MIBs Depot

AC-ANALOG-MIB

Registered at
1.3.6.1.4.1.5003.9.10.8
Last updated
2012-07-26 04:46
Organization
AudioCodes Ltd
Namespace
audiocodes
Source file
AC-ANALOG-MIB
Digest
sha256:032d564d18f75611eab1fe11062ecd8da10833603eee5af14adb0263566fd291

Contact

Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com

Imports

FromSymbols
AUDIOCODES-TYPES-MIBacBoardMibs, acGeneric, acProducts, acRegistrations, audioCodes
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, TAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

AC-ANALOG-MIB
AUDIOCODES-TYPES-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
acAnalogConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1
acAnalogConfig
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.1
acAnalogMisc
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.1.1
acAnalogMiscCurrentDisconnectDuration
OBJECT-TYPE
Defines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration
1.3.6.1.4.1.5003.9.10.8.1.1.1.1Unsigned32 (200..1500)read-writecurrent
acAnalogMiscFlashHookPeriod
OBJECT-TYPE
Defines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set ‘FlashHookPeriod’ to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIOD
1.3.6.1.4.1.5003.9.10.8.1.1.1.2Unsigned32 (25..3000)read-writecurrent
acAnalogMiscGroundKeyDetection
OBJECT-TYPE
Enables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection
1.3.6.1.4.1.5003.9.10.8.1.1.1.3INTEGER {disable(0), enable(1)}read-writecurrent
acAuxiliaryFiles
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.1.2
acAuxiliaryFilesFxsCoefficients
OBJECT-TYPE
Defines the FXS loop coefficient filename. Max. 47 characters. AC INI-Param: FXSCOEFFILENAME
1.3.6.1.4.1.5003.9.10.8.1.1.2.1SnmpAdminString (SIZE(0..47))read-onlycurrent
acAuxiliaryFilesFxoCoefficients
OBJECT-TYPE
Defines the FXO loop coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME
1.3.6.1.4.1.5003.9.10.8.1.1.2.2SnmpAdminString (SIZE(0..47))read-onlycurrent
acAnalogFxoConfig
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.2
acAnalogFxo
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.2.1
acAnalogFxoFarEndDisconnectType
OBJECT-TYPE
This parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPE
1.3.6.1.4.1.5003.9.10.8.1.2.1.1Unsigned32 (0..128)read-writecurrent
acAnalogFxoCountryCoefficients
OBJECT-TYPE
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.2.1.2INTEGER {europe(66), unitedStates(70)}read-writecurrent
acAnalogFxoDCRemover
OBJECT-TYPE
Determines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemover
1.3.6.1.4.1.5003.9.10.8.1.2.1.3INTEGER {disable(0), enable(1)}read-writecurrent
acAnalogFxoDefaultLinePolarityState
OBJECT-TYPE
Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts. Access: Offline. AC INI-Param: SetDefaultLinePolarityState
1.3.6.1.4.1.5003.9.10.8.1.2.1.4INTEGER {positive-polarity(0), negative-polarity(1), polarity-auto-detect(2)}read-writecurrent
acAnalogFxoTxGainControl
OBJECT-TYPE
Sets gain\attenuation of the FXO Tx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXOTxGainControl
1.3.6.1.4.1.5003.9.10.8.1.2.1.5Integer32 (-15..12)read-writecurrent
acAnalogFxoRxGainControl
OBJECT-TYPE
Sets gain\attenuation of the FXO Rx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXORxGainControl
1.3.6.1.4.1.5003.9.10.8.1.2.1.6Integer32 (-15..12)read-writecurrent
acAnalogFxoFarEndDisconnectToneTable
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.1.2.1.21not-accessiblecurrent
acAnalogFxoFarEndDisconnectToneEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1not-accessiblecurrent
acAnalogFxoFarEndDisconnectToneRowStatus
OBJECT-TYPE
Far End Disconnect table row-status. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1Unsigned32 (1)read-writecurrent
acAnalogFxoFarEndDisconnectToneAction
OBJECT-TYPE
Far End Disconnect table action. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2Unsigned32 (0)read-writecurrent
