AC-PM-SS7-MIB
- Registered at
- 1.3.6.1.4.1.5003.10.13
- Last updated
- 2009-09-23 18:11
- Organization
- AudioCodes Ltd
- Namespace
- audiocodes
- Source file
AC-PM-SS7-MIB- Digest
sha256:f1d823123d8a879810e7704d4ee0c3658ce81bcee8c1daaa0ef3770d3d8b9d3a
Description
The AC-PM-SS7 MIB offers performance monitoring For the SS7 related elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-SS7 MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
Contact
Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com
Imports
| From | Symbols |
|---|---|
| AUDIOCODES-TYPES-MIB | acBoardMibs, acGeneric, acPerformance, acProducts, acRegistrations, audioCodes |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
AC-PM-SS7-MIB AUDIOCODES-TYPES-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| acPMSS7Configuration OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.1 | |||
| acPMSS7ConfigurationPeriodLength OBJECT-TYPE Length of monitoring intervals for entire MIB. Time is in minutes. Access: Online. | 1.3.6.1.4.1.5003.10.13.1.1 | Unsigned32 (0..894780) | read-write | current |
| acPMSS7ConfigurationResetTotalCounters OBJECT-TYPE Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Access: Online. | 1.3.6.1.4.1.5003.10.13.1.2 | INTEGER {resetCountersDone(1), resetTotalCounters(2)} | read-write | current |
| acPMSS7Data OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.2 | |||
| acPMSS7DataTimeFromStartOfInterval OBJECT-TYPE The time in seconds since the start of the current interval. MIB specific. | 1.3.6.1.4.1.5003.10.13.2.1 | Unsigned32 (0..2147483647) | read-only | current |
| acPMSS7Links OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.2.31 | |||
| acPMSS7TxMSUTable OBJECT-TYPE Number of transmitted MSU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.1 | not-accessible | current | |
| acPMSS7TxMSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.1.1 | not-accessible | current | |
| acPMSS7TxMSULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.1.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7TxMSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.1.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.1.1.3 | Counter32 | read-only | current |
| acPMSS7TxMSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.1.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxMSUTable OBJECT-TYPE Number of received MSU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.2 | not-accessible | current | |
| acPMSS7RxMSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.2.1 | not-accessible | current | |
| acPMSS7RxMSULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.2.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7RxMSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.2.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.2.1.3 | Counter32 | read-only | current |
| acPMSS7RxMSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.2.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxLSSUTable OBJECT-TYPE Number of transmitted LSSU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.3 | not-accessible | current | |
| acPMSS7TxLSSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.3.1 | not-accessible | current | |
| acPMSS7TxLSSULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.3.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7TxLSSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.3.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxLSSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.3.1.3 | Counter32 | read-only | current |
| acPMSS7TxLSSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.3.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxLSSUTable OBJECT-TYPE Number of received LSSU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.4 | not-accessible | current | |
| acPMSS7RxLSSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.4.1 | not-accessible | current | |
| acPMSS7RxLSSULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.4.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7RxLSSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.4.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxLSSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.4.1.3 | Counter32 | read-only | current |
| acPMSS7RxLSSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.4.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxFISUTable OBJECT-TYPE Number of transmitted FISU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.5 | not-accessible | current | |
| acPMSS7TxFISUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.5.1 | not-accessible | current | |
| acPMSS7TxFISULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.5.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7TxFISUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.5.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxFISUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.5.1.3 | Counter32 | read-only | current |
| acPMSS7TxFISUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.5.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxFISUTable OBJECT-TYPE Number of received FISU's per SS7 link. | 1.3.6.1.4.1.5003.10.13.2.31.6 | not-accessible | current | |
| acPMSS7RxFISUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.6.1 | not-accessible | current | |
| acPMSS7RxFISULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.6.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7RxFISUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.6.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxFISUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.6.1.3 | Counter32 | read-only | current |
| acPMSS7RxFISUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.6.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxSignalUnitsTable OBJECT-TYPE Number of transmitted Signaling units per SS7 link | 1.3.6.1.4.1.5003.10.13.2.31.7 | not-accessible | current | |
| acPMSS7TxSignalUnitsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.7.1 | not-accessible | current | |
| acPMSS7TxSignalUnitsLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.7.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7TxSignalUnitsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.7.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxSignalUnitsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.7.1.3 | Counter32 | read-only | current |
| acPMSS7TxSignalUnitsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.7.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxSignalUnitsTable OBJECT-TYPE Number of received Signaling units per SS7 link | 1.3.6.1.4.1.5003.10.13.2.31.8 | not-accessible | current | |
