SS7_APC_PC | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.6 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7APCSNI OBJECT-TYPE SNI (Signaling Network Indicator) of Alias Point-Code. Access: Online. AC INI-Param: SS7_APC_SNI | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.7 | Unsigned32 (2..5) | read-create | current |
| acSS7APCName OBJECT-TYPE String name for Alias PC parameters. Access: Online. AC INI-Param: SS7_ALIAS_PC_NAME | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.8 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7APCMtcBusy OBJECT-TYPE Manual busy status of Alias PC. AC INI-Param: SS7_ALIAS_PC_MTC_BUSY | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.9 | INTEGER {no(0), yes(1)} | read-only | current |
| acSS7APCAdminState OBJECT-TYPE Administrative state of Alias PC. AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.10 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7APCOperState OBJECT-TYPE Operational state of Alias PC. AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE | 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.11 | INTEGER {offLine(0), busy(1), inService(2)} | read-only | current |
| acSS7SigTran OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.5 | |||
| acSS7SigTranM3UATrafficBehavior OBJECT-TYPE Defines the M3UA behavior when the SS7 links are up, but there is no association to the soft switch. 0 = NONE (no special behavior) 1 = DEACTIVATE (busy links) 2 = SIPO (LPO links). Access: Offline. AC INI-Param: SS7M3UATrafficBehavior | 1.3.6.1.4.1.5003.9.10.12.1.5.1 | INTEGER {none(0), deactivate(1), sIPO(2)} | read-write | current |
| acSS7SigTranIFGroupTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.21 | not-accessible | current | |
| acSS7SigTranIFGroupEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1 | not-accessible | current | |
| acSS7SigTranIFGroupIndex OBJECT-TYPE Index field for line. AC INI-Param: SS7_SIG_IF_GR_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.1 | Unsigned32 (0..15) | not-accessible | current |
| acSS7SigTranIFGroupRowStatus OBJECT-TYPE ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.2 | RowStatus | read-create | current |
| acSS7SigTranIFGroupAction OBJECT-TYPE Management field for ACTION. AC INI-Param: SS7_SIG_IF_GR_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.3 | INTEGER {none(0), activate(1), deActivate(2)} | read-create | current |
| acSS7SigTranIFGroupActionResult OBJECT-TYPE Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.4 | Unsigned32 (0..2147483647) | read-only | current |
| acSS7SigTranIFGroupId OBJECT-TYPE SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface Group Id. Access: Online. AC INI-Param: SS7_IF_GR_ID | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.5 | Unsigned32 (0..65534) | read-create | current |
| acSS7SigTranIFGroupSgMgc OBJECT-TYPE Interface Group function - Signaling Gateway (SG) or Media Gateway Controller (MGC). Access: Online. AC INI-Param: SS7_SIG_SG_MGC | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.6 | INTEGER {nat(1), mgc(77), sg(83)} | read-create | current |
| acSS7SigTranIFGroupSignalingLayer OBJECT-TYPE UAL type of interface group: 0 = none 1 = iua 2 = m2ua 3 = m3ua 4 = m2tunnel 6 = dua. Access: Online. AC INI-Param: SS7_SIG_LAYER | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.7 | INTEGER {noLayer(0), iua(1), m2ua(2), m3ua(3), m2tunnel(4), dua(6)} | read-create | current |
| acSS7SigTranIFGroupTrafMode OBJECT-TYPE Traffic mode of interface group. Access: Online. AC INI-Param: SS7_SIG_TRAF_MODE | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.8 | INTEGER {override(1), loadShare(2), broadcast(3)} | read-create | current |
| acSS7SigTranIFGroupRecovTimer OBJECT-TYPE T(r) - recovery timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_REC | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.9 | Unsigned32 (0..10000000) | read-create | current |
| acSS7SigTranIFGroupAckTimer OBJECT-TYPE T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_ACK | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.10 | Unsigned32 (0..10000000) | read-create | current |
| acSS7SigTranIFGroupHBTimer OBJECT-TYPE T(beat) - Heartbeat Timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_HB | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.11 | Unsigned32 (0..10000000) | read-create | current |
| acSS7SigTranIFGroupMinAsp OBJECT-TYPE Minimal ASP (Application Server Process) number in interface group(minimum = 1). Access: Online. AC INI-Param: SS7_SIG_MIN_ASP | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.12 | Unsigned32 (1..10) | read-create | current |