acAnalogFxoFarEndDisconnectToneActionResult
OBJECT-TYPE
Far End Disconnect table result. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3Unsigned32 (0)read-onlycurrent
acAnalogFxoFarEndDisconnectToneIndex
OBJECT-TYPE
Index for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4Unsigned32 (0..4)read-onlycurrent
acAnalogFxoFarEndDisconnectToneType
OBJECT-TYPE
Defines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPE
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5INTEGER {acNullTone(0), acDialTone(1), acRingingTone(2), acBusyTone(3), acCongestionTone(4), acSpecialInfoTone(5), acWarningTone(6), acReorderTone(7), acConfirmationTone(8), acWaitingTone(9), acCallProgressCo1Tone(10), acCallProgressCo2Tone(11), acOldMilliwattTone(12), acNewMilliwattTone(13), acMessageWaitingIndicator(14), acStutterDialTone(15), acStutterOffHookWarningTone(16), acWaitingTone1(17), acComfortTone(18), acNAKTone(19), acVacantNumberTone(20), acSpecialConditionTone(21), acDialTone2(22), acOnHoldTone(23), acCallTransferDialTone(24), acCallForwardTone(25), acCreditCardServiceTone(26), acSpecialRecallDialTone(27), acAlertingTone(28), acNetworkCongestionTone(29), acWaitingTone2(30), acWaitingTone3(31), acWaitingTone4(32), acConfEnterTone(33), acConfExitTone(34), acConfLockTone(35), acConfUnlockTone(36), acConfTimeLimitTone(37), acPayphoneRecognitionTone(38), acCallerWaitingTone(39), acCNGFaxTone(40), acPrecConfNotifyType(41), acPresConfNotifyType(42), acPrecPreemptType(43), acPrecRTType(44), acR15reqOfANItone(45), acCo1Tone(200), acCo2Tone(201), acPlayRecordBeepTone(202), acTrunkTestingTestProgressTone(203), acTrunkTestingTestTone(204), acTrunkTestingGuardTone(205), acFSKTrunkTestingTone(206), acGeneralTrunkTestingTone1(207), acGeneralTrunkTestingTone2(208), acGeneralTrunkTestingTone3(209), acSpecialInfoToneFirst(210), acSpecialInfoToneSecond(211), acSpecialInfoToneThird(212), acTTYTone(213), acTT904ContinuityTone(214), acTTMilliwattLossMeasureTone(215), acCarrierDialTone(216), acCarrierAnswerTone(217), acCarrierChargingTone(218), acLongDistanceIndicatorTone(219), acSTUModemFirstTone(298), acSTUModemSecondTone(299)}read-writecurrent
acAnalogFxsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.3
acAnalogFxs
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.3.1
acAnalogFxsPolarityReversalType
OBJECT-TYPE
Sets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPE
1.3.6.1.4.1.5003.9.10.8.1.3.1.1INTEGER {soft(0), hard(1)}read-writecurrent
acAnalogFxsMeteringType
OBJECT-TYPE
Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE
1.3.6.1.4.1.5003.9.10.8.1.3.1.2INTEGER {mt12kHz(0), mt16kHz(1), mtPolarityReversal(2)}read-writecurrent
acAnalogFxsLifeLineType
OBJECT-TYPE
Defines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPE
1.3.6.1.4.1.5003.9.10.8.1.3.1.3INTEGER {acLifeLineType-Hardware-Only(0), acLifeLineTypeHardware-And-Link-Detection(1), acLifeLineType-Hardware-And-Link-And-Network-Detection(2)}read-writecurrent
acAnalogFxsMinFlashHookTime
OBJECT-TYPE
Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME
1.3.6.1.4.1.5003.9.10.8.1.3.1.4Unsigned32 (25..300)read-writecurrent
acAnalogFxsCallerIDTimingMode
OBJECT-TYPE
Defines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODE
1.3.6.1.4.1.5003.9.10.8.1.3.1.5INTEGER {disable(0), enable(1)}read-writecurrent
acAnalogFxsBellcoreCallerIDTypeOneSubStandard
OBJECT-TYPE
Selects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandard
1.3.6.1.4.1.5003.9.10.8.1.3.1.6INTEGER {bellcore-Between-Rings(0), bellcore-Not-Ring-Related(1), bellcore-Before-Ring-RP-AS(2)}read-writecurrent
acAnalogFxsETSICallerIDTypeOneSubStandard
OBJECT-TYPE
Selects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandard
1.3.6.1.4.1.5003.9.10.8.1.3.1.7INTEGER {eTSI-Between-Rings(0), eTSI-Before-Ring-DT-AS(1), eTSI-Before-Ring-RP-AS(2), eTSI-Before-Ring-LR-DT-AS(3), eTSI-Not-Ring-Related-DT-AS(4), eTSI-Not-Ring-Related-RP-AS(5), eTSI-Not-Ring-Related-LR-DT-AS(6)}read-writecurrent