| acPMSS7RxSignalUnitsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.8.1 | not-accessible | current | |
| acPMSS7RxSignalUnitsLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.8.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7RxSignalUnitsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.8.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxSignalUnitsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.8.1.3 | Counter32 | read-only | current |
| acPMSS7RxSignalUnitsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.8.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxOctetsTable OBJECT-TYPE Number of transmitted Octets per SS7 link - Q.752 3.1 | 1.3.6.1.4.1.5003.10.13.2.31.9 | not-accessible | current | |
| acPMSS7TxOctetsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.9.1 | not-accessible | current | |
| acPMSS7TxOctetsLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.9.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7TxOctetsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.9.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxOctetsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.9.1.3 | Counter32 | read-only | current |
| acPMSS7TxOctetsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.9.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxOctetsTable OBJECT-TYPE Number of received Octets per SS7 link - Q.752 3.4 | 1.3.6.1.4.1.5003.10.13.2.31.10 | not-accessible | current | |
| acPMSS7RxOctetsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.10.1 | not-accessible | current | |
| acPMSS7RxOctetsLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.10.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7RxOctetsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.10.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxOctetsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.10.1.3 | Counter32 | read-only | current |
| acPMSS7RxOctetsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.10.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2NoAckRxTable OBJECT-TYPE Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9 | 1.3.6.1.4.1.5003.10.13.2.31.11 | not-accessible | current | |
| acPMSS7MTP2NoAckRxEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.11.1 | not-accessible | current | |
| acPMSS7MTP2NoAckRxLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.11.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2NoAckRxInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.11.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2NoAckRxVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.11.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2NoAckRxTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.11.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7DiscMSUTable OBJECT-TYPE MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10 | 1.3.6.1.4.1.5003.10.13.2.31.12 | not-accessible | current | |
| acPMSS7DiscMSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.12.1 | not-accessible | current | |
| acPMSS7DiscMSULink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.12.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7DiscMSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.12.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7DiscMSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.12.1.3 | Counter32 | read-only | current |
| acPMSS7DiscMSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.31.12.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7InServiceTable OBJECT-TYPE Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1 | 1.3.6.1.4.1.5003.10.13.2.31.13 | not-accessible | current | |
| acPMSS7InServiceEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.13.1 | not-accessible | current | |
| acPMSS7InServiceLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.13.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7InServiceInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.13.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7InServiceVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.13.1.3 | Gauge32 | read-only | current |
| acPMSS7InServiceTimeAboveHighThreshold OBJECT-TYPE Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'In Service'. | 1.3.6.1.4.1.5003.10.13.2.31.13.1.4 | Integer32 (-1..100) | read-only | current |
| acPMSS7InServiceTimeBetweenThresholds OBJECT-TYPE Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'In Service'. | 1.3.6.1.4.1.5003.10.13.2.31.13.1.5 | Integer32 (-1..100) | read-only | current |
| acPMSS7OutOfServiceTable OBJECT-TYPE Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1 | 1.3.6.1.4.1.5003.10.13.2.31.14 | not-accessible | current | |
| acPMSS7OutOfServiceEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.31.14.1 | not-accessible | current | |
| acPMSS7OutOfServiceLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.31.14.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7OutOfServiceInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.31.14.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7OutOfServiceVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.31.14.1.3 | Gauge32 | read-only | current |
| acPMSS7OutOfServiceTimeAboveHighThreshold OBJECT-TYPE Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. | 1.3.6.1.4.1.5003.10.13.2.31.14.1.4 | Integer32 (-1..100) | read-only | current |
| acPMSS7OutOfServiceTimeBetweenThresholds OBJECT-TYPE Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. | 1.3.6.1.4.1.5003.10.13.2.31.14.1.5 | Integer32 (-1..100) | read-only | current |
| acPMSS7LinkSets OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.2.41 | |||
| acPMSS7SN0LSOutOfServiceTable OBJECT-TYPE Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2 | 1.3.6.1.4.1.5003.10.13.2.41.1 | not-accessible | current | |
| acPMSS7SN0LSOutOfServiceEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.41.1.1 | not-accessible | current | |
| acPMSS7SN0LSOutOfServiceLinkSet OBJECT-TYPE Link Set number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.41.1.1.1 | Unsigned32 (0..31) | not-accessible | current |
| acPMSS7SN0LSOutOfServiceInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.41.1.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7SN0LSOutOfServiceVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.41.1.1.3 | Gauge32 | read-only | current |
| acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. | 1.3.6.1.4.1.5003.10.13.2.41.1.1.4 | Integer32 (-1..100) | read-only | current |