| acSS7SigTranIFGroupBehavior OBJECT-TYPE Behavior bit of interface group. Access: Online. AC INI-Param: SS7_SIG_BEHAVIOUR | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.13 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7SigTranIFGroupSCTPInst OBJECT-TYPE SCTP (Stream Control Transmission Protocol) instance of interface group. AC INI-Param: SS7_SCTP_INSTANCE | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.14 | Unsigned32 (0..65534) | read-only | current |
| acSS7SigTranIFGroupSCTPLocalPort OBJECT-TYPE Local SCTP (Stream Control Transmission Protocol) port of interface group. Access: Online. AC INI-Param: SS7_LOCAL_SCTP_PORT | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.15 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7SigTranIFGroupNetwork OBJECT-TYPE Network variant of interface group. Access: Online. AC INI-Param: SS7_SIG_NETWORK | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.16 | INTEGER {itu(1), ansi(2), china(3)} | read-create | current |
| acSS7SigTranIFGroupSCTPDestPort OBJECT-TYPE Destination SCTP (Stream Control Transmission Protocol) port. Access: Online. AC INI-Param: SS7_DEST_SCTP_PORT | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.17 | Unsigned32 (0..65534) | read-create | current |
| acSS7SigTranIFGroupDestIp OBJECT-TYPE Destination SCTP (Stream Control Transmission Protocol) IP address. Access: Online. AC INI-Param: SS7_DEST_IP | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.18 | IpAddress | read-create | current |
| acSS7SigTranIFGroupSCTPMaxInbStreams OBJECT-TYPE Maximum inbound streams in interface group. Access: Online. AC INI-Param: SS7_MGC_MX_IN_STREAM | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.19 | Unsigned32 (2..65534) | read-create | current |
| acSS7SigTranIFGroupSCTPMaxOutbStreams OBJECT-TYPE Number of output streams required in interface group. Access: Online. AC INI-Param: SS7_MGC_NUM_OUT_STREAM | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.20 | Unsigned32 (2..65534) | read-create | current |
| acSS7SigTranIFGroupRdcyBoardNum OBJECT-TYPE This parameter is used to specify the SIGTRAN (Signaling Transport) group redundancy board number. Access: Online. AC INI-Param: RdcyBoardNum | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.21 | Unsigned32 (0..255) | read-create | current |
| acSS7SigTranIFGroupRoutingContextIndex OBJECT-TYPE Entry in Routing Context table, that contains the routing context rules for this interface group. Access: Online. AC INI-Param: SS7_SIG_RC_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.22 | Integer32 (-1..15) | read-create | current |
| acSS7SigTranIFGroupRoutingContextValue OBJECT-TYPE Routing context value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_RC_VALUE | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.23 | Integer32 (-1..2147483647) | read-create | current |
| acSS7SigTranIFGroupNetworkAppearance OBJECT-TYPE Network Appearance value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_NETWORK_APPEARANCE | 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.24 | Integer32 (-1..2147483647) | read-create | current |
| acSS7SigTranIFIDTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.22 | not-accessible | current | |
| acSS7SigTranIFIDEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1 | not-accessible | current | |
| acSS7SigTranIFIDIndex OBJECT-TYPE Index field for line. AC INI-Param: SS7_SIG_IF_ID_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.1 | Unsigned32 (0..83) | not-accessible | current |
| acSS7SigTranIFIDRowStatus OBJECT-TYPE ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.2 | RowStatus | read-create | current |
| acSS7SigTranIFIDAction OBJECT-TYPE Management field for ACTION. AC INI-Param: SS7_SIG_IF_ID_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.3 | INTEGER {none(0), activate(1), deActivate(2)} | read-create | current |
| acSS7SigTranIFIDActionResult OBJECT-TYPE Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.4 | Unsigned32 (0..2147483647) | read-only | current |
| acSS7SigTranIFIDValue OBJECT-TYPE SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID value. Access: Online. AC INI-Param: SS7_SIG_IF_ID_VALUE | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.5 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7SigTranIFIDName OBJECT-TYPE SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID name (text string). Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAME | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.6 | SnmpAdminString (SIZE(0..15)) | read-create | current |
| acSS7SigTranIFIDOwnerGroup OBJECT-TYPE Owner group of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.7 | Integer32 (-1..65534) | read-create | current |