acAnalogFxsETSIVMWITypeOneStandard
OBJECT-TYPE
Selects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandard
1.3.6.1.4.1.5003.9.10.8.1.3.1.8INTEGER {eTSI-VMWI-Between-Rings(0), eTSI-VMWI-Before-Ring-DT-AS(1), eTSI-VMWI-Before-Ring-RP-AS(2), eTSI-VMWI-Before-Ring-LR-DT-AS(3), eTSI-VMWI-Not-Ring-Related-DT-AS(4), eTSI-VMWI-Not-Ring-Related-RP-AS(5), eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)}read-writecurrent
acAnalogFxsBellcoreVMWITypeOneStandard
OBJECT-TYPE
Use this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard
1.3.6.1.4.1.5003.9.10.8.1.3.1.9INTEGER {bellcore-VMWI-Between-Rings(0), bellcore-VMWI-Not-Ring-Related(1)}read-writecurrent
acAnalogFxsDisableAutoCalibration
OBJECT-TYPE
Determines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibration
1.3.6.1.4.1.5003.9.10.8.1.3.1.10Unsigned32read-writecurrent
acAnalogFxsExternalLifeLinePorts
OBJECT-TYPE
Set the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePorts
1.3.6.1.4.1.5003.9.10.8.1.3.1.11Unsigned32 (0..24)read-writecurrent
acAnalogFxsCountryCoefficients
OBJECT-TYPE
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.3.1.12INTEGER {europe(66), unitedStates(70)}read-writecurrent
acAnalogFxsTTXVoltageLevel
OBJECT-TYPE
Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevel
1.3.6.1.4.1.5003.9.10.8.1.3.1.13INTEGER {notAvailable(-1), ttxVoltageLevel0V(0), ttxVoltageLevel05(1), ttxVoltageLevel1V(2)}read-writecurrent
acAnalogEMConfig
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.4
acAnalogEM
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.1.4.1
acAnalogEMVoiceType
OBJECT-TYPE
E&M Voice Configuration Type 2 or 4 wire. Access: Offline. AC INI-Param: EnMVoiceType
1.3.6.1.4.1.5003.9.10.8.1.4.1.1INTEGER {twoWire(0), fourWire(1)}read-writecurrent
acAnalogEMInterfaceType
OBJECT-TYPE
E&M Signaling Type - Trunking or Signaling. Access: Offline. AC INI-Param: EnMSystemType
1.3.6.1.4.1.5003.9.10.8.1.4.1.2INTEGER {signaling(0), trunking(1)}read-writecurrent
acAnalogEMSignalingType
OBJECT-TYPE
Set E&M standatd signaling types are described in TIA/EIA-464C. Access: Offline. AC INI-Param: EnMSignalingType
1.3.6.1.4.1.5003.9.10.8.1.4.1.3Unsigned32 (1..5)read-writecurrent
acAnalogEMPortRXGain
OBJECT-TYPE
Rx Gain. Access: Offline. AC INI-Param: EnMPortRXGain
1.3.6.1.4.1.5003.9.10.8.1.4.1.4INTEGER {disable(0), enable(1)}read-writecurrent
acAnalogEMPortTXGain
OBJECT-TYPE
Tx Gain. Access: Offline. AC INI-Param: EnMPortTXGain
1.3.6.1.4.1.5003.9.10.8.1.4.1.5INTEGER {disable(0), enable(1)}read-writecurrent
acAnalogEMCountryCoefficients
OBJECT-TYPE
E&M Country Coefficients. Access: Offline. AC INI-Param: EnMCountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.4.1.6INTEGER {unitedStates(0), europe(1)}read-writecurrent
acAnalogEMHookDebounceTiming
OBJECT-TYPE
Sets the on E&M hook detection debounce timing. Access: Offline. AC INI-Param: EnMhookDebounceTiming
1.3.6.1.4.1.5003.9.10.8.1.4.1.7Unsigned32 (30..150)read-writecurrent
acAnalogEMOffHookGlareEnable
OBJECT-TYPE
Protect the EnM port from Rx and Tx hook collision. Access: Offline. AC INI-Param: EnMOffHookGlareEnable
1.3.6.1.4.1.5003.9.10.8.1.4.1.8INTEGER {disable(0), enable(1)}read-writecurrent
acAnalogStatus
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.2
acAnalogStatusMisc
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.2.1
acAnalogStatusMiscFxsOrFxo
OBJECT-TYPE
Board is Fxs,Fxo, FXS_FXO or E&M. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.1.1INTEGER {fXO(0), fXS(1), eANDm(2), fXOandFXS(3), fXOandFXSandEM(5), fXOandEM(6), fXSandEM(7)}read-onlycurrent
acAnalogStatusMiscBoardTemperature
OBJECT-TYPE
Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.1.2Unsigned32 (0..100)read-onlycurrent
acAnalogStatusMiscAnalogChannelsCount
OBJECT-TYPE