| acPMSS7SN0LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. | 1.3.6.1.4.1.5003.10.13.2.41.1.1.5 | Integer32 (-1..100) | read-only | current |
| acPMSS7SN1LSOutOfServiceTable OBJECT-TYPE Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2 | 1.3.6.1.4.1.5003.10.13.2.41.2 | not-accessible | current | |
| acPMSS7SN1LSOutOfServiceEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.41.2.1 | not-accessible | current | |
| acPMSS7SN1LSOutOfServiceLinkSet OBJECT-TYPE Link Set number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.41.2.1.1 | Unsigned32 (0..31) | not-accessible | current |
| acPMSS7SN1LSOutOfServiceInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.41.2.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7SN1LSOutOfServiceVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.41.2.1.3 | Gauge32 | read-only | current |
| acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'. | 1.3.6.1.4.1.5003.10.13.2.41.2.1.4 | Integer32 (-1..100) | read-only | current |
| acPMSS7SN1LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'. | 1.3.6.1.4.1.5003.10.13.2.41.2.1.5 | Integer32 (-1..100) | read-only | current |
| acPMSS7SignalingNodes OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.2.51 | |||
| acPMSS7TxMTP3OctetsTable OBJECT-TYPE Number of transmitted MTP3 octets per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.1 | not-accessible | current | |
| acPMSS7TxMTP3OctetsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.1.1 | not-accessible | current | |
| acPMSS7TxMTP3OctetsSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.1.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3OctetsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.1.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3OctetsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.1.1.3 | Counter32 | read-only | current |
| acPMSS7TxMTP3OctetsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.1.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxMTP3OctetsTable OBJECT-TYPE Number of received MTP3 octets per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.2 | not-accessible | current | |
| acPMSS7RxMTP3OctetsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.2.1 | not-accessible | current | |
| acPMSS7RxMTP3OctetsSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.2.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3OctetsInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.2.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3OctetsVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.2.1.3 | Counter32 | read-only | current |
| acPMSS7RxMTP3OctetsTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.2.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxMTP3MSUTable OBJECT-TYPE Number of transmitted MTP3 MSU's per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.3 | not-accessible | current | |
| acPMSS7TxMTP3MSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.3.1 | not-accessible | current | |
| acPMSS7TxMTP3MSUSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.3.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3MSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.3.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3MSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.3.1.3 | Counter32 | read-only | current |
| acPMSS7TxMTP3MSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.3.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxMTP3MSUTable OBJECT-TYPE Number of received MTP3 MSU's per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.4 | not-accessible | current | |
| acPMSS7RxMTP3MSUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.4.1 | not-accessible | current | |
| acPMSS7RxMTP3MSUSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.4.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3MSUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.4.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3MSUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.4.1.3 | Counter32 | read-only | current |
| acPMSS7RxMTP3MSUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.4.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7TxMTP3UPUTable OBJECT-TYPE Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.5 | not-accessible | current | |
| acPMSS7TxMTP3UPUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.5.1 | not-accessible | current | |
| acPMSS7TxMTP3UPUSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.5.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3UPUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.5.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7TxMTP3UPUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.5.1.3 | Counter32 | read-only | current |
| acPMSS7TxMTP3UPUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.5.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxMTP3UPUTable OBJECT-TYPE Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.6 | not-accessible | current | |
| acPMSS7RxMTP3UPUEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.6.1 | not-accessible | current | |
| acPMSS7RxMTP3UPUSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.6.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3UPUInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.6.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3UPUVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.6.1.3 | Counter32 | read-only | current |
| acPMSS7RxMTP3UPUTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.6.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP3MSUDiscardedTable OBJECT-TYPE Number of discarded MTP3 MSU's per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.7 | not-accessible | current | |
| acPMSS7MTP3MSUDiscardedEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.7.1 | not-accessible | current | |
| acPMSS7MTP3MSUDiscardedSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.7.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP3MSUDiscardedInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.7.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP3MSUDiscardedVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.7.1.3 | Counter32 | read-only | current |
| acPMSS7MTP3MSUDiscardedTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.7.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP3MSUDiscardedRtDataErrTable OBJECT-TYPE Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5 | 1.3.6.1.4.1.5003.10.13.2.51.8 | not-accessible | current | |