| acSS7SigTranIFIDSignalingLayer OBJECT-TYPE UAL Type of interface id: 0 = none 1 = iua 2 = m2ua 4 = m2tunnel 6 = dua. Access: Online. AC INI-Param: SS7_SIG_IF_ID_LAYER | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.8 | INTEGER {noLayer(0), iua(1), m2ua(2), m2tunnel(4), dua(6)} | read-create | current |
| acSS7SigTranIFIDNai OBJECT-TYPE NAI of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAI | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.9 | Integer32 (-2..124) | read-create | current |
| acSS7SigTranIFIDM3UASpc OBJECT-TYPE This parameter is used to specify the SIGTRAN (Signaling Transport) M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC. Access: Online. AC INI-Param: SS7_SIG_M3UA_SPC | 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.10 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7M3UAStaticRoutingTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.23 | not-accessible | obsolete | |
| acSS7M3UAStaticRoutingEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1 | not-accessible | obsolete | |
| acSS7M3UAStaticRoutingIndex OBJECT-TYPE This parameter is used for the Signaling System 7 (SS7) interface ID index, for a line. AC INI-Param: M3UAROUTINGCLIST_Index | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.1 | Unsigned32 (0..100) | not-accessible | obsolete |
| acSS7M3UAStaticRoutingRowStatus OBJECT-TYPE This parameter is used for the Signaling System 7 (SS7) interface ID row status, for a line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.2 | RowStatus | read-create | obsolete |
| acSS7M3UAStaticRoutingAction OBJECT-TYPE This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for actions. AC INI-Param: SS7_SIG_IF_ID_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.3 | INTEGER {none(0), activate(1), deActivate(2)} | read-create | obsolete |
| acSS7M3UAStaticRoutingActionResult OBJECT-TYPE This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for an action's results. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.4 | Unsigned32 (0..2147483647) | read-only | obsolete |
| acSS7M3UAStaticRoutingOwnerInterfaceGroup OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.5 | Unsigned32 (0..30) | read-create | obsolete |
| acSS7M3UAStaticRoutingRC OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_RoutingContext | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.6 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingDestinationPointCode OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.7 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingNetworkAppearence OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.8 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingSeriviceIndicatorList OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.9 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingOPC1 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC1 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.10 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingOPC2 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC2 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.11 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingOPC3 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC3 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.12 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingOPC4 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC4 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.13 | Unsigned32 (0..16777215) | read-create | obsolete |
| acSS7M3UAStaticRoutingLowerCICValue1 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.14 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingUpperCICValue1 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.15 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingLowerCICValue2 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.16 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingUpperCICValue2 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.17 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingLowerCICValue3 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.18 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingUpperCICValue3 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.19 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingLowerCICValue4 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.20 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7M3UAStaticRoutingUpperCICValue4 OBJECT-TYPE Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4 | 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.21 | Unsigned32 (0..65535) | read-create | obsolete |
| acSS7SigTranRoutingContextTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.24 | not-accessible | current | |
| acSS7SigTranRoutingContextEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1 | not-accessible | current | |