Number of the Analog channels in the board. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.1.3Unsigned32 (0..5000)read-onlycurrent
acAnalogFxsFxo
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.2.20
acAnalogFxsFxoTable
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.2.20.1not-accessiblecurrent
acAnalogFxsFxoEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.2.20.1.1not-accessiblecurrent
acAnalogFxsFxoIndex
OBJECT-TYPE
Index for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1Unsigned32 (0..24)not-accessiblecurrent
acAnalogFxsFxoType
OBJECT-TYPE
Line is Fxs, Fxo or E&M. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2INTEGER {fXO(0), fXS(1), eM(2)}read-onlycurrent
acAnalogFxsFxoChipRevNum
OBJECT-TYPE
Fxs/Fxo's Chip revision number. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3Unsigned32 (0..2147483647)read-onlycurrent
acAnalogFxsFxoHookState
OBJECT-TYPE
The hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4INTEGER {onHookState(1), offHookState(2)}read-onlycurrent
acAnalogLegs
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.2.21
acAnalogLegsTable
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.2.21.1not-accessiblecurrent
acAnalogLegsEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.2.21.1.1not-accessiblecurrent
acAnalogLegsLegIndex
OBJECT-TYPE
Decribes The Digital EndPoint In A Call. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1Unsigned32 (0..5000)not-accessiblecurrent
acAnalogLegsCallIndex
OBJECT-TYPE
Decribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2Unsigned32 (0..5000)read-onlycurrent
acAnalogLegsAnalogType
OBJECT-TYPE
Describs whether the board is FXS or FXO. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3INTEGER {fxs(1), fxo(2)}read-onlycurrent
acAnalogLegsEchoCanceller
OBJECT-TYPE
Enables or Disables the Echo Canceller. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4INTEGER {disable(0), enable(1)}read-onlycurrent
acAnalogLegsHighPassFilter
OBJECT-TYPE
Enables or Disables theHigh Pass Filter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5INTEGER {disable(0), enable(1)}read-onlycurrent
acAnalogLegsDTMFDetection
OBJECT-TYPE
Enables or Disables the DTMF Detection. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6INTEGER {disable(0), enable(1)}read-onlycurrent
acAnalogLegsVoiceVolume
OBJECT-TYPE
Describs the volume of the voice in dB. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7Unsigned32 (0..20000)read-onlycurrent
acAnalogLegsInputGain
OBJECT-TYPE
Describes the Input Gain on the leg in dB. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8Unsigned32 (0..20000)read-onlycurrent
acAnalogLegsLegName
OBJECT-TYPE
Describes the Leg Name as in the Control Protocol. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9SnmpAdminString (SIZE(0..64))read-onlycurrent
acAnalogAction
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.3
acAnalogFxoAction
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.3.1
acAnalogFxoLineTestTable
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.3.1.1not-accessiblecurrent
acAnalogFxoLineTestEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.3.1.1.1not-accessiblecurrent
acAnalogFxoLineTestIndex
OBJECT-TYPE
Index for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1Unsigned32 (0..24)not-accessiblecurrent
acAnalogFxoLineTestActivate
OBJECT-TYPE
Activate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2INTEGER {noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)}read-writecurrent
acAnalogFxoLineTestHookState
OBJECT-TYPE
The hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3INTEGER {onHookState(1), offHookState(2)}read-onlycurrent
acAnalogFxoLineTestPolarityStatus
OBJECT-TYPE
The line's polarity state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4INTEGER {normalPolarity(1), reversePolarity(2), notAvailable(3)}read-onlycurrent
acAnalogFxoLineTestLineConnectionStatus
OBJECT-TYPE
