AC-ANALOG-MIB
- Registered at
- 1.3.6.1.4.1.5003.9.10.8
- Last updated
- 2012-07-26 04:46
- Organization
- AudioCodes Ltd
- Namespace
- audiocodes
- Source file
AC-ANALOG-MIB- Digest
sha256:032d564d18f75611eab1fe11062ecd8da10833603eee5af14adb0263566fd291
Contact
Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com
Imports
| From | Symbols |
|---|---|
| AUDIOCODES-TYPES-MIB | acBoardMibs, acGeneric, acProducts, acRegistrations, audioCodes |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
AC-ANALOG-MIB AUDIOCODES-TYPES-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| acAnalogConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1 | |||
| acAnalogConfig OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.1 | |||
| acAnalogMisc OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.1.1 | |||
| acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE Defines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration | 1.3.6.1.4.1.5003.9.10.8.1.1.1.1 | Unsigned32 (200..1500) | read-write | current |
| acAnalogMiscFlashHookPeriod OBJECT-TYPE Defines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set ‘FlashHookPeriod’ to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIOD | 1.3.6.1.4.1.5003.9.10.8.1.1.1.2 | Unsigned32 (25..3000) | read-write | current |
| acAnalogMiscGroundKeyDetection OBJECT-TYPE Enables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection | 1.3.6.1.4.1.5003.9.10.8.1.1.1.3 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAuxiliaryFiles OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.1.2 | |||
| acAuxiliaryFilesFxsCoefficients OBJECT-TYPE Defines the FXS loop coefficient filename. Max. 47 characters. AC INI-Param: FXSCOEFFILENAME | 1.3.6.1.4.1.5003.9.10.8.1.1.2.1 | SnmpAdminString (SIZE(0..47)) | read-only | current |
| acAuxiliaryFilesFxoCoefficients OBJECT-TYPE Defines the FXO loop coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME | 1.3.6.1.4.1.5003.9.10.8.1.1.2.2 | SnmpAdminString (SIZE(0..47)) | read-only | current |
| acAnalogFxoConfig OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.2 | |||
| acAnalogFxo OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.2.1 | |||
| acAnalogFxoFarEndDisconnectType OBJECT-TYPE This parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPE | 1.3.6.1.4.1.5003.9.10.8.1.2.1.1 | Unsigned32 (0..128) | read-write | current |
| acAnalogFxoCountryCoefficients OBJECT-TYPE Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients | 1.3.6.1.4.1.5003.9.10.8.1.2.1.2 | INTEGER {europe(66), unitedStates(70)} | read-write | current |
| acAnalogFxoDCRemover OBJECT-TYPE Determines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemover | 1.3.6.1.4.1.5003.9.10.8.1.2.1.3 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAnalogFxoDefaultLinePolarityState OBJECT-TYPE Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts. Access: Offline. AC INI-Param: SetDefaultLinePolarityState | 1.3.6.1.4.1.5003.9.10.8.1.2.1.4 | INTEGER {positive-polarity(0), negative-polarity(1), polarity-auto-detect(2)} | read-write | current |
| acAnalogFxoTxGainControl OBJECT-TYPE Sets gain\attenuation of the FXO Tx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXOTxGainControl | 1.3.6.1.4.1.5003.9.10.8.1.2.1.5 | Integer32 (-15..12) | read-write | current |
| acAnalogFxoRxGainControl OBJECT-TYPE Sets gain\attenuation of the FXO Rx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXORxGainControl | 1.3.6.1.4.1.5003.9.10.8.1.2.1.6 | Integer32 (-15..12) | read-write | current |
| acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21 | not-accessible | current | |
| acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1 | not-accessible | current | |
| acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE Far End Disconnect table row-status. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1 | Unsigned32 (1) | read-write | current |
| acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE Far End Disconnect table action. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2 | Unsigned32 (0) | read-write | current |
| acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE Far End Disconnect table result. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3 | Unsigned32 (0) | read-only | current |
| acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE Index for table use. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4 | Unsigned32 (0..4) | read-only | current |
| acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE Defines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPE | 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5 | INTEGER {acNullTone(0), acDialTone(1), acRingingTone(2), acBusyTone(3), acCongestionTone(4), acSpecialInfoTone(5), acWarningTone(6), acReorderTone(7), acConfirmationTone(8), acWaitingTone(9), acCallProgressCo1Tone(10), acCallProgressCo2Tone(11), acOldMilliwattTone(12), acNewMilliwattTone(13), acMessageWaitingIndicator(14), acStutterDialTone(15), acStutterOffHookWarningTone(16), acWaitingTone1(17), acComfortTone(18), acNAKTone(19), acVacantNumberTone(20), acSpecialConditionTone(21), acDialTone2(22), acOnHoldTone(23), acCallTransferDialTone(24), acCallForwardTone(25), acCreditCardServiceTone(26), acSpecialRecallDialTone(27), acAlertingTone(28), acNetworkCongestionTone(29), acWaitingTone2(30), acWaitingTone3(31), acWaitingTone4(32), acConfEnterTone(33), acConfExitTone(34), acConfLockTone(35), acConfUnlockTone(36), acConfTimeLimitTone(37), acPayphoneRecognitionTone(38), acCallerWaitingTone(39), acCNGFaxTone(40), acPrecConfNotifyType(41), acPresConfNotifyType(42), acPrecPreemptType(43), acPrecRTType(44), acR15reqOfANItone(45), acCo1Tone(200), acCo2Tone(201), acPlayRecordBeepTone(202), acTrunkTestingTestProgressTone(203), acTrunkTestingTestTone(204), acTrunkTestingGuardTone(205), acFSKTrunkTestingTone(206), acGeneralTrunkTestingTone1(207), acGeneralTrunkTestingTone2(208), acGeneralTrunkTestingTone3(209), acSpecialInfoToneFirst(210), acSpecialInfoToneSecond(211), acSpecialInfoToneThird(212), acTTYTone(213), acTT904ContinuityTone(214), acTTMilliwattLossMeasureTone(215), acCarrierDialTone(216), acCarrierAnswerTone(217), acCarrierChargingTone(218), acLongDistanceIndicatorTone(219), acSTUModemFirstTone(298), acSTUModemSecondTone(299)} | read-write | current |
| acAnalogFxsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.3 | |||
| acAnalogFxs OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.3.1 | |||
| acAnalogFxsPolarityReversalType OBJECT-TYPE Sets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPE | 1.3.6.1.4.1.5003.9.10.8.1.3.1.1 | INTEGER {soft(0), hard(1)} | read-write | current |
| acAnalogFxsMeteringType OBJECT-TYPE Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE | 1.3.6.1.4.1.5003.9.10.8.1.3.1.2 | INTEGER {mt12kHz(0), mt16kHz(1), mtPolarityReversal(2)} | read-write | current |
| acAnalogFxsLifeLineType OBJECT-TYPE Defines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPE | 1.3.6.1.4.1.5003.9.10.8.1.3.1.3 | INTEGER {acLifeLineType-Hardware-Only(0), acLifeLineTypeHardware-And-Link-Detection(1), acLifeLineType-Hardware-And-Link-And-Network-Detection(2)} | read-write | current |
| acAnalogFxsMinFlashHookTime OBJECT-TYPE Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME | 1.3.6.1.4.1.5003.9.10.8.1.3.1.4 | Unsigned32 (25..300) | read-write | current |
| acAnalogFxsCallerIDTimingMode OBJECT-TYPE Defines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODE | 1.3.6.1.4.1.5003.9.10.8.1.3.1.5 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE Selects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandard | 1.3.6.1.4.1.5003.9.10.8.1.3.1.6 | INTEGER {bellcore-Between-Rings(0), bellcore-Not-Ring-Related(1), bellcore-Before-Ring-RP-AS(2)} | read-write | current |
| acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE Selects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandard | 1.3.6.1.4.1.5003.9.10.8.1.3.1.7 | INTEGER {eTSI-Between-Rings(0), eTSI-Before-Ring-DT-AS(1), eTSI-Before-Ring-RP-AS(2), eTSI-Before-Ring-LR-DT-AS(3), eTSI-Not-Ring-Related-DT-AS(4), eTSI-Not-Ring-Related-RP-AS(5), eTSI-Not-Ring-Related-LR-DT-AS(6)} | read-write | current |
| acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE Selects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandard | 1.3.6.1.4.1.5003.9.10.8.1.3.1.8 | INTEGER {eTSI-VMWI-Between-Rings(0), eTSI-VMWI-Before-Ring-DT-AS(1), eTSI-VMWI-Before-Ring-RP-AS(2), eTSI-VMWI-Before-Ring-LR-DT-AS(3), eTSI-VMWI-Not-Ring-Related-DT-AS(4), eTSI-VMWI-Not-Ring-Related-RP-AS(5), eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)} | read-write | current |
| acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE Use this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard | 1.3.6.1.4.1.5003.9.10.8.1.3.1.9 | INTEGER {bellcore-VMWI-Between-Rings(0), bellcore-VMWI-Not-Ring-Related(1)} | read-write | current |
| acAnalogFxsDisableAutoCalibration OBJECT-TYPE Determines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibration | 1.3.6.1.4.1.5003.9.10.8.1.3.1.10 | Unsigned32 | read-write | current |
| acAnalogFxsExternalLifeLinePorts OBJECT-TYPE Set the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePorts | 1.3.6.1.4.1.5003.9.10.8.1.3.1.11 | Unsigned32 (0..24) | read-write | current |
| acAnalogFxsCountryCoefficients OBJECT-TYPE Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients | 1.3.6.1.4.1.5003.9.10.8.1.3.1.12 | INTEGER {europe(66), unitedStates(70)} | read-write | current |
| acAnalogFxsTTXVoltageLevel OBJECT-TYPE Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevel | 1.3.6.1.4.1.5003.9.10.8.1.3.1.13 | INTEGER {notAvailable(-1), ttxVoltageLevel0V(0), ttxVoltageLevel05(1), ttxVoltageLevel1V(2)} | read-write | current |
| acAnalogEMConfig OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.4 | |||
| acAnalogEM OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.1.4.1 | |||
| acAnalogEMVoiceType OBJECT-TYPE E&M Voice Configuration Type 2 or 4 wire. Access: Offline. AC INI-Param: EnMVoiceType | 1.3.6.1.4.1.5003.9.10.8.1.4.1.1 | INTEGER {twoWire(0), fourWire(1)} | read-write | current |
| acAnalogEMInterfaceType OBJECT-TYPE E&M Signaling Type - Trunking or Signaling. Access: Offline. AC INI-Param: EnMSystemType | 1.3.6.1.4.1.5003.9.10.8.1.4.1.2 | INTEGER {signaling(0), trunking(1)} | read-write | current |
| acAnalogEMSignalingType OBJECT-TYPE Set E&M standatd signaling types are described in TIA/EIA-464C. Access: Offline. AC INI-Param: EnMSignalingType | 1.3.6.1.4.1.5003.9.10.8.1.4.1.3 | Unsigned32 (1..5) | read-write | current |
| acAnalogEMPortRXGain OBJECT-TYPE Rx Gain. Access: Offline. AC INI-Param: EnMPortRXGain | 1.3.6.1.4.1.5003.9.10.8.1.4.1.4 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAnalogEMPortTXGain OBJECT-TYPE Tx Gain. Access: Offline. AC INI-Param: EnMPortTXGain | 1.3.6.1.4.1.5003.9.10.8.1.4.1.5 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAnalogEMCountryCoefficients OBJECT-TYPE E&M Country Coefficients. Access: Offline. AC INI-Param: EnMCountryCoefficients | 1.3.6.1.4.1.5003.9.10.8.1.4.1.6 | INTEGER {unitedStates(0), europe(1)} | read-write | current |
| acAnalogEMHookDebounceTiming OBJECT-TYPE Sets the on E&M hook detection debounce timing. Access: Offline. AC INI-Param: EnMhookDebounceTiming | 1.3.6.1.4.1.5003.9.10.8.1.4.1.7 | Unsigned32 (30..150) | read-write | current |
| acAnalogEMOffHookGlareEnable OBJECT-TYPE Protect the EnM port from Rx and Tx hook collision. Access: Offline. AC INI-Param: EnMOffHookGlareEnable | 1.3.6.1.4.1.5003.9.10.8.1.4.1.8 | INTEGER {disable(0), enable(1)} | read-write | current |
| acAnalogStatus OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.2 | |||
| acAnalogStatusMisc OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.2.1 | |||
| acAnalogStatusMiscFxsOrFxo OBJECT-TYPE Board is Fxs,Fxo, FXS_FXO or E&M. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.1.1 | INTEGER {fXO(0), fXS(1), eANDm(2), fXOandFXS(3), fXOandFXSandEM(5), fXOandEM(6), fXSandEM(7)} | read-only | current |
| acAnalogStatusMiscBoardTemperature OBJECT-TYPE Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.1.2 | Unsigned32 (0..100) | read-only | current |
| acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE Number of the Analog channels in the board. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.1.3 | Unsigned32 (0..5000) | read-only | current |
| acAnalogFxsFxo OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.2.20 | |||
| acAnalogFxsFxoTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.2.20.1 | not-accessible | current | |
| acAnalogFxsFxoEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.2.20.1.1 | not-accessible | current | |
| acAnalogFxsFxoIndex OBJECT-TYPE Index for table use. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1 | Unsigned32 (0..24) | not-accessible | current |
| acAnalogFxsFxoType OBJECT-TYPE Line is Fxs, Fxo or E&M. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2 | INTEGER {fXO(0), fXS(1), eM(2)} | read-only | current |
| acAnalogFxsFxoChipRevNum OBJECT-TYPE Fxs/Fxo's Chip revision number. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3 | Unsigned32 (0..2147483647) | read-only | current |
| acAnalogFxsFxoHookState OBJECT-TYPE The hook state of the analog line. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4 | INTEGER {onHookState(1), offHookState(2)} | read-only | current |
| acAnalogLegs OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.2.21 | |||
| acAnalogLegsTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.2.21.1 | not-accessible | current | |
| acAnalogLegsEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1 | not-accessible | current | |
| acAnalogLegsLegIndex OBJECT-TYPE Decribes The Digital EndPoint In A Call. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1 | Unsigned32 (0..5000) | not-accessible | current |
| acAnalogLegsCallIndex OBJECT-TYPE Decribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2 | Unsigned32 (0..5000) | read-only | current |
| acAnalogLegsAnalogType OBJECT-TYPE Describs whether the board is FXS or FXO. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3 | INTEGER {fxs(1), fxo(2)} | read-only | current |
| acAnalogLegsEchoCanceller OBJECT-TYPE Enables or Disables the Echo Canceller. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4 | INTEGER {disable(0), enable(1)} | read-only | current |
| acAnalogLegsHighPassFilter OBJECT-TYPE Enables or Disables theHigh Pass Filter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5 | INTEGER {disable(0), enable(1)} | read-only | current |
| acAnalogLegsDTMFDetection OBJECT-TYPE Enables or Disables the DTMF Detection. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6 | INTEGER {disable(0), enable(1)} | read-only | current |
| acAnalogLegsVoiceVolume OBJECT-TYPE Describs the volume of the voice in dB. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7 | Unsigned32 (0..20000) | read-only | current |
| acAnalogLegsInputGain OBJECT-TYPE Describes the Input Gain on the leg in dB. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8 | Unsigned32 (0..20000) | read-only | current |
| acAnalogLegsLegName OBJECT-TYPE Describes the Leg Name as in the Control Protocol. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9 | SnmpAdminString (SIZE(0..64)) | read-only | current |
| acAnalogAction OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.3 | |||
| acAnalogFxoAction OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.3.1 | |||
| acAnalogFxoLineTestTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.3.1.1 | not-accessible | current | |
| acAnalogFxoLineTestEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1 | not-accessible | current | |
| acAnalogFxoLineTestIndex OBJECT-TYPE Index for table use. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1 | Unsigned32 (0..24) | not-accessible | current |
| acAnalogFxoLineTestActivate OBJECT-TYPE Activate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2 | INTEGER {noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)} | read-write | current |
| acAnalogFxoLineTestHookState OBJECT-TYPE The hook state of the analog line. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3 | INTEGER {onHookState(1), offHookState(2)} | read-only | current |
| acAnalogFxoLineTestPolarityStatus OBJECT-TYPE The line's polarity state. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4 | INTEGER {normalPolarity(1), reversePolarity(2), notAvailable(3)} | read-only | current |
| acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE The connection's status of the line. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5 | INTEGER {lineDisconnected(1), lineConnected(2)} | read-only | current |