| acSS7SigTranRoutingContextIndex OBJECT-TYPE First index field for line. AC INI-Param: SS7_RC_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.1 | Unsigned32 (0..31) | not-accessible | current |
| acSS7SigTranRoutingContextInnerIndex OBJECT-TYPE Second index field for line. AC INI-Param: SS7_RC_INNER_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.2 | Unsigned32 (0..3) | not-accessible | current |
| acSS7SigTranRoutingContextRowStatus OBJECT-TYPE ROWSTATUS field for line. AC INI-Param: SS7_RC_ROW_STATUS | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.3 | RowStatus | read-create | current |
| acSS7SigTranRoutingContextAction OBJECT-TYPE Management field for ACTIONS. AC INI-Param: RCAction | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.4 | INTEGER {none(0), activate(1), deActivate(2)} | read-create | current |
| acSS7SigTranRoutingContextActionResult OBJECT-TYPE RCActionRes. AC INI-Param: SS7_RC_ACTION_RES | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.5 | Unsigned32 (0..2147483647) | read-only | current |
| acSS7SigTranRoutingContextSnIdx OBJECT-TYPE This parameter is used to specify the M3UA Routing Context DPC SN-Index. Access: Online. AC INI-Param: SS7_RC_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.6 | Unsigned32 (0..5) | read-create | current |
| acSS7SigTranRoutingContextSpc OBJECT-TYPE This parameter is used to specify the M3UA Routing Context DPC parameter. AC INI-Param: SS7_RC_SPC | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.7 | Integer32 (-1..16777215) | read-only | current |
| acSS7SigTranRoutingContextOpc1 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context,First element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC1 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.8 | Integer32 (-1..16777215) | read-create | current |
| acSS7SigTranRoutingContextOpc2 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context,Second element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC2 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.9 | Integer32 (-1..16777215) | read-create | current |
| acSS7SigTranRoutingContextOpc3 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, Third element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC3 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.10 | Integer32 (-1..16777215) | read-create | current |
| acSS7SigTranRoutingContextOpc4 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, Fourth element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC4 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.11 | Integer32 (-1..16777215) | read-create | current |
| acSS7SigTranRoutingContextSi1 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, First element of SI list. Access: Online. AC INI-Param: SS7_RC_SI1 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.12 | Integer32 (-1..15) | read-create | current |
| acSS7SigTranRoutingContextSi2 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, Second element of SI list. Access: Online. AC INI-Param: SS7_RC_SI2 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.13 | Integer32 (-1..15) | read-create | current |
| acSS7SigTranRoutingContextSi3 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, Third element of SI list. Access: Online. AC INI-Param: SS7_RC_SI3 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.14 | Integer32 (-1..15) | read-create | current |
| acSS7SigTranRoutingContextSi4 OBJECT-TYPE This parameter is used to specify the M3UA Routing Context, Fourth element of SI list. Access: Online. AC INI-Param: SS7_RC_SI4 | 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.15 | Integer32 (-1..15) | read-create | current |
| acSS7Redundancy OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.1.6 | |||
| acSS7RedundancyCrossLinkTransferType OBJECT-TYPE Defines the cross-board connection media type for the MTP3 redundancy feature: 0 = M3BRDCY_CONN_TYPE_NONE 2 = M3BRDCY_CONN_TYPE_TCP. Access: Offline. AC INI-Param: SS7MTP3RdcyTransferType | 1.3.6.1.4.1.5003.9.10.12.1.6.1 | INTEGER {none(0), tcp(2)} | read-write | current |
| acSS7RedundancyMode OBJECT-TYPE Defines the MTP3 Signaling redundancy mode: 0 = Disabled 1 = Enabled . Access: Offline. AC INI-Param: SS7MTP3RdcyMode | 1.3.6.1.4.1.5003.9.10.12.1.6.2 | INTEGER {disable(0), enable(1)} | read-write | current |
| acSS7RedundancyBoardNum OBJECT-TYPE Defines the board number for the SS7 (Signaling System 7) MTP3 redundancy mode. Each board is allocated a unique number. All boards share a single redundancy table. Access: Offline. AC INI-Param: SS7MTP3RdcyBoardNum | 1.3.6.1.4.1.5003.9.10.12.1.6.3 | Unsigned32 (0..2) | read-write | current |