The connection's status of the line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5INTEGER {lineDisconnected(1), lineConnected(2)}read-onlycurrent
acAnalogFxoLineTestLineCurrent
OBJECT-TYPE
The line's current [ma]. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6Integer32 (-1..24)read-onlycurrent
acAnalogFxoLineTestLineVoltage
OBJECT-TYPE
The line's voltage [V]. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7Integer32 (-128..128)read-onlycurrent
acAnalogFxoLineTestRingState
OBJECT-TYPE
The Ring's State. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8INTEGER {off(1), on(2)}read-onlycurrent
acAnalogFxoLineTestLinePolarity
OBJECT-TYPE
The line's polarity state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9INTEGER {positive(1), negative(2)}read-onlycurrent
acAnalogFxoLineTestMwiState
OBJECT-TYPE
Mwi's state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10INTEGER {off(1), on(2)}read-onlycurrent
acAnalogFxoLineTestLastCurrentDisconnectDuration
OBJECT-TYPE
Last current disconnect duration in msec. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11Unsigned32 (0..2147483647)read-onlycurrent
acAnalogFxsAction
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.3.2
acAnalogFxsLineTestTable
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.3.2.1not-accessiblecurrent
acAnalogFxsLineTestEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.3.2.1.1not-accessiblecurrent
acAnalogFxsLineTestIndex
OBJECT-TYPE
Index for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1Unsigned32 (0..24)not-accessiblecurrent
acAnalogFxsLineTestActivate
OBJECT-TYPE
Activate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2INTEGER {noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)}read-writecurrent
acAnalogFxsLineTestHookState
OBJECT-TYPE
The hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3INTEGER {onHookState(1), offHookState(2)}read-onlycurrent
acAnalogFxsLineTestRingState
OBJECT-TYPE
Line's ring state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4INTEGER {offRingState(1), onRingState(2)}read-onlycurrent
acAnalogFxsLineTestPolarityStatus
OBJECT-TYPE
Line's reversal-polarity. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5INTEGER {normalPolarity(1), reversePolarity(2)}read-onlycurrent
acAnalogFxsLineTestMessageWaitingIndication
OBJECT-TYPE
Line's messgae waiting indication state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6INTEGER {noWaitingMessage(1), waitingMessage(2)}read-onlycurrent
acAnalogFxsLineTestLineCurrentReading
OBJECT-TYPE
The Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7Unsigned32 (0..3000)read-onlyobsolete
acAnalogFxsLineTestLineVoltageReading
OBJECT-TYPE
The Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8Integer32 (-6000..6000)read-onlyobsolete
acAnalogFxsLineTestAnalogVoltageReading
OBJECT-TYPE
The current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9Unsigned32 (300..340)read-onlyobsolete
acAnalogFxsLineTestRingVoltageReading
OBJECT-TYPE
The current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10Integer32 (-13000..13000)read-onlyobsolete
acAnalogFxsLineTestLongLineCurrentReading
OBJECT-TYPE
The current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11Unsigned32 (0..4000)read-onlyobsolete
acAnalogCommonAction
OBJECT-IDENTITY
1.3.6.1.4.1.5003.9.10.8.3.3
acAnalogCommonChannelTable
OBJECT-TYPE
Table for common channels operations.
1.3.6.1.4.1.5003.9.10.8.3.3.1not-accessiblecurrent
acAnalogCommonChannelEntry
OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.3.3.1.1not-accessiblecurrent
acAnalogCommonChannelIndex
OBJECT-TYPE
Index for table use, the current channel. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1Unsigned32 (0..5000)not-accessiblecurrent
acAnalogCommonChannelAction
OBJECT-TYPE
An action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2INTEGER {noAction(0), reset(1)}read-writecurrent