| acAnalogFxoLineTestLineCurrent OBJECT-TYPE The line's current [ma]. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6 | Integer32 (-1..24) | read-only | current |
| acAnalogFxoLineTestLineVoltage OBJECT-TYPE The line's voltage [V]. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7 | Integer32 (-128..128) | read-only | current |
| acAnalogFxoLineTestRingState OBJECT-TYPE The Ring's State. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8 | INTEGER {off(1), on(2)} | read-only | current |
| acAnalogFxoLineTestLinePolarity OBJECT-TYPE The line's polarity state. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9 | INTEGER {positive(1), negative(2)} | read-only | current |
| acAnalogFxoLineTestMwiState OBJECT-TYPE Mwi's state. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10 | INTEGER {off(1), on(2)} | read-only | current |
| acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE Last current disconnect duration in msec. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11 | Unsigned32 (0..2147483647) | read-only | current |
| acAnalogFxsAction OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.3.2 | |||
| acAnalogFxsLineTestTable OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.3.2.1 | not-accessible | current | |
| acAnalogFxsLineTestEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1 | not-accessible | current | |
| acAnalogFxsLineTestIndex OBJECT-TYPE Index for table use. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1 | Unsigned32 (0..24) | not-accessible | current |
| acAnalogFxsLineTestActivate OBJECT-TYPE Activate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2 | INTEGER {noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)} | read-write | current |
| acAnalogFxsLineTestHookState OBJECT-TYPE The hook state of the analog line. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3 | INTEGER {onHookState(1), offHookState(2)} | read-only | current |
| acAnalogFxsLineTestRingState OBJECT-TYPE Line's ring state. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4 | INTEGER {offRingState(1), onRingState(2)} | read-only | current |
| acAnalogFxsLineTestPolarityStatus OBJECT-TYPE Line's reversal-polarity. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5 | INTEGER {normalPolarity(1), reversePolarity(2)} | read-only | current |
| acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE Line's messgae waiting indication state. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6 | INTEGER {noWaitingMessage(1), waitingMessage(2)} | read-only | current |
| acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE The Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7 | Unsigned32 (0..3000) | read-only | obsolete |
| acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE The Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8 | Integer32 (-6000..6000) | read-only | obsolete |
| acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE The current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9 | Unsigned32 (300..340) | read-only | obsolete |
| acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE The current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10 | Integer32 (-13000..13000) | read-only | obsolete |
| acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE The current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11 | Unsigned32 (0..4000) | read-only | obsolete |
| acAnalogCommonAction OBJECT-IDENTITY | 1.3.6.1.4.1.5003.9.10.8.3.3 | |||
| acAnalogCommonChannelTable OBJECT-TYPE Table for common channels operations. | 1.3.6.1.4.1.5003.9.10.8.3.3.1 | not-accessible | current | |
| acAnalogCommonChannelEntry OBJECT-TYPE | 1.3.6.1.4.1.5003.9.10.8.3.3.1.1 | not-accessible | current | |
| acAnalogCommonChannelIndex OBJECT-TYPE Index for table use, the current channel. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1 | Unsigned32 (0..5000) | not-accessible | current |
| acAnalogCommonChannelAction OBJECT-TYPE An action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A | 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2 | INTEGER {noAction(0), reset(1)} | read-write | current |