| acSS7RedundancyCrossLinkTraceAll OBJECT-TYPE When set via INI-file, activates trace output for all X-links (only when SS7 redundancy is configured). . Access: Instant. AC INI-Param: SS7M3BRdcyXlinkTraceAll | 1.3.6.1.4.1.5003.9.10.12.1.6.4 | INTEGER {disable(0), enable(1)} | read-write | obsolete |
| acSS7RedundancyMTP3RdcyTblSyncInterval OBJECT-TYPE Defines the interval between SS7 tables automatic synchronizations, in minutes. 0 = no automatic synchronization is activated. . Access: Instant. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.6.5 | Unsigned32 (0..144000) | read-write | current |
| acSS7RedundancySyncAllBoards OBJECT-TYPE Provide SYNC all boards command. Access: Instant. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.6.6 | INTEGER {noAction(0), sync(1)} | read-write | current |
| acSS7RedundancySyncBoard OBJECT-TYPE Provide SYNC between this board and another specific board (parameter is the remote board number). Access: Instant. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.1.6.7 | Unsigned32 (0..2147483647) | read-write | current |
| acSS7RedundancyKeepAliveWindow OBJECT-TYPE Defines redundancy X-link keep-alive tolerance window. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveWindow | 1.3.6.1.4.1.5003.9.10.12.1.6.8 | Unsigned32 (1..15) | read-write | current |
| acSS7RedundancyKeepAliveInterval OBJECT-TYPE Defines redundancy X-link keep-alive interval in secs. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). 0 = no keep-alive mechanism is activated. . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveInterval | 1.3.6.1.4.1.5003.9.10.12.1.6.9 | Unsigned32 (0..100) | read-write | current |
| acSS7RedundantSNTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.6.21 | not-accessible | current | |
| acSS7RedundantSNEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1 | not-accessible | current | |
| acSS7RedundantSNBoardIndex OBJECT-TYPE First index for a line: board number. AC INI-Param: SS7_RDCYSN_BOARD_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.1 | Unsigned32 (1..4) | not-accessible | current |
| acSS7RedundantSNIndex OBJECT-TYPE Second index for a line: SN number in the board. AC INI-Param: SS7_RDCYSN_SN_INDEX | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acSS7RedundantSNRowStatus OBJECT-TYPE ROWSTATUS field for line. AC INI-Param: SS7_RDCYSN_ROWSTATUS | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.3 | RowStatus | read-create | current |
| acSS7RedundantSNAction OBJECT-TYPE Management field for ACTION. AC INI-Param: SS7_RDCYSN_ACTION | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.4 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7RedundantSNActionRes OBJECT-TYPE Management field for ACTION RESULT. AC INI-Param: SS7_RDCYSN_ACTIONRES | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.5 | Unsigned32 (0..2147483647) | read-only | current |
| acSS7RedundantSNBoardIp OBJECT-TYPE IP address of the board. Access: Online. AC INI-Param: SS7_RDCYSN_BOARD_IP | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.6 | IpAddress | read-create | current |
| acSS7RedundantSNOPC OBJECT-TYPE Internal point-code of the SN (Signaling Node). Access: Online. AC INI-Param: SS7_RDCYSN_OPC | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.7 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7RedundantSNALCAPOPC OBJECT-TYPE Internal point-code of ALCAP instance on a given board. Access: Online. AC INI-Param: SS7_RDCYSN_ALCAP_OPC | 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.8 | Unsigned32 (0..2147483647) | read-create | current |
| acSS7Status OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.2 | |||
| acSS7Constants OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.12.2.1 | |||
| acSS7ConstantsNumberOfNodes OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.1 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfLinks OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.2 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfLinkSetsPerSN OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.3 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfLinksPerLinkSet OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.4 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfRouteSetsPerSN OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.5 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfRoutesPerRouteSets OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.6 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfNodeTimerSets OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.7 | Unsigned32 (0..1000) | read-only | current |
| acSS7ConstantsNumberOfLinkSetTimerSets OBJECT-TYPE AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.12.2.1.8 | Unsigned32 (0..1000) | read-only | current |