| acPMSS7MTP3MSUDiscardedRtDataErrEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.8.1 | not-accessible | current | |
| acPMSS7MTP3MSUDiscardedRtDataErrSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.8.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP3MSUDiscardedRtDataErrInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.8.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP3MSUDiscardedRtDataErrVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.8.1.3 | Counter32 | read-only | current |
| acPMSS7MTP3MSUDiscardedRtDataErrTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.8.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7RxMTP3TFCMsgTable OBJECT-TYPE Number of MTP3 TFC messages received per SS7 MTP3 node | 1.3.6.1.4.1.5003.10.13.2.51.9 | not-accessible | current | |
| acPMSS7RxMTP3TFCMsgEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.51.9.1 | not-accessible | current | |
| acPMSS7RxMTP3TFCMsgSN OBJECT-TYPE SN number. 0 is the first SN. | 1.3.6.1.4.1.5003.10.13.2.51.9.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3TFCMsgInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.51.9.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7RxMTP3TFCMsgVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.51.9.1.3 | Counter32 | read-only | current |
| acPMSS7RxMTP3TFCMsgTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.51.9.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MPT2Timers OBJECT-IDENTITY | 1.3.6.1.4.1.5003.10.13.2.61 | |||
| acPMSS7MTP2T1ExpiryTable OBJECT-TYPE Number of MTP2 T1 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.1 | not-accessible | current | |
| acPMSS7MTP2T1ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.1.1 | not-accessible | current | |
| acPMSS7MTP2T1ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.1.1.1 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T1ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.1.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T1ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.1.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T1ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.1.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T2ExpiryTable OBJECT-TYPE Number of MTP2 T2 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.2 | not-accessible | current | |
| acPMSS7MTP2T2ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.2.1 | not-accessible | current | |
| acPMSS7MTP2T2ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.2.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T2ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.2.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T2ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.2.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T2ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.2.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T3ExpiryTable OBJECT-TYPE Number of MTP2 T3 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.3 | not-accessible | current | |
| acPMSS7MTP2T3ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.3.1 | not-accessible | current | |
| acPMSS7MTP2T3ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.3.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T3ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.3.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T3ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.3.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T3ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.3.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T4ExpiryTable OBJECT-TYPE Number of MTP2 T4 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.4 | not-accessible | current | |
| acPMSS7MTP2T4ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.4.1 | not-accessible | current | |
| acPMSS7MTP2T4ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.4.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T4ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.4.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T4ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.4.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T4ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.4.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T5ExpiryTable OBJECT-TYPE Number of MTP2 T5 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.5 | not-accessible | current | |
| acPMSS7MTP2T5ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.5.1 | not-accessible | current | |
| acPMSS7MTP2T5ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.5.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T5ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.5.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T5ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.5.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T5ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.5.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T6ExpiryTable OBJECT-TYPE Number of MTP2 T6 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.6 | not-accessible | current | |
| acPMSS7MTP2T6ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.6.1 | not-accessible | current | |
| acPMSS7MTP2T6ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.6.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T6ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.6.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T6ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.6.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T6ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.6.1.4 | Integer32 (-1..2147483647) | read-only | current |
| acPMSS7MTP2T7ExpiryTable OBJECT-TYPE Number of MTP2 T7 expiry per SS7 link | 1.3.6.1.4.1.5003.10.13.2.61.7 | not-accessible | current | |
| acPMSS7MTP2T7ExpiryEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.10.13.2.61.7.1 | not-accessible | current | |
| acPMSS7MTP2T7ExpiryLink OBJECT-TYPE Link number. 0 is the first link. | 1.3.6.1.4.1.5003.10.13.2.61.7.1.1 | Unsigned32 (0..63) | not-accessible | current |
| acPMSS7MTP2T7ExpiryInterval OBJECT-TYPE Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last. | 1.3.6.1.4.1.5003.10.13.2.61.7.1.2 | Unsigned32 (0..2) | not-accessible | current |
| acPMSS7MTP2T7ExpiryVal OBJECT-TYPE Value of gauge or counter. | 1.3.6.1.4.1.5003.10.13.2.61.7.1.3 | Counter32 | read-only | current |
| acPMSS7MTP2T7ExpiryTotal OBJECT-TYPE Total since last reset. | 1.3.6.1.4.1.5003.10.13.2.61.7.1.4 | Integer32 (-1..2147483647) | read-only | current |